Sample records for head scatter factor

  1. Linac head scatter factor for asymmetric radiation field

    NASA Astrophysics Data System (ADS)

    Soubra, Mazen Ahmed

    1997-11-01

    The head scatter factor, Sh is an important dosimetric quantity used in radiation therapy dose calculation. It is empirically determined and its field size dependence reflects changes in photon scatter from components in the linac treatment head. In this work a detailed study of the physical factors influencing the determination of Sh was performed with particular attention given to asymmetric field geometries. Ionization measurements for 6 and 18 MV photon beams were made to examine the factors which determine Sh. These include: phantom size and material, collimator backscatter, non-lateral electronic equilibrium (LEE) conditions, electron contamination, collimator-exchange, photon energy, flattening filter and off-axis distance (OAD). Results indicated that LEE is not required for Sh measurements if electron contamination is minimized. Brass caps or polystyrene miniphantoms can both be used in Sh measurements provided the phantom thickness is large enough to stop contaminant electrons. Backscatter radiation effects into the monitor chamber were found to be negligible for the Siemens linac. It was found that the presence and shape of the flattening filter had a significant effect on the empirically determined value of Sh was also shown to be a function of OAD, particularly for small fields. For fields larger than 12×12 cm2/ Sh was independent of OAD. A flattening filter mass model was introduced to explain qualitatively the above results. A detailed Monte Carlo simulation of the Siemens KD2 linac head in 6 MV mode was performed to investigate the sources of head scatter which contribute to the measured Sh. The simulated head components include the flattening filter, the electron beam stopper, the primary collimator, the photon monitor chamber and the secondary collimators. The simulations showed that the scatter from the head of the Siemens linac is a complex function of the head components. On the central axis the flattening filter played the dominant role in the contributing to scatter. However this role was significantly reduced off- axis and other head components, such as the electron beam stopper and the primary collimator, became more important. The role of the mirror and ion chamber was relatively minor. Scatter from the secondary collimators was shown to be a function of the filed size and the position of the collimators in the treatment head. They were also found to play a dual role, both as a scatter source and as an attenuator for scatter produced upstream in the linac head. A closed form model, based on the work of Yu and Slobada, was developed to estimate head scatter factors for on- and off-axis asymmetric fields. The model requires three parameters to fit the measured data. The first, a constant c, has a physical significance and is independent of energy and off-axis distance. The second, g, shows a small variation with the energy and OAD while the third parameter, the primary-to-scatter ratio, is strongly dependent on energy and off-axis distance. Comparison of Sh, predicted by the model, to measurement for a large range of symmetric and asymmetric fields showed excellent agreement. A maximum of 0.7% discrepancy was observed at 12 cm OAD.

  2. An investigation of accelerator head scatter and output factor in air.

    PubMed

    Ding, George X

    2004-09-01

    Our purpose in this study was to investigate whether the Monte Carlo simulation can accurately predict output factors in air. Secondary goals were to study the head scatter components and investigate the collimator exchange effect. The Monte Carlo code, BEAMnrc, was used in the study. Photon beams of 6 and 18 MV were from a Varian Clinac 2100EX accelerator and the measurements were performed using an ionization chamber in a mini-phantom. The Monte Carlo calculated in air output factors was within 1% of measured values. The simulation provided information of the origin and the magnitude of the collimator exchange effect. It was shown that the collimator backscatter to the beam monitor chamber played a significant role in the beam output factors. However the magnitude of the scattered dose contributions from the collimator at the isocenter is negligible. The maximum scattered dose contribution from the collimators was about 0.15% and 0.4% of the total dose at the isocenter for a 6 and 18 MV beam, respectively. The scattered dose contributions from the flattening filter at the isocenter were about 0.9-3% and 0.2-6% of the total dose for field sizes of 4x4 cm2-40x40 cm2 for the 6 and 18 MV beam, respectively. The study suggests that measurements of head scatter factors be done at large depth well beyond the depth of electron contamination. The insight information may have some implications for developing generalized empirical models to calculate the head scatter.

  3. SU-F-T-425: Head-Scatter Off-Axis for FFF Megavoltage Photon Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, T; Penjweini, R; Dimofte, A

    Purpose: Head-scatter photons inside a clinical accelerator cause the output to change with collimator setting. On the central-axis, this contribution is well-described by output factor in air (or head-scatter factor). However, a few studies have examined this component at off-axis points. Methods: We define the head-scatter off-axis ratio, HOA, as the ratio of the water kerma in air due to head-scatter photons at the off-axis position x to the water kerma from direct primary photons on the central axis: HOA(cx,cy,xy) = (Q(cx,cy,x) – QP(cx,cy,x))/QP(cx,cy,0), where Q(cx, cy,x), QP(cx,cy,x) are charges measured by an ionization chamber in a miniphantom for collimatormore » setting cx × cy and cx × 3 cm, respectively, at off-axis point x. “Direct primary” is those photons that come from the source without interactions in the intervening structures. Results: We measured HOA for two energies (6XFFF and 6X) along X and Y jaw directions for various collimator settings. The shape of HOA has well defined penumbra for collimator setting larger than 10 × 10 cm2. Conclusion: The narrow gaussian component is interpreted as the source of photons scattered in the flattening filter and the primary collimator. The broad component is attributed to photons scattered in the secondary (variable) collimators. By a direct comparison between 6X and 6XFFF beams, we can confirm that the second component is indeed coming from collimator jaws and identify the parts coming from the primary collimator and the flattening filter, respectively.« less

  4. SU-F-T-66: Characteristics of Electron Beams From Varian Trubeam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dimofte, A; Kennedy, C; Zhu, T

    2016-06-15

    Purpose: The purpose of this study was to compare the electron beam data between Truebeam and 2300ix Varian accelerators for percent depth dose for broad beam and small circular cutouts, cone factors, head scatter factor as a function of cone size and SSD, phantom scatter factor, blocking factor, distance factor and virtual source position. Methods: Measurements were performed for Truebeam and 2300ix Varian accelerators. The main energies used were: 6, 9, 12, 16 and 20 MeV. PDD was measured at SSD = 100 cm for open beam and small circular cutouts (r = 0.5, 1.0, 1.5, 2.0, 3.0, 4.0 andmore » 6.6cm) for different energies. Measurements to determine the head scatter factor (H) were done as a function of radius for six representative energies and five cone sizes (6, 10, 15, 20 and 25cm2). The phantom scatter factor (PSF) is defined as the ratio of blocking factor in water at reference depth and head scatter factor in air. PSF was measured as a function of radius and electron energy. Distance factor was measured for all energies and cones for three SSD’s (100, 110 and 120cm). Results: The percent depth dose (PDD) was measured for small cutouts of radius r = 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 and 5.6cm. Blocking factor (BF) was measured for Truebeam and 2300ix accelerators, for different circular cutouts and energies for a 10×10 cone. Cone factors were compared between the two accelerators for different energies and applicator sizes. Conclusion: Cone factors measured for the two accelerator types differ by up to 5% for the largest applicator size. Blocking factors differs by up to 3%, with the largest variation for the smallest field size (0.5cm). Distance factor for different SSD’s differ by up to 4.5%.« less

  5. Comparison of Head Scatter Factor for 6MV and 10MV flattened (FB) and Unflattened (FFF) Photon Beam using indigenously Designed Columnar Mini Phantom.

