Helmet Fit and Cervical Spine Motion in Collegiate Men's Lacrosse Athletes Secured to a Spine Board
Petschauer, Meredith A.; Schmitz, Randy; Gill, Diane L.
2010-01-01
Abstract Context: Proper management of cervical spine injuries in men's lacrosse players depends in part upon the ability of the helmet to immobilize the head. Objective: To determine if properly and improperly fitted lacrosse helmets provide adequate stabilization of the head in the spine-boarded athlete. Design: Crossover study. Setting: Sports medicine research laboratory. Patients or Other Participants: Eighteen healthy collegiate men's lacrosse players. Intervention(s): Participants were asked to move their heads through 3 planes of motion after being secured to a spine board under 3 helmet conditions. Main Outcome Measure(s): Change in range of motion in the cervical spine was calculated for the sagittal, frontal, and transverse planes for both head-to-thorax and helmet-to-thorax range of motion in all 3 helmet conditions (properly fitted, improperly fitted, and no helmet). Results: Head-to-thorax range of motion with the properly fitted and improperly fitted helmets was greater than in the no-helmet condition (P < .0001). In the sagittal plane, range of motion was greater with the improperly fitted helmet than with the properly fitted helmet. No difference was observed in helmet-to-thorax range of motion between properly and improperly fitted helmet conditions. Head-to-thorax range of motion was greater than helmet-to-thorax range of motion in all 3 planes (P < .0001). Conclusions: Cervical spine motion was minimized the most in the no-helmet condition, indicating that in lacrosse players, unlike football players, the helmet may need to be removed before stabilization. PMID:20446833
McGarry, Michelle H; Nguyen, Michael L; Quigley, Ryan J; Hanypsiak, Bryan; Gupta, Ranjan; Lee, Thay Q
2016-06-01
To evaluate the effect of loading the long and short heads of the biceps on glenohumeral range of motion and humeral head position. Eight cadaveric shoulders were tested in 60° abduction in the scapula and coronal plane. Muscle loading was applied based on cross-sectional area ratios. The short and long head of the biceps were loaded individually followed by combined loading. Range of motion was measured with 2.2 Nm torque, and the humeral head apex position was measured using a MicroScribe. A paired t test with Bonferroni correction was used for statistics. Long head loading decreased internal rotation in both the scapular (17.9 %) and coronal planes (5.7 %) and external rotation in the scapular plane (2.6 %) (P < 0.04). With only short head loading, maximum internal rotation was significantly increased in the scapular and coronal plane. Long head and short head loading shifted the humeral head apex posteriorly in maximum internal rotation in both planes with the long head shift being significantly greater than the short head. Long head loading also shifted the humeral apex inferiorly in internal rotation and inferiorly posteriorly in neutral rotation in the scapular plane. With the long head unloaded, there was a significant superior shift with short head loading in both planes. Loading the long head of the biceps had a much greater effect on glenohumeral range of motion and humeral head shift than the short head of the biceps; however, in the absence of long head loading, with the short head loaded, maximum internal rotation increases and the humeral head shifts superiorly, which may contribute to impingement following tenodesis of the long head of the biceps. These small changes in rotational range of motion and humeral head position with biceps tenodesis may not lead to pathologic conditions in low-demand patients; however, in throwers, biceps tenodesis may lead to increased contact pressures in late-cocking and deceleration that will likely translate to decreased performance therefore every effort should be made to preserve the biceps-labral complex.
The effect of the long head of the biceps on glenohumeral kinematics.
Youm, Thomas; ElAttrache, Neal S; Tibone, James E; McGarry, Michelle H; Lee, Thay Q
2009-01-01
The long head of the biceps has been described as a stabilizing force in the setting of glenohumeral instability. However, data are lacking on the effect of loading the long head of the biceps on glenohumeral kinematics. Six cadaveric shoulders were tested for glenohumeral rotational range of motion and translation using a custom shoulder testing system and the Microscribe 3DLX (Immersion, San Jose, CA). The path of glenohumeral articulation (PGA) was measured by calculating the humeral head center with respect to the glenoid articular surface at maximal internal rotation, 30 degrees, 60 degrees, 90 degrees, and maximal external rotation. Significant decreases in glenohumeral rotational range of motion and translation were found with 22-N biceps loading vs the unloaded group. With respect to the PGA, the humeral rotation center was shifted posterior with biceps loading at maximal internal rotation, 30 degrees, and 60 degrees of external rotation. Loading the long head of the biceps significantly affects glenohumeral rotational range of motion, translations, and kinematics.
Head Motion Modeling for Human Behavior Analysis in Dyadic Interaction
Xiao, Bo; Georgiou, Panayiotis; Baucom, Brian; Narayanan, Shrikanth S.
2015-01-01
This paper presents a computational study of head motion in human interaction, notably of its role in conveying interlocutors’ behavioral characteristics. Head motion is physically complex and carries rich information; current modeling approaches based on visual signals, however, are still limited in their ability to adequately capture these important properties. Guided by the methodology of kinesics, we propose a data driven approach to identify typical head motion patterns. The approach follows the steps of first segmenting motion events, then parametrically representing the motion by linear predictive features, and finally generalizing the motion types using Gaussian mixture models. The proposed approach is experimentally validated using video recordings of communication sessions from real couples involved in a couples therapy study. In particular we use the head motion model to classify binarized expert judgments of the interactants’ specific behavioral characteristics where entrainment in head motion is hypothesized to play a role: Acceptance, Blame, Positive, and Negative behavior. We achieve accuracies in the range of 60% to 70% for the various experimental settings and conditions. In addition, we describe a measure of motion similarity between the interaction partners based on the proposed model. We show that the relative change of head motion similarity during the interaction significantly correlates with the expert judgments of the interactants’ behavioral characteristics. These findings demonstrate the effectiveness of the proposed head motion model, and underscore the promise of analyzing human behavioral characteristics through signal processing methods. PMID:26557047
Similar range of motion and function after resurfacing large–head or standard total hip arthroplasty
2013-01-01
Background and purpose Large–size hip articulations may improve range of motion (ROM) and function compared to a 28–mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA) could impair rehabilitation. We investigated the effect of head size and surgical procedure on postoperative rehabilitation in a randomized clinical trial (RCT). Methods We followed randomized groups of RHAs, large–head THAs and standard THAs at 2 months, 6 months, 1 and 2 years postoperatively, recording clinical rehabilitation parameters. Results Large articulations increased the mean total range of motion by 13° during the first 6 postoperative months. The increase was not statistically significant and was transient. The 2–year total ROM (SD) for RHA, standard THA, and large–head THA was 221° (35), 232° (36), and 225° (30) respectively, but the differences were not statistically significant. The 3 groups were similar regarding Harris hip score, UCLA activity score, step rate, and sick leave. Interpretation Head size had no influence on range of motion. The lack of restriction allowed for large articulations did not improve the clinical and patient–perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762. PMID:23530872
Liu, Shen; Liu, Jun-jian; Li, Xu-jun; Ruan, Hong-jiang; Fan, Cun-yi
2013-02-01
Limited forearm rotation is a frequent combined disorder in elbow stiffness. If the radial head cannot be saved during open arthrolysis, prosthetic replacement might be considered because it enhances stability and allows early motion. In this study we retrospectively analyzed the outcome of 8 patients (7 men, 1 woman) who underwent open arthrolysis and simultaneous prosthetic replacement after resection of the radial head to restore elbow range of motion and forearm rotation. Patients were a mean age of 31.7 years (range, 22-40 years). Postoperatively, the mean (range) active range of motion improved from 29.4° (0°-70°) to 113.1° (80°-135°), mean (range) supination increased from 38.8° (0°-80°) to 77.5° (50°-90°), and mean (range) pronation improved from 18.8° (0°-80°) to 68.8° (50°-80°). The Mayo Elbow Performance Score improved from a mean (range) of 57.5 (50-70) to 92.5 (85-100) points. No elbow valgus instability was detected over a mean duration of 26 months of follow-up. The implant was considered stable in all patients. Open arthrolysis and prosthetic replacement of the radial head are effective in treating elbow stiffness with associated rotation limitation after resection of the radial head. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
He, Lu; Yan, Xiaohua; Li, Jinling; Guan, Buyun; Ma, Liying; Chen, Ying; Mai, Jianning; Xu, Kaishou
2017-05-01
To compare the short-term efficacy of 2 dosages of stretching treatment on the clinical outcomes in infants with congenital muscular torticollis. This was a prospective randomized controlled study. Fifty infants with congenital muscular torticollis who were randomly assigned to 100-times stretching group and 50-times stretching group received stretching treatment for the affected sternocleidomastoid muscle. The outcomes including the head tilt, the cervical passive range of motion, and the muscle function of cervical lateral flexors determined by the muscle function scale were assessed at baseline and at 4 and 8 weeks after treatment. The sternocleidomastoid muscle growth analyzed by the thickness ratio of sternocleidomastoid muscles was measured using ultrasonography at baseline and 8 weeks after treatment. Except the ratio of muscle function scale scores, the postintervention outcomes were all significantly improved in both groups compared with baseline (P < 0.05). The 100-times stretching group showed greater improvement compared with 50-times stretching group in head tilt and cervical passive range of motion at 4 and 8 weeks after treatment (P < 0.05). Stretching treatment of 2 dosages may effectively improve head tilt, cervical passive range of motion, and sternocleidomastoid muscle growth in infants with congenital muscular torticollis. The stretching treatment of 100 times per day is likely to associate with greater improvement in head tilt and cervical passive range of motion.
Vaina, Lucia M.; Buonanno, Ferdinando; Rushton, Simon K.
2014-01-01
Background All contemporary models of perception of locomotor heading from optic flow (the characteristic patterns of retinal motion that result from self-movement) begin with relative motion. Therefore it would be expected that an impairment on perception of relative motion should impact on the ability to judge heading and other 3D motion tasks. Material/Methods We report two patients with occipital lobe lesions whom we tested on a battery of motion tasks. Patients were impaired on all tests that involved relative motion in plane (motion discontinuity, form from differences in motion direction or speed). Despite this they retained the ability to judge their direction of heading relative to a target. A potential confound is that observers can derive information about heading from scale changes bypassing the need to use optic flow. Therefore we ran further experiments in which we isolated optic flow and scale change. Results Patients’ performance was in normal ranges on both tests. The finding that ability to perceive heading can be retained despite an impairment on ability to judge relative motion questions the assumption that heading perception proceeds from initial processing of relative motion. Furthermore, on a collision detection task, SS and SR’s performance was significantly better for simulated forward movement of the observer in the 3D scene, than for the static observer. This suggests that in spite of severe deficits on relative motion in the frontoparlel (xy) plane, information from self-motion helped identification objects moving along an intercept 3D relative motion trajectory. Conclusions This result suggests a potential use of a flow parsing strategy to detect in a 3D world the trajectory of moving objects when the observer is moving forward. These results have implications for developing rehabilitation strategies for deficits in visually guided navigation. PMID:25183375
Kim, Bo-Been; Lee, Ji-Hyun; Jeong, Hyo-Jung; Cynn, Heon-Seock
2016-10-01
Forward head posture is a head-on-trunk malalignment, which results in musculoskeletal dysfunction and neck pain. To improve forward head posture, both the craniocervical flexion exercise and the suboccipital release technique have been used. The purpose of this study was to compare the immediate effects of craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise on craniovertebral angle, cervical flexion and extension range of motion, and the muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis during craniocervical flexion exercise in subjects with forward head posture. In total, 19 subjects (7 males, 12 females) with forward head posture were recruited using G-power software. Each subject performed craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise in random order. After one intervention was performed, the subject took a 20min wash out period to minimize any carry-over effect between interventions. Craniovertebral angle, cervical flexion and extension range of motion, and the muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis were measured. A one-way, repeated-measures ANOVA was used to assess differences between the effects of the craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise interventions in the same group. Craniovertebral angle (p<0.05), cervical flexion range of motion (p<0.05), and cervical extension range of motion (p<0.001) were significantly greater after suboccipital release combined with craniocervical flexion exercise compared to craniocervical flexion exercise alone. The muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis were significantly lower during suboccipital release combined with craniocervical flexion exercise than during craniocervical flexion exercise alone across all craniocervical flexion exercise phases except the first (all p<0.05). The addition of suboccipital release to craniocervical flexion exercise provided superior benefits relative to craniocervical flexion exercise alone as an intervention for subjects with forward head posture. Copyright © 2016 Elsevier Ltd. All rights reserved.
Application of differential game theory to role-determination in aerial combat
NASA Technical Reports Server (NTRS)
Merz, A. W.
1975-01-01
The development of criteria which specify the roles of pursuer and evader as functions of the relative geometry and of the important parameters of the problem are discussed. A reduced-order model of the relative motion is derived and discussed. In this model, the two aircraft move in the same plane at unequal but constant speeds, and with different maximum turn rates. The equations of relative motion are of third order, the dependent variables being the relative range, bearing, and heading of the two aircraft. Termination of the pursuit-evasion game is defined by either the heading-limited or the range-limited end condition. These are geometric conditions for which the evading aircraft is in front of the other, with the relative heading and relative range satisfying certain inequalities. Retrograde solutions to the equations of relative motion were used with the derived optimal terminal maneuvers to find where an assumed set of end conditions could have begun.
Caballero, Carla; Mistry, Sejal; Vero, Joe; Torres, Elizabeth B
2018-01-01
The variability inherently present in biophysical data is partly contributed by disparate sampling resolutions across instrumentations. This poses a potential problem for statistical inference using pooled data in open access repositories. Such repositories combine data collected from multiple research sites using variable sampling resolutions. One example is the Autism Brain Imaging Data Exchange repository containing thousands of imaging and demographic records from participants in the spectrum of autism and age-matched neurotypical controls. Further, statistical analyses of groups from different diagnoses and demographics may be challenging, owing to the disparate number of participants across different clinical subgroups. In this paper, we examine the noise signatures of head motion data extracted from resting state fMRI data harnessed under different sampling resolutions. We characterize the quality of the noise in the variability of the raw linear and angular speeds for different clinical phenotypes in relation to age-matched controls. Further, we use bootstrapping methods to ensure compatible group sizes for statistical comparison and report the ranges of physical involuntary head excursions of these groups. We conclude that different sampling rates do affect the quality of noise in the variability of head motion data and, consequently, the type of random process appropriate to characterize the time series data. Further, given a qualitative range of noise, from pink to brown noise, it is possible to characterize different clinical subtypes and distinguish them in relation to ranges of neurotypical controls. These results may be of relevance to the pre-processing stages of the pipeline of analyses of resting state fMRI data, whereby head motion enters the criteria to clean imaging data from motion artifacts. PMID:29556179
NASA Astrophysics Data System (ADS)
White, Brian; Squires, Todd M.; Hain, Timothy C.; Stone, Howard A.
2003-11-01
Benign paroxysmal positional vertigo (BPPV) is a mechanical disorder of the vestibular system where micron-size crystals abnormally drift into the semicircular canals of the inner ear that sense angular motion of the head. Sedimentation of these crystals causes sensation of motion after true head motion has stopped: vertigo results. The usual clinical treatment is through a series of head maneuvers designed to move the particles into a less sensitive region of the canal system. We present a three-dimensional model to simulate treatment of BPPV by determining the complete hydrodynamic motion of the particles through the course of a therapeutic maneuver while using a realistic representation of the actual geometry. Analyses of clinical maneuvers show the parameter range for which they are effective, and indicate inefficiencies in current practice. In addition, an optimization process determines the most effective head maneuver, which significantly differs from those currently in practice.
Schoenecker, P L
1986-09-01
Legg-Calvé-Perthes disease, or osteochondrosis of the femoral head, occurs predominantly in boys 4 to 7 years of age. The disease progresses through synovitis, necrosis, fragmentation, and a residual stage. Outcome can be affected by age at disease onset, the extent of femoral head involvement as determined by x-ray, and the degree to which normal range of motion is maintained. The goal of treatment is to minimize residual deformity of the femoral head and acetabulum. This is accomplished by containing the femoral head well within the acetabulum and maintaining range of motion while the disease process runs its course. In extremely young patients, containment is often achieved during normal daily living activities. Containment treatment methods include abduction casting or orthosis; surgical containment can be accomplished by femoral or innominate osteotomy.
Development of a Mandibular Motion Simulator for Total Joint Replacement
Celebi, Nukhet; Rohner, E. Carlos; Gateno, Jaime; Noble, Philip C.; Ismaily, Sabir K.; Teichgraeber, John F.; Xia, James J.
2015-01-01
Purpose The purpose of this study was to develop a motion simulator capable of recreating and recording the full range of mandibular motions in a cadaveric preparation for an intact temporomandibular joint (TMJ) and after total joint replacement. Material and Methods A human cadaver head was used. Two sets of tracking balls were attached to the forehead and mandible, respectively. Computed tomographic (CT) scan was performed and 3-dimensional CT models of the skull were generated. The cadaver head was then dissected to attach the muscle activation cables and mounted onto the TMJ simulator. Realistic jaw motions were generated through the application of the following muscle forces: lateral pterygoid muscle, suprahyoid depressors (geniohyoid, mylohyoid, and digastric muscles), and elevator muscles. To simulate muscle contraction, cables were inserted into the mandible at the center area of each muscle's attachment. To provide a minimum mouth closing force at the initial position, the elevator muscles were combined at the anterior mandible. During mandibular movement, each motion was recorded using a high-resolution laser scanner. The right TMJ of the same head was reconstructed with a total TMJ prosthesis. The same forces were applied and the jaw motions were recorded again. CT scan was performed and 3-dimensional CT models of the skull with TMJ prosthesis were generated. Results Mandibular motions, before and after TMJ replacement, with and without lateral pterygoid muscle reattachment, were re-created in a cadaveric preparation. The laser-scanned data during the mandibular motion were used to drive 3-dimensional CT models. A movie for each mandibular motion was subsequently created for motion path analysis. Compared with mandibular motion before TMJ replacement, mandibular lateral and protrusive motions after TMJ replacement, with and without lateral pterygoid muscle reattachment, were greatly limited. The jaw motion recorded before total joint replacement was applied to the mandibular and prostheses models after total TMJ replacement. The condylar component was observed sinking into the fossa during jaw motion. Conclusion A motion simulator capable of re-creating and recording full range of mandibular motions in a cadaveric preparation has been developed. It can be used to simulate mandibular motions for the intact TMJ and total joint prosthesis, and to re-create and record their full range of mandibular motions. In addition, the full range of the recorded motion can be re-created as motion images in a computer. These images can be used for motion path analysis and to study the causation of limited range of motion after total joint replacement and strategies for improvement. PMID:21050636
Selection of head and whisker coordination strategies during goal-oriented active touch.
Schroeder, Joseph B; Ritt, Jason T
2016-04-01
In the rodent whisker system, a key model for neural processing and behavioral choices during active sensing, whisker motion is increasingly recognized as only part of a broader motor repertoire employed by rodents during active touch. In particular, recent studies suggest whisker and head motions are tightly coordinated. However, conditions governing the selection and temporal organization of such coordinated sensing strategies remain poorly understood. We videographically reconstructed head and whisker motions of freely moving mice searching for a randomly located rewarded aperture, focusing on trials in which animals appeared to rapidly "correct" their trajectory under tactile guidance. Mice orienting after unilateral contact repositioned their whiskers similarly to previously reported head-turning asymmetry. However, whisker repositioning preceded head turn onsets and was not bilaterally symmetric. Moreover, mice selectively employed a strategy we term contact maintenance, with whisking modulated to counteract head motion and facilitate repeated contacts on subsequent whisks. Significantly, contact maintenance was not observed following initial contact with an aperture boundary, when the mouse needed to make a large corrective head motion to the front of the aperture, but only following contact by the same whisker field with the opposite aperture boundary, when the mouse needed to precisely align its head with the reward spout. Together these results suggest that mice can select from a diverse range of sensing strategies incorporating both knowledge of the task and whisk-by-whisk sensory information and, moreover, suggest the existence of high level control (not solely reflexive) of sensing motions coordinated between multiple body parts. Copyright © 2016 the American Physiological Society.
Selection of head and whisker coordination strategies during goal-oriented active touch
2016-01-01
In the rodent whisker system, a key model for neural processing and behavioral choices during active sensing, whisker motion is increasingly recognized as only part of a broader motor repertoire employed by rodents during active touch. In particular, recent studies suggest whisker and head motions are tightly coordinated. However, conditions governing the selection and temporal organization of such coordinated sensing strategies remain poorly understood. We videographically reconstructed head and whisker motions of freely moving mice searching for a randomly located rewarded aperture, focusing on trials in which animals appeared to rapidly “correct” their trajectory under tactile guidance. Mice orienting after unilateral contact repositioned their whiskers similarly to previously reported head-turning asymmetry. However, whisker repositioning preceded head turn onsets and was not bilaterally symmetric. Moreover, mice selectively employed a strategy we term contact maintenance, with whisking modulated to counteract head motion and facilitate repeated contacts on subsequent whisks. Significantly, contact maintenance was not observed following initial contact with an aperture boundary, when the mouse needed to make a large corrective head motion to the front of the aperture, but only following contact by the same whisker field with the opposite aperture boundary, when the mouse needed to precisely align its head with the reward spout. Together these results suggest that mice can select from a diverse range of sensing strategies incorporating both knowledge of the task and whisk-by-whisk sensory information and, moreover, suggest the existence of high level control (not solely reflexive) of sensing motions coordinated between multiple body parts. PMID:26792880
Correction for human head motion in helical x-ray CT
NASA Astrophysics Data System (ADS)
Kim, J.-H.; Sun, T.; Alcheikh, A. R.; Kuncic, Z.; Nuyts, J.; Fulton, R.
2016-02-01
Correction for rigid object motion in helical CT can be achieved by reconstructing from a modified source-detector orbit, determined by the object motion during the scan. This ensures that all projections are consistent, but it does not guarantee that the projections are complete in the sense of being sufficient for exact reconstruction. We have previously shown with phantom measurements that motion-corrected helical CT scans can suffer from data-insufficiency, in particular for severe motions and at high pitch. To study whether such data-insufficiency artefacts could also affect the motion-corrected CT images of patients undergoing head CT scans, we used an optical motion tracking system to record the head movements of 10 healthy volunteers while they executed each of the 4 different types of motion (‘no’, slight, moderate and severe) for 60 s. From these data we simulated 354 motion-affected CT scans of a voxelized human head phantom and reconstructed them with and without motion correction. For each simulation, motion-corrected (MC) images were compared with the motion-free reference, by visual inspection and with quantitative similarity metrics. Motion correction improved similarity metrics in all simulations. Of the 270 simulations performed with moderate or less motion, only 2 resulted in visible residual artefacts in the MC images. The maximum range of motion in these simulations would encompass that encountered in the vast majority of clinical scans. With severe motion, residual artefacts were observed in about 60% of the simulations. We also evaluated a new method of mapping local data sufficiency based on the degree to which Tuy’s condition is locally satisfied, and observed that areas with high Tuy values corresponded to the locations of residual artefacts in the MC images. We conclude that our method can provide accurate and artefact-free MC images with most types of head motion likely to be encountered in CT imaging, provided that the motion can be accurately determined.
A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series.
Patel, Ameera X; Kundu, Prantik; Rubinov, Mikail; Jones, P Simon; Vértes, Petra E; Ersche, Karen D; Suckling, John; Bullmore, Edward T
2014-07-15
The impact of in-scanner head movement on functional magnetic resonance imaging (fMRI) signals has long been established as undesirable. These effects have been traditionally corrected by methods such as linear regression of head movement parameters. However, a number of recent independent studies have demonstrated that these techniques are insufficient to remove motion confounds, and that even small movements can spuriously bias estimates of functional connectivity. Here we propose a new data-driven, spatially-adaptive, wavelet-based method for identifying, modeling, and removing non-stationary events in fMRI time series, caused by head movement, without the need for data scrubbing. This method involves the addition of just one extra step, the Wavelet Despike, in standard pre-processing pipelines. With this method, we demonstrate robust removal of a range of different motion artifacts and motion-related biases including distance-dependent connectivity artifacts, at a group and single-subject level, using a range of previously published and new diagnostic measures. The Wavelet Despike is able to accommodate the substantial spatial and temporal heterogeneity of motion artifacts and can consequently remove a range of high and low frequency artifacts from fMRI time series, that may be linearly or non-linearly related to physical movements. Our methods are demonstrated by the analysis of three cohorts of resting-state fMRI data, including two high-motion datasets: a previously published dataset on children (N=22) and a new dataset on adults with stimulant drug dependence (N=40). We conclude that there is a real risk of motion-related bias in connectivity analysis of fMRI data, but that this risk is generally manageable, by effective time series denoising strategies designed to attenuate synchronized signal transients induced by abrupt head movements. The Wavelet Despiking software described in this article is freely available for download at www.brainwavelet.org. Copyright © 2014. Published by Elsevier Inc.
A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series
Patel, Ameera X.; Kundu, Prantik; Rubinov, Mikail; Jones, P. Simon; Vértes, Petra E.; Ersche, Karen D.; Suckling, John; Bullmore, Edward T.
2014-01-01
The impact of in-scanner head movement on functional magnetic resonance imaging (fMRI) signals has long been established as undesirable. These effects have been traditionally corrected by methods such as linear regression of head movement parameters. However, a number of recent independent studies have demonstrated that these techniques are insufficient to remove motion confounds, and that even small movements can spuriously bias estimates of functional connectivity. Here we propose a new data-driven, spatially-adaptive, wavelet-based method for identifying, modeling, and removing non-stationary events in fMRI time series, caused by head movement, without the need for data scrubbing. This method involves the addition of just one extra step, the Wavelet Despike, in standard pre-processing pipelines. With this method, we demonstrate robust removal of a range of different motion artifacts and motion-related biases including distance-dependent connectivity artifacts, at a group and single-subject level, using a range of previously published and new diagnostic measures. The Wavelet Despike is able to accommodate the substantial spatial and temporal heterogeneity of motion artifacts and can consequently remove a range of high and low frequency artifacts from fMRI time series, that may be linearly or non-linearly related to physical movements. Our methods are demonstrated by the analysis of three cohorts of resting-state fMRI data, including two high-motion datasets: a previously published dataset on children (N = 22) and a new dataset on adults with stimulant drug dependence (N = 40). We conclude that there is a real risk of motion-related bias in connectivity analysis of fMRI data, but that this risk is generally manageable, by effective time series denoising strategies designed to attenuate synchronized signal transients induced by abrupt head movements. The Wavelet Despiking software described in this article is freely available for download at www.brainwavelet.org. PMID:24657353
An operating principle of the turtle utricle to detect wide dynamic range.
Nam, Jong-Hoon
2018-03-01
The utricle encodes both static information such as head orientation, and dynamic information such as vibrations. It is not well understood how the utricle can encode both static and dynamic information for a wide dynamic range (from <0.05 to >2 times the gravitational acceleration; from DC to > 1000 Hz vibrations). Using computational models of the hair cells in the turtle utricle, this study presents an explanation on how the turtle utricle encodes stimulations over such a wide dynamic range. Two hair bundles were modeled using the finite element method-one representing the striolar hair cell (Cell S), and the other representing the medial extrastriolar hair cell (Cell E). A mechano-transduction (MET) channel model was incorporated to compute MET current (i MET ) due to hair bundle deflection. A macro-mechanical model of the utricle was used to compute otoconial motions from head accelerations (a Head ). According to known anatomical data, Cell E has a long kinocilium that is embedded into the stiff otoconial layer. Unlike Cell E, the hair bundle of Cell S falls short of the otoconial layer. Considering such difference in the mechanical connectivity between the hair cell bundle and the otoconial layer, three cases were simulated: Cell E displacement-clamped, Cell S viscously-coupled, and Cell S displacement-clamped. Head accelerations at different amplitude levels and different frequencies were simulated for the three cases. When a realistic head motion was simulated, Cell E was responsive to head orientation, while the viscously-coupled Cell S was responsive to fast head motion imitating the feeding strike of a turtle. Copyright © 2017 Elsevier B.V. All rights reserved.
Prospective motion correction using inductively coupled wireless RF coils.
Ooi, Melvyn B; Aksoy, Murat; Maclaren, Julian; Watkins, Ronald D; Bammer, Roland
2013-09-01
A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio-frequency coils, or "wireless markers," for position tracking. Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil. Real-time tracking of rigid head motion is performed using a pair of glasses integrated with three wireless markers. A tracking pulse-sequence, combined with knowledge of the markers' unique geometrical arrangement, is used to measure their positions. Tracking data from the glasses is then used to prospectively update the orientation and position of the image-volume so that it follows the motion of the head. Wireless-marker position measurements were comparable to measurements using traditional wired radio-frequency tracking coils, with the standard deviation of the difference < 0.01 mm over the range of positions measured inside the head coil. Wireless-marker safety was verified with B1 maps and temperature measurements. Prospective motion correction was demonstrated in a 2D spin-echo scan while the subject performed a series of deliberate head rotations. Prospective motion correction using wireless markers enables high quality images to be acquired even during bulk motions. Wireless markers are small, avoid radio-frequency safety risks from electrical cables, are not hampered by mechanical connections to the scanner, and require minimal setup times. These advantages may help to facilitate adoption in the clinic. Copyright © 2013 Wiley Periodicals, Inc.
Prospective Motion Correction using Inductively-Coupled Wireless RF Coils
Ooi, Melvyn B.; Aksoy, Murat; Maclaren, Julian; Watkins, Ronald D.; Bammer, Roland
2013-01-01
Purpose A novel prospective motion correction technique for brain MRI is presented that uses miniature wireless radio-frequency (RF) coils, or “wireless markers”, for position tracking. Methods Each marker is free of traditional cable connections to the scanner. Instead, its signal is wirelessly linked to the MR receiver via inductive coupling with the head coil. Real-time tracking of rigid head motion is performed using a pair of glasses integrated with three wireless markers. A tracking pulse-sequence, combined with knowledge of the markers’ unique geometrical arrangement, is used to measure their positions. Tracking data from the glasses is then used to prospectively update the orientation and position of the image-volume so that it follows the motion of the head. Results Wireless-marker position measurements were comparable to measurements using traditional wired RF tracking coils, with the standard deviation of the difference < 0.01 mm over the range of positions measured inside the head coil. RF safety was verified with B1 maps and temperature measurements. Prospective motion correction was demonstrated in a 2D spin-echo scan while the subject performed a series of deliberate head rotations. Conclusion Prospective motion correction using wireless markers enables high quality images to be acquired even during bulk motions. Wireless markers are small, avoid RF safety risks from electrical cables, are not hampered by mechanical connections to the scanner, and require minimal setup times. These advantages may help to facilitate adoption in the clinic. PMID:23813444
Turbulence Measurements from Compliant Moorings - Part I: Motion Characterization
Harding, Samuel; Kilcher, Levi; Thomson, Jim
2017-06-20
High-fidelity measurements of turbulence in the ocean have long been challenging to collect, in particular in the middle of the water column. In response, a measurement technique has been developed to deploy an Acoustic Doppler Velocimeter (ADV) to mid-water locations on a compliant mooring. A variety of instrumentation platforms have been deployed as part of this work with a range of dynamic motion characteristics. The platforms discussed herein include the streamlined StableMoor™ buoy (SMB), the Tidal Turbulence Mooring (TTM) system based on a conventional 0.9 m spherical buoy, and a 100 lb sounding weight suspended from the stern of amore » research vessel. The ADV head motion is computed from inertial motion sensors integrated into an ADV, and the spectra of these signals are investigated to quantify the motion of each platform. The SMB with a single ADV head mounted on the nose provided the most stable platform for the measurement of tidal turbulence in the inertial sub-range for flow speeds exceeding 1:0 ms -1. The modification of the SMB with a transverse wing configuration for multiple ADVs showed a similar frequency response to the nose configuration in the horizontal plane but with large contamination in the vertical direction as a result of platform roll. While the ADV motion on the TTM was significant in the horizontal directions, the vertical motion of this configuration was the most stable of all configurations tested. The sounding weight measurements showed the greatest motion at the ADV head but are likely to be influenced by both prop-wash and vessel motion.« less
Auditory compensation for head rotation is incomplete.
Freeman, Tom C A; Culling, John F; Akeroyd, Michael A; Brimijoin, W Owen
2017-02-01
Hearing is confronted by a similar problem to vision when the observer moves. The image motion that is created remains ambiguous until the observer knows the velocity of eye and/or head. One way the visual system solves this problem is to use motor commands, proprioception, and vestibular information. These "extraretinal signals" compensate for self-movement, converting image motion into head-centered coordinates, although not always perfectly. We investigated whether the auditory system also transforms coordinates by examining the degree of compensation for head rotation when judging a moving sound. Real-time recordings of head motion were used to change the "movement gain" relating head movement to source movement across a loudspeaker array. We then determined psychophysically the gain that corresponded to a perceptually stationary source. Experiment 1 showed that the gain was small and positive for a wide range of trained head speeds. Hence, listeners perceived a stationary source as moving slightly opposite to the head rotation, in much the same way that observers see stationary visual objects move against a smooth pursuit eye movement. Experiment 2 showed the degree of compensation remained the same for sounds presented at different azimuths, although the precision of performance declined when the sound was eccentric. We discuss two possible explanations for incomplete compensation, one based on differences in the accuracy of signals encoding image motion and self-movement and one concerning statistical optimization that sacrifices accuracy for precision. We then consider the degree to which such explanations can be applied to auditory motion perception in moving listeners. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Head eye co-ordination and gaze stability in subjects with persistent whiplash associated disorders.
Treleaven, Julia; Jull, Gwendolen; Grip, Helena
2011-06-01
Symptoms of dizziness, unsteadiness and visual disturbances are frequent complaints in persons with persistent whiplash associated disorders. This study investigated eye, head co-ordination and gaze stability in subjects with persistent whiplash (n = 20) and asymptomatic controls (n = 20). Wireless motion sensors and electro-oculography were used to measure: head rotation during unconstrained head movement, head rotation during gaze stability and sequential head and eye movements. Ten control subjects participated in a repeatability study (two occasions one week apart). Between-day repeatability was acceptable (ICC > 0.6) for most measures. The whiplash group had significantly less maximal eye angle to the left, range of head movement during the gaze stability task and decreased velocity of head movement in head eye co-ordination and gaze stability tasks compared to the control group (p < 0.01). There were significant correlations (r > 0.55) between both unrestrained neck movement and neck pain and head movement and velocity in the whiplash group. Deficits in gaze stability and head eye co-ordination may be related to disturbed reflex activity associated with decreased head range of motion and/or neck pain. Further research is required to explore the mechanisms behind these deficits, the nature of changes over time and the tests' ability to measure change in response to rehabilitation. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Translation and Rotation Trade Off in Human Visual Heading Estimation
NASA Technical Reports Server (NTRS)
Stone, Leland S.; Perrone, John A.; Null, Cynthia H. (Technical Monitor)
1996-01-01
We have previously shown that, during simulated curvilinear motion, humans can make reasonably accurate and precise heading judgments from optic flow without either oculomotor or static-depth cues about rotation. We now systematically investigate the effect of varying the parameters of self-motion. We visually simulated 400 ms of self-motion along curved paths (constant rotation and translation rates, fixed retinocentric heading) towards two planes of random dots at 10.3 m and 22.3 m at mid-trial. Retinocentric heading judgments of 4 observers (2 naive) were measured for 12 different combinations of translation (T between 4 and 16 m/s) and rotation (R either 8 or 16 deg/s). In the range tested, heading bias and uncertainty decrease quasilinearly with T/R, but the bias also appears to depend on R. If depth is held constant, the ratio T/R can account for much of the variation in the accuracy and precision of human visual heading estimation, although further experiments are needed to resolve whether absolute rotation rate, total flow rate, or some other factor can account for the observed -2 deg shift between the bias curves.
WHIPS seat and occupant motions during simulated rear crashes.
Xiao, Ming; Ivancic, Paul C
2010-10-01
Objectives of this study were to investigate the motions of Volvo's Whiplash Protection System (WHIPS) seat and occupant during simulated rear crashes of a human model of the neck (HUMON). HUMON consisted of a human neck specimen (n = 6) mounted to the torso of BioRID II and carrying an anthropometric head stabilized with muscle force replication. HUMON was seated and secured in a 2005 Volvo XC90 minivan seat that included WHIPS and a fixed head restraint. Rear crashes of 9.9 g (ΔV 9.2 kph), 12.0 g (ΔV 11.4 kph), and 13.3 g (ΔV 13.4 kph) were simulated and WHIPS and occupant motions were monitored. Linear regression analyses (P < .05) were used to determine relationships between WHIPS and occupant motion peaks using data from all crashes combined. WHIPS motions consisted of simultaneous rearward and downward translations and extension of the seatback and plastic deformation of the bilateral WHIPS energy-absorbing components. Peak WHIPS motions were linearly correlated only with peak rearward occupant translations. Less rearward pelvis translation was required to cause WHIPS activation as compared to T1 translation. WHIPS reduced peak T1 horizontal acceleration by 39 percent compared to sled acceleration. This was within the range previously reported for WHIPS, between 30 and 60 percent, but higher than the 16 percent reduction previously reported due to active head restraint. Absorption of crash energy occurred during the initial 75 ms and the onset of head support occurred at 114 ms. Differential head-torso motions occurred prior to and during head support, indicating the potential for neck injury even with WHIPS.
PROMO – Real-time Prospective Motion Correction in MRI using Image-based Tracking
White, Nathan; Roddey, Cooper; Shankaranarayanan, Ajit; Han, Eric; Rettmann, Dan; Santos, Juan; Kuperman, Josh; Dale, Anders
2010-01-01
Artifacts caused by patient motion during scanning remain a serious problem in most MRI applications. The prospective motion correction technique attempts to address this problem at its source by keeping the measurement coordinate system fixed with respect to the patient throughout the entire scan process. In this study, a new image-based approach for prospective motion correction is described, which utilizes three orthogonal 2D spiral navigator acquisitions (SP-Navs) along with a flexible image-based tracking method based on the Extended Kalman Filter (EKF) algorithm for online motion measurement. The SP-Nav/EKF framework offers the advantages of image-domain tracking within patient-specific regions-of-interest and reduced sensitivity to off-resonance-induced corruption of rigid-body motion estimates. The performance of the method was tested using offline computer simulations and online in vivo head motion experiments. In vivo validation results covering a broad range of staged head motions indicate a steady-state error of the SP-Nav/EKF motion estimates of less than 10 % of the motion magnitude, even for large compound motions that included rotations over 15 degrees. A preliminary in vivo application in 3D inversion recovery spoiled gradient echo (IR-SPGR) and 3D fast spin echo (FSE) sequences demonstrates the effectiveness of the SP-Nav/EKF framework for correcting 3D rigid-body head motion artifacts prospectively in high-resolution 3D MRI scans. PMID:20027635
Markerless motion estimation for motion-compensated clinical brain imaging
NASA Astrophysics Data System (ADS)
Kyme, Andre Z.; Se, Stephen; Meikle, Steven R.; Fulton, Roger R.
2018-05-01
Motion-compensated brain imaging can dramatically reduce the artifacts and quantitative degradation associated with voluntary and involuntary subject head motion during positron emission tomography (PET), single photon emission computed tomography (SPECT) and computed tomography (CT). However, motion-compensated imaging protocols are not in widespread clinical use for these modalities. A key reason for this seems to be the lack of a practical motion tracking technology that allows for smooth and reliable integration of motion-compensated imaging protocols in the clinical setting. We seek to address this problem by investigating the feasibility of a highly versatile optical motion tracking method for PET, SPECT and CT geometries. The method requires no attached markers, relying exclusively on the detection and matching of distinctive facial features. We studied the accuracy of this method in 16 volunteers in a mock imaging scenario by comparing the estimated motion with an accurate marker-based method used in applications such as image guided surgery. A range of techniques to optimize performance of the method were also studied. Our results show that the markerless motion tracking method is highly accurate (<2 mm discrepancy against a benchmarking system) on an ethnically diverse range of subjects and, moreover, exhibits lower jitter and estimation of motion over a greater range than some marker-based methods. Our optimization tests indicate that the basic pose estimation algorithm is very robust but generally benefits from rudimentary background masking. Further marginal gains in accuracy can be achieved by accounting for non-rigid motion of features. Efficiency gains can be achieved by capping the number of features used for pose estimation provided that these features adequately sample the range of head motion encountered in the study. These proof-of-principle data suggest that markerless motion tracking is amenable to motion-compensated brain imaging and holds good promise for a practical implementation in clinical PET, SPECT and CT systems.
Song, Young Seop; Yang, Kyung Yong; Youn, Kibum; Yoon, Chiyul; Yeom, Jiwoon; Hwang, Hyeoncheol; Lee, Jehee; Kim, Keewon
2016-08-01
To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland-Altman plot with 95% limits of agreement (LoA). MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in -40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in -40° to 40° range were fair for all motions. Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.
Model of head-neck joint fast movements in the frontal plane.
Pedrocchi, A; Ferrigno, G
2004-06-01
The objective of this work is to develop a model representing the physiological systems driving fast head movements in frontal plane. All the contributions occurring mechanically in the head movement are considered: damping, stiffness, physiological limit of range of motion, gravitational field, and muscular torques due to voluntary activation as well as to stretch reflex depending on fusal afferences. Model parameters are partly derived from the literature, when possible, whereas undetermined block parameters are determined by optimising the model output, fitting to real kinematics data acquired by a motion capture system in specific experimental set-ups. The optimisation for parameter identification is performed by genetic algorithms. Results show that the model represents very well fast head movements in the whole range of inclination in the frontal plane. Such a model could be proposed as a tool for transforming kinematics data on head movements in 'neural equivalent data', especially for assessing head control disease and properly planning the rehabilitation process. In addition, the use of genetic algorithms seems to fit well the problem of parameter identification, allowing for the use of a very simple experimental set-up and granting model robustness.
Unconstrained tripolar hip implants: effect on hip stability.
Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan
2007-02-01
Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.
The Perception of Auditory Motion
Leung, Johahn
2016-01-01
The growing availability of efficient and relatively inexpensive virtual auditory display technology has provided new research platforms to explore the perception of auditory motion. At the same time, deployment of these technologies in command and control as well as in entertainment roles is generating an increasing need to better understand the complex processes underlying auditory motion perception. This is a particularly challenging processing feat because it involves the rapid deconvolution of the relative change in the locations of sound sources produced by rotational and translations of the head in space (self-motion) to enable the perception of actual source motion. The fact that we perceive our auditory world to be stable despite almost continual movement of the head demonstrates the efficiency and effectiveness of this process. This review examines the acoustical basis of auditory motion perception and a wide range of psychophysical, electrophysiological, and cortical imaging studies that have probed the limits and possible mechanisms underlying this perception. PMID:27094029
Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults
Dudani, Baldev; Shyam, Ashok K; Arora, Pankush; Veigus, Arjun
2015-01-01
Background: Bipolar hip arthroplasty (BHA) is one of the options for treatment of avascular necrosis (AVN) of the femoral head. Acetabular erosion and groin pain are the most allowing for gross motion between the common complications. We propose that these complications are secondary to improper acetabular preparation allowing for motion between the BHA head and the acetabulum. Materials and Methods: The current study retrospectively evaluated patients’records from case files and also called them for clinical and radiological followup. 96 hips with AVN of the femoral head treated with BHA were included in the study. All patients were males with a mean age of 42 years (range 30-59 years). In all cases, the acetabulum was gently reamed till it became uniformly concentric to achieve tight fitting trial cup. Clinical followup using Harris hip score (HHS) and radiological study for cup migration were done at followup. Results: The mean followup was 7.52 years (range 4-16 years). The HHS significantly improved from a preoperative value of 39.3 (range, 54-30) to a postoperative value of 89.12 (range 74-96). According to HHS grades, the final outcome was excellent in 52 hips, good in 28 and fair in 16 hips. Hip and groin pain was reported in four hips (5%), but did not limit activity. Subsidence (less than 5 mm) of the femoral component was seen in 8 cases. Subgroup analysis showed patients with Ficat Stage 3 having better range of motion, but similar HHS as compared to Ficat Stage 4 patients. Conclusion: Bipolar hip arthroplasty (BHA) using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage. PMID:26015634
Radial Head Prosthesis Removal: a Retrospective Case Series of 14 Patients
Neuhaus, Valentin; Christoforou, Dimitrios C.; Kachooei, Amir Reza; Jupiter, Jesse B.; Ring, David C.; Mudgal, Chaitanya S.
2015-01-01
Background: The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis. Methods: This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 months (range from 2 weeks to 12 years, median 12 months). Results: The leading reported complaints before removal were restricted mobility of the elbow (active range of motion of less than 100 degrees) in 6, pain in 3, and pain together with restricted mobility in 4 patients. The objective findings before removal were restricted mobility of the elbow in 10 (71%), capitellar cartilage wear, loose implants, and heterotopic ossification each in 8 (57%), subluxation of the radio-capitellar joint or malpositioning of the stem in 5 (36%), and chronic infection in 2 (14%) patients. All patients with pain had wear of the capitellar cartilage on radiographs. The ulnar nerve was decompressed in four patients at the time of removal. Four patients underwent a subsequent operation for postoperative ulnar nerve symptoms 5 to 21 months after removal. Four patients were still complaining about persistent pain at the last follow-up visit. Except two patients, the total range of motion improved with a mean of 34 degrees (range 5 to 70) after a mean follow-up of 11 months. Conclusions: Removal of radial head prosthesis improved function and lessened pain in our case series. The reoperation rate was yet nearly 30% due to ulnar neuritis. Selective ulnar nerve decompression at the time of removal must be evaluated, especially in patients with expected large gain in range of motion after removal. PMID:26110173
Live Speech Driven Head-and-Eye Motion Generators.
Le, Binh H; Ma, Xiaohan; Deng, Zhigang
2012-11-01
This paper describes a fully automated framework to generate realistic head motion, eye gaze, and eyelid motion simultaneously based on live (or recorded) speech input. Its central idea is to learn separate yet interrelated statistical models for each component (head motion, gaze, or eyelid motion) from a prerecorded facial motion data set: 1) Gaussian Mixture Models and gradient descent optimization algorithm are employed to generate head motion from speech features; 2) Nonlinear Dynamic Canonical Correlation Analysis model is used to synthesize eye gaze from head motion and speech features, and 3) nonnegative linear regression is used to model voluntary eye lid motion and log-normal distribution is used to describe involuntary eye blinks. Several user studies are conducted to evaluate the effectiveness of the proposed speech-driven head and eye motion generator using the well-established paired comparison methodology. Our evaluation results clearly show that this approach can significantly outperform the state-of-the-art head and eye motion generation algorithms. In addition, a novel mocap+video hybrid data acquisition technique is introduced to record high-fidelity head movement, eye gaze, and eyelid motion simultaneously.
Evidence for a general stiffening motor control pattern in neck pain: a cross sectional study.
Meisingset, Ingebrigt; Woodhouse, Astrid; Stensdotter, Ann-Katrin; Stavdahl, Øyvind; Lorås, Håvard; Gismervik, Sigmund; Andresen, Hege; Austreim, Kristian; Vasseljen, Ottar
2015-03-17
Neck pain is associated with several alterations in neck motion and motor control. Previous studies have investigated single constructs of neck motor control, while few have applied a comprehensive set of tests to investigate cervical motor control. This comparative cross- sectional study aimed to investigate different motor control constructs in neck pain patients and healthy controls. A total of 166 subjects participated in the study, 91 healthy controls (HC) and 75 neck pain patients (NP) with long-lasting moderate to severe neck pain. Neck flexibility, proprioception, head steadiness, trajectory movement control, and postural sway were assessed using a 3D motion tracking system (Liberty). The different constructs of neck motion and motor control were based on tests used in previous studies. Neck flexibility was lower in NP compared to HC, indicated by reduced cervical ROM and conjunct motion. Movement velocity was slower in NP compared to HC. Tests of head steadiness showed a stiffer movement pattern in NP compared to HC, indicated by lower head angular velocity. NP patients departed less from a predictable trajectory movement pattern (figure of eight) compared to healthy controls, but there was no difference for unpredictable movement patterns (the Fly test). No differences were found for postural sway in standing with eyes open and eyes closed. However, NP patients had significantly larger postural sway when standing on a balance pad. Proprioception did not differ between the groups. Largest effect sizes (ES) were found for neck flexibility (ES range: 0.2-0.8) and head steadiness (ES range: 1.3-2.0). Neck flexibility was the only construct that showed a significant association with current neck pain, while peak velocity was the only variable that showed a significant association with kinesiophobia. NP patients showed an overall stiffer and more rigid neck motor control pattern compared to HC, indicated by lower neck flexibility, slower movement velocity, increased head steadiness and more rigid trajectory head motion patterns. Only neck flexibility showed a significant association with clinical features in NP patients.
Heikkilä, H V; Wenngren, B I
1998-09-01
To investigate cervicocephalic kinesthetic sensibility, active range of cervical motion, and oculomotor function in patients with whiplash injury. A 2-year review of consecutive patients admitted to the emergency unit after whiplash injury. An otorhinolaryngology department. Twenty-seven consecutive patients with diagnosed whiplash injury (14 men and 13 women, mean age, 33.8yrs [range, 18 to 66yrs]). The controls were healthy subjects without a history of whiplash injury. Oculomotor function was tested at 2 months and at 2 years after whiplash injury. The ability to appreciate both movement and head position was studied. Active range of cervical motion was measured. Subjective intensity of neck pain and major medical symptoms were recorded. Active head repositioning was significantly less precise in the whiplash subjects than in the control group. Failures in oculomotor functions were observed in 62% of subjects. Significant correlations occurred between smooth pursuit tests and active cervical range of motion. Correlations also were established between the oculomotor test and the kinesthetic sensibility test. The results suggest that restricted cervical movements and changes in the quality of proprioceptive information from the cervical spine region affect voluntary eye movements. A flexion/extension injury to the neck may result in dysfunction of the proprioceptive system. Oculomotor dysfunction after neck trauma might be related to cervical afferent input disturbances.
Assessment of musculoskeletal impairment in head and neck cancer patients.
Ghiam, Michael K; Mannion, Kyle; Dietrich, Mary S; Stevens, Kristen L; Gilbert, Jill; Murphy, Barbara A
2017-07-01
This study aims to describe the types of musculoskeletal impairment in head and neck cancer survivors and to evaluate objective and subjective measures of musculoskeletal impairment and identify areas of need in future studies. This is a cross-sectional pilot study of 29 head and neck cancer patients who were treated with resection and reconstruction. Subjective measures of musculoskeletal impairment (Neck Disability Index, Shoulder Pain and Disability Index, Vanderbilt Head and Neck Symptom Survey, General Symptom Survey) were collected and compared to objective measures (Cervical Range of Motion Device, Inter-incisal Distance). Digital photography was used to assess the severity of postural abnormalities. Findings were summarized using descriptive statistical and graphical methods. The majority of patients in this cohort suffered from neck disability (69%). Thirty-five percent of patients had shoulder pain and disability. Cervical range of motion deficits were observed in all directions. Inter-incisal distance averaged 33.4 mm and inversely correlated with self-reported jaw and trismus symptoms. Digital photography identified shoulder misalignment in 93% of subjects, head tilt in 89% of subjects, and postural deviation in 68% of subjects. Musculoskeletal impairment is a significant side effect in head and neck cancer survivors that results in chronic neck pain, shoulder disability, trismus, and postural deficits. Tools to describe postural deficits are needed.
Wada, Takahiro; Yoshida, Keigo
2016-08-01
This study examined the effect of passengers' active head-tilt and eyes-open/eyes-closed conditions on the severity of motion sickness in the lateral acceleration environment of cars. In the centrifugal head-tilt condition, participants intentionally tilted their heads towards the centrifugal force, whereas in the centripetal head-tilt condition, the participants tilted their heads against the centrifugal acceleration. The eyes-open and eyes-closed cases were investigated for each head-tilt condition. In the experimental runs, the sickness rating in the centripetal head-tilt condition was significantly lower than that in the centrifugal head-tilt condition. Moreover, the sickness rating in the eyes-open condition was significantly lower than that in the eyes-closed condition. The results suggest that an active head-tilt motion against the centrifugal acceleration reduces the severity of motion sickness both in the eyes-open and eyes-closed conditions. They also demonstrate that the eyes-open condition significantly reduces the motion sickness even when the head-tilt strategy is used. Practitioner Summary: Little is known about the effect of head-tilt strategies on motion sickness. This study investigated the effects of head-tilt direction and eyes-open/eyes-closed conditions on motion sickness during slalom automobile driving. Passengers' active head tilt towards the centripetal direction and the eyes-open condition greatly reduce the severity of motion sickness.
Sensory convergence in the parieto-insular vestibular cortex
Shinder, Michael E.
2014-01-01
Vestibular signals are pervasive throughout the central nervous system, including the cortex, where they likely play different roles than they do in the better studied brainstem. Little is known about the parieto-insular vestibular cortex (PIVC), an area of the cortex with prominent vestibular inputs. Neural activity was recorded in the PIVC of rhesus macaques during combinations of head, body, and visual target rotations. Activity of many PIVC neurons was correlated with the motion of the head in space (vestibular), the twist of the neck (proprioceptive), and the motion of a visual target, but was not associated with eye movement. PIVC neurons responded most commonly to more than one stimulus, and responses to combined movements could often be approximated by a combination of the individual sensitivities to head, neck, and target motion. The pattern of visual, vestibular, and somatic sensitivities on PIVC neurons displayed a continuous range, with some cells strongly responding to one or two of the stimulus modalities while other cells responded to any type of motion equivalently. The PIVC contains multisensory convergence of self-motion cues with external visual object motion information, such that neurons do not represent a specific transformation of any one sensory input. Instead, the PIVC neuron population may define the movement of head, body, and external visual objects in space and relative to one another. This comparison of self and external movement is consistent with insular cortex functions related to monitoring and explains many disparate findings of previous studies. PMID:24671533
Probabilistic description of infant head kinematics in abusive head trauma.
Lintern, T O; Nash, M P; Kelly, P; Bloomfield, F H; Taberner, A J; Nielsen, P M F
2017-12-01
Abusive head trauma (AHT) is a potentially fatal result of child abuse, but the mechanisms by which injury occur are often unclear. To investigate the contention that shaking alone can elicit the injuries observed, effective computational models are necessary. The aim of this study was to develop a probabilistic model describing infant head kinematics in AHT. A deterministic model incorporating an infant's mechanical properties, subjected to different shaking motions, was developed in OpenSim. A Monte Carlo analysis was used to simulate the range of infant kinematics produced as a result of varying both the mechanical properties and the type of shaking motions. By excluding physically unrealistic shaking motions, worst-case shaking scenarios were simulated and compared to existing injury criteria for a newborn, a 4.5 month-old, and a 12 month-old infant. In none of the three cases were head kinematics observed to exceed previously-estimated subdural haemorrhage injury thresholds. The results of this study provide no biomechanical evidence to demonstrate how shaking by a human alone can cause the injuries observed in AHT, suggesting either that additional factors, such as impact, are required, or that the current estimates of injury thresholds are incorrect.
The Influence of Head Motion on Intrinsic Functional Connectivity MRI
Van Dijk, Koene R.A.; Sabuncu, Mert R.; Buckner, Randy L.
2011-01-01
Functional connectivity MRI (fcMRI) has been widely applied to explore group and individual differences. A confounding factor is head motion. Children move more than adults, older adults more than younger adults, and patients more than controls. Head motion varies considerably among individuals within the same population. Here we explored the influence of head motion on fcMRI estimates. Mean head displacement, maximum head displacement, the number of micro movements (> 0.1 mm), and head rotation were estimated in 1000 healthy, young adult subjects each scanned for two resting-state runs on matched 3T scanners. The majority of fcMRI variation across subjects was not linked to estimated head motion. However, head motion had significant, systematic effects on fcMRI network measures. Head motion was associated with decreased functional coupling in the default and frontoparietal control networks – two networks characterized by coupling among distributed regions of association cortex. Other network measures increased with motion including estimates of local functional coupling and coupling between left and right motor regions – a region pair sometimes used as a control in studies to establish specificity. Comparisons between groups of individuals with subtly different levels of head motion yielded difference maps that could be mistaken for neuronal effects in other contexts. These effects are important to consider when interpreting variation between groups and across individuals. PMID:21810475
Keshner, E A; Dhaher, Y
2008-07-01
Multiplanar environmental motion could generate head instability, particularly if the visual surround moves in planes orthogonal to a physical disturbance. We combined sagittal plane surface translations with visual field disturbances in 12 healthy (29-31 years) and 3 visually sensitive (27-57 years) adults. Center of pressure (COP), peak head angles, and RMS values of head motion were calculated and a three-dimensional model of joint motion was developed to examine gross head motion in three planes. We found that subjects standing quietly in front of a visual scene translating in the sagittal plane produced significantly greater (p<0.003) head motion in yaw than when on a translating platform. However, when the platform was translated in the dark or with a visual scene rotating in roll, head motion orthogonal to the plane of platform motion significantly increased (p<0.02). Visually sensitive subjects having no history of vestibular disorder produced large, delayed compensatory head motion. Orthogonal head motions were significantly greater in visually sensitive than in healthy subjects in the dark (p<0.05) and with a stationary scene (p<0.01). We concluded that motion of the visual field could modify compensatory response kinematics of a freely moving head in planes orthogonal to the direction of a physical perturbation. These results suggest that the mechanisms controlling head orientation in space are distinct from those that control trunk orientation in space. These behaviors would have been missed if only COP data were considered. Data suggest that rehabilitation training can be enhanced by combining visual and mechanical perturbation paradigms.
Influence of visual path information on human heading perception during rotation.
Li, Li; Chen, Jing; Peng, Xiaozhe
2009-03-31
How does visual path information influence people's perception of their instantaneous direction of self-motion (heading)? We have previously shown that humans can perceive heading without direct access to visual path information. Here we vary two key parameters for estimating heading from optic flow, the field of view (FOV) and the depth range of environmental points, to investigate the conditions under which visual path information influences human heading perception. The display simulated an observer traveling on a circular path. Observers used a joystick to rotate their line of sight until deemed aligned with true heading. Four FOV sizes (110 x 94 degrees, 48 x 41 degrees, 16 x 14 degrees, 8 x 7 degrees) and depth ranges (6-50 m, 6-25 m, 6-12.5 m, 6-9 m) were tested. Consistent with our computational modeling results, heading bias increased with the reduction of FOV or depth range when the display provided a sequence of velocity fields but no direct path information. When the display provided path information, heading bias was not influenced as much by the reduction of FOV or depth range. We conclude that human heading and path perception involve separate visual processes. Path helps heading perception when the display does not contain enough optic-flow information for heading estimation during rotation.
Motion versus position in the perception of head-centred movement.
Freeman, Tom C A; Sumnall, Jane H
2002-01-01
Abstract. Observers can recover motion with respect to the head during an eye movement by comparing signals encoding retinal motion and the velocity of pursuit. Evidently there is a mismatch between these signals because perceived head-centred motion is not always veridical. One example is the Filehne illusion, in which a stationary object appears to move in the opposite direction to pursuit. Like the motion aftereffect, the phenomenal experience of the Filehne illusion is one in which the stimulus moves but does not seem to go anywhere. This raises problems when measuring the illusion by motion nulling because the more traditional technique confounds perceived motion with changes in perceived position. We devised a new nulling technique using global-motion stimuli that degraded familiar position cues but preserved cues to motion. Stimuli consisted of random-dot patterns comprising signal and noise dots that moved at the same retinal 'base' speed. Noise moved in random directions. In an eye-stationary speed-matching experiment we found noise slowed perceived retinal speed as 'coherence strength' (ie percentage of signal) was reduced. The effect occurred over the two-octave range of base speeds studied and well above direction threshold. When the same stimuli were combined with pursuit, observers were able to null the Filehne illusion by adjusting coherence. A power law relating coherence to retinal base speed fit the data well with a negative exponent. Eye-movement recordings showed that pursuit was quite accurate. We then tested the hypothesis that the stimuli found at the null-points appeared to move at the same retinal speed. Two observers supported the hypothesis, a third partially, and a fourth showed a small linear trend. In addition, the retinal speed found by the traditional Filehne technique was similar to the matches obtained with the global-motion stimuli. The results provide support for the idea that speed is the critical cue in head-centred motion perception.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Chuan; Brady, Thomas J.; El Fakhri, Georges
2014-04-15
Purpose: Artifacts caused by head motion present a major challenge in brain positron emission tomography (PET) imaging. The authors investigated the feasibility of using wired active MR microcoils to track head motion and incorporate the measured rigid motion fields into iterative PET reconstruction. Methods: Several wired active MR microcoils and a dedicated MR coil-tracking sequence were developed. The microcoils were attached to the outer surface of an anthropomorphic{sup 18}F-filled Hoffman phantom to mimic a brain PET scan. Complex rotation/translation motion of the phantom was induced by a balloon, which was connected to a ventilator. PET list-mode and MR tracking datamore » were acquired simultaneously on a PET-MR scanner. The acquired dynamic PET data were reconstructed iteratively with and without motion correction. Additionally, static phantom data were acquired and used as the gold standard. Results: Motion artifacts in PET images were effectively removed by wired active MR microcoil based motion correction. Motion correction yielded an activity concentration bias ranging from −0.6% to 3.4% as compared to a bias ranging from −25.0% to 16.6% if no motion correction was applied. The contrast recovery values were improved by 37%–156% with motion correction as compared to no motion correction. The image correlation (mean ± standard deviation) between the motion corrected (uncorrected) images of 20 independent noise realizations and static reference was R{sup 2} = 0.978 ± 0.007 (0.588 ± 0.010, respectively). Conclusions: Wired active MR microcoil based motion correction significantly improves brain PET quantitative accuracy and image contrast.« less
Huang, Chuan; Ackerman, Jerome L.; Petibon, Yoann; Brady, Thomas J.; El Fakhri, Georges; Ouyang, Jinsong
2014-01-01
Purpose: Artifacts caused by head motion present a major challenge in brain positron emission tomography (PET) imaging. The authors investigated the feasibility of using wired active MR microcoils to track head motion and incorporate the measured rigid motion fields into iterative PET reconstruction. Methods: Several wired active MR microcoils and a dedicated MR coil-tracking sequence were developed. The microcoils were attached to the outer surface of an anthropomorphic 18F-filled Hoffman phantom to mimic a brain PET scan. Complex rotation/translation motion of the phantom was induced by a balloon, which was connected to a ventilator. PET list-mode and MR tracking data were acquired simultaneously on a PET-MR scanner. The acquired dynamic PET data were reconstructed iteratively with and without motion correction. Additionally, static phantom data were acquired and used as the gold standard. Results: Motion artifacts in PET images were effectively removed by wired active MR microcoil based motion correction. Motion correction yielded an activity concentration bias ranging from −0.6% to 3.4% as compared to a bias ranging from −25.0% to 16.6% if no motion correction was applied. The contrast recovery values were improved by 37%–156% with motion correction as compared to no motion correction. The image correlation (mean ± standard deviation) between the motion corrected (uncorrected) images of 20 independent noise realizations and static reference was R2 = 0.978 ± 0.007 (0.588 ± 0.010, respectively). Conclusions: Wired active MR microcoil based motion correction significantly improves brain PET quantitative accuracy and image contrast. PMID:24694141
Visual Acuity Using Head-fixed Displays During Passive Self and Surround Motion
NASA Technical Reports Server (NTRS)
Wood, Scott J.; Black, F. Owen; Stallings, Valerie; Peters, Brian
2007-01-01
The ability to read head-fixed displays on various motion platforms requires the suppression of vestibulo-ocular reflexes. This study examined dynamic visual acuity while viewing a head-fixed display during different self and surround rotation conditions. Twelve healthy subjects were asked to report the orientation of Landolt C optotypes presented on a micro-display fixed to a rotating chair at 50 cm distance. Acuity thresholds were determined by the lowest size at which the subjects correctly identified 3 of 5 optotype orientations at peak velocity. Visual acuity was compared across four different conditions, each tested at 0.05 and 0.4 Hz (peak amplitude of 57 deg/s). The four conditions included: subject rotated in semi-darkness (i.e., limited to background illumination of the display), subject stationary while visual scene rotated, subject rotated around a stationary visual background, and both subject and visual scene rotated together. Visual acuity performance was greatest when the subject rotated around a stationary visual background; i.e., when both vestibular and visual inputs provided concordant information about the motion. Visual acuity performance was most reduced when the subject and visual scene rotated together; i.e., when the visual scene provided discordant information about the motion. Ranges of 4-5 logMAR step sizes across the conditions indicated the acuity task was sufficient to discriminate visual performance levels. The background visual scene can influence the ability to read head-fixed displays during passive motion disturbances. Dynamic visual acuity using head-fixed displays can provide an operationally relevant screening tool for visual performance during exposure to novel acceleration environments.
Keshner, E.A.; Dhaher, Y.
2008-01-01
Multiplanar environmental motion could generate head instability, particularly if the visual surround moves in planes orthogonal to a physical disturbance. We combined sagittal plane surface translations with visual field disturbances in 12 healthy (29–31 years) and 3 visually sensitive (27–57 years) adults. Center of pressure (COP), peak head angles, and RMS values of head motion were calculated and a 3-dimensional model of joint motion11 was developed to examine gross head motion in 3 planes. We found that subjects standing quietly in front of a visual scene translating in the sagittal plane produced significantly greater (p<0.003) head motion in yaw than when on a translating platform. However, when the platform was translated in the dark or with a visual scene rotating in roll, head motion orthogonal to the plane of platform motion significantly increased (p<0.02). Visually sensitive subjects having no history of vestibular disorder produced large, delayed compensatory head motion. Orthogonal head motions were significantly greater in visually sensitive than in healthy subjects in the dark (p<0.05) and with a stationary scene (p<0.01). We concluded that motion of the visual field can modify compensatory response kinematics of a freely moving head in planes orthogonal to the direction of a physical perturbation. These results suggest that the mechanisms controlling head orientation in space are distinct from those that control trunk orientation in space. These behaviors would have been missed if only COP data were considered. Data suggest that rehabilitation training can be enhanced by combining visual and mechanical perturbation paradigms. PMID:18162402
Satterthwaite, Theodore D.; Elliott, Mark A.; Gerraty, Raphael T.; Ruparel, Kosha; Loughead, James; Calkins, Monica E.; Eickhoff, Simon B.; Hakonarson, Hakon; Gur, Ruben C.; Gur, Raquel E.; Wolf, Daniel H.
2013-01-01
Several recent reports in large, independent samples have demonstrated the influence of motion artifact on resting-state functional connectivity MRI (rsfc-MRI). Standard rsfc-MRI preprocessing typically includes regression of confounding signals and band-pass filtering. However, substantial heterogeneity exists in how these techniques are implemented across studies, and no prior study has examined the effect of differing approaches for the control of motion-induced artifacts. To better understand how in-scanner head motion affects rsfc-MRI data, we describe the spatial, temporal, and spectral characteristics of motion artifacts in a sample of 348 adolescents. Analyses utilize a novel approach for describing head motion on a voxelwise basis. Next, we systematically evaluate the efficacy of a range of confound regression and filtering techniques for the control of motion-induced artifacts. Results reveal that the effectiveness of preprocessing procedures on the control of motion is heterogeneous, and that improved preprocessing provides a substantial benefit beyond typical procedures. These results demonstrate that the effect of motion on rsfc-MRI can be substantially attenuated through improved preprocessing procedures, but not completely removed. PMID:22926292
Dokka, Kalpana; DeAngelis, Gregory C.
2015-01-01
Humans and animals are fairly accurate in judging their direction of self-motion (i.e., heading) from optic flow when moving through a stationary environment. However, an object moving independently in the world alters the optic flow field and may bias heading perception if the visual system cannot dissociate object motion from self-motion. We investigated whether adding vestibular self-motion signals to optic flow enhances the accuracy of heading judgments in the presence of a moving object. Macaque monkeys were trained to report their heading (leftward or rightward relative to straight-forward) when self-motion was specified by vestibular, visual, or combined visual-vestibular signals, while viewing a display in which an object moved independently in the (virtual) world. The moving object induced significant biases in perceived heading when self-motion was signaled by either visual or vestibular cues alone. However, this bias was greatly reduced when visual and vestibular cues together signaled self-motion. In addition, multisensory heading discrimination thresholds measured in the presence of a moving object were largely consistent with the predictions of an optimal cue integration strategy. These findings demonstrate that multisensory cues facilitate the perceptual dissociation of self-motion and object motion, consistent with computational work that suggests that an appropriate decoding of multisensory visual-vestibular neurons can estimate heading while discounting the effects of object motion. SIGNIFICANCE STATEMENT Objects that move independently in the world alter the optic flow field and can induce errors in perceiving the direction of self-motion (heading). We show that adding vestibular (inertial) self-motion signals to optic flow almost completely eliminates the errors in perceived heading induced by an independently moving object. Furthermore, this increased accuracy occurs without a substantial loss in the precision. Our results thus demonstrate that vestibular signals play a critical role in dissociating self-motion from object motion. PMID:26446214
Less head motion during MRI under task than resting-state conditions.
Huijbers, Willem; Van Dijk, Koene R A; Boenniger, Meta M; Stirnberg, Rüdiger; Breteler, Monique M B
2017-02-15
Head motion reduces data quality of neuroimaging data. In three functional magnetic resonance imaging (MRI) experiments we demonstrate that people make less head movements under task than resting-state conditions. In Experiment 1, we observed less head motion during a memory encoding task than during the resting-state condition. In Experiment 2, using publicly shared data from the UCLA Consortium for Neuropsychiatric Phenomics LA5c Study, we again found less head motion during several active task conditions than during a resting-state condition, although some task conditions also showed comparable motion. In the healthy controls, we found more head motion in men than in women and more motion with increasing age. When comparing clinical groups, we found that patients with a clinical diagnosis of bipolar disorder, or schizophrenia, move more compared to healthy controls or patients with ADHD. Both these experiments had a fixed acquisition order across participants, and we could not rule out that a first or last scan during a session might be particularly prone to more head motion. Therefore, we conducted Experiment 3, in which we collected several task and resting-state fMRI runs with an acquisition order counter-balanced. The results of Experiment 3 show again less head motion during several task conditions than during rest. Together these experiments demonstrate that small head motions occur during MRI even with careful instruction to remain still and fixation with foam pillows, but that head motion is lower when participants are engaged in a cognitive task. These finding may inform the choice of functional runs when studying difficult-to-scan populations, such as children or certain patient populations. Our findings also indicate that differences in head motion complicate direct comparisons of measures of functional neuronal networks between task and resting-state fMRI because of potential differences in data quality. In practice, a task to reduce head motion might be especially useful when acquiring structural MRI data such as T1/T2-weighted and diffusion MRI in research and clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.
Induction and separation of motion artifacts in EEG data using a mobile phantom head device.
Oliveira, Anderson S; Schlink, Bryan R; Hairston, W David; König, Peter; Ferris, Daniel P
2016-06-01
Electroencephalography (EEG) can assess brain activity during whole-body motion in humans but head motion can induce artifacts that obfuscate electrocortical signals. Definitive solutions for removing motion artifact from EEG have yet to be found, so creating methods to assess signal processing routines for removing motion artifact are needed. We present a novel method for investigating the influence of head motion on EEG recordings as well as for assessing the efficacy of signal processing approaches intended to remove motion artifact. We used a phantom head device to mimic electrical properties of the human head with three controlled dipolar sources of electrical activity embedded in the phantom. We induced sinusoidal vertical motions on the phantom head using a custom-built platform and recorded EEG signals with three different acquisition systems while the head was both stationary and in varied motion conditions. Recordings showed up to 80% reductions in signal-to-noise ratio (SNR) and up to 3600% increases in the power spectrum as a function of motion amplitude and frequency. Independent component analysis (ICA) successfully isolated the three dipolar sources across all conditions and systems. There was a high correlation (r > 0.85) and marginal increase in the independent components' (ICs) power spectrum (∼15%) when comparing stationary and motion parameters. The SNR of the IC activation was 400%-700% higher in comparison to the channel data SNR, attenuating the effects of motion on SNR. Our results suggest that the phantom head and motion platform can be used to assess motion artifact removal algorithms and compare different EEG systems for motion artifact sensitivity. In addition, ICA is effective in isolating target electrocortical events and marginally improving SNR in relation to stationary recordings.
Induction and separation of motion artifacts in EEG data using a mobile phantom head device
NASA Astrophysics Data System (ADS)
Oliveira, Anderson S.; Schlink, Bryan R.; Hairston, W. David; König, Peter; Ferris, Daniel P.
2016-06-01
Objective. Electroencephalography (EEG) can assess brain activity during whole-body motion in humans but head motion can induce artifacts that obfuscate electrocortical signals. Definitive solutions for removing motion artifact from EEG have yet to be found, so creating methods to assess signal processing routines for removing motion artifact are needed. We present a novel method for investigating the influence of head motion on EEG recordings as well as for assessing the efficacy of signal processing approaches intended to remove motion artifact. Approach. We used a phantom head device to mimic electrical properties of the human head with three controlled dipolar sources of electrical activity embedded in the phantom. We induced sinusoidal vertical motions on the phantom head using a custom-built platform and recorded EEG signals with three different acquisition systems while the head was both stationary and in varied motion conditions. Main results. Recordings showed up to 80% reductions in signal-to-noise ratio (SNR) and up to 3600% increases in the power spectrum as a function of motion amplitude and frequency. Independent component analysis (ICA) successfully isolated the three dipolar sources across all conditions and systems. There was a high correlation (r > 0.85) and marginal increase in the independent components’ (ICs) power spectrum (˜15%) when comparing stationary and motion parameters. The SNR of the IC activation was 400%-700% higher in comparison to the channel data SNR, attenuating the effects of motion on SNR. Significance. Our results suggest that the phantom head and motion platform can be used to assess motion artifact removal algorithms and compare different EEG systems for motion artifact sensitivity. In addition, ICA is effective in isolating target electrocortical events and marginally improving SNR in relation to stationary recordings.
Spurious group differences due to head motion in a diffusion MRI study
Yendiki, Anastasia; Koldewyn, Kami; Kakunoori, Sita; Kanwisher, Nancy; Fischl, Bruce
2014-01-01
Diffusion-weighted MRI (DW-MRI) has become a popular imaging modality for probing the microstructural properties of white matter and comparing them between populations in vivo. However, the contrast in DW-MRI arises from the microscopic random motion of water molecules in brain tissues, which makes it particularly sensitive to macroscopic head motion. Although this has been known since the introduction of DW-MRI, most studies that use this modality for group comparisons do not report measures of head motion for each group and rely on registration-based correction methods that cannot eliminate the full effects of head motion on the DW-MRI contrast. In this work we use data from children with autism and typically developing children to investigate the effects of head motion on differences in anisotropy and diffusivity measures between groups. We show that group differences in head motion can induce group differences in DW-MRI measures, and that this is the case even when comparing groups that include control subjects only, where no anisotropy or diffusivity differences are expected. We also show that such effects can be more prominent in some white-matter pathways than others, and that they can be ameliorated by including motion as a nuisance regressor in the analyses. Our results demonstrate the importance of taking head motion into account in any population study where one group might exhibit more head motion than the other. PMID:24269273
Altered sensory-motor control of the head as an etiological factor in space-motion sickness
NASA Technical Reports Server (NTRS)
Lackner, J. R.; DiZio, P.
1989-01-01
Mechanical unloading during head movements in weightlessness may be an etiological factor in space-motion sickness. We simulated altered head loading on Earth without affecting vestibular stimulation by having subjects wear a weighted helmet. Eight subjects were exposed to constant velocity rotation about a vertical axis with direction reversals every 60 sec. for eight reversals with the head loaded and eight with the head unloaded. The severity of motion sickness elicited was significantly higher when the head was loaded. This suggests that altered sensory-motor control of the head is also an etiological factor in space-motion sickness.
Oh, Joo Han; Jun, Bong Jae; McGarry, Michelle H; Lee, Thay Q
2011-11-16
It is unknown at which stage of rotator cuff tear the biomechanical environment is altered. The purpose of this study was to determine if a critical rotator cuff tear stage exists that alters glenohumeral joint biomechanics throughout the rotational range of shoulder motion, and to evaluate the biomechanical effect of parascapular muscle-loading. Eight cadaver shoulders were used with a custom testing system. Four progressive rotator cuff tear stages were investigated on the basis of footprint anatomy. Three muscle-loading conditions were examined: rotator cuff only; rotator cuff with deltoid muscle; and rotator cuff, deltoid, pectoralis major, and latissimus dorsi muscles. Testing was performed in the scapular plane with 0°, 30°, and 60° of shoulder abduction. The maximum internal and external rotations were measured with 3.4 Nm of torque. The position of the humeral head apex with respect to the glenoid was calculated with use of a MicroScribe 3DLX digitizing system throughout the rotational range of motion. The abduction capability was determined as the abduction angle achieved with increasing deltoid load. Tear of the entire supraspinatus tendon significantly increased maximum external rotation and significantly decreased abduction capability with higher deltoid loads (p < 0.05). Tear of the entire supraspinatus tendon and half of the infraspinatus tendon significantly shifted the humeral head apex posteriorly at the midrange of rotation and superiorly at maximum internal rotation (p < 0.05). Loading the pectoralis major and latissimus dorsi muscles decreased the amount of humeral head elevation due to deltoid loading. Tear of the entire supraspinatus tendon was the critical stage for increasing rotational range of shoulder motion and for decreased abduction capability. Further tear progression to the infraspinatus muscle was the critical stage for significant changes in humeral head kinematics. The pectoralis major and latissimus dorsi muscles played an important role in stabilizing the humeral head as the rotator cuff tear progressed.
Neck motion due to the halo-vest in prone and supine positions.
Ivancic, Paul C; Telles, Connor J
2010-05-01
An in vitro biomechanical study of the effectiveness of halo-vest fixation. The objective was to evaluate motion of the injured cervical spine with normal halo-vest application and vest loose in the prone and supine positions. Snaking motion of the neck is defined as rotation in opposing directions throughout the cervical spine. Previous clinical studies have suggested snaking neck motion due to the halo-vest may lead to inadequate healing or nonunion. The halo-vest was applied to a Human Model of the Neck, which consisted of a cervical spine specimen mounted to the torso of an anthropometric test dummy and carrying a surrogate head. The model was transitioned from prone, to upright, to supine with the halo-vest applied normally and with the vest loose. Average peak spinal motions were computed in the prone and supine positions and contrasted with the physiologic rotation range, obtained from the intact flexibility test, and statistically compared (P < 0.05) between normal halo-vest application and vest loose. Snaking motion of the neck was observed in the prone and supine positions, consisting of extension at head/C1 and C1/2 and flexion at the inferior spinal levels. The intervertebral rotation peaks generally exceeded the physiologic range throughout the cervical spine due to the loose vest in the prone position. Significant increases in the extension peaks at head/C1 (16.9 degrees vs. 5.7 degrees) and flexion peaks at C4/5 (6.9 degrees vs. 3.6 degrees) and C7-T1 (5.2 degrees vs. 0.7 degrees) were observed in the prone position due to the loose vest, as compared to normal halo-vest application. Axial neck separation was consistently observed in the prone and supine positions. The present results, which document snaking motion of the cervical spine due to the halo-vest, indicate that an inadequately fitting or loose vest may significantly diminish its immobilization capacity leading to delayed healing or nonunion.
49 CFR 572.11 - Test conditions and instrumentation.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., December 1971, with channel classes as follows: (1) Head acceleration—Class 1000. (2) Pendulum acceleration... exceed 2g throughout the range of limb motion. (h) Performance tests are conducted at any temperature...
A method for acquiring random range uncertainty probability distributions in proton therapy
NASA Astrophysics Data System (ADS)
Holloway, S. M.; Holloway, M. D.; Thomas, S. J.
2018-01-01
In treatment planning we depend upon accurate knowledge of geometric and range uncertainties. If the uncertainty model is inaccurate then the plan will produce under-dosing of the target and/or overdosing of OAR. We aim to provide a method for which centre and site-specific population range uncertainty due to inter-fraction motion can be quantified to improve the uncertainty model in proton treatment planning. Daily volumetric MVCT data from previously treated radiotherapy patients has been used to investigate inter-fraction changes to water equivalent path-length (WEPL). Daily image-guidance scans were carried out for each patient and corrected for changes in CTV position (using rigid transformations). An effective depth algorithm was used to determine residual range changes, after corrections had been applied, throughout the treatment by comparing WEPL within the CTV at each fraction for several beam angles. As a proof of principle this method was used to quantify uncertainties for inter-fraction range changes for a sample of head and neck patients of Σ=3.39 mm, σ = 4.72 mm and overall mean = -1.82 mm. For prostate Σ=5.64 mm, σ = 5.91 mm and overall mean = 0.98 mm. The choice of beam angle for head and neck did not affect the inter-fraction range error significantly; however this was not the same for prostate. Greater range changes were seen using a lateral beam compared to an anterior beam for prostate due to relative motion of the prostate and femoral heads. A method has been developed to quantify population range changes due to inter-fraction motion that can be adapted for the clinic. The results of this work highlight the importance of robust planning and analysis in proton therapy. Such information could be used in robust optimisation algorithms or treatment plan robustness analysis. Such knowledge will aid in establishing beam start conditions at planning and for establishing adaptive planning protocols.
Texting and Walking: Strategies for Postural Control and Implications for Safety
Schabrun, Siobhan M.; van den Hoorn, Wolbert; Moorcroft, Alison; Greenland, Cameron; Hodges, Paul W.
2014-01-01
There are concerns about the safety of texting while walking. Although evidence of negative effects of mobile phone use on gait is scarce, cognitive distraction, altered mechanical demands, and the reduced visual field associated with texting are likely to have an impact. In 26 healthy individuals we examined the effect of mobile phone use on gait. Individuals walked at a comfortable pace in a straight line over a distance of ∼8.5 m while; 1) walking without the use of a phone, 2) reading text on a mobile phone, or 3) typing text on a mobile phone. Gait performance was evaluated using a three-dimensional movement analysis system. In comparison with normal waking, when participants read or wrote text messages they walked with: greater absolute lateral foot position from one stride to the next; slower speed; greater rotation range of motion (ROM) of the head with respect to global space; the head held in a flexed position; more in-phase motion of the thorax and head in all planes, less motion between thorax and head (neck ROM); and more tightly organized coordination in lateral flexion and rotation directions. While writing text, participants walked slower, deviated more from a straight line and used less neck ROM than reading text. Although the arms and head moved with the thorax to reduce relative motion of the phone and facilitate reading and texting, movement of the head in global space increased and this could negatively impact the balance system. Texting, and to a lesser extent reading, modify gait performance. Texting or reading on a mobile phone may pose an additional risk to safety for pedestrians navigating obstacles or crossing the road. PMID:24465402
Cervical isometric strength and range of motion of elite rugby union players: a cohort study
2014-01-01
Background Head and neck injury is relatively common in Rugby Union. Despite this, strength and range-of-motion characteristics of the cervical spine are poorly characterised. The aim of this study was to provide data on the strength and range-of-motion of the cervical spine of professional rugby players to guide clinical rehabilitation. Methods A cohort study was performed evaluating 27 players from a single UK professional rugby club. Cervical isometric strength and range-of-motion were assessed in 3 planes of reference. Anthropometric data was collected and multivariate regression modelling performed with a view to predicting cervical isometric strength. Results Largest forces were generated in extension, with broadly equal isometric side flexion forces at around 90% of extension values. The forwards generated significantly more force than the backline in all parameters bar flexion. The forwards had substantially reduced cervical range-of-motion and larger body mass, with differences observed in height, weight, neck circumference and chest circumference (p < 0.002). Neck circumference was the sole predictor of isometric extension (adjusted R2 = 30.34). Conclusion Rehabilitative training programs aim to restore individuals to pre-injury status. This work provides reference ranges for the strength and range of motion of the cervical spine of current elite level rugby players. PMID:25120916
Cervical isometric strength and range of motion of elite rugby union players: a cohort study.
Hamilton, David F; Gatherer, Don
2014-01-01
Head and neck injury is relatively common in Rugby Union. Despite this, strength and range-of-motion characteristics of the cervical spine are poorly characterised. The aim of this study was to provide data on the strength and range-of-motion of the cervical spine of professional rugby players to guide clinical rehabilitation. A cohort study was performed evaluating 27 players from a single UK professional rugby club. Cervical isometric strength and range-of-motion were assessed in 3 planes of reference. Anthropometric data was collected and multivariate regression modelling performed with a view to predicting cervical isometric strength. Largest forces were generated in extension, with broadly equal isometric side flexion forces at around 90% of extension values. The forwards generated significantly more force than the backline in all parameters bar flexion. The forwards had substantially reduced cervical range-of-motion and larger body mass, with differences observed in height, weight, neck circumference and chest circumference (p < 0.002). Neck circumference was the sole predictor of isometric extension (adjusted R(2) = 30.34). Rehabilitative training programs aim to restore individuals to pre-injury status. This work provides reference ranges for the strength and range of motion of the cervical spine of current elite level rugby players.
Multimodal integration in rostral fastigial nucleus provides an estimate of body movement
Brooks, Jessica X.; Cullen, Kathleen E.
2012-01-01
The ability to accurately control posture and perceive self motion and spatial orientation requires knowledge of both the motion of the head and body. However, while the vestibular sensors and nuclei directly encode head motion, no sensors directly encode body motion. Instead, the convergence of vestibular and neck proprioceptive inputs during self-motion is generally believed to underlie the ability to compute body motion. Here, we provide evidence that the brain explicitly computes an internal estimate of body motion at the level of single cerebellar neurons. Neuronal responses were recorded from the rostral fastigial nucleus, the most medial of the deep cerebellar nuclei, during whole-body, body-under-head, and head-on-body rotations. We found that approximately half of the neurons encoded the motion of the body-in-space, while the other half encoded the motion of the head-in-space in a manner similar to neurons in the vestibular nuclei. Notably, neurons encoding body motion responded to both vestibular and proprioceptive stimulation (accordingly termed bimodal neurons). In contrast, neurons encoding head motion were only sensitive to vestibular inputs (accordingly termed unimodal neurons). Comparison of the proprioceptive and vestibular responses of bimodal neurons further revealed similar tuning in response to changes in head-on-body position. We propose that the similarity in nonlinear processing of vestibular and proprioceptive signals underlies the accurate computation of body motion. Furthermore, the same neurons that encode body motion (i.e., bimodal neurons) most likely encode vestibular signals in a body referenced coordinate frame, since the integration of proprioceptive and vestibular information is required for both computations. PMID:19710303
Screw fixation versus arthroplasty versus plate fixation for 3-part radial head fractures.
Wu, P H; Shen, L; Chee, Y H
2016-04-01
To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with a 2-mm Synthes plate (n=12) for 3-part Mason types III or IV radial head and neck fracture were reviewed. Treatment option was decided by the surgeon based on the presence of associated injury, neurovascular deficit, and the Mason classification. Bone union, callus formation, and complications (such as heterotopic ossification, malunion, and nonunion) were assessed by an independent registrar or consultant using radiographs. The Mayo Elbow Performance Score and range of motion were assessed by an independent physiotherapist. The median age of the 3 groups were comparable. Associated injuries were most common in patients with arthroplasty, followed by screw fixation and plate fixation (61.5% vs. 50% vs. 33%, p=0.54). The median time to bone union was shorter after screw fixation than plate fixation (55 vs. 86 days, p=0.05). No patient with screw fixation had nonunion, but 4 patients with plate fixation had nonunion. The 3 groups were comparable in terms of the mean Mayo Elbow Performance Score (p=0.56) and the mean range of motion (p=0.45). The complication rate was highest after plate fixation, followed by screw fixation and arthroplasty (50% vs. 18.8% vs. 15.4%, p=0.048). Excluding 20 patients with associated injuries (8 in screw fixation, 8 in arthroplasty, and 4 in plate fixation), the 3 groups were comparable in terms of the median time to bone union (p=0.109), mean Mayo Elbow Performance Score (p=0.260), mean range of motion (p=0.162), and complication rate (p=0.096). Headless compression screw fixation is a viable option for 3-part radial head fracture. It achieves earlier bone union with fewer complications.
49 CFR 572.21 - Test conditions and instrumentation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Recommended Practice J211a, December 1971, with channel classes as follows: (1) Head acceleration—Class 1000... exceed 2g throughout the range of limb motion. (g) Performance tests are conducted at any temperature...
Recommended minimal cockpit head motion box dimensions
DOT National Transportation Integrated Search
2001-09-26
This memo provides recommendations for the dimensions of the minimal CHMB based on a study of pilot head motion in actual flight. These recommended dimensions should accommodate the vast majority of the targeted head motion exhibited by the vast majo...
Schindler, Andreas; Bartels, Andreas
2018-05-15
Our phenomenological experience of the stable world is maintained by continuous integration of visual self-motion with extra-retinal signals. However, due to conventional constraints of fMRI acquisition in humans, neural responses to visuo-vestibular integration have only been studied using artificial stimuli, in the absence of voluntary head-motion. We here circumvented these limitations and let participants to move their heads during scanning. The slow dynamics of the BOLD signal allowed us to acquire neural signal related to head motion after the observer's head was stabilized by inflatable aircushions. Visual stimuli were presented on head-fixed display goggles and updated in real time as a function of head-motion that was tracked using an external camera. Two conditions simulated forward translation of the participant. During physical head rotation, the congruent condition simulated a stable world, whereas the incongruent condition added arbitrary lateral motion. Importantly, both conditions were precisely matched in visual properties and head-rotation. By comparing congruent with incongruent conditions we found evidence consistent with the multi-modal integration of visual cues with head motion into a coherent "stable world" percept in the parietal operculum and in an anterior part of parieto-insular cortex (aPIC). In the visual motion network, human regions MST, a dorsal part of VIP, the cingulate sulcus visual area (CSv) and a region in precuneus (Pc) showed differential responses to the same contrast. The results demonstrate for the first time neural multimodal interactions between precisely matched congruent versus incongruent visual and non-visual cues during physical head-movement in the human brain. The methodological approach opens the path to a new class of fMRI studies with unprecedented temporal and spatial control over visuo-vestibular stimulation. Copyright © 2018 Elsevier Inc. All rights reserved.
Heading Tuning in Macaque Area V6.
Fan, Reuben H; Liu, Sheng; DeAngelis, Gregory C; Angelaki, Dora E
2015-12-16
Cortical areas, such as the dorsal subdivision of the medial superior temporal area (MSTd) and the ventral intraparietal area (VIP), have been shown to integrate visual and vestibular self-motion signals. Area V6 is interconnected with areas MSTd and VIP, allowing for the possibility that V6 also integrates visual and vestibular self-motion cues. An alternative hypothesis in the literature is that V6 does not use these sensory signals to compute heading but instead discounts self-motion signals to represent object motion. However, the responses of V6 neurons to visual and vestibular self-motion cues have never been studied, thus leaving the functional roles of V6 unclear. We used a virtual reality system to examine the 3D heading tuning of macaque V6 neurons in response to optic flow and inertial motion stimuli. We found that the majority of V6 neurons are selective for heading defined by optic flow. However, unlike areas MSTd and VIP, V6 neurons are almost universally unresponsive to inertial motion in the absence of optic flow. We also explored the spatial reference frames of heading signals in V6 by measuring heading tuning for different eye positions, and we found that the visual heading tuning of most V6 cells was eye-centered. Similar to areas MSTd and VIP, the population of V6 neurons was best able to discriminate small variations in heading around forward and backward headings. Our findings support the idea that V6 is involved primarily in processing visual motion signals and does not appear to play a role in visual-vestibular integration for self-motion perception. To understand how we successfully navigate our world, it is important to understand which parts of the brain process cues used to perceive our direction of self-motion (i.e., heading). Cortical area V6 has been implicated in heading computations based on human neuroimaging data, but direct measurements of heading selectivity in individual V6 neurons have been lacking. We provide the first demonstration that V6 neurons carry 3D visual heading signals, which are represented in an eye-centered reference frame. In contrast, we found almost no evidence for vestibular heading signals in V6, indicating that V6 is unlikely to contribute to multisensory integration of heading signals, unlike other cortical areas. These findings provide important constraints on the roles of V6 in self-motion perception. Copyright © 2015 the authors 0270-6474/15/3516303-12$15.00/0.
Adaptive algorithm of magnetic heading detection
NASA Astrophysics Data System (ADS)
Liu, Gong-Xu; Shi, Ling-Feng
2017-11-01
Magnetic data obtained from a magnetic sensor usually fluctuate in a certain range, which makes it difficult to estimate the magnetic heading accurately. In fact, magnetic heading information is usually submerged in noise because of all kinds of electromagnetic interference and the diversity of the pedestrian’s motion states. In order to solve this problem, a new adaptive algorithm based on the (typically) right-angled corridors of a building or residential buildings is put forward to process heading information. First, a 3D indoor localization platform is set up based on MPU9250. Then, several groups of data are measured by changing the experimental environment and pedestrian’s motion pace. The raw data from the attached inertial measurement unit are calibrated and arranged into a time-stamped array and written to a data file. Later, the data file is imported into MATLAB for processing and analysis using the proposed adaptive algorithm. Finally, the algorithm is verified by comparison with the existing algorithm. The experimental results show that the algorithm has strong robustness and good fault tolerance, which can detect the heading information accurately and in real-time.
Using EMG to anticipate head motion for virtual-environment applications
NASA Technical Reports Server (NTRS)
Barniv, Yair; Aguilar, Mario; Hasanbelliu, Erion
2005-01-01
In virtual environment (VE) applications, where virtual objects are presented in a see-through head-mounted display, virtual images must be continuously stabilized in space in response to user's head motion. Time delays in head-motion compensation cause virtual objects to "swim" around instead of being stable in space which results in misalignment errors when overlaying virtual and real objects. Visual update delays are a critical technical obstacle for implementing head-mounted displays in applications such as battlefield simulation/training, telerobotics, and telemedicine. Head motion is currently measurable by a head-mounted 6-degrees-of-freedom inertial measurement unit. However, even given this information, overall VE-system latencies cannot be reduced under about 25 ms. We present a novel approach to eliminating latencies, which is premised on the fact that myoelectric signals from a muscle precede its exertion of force, thereby limb or head acceleration. We thus suggest utilizing neck-muscles' myoelectric signals to anticipate head motion. We trained a neural network to map such signals onto equivalent time-advanced inertial outputs. The resulting network can achieve time advances of up to 70 ms.
Using EMG to anticipate head motion for virtual-environment applications.
Barniv, Yair; Aguilar, Mario; Hasanbelliu, Erion
2005-06-01
In virtual environment (VE) applications, where virtual objects are presented in a see-through head-mounted display, virtual images must be continuously stabilized in space in response to user's head motion. Time delays in head-motion compensation cause virtual objects to "swim" around instead of being stable in space which results in misalignment errors when overlaying virtual and real objects. Visual update delays are a critical technical obstacle for implementing head-mounted displays in applications such as battlefield simulation/training, telerobotics, and telemedicine. Head motion is currently measurable by a head-mounted 6-degrees-of-freedom inertial measurement unit. However, even given this information, overall VE-system latencies cannot be reduced under about 25 ms. We present a novel approach to eliminating latencies, which is premised on the fact that myoelectric signals from a muscle precede its exertion of force, thereby limb or head acceleration. We thus suggest utilizing neck-muscles' myoelectric signals to anticipate head motion. We trained a neural network to map such signals onto equivalent time-advanced inertial outputs. The resulting network can achieve time advances of up to 70 ms.
Interpersonal Coordination of Head Motion in Distressed Couples
Hammal, Zakia; Cohn, Jeffrey F.; George, David T.
2015-01-01
In automatic emotional expression analysis, head motion has been considered mostly a nuisance variable, something to control when extracting features for action unit or expression detection. As an initial step toward understanding the contribution of head motion to emotion communication, we investigated the interpersonal coordination of rigid head motion in intimate couples with a history of interpersonal violence. Episodes of conflict and non-conflict were elicited in dyadic interaction tasks and validated using linguistic criteria. Head motion parameters were analyzed using Student’s paired t-tests; actor-partner analyses to model mutual influence within couples; and windowed cross-correlation to reveal dynamics of change in direction of influence over time. Partners’ RMS angular displacement for yaw and RMS angular velocity for pitch and yaw each demonstrated strong mutual influence between partners. Partners’ RMS angular displacement for pitch was higher during conflict. In both conflict and non-conflict, head angular displacement and angular velocity for pitch and yaw were strongly correlated, with frequent shifts in lead-lag relationships. The overall amount of coordination between partners’ head movement was more highly correlated during non-conflict compared with conflict interaction. While conflict increased head motion, it served to attenuate interpersonal coordination. PMID:26167256
NASA Technical Reports Server (NTRS)
Lackner, James R.; Graybiel, Ashton
1987-01-01
Astronauts report that head movements in flight tend to bring on symptoms of space motion sickness (SMS). The effects of head movements in pitch, yaw, and roll (made both with normal vision and with eyes occluded) on susceptibility to motion sickness in the zero G phase of parabolic flight maneuvers were evaluated. The findings are clear-cut: pitch head movements are most provocative, yaw least provocative, and roll intermediate. These experiments suggest that SMS is not a unique nosological entity, but is the consequence of exposure to nonterrestrial force levels. Head movements during departures in either direction from 1 G elicit symptoms.
Villafañe, Jorge Hugo; Pillastrini, Paolo; Borboni, Alberto
2013-09-01
The purpose of this case report is to describe a therapeutic intervention for peroneal nerve paralysis involving the sciatic nerve. A 24-year-old man presented with peroneal nerve paralysis with decreased sensation, severe pain in the popliteal fossa, and steppage gait, which occurred 3 days prior to the consultation. Magnetic resonance imaging and electromyography confirmed lumbar disk herniation with sciatic common peroneal nerve entrapment in the popliteal fossa. A combined treatment protocol of spinal and fibular head manipulation and neurodynamic mobilization including soft tissue work of the psoas and hamstring muscles was performed. Outcome measures were assessed at pretreatment, 1 week posttreatment, and 3-month follow-up and included numeric pain rating scale, range of motion, pressure pain threshold, and manual muscle testing. Treatment interventions were applied for 3 sessions over a period of 1 week. Results showed reduction of the patient's subjective pain and considerable improvement in range of motion, strength, and sensation in his left foot, which was restored to full function. A combined program of spinal and fibular head manipulation and neurodynamic mobilization reduced pain, increased range of motion and strength, and restored full function to the left leg in this patient who had severe functional impairment related to a compressed left common peroneal nerve.
Farhoudi, Hamidreza; Fallahnezhad, Khosro; Oskouei, Reza H; Taylor, Mark
2017-11-01
This paper investigates the mechanical response of a modular head-neck interface of hip joint implants under realistic loads of level walking. The realistic loads of the walking activity consist of three dimensional gait forces and the associated frictional moments. These forces and moments were extracted for a 32mm metal-on-metal bearing couple. A previously reported geometry of a modular CoCr/CoCr head-neck interface with a proximal contact was used for this investigation. An explicit finite element analysis was performed to investigate the interface mechanical responses. To study the level of contribution and also the effect of superposition of the load components, three different scenarios of loading were studied: gait forces only, frictional moments only, and combined gait forces and frictional moments. Stress field, micro-motions, shear stresses and fretting work at the contacting nodes of the interface were analysed. Gait forces only were found to significantly influence the mechanical environment of the head-neck interface by temporarily extending the contacting area (8.43% of initially non-contacting surface nodes temporarily came into contact), and therefore changing the stress field and resultant micro-motions during the gait cycle. The frictional moments only did not cause considerable changes in the mechanical response of the interface (only 0.27% of the non-contacting surface nodes temporarily came into contact). However, when superposed with the gait forces, the mechanical response of the interface, particularly micro-motions and fretting work, changed compared to the forces only case. The normal contact stresses and micro-motions obtained from this realistic load-controlled study were typically in the range of 0-275MPa and 0-38µm, respectively. These ranges were found comparable to previous experimental displacement-controlled pin/cylinder-on-disk fretting corrosion studies. Copyright © 2017 Elsevier Ltd. All rights reserved.
de Oliveira, Lilian Becerra; Cajaíba, Franklin; Costa, Wesley; Rocabado, Mariano; Lazo-Osório, Rodrigo; Ribeiro, Sanzia
2012-01-01
There are several instruments of evaluation of the craniocervical equilibrium; the most reliable are the radiographies. This study used the cephalometric analysis of Rocabado to measure the sensibility and specificity of the Cervical Range of Motion (CROM), a goniometer designed to assess cervical movements in degrees, and measure the forward head position in centimeters. This instrument frequently used, has been tested as a reliable instrument to evaluate the cervical movements but not the forward head. The sample consisted of 30 volunteers, 18 females, 12 males, mean age of 24.63 years. All participants were evaluated with CROM and radiographies in the resting head position and in erect head position. The values considered by the cephalometry consisted in the angle made between the McGregor plane and the vertical line formed by the base of the odontoid process to its apex; the posterior space between C0-C1 and C1-C2 and the hyoid triangle. 30% of the subjects had forward head posture, according to de cephalometry of Rocabado (decreased space between C0-C1, C1-C2) and 43,3% according to CROM. 16,6% had decreased posterior-inferior angle, and 13% had the hyoid triangle facing up. ROC curve of identifying forward head posture yielded area under the curve of 0,778 (95% confidence interval 0,596-0,960). The sensibility of CROM was: 77%. The specificity 71%. This study suggests that CROM has a moderate sensibility and specificity, useful for clinic use, but not for research.
Evaluation of a video-based head motion tracking system for dedicated brain PET
NASA Astrophysics Data System (ADS)
Anishchenko, S.; Beylin, D.; Stepanov, P.; Stepanov, A.; Weinberg, I. N.; Schaeffer, S.; Zavarzin, V.; Shaposhnikov, D.; Smith, M. F.
2015-03-01
Unintentional head motion during Positron Emission Tomography (PET) data acquisition can degrade PET image quality and lead to artifacts. Poor patient compliance, head tremor, and coughing are examples of movement sources. Head motion due to patient non-compliance can be an issue with the rise of amyloid brain PET in dementia patients. To preserve PET image resolution and quantitative accuracy, head motion can be tracked and corrected in the image reconstruction algorithm. While fiducial markers can be used, a contactless approach is preferable. A video-based head motion tracking system for a dedicated portable brain PET scanner was developed. Four wide-angle cameras organized in two stereo pairs are used for capturing video of the patient's head during the PET data acquisition. Facial points are automatically tracked and used to determine the six degree of freedom head pose as a function of time. The presented work evaluated the newly designed tracking system using a head phantom and a moving American College of Radiology (ACR) phantom. The mean video-tracking error was 0.99±0.90 mm relative to the magnetic tracking device used as ground truth. Qualitative evaluation with the ACR phantom shows the advantage of the motion tracking application. The developed system is able to perform tracking with accuracy close to millimeter and can help to preserve resolution of brain PET images in presence of movements.
Specialization of Perceptual Processes.
1994-09-01
population rose and fell, furniture was rearranged, a small mountain range was built in part of the lab (really), carpets were shampooed , and oce lighting...common task is the tracking of moving objects. Coombs [22] implemented a system 44 for xating and tracking objects using a stereo eye/ head system...be a person (person?). Finally, a motion unit is used to detect foot gestures. A pair of nod-of-the- head detectors were implemented and tested, but
Ash, April; Palmisano, Stephen
2012-01-01
We examined the vection induced by consistent and conflicting multisensory information about self-motion. Observers viewed displays simulating constant-velocity self-motion in depth while physically oscillating their heads left-right or back-forth in time with a metronome. Their tracked head movements were either ignored or incorporated directly into the self-motion display (as an added simulated self-acceleration). When this head oscillation was updated into displays, sensory conflict was generated by simulating oscillation along: (i) an orthogonal axis to the head movement; or (ii) the same axis, but in a non-ecological direction. Simulated head oscillation always produced stronger vection than 'no display oscillation'--even when the axis/direction of this display motion was inconsistent with the physical head motion. When head-and-display oscillation occurred along the same axis: (i) consistent (in-phase) horizontal display oscillation produced stronger vection than conflicting (out-of-phase) horizontal display oscillation; however, (ii) consistent and conflicting depth oscillation conditions did not induce significantly different vection. Overall, orthogonal-axis oscillation was found to produce very similar vection to same-axis oscillation. Thus, we conclude that while vection appears to be very robust to sensory conflict, there are situations where sensory consistency improves vection.
Li, Guang; Lovelock, D Michael; Mechalakos, James; Rao, Shyam; Della-Biancia, Cesar; Amols, Howard; Lee, Nancy
2013-09-06
To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full-head mask.
A head motion estimation algorithm for motion artifact correction in dental CT imaging
NASA Astrophysics Data System (ADS)
Hernandez, Daniel; Elsayed Eldib, Mohamed; Hegazy, Mohamed A. A.; Hye Cho, Myung; Cho, Min Hyoung; Lee, Soo Yeol
2018-03-01
A small head motion of the patient can compromise the image quality in a dental CT, in which a slow cone-beam scan is adopted. We introduce a retrospective head motion estimation method by which we can estimate the motion waveform from the projection images without employing any external motion monitoring devices. We compute the cross-correlation between every two successive projection images, which results in a sinusoid-like displacement curve over the projection view when there is no patient motion. However, the displacement curve deviates from the sinusoid-like form when patient motion occurs. We develop a method to estimate the motion waveform with a single parameter derived from the displacement curve with aid of image entropy minimization. To verify the motion estimation method, we use a lab-built micro-CT that can emulate major head motions during dental CT scans, such as tilting and nodding, in a controlled way. We find that the estimated motion waveform conforms well to the actual motion waveform. To further verify the motion estimation method, we correct the motion artifacts with the estimated motion waveform. After motion artifact correction, the corrected images look almost identical to the reference images, with structural similarity index values greater than 0.81 in the phantom and rat imaging studies.
Lee, Kyung-Min; Song, Jin-Myoung; Cho, Jin-Hyoung; Hwang, Hyeon-Shik
2016-01-01
The purpose of this study was to investigate the influence of head motion on the accuracy of three-dimensional (3D) reconstruction with cone-beam computed tomography (CBCT) scan. Fifteen dry skulls were incorporated into a motion controller which simulated four types of head motion during CBCT scan: 2 horizontal rotations (to the right/to the left) and 2 vertical rotations (upward/downward). Each movement was triggered to occur at the start of the scan for 1 second by remote control. Four maxillofacial surface models with head motion and one control surface model without motion were obtained for each skull. Nine landmarks were identified on the five maxillofacial surface models for each skull, and landmark identification errors were compared between the control model and each of the models with head motion. Rendered surface models with head motion were similar to the control model in appearance; however, the landmark identification errors showed larger values in models with head motion than in the control. In particular, the Porion in the horizontal rotation models presented statistically significant differences (P < .05). Statistically significant difference in the errors between the right and left side landmark was present in the left side rotation which was opposite direction to the scanner rotation (P < .05). Patient movement during CBCT scan might cause landmark identification errors on the 3D surface model in relation to the direction of the scanner rotation. Clinicians should take this into consideration to prevent patient movement during CBCT scan, particularly horizontal movement.
Cervical motion assessment using virtual reality.
Sarig-Bahat, Hilla; Weiss, Patrice L; Laufer, Yocheved
2009-05-01
Repeated measures of cervical motion in asymptomatic subjects. To introduce a virtual reality (VR)-based assessment of cervical range of motion (ROM); to establish inter and intratester reliability of the VR-based assessment in comparison with conventional assessment in asymptomatic individuals; and to evaluate the effect of a single VR session on cervical ROM. Cervical ROM and clinical issues related to neck pain is frequently studied. A wide variety of methods is available for evaluation of cervical motion. To date, most methods rely on voluntary responses to an assessor's instructions. However, in day-to-day life, head movement is generally an involuntary response to multiple stimuli. Therefore, there is a need for a more functional assessment method, using sensory stimuli to elicit spontaneous neck motion. VR attributes may provide a methodology for achieving this goal. A novel method was developed for cervical motion assessment utilizing an electromagnetic tracking system and a VR game scenario displayed via a head mounted device. Thirty asymptomatic participants were assessed by both conventional and VR-based methods. Inter and intratester repeatability analyses were performed. The effect of a single VR session on ROM was evaluated. Both assessments showed non-biased results between tests and between testers (P > 0.1). Full-cycle repeatability coefficients ranged between 15.0 degrees and 29.2 degrees with smaller values for rotation and for the VR assessment. A single VR session significantly increased ROM, with largest effect found in the rotation direction. Inter and intratester reliability was supported for both the VR-based and the conventional methods. Results suggest better repeatability for the VR method, with rotation being more precise than flexion/extension. A single VR session was found to be effective in increasing cervical motion, possibly due to its motivating effect.
Rehabilitation of Dysphagia Following Head and Neck Cancer
Pauloski, Barbara R.
2008-01-01
SYNOPSIS Patients with cancers of the oral cavity, pharynx or larynx may be treated with surgery, radiotherapy, chemotherapy, or a combination of these modalities. Each treatment type may have a negative impact on posttreatment swallowing function; these effects are presented in this chapter. The clinician has a number of rehabilitative procedures available to reduce or eliminate swallowing disorders in patients treated for cancer of the head and neck. The various procedures--including postures, maneuvers, modifications to bolus volume and viscosity, range of motion exercises, and strengthening exercises--and their efficacy in treated head and neck cancer patients are discussed. PMID:18940647
Riboldi, Marco; Gianoli, Chiara; Chirvase, Cezarina I.; Villa, Gaetano; Paganelli, Chiara; Summers, Paul E.; Tagaste, Barbara; Pella, Andrea; Fossati, Piero; Ciocca, Mario; Baroni, Guido; Valvo, Francesca; Orecchia, Roberto
2016-01-01
Particle therapy (PT) has shown positive therapeutic results in local control of locally advanced pancreatic lesions. PT effectiveness is highly influenced by target localization accuracy both in space, since the pancreas is located in proximity to radiosensitive vital organs, and in time as it is subject to substantial breathing‐related motion. The purpose of this preliminary study was to quantify pancreas range of motion under typical PT treatment conditions. Three common immobilization devices (vacuum cushion, thermoplastic mask, and compressor belt) were evaluated on five male patients in prone and supine positions. Retrospective four‐dimensional magnetic resonance imaging data were reconstructed for each condition and the pancreas was manually segmented on each of six breathing phases. A k‐means algorithm was then applied on the manually segmented map in order to obtain clusters representative of the three pancreas segments: head, body, and tail. Centers of mass (COM) for the pancreas and its segments were computed, as well as their displacements with respect to a reference breathing phase (beginning exhalation). The median three‐dimensional COM displacements were in the range of 3 mm. Latero–lateral and superior–inferior directions had a higher range of motion than the anterior–posterior direction. Motion analysis of the pancreas segments showed slightly lower COM displacements for the head cluster compared to the tail cluster, especially in prone position. Statistically significant differences were found within patients among the investigated setups. Hence a patient‐specific approach, rather than a general strategy, is suggested to define the optimal treatment setup in the frame of a millimeter positioning accuracy. PACS number(s): 87.55.‐x, 87.57.nm, 87.61 PMID:27685119
NASA Astrophysics Data System (ADS)
Trew, Noel; Linn, Aaron; Nelson, Zac; Burnett, Greg; Sedillo, Mike
2012-06-01
Today, warfighters are burdened by a web of cables linking technologies that span the head and torso regions of the body. These cables help to provide interoperability between helmet-worn peripherals such as head mounted displays (HMDs), cameras, and communication equipment with chest-worn computers and radios. Although promoting enhanced capabilities, this cabling also poses snag hazards and makes it difficult for the warfighter to extricate himself from his kit when necessary. A newly developed wireless personal area network (WPAN), one that uses optical transceivers, may prove to be an acceptable alternative to traditional cabling. Researchers at the Air Force Research Laboratory's 711th Human Performance Wing are exploring how best to mount the WPAN transceivers to the body in order to facilitate unimpeded data transfer while also maintaining the operator's natural range of motion. This report describes the two-step research process used to identify the performance limitations and usability of a body-worn optical wireless system. Firstly, researchers characterized the field of view for the current generation of optical WPAN transceivers. Then, this field of view was compared with anthropometric data describing the range of motion of the cervical vertebrae to see if the data link would be lost at the extremes of an operator's head movement. Finally, this report includes an additional discussion of other possible military applications for an optical WPAN.
Neck muscle activation and head postures in common high performance aerial combat maneuvers.
Netto, Kevin J; Burnett, Angus F
2006-10-01
Neck injuries are common in high performance combat pilots and have been attributed to high gravitational forces and the non-neutral head postures adopted during aerial combat maneuvers. There is still little known about the pathomechanics of these injuries. Six Royal Australian Air Force Hawk pilots flew a sortie that included combinations of three +Gz levels (1, 3, and 5) and four head postures (Neutral, Turn, Extension, and Check-6). Surface electromyography from neck and shoulder muscles was recorded in flight. Three-dimensional measures of head postures adopted in flight were estimated postflight with respect to end-range of the cervical spine using an electromagnetic tracking device. Mean muscle activation increased significantly with both increasing +Gz and non-neutral head postures. Check-6 at +5 Gz (mean activation of all muscles = 51% MVIC) elicited significantly greater muscle activation in most muscles when compared with Neutral, Extension, and Turn head postures. High levels of muscle co-contraction were evident in high acceleration and non-neutral head postures. Head kinematics showed Check-6 was closest to end-range in any movement plane (86% ROM in rotation) and produced the greatest magnitude of rotation in other planes. Turn and Extension showed a large magnitude of rotation with reference to end-range in the primary plane of motion but displayed smaller rotations in other planes. High levels of neck muscle activation and co-contraction due to high +Gz and head postures close to end range were evident in this study, suggesting the major influence of these factors on the pathomechanics of neck injuries in high performance combat pilots.
NASA Technical Reports Server (NTRS)
Han, Yanning H.
2006-01-01
We studied horizontal eye movements induced by en-bloc yaw rotation, over a frequency range 0.2 - 2.8 Hz, in 10 normal human subjects as they monocularly viewed a target located at their near point of focus. We measured gain and phase relationships between eye-in-head velocity and head velocity when the near target was either earth-fixed or head-fixed. During viewing of the earth-fixed near target, median gain was 1.49 (range 1.24 - 1.87) at 0.2 Hz for the group of subjects, but declined at higher frequencies, so that at 2.8 Hz median gain was 1.08 (range 0.68 - 1.67). During viewing of the head-fixed near target , median gain was 0.03 (range 0.01 - 0.10) at 0.2 Hz for the group of subjects, but increased at higher frequencies, so that at 2.8 Hz median gain was 0.71 (range 0.28 - 0.94). We estimated the vestibular contribution to these responses vestibulo-ocular reflex gain (Gvor) by applying transient head perturbations (peak acceleration> 1,000 deg/s(exp 2)) during sinusoidal rotation under the two viewing conditions. Median Gvor, estimated < 70ms after the onset of head perturbation, was 0.98 (range 0.39 - 1.42) while viewing the earth-fixed near target, and 0.97 (range 0.37 - 1.33) while viewing the head-fixed near target. For the group of subjects, 9 out of 10 subjects showed no significant difference of Gvor between the two viewing conditions ( p > 0.053 ) at all test frequencies. Since Gvor accounted for only -73% of the overall response gain during viewing of the earth-fixed target, we investigated the relative contributions of non-vestibular factors. When subjects viewed the earth-fixed target under strobe illumination, to eliminate retinal image slip information, the gain of compensatory eye movements declined compared with viewing in ambient room light. During sum-of-sine head rotations, while viewing the earth-fixed target, to Han et al./VOR during near-viewing minimize contributions from predictive mechanisms, gain also declined Nonetheless, simple superposition of smooth-pursuit tracking of sinusoidal target motion could not fully account for the overall response at higher frequencies, suggesting other nonvestibular contributions. During binocular viewing conditions when vergence angle was significantly greater than monocular viewing (p < 0.00l), the gain of compensatory eye movements did not show proportional change; indeed, gain could not be correlated with vergence angle during monocular or binocular viewing. We conclude that several separate factors contribute to generate eye rotations during sinusoidal yaw head rotations while viewing a near target; these include the VOR, visual-tracking eye movements that utilize retinal image motion, predictive eye movements and, possibly, other unidentified non-vestibular factors. For these experiments, vergence was not an important determinant of response gam.
The moving minimum audible angle is smaller during self motion than during source motion
Brimijoin, W. Owen; Akeroyd, Michael A.
2014-01-01
We are rarely perfectly still: our heads rotate in three axes and move in three dimensions, constantly varying the spectral and binaural cues at the ear drums. In spite of this motion, static sound sources in the world are typically perceived as stable objects. This argues that the auditory system—in a manner not unlike the vestibulo-ocular reflex—works to compensate for self motion and stabilize our sensory representation of the world. We tested a prediction arising from this postulate: that self motion should be processed more accurately than source motion. We used an infrared motion tracking system to measure head angle, and real-time interpolation of head related impulse responses to create “head-stabilized” signals that appeared to remain fixed in space as the head turned. After being presented with pairs of simultaneous signals consisting of a man and a woman speaking a snippet of speech, normal and hearing impaired listeners were asked to report whether the female voice was to the left or the right of the male voice. In this way we measured the moving minimum audible angle (MMAA). This measurement was made while listeners were asked to turn their heads back and forth between ± 15° and the signals were stabilized in space. After this “self-motion” condition we measured MMAA in a second “source-motion” condition when listeners remained still and the virtual locations of the signals were moved using the trajectories from the first condition. For both normal and hearing impaired listeners, we found that the MMAA for signals moving relative to the head was ~1–2° smaller when the movement was the result of self motion than when it was the result of source motion, even though the motion with respect to the head was identical. These results as well as the results of past experiments suggest that spatial processing involves an ongoing and highly accurate comparison of spatial acoustic cues with self-motion cues. PMID:25228856
Kinematics of a Head-Neck Model Simulating Whiplash
ERIC Educational Resources Information Center
Colicchia, Giuseppe; Zollman, Dean; Wiesner, Hartmut; Sen, Ahmet Ilhan
2008-01-01
A whiplash event is a relative motion between the head and torso that occurs in rear-end automobile collisions. In particular, the large inertia of the head results in a horizontal translation relative to the thorax. This paper describes a simulation of the motion of the head and neck during a rear-end (whiplash) collision. A head-neck model that…
Nalbach, H O
1992-01-01
Pigeons freely standing in the centre of a two-dimensionally textured cylinder not only rotate but also laterally translate their head in response to the pattern sinusoidally oscillating or unidirectionally rotating around their vertical axis. The translational head movement dominates the response at high oscillation frequencies, whereas in a unidirectionally rotating drum head translation declines at about the same rate as the rotational response increases. It is suggested that this is a consequence of charging the 'velocity storage' in the vestibulo-ocular system. Similar to the rotational head movement (opto-collic reflex), the translational head movement is elicited via a wide-field motion sensitive system. The underlying mechanism can be described as vector integration of movement vectors tangential to the pattern rotation. Stimulation of the frontal visual field elicits largest translational responses while rotational responses can be elicited equally well from any azimuthal position of a moving pattern. Experiments where most of the pattern is occluded by a screen and the pigeon is allowed to view the stimulus through one or two windows demonstrate a short-range inhibition and long-range excitation between movement detectors that feed into the rotational system. Furthermore, the results obtained from such types of experiments suggest that the rotational system inhibits the translational system. These mechanisms may help the pigeon to decompose image flow into its translational and rotational components. Because of their translational response to a rotational stimulus, it is concluded, however, that pigeons either generally cannot perfectly perform the task or they need further visual information, like differential image motion, that was not available to them in the paradigms.
Gilbert, Jeremy L; Mehta, Manav; Pinder, Bryan
2009-01-01
Modular tapers continue to be used in a wide variety of orthopedic implants. In this study, stainless steel (ASTM F-1568) femoral hip stems combined with Co-Cr-Mo alloy heads (SS/CoCr) were tested in an in vitro fretting corrosion test set-up to assess the propensity for mechanically assisted corrosion. Three different aspects of the modular design were evaluated in this study: (1) material combination compared to CoCr/CoCr, (2) wet versus dry assembly for SS/CoCr couples, and (3) 0- and 6-mm head offset for SS/CoCr couples. Fretting corrosion tests over a range of cyclic loads up to 3300 N were performed, and continuous cyclic loading at 3300 N for 1 M cycles were performed on each group (n = 5). Fretting micromotion was measured as a function of cyclic load on select couples to detect the nature and extent of motion present. The results showed that SS/CoCr couples were more susceptible to fretting corrosion than CoCr/CoCr couples, that dry assembly does not prevent fretting corrosion from taking place but raises the onset load, and that 6-mm offset heads had higher visual evidence of fretting damage but showed mixed statistical results in terms of onset loads and OCP shifts and currents compared to the 0-mm offset samples. Current and voltage excursions over 1 million cycles tended to diminish towards their unloaded control levels but did not fully recover until cyclic loading ceased. Micromotion measurements indicated fretting motions in the range of 10-25 microm where 0-mm heads tended to piston on the trunion, while 6 mm heads tended to rock. (c) 2008 Wiley Periodicals, Inc.
Finite element analysis of moment-rotation relationships for human cervical spine.
Zhang, Qing Hang; Teo, Ee Chon; Ng, Hong Wan; Lee, Vee Sin
2006-01-01
A comprehensive, geometrically accurate, nonlinear C0-C7 FE model of head and cervical spine based on the actual geometry of a human cadaver specimen was developed. The motions of each cervical vertebral level under pure moment loading of 1.0 Nm applied incrementally on the skull to simulate the movements of the head and cervical spine under flexion, tension, axial rotation and lateral bending with the inferior surface of the C7 vertebral body fully constrained were analysed. The predicted range of motion (ROM) for each motion segment were computed and compared with published experimental data. The model predicted the nonlinear moment-rotation relationship of human cervical spine. Under the same loading magnitude, the model predicted the largest rotation in extension, followed by flexion and axial rotation, and least ROM in lateral bending. The upper cervical spines are more flexible than the lower cervical levels. The motions of the two uppermost motion segments account for half (or even higher) of the whole cervical spine motion under rotational loadings. The differences in the ROMs among the lower cervical spines (C3-C7) were relatively small. The FE predicted segmental motions effectively reflect the behavior of human cervical spine and were in agreement with the experimental data. The C0-C7 FE model offers potentials for biomedical and injury studies.
Panichi, Roberto; Botti, Fabio Massimo; Ferraresi, Aldo; Faralli, Mario; Kyriakareli, Artemis; Schieppati, Marco; Pettorossi, Vito Enrico
2011-04-01
Self-motion perception and vestibulo-ocular reflex (VOR) were studied during whole body yaw rotation in the dark at different static head positions. Rotations consisted of four cycles of symmetric sinusoidal and asymmetric oscillations. Self-motion perception was evaluated by measuring the ability of subjects to manually track a static remembered target. VOR was recorded separately and the slow phase eye position (SPEP) was computed. Three different head static yaw deviations (active and passive) relative to the trunk (0°, 45° to right and 45° to left) were examined. Active head deviations had a significant effect during asymmetric oscillation: the movement perception was enhanced when the head was kept turned toward the side of body rotation and decreased in the opposite direction. Conversely, passive head deviations had no effect on movement perception. Further, vibration (100 Hz) of the neck muscles splenius capitis and sternocleidomastoideus remarkably influenced perceived rotation during asymmetric oscillation. On the other hand, SPEP of VOR was modulated by active head deviation, but was not influenced by neck muscle vibration. Through its effects on motion perception and reflex gain, head position improved gaze stability and enhanced self-motion perception in the direction of the head deviation. Copyright © 2010 Elsevier B.V. All rights reserved.
A neural model of motion processing and visual navigation by cortical area MST.
Grossberg, S; Mingolla, E; Pack, C
1999-12-01
Cells in the dorsal medial superior temporal cortex (MSTd) process optic flow generated by self-motion during visually guided navigation. A neural model shows how interactions between well-known neural mechanisms (log polar cortical magnification, Gaussian motion-sensitive receptive fields, spatial pooling of motion-sensitive signals and subtractive extraretinal eye movement signals) lead to emergent properties that quantitatively simulate neurophysiological data about MSTd cell properties and psychophysical data about human navigation. Model cells match MSTd neuron responses to optic flow stimuli placed in different parts of the visual field, including position invariance, tuning curves, preferred spiral directions, direction reversals, average response curves and preferred locations for stimulus motion centers. The model shows how the preferred motion direction of the most active MSTd cells can explain human judgments of self-motion direction (heading), without using complex heading templates. The model explains when extraretinal eye movement signals are needed for accurate heading perception, and when retinal input is sufficient, and how heading judgments depend on scene layouts and rotation rates.
Space flight and neurovestibular adaptation
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Bloomberg, J. J.; Harm, D. L.; Paloski, W. H.
1994-01-01
Space flight represents a form of sensory stimulus rearrangement requiring modification of established terrestrial response patterns through central reinterpretation. Evidence of sensory reinterpretation is manifested as postflight modifications of eye/head coordination, locomotor patterns, postural control strategies, and illusory perceptions of self or surround motion in conjunction with head movements. Under normal preflight conditions, the head is stabilized during locomotion, but immediately postflight reduced head stability, coupled with inappropriate eye/head coordination, results in modifications of gait. Postflight postural control exhibits increased dependence on vision which compensates for inappropriate interpretation of otolith and proprioceptive inputs. Eye movements compensatory for perceived self motion, rather than actual head movements have been observed postflight. Overall, the in-flight adaptive modification of head stabilization strategies, changes in head/eye coordination, illusionary motion, and postural control are maladaptive for a return to the terrestrial environment.
Conservative treatment of sickle cell avascular necrosis of the femoral head.
Washington, E R; Root, L
1985-01-01
Treatment of avascular necrosis of the femoral head in adolescents with sickle cell anemia has not yet been standardized. In this study we review the literature and report on three patients with the Legg-Perthes-type avascular necrosis associated with sickle cell disease. These patients were successfully treated by partial weight-bearing with crutches and active range-of-motion exercises. We have examined physiologic and anatomic factors in this specific disease syndrome, which suggest that this may be the preferred method of treatment.
Rudolfsson, Thomas; Björklund, Martin; Svedmark, Åsa; Srinivasan, Divya; Djupsjöbacka, Mats
2017-01-01
Cervical range of motion (ROM) is commonly assessed in clinical practice and research. In a previous study we decomposed active cervical sagittal ROM into contributions from lower and upper levels of the cervical spine and found level- and direction-specific impairments in women with chronic non-specific neck pain. The present study aimed to validate these results and investigate if the specific impairments can be explained by the neutral posture (defining zero flexion/extension) or a movement strategy to avoid large gravitationally induced torques on the cervical spine. Kinematics of the head and thorax was assessed in sitting during maximal sagittal cervical flexion/extension (high torque condition) and maximal protraction (low torque condition) in 120 women with chronic non-specific neck pain and 40 controls. We derived the lower and upper cervical angles, and the head centre of mass (HCM), from a 3-segment kinematic model. Neutral head posture was assessed using a standardized procedure. Previous findings of level- and direction-specific impairments in neck pain were confirmed. Neutral head posture was equal between groups and did not explain the direction-specific impairments. The relative magnitude of group difference in HCM migration did not differ between high and low torques conditions, lending no support for our hypothesis that impairments in sagittal ROM are due to torque avoidance behaviour. The direction- and level-specific impairments in cervical sagittal ROM can be generalised to the population of women with non-specific neck pain. Further research is necessary to clarify if torque avoidance behaviour can explain the impairments.
Qian, Shinan
2011-01-01
Nmore » anoradian Surface Profilers (SPs) are required for state-of-the-art synchrotron radiation optics and high-precision optical measurements. ano-radian accuracy must be maintained in the large-angle test range. However, the beams' notable lateral motions during tests of most operating profilers, combined with the insufficiencies of their optical components, generate significant errors of ∼ 1 μ rad rms in the measurements. The solution to nano-radian accuracy for the new generation of surface profilers in this range is to apply a scanning optical head, combined with nontilted reference beam. I describe here my comparison of different scan modes and discuss some test results.« less
An empirical investigation of motion effects in eMRI of interictal epileptiform spikes.
Sundaram, Padmavathi; Mulkern, Robert V; Wells, William M; Triantafyllou, Christina; Loddenkemper, Tobias; Bubrick, Ellen J; Orbach, Darren B
2011-12-01
We recently developed a functional neuroimaging technique called encephalographic magnetic resonance imaging (eMRI). Our method acquires rapid single-shot gradient-echo echo-planar MRI (repetition time=47 ms); it attempts to measure an MR signal more directly linked to neuronal electromagnetic activity than existing methods. To increase the likelihood of detecting such an MR signal, we recorded concurrent MRI and scalp electroencephalography (EEG) during fast (20-200 ms), localized, high-amplitude (>50 μV on EEG) cortical discharges in a cohort of focal epilepsy patients. Seen on EEG as interictal spikes, these discharges occur in between seizures and induced easily detectable MR magnitude and phase changes concurrent with the spikes with a lag of milliseconds to tens of milliseconds. Due to the time scale of the responses, localized changes in blood flow or hemoglobin oxygenation are unlikely to cause the MR signal changes that we observed. While the precise underlying mechanisms are unclear, in this study, we empirically investigate one potentially important confounding variable - motion. Head motion in the scanner affects both EEG and MR recording. It can produce brief "spike-like" artifacts on EEG and induce large MR signal changes similar to our interictal spike-related signal changes. In order to explore the possibility that interictal spikes were associated with head motions (although such an association had never been reported), we had previously tracked head position in epilepsy patients during interictal spikes and explicitly demonstrated a lack of associated head motion. However, that study was performed outside the MR scanner, and the root-mean-square error in the head position measurement was 0.7 mm. The large inaccuracy in this measurement therefore did not definitively rule out motion as a possible signal generator. In this study, we instructed healthy subjects to make deliberate brief (<500 ms) head motions inside the MR scanner and imaged these head motions with concurrent EEG and MRI. We compared these artifactual MR and EEG data to genuine interictal spikes. While per-voxel MR and per-electrode EEG time courses for the motion case can mimic the corresponding time courses associated with a genuine interictal spike, head motion can be unambiguously differentiated from interictal spikes via scalp EEG potential maps. Motion induces widespread changes in scalp potential, whereas interictal spikes are localized and have a regional fall-off in amplitude. These findings make bulk head motion an unlikely generator of the large spike-related MR signal changes that we had observed. Further work is required to precisely identify the underlying mechanisms. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wiersma, Rodney D.; Wen, Zhifei; Sadinski, Meredith; Farrey, Karl; Yenice, Kamil M.
2010-01-01
Stereotactic radiosurgery delivers radiation with great spatial accuracy. To achieve sub-millimeter accuracy for intracranial SRS, a head ring is rigidly fixated to the skull to create a fixed reference. For some patients, the invasiveness of the ring can be highly uncomfortable and not well tolerated. In addition, placing and removing the ring requires special expertise from a neurosurgeon, and patient setup time for SRS can often be long. To reduce the invasiveness, hardware limitations and setup time, we are developing a system for performing accurate head positioning without the use of a head ring. The proposed method uses real-time 6D optical position feedback for turning on and off the treatment beam (gating) and guiding a motor-controlled 3D head motion compensation stage. The setup consists of a central control computer, an optical patient motion tracking system and a 3D motion compensation stage attached to the front of the LINAC couch. A styrofoam head cast was custom-built for patient support and was mounted on the compensation stage. The motion feedback of the markers was processed by the control computer, and the resulting motion of the target was calculated using a rigid body model. If the target deviated beyond a preset position of 0.2 mm, an automatic position correction was performed with stepper motors to adjust the head position via the couch mount motion platform. In the event the target deviated more than 1 mm, a safety relay switch was activated and the treatment beam was turned off. The feasibility of the concept was tested using five healthy volunteers. Head motion data were acquired with and without the use of motion compensation over treatment times of 15 min. On average, test subjects exceeded the 0.5 mm tolerance 86% of the time and the 1.0 mm tolerance 45% of the time without motion correction. With correction, this percentage was reduced to 5% and 2% for the 0.5 mm and 1.0 mm tolerances, respectively.
Three-dimensional motion of the uncovertebral joint during head rotation.
Nagamoto, Yukitaka; Ishii, Takahiro; Iwasaki, Motoki; Sakaura, Hironobu; Moritomo, Hisao; Fujimori, Takahito; Kashii, Masafumi; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2012-10-01
The uncovertebral joints are peculiar but clinically important anatomical structures of the cervical vertebrae. In the aged or degenerative cervical spine, osteophytes arising from an uncovertebral joint can cause cervical radiculopathy, often necessitating decompression surgery. Although these joints are believed to bear some relationship to head rotation, how the uncovertebral joints work during head rotation remains unclear. The purpose of this study is to elucidate 3D motion of the uncovertebral joints during head rotation. Study participants were 10 healthy volunteers who underwent 3D MRI of the cervical spine in 11 positions during head rotation: neutral (0°) and 15° increments to maximal head rotation on each side (left and right). Relative motions of the cervical spine were calculated by automatically superimposing a segmented 3D MR image of the vertebra in the neutral position over images of each position using the volume registration method. The 3D intervertebral motions of all 10 volunteers were standardized, and the 3D motion of uncovertebral joints was visualized on animations using data for the standardized motion. Inferred contact areas of uncovertebral joints were also calculated using a proximity mapping technique. The 3D animation of uncovertebral joints during head rotation showed that the joints alternate between contact and separation. Inferred contact areas of uncovertebral joints were situated directly lateral at the middle cervical spine and dorsolateral at the lower cervical spine. With increasing angle of rotation, inferred contact areas increased in the middle cervical spine, whereas areas in the lower cervical spine slightly decreased. In this study, the 3D motions of uncovertebral joints during head rotation were depicted precisely for the first time.
Haller, Sven; Monsch, Andreas U; Richiardi, Jonas; Barkhof, Frederik; Kressig, Reto W; Radue, Ernst W
2014-11-01
Motion artifacts are a well-known and frequent limitation during neuroimaging workup of cognitive decline. While head motion typically deteriorates image quality, we test the hypothesis that head motion differs systematically between healthy controls (HC), amnestic mild cognitive impairment (aMCI) and Alzheimer disease (AD) and consequently might contain diagnostic information. This prospective study was approved by the local ethics committee and includes 28 HC (age 71.0 ± 6.9 years, 18 females), 15 aMCI (age 67.7 ± 10.9 years, 9 females) and 20 AD (age 73.4 ± 6.8 years, 10 females). Functional magnetic resonance imaging (fMRI) at 3T included a 9 min echo-planar imaging sequence with 180 repetitions. Cumulative average head rotation and translation was estimated based on standard fMRI preprocessing and compared between groups using receiver operating characteristic statistics. Global cumulative head rotation discriminated aMCI from controls [p < 0.01, area under curve (AUC) 0.74] and AD from controls (p < 0.01, AUC 0.73). The ratio of rotation z versus y discriminated AD from controls (p < 0.05, AUC 0.71) and AD from aMCI (p < 0.05, AUC of 0.75). Head motion systematically differs between aMCI/AD and controls. Since motion is not random but convoluted with diagnosis, the higher amount of motion in aMCI and AD as compared to controls might be a potential confounding factor for fMRI group comparisons. Additionally, head motion not only deteriorates image quality, yet also contains useful discriminatory information and is available for free as a "side product" of fMRI data preprocessing.
Dunleavy, Kim; Neil, Joseph; Tallon, Allison; Adamo, Diane E
2015-09-01
The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures. (1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared. (1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and -1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05). Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test-retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles.
Neil, Joseph; Tallon, Allison; Adamo, Diane E.
2015-01-01
Objectives The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures. Methods (1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared. Results (1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and −1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05). Discussion Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test–retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles. PMID:26917936
2004-06-30
virtual space, as well as to match specific attributes of natural locomotion, such as perceived velocity and caloric expenditure . Moreover, the...wide range of postural motions (e.g., crouching, jumping , and bending to look around objects) with gestural stepping motions. The attributes of in...approximately 8 ¥ 8 ¥ 8 ft. The harness itself was an initial design made out of PVC pipe at the waist and above the head, with rope connecting the
NASA Technical Reports Server (NTRS)
Han, Yanning H.; Kumar, Arun N.; Reschke, Millard F.; Somers, Jeffrey T.; Dell'Osso, Louis F.; Leigh, R. John
2004-01-01
We studied horizontal eye movements induced by en-bloc yaw rotation, over a frequency range 0.2 - 2.8 Hz, in 10 normal human subjects as th ey monocularly viewed a target located at their near point of focus. We measured gain and phase relationships between eye-in-head velocity and head velocity when the near target was either earth-fixed or head-fixed. During viewing of the earth-fixed near target,median gain was 1.49 (range 1.24 - 1.87) at 0.2 Hz for the group of subjects, but decl ined at higher frequencies, so that at 2.8 Hz median gain was 1.08 (r ange 0.68 - 1.67). During viewing of the head-fixed near target, median gain was 0.03 (range 0.01 - 0.10) at 0.2 Hz for the group of subjec ts, but increased at higher frequencies, so that at 2.8 Hz median gai n was 0.71 (range 0.28 - 0.94). We estimated the vestibular contribution to these responses (vestibulo-ocular reflex gain, Gvor) by applyin g transient head perturbations (peak acceleration> 1,000 deg's(exp 2) ) during sinusoidal rotation under the two viewing conditions. Median Gvor, estimated < 70m after the onset of head perturbation, was 0.98 (range 0.39 - 1.42) while viewing the earth-fixed near target, and 0. 97 (range 0.37 - 1.33) while viewing the head-fixed near target. For the group of subjects, 9 out of 10 subjects showed no sigificant diff erence of Gvor between the two viewing conditions ( p > 0.053 ) at all test frequencies. Since Gvor accounted for only approximately 73% of the overall response gain during viewing of the earth-fixed target, we investigated the relative contributions of non-vestibular factors. When subjects viewed the earth-fixed target under strobe illumination , to eliminate retinal image slip information, the gain of compensato ry eye movements declined compared with viewing in ambient room light . During sum-of-sine head rotations, while viewing the earth-fixed target, to minimize contributions from predictive mechanisms, gain also declined Nonetheless, simple superposition of smooth-pursuit tracking of sinusoidal target motion could not fully account for the overall r esponse at higher frequencies, suggesting other non-vestibular contributions. During binocular viewing conditions when vergence angle was s ignificantly greater than monocular viewing (p < 0.001), this gain of compensatory eye movements did not show proportional change; indeed, gain could not be correlated with vergence angle during monocular or binocular viewing. We conclude that several separate factors contribute to generate eye rotations during sinusoidal yaw head rotations whi le viewing a near target; these include the VOR, visual-tracking eye movements that utilize retinal image motion, predictive eye movements and, possibly, other unidentified nonvestibular factors. For these experiments, vergence was not an important determinant of response gain .
Tempest, Gavin D; Eston, Roger G; Parfitt, Gaynor
2017-11-01
The aim of this observational study was to compare head motion and prefrontal haemodynamics during exercise using three commercial cycling ergometers. Participants (n = 12) completed an incremental exercise test to exhaustion during upright, recumbent and semi-recumbent cycling. Head motion (using accelerometry), physiological data (oxygen uptake, end-tidal carbon dioxide [P ET CO 2 ] and heart rate) and changes in prefrontal haemodynamics (oxygenation, deoxygenation and blood volume using near infrared spectroscopy [NIRS]) were recorded. Despite no difference in oxygen uptake and heart rate, head motion was higher and P ET CO 2 was lower during upright cycling at maximal exercise (P<0·05). Analyses of covariance (covariates: head motion P>0·05; P ET CO 2 , P<0·01) revealed that prefrontal oxygenation was higher during semi-recumbent than recumbent cycling and deoxygenation and blood volume were higher during upright than recumbent and semi-recumbent cycling (respectively; P<0·05). This work highlights the robustness of the utility of NIRS to head motion and describes the potential postural effects upon the prefrontal haemodynamic response during upright and recumbent cycling exercise. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Inertial vestibular coding of motion: concepts and evidence
NASA Technical Reports Server (NTRS)
Hess, B. J.; Angelaki, D. E.
1997-01-01
Central processing of inertial sensory information about head attitude and motion in space is crucial for motor control. Vestibular signals are coded relative to a non-inertial system, the head, that is virtually continuously in motion. Evidence for transformation of vestibular signals from head-fixed sensory coordinates to gravity-centered coordinates have been provided by studies of the vestibulo-ocular reflex. The underlying central processing depends on otolith afferent information that needs to be resolved in terms of head translation related inertial forces and head attitude dependent pull of gravity. Theoretical solutions have been suggested, but experimental evidence is still scarce. It appears, along these lines, that gaze control systems are intimately linked to motor control of head attitude and posture.
Space flight and changes in spatial orientation
NASA Technical Reports Server (NTRS)
Reschke, Millard F.; Bloomberg, Jacob J.; Harm, Deborah L.; Paloski, William H.
1992-01-01
From a sensory point of view, space flight represents a form of stimulus rearrangement requiring modification of established terrestrial response patterns through central reinterpretation. Evidence of sensory reinterpretation is manifested as postflight modifications of eye/head coordination, locomotor patterns, postural control strategies, and illusory perceptions of self or surround motion in conjunction with head movements. Under normal preflight conditions, the head is stabilized during locomotion, but immediately postflight reduced head stability, coupled with inappropriate eye/head coordination, results in modifications of gait. Postflight postural control exhibits increased dependence on vision which compensates for inappropriate interpretation of otolith and proprioceptive inputs. Eye movements compensatory for perceived self motion, rather than actual head movements have been observed postflight. Overall, the in-flight adaptive modification of head stabilization strategies, changes in head/eye coordination, illusionary motion, and postural control are maladaptive for a return to the terrestrial environment. Appropriate countermeasures for long-duration flights will rely on preflight adaptation and in-flight training.
Effect of direction of head movement on motion sickness caused by Coriolis stimulation.
Woodman, P D; Griffin, M J
1997-02-01
During constant speed rotation of the body, head rotation about an axis other than the axis of rotation of the body (i.e., Coriolis is stimulation) induces motion sickness. The position of the body relative to the center of rotation will influence the sickness caused by Coriolis stimulation; the direction of head movement will not affect the sickness caused by Coriolis stimulation. There were 24 seated subjects (12 male, 12 female) who made 30 degrees pitch motions of the head every 30 s while rotating about a vertical axis at 10 r.p.m. on a turntable at two separate locations: a) at the center of rotation; and b) 0.75 m from the center of rotation. After each head movement the subjects gave ratings of motion illness. There was no significant difference between illness 0.75 m from the center of rotation and illness at the center of rotation, or between the illness ratings from male and female subjects. Moving the head up from the horizontal caused significantly fewer increases in ratings of motion illness than moving the head back down to the horizontal. Precise location of the body at the center of rotation is not critical during Coriolis stimulation, but the direction of head movement has a large effect on nausea. An influence of somatosensory information on sickness caused by Coriolis stimulation is suggested.
Savalia, Neil K.; Agres, Phillip F.; Chan, Micaela Y.; Feczko, Eric J.; Kennedy, Kristen M.
2016-01-01
Abstract Motion‐contaminated T1‐weighted (T1w) magnetic resonance imaging (MRI) results in misestimates of brain structure. Because conventional T1w scans are not collected with direct measures of head motion, a practical alternative is needed to identify potential motion‐induced bias in measures of brain anatomy. Head movements during functional MRI (fMRI) scanning of 266 healthy adults (20–89 years) were analyzed to reveal stable features of in‐scanner head motion. The magnitude of head motion increased with age and exhibited within‐participant stability across different fMRI scans. fMRI head motion was then related to measurements of both quality control (QC) and brain anatomy derived from a T1w structural image from the same scan session. A procedure was adopted to “flag” individuals exhibiting excessive head movement during fMRI or poor T1w quality rating. The flagging procedure reliably reduced the influence of head motion on estimates of gray matter thickness across the cortical surface. Moreover, T1w images from flagged participants exhibited reduced estimates of gray matter thickness and volume in comparison to age‐ and gender‐matched samples, resulting in inflated effect sizes in the relationships between regional anatomical measures and age. Gray matter thickness differences were noted in numerous regions previously reported to undergo prominent atrophy with age. Recommendations are provided for mitigating this potential confound, and highlight how the procedure may lead to more accurate measurement and comparison of anatomical features. Hum Brain Mapp 38:472–492, 2017. © 2016 Wiley Periodicals, Inc. PMID:27634551
Visualization of 3D elbow kinematics using reconstructed bony surfaces
NASA Astrophysics Data System (ADS)
Lalone, Emily A.; McDonald, Colin P.; Ferreira, Louis M.; Peters, Terry M.; King, Graham J. W.; Johnson, James A.
2010-02-01
An approach for direct visualization of continuous three-dimensional elbow kinematics using reconstructed surfaces has been developed. Simulation of valgus motion was achieved in five cadaveric specimens using an upper arm simulator. Direct visualization of the motion of the ulna and humerus at the ulnohumeral joint was obtained using a contact based registration technique. Employing fiducial markers, the rendered humerus and ulna were positioned according to the simulated motion. The specific aim of this study was to investigate the effect of radial head arthroplasty on restoring elbow joint stability after radial head excision. The position of the ulna and humerus was visualized for the intact elbow and following radial head excision and replacement. Visualization of the registered humerus/ulna indicated an increase in valgus angulation of the ulna with respect to the humerus after radial head excision. This increase in valgus angulation was restored to that of an elbow with a native radial head following radial head arthroplasty. These findings were consistent with previous studies investigating elbow joint stability following radial head excision and arthroplasty. The current technique was able to visualize a change in ulnar position in a single DoF. Using this approach, the coupled motion of ulna undergoing motion in all 6 degrees-of-freedom can also be visualized.
Siegler, Sorin; Caravaggi, Paolo; Tangorra, James; Milone, Mary; Namani, Ramya; Marchetto, Paul A
2015-10-15
The posture of the head and neck is critical for predicting and assessing the risk of injury during high accelerations, such as those arising during motor accidents or in collision sports. Current knowledge suggests that the head's range-of-motion (ROM) and the torque-generating capability of neck muscles are both dependent and affected by head posture. A deeper understanding of the relationship between head posture, ROM and maximum torque-generating capability of neck muscles may help assess the risk of injury and develop means to reduce such risks. The aim of this study was to use a previously-validated device, known as Neck Flexibility Tester, to quantify the effects of head's posture on the available ROM and torque-generating capability of neck muscles. Ten young asymptomatic volunteers were enrolled in the study. The tri-axial orientation of the subjects' head was controlled via the Neck Flexibility Tester device. The head ROM was measured for each flexed, extended, axially rotated, and laterally bent head's orientation and compared to that in unconstrained neutral posture. Similarly, the torque applied about the three anatomical axes during Isometric Maximum Voluntary Contraction (IMVC) of the neck muscles was measured in six head's postures and compared to that in fully-constrained neutral posture. The further from neutral the neck posture was the larger the decrease in ROM and IMVC. Head extension and combined two-plane rotations postures, such as extension with lateral bending, produced the largest decreases in ROM and IMVC, thus suggesting that these postures pose the highest potential risk for injury. Copyright © 2015 Elsevier Ltd. All rights reserved.
Grip, Helena; Sundelin, Gunnevi; Gerdle, Björn; Karlsson, J Stefan
2007-10-01
The ability to reproduce head position can be affected in patients after a neck injury. The repositioning error is commonly used as a measure of proprioception, but variations in the movement might provide additional information. The axis of motion and target performance were analyzed during a head repositioning task (flexion, extension and side rotations) for 24 control subjects, 22 subjects with whiplash-associated disorders and 21 with non-specific neck pain. Questionnaires regarding pain intensity and fear avoidance were collected. Head position and axis of motion parameters were calculated using a helical axis model with a moving window of 4 degrees . During flexion the whiplash group had a larger constant repositioning error than the control group (-1.8(2.9) degrees vs. 0.1(2.4) degrees , P=0.04). The axis was more inferior in both neck pain groups (12.0(1.6)cm vs. 14.5(2.0)cm, P<0.05) indicating movement at a lower level in the spine. Including pain intensity from shoulder and neck region as covariates showed an effect on the axis position (P=0.03 and 0.04). During axial rotation to the left there was more variation in axis direction for neckpain groups as compared with controls (4.0(1.7) degrees and 3.7(2.4) degrees vs. 2.3(1.9) degrees , P=0.01 and 0.05). No significant difference in fear avoidance was found between the two neck pain groups. Measuring variation in the axis of motion together with target performance gives objective measures on proprioceptive ability that are difficult to quantify by visual inspection. Repositioning errors were in general small, suggesting it is not sufficient as a single measurement variable in a clinical situation, but should be measured in combination with other tests, such as range of motion.
Motion sickness, console video games, and head-mounted displays.
Merhi, Omar; Faugloire, Elise; Flanagan, Moira; Stoffregen, Thomas A
2007-10-01
We evaluated the nauseogenic properties of commercial console video games (i.e., games that are sold to the public) when presented through a head-mounted display. Anecdotal reports suggest that motion sickness may occur among players of contemporary commercial console video games. Participants played standard console video games using an Xbox game system. We varied the participants' posture (standing vs. sitting) and the game (two Xbox games). Participants played for up to 50 min and were asked to discontinue if they experienced any symptoms of motion sickness. Sickness occurred in all conditions, but it was more common during standing. During seated play there were significant differences in head motion between sick and well participants before the onset of motion sickness. The results indicate that commercial console video game systems can induce motion sickness when presented via a head-mounted display and support the hypothesis that motion sickness is preceded by instability in the control of seated posture. Potential applications of this research include changes in the design of console video games and recommendations for how such systems should be used.
Surgical hip dislocation for treatment of cam femoroacetabular impingement.
Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, K N; KoKo, Aung; Zaw, Than; Siddhartha, A
2015-01-01
Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°-108°) to 46.35° (range 39°-58°). Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.
Head motion during MRI acquisition reduces gray matter volume and thickness estimates.
Reuter, Martin; Tisdall, M Dylan; Qureshi, Abid; Buckner, Randy L; van der Kouwe, André J W; Fischl, Bruce
2015-02-15
Imaging biomarkers derived from magnetic resonance imaging (MRI) data are used to quantify normal development, disease, and the effects of disease-modifying therapies. However, motion during image acquisition introduces image artifacts that, in turn, affect derived markers. A systematic effect can be problematic since factors of interest like age, disease, and treatment are often correlated with both a structural change and the amount of head motion in the scanner, confounding the ability to distinguish biology from artifact. Here we evaluate the effect of head motion during image acquisition on morphometric estimates of structures in the human brain using several popular image analysis software packages (FreeSurfer 5.3, VBM8 SPM, and FSL Siena 5.0.7). Within-session repeated T1-weighted MRIs were collected on 12 healthy volunteers while performing different motion tasks, including two still scans. We show that volume and thickness estimates of the cortical gray matter are biased by head motion with an average apparent volume loss of roughly 0.7%/mm/min of subject motion. Effects vary across regions and remain significant after excluding scans that fail a rigorous quality check. In view of these results, the interpretation of reported morphometric effects of movement disorders or other conditions with increased motion tendency may need to be revisited: effects may be overestimated when not controlling for head motion. Furthermore, drug studies with hypnotic, sedative, tranquilizing, or neuromuscular-blocking substances may contain spurious "effects" of reduced atrophy or brain growth simply because they affect motion distinct from true effects of the disease or therapeutic process. Copyright © 2014 Elsevier Inc. All rights reserved.
Motion Sickness Treatment Apparatus and Method
NASA Technical Reports Server (NTRS)
Reschke, Millard F. (Inventor); Somers, Jeffrey T. (Inventor); Ford, George A. (Inventor)
2005-01-01
Methods and apparatus are disclosed for treating motion sickness. In a preferred embodiment a method of the invention comprises operating eyewear having shutter lenses to open said shutter lenses at a selected operating frequency ranging from within about 3 Hz to about 50 Hz. The shutter lenses are opened for a short duration at the selected operating frequency wherein the duration is selected to prevent retinal slip. The shutter lenses may be operated at a relatively slow frequency of about 4 Hz when the user is in passive activity such as riding in a boat or car or in limited motion situations in a spacecraft. The shutter lenses may be operated at faster frequencies related to motion of the user's head when the user is active.
Motion sickness and postural sway in console video games.
Stoffregen, Thomas A; Faugloire, Elise; Yoshida, Ken; Flanagan, Moira B; Merhi, Omar
2008-04-01
We tested the hypotheses that (a) participants might develop motion sickness while playing "off-the-shelf" console video games and (b) postural motion would differ between sick and well participants, prior to the onset of motion sickness. There have been many anecdotal reports of motion sickness among people who play console video games (e.g., Xbox, PlayStation). Participants (40 undergraduate students) played a game continuously for up to 50 min while standing or sitting. We varied the distance to the display screen (and, consequently, the visual angle of the display). Across conditions, the incidence of motion sickness ranged from 42% to 56%; incidence did not differ across conditions. During game play, head and torso motion differed between sick and well participants prior to the onset of subjective symptoms of motion sickness. The results indicate that console video games carry a significant risk of motion sickness. Potential applications of this research include changes in the design of console video games and recommendations for how such systems should be used.
Head movements encode emotions during speech and song.
Livingstone, Steven R; Palmer, Caroline
2016-04-01
When speaking or singing, vocalists often move their heads in an expressive fashion, yet the influence of emotion on vocalists' head motion is unknown. Using a comparative speech/song task, we examined whether vocalists' intended emotions influence head movements and whether those movements influence the perceived emotion. In Experiment 1, vocalists were recorded with motion capture while speaking and singing each statement with different emotional intentions (very happy, happy, neutral, sad, very sad). Functional data analyses showed that head movements differed in translational and rotational displacement across emotional intentions, yet were similar across speech and song, transcending differences in F0 (varied freely in speech, fixed in song) and lexical variability. Head motion specific to emotional state occurred before and after vocalizations, as well as during sound production, confirming that some aspects of movement were not simply a by-product of sound production. In Experiment 2, observers accurately identified vocalists' intended emotion on the basis of silent, face-occluded videos of head movements during speech and song. These results provide the first evidence that head movements encode a vocalist's emotional intent and that observers decode emotional information from these movements. We discuss implications for models of head motion during vocalizations and applied outcomes in social robotics and automated emotion recognition. (c) 2016 APA, all rights reserved).
Man-in-the-loop study of filtering in airborne head tracking tasks
NASA Technical Reports Server (NTRS)
Lifshitz, S.; Merhav, S. J.
1992-01-01
A human-factors study is conducted of problems due to vibrations during the use of a helmet-mounted display (HMD) in tracking tasks whose major factors are target motion and head vibration. A method is proposed for improving aiming accuracy in such tracking tasks on the basis of (1) head-motion measurement and (2) the shifting of the reticle in the HMD in ways that inhibit much of the involuntary apparent motion of the reticle, relative to the target, and the nonvoluntary motion of the teleoperated device. The HMD inherently furnishes the visual feedback required by this scheme.
Outcomes of coronoid-first repair in terrible triad injuries of the elbow.
Zhang, Junren; Tan, Mark; Kwek, Ernest Beng Kee
2017-09-01
Clinical outcomes of terrible triad injuries (TTIs) of the elbow are historically poor. To date, it is still debatable whether the coronoid needs to be fixed and if so, how and in which sequence. Between 2010 and 2013, 13 patients were treated surgically for acute TTIs of the elbow at a Tertiary Level 1 Trauma Centre by a single surgeon, using a standardized protocol, which included coronoid-brachialis complex fixation via pull-through trans-osseous sutures, radial head fixation or prosthetic replacement and a repair of the lateral ulnar collateral ligament. Repair of the medial collateral ligament (MCL) was done if valgus-stress test demonstrated persistent instability. Patients were then followed-up with clinical and radiological evaluation by the senior author until fracture union and elbow range of motion reached a plateau. Outcomes measured were range of motion, DASH scores and MEPS, as well as surgical complications. Intraoperative stability was achieved in all 13 cases, MCL repair was required in 3 cases and application of external fixation was not required in any case. Patients were followed-up for an average length of 27.7 months and the minimum follow-up period was 12 months. The average age of patients was 46.4 years (range 35-79 years old) at the time of trauma. This included eight Regan-Morrey Type I and five Regan-Morrey Type II coronoid fractures, with ten Mason Type I/II and three Mason Type III radial head fractures. The average arc of ulno-humeral motion was 105.0° (range 80°-135°). The average flexion contracture was 15.0° (range 0°-40°). The average supination-pronation arc was 114.9° (range 0°-180°). The average MEPS was 85 of 100 (range 45-100) and the average DASH score was 21.2 of 100 (range 1.7-61.2). A single case of radio-ulnar synostosis, heterotropic ossification and two cases of recurrent elbow instability were noted. The coronoid-first surgical approach, using a suture-lasso fixation method, has technical benefits for us and showed good clinical success in our series. This is important with postero-medial rotatory instability being common in our series of TTIs. We emphasize not to miss a TTI in an apparently isolated low Mason class radial head fracture.