    PubMed

    Ashokkumar, Sigamani; Nambi Raj, N Arunai; Sinha, Sujit Nath; Yadav, Girigesh; Thiyagarajan, Rajesh; Raman, Kothanda; Mishra, Manindra Bhushan

    2014-07-01

    To measure and compare the head scatter factor for flattened (FB) and unflattened (FFF) of 6MV and 10MV photon beam using indigenously designed mini phantom. A columnar mini phantom was designed as recommended by AAPM Task Group 74 with low and high atomic number materials at 10 cm (mini phantom) and at approximately twice the depth of maximum dose water equivalent thickness (brass build-up cap). Scatter in the accelerator (Sc) values of 6MV-FFF photon beams are lesser than that of the 6MV-FB photon beams (0.66-2.8%; Clinac iX, 2300CD) and (0.47-1.74%; True beam) for field sizes ranging from 10 × 10 cm(2) to 40 × 40 cm(2). Sc values of 10MV-FFF photon beams are lesser (0.61-2.19%; True beam) than that of the 10MV-FB photons beams for field sizes ranging from 10 × 10 cm(2) to 40 × 40 cm(2). The SSD had no influence on head scatter for both flattened and unflattened beams and irrespective of head design of the different linear accelerators. The presence of field shaping device influences the Sc values. The collimator exchange effect reveals that the opening of the upper jaw increases Sc irrespective of FB or FFF photon beams and different linear accelerators, and it is less significant in FFF beams. Sc values of 6MV-FB square field were in good agreement with that of AAPM, TG-74 published data for Varian (Clinac iX, 2300CD) accelerator. Our results confirm that the removal of flattening filter decreases in the head scatter factor compared to flattened beam. This could reduce the out-of-field dose in advanced treatment delivery techniques.

  6. Comparison of Head Scatter Factor for 6MV and 10MV flattened (FB) and Unflattened (FFF) Photon Beam using indigenously Designed Columnar Mini Phantom

    PubMed Central

    Ashokkumar, Sigamani; Nambi Raj, N Arunai; Sinha, Sujit Nath; Yadav, Girigesh; Thiyagarajan, Rajesh; Raman, Kothanda; Mishra, Manindra Bhushan

    2014-01-01

    To measure and compare the head scatter factor for flattened (FB) and unflattened (FFF) of 6MV and 10MV photon beam using indigenously designed mini phantom. A columnar mini phantom was designed as recommended by AAPM Task Group 74 with low and high atomic number materials at 10 cm (mini phantom) and at approximately twice the depth of maximum dose water equivalent thickness (brass build-up cap). Scatter in the accelerator (Sc) values of 6MV-FFF photon beams are lesser than that of the 6MV-FB photon beams (0.66-2.8%; Clinac iX, 2300CD) and (0.47-1.74%; True beam) for field sizes ranging from 10 × 10 cm2 to 40 × 40 cm2. Sc values of 10MV-FFF photon beams are lesser (0.61-2.19%; True beam) than that of the 10MV-FB photons beams for field sizes ranging from 10 × 10 cm2 to 40 × 40 cm2. The SSD had no influence on head scatter for both flattened and unflattened beams and irrespective of head design of the different linear accelerators. The presence of field shaping device influences the Sc values. The collimator exchange effect reveals that the opening of the upper jaw increases Sc irrespective of FB or FFF photon beams and different linear accelerators, and it is less significant in FFF beams. Sc values of 6MV-FB square field were in good agreement with that of AAPM, TG-74 published data for Varian (Clinac iX, 2300CD) accelerator. Our results confirm that the removal of flattening filter decreases in the head scatter factor compared to flattened beam. This could reduce the out-of-field dose in advanced treatment delivery techniques. PMID:25190997

  7. Levels of detail analysis of microwave scattering from human head models for brain stroke detection

    PubMed Central

    2017-01-01

    In this paper, we have presented a microwave scattering analysis from multiple human head models. This study incorporates different levels of detail in the human head models and its effect on microwave scattering phenomenon. Two levels of detail are taken into account; (i) Simplified ellipse shaped head model (ii) Anatomically realistic head model, implemented using 2-D geometry. In addition, heterogenic and frequency-dispersive behavior of the brain tissues has also been incorporated in our head models. It is identified during this study that the microwave scattering phenomenon changes significantly once the complexity of head model is increased by incorporating more details using magnetic resonance imaging database. It is also found out that the microwave scattering results match in both types of head model (i.e., geometrically simple and anatomically realistic), once the measurements are made in the structurally simplified regions. However, the results diverge considerably in the complex areas of brain due to the arbitrary shape interface of tissue layers in the anatomically realistic head model. After incorporating various levels of detail, the solution of subject microwave scattering problem and the measurement of transmitted and backscattered signals were obtained using finite element method. Mesh convergence analysis was also performed to achieve error free results with a minimum number of mesh elements and a lesser degree of freedom in the fast computational time. The results were promising and the E-Field values converged for both simple and complex geometrical models. However, the E-Field difference between both types of head model at the same reference point differentiated a lot in terms of magnitude. At complex location, a high difference value of 0.04236 V/m was measured compared to the simple location, where it turned out to be 0.00197 V/m. This study also contributes to provide a comparison analysis between the direct and iterative solvers so as to find out the solution of subject microwave scattering problem in a minimum computational time along with memory resources requirement. It is seen from this study that the microwave imaging may effectively be utilized for the detection, localization and differentiation of different types of brain stroke. The simulation results verified that the microwave imaging can be efficiently exploited to study the significant contrast between electric field values of the normal and abnormal brain tissues for the investigation of brain anomalies. In the end, a specific absorption rate analysis was carried out to compare the ionizing effects of microwave signals to different types of head model using a factor of safety for brain tissues. It is also suggested after careful study of various inversion methods in practice for microwave head imaging, that the contrast source inversion method may be more suitable and computationally efficient for such problems. PMID:29177115

  8. Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions

    PubMed Central

    Sisniega, A.; Zbijewski, W.; Badal, A.; Kyprianou, I. S.; Stayman, J. W.; Vaquero, J. J.; Siewerdsen, J. H.