Extracting heading and temporal range from optic flow: Human performance issues
NASA Technical Reports Server (NTRS)
Kaiser, Mary K.; Perrone, John A.; Stone, Leland; Banks, Martin S.; Crowell, James A.
1993-01-01
Pilots are able to extract information about their vehicle motion and environmental structure from dynamic transformations in the out-the-window scene. In this presentation, we focus on the information in the optic flow which specifies vehicle heading and distance to objects in the environment, scaled to a temporal metric. In particular, we are concerned with modeling how the human operators extract the necessary information, and what factors impact their ability to utilize the critical information. In general, the psychophysical data suggest that the human visual system is fairly robust to degradations in the visual display, e.g., reduced contrast and resolution or restricted field of view. However, extraneous motion flow, i.e., introduced by sensor rotation, greatly compromises human performance. The implications of these models and data for enhanced/synthetic vision systems are discussed.
Björklund, Martin; Svedmark, Åsa; Srinivasan, Divya; Djupsjöbacka, Mats
2017-01-01
Background Cervical range of motion (ROM) is commonly assessed in clinical practice and research. In a previous study we decomposed active cervical sagittal ROM into contributions from lower and upper levels of the cervical spine and found level- and direction-specific impairments in women with chronic non-specific neck pain. The present study aimed to validate these results and investigate if the specific impairments can be explained by the neutral posture (defining zero flexion/extension) or a movement strategy to avoid large gravitationally induced torques on the cervical spine. Methods Kinematics of the head and thorax was assessed in sitting during maximal sagittal cervical flexion/extension (high torque condition) and maximal protraction (low torque condition) in 120 women with chronic non-specific neck pain and 40 controls. We derived the lower and upper cervical angles, and the head centre of mass (HCM), from a 3-segment kinematic model. Neutral head posture was assessed using a standardized procedure. Findings Previous findings of level- and direction-specific impairments in neck pain were confirmed. Neutral head posture was equal between groups and did not explain the direction-specific impairments. The relative magnitude of group difference in HCM migration did not differ between high and low torques conditions, lending no support for our hypothesis that impairments in sagittal ROM are due to torque avoidance behaviour. Interpretation The direction- and level-specific impairments in cervical sagittal ROM can be generalised to the population of women with non-specific neck pain. Further research is necessary to clarify if torque avoidance behaviour can explain the impairments. PMID:28099504
NASA Astrophysics Data System (ADS)
Liu, Mingyue; Xiao, Longfei; Yang, Jianmin; Tian, Xinliang
2017-05-01
The vortex-induced motions (VIMs) of semi-submersibles have emerged as an important issue in offshore engineering, as they pose a threat to safe and reliable operations and severely affect the fatigue lives of risers and mooring systems. The VIM response depends on the shape of the submerged structure and thus is significantly influenced by the design parameters related to the columns and pontoons. Numerical simulations by the detached Eddy simulation method are validated by experimental data and then used for parametric analysis of the VIM performance of various semi-submersibles with different column rounded ratios (Rc/L ) and pontoon rounded ratios (Rp/Lp ). The results show that the transverse amplitudes of a semi-submersible with circular columns at a 0° current heading are twice as large as those at a 45° current heading. However, the semi-submersible with rounded square columns shows more significant transverse motions at a 45° current heading than at a 0° current heading. Furthermore, at the 45° current heading, the transverse amplitudes of the semi-submersibles show a rapid increase as the column radius increases in the range of Rc/L <0.1 . The peak values remain roughly the same for 0.1 ≤Rc/L ≤0.2 and then decrease as the column radius increases (Rc/L ≥0.3 ). In addition, the effect of the pontoon shape on the transverse response is negligible for semi-submersibles with sharp square columns, while for semi-submersibles with rounded square columns or circular columns, the sharp rectangular pontoons greatly mitigate the VIM response.
Lateral idiopathic subluxation of the radial head. Case report.
Lancaster, S; Horowitz, M
1987-01-01
Idiopathic subluxation of the radial head (ISRH) is a rare entity that is separate from congenital dislocations of the radial head, both symptomatically and radiographically. ISRH causes pain and restriction of rotation. A dome-shaped radial head, a hypertrophied ulna, and a hypoplastic capitellum are not present in ISRH, as they are in a congenital dislocation of the radial head (CDRH). A true lateral ISRH is used as an example to demonstrate these differences. Remodeling of the radial head may preserve motion in the joint surface deformed by growth along abnormal planes of motion.
Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET.
Noonan, P J; Howard, J; Hallett, W A; Gunn, R N
2015-11-21
Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.
Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET
NASA Astrophysics Data System (ADS)
Noonan, P. J.; Howard, J.; Hallett, W. A.; Gunn, R. N.
2015-11-01
Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.
Position of the prosthesis and the incidence of dislocation following total hip replacement.
He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song
2007-07-05
Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.
Synchronization of multi-agent systems with metric-topological interactions.
Wang, Lin; Chen, Guanrong
2016-09-01
A hybrid multi-agent systems model integrating the advantages of both metric interaction and topological interaction rules, called the metric-topological model, is developed. This model describes planar motions of mobile agents, where each agent can interact with all the agents within a circle of a constant radius, and can furthermore interact with some distant agents to reach a pre-assigned number of neighbors, if needed. Some sufficient conditions imposed only on system parameters and agent initial states are presented, which ensure achieving synchronization of the whole group of agents. It reveals the intrinsic relationships among the interaction range, the speed, the initial heading, and the density of the group. Moreover, robustness against variations of interaction range, density, and speed are investigated by comparing the motion patterns and performances of the hybrid metric-topological interaction model with the conventional metric-only and topological-only interaction models. Practically in all cases, the hybrid metric-topological interaction model has the best performance in the sense of achieving highest frequency of synchronization, fastest convergent rate, and smallest heading difference.
Walker, Luke; Chinnaiyan, Prakash; Forster, Kenneth
2008-01-01
We conducted a comprehensive evaluation of the clinical accuracy of an image‐guided frameless intracranial radiosurgery system. All links in the process chain were tested. Using healthy volunteers, we evaluated a novel method to prospectively quantify the range of target motion for optimal determination of the planning target volume (PTV) margin. The overall system isocentric accuracy was tested using a rigid anthropomorphic phantom containing a hidden target. Intrafraction motion was simulated in 5 healthy volunteers. Reinforced head‐and‐shoulders thermoplastic masks were used for immobilization. The subjects were placed in a treatment position for 15 minutes (the maximum expected time between repeated isocenter localizations) and the six‐degrees‐of‐freedom target displacements were recorded with high frequency by tracking infrared markers. The markers were placed on a customized piece of thermoplastic secured to the head independently of the immobilization mask. Additional data were collected with the subjects holding their breath, talking, and deliberately moving. As compared with fiducial matching, the automatic registration algorithm did not introduce clinically significant errors (<0.3 mm difference). The hidden target test confirmed overall system isocentric accuracy of ≤1 mm (total three‐dimensional displacement). The subjects exhibited various patterns and ranges of head motion during the mock treatment. The total displacement vector encompassing 95% of the positional points varied from 0.4 mm to 2.9 mm. Pre‐planning motion simulation with optical tracking was tested on volunteers and appears promising for determination of patient‐specific PTV margins. Further patient study is necessary and is planned. In the meantime, system accuracy is sufficient for confident clinical use with 3 mm PTV margins. PACS number: 87.53.Ly
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ogunmolu, O; Gans, N; Jiang, S
Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance ofmore » the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.« less
Tracking and characterizing the head motion of unanaesthetized rats in positron emission tomography
Kyme, Andre; Meikle, Steven; Baldock, Clive; Fulton, Roger
2012-01-01
Positron emission tomography (PET) is an important in vivo molecular imaging technique for translational research. Imaging unanaesthetized rats using motion-compensated PET avoids the confounding impact of anaesthetic drugs and enables animals to be imaged during normal or evoked behaviour. However, there is little published data on the nature of rat head motion to inform the design of suitable marker-based motion-tracking set-ups for brain imaging—specifically, set-ups that afford close to uninterrupted tracking. We performed a systematic study of rat head motion parameters for unanaesthetized tube-bound and freely moving rats with a view to designing suitable motion-tracking set-ups in each case. For tube-bound rats, using a single appropriately placed binocular tracker, uninterrupted tracking was possible greater than 95 per cent of the time. For freely moving rats, simulations and measurements of a live subject indicated that two opposed binocular trackers are sufficient (less than 10% interruption to tracking) for a wide variety of behaviour types. We conclude that reliable tracking of head pose can be achieved with marker-based optical-motion-tracking systems for both tube-bound and freely moving rats undergoing PET studies without sedation. PMID:22718992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angelis, Georgios I., E-mail: georgios.angelis@sydney.edu.au; Ryder, William J.; Bashar, Rezaul
Purpose: Single photon emission computed tomography (SPECT) brain imaging of freely moving small animals would allow a wide range of important neurological processes and behaviors to be studied, which are normally inhibited by anesthetic drugs or precluded due to the animal being restrained. While rigid body motion of the head can be tracked and accounted for in the reconstruction, activity in the torso may confound brain measurements, especially since motion of the torso is more complex (i.e., nonrigid) and not well correlated with that of the head. The authors investigated the impact of mispositioned events and attenuation due to themore » torso on the accuracy of motion corrected brain images of freely moving mice. Methods: Monte Carlo simulations of a realistic voxelized mouse phantom and a dual compartment phantom were performed. Each phantom comprised a target and an extraneous compartment which were able to move independently of each other. Motion correction was performed based on the known motion of the target compartment only. Two SPECT camera geometries were investigated: a rotating single head detector and a stationary full ring detector. The effects of motion, detector geometry, and energy of the emitted photons (hence, attenuation) on bias and noise in reconstructed brain regions were evaluated. Results: The authors observed two main sources of bias: (a) motion-related inconsistencies in the projection data and (b) the mismatch between attenuation and emission. Both effects are caused by the assumption that the orientation of the torso is difficult to track and model, and therefore cannot be conveniently corrected for. The motion induced bias in some regions was up to 12% when no attenuation effects were considered, while it reached 40% when also combined with attenuation related inconsistencies. The detector geometry (i.e., rotating vs full ring) has a big impact on the accuracy of the reconstructed images, with the full ring detector being more advantageous. Conclusions: Motion-induced inconsistencies in the projection data and attenuation/emission mismatch are the two main causes of bias in reconstructed brain images when there is complex motion. It appears that these two factors have a synergistic effect on the qualitative and quantitative accuracy of the reconstructed images.« less
Lovelock, D. Michael; Mechalakos, James; Rao, Shyam; Della‐Biancia, Cesar; Amols, Howard; Lee, Nancy
2013-01-01
To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an “open‐face” thermoplastic mask was evaluated using video‐based optical surface imaging (OSI) and kilovoltage (kV) X‐ray radiography. A three‐point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real‐time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15 minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open‐face and full‐head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open‐face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real‐time OSI. With the open‐face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre‐/post‐treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask‐locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open‐face and full‐head masks were found to be similar. Most (80%) of the volunteers preferred the open‐face mask to the full‐head mask, while claustrophobic patients could only tolerate the open‐face mask. The open‐face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open‐face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full‐head mask. PACS numbers: 87.19.xj, 87.63.L‐, 87.59.‐e, 87.55.tg, 87.55.‐x PMID:24036878
NASA Astrophysics Data System (ADS)
Almubarak, Yara; Tadesse, Yonas
2017-04-01
The potential applications of humanoid robots in social environments, motivates researchers to design, and control biomimetic humanoid robots. Generally, people are more interested to interact with robots that have similar attributes and movements to humans. The head is one of most important part of any social robot. Currently, most humanoid heads use electrical motors, pneumatic actuators, and shape memory alloy (SMA) actuators for actuation. Electrical and pneumatic actuators take most of the space and would cause unsmooth motions. SMAs are expensive to use in humanoids. Recently, in many robotic projects, Twisted and Coiled Polymer (TCP) artificial muscles are used as linear actuators which take up little space compared to the motors. In this paper, we will demonstrate the designing process and motion control of a robotic head with TCP muscles. Servo motors and artificial muscles are used for actuating the head motion, which have been controlled by a cost efficient ARM Cortex-M7 based development board. A complete comparison between the two actuators is presented.
The Effect of Soft and Rigid Cervical Collars on Head and Neck Immobilization in Healthy Subjects.
Barati, Kourosh; Arazpour, Mokhtar; Vameghi, Roshanak; Abdoli, Ali; Farmani, Farzad
2017-06-01
Whiplash injury is a prevalent and often destructive injury of the cervical column, which can lead to serious neck pain. Many approaches have been suggested for the treatment of whiplash injury, including anti-inflammatory drugs, manipulation, supervised exercise, and cervical collars. Cervical collars are generally divided into two groups: soft and rigid collars. The present study aimed to compare the effect of soft and rigid cervical collars on immobilizing head and neck motion. Many studies have investigated the effect of collars on neck motion. Rigid collars have been shown to provide more immobilization in the sagittal and transverse planes compared with soft collars. However, according to some studies, soft and rigid collars provide the same range of motion in the frontal plane. Twenty-nine healthy subjects aged 18-26 participated in this study. Data were collected using a three-dimensional motion analysis system and six infrared cameras. Eight markers, weighing 4.4 g and thickened 2 cm 2 were used to record kinematic data. According to the normality of the data, a paired t -test was used for statistical analyses. The level of significance was set at α=0.01. All motion significantly decreased when subjects used soft collars ( p <0.01). According to the obtained data, flexion and lateral rotation experienced the maximum (39%) and minimum (11%) immobilization in all six motions using soft collars. Rigid collars caused maximum immobilization in flexion (59%) and minimum immobilization in the lateral rotation (18%) and limited all motion much more than the soft collar. This study showed that different cervical collars have different effects on neck motion. Rigid and soft cervical collars used in the present study limited the neck motion in both directions. Rigid collars contributed to significantly more immobilization in all directions.
Dynamics of particles accelerated by head-on collisions of two magnetized plasma shocks
NASA Astrophysics Data System (ADS)
Takeuchi, Satoshi
2018-02-01
A kinetic model of the head-on collision of two magnetized plasma shocks is analyzed theoretically and in numerical calculations. When two plasmas with anti-parallel magnetic fields collide, they generate magnetic reconnection and form a motional electric field at the front of the collision region. This field accelerates the particles sandwiched between both shock fronts to extremely high energy. As they accelerate, the particles are bent by the transverse magnetic field crossing the magnetic neutral sheet, and their energy gains are reduced. In the numerical calculations, the dynamics of many test particles were modeled through the relativistic equations of motion. The attainable energy gain was obtained by multiplying three parameters: the propagation speed of the shock, the magnitude of the magnetic field, and the acceleration time of the test particle. This mechanism for generating high-energy particles is applicable over a wide range of spatial scales, from laboratory to interstellar plasmas.
Symeonidou, Evangelia-Regkina; Nordin, Andrew D; Hairston, W David; Ferris, Daniel P
2018-04-03
More neuroscience researchers are using scalp electroencephalography (EEG) to measure electrocortical dynamics during human locomotion and other types of movement. Motion artifacts corrupt the EEG and mask underlying neural signals of interest. The cause of motion artifacts in EEG is often attributed to electrode motion relative to the skin, but few studies have examined EEG signals under head motion. In the current study, we tested how motion artifacts are affected by the overall mass and surface area of commercially available electrodes, as well as how cable sway contributes to motion artifacts. To provide a ground-truth signal, we used a gelatin head phantom with embedded antennas broadcasting electrical signals, and recorded EEG with a commercially available electrode system. A robotic platform moved the phantom head through sinusoidal displacements at different frequencies (0-2 Hz). Results showed that a larger electrode surface area can have a small but significant effect on improving EEG signal quality during motion and that cable sway is a major contributor to motion artifacts. These results have implications in the development of future hardware for mobile brain imaging with EEG.
Decreased susceptibility to motion sickness during exposure to visual inversion in microgravity
NASA Technical Reports Server (NTRS)
Lackner, James R.; Dizio, Paul
1991-01-01
Head and body movements made in microgravity tend to bring on symptoms of motion sickness. Such head movements, relative to comparable ones made on earth, are accompanied by unusual combinations of semicircular canal and otolith activity owing to the unloading of the otoliths in 0G. Head movements also bring on symptoms of motion sickness during exposure to visual inversion (or reversal) on earth because the vestibulo-ocular reflex is rendered anti-compensatory. Here, evidence is presented that susceptibility to motion sickness during exposure to visual inversion is decreased in a 0G relative to 1G force background. This difference in susceptibility appears related to the alteration in otolith function in 0G. Some implications of this finding for the etiology of space motion sickness are described.
Power, Jonathan D; Plitt, Mark; Kundu, Prantik; Bandettini, Peter A; Martin, Alex
2017-01-01
Head motion can be estimated at any point of fMRI image processing. Processing steps involving temporal interpolation (e.g., slice time correction or outlier replacement) often precede motion estimation in the literature. From first principles it can be anticipated that temporal interpolation will alter head motion in a scan. Here we demonstrate this effect and its consequences in five large fMRI datasets. Estimated head motion was reduced by 10-50% or more following temporal interpolation, and reductions were often visible to the naked eye. Such reductions make the data seem to be of improved quality. Such reductions also degrade the sensitivity of analyses aimed at detecting motion-related artifact and can cause a dataset with artifact to falsely appear artifact-free. These reduced motion estimates will be particularly problematic for studies needing estimates of motion in time, such as studies of dynamics. Based on these findings, it is sensible to obtain motion estimates prior to any image processing (regardless of subsequent processing steps and the actual timing of motion correction procedures, which need not be changed). We also find that outlier replacement procedures change signals almost entirely during times of motion and therefore have notable similarities to motion-targeting censoring strategies (which withhold or replace signals entirely during times of motion).
Plitt, Mark; Kundu, Prantik; Bandettini, Peter A.; Martin, Alex
2017-01-01
Head motion can be estimated at any point of fMRI image processing. Processing steps involving temporal interpolation (e.g., slice time correction or outlier replacement) often precede motion estimation in the literature. From first principles it can be anticipated that temporal interpolation will alter head motion in a scan. Here we demonstrate this effect and its consequences in five large fMRI datasets. Estimated head motion was reduced by 10–50% or more following temporal interpolation, and reductions were often visible to the naked eye. Such reductions make the data seem to be of improved quality. Such reductions also degrade the sensitivity of analyses aimed at detecting motion-related artifact and can cause a dataset with artifact to falsely appear artifact-free. These reduced motion estimates will be particularly problematic for studies needing estimates of motion in time, such as studies of dynamics. Based on these findings, it is sensible to obtain motion estimates prior to any image processing (regardless of subsequent processing steps and the actual timing of motion correction procedures, which need not be changed). We also find that outlier replacement procedures change signals almost entirely during times of motion and therefore have notable similarities to motion-targeting censoring strategies (which withhold or replace signals entirely during times of motion). PMID:28880888
Idiopathic Avascular Necrosis of First Metatarsal Head in a Pediatric Patient.
Kwon, Young-Uk; Choi, Jang-Seok; Kong, Gyu-Min; Ha, Byung-Ho
Idiopathic avascular necrosis of the first metatarsal head rarely occurs in pediatrics. The present case of avascular necrosis of the first metatarsal head occurred in a 13-year-old male who came to the clinic with a 9-month history of pain in the first metatarsophalangeal joint. Conservative treatment had been applied for 9 months, but the pain had not been relieved. Therefore, surgical treatment, including decompression and debridement, was performed in the first metatarsal head of the patient. After 6 months of follow-up monitoring, full range of motion of the first metatarsophalangeal joint was observed, and the pain had disappeared. No any other complications had developed during 18 months of follow-up monitoring. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Reconstruction of head impacts in FIS World Cup alpine skiing.
Steenstrup, Sophie Elspeth; Mok, Kam-Ming; McIntosh, Andrew S; Bahr, Roald; Krosshaug, Tron
2018-06-01
Prior to the 2013/2014 season, the International Ski Federation (FIS) increased the helmet testing speed from 5.4 to 6.8 m/s for alpine downhill, super-G and giant slalom. Whether this increased testing speed reflects head impact velocities in real head injury situations on snow is unclear. We therefore investigated the injury mechanisms and gross head impact biomechanics in seven real head injury situations among World Cup (WC) alpine skiers. We analysed nine head impacts from seven head injury videos from the FIS Injury Surveillance System, throughout nine WC seasons (2006-2015) in detail. We used commercial video-based motion analysis software to estimate head impact kinematics in two dimensions, including directly preimpact and postimpact, from broadcast video. The sagittal plane angular movement of the head was also measured using angle measurement software. In seven of nine head impacts, the estimated normal to slope preimpact velocity was higher than the current FIS helmet rule of 6.8 m/s (mean 8.1 (±SD 0.6) m/s, range 1.9±0.8 to 12.1±0.4 m/s). The nine head impacts had a mean normal to slope velocity change of 9.3±1.0 m/s, range 5.2±1.1 to 13.5±1.3 m/s. There was a large change in sagittal plane angular velocity (mean 43.3±2.9 rad/s (range 21.2±1.5 to 64.2±3.0 rad/s)) during impact. The estimated normal to slope preimpact velocity was higher than the current FIS helmet rule of 6.8 m/s in seven of nine head impacts. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Ros, Ivo G; Biewener, Andrew A
2017-01-01
Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades), and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles.
Ros, Ivo G.; Biewener, Andrew A.
2017-01-01
Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades), and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles. PMID:29249929
Modeling depth from motion parallax with the motion/pursuit ratio
Nawrot, Mark; Ratzlaff, Michael; Leonard, Zachary; Stroyan, Keith
2014-01-01
The perception of unambiguous scaled depth from motion parallax relies on both retinal image motion and an extra-retinal pursuit eye movement signal. The motion/pursuit ratio represents a dynamic geometric model linking these two proximal cues to the ratio of depth to viewing distance. An important step in understanding the visual mechanisms serving the perception of depth from motion parallax is to determine the relationship between these stimulus parameters and empirically determined perceived depth magnitude. Observers compared perceived depth magnitude of dynamic motion parallax stimuli to static binocular disparity comparison stimuli at three different viewing distances, in both head-moving and head-stationary conditions. A stereo-viewing system provided ocular separation for stereo stimuli and monocular viewing of parallax stimuli. For each motion parallax stimulus, a point of subjective equality (PSE) was estimated for the amount of binocular disparity that generates the equivalent magnitude of perceived depth from motion parallax. Similar to previous results, perceived depth from motion parallax had significant foreshortening. Head-moving conditions produced even greater foreshortening due to the differences in the compensatory eye movement signal. An empirical version of the motion/pursuit law, termed the empirical motion/pursuit ratio, which models perceived depth magnitude from these stimulus parameters, is proposed. PMID:25339926
Ivancic, Paul C
2013-06-01
In vitro biomechanical study. Our objective was to determine the effectiveness of cervical collars and cervicothoracic orthoses for stabilizing clinically relevant, experimentally produced cervical spine injuries. Most previous in vitro studies of cervical orthoses used a simplified injury model with all ligaments transected at a single spinal level, which differs from real-life neck injuries. Human volunteer studies are limited to measuring only sagittal motions or 3-dimensional motions only of the head or 1 or 2 spinal levels. Three-plane flexibility tests were performed to evaluate 2 cervical collars (Vista Collar and Vista Multipost Collar) and 2 cervicothoracic orthoses (Vista TS and Vista TS4) using a skull-neck-thorax model with 8 injured cervical spine specimens (manufacturer of orthoses: Aspen Medical Products Inc, Irvine, CA). The injuries consisted of flexion-compression at the lower cervical spine and extension-compression at superior spinal levels. Pair-wise repeated measures analysis of variance (P < 0.05) and Bonferroni post hoc tests determined significant differences in average range of motions of the head relative to the base, C7 or T1, among experimental conditions. RESULTS.: All orthoses significantly reduced unrestricted head/base flexion and extension. The orthoses allowed between 8.4% and 25.8% of unrestricted head/base motion in flexion/extension, 57.8% to 75.5% in axial rotation, and 53.8% to 73.7% in lateral bending. The average percentages of unrestricted motion allowed by the Vista Collar, Vista Multipost Collar, Vista TS, and Vista TS4 were: 14.0, 9.7, 6.1, and 4.7, respectively, for middle cervical spine extension and 13.2, 11.8, 3.3, and 0.4, respectively, for lower cervical spine flexion. Successive increases in immobilization were observed from Vista Collar to Vista Multipost Collar, Vista TS, and Vista TS4 in extension at the injured middle cervical spine and in flexion at the injured lower cervical spine. Our results may assist clinicians in selecting the most appropriate orthosis based upon patient-specific cervical spine injuries.
Glenohumeral Function of the Long Head of the Biceps Muscle
Chalmers, Peter N.; Cip, Johannes; Trombley, Robert; Cole, Brian J.; Wimmer, Markus A.; Romeo, Anthony A.; Verma, Nikhil N.
2014-01-01
Background: Optimal treatment of superior labral anterior-posterior (SLAP) tears is controversial, in part because the dynamic role of the long head of the biceps muscle (LHBM) in the glenohumeral joint is unclear. The aim of this study was to determine dynamic LHBM behavior during shoulder activity by studying (1) the electromyographic activity of the LHBM during shoulder motion, (2) the effect of elbow immobilization on this activity, and (3) the effect of a load applied to the distal humerus on this activity. Hypothesis: The LHBM would not play a significant role in active glenohumeral range of motion. Study Design: Controlled laboratory study. Methods: Thirteen normal volunteers underwent surface electromyography (EMG) measurement of the LHBM, short head biceps muscle (SHBM), deltoid, infraspinatus, and brachioradialis during shoulder motion from the neutral position (0° of rotation, flexion, and abduction) to 45° of flexion, 90° of flexion, 45° of abduction, and 90° of abduction. These motions were repeated both with and without splint immobilization of the forearm and elbow at 100° of flexion and neutral rotation and with and without a 1-kg weight placed on the lateral distal humerus. Results: Mean EMG activity within the LHBM and the SHBM was low (≤11.6% ± 9.1%). LHBM activity was significant increased by flexion and abduction (P < .049 in all cases), while SHBM activity was not. EMG activity from the middle head of the deltoid was significantly increased by loading with the shoulder positioned away from the body (ie, in abduction or flexion). When compared with the unloaded state, the addition of a distal humeral load significantly increased LHBM activity in 45° of abduction (P = .028) and 90° of flexion (P = .033) despite forearm and elbow immobilization. The SHBM showed similar trends. Conclusion: In normal volunteers with forearm and elbow immobilization and application of a load to the distal humerus, LHBM EMG activity is increased by both glenohumeral flexion and abduction, suggesting that this muscle plays a dynamic role in glenohumeral motion with higher demand activities. Clinical Relevance: Biceps tenodesis may result in dynamic change within the glenohumeral joint with higher demand activities. PMID:26535304
Improved frame-based estimation of head motion in PET brain imaging.
Mukherjee, J M; Lindsay, C; Mukherjee, A; Olivier, P; Shao, L; King, M A; Licho, R
2016-05-01
Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.
The relation of motion sickness to the spatial-temporal properties of velocity storage
NASA Technical Reports Server (NTRS)
Dai, Mingjia; Kunin, Mikhail; Raphan, Theodore; Cohen, Bernard; Young, L. R. (Principal Investigator)
2003-01-01
Tilting the head in roll to or from the upright while rotating at a constant velocity (roll while rotating, RWR) alters the position of the semicircular canals relative to the axis of rotation. This produces vertical and horizontal nystagmus, disorientation, vertigo, and nausea. With recurrent exposure, subjects habituate and can make more head movements before experiencing overpowering motion sickness. We questioned whether promethazine lessened the vertigo or delayed the habituation, whether habituation of the vertigo was related to the central vestibular time constant, i.e., to the time constant of velocity storage, and whether the severity of the motion sickness was related to deviation of the axis of eye velocity from gravity. Sixteen subjects received promethazine and placebo in a double-blind, crossover study in two consecutive 4-day test series 1 month apart, termed series I and II. Horizontal and vertical eye movements were recorded with video-oculography while subjects performed roll head movements of approx. 45 degrees over 2 s to and from the upright position while being rotated at 138 degrees /s around a vertical axis. Motion sickness was scaled from 1 (no sickness) to an endpoint of 20, at which time the subject was too sick to continue or was about to vomit. Habituation was determined by the number of head movements that subjects made before reaching the maximum motion sickness score of 20. Head movements increased steadily in each session with repeated testing, and there was no difference between the number of head movements made by the promethazine and placebo groups. Horizontal and vertical angular vestibulo-ocular reflex (aVOR) time constants declined in each test, with the declines being closely correlated to the increase in the number of head movements. The strength of vertiginous sensation was associated with the amount of deviation of the axis of eye velocity from gravity; the larger the deviation of the eye velocity axis from gravity, the more severe the motion sickness. Thus, promethazine neither reduced the nausea associated with RWR, nor retarded or hastened habituation. The inverse relationship between the aVOR time constants and number of head movements to motion sickness, and the association of the severity of motion sickness with the extent, strength, and time of deviation of eye velocity from gravity supports the postulate that the spatiotemporal properties of velocity storage, which are processed between the nodulus and uvula of the vestibulocerebellum and the vestibular nuclei, are likely to represent the source of the conflict responsible for producing motion sickness.
Symeonidou, Evangelia-Regkina; Nordin, Andrew D.; Hairston, W. David
2018-01-01
More neuroscience researchers are using scalp electroencephalography (EEG) to measure electrocortical dynamics during human locomotion and other types of movement. Motion artifacts corrupt the EEG and mask underlying neural signals of interest. The cause of motion artifacts in EEG is often attributed to electrode motion relative to the skin, but few studies have examined EEG signals under head motion. In the current study, we tested how motion artifacts are affected by the overall mass and surface area of commercially available electrodes, as well as how cable sway contributes to motion artifacts. To provide a ground-truth signal, we used a gelatin head phantom with embedded antennas broadcasting electrical signals, and recorded EEG with a commercially available electrode system. A robotic platform moved the phantom head through sinusoidal displacements at different frequencies (0–2 Hz). Results showed that a larger electrode surface area can have a small but significant effect on improving EEG signal quality during motion and that cable sway is a major contributor to motion artifacts. These results have implications in the development of future hardware for mobile brain imaging with EEG. PMID:29614020
Psychophysical estimation of the effects of aging on direction-of-heading judgments
NASA Astrophysics Data System (ADS)
Raghuram, Aparna; Lakshminarayanan, Vasudevan
2011-11-01
We conducted psychophysical experiments on direction-of-heading judgments using old and young subjects. Subjects estimated heading directions on a translation perpendicular to the vertical plane (frontoparallel); we found that heading judgments were affected by age. Increasing the random dot density in the stimulus from 24 to 400 dots did not improve threshold significantly. Older subjects started performing worse at the highest dots condition of 400. The speed of the radial motion was important, as heading judgments with slower radial motion were difficult to judge than faster radial motion, as the focus of expansion was easier to locate owing to the larger displacement of dots. Gender differences indicated that older women had a higher threshold than older men. This was only significant for the faster simulated radial speed. A general trend of women having a higher threshold than men was noticed.
Circi, E; Tuzuner, T; Sukur, E; Baris, A; Kanay, E
2016-08-01
This study looks at the failure and complications arising secondary to resurfacing and hemi-arthroplasty done at the metatarsal head in patients with hallux rigidus. Our report includes a review of the relevant literature to verify the validity of our techniques. We performed metatarsal head resurfacing with hemi-arthroplasty using the HemiCap(®), on 12 patients with hallux rigidus between the dates of March 2010 and October 2013. The mean follow-up period was 22.3 months (range 12-54). All patients were clinically and radiologically evaluated according to the American Orthopedics Foot and Ankle Society (AOFAS) functional scale and the Coughlin and Shurnas classification. The recorded mean AOFAS score showed an increase from the preoperative score of 49.2 ± 13.1 to a postoperative follow-up score of 80.8 ± 13.1 (p < 0.001). Pain scores also showed an improvement from 16.5 ± 7.1 points preoperatively to 32.5 ± 6.9 points during the postoperative follow-up (p < 0.001). The mean function score improved from 17.7 ± 7.6 points preoperatively to 33.2 ± 7.6 points during the final postoperative follow-up (p < 0.001). Furthermore, the mean range of motion improved from 16.3 ± 4.8° preoperatively to 45.4 ± 13.2° postoperatively (p < 0.001). Three patients (25 %) reported pain at rest. Surgical revision was done on these patients who have significant pain that limited their range of motion. Favorable outcomes were achieved by performing minimal bone resection which also helps maintain metatarso-phalangeal joint function through metatarsal head resurfacing arthroplasty. We expect the failure rates to decrease with the advancements of surgical techniques. Selecting the appropriate patient populous in the application of the technique is crucial in attaining successful clinical results.
Surgical hip dislocation for treatment of cam femoroacetabular impingement
Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, KN; KoKo, Aung; Zaw, Than; Siddhartha, A
2015-01-01
Background: Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Materials and Methods: Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Results: Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°–108°) to 46.35° (range 39°–58°). Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term. PMID:26538754
The working mechanism of manual therapy in participants with chronic tension-type headache.
Castien, René; Blankenstein, Annette; van der Windt, Daniëlle; Heymans, Martijn W; Dekker, Joost
2013-10-01
Prospective longitudinal study. To explore the working mechanism of manual therapy, we investigated whether 3 cervical spine variables were mediators of the effect of manual therapy on headache frequency. Background Manual therapy has been shown to reduce headache frequency in participants with chronic tension-type headache (CTTH). To what extent specific elements of treatment contribute to the effectiveness of manual therapy in CTTH is unknown. One hundred eighty-two participants with CTTH participated in a prospective longitudinal study: 142 underwent manual therapy and 40 participants received usual care by their general practitioner. Regression analysis was performed according to the steps described by Baron and Kenny, and the proportion of mediated effect was estimated for 3 potential mediators: (1) cervical range of motion, (2) neck flexor endurance, and (3) forward head posture. Outcome was defined as a 50% or greater reduction in headache days. Neck flexor endurance mediated 24.5% of the effect of manual therapy. Cervical range of motion and forward head posture showed no mediated effect. Increased neck flexor endurance appears to be a working mechanism of manual therapy. This finding supports isometric training of neck flexors in participants with CTTH. Trial registered with Netherlands Trial Register (TR 1074).
Shin, Young Jun; Kim, Won Hyo; Kim, Seong Gil
2017-08-01
This study investigated the correlation between the neck disability index (NDI) and visual analogue scale (VAS), which are indicators of neck pain, shoulder joint range of motion (ROM), and muscle strength in women with a slight forward head posture. This study was carried out on 42 female college students attending Uiduk University in Gyeongju, Korea. The neck pain and disability index for each subject was measured using VAS and NDI, respectively. Two physiotherapists measured the shoulder joint ROM and muscle strengths of the subjects using a goniometer and a dynamometer, respectively. External rotation, internal rotation, and abduction of the shoulder joint were measured for each subject. A significant negative correlation between neck pain and shoulder joint ROM in external rotation and the muscle strength of the shoulder joint in abduction was found in the subjects. In addition, a significant positive correlation was observed between ROM in external rotation and muscle strength in abduction. This study showed a significant negative correlation between neck pain and ROM in external rotation as well as between neck pain and the muscle strength in abduction.
Dugailly, Pierre-Michel; De Santis, Roberta; Tits, Mathieu; Sobczak, Stéphane; Vigne, Anna; Feipel, Véronique
2015-12-01
Cervicocephalic kinesthetic deficiencies have been demonstrated in patients with chronic neck pain (NP). On the other hand, authors emphasized the use of different motion speeds for assessing functional impairment of the cervical spine. The objectives of this study were (1) to investigate the head repositioning accuracy in NP patients and control subjects and (2) to assess the influence of target distance, motion speed, motion direction and pain. Seventy-one subjects (36 healthy subjects and 35 NP patients; age 30-55 years) performed the head repositioning test (HRT) at two different speeds for horizontal and vertical movements and at two different distances. For each condition, six consecutive trials were sampled. The study showed the validity and reproducibility of the HRT, confirming a dysfunctional threshold of 4.5°. Normative values of head repositioning error up to 3.6° and 7.1° were identified for healthy and NP subjects, respectively. A distance of 180 cm from the target and a natural motion speed increased HRT accuracy. Repositioning after extension movement showed a significantly larger error in both groups. Intensity, duration of pain as well as pain level did not significantly alter head repositioning error. The assessment of proprioceptive performance in healthy and NP subjects allowed the validation of the HRT. The HRT is a simple, not expensive and fast test, easily implementable in daily practice to assess and monitor treatment and evolution of proprioceptive cervical deficits.
Head repositioning accuracy in patients with whiplash-associated disorders.
Feipel, Veronique; Salvia, Patrick; Klein, Helene; Rooze, Marcel
2006-01-15
Controlled study, measuring head repositioning error (HRE) using an electrogoniometric device. To compare HRE in neutral position, axial rotation and complex postures of patients with whiplash-associated disorders (WAD) to that of control subjects. The presence of kinesthetic alterations in patients with WAD is controversial. In 26 control subjects and 29 patients with WAD (aged 22-74 years), head kinematics was sampled using a 3-dimensional electrogoniometer mounted using a harness and a helmet. All tasks were realized in seated position. The repositioning tasks included neutral repositioning after maximal flexion-extension, eyes open and blindfolded, repositioning at 50 degrees of axial rotation, and repositioning at 50 degrees of axial rotation combined to 20 degrees of ipsilateral bending. The flexion-extension, ipsilateral bending, and axial rotation components of HRE were considered. A multiple-way repeated-measures analysis of variance was used to compare tasks and groups. The WAD group displayed a reduced flexion-extension range (P = 1.9 x 10(-4)), and larger HRE during flexion-extension and repositioning tasks (P = 0.009) than controls. Neither group nor task affected maximal motion velocity. Neutral HRE of the flexion-extension component was larger in blindfolded condition (P = 0.03). Ipsilateral bending and axial rotation HRE components were smaller than the flexion-extension component (P = 7.1 x 10(-23)). For pure rotation repositioning, axial rotation HRE was significantly larger than flexion-extension and ipsilateral bending repositioning error (P = 3.0 x 10(-23)). Ipsilateral bending component of HRE was significantly larger combined tasks than for pure rotation tasks (P = 0.004). In patients with WAD, range of motion and head repositioning accuracy were reduced. However, the differences were small. Vision suppression and task type influenced HRE.
Postburn Head and Neck Reconstruction: An Algorithmic Approach.
Heidekrueger, Paul Immanuel; Broer, Peter Niclas; Tanna, Neil; Ninkovic, Milomir
2016-01-01
Optimizing functional and aesthetic outcomes in postburn head and neck reconstruction remains a surgical challenge. Recurrent contractures, impaired range of motion, and disfigurement because of disruption of the aesthetic subunits of the face, can result in poor patient satisfaction and ultimately, contribute to social isolation of the patient. In an effort to improve the quality of life of these patients, this study evaluates different surgical approaches with an emphasis on tissue expansion of free and regional flaps. Regional and free-flap reconstruction was performed in 20 patients (26 flaps) with severe postburn head and neck contractures. To minimize donor site morbidity and obtain large amounts of thin and pliable tissue, pre-expansion was performed in all patients treated with locoregional flap reconstructions (12/12), and 62% (8/14) of patients with free-flap reconstructions. Algorithms regarding pre- and intraoperative decision-making are discussed, and complications between the techniques as well as long-term (mean follow-up 3 years) results are analyzed. Complications, including tissue expander infection with need for removal or exchange, partial or full flap loss, were evaluated and occurred in 25% (3/12) of patients with locoregional and 36% (5/14) of patients receiving free-flap reconstructions. Secondary revision surgery was performed in 33% (4/12) of locoregional flaps and 93% (13/14) of free flaps. Both locoregional as well as distant tissue transfers have their role in postburn head and neck reconstruction, whereas pre-expansion remains an invaluable tool. Paying attention to the presented principles and keeping the importance of aesthetic facial subunits in mind, range of motion, aesthetics, and patient satisfaction were improved long term in all our patients, while minimizing donor site morbidity.
Masjedi, Milad; Lovell, Cara; Johnson, Garth R
2011-12-01
Patients with rotator cuff tear and degenerative shoulder joint disease commonly experience severe pain and reduced performance during activities of daily living. A popular way to treat these patients is by means of reverse anatomy shoulder prosthesis. Studying the kinematics of subjects with reverse anatomy implant would be useful in order to gain knowledge about functionality of different designs. It is hypothesized that the kinematics of these subjects, in the absence of rotator cuff muscles, differs from that of normal subjects. In this study the upper limb kinematics of 12 subjects with a Bayley-Walker reverse anatomy shoulder prosthesis while performing tasks common in everyday activities and those that represent the range of motion was analyzed and compared to that of 12 normal subjects. Each patient also completed an Oxford Shoulder Score. Substantial reduction in the Bayley-Walker subjects' ranges of motion was observed compared to normal subjects. The mean abduction angle decreased from 109° (±20) for normal subjects to 64° (±25). A similar trend was observed during flexion and axial rotation tasks. Furthermore, the normal group showed less variable ranges of motion performing the standard tasks, whereas for the prosthetic group this varied greatly, which is likely to be dependent on muscle strength. Although the decreased range of motion was prominent, subjects were able to complete most of the tasks by compensating with their elbow and trunk. The most challenging task for Bayley-Walker subjects was lifting an object to head height. Copyright © 2010 Elsevier B.V. All rights reserved.
Motion of the head and neck of female and male volunteers in rear impact car-to-car impacts.
Carlsson, Anna; Siegmund, Gunter P; Linder, Astrid; Svensson, Mats Y
2012-01-01
The objectives of this study were to quantify and compare dynamic motion responses between 50th percentile female and male volunteers in rear impact tests. These data are fundamental for developing future occupant models for crash safety development and assessment. High-speed video data from a rear impact test series with 21 male and 21 female volunteers at 4 and 8 km/h, originally presented in Siegmund et al. (1997), were used for further analysis. Data from a subset of female volunteers, 12 at 4 km/h and 9 at 8 km/h, were extracted from the original data set to represent the 50th percentile female. Their average height was 163 cm and their average weight was 62 kg. Among the male volunteers, 11 were selected, with an average height of 175 cm and an average weight of 73 kg, to represent the 50th percentile male. Response corridors were generated for the horizontal and angular displacements of the head, T1 (first thoracic vertebra), and the head relative to T1. T-tests were performed with the statistical significance level of .05 to quantify the significance of the differences in parameter values for the males and females. Several differences were found in the average motion response of the male and female volunteers at 4 and 8 km/h. Generally, females had smaller rearward horizontal and angular motions of the head and T1 compared to the males. This was mainly due to shorter initial head-to-head restraint distance and earlier head-to-head restraint contact for the females. At 8 km/h, the female volunteers showed 12 percent lower horizontal peak rearward head displacement (P = .018); 22 percent lower horizontal peak rearward head relative to T1 displacement (P = .018); and 30 percent lower peak head extension angle (P = .001). The females also had more pronounced rebound motion. This study indicates that there may be characteristic differences in the head-neck motion response between 50th percentile males and females in rear impacts. The exclusive use of 50th percentile male rear impact dummies may thus limit the assessment and development of whiplash prevention systems that adequately protect both male and female occupants. The results of this study could be used in the development and evaluation of a mechanical and/or computational average-sized female dummy model for rear impact safety assessment. These models are used in the development and evaluation of protective systems. It would be of interest to make further studies into seat configurations featuring a greater head-to-head restraint distance.
Automated reference-free detection of motion artifacts in magnetic resonance images.
Küstner, Thomas; Liebgott, Annika; Mauch, Lukas; Martirosian, Petros; Bamberg, Fabian; Nikolaou, Konstantin; Yang, Bin; Schick, Fritz; Gatidis, Sergios
2018-04-01
Our objectives were to provide an automated method for spatially resolved detection and quantification of motion artifacts in MR images of the head and abdomen as well as a quality control of the trained architecture. T1-weighted MR images of the head and the upper abdomen were acquired in 16 healthy volunteers under rest and under motion. Images were divided into overlapping patches of different sizes achieving spatial separation. Using these patches as input data, a convolutional neural network (CNN) was trained to derive probability maps for the presence of motion artifacts. A deep visualization offers a human-interpretable quality control of the trained CNN. Results were visually assessed on probability maps and as classification accuracy on a per-patch, per-slice and per-volunteer basis. On visual assessment, a clear difference of probability maps was observed between data sets with and without motion. The overall accuracy of motion detection on a per-patch/per-volunteer basis reached 97%/100% in the head and 75%/100% in the abdomen, respectively. Automated detection of motion artifacts in MRI is feasible with good accuracy in the head and abdomen. The proposed method provides quantification and localization of artifacts as well as a visualization of the learned content. It may be extended to other anatomic areas and used for quality assurance of MR images.
ERIC Educational Resources Information Center
Boker, Steven M.; Cohn, Jeffrey F.; Theobald, Barry-John; Matthews, Iain; Mangini, Michael; Spies, Jeffrey R.; Ambadar, Zara; Brick, Timothy R.
2011-01-01
During conversation, women tend to nod their heads more frequently and more vigorously than men. An individual speaking with a woman tends to nod his or her head more than when speaking with a man. Is this due to social expectation or due to coupled motion dynamics between the speakers? We present a novel methodology that allows us to randomly…
Sarig Bahat, Hilla; Chen, Xiaoqi; Reznik, David; Kodesh, Einat; Treleaven, Julia
2015-04-01
Chronic neck pain has been consistently shown to be associated with impaired kinematic control including reduced range, velocity and smoothness of cervical motion, that seem relevant to daily function as in quick neck motion in response to surrounding stimuli. The objectives of this study were: to compare interactive cervical kinematics in patients with neck pain and controls; to explore the new measures of cervical motion accuracy; and to find the sensitivity, specificity, and optimal cutoff values for defining impaired kinematics in those with neck pain. In this cross-section study, 33 patients with chronic neck pain and 22 asymptomatic controls were assessed for their cervical kinematic control using interactive virtual reality hardware and customized software utilizing a head mounted display with built-in head tracking. Outcome measures included peak and mean velocity, smoothness (represented by number of velocity peaks (NVP)), symmetry (represented by time to peak velocity percentage (TTPP)), and accuracy of cervical motion. Results demonstrated significant and strong effect-size differences in peak and mean velocities, NVP and TTPP in all directions excluding TTPP in left rotation, and good effect-size group differences in 5/8 accuracy measures. Regression results emphasized the high clinical value of neck motion velocity, with very high sensitivity and specificity (85%-100%), followed by motion smoothness, symmetry and accuracy. These finding suggest cervical kinematics should be evaluated clinically, and screened by the provided cut off values for identification of relevant impairments in those with neck pain. Such identification of presence or absence of kinematic impairments may direct treatment strategies and additional evaluation when needed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Gane, E M; Michaleff, Z A; Cottrell, M A; McPhail, S M; Hatton, A L; Panizza, B J; O'Leary, S P
2017-07-01
Shoulder pain and dysfunction may occur following neck dissection among people being treated for head and neck cancer. This systematic review aims to examine the prevalence and incidence of shoulder and neck dysfunction after neck dissection and identify risk factors for these post-operative complications. Electronic databases (Pubmed, CINAHL, EMBASE, Cochrane) were searched for articles including adults undergoing neck dissection for head and neck cancer. Studies that reported prevalence, incidence or risk factors for an outcome of the shoulder or neck were eligible and assessed using the Critical Review Form - Quantitative Studies. Seventy-five articles were included in the final review. Prevalence rates for shoulder pain were slightly higher after RND (range, 10-100%) compared with MRND (range, 0-100%) and SND (range, 9-25%). The incidence of reduced shoulder active range of motion depended on surgery type (range, 5-20%). The prevalence of reduced neck active range of motion after neck dissection was 1-13%. Type of neck dissection was a risk factor for shoulder pain, reduced function and health-related quality of life. The prevalence and incidence of shoulder and neck dysfunction after neck dissection varies by type of surgery performed and measure of dysfunction used. Pre-operative education for patients undergoing neck dissection should acknowledge the potential for post-operative shoulder and neck problems to occur and inform patients that accessory nerve preservation lowers, but does not eliminate, the risk of developing musculoskeletal complications. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Cheng, Xiaorong; Ge, Hui; Andoni, Deljfina; Ding, Xianfeng; Fan, Zhao
2015-01-01
A recent hierarchical model of numerical processing, initiated by Fischer and Brugger (2011) and Fischer (2012), suggested that situated factors, such as different body postures and body movements, can influence the magnitude representation and bias numerical processing. Indeed, Loetscher et al. (2008) found that participants’ behavior in a random number generation task was biased by head rotations. More small numbers were reported after leftward than rightward head turns, i.e., a motion-numerical compatibility effect. Here, by carrying out two experiments, we explored whether similar motion-numerical compatibility effects exist for movements of other important body components, e.g., arms, and for composite body movements as well, which are basis for complex human activities in many ecologically meaningful situations. In Experiment 1, a motion-numerical compatibility effect was observed for lateral rotations of two body components, i.e., the head and arms. Relatively large numbers were reported after making rightward compared to leftward movements for both lateral head and arm turns. The motion-numerical compatibility effect was observed again in Experiment 2 when participants were asked to perform composite body movements of congruent movement directions, e.g., simultaneous head left turns and arm left turns. However, it disappeared when the movement directions were incongruent, e.g., simultaneous head left turns and arm right turns. Taken together, our results extended Loetscher et al.’s (2008) finding by demonstrating that their effect is effector-general and exists for arm movements. Moreover, our study reveals for the first time that the impact of spatial information on numerical processing induced by each of the two sensorimotor-based situated factors, e.g., a lateral head turn and a lateral arm turn, can cancel each other out. PMID:26594188
Multi-Head Very High Power Strobe System For Motion Picture Special Effects
NASA Astrophysics Data System (ADS)
Lovoi, P. A.; Fink, Michael L.
1983-10-01
A very large camera synchronizable strobe system has been developed for motion picture special effects. This system, the largest ever built, was delivered to MGM/UA to be used in the movie "War Games". The system consists of 12 individual strobe heads and a power supply distribution system. Each strobe head operates independently and may be flashed up to 24 times per second under computer control. An energy of 480 Joules per flash is used in six strobe heads and 240 Joules per flash in the remaining six strobe heads. The beam pattern is rectangular with a FWHM of 60° x 48°.
Hip capsular thickness correlates with range of motion limitations in femoroacetabular impingement.
Zhang, Kailai; de Sa, Darren; Yu, Hang; Choudur, Hema Nalini; Simunovic, Nicole; Ayeni, Olufemi Rolland
2018-03-24
Femoroacetabular impingement (FAI) is a clinical entity of the hip causing derangements in range of motion, pain, gait, and function. Computer-assisted modeling and clinical studies suggest that patients with FAI have increased capsular thickness compared to those without.A retrospective chart review was performed to assess relationships between capsular thickness, hip range of motion, and demographic factors in patients with FAI. Local Research Ethics Board approval was obtained to extract electronic medical records for 188 patients at a single institution who had undergone hip arthroscopy. Procedures were performed from 2009 to 2017 by a single, fellowship-trained, board-certified sports medicine orthopaedic surgeon. Inclusion criteria were preoperative hip range of motion testing, positive clinical impingement testing, and magnetic resonance imaging (MRI) of the affected hip. Patient demographics, hip range of motion, and time to surgery were recorded. MRIs were reviewed by a board-certified musculoskeletal radiologist blinded to clinical data. Maximum thickness of the anterior hip capsule was measured in axial, axial oblique, and sagittal oblique sequences. Anterior capsular thickness was also measured at the level of the femoral head-neck junction in axial sequences (axial midline). Axial midline capsular thickness was negatively correlated with hip flexion (r = - 0.196, p = 0.0042) and internal rotation (r = - 0.143, p = 0.0278). Significant differences were seen between genders in axial midline thickness (5.3 ± 1.4 mm males/4.8 ± 1.3 mm females, p = 0.0079), flexion (113° ± 18° males/120° ± 17° females, p = 0.0029), and internal rotation (23° ± 13° males/29° ± 12° females, p = 0.0155). Significant differences also existed between side affected in flexion (116° ± 17° right/119° ± 17° left, p = 0.0396) and internal rotation (26° ± 12° right/29° ± 13° left, p = 0.0029). Positive correlation was observed between axial oblique capsular thickness and flexion (r = 0.2345) (p = 0.0229). Increased anterior hip capsular thickness at the femoral head-neck correlates with limitations in hip range of motion in FAI. The strength of this relationship may be affected between pathologies, genders, and affected side. Pathologic thickening of the hip capsule may contribute to restricted hip mobility on clinical examination, and elucidation of this relationship may provide guidance into capsular management during hip arthroscopy. 4, retrospective case series.
Trochanteric fracture-implant motion during healing - A radiostereometry (RSA) study.
Bojan, Alicja J; Jönsson, Anders; Granhed, Hans; Ekholm, Carl; Kärrholm, Johan
2018-03-01
Cut-out complication remains a major unsolved problem in the treatment of trochanteric hip fractures. A better understanding of the three-dimensional fracture-implant motions is needed to enable further development of clinical strategies and countermeasures. The aim of this clinical study was to characterise and quantify three-dimensional motions between the implant and the bone and between the lag screw and nail of the Gamma nail. Radiostereometry Analysis (RSA) analysis was applied in 20 patients with trochanteric hip fractures treated with an intramedullary nail. The following three-dimensional motions were measured postoperatively, at 1 week, 3, 6 and 12 months: translations of the tip of the lag screw in the femoral head, motions of the lag screw in the nail, femoral head motions relative to the nail and nail movements in the femoral shaft. Cranial migration of the tip of the lag screw dominated over the other two translation components in the femoral head. In all fractures the lag screw slid laterally in the nail and the femoral head moved both laterally and inferiorly towards the nail. All femoral heads translated posteriorly relative to the nail, and rotations occurred in both directions with median values close to zero. The nail tended to retrovert in the femoral shaft. Adverse fracture-implant motions were detected in stable trochanteric hip fractures treated with intramedullary nails with high resolution. Therefore, RSA method can be used to evaluate new implant designs and clinical strategies, which aim to reduce cut-out complications. Future RSA studies should aim at more unstable fractures as these are more likely to fail with cut-out. Copyright © 2018 Elsevier Ltd. All rights reserved.
Improved frame-based estimation of head motion in PET brain imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukherjee, J. M., E-mail: joyeeta.mitra@umassmed.edu; Lindsay, C.; King, M. A.
Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition ismore » uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.« less
Improved frame-based estimation of head motion in PET brain imaging
Mukherjee, J. M.; Lindsay, C.; Mukherjee, A.; Olivier, P.; Shao, L.; King, M. A.; Licho, R.
2016-01-01
Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type. PMID:27147355
Research study on neck injury lessening with active head restraint using human body FE model.
Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji
2008-12-01
The objective of this study is to examine the effectiveness of the active head restraint system in reducing neck injury risk of car occupants in low-speed rear impacts. A human body FE model "THUMS" was used to simulate head and neck kinematics of the occupant and to evaluate loading to the neck. Joint capsule strain was calculated to predict neck injury risk as well as NIC. The validity of the model was confirmed comparing its mechanical responses to those in human subjects in the literatures. Seat FE models were also prepared representing one with a fixed head restraint and the other one with an active head restraint system. The active head restraint system was designed to move the head restraint forward and upward when the lower unit was lower unit was loaded by the pelvis. Rear impact simulations were performed assuming a triangular acceleration pulse at a delta-V of 25 km/h. The model reproduced similar head and neck motions to those measured in the human volunteer test, except for active muscular responses. The calculated joint capsule strain also showed a good match with those of PMHS tests in the literature. A rear-impact simulation was conducted using the model with the fixed head restraint. The result revealed that NIC was strongly correlated with the relative acceleration between the head and the torso and that its maximum peak appeared when the head contacted the head restraint. It was also found that joint capsule strain grew in later timing synchronizing with the relative displacement. Another simulation with the active head restraint system showed that both NIC and joint capsule strain were lowered owing to the forward and upward motion of the head restraint. A close investigation of the vertebral motion indicated that the active head restraint reduced the magnitude of shear deformation in the facet joint, which contributed to the strain growth in the fixed head restraint case. Rear-impact simulations were conducted using a human body FE model, THUMS, representing an average-size male occupant. The cervical system including the facet joint capsules was incorporated to the model. The validity of the model was examined comparing its mechanical responses to those in the literature such as the whole body motion of the volunteer subject and the vertebral motion in the PMHS tests. Rear-impact simulations were conducted using the validated THUMS model and two prototype seat models; one had a fixed head restraint and the other one was equipped with an active head restraint system. The active head restraint system works moving the head restraint forward and upward when the lower unit is loaded by the pelvis. The head and neck kinematics and responses were analyzed from the simulation results. The force and acceleration rose at the pelvis first, followed by T1 and the head. The early timing of force rise and its magnitude indicated that the pelvis force was a good trigger for the active head restraint system. The results showed that the head was supported earlier in a case with the active head restraint system, and both NIC and joint capsule strain were lowered. The study also analyzed the mechanism of strain growth in the joint capsules. Relatively greater strain was observed in the direction of the facet joint surface, which was around 45 degrees inclined to the spinal column. The forward and upward motion of the active head restraint were aligned with the direction of the joint deformation and contributed to lower strain in the joint capsules. The results indicated that the active head restraint could help reduce the neck injury risk not only by supporting the head at an early timing but also through its trajectory stopping the joint deformation.
Kim, HyungGoo R.; Pitkow, Xaq; Angelaki, Dora E.
2016-01-01
Sensory input reflects events that occur in the environment, but multiple events may be confounded in sensory signals. For example, under many natural viewing conditions, retinal image motion reflects some combination of self-motion and movement of objects in the world. To estimate one stimulus event and ignore others, the brain can perform marginalization operations, but the neural bases of these operations are poorly understood. Using computational modeling, we examine how multisensory signals may be processed to estimate the direction of self-motion (i.e., heading) and to marginalize out effects of object motion. Multisensory neurons represent heading based on both visual and vestibular inputs and come in two basic types: “congruent” and “opposite” cells. Congruent cells have matched heading tuning for visual and vestibular cues and have been linked to perceptual benefits of cue integration during heading discrimination. Opposite cells have mismatched visual and vestibular heading preferences and are ill-suited for cue integration. We show that decoding a mixed population of congruent and opposite cells substantially reduces errors in heading estimation caused by object motion. In addition, we present a general formulation of an optimal linear decoding scheme that approximates marginalization and can be implemented biologically by simple reinforcement learning mechanisms. We also show that neural response correlations induced by task-irrelevant variables may greatly exceed intrinsic noise correlations. Overall, our findings suggest a general computational strategy by which neurons with mismatched tuning for two different sensory cues may be decoded to perform marginalization operations that dissociate possible causes of sensory inputs. PMID:27334948
Haddad, Cinira Assad Simão; Saad, Marcelo; Perez, Maria del Carmen Janeiro; Miranda, Fausto
2013-01-01
ABSTRACT Objective: To evaluate alterations in posture and range of motion of the upper limbs in women after mastectomy and lymphadenectomy, submitted to radiotherapy as adjuvant treatment. Methods: Two groups were evaluated: 16 post-mastectomy women with lymphedema of the upper limb and 14 post-mastectomy women without lymphedema. Patients were submitted to analysis made by software, one for posture and the other to measure ranges of movement of the shoulder, elbow, and wrists. The results obtained were compared between the right and left sides, and operated and non-operated sides, and then were submitted to statistical tests. Results: Both groups presented with anteriorization of the trunk. The women with lymphedema had head rotation to the right, protrusion of the left shoulder, and trunk inclination angle smaller on the operated side, besides bilateral elevation of the scapula when compared to the group with no lymphedema. Changes in range of motion were also smaller on the operated side in terms of flexion, abduction, and external rotation of the shoulder for all women, and for those with lymphedema, elbow extension and wrist flexion had a smaller range of motion. Conclusion: Women submitted to mastectomy presented with asymmetries and modifications in posture, and lymphedema seemed to worsen this condition. Additionally, they had deficits in range of motion in the shoulders on the operated side. Women with lymphedema also showed deficits in the elbows and wrist. PMID:24488379
Improved head-controlled TV system produces high-quality remote image
NASA Technical Reports Server (NTRS)
Goertz, R.; Lindberg, J.; Mingesz, D.; Potts, C.
1967-01-01
Manipulator operator uses an improved resolution tv camera/monitor positioning system to view the remote handling and processing of reactive, flammable, explosive, or contaminated materials. The pan and tilt motions of the camera and monitor are slaved to follow the corresponding motions of the operators head.
Effectiveness of Interaural Delays Alone as Cues During Dynamic Sound Localization
NASA Technical Reports Server (NTRS)
Wenzel, Elizabeth M.; Null, Cynthia H. (Technical Monitor)
1996-01-01
The contribution of interaural time differences (ITDs) to the localization of virtual sound sources with and without head motion was examined. Listeners estimated the apparent azimuth, elevation and distance of virtual sources presented over headphones. Stimuli (3 sec., white noise) were synthesized from minimum-phase representations of nonindividualized head-related transfer functions (HRTFs); binaural magnitude spectra were derived from the minimum phase estimates and ITDs were represented as a pure delay. During dynamic conditions, listeners were encouraged to move their heads; head position was tracked and stimuli were synthesized in real time using a Convolvotron to simulate a stationary external sound source. Two synthesis conditions were tested: (1) both interaural level differences (ILDs) and ITDs correctly correlated with source location and head motion, (2) ITDs correct, no ILDs (flat magnitude spectrum). Head movements reduced azimuth confusions primarily when interaural cues were correctly correlated, although a smaller effect was also seen for ITDs alone. Externalization was generally poor for ITD-only conditions and was enhanced by head motion only for normal HRTFs. Overall the data suggest that, while ITDs alone can provide a significant cue for azimuth, the errors most commonly associated with virtual sources are reduced by location-dependent magnitude cues.
Anthropometry: Basic Studies ad Applications. Volume 1. 1964-1975
1977-09-01
Human factors engineering. Cadavers, Moments of inertia, Mass, Aerospace medicine, Tables(Data), Responses IDENTIFIERS: DOT/5A, NTlSDOTHTS PB-241...muscles; head/neck response to low-level acceleration, voluntary isometric muscle force in the lateral direction; and three-dimensional range of motion...Prices: PC$7.50/MFS2.25 \\ 77 22 Whole Body Response Research Program Michigan Univ., Ann Arbor. Dept* of Biomechanics.*General Motors
Walk This Way: Approaching Bodies Can Influence the Processing of Faces
ERIC Educational Resources Information Center
Pilz, Karin S.; Vuong, Quoc C.; Bulthoff, Heinrich H.; Thornton, Ian M.
2011-01-01
A highly familiar type of movement occurs whenever a person walks towards you. In the present study, we investigated whether this type of motion has an effect on face processing. We took a range of different 3D head models and placed them on a single, identical 3D body model. The resulting figures were animated to approach the observer. In a first…
Altered motor control patterns in whiplash and chronic neck pain.
Woodhouse, Astrid; Vasseljen, Ottar
2008-06-20
Persistent whiplash associated disorders (WAD) have been associated with alterations in kinesthetic sense and motor control. The evidence is however inconclusive, particularly for differences between WAD patients and patients with chronic non-traumatic neck pain. The aim of this study was to investigate motor control deficits in WAD compared to chronic non-traumatic neck pain and healthy controls in relation to cervical range of motion (ROM), conjunct motion, joint position error and ROM-variability. Participants (n = 173) were recruited to three groups: 59 patients with persistent WAD, 57 patients with chronic non-traumatic neck pain and 57 asymptomatic volunteers. A 3D motion tracking system (Fastrak) was used to record maximal range of motion in the three cardinal planes of the cervical spine (sagittal, frontal and horizontal), and concurrent motion in the two associated cardinal planes relative to each primary plane were used to express conjunct motion. Joint position error was registered as the difference in head positions before and after cervical rotations. Reduced conjunct motion was found for WAD and chronic neck pain patients compared to asymptomatic subjects. This was most evident during cervical rotation. Reduced conjunct motion was not explained by current pain or by range of motion in the primary plane. Total conjunct motion during primary rotation was 13.9 degrees (95% CI; 12.2-15.6) for the WAD group, 17.9 degrees (95% CI; 16.1-19.6) for the chronic neck pain group and 25.9 degrees (95% CI; 23.7-28.1) for the asymptomatic group. As expected, maximal cervical range of motion was significantly reduced among the WAD patients compared to both control groups. No group differences were found in maximal ROM-variability or joint position error. Altered movement patterns in the cervical spine were found for both pain groups, indicating changes in motor control strategies. The changes were not related to a history of neck trauma, nor to current pain, but more likely due to long-lasting pain. No group differences were found for kinaesthetic sense.
Altered motor control patterns in whiplash and chronic neck pain
Woodhouse, Astrid; Vasseljen, Ottar
2008-01-01
Background Persistent whiplash associated disorders (WAD) have been associated with alterations in kinesthetic sense and motor control. The evidence is however inconclusive, particularly for differences between WAD patients and patients with chronic non-traumatic neck pain. The aim of this study was to investigate motor control deficits in WAD compared to chronic non-traumatic neck pain and healthy controls in relation to cervical range of motion (ROM), conjunct motion, joint position error and ROM-variability. Methods Participants (n = 173) were recruited to three groups: 59 patients with persistent WAD, 57 patients with chronic non-traumatic neck pain and 57 asymptomatic volunteers. A 3D motion tracking system (Fastrak) was used to record maximal range of motion in the three cardinal planes of the cervical spine (sagittal, frontal and horizontal), and concurrent motion in the two associated cardinal planes relative to each primary plane were used to express conjunct motion. Joint position error was registered as the difference in head positions before and after cervical rotations. Results Reduced conjunct motion was found for WAD and chronic neck pain patients compared to asymptomatic subjects. This was most evident during cervical rotation. Reduced conjunct motion was not explained by current pain or by range of motion in the primary plane. Total conjunct motion during primary rotation was 13.9° (95% CI; 12.2–15.6) for the WAD group, 17.9° (95% CI; 16.1–19.6) for the chronic neck pain group and 25.9° (95% CI; 23.7–28.1) for the asymptomatic group. As expected, maximal cervical range of motion was significantly reduced among the WAD patients compared to both control groups. No group differences were found in maximal ROM-variability or joint position error. Conclusion Altered movement patterns in the cervical spine were found for both pain groups, indicating changes in motor control strategies. The changes were not related to a history of neck trauma, nor to current pain, but more likely due to long-lasting pain. No group differences were found for kinaesthetic sense. PMID:18570647
Motion compensation for fully 4D PET reconstruction using PET superset data
NASA Astrophysics Data System (ADS)
Verhaeghe, J.; Gravel, P.; Mio, R.; Fukasawa, R.; Rosa-Neto, P.; Soucy, J.-P.; Thompson, C. J.; Reader, A. J.
2010-07-01
Fully 4D PET image reconstruction is receiving increasing research interest due to its ability to significantly reduce spatiotemporal noise in dynamic PET imaging. However, thus far in the literature, the important issue of correcting for subject head motion has not been considered. Specifically, as a direct consequence of using temporally extensive basis functions, a single instance of movement propagates to impair the reconstruction of multiple time frames, even if no further movement occurs in those frames. Existing 3D motion compensation strategies have not yet been adapted to 4D reconstruction, and as such the benefits of 4D algorithms have not yet been reaped in a clinical setting where head movement undoubtedly occurs. This work addresses this need, developing a motion compensation method suitable for fully 4D reconstruction methods which exploits an optical tracking system to measure the head motion along with PET superset data to store the motion compensated data. List-mode events are histogrammed as PET superset data according to the measured motion, and a specially devised normalization scheme for motion compensated reconstruction from the superset data is required. This work proceeds to propose the corresponding time-dependent normalization modifications which are required for a major class of fully 4D image reconstruction algorithms (those which use linear combinations of temporal basis functions). Using realistically simulated as well as real high-resolution PET data from the HRRT, we demonstrate both the detrimental impact of subject head motion in fully 4D PET reconstruction and the efficacy of our proposed modifications to 4D algorithms. Benefits are shown both for the individual PET image frames as well as for parametric images of tracer uptake and volume of distribution for 18F-FDG obtained from Patlak analysis.
Motion compensation for fully 4D PET reconstruction using PET superset data.
Verhaeghe, J; Gravel, P; Mio, R; Fukasawa, R; Rosa-Neto, P; Soucy, J-P; Thompson, C J; Reader, A J
2010-07-21
Fully 4D PET image reconstruction is receiving increasing research interest due to its ability to significantly reduce spatiotemporal noise in dynamic PET imaging. However, thus far in the literature, the important issue of correcting for subject head motion has not been considered. Specifically, as a direct consequence of using temporally extensive basis functions, a single instance of movement propagates to impair the reconstruction of multiple time frames, even if no further movement occurs in those frames. Existing 3D motion compensation strategies have not yet been adapted to 4D reconstruction, and as such the benefits of 4D algorithms have not yet been reaped in a clinical setting where head movement undoubtedly occurs. This work addresses this need, developing a motion compensation method suitable for fully 4D reconstruction methods which exploits an optical tracking system to measure the head motion along with PET superset data to store the motion compensated data. List-mode events are histogrammed as PET superset data according to the measured motion, and a specially devised normalization scheme for motion compensated reconstruction from the superset data is required. This work proceeds to propose the corresponding time-dependent normalization modifications which are required for a major class of fully 4D image reconstruction algorithms (those which use linear combinations of temporal basis functions). Using realistically simulated as well as real high-resolution PET data from the HRRT, we demonstrate both the detrimental impact of subject head motion in fully 4D PET reconstruction and the efficacy of our proposed modifications to 4D algorithms. Benefits are shown both for the individual PET image frames as well as for parametric images of tracer uptake and volume of distribution for (18)F-FDG obtained from Patlak analysis.
Interaction of the body, head, and eyes during walking and turning
NASA Technical Reports Server (NTRS)
Imai, T.; Moore, S. T.; Raphan, T.; Cohen, B.
2001-01-01
Body, head, and eye movements were measured in five subjects during straight walking and while turning corners. The purpose was to determine how well the head and eyes followed the linear trajectory of the body in space and whether head orientation followed changes in the gravito-inertial acceleration vector (GIA). Head and body movements were measured with a video-based motion analysis system and horizontal, vertical, and torsional eye movements with video-oculography. During straight walking, there was lateral body motion at the stride frequency, which was at half the frequency of stepping. The GIA oscillated about the direction of heading, according to the acceleration and deceleration associated with heel strike and toe flexion, and the body yawed in concert with stepping. Despite the linear and rotatory motions of the head and body, the head pointed along the forward motion of the body during straight walking. The head pitch/roll component appeared to compensate for vertical and horizontal acceleration of the head rather than orienting to the tilt of the GIA or anticipating it. When turning corners, subjects walked on a 50-cm radius over two steps or on a 200-cm radius in five to seven steps. Maximum centripetal accelerations in sharp turns were ca.0.4 g, which tilted the GIA ca.21 degrees with regard to the heading. This was anticipated by a roll tilt of the head of up to 8 degrees. The eyes rolled 1-1.5 degrees and moved down into the direction of linear acceleration during the tilts of the GIA. Yaw head deviations moved smoothly through the turn, anticipating the shift in lateral body trajectory by as much as 25 degrees. The trunk did not anticipate the change in trajectory. Thus, in contrast to straight walking, the tilt axes of the head and the GIA tended to align during turns. Gaze was stable in space during the slow phases and jumped forward in saccades along the trajectory, leading it by larger angles when the angular velocity of turning was greater. The anticipatory roll head movements during turning are likely to be utilized to overcome inertial forces that would destabilize balance during turning. The data show that compensatory eye, head, and body movements stabilize gaze during straight walking, while orienting mechanisms direct the eyes, head, and body to tilts of the GIA in space during turning.
Effect of head motion on MRI B0 field distribution.
Liu, Jiaen; de Zwart, Jacco A; van Gelderen, Peter; Murphy-Boesch, Joseph; Duyn, Jeff H
2018-05-16
To identify and characterize the sources of B 0 field changes due to head motion, to reduce motion sensitivity in human brain MRI. B 0 fields were measured in 5 healthy human volunteers at various head poses. After measurement of the total field, the field originating from the subject was calculated by subtracting the external field generated by the magnet and shims. A subject-specific susceptibility model was created to quantify the contribution of the head and torso. The spatial complexity of the field changes was analyzed using spherical harmonic expansion. Minor head pose changes can cause substantial and spatially complex field changes in the brain. For rotations and translations of approximately 5 º and 5 mm, respectively, at 7 T, the field change that is associated with the subject's magnetization generates a standard deviation (SD) of about 10 Hz over the brain. The stationary torso contributes to this subject-associated field change significantly with a SD of about 5 Hz. The subject-associated change leads to image-corrupting phase errors in multi-shot T2*-weighted acquisitions. The B 0 field changes arising from head motion are problematic for multishot T2*-weighted imaging. Characterization of the underlying sources provides new insights into mitigation strategies, which may benefit from individualized predictive field models in addition to real-time field monitoring and correction strategies. © 2018 International Society for Magnetic Resonance in Medicine.
Saunders, Jeffrey A.
2014-01-01
Direction of self-motion during walking is indicated by multiple cues, including optic flow, nonvisual sensory cues, and motor prediction. I measured the reliability of perceived heading from visual and nonvisual cues during walking, and whether cues are weighted in an optimal manner. I used a heading alignment task to measure perceived heading during walking. Observers walked toward a target in a virtual environment with and without global optic flow. The target was simulated to be infinitely far away, so that it did not provide direct feedback about direction of self-motion. Variability in heading direction was low even without optic flow, with average RMS error of 2.4°. Global optic flow reduced variability to 1.9°–2.1°, depending on the structure of the environment. The small amount of variance reduction was consistent with optimal use of visual information. The relative contribution of visual and nonvisual information was also measured using cue conflict conditions. Optic flow specified a conflicting heading direction (±5°), and bias in walking direction was used to infer relative weighting. Visual feedback influenced heading direction by 16%–34% depending on scene structure, with more effect with dense motion parallax. The weighting of visual feedback was close to the predictions of an optimal integration model given the observed variability measures. PMID:24648194
Real-time motion analytics during brain MRI improve data quality and reduce costs.
Dosenbach, Nico U F; Koller, Jonathan M; Earl, Eric A; Miranda-Dominguez, Oscar; Klein, Rachel L; Van, Andrew N; Snyder, Abraham Z; Nagel, Bonnie J; Nigg, Joel T; Nguyen, Annie L; Wesevich, Victoria; Greene, Deanna J; Fair, Damien A
2017-11-01
Head motion systematically distorts clinical and research MRI data. Motion artifacts have biased findings from many structural and functional brain MRI studies. An effective way to remove motion artifacts is to exclude MRI data frames affected by head motion. However, such post-hoc frame censoring can lead to data loss rates of 50% or more in our pediatric patient cohorts. Hence, many scanner operators collect additional 'buffer data', an expensive practice that, by itself, does not guarantee sufficient high-quality MRI data for a given participant. Therefore, we developed an easy-to-setup, easy-to-use Framewise Integrated Real-time MRI Monitoring (FIRMM) software suite that provides scanner operators with head motion analytics in real-time, allowing them to scan each subject until the desired amount of low-movement data has been collected. Our analyses show that using FIRMM to identify the ideal scan time for each person can reduce total brain MRI scan times and associated costs by 50% or more. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vicsek, Tamas
1997-03-01
It is demonstrated that a wide range of experimental results on biological motion can be successfully interpreted in terms of statistical physics motivated models taking into account the relevant microscopic details of motor proteins and allowing analytic solutions. Two important examples are considered, i) the motion of a single kinesin molecule along microtubules inside individual cells and ii) muscle contraction which is a macroscopic phenomenon due to the collective action of a large number of myosin heads along actin filaments. i) Recently individual two-headed kinesin molecules have been studied in in vitro motility assays revealing a number of their peculiar transport properties. Here we propose a simple and robust model for the kinesin stepping process with elastically coupled Brownian heads showing all of these properties. The analytic treatment of our model results in a very good fit to the experimental data and practically has no free parameters. ii) Myosin is an ATPase enzyme that converts the chemical energy stored in ATP molecules into mechanical work. During muscle contraction, the myosin cross-bridges attach to the actin filaments and exert force on them yielding a relative sliding of the actin and myosin filaments. In this paper we present a simple mechanochemical model for the cross-bridge interaction involving the relevant kinetic data and providing simple analytic solutions for the mechanical properties of muscle contraction, such as the force-velocity relationship or the relative number of the attached cross-bridges. So far the only analytic formula which could be fitted to the measured force-velocity curves has been the well known Hill equation containing parameters lacking clear microscopic origin. The main advantages of our new approach are that it explicitly connects the mechanical data with the kinetic data and the concentration of the ATP and ATPase products and as such it leads to new analytic solutions which agree extremely well with a wide range of experimental curves, while the parameters of the corresponding expressions have well defined microscopic meaning.
Modulation of high-frequency vestibuloocular reflex during visual tracking in humans
NASA Technical Reports Server (NTRS)
Das, V. E.; Leigh, R. J.; Thomas, C. W.; Averbuch-Heller, L.; Zivotofsky, A. Z.; Discenna, A. O.; Dell'Osso, L. F.
1995-01-01
1. Humans may visually track a moving object either when they are stationary or in motion. To investigate visual-vestibular interaction during both conditions, we compared horizontal smooth pursuit (SP) and active combined eye-head tracking (CEHT) of a target moving sinusoidally at 0.4 Hz in four normal subjects while the subjects were either stationary or vibrated in yaw at 2.8 Hz. We also measured the visually enhanced vestibuloocular reflex (VVOR) during vibration in yaw at 2.8 Hz over a peak head velocity range of 5-40 degrees/s. 2. We found that the gain of the VVOR at 2.8 Hz increased in all four subjects as peak head velocity increased (P < 0.001), with minimal phase changes, such that mean retinal image slip was held below 5 degrees/s. However, no corresponding modulation in vestibuloocular reflex gain occurred with increasing peak head velocity during a control condition when subjects were rotated in darkness. 3. During both horizontal SP and CEHT, tracking gains were similar, and the mean slip speed of the target's image on the retina was held below 5.5 degrees/s whether subjects were stationary or being vibrated at 2.8 Hz. During both horizontal SP and CEHT of target motion at 0.4 Hz, while subjects were vibrated in yaw, VVOR gain for the 2.8-Hz head rotations was similar to or higher than that achieved during fixation of a stationary target. This is in contrast to the decrease of VVOR gain that is reported while stationary subjects perform CEHT.(ABSTRACT TRUNCATED AT 250 WORDS).
NASA Technical Reports Server (NTRS)
Arthur, Jarvis J., III; Prinzel, Lawrence J., III; Barnes, James R.; Williams, Steven P.; Jones, Denise R.; Harrison, Stephanie J.; Bailey, Randall E.
2014-01-01
Research, development, test, and evaluation of flight deck interface technologies is being conducted by NASA to proactively identify, develop, and mature tools, methods, and technologies for improving overall aircraft safety of new and legacy vehicles operating in Next Generation Air Transportation System (NextGen). Under the Vehicle Systems Safety Technologies (VSST) project in the Aviation Safety Program, one specific area of research is the use of small Head-Worn Displays (HWDs) as an equivalent display to a Head-Up Display (HUD). Title 14 of the US Code of Federal Regulations (CFR) 91.175 describes a possible operational credit which can be obtained with airplane equipage of a HUD or an "equivalent" display combined with Enhanced Vision (EV). If successful, a HWD may provide the same safety and operational benefits as current HUD-equipped aircraft but for significantly more aircraft in which HUD installation is neither practical nor possible. A simulation experiment was conducted to evaluate if the HWD, coupled with a head-tracker, can provide an equivalent display to a HUD. Comparative testing was performed in the Research Flight Deck (RFD) Cockpit Motion Facility (CMF) full mission, motion-based simulator at NASA Langley. Twelve airline crews conducted approach and landing, taxi, and departure operations during low visibility operations (1000' Runway Visual Range (RVR), 300' RVR) at Memphis International Airport (Federal Aviation Administration (FAA) identifier: KMEM). The results showed that there were no statistical differences in the crews performance in terms of touchdown and takeoff. Further, there were no statistical differences between the HUD and HWD in pilots' responses to questionnaires.
Indovina, Iole; Maffei, Vincenzo; Pauwels, Karl; Macaluso, Emiliano; Orban, Guy A; Lacquaniti, Francesco
2013-05-01
Multiple visual signals are relevant to perception of heading direction. While the role of optic flow and depth cues has been studied extensively, little is known about the visual effects of gravity on heading perception. We used fMRI to investigate the contribution of gravity-related visual cues on the processing of vertical versus horizontal apparent self-motion. Participants experienced virtual roller-coaster rides in different scenarios, at constant speed or 1g-acceleration/deceleration. Imaging results showed that vertical self-motion coherent with gravity engaged the posterior insula and other brain regions that have been previously associated with vertical object motion under gravity. This selective pattern of activation was also found in a second experiment that included rectilinear motion in tunnels, whose direction was cued by the preceding open-air curves only. We argue that the posterior insula might perform high-order computations on visual motion patterns, combining different sensory cues and prior information about the effects of gravity. Medial-temporal regions including para-hippocampus and hippocampus were more activated by horizontal motion, preferably at constant speed, consistent with a role in inertial navigation. Overall, the results suggest partially distinct neural representations of the cardinal axes of self-motion (horizontal and vertical). Copyright © 2013 Elsevier Inc. All rights reserved.
Drift Reduction in Pedestrian Navigation System by Exploiting Motion Constraints and Magnetic Field.
Ilyas, Muhammad; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok
2016-09-09
Pedestrian navigation systems (PNS) using foot-mounted MEMS inertial sensors use zero-velocity updates (ZUPTs) to reduce drift in navigation solutions and estimate inertial sensor errors. However, it is well known that ZUPTs cannot reduce all errors, especially as heading error is not observable. Hence, the position estimates tend to drift and even cyclic ZUPTs are applied in updated steps of the Extended Kalman Filter (EKF). This urges the use of other motion constraints for pedestrian gait and any other valuable heading reduction information that is available. In this paper, we exploit two more motion constraints scenarios of pedestrian gait: (1) walking along straight paths; (2) standing still for a long time. It is observed that these motion constraints (called "virtual sensor"), though considerably reducing drift in PNS, still need an absolute heading reference. One common absolute heading estimation sensor is the magnetometer, which senses the Earth's magnetic field and, hence, the true heading angle can be calculated. However, magnetometers are susceptible to magnetic distortions, especially in indoor environments. In this work, an algorithm, called magnetic anomaly detection (MAD) and compensation is designed by incorporating only healthy magnetometer data in the EKF updating step, to reduce drift in zero-velocity updated INS. Experiments are conducted in GPS-denied and magnetically distorted environments to validate the proposed algorithms.
Simulated pain and cervical motion in patients with chronic disorders of the cervical spine.
Dvir, Zeevi; Gal-Eshel, Noga; Shamir, Boaz; Pevzner, Evgeny; Peretz, Chava; Knoller, Nachshon
2004-01-01
The primary objective of the present study was to determine how simulated severe cervical pain affects cervical motion in patients suffering from two distinct chronic cervical disorders: whiplash (n=25) and degenerative changes (n=25). The second objective was to derive an index that would allow the differentiation of maximal from submaximal performances of cervical range of motion. Patients first performed maximal movement of the head (maximal effort) in each of the six primary directions and then repeated the test as if they were suffering from a much more intense level of pain (submaximal effort). All measurements were repeated within four to seven days. In both groups, there was significant compression of cervical motion during the submaximal effort. This compression was also highly stable on a test-retest basis. In both groups, a significantly higher average coefficient of variation was associated with the imagined pain and it was significantly different between the two clinical groups. In the whiplash group, a logistic regression model allowed the derivation of coefficient of variation-based cutoff scores that might, at selected levels of probability and an individual level, identify chronic whiplash patients who intentionally magnify their motion restriction using pain as a cue. However, the relatively small and very stable compression of cervical motion under pain simulation supports the view that the likelihood that chronic whiplash patients are magnifying their restriction of cervical range of motion using pain as a cue is very low.
Automatic EEG-assisted retrospective motion correction for fMRI (aE-REMCOR).
Wong, Chung-Ki; Zotev, Vadim; Misaki, Masaya; Phillips, Raquel; Luo, Qingfei; Bodurka, Jerzy
2016-04-01
Head motions during functional magnetic resonance imaging (fMRI) impair fMRI data quality and introduce systematic artifacts that can affect interpretation of fMRI results. Electroencephalography (EEG) recordings performed simultaneously with fMRI provide high-temporal-resolution information about ongoing brain activity as well as head movements. Recently, an EEG-assisted retrospective motion correction (E-REMCOR) method was introduced. E-REMCOR utilizes EEG motion artifacts to correct the effects of head movements in simultaneously acquired fMRI data on a slice-by-slice basis. While E-REMCOR is an efficient motion correction approach, it involves an independent component analysis (ICA) of the EEG data and identification of motion-related ICs. Here we report an automated implementation of E-REMCOR, referred to as aE-REMCOR, which we developed to facilitate the application of E-REMCOR in large-scale EEG-fMRI studies. The aE-REMCOR algorithm, implemented in MATLAB, enables an automated preprocessing of the EEG data, an ICA decomposition, and, importantly, an automatic identification of motion-related ICs. aE-REMCOR has been used to perform retrospective motion correction for 305 fMRI datasets from 16 subjects, who participated in EEG-fMRI experiments conducted on a 3T MRI scanner. Performance of aE-REMCOR has been evaluated based on improvement in temporal signal-to-noise ratio (TSNR) of the fMRI data, as well as correction efficiency defined in terms of spike reduction in fMRI motion parameters. The results show that aE-REMCOR is capable of substantially reducing head motion artifacts in fMRI data. In particular, when there are significant rapid head movements during the scan, a large TSNR improvement and high correction efficiency can be achieved. Depending on a subject's motion, an average TSNR improvement over the brain upon the application of aE-REMCOR can be as high as 27%, with top ten percent of the TSNR improvement values exceeding 55%. The average correction efficiency over the 305 fMRI scans is 18% and the largest achieved efficiency is 71%. The utility of aE-REMCOR on the resting state fMRI connectivity of the default mode network is also examined. The motion-induced position-dependent error in the DMN connectivity analysis is shown to be reduced when aE-REMCOR is utilized. These results demonstrate that aE-REMCOR can be conveniently and efficiently used to improve fMRI motion correction in large clinical EEG-fMRI studies. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Apparatus and Method for Assessing Vestibulo-Ocular Function
NASA Technical Reports Server (NTRS)
Shelhamer, Mark J. (Inventor)
2015-01-01
A system for assessing vestibulo-ocular function includes a motion sensor system adapted to be coupled to a user's head; a data processing system configured to communicate with the motion sensor system to receive the head-motion signals; a visual display system configured to communicate with the data processing system to receive image signals from the data processing system; and a gain control device arranged to be operated by the user and to communicate gain adjustment signals to the data processing system.
Pretto, Paolo; Oberfeld, Daniel; Hecht, Heiko; Bülthoff, Heinrich H.
2017-01-01
This study investigated the role of vection (i.e., a visually induced sense of self-motion), optokinetic nystagmus (OKN), and inadvertent head movements in visually induced motion sickness (VIMS), evoked by yaw rotation of the visual surround. These three elements have all been proposed as contributing factors in VIMS, as they can be linked to different motion sickness theories. However, a full understanding of the role of each factor is still lacking because independent manipulation has proven difficult in the past. We adopted an integrative approach to the problem by obtaining measures of potentially relevant parameters in four experimental conditions and subsequently combining them in a linear mixed regression model. To that end, participants were exposed to visual yaw rotation in four separate sessions. Using a full factorial design, the OKN was manipulated by a fixation target (present/absent), and vection strength by introducing a conflict in the motion direction of the central and peripheral field of view (present/absent). In all conditions, head movements were minimized as much as possible. Measured parameters included vection strength, vection variability, OKN slow phase velocity, OKN frequency, the number of inadvertent head movements, and inadvertent head tilt. Results show that VIMS increases with vection strength, but that this relation varies among participants (R2 = 0.48). Regression parameters for vection variability, head and eye movement parameters were not significant. These results may seem to be in line with the Sensory Conflict theory on motion sickness, but we argue that a more detailed definition of the exact nature of the conflict is required to fully appreciate the relationship between vection and VIMS. PMID:28380077
Anderst, William J.; West, Tyler; Donaldson, William F; Lee, Joon Y.; Kang, James D.
2016-01-01
Study Design A longitudinal study using biplane radiography to measure in vivo intervertebral range of motion (ROM) during dynamic flexion/extension and rotation. Objective To longitudinally compare intervertebral maximal ROM and midrange motion in asymptomatic control subjects and single-level arthrodesis patients. Summary of Background Data In vitro studies consistently report that adjacent segment maximal ROM increases superior and inferior to cervical arthrodesis. Previous in vivo results have been conflicting, indicating that maximal ROM may or may not increase superior and/or inferior to the arthrodesis. There are no previous reports of midrange motion in arthrodesis patients and similar-aged controls. Methods Eight single-level (C5/C6) anterior arthrodesis patients (tested 7±1 months and 28±6 months post-surgery) and six asymptomatic control subjects (tested twice, 58±6 months apart) performed dynamic full ROM flexion/extension and axial rotation while biplane radiographs were collected at 30 images/s. A previously validated tracking process determined three-dimensional vertebral position from each pair of radiographs with sub-millimeter accuracy. The intervertebral maximal ROM and midrange motion in flexion/extension, rotation, lateral bending, and anterior-posterior translation were compared between test dates and between groups. Results Adjacent segment maximal ROM did not increase over time during flexion/extension or rotation movements. Adjacent segment maximal rotational ROM was not significantly greater in arthrodesis patients than in corresponding motion segments of similar-aged controls. C4/C5 adjacent segment rotation during the midrange of head motion and maximal anterior-posterior translation were significantly greater in arthrodesis patients than in the corresponding motion segment in controls on the second test date. Conclusions C5/C6 arthrodesis appears to significantly affect midrange, but not end-range, adjacent segment motions. The effects of arthrodesis on adjacent segment motion may be best evaluated by longitudinal studies that compare maximal and midrange adjacent segment motion to corresponding motion segments of similar-aged controls to determine if the adjacent segment motion is truly excessive. PMID:27831986
Anderst, William J; West, Tyler; Donaldson, William F; Lee, Joon Y; Kang, James D
2016-11-15
A longitudinal study using biplane radiography to measure in vivo intervertebral range of motion (ROM) during dynamic flexion/extension, and rotation. To longitudinally compare intervertebral maximal ROM and midrange motion in asymptomatic control subjects and single-level arthrodesis patients. In vitro studies consistently report that adjacent segment maximal ROM increases superior and inferior to cervical arthrodesis. Previous in vivo results have been conflicting, indicating that maximal ROM may or may not increase superior and/or inferior to the arthrodesis. There are no previous reports of midrange motion in arthrodesis patients and similar-aged controls. Eight single-level (C5/C6) anterior arthrodesis patients (tested 7 ± 1 months and 28 ± 6 months postsurgery) and six asymptomatic control subjects (tested twice, 58 ± 6 months apart) performed dynamic full ROM flexion/extension and axial rotation whereas biplane radiographs were collected at 30 images per second. A previously validated tracking process determined three-dimensional vertebral position from each pair of radiographs with submillimeter accuracy. The intervertebral maximal ROM and midrange motion in flexion/extension, rotation, lateral bending, and anterior-posterior translation were compared between test dates and between groups. Adjacent segment maximal ROM did not increase over time during flexion/extension, or rotation movements. Adjacent segment maximal rotational ROM was not significantly greater in arthrodesis patients than in corresponding motion segments of similar-aged controls. C4/C5 adjacent segment rotation during the midrange of head motion and maximal anterior-posterior translation were significantly greater in arthrodesis patients than in the corresponding motion segment in controls on the second test date. C5/C6 arthrodesis appears to significantly affect midrange, but not end-range, adjacent segment motions. The effects of arthrodesis on adjacent segment motion may be best evaluated by longitudinal studies that compare maximal and midrange adjacent segment motion to corresponding motion segments of similar-aged controls to determine if the adjacent segment motion is truly excessive. 3.
Clinical effectiveness of a Pilates treatment for forward head posture
Lee, Sun-Myung; Lee, Chang-Hyung; O’Sullivan, David; Jung, Joo-Ha; Park, Jung-Jun
2016-01-01
[Purpose] This study compared the effects of pilates and an exercise program on the craniovertebral angle, cervical range of motion, pain, and muscle fatigue in subjects with a forward head posture (FHP). [Subjects and Methods] A total of 28 sedentary females (age 20 to 39 years) with FHP were randomly assigned to pilates (n=14) and combined (n=14) exercise groups. The study was a randomized, controlled, double-blind study with the two groups performing exercise 50 min/day, 3 days/week, with an intensity of 11–15 rating of perceived exertion (RPE) for ten weeks. The main outcome measures were craniovertebral angle, cervical range of motion (ROM), pain levels assessed by visual analog scale (VAS), and neck disability index (NDI). Surface electromyography was also used to measure muscle fatigue. [Results] There were significant increases in craniovertebral angle and cervical ROM in the pilates group, but none in the control group. The only significant differences in muscle activity were recorded in the sternocleidomastoid muscle in the pilates group. Both exercise programs had positive effects on pain measures, as VAS and NDI were significantly decreased. [Conclusion] The results suggest that pilates could be recommended as an appropriate exercise for treatment of FHP in sedentary individuals. PMID:27512253
Clinical effectiveness of a Pilates treatment for forward head posture.
Lee, Sun-Myung; Lee, Chang-Hyung; O'Sullivan, David; Jung, Joo-Ha; Park, Jung-Jun
2016-07-01
[Purpose] This study compared the effects of pilates and an exercise program on the craniovertebral angle, cervical range of motion, pain, and muscle fatigue in subjects with a forward head posture (FHP). [Subjects and Methods] A total of 28 sedentary females (age 20 to 39 years) with FHP were randomly assigned to pilates (n=14) and combined (n=14) exercise groups. The study was a randomized, controlled, double-blind study with the two groups performing exercise 50 min/day, 3 days/week, with an intensity of 11-15 rating of perceived exertion (RPE) for ten weeks. The main outcome measures were craniovertebral angle, cervical range of motion (ROM), pain levels assessed by visual analog scale (VAS), and neck disability index (NDI). Surface electromyography was also used to measure muscle fatigue. [Results] There were significant increases in craniovertebral angle and cervical ROM in the pilates group, but none in the control group. The only significant differences in muscle activity were recorded in the sternocleidomastoid muscle in the pilates group. Both exercise programs had positive effects on pain measures, as VAS and NDI were significantly decreased. [Conclusion] The results suggest that pilates could be recommended as an appropriate exercise for treatment of FHP in sedentary individuals.
Coordinated three-dimensional motion of the head and torso by dynamic neural networks.
Kim, J; Hemami, H
1998-01-01
The problem of trajectory tracking control of a three dimensional (3D) model of the human upper torso and head is considered. The torso and the head are modeled as two rigid bodies connected at one point, and the Newton-Euler method is used to derive the nonlinear differential equations that govern the motion of the system. The two-link system is driven by six pairs of muscle like actuators that possess physiologically inspired alpha like and gamma like inputs, and spindle like and Golgi tendon organ like outputs. These outputs are utilized as reflex feedback for stability and stiffness control, in a long loop feedback for the purpose of estimating the state of the system (somesthesis), and as part of the input to the controller. Ideal delays of different duration are included in the feedforward and feedback paths of the system to emulate such delays encountered in physiological systems. Dynamical neural networks are trained to learn effective control of the desired maneuvers of the system. The feasibility of the controller is demonstrated by computer simulation of the successful execution of the desired maneuvers. This work demonstrates the capabilities of neural circuits in controlling highly nonlinear systems with multidelays in their feedforward and feedback paths. The ultimate long range goal of this research is toward understanding the working of the central nervous system in controlling movement. It is an interdisciplinary effort relying on mechanics, biomechanics, neuroscience, system theory, physiology and anatomy, and its short range relevance to rehabilitation must be noted.
NASA Technical Reports Server (NTRS)
Stone, Leland S.; Perrone, J. A.
1997-01-01
We previously developed a template model of primate visual self-motion processing that proposes a specific set of projections from MT-like local motion sensors onto output units to estimate heading and relative depth from optic flow. At the time, we showed that that the model output units have emergent properties similar to those of MSTd neurons, although there was little physiological evidence to test the model more directly. We have now systematically examined the properties of the model using stimulus paradigms used by others in recent single-unit studies of MST: 1) 2-D bell-shaped heading tuning. Most MSTd neurons and model output units show bell-shaped heading tuning. Furthermore, we found that most model output units and the finely-sampled example neuron in the Duffy-Wurtz study are well fit by a 2D gaussian (sigma approx. 35deg, r approx. 0.9). The bandwidth of model and real units can explain why Lappe et al. found apparent sigmoidal tuning using a restricted range of stimuli (+/-40deg). 2) Spiral Tuning and Invariance. Graziano et al. found that many MST neurons appear tuned to a specific combination of rotation and expansion (spiral flow) and that this tuning changes little for approx. 10deg shifts in stimulus placement. Simulations of model output units under the same conditions quantitatively replicate this result. We conclude that a template architecture may underlie MT inputs to MST.
A study of emergency American football helmet removal techniques.
Swartz, Erik E; Mihalik, Jason P; Decoster, Laura C; Hernandez, Adam E
2012-09-01
The purpose was to compare head kinematics between the Eject Helmet Removal System and manual football helmet removal. This quasi-experimental study was conducted in a controlled laboratory setting. Thirty-two certified athletic trainers (sex, 19 male and 13 female; age, 33 ± 10 years; height, 175 ± 12 cm; mass, 86 ± 20 kg) removed a football helmet from a healthy model under 2 conditions: manual helmet removal and Eject system helmet removal. A 6-camera motion capture system recorded 3-dimensional head position. Our outcome measures consisted of the average angular velocity and acceleration of the head in each movement plane (sagittal, frontal, and transverse), the resultant angular velocity and acceleration, and total motion. Paired-samples t tests compared each variable across the 2 techniques. Manual helmet removal elicited greater average angular velocity in the sagittal and transverse planes and greater resultant angular velocity compared with the Eject system. No differences were observed in average angular acceleration in any single plane of movement; however, the resultant angular acceleration was greater during manual helmet removal. The Eject Helmet Removal System induced greater total head motion. Although the Eject system created more motion at the head, removing a helmet manually resulted in more sudden perturbations as identified by resultant velocity and acceleration of the head. The implications of these findings relate to the care of all cervical spine-injured patients in emergency medical settings, particularly in scenarios where helmet removal is necessary. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Perrone, John A.; Stone, Leland S.
1997-01-01
We have previously proposed a computational neural-network model by which the complex patterns of retinal image motion generated during locomotion (optic flow) can be processed by specialized detectors acting as templates for specific instances of self-motion. The detectors in this template model respond to global optic flow by sampling image motion over a large portion of the visual field through networks of local motion sensors with properties similar to neurons found in the middle temporal (MT) area of primate extrastriate visual cortex. The model detectors were designed to extract self-translation (heading), self-rotation, as well as the scene layout (relative distances) ahead of a moving observer, and are arranged in cortical-like heading maps to perform this function. Heading estimation from optic flow has been postulated by some to be implemented within the medial superior temporal (MST) area. Others have questioned whether MST neurons can fulfill this role because some of their receptive-field properties appear inconsistent with a role in heading estimation. To resolve this issue, we systematically compared MST single-unit responses with the outputs of model detectors under matched stimulus conditions. We found that the basic physiological properties of MST neurons can be explained by the template model. We conclude that MST neurons are well suited to support heading estimation and that the template model provides an explicit set of testable hypotheses which can guide future exploration of MST and adjacent areas within the primate superior temporal sulcus.
Meisingset, Ingebrigt; Stensdotter, Ann-Katrin; Woodhouse, Astrid; Vasseljen, Ottar
2016-04-01
Neck pain is associated with several alterations in neck motion and motor control, but most of the findings are based on cross-sectional studies. The aim of this study was to investigate associations between changes in neck motion and motor control, and changes in neck pain and disability in physiotherapy patients during a course of treatment. Prospective cohort study. Subjects with non-specific neck pain (n = 71) participated in this study. Neck flexibility, joint position error (JPE), head steadiness, trajectory movement control and postural sway were recorded before commencement of physiotherapy (baseline), at 2 weeks, and at 2 months. Numerical Rating Scale and Neck Disability Index were used to measure neck pain and disability at the day of testing. To analyze within subjects effects in neck motion and motor control, neck pain, and disability over time we used fixed effects linear regression analysis. Changes in neck motion and motor control occurred primarily within 2 weeks. Reduction in neck pain was associated with increased cervical range of motion in flexion-/extension and increased postural sway when standing with eyes open. Decreased neck disability was associated with some variables for neck flexibility and trajectory movement control. Cervical range of motion in flexion-/extension was the only variable associated with changes in both neck pain and neck disability. This study shows that few of the variables for neck motion and motor control were associated with changes neck pain and disability over a course of 2 months with physiotherapy treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
In vivo gliding and contact characteristics of the sigmoid notch and the ulna in forearm rotation.
Chen, Yan Rong; Tang, Jin Bo
2013-08-01
To investigate shifting of the contact center over the surfaces of 2 opposing bones of the distal radioulnar joint during forearm rotation. We recruited 8 volunteers and used their right wrists. Serial computed tomography scans were obtained with the forearm at neutral position and 6 other positions of forearm rotation. We reconstructed 3-dimensional images and mapped contact regions of both the sigmoid notch and ulnar head by calculating the shortest distance between the 2 opposing bones. The center of contact was also defined and plotted against the distal radioulnar joint rotation to determine the sliding distance over the surfaces of the 2 bones. During forearm rotation, the maximal sliding of the sigmoid notch over the ulnar head was 7.4 mm in forearm pronation and 9.2 mm in forearm supination, which occurred in volar-dorsal direction primarily. Sliding of the ulnar head over the sigmoid notch was more limited, measuring 4.7 mm during pronation and 2.3 mm during supination. Most of the motion occurred between 30° pronation and 60° supination. In the proximal-distal direction, the contact site of the sigmoid notch with the ulnar head translated distally 1.6 mm during pronation and proximally 0.7 mm during supination. During forearm rotation, the sigmoid notch slides substantially against the ulnar head at each part of the forearm rotation arc. The sliding of the ulnar head over the sigmoid notch is smaller, most of which is at the range from moderate forearm pronation to slight supination. The contact site of the sigmoid notch with the ulnar head moves slightly distally during forearm pronation and proximally during supination. The in vivo findings provide more detailed information and insight into distal radioulnar joint motion kinematics. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Head movements and postures as pain behavior
Al-Hamadi, Ayoub; Limbrecht-Ecklundt, Kerstin; Walter, Steffen; Traue, Harald C.
2018-01-01
Pain assessment can benefit from observation of pain behaviors, such as guarding or facial expression, and observational pain scales are widely used in clinical practice with nonverbal patients. However, little is known about head movements and postures in the context of pain. In this regard, we analyze videos of three publically available datasets. The BioVid dataset was recorded with healthy participants subjected to painful heat stimuli. In the BP4D dataset, healthy participants performed a cold-pressor test and several other tasks (meant to elicit emotion). The UNBC dataset videos show shoulder pain patients during range-of-motion tests to their affected and unaffected limbs. In all videos, participants were sitting in an upright position. We studied head movements and postures that occurred during the painful and control trials by measuring head orientation from video over time, followed by analyzing posture and movement summary statistics and occurrence frequencies of typical postures and movements. We found significant differences between pain and control trials with analyses of variance and binomial tests. In BioVid and BP4D, pain was accompanied by head movements and postures that tend to be oriented downwards or towards the pain site. We also found differences in movement range and speed in all three datasets. The results suggest that head movements and postures should be considered for pain assessment and research. As additional pain indicators, they possibly might improve pain management whenever behavior is assessed, especially in nonverbal individuals such as infants or patients with dementia. However, in advance more research is needed to identify specific head movements and postures in pain patients. PMID:29444153
An evaluation of 3D head pose estimation using the Microsoft Kinect v2.
Darby, John; Sánchez, María B; Butler, Penelope B; Loram, Ian D
2016-07-01
The Kinect v2 sensor supports real-time non-invasive 3D head pose estimation. Because the sensor is small, widely available and relatively cheap it has great potential as a tool for groups interested in measuring head posture. In this paper we compare the Kinect's head pose estimates with a marker-based record of ground truth in order to establish its accuracy. During movement of the head and neck alone (with static torso), we find average errors in absolute yaw, pitch and roll angles of 2.0±1.2°, 7.3±3.2° and 2.6±0.7°, and in rotations relative to the rest pose of 1.4±0.5°, 2.1±0.4° and 2.0±0.8°. Larger head rotations where it becomes difficult to see facial features can cause estimation to fail (10.2±6.1% of all poses in our static torso range of motion tests) but we found no significant changes in performance with the participant standing further away from Kinect - additionally enabling full-body pose estimation - or without performing face shape calibration, something which is not always possible for younger or disabled participants. Where facial features remain visible, the sensor has applications in the non-invasive assessment of postural control, e.g. during a programme of physical therapy. In particular, a multi-Kinect setup covering the full range of head (and body) movement would appear to be a promising way forward. Copyright © 2016 Elsevier B.V. All rights reserved.
Eye and head motion during head turns in spaceflight
NASA Technical Reports Server (NTRS)
Thornton, William E.; Uri, John J.; Moore, Thomas P.; Pool, Sam L.
1988-01-01
Eye-head motion was studied pre-, in- and postflight during single voluntary head turns. A transient increase in vestibulo-ocular reflex (VOR) gain occurred early in the flight, but later trended toward normal. This increased gain was produced by a relative increase in eye counterrotation velocity. Asymmetries in gain with right and left turns also occurred, caused by asymmetries in eye counterrotation velocities. These findings were remarkably similar to those from Soviet primate studies using gaze fixation targets, except the human study trended more rapidly toward normal. These findings differ substantially from those measuring VOR gain by head oscillation, in which no significant changes were found inflight. No visual disturbances were noted in either test condition or in normal activities. These head turn studies are the only ones to date documenting any functional change in VOR in weightlessness.
Neurons compute internal models of the physical laws of motion.
Angelaki, Dora E; Shaikh, Aasef G; Green, Andrea M; Dickman, J David
2004-07-29
A critical step in self-motion perception and spatial awareness is the integration of motion cues from multiple sensory organs that individually do not provide an accurate representation of the physical world. One of the best-studied sensory ambiguities is found in visual processing, and arises because of the inherent uncertainty in detecting the motion direction of an untextured contour moving within a small aperture. A similar sensory ambiguity arises in identifying the actual motion associated with linear accelerations sensed by the otolith organs in the inner ear. These internal linear accelerometers respond identically during translational motion (for example, running forward) and gravitational accelerations experienced as we reorient the head relative to gravity (that is, head tilt). Using new stimulus combinations, we identify here cerebellar and brainstem motion-sensitive neurons that compute a solution to the inertial motion detection problem. We show that the firing rates of these populations of neurons reflect the computations necessary to construct an internal model representation of the physical equations of motion.
Development of a vision non-contact sensing system for telerobotic applications
NASA Astrophysics Data System (ADS)
Karkoub, M.; Her, M.-G.; Ho, M.-I.; Huang, C.-C.
2013-08-01
The study presented here describes a novel vision-based motion detection system for telerobotic operations such as distant surgical procedures. The system uses a CCD camera and image processing to detect the motion of a master robot or operator. Colour tags are placed on the arm and head of a human operator to detect the up/down, right/left motion of the head as well as the right/left motion of the arm. The motion of the colour tags are used to actuate a slave robot or a remote system. The determination of the colour tags' motion is achieved through image processing using eigenvectors and colour system morphology and the relative head, shoulder and wrist rotation angles through inverse dynamics and coordinate transformation. A program is used to transform this motion data into motor control commands and transmit them to a slave robot or remote system through wireless internet. The system performed well even in complex environments with errors that did not exceed 2 pixels with a response time of about 0.1 s. The results of the experiments are available at: http://www.youtube.com/watch?v=yFxLaVWE3f8 and http://www.youtube.com/watch?v=_nvRcOzlWHw
The Contribution of Head Movement to the Externalization and Internalization of Sounds
Brimijoin, W. Owen; Boyd, Alan W.; Akeroyd, Michael A.
2013-01-01
Background When stimuli are presented over headphones, they are typically perceived as internalized; i.e., they appear to emanate from inside the head. Sounds presented in the free-field tend to be externalized, i.e., perceived to be emanating from a source in the world. This phenomenon is frequently attributed to reverberation and to the spectral characteristics of the sounds: those sounds whose spectrum and reverberation matches that of free-field signals arriving at the ear canal tend to be more frequently externalized. Another factor, however, is that the virtual location of signals presented over headphones moves in perfect concert with any movements of the head, whereas the location of free-field signals moves in opposition to head movements. The effects of head movement have not been systematically disentangled from reverberation and/or spectral cues, so we measured the degree to which movements contribute to externalization. Methodology/Principal Findings We performed two experiments: 1) Using motion tracking and free-field loudspeaker presentation, we presented signals that moved in their spatial location to match listeners’ head movements. 2) Using motion tracking and binaural room impulse responses, we presented filtered signals over headphones that appeared to remain static relative to the world. The results from experiment 1 showed that free-field signals from the front that move with the head are less likely to be externalized (23%) than those that remain fixed (63%). Experiment 2 showed that virtual signals whose position was fixed relative to the world are more likely to be externalized (65%) than those fixed relative to the head (20%), regardless of the fidelity of the individual impulse responses. Conclusions/Significance Head movements play a significant role in the externalization of sound sources. These findings imply tight integration between binaural cues and self motion cues and underscore the importance of self motion for spatial auditory perception. PMID:24312677
Augustine, Catherine; Makofsky, Howard W; Britt, Christina; Adomsky, Barbara; Deshler, Jennifer Matire; Ramirez, Paula; Douris, Peter
2008-04-01
Numerous studies suggest that temporomandibular disorders may be associated with forward head posture. The current study presents a need for an intervention that will effectively facilitate an ideal postural alignment of the head. The Occivator (Posteocentric Systems, Mastic Beach, NY) is an intervention speculated to improve forward head posture (FHP). However there has not been a randomized study to correlate use of the Occivator with improvement of FHP. The purpose of this study was to evaluate the effectiveness of the Occivator as a therapeutic intervention for the correction of FHP. Using a plumb line, twenty-nine (29) subjects were selected on the basis of having FHP. The CROM (cervical range of motion) device was used to determine measurement of forward head position for each group, pre and post an eight week period. The experimental group followed a specific protocol of 20 minutes of stretches and exercises on the Occivator, two times a week for eight weeks. The control group did not receive any intervention. The experimental group as compared to the control group, demonstrated significant improvement for forward head posture (p = .02). Further research is needed to evaluate the effectiveness of the Occivator.
Self-motion perception: assessment by real-time computer-generated animations
NASA Technical Reports Server (NTRS)
Parker, D. E.; Phillips, J. O.
2001-01-01
We report a new procedure for assessing complex self-motion perception. In three experiments, subjects manipulated a 6 degree-of-freedom magnetic-field tracker which controlled the motion of a virtual avatar so that its motion corresponded to the subjects' perceived self-motion. The real-time animation created by this procedure was stored using a virtual video recorder for subsequent analysis. Combined real and illusory self-motion and vestibulo-ocular reflex eye movements were evoked by cross-coupled angular accelerations produced by roll and pitch head movements during passive yaw rotation in a chair. Contrary to previous reports, illusory self-motion did not correspond to expectations based on semicircular canal stimulation. Illusory pitch head-motion directions were as predicted for only 37% of trials; whereas, slow-phase eye movements were in the predicted direction for 98% of the trials. The real-time computer-generated animations procedure permits use of naive, untrained subjects who lack a vocabulary for reporting motion perception and is applicable to basic self-motion perception studies, evaluation of motion simulators, assessment of balance disorders and so on.
Visual perception of axes of head rotation
Arnoldussen, D. M.; Goossens, J.; van den Berg, A. V.
2013-01-01
Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. (1) Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit. We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow's rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals. (2) Do transformed visual self-rotation signals reflect the arrangement of the semi-circular canals (SCC)? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those Blood oxygenated level-dependent (BOLD) signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes. (3) We investigated if subject's sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is not arranged into the SCC frame. PMID:23919087
Processing of angular motion and gravity information through an internal model.
Laurens, Jean; Straumann, Dominik; Hess, Bernhard J M
2010-09-01
The vestibular organs in the base of the skull provide important information about head orientation and motion in space. Previous studies have suggested that both angular velocity information from the semicircular canals and information about head orientation and translation from the otolith organs are centrally processed in an internal model of head motion, using the principles of optimal estimation. This concept has been successfully applied to model behavioral responses to classical vestibular motion paradigms. This study measured the dynamic of the vestibuloocular reflex during postrotatory tilt, tilt during the optokinetic afternystagmus, and off-vertical axis rotation. The influence of otolith signal on the VOR was systematically varied by using a series of tilt angles. We found that the time constants of responses varied almost identically as a function of gravity in these paradigms. We show that Bayesian modeling could predict the experimental results in an accurate and consistent manner. In contrast to other approaches, the Bayesian model also provides a plausible explanation of why these vestibulooculo motor responses occur as a consequence of an internal process of optimal motion estimation.
Indian and African plate motions driven by the push force of the Réunion plume head.
Cande, Steven C; Stegman, Dave R
2011-07-06
Mantle plumes are thought to play an important part in the Earth's tectonics, yet it has been difficult to isolate the effect that plumes have on plate motions. Here we analyse the plate motions involved in two apparently disparate events--the unusually rapid motion of India between 67 and 52 million years ago and a contemporaneous, transitory slowing of Africa's motion--and show that the events are coupled, with the common element being the position of the Indian and African plates relative to the location of the Réunion plume head. The synchroneity of these events suggests that they were both driven by the force of the Réunion plume head. The recognition of this plume force has substantial tectonic implications: the speed-up and slowdown of India, the possible cessation of convergence between Africa and Eurasia in the Palaeocene epoch and the enigmatic bends of the fracture zones on the Southwest Indian Ridge can all be attributed to the Réunion plume. ©2011 Macmillan Publishers Limited. All rights reserved
NASA Technical Reports Server (NTRS)
Perrone, J. A.; Stone, L. S.
1998-01-01
We have proposed previously a computational neural-network model by which the complex patterns of retinal image motion generated during locomotion (optic flow) can be processed by specialized detectors acting as templates for specific instances of self-motion. The detectors in this template model respond to global optic flow by sampling image motion over a large portion of the visual field through networks of local motion sensors with properties similar to those of neurons found in the middle temporal (MT) area of primate extrastriate visual cortex. These detectors, arranged within cortical-like maps, were designed to extract self-translation (heading) and self-rotation, as well as the scene layout (relative distances) ahead of a moving observer. We then postulated that heading from optic flow is directly encoded by individual neurons acting as heading detectors within the medial superior temporal (MST) area. Others have questioned whether individual MST neurons can perform this function because some of their receptive-field properties seem inconsistent with this role. To resolve this issue, we systematically compared MST responses with those of detectors from two different configurations of the model under matched stimulus conditions. We found that the characteristic physiological properties of MST neurons can be explained by the template model. We conclude that MST neurons are well suited to support self-motion estimation via a direct encoding of heading and that the template model provides an explicit set of testable hypotheses that can guide future exploration of MST and adjacent areas within the superior temporal sulcus.
An analysis of a discrete complex skill using Bernstein's stages of learning.
Smith, D R; McCabe, D R; Wilkerson, J D
2001-08-01
The purpose of this study was to provide quantitative data about changes in coordination after practicing a racquetball forehand drive serve. Novice women (N = 10) were videotaped before and after 10 min. of practicing a racquetball forehand drive serve on Day 1, and after 10-min. practice sessions on consecutive Days 2 through 5. The PEAK5 Motion Measurement System was used to evaluate the following dependent variables: (a) range of motion of the wrist, elbow, upper torso, and pelvis from backswing to ball contact: (b) racket head velocity at ball contact; and (c) coordination. Coordination was evaluated based on analysis of the angular velocity graphs of each performance to assess sequencing and timing of the segmental contributions. Shared positive contribution was assessed between adjacent 2-segment combinations: pelvis-torso and elbow-wrist. A repeated-measures analysis of variance indicated racket velocity, pelvic rotation, and upper torso rotation significantly increased over the 5 days of practice. Although participants increased their pelvic and torso ranges of motion and racket velocity, improvement in coordination was not documented.
NASA Technical Reports Server (NTRS)
Parker, D. E.; Wood, D. L.; Gulledge, W. L.; Goodrich, R. L.
1979-01-01
Two types of experiments concerning the estimated magnitude of self-motion during exposure to linear oscillation on a parallel swing are described in this paper. Experiment I examined changes in magnitude estimation as a function of variation of the subject's head orientation, and Experiments II a, II b, and II c assessed changes in magnitude estimation performance following exposure to sustained, 'intense' linear oscillation (fatigue-inducting stimulation). The subjects' performance was summarized employing Stevens' power law R = k x S to the nth, where R is perceived self-motion magnitude, k is a constant, S is amplitude of linear oscillation, and n is an exponent). The results of Experiment I indicated that the exponents, n, for the magnitude estimation functions varied with head orientation and were greatest when the head was oriented 135 deg off the vertical. In Experiments II a-c, the magnitude estimation function exponents were increased following fatigue. Both types of experiments suggest ways in which the vestibular system's contribution to a spatial orientation perceptual system may vary. This variability may be a contributing factor to the development of pilot/astronaut disorientation and may also be implicated in the occurrence of motion sickness.
A rigid motion correction method for helical computed tomography (CT)
NASA Astrophysics Data System (ADS)
Kim, J.-H.; Nuyts, J.; Kyme, A.; Kuncic, Z.; Fulton, R.
2015-03-01
We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed and the phantom. Motion correction was performed by restoring projection consistency using data from the motion tracking system, and reconstructing with an iterative fully 3D algorithm. Motion correction accuracy was evaluated by comparing reconstructed images with a stationary reference scan. We also investigated the effects on accuracy of tracker sampling rate, measurement jitter, interpolation of tracker measurements, and the synchronization of motion data and CT projections. After optimization of these aspects, motion corrected images corresponded remarkably closely to images of the stationary phantom with correlation and similarity coefficients both above 0.9. We performed a simulation study using volunteer head motion and found similarly that our method is capable of compensating effectively for realistic human head movements. To the best of our knowledge, this is the first practical demonstration of generalized rigid motion correction in helical CT. Its clinical value, which we have yet to explore, may be significant. For example it could reduce the necessity for repeat scans and resource-intensive anesthetic and sedation procedures in patient groups prone to motion, such as young children. It is not only applicable to dedicated CT imaging, but also to hybrid PET/CT and SPECT/CT, where it could also ensure an accurate CT image for lesion localization and attenuation correction of the functional image data.
Egmose, Ida; Varni, Giovanna; Cordes, Katharina; Smith-Nielsen, Johanne; Væver, Mette S.; Køppe, Simo; Cohen, David; Chetouani, Mohamed
2017-01-01
Bodily movements are an essential component of social interactions. However, the role of movement in early mother-infant interaction has received little attention in the research literature. The aim of the present study was to investigate the relationship between automatically extracted motion features and interaction quality in mother-infant interactions at 4 and 13 months. The sample consisted of 19 mother-infant dyads at 4 months and 33 mother-infant dyads at 13 months. The coding system Coding Interactive Behavior (CIB) was used for rating the quality of the interactions. Kinetic energy of upper-body, arms and head motion was calculated and used as segmentation in order to extract coarse- and fine-grained motion features. Spearman correlations were conducted between the composites derived from the CIB and the coarse- and fine-grained motion features. At both 4 and 13 months, longer durations of maternal arm motion and infant upper-body motion were associated with more aversive interactions, i.e., more parent-led interactions and more infant negativity. Further, at 4 months, the amount of motion silence was related to more adaptive interactions, i.e., more sensitive and child-led interactions. Analyses of the fine-grained motion features showed that if the mother coordinates her head movements with her infant's head movements, the interaction is rated as more adaptive in terms of less infant negativity and less dyadic negative states. We found more and stronger correlations between the motion features and the interaction qualities at 4 compared to 13 months. These results highlight that motion features are related to the quality of mother-infant interactions. Factors such as infant age and interaction set-up are likely to modify the meaning and importance of different motion features. PMID:29326626
Egmose, Ida; Varni, Giovanna; Cordes, Katharina; Smith-Nielsen, Johanne; Væver, Mette S; Køppe, Simo; Cohen, David; Chetouani, Mohamed
2017-01-01
Bodily movements are an essential component of social interactions. However, the role of movement in early mother-infant interaction has received little attention in the research literature. The aim of the present study was to investigate the relationship between automatically extracted motion features and interaction quality in mother-infant interactions at 4 and 13 months. The sample consisted of 19 mother-infant dyads at 4 months and 33 mother-infant dyads at 13 months. The coding system Coding Interactive Behavior (CIB) was used for rating the quality of the interactions. Kinetic energy of upper-body, arms and head motion was calculated and used as segmentation in order to extract coarse- and fine-grained motion features. Spearman correlations were conducted between the composites derived from the CIB and the coarse- and fine-grained motion features. At both 4 and 13 months, longer durations of maternal arm motion and infant upper-body motion were associated with more aversive interactions, i.e., more parent-led interactions and more infant negativity. Further, at 4 months, the amount of motion silence was related to more adaptive interactions, i.e., more sensitive and child-led interactions. Analyses of the fine-grained motion features showed that if the mother coordinates her head movements with her infant's head movements, the interaction is rated as more adaptive in terms of less infant negativity and less dyadic negative states. We found more and stronger correlations between the motion features and the interaction qualities at 4 compared to 13 months. These results highlight that motion features are related to the quality of mother-infant interactions. Factors such as infant age and interaction set-up are likely to modify the meaning and importance of different motion features.
Convergent properties of vestibular-related brain stem neurons in the gerbil
NASA Technical Reports Server (NTRS)
Kaufman, G. D.; Shinder, M. E.; Perachio, A. A.
2000-01-01
Three classes of vestibular-related neurons were found in and near the prepositus and medial vestibular nuclei of alert or decerebrate gerbils, those responding to: horizontal translational motion, horizontal head rotation, or both. Their distribution ratios were 1:2:2, respectively. Many cells responsive to translational motion exhibited spatiotemporal characteristics with both response gain and phase varying as a function of the stimulus vector angle. Rotationally sensitive neurons were distributed as Type I, II, or III responses (sensitive to ipsilateral, contralateral, or both directions, respectively) in the ratios of 4:6:1. Four tested factors shaped the response dynamics of the sampled neurons: canal-otolith convergence, oculomotor-related activity, rotational Type (I or II), and the phase of the maximum response. Type I nonconvergent cells displayed increasing gains with increasing rotational stimulus frequency (0.1-2.0 Hz, 60 degrees /s), whereas Type II neurons with convergent inputs had response gains that markedly decreased with increasing translational stimulus frequency (0.25-2.0 Hz, +/-0.1 g). Type I convergent and Type II nonconvergent neurons exhibited essentially flat gains across the stimulus frequency range. Oculomotor-related activity was noted in 30% of the cells across all functional types, appearing as burst/pause discharge patterns related to the fast phase of nystagmus during head rotation. Oculomotor-related activity was correlated with enhanced dynamic range compared with the same category that had no oculomotor-related response. Finally, responses that were in-phase with head velocity during rotation exhibited greater gains with stimulus frequency increments than neurons with out-of-phase responses. In contrast, for translational motion, neurons out of phase with head acceleration exhibited low-pass characteristics, whereas in-phase neurons did not. Data from decerebrate preparations revealed that although similar response types could be detected, the sampled cells generally had lower background discharge rates, on average one-third lower response gains, and convergent properties that differed from those found in the alert animals. On the basis of the dynamic response of identified cell types, we propose a pair of models in which inhibitory input from vestibular-related neurons converges on oculomotor neurons with excitatory inputs from the vestibular nuclei. Simple signal convergence and combinations of different types of vestibular labyrinth information can enrich the dynamic characteristics of the rotational and translational vestibuloocular responses.
Upper body kinematics in patients with cerebellar ataxia.
Conte, Carmela; Pierelli, Francesco; Casali, Carlo; Ranavolo, Alberto; Draicchio, Francesco; Martino, Giovanni; Harfoush, Mahmoud; Padua, Luca; Coppola, Gianluca; Sandrini, Giorgio; Serrao, Mariano
2014-12-01
Although abnormal oscillations of the trunk are a common clinical feature in patients with cerebellar ataxia, the kinematic behaviour of the upper body in ataxic patients has yet to be investigated in quantitative studies. In this study, an optoelectronic motion analysis system was used to measure the ranges of motion (ROMs) of the head and trunk segments in the sagittal, frontal and yaw planes in 16 patients with degenerative cerebellar ataxia during gait at self-selected speed. The data obtained were compared with those collected in a gender-, age- and gait speed-matched sample of healthy subjects and correlated with gait variables (time-distance means and coefficients of variation) and clinical variables (disease onset, duration and severity). The results showed significantly larger head and/or trunk ROMs in ataxic patients compared with controls in all three spatial planes, and significant correlations between trunk ROMs and disease duration and severity (in sagittal and frontal planes) and time-distance parameters (in the yaw plane), and between both head and trunk ROMs and swing phase duration variability (in the sagittal plane). Furthermore, the ataxic patients showed a flexed posture of both the head and the trunk during walking. In conclusion, our study revealed abnormal motor behaviour of the upper body in ataxic patients, mainly resulting in a flexed posture and larger oscillations of the head and trunk. The results of the correlation analyses suggest that the longer and more severe the disease, the larger the upper body oscillations and that large trunk oscillations may explain some aspects of gait variability. These results suggest the need of specific rehabilitation treatments or the use of elastic orthoses that may be particularly useful to reduce trunk oscillations and improve dynamic stability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dale, Gregory E.; Holloway, Michael Andrew; Pulliam, Elias Noel
2015-03-30
This design is intended to replace the current mirror setup being used for the NorthStar Moly 99 project in order to monitor the target coupon. The existing setup has limited movement for camera alignment and is difficult to align properly. This proposed conceptual design for a water cooled mirror will allow for greater thermal transfer between the mirror and the water block. It will also improve positioning of the mirror by using flexible vacuum hosing and a ball head joint capable of a wide range of motion. Incorporating this design into the target monitoring system will provide more efficient coolingmore » of the mirror which will improve the amount of diffraction caused by the heating of the mirror. The process of aligning the mirror for accurate position will be greatly improved by increasing the range of motion by offering six degrees of freedom.« less
Drift Reduction in Pedestrian Navigation System by Exploiting Motion Constraints and Magnetic Field
Ilyas, Muhammad; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok
2016-01-01
Pedestrian navigation systems (PNS) using foot-mounted MEMS inertial sensors use zero-velocity updates (ZUPTs) to reduce drift in navigation solutions and estimate inertial sensor errors. However, it is well known that ZUPTs cannot reduce all errors, especially as heading error is not observable. Hence, the position estimates tend to drift and even cyclic ZUPTs are applied in updated steps of the Extended Kalman Filter (EKF). This urges the use of other motion constraints for pedestrian gait and any other valuable heading reduction information that is available. In this paper, we exploit two more motion constraints scenarios of pedestrian gait: (1) walking along straight paths; (2) standing still for a long time. It is observed that these motion constraints (called “virtual sensor”), though considerably reducing drift in PNS, still need an absolute heading reference. One common absolute heading estimation sensor is the magnetometer, which senses the Earth’s magnetic field and, hence, the true heading angle can be calculated. However, magnetometers are susceptible to magnetic distortions, especially in indoor environments. In this work, an algorithm, called magnetic anomaly detection (MAD) and compensation is designed by incorporating only healthy magnetometer data in the EKF updating step, to reduce drift in zero-velocity updated INS. Experiments are conducted in GPS-denied and magnetically distorted environments to validate the proposed algorithms. PMID:27618056
NASA Technical Reports Server (NTRS)
Oman, C. M.; Lichtenberg, B. K.; Money, K. E.; McCoy, R. K.
1986-01-01
Space sickness symptoms were observed by 4 specially trained observers on Spacelab-1. Three reported persistent symptoms, and vomited repeatedly during the first and/or second day of flight. Head movements on all axes were provocative, particularly in pitch and roll. Head acceleration data recorded from 2 symptomatic crewmen showed that after several hours of physical activity in orbit, symptoms appeared, and thereafter both crewmen were compelled to limit head movements. Firm body contact with motionless surfaces helped alleviate symptoms. When crewmembers floated into unfamiliar body orientations in the cabin, inherent ambiguities in static visual orientation cues sometimes produced spatial reorientation episodes which were also provocative. Symptoms largely resembled those of other forms of prolonged motion sickness, superimposed upon other symptoms attributable to fluid shift. All 4 eventually used anti-motion sickness drugs. When they did, vomiting frequency was reduced. By the 4th day, symptoms subsided, and head accelerations again increased in magnitude and variability. Sickness intensity in orbit was not predicted by statistically concordant results of 6 acute preflight susceptibility tests. However, results from a longer duration preflight prism goggles test showed an apparent correlation. All subjects were asymptomatic making head movements in parabolic flight 4 days after the mission, but not 1 year later. Overall, results support the view that space sickness is a motion sickness.
Sasaki, Ryo; Angelaki, Dora E.
2017-01-01
We use visual image motion to judge the movement of objects, as well as our own movements through the environment. Generally, image motion components caused by object motion and self-motion are confounded in the retinal image. Thus, to estimate heading, the brain would ideally marginalize out the effects of object motion (or vice versa), but little is known about how this is accomplished neurally. Behavioral studies suggest that vestibular signals play a role in dissociating object motion and self-motion, and recent computational work suggests that a linear decoder can approximate marginalization by taking advantage of diverse multisensory representations. By measuring responses of MSTd neurons in two male rhesus monkeys and by applying a recently-developed method to approximate marginalization by linear population decoding, we tested the hypothesis that vestibular signals help to dissociate self-motion and object motion. We show that vestibular signals stabilize tuning for heading in neurons with congruent visual and vestibular heading preferences, whereas they stabilize tuning for object motion in neurons with discrepant preferences. Thus, vestibular signals enhance the separability of joint tuning for object motion and self-motion. We further show that a linear decoder, designed to approximate marginalization, allows the population to represent either self-motion or object motion with good accuracy. Decoder weights are broadly consistent with a readout strategy, suggested by recent computational work, in which responses are decoded according to the vestibular preferences of multisensory neurons. These results demonstrate, at both single neuron and population levels, that vestibular signals help to dissociate self-motion and object motion. SIGNIFICANCE STATEMENT The brain often needs to estimate one property of a changing environment while ignoring others. This can be difficult because multiple properties of the environment may be confounded in sensory signals. The brain can solve this problem by marginalizing over irrelevant properties to estimate the property-of-interest. We explore this problem in the context of self-motion and object motion, which are inherently confounded in the retinal image. We examine how diversity in a population of multisensory neurons may be exploited to decode self-motion and object motion from the population activity of neurons in macaque area MSTd. PMID:29030435
Delgado Reyes, Lourdes M; Bohache, Kevin; Wijeakumar, Sobanawartiny; Spencer, John P
2018-04-01
Motion artifacts are often a significant component of the measured signal in functional near-infrared spectroscopy (fNIRS) experiments. A variety of methods have been proposed to address this issue, including principal components analysis (PCA), correlation-based signal improvement (CBSI), wavelet filtering, and spline interpolation. The efficacy of these techniques has been compared using simulated data; however, our understanding of how these techniques fare when dealing with task-based cognitive data is limited. Brigadoi et al. compared motion correction techniques in a sample of adult data measured during a simple cognitive task. Wavelet filtering showed the most promise as an optimal technique for motion correction. Given that fNIRS is often used with infants and young children, it is critical to evaluate the effectiveness of motion correction techniques directly with data from these age groups. This study addresses that problem by evaluating motion correction algorithms implemented in HomER2. The efficacy of each technique was compared quantitatively using objective metrics related to the physiological properties of the hemodynamic response. Results showed that targeted PCA (tPCA), spline, and CBSI retained a higher number of trials. These techniques also performed well in direct head-to-head comparisons with the other approaches using quantitative metrics. The CBSI method corrected many of the artifacts present in our data; however, this approach produced sometimes unstable HRFs. The targeted PCA and spline methods proved to be the most robust, performing well across all comparison metrics. When compared head to head, tPCA consistently outperformed spline. We conclude, therefore, that tPCA is an effective technique for correcting motion artifacts in fNIRS data from young children.
Project Physics Reader 1, Concepts of Motion.
ERIC Educational Resources Information Center
Harvard Univ., Cambridge, MA. Harvard Project Physics.
As a supplement to Project Physics Unit 1, 21 articles are presented in this reader. Concepts of motion are discussed under headings: motion, motion in words, representation of movement, introducing vectors, Galileo's discussion of projectile motion, Newton's laws of dynamics, the dynamics of a golf club, report on Tait's lecture on force, and bad…
The Video Head Impulse Test to Assess the Efficacy of Vestibular Implants in Humans
Guinand, Nils; Van de Berg, Raymond; Cavuscens, Samuel; Ranieri, Maurizio; Schneider, Erich; Lucieer, Floor; Kingma, Herman; Guyot, Jean-Philippe; Pérez Fornos, Angélica
2017-01-01
The purpose of this study was to evaluate whether it is possible to restore the high-frequency angular vestibulo-ocular reflex (aVOR) in patients suffering from a severe bilateral vestibulopathy (BV) and implanted with a vestibular implant prototype. Three patients (S1–3) participated in the study. They received a prototype vestibular implant with one to three electrode branches implanted in the proximity of the ampullary branches of the vestibular nerve. Five electrodes were available for electrical stimulation: one implanted in proximity of the left posterior ampullary nerve in S1, one in the left lateral and another one in the superior ampullary nerves in S2, and one in the right lateral and another one in the superior ampullary nerves in S3. The high-frequency aVOR was assessed using the video head impulse test (EyeSeeCam; EyeSeeTec, Munich, Germany), while motion-modulated electrical stimulation was delivered via one of the implanted vestibular electrodes at a time. aVOR gains were compared to control measurements obtained in the same patients when the device was not activated. In three out of the five tested electrodes the aVOR gain increased monotonically with increased stimulation strength when head impulses were delivered in the plane of the implanted canal. In these cases, gains ranging from 0.4 to values above 1 were measured. A “reversed” aVOR could also be generated when inversed stimulation paradigms were used. In most cases, the gain for excitatory head impulses was superior to that recorded for inhibitory head impulses, consistent with unilateral vestibular stimulation. Improvements of aVOR gain were generally accompanied by a concomitant decrease of corrective saccades, providing additional evidence of an effective aVOR. High inter-electrode and inter-subject variability were observed. These results, together with previous research, demonstrate that it is possible to restore the aVOR in a broad frequency range using motion-modulated electrical stimulation of the vestibular afferents. This provides additional encouraging evidence of the possibility of achieving a useful rehabilitation alternative for patients with BV in the near future. PMID:29184530
Williams, James A; Eddleman, Laura; Pantone, Amy; Martinez, Regina; Young, Stephen; Van Der Pol, Barbara
2014-08-01
Next-generation diagnostics for Chlamydia trachomatis and Neisseria gonorrhoeae are available on semi- or fully-automated platforms. These systems require less hands-on time than older platforms and are user friendly. Four automated systems, the ABBOTT m2000 system, Becton Dickinson Viper System with XTR Technology, Gen-Probe Tigris DTS system, and Roche cobas 4800 system, were evaluated for total run time, hands-on time, and walk-away time. All of the systems evaluated in this time-motion study were able to complete a diagnostic test run within an 8-h work shift, instrument setup and operation were straightforward and uncomplicated, and walk-away time ranged from approximately 90 to 270 min in a head-to-head comparison of each system. All of the automated systems provide technical staff with increased time to perform other tasks during the run, offer easy expansion of the diagnostic test menu, and have the ability to increase specimen throughput. © 2013 Society for Laboratory Automation and Screening.
Kinect based real-time position calibration for nasal endoscopic surgical navigation system
NASA Astrophysics Data System (ADS)
Fan, Jingfan; Yang, Jian; Chu, Yakui; Ma, Shaodong; Wang, Yongtian
2016-03-01
Unanticipated, reactive motion of the patient during skull based tumor resective surgery is the source of the consequence that the nasal endoscopic tracking system is compelled to be recalibrated. To accommodate the calibration process with patient's movement, this paper developed a Kinect based Real-time positional calibration method for nasal endoscopic surgical navigation system. In this method, a Kinect scanner was employed as the acquisition part of the point cloud volumetric reconstruction of the patient's head during surgery. Then, a convex hull based registration algorithm aligned the real-time image of the patient head with a model built upon the CT scans performed in the preoperative preparation to dynamically calibrate the tracking system if a movement was detected. Experimental results confirmed the robustness of the proposed method, presenting a total tracking error within 1 mm under the circumstance of relatively violent motions. These results point out the tracking accuracy can be retained stably and the potential to expedite the calibration of the tracking system against strong interfering conditions, demonstrating high suitability for a wide range of surgical applications.
Ikari, Yasuhiko; Nishio, Tomoyuki; Makishi, Yoko; Miya, Yukari; Ito, Kengo; Koeppe, Robert A; Senda, Michio
2012-08-01
Head motion during 30-min (six 5-min frames) brain PET scans starting 30 min post-injection of FDG was evaluated together with the effect of post hoc motion correction between frames in J-ADNI multicenter study carried out in 24 PET centers on a total of 172 subjects consisting of 81 normal subjects, 55 mild cognitive impairment (MCI) and 36 mild Alzheimer's disease (AD) patients. Based on the magnitude of the between-frame co-registration parameters, the scans were classified into six levels (A-F) of motion degree. The effect of motion and its correction was evaluated using between-frame variation of the regional FDG uptake values on ROIs placed over cerebral cortical areas. Although AD patients tended to present larger motion (motion level E or F in 22 % of the subjects) than MCI (3 %) and normal (4 %) subjects, unignorable motion was observed in a small number of subjects in the latter groups as well. The between-frame coefficient of variation (SD/mean) was 0.5 % in the frontal, 0.6 % in the parietal and 1.8 % in the posterior cingulate ROI for the scans of motion level 1. The respective values were 1.5, 1.4, and 3.6 % for the scans of motion level F, but reduced by the motion correction to 0.5, 0.4 and 0.8 %, respectively. The motion correction changed the ROI value for the posterior cingulate cortex by 11.6 % in the case of severest motion. Substantial head motion occurs in a fraction of subjects in a multicenter setup which includes PET centers lacking sufficient experience in imaging demented patients. A simple frame-by-frame co-registration technique that can be applied to any PET camera model is effective in correcting for motion and improving quantitative capability.
The choice of speed and clearance for RAS on 3D method
NASA Astrophysics Data System (ADS)
Wang, Jian-Fang; Li, Ji-De; Cai, Xin-Gong
2003-12-01
In this paper, a 3D source distribution technique is used to calculate the coupled motions between two ships which advance in the wave with the same speed. The numerical results of coupled motions for a frigate and a supply ship have a good agreement with the experimental results. Based on the 3D coupled motions of two ships, a spectral analysis is employed to clearly observe the effect of speed, clearance and wave heading on the significant relative motion amplitude (SRMA) of two ships. The method presented in this paper will be helpful to select suitable clearance, speed and wave heading for underway replenishment at sea(RAS).
NASA Technical Reports Server (NTRS)
Kohl, R. L.
1991-01-01
The rotating chair test, a novel research technique for simulating motion sickness, is used to study the effect of nonsedating oral antihistamines in preventing or forestalling motion sickness. After receiving terfenadine, astemizole, doxepin, or placebo, four groups of male volunteers were rotated at accelerating speed, and they made head movements out of the axis of rotation until they perceived that vomiting would occur if additional head movements were made. Those pretreated with doxepin or terfenadine experienced a statistically significant prophylactic effect, as measured by increased tolerance to Coriolis stimulation. This suggests that selective peripheral H1 antihistamine action may protect against motion sickness.
Rhodin, M; Roepstorff, L; French, A; Keegan, K G; Pfau, T; Egenvall, A
2016-05-01
Lungeing is commonly used as part of standard lameness examinations in horses. Knowledge of how lungeing influences motion symmetry in sound horses is needed. The aim of this study was to objectively evaluate the symmetry of vertical head and pelvic motion during lungeing in a large number of horses with symmetric motion during straight line evaluation. Cross-sectional prospective study. A pool of 201 riding horses, all functioning well and considered sound by their owners, were evaluated in trot on a straight line and during lungeing to the left and right. From this pool, horses with symmetric vertical head and pelvic movement during the straight line trot (n = 94) were retained for analysis. Vertical head and pelvic movements were measured with body mounted uniaxial accelerometers. Differences between vertical maximum and minimum head (HDmax, HDmin) and pelvic (PDmax, PDmin) heights between left and right forelimb and hindlimb stances were compared between straight line trot and lungeing in either direction. Vertical head and pelvic movements during lungeing were more asymmetric than during trot on a straight line. Common asymmetric patterns seen in the head were more upward movement during push-off of the outside forelimb and less downward movement during impact of the inside limb. Common asymmetric patterns seen in the pelvis were less upward movement during push-off of the outside hindlimb and less downward movement of the pelvis during impact of the inside hindlimb. Asymmetric patterns in one lunge direction were frequently not the same as in the opposite direction. Lungeing induces systematic asymmetries in vertical head and pelvic motion patterns in horses that may not be the same in both directions. These asymmetries may mask or mimic fore- or hindlimb lameness. © 2015 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.
Cullen, Kathleen E.
2014-01-01
The vestibular system is vital for maintaining an accurate representation of self-motion. As one moves (or is moved) toward a new place in the environment, signals from the vestibular sensors are relayed to higher-order centers. It is generally assumed the vestibular system provides a veridical representation of head motion to these centers for the perception of self-motion and spatial memory. In support of this idea, evidence from lesion studies suggests that vestibular inputs are required for the directional tuning of head direction cells in the limbic system as well as neurons in areas of multimodal association cortex. However, recent investigations in monkeys and mice challenge the notion that early vestibular pathways encode an absolute representation of head motion. Instead, processing at the first central stage is inherently multimodal. This minireview highlights recent progress that has been made towards understanding how the brain processes and interprets self-motion signals encoded by the vestibular otoliths and semicircular canals during everyday life. The following interrelated questions are considered. What information is available to the higher-order centers that contribute to self-motion perception? How do we distinguish between our own self-generated movements and those of the external world? And lastly, what are the implications of differences in the processing of these active vs. passive movements for spatial memory? PMID:24454282
2014-01-01
Background The choice between operative or nonoperative treatment is questioned for partial articular fractures of the radial head that have at least 2 millimeters of articular step-off on at least one radiograph (defined as displaced), but less than 2 millimeter of gap between the fragments (defined as stable) and that are not associated with an elbow dislocation, interosseous ligament injury, or other fractures. These kinds of fractures are often classified as Mason type-2 fractures. Retrospective comparative studies suggest that operative treatment might be better than nonoperative treatment, but the long-term results of nonoperative treatment are very good. Most experts agree that problems like reduced range of motion, painful crepitation, nonunion or bony ankylosis are infrequent with both nonoperative and operative treatment of an isolated displaced partial articular fracture of the radial head, but determining which patients will have problems is difficult. A prospective, randomized comparison would help minimize bias and determine the balance between operative and nonoperative risks and benefits. Methods/Design The RAMBO trial (Radial Head – Amsterdam – Amphia – Boston - Others) is an international prospective, randomized, multicenter trial. The primary objective of this study is to compare patient related outcome defined by the ‘Disabilities of Arm, Shoulder and Hand (DASH) score’ twelve months after injury between operative and nonoperative treated patients. Adult patients with partial articular fractures of the radial head that comprise at least 1/3rd of the articular surface, have ≥ 2 millimeters of articular step-off but less than 2 millimeter of gap between the fragments will be enrolled. Secondary outcome measures will be the Mayo Elbow Performance Index (MEPI), the Oxford Elbow Score (OES), pain intensity through the ‘Numeric Rating Scale’, range of motion (flexion arc and rotational arc), radiographic appearance of the fracture (heterotopic ossification, radiocapitellar and ulnohumeral arthrosis, fracture healing, and signs of implant loosening or breakage) and adverse events (infection, nerve injury, secondary interventions) after one year. Discussion The successful completion of this trial will provide evidence on the best treatment for stable, displaced, partial articular fractures of the radial head. Trial registration The trial is registered at the Dutch Trial Register: NTR3413. PMID:24885637
Stackman, R W; Taube, J S
1998-11-01
Many neurons in the rat anterodorsal thalamus (ADN) and postsubiculum (PoS) fire selectively when the rat points its head in a specific direction in the horizontal plane, independent of the animal's location and ongoing behavior. The lateral mammillary nuclei (LMN) are interconnected with both the ADN and PoS and, therefore, are in a pivotal position to influence ADN/PoS neurophysiology. To further understand how the head direction (HD) cell signal is generated, we recorded single neurons from the LMN of freely moving rats. The majority of cells discharged as a function of one of three types of spatial correlates: (1) directional heading, (2) head pitch, or (3) angular head velocity (AHV). LMN HD cells exhibited higher peak firing rates and greater range of directional firing than that of ADN and PoS HD cells. LMN HD cells were modulated by angular head velocity, turning direction, and anticipated the rat's future HD by a greater amount of time (approximately 95 msec) than that previously reported for ADN HD cells (approximately 25 msec). Most head pitch cells discharged when the rostrocaudal axis of the rat's head was orthogonal to the horizontal plane. Head pitch cell firing was independent of the rat's location, directional heading, and its body orientation (i.e., the cell discharged whenever the rat pointed its head up, whether standing on all four limbs or rearing). AHV cells were categorized as fast or slow AHV cells depending on whether their firing rate increased or decreased in proportion to angular head velocity. These data demonstrate that LMN neurons code direction and angular motion of the head in both horizontal and vertical planes and support the hypothesis that the LMN play an important role in processing both egocentric and allocentric spatial information.
Effect of prophylactic trochanteric epiphyseodesis in older children with Perthes' disease.
Shah, Hitesh; Siddesh, Nandi D; Joseph, Benjamin; Nair, Sreekumaran N
2009-12-01
To evaluate the effect of prophylactic epiphyseodesis of the greater trochanter in Perthes' disease, 62 children with unilateral Perthes' disease who underwent trochanteric epiphyseodesis combined with varus osteotomy of the femur during the active stage of the disease (mean age at surgery: 8.4 y) and 20 controls were followed up until skeletal maturity. On radiographs taken at skeletal maturity, the articulo-trochanteric distance, the center-trochanteric distance, the length of the abductor lever arm, the neck-shaft angle, the radius of the femoral head, and the Reimer's migration index of normal and affected hips were measured. The shape of the femoral head was assessed according to the criteria of Mose. The range of hip motion, the strength of hip abduction, and limb lengths were measured and the Trendelenburg sign was elicited. The mean values of articulo-trochanteric distance and center-trochanteric distance were greater and the frequency of a positive Trendelenburg sign was less in children who had undergone trochanteric epiphyseodesis than in children who had no surgery (P<0.01). Trochanteric epiphyseodesis achieved optimal trochanteric growth arrest in 60% of operated children; the procedure was not effective in 30%, and in 10% of children there was overcorrection. Logistic regression analysis showed that the size of the femoral head at healing and the age at surgery were variables that significantly influenced the effectiveness of trochanteric growth arrest. At skeletal maturity, the mean shortening of the affected limb in operated children was 0.44 cm (SD 0.68 cm), whereas that of non-operated children was 0.86 cm (SD 0.78 cm) (P<0.05). The range of motion of the hip was excellent and there were no significant differences in the range of motion among children with optimal correction, under-correction, and overcorrection. A probability curve plotted on the basis of a logistic regression model suggests that effective trochanteric arrest may be achieved in a high proportion of children operated at or before 8.5 years of age and in half the children operated between the age of 8.5 years and 10 years. On the basis of this study, we recommend prophylactic epiphyseodesis of the greater trochanter as a means of minimizing trochanteric overgrowth and resultant Trendelenburg gait in older child with Perthes' disease.
The Development of Humeral Retrotorsion and Its Relationship to Throwing Sports.
Greenberg, Elliot M; Fernandez-Fernandez, Alicia; Lawrence, J Todd R; McClure, Philip
2015-01-01
Several investigations have noted that throwing athletes exhibit a more posteriorly oriented humeral head (humeral retrotorsion) in the dominant arm. This asymmetry is believed to represent an adaptive response to the stress of throwing that occurs during childhood. The significance of this alteration and factors that affect its development are currently not clear. Basic science, research studies, and review articles were searched through PubMed with search terms including humeral torsion, humeral retrotorsion, and with 1 of the following: pediatric, adult, baseball, pitching, shoulder, and range of motion. The references from each article were reviewed for further inclusion. This review included articles through March 2015. Clinical review. Level 4. The throwing motion creates stressors that result in bony adaptations that occur while skeletally immature. These osseous changes likely contribute to the observed shift in the arc of rotational range of motion noted in throwing athletes and may play a protective role against injury. However, too much or too little retrotorsion may predispose the shoulder to injury. The degree of "optimal" humeral retrotorsion and factors that influence its development are not fully understood. Evidence supports the assertion that the throwing motion creates stressors that alter bony anatomy while young. It is important to determine what specific factors affect this adaptation and its relationship to injury. © 2015 The Author(s).
The influence of musical cadence into aquatic jumping jacks kinematics.
Costa, Mário J; Oliveira, Cristiana; Teixeira, Genoveva; Marinho, Daniel A; Silva, António J; Barbosa, Tiago M
2011-01-01
The aim of this study was to analyze the relationships between the head-out aquatic exercise "Jumping jacks" kinematics and the musical cadence in healthy and fit subjects. Five young women, with at least one year of experience conducting head- out aquatic programs were videotaped in the frontal plane, with a pair of cameras providing a double projection (above and below the water surface). Subjects performed an incremental protocol of five bouts (120 b·min(-1), 135 b·min(-1), 150 b·min(-1), 165 b·min(-1) and 180 b·min(-1)) with 16 full cycles of the "Jumping jacks" exercise. Data processing and calculation of upper limbs' (i.e. hands), lower limbs' (i.e. feet) and center of mass' 2D linear velocity and displacement were computed with the software Ariel Performance Analysis System and applying the 2D-DLT algorithm. Subjects decreased the cycle period during the incremental protocol. Significant and negative relationships with the musical cadence were verified for the center of mass and upper limbs vertical displacement. On the other hand, for the lower limbs lateral velocity, a significant and positive relationship was observed. It is concluded that expert and fit subjects increase the lower limb's velocity to maintain the range of motion, while the upper limb's displacement is reduced to coupe the music cadence. Key pointsWhile performing the Jumping Jacks, expert and fit subjects increase their lower limbs segmental velocity to maintain the range of motion.The upper limbs displacement is reduced to maintain the music cadence.Expert and fit subjects present similar response for alternating or simultaneously head-out aquatic exercises when increasing the music cadence.
On the barn owl's visual pre-attack behavior: I. Structure of head movements and motion patterns.
Ohayon, Shay; van der Willigen, Robert F; Wagner, Hermann; Katsman, Igor; Rivlin, Ehud
2006-09-01
Barn owls exhibit a rich repertoire of head movements before taking off for prey capture. These movements occur mainly at light levels that allow for the visual detection of prey. To investigate these movements and their functional relevance, we filmed the pre-attack behavior of barn owls. Off-line image analysis enabled reconstruction of all six degrees of freedom of head movements. Three categories of head movements were observed: fixations, head translations and head rotations. The observed rotations contained a translational component. Head rotations did not follow Listing's law, but could be well described by a second-order surface, which indicated that they are in close agreement with Donder's law. Head translations did not contain any significant rotational components. Translations were further segmented into straight-line and curved paths. Translations along an axis perpendicular to the line of sight were similar to peering movements observed in other animals. We suggest that these basic motion elements (fixations, head rotations, translations along a straight line, and translation along a curved trajectory) may be combined to form longer and more complex behavior. We speculate that these head movements mainly underlie estimation of distance during prey capture.
Relating Neuronal to Behavioral Performance: Variability of Optomotor Responses in the Blowfly
Rosner, Ronny; Warzecha, Anne-Kathrin
2011-01-01
Behavioral responses of an animal vary even when they are elicited by the same stimulus. This variability is due to stochastic processes within the nervous system and to the changing internal states of the animal. To what extent does the variability of neuronal responses account for the overall variability at the behavioral level? To address this question we evaluate the neuronal variability at the output stage of the blowfly's (Calliphora vicina) visual system by recording from motion-sensitive interneurons mediating head optomotor responses. By means of a simple modelling approach representing the sensory-motor transformation, we predict head movements on the basis of the recorded responses of motion-sensitive neurons and compare the variability of the predicted head movements with that of the observed ones. Large gain changes of optomotor head movements have previously been shown to go along with changes in the animals' activity state. Our modelling approach substantiates that these gain changes are imposed downstream of the motion-sensitive neurons of the visual system. Moreover, since predicted head movements are clearly more reliable than those actually observed, we conclude that substantial variability is introduced downstream of the visual system. PMID:22066014
SU-E-J-193: Application of Surface Mapping in Detecting Swallowing for Head-&-Neck Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, D; Xie, X; Mehta, V
2015-06-15
Purpose: Recent evidence is emerging that long term swallowing function may be improved after radiotherapy for head-&-neck cancer if doses are limited to certain swallowing structures. Immobilization of patients with head-&-neck cancer is typically done with a mask. This mask, however, doesn’t limit patient swallowing. Patient voluntary or involuntary swallowing may introduce significant tumor motion, which can lead to suboptimal delivery. In this study, we have examined the feasibility of using surface mapping technology to detect patient swallowing during treatment and evaluated its magnitude. Methods: The C-RAD Catalyst system was used to detect the patient surface map. A volunteer lyingmore » on the couch was used to simulate the patient under treatment. A virtual marker was placed near the throat and was used to monitor the swallowing action. The target motion calculated by the Catalyst system through deformable registration was also collected. Two treatment isocenters, one placed close to the throat and the other placed posterior to the base-of-tongue, were used to check the sensitivity of surface mapping technique. Results: When the patient’s throat is not in the shadow of the patient’s chest, the Catalyst system can clearly identify the swallowing motion. In our tests, the vertical motion of the skin can reach to about 5mm. The calculated target motion can reach up to 1 cm. The magnitude of this calculated target motion is more dramatic when the plan isocenter is closer to the skin surface, which suggests that the Catalyst motion tracking technique is more sensitive to the swallowing motion with a shallower isocenter. Conclusion: Surface mapping can clearly identify patient swallowing during radiation treatment. This information can be used to evaluate the dosimetric impact of the involuntary swallowing. It may also be used to potentially gate head-&-neck radiation treatments. A prospective IRB approved study is currently enrolling patients in our institution. Research was funded through an Elekta grant.« less
Jones, Timothy A; Lee, Choongheon; Gaines, G Christopher; Grant, J W Wally
2015-04-01
Vestibular macular sensors are activated by a shearing motion between the otoconial membrane and underlying receptor epithelium. Shearing motion and sensory activation in response to an externally induced head motion do not occur instantaneously. The mechanically reactive elastic and inertial properties of the intervening tissue introduce temporal constraints on the transfer of the stimulus to sensors. Treating the otoconial sensory apparatus as an overdamped second-order mechanical system, we measured the governing long time constant (Τ(L)) for stimulus transfer from the head surface to epithelium. This provided the basis to estimate the corresponding upper cutoff for the frequency response curve for mouse otoconial organs. A velocity step excitation was used as the forcing function. Hypothetically, the onset of the mechanical response to a step excitation follows an exponential rise having the form Vel(shear) = U(1-e(-t/TL)), where U is the applied shearing velocity step amplitude. The response time of the otoconial apparatus was estimated based on the activation threshold of macular neural responses to step stimuli having durations between 0.1 and 2.0 ms. Twenty adult C57BL/6 J mice were evaluated. Animals were anesthetized. The head was secured to a shaker platform using a non-invasive head clip or implanted skull screws. The shaker was driven to produce a theoretical forcing step velocity excitation at the otoconial organ. Vestibular sensory evoked potentials (VsEPs) were recorded to measure the threshold for macular neural activation. The duration of the applied step motion was reduced systematically from 2 to 0.1 ms and response threshold determined for each duration (nine durations). Hypothetically, the threshold of activation will increase according to the decrease in velocity transfer occurring at shorter step durations. The relationship between neural threshold and stimulus step duration was characterized. Activation threshold increased exponentially as velocity step duration decreased below 1.0 ms. The time constants associated with the exponential curve were Τ(L) = 0.50 ms for the head clip coupling and T(L) = 0.79 ms for skull screw preparation. These corresponded to upper -3 dB frequency cutoff points of approximately 318 and 201 Hz, respectively. T(L) ranged from 224 to 379 across individual animals using the head clip coupling. The findings were consistent with a second-order mass-spring mechanical system. Threshold data were also fitted to underdamped models post hoc. The underdamped fits suggested natural resonance frequencies on the order of 278 to 448 Hz as well as the idea that macular systems in mammals are less damped than generally acknowledged. Although estimated indirectly, it is argued that these time constants reflect largely if not entirely the mechanics of transfer to the sensory apparatus. The estimated governing time constant of 0.50 ms for composite data predicts high frequency cutoffs of at least 318 Hz for the intact otoconial apparatus of the mouse.