    2013-01-01

    Purpose: The proliferation of cone-beam CT (CBCT) has created interest in performance optimization, with x-ray scatter identified among the main limitations to image quality. CBCT often contends with elevated scatter, but the wide variety of imaging geometry in different CBCT configurations suggests that not all configurations are affected to the same extent. Graphics processing unit (GPU) accelerated Monte Carlo (MC) simulations are employed over a range of imaging geometries to elucidate the factors governing scatter characteristics, efficacy of antiscatter grids, guide system design, and augment development of scatter correction. Methods: A MC x-ray simulator implemented on GPU was accelerated by inclusion of variance reduction techniques (interaction splitting, forced scattering, and forced detection) and extended to include x-ray spectra and analytical models of antiscatter grids and flat-panel detectors. The simulator was applied to small animal (SA), musculoskeletal (MSK) extremity, otolaryngology (Head), breast, interventional C-arm, and on-board (kilovoltage) linear accelerator (Linac) imaging, with an axis-to-detector distance (ADD) of 5, 12, 22, 32, 60, and 50 cm, respectively. Each configuration was modeled with and without an antiscatter grid and with (i) an elliptical cylinder varying 70–280 mm in major axis; and (ii) digital murine and anthropomorphic models. The effects of scatter were evaluated in terms of the angular distribution of scatter incident upon the detector, scatter-to-primary ratio (SPR), artifact magnitude, contrast, contrast-to-noise ratio (CNR), and visual assessment. Results: Variance reduction yielded improvements in MC simulation efficiency ranging from ∼17-fold (for SA CBCT) to ∼35-fold (for Head and C-arm), with the most significant acceleration due to interaction splitting (∼6 to ∼10-fold increase in efficiency). The benefit of a more extended geometry was evident by virtue of a larger air gap—e.g., for a 16 cm diameter object, the SPR reduced from 1.5 for ADD = 12 cm (MSK geometry) to 1.1 for ADD = 22 cm (Head) and to 0.5 for ADD = 60 cm (C-arm). Grid efficiency was higher for configurations with shorter air gap due to a broader angular distribution of scattered photons—e.g., scatter rejection factor ∼0.8 for MSK geometry versus ∼0.65 for C-arm. Grids reduced cupping for all configurations but had limited improvement on scatter-induced streaks and resulted in a loss of CNR for the SA, Breast, and C-arm. Relative contribution of forward-directed scatter increased with a grid (e.g., Rayleigh scatter fraction increasing from ∼0.15 without a grid to ∼0.25 with a grid for the MSK configuration), resulting in scatter distributions with greater spatial variation (the form of which depended on grid orientation). Conclusions: A fast MC simulator combining GPU acceleration with variance reduction provided a systematic examination of a range of CBCT configurations in relation to scatter, highlighting the magnitude and spatial uniformity of individual scatter components, illustrating tradeoffs in CNR and artifacts and identifying the system geometries for which grids are more beneficial (e.g., MSK) from those in which an extended geometry is the better defense (e.g., C-arm head imaging). Compact geometries with an antiscatter grid challenge assumptions of slowly varying scatter distributions due to increased contribution of Rayleigh scatter. PMID:23635285

  9. Monte Carlo study of neutron-ambient dose equivalent to patient in treatment room.

    PubMed

    Mohammadi, A; Afarideh, H; Abbasi Davani, F; Ghergherehchi, M; Arbabi, A

    2016-12-01

    This paper presents an analytical method for the calculation of the neutron ambient dose equivalent H* (10) regarding patients, whereby the different concrete types that are used in the surrounding walls of the treatment room are considered. This work has been performed according to a detailed simulation of the Varian 2300C/D linear accelerator head that is operated at 18MV, and silver activation counter as a neutron detector, for which the Monte Carlo MCNPX 2.6 code is used, with and without the treatment room walls. The results show that, when compared to the neutrons that leak from the LINAC, both the scattered and thermal neutrons are the major factors that comprise the out-of field neutron dose. The scattering factors for the limonite-steel, magnetite-steel, and ordinary concretes have been calculated as 0.91±0.09, 1.08±0.10, and 0.371±0.01, respectively, while the corresponding thermal factors are 34.22±3.84, 23.44±1.62, and 52.28±1.99, respectively (both the scattering and thermal factors are for the isocenter region); moreover, the treatment room is composed of magnetite-steel and limonite-steel concretes, so the neutron doses to the patient are 1.79 times and 1.62 times greater than that from an ordinary concrete composition. The results also confirm that the scattering and thermal factors do not depend on the details of the chosen linear accelerator head model. It is anticipated that the results of the present work will be of great interest to the manufacturers of medical linear accelerators. Copyright © 2016. Published by Elsevier Ltd.

  10. Modeling of a multileaf collimator

    NASA Astrophysics Data System (ADS)

    Kim, Siyong

    A comprehensive physics model of a multileaf collimator (MLC) field for treatment planning was developed. Specifically, an MLC user interface module that includes a geometric optimization tool and a general method of in- air output factor calculation were developed. An automatic tool for optimization of MLC conformation is needed to realize the potential benefits of MLC. It is also necessary that a radiation therapy treatment planning (RTTP) system is capable of modeling MLC completely. An MLC geometric optimization and user interface module was developed. The planning time has been reduced significantly by incorporating the MLC module into the main RTTP system, Radiation Oncology Computer System (ROCS). The dosimetric parameter that has the most profound effect on the accuracy of the dose delivered with an MLC is the change in the in-air output factor that occurs with field shaping. It has been reported that the conventional method of calculating an in-air output factor cannot be used for MLC shaped fields accurately. Therefore, it is necessary to develop algorithms that allow accurate calculation of the in-air output factor. A generalized solution for an in-air output factor calculation was developed. Three major contributors of scatter to the in-air output-flattening filter, wedge, and tertiary collimator-were considered separately. By virtue of a field mapping method, in which a source plane field determined by detector's eye view is mapped into a detector plane field, no additional dosimetric data acquisition other than the standard data set for a range of square fields is required for the calculation of head scatter. Comparisons of in-air output factors between calculated and measured values show a good agreement for both open and wedge fields. For rectangular fields, a simple equivalent square formula was derived based on the configuration of a linear accelerator treatment head. This method predicts in-air output to within 1% accuracy. A two-effective-source algorithm was developed to account for the effect of source to detector distance on in-air output for wedge fields. Two effective sources, one for head scatter and the other for wedge scatter, were dealt with independently. Calculations provided less than 1% difference of in-air output factors from measurements. This approach offers the best comprehensive accuracy in radiation delivery with field shapes defined using MLC. This generalized model works equally well with fields shaped by any type of tertiary collimator and have the necessary framework to extend its application to intensity modulated radiation therapy.

  11. Meteoroid head echo polarization features studied by numerical electromagnetics modeling

    NASA Astrophysics Data System (ADS)

    Vertatschitsch, L. E.; Sahr, J. D.; Colestock, P.; Close, S.

    2011-12-01

    Meteoroid head echoes are radar returns associated with scatter from the dense plasma surrounding meteoroids striking the Earth's atmosphere. Such echoes are detected by high power, large aperture (HPLA) radars. Frequently such detections show large variations in signal strength that suggest constructive and destructive interference. Using the ARPA Long-Range Tracking and Instrumentation Radar (ALTAIR) we can also observe the polarization of the returns. Usually, scatter from head echoes resembles scatter from a small sphere; when transmitting right circular polarization (RC), the received signal consists entirely of left circular polarization (LC). For some detections, power is also received in the RC channel, which indicates the presence of a more complicated scattering process. Radar returns of a fragmenting meteoroid are simulated using a hard-sphere scattering model numerically evaluated in the resonant region of Mie scatter. The cross- and co-polar scattering cross-sections are computed for pairs of spheres lying within a few wavelengths, simulating the earliest stages of fragmentation upon atmospheric impact. The likelihood of detecting this sort of idealized fragmentation event is small, but this demonstrates the measurements that would result from such an event would display RC power comparable to LC power, matching the anomalous data. The resulting computations show that fragmentation is a consistent interpretation for these head echo radar returns.