Measurement of cervical flexor endurance following whiplash.
Kumbhare, Dinesh A; Balsor, Brad; Parkinson, William L; Harding Bsckin, Peter; Bedard, Michel; Papaioannou, Alexandra; Adachi, Jonathan D
2005-07-22
To investigate measurement properties of a practical test of cervical flexor endurance (CFE) in whiplash patients including inter-rater reliability, sensitivity to clinical change, criterion related validity against the Neck Disability Index (NDI), and discriminant validity for injured versus uninjured populations. Two samples were recruited, 81 whiplash patients, and a convenience sample of 160 subjects who were not seeking treatment and met criteria for normal pain and range of motion. CFE was measured using a stopwatch while the subject, in crook lying, held their head against gravity to fatigue. Inter-rater reliability in whiplash patients was in a range considered 'almost perfect' (Intraclass Correlation=0.96). CFE had greater inter-subject variability than the NDI or range of motion in any of three planes. However, the effect size for improvement in CFE over treatment was as large as the effect sizes for all of those measures. In multivariate regression, CFE changes accounted for changes on the NDI better than the three ranges of motion. CFE discriminated whiplash patients who were within six months of injury (n=71) from age and gender matched normals with high effect size (ES=1.5). These findings provide evidence of reliability and validity for CFE measurement, and demonstrate that CFE detects clinical improvements. Variance on CFE emphasizes the need to consider inter-, and intra-subject standard deviations to interpret scores.
Vivid Motor Imagery as an Adaptation Method for Head Turns on a Short-Arm Centrifuge
NASA Technical Reports Server (NTRS)
Newby, N. J.; Mast, F. W.; Natapoff, A.; Paloski, W. H.
2006-01-01
Artificial gravity (AG) has been proposed as a potential countermeasure to the debilitating physiological effects of long duration space flight. The most economical means of implementing AG may be through the use of a short-radius (2m or less) centrifuge. For such a device to produce gravitational forces comparable to those on earth requires rotation rates in excess of 20 revolutions per minute (rpm). Head turns made out of the plane of rotation at these rates, as may be necessary if exercise is combined with AG, result in cross-coupled stimuli (CCS) that cause adverse side effects including motion sickness, illusory sensations of motion, and inappropriate eye movements. Recent studies indicate that people can adapt to CCS and reduce these side effects by making multiple head turns during centrifuge sessions conducted over consecutive days. However, about 25% of the volunteers for these studies have difficulty tolerating the CCS adaptation paradigm and often drop out due to motion sickness symptoms. The goal of this investigation was to determine whether vivid motor imagery could be used as a pseudostimulus for adapting subjects to this unique environment. Twenty four healthy human subjects (14 males, 10 females), ranging in age from 21 to 48 years (mean 33, sd 7 years) took part in this study. The experimental stimuli were produced using the NASA JSC short-arm centrifuge (SAC). Subjects were oriented supinely on this device with the nose pointed toward the ceiling and head centered on the axis of rotation. Thus, centrifuge rotation was in the body roll plane. After ramp-up the SAC rotated clockwise at a constant rate of 23 rpm, producing a centrifugal force of approximately 1 g at the feet. Semicircular canal CCS were produced by having subjects make yaw head turns from the nose up (NU) position to the right ear down (RED) position and from RED to NU. Each head turn was completed in about one second, and a 30 second recovery period separated consecutive head movements. Participants were randomly assigned to one of three groups (n=8 per group): physical adapters (PA), mental adapters (MA), or a control group (CG). Each subject participated in a one hour test session on each of three consecutive days. Each test session consisted of an initial (preadaptation) period during which the subject performed six CCS maneuvers in the dark, followed by an adaptation period with internal lighting on the centrifuge, and a final (postadaptation) period during which six more CCS maneuvers were performed in the dark. For the PA group, the adaptation period consisted of performing 30 additional CCS maneuvers in the light. For the MA and CG group the centrifuge was ramped down to 0 rpm after the pre-adaptation period and ramped back up to 23 rpm before the post-adaptation period. For the both of these groups, the adaptation period consisted of making 30 CCS maneuvers in the light with the centrifuge stationary (so no cross-coupling occurred). MA group subjects were instructed to vividly imagine the provocative sensations produced by the preadaptation CCS maneuvers in terms of magnitude, duration, and direction of illusory body tilt, as well as any accompanying levels of motion sickness. CG group subjects were asked to answer low imagery content questions (trivial pursuit) during each adaptation period head turn. During the 30 second recovery following each head turn, psychophysical data were collected including self reports of motion sickness, magnitude and direction estimates of illusory body tilt, and the overall duration of these sensations. A multilevel mixed effects linear regression analysis performed on all response variables indicated that all three groups experienced some psychophysical adaptation across the three test sessions. For illusory tilt magnitude, the PA group exhibited the most overall adaptation, followed by the MA group, and the CG group. The slopes of these adaptation trajectories by group over day were significantly diffent from one another. For the perceived duration of sensations, the CG group again exhibited the least amount of adaptation. However, the rates of adaptation of the PA and the MA groups were indistinguishable, suggesting that the imagined pseudostimulus appeared to be just as effective a means of adaptation as the actual stimulus. The MA group's rate of adaptation to motion sickness symptoms was also comparable to the PA group. The use of vivid motor imagery may be an effective method for adapting to the illusory sensations and motion sickness symptoms produced by cross-coupled stimuli. For space-based AG applications, this technique may prove quite useful in retaining astronauts considered highly susceptible to motion sickness as it reduces the number of actual CCS required to attain adaptation.
Categorization of compensatory motions in transradial myoelectric prosthesis users.
Hussaini, Ali; Zinck, Arthur; Kyberd, Peter
2017-06-01
Prosthesis users perform various compensatory motions to accommodate for the loss of the hand and wrist as well as the reduced functionality of a prosthetic hand. Investigate different compensation strategies that are performed by prosthesis users. Comparative analysis. A total of 20 able-bodied subjects and 4 prosthesis users performed a set of bimanual activities. Movements of the trunk and head were recorded using a motion capture system and a digital video recorder. Clinical motion angles were calculated to assess the compensatory motions made by the prosthesis users. The video recording also assisted in visually identifying the compensations. Compensatory motions by the prosthesis users were evident in the tasks performed (slicing and stirring activities) as compared to the benchmark of able-bodied subjects. Compensations took the form of a measured increase in range of motion, an observed adoption of a new posture during task execution, and prepositioning of items in the workspace prior to initiating a given task. Compensatory motions were performed by prosthesis users during the selected tasks. These can be categorized into three different types of compensations. Clinical relevance Proper identification and classification of compensatory motions performed by prosthesis users into three distinct forms allows clinicians and researchers to accurately identify and quantify movement. It will assist in evaluating new prosthetic interventions by providing distinct terminology that is easily understood and can be shared between research institutions.
Hemmati, Nima; Abolhassani, Mohammad Djavad; Forghani, Arash
2008-01-01
Cervical range of motion (ROM) is a part of the dynamic component of spine evaluation and can be used as an indication of dysfunction in anatomical structures as well as a diagnostic aid in patients with neck pain. Studies indicate that movement coordination of axial segments such as head in dynamic state, disrupted in pathologic conditions. In recent years, a number of non-invasive instruments with varying degrees of accuracy and repeatability have been utilized to measure active or passive range of motion in asymptomatic adults. The aim of this investigation is to design and implement a new method by evidence based approach for estimating the level of defect in segment stability and improvement after treatment by measuring quality or quantity of movement among cervical segment. Transmitter sensors which have been mounted on body send ultrasonic burst signal periodically and from the delay time it takes for this burst to reach three other sensors which arranged on a T-shape Mechanical base, three dimensional position of the transmitter can be calculated. After sending 3D coordination data to a PC via USB port, a complex and elaborative Visual Basic software calculate the angular dispersion and acceleration for each segment separately. This software also calculates the stabilization parameters such as anchoring index (AI) and cross-correlation function (CCF) between head and trunk.
Model for the computation of self-motion in biological systems
NASA Technical Reports Server (NTRS)
Perrone, John A.
1992-01-01
A technique is presented by which direction- and speed-tuned cells, such as those commonly found in the middle temporal region of the primate brain, can be utilized to analyze the patterns of retinal image motion that are generated during observer movement through the environment. The developed model determines heading by finding the peak response in a population of detectors or neurons each tuned to a particular heading direction. It is suggested that a complex interaction of multiple cell networks is required for the solution of the self-motion problem in the primate brain.
A theoretical analysis of airplane longitudinal stability and control as affected by wind shear
NASA Technical Reports Server (NTRS)
Sherman, W. L.
1977-01-01
The longitudinal equations of motion with wind shear terms were used to analyze the stability and motions of a jet transport. A positive wind shear gives a decreasing head wind or changes a head wind into a tail wind. A negative wind shear gives a decreasing tail wind or changes a tail wind into a head wind. It was found that wind shear had very little effect on the short period mode and that negative wind shear, although it affected the phugoid, did not cause stability problems. On the other hand, it was found that positive wind shear can cause the phugoid to become aperiodic and unstable. In this case, a stability boundary for the phugoid was found that is valid for most aircraft at all flight speeds. Calculations of aircraft motions confirmed the results of the stability analysis. It was found that a flight path control automatic pilot and an airspeed control system provide good control in all types of wind shear. Appendixes give equations of motion that include the effects of downdrafts and updrafts and extend the longitudinal equations of motion for shear to six degrees of freedom.
Contribution of self-motion perception to acoustic target localization.
Pettorossi, V E; Brosch, M; Panichi, R; Botti, F; Grassi, S; Troiani, D
2005-05-01
The findings of this study suggest that acoustic spatial perception during head movement is achieved by the vestibular system, which is responsible for the correct dynamic of acoustic target pursuit. The ability to localize sounds in space during whole-body rotation relies on the auditory localization system, which recognizes the position of sound in a head-related frame, and on the sensory systems, namely the vestibular system, which perceive head and body movement. The aim of this study was to analyse the contribution of head motion cues to the spatial representation of acoustic targets in humans. Healthy subjects standing on a rotating platform in the dark were asked to pursue with a laser pointer an acoustic target which was horizontally rotated while the body was kept stationary or maintained stationary while the whole body was rotated. The contribution of head motion to the spatial acoustic representation could be inferred by comparing the gains and phases of the pursuit in the two experimental conditions when the frequency was varied. During acoustic target rotation there was a reduction in the gain and an increase in the phase lag, while during whole-body rotations the gain tended to increase and the phase remained constant. The different contributions of the vestibular and acoustic systems were confirmed by analysing the acoustic pursuit during asymmetric body rotation. In this particular condition, in which self-motion perception gradually diminished, an increasing delay in target pursuit was observed.
Fetsch, Christopher R; Wang, Sentao; Gu, Yong; Deangelis, Gregory C; Angelaki, Dora E
2007-01-17
Heading perception is a complex task that generally requires the integration of visual and vestibular cues. This sensory integration is complicated by the fact that these two modalities encode motion in distinct spatial reference frames (visual, eye-centered; vestibular, head-centered). Visual and vestibular heading signals converge in the primate dorsal subdivision of the medial superior temporal area (MSTd), a region thought to contribute to heading perception, but the reference frames of these signals remain unknown. We measured the heading tuning of MSTd neurons by presenting optic flow (visual condition), inertial motion (vestibular condition), or a congruent combination of both cues (combined condition). Static eye position was varied from trial to trial to determine the reference frame of tuning (eye-centered, head-centered, or intermediate). We found that tuning for optic flow was predominantly eye-centered, whereas tuning for inertial motion was intermediate but closer to head-centered. Reference frames in the two unimodal conditions were rarely matched in single neurons and uncorrelated across the population. Notably, reference frames in the combined condition varied as a function of the relative strength and spatial congruency of visual and vestibular tuning. This represents the first investigation of spatial reference frames in a naturalistic, multimodal condition in which cues may be integrated to improve perceptual performance. Our results compare favorably with the predictions of a recent neural network model that uses a recurrent architecture to perform optimal cue integration, suggesting that the brain could use a similar computational strategy to integrate sensory signals expressed in distinct frames of reference.
Yan, Chao-Gan; Cheung, Brian; Kelly, Clare; Colcombe, Stan; Craddock, R. Cameron; Di Martino, Adriana; Li, Qingyang; Zuo, Xi-Nian; Castellanos, F. Xavier; Milham, Michael P.
2014-01-01
Functional connectomics is one of the most rapidly expanding areas of neuroimaging research. Yet, concerns remain regarding the use of resting-state fMRI (R-fMRI) to characterize inter-individual variation in the functional connectome. In particular, recent findings that “micro” head movements can introduce artifactual inter-individual and group-related differences in R-fMRI metrics have raised concerns. Here, we first build on prior demonstrations of regional variation in the magnitude of framewise displacements associated with a given head movement, by providing a comprehensive voxel-based examination of the impact of motion on the BOLD signal (i.e., motion-BOLD relationships). Positive motion-BOLD relationships were detected in primary and supplementary motor areas, particularly in low motion datasets. Negative motion-BOLD relationships were most prominent in prefrontal regions, and expanded throughout the brain in high motion datasets (e.g., children). Scrubbing of volumes with FD > 0.2 effectively removed negative but not positive correlations; these findings suggest that positive relationships may reflect neural origins of motion while negative relationships are likely to originate from motion artifact. We also examined the ability of motion correction strategies to eliminate artifactual differences related to motion among individuals and between groups for a broad array of voxel-wise R-fMRI metrics. Residual relationships between motion and the examined R-fMRI metrics remained for all correction approaches, underscoring the need to covary motion effects at the group-level. Notably, global signal regression reduced relationships between motion and inter-individual differences in correlation-based R-fMRI metrics; Z-standardization (mean-centering and variance normalization) of subject-level maps for R-fMRI metrics prior to group-level analyses demonstrated similar advantages. Finally, our test-retest (TRT) analyses revealed significant motion effects on TRT reliability for R-fMRI metrics. Generally, motion compromised reliability of R-fMRI metrics, with the exception of those based on frequency characteristics – particularly, amplitude of low frequency fluctuations (ALFF). The implications of our findings for decision-making regarding the assessment and correction of motion are discussed, as are insights into potential differences among volume-based metrics of motion. PMID:23499792
Vestibular signals in primate cortex for self-motion perception.
Gu, Yong
2018-04-21
The vestibular peripheral organs in our inner ears detect transient motion of the head in everyday life. This information is sent to the central nervous system for automatic processes such as vestibulo-ocular reflexes, balance and postural control, and higher cognitive functions including perception of self-motion and spatial orientation. Recent neurophysiological studies have discovered a prominent vestibular network in the primate cerebral cortex. Many of the areas involved are multisensory: their neurons are modulated by both vestibular signals and visual optic flow, potentially facilitating more robust heading estimation through cue integration. Combining psychophysics, computation, physiological recording and causal manipulation techniques, recent work has addressed both the encoding and decoding of vestibular signals for self-motion perception. Copyright © 2018. Published by Elsevier Ltd.
Home-Based Computer Gaming in Vestibular Rehabilitation of Gaze and Balance Impairment.
Szturm, Tony; Reimer, Karen M; Hochman, Jordan
2015-06-01
Disease or damage of the vestibular sense organs cause a range of distressing symptoms and functional problems that could include loss of balance, gaze instability, disorientation, and dizziness. A novel computer-based rehabilitation system with therapeutic gaming application has been developed. This method allows different gaze and head movement exercises to be coupled to a wide range of inexpensive, commercial computer games. It can be used in standing, and thus graded balance demands using a sponge pad can be incorporated into the program. A case series pre- and postintervention study was conducted of nine adults diagnosed with peripheral vestibular dysfunction who received a 12-week home rehabilitation program. The feasibility and usability of the home computer-based therapeutic program were established. Study findings revealed that using head rotation to interact with computer games, when coupled to demanding balance conditions, resulted in significant improvements in standing balance, dynamic visual acuity, gaze control, and walking performance. Perception of dizziness as measured by the Dizziness Handicap Inventory also decreased significantly. These preliminary findings provide support that a low-cost home game-based exercise program is well suited to train standing balance and gaze control (with active and passive head motion).
Irregular head movement patterns in whiplash patients during a trajectory task.
Woodhouse, Astrid; Stavdahl, Øyvind; Vasseljen, Ottar
2010-03-01
Patients with whiplash associated disorders (WAD) have shown less accuracy in trajectory head motion compared to asymptomatic controls, which comply with clinical observations. The aim of this study was to investigate whether a trajectory head movement task can differ between WAD patients, chronic non-traumatic neck pain (CNP) patients and asymptomatic controls. Study groups included subjects with WAD (n = 35) with persistent neck pain after a car accident, CNP (n = 45), and asymptomatic controls (n = 48). Head motion was recorded from an unsupported standing position using a 3D Fastrak device. A laser pointer was attached to the head and by moving the head the subjects were asked to trace a figure of eight displayed on the wall at three different paces (slow, moderate and fast). The motion signal was decomposed into 1 Hz frequency bands and angular velocity (deg/s) within each frequency band was calculated. Significantly higher angular RMS velocity was found in the WAD group compared to the two other groups for the slow paced test (3-4 and 4-5 Hz frequency bands) and the moderate paced test (3-4 Hz frequency band) indicating irregular and uncoordinated movements. Angular RMS velocity was associated with pain and dizziness, but only with severe symptom levels. In conclusion, irregular head movements during a complex task were found in the WAD group, indicating altered central sensorimotor processing. The irregularities were found within frequency levels observable to clinicians.
Spatiotopic coding during dynamic head tilt
Turi, Marco; Burr, David C.
2016-01-01
Humans maintain a stable representation of the visual world effortlessly, despite constant movements of the eyes, head, and body, across multiple planes. Whereas visual stability in the face of saccadic eye movements has been intensely researched, fewer studies have investigated retinal image transformations induced by head movements, especially in the frontal plane. Unlike head rotations in the horizontal and sagittal planes, tilting the head in the frontal plane is only partially counteracted by torsional eye movements and consequently induces a distortion of the retinal image to which we seem to be completely oblivious. One possible mechanism aiding perceptual stability is an active reconstruction of a spatiotopic map of the visual world, anchored in allocentric coordinates. To explore this possibility, we measured the positional motion aftereffect (PMAE; the apparent change in position after adaptation to motion) with head tilts of ∼42° between adaptation and test (to dissociate retinal from allocentric coordinates). The aftereffect was shown to have both a retinotopic and spatiotopic component. When tested with unpatterned Gaussian blobs rather than sinusoidal grating stimuli, the retinotopic component was greatly reduced, whereas the spatiotopic component remained. The results suggest that perceptual stability may be maintained at least partially through mechanisms involving spatiotopic coding. NEW & NOTEWORTHY Given that spatiotopic coding could play a key role in maintaining visual stability, we look for evidence of spatiotopic coding after retinal image transformations caused by head tilt. To this end, we measure the strength of the positional motion aftereffect (PMAE; previously shown to be largely spatiotopic after saccades) after large head tilts. We find that, as with eye movements, the spatial selectivity of the PMAE has a large spatiotopic component after head rotation. PMID:27903636
Analysis of Methods to Excite Head-Tail Motion Within the Cornell Electron Storage Ring
NASA Astrophysics Data System (ADS)
Gendler, Naomi; Billing, Mike; Shanks, Jim
The main accelerator complex at Cornell consists of two rings around which electrons and positrons move: the synchrotron, where the particles are accelerated to 5 GeV, and the Storage Ring, where the particles circulate a ta Þxed energy, guided by quadrupole and dipole magnets, with a steady energy due to a sinusoidal voltage source. Keeping the beam stable in the Storage Ring is crucial for its lifetime. A long-lasting, invariable beam means more accurate experiments, as well as brighter, more focused X-rays for use in the Cornell High Energy Synchrotron Source (CHESS). The stability of the electron and positron beams in the Cornell Electron Storage Ring (CESR) is important for the development of accelerators and for usage of the beam in X-ray science and accelerator physics. Bunch oscillations tend to enlarge the beam's cross section, making it less stable. We believe that one such oscillation is ``head-tail motion,'' where the bunch rocks back and forth on a pivot located at the central particle. In this project, we write a simulation of the bunch that induces head-tail motion with a vertical driver. We also excite this motion physically in the storage ring, and observe a deÞnite head-tail signal. In the experiment, we saw a deÞnite persistence of the drive-damp signal within a small band around the head-tail frequency, indicating that the head-tail frequency is a natural vertical mode of the bunch that was being excited. The signal seen in the experiment matched the signal seen in the simulation to within an order of magnitude.
McNally, M P; Yontz, N; Chaudhari, A M
2014-08-01
While the golf swing is a complex whole body movement requiring coordination of all joints to achieve maximum ball velocity, the kinetic contribution of the lower extremities to club head velocity has not been quantified, despite the perception that the legs are a primary source of power during the swing. Mechanical power at the hips, knees, and ankles was estimated during the downswing phase of a full swing with a driver using a passive optical motion capture system and 2 force plates for adult males across a range of age and self-reported skill levels. Total work by the lower extremities was calculated by integrating the powers of all 6 joints over the downswing. Regression analyses showed that total lower extremity work was a strong predictor of club head velocity (R=0.63). Secondary analyses showed different relationships to club head velocity in lead and trail leg lower extremity joints, but none of these were as predictive of club head velocity as the total work performed by the lower extremities. These results provide quantitative evidence that the lower body's kinetic contribution may be an important factor in achieving greater club head velocity, contributing to greater driving distance and overall golf performance. © Georg Thieme Verlag KG Stuttgart · New York.
Subluxation of the femoral head in coxa plana.
Richards, B S; Coleman, S S
1987-12-01
Twenty-two patients who had severe coxa plana had closed reduction for lateral subluxation of the femoral head, as determined radiographically. All had painful limitation of motion of the hip that prevented proper positioning of the femoral head using a brace. The average age when the patients were first seen was eight years and six months. General anesthesia was required in order to obtain the reduction, and percutaneous tenotomy of the adductor longus was done whenever necessary. After the reduction, a Petrie cast was worn for several months. The length of follow-up averaged three years and eight months (range, two years to six years and eight months). Radiographic evaluation at the time of the last follow-up showed nine hips to be spherically congruent, twelve to be spherically congruent, and one to be incongruent. Thus, in 95 per cent of the hips, a congruent joint was obtained using this method of treatment. These results strongly support the concept that all treatment should be directed at containing the femoral head within the acetabulum during the clinically active phase of coxa plana.
Churchill, Nathan W.; Oder, Anita; Abdi, Hervé; Tam, Fred; Lee, Wayne; Thomas, Christopher; Ween, Jon E.; Graham, Simon J.; Strother, Stephen C.
2016-01-01
Subject-specific artifacts caused by head motion and physiological noise are major confounds in BOLD fMRI analyses. However, there is little consensus on the optimal choice of data preprocessing steps to minimize these effects. To evaluate the effects of various preprocessing strategies, we present a framework which comprises a combination of (1) nonparametric testing including reproducibility and prediction metrics of the data-driven NPAIRS framework (Strother et al. [2002]: NeuroImage 15:747–771), and (2) intersubject comparison of SPM effects, using DISTATIS (a three-way version of metric multidimensional scaling (Abdi et al. [2009]: NeuroImage 45:89–95). It is shown that the quality of brain activation maps may be significantly limited by sub-optimal choices of data preprocessing steps (or “pipeline”) in a clinical task-design, an fMRI adaptation of the widely used Trail-Making Test. The relative importance of motion correction, physiological noise correction, motion parameter regression, and temporal detrending were examined for fMRI data acquired in young, healthy adults. Analysis performance and the quality of activation maps were evaluated based on Penalized Discriminant Analysis (PDA). The relative importance of different preprocessing steps was assessed by (1) a nonparametric Friedman rank test for fixed sets of preprocessing steps, applied to all subjects; and (2) evaluating pipelines chosen specifically for each subject. Results demonstrate that preprocessing choices have significant, but subject-dependant effects, and that individually-optimized pipelines may significantly improve the reproducibility of fMRI results over fixed pipelines. This was demonstrated by the detection of a significant interaction with motion parameter regression and physiological noise correction, even though the range of subject head motion was small across the group (≪ 1 voxel). Optimizing pipelines on an individual-subject basis also revealed brain activation patterns either weak or absent under fixed pipelines, which has implications for the overall interpretation of fMRI data, and the relative importance of preprocessing methods. PMID:21455942
Chen, Hongwei; Wang, Ziyang; Shang, Yongjun
2018-06-01
To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values <0.001 for both unipolar and bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.
Sasaki, Ryo; Angelaki, Dora E; DeAngelis, Gregory C
2017-11-15
We use visual image motion to judge the movement of objects, as well as our own movements through the environment. Generally, image motion components caused by object motion and self-motion are confounded in the retinal image. Thus, to estimate heading, the brain would ideally marginalize out the effects of object motion (or vice versa), but little is known about how this is accomplished neurally. Behavioral studies suggest that vestibular signals play a role in dissociating object motion and self-motion, and recent computational work suggests that a linear decoder can approximate marginalization by taking advantage of diverse multisensory representations. By measuring responses of MSTd neurons in two male rhesus monkeys and by applying a recently-developed method to approximate marginalization by linear population decoding, we tested the hypothesis that vestibular signals help to dissociate self-motion and object motion. We show that vestibular signals stabilize tuning for heading in neurons with congruent visual and vestibular heading preferences, whereas they stabilize tuning for object motion in neurons with discrepant preferences. Thus, vestibular signals enhance the separability of joint tuning for object motion and self-motion. We further show that a linear decoder, designed to approximate marginalization, allows the population to represent either self-motion or object motion with good accuracy. Decoder weights are broadly consistent with a readout strategy, suggested by recent computational work, in which responses are decoded according to the vestibular preferences of multisensory neurons. These results demonstrate, at both single neuron and population levels, that vestibular signals help to dissociate self-motion and object motion. SIGNIFICANCE STATEMENT The brain often needs to estimate one property of a changing environment while ignoring others. This can be difficult because multiple properties of the environment may be confounded in sensory signals. The brain can solve this problem by marginalizing over irrelevant properties to estimate the property-of-interest. We explore this problem in the context of self-motion and object motion, which are inherently confounded in the retinal image. We examine how diversity in a population of multisensory neurons may be exploited to decode self-motion and object motion from the population activity of neurons in macaque area MSTd. Copyright © 2017 the authors 0270-6474/17/3711204-16$15.00/0.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paulson, Eric S.; Bradley, Julie A.; Wang Dian
2011-04-15
Purpose: Intensity-modulated radiation therapy (IMRT) is a promising treatment modality for patients with head and neck cancer (HNC). The dose distributions from IMRT are static and, thus, are unable to account for variations and/or uncertainties in the relationship between the patient (region being treated) and the beam. Organ motion comprises one such source of this uncertainty, introduced by physiological variation in the position, size, and shape of organs during treatment. In the head and neck, the predominant source of this variation arises from deglutition (swallowing). The purpose of this study was to investigate whether cinematographic MRI (cine MRI) could bemore » used to determine asymmetric (nonuniform) internal margin (IM) components of tumor planning target volumes based on the actual deglutition-induced tumor displacement. Methods: Five head and neck cancer patients were set up in treatment position on a 3 T MRI scanner. Two time series of single-slice, sagittal, cine images were acquired using a 2D FLASH sequence. The first time series was a 12.8 min scan designed to capture the frequency and duration of deglutition in the treatment position. The second time series was a short, 15 s scan designed to capture the displacement of deglutition in the treatment position. Deglutition frequency and mean swallow duration were estimated from the long time series acquisition. Swallowing and resting (nonswallowing) events were identified on the short time series acquisition and displacement was estimated based on contours of gross tumor volume (GTV) generated at each time point of a particular event. A simple linear relationship was derived to estimate 1D asymmetric IMs in the presence of resting- and deglutition-induced displacement. Results: Deglutition was nonperiodic, with frequency and duration ranging from 2.89-24.18 mHz and from 3.86 to 6.10 s, respectively. The deglutition frequency and mean duration were found to vary among patients. Deglutition-induced maximal GTV displacements ranged from 0.00 to 28.36 mm with mean and standard deviation of 4.72{+-}3.18, 3.70{+-}2.81, 2.75{+-}5.24, and 10.40{+-}10.76 mm in the A, P, I, and S directions, respectively. Resting-induced maximal GTV displacement ranged from 0.00 to 5.59 mm with mean and standard deviation of 3.01{+-}1.80, 1.25{+-}1.10, 3.23+2.20, and 2.47{+-}1.11 mm in the A, P, I, and S directions, respectively. For both resting and swallowing states, displacement along the S-I direction dominated displacement along the A-P direction. The calculated IMs were dependent on deglutition frequency, ranging from 3.28-4.37 mm for the lowest deglutition frequency patient to 3.76-6.43 mm for the highest deglutition frequency patient. A statistically significant difference was detected between IMs calculated for P and S directions (p=0.0018). Conclusions: Cine MRI is able to capture tumor motion during deglutition. Swallowing events can be demarcated by MR signal intensity changes caused by anatomy containing fully relaxed spins that move medially into the imaging plane during deglutition. Deglutition is nonperiodic and results in dynamic changes in the tumor position. Deglutition-induced displacements are larger and more variable than resting displacements. The nonzero mean maximum resting displacement indicates that some tumor motion occurs even when the patient is not swallowing. Asymmetric IMs, derived from deglutition frequency, duration, and directional displacement, should be employed to account for tumor motion in HNC RT.« less
Shimizu, Takamasa; Omokawa, Shohei; del Piñal, Francisco; Shigematsu, Koji; Moritomo, Hisao; Tanaka, Yasuhito
2015-12-01
To examine short-term clinical results of arthroscopic partial resection for type Ia avascular necrosis of the capitate. Patients who underwent arthroscopic treatment for type 1a avascular necrosis of the capitate with at least 1-year follow-up were identified through a retrospective chart review. The necrotic capitate head was arthroscopically resected with removal of the lunate facet and preservation of the scaphoid and hamate facets. Wrist range of motion, grip strength, and radiographic parameters--carpal height ratio, radioscaphoid angle, and radiolunate angle-were determined before surgery and at the latest follow-up. Patients completed a visual analog scale for pain; Disabilities of the Arm, Shoulder, and Hand measure; and the Patient-Rated Wrist Evaluation score before surgery and at the latest follow-up. Five patients (1 male, 4 females) with a mean age of 34 years (range, 16-49 years) and a mean follow-up duration of 20 months (range, 12-36 months) were identified during the chart review. All were type Ia (Milliez classification). Arthroscopy revealed fibrillation or softening with cartilage detachment at the lunate facet of the capitate head and an intact articular surface at the scaphoid and hamate facet. At the latest follow-up, the mean wrist flexion-extension was 123° (vs 81° before surgery) and grip strength was 74% (vs 37% before surgery). The visual analog scale score for pain; the Disabilities of the Arm, Shoulder, and Hand score; and the Patient-Rated Wrist Evaluation score before surgery showed a significant improvement following treatment. Radiographic parameters did not significantly change at the final follow-up, although the proximal carpal row trended toward flexion. Arthroscopic partial resection of the capitate head was an acceptable treatment for type Ia avascular necrosis of the capitate. It provided adequate pain relief and improved the range of wrist motion and grip strength during short-term follow-up. Therapeutic IV. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Admiralty Inlet Advanced Turbulence Measurements: June 2014
Kilcher, Levi
2014-06-30
This data is from measurements at Admiralty Head, in Admiralty Inlet (Puget Sound) in June of 2014. The measurements were made using Inertial Motion Unit (IMU) equipped ADVs mounted on Tidal Turbulence Mooring's (TTMs). The TTM positions the ADV head above the seafloor to make mid-depth turbulence measurements. The inertial measurements from the IMU allows for removal of mooring motion in post processing. The mooring motion has been removed from the stream-wise and vertical velocity signals (u, w). The lateral (v) velocity has some 'persistent motion contamination' due to mooring sway. Each ttm was deployed with two ADVs. The 'top' ADV head was positioned 0.5m above the 'bottom' ADV head. The TTMs were placed in 58m of water. The position of the TTMs were: ttm01 : (48.1525, -122.6867) ttm01b : (48.15256666, -122.68678333) ttm02b : (48.152783333, -122.686316666) Deployments TTM01b and TTM02b occurred simultaneously and were spaced approximately 50m apart in the cross-stream direction. Units ----- - Velocity data (_u, urot, uacc) is in m/s. - Acceleration (Accel) data is in m/s^2. - Angular rate (AngRt) data is in rad/s. - The components of all vectors are in 'ENU' orientation. That is, the first index is True East, the second is True North, and the third is Up (vertical). - All other quantities are in the units defined in the Nortek Manual. Motion correction and rotation into the ENU earth reference frame was performed using the Python-based open source DOLfYN library (http://lkilcher.github.io/dolfyn/). Details on motion correction can be found there. Additional details on TTM measurements at this site can be found in the included Marine Energy Technology Symposium paper.
NASA Technical Reports Server (NTRS)
Teixeira, R. A.; Lackner, J. R.
1979-01-01
An experimental study was conducted on seven normal subjects to evaluate the effectiveness of passive head movements in suppressing the optokinetically-induced illusory self-rotation. Visual simulation was provided by a servo-controlled optokinetic drum. Each subject participated in two experimental sessions. In one condition, the subject's head remained stationary while he gazed passively at a moving stripe pattern. In the other, he gazed passively and relaxed his neck muscles while his head was rotated from side to side. It appears that suppression of optokinetically-induced illusory self-rotation with passive head movements results from the operation of a spatial constancy mechanism interrelating visual, vestibular, and kinesthetic information on ongoing body orientation. The results support the view that optokinetic 'motion sickness' is related, at least in part, to an oculomotor disturbance rather than a visually triggered disturbance of specifically vestibular etiology.
McArthur, Kimberly L; Dickman, J David
2011-04-01
Vestibular responses play an important role in maintaining gaze and posture stability during rotational motion. Previous studies suggest that these responses are state dependent, their expression varying with the environmental and locomotor conditions of the animal. In this study, we simulated an ethologically relevant state in the laboratory to study state-dependent vestibular responses in birds. We used frontal airflow to simulate gliding flight and measured pigeons' eye, head, and tail responses to rotational motion in darkness, under both head-fixed and head-free conditions. We show that both eye and head response gains are significantly higher during flight, thus enhancing gaze and head-in-space stability. We also characterize state-specific tail responses to pitch and roll rotation that would help to maintain body-in-space orientation during flight. These results demonstrate that vestibular sensorimotor processing is not fixed but depends instead on the animal's behavioral state.
State-dependent sensorimotor processing: gaze and posture stability during simulated flight in birds
McArthur, Kimberly L.
2011-01-01
Vestibular responses play an important role in maintaining gaze and posture stability during rotational motion. Previous studies suggest that these responses are state dependent, their expression varying with the environmental and locomotor conditions of the animal. In this study, we simulated an ethologically relevant state in the laboratory to study state-dependent vestibular responses in birds. We used frontal airflow to simulate gliding flight and measured pigeons′ eye, head, and tail responses to rotational motion in darkness, under both head-fixed and head-free conditions. We show that both eye and head response gains are significantly higher during flight, thus enhancing gaze and head-in-space stability. We also characterize state-specific tail responses to pitch and roll rotation that would help to maintain body-in-space orientation during flight. These results demonstrate that vestibular sensorimotor processing is not fixed but depends instead on the animal's behavioral state. PMID:21307332
The role of passive avian head stabilization in flapping flight
Pete, Ashley E.; Kress, Daniel; Dimitrov, Marina A.; Lentink, David
2015-01-01
Birds improve vision by stabilizing head position relative to their surroundings, while their body is forced up and down during flapping flight. Stabilization is facilitated by compensatory motion of the sophisticated avian head–neck system. While relative head motion has been studied in stationary and walking birds, little is known about how birds accomplish head stabilization during flapping flight. To unravel this, we approximate the avian neck with a linear mass–spring–damper system for vertical displacements, analogous to proven head stabilization models for walking humans. We corroborate the model's dimensionless natural frequency and damping ratios from high-speed video recordings of whooper swans (Cygnus cygnus) flying over a lake. The data show that flap-induced body oscillations can be passively attenuated through the neck. We find that the passive model robustly attenuates large body oscillations, even in response to head mass and gust perturbations. Our proof of principle shows that bird-inspired drones with flapping wings could record better images with a swan-inspired passive camera suspension. PMID:26311316
Artificial gravity: head movements during short-radius centrifugation
NASA Technical Reports Server (NTRS)
Young, L. R.; Hecht, H.; Lyne, L. E.; Sienko, K. H.; Cheung, C. C.; Kavelaars, J.
2001-01-01
Short-radius centrifugation is a potential countermeasure to long-term weightlessness. Unfortunately, head movements in a rotating environment induce serious discomfort, non-compensatory vestibulo-ocular reflexes, and subjective illusions of body tilt. In two experiments we investigated the effects of pitch and yaw head movements in participants placed supine on a rotating bed with their head at the center of rotation, feet at the rim. The vast majority of participants experienced motion sickness, inappropriate vertical nystagmus and illusory tilt and roll as predicted by a semicircular canal model. However, a small but significant number of the 28 participants experienced tilt in the predicted plane but in the opposite direction. Heart rate was elevated following one-second duration head turns. Significant adaptation occurred following a series of head turns in the light. Vertical nystagmus, motion sickness and illusory tilt all decreased with adaptation. Consequences for artificial gravity produced by short-radius centrifuges as a countermeasure are discussed. Grant numbers: NCC 9-58. c 2001. Elsevier Science Ltd. All rights reserved.
Correction of patient motion in cone-beam CT using 3D-2D registration
NASA Astrophysics Data System (ADS)
Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.
2017-12-01
Cone-beam CT (CBCT) is increasingly common in guidance of interventional procedures, but can be subject to artifacts arising from patient motion during fairly long (~5-60 s) scan times. We present a fiducial-free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in the intrinsic and extrinsic parameters of geometric calibration. The 3D-2D registration process registers each projection to a prior 3D image by maximizing gradient orientation using the covariance matrix adaptation-evolution strategy optimizer. The resulting rigid transforms are applied to the system projection matrices, and a 3D image is reconstructed via model-based iterative reconstruction. Phantom experiments were conducted using a Zeego robotic C-arm to image a head phantom undergoing 5-15 cm translations and 5-15° rotations. To further test the algorithm, clinical images were acquired with a CBCT head scanner in which long scan times were susceptible to significant patient motion. CBCT images were reconstructed using a penalized likelihood objective function. For phantom studies the structural similarity (SSIM) between motion-free and motion-corrected images was >0.995, with significant improvement (p < 0.001) compared to the SSIM values of uncorrected images. Additionally, motion-corrected images exhibited a point-spread function with full-width at half maximum comparable to that of the motion-free reference image. Qualitative comparison of the motion-corrupted and motion-corrected clinical images demonstrated a significant improvement in image quality after motion correction. This indicates that the 3D-2D registration method could provide a useful approach to motion artifact correction under assumptions of local rigidity, as in the head, pelvis, and extremities. The method is highly parallelizable, and the automatic correction of residual geometric calibration errors provides added benefit that could be valuable in routine use.
NASA Technical Reports Server (NTRS)
Dimeff, J.; Rositano, S.; Taylor, R. C.
1977-01-01
Mandibular motion along three axes is measured by three motion transducers on floating yoke that rests against mandible. System includes electronics to provide variety of outputs for data display and processing. Head frame is strapped to test subject's skull to provide fixed point of reference for transducers.
Sensory and motor properties of the cerebellar uvula and modulus
NASA Technical Reports Server (NTRS)
Robinson, F. R.
1985-01-01
The uvula and nodulus (vermal lobules 9 and 10) of the vestibulocerebellum are implicated by behavioral evidence in the control of eye and head movements and in the production of motion sickness. The uvula and nodulus could play a role in these functions through known output pathways. Purkinje cells in both structures project via the fastigial and vestibular nuceli to the ventral horn of the cervical spin cord, to oculomotor neurons, and to the emetic region of the reticular formation (ablation of which abolishes susceptability to motion sickness). Uvula and nodulus Purkinje cells will be analyzed in cats trained to make controlled head movements. The activity of these neurons is expected to modulate well during head and/or eye movements because the uvula and nodulus receive heavy projections from sources of visual, vestibular and neck proprioceptive information. How neuron activity contributes to movement and how different sensory inputs converge to influence this contribution may be determined by characterizing movement related properties of these neurons. A population of neurons that modulates powerfully to the conflict between different head movement signals that can cause motion sickness may be identified.
Carriot, Jerome; Brooks, Jessica X.
2013-01-01
The ability to keep track of where we are going as we navigate through our environment requires knowledge of our ongoing location and orientation. In response to passively applied motion, the otolith organs of the vestibular system encode changes in the velocity and direction of linear self-motion (i.e., heading). When self-motion is voluntarily generated, proprioceptive and motor efference copy information is also available to contribute to the brain's internal representation of current heading direction and speed. However to date, how the brain integrates these extra-vestibular cues with otolith signals during active linear self-motion remains unknown. Here, to address this question, we compared the responses of macaque vestibular neurons during active and passive translations. Single-unit recordings were made from a subgroup of neurons at the first central stage of sensory processing in the vestibular pathways involved in postural control and the computation of self-motion perception. Neurons responded far less robustly to otolith stimulation during self-generated than passive head translations. Yet, the mechanism underlying the marked cancellation of otolith signals did not affect other characteristics of neuronal responses (i.e., baseline firing rate, tuning ratio, orientation of maximal sensitivity vector). Transiently applied perturbations during active motion further established that an otolith cancellation signal was only gated in conditions where proprioceptive sensory feedback matched the motor-based expectation. Together our results have important implications for understanding the brain's ability to ensure accurate postural and motor control, as well as perceptual stability, during active self-motion. PMID:24336720
Visual-Vestibular Conflict Detection Depends on Fixation.
Garzorz, Isabelle T; MacNeilage, Paul R
2017-09-25
Visual and vestibular signals are the primary sources of sensory information for self-motion. Conflict among these signals can be seriously debilitating, resulting in vertigo [1], inappropriate postural responses [2], and motion, simulator, or cyber sickness [3-8]. Despite this significance, the mechanisms mediating conflict detection are poorly understood. Here we model conflict detection simply as crossmodal discrimination with benchmark performance limited by variabilities of the signals being compared. In a series of psychophysical experiments conducted in a virtual reality motion simulator, we measure these variabilities and assess conflict detection relative to this benchmark. We also examine the impact of eye movements on visual-vestibular conflict detection. In one condition, observers fixate a point that is stationary in the simulated visual environment by rotating the eyes opposite head rotation, thereby nulling retinal image motion. In another condition, eye movement is artificially minimized via fixation of a head-fixed fixation point, thereby maximizing retinal image motion. Visual-vestibular integration performance is also measured, similar to previous studies [9-12]. We observe that there is a tradeoff between integration and conflict detection that is mediated by eye movements. Minimizing eye movements by fixating a head-fixed target leads to optimal integration but highly impaired conflict detection. Minimizing retinal motion by fixating a scene-fixed target improves conflict detection at the cost of impaired integration performance. The common tendency to fixate scene-fixed targets during self-motion [13] may indicate that conflict detection is typically a higher priority than the increase in precision of self-motion estimation that is obtained through integration. Copyright © 2017 Elsevier Ltd. All rights reserved.
Scale Changes Provide an Alternative Cue For the Discrimination of Heading, But Not Object Motion
Calabro, Finnegan J.; Vaina, Lucia Maria
2016-01-01
Background Understanding the dynamics of our surrounding environments is a task usually attributed to the detection of motion based on changes in luminance across space. Yet a number of other cues, both dynamic and static, have been shown to provide useful information about how we are moving and how objects around us move. One such cue, based on changes in spatial frequency, or scale, over time has been shown to be useful in conveying motion in depth even in the absence of a coherent, motion-defined flow field (optic flow). Material/Methods 16 right handed healthy observers (ages 18–28) participated in the behavioral experiments described in this study. Using analytical behavioral methods we investigate the functional specificity of this cue by measuring the ability of observers to perform tasks of heading (direction of self-motion) and 3D trajectory discrimination on the basis of scale changes and optic flow. Results Statistical analyses of performance on the test-experiments in comparison to the control experiments suggests that while scale changes may be involved in the detection of heading, they are not correctly integrated with translational motion and, thus, do not provide a correct discrimination of 3D object trajectories. Conclusions These results have the important implication for the type of visual guided navigation that can be done by an observer blind to optic flow. Scale change is an important alternative cue for self-motion. PMID:27231114
Scale Changes Provide an Alternative Cue For the Discrimination of Heading, But Not Object Motion.
Calabro, Finnegan J; Vaina, Lucia Maria
2016-05-27
BACKGROUND Understanding the dynamics of our surrounding environments is a task usually attributed to the detection of motion based on changes in luminance across space. Yet a number of other cues, both dynamic and static, have been shown to provide useful information about how we are moving and how objects around us move. One such cue, based on changes in spatial frequency, or scale, over time has been shown to be useful in conveying motion in depth even in the absence of a coherent, motion-defined flow field (optic flow). MATERIAL AND METHODS 16 right handed healthy observers (ages 18-28) participated in the behavioral experiments described in this study. Using analytical behavioral methods we investigate the functional specificity of this cue by measuring the ability of observers to perform tasks of heading (direction of self-motion) and 3D trajectory discrimination on the basis of scale changes and optic flow. RESULTS Statistical analyses of performance on the test-experiments in comparison to the control experiments suggests that while scale changes may be involved in the detection of heading, they are not correctly integrated with translational motion and, thus, do not provide a correct discrimination of 3D object trajectories. CONCLUSIONS These results have the important implication for the type of visual guided navigation that can be done by an observer blind to optic flow. Scale change is an important alternative cue for self-motion.
Leung, Lai Yee; Larimore, Zachary; Holmes, Larry; Cartagena, Casandra; Mountney, Andrea; Deng-Bryant, Ying; Schmid, Kara; Shear, Deborah; Tortella, Frank
2014-08-01
The WRAIR projectile concussive impact (PCI) model was developed for preclinical study of concussion. It represents a truly non-invasive closed-head injury caused by a blunt impact. The original design, however, has several drawbacks that limit the manipulation of injury parameters. The present study describes engineering advancements made to the PCI injury model including helmet material testing, projectile impact energy/head kinematics and impact location. Material testing indicated that among the tested materials, 'fiber-glass/carbon' had the lowest elastic modulus and yield stress for providing an relative high percentage of load transfer from the projectile impact, resulting in significant hippocampal astrocyte activation. Impact energy testing of small projectiles, ranging in shape and size, showed the steel sphere produced the highest impact energy and the most consistent impact characteristics. Additional tests confirmed the steel sphere produced linear and rotational motions on the rat's head while remaining within a range that meets the criteria for mTBI. Finally, impact location testing results showed that PCI targeted at the temporoparietal surface of the rat head produced the most prominent gait abnormalities. Using the parameters defined above, pilot studies were conducted to provide initial validation of the PCI model demonstrating quantifiable and significant increases in righting reflex recovery time, axonal damage and astrocyte activation following single and multiple concussions.
NASA Astrophysics Data System (ADS)
Rengganis, Y. A.; Safrodin, M.; Sukaridhoto, S.
2018-01-01
Virtual Reality Laboratory (VR Lab) is an innovation for conventional learning media which show us whole learning process in laboratory. There are many tools and materials are needed by user for doing practical in it, so user could feel new learning atmosphere by using this innovation. Nowadays, technologies more sophisticated than before. So it would carry in education and it will be more effective, efficient. The Supported technologies are needed us for making VR Lab such as head mounted display device and hand motion gesture device. The integration among them will be used us for making this research. Head mounted display device for viewing 3D environment of virtual reality laboratory. Hand motion gesture device for catching user real hand and it will be visualized in virtual reality laboratory. Virtual Reality will show us, if using the newest technologies in learning process it could make more interesting and easy to understand.
The six degrees of freedom motion of the human head, spine, and pelvis in a frontal impact.
Lopez-Valdes, F J; Riley, P O; Lessley, D J; Arbogast, K B; Seacrist, T; Balasubramanian, S; Maltese, M; Kent, R
2014-01-01
The goal of this study is to characterize the in situ 6-degree-of-freedom kinematics of the head, 3 vertebrae (T1, T8, and L2), and the pelvis in a 40 km/h frontal impact. Three postmortem human surrogates (PMHS) were exposed to a deceleration of 15 g over 125 ms and the motion of selected anatomical structures (head, T1, T8, L2, and pelvis) was tracked at 1000 Hz using an optoelectric stereophotogrammetric system. Displacements of the analyzed structures are reported in the sagittal and the transverse planes. Rotations of the structures are described using the finite helical axis of the motion. Anterior displacements were 530.5 ± 39.4 mm (head), 434.7 ± 20.0 mm (T1), 353.3 ± 29.6 mm (T8), 219.9 ± 19.3 mm (L2), and 78.9 ± 22.1 mm (pelvis). The ratio between peak anterior and lateral displacement was up to 19 percent (T1) and 26 percent (head). Magnitudes of the rotation of the head (69.9 ± 1.5°), lumbar (66.5 ± 9.1°), and pelvis (63.8 ± 11.8°) were greater than that of the thoracic vertebrae (T1: 49.1 ± 7.8°; T8: 47.7 ± 6.3°). Thoracic vertebrae exhibited a complex rotation behavior caused by the asymmetric loading of the shoulder belt. Rotation of the lumbar vertebra and pelvis occurred primarily within the sagittal plane (flexion). Despite the predominance of the sagittal motion of the occupant in a pure (12 o'clock) frontal impact, the asymmetry of belt loading induced other relevant displacements and rotations of the head and thoracic spine. Attempts to model occupant kinematics in a frontal impact should consider these results to biofidelically describe the interaction of the torso with the belt.
NASA Astrophysics Data System (ADS)
Miranda, Alan; Staelens, Steven; Stroobants, Sigrid; Verhaeghe, Jeroen
2017-03-01
Preclinical positron emission tomography (PET) imaging in small animals is generally performed under anesthesia to immobilize the animal during scanning. More recently, for rat brain PET studies, methods to perform scans of unrestrained awake rats are being developed in order to avoid the unwanted effects of anesthesia on the brain response. Here, we investigate the use of a projected structure stereo camera to track the motion of the rat head during the PET scan. The motion information is then used to correct the PET data. The stereo camera calculates a 3D point cloud representation of the scene and the tracking is performed by point cloud matching using the iterative closest point algorithm. The main advantage of the proposed motion tracking is that no intervention, e.g. for marker attachment, is needed. A manually moved microDerenzo phantom experiment and 3 awake rat [18F]FDG experiments were performed to evaluate the proposed tracking method. The tracking accuracy was 0.33 mm rms. After motion correction image reconstruction, the microDerenzo phantom was recovered albeit with some loss of resolution. The reconstructed FWHM of the 2.5 and 3 mm rods increased with 0.94 and 0.51 mm respectively in comparison with the motion-free case. In the rat experiments, the average tracking success rate was 64.7%. The correlation of relative brain regional [18F]FDG uptake between the anesthesia and awake scan reconstructions was increased from on average 0.291 (not significant) before correction to 0.909 (p < 0.0001) after motion correction. Markerless motion tracking using structured light can be successfully used for tracking of the rat head for motion correction in awake rat PET scans.
Destabilizing effects of visual environment motions simulating eye movements or head movements
NASA Technical Reports Server (NTRS)
White, Keith D.; Shuman, D.; Krantz, J. H.; Woods, C. B.; Kuntz, L. A.
1991-01-01
In the present paper, we explore effects on the human of exposure to a visual virtual environment which has been enslaved to simulate the human user's head movements or eye movements. Specifically, we have studied the capacity of our experimental subjects to maintain stable spatial orientation in the context of moving their entire visible surroundings by using the parameters of the subjects' natural movements. Our index of the subjects' spatial orientation was the extent of involuntary sways of the body while attempting to stand still, as measured by translations and rotations of the head. We also observed, informally, their symptoms of motion sickness.
Measurement of six-degree-of-freedom planar motions by using a multiprobe surface encoder
NASA Astrophysics Data System (ADS)
Li, Xinghui; Shimizu, Yuki; Ito, Takeshi; Cai, Yindi; Ito, So; Gao, Wei
2014-12-01
A multiprobe surface encoder for optical metrology of six-degree-of-freedom (six-DOF) planar motions is presented. The surface encoder is composed of an XY planar scale grating with identical microstructures in X- and Y-axes and an optical sensor head. In the optical sensor head, three paralleled laser beams were used as laser probes. After being divided by a beam splitter, the three laser probes were projected onto the scale grating and a reference grating with identical microstructures, respectively. For each probe, the first-order positive and negative diffraction beams along the X- and Y-directions from the scale grating and from the reference grating superimposed with each other and four pieces of interference signals were generated. Three-DOF translational motions of the scale grating Δx, Δy, and Δz can be obtained simultaneously from the interference signals of each probe. Three-DOF angular error motions θX, θY, and θZ can also be calculated simultaneously from differences of displacement output variations and the geometric relationship among the three probes. A prototype optical sensor head was designed, constructed, and evaluated. Experimental results verified that this surface encoder could provide measurement resolutions of subnanometer and better than 0.1 arc sec for three-DOF translational motions and three-DOF angular error motions, respectively.
Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia
2016-07-01
The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians. This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers. Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s. The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.
Sato, Nahoko; Nunome, Hiroyuki; Ikegami, Yasuo
2015-02-01
In hip-hop dance contests, a procedure for evaluating performances has not been clearly defined, and objective criteria for evaluation are necessary. It is assumed that most hip-hop dance techniques have common motion characteristics by which judges determine the dancer's skill level. This study aimed to extract motion characteristics that may be linked to higher evaluations by judges. Ten expert and 12 nonexpert dancers performed basic rhythmic movements at a rate of 100 beats per minute. Their movements were captured using a motion capture system, and eight judges evaluated the performances. Four kinematic parameters, including the amplitude of the body motions and the phase delay, which indicates the phase difference between two joint angles, were calculated. The two groups showed no significant differences in terms of the amplitudes of the body motions. In contrast, the phase delay between the head motion and the other body parts' motions of expert dancers who received higher scores from the judges, which was approximately a quarter cycle, produced a loop-shaped motion of the head. It is suggested that this slight phase delay was related to the judges' evaluations and that these findings may help in constructing an objective evaluation system.
Motion sickness susceptibility in parabolic flight and velocity storage activity
NASA Technical Reports Server (NTRS)
Dizio, Paul; Lackner, James R.
1991-01-01
In parabolic flight experiments, postrotary nystagmus is as found to be differentially suppressed in free fall (G) and in a high gravitoinertial force (1.8 G) background relative to 1 G. In addition, the influence of postrotary head movements on nystagmus suppression was found to be contingent on G-dependency of the velocity storage and dumping mechanisms. Here, susceptibility to motion sickness during head movements in 0 G and 1.8 G was rank-correlated with the following: (1) the decay time constant of the slow phase velocity of postrotary nystagmus under 1 G, no head movement, baseline conditions, (2) the extent of time constant reduction elicited in 0 G and 1.8 G; (3) the extent of time constant reduction elicited by head tilts in 1 G; and (4) changes in the extent of time constants reduction in 0 G and 1.8 G over repeated tests. Susceptibility was significantly correlated with the extent to which a head movement reduced the time constant in 1 G, was weakly correlated with the baseline time constant, but was not correlated with the extent of reduction in 0 G or 1.8 G. This pattern suggests a link between mechanisms evoking symptoms of space motion sickness and the mechanisms of velocity storage and dumping. Experimental means of evaluating this link are described.
Yang, Yun; Liu, Sheng; Chowdhury, Syed A.; DeAngelis, Gregory C.; Angelaki, Dora E.
2012-01-01
Many neurons in the dorsal medial superior temporal (MSTd) and ventral intraparietal (VIP) areas of the macaque brain are multisensory, responding to both optic flow and vestibular cues to self-motion. The heading tuning of visual and vestibular responses can be either congruent or opposite, but only congruent cells have been implicated in cue integration for heading perception. Because of the geometric properties of motion parallax, however, both congruent and opposite cells could be involved in coding self-motion when observers fixate a world-fixed target during translation, if congruent cells prefer near disparities and opposite cells prefer far disparities. We characterized the binocular disparity selectivity and heading tuning of MSTd and VIP cells using random-dot stimuli. Most (70%) MSTd neurons were disparity-selective with monotonic tuning, and there was no consistent relationship between depth preference and congruency of visual and vestibular heading tuning. One-third of disparity-selective MSTd cells reversed their depth preference for opposite directions of motion (direction-dependent disparity tuning, DDD), but most of these cells were unisensory with no tuning for vestibular stimuli. Inconsistent with previous reports, the direction preferences of most DDD neurons do not reverse with disparity. By comparison to MSTd, VIP contains fewer disparity-selective neurons (41%) and very few DDD cells. On average, VIP neurons also preferred higher speeds and nearer disparities than MSTd cells. Our findings are inconsistent with the hypothesis that visual/vestibular congruency is linked to depth preference, and also suggest that DDD cells are not involved in multisensory integration for heading perception. PMID:22159105
Hallquist, Michael N.; Hwang, Kai; Luna, Beatriz
2013-01-01
Recent resting-state functional connectivity fMRI (RS-fcMRI) research has demonstrated that head motion during fMRI acquisition systematically influences connectivity estimates despite bandpass filtering and nuisance regression, which are intended to reduce such nuisance variability. We provide evidence that the effects of head motion and other nuisance signals are poorly controlled when the fMRI time series are bandpass-filtered but the regressors are unfiltered, resulting in the inadvertent reintroduction of nuisance-related variation into frequencies previously suppressed by the bandpass filter, as well as suboptimal correction for noise signals in the frequencies of interest. This is important because many RS-fcMRI studies, including some focusing on motion-related artifacts, have applied this approach. In two cohorts of individuals (n = 117 and 22) who completed resting-state fMRI scans, we found that the bandpass-regress approach consistently overestimated functional connectivity across the brain, typically on the order of r = .10 – .35, relative to a simultaneous bandpass filtering and nuisance regression approach. Inflated correlations under the bandpass-regress approach were associated with head motion and cardiac artifacts. Furthermore, distance-related differences in the association of head motion and connectivity estimates were much weaker for the simultaneous filtering approach. We recommend that future RS-fcMRI studies ensure that the frequencies of nuisance regressors and fMRI data match prior to nuisance regression, and we advocate a simultaneous bandpass filtering and nuisance regression strategy that better controls nuisance-related variability. PMID:23747457
Effect of eye position during human visual-vestibular integration of heading perception.
Crane, Benjamin T
2017-09-01
Visual and inertial stimuli provide heading discrimination cues. Integration of these multisensory stimuli has been demonstrated to depend on their relative reliability. However, the reference frame of visual stimuli is eye centered while inertia is head centered, and it remains unclear how these are reconciled with combined stimuli. Seven human subjects completed a heading discrimination task consisting of a 2-s translation with a peak velocity of 16 cm/s. Eye position was varied between 0° and ±25° left/right. Experiments were done with inertial motion, visual motion, or a combined visual-inertial motion. Visual motion coherence varied between 35% and 100%. Subjects reported whether their perceived heading was left or right of the midline in a forced-choice task. With the inertial stimulus the eye position had an effect such that the point of subjective equality (PSE) shifted 4.6 ± 2.4° in the gaze direction. With the visual stimulus the PSE shift was 10.2 ± 2.2° opposite the gaze direction, consistent with retinotopic coordinates. Thus with eccentric eye positions the perceived inertial and visual headings were offset ~15°. During the visual-inertial conditions the PSE varied consistently with the relative reliability of these stimuli such that at low visual coherence the PSE was similar to that of the inertial stimulus and at high coherence it was closer to the visual stimulus. On average, the inertial stimulus was weighted near Bayesian ideal predictions, but there was significant deviation from ideal in individual subjects. These findings support visual and inertial cue integration occurring in independent coordinate systems. NEW & NOTEWORTHY In multiple cortical areas visual heading is represented in retinotopic coordinates while inertial heading is in body coordinates. It remains unclear whether multisensory integration occurs in a common coordinate system. The experiments address this using a multisensory integration task with eccentric gaze positions making the effect of coordinate systems clear. The results indicate that the coordinate systems remain separate to the perceptual level and that during the multisensory task the perception depends on relative stimulus reliability. Copyright © 2017 the American Physiological Society.
Ulnar Rotation Osteotomy for Congenital Radial Head Dislocation.
Liu, Ruiyu; Miao, Wusheng; Mu, Mingchao; Wu, Ge; Qu, Jining; Wu, Yongtao
2015-09-01
To evaluate an ulnar rotation osteotomy for congenital anterior dislocation of the radial head. Nine patients (5 boys and 4 girls aged 6 to 13 years) with congenital anterior dislocation of the radial head were treated with ulnar rotation osteotomy. Magnetic resonance imaging of the elbow showed the proximal radioulnar joint on the anterior-lateral side of the ulna rather than on the lateral side in patients with congenital anterior dislocation of the radial head. On the basis of this finding, we performed an osteotomy on the ulna and laterally rotated the proximal radioulnar joint achieving radial head reduction and restoring the anatomical relationship between the radial head and the capitellum. Clinical and radiographical evaluation of the elbow was performed before surgery and at postoperative follow-up. All patients were followed for 13 to 45 months after surgery. Elbow radiography showed that the radiocapitellar joint was reduced in all patients at the last follow-up visit and that the carrying angle was decreased relative to that in the preoperative condition. Elbow stability and the range of elbow flexion motion were improved at the last follow-up. We did not observe ulnar osteotomy site nonunion or elbow osteoarthritis in these patients. Furthermore, radial head dislocation did not recur. At early follow-up, ulnar rotation osteotomy was a safe and effective method for the treatment of congenital anterior dislocation of the radial head. Therapeutic IV. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Validity and reliability of head posture measurement using Microsoft Kinect.
Oh, Baek-Lok; Kim, Jongmin; Kim, Jongshin; Hwang, Jeong-Min; Lee, Jehee
2014-11-01
To investigate the validity and reliability of Microsoft Kinect-based head tracker (KHT) for measuring head posture. Considering the cervical range of motion (CROM) as a reference, one-dimensional and three-dimensional (1D and 3D) head postures of 12 normal subjects (28-58 years of age; 6 women and 6 men) were obtained using the KHT. The KHT was validated by Pearson's correlation coefficient and intraclass correlation (ICC) coefficient. Test-retest reliability of the KHT was determined by its 95% limit of agreement (LoA) with the Bland-Altman plot. Face recognition success rate was evaluated for each head posture. Measurements of 1D and 3D head posture performed using the KHT were very close to those of the CROM with correlation coefficients of 0.99 and 0.97 (p<0.05), respectively, as well as with an ICC of >0.99 and 0.98, respectively. The reliability tests of the KHT in terms of 1D and 3D head postures had 95% LoA angles of approximately ±2.5° and ±6.5°, respectively. The KHT showed good agreement with the CROM and relatively favourable test-retest reliability. Considering its high performance, convenience and low cost, KHT could be clinically used as a head posture-measuring system. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Postural Instability Induced by Visual Motion Stimuli in Patients With Vestibular Migraine
Lim, Yong-Hyun; Kim, Ji-Soo; Lee, Ho-Won; Kim, Sung-Hee
2018-01-01
Patients with vestibular migraine are susceptible to motion sickness. This study aimed to determine whether the severity of posture instability is related to the susceptibility to motion sickness. We used a visual motion paradigm with two conditions of the stimulated retinal field and the head posture to quantify postural stability while maintaining a static stance in 18 patients with vestibular migraine and in 13 age-matched healthy subjects. Three parameters of postural stability showed differences between VM patients and controls: RMS velocity (0.34 ± 0.02 cm/s vs. 0.28 ± 0.02 cm/s), RMS acceleration (8.94 ± 0.74 cm/s2 vs. 6.69 ± 0.87 cm/s2), and sway area (1.77 ± 0.22 cm2 vs. 1.04 ± 0.25 cm2). Patients with vestibular migraine showed marked postural instability of the head and neck when visual stimuli were presented in the retinal periphery. The pseudo-Coriolis effect induced by head roll tilt was not responsible for the main differences in postural instability between patients and controls. Patients with vestibular migraine showed a higher visual dependency and low stability of the postural control system when maintaining quiet standing, which may be related to susceptibility to motion sickness. PMID:29930534
Postural Instability Induced by Visual Motion Stimuli in Patients With Vestibular Migraine.
Lim, Yong-Hyun; Kim, Ji-Soo; Lee, Ho-Won; Kim, Sung-Hee
2018-01-01
Patients with vestibular migraine are susceptible to motion sickness. This study aimed to determine whether the severity of posture instability is related to the susceptibility to motion sickness. We used a visual motion paradigm with two conditions of the stimulated retinal field and the head posture to quantify postural stability while maintaining a static stance in 18 patients with vestibular migraine and in 13 age-matched healthy subjects. Three parameters of postural stability showed differences between VM patients and controls: RMS velocity (0.34 ± 0.02 cm/s vs. 0.28 ± 0.02 cm/s), RMS acceleration (8.94 ± 0.74 cm/s 2 vs. 6.69 ± 0.87 cm/s 2 ), and sway area (1.77 ± 0.22 cm 2 vs. 1.04 ± 0.25 cm 2 ). Patients with vestibular migraine showed marked postural instability of the head and neck when visual stimuli were presented in the retinal periphery. The pseudo-Coriolis effect induced by head roll tilt was not responsible for the main differences in postural instability between patients and controls. Patients with vestibular migraine showed a higher visual dependency and low stability of the postural control system when maintaining quiet standing, which may be related to susceptibility to motion sickness.
NASA Technical Reports Server (NTRS)
Lin, Ray-Quing; Kuang, Weijia
2011-01-01
In this paper, we describe the details of our numerical model for simulating ship solidbody motion in a given environment. In this model, the fully nonlinear dynamical equations governing the time-varying solid-body ship motion under the forces arising from ship wave interactions are solved with given initial conditions. The net force and moment (torque) on the ship body are directly calculated via integration of the hydrodynamic pressure over the wetted surface and the buoyancy effect from the underwater volume of the actual ship hull with a hybrid finite-difference/finite-element method. Neither empirical nor free parametrization is introduced in this model, i.e. no a priori experimental data are needed for modelling. This model is benchmarked with many experiments of various ship hulls for heave, roll and pitch motion. In addition to the benchmark cases, numerical experiments are also carried out for strongly nonlinear ship motion with a fixed heading. These new cases demonstrate clearly the importance of nonlinearities in ship motion modelling.
Al-Qattan, Mohammad M
2012-03-01
Over a 12-year period, the author treated a total of 5 adults (mean age, 23 years) with neglected nonunion of phalangeal neck fractures of the thumb that were sustained in early childhood. Cosmetically, the affected thumb was shorter and smaller than the contralateral thumb. The thumb tip was flail and thumb pinch was weak. X-rays showed a nonunited phalangeal neck fracture with no radiologic evidence of avascular necrosis of the phalangeal head. All patients underwent iliac crest bone grafting. Bone union was obtained in all patients. At final follow-up (mean, 9 months), all patients were satisfied with the cosmetic appearance of the thumb. The thumb length increased by an average of 6 mm (range, 5-8 mm). Pinch improved in the range of 69% to 87% of the power of the contralateral thumb. However, there was restricted range of motion of the interphalangeal joint (mean range of motion of 10 degree only). It was concluded that delayed bone grafting of neglected nonunions of pediatric phalangeal neck fractures of the thumb is a worthwhile procedure and has a high satisfaction rate.
CUSUM analysis of learning curves for the head-mounted microscope in phonomicrosurgery.
Chen, Ting; Vamos, Andrew C; Dailey, Seth H; Jiang, Jack J
2016-10-01
To observe the learning curve of the head-mounted microscope in a phonomicrosurgery simulator using cumulative summation (CUSUM) analysis, which incorporates a magnetic phonomicrosurgery instrument tracking system (MPTS). Retrospective case series. Eight subjects (6 medical students and 2 surgeons inexperienced in phonomicrosurgery) operated on phonomicrosurgical simulation cutting tasks while using the head-mounted microscope for 400 minutes total. Two 20-minute sessions occurred each day for 10 total days, with operation quality (Qs ) and completion time (T) being recorded after each session. Cumulative summation analysis of Qs and T was performed by using subjects' performance data from trials completed using a traditional standing microscope as success criteria. The motion parameters from the head-mounted microscope were significantly better than the standing microscope (P < 0.01), but T was longer than that from the standing microscope (P < 0.01). No subject successfully adapted to the head-mounted microscope, as assessed by CUSUM analysis. Cumulative summation analysis can objectively monitor the learning process associated with a phonomicrosurgical simulator system, ultimately providing a tool to assess learning status. Also, motion parameters determined by our MPTS showed that, although the head-mounted microscope provides better motion control, worse Qs and longer T resulted. This decrease in Qs is likely a result of the relatively unstable visual environment that it provides. Overall, the inexperienced surgeons participating in this study failed to adapt to the head-mounted microscope in our simulated phonomicrosurgery environment. 4 Laryngoscope, 126:2295-2300, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Frosch, K-H; Krause, M; Frings, J; Drenck, T; Akoto, R; Müller, G; Madert, J
2016-10-01
Malreduction of tibial head fractures often leads to malalignment of the lower extremity, pain, limited range of motion and instability. The extent of the complaints and the degree of deformity requires an exact analysis and a standardized approach. True ligamentous instability should be distinguished from pseudoinstability of the joint. Also extra- and intra-articular deformities have to be differentiated. In intra-articular deformities the extent of articular surface displacement, defects and clefts must be accurately evaluated. A specific surgical approach is necessary, which allows adequate visualization, correct osteotomy and refixation of the fractured area of the tibial head. In the long-term course good clinical results are described for intra-articular osteotomies. If the joint is damaged to such an extent that it cannot be reconstructed or in cases of advanced posttraumatic osteoarthritis, total knee arthroplasty may be necessary; however, whenever possible and reasonable, anatomical reconstruction and preservation of the joint should be attempted.
Gait-related strategies for the prevention of plantar ulcer development in the high risk foot.
Bowling, Frank L; Reeves, Neil D; Boulton, Andrew J
2011-05-01
High plantar pressures lead to ulceration in the diabetic foot, particularly in the forefoot region around the metatarsal heads. High plantar pressures persist during gait due to factors such as peripheral neuropathy, foot deformities, limited ankle dorsi flexion range of motion and reduced plantar tissue thickness. Strategies impinging upon gait such as the use of appropriate therapeutic footwear, custom-moulded insoles and injectable silicone can help to reduce plantar pressures and attenuate the risk for ulceration. Shoes adapted with external rocker profiles facilitate plantar flexion and restrict sagittal plane motion of the metatarsophalangeal joint, reducing pressures in the region of the metatarsal heads. Insoles custom-moulded to patient's feet help to reduce plantar pressures and minimise the risk of ulceration in the forefoot region. The loss of subcutaneous fat tissue in the diabetic foot enhances bony prominences and predisposes the foot to high-pressure areas. Silicone is a biocompatible material that can be safely injected into plantar soft tissue to augment tissue thickness and prevent the development of ulceration. This enhancement to the subcutaneous layer is remarkably well retained and is a generally well-adopted procedure in the clinical setting.
SENS-5D trajectory and wind-sensitivity calculations for unguided rockets
NASA Technical Reports Server (NTRS)
Singh, R. P.; Huang, L. C. P.; Cook, R. A.
1975-01-01
A computational procedure is described which numerically integrates the equations of motion of an unguided rocket. Three translational and two angular (roll discarded) degrees of freedom are integrated through the final burnout; and then, through impact, only three translational motions are considered. Input to the routine is: initial time, altitude and velocity, vehicle characteristics, and other defined options. Input format has a wide range of flexibility for special calculations. Output is geared mainly to the wind-weighting procedure, and includes summary of trajectory at burnout, apogee and impact, summary of spent-stage trajectories, detailed position and vehicle data, unit-wind effects for head, tail and cross winds, coriolis deflections, range derivative, and the sensitivity curves (the so called F(Z) and DF(Z) curves). The numerical integration procedure is a fourth-order, modified Adams-Bashforth Predictor-Corrector method. This method is supplemented by a fourth-order Runge-Kutta method to start the integration at t=0 and whenever error criteria demand a change in step size.
Ju, Harang; Kim, Siyong; Read, Paul; Trifiletti, Daniel; Harrell, Andrew; Libby, Bruce
2015-01-01
In radiotherapy, only a few immobilization systems, such as open‐face mask and head mold with a bite plate, are available for claustrophobic patients with a certain degree of discomfort. The purpose of this study was to develop a remote‐controlled and self‐contained audiovisual (AV)‐aided interactive system with the iPad mini with Retina display for intrafractional motion management in brain/H&N (head and neck) radiotherapy for claustrophobic patients. The self‐contained, AV‐aided interactive system utilized two tablet computers: one for AV‐aided interactive guidance for the subject and the other for remote control by an operator. The tablet for audiovisual guidance traced the motion of a colored marker using the built‐in front‐facing camera, and the remote control tablet at the control room used infrastructure Wi‐Fi networks for real‐time communication with the other tablet. In the evaluation, a programmed QUASAR motion phantom was used to test the temporal and positional accuracy and resolution. Position data were also obtained from ten healthy volunteers with and without guidance to evaluate the reduction of intrafractional head motion in simulations of a claustrophobic brain or H&N case. In the phantom study, the temporal and positional resolution was 24 Hz and 0.2 mm. In the volunteer study, the average superior–inferior and right–left displacement was reduced from 1.9 mm to 0.3 mm and from 2.2 mm to 0.2 mm with AV‐aided interactive guidance, respectively. The superior–inferior and right–left positional drift was reduced from 0.5 mm/min to 0.1 mm/min and from 0.4 mm/min to 0.04 mm/min with audiovisual‐aided interactive guidance. This study demonstrated a reduction in intrafractional head motion using a remote‐controlled and self‐contained AV‐aided interactive system of iPad minis with Retina display, easily obtainable and cost‐effective tablet computers. This approach can potentially streamline clinical flow for claustrophobic patients without a head mask and also allows patients to practice self‐motion management before radiation treatment delivery. PACS number: 87.55.Gh
Badachhape, Andrew A; Okamoto, Ruth J; Johnson, Curtis L; Bayly, Philip V
2018-05-17
The objective of this study was to characterize the relationships between motion in the scalp, skull, and brain. In vivo estimates of motion transmission from the skull to the brain may illuminate the mechanics of traumatic brain injury. Because of challenges in directly sensing skull motion, it is useful to know how well motion of soft tissue of the head, i.e., the scalp, can approximate skull motion or predict brain tissue deformation. In this study, motion of the scalp and brain were measured using magnetic resonance elastography (MRE) and separated into components due to rigid-body displacement and dynamic deformation. Displacement estimates in the scalp were calculated using low motion-encoding gradient strength in order to reduce "phase wrapping" (an ambiguity in displacement estimates caused by the 2 π-periodicity of MRE phase contrast). MRE estimates of scalp and brain motion were compared to skull motion estimated from three tri-axial accelerometers. Comparison of the relative amplitudes and phases of harmonic motion in the scalp, skull, and brain of six human subjects indicate that data from scalp-based sensors should be used with caution to estimate skull kinematics, but that fairly consistent relationships exist between scalp, skull, and brain motion. In addition, the measured amplitude and phase relationships of scalp, skull, and brain can be used to evaluate and improve mathematical models of head biomechanics. Copyright © 2018 Elsevier Ltd. All rights reserved.
Virtual Reality: You Are There
NASA Technical Reports Server (NTRS)
1993-01-01
Telepresence or "virtual reality," allows a person, with assistance from advanced technology devices, to figuratively project himself into another environment. This technology is marketed by several companies, among them Fakespace, Inc., a former Ames Research Center contractor. Fakespace developed a teleoperational motion platform for transmitting sounds and images from remote locations. The "Molly" matches the user's head motion and, when coupled with a stereo viewing device and appropriate software, creates the telepresence experience. Its companion piece is the BOOM-the user's viewing device that provides the sense of involvement in the virtual environment. Either system may be used alone. Because suits, gloves, headphones, etc. are not needed, a whole range of commercial applications is possible, including computer-aided design techniques and virtual reality visualizations. Customers include Sandia National Laboratories, Stanford Research Institute and Mattel Toys.
The Relative Contribution of Interaural Time and Magnitude Cues to Dynamic Sound Localization
NASA Technical Reports Server (NTRS)
Wenzel, Elizabeth M.; Null, Cynthia H. (Technical Monitor)
1995-01-01
This paper presents preliminary data from a study examining the relative contribution of interaural time differences (ITDs) and interaural level differences (ILDs) to the localization of virtual sound sources both with and without head motion. The listeners' task was to estimate the apparent direction and distance of virtual sources (broadband noise) presented over headphones. Stimuli were synthesized from minimum phase representations of nonindividualized directional transfer functions; binaural magnitude spectra were derived from the minimum phase estimates and ITDs were represented as a pure delay. During dynamic conditions, listeners were encouraged to move their heads; the position of the listener's head was tracked and the stimuli were synthesized in real time using a Convolvotron to simulate a stationary external sound source. ILDs and ITDs were either correctly or incorrectly correlated with head motion: (1) both ILDs and ITDs correctly correlated, (2) ILDs correct, ITD fixed at 0 deg azimuth and 0 deg elevation, (3) ITDs correct, ILDs fixed at 0 deg, 0 deg. Similar conditions were run for static conditions except that none of the cues changed with head motion. The data indicated that, compared to static conditions, head movements helped listeners to resolve confusions primarily when ILDs were correctly correlated, although a smaller effect was also seen for correct ITDs. Together with the results for static conditions, the data suggest that localization tends to be dominated by the cue that is most reliable or consistent, when reliability is defined by consistency over time as well as across frequency bands.
Dynamic in vivo 3D atlantoaxial spine kinematics during upright rotation.
Anderst, William; Rynearson, Bryan; West, Tyler; Donaldson, William; Lee, Joon
2017-07-26
Diagnosing dysfunctional atlantoaxial motion is challenging given limitations of current diagnostic imaging techniques. Three-dimensional imaging during upright functional motion may be useful in identifying dynamic instability not apparent on static imaging. Abnormal atlantoaxial motion has been linked to numerous pathologies including whiplash, cervicogenic headaches, C2 fractures, and rheumatoid arthritis. However, normal C1/C2 rotational kinematics under dynamic physiologic loading have not been previously reported owing to imaging difficulties. The objective of this study was to determine dynamic three-dimensional in vivo C1/C2 kinematics during upright axial rotation. Twenty young healthy adults performed full head rotation while seated within a biplane X-ray system while radiographs were collected at 30 images per second. Six degree-of-freedom kinematics were determined for C1 and C2 via a validated volumetric model-based tracking process. The maximum global head rotation (to one side) was 73.6±8.3°, whereas maximum C1 rotation relative to C2 was 36.8±6.7°. The relationship between C1/C2 rotation and head rotation was linear through midrange motion (±20° head rotation from neutral) in a nearly 1:1 ratio. Coupled rotation between C1 and C2 included 4.5±3.1° of flexion and 6.4±8.2° of extension, and 9.8±3.8° of contralateral bending. Translational motion of C1 relative to C2 was 7.8±1.5mm ipsilaterally, 2.2±1.2mm inferiorly, and 3.3±1.0mm posteriorly. We believe this is the first study describing 3D dynamic atlantoaxial kinematics under true physiologic conditions in healthy subjects. C1/C2 rotation accounts for approximately half of total head axial rotation. Additionally, C1 undergoes coupled flexion/extension and contralateral bending, in addition to inferior, lateral and posterior translation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rotational dynamics of spin-labeled F-actin during activation of myosin S1 ATPase using caged ATP.
Ostap, E. M.; Thomas, D. D.
1991-01-01
The most probable source of force generation in muscle fibers in the rotation of the myosin head when bound to actin. This laboratory has demonstrated that ATP induces microsecond rotational motions of spin-labeled myosin heads bound to actin (Berger, C. L. E. C. Svensson, and D. D. Thomas. 1989. Proc. Natl. Acad. Sci. USA. 86:8753-8757). Our goal is to determine whether the observed ATP-induced rotational motions of actin-bound heads are accompanied by changes in actin rotational motions. We have used saturation transfer electron paramagnetic resonance (ST-EPR) and laser-induced photolysis of caged ATP to monitor changes in the microsecond rotational dynamics of spin-labeled F-actin in the presence of myosin subfragment-1 (S1). A maleimide spin label was attached selectively to cys-374 on actin. In the absence of ATP (with or without caged ATP), the ST-EPR spectrum (corresponding to an effective rotational time of approximately 150 microseconds) was essentially the same as observed for the same spin label bound to cys-707 (SH1) on S1, indicating that S1 is rigidly bound to actin in rigor. At normal ionic strength (micro = 186 mM), a decrease in ST-EPR intensity (increase in microsecond F-actin mobility) was clearly indicated upon photolysis of 1 mM caged ATP with a 50-ms, 351-nm laser pulse. This increase in mobility is due to the complete dissociation of Si from the actin filament. At low ionic strength (micro, = 36 mM), when about half the Si heads remain bound during ATP hydrolysis, no change in the actin mobility was detected, despite much faster motions of labeled S1 bound to actin. Therefore, we conclude that the active interaction of Si, actin,and ATP induces rotation of myosin heads relative to actin, but does not affect the microsecond rotational motion of actin itself, as detected at cys-374 of actin. PMID:1651780
Walking Ahead: The Headed Social Force Model.
Farina, Francesco; Fontanelli, Daniele; Garulli, Andrea; Giannitrapani, Antonio; Prattichizzo, Domenico
2017-01-01
Human motion models are finding an increasing number of novel applications in many different fields, such as building design, computer graphics and robot motion planning. The Social Force Model is one of the most popular alternatives to describe the motion of pedestrians. By resorting to a physical analogy, individuals are assimilated to point-wise particles subject to social forces which drive their dynamics. Such a model implicitly assumes that humans move isotropically. On the contrary, empirical evidence shows that people do have a preferred direction of motion, walking forward most of the time. Lateral motions are observed only in specific circumstances, such as when navigating in overcrowded environments or avoiding unexpected obstacles. In this paper, the Headed Social Force Model is introduced in order to improve the realism of the trajectories generated by the classical Social Force Model. The key feature of the proposed approach is the inclusion of the pedestrians' heading into the dynamic model used to describe the motion of each individual. The force and torque representing the model inputs are computed as suitable functions of the force terms resulting from the traditional Social Force Model. Moreover, a new force contribution is introduced in order to model the behavior of people walking together as a single group. The proposed model features high versatility, being able to reproduce both the unicycle-like trajectories typical of people moving in open spaces and the point-wise motion patterns occurring in high density scenarios. Extensive numerical simulations show an increased regularity of the resulting trajectories and confirm a general improvement of the model realism.
Knox, Joanna Joy; Beilstein, Darren Jay; Charles, Scott Darren; Aarseth, Geir Arne; Rayar, Shivanthi; Treleaven, Julia; Hodges, Paul William
2006-01-01
It has been shown that perception of elbow joint position is affected by changes in head and neck position. Further, people with whiplash-associated disorders (WAD) present with deficits in upper limb coordination and movement. This study is aimed to determine whether the effect of changes in head position on elbow joint position error (JPE) is more pronounced in people with WAD, and to determine whether this is related to the participant's pain and anxiety levels. Nine people with chronic and disabling WAD and 11 healthy people participated in this experiment. The ability to reproduce a position at the elbow joint was assessed after changes in the position of the head and neck to 30 degrees , and with the head in the midline. Pain was monitored in WAD participants. Absolute elbow JPE with the head in neutral was not different between WAD and control participants (P=0.5). Changes in the head and neck position increased absolute elbow JPE in the WAD group (P<0.05), but did not affect elbow JPE in the control group (P=0.4). There was a connection between pain during testing and the effect of changes in head position on elbow JPE (P<0.05). Elbow JPE is affected by movement of the head and neck, with smaller angles of neck rotation in people with WAD than in healthy individuals. This observation may explain deficits in upper limb coordination in people with WAD, which may be due to the presence of pain or reduced range of motion in this population.
NASA Technical Reports Server (NTRS)
Wall, Conrad., III
1999-01-01
In addition to adapting to microgravity, major neurovestibular problems of space flight include postflight difficulties with standing, walking, turning corners, and other activities that require stable upright posture and gaze stability. These difficulties inhibit astronauts' ability to stand or escape from their vehicle during emergencies. The long-ter7n goal of the NSBRI is the development of countermeasures to ameliorate the effects of long duration space flight. These countermeasures must be tested with valid and reliable tools. This project aims to develop quantitative, parametric approaches for assessing gaze stability and spatial orientation during normal gait and when gait is perturbed. Two of this year's most important findings concern head fixation distance and ideal trajectory analysis. During a normal cycle of walking the head moves up and down linearly. A simultaneous angular pitching motion of the head keeps it aligned toward an imaginary point in space at a distance of about one meter in front of a subject and along the line of march. This distance is called the head fixation distance. Head fixation distance provides the fundamental framework necessary for understanding the functional significance of the vestibular reflexes that couple head motion to eye motion. This framework facilitates the intelligent design of counter-measures for the effects of exposure to microgravity upon the vestibular ocular reflexes. Ideal trajectory analysis is a simple candidate countermeasure based upon quantifying body sway during repeated up and down stair stepping. It provides one number that estimates the body sway deviation from an ideal sinusoidal body sway trajectory normalized on the subject's height. This concept has been developed with NSBRI funding in less than one year. These findings are explained in more detail below. Compared to assessments of the vestibuo-ocular reflex, analysis of vestibular effects on locomotor function is relatively less well developed and quantified. We are improving this situation by applying methodologies such as nonlinear orbital stability to quantify responses and by using multivariate statistical approaches to link together the responses across separate tests. In this way we can exploit the information available and increase the ability to discriminate between normal and pathological responses. Measures of stability and orientation are compared to measures such as dynamic visual acuity and with balance function tests. The responses of normal human subjects and of patients having well documented pathophysiologies are being characterized. When these studies are completed, we should have a clearer idea about normal and abnormal patterns of eye, head, and body movements during locomotion and their stability in a wide range of environments. We plan eventually to use this information to validate the efficacy of candidate neurovestibular and neuromuscular rehabilitative techniques. Some representative studies made during this year are summarized.
Picelli, Alessandro; Tamburin, Stefano; Bonetti, Paola; Fontana, Carla; Barausse, Martina; Dambruoso, Francesca; Gajofatto, Francesca; Santilli, Valter; Smania, Nicola
2012-11-01
The aim of this study was to compare the clinical outcomes of manual needle placement, electrical stimulation, and ultrasonography-guided techniques for botulinum toxin injection into the gastrocnemius of adults with spastic equinus after stroke. After randomization into three groups, each patient received the same dose of botulinum toxin type A into the lateral and medial head of the gastrocnemius muscle (OnabotulinumtoxinA, 100U per head) of the affected leg. The manual needle placement group (n = 15) underwent injections using anatomic landmarks and palpation; the electrical stimulation group (n = 15) received injections with electrical stimulation guidance; and the ultrasonography group (n = 17) was injected under sonographic guidance. The modified Ashworth scale, the Tardieu scale, and the ankle passive range of motion were measured at baseline and 1 mo after injection. Nonparametric statistical analysis was used. One month after injection, the modified Ashworth scale improved better in the ultrasonography group than in the manual needle placement group (P = 0.008). The ankle passive range of motion improved better in the ultrasonography group than in the electrical stimulation (P = 0.004) and manual needle placement (P < 0.001) groups. No difference was found between groups for the Tardieu scale. Ultrasonography-guided injection technique could improve the clinical outcome of botulinum toxin injections into the gastrocnemius of adults with spastic equinus.
TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belcher, AH; Liu, X; Wiersma, R
Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics roboticsmore » stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning patients to isocenter with high 6DOF accuracy.« less
Kinematics of a Head-Neck Model Simulating Whiplash
NASA Astrophysics Data System (ADS)
Colicchia, Giuseppe; Zollman, Dean; Wiesner, Hartmut; Sen, Ahmet Ilhan
2008-02-01
A whiplash event is a relative motion between the head and torso that occurs in rear-end automobile collisions. In particular, the large inertia of the head results in a horizontal translation relative to the thorax. This paper describes a simulation of the motion of the head and neck during a rear-end (whiplash) collision. A head-neck model that qualitatively undergoes the same forces acting in whiplash and shows the same behavior is used to analyze the kinematics of both the head and the cervical spine and the resulting neck loads. The rapid acceleration during a whiplash event causes the extension and flexion of the cervical spine, which in turn can cause dislocated vertebrae, torn ligaments, intervertebral disc herniation, and other trauma that appear to be the likely causes of subsequent painful headache or neck pain symptoms. Thus, whiplash provides a connection between the dynamics of the human body and physics. Its treatment can enliven the usual teaching in kinematics, and both theoretical and experimental approaches provide an interesting biological context to teach introductory principles of mechanics.
Liu, Sheng; Angelaki, Dora E.
2009-01-01
Visual and vestibular signals converge onto the dorsal medial superior temporal area (MSTd) of the macaque extrastriate visual cortex, which is thought to be involved in multisensory heading perception for spatial navigation. Peripheral otolith information, however, is ambiguous and cannot distinguish linear accelerations experienced during self-motion from those due to changes in spatial orientation relative to gravity. Here we show that, unlike peripheral vestibular sensors but similar to lobules 9 and 10 of the cerebellar vermis (nodulus and uvula), MSTd neurons respond selectively to heading and not to changes in orientation relative to gravity. In support of a role in heading perception, MSTd vestibular responses are also dominated by velocity-like temporal dynamics, which might optimize sensory integration with visual motion information. Unlike the cerebellar vermis, however, MSTd neurons also carry a spatial orientation-independent rotation signal from the semicircular canals, which could be useful in compensating for the effects of head rotation on the processing of optic flow. These findings show that vestibular signals in MSTd are appropriately processed to support a functional role in multisensory heading perception. PMID:19605631
Accident investigation: Analysis of aircraft motions from ATC radar recordings
NASA Technical Reports Server (NTRS)
Wingrove, R. C.
1976-01-01
A technique was developed for deriving time histories of an aircraft's motion from air traffic control (ATC) radar records. This technique uses the radar range and azimuth data, along with the downlinked altitude data (from an onboard Mode-C transponder), to derive an expanded set of data which includes airspeed, lift, thrust-drag, attitude angles (pitch, roll, and heading), etc. This method of analyzing aircraft motions was evaluated through flight experiments which used the CV-990 research aircraft and recordings from both the enroute and terminal ATC radar systems. The results indicate that the values derived from the ATC radar records are for the most part in good agreement with the corresponding values obtained from airborne measurements. In an actual accident, this analysis of ATC radar records can complement the flight-data recorders, now onboard airliners, and provide a source of recorded information for other types of aircraft that are equipped with Mode-C transponders but not with onboard recorders.
A comparison of four office chairs using biomechanical measures.
Bush, Tamara Reid; Hubbard, Robert P
2008-08-01
The authors sought to use biomechanical measures, including motion and pressure, to compare four office chairs. The fit of a person to a chair is related to the geometric and kinematic compatibility between the two. This geometric compatibility influences the motions that are allowed or prohibited and the support pressures at the body-chair interface. Thus, during evaluation, it is necessary to treat the chair and user as a system. Four dynamic test conditions were evaluated with 14 participants of varying anthropometries. Test conditions were selected to compare the ability to accommodate primary and secondary motions (recline and spinal articulation) of seated occupants. The ability of a chair to allow recline, yet maintain head and hand positions, was compared across chairs. Also, the ability of each chair to allow and support spinal articulation was evaluated. Motion data for the chair, head, thorax, pelvis, and extremities were collected along with chair back pressures. Upon completion of testing, subjective assessments were also conducted. Statistically significant differences were found between chairs relative to head and hand motions. Also, significant differences were noted for the chairs' ability to move with the body during spinal articulation and the ability to provide support. Subjective assessments also yielded differences. Biomechanical analyses using motions and pressures can be conducted on office chairs with significant differences detected in their performance. Biomechanical assessments can be used to compare and contrast office chairs in terms that are relatable to fatigue reduction as well as operator performance.
Vector Graph Assisted Pedestrian Dead Reckoning Using an Unconstrained Smartphone
Qian, Jiuchao; Pei, Ling; Ma, Jiabin; Ying, Rendong; Liu, Peilin
2015-01-01
The paper presents a hybrid indoor positioning solution based on a pedestrian dead reckoning (PDR) approach using built-in sensors on a smartphone. To address the challenges of flexible and complex contexts of carrying a phone while walking, a robust step detection algorithm based on motion-awareness has been proposed. Given the fact that step length is influenced by different motion states, an adaptive step length estimation algorithm based on motion recognition is developed. Heading estimation is carried out by an attitude acquisition algorithm, which contains a two-phase filter to mitigate the distortion of magnetic anomalies. In order to estimate the heading for an unconstrained smartphone, principal component analysis (PCA) of acceleration is applied to determine the offset between the orientation of smartphone and the actual heading of a pedestrian. Moreover, a particle filter with vector graph assisted particle weighting is introduced to correct the deviation in step length and heading estimation. Extensive field tests, including four contexts of carrying a phone, have been conducted in an office building to verify the performance of the proposed algorithm. Test results show that the proposed algorithm can achieve sub-meter mean error in all contexts. PMID:25738763
An autonomous sperm-like propulsor in a quiescent flow
NASA Astrophysics Data System (ADS)
Kim, Boyoung; Park, Sung Goon; Sung, Hyung Jin
2016-11-01
Flapping motions of flexible fins are widespread in nature. Birds, fish, and insects use their wings, fins, or bodies to stay afloat and to advance forward in the surrounding fluids. It is important to understand the physics of the flapping motions to utilize them for the biomimetic machines. In the present study, we introduce a sperm-like propulsor that consists of a rigid head containing genetic information and a flapping flexible tail for propulsion. The head gives a sinusoidal torque to the leading edge of the tail, and the flexible tail flaps along the leading edge. In other words, the sperm-like propulsor is moved by an oscillating relative angle between the head and the leading edge of the tail. Unlike self-propelled heaving and pitching fins, the 'autonomous' sperm-like propulsor has no prescribed motion or constraint referenced from outside coordinates. The penalty method and the immersed boundary method are used to solve the autonomous sperm-like propulsor in a quiescent flow. The cruising speed and the propulsive efficiency of the propulsor are explored as a function of the head size (D/ L) , the pitching angle (θ0) , the pitching frequency (f) , and the distance from the wall (G/ L) .
Automatic facial animation parameters extraction in MPEG-4 visual communication
NASA Astrophysics Data System (ADS)
Yang, Chenggen; Gong, Wanwei; Yu, Lu
2002-01-01
Facial Animation Parameters (FAPs) are defined in MPEG-4 to animate a facial object. The algorithm proposed in this paper to extract these FAPs is applied to very low bit-rate video communication, in which the scene is composed of a head-and-shoulder object with complex background. This paper addresses the algorithm to automatically extract all FAPs needed to animate a generic facial model, estimate the 3D motion of head by points. The proposed algorithm extracts human facial region by color segmentation and intra-frame and inter-frame edge detection. Facial structure and edge distribution of facial feature such as vertical and horizontal gradient histograms are used to locate the facial feature region. Parabola and circle deformable templates are employed to fit facial feature and extract a part of FAPs. A special data structure is proposed to describe deformable templates to reduce time consumption for computing energy functions. Another part of FAPs, 3D rigid head motion vectors, are estimated by corresponding-points method. A 3D head wire-frame model provides facial semantic information for selection of proper corresponding points, which helps to increase accuracy of 3D rigid object motion estimation.
Marker-less multi-frame motion tracking and compensation in PET-brain imaging
NASA Astrophysics Data System (ADS)
Lindsay, C.; Mukherjee, J. M.; Johnson, K.; Olivier, P.; Song, X.; Shao, L.; King, M. A.
2015-03-01
In PET brain imaging, patient motion can contribute significantly to the degradation of image quality potentially leading to diagnostic and therapeutic problems. To mitigate the image artifacts resulting from patient motion, motion must be detected and tracked then provided to a motion correction algorithm. Existing techniques to track patient motion fall into one of two categories: 1) image-derived approaches and 2) external motion tracking (EMT). Typical EMT requires patients to have markers in a known pattern on a rigid too attached to their head, which are then tracked by expensive and bulky motion tracking camera systems or stereo cameras. This has made marker-based EMT unattractive for routine clinical application. Our main contributions are the development of a marker-less motion tracking system that uses lowcost, small depth-sensing cameras which can be installed in the bore of the imaging system. Our motion tracking system does not require anything to be attached to the patient and can track the rigid transformation (6-degrees of freedom) of the patient's head at a rate 60 Hz. We show that our method can not only be used in with Multi-frame Acquisition (MAF) PET motion correction, but precise timing can be employed to determine only the necessary frames needed for correction. This can speeds up reconstruction by eliminating the unnecessary subdivision of frames.
Effects of Kinesio taping and exercise on forward head posture.
Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi
2017-01-01
Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.
A Unified Model of Heading and Path Perception in Primate MSTd
Layton, Oliver W.; Browning, N. Andrew
2014-01-01
Self-motion, steering, and obstacle avoidance during navigation in the real world require humans to travel along curved paths. Many perceptual models have been proposed that focus on heading, which specifies the direction of travel along straight paths, but not on path curvature, which humans accurately perceive and is critical to everyday locomotion. In primates, including humans, dorsal medial superior temporal area (MSTd) has been implicated in heading perception. However, the majority of MSTd neurons respond optimally to spiral patterns, rather than to the radial expansion patterns associated with heading. No existing theory of curved path perception explains the neural mechanisms by which humans accurately assess path and no functional role for spiral-tuned cells has yet been proposed. Here we present a computational model that demonstrates how the continuum of observed cells (radial to circular) in MSTd can simultaneously code curvature and heading across the neural population. Curvature is encoded through the spirality of the most active cell, and heading is encoded through the visuotopic location of the center of the most active cell's receptive field. Model curvature and heading errors fit those made by humans. Our model challenges the view that the function of MSTd is heading estimation, based on our analysis we claim that it is primarily concerned with trajectory estimation and the simultaneous representation of both curvature and heading. In our model, temporal dynamics afford time-history in the neural representation of optic flow, which may modulate its structure. This has far-reaching implications for the interpretation of studies that assume that optic flow is, and should be, represented as an instantaneous vector field. Our results suggest that spiral motion patterns that emerge in spatio-temporal optic flow are essential for guiding self-motion along complex trajectories, and that cells in MSTd are specifically tuned to extract complex trajectory estimation from flow. PMID:24586130
Charbonnier, Caecilia; Kolo, Frank C; Duthon, Victoria B; Magnenat-Thalmann, Nadia; Becker, Christoph D; Hoffmeyer, Pierre; Menetrey, Jacques
2011-03-01
Early hip osteoarthritis in dancers could be explained by femoroacetabular impingements. However, there is a lack of validated noninvasive methods and dynamic studies to ascertain impingement during motion. Moreover, it is unknown whether the femoral head and acetabulum are congruent in typical dancing positions. The practice of some dancing movements could cause a loss of hip joint congruence and recurrent impingements, which could lead to early osteoarthritis. Descriptive laboratory study. Eleven pairs of female dancer's hips were motion captured with an optical tracking system while performing 6 different dancing movements. The resulting computed motions were applied to patient-specific hip joint 3-dimensional models based on magnetic resonance images. While visualizing the dancer's hip in motion, the authors detected impingements using computer-assisted techniques. The range of motion and congruence of the hip joint were also quantified in those 6 recorded dancing movements. The frequency of impingement and subluxation varied with the type of movement. Four dancing movements (développé à la seconde, grand écart facial, grand écart latéral, and grand plié) seem to induce significant stress in the hip joint, according to the observed high frequency of impingement and amount of subluxation. The femoroacetabular translations were high (range, 0.93 to 6.35 mm). For almost all movements, the computed zones of impingement were mainly located in the superior or posterosuperior quadrant of the acetabulum, which was relevant with respect to radiologically diagnosed damaged zones in the labrum. All dancers' hips were morphologically normal. Impingements and subluxations are frequently observed in typical ballet movements, causing cartilage hypercompression. These movements should be limited in frequency. The present study indicates that some dancing movements could damage the hip joint, which could lead to early osteoarthritis.
Neck Strength Imbalance Correlates With Increased Head Acceleration in Soccer Heading
Dezman, Zachary D.W.; Ledet, Eric H.; Kerr, Hamish A.
2013-01-01
Background: Soccer heading is using the head to directly contact the ball, often to advance the ball down the field or score. It is a skill fundamental to the game, yet it has come under scrutiny. Repeated subclinical effects of heading may compound over time, resulting in neurologic deficits. Greater head accelerations are linked to brain injury. Developing an understanding of how the neck muscles help stabilize and reduce head acceleration during impact may help prevent brain injury. Hypothesis: Neck strength imbalance correlates to increasing head acceleration during impact while heading a soccer ball. Study Design: Observational laboratory investigation. Methods: Sixteen Division I and II collegiate soccer players headed a ball in a controlled indoor laboratory setting while player motions were recorded by a 14-camera Vicon MX motion capture system. Neck flexor and extensor strength of each player was measured using a spring-type clinical dynamometer. Results: Players were served soccer balls by hand at a mean velocity of 4.29 m/s (±0.74 m/s). Players returned the ball to the server using a heading maneuver at a mean velocity of 5.48 m/s (±1.18 m/s). Mean neck strength difference was positively correlated with angular head acceleration (rho = 0.497; P = 0.05), with a trend toward significance for linear head acceleration (rho = 0.485; P = 0.057). Conclusion: This study suggests that symmetrical strength in neck flexors and extensors reduces head acceleration experienced during low-velocity heading in experienced collegiate players. Clinical Relevance: Balanced neck strength may reduce head acceleration cumulative subclinical injury. Since neck strength is a measureable and amenable strength training intervention, this may represent a modifiable intrinsic risk factor for injury. PMID:24459547
Yuan, Jing; Yeung, David Ka Wai; Mok, Greta S P; Bhatia, Kunwar S; Wang, Yi-Xiang J; Ahuja, Anil T; King, Ann D
2014-01-01
To technically investigate the non-Gaussian diffusion of head and neck diffusion weighted imaging (DWI) at 3 Tesla and compare advanced non-Gaussian diffusion models, including diffusion kurtosis imaging (DKI), stretched-exponential model (SEM), intravoxel incoherent motion (IVIM) and statistical model in the patients with nasopharyngeal carcinoma (NPC). After ethics approval was granted, 16 patients with NPC were examined using DWI performed at 3T employing an extended b-value range from 0 to 1500 s/mm(2). DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models on primary tumor, metastatic node, spinal cord and muscle. Non-Gaussian parameter maps were generated and compared to apparent diffusion coefficient (ADC) maps in NPC. Diffusion in NPC exhibited non-Gaussian behavior at the extended b-value range. Non-Gaussian models achieved significantly better fitting of DWI signal than the mono-exponential model. Non-Gaussian diffusion coefficients were substantially different from mono-exponential ADC both in magnitude and histogram distribution. Non-Gaussian diffusivity in head and neck tissues and NPC lesions could be assessed by using non-Gaussian diffusion models. Non-Gaussian DWI analysis may reveal additional tissue properties beyond ADC and holds potentials to be used as a complementary tool for NPC characterization.
van der Wel, Robrecht P; Welsh, Timothy; Böckler, Anne
2018-01-01
The direction of gaze towards or away from an observer has immediate effects on attentional processing in the observer. Previous research indicates that faces with direct gaze are processed more efficiently than faces with averted gaze. We recently reported additional processing advantages for faces that suddenly adopt direct gaze (abruptly shift from averted to direct gaze) relative to static direct gaze (always in direct gaze), sudden averted gaze (abruptly shift from direct to averted gaze), and static averted gaze (always in averted gaze). Because changes in gaze orientation in previous study co-occurred with changes in head orientation, it was not clear if the effect is contingent on face or eye processing, or whether it requires both the eyes and the face to provide consistent information. The present study delineates the impact of head orientation, sudden onset motion cues, and gaze cues. Participants completed a target-detection task in which head position remained in a static averted or direct orientation while sudden onset motion and eye gaze cues were manipulated within each trial. The results indicate a sudden direct gaze advantage that resulted from the additive role of motion and gaze cues. Interestingly, the orientation of the face towards or away from the observer did not influence the sudden direct gaze effect, suggesting that eye gaze cues, not face orientation cues, are critical for the sudden direct gaze effect.
The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T.; Halliday, Michael J. C.; Ackland, Timothy R.
2014-01-01
Introduction: The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Materials and Methods: Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Results: Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI −1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Discussion: Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Level of Evidence IV: Case series without comparison group. PMID:25258498
The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T; Halliday, Michael J C; Ackland, Timothy R
2014-07-01
The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI -1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Case series without comparison group.
An attempt to detect lameness in galloping horses by use of body-mounted inertial sensors.
Lopes, Marco A F; Dearo, Antonio C O; Lee, Allen; Reed, Shannon K; Kramer, Joanne; Pai, P Frank; Yonezawa, Yoshiharu; Maki, Hiromitchi; Morgan, Terry L; Wilson, David A; Keegan, Kevin G
2016-10-01
OBJECTIVE To evaluate head, pelvic, and limb movement to detect lameness in galloping horses. ANIMALS 12 Thoroughbreds. PROCEDURES Movement data were collected with inertial sensors mounted on the head, pelvis, and limbs of horses trotting and galloping in a straight line before and after induction of forelimb and hind limb lameness by use of sole pressure. Successful induction of lameness was determined by measurement of asymmetric vertical head and pelvic movement during trotting. Differences in gallop strides before and after induction of lameness were evaluated with paired-sample statistical analysis and neural network training and testing. Variables included maximum, minimum, range, and time indices of vertical head and pelvic acceleration, head rotation in the sagittal plane, pelvic rotation in the frontal plane, limb contact intervals, stride durations, and limb lead preference. Difference between median standardized gallop strides for each limb lead before and after induction of lameness was calculated as the sum of squared differences at each time index and assessed with a 2-way ANOVA. RESULTS Head and pelvic acceleration and rotation, limb timing, stride duration measurements, and limb lead preference during galloping were not significantly different before and after induction of lameness in the forelimb or hind limb. Differences between limb leads before induction of lameness were similar to or greater than differences within limb leads before and after lameness induction. CONCLUSIONS AND CLINICAL RELEVANCE Galloping horses maintained asymmetry of head, pelvic, and limb motion between limb leads that was unrelated to lameness.
A kinematic model for 3-D head-free gaze-shifts
Daemi, Mehdi; Crawford, J. Douglas
2015-01-01
Rotations of the line of sight are mainly implemented by coordinated motion of the eyes and head. Here, we propose a model for the kinematics of three-dimensional (3-D) head-unrestrained gaze-shifts. The model was designed to account for major principles in the known behavior, such as gaze accuracy, spatiotemporal coordination of saccades with vestibulo-ocular reflex (VOR), relative eye and head contributions, the non-commutativity of rotations, and Listing's and Fick constraints for the eyes and head, respectively. The internal design of the model was inspired by known and hypothesized elements of gaze control physiology. Inputs included retinocentric location of the visual target and internal representations of initial 3-D eye and head orientation, whereas outputs were 3-D displacements of eye relative to the head and head relative to shoulder. Internal transformations decomposed the 2-D gaze command into 3-D eye and head commands with the use of three coordinated circuits: (1) a saccade generator, (2) a head rotation generator, (3) a VOR predictor. Simulations illustrate that the model can implement: (1) the correct 3-D reference frame transformations to generate accurate gaze shifts (despite variability in other parameters), (2) the experimentally verified constraints on static eye and head orientations during fixation, and (3) the experimentally observed 3-D trajectories of eye and head motion during gaze-shifts. We then use this model to simulate how 2-D eye-head coordination strategies interact with 3-D constraints to influence 3-D orientations of the eye-in-space, and the implications of this for spatial vision. PMID:26113816
Siegmund, Gunter P; Sanderson, David J; Myers, Barry S; Inglis, J Timothy
2003-04-01
To examine whether habituation confounds the study of whiplash injury using human subjects, we quantified changes in the magnitude and temporal development of the neck muscle electromyogram and peak linear and angular head/torso kinematics of subjects exposed to sequential whiplash-like perturbations. Forty-four seated subjects (23F, 21M) underwent 11 consecutive forward horizontal perturbations (peak sled acceleration=1.5 g). Electromyographic (EMG) activity was recorded over the sternocleidomastoid (SCM) and cervical paraspinal (PARA) muscles with surface electrodes, and head and torso kinematics were measured using linear and angular accelerometers and a 3D motion analysis system. EMG onset occurred at reflex latencies (67-75 ms in SCM) and did not vary with repeated perturbations. EMG amplitude was significantly attenuated by the second perturbation in PARA muscles and by the third perturbation in SCM muscles. The mean decrement in EMG amplitude between the first trial and the mean of the last five trials was between 41% and 64%. Related kinematic changes ranged from a 21% increase in head extension angle to a 29% decrease in forward acceleration at the forehead, and were also significantly different by the second exposure in some variables. Although a wider range of perturbation intensities and inter-perturbation intervals need to be studied, the significant changes observed in both muscle and kinematic variables by the second perturbation indicated that habituation was a potential confounder of whiplash injury studies using repeated perturbations of human subjects.
Spin-wave-driven high-speed domain-wall motions in soft magnetic nanotubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Jaehak; Yoo, Myoung-Woo; Kim, Sang-Koog, E-mail: sangkoog@snu.ac.kr
We report on a micromagnetic simulation study of interactions between propagating spin waves and a head-to-head domain wall in geometrically confined magnetic nanotubes. We found that incident spin waves of specific frequencies can lead to sufficiently high-speed (on the order of a few hundreds of m/s or higher) domain-wall motions in the same direction as that of the incident spin-waves. The domain-wall motions and their speed vary remarkably with the frequency and the amplitude of the incident spin-waves. High-speed domain-wall motions originate from the transfer torque of spin waves' linear momentum to the domain wall, through the partial or completemore » reflection of the incident spin waves from the domain wall. This work provides a fundamental understanding of the interaction of the spin waves with a domain wall in the magnetic nanotubes as well as a route to all-magnetic control of domain-wall motions in the magnetic nanoelements.« less
Bounded Kalman filter method for motion-robust, non-contact heart rate estimation
Prakash, Sakthi Kumar Arul; Tucker, Conrad S.
2018-01-01
The authors of this work present a real-time measurement of heart rate across different lighting conditions and motion categories. This is an advancement over existing remote Photo Plethysmography (rPPG) methods that require a static, controlled environment for heart rate detection, making them impractical for real-world scenarios wherein a patient may be in motion, or remotely connected to a healthcare provider through telehealth technologies. The algorithm aims to minimize motion artifacts such as blurring and noise due to head movements (uniform, random) by employing i) a blur identification and denoising algorithm for each frame and ii) a bounded Kalman filter technique for motion estimation and feature tracking. A case study is presented that demonstrates the feasibility of the algorithm in non-contact estimation of the pulse rate of subjects performing everyday head and body movements. The method in this paper outperforms state of the art rPPG methods in heart rate detection, as revealed by the benchmarked results. PMID:29552419
Angelaki, Dora E
2017-01-01
Brainstem and cerebellar neurons implement an internal model to accurately estimate self-motion during externally generated (‘passive’) movements. However, these neurons show reduced responses during self-generated (‘active’) movements, indicating that predicted sensory consequences of motor commands cancel sensory signals. Remarkably, the computational processes underlying sensory prediction during active motion and their relationship to internal model computations during passive movements remain unknown. We construct a Kalman filter that incorporates motor commands into a previously established model of optimal passive self-motion estimation. The simulated sensory error and feedback signals match experimentally measured neuronal responses during active and passive head and trunk rotations and translations. We conclude that a single sensory internal model can combine motor commands with vestibular and proprioceptive signals optimally. Thus, although neurons carrying sensory prediction error or feedback signals show attenuated modulation, the sensory cues and internal model are both engaged and critically important for accurate self-motion estimation during active head movements. PMID:29043978
Rahman, Md Arifur; Al Mamun, Abdullah; Yao, Kui
2015-08-01
The head positioning servo system in hard disk drive is implemented nowadays using a dual-stage actuator—the primary stage consisting of a voice coil motor actuator providing long range motion and the secondary stage controlling the position of the read/write head with fine resolution. Piezoelectric micro-actuator made of lead zirconate titanate (PZT) has been a popular choice for the secondary stage. However, PZT micro-actuator exhibits hysteresis—an inherent nonlinear characteristic of piezoelectric material. The advantage expected from using the secondary micro-actuator is somewhat lost by the hysteresis of the micro-actuator that contributes to tracking error. Hysteresis nonlinearity adversely affects the performance and, if not compensated, may cause inaccuracy and oscillation in the response. Compensation of hysteresis is therefore an important aspect for designing head-positioning servo system. This paper presents a new rate dependent model of hysteresis along with rigorous analysis and identification of the model. Parameters of the model are found using particle swarm optimization. Direct inverse of the proposed rate-dependent generalized Prandtl-Ishlinskii model is used as the hysteresis compensator. Effectiveness of the overall solution is underscored through experimental results.
Three-dimensional analysis of cervical spine segmental motion in rotation.
Zhao, Xiong; Wu, Zi-Xiang; Han, Bao-Jun; Yan, Ya-Bo; Zhang, Yang; Lei, Wei
2013-06-20
The movements of the cervical spine during head rotation are too complicated to measure using conventional radiography or computed tomography (CT) techniques. In this study, we measure three-dimensional segmental motion of cervical spine rotation in vivo using a non-invasive measurement technique. Sixteen healthy volunteers underwent three-dimensional CT of the cervical spine during head rotation. Occiput (Oc) - T1 reconstructions were created of volunteers in each of 3 positions: supine and maximum left and right rotations of the head with respect to the bosom. Segmental motions were calculated using Euler angles and volume merge methods in three major planes. Mean maximum axial rotation of the cervical spine to one side was 1.6° to 38.5° at each level. Coupled lateral bending opposite to lateral bending was observed in the upper cervical levels, while in the subaxial cervical levels, it was observed in the same direction as axial rotation. Coupled extension was observed in the cervical levels of C5-T1, while coupled flexion was observed in the cervical levels of Oc-C5. The three-dimensional cervical segmental motions in rotation were accurately measured with the non-invasive measure. These findings will be helpful as the basis for understanding cervical spine movement in rotation and abnormal conditions. The presented data also provide baseline segmental motions for the design of prostheses for the cervical spine.
Paralabral rupture of the proximal biceps tendon from light weightlifting.
Miller, Kyle E; Solomon, Daniel J
2008-12-01
Rupture of the long head of the biceps is usually seen in older adults, in conjunction with rotator cuff tears or tenosynovitis secondary to chronic subacromial impingement; it is rarely seen as a result of trauma. We present the case of a young active patient who denied prodromal symptoms but ruptured the long head of the biceps brachii tendon (LHB) while performing 25-pound biceps curls. Upon examination, the patient was noted to have a readily apparent biceps defect and decreased strength. He was brought to the operating room, where open subpectoral tenodesis of the LHB was performed. At the 6-week follow-up evaluation, the patient had regained full range of motion. By 6 months, he had regained his previous strength. This case demonstrates an unusual presentation of a LHB rupture in a young healthy man with no prodromal symptoms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omari, E; Noid, G; Ehlers, C
Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries ofmore » the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.« less
Bilateral avascular necrosis of the femoral head due to the use of heroin: A case report.
Ozkunt, Okan; Sarıyılmaz, Kerim; Sungur, Mustafa; Ilen, Ferhat; Dikici, Fatih
2015-01-01
Femoral head avascular necrosis is caused by disruption of the blood supply of the femoral head, which finally results in hip dysfunction. Non traumatic osteonecrosis may related with corticosteroid use, alcohol abuse, SLE, hemoglobinopathies or exposure to cytotoxic agents. But avascular necrosis of the femoral head (ANFH) due to heroin use is a rare condition. We report a patient with bilateral ANFH due to heroin use treated by simultaneous bilateral hip arthroplasty. 37 year-old male patient presented with bilateral hip pain that had been occurring for four years. The patient had no history of smoking, excessive drinking, using corticosteroid and the other drugs or trauma but used heroin for 10 years. In clinic and radiologic examination indicated advanced degenerative changes on both hip due to femoral head avascular necrosis. The patient was treated with simultaneous bilateral total hip arthroplasty. After 6 months postoperatively the active hip range of motion was painless. Avascular femoral head necrosis caused by the using of heroin is rare. Ultimately, osteonecrosis of the femoral head occurs through one final common pathway, which is decreased blood flow to the femoral head that leads bone ischemia and death. But it is still unknown that heroin's systemic effects. Intravenous drug use more as a serious problem for today. There is a need for comprehensive studies to demonstrate effects of heroin on bone and vascularity metabolism. Heroin use will be important problem for population. That's why is crucial to understand the effect of heroin. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Hefti, Fritz; Clarke, N M P
2007-03-01
The aim of the study was to find out whether or not there is consensus among experienced pediatric orthopaedists about the management of certain clinical scenarios in Legg-Calvé-Perthes' disease. A questionnaire was sent to all 297 members of the European Paediatric Orthopaedic Society (EPOS) describing four cases of Legg-Calvé-Perthes' disease (LCPD) with two X-rays each and a short description of the clinical scenario. Two of the patients were younger and two were older than six years of age. From both age groups there was one with a good range of motion and an X-ray classified as Herring A or B, while the other patient had a poor range of motion and an X-ray classified as Herring C. EPO members were asked to choose from various treatment options or to describe any other therapy that they would advise in the clinical scenarios. One-hundred and fifty members answered the questionnaire. The participants had an average of 20 years of experience in pediatric orthopaedics. There was a consensus that no surgery should be performed in a young patient with a good range of motion and that there should be no weight relief when older with a good range of motion. Conservative containment treatment (abduction splint, Petrie cast) and arthrodiastasis was suggested in only very few centres. There was a tendency to perform an operation when the patient is older with a poor range of motion and to perform operative treatment only when there were subluxation or head at risk signs. pelvic osteotomies or a combination of pelvic and femoral osteotomies rather than femoral osteotomies alone. Age did not determine the indication for treatment and there was no agreement on the indications for physiotherapy. There was also no consensus on the type of pelvic osteotomy to be used. The study showed that indications for the treatment of LCPD is based more on the personal experience of the surgeon rather than on scientific data.
Kanada, Ryo; Kuwata, Takeshi; Kenzaki, Hiroo; Takada, Shoji
2013-01-01
Kinesin is a family of molecular motors that move unidirectionally along microtubules (MT) using ATP hydrolysis free energy. In the family, the conventional two-headed kinesin was experimentally characterized to move unidirectionally through "walking" in a hand-over-hand fashion by coordinated motions of the two heads. Interestingly a single-headed kinesin, a truncated KIF1A, still can generate a biased Brownian movement along MT, as observed by in vitro single molecule experiments. Thus, KIF1A must use a different mechanism from the conventional kinesin to achieve the unidirectional motions. Based on the energy landscape view of proteins, for the first time, we conducted a set of molecular simulations of the truncated KIF1A movements over an ATP hydrolysis cycle and found a mechanism exhibiting and enhancing stochastic forward-biased movements in a similar way to those in experiments. First, simulating stand-alone KIF1A, we did not find any biased movements, while we found that KIF1A with a large friction cargo-analog attached to the C-terminus can generate clearly biased Brownian movements upon an ATP hydrolysis cycle. The linked cargo-analog enhanced the detachment of the KIF1A from MT. Once detached, diffusion of the KIF1A head was restricted around the large cargo which was located in front of the head at the time of detachment, thus generating a forward bias of the diffusion. The cargo plays the role of a diffusional anchor, or cane, in KIF1A "walking."
Ding, Yao; Mohamed, Abdallah S R; Yang, Jinzhong; Colen, Rivka R; Frank, Steven J; Wang, Jihong; Wassal, Eslam Y; Wang, Wenjie; Kantor, Michael E; Balter, Peter A; Rosenthal, David I; Lai, Stephen Y; Hazle, John D; Fuller, Clifton D
2015-01-01
The purpose of this study was to investigate the potential of a head and neck magnetic resonance simulation and immobilization protocol on reducing motion-induced artifacts and improving positional variance for radiation therapy applications. Two groups (group 1, 17 patients; group 2, 14 patients) of patients with head and neck cancer were included under a prospective, institutional review board-approved protocol and signed informed consent. A 3.0-T magnetic resonance imaging (MRI) scanner was used for anatomic and dynamic contrast-enhanced acquisitions with standard diagnostic MRI setup for group 1 and radiation therapy immobilization devices for group 2 patients. The impact of magnetic resonance simulation/immobilization was evaluated qualitatively by 2 observers in terms of motion artifacts and positional reproducibility and quantitatively using 3-dimensional deformable registration to track intrascan maximum motion displacement of voxels inside 7 manually segmented regions of interest. The image quality of group 2 (29 examinations) was significantly better than that of group 1 (50 examinations) as rated by both observers in terms of motion minimization and imaging reproducibility (P < .0001). The greatest average maximum displacement was at the region of the larynx in the posterior direction for patients in group 1 (17 mm; standard deviation, 8.6 mm), whereas the smallest average maximum displacement was at the region of the posterior fossa in the superior direction for patients in group 2 (0.4 mm; standard deviation, 0.18 mm). Compared with group 1, maximum regional motion was reduced in group 2 patients in the oral cavity, floor of mouth, oropharynx, and larynx regions; however, the motion reduction reached statistical significance only in the regions of the oral cavity and floor of mouth (P < .0001). The image quality of head and neck MRI in terms of motion-related artifacts and positional reproducibility was greatly improved by use of radiation therapy immobilization devices. Consequently, immobilization with external and intraoral fixation in MRI examinations is required for radiation therapy application. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Motion sickness elicited by passive rotation in squirrel monkeys
NASA Technical Reports Server (NTRS)
Daunton, Nancy G.; Fox, Robert A.
1991-01-01
Current theory and recent evidence suggest that motion sickness occurs under conditions of sensory input in which the normal motor programs for producing eye, head, and body movements are not functionally effective, i.e. under conditions in which there are difficulties in maintaining posture and controlling eye movements. Conditions involving conflicting or inconsistent visual-vestibular (VV) stimulation should thus result in greater sickness rates since the existing motor programs do not produce effective control of eye-head-body movements under such conditions. It is felt that the relationship of postural control to motion sickness is an important one and one often overlooked. The results are reported which showed that when postural requirements were minimized by fully restraining squirrel monkeys during hypogravity parabolic flight, no animals became motion sick, but over 80 percent of the same 11 animals became sick if they were unrestrained and maintained control of their posture.
Coordinates of Human Visual and Inertial Heading Perception.
Crane, Benjamin Thomas
2015-01-01
Heading estimation involves both inertial and visual cues. Inertial motion is sensed by the labyrinth, somatic sensation by the body, and optic flow by the retina. Because the eye and head are mobile these stimuli are sensed relative to different reference frames and it remains unclear if a perception occurs in a common reference frame. Recent neurophysiologic evidence has suggested the reference frames remain separate even at higher levels of processing but has not addressed the resulting perception. Seven human subjects experienced a 2s, 16 cm/s translation and/or a visual stimulus corresponding with this translation. For each condition 72 stimuli (360° in 5° increments) were delivered in random order. After each stimulus the subject identified the perceived heading using a mechanical dial. Some trial blocks included interleaved conditions in which the influence of ±28° of gaze and/or head position were examined. The observations were fit using a two degree-of-freedom population vector decoder (PVD) model which considered the relative sensitivity to lateral motion and coordinate system offset. For visual stimuli gaze shifts caused shifts in perceived head estimates in the direction opposite the gaze shift in all subjects. These perceptual shifts averaged 13 ± 2° for eye only gaze shifts and 17 ± 2° for eye-head gaze shifts. This finding indicates visual headings are biased towards retina coordinates. Similar gaze and head direction shifts prior to inertial headings had no significant influence on heading direction. Thus inertial headings are perceived in body-centered coordinates. Combined visual and inertial stimuli yielded intermediate results.
Coordinates of Human Visual and Inertial Heading Perception
Crane, Benjamin Thomas
2015-01-01
Heading estimation involves both inertial and visual cues. Inertial motion is sensed by the labyrinth, somatic sensation by the body, and optic flow by the retina. Because the eye and head are mobile these stimuli are sensed relative to different reference frames and it remains unclear if a perception occurs in a common reference frame. Recent neurophysiologic evidence has suggested the reference frames remain separate even at higher levels of processing but has not addressed the resulting perception. Seven human subjects experienced a 2s, 16 cm/s translation and/or a visual stimulus corresponding with this translation. For each condition 72 stimuli (360° in 5° increments) were delivered in random order. After each stimulus the subject identified the perceived heading using a mechanical dial. Some trial blocks included interleaved conditions in which the influence of ±28° of gaze and/or head position were examined. The observations were fit using a two degree-of-freedom population vector decoder (PVD) model which considered the relative sensitivity to lateral motion and coordinate system offset. For visual stimuli gaze shifts caused shifts in perceived head estimates in the direction opposite the gaze shift in all subjects. These perceptual shifts averaged 13 ± 2° for eye only gaze shifts and 17 ± 2° for eye-head gaze shifts. This finding indicates visual headings are biased towards retina coordinates. Similar gaze and head direction shifts prior to inertial headings had no significant influence on heading direction. Thus inertial headings are perceived in body-centered coordinates. Combined visual and inertial stimuli yielded intermediate results. PMID:26267865
NASA Astrophysics Data System (ADS)
Wang, Po-Jen; Keyawa, Nicholas R.; Euler, Craig
2012-01-01
In order to achieve highly accurate motion control and path planning for a mobile robot, an obstacle avoidance algorithm that provided a desired instantaneous turning radius and velocity was generated. This type of obstacle avoidance algorithm, which has been implemented in California State University Northridge's Intelligent Ground Vehicle (IGV), is known as Radial Polar Histogram (RPH). The RPH algorithm utilizes raw data in the form of a polar histogram that is read from a Laser Range Finder (LRF) and a camera. A desired open block is determined from the raw data utilizing a navigational heading and an elliptical approximation. The left and right most radii are determined from the calculated edges of the open block and provide the range of possible radial paths the IGV can travel through. In addition, the calculated obstacle edge positions allow the IGV to recognize complex obstacle arrangements and to slow down accordingly. A radial path optimization function calculates the best radial path between the left and right most radii and is sent to motion control for speed determination. Overall, the RPH algorithm allows the IGV to autonomously travel at average speeds of 3mph while avoiding all obstacles, with a processing time of approximately 10ms.
Binocular Interactions Underlying the Classic Optomotor Responses of Flying Flies
Duistermars, Brian J.; Care, Rachel A.; Frye, Mark A.
2012-01-01
In response to imposed course deviations, the optomotor reactions of animals reduce motion blur and facilitate the maintenance of stable body posture. In flies, many anatomical and electrophysiological studies suggest that disparate motion cues stimulating the left and right eyes are not processed in isolation but rather are integrated in the brain to produce a cohesive panoramic percept. To investigate the strength of such inter-ocular interactions and their role in compensatory sensory–motor transformations, we utilize a virtual reality flight simulator to record wing and head optomotor reactions by tethered flying flies in response to imposed binocular rotation and monocular front-to-back and back-to-front motion. Within a narrow range of stimulus parameters that generates large contrast insensitive optomotor responses to binocular rotation, we find that responses to monocular front-to-back motion are larger than those to panoramic rotation, but are contrast sensitive. Conversely, responses to monocular back-to-front motion are slower than those to rotation and peak at the lowest tested contrast. Together our results suggest that optomotor responses to binocular rotation result from the influence of non-additive contralateral inhibitory as well as excitatory circuit interactions that serve to confer contrast insensitivity to flight behaviors influenced by rotatory optic flow. PMID:22375108
Branson, B G; Abnos, R M; Simmer-Beck, M L; King, G W; Siddicky, S F
2018-01-01
Motion analysis has great potential for quantitatively evaluating dental operator posture and the impact of interventions such as magnification loupes on posture and subsequent development of musculoskeletal disorders. This study sought to determine the feasibility of motion capture technology for measurement of dental operator posture and examine the impact that different styles of magnification loupes had on dental operator posture. Forward and lateral head flexion were measured for two different operators while completing a periodontal probing procedure. Each was measured while wearing magnification loupes (flip up-FL and through the lens-TTL) and basic safety lenses. Operators both exhibited reduced forward flexion range of motion (ROM) when using loupes (TTL or FL) compared to a baseline lens (BL). In contrast to forward flexion, no consistent trends were observed for lateral flexion between subjects. The researchers can report that it is possible to measure dental operator posture using motion capture technology. More study is needed to determine which type of magnification loupes (FL or TTL) are superior in improving dental operator posture. Some evidence was found supporting that the quality of operator posture may more likely be related to the use of magnification loupes, rather than the specific type of lenses worn.
Note: Compact and light displacement sensor for a precision measurement system in large motion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Sang Heon, E-mail: shlee@andong.ac.kr
We developed a compact and light displacement sensor applicable to systems that require wide range motions of its sensing device. The proposed sensor utilized the optical pickup unit of the optical disk drive, which has been used applied to atomic force microscopy (AFM) because of its compactness and lightness as well as its high performance. We modified the structure of optical pickup unit and made the compact sensor driver attachable to a probe head of AFM to make large rotation. The feasibilities of the developed sensor for a general probe-moving measurement device and for probe-rotating AFM were verified. Moreover, amore » simple and precise measurement of alignment between centers of rotator and probe tip in probe-rotation AFM was experimentally demonstrated using the developed sensor.« less
Measurement of the Three-Dimensional Vibration Motion of the Ossicular Chain in the Living Gerbil
NASA Astrophysics Data System (ADS)
Decraemer, Willem F.; de La Rochefoucauld, Ombeline; Olson, Elizabeth S.
2011-11-01
In previous studies 3D motion of the middle-ear ossicles in cat and human temporal bone were explored but models for hearing research has shifted in the last decades to smaller mammals and gerbil in particular has become a hearing model of first choice. In the present study we have measured with an optical interferometer the 3D motion of the malleus and incus in anesthetized gerbil for sound of moderate intensity (90 dB SPL) in a broad frequency range. To access the malleus and incus the pars flaccida was completely removed exposing the neck and head of the malleus and the incus from the malleus-incus joint to the long process of the incus and the plate of the lenticular process. In a previous study an approach through a hole in the bullar wall was used to study the stapes motion so that we now have a complete picture of the middle ear motion. In both approaches vibration measurements were done at 6 to 7 points per ossicle while the angle of observation was varied over approximately 30 degrees to enable calculation of the 3D velocity components. Knowledge of middle ear motion is of great importance in understanding how the middle ear transforms the acoustical input from the ear canal to the cochlea.
NASA Technical Reports Server (NTRS)
Richards, J. T.; Mulavara, A. P.; Ruttley, T.; Peters, B. T.; Warren, L. E.; Bloomberg, J. J.
2006-01-01
We have previously shown that viewing simulated rotary self-motion during treadmill locomotion causes adaptive modification of the control of position and trajectory during over-ground locomotion, which functionally reflects adaptive changes in the sensorimotor integration of visual, vestibular, and proprioceptive cues (Mulavara et al., 2005). The objective of this study was to investigate how strategic changes in torso control during exposure to simulated rotary self-motion during treadmill walking influences adaptive modification of locomotor heading direction during over-ground stepping.
Dynamics of squirrel monkey linear vestibuloocular reflex and interactions with fixation distance.
Telford, L; Seidman, S H; Paige, G D
1997-10-01
Horizontal, vertical, and torsional eye movements were recorded using the magnetic search-coil technique during linear accelerations along the interaural (IA) and dorsoventral (DV) head axes. Four squirrel monkeys were translated sinusoidally over a range of frequencies (0.5-4.0 Hz) and amplitudes (0.1-0.7 g peak acceleration). The linear vestibuloocular reflex (LVOR) was recorded in darkness after brief presentations of visual targets at various distances from the subject. With subjects positioned upright or nose-up relative to gravity, IA translations generated conjugate horizontal (IA horizontal) eye movements, whereas DV translations with the head nose-up or right-side down generated conjugate vertical (DV vertical) responses. Both were compensatory for linear head motion and are thus translational LVOR responses. In concert with geometric requirements, both IA-horizontal and DV-vertical response sensitivities (in deg eye rotation/cm head translation) were related linearly to reciprocal fixation distance as measured by vergence (in m-1, or meter-angles, MA). The relationship was characterized by linear regressions, yielding sensitivity slopes (in deg.cm-1.MA-1) and intercepts (sensitivity at 0 vergence). Sensitivity slopes were greatest at 4.0 Hz, but were only slightly more than half the ideal required to maintain fixation. Slopes declined with decreasing frequency, becoming negligible at 0.5 Hz. Small responses were observed when vergence was zero (intercept), although no response is required. Like sensitivity slope, the intercept was largest at 4.0 Hz and declined with decreasing frequency. Phase lead was near zero (compensatory) at 4.0 Hz, but increased as frequency declined. Changes in head orientation, motion axis (IA vs. DV), and acceleration amplitude produced slight and sporadic changes in LVOR parameters. Translational LVOR response characteristics are consistent with high-pass filtering within LVOR pathways. Along with horizontal eye movements, IA translation generated small torsional responses. In contrast to the translational LVORs, IA-torsional responses were not systematically modulated by vergence angle. The IA-torsional LVOR is not compensatory for translation because it cannot maintain image stability. Rather, it likely compensates for the effective head tilt simulated by translation. When analyzed in terms of effective head tilt, torsional responses were greatest at the lowest frequency and declined as frequency increased, consistent with low-pass filtering of otolith input. It is unlikely that IA-torsional responses compensate for actual head tilt, however, because they were similar for both upright and nose-up head orientations. The IA-torsional and -horizontal LVORs seem to respond only to linear acceleration along the IA head axis, and the DV-vertical LVOR to acceleration along the head's DV axis, regardless of gravity.
Kim, Jongshin; Nam, Kyoung Won; Jang, Ik Gyu; Yang, Hee Kyung; Kim, Kwang Gi; Hwang, Jeong-Min
2012-03-15
To evaluate the accuracy, validity, and reliability of a newly developed infrared optical head tracker (IOHT) using Nintendo Wii remote controllers (WiiMote; Nintendo Co. Ltd., Kyoto, Japan) for measurement of the angle of head posture. The IOHT consists of two infrared (IR) receivers (WiiMote) that are fixed to a mechanical frame and connected to a monitoring computer via a Bluetooth communication channel and an IR beacon that consists of four IR light-emitting diodes (LEDs). With the use of the Cervical Range of Motion (CROM; Performance Attainment Associates, St. Paul, MN) as a reference, one- and three-dimensional (1- and 3-D) head postures of 20 normal adult subjects (20-37 years of age; 9 women and 11 men) were recorded with the IOHT. In comparison with the data from the CROM, the IOHT-derived results showed high consistency. The measurements of 1- and 3-D positions of the human head with the IOHT were very close to those of the CROM. The correlation coefficients of 1- and 3-D positions between the IOHT and the CROM were more than 0.99 and 0.96 (P < 0.05, Pearson's correlation test), respectively. Reliability tests of the IOHT for the normal adult subjects for 1- and 3-D positions of the human head had 95% limits of agreement angles of approximately ±4.5° and ±8.0°, respectively. The IOHT showed strong concordance with the CROM and relatively good test-retest reliability, thus proving its validity and reliability as a head-posture-measuring device. Considering its high performance, ease of use, and low cost, the IOHT has the potential to be widely used as a head-posture-measuring device in clinical practice.
Qian, Zhi-Ming; Wang, Shuo Hong; Cheng, Xi En; Chen, Yan Qiu
2016-06-23
Fish tracking is an important step for video based analysis of fish behavior. Due to severe body deformation and mutual occlusion of multiple swimming fish, accurate and robust fish tracking from video image sequence is a highly challenging problem. The current tracking methods based on motion information are not accurate and robust enough to track the waving body and handle occlusion. In order to better overcome these problems, we propose a multiple fish tracking method based on fish head detection. The shape and gray scale characteristics of the fish image are employed to locate the fish head position. For each detected fish head, we utilize the gray distribution of the head region to estimate the fish head direction. Both the position and direction information from fish detection are then combined to build a cost function of fish swimming. Based on the cost function, global optimization method can be applied to associate the target between consecutive frames. Results show that our method can accurately detect the position and direction information of fish head, and has a good tracking performance for dozens of fish. The proposed method can successfully obtain the motion trajectories for dozens of fish so as to provide more precise data to accommodate systematic analysis of fish behavior.
Measurement of flow inside a vacuum cleaner head
NASA Astrophysics Data System (ADS)
Iguchi, Ryotaro; Ban, Hisataka; Sakakibara, Jun
2017-11-01
Vacuum cleaner head with rotating brushes is widely used as a home appliance. Although it efficiently collects dusts from the floor, flow field of the air and motion of the dust inside the head have not been fully investigated. In this study, we performed 3D-PIV (particle tracking velocimetry) measurement of velocity field inside the head. Water was used as working fluid, which allows a use of fluorescent particle to reduce unwanted reflection from the brushes and inner surface of the head. Mean velocity field and turbulence statistics in the head with and without the brush will be presented.
Hammoud, Sommer; Bedi, Asheesh; Voos, James E; Mauro, Craig S; Kelly, Bryan T
2014-03-01
In active individuals with femoroacetabular impingement (FAI), the resultant reduction in functional range of motion leads to high impaction loads at terminal ranges. These increased forces result in compensatory effects on bony and soft tissue structures within the hip joint and hemipelvis. An algorithm is useful in evaluating athletes with pre-arthritic, mechanical hip pain and associated compensatory disorders. A literature search was performed by a review of PubMed articles published from 1976 to 2013. Level 4. Increased stresses across the bony hemipelvis result when athletes with FAI attempt to achieve supraphysiologic, terminal ranges of motion (ROM) through the hip joint required for athletic competition. This can manifest as pain within the pubic joint (osteitis pubis), sacroiliac joint, and lumbosacral spine. Subclinical posterior hip instability may result when attempts to increase hip flexion and internal rotation are not compensated for by increased motion through the hemipelvis. Prominence of the anterior inferior iliac spine (AIIS) at the level of the acetabular rim can result in impingement of the anterior hip joint capsule or iliocapsularis muscle origin against the femoral head-neck junction, resulting in a distinct form of mechanical hip impingement (AIIS subspine impingement). Iliopsoas impingement (IPI) has also been described as an etiology for anterior hip pain. IPI results in a typical 3-o'clock labral tear as well as an inflamed capsule in close proximity to the overlying iliopsoas tendon. Injury in athletic pubalgia occurs during high-energy twisting activities in which abnormal hip ROM and resultant pelvic motion lead to shearing across the pubic symphysis. Failure to recognize and address concomitant compensatory injury patterns associated with intra-articular hip pathology can result in significant disability and persistent symptoms in athletes with pre-arthritic, mechanical hip pain. B.
Friction measurement in a hip wear simulator.
Saikko, Vesa
2016-05-01
A torque measurement system was added to a widely used hip wear simulator, the biaxial rocking motion device. With the rotary transducer, the frictional torque about the drive axis of the biaxial rocking motion mechanism was measured. The principle of measuring the torque about the vertical axis above the prosthetic joint, used earlier in commercial biaxial rocking motion simulators, was shown to sense only a minor part of the total frictional torque. With the present method, the total frictional torque of the prosthetic hip was measured. This was shown to consist of the torques about the vertical axis above the joint and about the leaning axis. Femoral heads made from different materials were run against conventional and crosslinked polyethylene acetabular cups in serum lubrication. Regarding the femoral head material and the type of polyethylene, there were no categorical differences in frictional torque with the exception of zirconia heads, with which the lowest values were obtained. Diamond-like carbon coating of the CoCr femoral head did not reduce friction. The friction factor was found to always decrease with increasing load. High wear could increase the frictional torque by 75%. With the present system, friction can be continuously recorded during long wear tests, so the effect of wear on friction with different prosthetic hips can be evaluated. © IMechE 2016.
Szatmary, J; Hadani, I; Julesz, B
1997-01-01
Rogers and Graham (1979) developed a system to show that head-movement-contingent motion parallax produces monocular depth perception in random dot patterns. Their display system comprised an oscilloscope driven by function generators or a special graphics board that triggered the X and Y deflection of the raster scan signal. Replication of this system required costly hardware that is no longer on the market. In this paper the Rogers-Graham method is reproduced with an Intel processor based IBM PC compatible machine with no additional hardware cost. An adapted joystick sampled through the standard game-port can serve as a provisional head-movement sensor. Monitor resolution for displaying motion is effectively enhanced 16 times by the use of anti-aliasing, enabling the display of thousands of random dots in real-time with a refresh rate of 60 Hz or above. A color monitor enables the use of the anaglyph method, thus combining stereoscopic and monocular parallax on a single display without the loss of speed. The power of this system is demonstrated by a psychophysical measurement in which subjects nulled head-movement-contingent illusory parallax, evoked by a static stereogram, with real parallax. The amount of real parallax required to null the illusory stereoscopic parallax monotonically increased with disparity.
A Study of the Response of the Human Cadaver Head to Impact
Hardy, Warren N.; Mason, Matthew J.; Foster, Craig D.; Shah, Chirag S.; Kopacz, James M.; Yang, King H.; King, Albert I.; Bishop, Jennifer; Bey, Michael; Anderst, William; Tashman, Scott
2008-01-01
High-speed biplane x-ray and neutral density targets were used to examine brain displacement and deformation during impact. Relative motion, maximum principal strain, maximum shear strain, and intracranial pressure were measured in thirty-five impacts using eight human cadaver head and neck specimens. The effect of a helmet was evaluated. During impact, local brain tissue tends to keep its position and shape with respect to the inertial frame, resulting in relative motion between the brain and skull and deformation of the brain. The local brain motions tend to follow looping patterns. Similar patterns are observed for impact in different planes, with some degree of posterior-anterior and right-left symmetry. Peak coup pressure and pressure rate increase with increasing linear acceleration, but coup pressure pulse duration decreases. Peak average maximum principal strain and maximum shear are on the order of 0.09 for CFC 60 Hz data for these tests. Peak average maximum principal strain and maximum shear increase with increasing linear acceleration, coup pressure, and coup pressure rate. Linear and angular acceleration of the head are reduced with use of a helmet, but strain increases. These results can be used for the validation of finite element models of the human head. PMID:18278591
NASA Technical Reports Server (NTRS)
Buccello, Regina R.; Cromwell, Ronita L.; Bloomberg, Jacob J.
2008-01-01
Falling is a main contributor of injury in older adults. The decline in sensory systems associated with aging limits information needed to successfully compensate for unexpected perturbations. Therefore, sensory changes result in older adults having problems maintaining balance stability when experiencing an unexpected lateral perturbation (e.g. slip) in the environment. The goal of this study was to determine head stability movement strategies used by older adults when experiencing an unexpected lateral perturbation during walking. A total of 16 healthy adults, aged 66-81 years, walked across a foam pathway 6 times. One piece of the foam pathway covered a movable platform that translated to the left when the subject stepped on the foam. Three trials were randomized in which the platform shifted. Angular rate sensors were placed on the center of mass for the head and trunk segments to collect head and trunk movement in all three planes of motion. The predominant movement strategies for maintaining head stability were determined from the results of the cross-correlation analyses between the head and trunk segments. The Chi square test of independence was used to evaluate the movement pattern distributions of head-trunk coordination during perturbed and non-perturbed walking. When perturbed, head stabilization was significantly challenged in the yaw and roll planes of motion. Subjects demonstrated a movement pattern of the head leading the trunk in an effort to stabilize the head. The older adult subjects used this head stabilization movement pattern to compensate for sensory changes when experiencing the unexpected lateral perturbation.
Head-bobbing behavior in foraging Whooping Cranes
Cronin, T.; Kinloch, M.; Olsen, Glenn H.
2006-01-01
Many species of cursorial birds 'head-bob', that is, they alternately thrust the head forward, then hold it stiII as they walk. Such a motion stabilizes visual fields intermittently and could be critical for visual search; yet the time available for stabilization vs. forward thrust varies with walking speed. Whooping Cranes (Grus americana) are extremely tall birds that visually search the ground for seeds, berries, and small prey. We examined head movements in unrestrained Whooping Cranes using digital video subsequently analyzed with a computer graphical overlay. When foraging, the cranes walk at speeds that allow the head to be held still for at least 50% of the time. This behavior is thought to balance the two needs for covering as much ground as possible and for maximizing the time for visual fixation of the ground in the search for prey. Our results strongly suggest that in cranes, and probably many other bird species, visual fixation of the ground is required for object detection and identification. The thrust phase of the head-bobbing cycle is probably also important for vision. As the head moves forward, the movement generates visual flow and motion parallax, providing visual cues for distances and the relative locations of objects. The eyes commonly change their point of fixation when the head is moving too, suggesting that they remain visually competent throughout the entire cycle of thrust and stabilization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omari, E; Erickson, B; Li, X
2015-06-15
Purpose: As it is generally difficult to outline the pancreas on an ultrasound b-mode image, visualized structures such as the portal or the splenic veins are assumed to have the same motion as the pancreas. These structures can be used as a surrogate for monitoring pancreas motion during radiation therapy (RT) delivery using ultrasound. To verify this assumption, we studied the motion difference between the head of the pancreas, the portal vein, the tail of the pancreas, and splenic vein. Methods: 4DCT data acquired during RT simulation were analyzed for a total of 5 randomly selected patients with pancreatic cancer.more » The data was sorted into 10 respiratory phases from 0% to 90% (0%: end of the inspiration, 50%: end of expiration) . The head of the pancreas (HP), tail of the pancreas (TP), portal vein (PV), and splenic vein (SV) were contoured on all 10 phases. The volume change and motion were measured in the left-right (LR), anterior-superior (AP), and superior-inferior (SI) directions. Results: The volume change for all patients/phases were: 1.2 ± 3% for HP, 0.78 ± 1.6% for PV, 2.5 ± 2.9% for TP, and 0.53 ± 2.1% for SV. Motion for each structure was estimated from the centroid displacements due to the uniformity of the structures and the small volume change. The measured motion between HP and PV was: LR: 0.1 ± 0.17 mm, AP: 0.04 ± 0.1 mm, SI: 0.17 ± 0.16 mm and between TP and the PV was: LR: 0.05 ± 0.3 mm, AP: 0.1 ± 0.4 mm, SI: 0.01 ± 0.022 mm. Conclusion: There are small motion differences between the portal vein and the head of the pancreas, and the splenic vein and the tail of the pancreas. This suggests the feasibility of utilizing these features for monitoring the pancreas motion during radiation therapy.« less
[Avascular necrosis of the femoral head in a patient with severe aplastic anaemia].
Plichta, Piotr; Pawelec, Katarzyna
2011-01-01
Avascular necrosis (AVN) is a pathological condition associated with numerous processes. Most frequent causes of ischaemia of the femoral head include trauma, corticosteroid therapy, radiation therapy, alcoholism, Gaucher's disease, systemic lupus erythematosus, rheumatoid arthritis. Corticosteroid therapy is considered the most frequent risk factor for developing avascular necrosis. In this paper we report a case of a 19-year old female patient who developed avascular necrosis of the right femoral head following treatment of severe aplastic anaemia. Clinical symptoms included groin pain and fever, painful abduction and internal rotation, tenderness over the right hip joint. The plain X-ray was not specific. However magnetic resonance imaging of the hip revealed changes characteristic for avascular necrosis. Conservative treatment was administrated. Two years after the onset of first clinical symptoms the patient is able to walk without pain, although the range of motion of the right hip joint is partially diminished. We evaluated the possible risk factors of AVN, diagnostic methods and prognosis. The onset of avascular necrosis should be considered as one of the relevant complications in patients with severe aplastic anaemia following immunosuppressive treatment.
Gunshot-wound dynamics model for John F. Kennedy assassination.
Nalli, Nicholas R
2018-04-01
U.S. President John F. Kennedy was assassinated while riding in an open motorcade by a sniper in Dallas, Texas on 22 November 1963. A civilian bystander, Mr. Abraham Zapruder, filmed the motorcade with a 8-mm home movie camera as it drove through Dealey Plaza, inadvertently recording an ≈8 second sequence of events that included a fatal gunshot wound to the President in the head. The accompanying backward motion of the President's head after impact appeared to support later "conspiracy theories" because it was claimed that this was proof of a shot from the front (in addition to one from behind). In this paper, simple one-dimensional dynamical models are uniquely applied to study in detail the fatal shot and the motion of the President's head observed in the film. Using known parameters from the crime scene, explicit force calculations are carried out for determining the projectile's retardation during tissue passage along with the resulting transfer of momentum and kinetic energy (KE). The computed instantaneous KE transfer within the soft tissue is found to be consistent with the formation of a temporary cavity associated with the observed explosion of the head, and subsequent quantitative examination of this phenomenon reveals two delayed forces at play in the backward motion of the President following impact. It is therefore found that the observed motions of President Kennedy in the film are physically consistent with a high-speed projectile impact from the rear of the motorcade, these resulting from an instantaneous forward impulse force, followed by delayed rearward recoil and neuromuscular forces.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary
Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared headmore » position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS.« less
Peltier, Kevin E; McGarry, Michelle H; Tibone, James E; Lee, Thay Q
2012-07-01
Arthroscopic repair techniques for anterior instability most commonly address only the anterior band of the inferior glenohumeral ligament. This study quantitatively evaluated and compared the combined anterior and posterior arthroscopic plication by repairing both the anterior and posterior bands of the inferior glenohumeral ligament with the anterior arthroscopic plication alone. Six cadaveric shoulders were tested in 60° of glenohumeral abduction with 22 N of compressive force in the coronal plane for intact, after anterior capsular stretching, after anterior repair, and after posterior arthroscopic repair. Range of motion, glenohumeral translation, and glenohumeral kinematics throughout the rotational range of motion were measured with a MicroScribe 3DLX (Immersion, San Jose, CA, USA). Glenohumeral contact pressure and area were measured with a pressure measurement system (Tekscan Inc, South Boston, MA, USA). Stretching the anterior capsule significantly increased external rotation and anterior translation (P < .05). After anterior plication, external rotation was restored to the intact condition, and anterior translation was significantly decreased compared with stretched condition (P < .05). The combined anterior and posterior plication significantly decreased internal rotation compared with the intact condition. The anterior plication shifted the humeral head posterior in external rotation, whereas the combined anterior and posterior plication shifted the humeral head anterior in internal rotation (P < .05). Both repairs led to a decrease in glenohumeral contact area at 45° external rotation (P < .07). The addition of a posterior plication to anterior plication for anterior instability has no biomechanical advantage over a typical arthroscopic anterior repair for anterior glenohumeral instability. Published by Mosby, Inc.
Prehospital emergency removal of football helmets using two techniques.
Swartz, Erik E; Hernandez, Adam E; Decoster, Laura C; Mihalik, Jason P; Burns, Matthew F; Reynolds, Cathryn
2011-01-01
To compare the Eject Helmet Removal (EHR) System with manual football helmet removal. This quasiexperimental counterbalanced study was conducted in a controlled laboratory setting. Thirty certified athletic trainers (17 men and 13 women; mean ± standard deviation age: 33.03 ± 10.02 years; height: 174.53 ± 12.04 cm; mass: 85.19 ± 19.84 kg) participated after providing informed consent. Participants removed a Riddell Revolution IQ football helmet from a healthy model two times each under two conditions: manual helmet removal (MHR) and removal with the EHR system. A six-camera, three-dimensional motion capture system was used to record range of motion (ROM) of the head. A digital stopwatch was used to time trials and to record a split time associated with EHR system bladder insertion. A modified Borg CR10 scale was used to measure the rating of perceived exertion (RPE). Mean values were created for each variable. Three pairwise t-tests with Bonferroni-corrected alpha levels tested for differences between time for removal, split time, and RPE. A 2 x 3 (condition x plane) totally within-subjects repeated-measures design analysis of variance (ANOVA) tested for differences in head ROM between the sagittal, frontal, and transverse planes. Analyses were performed using SPSS (version 18.0) (alpha = 0.05). There was no statistically significant difference in perceived difficulty between EHR (RPE = 2.73) and MHR (RPE = 2.55) (t(29) = 0.76; p = 0.45; d = 0.20). Manual helmet removal was, on average, 28.95 seconds faster than EHR (t(29) = 11.44; p < 0.001). Head ROM was greater during EHR compared with MHR in the sagittal (t(29) = 4.57; p < 0.001), frontal (t(29) = 5.90; p < 0.001), and transverse (t(29) = 8.34; p < 0.001) planes. Head ROM was also greater during the helmet-removal portion of EHR in the frontal (t(29) = 4.44; p < 0.001) and transverse (t(29) = 5.99; p < 0.001) planes, compared with MHR. Regardless of technique, sagittal-plane head ROM was greater than frontal- and transverse-plane movements (F(2,58) = 241.47; p < 0.001). Removing a helmet manually is faster and creates slightly less motion than removing a helmet using the Eject system. Both techniques were equally easy to use. Future research should analyze the performance of the Eject system in other styles of football helmets and in helmets used in other sports such as lacrosse, motorsports, and ice hockey.
Yamane, Shihori; Kyomoto, Masayuki; Moro, Toru; Hashimoto, Masami; Takatori, Yoshio; Tanaka, Sakae; Ishihara, Kazuhiko
2018-04-01
Younger, active patients who undergo total hip arthroplasty (THA) have increasing needs for wider range of motion and improved stability of the joint. Therefore, bearing materials having not only higher wear resistance but also mechanical strength are required. Carbon fiber-reinforced poly(ether ether ketone) (CFR-PEEK) is known as a super engineering plastic that has great mechanical strength. In this study, we focused on poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted CFR-PEEK and investigated the effects of PMPC grafting and the femoral heads materials on the wear properties of CFR-PEEK liners. Compared with untreated CFR-PEEK, the PMPC-grafted CFR-PEEK surface revealed higher wettability and lower friction properties under aqueous circumstances. In the hip simulator wear test, wear particles generated from the PMPC-grafted CFR-PEEK liners were fewer than those of the untreated CFR-PEEK liners. There were no significant differences in the size and the morphology of the wear particles between the differences of PMPC-grafting and the counter femoral heads. Zirconia-toughened alumina (ZTA) femoral heads had significantly smoother surfaces compared to cobalt-chromium-molybdenum alloy femoral heads after the hip simulator test. Thus, we conclude that the bearing combination of the PMPC-grafted CFR-PEEK liner and ZTA head is expected to be a lifelong bearing interface in THA. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1028-1037, 2018. © 2017 Wiley Periodicals, Inc.
Effects of Flexibility and Balance on Driving Distance and Club Head Speed in Collegiate Golfers.
Marshall, Kelsey J; Llewellyn, Tamra L
2017-01-01
Good balance, flexibility, and strength are all required to maintain a steady stance during the kinematic chain to produce successful golf shots. When the body can produce more power, more club head speed is generated. This formation of power translates into greater distance and accuracy. Athletes today are seeking exercise programs to enhance these qualities of their golf swing. The purpose of this study is to investigate the correlations between flexibility and balance with club head speed and driving distance in the golf swing of male and female collegiate golfers. Five male and five female collegiate golfers participated in the study. They completed multiple range of motion tests, the Balance Error System Test, and multiple flexibility tests. Subjects then participated in a short hitting session. Ten shots were hit with the subject's own driver. The Optishot simulator measured distance and club head speed generated. There was a significant negative correlation between the BESS test score and average distance for male subjects (r=-0.850, p=0.034). There were also a few trends between the balance, flexibility, and club head speed findings of both male and female subjects. This data shows there is a significant relationship between better balance and driving the ball farther. Other trends show better balance and flexibility will result in greater driving distance and club head speed. Balance and flexibility exercises should be incorporated into a golfer's practice or workout regiment.
Human ocular torsion during parabolic flights: an analysis with scleral search coil
NASA Technical Reports Server (NTRS)
Cheung, B. S.; Money, K.; Howard, I.; Kirienko, N.; Johnson, W.; Lackner, J.; Dizio, P.; Evanoff, J.