  12. Practical and adequate approach to modeling light propagation in an adult head with low-scattering regions by use of diffusion theory.

    PubMed

    Koyama, Tatsuya; Iwasaki, Atsushi; Ogoshi, Yosuke; Okada, Eiji

    2005-04-10

    A practical and adequate approach to modeling light propagation in an adult head with a low-scattering cerebrospinal fluid (CSF) region by use of diffusion theory was investigated. The diffusion approximation does not hold in a nonscattering or low-scattering regions. The hybrid radiosity-diffusion method was adopted to model the light propagation in the head with a nonscattering region. In the hybrid method the geometry of the nonscattering region is acquired as a priori information. In reality, low-level scattering occurs in the CSF region and may reduce the error caused by the diffusion approximation. The partial optical path length and the spatial sensitivity profile calculated by the finite-element method agree well with those calculated by the Monte Carlo method in the case in which the transport scattering coefficient of the CSF layer is greater than 0.3 mm(-1). Because it is feasible to assume that the transport scattering coefficient of a CSF layer is 0.3 mm(-1), it is practical to adopt diffusion theory to the modeling of light propagation in an adult head as an alternative to the hybrid method.

  13. Practical and adequate approach to modeling light propagation in an adult head with low-scattering regions by use of diffusion theory

    NASA Astrophysics Data System (ADS)

    Koyama, Tatsuya; Iwasaki, Atsushi; Ogoshi, Yosuke; Okada, Eiji

    2005-04-01

    A practical and adequate approach to modeling light propagation in an adult head with a low-scattering cerebrospinal fluid (CSF) region by use of diffusion theory was investigated. The diffusion approximation does not hold in a nonscattering or low-scattering regions. The hybrid radiosity-diffusion method was adopted to model the light propagation in the head with a nonscattering region. In the hybrid method the geometry of the nonscattering region is acquired as a priori information. In reality, low-level scattering occurs in the CSF region and may reduce the error caused by the diffusion approximation. The partial optical path length and the spatial sensitivity profile calculated by the finite-element method agree well with those calculated by the Monte Carlo method in the case in which the transport scattering coefficient of the CSF layer is greater than 0.3 mm^-1. Because it is feasible to assume that the transport scattering coefficient of a CSF layer is 0.3 mm^-1, it is practical to adopt diffusion theory to the modeling of light propagation in an adult head as an alternative to the hybrid method.

  14. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Islam, N; Xiong, Z; Vijayan, S

    2015-06-15

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with anmore » air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant.« less

  15. Hybrid Monte Carlo-Diffusion Method For Light Propagation in Tissue With a Low-Scattering Region

    NASA Astrophysics Data System (ADS)

    Hayashi, Toshiyuki; Kashio, Yoshihiko; Okada, Eiji

    2003-06-01

    The heterogeneity of the tissues in a head, especially the low-scattering cerebrospinal fluid (CSF) layer surrounding the brain has previously been shown to strongly affect light propagation in the brain. The radiosity-diffusion method, in which the light propagation in the CSF layer is assumed to obey the radiosity theory, has been employed to predict the light propagation in head models. Although the CSF layer is assumed to be a nonscattering region in the radiosity-diffusion method, fine arachnoid trabeculae cause faint scattering in the CSF layer in real heads. A novel approach, the hybrid Monte Carlo-diffusion method, is proposed to calculate the head models, including the low-scattering region in which the light propagation does not obey neither the diffusion approximation nor the radiosity theory. The light propagation in the high-scattering region is calculated by means of the diffusion approximation solved by the finite-element method and that in the low-scattering region is predicted by the Monte Carlo method. The intensity and mean time of flight of the detected light for the head model with a low-scattering CSF layer calculated by the hybrid method agreed well with those by the Monte Carlo method, whereas the results calculated by means of the diffusion approximation included considerable error caused by the effect of the CSF layer. In the hybrid method, the time-consuming Monte Carlo calculation is employed only for the thin CSF layer, and hence, the computation time of the hybrid method is dramatically shorter than that of the Monte Carlo method.

  16. Hybrid Monte Carlo-diffusion method for light propagation in tissue with a low-scattering region.

    PubMed

    Hayashi, Toshiyuki; Kashio, Yoshihiko; Okada, Eiji

    2003-06-01

    The heterogeneity of the tissues in a head, especially the low-scattering cerebrospinal fluid (CSF) layer surrounding the brain has previously been shown to strongly affect light propagation in the brain. The radiosity-diffusion method, in which the light propagation in the CSF layer is assumed to obey the radiosity theory, has been employed to predict the light propagation in head models. Although the CSF layer is assumed to be a nonscattering region in the radiosity-diffusion method, fine arachnoid trabeculae cause faint scattering in the CSF layer in real heads. A novel approach, the hybrid Monte Carlo-diffusion method, is proposed to calculate the head models, including the low-scattering region in which the light propagation does not obey neither the diffusion approximation nor the radiosity theory. The light propagation in the high-scattering region is calculated by means of the diffusion approximation solved by the finite-element method and that in the low-scattering region is predicted by the Monte Carlo method. The intensity and mean time of flight of the detected light for the head model with a low-scattering CSF layer calculated by the hybrid method agreed well with those by the Monte Carlo method, whereas the results calculated by means of the diffusion approximation included considerable error caused by the effect of the CSF layer. In the hybrid method, the time-consuming Monte Carlo calculation is employed only for the thin CSF layer, and hence, the computation time of the hybrid method is dramatically shorter than that of the Monte Carlo method.

  17. Plasma diagnostics of non-equilibrium atmospheric plasma jets

    NASA Astrophysics Data System (ADS)

    Shashurin, Alexey; Scott, David; Keidar, Michael; Shneider, Mikhail

    2014-10-01

    Intensive development and biomedical application of non-equilibrium atmospheric plasma jet (NEAPJ) facilitates rapid growth of the plasma medicine field. The NEAPJ facility utilized at the George Washington University (GWU) demonstrated efficacy for treatment of various cancer types (lung, bladder, breast, head, neck, brain and skin). In this work we review recent advances of the research conducted at GWU concerned with the development of NEAPJ diagnostics including Rayleigh Microwave Scattering setup, method of streamer scattering on DC potential, Rogowski coils, ICCD camera and optical emission spectroscopy. These tools allow conducting temporally-resolved measurements of plasma density, electrical potential, charge and size of the streamer head, electrical currents flowing though the jet, ionization front propagation speed etc. Transient dynamics of plasma and discharge parameters will be considered and physical processes involved in the discharge will be analyzed including streamer breakdown, electrical coupling of the streamer tip with discharge electrodes, factors determining NEAPJ length, cross-sectional shape and propagation path etc.

  18. Neutron production in the interaction of 12 and 18 MeV electrons with a scattering foil inside a simple LINAC head.

    PubMed

    Soto-Bernal, Tzinnia Gabriela; Baltazar-Raigosa, Antonio; Medina-Castro, Diego; Vega-Carrillo, Hector Rene

    2018-04-18

    The characteristics of photons and neutrons produced during the interaction between a monoenergetic (12 and 18 MeV) electron beam and a tungsten scattering foil enclosed into a 10 cm-thick tungsten shell have been determined using Monte Carlo methods. This model was used aiming to represent a linac head working in electron-mode for cancer treatment. Photon and neutron spectra were determined around the scattering foil and to 50 and 100 cm below the electron source. Induced photons are mainly produced along the direction of the incoming electron beam. On the other hand, neutrons are produced in two sites, mainly in the inner surface of the linac head and in less extent in the scattering foil. The neutron spectra are evaporation neutrons which are emitted isotropically from the site where are produced leaking out from the linac head, reaching locations were the patient is allocated. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Improved scatter correction with factor analysis for planar and SPECT imaging

    NASA Astrophysics Data System (ADS)

    Knoll, Peter; Rahmim, Arman; Gültekin, Selma; Šámal, Martin; Ljungberg, Michael; Mirzaei, Siroos; Segars, Paul; Szczupak, Boguslaw

    2017-09-01

    Quantitative nuclear medicine imaging is an increasingly important frontier. In order to achieve quantitative imaging, various interactions of photons with matter have to be modeled and compensated. Although correction for photon attenuation has been addressed by including x-ray CT scans (accurate), correction for Compton scatter remains an open issue. The inclusion of scattered photons within the energy window used for planar or SPECT data acquisition decreases the contrast of the image. While a number of methods for scatter correction have been proposed in the past, in this work, we propose and assess a novel, user-independent framework applying factor analysis (FA). Extensive Monte Carlo simulations for planar and tomographic imaging were performed using the SIMIND software. Furthermore, planar acquisition of two Petri dishes filled with 99mTc solutions and a Jaszczak phantom study (Data Spectrum Corporation, Durham, NC, USA) using a dual head gamma camera were performed. In order to use FA for scatter correction, we subdivided the applied energy window into a number of sub-windows, serving as input data. FA results in two factor images (photo-peak, scatter) and two corresponding factor curves (energy spectra). Planar and tomographic Jaszczak phantom gamma camera measurements were recorded. The tomographic data (simulations and measurements) were processed for each angular position resulting in a photo-peak and a scatter data set. The reconstructed transaxial slices of the Jaszczak phantom were quantified using an ImageJ plugin. The data obtained by FA showed good agreement with the energy spectra, photo-peak, and scatter images obtained in all Monte Carlo simulated data sets. For comparison, the standard dual-energy window (DEW) approach was additionally applied for scatter correction. FA in comparison with the DEW method results in significant improvements in image accuracy for both planar and tomographic data sets. FA can be used as a user-independent approach for scatter correction in nuclear medicine.

  20. General equation for the differential pathlength factor of the frontal human head depending on wavelength and age.

    PubMed

    Scholkmann, Felix; Wolf, Martin

    2013-10-01

    Continuous-wave near-infrared spectroscopy and near-infrared imaging enable the measurement of relative concentration changes in oxy- and deoxyhemoglobin and thus hemodynamics and oxygenation. The accuracy of determined changes depends mainly on the modeling of the light transport through the probed tissue. Due to the highly scattering nature of tissue, the light path is longer than the source-detector separation (d). This is incorporated in modeling by multiplying d by a differential pathlength factor (DPF) which depends on several factors such as wavelength, age of the subject, and type of tissue. In the present work, we derive a general DPF equation for the frontal human head, incorporating dependency on wavelength and age, based on published data. We validated the equation using different data sets of experimentally determined DPFs from six independent studies.

  1. Low-resolution mapping of the effective attenuation coefficient of the human head: a multidistance approach applied to high-density optical recordings

    PubMed Central

    Chiarelli, Antonio M.; Maclin, Edward L.; Low, Kathy A.; Fantini, Sergio; Fabiani, Monica; Gratton, Gabriele

    2017-01-01

    Abstract. Near infrared (NIR) light has been widely used for measuring changes in hemoglobin concentration in the human brain (functional NIR spectroscopy, fNIRS). fNIRS is based on the differential measurement and estimation of absorption perturbations, which, in turn, are based on correctly estimating the absolute parameters of light propagation. To do so, it is essential to accurately characterize the baseline optical properties of tissue (absorption and reduced scattering coefficients). However, because of the diffusive properties of the medium, separate determination of absorption and scattering across the head is challenging. The effective attenuation coefficient (EAC), which is proportional to the geometric mean of absorption and reduced scattering coefficients, can be estimated in a simpler fashion by multidistance light decay measurements. EAC mapping could be of interest for the scientific community because of its absolute information content, and because light propagation is governed by the EAC for source–detector distances exceeding 1 cm, which sense depths extending beyond the scalp and skull layers. Here, we report an EAC mapping procedure that can be applied to standard fNIRS recordings, yielding topographic maps with 2- to 3-cm resolution. Application to human data indicates the importance of venous sinuses in determining regional EAC variations, a factor often overlooked. PMID:28466026

  2. Low-resolution mapping of the effective attenuation coefficient of the human head: a multidistance approach applied to high-density optical recordings.

    PubMed

    Chiarelli, Antonio M; Maclin, Edward L; Low, Kathy A; Fantini, Sergio; Fabiani, Monica; Gratton, Gabriele

    2017-04-01

    Near infrared (NIR) light has been widely used for measuring changes in hemoglobin concentration in the human brain (functional NIR spectroscopy, fNIRS). fNIRS is based on the differential measurement and estimation of absorption perturbations, which, in turn, are based on correctly estimating the absolute parameters of light propagation. To do so, it is essential to accurately characterize the baseline optical properties of tissue (absorption and reduced scattering coefficients). However, because of the diffusive properties of the medium, separate determination of absorption and scattering across the head is challenging. The effective attenuation coefficient (EAC), which is proportional to the geometric mean of absorption and reduced scattering coefficients, can be estimated in a simpler fashion by multidistance light decay measurements. EAC mapping could be of interest for the scientific community because of its absolute information content, and because light propagation is governed by the EAC for source-detector distances exceeding 1 cm, which sense depths extending beyond the scalp and skull layers. Here, we report an EAC mapping procedure that can be applied to standard fNIRS recordings, yielding topographic maps with 2- to 3-cm resolution. Application to human data indicates the importance of venous sinuses in determining regional EAC variations, a factor often overlooked.