1992-01-01
Rotation of the eyes about the visual axis is known as ocular torsion. A lateral inclination (a "roll") of the head induces ocular torsion in the opposite direction, a response known as ocular counterrolling. For six subjects, we recorded the static (head still) and dynamic (head in oscillatory roll motion) ocular torsion in normal 1 g condition and also during the microgravity and hypergravity periods of parabolic flight, using the electromagnetic scleral search coil technique. With the head still, the direction and magnitude of torsion that occurred in response to microgravity and hypergravity differed substantially from one individual to another, but there was a significant difference in torsional magnitude between the microgravity and hypergravity periods, for all static head positions including the upright position. Under normal 1 g conditions, counterrolling compensated for about 16% of (voluntary) static head roll, while dynamic counterroll was much larger, up to 36% of head roll at 0.55 Hz. With increasing frequency of head oscillation between 0.33 Hz and 0.55 Hz, the gain of counterrolling increased and there was no change in the phase relationship. The gain of dynamic counterroll (in response to voluntary head rolling) was not significantly less in hypogravity, suggesting that on the ground at these frequencies the contribution of gravity and gravity receptors to this reflex is redundant: this reflex is probably driven by the semicircular canals. In some subjects, the torsional displacement in microgravity is accompanied by micro-torsional oscillatory motion.
Keyboard before Head Tracking Depresses User Success in Remote Camera Control
NASA Astrophysics Data System (ADS)
Zhu, Dingyun; Gedeon, Tom; Taylor, Ken
In remote mining, operators of complex machinery have more tasks or devices to control than they have hands. For example, operating a rock breaker requires two handed joystick control to position and fire the jackhammer, leaving the camera control to either automatic control or require the operator to switch between controls. We modelled such a teleoperated setting by performing experiments using a simple physical game analogue, being a half size table soccer game with two handles. The complex camera angles of the mining application were modelled by obscuring the direct view of the play area and the use of a Pan-Tilt-Zoom (PTZ) camera. The camera control was via either a keyboard or via head tracking using two different sets of head gestures called “head motion” and “head flicking” for turning camera motion on/off. Our results show that the head motion control was able to provide a comparable performance to using a keyboard, while head flicking was significantly worse. In addition, the sequence of use of the three control methods is highly significant. It appears that use of the keyboard first depresses successful use of the head tracking methods, with significantly better results when one of the head tracking methods was used first. Analysis of the qualitative survey data collected supports that the worst (by performance) method was disliked by participants. Surprisingly, use of that worst method as the first control method significantly enhanced performance using the other two control methods.
NASA Technical Reports Server (NTRS)
Wingrove, R. C.
1994-01-01
This program was developed by Ames Research Center, in cooperation with the National Transportation Safety Board, as a technique for deriving time histories of an aircraft's motion from Air Traffic Control (ATC) radar records. This technique uses the radar range and azimuth data, along with the downlinked altitude data, to derive an expanded set of data which includes airspeed, lift, attitude angles (pitch, roll, and heading), etc. This technique should prove useful as a source of data in the investigation of commercial airline accidents and in the analysis of accidents involving aircraft which do not have onboard data recorders (e.g., military, short-haul, and general aviation). The technique used to determine the aircraft motions involves smoothing of raw radar data. These smoothed results, in combination with other available information (wind profiles and aircraft performance data), are used to derive the expanded set of data. This program uses a cubic least-square fit to smooth the raw data. This moving-arc procedure provides a smoothed time history of the aircraft position, the inertial velocities, and accelerations. Using known winds, these inertial data are transformed to aircraft stability axes to provide true airspeed, thrust-drag, lift, and roll angle. Further derivation, based on aircraft dependent performance data, can determine the aircraft angle of attack, pitch, and heading angle. Results of experimental tests indicate that values derived from ATC radar records using this technique agree favorably with airborne measurements. This program is written in FORTRAN IV to be executed in the batch mode, and has been implemented on a CDC 6000 series computer with a central memory requirement of 64k (octal) of 60 bit words.
Regimes of plume-slab interaction and consequences for hotspot volcanism
NASA Astrophysics Data System (ADS)
Druken, Kelsey; Stegman, Dave; Kincaid, Christopher; Griffiths, Ross
2013-04-01
"Hotspot" volcanism is generally attributed to upwelling of anomalously warm mantle plumes, the intra-plate Hawaiian island chain and its simple age progression serving as an archetypal example. However, interactions of such plumes with plate margins, and in particular with subduction zones, is likely to have been a common occurrence and leads to more complicated geological records. Here we present results from a series of complementary, three-dimensional numerical and laboratory experiments that examine the dynamic interaction between negatively buoyant subducting slabs and positively buoyant mantle plumes. Slab-driven flow is shown to significantly influence the evolution and morphology of nearby plumes, which leads to a range of deformation regimes of the plume head and conduit. The success or failure of an ascending plume head to reach the lithosphere depends on the combination of plume buoyancy and position within the subduction system, where the mantle flow owing to downdip and rollback components of slab motion entrain plume material both vertically and laterally. Plumes rising within the sub-slab region tend to be suppressed by the surrounding flow field, while wedge-side plumes experience a slight enhancement before ultimately being entrained by subduction. Hotspot motion is more complex than that expected at intraplate settings and is primarily controlled by position alone. Regimes include severely deflected conduits as well as retrograde (corkscrew) motion from rollback-driven flow, often with weak and variable age-progression. The interaction styles and surface manifestations of plumes can be predicted from these models, and the results have important implications for potential hotspot evolution near convergent margins.
Subduction disfigured mantle plumes: Plumes that are not plumes?
NASA Astrophysics Data System (ADS)
Druken, K. A.; Stegman, D. R.; Kincaid, C. R.; Griffiths, R. W.
2012-12-01
"Hotspot" volcanism is generally attributed to upwelling of anomalously warm mantle plumes, the intra-plate Hawaiian island chain and its simple age progression serving as an archetypal example. However, interactions of such plumes with plate margins, and in particular with subduction zones, is likely to have been a common occurrence and leads to more complicated geological records. Here we present results from a series of complementary, three-dimensional numerical and laboratory experiments that examine the dynamic interaction between negatively buoyant subducting slabs and positively buoyant mantle plumes. Slab-driven flow is shown to significantly influence the evolution and morphology of nearby plumes, which leads to a range of deformation regimes of the plume head and conduit. The success or failure of an ascending plume head to reach the lithosphere depends on the combination of plume buoyancy and position within the subduction system, where the mantle flow owing to downdip and rollback components of slab motion entrain plume material both vertically and laterally. Plumes rising within the sub-slab region tend to be suppressed by the surrounding flow field, while wedge-side plumes experience a slight enhancement before ultimately being entrained by subduction. Hotspot motion is more complex than that expected at intraplate settings and is primarily controlled by position alone. Regimes include severely deflected conduits as well as retrograde (corkscrew) motion from rollback-driven flow, often with weak and variable age-progression. The interaction styles and surface manifestations of plumes can be predicted from these models, and the results have important implications for potential hotspot evolution near convergent margins.
Replicating and extending Bourdon's (1902) experiment on motion parallax.
Ono, Hiroshi; Lillakas, Linda; Kapoor, Anjani; Wong, Irene
2013-01-01
Bourdon conducted the first laboratory experiment on observer-produced motion parallax as a cue to depth. In three experiments, we replicated and extended Bourdon's experiment. In experiment 1, we reproduced his finding: when the two cues, motion parallax and relative height, were combined, accuracy of depth perception was high, and when the two cues were in conflict, accuracy was lower. In experiment 2, the relative height cue was replaced with relative retinal image size. As in experiment 1, when the two cues (motion parallax and relative retinal image size) were combined, accuracy was high, but when they were in conflict, it was lower. In experiment 3, the stimuli from experiments 1 and 2 were viewed monocularly with head movement and binocularly without head movement. In the binocular conditions, accuracy, certainty, and the extent of perceived depth were higher than in the monocular condition. In the conflict conditions, accuracy, certainty, and the extent of perceived depth were lower than in the no-conflict condition, but the extent of perceived motion was larger. These results are discussed in terms of recent findings about the effectiveness of motion parallax as a cue for depth.
Neural dynamics for landmark orientation and angular path integration
Seelig, Johannes D.; Jayaraman, Vivek
2015-01-01
Summary Many animals navigate using a combination of visual landmarks and path integration. In mammalian brains, head direction cells integrate these two streams of information by representing an animal's heading relative to landmarks, yet maintaining their directional tuning in darkness based on self-motion cues. Here we use two-photon calcium imaging in head-fixed flies walking on a ball in a virtual reality arena to demonstrate that landmark-based orientation and angular path integration are combined in the population responses of neurons whose dendrites tile the ellipsoid body — a toroidal structure in the center of the fly brain. The population encodes the fly's azimuth relative to its environment, tracking visual landmarks when available and relying on self-motion cues in darkness. When both visual and self-motion cues are absent, a representation of the animal's orientation is maintained in this network through persistent activity — a potential substrate for short-term memory. Several features of the population dynamics of these neurons and their circular anatomical arrangement are suggestive of ring attractors — network structures proposed to support the function of navigational brain circuits. PMID:25971509
Hydraulic modeling of unsteady debris-flow surges with solid-fluid interactions
Iverson, Richard M.
1997-01-01
Interactions of solid and fluid constituents produce the unique style of motion that typifies debris flows. To simulate this motion, a new hydraulic model represents debris flows as deforming masses of granular solids variably liquefied by viscous pore fluid. The momentum equation of the model describes how internal and boundary forces change as coarse-grained surge heads dominated by grain-contact friction grade into muddy debris-flow bodies more strongly influenced by fluid viscosity and pressure. Scaling analysis reveals that pore-pressure variations can cause flow resistance in surge heads to surpass that in debris-flow bodies by orders of magnitude. Numerical solutions of the coupled momentum and continuity equations provide good predictions of unsteady, nonuniform motion of experimental debris flows from initiation through deposition.
[Legg-Calvé-Perthes disease (LCPD). Principles of diagnosis and treatment].
Manig, M
2013-10-01
The clinical course of Legg-Calvé-Perthes disease (LCPD) is variable. Diagnosis, nonsurgical and surgical methods of treatment have evolved over many decades, from abduction casts and braces to advanced surgical containment methods which are now the mainstay of treatment. This article presents a general view and a critical evaluation of the literature. The main prognostic factors are patient age at the onset of LCPD, the range of motion and the extent of the necrotic process according to the classification of Herring and Catterall. The main aims of surgical and nonsurgical treatment of LCPD are to prevent prearthrotic deformity of the femoral head, relief of symptoms, containment of the femoral head and restoration of congruence of the hip joint. Each patient needs to be evaluated individually. Every child must receive an adapted treatment and continued follow-up at regular intervals.
Vestibular system: the many facets of a multimodal sense.
Angelaki, Dora E; Cullen, Kathleen E
2008-01-01
Elegant sensory structures in the inner ear have evolved to measure head motion. These vestibular receptors consist of highly conserved semicircular canals and otolith organs. Unlike other senses, vestibular information in the central nervous system becomes immediately multisensory and multimodal. There is no overt, readily recognizable conscious sensation from these organs, yet vestibular signals contribute to a surprising range of brain functions, from the most automatic reflexes to spatial perception and motor coordination. Critical to these diverse, multimodal functions are multiple computationally intriguing levels of processing. For example, the need for multisensory integration necessitates vestibular representations in multiple reference frames. Proprioceptive-vestibular interactions, coupled with corollary discharge of a motor plan, allow the brain to distinguish actively generated from passive head movements. Finally, nonlinear interactions between otolith and canal signals allow the vestibular system to function as an inertial sensor and contribute critically to both navigation and spatial orientation.
Autonomous Motion Planning Using a Predictive Temporal Method
2009-01-01
interception test. ......150 5-20 Target and solution path heading angles for target interception test. ..............................151 10 LIST...environment as a series of distances and angles . Regardless of the technique, this knowledge of the surrounding area is crucial for the issue of...to, the rather simplistic vector driver algorithms which compute the angle between the current vehicle heading and the heading to the goal and
NASA Technical Reports Server (NTRS)
Oman, C. M.; Lichtenberg, B. K.; Mccoy, R. K.; Money, K. E.
1986-01-01
Three cases of motion sickness that occurred on Spacelab-1 are described. The relation between head movements and symptom intensity is examined. The effects of visual, tactile, and proprioceptive orientation cues on motion sickness are studied. The effectiveness of the drugs used is evaluated and it is observed that the drugs reduce the frequency of vomiting and overall discomfort. Preflight and postflight motion sickness susceptibility data are presented.
Reliability and Normative Data for the Dynamic Visual Acuity Test for Vestibular Screening.
Riska, Kristal M; Hall, Courtney D
2016-06-01
The purpose of this study was to determine reliability of computerized dynamic visual acuity (DVA) testing and to determine reference values for younger and older adults. A primary function of the vestibular system is to maintain gaze stability during head motion. The DVA test quantifies gaze stabilization with the head moving versus stationary. Commercially available computerized systems allow clinicians to incorporate DVA into their assessment; however, information regarding reliability and normative values of these systems is sparse. Forty-six healthy adults, grouped by age, with normal vestibular function were recruited. Each participant completed computerized DVA testing including static visual acuity, minimum perception time, and DVA using the NeuroCom inVision System. Testing was performed by two examiners in the same session and then repeated at a follow-up session 3 to 14 days later. Intraclass correlation coefficients (ICCs) were used to determine inter-rater and test-retest reliability. ICCs for inter-rater reliability ranged from 0.323 to 0.937 and from 0.434 to 0.909 for horizontal and vertical head movements, respectively. ICCs for test-retest reliability ranged from 0.154 to 0.856 and from 0.377 to 0.9062 for horizontal and vertical head movements, respectively. Overall, raw scores (left/right DVA and up/down DVA) were more reliable than DVA loss scores. Reliability of a commercially available DVA system has poor-to-fair reliability for DVA loss scores. The use of a convergence paradigm and not incorporating the forced choice paradigm may contribute to poor reliability.
Shrier, Ian; Boissy, Patrick; Brière, Simon; Mellette, Jay; Fecteau, Luc; Matheson, Gordon O.; Garza, Daniel; Meeuwisse, Willem H.; Segal, Eli; Boulay, John; Steele, Russell J.
2012-01-01
Context: Health care providers must be prepared to manage all potential spine injuries as if they are unstable. Therefore, most sport teams devote resources to training for sideline cervical spine (C-spine) emergencies. Objective: To determine (1) how accurately rescuers and simulated patients can assess motion during C-spine stabilization practice and (2) whether providing performance feedback to rescuers influences their choice of stabilization technique. Design: Crossover study. Setting: Training studio. Patients or Other Participants: Athletic trainers, athletic therapists, and physiotherapists experienced at managing suspected C-spine injuries. Intervention(s): Twelve lead rescuers (at the patient's head) performed both the head-squeeze and trap-squeeze C-spine stabilization maneuvers during 4 test scenarios: lift-and-slide and log-roll placement on a spine board and confused patient trying to sit up or rotate the head. Main Outcome Measure(s): Interrater reliability between rescuer and simulated patient quality scores for subjective evaluation of C-spine stabilization during trials (0 = best, 10 = worst), correlation between rescuers' quality scores and objective measures of motion with inertial measurement units, and frequency of change in preference for the head-squeeze versus trap-squeeze maneuver. Results: Although the weighted κ value for interrater reliability was acceptable (0.71–0.74), scores varied by 2 points or more between rescuers and simulated patients for approximately 10% to 15% of trials. Rescuers' scores correlated with objective measures, but variability was large: 38% of trials scored as 0 or 1 by the rescuer involved more than 10° of motion in at least 1 direction. Feedback did not affect the preference for the lift-and-slide placement. For the log-roll placement, 6 of 8 participants who preferred the head squeeze at baseline preferred the trap squeeze after feedback. For the confused patient, 5 of 5 participants initially preferred the head squeeze but preferred the trap squeeze after feedback. Conclusions: Rescuers and simulated patients could not adequately assess performance during C-spine stabilization maneuvers without objective measures. Providing immediate feedback in this context is a promising tool for changing behavior preferences and improving training. PMID:22488229
Yuan, Jing; Yeung, David Ka Wai; Mok, Greta S. P.; Bhatia, Kunwar S.; Wang, Yi-Xiang J.; Ahuja, Anil T.; King, Ann D.
2014-01-01
Purpose To technically investigate the non-Gaussian diffusion of head and neck diffusion weighted imaging (DWI) at 3 Tesla and compare advanced non-Gaussian diffusion models, including diffusion kurtosis imaging (DKI), stretched-exponential model (SEM), intravoxel incoherent motion (IVIM) and statistical model in the patients with nasopharyngeal carcinoma (NPC). Materials and Methods After ethics approval was granted, 16 patients with NPC were examined using DWI performed at 3T employing an extended b-value range from 0 to 1500 s/mm2. DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models on primary tumor, metastatic node, spinal cord and muscle. Non-Gaussian parameter maps were generated and compared to apparent diffusion coefficient (ADC) maps in NPC. Results Diffusion in NPC exhibited non-Gaussian behavior at the extended b-value range. Non-Gaussian models achieved significantly better fitting of DWI signal than the mono-exponential model. Non-Gaussian diffusion coefficients were substantially different from mono-exponential ADC both in magnitude and histogram distribution. Conclusion Non-Gaussian diffusivity in head and neck tissues and NPC lesions could be assessed by using non-Gaussian diffusion models. Non-Gaussian DWI analysis may reveal additional tissue properties beyond ADC and holds potentials to be used as a complementary tool for NPC characterization. PMID:24466318
Self-Motion and the Shaping of Sensory Signals
Jenks, Robert A.; Vaziri, Ashkan; Boloori, Ali-Reza
2010-01-01
Sensory systems must form stable representations of the external environment in the presence of self-induced variations in sensory signals. It is also possible that the variations themselves may provide useful information about self-motion relative to the external environment. Rats have been shown to be capable of fine texture discrimination and object localization based on palpation by facial vibrissae, or whiskers, alone. During behavior, the facial vibrissae brush against objects and undergo deflection patterns that are influenced both by the surface features of the objects and by the animal's own motion. The extent to which behavioral variability shapes the sensory inputs to this pathway is unknown. Using high-resolution, high-speed videography of unconstrained rats running on a linear track, we measured several behavioral variables including running speed, distance to the track wall, and head angle, as well as the proximal vibrissa deflections while the distal portions of the vibrissae were in contact with periodic gratings. The measured deflections, which serve as the sensory input to this pathway, were strongly modulated both by the properties of the gratings and the trial-to-trial variations in head-motion and locomotion. Using presumed internal knowledge of locomotion and head-rotation, gratings were classified using short-duration trials (<150 ms) from high-frequency vibrissa motion, and the continuous trajectory of the animal's own motion through the track was decoded from the low frequency content. Together, these results suggest that rats have simultaneous access to low- and high-frequency information about their environment, which has been shown to be parsed into different processing streams that are likely important for accurate object localization and texture coding. PMID:20164407
Signs of essential blepharospasm: a motion-picture analysis.
Coles, W H
1977-06-01
Motion pictures of 15 patients with essential blepharospasm were studied. Previously unrecognized signs indicated multiple cranial nerve involvement. These signs include impersistence of gaze, lid retraction, tongue thrust, head tilts, head jerks, vertical gaze spasms, and asymmetry. The sugns were also observed in a patient with bilateral blepharospasm who had a history of Bell's palsy suggesting facial nerve injury as a possible factor in blepharospasm. The presence of these signs can be explained by known neural pathways, but the site, or sites, of the lesion remains obscure. These signs may be important in assessing severity and in treatment evaluation.
NASA Technical Reports Server (NTRS)
Homick, J. L.; Reschke, M. F.; Vanderploeg, J. M.
1984-01-01
Better methods for the prediction, prevention, and treatment of the space adaptation syndome (SAS) were developed. A systematic, long range program of operationally oriented data collection on all individuals flying space shuttle missions was initiated. Preflight activities include the use of a motion experience questionnaire, laboratory tests of susceptibility to motion sickness induced by Coriolis stimuli and determinations of antimotion sickness drug efficacy and side effects. During flight, each crewmember is required to provide a daily report of symptom status, use of medications, and other vestibular related sensations. Additional data are obtained postflight. During the first nine shuttle missions, the reported incidence of SAS has been48%. Self-induced head motions and unusual visual orientation attitudes appear to be the principal triggering stimuli. Antimotion sickness medication, was of limited therapeutic value. Complete recovery from symptoms occurred by mission day three or four. Also of relevance is the lack of a statistically significant correlation between the ground based Coriolis test and SAS. The episodes of SAS have resulted in no impact to shuttle mission objectives and, no significant impact to mission timelines.
Global Neuromagnetic Cortical Fields Have Non-Zero Velocity
Alexander, David M.; Nikolaev, Andrey R.; Jurica, Peter; Zvyagintsev, Mikhail; Mathiak, Klaus; van Leeuwen, Cees
2016-01-01
Globally coherent patterns of phase can be obscured by analysis techniques that aggregate brain activity measures across-trials, whether prior to source localization or for estimating inter-areal coherence. We analyzed, at single-trial level, whole head MEG recorded during an observer-triggered apparent motion task. Episodes of globally coherent activity occurred in the delta, theta, alpha and beta bands of the signal in the form of large-scale waves, which propagated with a variety of velocities. Their mean speed at each frequency band was proportional to temporal frequency, giving a range of 0.06 to 4.0 m/s, from delta to beta. The wave peaks moved over the entire measurement array, during both ongoing activity and task-relevant intervals; direction of motion was more predictable during the latter. A large proportion of the cortical signal, measurable at the scalp, exists as large-scale coherent motion. We argue that the distribution of observable phase velocities in MEG is dominated by spatial filtering considerations in combination with group velocity of cortical activity. Traveling waves may index processes involved in global coordination of cortical activity. PMID:26953886
Emergence of postural patterns as a function of vision and translation frequency
NASA Technical Reports Server (NTRS)
Buchanan, J. J.; Horak, F. B.; Peterson, B. W. (Principal Investigator)
1999-01-01
Emergence of postural patterns as a function of vision and translation frequency. We examined the frequency characteristics of human postural coordination and the role of visual information in this coordination. Eight healthy adults maintained balance in stance during sinusoidal support surface translations (12 cm peak to peak) in the anterior-posterior direction at six different frequencies. Changes in kinematic and dynamic measures revealed that both sensory and biomechanical constraints limit postural coordination patterns as a function of translation frequency. At slow frequencies (0.1 and 0.25 Hz), subjects ride the platform (with the eyes open or closed). For fast frequencies (1.0 and 1.25 Hz) with the eyes open, subjects fix their head and upper trunk in space. With the eyes closed, large-amplitude, slow-sway motion of the head and trunk occurred for fast frequencies above 0.5 Hz. Visual information stabilized posture by reducing the variability of the head's position in space and the position of the center of mass (CoM) within the support surface defined by the feet for all but the slowest translation frequencies. When subjects rode the platform, there was little oscillatory joint motion, with muscle activity limited mostly to the ankles. To support the head fixed in space and slow-sway postural patterns, subjects produced stable interjoint hip and ankle joint coordination patterns. This increase in joint motion of the lower body dissipated the energy input by fast translation frequencies and facilitated the control of upper body motion. CoM amplitude decreased with increasing translation frequency, whereas the center of pressure amplitude increased with increasing translation frequency. Our results suggest that visual information was important to maintaining a fixed position of the head and trunk in space, whereas proprioceptive information was sufficient to produce stable coordinative patterns between the support surface and legs. The CNS organizes postural patterns in this balance task as a function of available sensory information, biomechanical constraints, and translation frequency.
Chang, Minsu; Kim, Yeongmin; Lee, Yoseph; Jeon, Doyoung
2017-07-01
This paper proposes a method of detecting the postural stability of a person wearing the lower limb exoskeletal robot with the HAT(Head-Arm-Trunk) model. Previous studies have shown that the human posture is stable when the CoM(Center of Mass) of the human body is placed on the BoS(Base of Support). In the case of the lower limb exoskeletal robot, the motion data, which are used for the CoM estimation, are acquired by sensors in the robot. The upper body, however, does not have sensors in each segment so that it may cause the error of the CoM estimation. In this paper, the HAT(Head-Arm-Trunk) model which combines head, arms, and torso into a single segment is considered because the motion of head and arms are unknown due to the lack of sensors. To verify the feasibility of HAT model, the reflecting markers are attached to each segment of the whole human body and the exact motion data are acquired by the VICON to compare the COM of the full body model and HAT model. The difference between the CoM with full body and that with HAT model is within 20mm for the various motions of head and arms. Based on the HAT model, the XCoM(Extrapolated Center of Mass) which includes the velocity of the CoM is used for prediction of the postural stability. The experiment of making unstable posture shows that the XCoM of the whole body based on the HAT model is feasible to detect the instance of postural instability earlier than the CoM by 20-250 msec. This result may be used for the lower limb exoskeletal robot to prepare for any action to prevent the falling down.
Scaled Jump in Gravity-Reduced Virtual Environments.
Kim, MyoungGon; Cho, Sunglk; Tran, Tanh Quang; Kim, Seong-Pil; Kwon, Ohung; Han, JungHyun
2017-04-01
The reduced gravity experienced in lunar or Martian surfaces can be simulated on the earth using a cable-driven system, where the cable lifts a person to reduce his or her weight. This paper presents a novel cable-driven system designed for the purpose. It is integrated with a head-mounted display and a motion capture system. Focusing on jump motion within the system, this paper proposes to scale the jump and reports the experiments made for quantifying the extent to which a jump can be scaled without the discrepancy between physical and virtual jumps being noticed by the user. With the tolerable range of scaling computed from these experiments, an application named retargeted jump is developed, where a user can jump up onto virtual objects while physically jumping in the real-world flat floor. The core techniques presented in this paper can be extended to develop extreme-sport simulators such as parasailing and skydiving.
Heo, Youn Moo; Kim, Sang Bum; Yi, Jin Woong; Kim, Tae Gyun; Lim, Byoung Gu
2016-02-01
As intramedullary (IM) fixation is one of the fixation methods used in neck fractures of the fifth metacarpal, an early motion of injured finger can be allowed. The purpose of this study is to evaluate whether immediate active motion affects the stability of antegrade IM fixation in surgical treatment of neck fractures of the fifth metacarpal bone and to assess related factors. Thirty one patients treated by closed reduction and antegrade IM fixation were consecutively enrolled. All patients started active motion of the little finger since 7 postoperative days and only daily activities including writing, typing or washing were allowed until the union of fracture. All fractures were healed within four to eight weeks. The changes of angulation, fifth metacarpal length and tip to head distance of K-wire were compared between immediate postoperative radiographs and radiographs at eight weeks. In addition, the effects by age, gender, initial angulation and comminution of the metacarpal neck were assessed. The average change of angulation was 0.12°, 5th metacarpal length was 1.49mm and tip to head distance of K-wire was 1.31mm. There was no significant difference in the change of angulation (p = 0.137). But, there were significant differences in the change of 5th metacarpal length and tip to head distance of K-wire ([Formula: see text]). The change of angulation was related to a comminution of the metacarpal neck and that of 5th metacarpal length was related to age and sex. The change of 5th metacarpal length and tip to head distance of K-wire can occur by an early mobilization in the antegrade IM fixation for neck fractures of the fifth metacarpal. However, we thought that an early active motion after surgery is important to increase the patients' satisfaction, even though careful selection of candidates is necessary.
Shiroguchi, Katsuyuki; Chin, Harvey F; Hannemann, Diane E; Muneyuki, Eiro; De La Cruz, Enrique M; Kinosita, Kazuhiko
2011-04-01
Myosins are ATP-driven linear molecular motors that work as cellular force generators, transporters, and force sensors. These functions are driven by large-scale nucleotide-dependent conformational changes, termed "strokes"; the "power stroke" is the force-generating swinging of the myosin light chain-binding "neck" domain relative to the motor domain "head" while bound to actin; the "recovery stroke" is the necessary initial motion that primes, or "cocks," myosin while detached from actin. Myosin Va is a processive dimer that steps unidirectionally along actin following a "hand over hand" mechanism in which the trailing head detaches and steps forward ∼72 nm. Despite large rotational Brownian motion of the detached head about a free joint adjoining the two necks, unidirectional stepping is achieved, in part by the power stroke of the attached head that moves the joint forward. However, the power stroke alone cannot fully account for preferential forward site binding since the orientation and angle stability of the detached head, which is determined by the properties of the recovery stroke, dictate actin binding site accessibility. Here, we directly observe the recovery stroke dynamics and fluctuations of myosin Va using a novel, transient caged ATP-controlling system that maintains constant ATP levels through stepwise UV-pulse sequences of varying intensity. We immobilized the neck of monomeric myosin Va on a surface and observed real time motions of bead(s) attached site-specifically to the head. ATP induces a transient swing of the neck to the post-recovery stroke conformation, where it remains for ∼40 s, until ATP hydrolysis products are released. Angle distributions indicate that the post-recovery stroke conformation is stabilized by ≥ 5 k(B)T of energy. The high kinetic and energetic stability of the post-recovery stroke conformation favors preferential binding of the detached head to a forward site 72 nm away. Thus, the recovery stroke contributes to unidirectional stepping of myosin Va.
Double-Row Capsulolabral Repair Increases Load to Failure and Decreases Excessive Motion.
McDonald, Lucas S; Thompson, Matthew; Altchek, David W; McGarry, Michelle H; Lee, Thay Q; Rocchi, Vanna J; Dines, Joshua S
2016-11-01
Using a cadaver shoulder instability model and load-testing device, we compared biomechanical characteristics of double-row and single-row capsulolabral repairs. We hypothesized a greater reduction in glenohumeral motion and translation and a higher load to failure in a mattress double-row capsulolabral repair than in a single-row repair. In 6 matched pairs of cadaveric shoulders, a capsulolabral injury was created. One shoulder was repaired with a single-row technique, and the other with a double-row mattress technique. Rotational range of motion, anterior-inferior translation, and humeral head kinematics were measured. Load-to-failure testing measured stiffness, yield load, deformation at yield load, energy absorbed at yield load, load to failure, deformation at ultimate load, and energy absorbed at ultimate load. Double-row repair significantly decreased external rotation and total range of motion compared with single-row repair. Both repairs decreased anterior-inferior translation compared with the capsulolabral-injured condition, however, no differences existed between repair types. Yield load in the single-row group was 171.3 ± 110.1 N, and in the double-row group it was 216.1 ± 83.1 N (P = .02). Ultimate load to failure in the single-row group was 224.5 ± 121.0 N, and in the double-row group it was 373.9 ± 172.0 N (P = .05). Energy absorbed at ultimate load in the single-row group was 1,745.4 ± 1,462.9 N-mm, and in the double-row group it was 4,649.8 ± 1,930.8 N-mm (P = .02). In cases of capsulolabral disruption, double-row repair techniques may result in decreased shoulder rotational range of motion and improved load-to-failure characteristics. In cases of capsulolabral disruption, repair techniques with double-row mattress repair may provide more secure fixation. Double-row capsulolabral repair decreases shoulder motion and increases load to failure, yield load, and energy absorbed at yield load more than single-row repair. Published by Elsevier Inc.
Avascular Necrosis of the Metacarpal Head: A Review of 4 Cases.
Aldekhayel, Salah; Ghanad, Erfan; Mudgal, Chaitanya S
2018-04-03
To report on 4 cases of avascular necrosis of the metacarpal head. We retrospectively reviewed 4 patients who received a diagnosis of avascular necrosis of the metacarpal head and were treated from 2000 to 2016. All patients were males with involvement of the dominant hand. Three patients had a history of trauma and/or fractures in another finger and one had a history of fracture in the same finger. The diagnosis was confirmed on regular x-rays and magnetic resonance imaging. Nonsurgical management was offered to all patients (rest, placement of an orthosis, and nonsteroidal anti-inflammatory drugs) for 3 to 6 months. Two patients responded well to nonsurgical management and improved in their symptoms. One patient refused surgical intervention and continued to have persistent pain. The other patient was treated with curettage and bone graft and had total resolution of pain symptoms with full active range of motion. A high index of suspicion is required to diagnose and treat avascular necrosis of the metacarpal head correctly. Treatment options are numerous and require further studies to investigate their effectiveness in the treatment of this rare disease. Therapeutic V. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Natural motion of the optic nerve head revealed by high speed phase-sensitive OCT
NASA Astrophysics Data System (ADS)
OHara, Keith; Schmoll, Tilman; Vass, Clemens; Leitgeb, Rainer A.
2013-03-01
We use phase-sensitive optical coherence tomography (OCT) to measure the deformation of the optic nerve head during the pulse cycle, motivated by the possibility that these deformations might be indicative of the progression of glaucoma. A spectral-domain OCT system acquired 100k A-scans per second, with measurements from a pulse-oximeter recorded simultaneously, correlating OCT data to the subject's pulse. Data acquisition lasted for 2 seconds, to cover at least two pulse cycles. A frame-rate of 200-400 B-scans per second results in a sufficient degree of correlated speckle between successive frames that the phase-differences between fames can be extracted. Bulk motion of the entire eye changes the phase by several full cycles between frames, but this does not severely hinder extracting the smaller phase-changes due to differential motion within a frame. The central cup moves about 5 μm/s relative to the retinal-pigment-epithelium edge, with tissue adjacent to blood vessels showing larger motion.
NASA Astrophysics Data System (ADS)
Rotenberg, David J.
Artifacts caused by head motion are a substantial source of error in fMRI that limits its use in neuroscience research and clinical settings. Real-time scan-plane correction by optical tracking has been shown to correct slice misalignment and non-linear spin-history artifacts, however residual artifacts due to dynamic magnetic field non-uniformity may remain in the data. A recently developed correction technique, PLACE, can correct for absolute geometric distortion using the complex image data from two EPI images, with slightly shifted k-space trajectories. We present a correction approach that integrates PLACE into a real-time scan-plane update system by optical tracking, applied to a tissue-equivalent phantom undergoing complex motion and an fMRI finger tapping experiment with overt head motion to induce dynamic field non-uniformity. Experiments suggest that including volume by volume geometric distortion correction by PLACE can suppress dynamic geometric distortion artifacts in a phantom and in vivo and provide more robust activation maps.
Use of promethazine to hasten adaptation to provocative motion
NASA Technical Reports Server (NTRS)
Lackner, J. R.; Graybiel, A.
1994-01-01
In an earlier study, the authors found that severely motion sick individuals could be greatly relieved of their symptoms by intramuscular injections of promethazine (50 mg) or scopolamine (.5 mg). Comparable 50-mg injections of promethazine also have been found effective in alleviating symptoms of space motion sickness. The concern has risen, however, that such drugs may delay or retard the acquisition of adaptation to stressful environments. In the current study, we controlled arousal using a mental arithmetic task and precisely equated the exposure history (number of head movements during rotation) of a placebo, control group and an experimental group who had received promethazine. No differences in total adaptation or in rates of adaptation were present between the two groups. Another experimental group also received promethazine and was allowed to make as many head movements as they could, before reaching nausea, up to 800. This group showed a greater level of adaptation than the placebo group. These results suggest a strategy for dealing with space motion sickness that is described.
77 FR 46762 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-06
... children involved. Respondents: Head Start and Early Head Start program grants recipients. Annual Burden... DEPARTMENT OF HEALTH AND HUMAN SERVICES Administration for Children and Families Submission for... requirement that each child be seated in a child restraint system while the vehicle is in motion, and the...
NASA Technical Reports Server (NTRS)
Solomon, D.; Cohen, B.
1992-01-01
1. A rhesus and cynomolgus monkey were trained to run around the perimeter of a circular platform in light. We call this "circular locomotion" because forward motion had an angular component. Head and body velocity in space were recorded with angular rate sensors and eye movements with electrooculography (EOG). From these measurements we derived signals related to the angular velocity of the eyes in the head (Eh), of the head on the body (Hb), of gaze on the body (Gb), of the body in space (Bs), of gaze in space (Gs), and of the gain of gaze (Gb/Bs). 2. The monkeys had continuous compensatory nystagmus of the head and eyes while running, which stabilized Gs during the slow phases. The eyes established and maintained compensatory gaze velocities at the beginning and end of the slow phases. The head contributed to gaze velocity during the middle of the slow phases. Slow phase Gb was as high as 250 degrees/s, and targets were fixed for gaze angles as large as 90-140 degrees. 3. Properties of the visual surround affected both the gain and strategy of gaze compensation in the one monkey tested. Gains of Eh ranged from 0.3 to 1.1 during compensatory gaze nystagmus. Gains of Hb varied around 0.3 (0.2-0.7), building to a maximum as Eh dropped while running past sectors of interest. Consistent with predictions, gaze gains varied from below to above unity, when translational and angular body movements with regard to the target were in opposite or the same directions, respectively. 4. Gaze moved in saccadic shifts in the direction of running during quick phases. Most head quick phases were small, and at times the head only paused during an eye quick phase. Eye quick phases were larger, ranging up to 60 degrees. This is larger than quick phases during passive rotation or saccades made with the head fixed. 5. These data indicate that head and eye nystagmus are natural phenomena that support gaze compensation during locomotion. Despite differential utilization of the head and eyes in various conditions, Gb compensated for Bs. There are various frames of reference in which an estimate of angular velocity that drives the head and eyes could be based. We infer that body in space velocity (Bs) is likely to be represented centrally to provide this signal.
Modeling heading and path perception from optic flow in the case of independently moving objects
Raudies, Florian; Neumann, Heiko
2013-01-01
Humans are usually accurate when estimating heading or path from optic flow, even in the presence of independently moving objects (IMOs) in an otherwise rigid scene. To invoke significant biases in perceived heading, IMOs have to be large and obscure the focus of expansion (FOE) in the image plane, which is the point of approach. For the estimation of path during curvilinear self-motion no significant biases were found in the presence of IMOs. What makes humans robust in their estimation of heading or path using optic flow? We derive analytical models of optic flow for linear and curvilinear self-motion using geometric scene models. Heading biases of a linear least squares method, which builds upon these analytical models, are large, larger than those reported for humans. This motivated us to study segmentation cues that are available from optic flow. We derive models of accretion/deletion, expansion/contraction, acceleration/deceleration, local spatial curvature, and local temporal curvature, to be used as cues to segment an IMO from the background. Integrating these segmentation cues into our method of estimating heading or path now explains human psychophysical data and extends, as well as unifies, previous investigations. Our analysis suggests that various cues available from optic flow help to segment IMOs and, thus, make humans' heading and path perception robust in the presence of such IMOs. PMID:23554589
Optoelectronic associative recall using motionless-head parallel readout optical disk
NASA Astrophysics Data System (ADS)
Marchand, P. J.; Krishnamoorthy, A. V.; Ambs, P.; Esener, S. C.
1990-12-01
High data rates, low retrieval times, and simple implementation are presently shown to be obtainable by means of a motionless-head 2D parallel-readout system for optical disks. Since the optical disk obviates mechanical head motions for access, focusing, and tracking, addressing is performed exclusively through the disk's rotation. Attention is given to a high-performance associative memory system configuration which employs a parallel readout disk.
Holly, Jan E.; Masood, M. Arjumand; Bhandari, Chiran S.
2017-01-01
Head movements during sustained rotation can cause angular cross-coupling which leads to tumbling illusions. Even though angular vectors predict equal magnitude illusions for head movements in opposite directions, the magnitudes of the illusions are often surprisingly asymmetric, such as during leftward versus rightward yaw while horizontal in a centrifuge. This paper presents a comprehensive investigation of the angular-linear stimulus combinations from eight different published papers in which asymmetries were found. Interactions between all angular and linear vectors, including gravity, are taken into account to model the three-dimensional consequences of the stimuli. Three main results followed. First, for every pair of head yaw movements, an asymmetry was found in the stimulus itself when considered in a fully three-dimensional manner, and the direction of the asymmetry matched the subjectively reported magnitude asymmetry. Second, for pitch and roll head movements for which motion sickness was measured, the stimulus was found symmetric in every case except one, and motion sickness generally aligned with other factors such as the existence of a head rest. Third, three-dimensional modeling predicted subjective inconsistency in the direction of perceived rotation when linear and angular components were oppositely-directed, and predicted surplus illusory rotation in the direction of head movement. PMID:27814310
Methodology for functional MRI of simulated driving.
Kan, Karen; Schweizer, Tom A; Tam, Fred; Graham, Simon J
2013-01-01
The developed world faces major socioeconomic and medical challenges associated with motor vehicle accidents caused by risky driving. Functional magnetic resonance imaging (fMRI) of individuals using virtual reality driving simulators may provide an important research tool to assess driving safety, based on brain activity and behavior. A fMRI-compatible driving simulator was developed and evaluated in the context of straight driving, turning, and stopping in 16 young healthy adults. Robust maps of brain activity were obtained, including activation of the primary motor cortex, cerebellum, visual cortex, and parietal lobe, with limited head motion (<1.5 mm deviation from mean head position in the superior∕inferior direction in all subjects) and only minor correlations between head motion, steering, or braking behavior. These results are consistent with previous literature and suggest that with care, fMRI of simulated driving is a feasible undertaking.
Motion correction in MRI of the brain
Godenschweger, F; Kägebein, U; Stucht, D; Yarach, U; Sciarra, A; Yakupov, R; Lüsebrink, F; Schulze, P; Speck, O
2016-01-01
Subject motion in MRI is a relevant problem in the daily clinical routine as well as in scientific studies. Since the beginning of clinical use of MRI, many research groups have developed methods to suppress or correct motion artefacts. This review focuses on rigid body motion correction of head and brain MRI and its application in diagnosis and research. It explains the sources and types of motion and related artefacts, classifies and describes existing techniques for motion detection, compensation and correction and lists established and experimental approaches. Retrospective motion correction modifies the MR image data during the reconstruction, while prospective motion correction performs an adaptive update of the data acquisition. Differences, benefits and drawbacks of different motion correction methods are discussed. PMID:26864183
Motion correction in MRI of the brain
NASA Astrophysics Data System (ADS)
Godenschweger, F.; Kägebein, U.; Stucht, D.; Yarach, U.; Sciarra, A.; Yakupov, R.; Lüsebrink, F.; Schulze, P.; Speck, O.
2016-03-01
Subject motion in MRI is a relevant problem in the daily clinical routine as well as in scientific studies. Since the beginning of clinical use of MRI, many research groups have developed methods to suppress or correct motion artefacts. This review focuses on rigid body motion correction of head and brain MRI and its application in diagnosis and research. It explains the sources and types of motion and related artefacts, classifies and describes existing techniques for motion detection, compensation and correction and lists established and experimental approaches. Retrospective motion correction modifies the MR image data during the reconstruction, while prospective motion correction performs an adaptive update of the data acquisition. Differences, benefits and drawbacks of different motion correction methods are discussed.
New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.
van Gastel, Mark; Stuijk, Sander; de Haan, Gerard
2016-12-07
Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO 2 ) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO 2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted by motion-induced variations. We introduce a new principle that allows accurate remote measurements even during significant subject motion. We demonstrate the main advantage of the principle, i.e. that the optimal signature remains the same even when the SNR of the PPG signal drops significantly due to motion or limited measurement area. The evaluation uses recordings with breath-holding events, which induce hypoxemia in healthy moving subjects. The events lead to clinically relevant SpO 2 levels in the range 80-100%. The new principle is shown to greatly outperform current remote ratio-of-ratios based methods. The mean-absolute SpO 2 -error (MAE) is about 2 percentage-points during head movements, where the benchmark method shows a MAE of 24 percentage-points. Consequently, we claim ours to be the first method to reliably measure SpO 2 remotely during significant subject motion.
Biased Brownian motion mechanism for processivity and directionality of single-headed myosin-VI.
Iwaki, Mitsuhiro; Iwane, Atsuko Hikikoshi; Ikebe, Mitsuo; Yanagida, Toshio
2008-01-01
Conventional form to function as a vesicle transporter is not a 'single molecule' but a coordinated 'two molecules'. The coordinated two molecules make it complicated to reveal its mechanism. To overcome the difficulty, we adopted a single-headed myosin-VI as a model protein. Myosin-VI is an intracellular vesicle and organelle transporter that moves along actin filaments in a direction opposite to most other known myosin classes. The myosin-VI was expected to form a dimer to move processively along actin filaments with a hand-over-hand mechanism like other myosin organelle transporters. However, wild-type myosin-VI was demonstrated to be monomer and single-headed, casting doubt on its processivity. Using single molecule techniques, we show that green fluorescent protein (GFP)-fused single-headed myosin-VI does not move processively. However, when coupled to a 200 nm polystyrene bead (comparable to an intracellular vesicle in size) at a ratio of one head per bead, single-headed myosin-VI moves processively with large (40 nm) steps. Furthermore, we found that a single-headed myosin-VI-bead complex moved more processively in a high-viscous solution (40-fold higher than water) similar to cellular environment. Because diffusion of the bead is 60-fold slower than myosin-VI heads alone in water, we propose a model in which the bead acts as a diffusional anchor for the myosin-VI, enhancing the head's rebinding following detachment and supporting processive movement of the bead-monomer complex. This investigation will help us understand how molecular motors utilize Brownian motion in cells.
Motion parallax in immersive cylindrical display systems
NASA Astrophysics Data System (ADS)
Filliard, N.; Reymond, G.; Kemeny, A.; Berthoz, A.
2012-03-01
Motion parallax is a crucial visual cue produced by translations of the observer for the perception of depth and selfmotion. Therefore, tracking the observer viewpoint has become inevitable in immersive virtual (VR) reality systems (cylindrical screens, CAVE, head mounted displays) used e.g. in automotive industry (style reviews, architecture design, ergonomics studies) or in scientific studies of visual perception. The perception of a stable and rigid world requires that this visual cue be coherent with other extra-retinal (e.g. vestibular, kinesthetic) cues signaling ego-motion. Although world stability is never questioned in real world, rendering head coupled viewpoint in VR can lead to the perception of an illusory perception of unstable environments, unless a non-unity scale factor is applied on recorded head movements. Besides, cylindrical screens are usually used with static observers due to image distortions when rendering image for viewpoints different from a sweet spot. We developed a technique to compensate in real-time these non-linear visual distortions, in an industrial VR setup, based on a cylindrical screen projection system. Additionally, to evaluate the amount of discrepancies tolerated without perceptual distortions between visual and extraretinal cues, a "motion parallax gain" between the velocity of the observer's head and that of the virtual camera was introduced in this system. The influence of this artificial gain was measured on the gait stability of free-standing participants. Results indicate that, below unity, gains significantly alter postural control. Conversely, the influence of higher gains remains limited, suggesting a certain tolerance of observers to these conditions. Parallax gain amplification is therefore proposed as a possible solution to provide a wider exploration of space to users of immersive virtual reality systems.
NASA Technical Reports Server (NTRS)
Correia, Manning J.; Luke, Brian L.; McGrath, Braden J.; Clark, John B.; Rupert, Angus H.
1996-01-01
While considerable attention has been given to visual-vestibular interaction (VVI) during angular motion of the head as might occur during an aircraft spin, much less attention has been given to VVI during linear motion of the head. Such interaction might occur, for example, while viewing a stationary or moving display during vertical take-off and landing operations Research into linear VVI, particularly during prolonged periods of linear acceleration, has been hampered by the unavailability of a programmable translator capable of large excursions We collaborated with Otis Elevator Co. and used their research tower and elevator, whose motion could be digitally programmed, to vertically translate human subjects over a distance of 92.3 meters with a peak linear acceleration of 2 meters/sec(exp 2) During pulsatile or sinusoidal translation, the subjects viewed moving stripes (optokinetic stimulus) or a fixed point source (light emitting diode, led, display), respectively and it was generally found that. The direction of linear acceleration relative to the cardinal head axes and the direction of the slow component of optokinetic nystagmus (OKN) determined the extent of VVI during concomitant stripe motion and linear acceleration. Acceleration along the z head axis (A(sub z)) produced the largest VVI, particularly when the slow component of OKN was in the same direction as eye movements produced by the linear acceleration and Eye movements produced by linear acceleration are suppressed by viewing a fixed target at frequencies below 10 Hz But, above this frequency the suppression produced by VVI is removed. Finally, as demonstrated in non-human primates, vergence of the eyes appears to modulate the vertical eye movement response to linear acceleration in humans.
Kinematic response of the spine during simulated aircraft ejections.
Damon, Andrew M; Lessley, David J; Salzar, Robert S; Bass, Cameron R; Shen, Francis H; Paskoff, Glenn R; Shender, Barry S
2010-05-01
Military aviators are susceptible to spinal injuries during high-speed ejection scenarios. These injuries commonly arise as a result of strains induced by extreme flexion or compression of the spinal column. This study characterizes the vertebral motion of two postmortem human surrogates (PMHS) during a simulated catapult phase of ejection on a horizontal decelerator sled. During testing, the PMHS were restrained supinely to a mock ejection seat and subjected to a horizontal deceleration profile directed along the local z-axis. Two midsized males (175.3 cm, 77.1 kg; 185.4 cm, 72.6 kg) were tested. High-rate motion capture equipment was used to measure the three-dimensional displacement of the head, vertebrae, and pelvis during the ejection event. The two PMHS showed generally similar kinematic motion. Head injury criterion (HIC) results were well below injury threshold levels for both specimens. The specimens both showed compression of the spine, with a reduction in length of 23.9 mm and 45.7 mm. Post-test autopsies revealed fractures in the C5, T1, and L1 vertebrae. This paper provides an analysis of spinal motion during an aircraft ejection.The injuries observed in the test subjects were consistent with those seen in epidemiological studies. Future studies should examine the effects of gender, muscle tensing, out-of-position (of head from neutral position) occupants, and external forces (e.g., windblast) on spinal kinematics during aircraft ejection.
SU-E-J-163: A Biomechanical Lung Model for Respiratory Motion Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, X; Belcher, AH; Grelewicz, Z
2015-06-15
Purpose: This work presents a biomechanical model to investigate the complex respiratory motion for the lung tumor tracking in radiosurgery by computer simulation. Methods: The models include networked massspring-dampers to describe the tumor motion, different types of surrogate signals, and the force generated by the diaphragm. Each mass-springdamper has the same mechanical structure and each model can have different numbers of mass-spring-dampers. Both linear and nonlinear stiffness parameters were considered, and the damping ratio was tuned in a range so that the tumor motion was over-damped (no natural tumor oscillation occurs without force from the diaphragm). The simulation was runmore » by using ODE45 (ordinary differential equations by Runge-Kutta method) in MATLAB, and all time courses of motions and inputs (force) were generated and compared. Results: The curvature of the motion time courses around their peaks was sensitive to the damping ratio. Therefore, the damping ratio can be determined based on the clinical data of a high sampling rate. The peak values of different signals and the time the peaks occurred were compared, and it was found that the diaphragm force had a time lead over the tumor motion, and the lead time (0.1–0.4 seconds) depended on the distance between the tumor and the diaphragm. Conclusion: We reported a model based analysis approach for the spatial and temporal relation between the motion of the lung tumor and the surrogate signals. Due to the phase lead of the diaphragm in comparing with the lung tumor motion, the measurement of diaphragm motion (or its electromyography signal) can be used as a beam gating signal in radiosurgery, and it can also be an additional surrogate signal for better tumor motion tracking. The research is funded by the American Cancer Society (ACS) grant. The grant name is: Frameless SRS Based on Robotic Head Motion Cancellation. The grant number is: RSG-13-313-01-CCE.« less
The cat vertebral column: stance configuration and range of motion
NASA Technical Reports Server (NTRS)
Macpherson, J. M.; Ye, Y.; Peterson, B. W. (Principal Investigator)
1998-01-01
This study examined the configuration of the vertebral column of the cat during independent stance and in various flexed positions. The range of motion in the sagittal plane is similar across most thoracic and lumbar joints, with the exception of a lesser range at the transition region from thoracic-type to lumbar-type vertebrae. The upper thoracic column exhibits most of its range in dorsiflexion and the lower thoracic and lumbar in ventroflexion. Lateral flexion is limited to less than 5 degrees at all segments. The range in torsion is almost 180 degrees and occurs primarily in the midthoracic region, T4-T11. Contrary to the depiction in most atlases, the standing cat exhibits several curvatures, including a mild dorsiflexion in the lower lumbar segments, a marked ventroflexion in the lower thoracic and upper lumbar segments, and a profound dorsiflexion in the upper thoracic (above T9) and cervical segments. The curvatures are not significantly changed by altering stance distance but are affected by head posture. During stance, the top of the scapula lies well above the spines of the thoracic vertebrae, and the glenohumeral joint is just below the bodies of vertebrae T3-T5. Using a simple static model of the vertebral column in the sagittal plane, it was estimated that the bending moment due to gravity is bimodal with a dorsiflexion moment in the lower thoracic and lumbar region and a ventroflexion moment in the upper thoracic and cervical region. Given the bending moments and the position of the scapula during stance, it is proposed that two groups of scapular muscles provide the major antigravity support for the head and anterior trunk. Levator scapulae and serratus ventralis form the lateral group, inserting on the lateral processes of cervical vertebrae and on the ribs. The major and minor rhomboids form the medial group, inserting on the spinous tips of vertebrae from C4 to T4. It is also proposed that the hypaxial muscles, psoas major, minor, and quadratus lumborum could support the lumbar trunk during stance.
Neural Integration of Information Specifying Human Structure from Form, Motion, and Depth
Jackson, Stuart; Blake, Randolph
2010-01-01
Recent computational models of biological motion perception operate on ambiguous two-dimensional representations of the body (e.g., snapshots, posture templates) and contain no explicit means for disambiguating the three-dimensional orientation of a perceived human figure. Are there neural mechanisms in the visual system that represent a moving human figure’s orientation in three dimensions? To isolate and characterize the neural mechanisms mediating perception of biological motion, we used an adaptation paradigm together with bistable point-light (PL) animations whose perceived direction of heading fluctuates over time. After exposure to a PL walker with a particular stereoscopically defined heading direction, observers experienced a consistent aftereffect: a bistable PL walker, which could be perceived in the adapted orientation or reversed in depth, was perceived predominantly reversed in depth. A phase-scrambled adaptor produced no aftereffect, yet when adapting and test walkers differed in size or appeared on opposite sides of fixation aftereffects did occur. Thus, this heading direction aftereffect cannot be explained by local, disparity-specific motion adaptation, and the properties of scale and position invariance imply higher-level origins of neural adaptation. Nor is disparity essential for producing adaptation: when suspended on top of a stereoscopically defined, rotating globe, a context-disambiguated “globetrotter” was sufficient to bias the bistable walker’s direction, as were full-body adaptors. In sum, these results imply that the neural signals supporting biomotion perception integrate information on the form, motion, and three-dimensional depth orientation of the moving human figure. Models of biomotion perception should incorporate mechanisms to disambiguate depth ambiguities in two-dimensional body representations. PMID:20089892
Will New Metal Heads Restore Mechanical Integrity of Corroded Trunnions?
Derasari, Aditya; Gold, Jonathan E; Ismaily, Sabir; Noble, Philip C; Incavo, Stephen J
2017-04-01
Metal wear and corrosion from modular junctions in total hip arthroplasty can lead to further unwanted surgery. Trunnion tribocorrosion is recognized as an important contributor to failure. This study was performed to determine if new metal heads restore mechanical integrity of the original modular junction after impaction on corroded trunnions, and assess which variables affect stability of the new interface created at revision total hip arthroplasty. Twenty-two trunnions, cobalt-chromium (CoCr) and titanium alloy (TiAIV), (CoCr, n = 12; TiAIV, n = 10) and new metal heads were used, 10 trunnions in pristine condition and 12 with corrosion damage. Test states were performed using an MTS Machine and included the following: 1, Assembly; 2, Disassembly; 3, Assembly; 4, Toggling; and 5, Disassembly. During loading, three-dimensional motion of the head-trunnion junction was measured using a custom jig. There were no statistical differences in the tested mechanical properties between corroded and pristine trunnions implanted with a new metal femoral head. Average micromotion of the head versus trunnion interface was greatest at the start of loading, stabilizing after approximately 50 loading cycles at an average of 30.6 ± 3.2 μm. Corrosion at the trunnion does not disrupt mechanical integrity of the junction when a CoCr head is replaced with a CoCr trunnion. However, increased interface motion of a new metal head on a corroded titanium trunnion requires additional study. The evaluation of ball head size on mechanical integrity of trunnions would also be a potential subject of future investigation, as increasing the ball head size at the time of revision is not uncommon in revisions today. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Dong Wook; Bae, Sunhyun; Chung, Weon Kuu; Lee, Yoonhee
2014-04-01
Cone-beam computed tomography (CBCT) images are currently used for patient positioning and adaptive dose calculation; however, the degree of CBCT uncertainty in cases of respiratory motion remains an interesting issue. This study evaluated the uncertainty of CBCT-based dose calculations for a moving target. Using a phantom, we estimated differences in the geometries and the Hounsfield units (HU) between CT and CBCT. The calculated dose distributions based on CT and CBCT images were also compared using a radiation treatment planning system, and the comparison included cases with respiratory motion. The geometrical uncertainties of the CT and the CBCT images were less than 0.15 cm. The HU differences between CT and CBCT images for standard-dose-head, high-quality-head, normal-pelvis, and low-dose-thorax modes were 31, 36, 23, and 33 HU, respectively. The gamma (3%, 0.3 cm)-dose distribution between CT and CBCT was greater than 1 in 99% of the area. The gamma-dose distribution between CT and CBCT during respiratory motion was also greater than 1 in 99% of the area. The uncertainty of the CBCT-based dose calculation was evaluated for cases with respiratory motion. In conclusion, image distortion due to motion did not significantly influence dosimetric parameters.
Assessment of neck pain and cervical mobility among female computer workers at Hail University.
Mohammad, Walaa S; Hamza, Hayat H; ElSais, Walaa M
2015-01-01
The aims of this study were to investigate the prevalence of neck pain among computer workers at Hail University, Saudi Arabia and to compare the cervical range of motion (ROM) of female computer workers suffering from neck pain to the cervical ROM of healthy female computer workers. One hundred and seventy-six female volunteers between 20 and 46 years of age were investigated. Fifty-six of these volunteers were staff members, 22 were administrators and 98 were students. The Cervical Range of Motion (CROM) instrument was used to measure the ROM of the cervical spine. A questionnaire was used to assess participants for the presence of neck pain. The data were analyzed using the Statistical Package for Social Sciences (SPSS) software, and the level of significant was set at p < .05 for all statistical tests. There was a high prevalence of neck pain (75%) among computer workers at Hail University, particularly among students. There were significant differences in cervical lateral flexion, rotation to the right side and protraction range between the pain and pain-free groups. Our results demonstrated that cervical ROM measurements, particularly cervical lateral flexion, rotation and protraction, could be useful for predicting changes in head and neck posture after long-term computer work.
Mounted Combat System Crew Shock Loading: Head and Neck Injury Potential Evaluation
2007-07-01
including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing...degrees. The raw data for this project were collected by the Motion Base Technologies Team of TARDEC and their contractors. The data were sent to the...relating the neck force and torque and head accelerations to establish injury criteria for the neck and head. Data from the Hybrid III manikin were
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... Project facilities to provide an improved low-flow release system for the City's water treatment plant. l... ``COMMENTS'', ``PROTEST'', or ``MOTION TO INTERVENE'' as applicable; (2) set forth in the heading the name of... protests must set forth their evidentiary [[Page 32624
Constructing Carbon Fiber Motion-Detection Loops for Simultaneous EEG–fMRI
Abbott, David F.; Masterton, Richard A. J.; Archer, John S.; Fleming, Steven W.; Warren, Aaron E. L.; Jackson, Graeme D.
2015-01-01
One of the most significant impediments to high-quality EEG recorded in an MRI scanner is subject motion. Availability of motion artifact sensors can substantially improve the quality of the recorded EEG. In the study of epilepsy, it can also dramatically increase the confidence that one has in discriminating true epileptiform activity from artifact. This is due both to the reduction in artifact and the ability to visually inspect the motion sensor signals when reading the EEG, revealing whether or not head motion is present. We have previously described the use of carbon fiber loops for detecting and correcting artifact in EEG acquired simultaneously with MRI. The loops, attached to the subject’s head, are electrically insulated from the scalp. They provide a simple and direct measure of specific artifact that is contaminating the EEG, including both subject motion and residual artifact arising from magnetic field gradients applied during MRI. Our previous implementation was used together with a custom-built EEG–fMRI system that differs substantially from current commercially available EEG–fMRI systems. The present technical note extends this work, describing in more detail how to construct the carbon fiber motion-detection loops, and how to interface them with a commercially available simultaneous EEG–fMRI system. We hope that the information provided may help those wishing to utilize a motion-detection/correction solution to improve the quality of EEG recorded within an MRI scanner. PMID:25601852
Reduced mandibular range of motion in Duchenne Muscular Dystrophy: predictive factors.
van Bruggen, H W; Van Den Engel-Hoek, L; Steenks, M H; Bronkhorst, E M; Creugers, N H J; de Groot, I J M; Kalaykova, S I
2015-06-01
Patients with Duchenne muscular dystrophy (DMD) experience negative effects upon feeding and oral health. We aimed to determine whether the mandibular range of motion in DMD is impaired and to explore predictive factors for the active maximum mouth opening (aMMO). 23 patients with DMD (mean age 16.7 ± 7.7 years) and 23 controls were assessed using a questionnaire about mandibular function and impairments. All participants underwent a clinical examination of the masticatory system, including measurement of mandibular range of motion and variables related to mandibular movements. In all patients, quantitative ultrasound of the digastric muscle and the geniohyoid muscle and the motor function measure (MFM) scale were performed. The patients were divided into early and late ambulatory stage (AS), early non-ambulatory stage (ENAS) and late non-ambulatory stage (LNAS). All mandibular movements were reduced in the patient group (P < 0.001) compared to the controls. Reduction in the aMMO (<40 mm) was found in 26% of the total patient group. LNAS patients had significantly smaller mandibular movements compared to AS and ENAS (P < 0.05). Multiple linear regression analysis for aMMO revealed a positive correlation with the body height and disease progression, with MFM total score as the strongest independent risk factor (R(2) = 0.71). Mandibular movements in DMD are significantly reduced and become more hampered with loss of motor function, including the sitting position, arm function, and neck and head control. We suggest that measurement of the aMMO becomes a part of routine care of patients with DMD. © 2015 John Wiley & Sons Ltd.
Palmgren, Per J; Sandström, Peter J; Lundqvist, Fredrik J; Heikkilä, Hannu
2006-02-01
The objective of this study was to examine alteration in head repositioning accuracy (HRA), range of motion, and pain intensity in patients with chronic cervical pain syndrome without a history of cervical trauma. The study was a prospective, randomized, controlled trial. Forty-one patients with chronic cervical pain were randomly assigned to either a control group or a chiropractic treatment group. All patients were clinically examined, given general information on cervical pain, and provided with training instructions based on the clinical evaluation. The treatment included sessions with high-velocity and low-amplitude manipulation, proprioceptive neuromuscular facilitation, ischemic compression of myofascial trigger points, and spinal rehabilitation exercises aiming to normalize cervical range of motion (CROM) and HRA. Subjective pain intensity, cervical kinesthetic sensibility, and CROM were recorded before and after the study period. There was no difference between the treatment patients and the control subjects at the beginning with regard to age, sex, subjective pain intensity, range of motion, and HRA. At the 5-week follow-up, the treatment patients showed significant reductions in pain and improvement of all HRA aspects measured whereas the control subjects did not show any reduction in pain and improvement in only one HRA aspect. No significant difference was detected in CROM. The results of this study suggest that chiropractic care can be effective in influencing the complex process of proprioceptive sensibility and pain of cervical origin. Short, specific chiropractic treatment programs with proper patient information may alter the course of chronic cervical pain.
NASA Technical Reports Server (NTRS)
Guedry, F. E.; Paloski, W. F. (Principal Investigator)
1996-01-01
When head motion includes a linear velocity component, eye velocity required to track an earth-fixed target depends upon: a) angular and linear head velocity, b) target distance, and c) direction of gaze relative to the motion trajectory. Recent research indicates that eye movements (LVOR), presumably otolith-mediated, partially compensate for linear velocity in small head excursions on small devices. Canal-mediated eye velocity (AVOR), otolith-mediated eye velocity (LVOR), and Ocular Torsion (OT) can be measured, one by one, on small devices. However, response dynamics that depend upon the ratio of linear to angular velocity in the motion trajectory and on subject orientation relative to the trajectory are present in a centrifuge paradigm. With this paradigm, two 3-min runs yields measures of: LVOR differentially modulated by different subject orientations in the two runs; OT dynamics in four conditions; two directions of "steady-state" OT, and two directions of AVOR. Efficient assessment of the dynamics (and of the underlying central integrative processes) may require a centrifuge radius of 1.0 meters or more. Clinical assessment of the spatial orientation system should include evaluation of central integrative processes that determine the dynamics of these responses.
Pressure-Induced Changes in the Structure and Function of the Kinesin-Microtubule Complex
Nishiyama, Masayoshi; Kimura, Yoshifumi; Nishiyama, Yoshio; Terazima, Masahide
2009-01-01
Kinesin-1 is an ATP-driven molecular motor that “walks” along a microtubule by working two heads in a “hand-over-hand” fashion. The stepping motion is well-coordinated by intermolecular interactions between the kinesin head and microtubule, and is sensitively changed by applied forces. We demonstrate that hydrostatic pressure works as an inhibitory action on kinesin motility. We developed a high-pressure microscope that enables the application of hydrostatic pressures of up to 200 MPa (2000 bar). Under high-pressure conditions, taxol-stabilized microtubules were shortened from both ends at the same speed. The sliding velocity of kinesin motors was reversibly changed by pressure, and reached half-maximal value at ∼100 MPa. The pressure-velocity relationship was very close to the force-velocity relationship of single kinesin molecules, suggesting a similar inhibitory mechanism on kinesin motility. Further analysis showed that the pressure mainly affects the stepping motion, but not the ATP binding reaction. The application of pressure is thought to enhance the structural fluctuation and/or association of water molecules with the exposed regions of the kinesin head and microtubule. These pressure-induced effects could prevent kinesin motors from completing the stepping motion. PMID:19186149
NASA Astrophysics Data System (ADS)
Bouaynaya, N.; Schonfeld, Dan
2005-03-01
Many real world applications in computer and multimedia such as augmented reality and environmental imaging require an elastic accurate contour around a tracked object. In the first part of the paper we introduce a novel tracking algorithm that combines a motion estimation technique with the Bayesian Importance Sampling framework. We use Adaptive Block Matching (ABM) as the motion estimation technique. We construct the proposal density from the estimated motion vector. The resulting algorithm requires a small number of particles for efficient tracking. The tracking is adaptive to different categories of motion even with a poor a priori knowledge of the system dynamics. Particulary off-line learning is not needed. A parametric representation of the object is used for tracking purposes. In the second part of the paper, we refine the tracking output from a parametric sample to an elastic contour around the object. We use a 1D active contour model based on a dynamic programming scheme to refine the output of the tracker. To improve the convergence of the active contour, we perform the optimization over a set of randomly perturbed initial conditions. Our experiments are applied to head tracking. We report promising tracking results in complex environments.
A unified probabilistic framework for spontaneous facial action modeling and understanding.
Tong, Yan; Chen, Jixu; Ji, Qiang
2010-02-01
Facial expression is a natural and powerful means of human communication. Recognizing spontaneous facial actions, however, is very challenging due to subtle facial deformation, frequent head movements, and ambiguous and uncertain facial motion measurements. Because of these challenges, current research in facial expression recognition is limited to posed expressions and often in frontal view. A spontaneous facial expression is characterized by rigid head movements and nonrigid facial muscular movements. More importantly, it is the coherent and consistent spatiotemporal interactions among rigid and nonrigid facial motions that produce a meaningful facial expression. Recognizing this fact, we introduce a unified probabilistic facial action model based on the Dynamic Bayesian network (DBN) to simultaneously and coherently represent rigid and nonrigid facial motions, their spatiotemporal dependencies, and their image measurements. Advanced machine learning methods are introduced to learn the model based on both training data and subjective prior knowledge. Given the model and the measurements of facial motions, facial action recognition is accomplished through probabilistic inference by systematically integrating visual measurements with the facial action model. Experiments show that compared to the state-of-the-art techniques, the proposed system yields significant improvements in recognizing both rigid and nonrigid facial motions, especially for spontaneous facial expressions.
Shirzadi, Zahra; Crane, David E; Robertson, Andrew D; Maralani, Pejman J; Aviv, Richard I; Chappell, Michael A; Goldstein, Benjamin I; Black, Sandra E; MacIntosh, Bradley J
2015-11-01
To evaluate the impact of rejecting intermediate cerebral blood flow (CBF) images that are adversely affected by head motion during an arterial spin labeling (ASL) acquisition. Eighty participants were recruited, representing a wide age range (14-90 years) and heterogeneous cerebrovascular health conditions including bipolar disorder, chronic stroke, and moderate to severe white matter hyperintensities of presumed vascular origin. Pseudocontinuous ASL and T1 -weigthed anatomical images were acquired on a 3T scanner. ASL intermediate CBF images were included based on their contribution to the mean estimate, with the goal to maximize CBF detectability in gray matter (GM). Simulations were conducted to evaluate the performance of the proposed optimization procedure relative to other ASL postprocessing approaches. Clinical CBF images were also assessed visually by two experienced neuroradiologists. Optimized CBF images (CBFopt ) had significantly greater agreement with a synthetic ground truth CBF image and greater CBF detectability relative to the other ASL analysis methods (P < 0.05). Moreover, empirical CBFopt images showed a significantly improved signal-to-noise ratio relative to CBF images obtained from other postprocessing approaches (mean: 12.6%; range 1% to 56%; P < 0.001), and this improvement was age-dependent (P = 0.03). Differences between CBF images from different analysis procedures were not perceptible by visual inspection, while there was a moderate agreement between the ratings (κ = 0.44, P < 0.001). This study developed an automated head motion threshold-free procedure to improve the detection of CBF in GM. The improvement in CBF image quality was larger when considering older participants. © 2015 Wiley Periodicals, Inc.
Kim, Kyoungyoun; Sureshkumar, Radhakrishna
2013-06-01
To study the influence of dynamic interactions between turbulent vortical structures and polymer stress on turbulent friction drag reduction, a series of simulations of channel flow is performed. We obtain self-consistent evolution of an initial eddy in the presence of polymer stresses by utilizing the finitely extensible nonlinear elastic-Peterlin (FENE-P) model. The initial eddy is extracted by the conditional averages for the second quadrant event from fully turbulent Newtonian flow, and the initial polymer conformation fields are given by the solutions of the FENE-P model equations corresponding to the mean shear flow in the Newtonian case. At a relatively low Weissenberg number We(τ) (=50), defined as the ratio of the polymer relaxation time to the wall time scale, the generation of new vortices is inhibited by polymer-induced countertorques. Thus fewer vortices are generated in the buffer layer. However, the head of the primary hairpin is unaffected by the polymer stress. At larger We(τ) values (≥100), the hairpin head becomes weaker and vortex autogeneration and Reynolds stress growth are almost entirely suppressed. The temporal evolution of the vortex strength and polymer torque magnitude reveals that polymer extension by the vortical motion results in a polymer torque that increases in magnitude with time until a maximum value is reached over a time scale comparable to the polymer relaxation time. The polymer torque retards the vortical motion and Reynolds stress production, which in turn weakens flow-induced chain extension and torque itself. An analysis of the vortex time scales reveals that with increasing We(τ), vortical motions associated with a broader range of time scales are affected by the polymer stress. This is qualitatively consistent with Lumley's time criterion for the onset of drag reduction.
Ranging Apparatus and Method Implementing Stereo Vision System
NASA Technical Reports Server (NTRS)
Li, Larry C. (Inventor); Cox, Brian J. (Inventor)
1997-01-01
A laser-directed ranging system for use in telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a left and right video camera mounted on a camera platform, and a remotely positioned operator. The position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. A laser is provided between the left and right video camera and is directed by the user to point to a target device. The images produced by the left and right video cameras are processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. The horizontal disparity between the two processed images is calculated for use in a stereometric ranging analysis from which range is determined.
Whiplash syndrome: kinematic factors influencing pain patterns.
Cusick, J F; Pintar, F A; Yoganandan, N
2001-06-01
The overall, local, and segmental kinematic responses of intact human cadaver head-neck complexes undergoing an inertia-type rear-end impact were quantified. High-speed, high-resolution digital video data of individual facet joint motions during the event were statistically evaluated. To deduce the potential for various vertebral column components to be exposed to adverse strains that could result in their participation as pain generators, and to evaluate the abnormal motions that occur during this traumatic event. The vertebral column is known to incur a nonphysiologic curvature during the application of an inertial-type rear-end impact. No previous studies, however, have quantified the local component motions (facet joint compression and sliding) that occur as a result of rear-impact loading. Intact human cadaver head-neck complexes underwent inertia-type rear-end impact with predominant moments in the sagittal plane. High-resolution digital video was used to track the motions of individual facet joints during the event. Localized angular motion changes at each vertebral segment were analyzed to quantify the abnormal curvature changes. Facet joint motions were analyzed statistically to obtain differences between anterior and posterior strains. The spine initially assumed an S-curve, with the upper spinal levels in flexion and the lower spinal levels in extension. The upper C-spine flexion occurred early in the event (approximately 60 ms) during the time the head maintained its static inertia. The lower cervical spine facet joints demonstrated statistically greater compressive motions in the dorsal aspect than in the ventral aspect, whereas the sliding anteroposterior motions were the same. The nonphysiologic kinematic responses during a whiplash impact may induce stresses in certain upper cervical neural structures or lower facet joints, resulting in possible compromise sufficient to elicit either neuropathic or nociceptive pain. These dynamic alterations of the upper level (occiput to C2) could impart potentially adverse forces to related neural structures, with subsequent development of a neuropathic pain process. The pinching of the lower facet joints may lead to potential for local tissue injury and nociceptive pain.
A neural-based remote eye gaze tracker under natural head motion.
Torricelli, Diego; Conforto, Silvia; Schmid, Maurizio; D'Alessio, Tommaso
2008-10-01
A novel approach to view-based eye gaze tracking for human computer interface (HCI) is presented. The proposed method combines different techniques to address the problems of head motion, illumination and usability in the framework of low cost applications. Feature detection and tracking algorithms have been designed to obtain an automatic setup and strengthen the robustness to light conditions. An extensive analysis of neural solutions has been performed to deal with the non-linearity associated with gaze mapping under free-head conditions. No specific hardware, such as infrared illumination or high-resolution cameras, is needed, rather a simple commercial webcam working in visible light spectrum suffices. The system is able to classify the gaze direction of the user over a 15-zone graphical interface, with a success rate of 95% and a global accuracy of around 2 degrees , comparable with the vast majority of existing remote gaze trackers.
Kumar, Davendra; Joshi, Anil; Naqvi, S M K
2010-04-01
A study was conducted to evaluate the semen production and sperm motion characteristics of ram lambs by computer-aided semen analysis technique. Eight Malpura rams were raised under intensive management system and were trained for semen collection at a weekly interval from the age of 6 months. Rams were scheduled for semen collection at a weekly interval up to 1 year of age to assess their potential for semen production and objective evaluation of semen quality. The average age of ram lambs at the time of first ejaculation was 219 days ranging from 186 to 245 days. The age of ram lambs significantly (p < 0.05) influenced sperm concentration, sperm velocities, and beat frequency of spermatozoa, which were higher in 9-12-month-old compared to 6-9-month-old ram lambs. However, the effect of age was not significant on semen volume, percent motility, percent rapid, medium or slow motile spermatozoa, percent linearity, percent straightness, amplitude of lateral head displacement, percent elongation, and area of sperm head. The body weight of ram lambs was significantly (p < 0.01) and positively correlated (r = 0.46) with age. The results indicate that Malpura ram lambs of 9-12 months of age raised under the intensive management system in a semiarid tropical environment can produce good quality of semen.
Schrader, Alex M.; Donaldson, Stephen H.; Song, Jinsuk; Cheng, Chi-Yuan; Lee, Dong Woog; Han, Songi; Israelachvili, Jacob N.
2015-01-01
Dimethyl sulfoxide (DMSO) is a common solvent and biological additive possessing well-known utility in cellular cryoprotection and lipid membrane permeabilization, but the governing mechanisms at membrane interfaces remain poorly understood. Many studies have focused on DMSO–lipid interactions and the subsequent effects on membrane-phase behavior, but explanations often rely on qualitative notions of DMSO-induced dehydration of lipid head groups. In this work, surface forces measurements between gel-phase dipalmitoylphosphatidylcholine membranes in DMSO–water mixtures quantify the hydration- and solvation-length scales with angstrom resolution as a function of DMSO concentration from 0 mol% to 20 mol%. DMSO causes a drastic decrease in the range of the steric hydration repulsion, leading to an increase in adhesion at a much-reduced intermembrane distance. Pulsed field gradient NMR of the phosphatidylcholine (PC) head group analogs, dimethyl phosphate and tetramethylammonium ions, shows that the ion hydrodynamic radius decreases with increasing DMSO concentration up to 10 mol% DMSO. The complementary measurements indicate that, at concentrations below 10 mol%, the primary effect of DMSO is to decrease the solvated volume of the PC head group and that, from 10 mol% to 20 mol%, DMSO acts to gradually collapse head groups down onto the surface and suppress their thermal motion. This work shows a connection between surface forces, head group conformation and dynamics, and surface water diffusion, with important implications for soft matter and colloidal systems. PMID:26261313
Tracking a Head-Mounted Display in a Room-Sized Environment with Head-Mounted Cameras
1990-04-01
poor resolution and a very limited working volume [Wan90]. 4 OPTOTRAK [Nor88] uses one camera with two dual-axis CCD infrared position sensors. Each...Nor88] Northern Digital. Trade literature on Optotrak - Northern Digital’s Three Dimensional Optical Motion Tracking and Analysis System. Northern Digital
Studying Upper-Limb Amputee Prosthesis Use to Inform Device Design
2015-10-01
the study. This equipment has included a modified GoPro head-mounted camera and a Vicon 13-camera optical motion capture system, which was not part...also completed for relevant members of the study team. 4. The head-mounted camera setup has been established (a modified GoPro Hero 3 with external
Influence of moving visual environment on sit-to-stand kinematics in children and adults.
Slaboda, Jill C; Barton, Joseph E; Keshner, Emily A
2009-08-01
The effect of visual field motion on the sit-to-stand kinematics of adults and children was investigated. Children (8 to12 years of age) and adults (21 to 49 years of age) were seated in a virtual environment that rotated in the pitch and roll directions. Participants stood up either (1) concurrent with onset of visual motion or (2) after an immersion period in the moving visual environment, and (3) without visual input. Angular velocities of the head with respect to the trunk, and trunk with respect to the environment, w ere calculated as was head andtrunk center of mass. Both adults and children reduced head and trunk angular velocity after immersion in the moving visual environment. Unlike adults, children demonstrated significant differences in displacement of the head center of mass during the immersion and concurrent trials when compared to trials without visual input. Results suggest a time-dependent effect of vision on sit-to-stand kinematics in adults, whereas children are influenced by the immediate presence or absence of vision.
Williams, Matthew R.; Kirsch, Robert F.
2013-01-01
We investigated the performance of three user interfaces for restoration of cursor control in individuals with tetraplegia: head orientation, EMG from face and neck muscles, and a standard computer mouse (for comparison). Subjects engaged in a 2D, center-out, Fitts’ Law style task and performance was evaluated using several measures. Overall, head orientation commanded motion resembled mouse commanded cursor motion (smooth, accurate movements to all targets), although with somewhat lower performance. EMG commanded movements exhibited a higher average speed, but other performance measures were lower, particularly for diagonal targets. Compared to head orientation, EMG as a cursor command source was less accurate, was more affected by target direction and was more prone to overshoot the target. In particular, EMG commands for diagonal targets were more sequential, moving first in one direction and then the other rather than moving simultaneous in the two directions. While the relative performance of each user interface differs, each has specific advantages depending on the application. PMID:18990652
Spatial Transformation of the Vestibulo-Ocular Reflex during Spaceflight
NASA Technical Reports Server (NTRS)
Clement, Gilles; Wood, Scott J.; Reschke, Millard F.
1996-01-01
It was hypothesized that the absence of the gravitational reference cues may be responsible for adaptive changes in the vestibulo-ocular reflex (VOR). These changes result in the alteration of the direction of the compensatory slow phase (SP) eye movements in microgravity. In order to test this hypothesis, the direction of the VOR SP relative to head motion was investigated in three astronauts during and after an eight-day orbital flight by passive sinusoidal pitch or yaw angular motion at two frequencies. The results of the inflight and postflight testing are considered. The observed deviation between VOR SP and head motion suggests that spatial transformation in the VOR occurred during adaptation to microgravity. It is considered that, although this spatial transformation might be due to a sensory bias, it may reflect central changes in the reference system used for spatial orientation in microgravity.
Two-photon calcium imaging from head-fixed Drosophila during optomotor walking behavior.
Seelig, Johannes D; Chiappe, M Eugenia; Lott, Gus K; Dutta, Anirban; Osborne, Jason E; Reiser, Michael B; Jayaraman, Vivek
2010-07-01
Drosophila melanogaster is a model organism rich in genetic tools to manipulate and identify neural circuits involved in specific behaviors. Here we present a technique for two-photon calcium imaging in the central brain of head-fixed Drosophila walking on an air-supported ball. The ball's motion is tracked at high resolution and can be treated as a proxy for the fly's own movements. We used the genetically encoded calcium sensor, GCaMP3.0, to record from important elements of the motion-processing pathway, the horizontal-system lobula plate tangential cells (LPTCs) in the fly optic lobe. We presented motion stimuli to the tethered fly and found that calcium transients in horizontal-system neurons correlated with robust optomotor behavior during walking. Our technique allows both behavior and physiology in identified neurons to be monitored in a genetic model organism with an extensive repertoire of walking behaviors.
Head Excursion of Restrained Human Volunteers and Hybrid III Dummies in Steady State Rollover Tests
Moffatt, Edward; Hare, Barry; Hughes, Raymond; Lewis, Lance; Iiyama, Hiroshi; Curzon, Anne; Cooper, Eddie
2003-01-01
Seatbelts provide substantial benefits in rollover crashes, yet occupants still receive head and neck injuries from contacting the vehicle roof interior when the roof exterior strikes the ground. Prior research has evaluated rollover restraint performance utilizing anthropomorphic test devices (dummies), but little dynamic testing has been done with human volunteers to learn how they move during rollovers. In this study, the vertical excursion of the head of restrained dummies and human subjects was measured in a vehicle being rotated about its longitudinal roll axis at roll rates from 180-to-360 deg/sec and under static inversion conditions. The vehicle’s restraint design was the commonly used 3-point seatbelt with continuous loop webbing and a sliding latch plate. This paper presents an analysis of the observed occupant motion and provides a comparison of dummy and human motion under similar test conditions. Thirty-five tests (eighteen static and seventeen dynamic) were completed using two different sizes of dummies and human subjects in both near and far-side roll directions. The research indicates that far-side rollovers cause the restrained test subjects to have greater head excursion than near-side rollovers, and that static inversion testing underestimates head excursion for far-side occupants. Human vertical head excursion of up to 200 mm was found at a roll rate of 220 deg/sec. Humans exhibit greater variability in head excursion in comparison to dummies. Transfer of seatbelt webbing through the latch plate did not correlate directly with differences in head excursion. PMID:12941241
Simulation of the effects of different pilot helmets on neck loading during air combat.
Mathys, R; Ferguson, S J
2012-09-21
New generation pilot helmets with mounted devices enhance the capabilities of pilots substantially. However, the additional equipment increases the helmet weight and shifts its center of mass forward. Two helmets with different mass properties were modeled to simulate their effects on the pilot's neck. A musculoskeletal computer model was used, with the methods of inverse dynamics and static optimization, to compute the muscle activations and joint reaction forces for a given range of quasi-static postures at various accelerations experienced during air combat. Head postures which induce much higher loads on the cervical spine than encountered in a neutral position could be identified. The increased weight and the forward shift of the center of mass of a new generation helmet lead to higher muscle activations and higher joint reaction loads over a wide range of head and neck movements. The muscle activations required to balance the head and neck in extreme postures increased the compressive force at the T1-C7 level substantially, while in a neutral posture the muscle activations remained low. The lateral neck muscles can reach activations of 100% and cause compressive joint forces up to 1100N during extensive rotations and extensions at high 'vertical' accelerations (Gz). The calculated values have to be interpreted with care as the model has not been validated. Nevertheless, this systematic analysis could separate the effects of head posture, acceleration and helmet mass on neck loading. More reliable data about mass properties and muscle morphometry with a more detailed motion analysis would help to refine the existing model. Copyright © 2012 Elsevier Ltd. All rights reserved.
Rhodin, M; Persson-Sjodin, E; Egenvall, A; Serra Bragança, F M; Pfau, T; Roepstorff, L; Weishaupt, M A; Thomsen, M H; van Weeren, P R; Hernlund, E
2018-04-15
The main criteria for lameness assessment in horses are head movement for forelimb lameness and pelvic movement for hindlimb lameness. However, compensatory head nod in horses with primary hindlimb lameness is a well-known phenomenon. This compensatory head nod movement can be easily misinterpreted as a sign of primary ipsilateral forelimb lameness. Therefore, discriminating compensatory asymmetries from primary directly pain-related movement asymmetries is a prerequisite for successful lameness assessment. To investigate the association between head, withers and pelvis movement asymmetry in horses with induced forelimb and hindlimb lameness. Experimental study. In 10 clinically sound Warmblood riding horses, forelimb and hindlimb lameness were induced using a sole pressure model. The horses were then trotted on a treadmill. Three-dimensional optical motion capture was used to collect kinematic data from reflective markers attached to the poll, withers and tubera sacrale. The magnitude and side (left or right) of the following symmetry parameters, vertical difference in minimum position, maximum position and range-up were calculated for head, withers, and pelvis. Mixed models were used to analyse data from induced forelimb and hindlimb lameness. For each mm increase in pelvic asymmetry in response to hindlimb lameness induction, withers movement asymmetry increased by 0.35-0.55 mm, but towards the contralateral side. In induced forelimb lameness, for each mm increase in head movement asymmetry, withers movement asymmetry increased by 0.05-0.10 mm, in agreement with the head movement asymmetry direction, both indicating lameness in the induced forelimb. Results must be confirmed in clinically lame horses trotting overground. The vertical asymmetry pattern of the withers discriminated a head nod associated with true forelimb lameness from the compensatory head movement asymmetry caused by primary hindlimb lameness. Measuring movement symmetry of the withers may, thus, aid in determining primary lameness location. © 2018 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.
ERIC Educational Resources Information Center
Flecken, Monique; Carroll, Mary; Weimar, Katja; Von Stutterheim, Christiane
2015-01-01
The typological contrast between verb- and satellite-framed languages (Talmy, 1985) has set the basis for many empirical studies on L2 acquisition. The current analysis goes beyond this typology by looking in detail at the conceptualization of the path of motion in a motion event. We take as a starting point the cognitive salience of specific…
The use of virtual reality technology in the treatment of anxiety and other psychiatric disorders
Maples-Keller, Jessica L.; Bunnell, Brian E.; Kim, Sae-Jin; Rothbaum, Barbara O.
2016-01-01
Virtual reality, or VR, allows users to experience a sense of presence in a computer-generated three-dimensional environment. Sensory information is delivered through a head mounted display and specialized interface devices. These devices track head movements so that the movements and images change in a natural way with head motion, allowing for a sense of immersion. VR allows for controlled delivery of sensory stimulation via the therapist and is a convenient and cost-effective treatment. The primary focus of this article is to review the available literature regarding the effectiveness of incorporating VR within the psychiatric treatment of a wide range of psychiatric disorders, with a specific focus on exposure-based intervention for anxiety disorders. A systematic literature search was conducted in order to identify studies implementing VR based treatment for anxiety or other psychiatric disorders. This review will provide an overview of the history of the development of VR based technology and its use within psychiatric treatment, an overview of the empirical evidence for VR based treatment, the benefits for using VR for psychiatric research and treatment, recommendations for how to incorporate VR into psychiatric care, and future directions for VR based treatment and clinical research. PMID:28475502
Treatment of proximal ulna and olecranon fractures by dorsal plating.
Kloen, Peter; Buijze, Geert A
2009-12-01
Anatomic reconstruction of proximal ulna and olecranon fractures allowing early mobilization and prevention of ulnohumeral arthritis. Comminuted olecranon or proximal ulna fractures (including Monteggia fractures), olecranon fractures extending distally from the coronoid process, nonunions of the proximal ulna, segmental fractures of the proximal ulna extending into the shaft, fractures of the proximal ulna associated with a coronoid fracture. Patients in poor general condition. Soft-tissue defects around the elbow preventing wound closure over the plate. Pediatric fractures with open growth plates where screws would cross the physis. Posterior approach to the elbow. Hinging the fracture site open by extension of the proximal fragment based on triceps insertion. Fracture involvement of the coronoid with a large displaced fracture fragment can generally be reduced through the fracture side. Reconstruction with temporary Kirschner wires. Fixation by placing a (precontoured) plate around the tip of the olecranon with a long intramedullary screw and orthogonal (uni)cortical screws in the shaft. Radial head pathology can be addressed - if needed - through the same incision. Internal fixation, resection or prosthetic replacement of the radial head is done based on injury pattern/stability. Functional rehabilitation using active assisted range of motion of the elbow may be started immediately out of splint. Posterior splint for 7-10 days to allow wound healing. Between 2003 and July 2008, 26 patients were treated with posterior plating of the proximal ulna and olecranon using this strategy. There were 23 acute fractures (of which one was referred for revision after suboptimal fixation a few days earlier), one nonunion that became traumatized, and two nascent malunions. A midline posterior approach allowed addressing both ulna and radial head pathology. The plate was contoured to wrap around the olecranon. All fractures healed. There were one postoperative infection, one transient ulnar neuropathy, one transient radial neuropathy, and one nonresolving ulnar/median neuropathy in a complex upper extremity injury. At follow-up after an average of 18 months, range of motion was on average 132 degrees /18 degrees of flexion/extension, and 75 degrees /70 degrees of pronation/supination. All fractures had healed at an average of 4.8 months. Ten patients had their hardware removed.
Aidlen, Jeremy T; Glick, Sara; Silverman, Kenneth; Silverman, Harvey F; Luks, Francois I
2009-08-01
Light-weight, low-profile, and high-resolution head-mounted displays (HMDs) now allow personalized viewing, of a laparoscopic image. The advantages include unobstructed viewing, regardless of position at the operating table, and the possibility to customize the image (i.e., enhanced reality, picture-in-picture, etc.). The bright image display allows use in daylight surroundings and the low profile of the HMD provides adequate peripheral vision. Theoretic disadvantages include reliance for all on the same image capture and anticues (i.e., reality disconnect) when the projected image remains static, despite changes in head position. This can lead to discomfort and even nausea. We have developed a prototype of interactive laparoscopic image display that allows hands-free control of the displayed image by changes in spatial orientation of the operator's head. The prototype consists of an HMD, a spatial orientation device, and computer software to enable hands-free panning and zooming of a video-endoscopic image display. The spatial orientation device uses magnetic fields created by a transmitter and receiver, each containing three orthogonal coils. The transmitter coils are efficiently driven, using USB power only, by a newly developed circuit, each at a unique frequency. The HMD-mounted receiver system links to a commercially available PC-interface PCI-bus sound card (M-Audiocard Delta 44; Avid Technology, Tewksbury, MA). Analog signals at the receiver are filtered, amplified, and converted to digital signals, which are processed to control the image display. The prototype uses a proprietary static fish-eye lens and software for the distortion-free reconstitution of any portion of the captured image. Left-right and up-down motions of the head (and HMD) produce real-time panning of the displayed image. Motion of the head toward, or away from, the transmitter causes real-time zooming in or out, respectively, of the displayed image. This prototype of the interactive HMD allows hands-free, intuitive control of the laparoscopic field, independent of the captured image.
Medrea, Ioana
2013-01-01
The mouse has become an important model system for studying the cellular basis of learning and coding of heading by the vestibular system. Here we recorded from single neurons in the vestibular nuclei to understand how vestibular pathways encode self-motion under natural conditions, during which proprioceptive and motor-related signals as well as vestibular inputs provide feedback about an animal's movement through the world. We recorded neuronal responses in alert behaving mice focusing on a group of neurons, termed vestibular-only cells, that are known to control posture and project to higher-order centers. We found that the majority (70%, n = 21/30) of neurons were bimodal, in that they responded robustly to passive stimulation of proprioceptors as well as passive stimulation of the vestibular system. Additionally, the linear summation of a given neuron's vestibular and neck sensitivities predicted well its responses when both stimuli were applied simultaneously. In contrast, neuronal responses were suppressed when the same motion was actively generated, with the one striking exception that the activity of bimodal neurons similarly and robustly encoded head on body position in all conditions. Our results show that proprioceptive and motor-related signals are combined with vestibular information at the first central stage of vestibular processing in mice. We suggest that these results have important implications for understanding the multisensory integration underlying accurate postural control and the neural representation of directional heading in the head direction cell network of mice. PMID:24089394
Test suite for image-based motion estimation of the brain and tongue
NASA Astrophysics Data System (ADS)
Ramsey, Jordan; Prince, Jerry L.; Gomez, Arnold D.
2017-03-01
Noninvasive analysis of motion has important uses as qualitative markers for organ function and to validate biomechanical computer simulations relative to experimental observations. Tagged MRI is considered the gold standard for noninvasive tissue motion estimation in the heart, and this has inspired multiple studies focusing on other organs, including the brain under mild acceleration and the tongue during speech. As with other motion estimation approaches, using tagged MRI to measure 3D motion includes several preprocessing steps that affect the quality and accuracy of estimation. Benchmarks, or test suites, are datasets of known geometries and displacements that act as tools to tune tracking parameters or to compare different motion estimation approaches. Because motion estimation was originally developed to study the heart, existing test suites focus on cardiac motion. However, many fundamental differences exist between the heart and other organs, such that parameter tuning (or other optimization) with respect to a cardiac database may not be appropriate. Therefore, the objective of this research was to design and construct motion benchmarks by adopting an "image synthesis" test suite to study brain deformation due to mild rotational accelerations, and a benchmark to model motion of the tongue during speech. To obtain a realistic representation of mechanical behavior, kinematics were obtained from finite-element (FE) models. These results were combined with an approximation of the acquisition process of tagged MRI (including tag generation, slice thickness, and inconsistent motion repetition). To demonstrate an application of the presented methodology, the effect of motion inconsistency on synthetic measurements of head- brain rotation and deformation was evaluated. The results indicated that acquisition inconsistency is roughly proportional to head rotation estimation error. Furthermore, when evaluating non-rigid deformation, the results suggest that inconsistent motion can yield "ghost" shear strains, which are a function of slice acquisition viability as opposed to a true physical deformation.
Test Suite for Image-Based Motion Estimation of the Brain and Tongue
Ramsey, Jordan; Prince, Jerry L.; Gomez, Arnold D.
2017-01-01
Noninvasive analysis of motion has important uses as qualitative markers for organ function and to validate biomechanical computer simulations relative to experimental observations. Tagged MRI is considered the gold standard for noninvasive tissue motion estimation in the heart, and this has inspired multiple studies focusing on other organs, including the brain under mild acceleration and the tongue during speech. As with other motion estimation approaches, using tagged MRI to measure 3D motion includes several preprocessing steps that affect the quality and accuracy of estimation. Benchmarks, or test suites, are datasets of known geometries and displacements that act as tools to tune tracking parameters or to compare different motion estimation approaches. Because motion estimation was originally developed to study the heart, existing test suites focus on cardiac motion. However, many fundamental differences exist between the heart and other organs, such that parameter tuning (or other optimization) with respect to a cardiac database may not be appropriate. Therefore, the objective of this research was to design and construct motion benchmarks by adopting an “image synthesis” test suite to study brain deformation due to mild rotational accelerations, and a benchmark to model motion of the tongue during speech. To obtain a realistic representation of mechanical behavior, kinematics were obtained from finite-element (FE) models. These results were combined with an approximation of the acquisition process of tagged MRI (including tag generation, slice thickness, and inconsistent motion repetition). To demonstrate an application of the presented methodology, the effect of motion inconsistency on synthetic measurements of head-brain rotation and deformation was evaluated. The results indicated that acquisition inconsistency is roughly proportional to head rotation estimation error. Furthermore, when evaluating non-rigid deformation, the results suggest that inconsistent motion can yield “ghost” shear strains, which are a function of slice acquisition viability as opposed to a true physical deformation. PMID:28781414
Let the Dogs Out: Using Bobble Head Toys to Explore Force and Motion.
ERIC Educational Resources Information Center
Foster, Andrea S.
2003-01-01
Introduces an activity in which students learn principles of force and motion, systems, and simple machines by exploring the best position of the dogs on the dashboard. Includes a sample lesson plan written in the five instructional models: (1) engagement; (2) exploration; (3) explanation; (4) elaboration; and (5) evaluation. (KHR)
Klier, Eliana M; Angelaki, Dora E; Hess, Bernhard J M
2005-07-01
Primates are able to localize a briefly flashed target despite intervening movements of the eyes, head, or body. This ability, often referred to as updating, requires extraretinal signals related to the intervening movement. With active roll rotations of the head from an upright position it has been shown that the updating mechanism is 3-dimensional, robust, and geometrically sophisticated. Here we examine whether such a rotational updating mechanism operates during passive motion both with and without inertial cues about head/body position in space. Subjects were rotated from either an upright or supine position, about a nasal-occipital axis, briefly shown a world-fixed target, rotated back to their original position, and then asked to saccade to the remembered target location. Using this paradigm, we tested subjects' abilities to update from various tilt angles (0, +/-30, +/-45, +/-90 degrees), to 8 target directions and 2 target eccentricities. In the upright condition, subjects accurately updated the remembered locations from all tilt angles independent of target direction or eccentricity. Slopes of directional errors versus tilt angle ranged from -0.011 to 0.15, and were significantly different from a slope of 1 (no compensation for head-in-space roll) and a slope of 0.9 (no compensation for eye-in-space roll). Because the eyes, head, and body were fixed throughout these passive movements, subjects could not use efference copies or neck proprioceptive cues to assess the amount of tilt, suggesting that vestibular signals and/or body proprioceptive cues suffice for updating. In the supine condition, where gravitational signals could not contribute, slopes ranged from 0.60 to 0.82, indicating poor updating performance. Thus information specifying the body's orientation relative to gravity is critical for maintaining spatial constancy and for distinguishing body-fixed versus world-fixed reference frames.
Baddoura, Ritta; Venture, Gentiane
2014-01-01
During an unannounced encounter between two humans and a proactive humanoid (NAO, Aldebaran Robotics), we study the dependencies between the human partners' affective experience (measured via the answers to a questionnaire) particularly regarding feeling familiar and feeling frightened, and their arm and head motion [frequency and smoothness using Inertial Measurement Units (IMU)]. NAO starts and ends its interaction with its partners by non-verbally greeting them hello (bowing) and goodbye (moving its arm). The robot is invested with a real and useful task to perform: handing each participant an envelope containing a questionnaire they need to answer. NAO's behavior varies from one partner to the other (Smooth with X vs. Resisting with Y). The results show high positive correlations between feeling familiar while interacting with the robot and: the frequency and smoothness of the human arm movement when waving back goodbye, as well as the smoothness of the head during the whole encounter. Results also show a negative dependency between feeling frightened and the frequency of the human arm movement when waving back goodbye. The principal component analysis (PCA) suggests that, in regards to the various motion measures examined in this paper, the head smoothness and the goodbye gesture frequency are the most reliable measures when it comes to considering the familiar experienced by the participants. The PCA also points out the irrelevance of the goodbye motion frequency when investigating the participants' experience of fear in its relation to their motion characteristics. The results are discussed in light of the major findings of studies on body movements and postures accompanying specific emotions.
Ishida, Hisashi; Matsumoto, Atsushi
2014-01-01
To understand the mechanism of reverse tRNA translocation in the ribosome, all-atom molecular dynamics simulations of the ribosome-tRNAs-mRNA-EFG complex were performed. The complex at the post-translocational state was directed towards the translocational and pre-translocational states by fitting the complex into cryo-EM density maps. Between a series of the fitting simulations, umbrella sampling simulations were performed to obtain the free-energy landscape. Multistep structural changes, such as a ratchet-like motion and rotation of the head of the small subunit were observed. The free-energy landscape showed that there were two main free-energy barriers: one between the post-translocational and intermediate states, and the other between the pre-translocational and intermediate states. The former corresponded to a clockwise rotation, which was coupled to the movement of P-tRNA over the P/E-gate made of G1338, A1339 and A790 in the small subunit. The latter corresponded to an anticlockwise rotation of the head, which was coupled to the location of the two tRNAs in the hybrid state. This indicates that the coupled motion of the head rotation and tRNA translocation plays an important role in opening and closing of the P/E-gate during the ratchet-like movement in the ribosome. Conformational change of EF-G was interpreted to be the result of the combination of the external motion by L12 around an axis passing near the sarcin-ricin loop, and internal hinge-bending motion. These motions contributed to the movement of domain IV of EF-G to maintain its interaction with A/P-tRNA. PMID:24999999
Baddoura, Ritta; Venture, Gentiane
2014-01-01
During an unannounced encounter between two humans and a proactive humanoid (NAO, Aldebaran Robotics), we study the dependencies between the human partners' affective experience (measured via the answers to a questionnaire) particularly regarding feeling familiar and feeling frightened, and their arm and head motion [frequency and smoothness using Inertial Measurement Units (IMU)]. NAO starts and ends its interaction with its partners by non-verbally greeting them hello (bowing) and goodbye (moving its arm). The robot is invested with a real and useful task to perform: handing each participant an envelope containing a questionnaire they need to answer. NAO's behavior varies from one partner to the other (Smooth with X vs. Resisting with Y). The results show high positive correlations between feeling familiar while interacting with the robot and: the frequency and smoothness of the human arm movement when waving back goodbye, as well as the smoothness of the head during the whole encounter. Results also show a negative dependency between feeling frightened and the frequency of the human arm movement when waving back goodbye. The principal component analysis (PCA) suggests that, in regards to the various motion measures examined in this paper, the head smoothness and the goodbye gesture frequency are the most reliable measures when it comes to considering the familiar experienced by the participants. The PCA also points out the irrelevance of the goodbye motion frequency when investigating the participants' experience of fear in its relation to their motion characteristics. The results are discussed in light of the major findings of studies on body movements and postures accompanying specific emotions. PMID:24688466
Ishida, Hisashi; Matsumoto, Atsushi
2014-01-01
To understand the mechanism of reverse tRNA translocation in the ribosome, all-atom molecular dynamics simulations of the ribosome-tRNAs-mRNA-EFG complex were performed. The complex at the post-translocational state was directed towards the translocational and pre-translocational states by fitting the complex into cryo-EM density maps. Between a series of the fitting simulations, umbrella sampling simulations were performed to obtain the free-energy landscape. Multistep structural changes, such as a ratchet-like motion and rotation of the head of the small subunit were observed. The free-energy landscape showed that there were two main free-energy barriers: one between the post-translocational and intermediate states, and the other between the pre-translocational and intermediate states. The former corresponded to a clockwise rotation, which was coupled to the movement of P-tRNA over the P/E-gate made of G1338, A1339 and A790 in the small subunit. The latter corresponded to an anticlockwise rotation of the head, which was coupled to the location of the two tRNAs in the hybrid state. This indicates that the coupled motion of the head rotation and tRNA translocation plays an important role in opening and closing of the P/E-gate during the ratchet-like movement in the ribosome. Conformational change of EF-G was interpreted to be the result of the combination of the external motion by L12 around an axis passing near the sarcin-ricin loop, and internal hinge-bending motion. These motions contributed to the movement of domain IV of EF-G to maintain its interaction with A/P-tRNA.
Point-of-care ultrasound facilitates diagnosing a posterior shoulder dislocation.
Mackenzie, David C; Liebmann, Otto
2013-05-01
Posterior shoulder dislocation is an uncommon disruption of the glenohumeral joint. Risk factors include seizure, electric shock, and underlying instabilities of the shoulder joint. A 27-year-old man with a history of recurrent posterior shoulder dislocation presented to the Emergency Department with sudden shoulder pain and reduced range of motion about the shoulder after abducting and internally rotating his arm. Radiographs did not show fracture or dislocation. The treating physician suspected an occult posterior shoulder dislocation, but wanted to avoid performing a computed tomography scan of the shoulder, as the patient had undergone numerous scans during the evaluation of similar complaints. Instead, a point-of-care ultrasound was performed, demonstrating posterior displacement of the humeral head relative to the glenoid rim, confirming the presence of a posterior shoulder dislocation. The patient received procedural sedation, and the shoulder was reduced with real-time ultrasound visualization. The patient tolerated the procedure well, and had decreased pain and improved range of motion. He was discharged with a sling, swathe, and orthopedic follow-up. Point-of-care ultrasound of the shoulder may be used to demonstrate posterior shoulder dislocation. This may have particular utility in the setting of non-diagnostic radiographs. Copyright © 2013. Published by Elsevier Inc.
Liquefaction at Oceano, California, during the 2003 San Simeon earthquake
Holzer, T.L.; Noce, T.E.; Bennett, M.J.; Tinsley, J. C.; Rosenberg, L.I.
2005-01-01
The 2003 M 6.5 San Simeon, California, earthquake caused liquefaction-induced lateral spreading at Oceano at an unexpectedly large distance from the seismogenic rupture. We conclude that the liquefaction was caused by ground motion that was enhanced by both rupture directivity in the mainshock and local site amplification by unconsolidated fine-grained deposits. Liquefaction occurred in sandy artificial fill and undisturbed eolian sand and fluvial deposits. The largest and most damaging lateral spread was caused by liquefaction of artificial fill; the head of this lateral spread coincided with the boundary between the artificial fill and undisturbed eolian sand deposits. Values of the liquefaction potential index, in general, were greater than 5 at liquefaction sites, the threshold value that has been proposed for liquefaction hazard mapping. Although the mainshock ground motion at Oceano was not recorded, peak ground acceleration was estimated to range from 0.25 and 0.28g on the basis of the liquefaction potential index and aftershock recordings. The estimates fall within the range of peak ground acceleration values associated with the modified Mercalli intensity = VII reported at the U.S. Geological Survey (USGS) "Did You Feel It?" web site.
Song, Tianxiao; Wang, Xueyun; Liang, Wenwei; Xing, Li
2018-05-14
Benefiting from frame structure, RINS can improve the navigation accuracy by modulating the inertial sensor errors with proper rotation scheme. In the traditional motor control method, the measurements of the photoelectric encoder are always adopted to drive inertial measurement unit (IMU) to rotate. However, when carrier conducts heading motion, the inertial sensor errors may no longer be zero-mean in navigation coordinate. Meanwhile, some high-speed carriers like aircraft need to roll a certain angle to balance the centrifugal force during the heading motion, which may result in non-negligible coupling errors, caused by the FOG installation errors and scale factor errors. Moreover, the error parameters of FOG are susceptible to the temperature and magnetic field, and the pre-calibration is a time-consuming process which is difficult to completely suppress the FOG-related errors. In this paper, an improved motor control method with the measurements of FOG is proposed to address these problems, with which the outer frame can insulate the carrier's roll motion and the inner frame can simultaneously achieve the rotary modulation on the basis of insulating the heading motion. The results of turntable experiments indicate that the navigation performance of dual-axis RINS has been significantly improved over the traditional method, which could still be maintained even with large FOG installation errors and scale factor errors, proving that the proposed method can relax the requirements for the accuracy of FOG-related errors.
Yao, Nailin; Winkler, Anderson M; Barrett, Jennifer; Book, Gregory A; Beetham, Tamara; Horseman, Rachel; Leach, Olivia; Hodgson, Karen; Knowles, Emma E; Mathias, Samuel; Stevens, Michael C; Assaf, Michal; van Erp, Theo G M; Pearlson, Godfrey D; Glahn, David C
2017-08-01
Despite over 400 peer-reviewed structural MRI publications documenting neuroanatomic abnormalities in bipolar disorder and schizophrenia, the confounding effects of head motion and the regional specificity of these defects are unclear. Using a large cohort of individuals scanned on the same research dedicated MRI with broadly similar protocols, we observe reduced cortical thickness indices in both illnesses, though less pronounced in bipolar disorder. While schizophrenia (n = 226) was associated with wide-spread surface area reductions, bipolar disorder (n = 227) and healthy comparison subjects (n = 370) did not differ. We replicate earlier reports that head motion (estimated from time-series data) influences surface area and cortical thickness measurements and demonstrate that motion influences a portion, but not all, of the observed between-group structural differences. Although the effect sizes for these differences were small to medium, when global indices were covaried during vertex-level analyses, between-group effects became nonsignificant. This analysis raises doubts about the regional specificity of structural brain changes, possible in contrast to functional changes, in affective and psychotic illnesses as measured with current imaging technology. Given that both schizophrenia and bipolar disorder showed cortical thickness reductions, but only schizophrenia showed surface area changes, and assuming these measures are influenced by at least partially unique sets of biological factors, then our results could indicate some degree of specificity between bipolar disorder and schizophrenia. Hum Brain Mapp 38:3757-3770, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Shen, Yiru; Salley, James; Muth, Eric; Hoover, Adam
2017-01-01
This paper describes a study to test the accuracy of a method that tracks wrist motion during eating to detect and count bites. The purpose was to assess its accuracy across demographic (age, gender, ethnicity) and bite (utensil, container, hand used, food type) variables. Data were collected in a cafeteria under normal eating conditions. A total of 271 participants ate a single meal while wearing a watch-like device to track their wrist motion. Video was simultaneously recorded of each participant and subsequently reviewed to determine the ground truth times of bites. Bite times were operationally defined as the moment when food or beverage was placed into the mouth. Food and beverage choices were not scripted or restricted. Participants were seated in groups of 2–4 and were encouraged to eat naturally. A total of 24,088 bites of 374 different food and beverage items were consumed. Overall the method for automatically detecting bites had a sensitivity of 75% with a positive predictive value of 89%. A range of 62–86% sensitivity was found across demographic variables, with slower eating rates trending towards higher sensitivity. Variations in sensitivity due to food type showed a modest correlation with the total wrist motion during the bite, possibly due to an increase in head-towards-plate motion and decrease in hand-towards-mouth motion for some food types. Overall, the findings provide the largest evidence to date that the method produces a reliable automated measure of intake during unrestricted eating. PMID:28113994
NASA Technical Reports Server (NTRS)
Miller, Christopher; Peters, Brian; Feiveson, Alan; Bloomberg, Jacob
2011-01-01
Astronauts returning from spaceflight experience neurovestibular disturbances during head movements and attempt to mitigate them by limiting head motion. Analyses to date of the head movements made during walking have concentrated on amplitude and variability measures extracted from ensemble averages of individual gait cycles. Phase shifts within each gait cycle can be determined by functional data analysis through the computation of time-warping functions. Large, localized variations in the timing of peaks in head kinematics may indicate changes in coordination. The purpose of this study was to determine timing changes in head pitch acceleration of astronauts during treadmill walking before and after flight. Six astronauts (5M/1F; age = 43.5+/-6.4yr) participated in the study. Subjects walked at 1.8 m/sec (4 mph) on a motorized treadmill while reading optotypes displayed on a computer screen 4 m in front of their eyes. Three-dimensional motion of the subject s head was recorded with an Inertial Measurement Unit (IMU) device. Data were recorded twice before flight and four times after landing. The head pitch acceleration was calculated by taking the time derivative of the pitch velocity data from the IMU. Data for each session with each subject were time-normalized into gait cycles, then registered to align significant features and create a mean curve. The mean curves of each postflight session for each subject were re-registered based on their preflight mean curve to create time-warping functions. The root mean squares (RMS) of these warping functions were calculated to assess the deviation of head pitch acceleration mean curves in each postflight session from the preflight mean curve. After landing, most crewmembers exhibited localized shifts within their head pitch acceleration regimes, with the greatest deviations in RMS occurring on landing day or 1 day after landing. These results show that the alteration of head pitch coordination due to spaceflight may be assessed using an analysis of time-warping functions.
Talamo, Giampaolo; Angtuaco, Edgardo; Walker, Ronald C; Dong, Li; Miceli, Marisa H; Zangari, Maurizio; Tricot, Guido; Barlogie, Bart; Anaissie, Elias
2005-08-01
To assess the prevalence, time of onset, risk factors, and outcome of avascular necrosis (AVN) of bone in patients with multiple myeloma undergoing antineoplastic therapy. A total of 553 consecutive assessable patients were enrolled onto a treatment protocol consisting of dexamethasone-containing induction chemotherapy, autologous stem-cell transplantation, consolidation chemotherapy, and maintenance with interferon alfa. Patients were randomly assigned to receive thalidomide (269 patients) or no thalidomide (284 patients) throughout the study period. With a median follow-up of 33 months (range, 5 to 114 months), AVN of the femoral head(s) developed in 49 patients (9%). Median time to onset of AVN was 12 months (range, 2 to 41 months). Three risk factors for AVN were identified by multivariate analysis: cumulative dexamethasone dose (odds ratio [OR], 1.028; 95% CI, 1.012 to 1.044; P = .0006 [per 40 mg dexamethasone]), male sex (OR, 0.390; 95% CI, 0.192 to 0.790; P = .009), and younger age (OR, 0.961; 95% CI, 0.934 to 0.991 per year; P = .0122). Thalidomide-treated patients had a prevalence of AVN similar to that of the control group (8% v 10%, respectively; P = .58). AVN-related pain and limited range of motion of the affected joint were present in only nine and four patients, respectively, and four patients underwent hip replacement because of AVN. Fluorine-18 fluorodeoxyglucose positron emission tomography failed to detect abnormal uptake in the AVN-affected bones. AVN is a rare and usually asymptomatic complication during myeloma therapy. Cumulative dexamethasone dose, male sex, and younger age, but not thalidomide, increase the risk of AVN.
Free-to-Roll Testing of Airplane Models in Wind Tunnels
NASA Technical Reports Server (NTRS)
Capone, Francis J.; Owens, D. Bruce; Hall, Robert M.
2007-01-01
A free-to-roll (FTR) test technique and test rig make it possible to evaluate both the transonic performance and the wingdrop/ rock behavior of a high-strength airplane model in a single wind-tunnel entry. The free-to-roll test technique is a single degree-of-motion method in which the model is free to roll about the longitudinal axis. The rolling motion is observed, recorded, and analyzed to gain insight into wing-drop/rock behavior. Wing-drop/rock is one of several phenomena symptomatic of abrupt wing stall. FTR testing was developed as part of the NASA/Navy Abrupt Wing Stall Program, which was established for the purposes of understanding and preventing significant unexpected and uncommanded (thus, highly undesirable) lateral-directional motions associated with wing-drop/rock, which have been observed mostly in fighter airplanes under high-subsonic and transonic maneuvering conditions. Before FTR testing became available, wingrock/ drop behavior of high-performance airplanes undergoing development was not recognized until flight testing. FTR testing is a reliable means of detecting, and evaluating design modifications for reducing or preventing, very complex abrupt wing stall phenomena in a ground facility prior to flight testing. The FTR test rig was designed to replace an older sting attachment butt, such that a model with its force balance and support sting could freely rotate about the longitudinal axis. The rig (see figure) includes a rotary head supported in a stationary head with a forward spherical roller bearing and an aft needle bearing. Rotation is amplified by a set of gears and measured by a shaft-angle resolver; the roll angle can be resolved to within 0.067 degrees at a rotational speed up to 1,000 degrees/s. An assembly of electrically actuated brakes between the rotary and stationary heads can be used to hold the model against a rolling torque at a commanded roll angle. When static testing is required, a locking bar is used to fix the rotating head rigidly to the stationary head. Switching between the static and FTR test modes takes only about 30 minutes. The FTR test rig was originally mounted in a 16-ft (approximately 4.0-m) transonic wind tunnel, but could just as well be adapted to use in any large wind tunnel. In one series of tests on the FTR rig, static and dynamic characteristics of models of four different fighter airplanes were measured. Two of the models exhibited uncommanded lateral motions; the other two did not. A figure of merit was developed to discern the severity of lateral motions. Using this figure of merit, it was shown that the FTR test technique enabled identification of conditions under which the uncommanded lateral motions occurred. The wind-tunnel conditions thus identified were found to be correlated with flight conditions under which the corresponding full-size airplanes exhibited uncommanded lateral motions.
Towards frameless maskless SRS through real-time 6DoF robotic motion compensation.
Belcher, Andrew H; Liu, Xinmin; Chmura, Steven; Yenice, Kamil; Wiersma, Rodney D
2017-11-13
Stereotactic radiosurgery (SRS) uses precise dose placement to treat conditions of the CNS. Frame-based SRS uses a metal head ring fixed to the patient's skull to provide high treatment accuracy, but patient comfort and clinical workflow may suffer. Frameless SRS, while potentially more convenient, may increase uncertainty of treatment accuracy and be physiologically confining to some patients. By incorporating highly precise robotics and advanced software algorithms into frameless treatments, we present a novel frameless and maskless SRS system where a robot provides real-time 6DoF head motion stabilization allowing positional accuracies to match or exceed those of traditional frame-based SRS. A 6DoF parallel kinematics robot was developed and integrated with a real-time infrared camera in a closed loop configuration. A novel compensation algorithm was developed based on an iterative closest-path correction approach. The robotic SRS system was tested on six volunteers, whose motion was monitored and compensated for in real-time over 15 min simulated treatments. The system's effectiveness in maintaining the target's 6DoF position within preset thresholds was determined by comparing volunteer head motion with and without compensation. Comparing corrected and uncorrected motion, the 6DoF robotic system showed an overall improvement factor of 21 in terms of maintaining target position within 0.5 mm and 0.5 degree thresholds. Although the system's effectiveness varied among the volunteers examined, for all volunteers tested the target position remained within the preset tolerances 99.0% of the time when robotic stabilization was used, compared to 4.7% without robotic stabilization. The pre-clinical robotic SRS compensation system was found to be effective at responding to sub-millimeter and sub-degree cranial motions for all volunteers examined. The system's success with volunteers has demonstrated its capability for implementation with frameless and maskless SRS treatments, potentially able to achieve the same or better treatment accuracies compared to traditional frame-based approaches.
Towards frameless maskless SRS through real-time 6DoF robotic motion compensation
NASA Astrophysics Data System (ADS)
Belcher, Andrew H.; Liu, Xinmin; Chmura, Steven; Yenice, Kamil; Wiersma, Rodney D.
2017-12-01
Stereotactic radiosurgery (SRS) uses precise dose placement to treat conditions of the CNS. Frame-based SRS uses a metal head ring fixed to the patient’s skull to provide high treatment accuracy, but patient comfort and clinical workflow may suffer. Frameless SRS, while potentially more convenient, may increase uncertainty of treatment accuracy and be physiologically confining to some patients. By incorporating highly precise robotics and advanced software algorithms into frameless treatments, we present a novel frameless and maskless SRS system where a robot provides real-time 6DoF head motion stabilization allowing positional accuracies to match or exceed those of traditional frame-based SRS. A 6DoF parallel kinematics robot was developed and integrated with a real-time infrared camera in a closed loop configuration. A novel compensation algorithm was developed based on an iterative closest-path correction approach. The robotic SRS system was tested on six volunteers, whose motion was monitored and compensated for in real-time over 15 min simulated treatments. The system’s effectiveness in maintaining the target’s 6DoF position within preset thresholds was determined by comparing volunteer head motion with and without compensation. Comparing corrected and uncorrected motion, the 6DoF robotic system showed an overall improvement factor of 21 in terms of maintaining target position within 0.5 mm and 0.5 degree thresholds. Although the system’s effectiveness varied among the volunteers examined, for all volunteers tested the target position remained within the preset tolerances 99.0% of the time when robotic stabilization was used, compared to 4.7% without robotic stabilization. The pre-clinical robotic SRS compensation system was found to be effective at responding to sub-millimeter and sub-degree cranial motions for all volunteers examined. The system’s success with volunteers has demonstrated its capability for implementation with frameless and maskless SRS treatments, potentially able to achieve the same or better treatment accuracies compared to traditional frame-based approaches.
Comparison of three different techniques for camera and motion control of a teleoperated robot.
Doisy, Guillaume; Ronen, Adi; Edan, Yael
2017-01-01
This research aims to evaluate new methods for robot motion control and camera orientation control through the operator's head orientation in robot teleoperation tasks. Specifically, the use of head-tracking in a non-invasive way, without immersive virtual reality devices was combined and compared with classical control modes for robot movements and camera control. Three control conditions were tested: 1) a condition with classical joystick control of both the movements of the robot and the robot camera, 2) a condition where the robot movements were controlled by a joystick and the robot camera was controlled by the user head orientation, and 3) a condition where the movements of the robot were controlled by hand gestures and the robot camera was controlled by the user head orientation. Performance, workload metrics and their evolution as the participants gained experience with the system were evaluated in a series of experiments: for each participant, the metrics were recorded during four successive similar trials. Results shows that the concept of robot camera control by user head orientation has the potential of improving the intuitiveness of robot teleoperation interfaces, specifically for novice users. However, more development is needed to reach a margin of progression comparable to a classical joystick interface. Copyright © 2016 Elsevier Ltd. All rights reserved.
The effects of SENSE on PROPELLER imaging.
Chang, Yuchou; Pipe, James G; Karis, John P; Gibbs, Wende N; Zwart, Nicholas R; Schär, Michael
2015-12-01
To study how sensitivity encoding (SENSE) impacts periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) image quality, including signal-to-noise ratio (SNR), robustness to motion, precision of motion estimation, and image quality. Five volunteers were imaged by three sets of scans. A rapid method for generating the g-factor map was proposed and validated via Monte Carlo simulations. Sensitivity maps were extrapolated to increase the area over which SENSE can be performed and therefore enhance the robustness to head motion. The precision of motion estimation of PROPELLER blades that are unfolded with these sensitivity maps was investigated. An interleaved R-factor PROPELLER sequence was used to acquire data with similar amounts of motion with and without SENSE acceleration. Two neuroradiologists independently and blindly compared 214 image pairs. The proposed method of g-factor calculation was similar to that provided by the Monte Carlo methods. Extrapolation and rotation of the sensitivity maps allowed for continued robustness of SENSE unfolding in the presence of motion. SENSE-widened blades improved the precision of rotation and translation estimation. PROPELLER images with a SENSE factor of 3 outperformed the traditional PROPELLER images when reconstructing the same number of blades. SENSE not only accelerates PROPELLER but can also improve robustness and precision of head motion correction, which improves overall image quality even when SNR is lost due to acceleration. The reduction of SNR, as a penalty of acceleration, is characterized by the proposed g-factor method. © 2014 Wiley Periodicals, Inc.
Hammoud, Sommer; Bedi, Asheesh; Voos, James E.; Mauro, Craig S.; Kelly, Bryan T.
2014-01-01
Context: In active individuals with femoroacetabular impingement (FAI), the resultant reduction in functional range of motion leads to high impaction loads at terminal ranges. These increased forces result in compensatory effects on bony and soft tissue structures within the hip joint and hemipelvis. An algorithm is useful in evaluating athletes with pre-arthritic, mechanical hip pain and associated compensatory disorders. Evidence Acquisition: A literature search was performed by a review of PubMed articles published from 1976 to 2013. Level of Evidence: Level 4. Results: Increased stresses across the bony hemipelvis result when athletes with FAI attempt to achieve supraphysiologic, terminal ranges of motion (ROM) through the hip joint required for athletic competition. This can manifest as pain within the pubic joint (osteitis pubis), sacroiliac joint, and lumbosacral spine. Subclinical posterior hip instability may result when attempts to increase hip flexion and internal rotation are not compensated for by increased motion through the hemipelvis. Prominence of the anterior inferior iliac spine (AIIS) at the level of the acetabular rim can result in impingement of the anterior hip joint capsule or iliocapsularis muscle origin against the femoral head-neck junction, resulting in a distinct form of mechanical hip impingement (AIIS subspine impingement). Iliopsoas impingement (IPI) has also been described as an etiology for anterior hip pain. IPI results in a typical 3-o’clock labral tear as well as an inflamed capsule in close proximity to the overlying iliopsoas tendon. Injury in athletic pubalgia occurs during high-energy twisting activities in which abnormal hip ROM and resultant pelvic motion lead to shearing across the pubic symphysis. Conclusion: Failure to recognize and address concomitant compensatory injury patterns associated with intra-articular hip pathology can result in significant disability and persistent symptoms in athletes with pre-arthritic, mechanical hip pain. Strength-of-Recommendation Taxonomy (SORT): B PMID:24587859
Head-Neck Biomechanics in Simulated Rear Impact
Yoganandan, Narayan; Pintar, Frank A.; Cusick, Joseph F.; Kleinberger, Michael
1998-01-01
The first objective of this study is to present an overview of the human cadaver studies aimed to determine the biomechanics of the head-neck in a simulated rear crash. The need for kinematic studies to better understand the mechanisms of load transfer to the human head-neck complex is emphasized. Based on this need, a methodology is developed to delineate the dynamic kinematics of the human head-neck complex. Intact human cadaver head-neck complexes were subjected to postero-anterior impact using a mini-sled pendulum device. The integrity of the soft tissues including the musculature and skin were maintained. The kinematic data were recorded using high-speed photography coupled with retroreflective targets placed at various regions of the human head-neck complex. The overall and segmental kinematics of the entire head-neck complex, and the localized facet joint motions were determined. During the initial stages of loading, a transient decoupling of the head occurred with respect to the neck exhibiting a lag of the cranium. The upper cervical spine-head undergoes local flexion concomitant with a lag of the head while the lower cervical spinal column is in local extension. This establishes a reverse curvature to the cervical head-neck complex. With continued loading, head motion ensues and approximately at the end of the loading phase, the entire head-neck complex is under the extension mode with a single curvature. In contrast, the lower cervical spine facet joint kinematics show varying compression and sliding. While both the anterior and posterior-most regions of the facet joint slide, the posterior-most region (mean: 2.84 mm) of the joint compresses more than the anterior-most (mean: 2.02 mm) region. These varying kinematics at the ends of the facet joint result in a pinching mechanism. These biomechanical kinematic findings may be correlated to the presence of headaches and neck pain (Lord, Bogduk et al. 1992; Barnsley, Lord et al. 1995), based on the unique human head-neck anatomy at the upper cervical spine region and the associated facet joint characteristics, and clinical studies.
Streepey, Jefferson W; Kenyon, Robert V; Keshner, Emily A
2007-01-01
We previously reported responses to induced postural instability in young healthy individuals viewing visual motion with a narrow (25 degrees in both directions) and wide (90 degrees and 55 degrees in the horizontal and vertical directions) field of view (FOV) as they stood on different sized blocks. Visual motion was achieved using an immersive virtual environment that moved realistically with head motion (natural motion) and translated sinusoidally at 0.1 Hz in the fore-aft direction (augmented motion). We observed that a subset of the subjects (steppers) could not maintain continuous stance on the smallest block when the virtual environment was in motion. We completed a posteriori analyses on the postural responses of the steppers and non-steppers that may inform us about the mechanisms underlying these differences in stability. We found that when viewing augmented motion with a wide FOV, there was a greater effect on the head and whole body center of mass and ankle angle root mean square (RMS) values of the steppers than of the non-steppers. FFT analyses revealed greater power at the frequency of the visual stimulus in the steppers compared to the non-steppers. Whole body COM time lags relative to the augmented visual scene revealed that the time-delay between the scene and the COM was significantly increased in the steppers. The increased responsiveness to visual information suggests a greater visual field-dependency of the steppers and suggests that the thresholds for shifting from a reliance on visual information to somatosensory information can differ even within a healthy population.
Countermanding eye-head gaze shifts in humans: marching orders are delivered to the head first.
Corneil, Brian D; Elsley, James K
2005-07-01
The countermanding task requires subjects to cancel a planned movement on appearance of a stop signal, providing insights into response generation and suppression. Here, we studied human eye-head gaze shifts in a countermanding task with targets located beyond the horizontal oculomotor range. Consistent with head-restrained saccadic countermanding studies, the proportion of gaze shifts on stop trials increased the longer the stop signal was delayed after target presentation, and gaze shift stop-signal reaction times (SSRTs: a derived statistic measuring how long it takes to cancel a movement) averaged approximately 120 ms across seven subjects. We also observed a marked proportion of trials (13% of all stop trials) during which gaze remained stable but the head moved toward the target. Such head movements were more common at intermediate stop signal delays. We never observed the converse sequence wherein gaze moved while the head remained stable. SSRTs for head movements averaged approximately 190 ms or approximately 70-75 ms longer than gaze SSRTs. Although our findings are inconsistent with a single race to threshold as proposed for controlling saccadic eye movements, movement parameters on stop trials attested to interactions consistent with a race model architecture. To explain our data, we tested two extensions to the saccadic race model. The first assumed that gaze shifts and head movements are controlled by parallel but independent races. The second model assumed that gaze shifts and head movements are controlled by a single race, preceded by terminal ballistic intervals not under inhibitory control, and that the head-movement branch is activated at a lower threshold. Although simulations of both models produced acceptable fits to the empirical data, we favor the second alternative as it is more parsimonious with recent findings in the oculomotor system. Using the second model, estimates for gaze and head ballistic intervals were approximately 25 and 90 ms, respectively, consistent with the known physiology of the final motor paths. Further, the threshold of the head movement branch was estimated to be 85% of that required to activate gaze shifts. From these results, we conclude that a commitment to a head movement is made in advance of gaze shifts and that the comparative SSRT differences result primarily from biomechanical differences inherent to eye and head motion.
1985-12-01
Despite the problems, drug therapy was seen as the easiest and most effective treatment. Some wartime research, primarily Canadian and Australian ...sickness was further supported by the Australians when they found that small head motions greatly contributed to the onset of motion sickness (46:20). It is...particularly noteworthy that one Australian , McIntyre, laid the groundwork for modern sensory conflict theory when he stated in 1941, "In most cases
Modafinil as a potential motion sickness countermeasure.
Hoyt, Robert E; Lawson, Benton D; McGee, Heather A; Strompolis, Melissa L; McClellan, Molly A
2009-08-01
Motion sickness adversely affects military air and sea operations. Medications help prevent motion sickness but are frequently associated with side effects. Better medications or combinations of medications are needed. Dextroamphetamine has documented anti-motion sickness effects but also has a potential for abuse. Modafinil is a relatively new central nervous system stimulant that has none of the drawbacks of dextroamphetamine, but has not been evaluated for the treatment of motion sickness. This double-blind, placebo-controlled study evaluated the anti-motion sickness efficacy of modafinil, alone or in combination with oral scopolamine. Moderate nausea was induced via a Coriolis cross-coupling stimulus. There were 60 participants who were assigned randomly to 1 of 3 conditions: 1) 2 placebo pills (DP); 2) modafinil plus placebo (MP); or 3) modafinil plus oral scopolamine (MS). The primary measure of drug efficacy was the number of head tilts tolerated upon reaching moderate nausea for 1 min without abatement. The combination of modafinil and scopolamine (MS) allowed subjects to tolerate significantly more head tilts than placebo, but modafinil alone (MP) failed to differ significantly from placebo (DP). No significant cognitive performance decrements were observed among the three experimental conditions. Modafinil was not found to be more effective than placebo. Further testing is recommended to determine whether the potentially promising combination of modafinil and scopolamine provides better efficacy or fewer side effects than scopolamine administered alone.
Coupling of Head and Body Movement with Motion of the Audible Environment
ERIC Educational Resources Information Center
Stoffregen, Thomas A.; Villard, Sebastien; Kim, ChungGon; Ito, Kiyohide; Bardy, Benoit G.
2009-01-01
The authors asked whether standing posture could be controlled relative to audible oscillation of the environment. Blindfolded sighted adults were exposed to acoustic flow in a moving room, and were asked to move so as to maintain a constant distance between their head and the room. Acoustic flow had direct (source) and indirect (reflected)…
Williams, Grace; Sarig-Bahat, Hilla; Williams, Katrina; Tyrrell, Ryan; Treleaven, Julia
2017-01-01
Research has consistently shown cervical kinematic impairments in subjects with persistent neck pain (NP). It could be reasoned that those with vestibular pathology (VP) may also have altered kinematics since vestibular stimulation via head movement can cause dizziness and visual disturbances. However, this has not been examined to date. This pilot study investigated changes in cervical kinematics between asymptomatic control, NP and VP subjects using a Virtual Reality (VR) system. It was hypothesised that there would be altered kinematics in VP subjects, which might be associated with dizziness and visual symptoms. Pilot cross sectional observational study. Twenty control, 14 VP and 20 NP subjects. Not applicable. Measures included questionnaires (neck disability index, pain on movement, dizziness and pain intensity, visual disturbances) and cervical kinematics (range, peak and mean velocity, smoothness, symmetry, and accuracy of cervical motion) using a virtual reality system. Results revealed significantly decreased mean velocity and symmetry of motion in both planes in those with NP but no differences in accuracy or range of motion. No significant differences were seen between VP subjects and asymptomatic controls. However, correlation analysis showed some moderate correlations between dizziness to selected kinematics in both the NP and the VP groups. These results support that cervical kinematics are altered in NP patients, with velocity most affected. There is potential for VP subjects to also have altered kinematics, especially those who experience dizziness. More research is required.
Rich, Margaret M; Schoenecker, Perry L
2013-03-01
Containment treatment is widely accepted in the management of Legg-Calvé-Perthes disease. Many reports indicate the need to regain hip motion before pelvic or femoral osteotomy, but have not indicated how osteotomy affected motion. Recent studies have suggested that osteotomy treatment of lateral pillar B hips may result in a higher proportion of spherical hips than those managed nonoperatively; however, outcomes for children older than 8 years of age or with pillar C involvement remain unsatisfactory. The records of all patients with a diagnosis of Legg-Calvé-Perthes disease seen at our facility from 1985 through 2001 were reviewed. Two hundred and thirteen patients (175 males, 38 females), average age 6.4 years (range, 2.6 to 11.3 y), with 240 involved hips in the necrotic or the fragmentation stage were managed under a protocol to restore and maintain satisfactory hip abduction with an adductor tenotomy and abduction cast, followed by daily hip range-of-motion exercises and an A-frame orthosis to facilitate the concentric position of the epiphysis within the acetabulum. Assessment included measurement of hip abduction, femoral head sphericity and congruence, presence of femoral neck deformity, limb-length inequality, and later reconstructive surgical procedures. Hips were grouped by lateral pillar class (12A, 113B, 115C) and evaluated at maturity using a modified Stulberg grade. All pillar A hips were spherically congruent. Of pillar B hips, 101 were spherically congruent, 8 were aspherical but congruent, and 4 were aspherical and incongruent. Of pillar C hips, 77 were spherically congruent, 26 were aspherical but congruent, and 12 were aspherical and incongruent. Age did not correlate with outcome. Hip abduction improved and was maintained in all groups. Treatment that restored and maintained hip range of motion along with the use of an A-frame orthosis resulted in a high proportion of spherically congruent hips for patients of all ages irrespective of the extent of disease. Seventy-eight percent of pillar B and C hips were spherically congruent hips at maturity; overall, 93% of hips were congruent. This regimen has supplanted all other methods of treatment at our institution. Level IV-case series.
Grzegorzewski, Andrzej; Synder, Marek; Kmieć, Krysztof; Krajewski, Karol; Polguj, Michał; Sibiński, Marcin
2013-01-01
The aim of the study was to retrospectively review results of operative treatment for coverage deficit of femoral head in children with severe epiphysis displacement in Legg-Calvé-Perthes (LCP) disease. The material included 23 shelf acetabuloplasty procedures for LCP disease. The average age at diagnosis was 8.1 years (range 4–12). Mean follow-up was 5.8 years (range from 2.2 to 11.2 years). Mean Reimer's index decreased statistically significantly from a mean of 32% before surgery to 10.0% at the last follow-up (P < 0.00001). The mean Wiberg center-edge angle increased also statistically significantly from a mean of 17.3° before procedure to 32.3° at the last follow-up (P < 0.00001). According to the Stulberg classification, type I was observed in 2, type II in 13, type III in 6, and type IV in 2 hips. There were no differences in the range of motion or leg length discrepancy in preoperative and postoperative standing. Partial, not significant, bone graft resorption was noted in 6 cases in the first 6–9 months after surgery. To conclude, shelf acetabuloplasty allows achieving good midterm results in the treatment of severe stages of LCP disease. The procedure improves coverage of femoral head and allows its remodelling. PMID:24377097
Riddoch, M Jane; Riveros, Rodrigo; Humphreys, Glyn W
2011-02-01
Patients with extinction show a characteristic impairment in the identification of objects when two items are presented simultaneously, typically reporting the ipsilesional item only. The effect is thought to be due to a spatial bias advantaging the ipsilesional item under conditions of competing concurrent stimulation. Action relations between objects can result in recovery from extinction as the object pair may be perceived as a single group rather than competing perceptual units. However, objects interacting together can also have implied motion. Here we test whether implied motion is necessary to generate recovery from extinction. We varied orthogonally whether animate and inanimate objects were paired together in positions related or unrelated to action. Implied motion was greater when an animate object was present than when both stimuli were inanimate. Despite this, recovery from extinction was greater when actions were shown between inanimate objects. We suggest that actions between inanimate objects are perceived more easily due to the surfaces of these stimuli being designed for functional goals (e.g., the flat surface of a hammer head is designed to hit the flattened head of a nail). Attention is sensitive to the fit between potential action and the functional properties of objects, and not just to implied motion between stimuli.
Effect of Spaceflight on Vestibulo-Ocular Reflexes (VORS) During Angular Head Motion
NASA Technical Reports Server (NTRS)
Tomko, David L.; Clifford, James O.; Hargens, Alan R. (Technical Monitor)
1996-01-01
Vestibulo-ocular reflexes (VORs) stabilize the eyes during head motion. During Earth-horizontal (E-H) pitch or roll rotations, canal and otolith stimuli occur together. In Earth-vertical (E-V) pitch or roll rotations, only canal signals occur. In cats and squirrel monkeys, pitch/roll VOR gains during E-H motion have been shown to be larger than during E-V motion, implying that otolith modulation plays a role in producing angular VORs (aVORs). The present experiments replicated this experiment in rhesus monkeys, and examined how spaceflight affected AVOR gain. During yaw, pitch and roll (0.5 - 1.0 Hz, 40-50 deg/s pk) motion, 3-d eye movements were recorded in four Rhesus monkeys using scleral search coils. Mean E-H and E-V pitch VOR gains were 0.85 and 0.71. Torsional VOR gains during E-H and E-V were 0.47 and 0.39. Gains are more compensatory during E-H pitch or roll. Two of the four monkeys flew for 11 days on the COSMOS 2229 Biosatellite. E-H pitch VOR gains were attenuated immediately (72 hrs) post-flight, with similar values to pre-flight E-V pitch gains. Horizontal yaw VOR gains were similar pre- and post-flight.
Furey, Matthew J; Sheps, David M; White, Neil J; Hildebrand, Kevin A
2013-05-01
Many investigators agree that 2 mm of articular displacement is a reasonable indication for open reduction and internal fixation of Mason type II fractures of the radial head. However, there is no evidence to support that this degree of articular displacement is predictive of poor outcomes in conservatively treated fractures. We hypothesized there would be no difference between conservatively treated radial head fractures with greater 2 mm of displacement and those with less than 2 mm of displacement in terms of patient-reported or clinical outcomes. We reviewed databases of all radial head fractures in our region. The primary outcomes were the Patient-Rated Elbow Evaluation and Disabilities of the Arm, Shoulder and Hand questionnaires. Secondary outcomes included radiologic radiocapitellar arthritis and range of motion (ROM) at follow-up. Postinjury treatment protocols, as well as patient factors, were examined for their effects on outcome. The results showed no significant difference in any outcome for conservatively treated radial head fractures with 2 mm (P = .8) or even 3 mm (P = .6) of articular displacement over a mean follow-up of 4.4 years. Early ROM and physiotherapy showed no significant differences in any outcome measure. Dominant hand injury showed no significant difference in patient-reported outcomes; however, ROM was significantly decreased on examination. This retrospective review suggests that fracture displacement of 2 to 3 mm is not necessarily an indication for surgical fixation in isolated fractures of the radial head. In addition, it appears that postinjury ROM/physiotherapy does not play a large role in improving patient outcome. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Gómez Álvarez, C B; Gustås, P; Bergh, A; Rhodin, M
2017-11-01
Compensatory limb loading has been studied in lame dogs; however, little is known about how these compensations relate to motion of the head and pelvis, assessment of which is an important component of lameness examinations. The aim of this study was to describe the patterns of vertical head and pelvic motion symmetry at the trot in dogs with induced supporting limb lameness in the forelimbs or hind limbs. Ten sound dogs were trotted on a treadmill before and after temporary induction of moderate lameness (grade 2/5) in each limb. Reflective markers were located on the head, pelvis and right forelimb, and kinematic data were captured with a motion capture system. Upper body symmetry parameters were calculated, including differences in the highest (HDmax) and in the lowest (HDmin) positions of the head, and in the highest (PDmax) and in the lowest (PDmin) positions of the mid-pelvis, with a value of zero indicating symmetry. The head was lowered more during the sound limb stance phase and lowered less during the lame limb stance phase in supporting forelimb lameness (HDmin: 4.6mm in dogs when sound, -18.3mm when left limb lameness was induced and 20.5mm when right limb lameness was induced). The mid-pelvis was lowered more during the sound limb stance phase and lowered and lifted less during the lame limb stance phase in supporting hind limb lameness (PDmin: 1mm in dogs when sound, -10.1mm in left limb lameness and 8.4mm in right limb lameness). The hip of the lame side, measured at the level of the greater trochanter, had an increased downwards displacement during the lame limb swing phase (-21mm in left hind limb lameness, P=0.005; 23.4mm in right hind limb lameness, P=0.007). Asymmetry in the lowering of the head or mid-pelvis is a more sensitive indicator of supporting forelimb and hind limb lameness, respectively, than asymmetry in the raising of the head. Increased displacement of the hip ('hip drop' of the lame side during its swing phase) is a good indicator of hind limb lameness in dogs. Copyright © 2017. Published by Elsevier Ltd.
Moving along the Mental Number Line: Interactions between Whole-Body Motion and Numerical Cognition
ERIC Educational Resources Information Center
Hartmann, Matthias; Grabherr, Luzia; Mast, Fred W.
2012-01-01
Active head turns to the left and right have recently been shown to influence numerical cognition by shifting attention along the mental number line. In the present study, we found that passive whole-body motion influences numerical cognition. In a random-number generation task (Experiment 1), leftward and downward displacement of participants…
Kilic, Ayhan; Cepni, Kamil Serdar; Aybar, Ahmet; Polat, Halil; May, Cuneyt; Parmaksizoglu, Atilla Sancar
2013-12-01
The aim was to evaluate the results of two different methods in surgical treatment for patients with late-stage avascular necrosis of the metatarsal head. Between 2007 and 2012, fourteen consecutive patients (13 females, 1 male; mean age 29 yrs; range, 12-58 yrs) with metatarsal head infarction were enrolled for this study. The main presenting symptom was pain on walking or daily activities. According to the Smillie classification all of lesions were classified as in stage IV-V. Six patients had cheilectomy and microfracture procedure in Group A, 8 patients had received cheilectomy and dorsal crescentic osteotomy in Group B. Clinical outcomes were evaluated according to American Orthopaedic Foot and Ankle Society (AOFAS) lesser toe metatarsophalangeal-interphalangeal scale and range of motion (ROM) of metatarsophalangeal (MTP) joint. Metatarsal shortening and osteotomy-site healing were evaluated with AP and oblique view X-rays. The mean follow-up period was 22 months (range, 12-53). The clinical outcomes were excellent in 11(78%) patients and in the 3(22%) patients the results were good. The AOFAS scores increased from a mean of 66.3 points (range, 55-75) preoperatively to 92 points (range, 84-100) at last follow-up in Group A. The mean AOFAS score increased 55.8 points (range, 45-64) to 90.6 points (range, 84-95) in Group B. In the patients that osteotomy have been applied there were no limitation of movement or fixed deformity of the toe. These results suggest that both surgical techniques may provide significant improvement in pain and ROM of the MTP joint. Copyright © 2013 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Real-time Awake Animal Motion Tracking System for SPECT Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goddard Jr, James Samuel; Baba, Justin S; Lee, Seung Joon
Enhancements have been made in the development of a real-time optical pose measurement and tracking system that provides 3D position and orientation data for a single photon emission computed tomography (SPECT) imaging system for awake, unanesthetized, unrestrained small animals. Three optical cameras with infrared (IR) illumination view the head movements of an animal enclosed in a transparent burrow. Markers placed on the head provide landmark points for image segmentation. Strobed IR LED s are synchronized to the cameras and illuminate the markers to prevent motion blur for each set of images. The system using the three cameras automatically segments themore » markers, detects missing data, rejects false reflections, performs trinocular marker correspondence, and calculates the 3D pose of the animal s head. Improvements have been made in methods for segmentation, tracking, and 3D calculation to give higher speed and more accurate measurements during a scan. The optical hardware has been installed within a Siemens MicroCAT II small animal scanner at Johns Hopkins without requiring functional changes to the scanner operation. The system has undergone testing using both phantoms and live mice and has been characterized in terms of speed, accuracy, robustness, and reliability. Experimental data showing these motion tracking results are given.« less
Thermodynamics and kinetics of molecular motors.
Astumian, R Dean
2010-06-02
Molecular motors are first and foremost molecules, governed by the laws of chemistry rather than of mechanics. The dynamical behavior of motors based on chemical principles can be described as a random walk on a network of states. A key insight is that any molecular motor in solution explores all possible motions and configurations at thermodynamic equilibrium. By using input energy and chemical design to prevent motion that is not wanted, what is left behind is the motion that is desired. This review is focused on two-headed motors such as kinesin and Myosin V that move on a polymeric track. By use of microscopic reversibility, it is shown that the ratio between the number of forward steps and the number of backward steps in any sufficiently long time period does not directly depend on the mechanical properties of the linker between the two heads. Instead, this ratio is governed by the relative chemical specificity of the heads in the front-versus-rear position for the fuel, adenosine triphosphate and its products, adenosine diphosphate and inorganic phosphate. These insights have been key factors in the design of biologically inspired synthetic molecular walkers constructed out of DNA or out of small organic molecules. Copyright (c) 2010 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Unobtrusive Monitoring of Neonatal Brain Temperature Using a Zero-Heat-Flux Sensor Matrix.
Atallah, Louis; Bongers, Edwin; Lamichhane, Bishal; Bambang-Oetomo, Sidarto
2016-01-01
The temperature of preterm neonates must be maintained within a narrow window to ensure their survival. Continuously measuring their core temperature provides an optimal means of monitoring their thermoregulation and their response to environmental changes. However, existing methods of measuring core temperature can be very obtrusive, such as rectal probes, or inaccurate/lagging, such as skin temperature sensors and spot-checks using tympanic temperature sensors. This study investigates an unobtrusive method of measuring brain temperature continuously using an embedded zero-heat-flux (ZHF) sensor matrix placed under the head of the neonate. The measured temperature profile is used to segment areas of motion and incorrect positioning, where the neonate's head is not above the sensors. We compare our measurements during low motion/stable periods to esophageal temperatures for 12 preterm neonates, measured for an average of 5 h per neonate. The method we propose shows good correlation with the reference temperature for most of the neonates. The unobtrusive embedding of the matrix in the neonate's environment poses no harm or disturbance to the care work-flow, while measuring core temperature. To address the effect of motion on the ZHF measurements in the current embodiment, we recommend a more ergonomic embedding ensuring the sensors are continuously placed under the neonate's head.
The control of upper body segment speed and velocity during the golf swing.
Horan, Sean A; Kavanagh, Justin J
2012-06-01
Understanding the dynamics of upper body motion during the downswing is an important step in determining the control strategies required for a successful and repeatable golf swing. The purpose of this study was to examine the relationship between head, thorax, and pelvis motion, during the downswing of professional golfers. Three-dimensional data were collected for 14 male professional golfers (age 27 +/- 8 years, golf-playing experience 13.3 +/- 8 years) using an optical motion analysis system. The amplitude and timing of peak speed and peak velocities were calculated for the head, thorax, and pelvis during the downswing. Cross-correlation analysis was used to examine the strength of coupling and phasing between and within segments. The results indicated the thorax segment had the highest peak speeds and peak velocities for the upper body during the downswing. A strong coupling relationship was evident between the thorax and pelvis (average R2 = 0.92 across all directions), while the head and thorax showed a much more variable relationship (average R2 = 0.76 across all directions). The strong coupling between the thorax and pelvis is possibly a method for simplifying the motor control strategy used during the downswing, and a way of ensuring consistent motor patterns.
Vertigo in virtual reality with haptics: case report.
Viirre, Erik; Ellisman, Mark
2003-08-01
A researcher was working with a desktop virtual environment system. The system was displaying vector fields of a cyclonic weather system, and the system incorporated a haptic display of the forces in the cyclonic field. As the subject viewed the rotating cyclone field, they would move a handle "through" the representation of the moving winds and "feel" the forces buffeting the handle as it moved. Stopping after using the system for about 10 min, the user experienced an immediate sensation of postural instability for several minutes. Several hours later, there was the onset of vertigo with head turns. This vertigo lasted several hours and was accompanied with nausea and motion illusions that exacerbated by head movements. Symptoms persisted mildly the next day and were still present the third and fourth day, but by then were only provoked by head movements. There were no accompanying symptoms or history to suggest an inner ear disorder. Physical examination of inner ear and associated neurologic function was normal. No other users of this system have reported similar symptoms. This case suggests that some individuals may be susceptible to the interaction of displays with motion and movement forces and as a result experience motion illusions. Operators of such systems should be aware of this potential and minimize exposure if vertigo occurs.
Age-related changes in perception of movement in driving scenes.
Lacherez, Philippe; Turner, Laura; Lester, Robert; Burns, Zoe; Wood, Joanne M
2014-07-01
Age-related changes in motion sensitivity have been found to relate to reductions in various indices of driving performance and safety. The aim of this study was to investigate the basis of this relationship in terms of determining which aspects of motion perception are most relevant to driving. Participants included 61 regular drivers (age range 22-87 years). Visual performance was measured binocularly. Measures included visual acuity, contrast sensitivity and motion sensitivity assessed using four different approaches: (1) threshold minimum drift rate for a drifting Gabor patch, (2) Dmin from a random dot display, (3) threshold coherence from a random dot display, and (4) threshold drift rate for a second-order (contrast modulated) sinusoidal grating. Participants then completed the Hazard Perception Test (HPT) in which they were required to identify moving hazards in videos of real driving scenes, and also a Direction of Heading task (DOH) in which they identified deviations from normal lane keeping in brief videos of driving filmed from the interior of a vehicle. In bivariate correlation analyses, all motion sensitivity measures significantly declined with age. Motion coherence thresholds, and minimum drift rate threshold for the first-order stimulus (Gabor patch) both significantly predicted HPT performance even after controlling for age, visual acuity and contrast sensitivity. Bootstrap mediation analysis showed that individual differences in DOH accuracy partly explained these relationships, where those individuals with poorer motion sensitivity on the coherence and Gabor tests showed decreased ability to perceive deviations in motion in the driving videos, which related in turn to their ability to detect the moving hazards. The ability to detect subtle movements in the driving environment (as determined by the DOH task) may be an important contributor to effective hazard perception, and is associated with age, and an individuals' performance on tests of motion sensitivity. The locus of the processing deficits appears to lie in first-order, rather than second-order motion pathways. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
Prevention of experimental motion sickness by scopolamine absorbed through the skin
NASA Technical Reports Server (NTRS)
Graybiel, A.; Knepton, J.; Shaw, J.
1976-01-01
A double-blind placebo-controlled study compared the efficacy of the antimotion sickness drug scopolamine when administered by oral or transdermal routes. A secondary purpose was to extend our bioassay involving fixed-dose combinations of the homergic drugs promethazine and ephedrine. After receiving 12 apparently identical drug-placebo treatments, eight normal male students were exposed in a slow rotation room to stressful accelerations generated by their execution of 40 head movements out of the plane of the room's rotation at 1 rpm and at 1-rpm increments until either symptoms were experienced (just short of frank motion sickness) or the 27-rpm ceiling on the test was reached. Efficacy of a drug was defined in terms of the placebo-range and categorized as beneficial, inconsequential, or detrimental. The only detrimental effect was with scopolamine given orally. It is concluded that the advantages of the transdermal scopolamine, which include minimal side effects and prolonged effectiveness, deserve full exploitation.
Hydrodynamic interaction induced spontaneous rotation of coupled active filaments.
Jiang, Huijun; Hou, Zhonghuai
2014-12-14
We investigate the coupled dynamics of active filaments with long range hydrodynamic interactions (HI). Remarkably, we find that filaments can rotate spontaneously under the same conditions in which a single filament alone can only move in translation. Detailed analysis reveals that the emergence of coupled rotation originates from an asymmetric flow field associated with HI which breaks the symmetry of translational motion when filaments approach. The breaking is then further stabilized by HI to form self-sustained coupled rotation. Intensive simulations show that coupled rotation forms easily when one filament tends to collide with the front-half of the other. For head-to-tail approaching, we observe another interesting HI-induced coupled motion, where filaments move together in the form of one following the other. Moreover, the radius of coupled rotation increases exponentially as the rigidity of the filament increases, which suggests that HI are also important for the alignment of rigid-rod-like filaments which has been assumed to be solely a consequence of direct collisions.
Cervical motion testing: methodology and clinical implications.
Prushansky, Tamara; Dvir, Zeevi
2008-09-01
Measurement of cervical motion (CM) is probably the most commonly applied functional outcome measure in assessing the status of patients with cervical pathology. In general terms, CM refers to motion of the head relative to the trunk as well as conjunct motions within the cervical spine. Multiple techniques and instruments have been used for assessing CM. These were associated with a wide variety of parameters relating to accuracy, reproducibility, and validity. Modern measurement systems enable recording, processing, and documentation of CM with a high degree of precision. Cervical motion measures provide substantial information regarding the severity of motion limitation and level of effort in cervically involved patients. They may also be used for following up performance during and after conservative or invasive interventions.
Biomechanical effect of latissimus dorsi tendon transfer for irreparable massive cuff tear.
Oh, Joo Han; Tilan, Justin; Chen, Yu-Jen; Chung, Kyung Chil; McGarry, Michelle H; Lee, Thay Q
2013-02-01
The purpose of this study was to determine the biomechanical effects of latissimus dorsi transfer in a cadaveric model of massive posterosuperior rotator cuff tear. Eight cadaveric shoulders were tested at 0°, 30°, and 60° of abduction in the scapular plane with anatomically based muscle loading. Humeral rotational range of motion and the amount of humeral rotation due to muscle loading were measured. Glenohumeral kinematics and contact characteristics were measured throughout the range of motion. After testing in the intact condition, the supraspinatus and infraspinatus were resected. The cuff tear was then repaired by latissimus dorsi transfer. Two muscle loading conditions were applied after latissimus transfer to simulate increased tension that may occur due to limited muscle excursion. A repeated-measures analysis of variance was used for statistical analysis. The amount of internal rotation due to muscle loading and maximum internal rotation increased with massive cuff tear and was restored with latissimus transfer (P < .05). At maximum internal rotation, the humeral head apex shifted anteriorly, superiorly, and laterally at 0° of abduction after massive cuff tear (P < .05); this abnormal shift was corrected with latissimus transfer (P < .05). However, at 30° and 60° of abduction, latissimus transfer significantly altered kinematics (P < .05) and latissimus transfer with increased muscle loading increased contact pressure, especially at 60° of abduction. Latissimus dorsi transfer is beneficial in restoring humeral internal/external rotational range of motion, the internal/external rotational balance of the humerus, and glenohumeral kinematics at 0° of abduction. However, latissimus dorsi transfer with simulated limited excursion may lead to an overcompensation that can further deteriorate normal biomechanics, especially at higher abduction angles. Published by Mosby, Inc.
Walk this way: approaching bodies can influence the processing of faces.
Pilz, Karin S; Vuong, Quoc C; Bülthoff, Heinrich H; Thornton, Ian M
2011-01-01
A highly familiar type of movement occurs whenever a person walks towards you. In the present study, we investigated whether this type of motion has an effect on face processing. We took a range of different 3D head models and placed them on a single, identical 3D body model. The resulting figures were animated to approach the observer. In a first series of experiments, we used a sequential matching task to investigate how the motion of an approaching person affects immediate responses to faces. We compared observers' responses following approach sequences to their performance with figures walking backwards (receding motion) or remaining still. Observers were significantly faster in responding to a target face that followed an approach sequence, compared to both receding and static primes. In a second series of experiments, we investigated long-term effects of motion using a delayed visual search paradigm. After studying moving or static avatars, observers searched for target faces in static arrays of varying set sizes. Again, observers were faster at responding to faces that had been learned in the context of an approach sequence. Together these results suggest that the context of a moving body influences face processing, and support the hypothesis that our visual system has mechanisms that aid the encoding of behaviourally-relevant and familiar dynamic events. Copyright © 2010 Elsevier B.V. All rights reserved.