  3. Methods and apparatus for transparent display using scattering nanoparticles

    DOEpatents

    Hsu, Chia Wei; Qiu, Wenjun; Zhen, Bo; Shapira, Ofer; Soljacic, Marin

    2017-06-14

    Transparent displays enable many useful applications, including heads-up displays for cars and aircraft as well as displays on eyeglasses and glass windows. Unfortunately, transparent displays made of organic light-emitting diodes are typically expensive and opaque. Heads-up displays often require fixed light sources and have limited viewing angles. And transparent displays that use frequency conversion are typically energy inefficient. Conversely, the present transparent displays operate by scattering visible light from resonant nanoparticles with narrowband scattering cross sections and small absorption cross sections. More specifically, projecting an image onto a transparent screen doped with nanoparticles that selectively scatter light at the image wavelength(s) yields an image on the screen visible to an observer. Because the nanoparticles scatter light at only certain wavelengths, the screen is practically transparent under ambient light. Exemplary transparent scattering displays can be simple, inexpensive, scalable to large sizes, viewable over wide angular ranges, energy efficient, and transparent simultaneously.

  4. Methods and apparatus for transparent display using scattering nanoparticles

    DOEpatents

    Hsu, Chia Wei; Qiu, Wenjun; Zhen, Bo; Shapira, Ofer; Soljacic, Marin

    2016-05-10

    Transparent displays enable many useful applications, including heads-up displays for cars and aircraft as well as displays on eyeglasses and glass windows. Unfortunately, transparent displays made of organic light-emitting diodes are typically expensive and opaque. Heads-up displays often require fixed light sources and have limited viewing angles. And transparent displays that use frequency conversion are typically energy inefficient. Conversely, the present transparent displays operate by scattering visible light from resonant nanoparticles with narrowband scattering cross sections and small absorption cross sections. More specifically, projecting an image onto a transparent screen doped with nanoparticles that selectively scatter light at the image wavelength(s) yields an image on the screen visible to an observer. Because the nanoparticles scatter light at only certain wavelengths, the screen is practically transparent under ambient light. Exemplary transparent scattering displays can be simple, inexpensive, scalable to large sizes, viewable over wide angular ranges, energy efficient, and transparent simultaneously.

  5. SU-E-I-22: Dependence On Calibration Phantom and Field Area of the Conversion Factor Used to Calculate Skin Dose During Neuro-Interventional Fluoroscopic Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rana, V K; Vijayan, S; Rudin, S R

    Purpose: To determine the appropriate calibration factor to use when calculating skin dose with our real-time dose-tracking system (DTS) during neuro-interventional fluoroscopic procedures by evaluating the difference in backscatter from different phantoms and as a function of entrance-skin field area. Methods: We developed a dose-tracking system to calculate and graphically display the cumulative skin-dose distribution in real time. To calibrate the DTS for neuro-interventional procedures, a phantom is needed that closely approximates the scattering properties of the head. We compared the x-ray backscatter from eight phantoms: 20-cm-thick solid water, 16-cm diameter water-filled container, 16-cm CTDI phantom, modified-ANSI head phantom, 20-cm-thickmore » PMMA, Kyoto-Kagaku PBU- 50 head, Phantom-Labs SK-150 head, and RSD RS-240T head. The phantoms were placed on the patient table with the entrance surface at 15 cm tube-side from the isocenter of a Toshiba Infinix C-arm, and the entrance-skin exposure was measured with a calibrated 6-cc PTW ionization chamber. The measurement included primary radiation, backscatter from the phantom and forward scatter from the table and pad. The variation in entrance-skin exposure was also measured as a function of the skin-entrance area for a 30x30 cm by 20-cm-thick PMMA phantom and the SK-150 head phantom using four different added beam filters. Results: The entranceskin exposure values measured for eight different phantoms differed by up to 12%, while the ratio of entrance exposure of all phantoms relative to solid water showed less than 3% variation with kVp. The change in entrance-skin exposure with entrance-skin area was found to differ for the SK-150 head compared to the 20-cm PMMA phantom and the variation with field area was dependent on the added beam filtration. Conclusion: To accurately calculate skin dose for neuro-interventional procedures with the DTS, the phantom for calibration should be carefully chosen since different phantoms can contribute different backscatter for identical exposure parameters. Research supported in part by Toshiba Medical Systems and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.« less

  6. TU-F-CAMPUS-T-02: Risk Assessment of Scattered Neutrons for a Fetus From Proton Therapy of a Brain Tumor During Pregnancy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Moteabbed, M

    Purpose: To determine the scattered neutron dose and the resulting risk for a fetus from proton therapy for brain tumors during pregnancy. Methods: Using the Monte Carlo platform TOPAS, the ICRP reference parameters based anthropomorphic pregnancy phantoms for three stages (3-, 6-, 9-month) were applied to evaluate the scattered neutron dose and dose equivalent. To calculate the dose equivalent, organ specific linear energy transfer (LET) based quality factor was used. Treatment plans from both passive scattering (PS) and pencil beam scanning (PBS) methods were considered in this study. Results: For pencil beam scanning, the neutron dose equivalent in the softmore » tissue of the fetus increases from 1.53x10−{sup 3} to 2.84x10−{sup 3} mSv per treatment Gy with increasing stage of gestation. This is due to scattered neutrons from the patient as the main contaminant source in PBS and a decrease in distance between the soft tissue of the fetus and GTV with increasing stage of gestation. For passive scattering, neutron dose equivalent to the soft tissue of the fetus shows a decrease from 0.17 to 0.13 mSv per treatment Gy in different stages, while the dose to the brain shows little difference around 0.18 mSv per treatment Gy because scattered neutrons from the treatment head contribute predominantly in passive scattering. Conclusion: The results show that the neutron dose to the fetus assuming a prescribed dose of 52.2 Gy is negligible for PBS, and is comparable to the scattered dose (0–10 mSv) from a head and neck CT scan for PS. It can be concluded that the dose to fetus is far lower than the thresholds of malformation, SMR and lethal death. The excess relative risk of childhood cancer induction would be increased by 0.48 and 0.103 using the Oxford Survey of Childhood Cancers and Japanese atomic model, respectively. Changran Geng is supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087)« less

  7. Influence of length and conformation of saccharide head groups on the mechanics of glycolipid membranes: Unraveled by off-specular neutron scattering

    NASA Astrophysics Data System (ADS)

    Yamamoto, Akihisa; Abuillan, Wasim; Burk, Alexandra S.; Körner, Alexander; Ries, Annika; Werz, Daniel B.; Demé, Bruno; Tanaka, Motomu

    2015-04-01

    The mechanical properties of multilayer stacks of Gb3 glycolipid that play key roles in metabolic disorders (Fabry disease) were determined quantitatively by using specular and off-specular neutron scattering. Because of the geometry of membrane stacks deposited on planar substrates, the scattered intensity profile was analyzed in a 2D reciprocal space map as a function of in-plane and out-of-plane scattering vector components. The two principal mechanical parameters of the membranes, namely, bending rigidity and compression modulus, can be quantified by full calculation of scattering functions with the aid of an effective cut-off radius that takes the finite sample size into consideration. The bulkier "bent" Gb3 trisaccharide group makes the membrane mechanics distinctly different from cylindrical disaccharide (lactose) head groups and shorter "bent" disaccharide (gentiobiose) head groups. The mechanical characterization of membranes enriched with complex glycolipids has high importance in understanding the mechanisms of diseases such as sphingolipidoses caused by the accumulation of non-degenerated glycosphingolipids in lysosomes or inhibition of protein synthesis triggered by the specific binding of Shiga toxin to Gb3.

  8. Influence of length and conformation of saccharide head groups on the mechanics of glycolipid membranes: Unraveled by off-specular neutron scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Akihisa, E-mail: ayamamoto@icems.kyoto-u.ac.jp, E-mail: tanaka@uni-heidelberg.de; Tanaka, Motomu, E-mail: ayamamoto@icems.kyoto-u.ac.jp, E-mail: tanaka@uni-heidelberg.de; Institute for Integrated Cell-Material Sciences

    2015-04-21

    The mechanical properties of multilayer stacks of Gb3 glycolipid that play key roles in metabolic disorders (Fabry disease) were determined quantitatively by using specular and off-specular neutron scattering. Because of the geometry of membrane stacks deposited on planar substrates, the scattered intensity profile was analyzed in a 2D reciprocal space map as a function of in-plane and out-of-plane scattering vector components. The two principal mechanical parameters of the membranes, namely, bending rigidity and compression modulus, can be quantified by full calculation of scattering functions with the aid of an effective cut-off radius that takes the finite sample size into consideration.more » The bulkier “bent” Gb3 trisaccharide group makes the membrane mechanics distinctly different from cylindrical disaccharide (lactose) head groups and shorter “bent” disaccharide (gentiobiose) head groups. The mechanical characterization of membranes enriched with complex glycolipids has high importance in understanding the mechanisms of diseases such as sphingolipidoses caused by the accumulation of non-degenerated glycosphingolipids in lysosomes or inhibition of protein synthesis triggered by the specific binding of Shiga toxin to Gb3.« less

  9. Interferometric Meteor Head Echo Observations using the Southern Argentina Agile Meteor Radar (SAAMER)

    NASA Technical Reports Server (NTRS)

    Janches, D.; Hocking, W.; Pifko, S.; Hormaechea, J. L.; Fritts, D. C.; Brunini, C; Michell, R.; Samara, M.

    2013-01-01

    A radar meteor echo is the radar scattering signature from the free-electrons in a plasma trail generated by entry of extraterrestrial particles into the atmosphere. Three categories of scattering mechanisms exist: specular, nonspecular trails, and head-echoes. Generally, there are two types of radars utilized to detect meteors. Traditional VHF meteor radars (often called all-sky1radars) primarily detect the specular reflection of meteor trails traveling perpendicular to the line of sight of the scattering trail, while High Power and Large Aperture (HPLA) radars efficiently detect meteor head-echoes and, in some cases, non-specular trails. The fact that head-echo measurements can be performed only with HPLA radars limits these studies in several ways. HPLA radars are very sensitive instruments constraining the studies to the lower masses, and these observations cannot be performed continuously because they take place at national observatories with limited allocated observing time. These drawbacks can be addressed by developing head echo observing techniques with modified all-sky meteor radars. In addition, the fact that the simultaneous detection of all different scattering mechanisms can be made with the same instrument, rather than requiring assorted different classes of radars, can help clarify observed differences between the different methodologies. In this study, we demonstrate that such concurrent observations are now possible, enabled by the enhanced design of the Southern Argentina Agile Meteor Radar (SAAMER) deployed at the Estacion Astronomica Rio Grande (EARG) in Tierra del Fuego, Argentina. The results presented here are derived from observations performed over a period of 12 days in August 2011, and include meteoroid dynamical parameter distributions, radiants and estimated masses. Overall, the SAAMER's head echo detections appear to be produced by larger particles than those which have been studied thus far using this technique.

  10. SU-E-T-517: Investigation of Factors Contributing to Extracranial Radiation Doses From Leksell Gamma Knife

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kon, D; Kameda Medical Centre, Chiba, JP; Nakano, M

    2015-06-15

    Purpose The purpose of this study is to investigate dominant factors for doses to extracranial sites in treatment with Leksell Gamma Knife (LGK). Methods Monte Carlo simulation was implemented using EGS5 version 1.4.401. The simulation was divided into two major steps for the purpose of efficiency. As the first step, phase-space files were obtained at a scoring plane located just below patient-side surface of the collimator helmet of LGK. Scored particles were classified into three groups, primary, leakage and scatter, using their history information until their arrival to the scoring plane. Then classification was used at the following second stepmore » simulation to investigate which type of particle is dominant in the deposited energy at extra-cranial sites. In the second stage, a cylindrical phantom with a semisphere shaped head was modeled such that the geometrical center of the phantom’s head corresponds to the unit center point (UCP) of LGK. Scoring regions were arranged at 10 cm intervals from the UCP to 70 cm away on the central axis of the phantom. Energy deposition from each type of particles and location of interaction were recorded. Results The dominant factor of deposited energy depended on the collimator size. In the case of smaller collimator size, leakage was dominant. However, contribution of leakage was relatively small in the case of larger collimator size. The contribution of internal scatter varied with the distance from the UCP. In the proximal areas, internal scatter was dominant, whereas in the distal areas, particles interacting with machine components became dominant factor. Conclusion The Result of this study indicates that the dominant factor to dose to an extracranial site can vary with the distance from UCP and with collimator size. This means that the variation of this contribution must be considered for modeling of the extracranial dose especially in the distal area. This work was partly supported by the JSPS Core-to-Core Program (No. 23003)« less

  11. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Bosco, G; Darenbourg, B

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measuredmore » at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of the MR-Linac system studied in this work.« less

  12. A method to incorporate leakage and head scatter corrections into a tomotherapy inverse treatment planning algorithm

    NASA Astrophysics Data System (ADS)

    Holmes, Timothy W.

    2001-01-01

    A detailed tomotherapy inverse treatment planning method is described which incorporates leakage and head scatter corrections during each iteration of the optimization process, allowing these effects to be directly accounted for in the optimized dose distribution. It is shown that the conventional inverse planning method for optimizing incident intensity can be extended to include a `concurrent' leaf sequencing operation from which the leakage and head scatter corrections are determined. The method is demonstrated using the steepest-descent optimization technique with constant step size and a least-squared error objective. The method was implemented using the MATLAB scientific programming environment and its feasibility demonstrated for 2D test cases simulating treatment delivery using a single coplanar rotation. The results indicate that this modification does not significantly affect convergence of the intensity optimization method when exposure times of individual leaves are stratified to a large number of levels (>100) during leaf sequencing. In general, the addition of aperture dependent corrections, especially `head scatter', reduces incident fluence in local regions of the modulated fan beam, resulting in increased exposure times for individual collimator leaves. These local variations can result in 5% or greater local variation in the optimized dose distribution compared to the uncorrected case. The overall efficiency of the modified intensity optimization algorithm is comparable to that of the original unmodified case.

  13. Polarized light scattering as a probe for changes in chromosome structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, Daniel Benjamin

    1993-10-01

    Measurements and calculations of polarized light scattering are applied to chromosomes. Calculations of the Mueller matrix, which completely describes how the polarization state of light is altered upon scattering, are developed for helical structures related to that of chromosomes. Measurements of the Mueller matrix are presented for octopus sperm heads, and dinoflagellates. Comparisons of theory and experiment are made. A working theory of polarized light scattering from helices is developed. The use of the first Born approximation vs the coupled dipole approximation are investigated. A comparison of continuous, calculated in this work, and discrete models is also discussed. By comparingmore » light scattering measurements with theoretical predictions the average orientation of DNA in an octopus sperm head is determined. Calculations are made for the Mueller matrix of DNA plectonemic helices at UV, visible and X-ray wavelengths. Finally evidence is presented that the chromosomes of dinoflagellates are responsible for observed differential scattering of circularly-polarized light. This differential scattering is found to vary in a manner that is possibly correlated to the cell cycle of the dinoflagellates. It is concluded that by properly choosing the wavelength probe polarized light scattering can provide a useful tool to study chromosome structure.« less

  14. Towards the estimation of the scattered energy spectra reaching the head of the medical staff during interventional radiology: A Monte Carlo simulation study

    NASA Astrophysics Data System (ADS)

    Zagorska, A.; Bliznakova, K.; Buchakliev, Z.

    2015-09-01

    In 2012, the International Commission on Radiological Protection has recommended a reduction of the dose limits to the eye lens for occupational exposure. Recent studies showed that in interventional rooms is possible to reach these limits especially without using protective equipment. The aim of this study was to calculate the scattered energy spectra distribution at the level of the operator's head. For this purpose, an in-house developed Monte Carlo-based computer application was used to design computational phantoms (patient and operator), the acquisition geometry as well as to simulate the photon transport through the designed system. The initial spectra from 70 kV tube voltage and 8 different filtrations were calculated according to the IPEM Report 78. An experimental study was carried out to verify the results from the simulations. The calculated scattered radiation distributions were compared to the initial incident on the patient spectra. Results showed that there is no large difference between the effective energies of the scattered spectra registered in front of the operator's head obtained from simulations of all 8 incident spectra. The results from the experimental study agreed well to simulations as well.

  15. Parallel Solver for Diffuse Optical Tomography on Realistic Head Models With Scattering and Clear Regions.

    PubMed

    Placati, Silvio; Guermandi, Marco; Samore, Andrea; Scarselli, Eleonora Franchi; Guerrieri, Roberto

    2016-09-01

    Diffuse optical tomography is an imaging technique, based on evaluation of how light propagates within the human head to obtain the functional information about the brain. Precision in reconstructing such an optical properties map is highly affected by the accuracy of the light propagation model implemented, which needs to take into account the presence of clear and scattering tissues. We present a numerical solver based on the radiosity-diffusion model, integrating the anatomical information provided by a structural MRI. The solver is designed to run on parallel heterogeneous platforms based on multiple GPUs and CPUs. We demonstrate how the solver provides a 7 times speed-up over an isotropic-scattered parallel Monte Carlo engine based on a radiative transport equation for a domain composed of 2 million voxels, along with a significant improvement in accuracy. The speed-up greatly increases for larger domains, allowing us to compute the light distribution of a full human head ( ≈ 3 million voxels) in 116 s for the platform used.

  16. Two-argument total scatter factor for small fields simultaneously collimated by MLC and jaws: application to stereotactic radiosurgery and radiotherapy

    NASA Astrophysics Data System (ADS)

    Han, Zhaohui; Friesen, Scott; Hacker, Fred; Zygmanski, Piotr

    2018-01-01

    Direct use of the total scatter factor (S tot) for independent monitor unit (MU) calculations can be a good alternative approach to the traditional separate treatment of head/collimator scatter (S c) and phantom scatter (S p), especially for stereotactic small fields under the simultaneous collimation of secondary jaws and tertiary multileaf collimators (MLC). We have carried out the measurement of S tot in water for field sizes down to 0.5  ×  0.5 cm2 on a Varian TrueBeam STx medical linear accelerator (linac) equipped with high definition MLCs. Both the jaw field size (c) and MLC field size (s) significantly impact the linac output factors, especially when c \\gg s and s is small (e.g. s  <  5 cm). The combined influence of MLC and jaws gives rise to a two-argument dependence of the total scatter factor, S tot(c,s), which is difficult to functionally decouple. The (c,s) dependence can be conceived as a set of s-dependent functions (‘branches’) defined on domain [s min, s max  =  c] for a given jaw size of c. We have also developed a heuristic model of S tot to assist the clinical implementation of the measured S tot data for small field dosimetry. The model has two components: (i) empirical fit formula for the s-dependent branches and (ii) interpolation scheme between the branches. The interpolation scheme preserves the characteristic shape of the measured branches and effectively transforms the measured trapezoidal domain in (c,s) plane to a rectangular domain to facilitate easier two-dimensional interpolation to determine S tot for arbitrary (c,s) combinations. Both the empirical fit and interpolation showed good agreement with experimental validation data.

  17. Data consistency-driven scatter kernel optimization for x-ray cone-beam CT

    NASA Astrophysics Data System (ADS)

    Kim, Changhwan; Park, Miran; Sung, Younghun; Lee, Jaehak; Choi, Jiyoung; Cho, Seungryong

    2015-08-01

    Accurate and efficient scatter correction is essential for acquisition of high-quality x-ray cone-beam CT (CBCT) images for various applications. This study was conducted to demonstrate the feasibility of using the data consistency condition (DCC) as a criterion for scatter kernel optimization in scatter deconvolution methods in CBCT. As in CBCT, data consistency in the mid-plane is primarily challenged by scatter, we utilized data consistency to confirm the degree of scatter correction and to steer the update in iterative kernel optimization. By means of the parallel-beam DCC via fan-parallel rebinning, we iteratively optimized the scatter kernel parameters, using a particle swarm optimization algorithm for its computational efficiency and excellent convergence. The proposed method was validated by a simulation study using the XCAT numerical phantom and also by experimental studies using the ACS head phantom and the pelvic part of the Rando phantom. The results showed that the proposed method can effectively improve the accuracy of deconvolution-based scatter correction. Quantitative assessments of image quality parameters such as contrast and structure similarity (SSIM) revealed that the optimally selected scatter kernel improves the contrast of scatter-free images by up to 99.5%, 94.4%, and 84.4%, and of the SSIM in an XCAT study, an ACS head phantom study, and a pelvis phantom study by up to 96.7%, 90.5%, and 87.8%, respectively. The proposed method can achieve accurate and efficient scatter correction from a single cone-beam scan without need of any auxiliary hardware or additional experimentation.

  18. TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fetterly, K; Schueler, B; Grams, M

    Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Directmore » exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.« less

  19. WE-EF-207-03: Design and Optimization of a CBCT Head Scanner for Detection of Acute Intracranial Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, J; Sisniega, A; Zbijewski, W

    Purpose: To design a dedicated x-ray cone-beam CT (CBCT) system suitable to deployment at the point-of-care and offering reliable detection of acute intracranial hemorrhage (ICH), traumatic brain injury (TBI), stroke, and other head and neck injuries. Methods: A comprehensive task-based image quality model was developed to guide system design and optimization of a prototype head scanner suitable to imaging of acute TBI and ICH. Previously reported models were expanded to include the effects of x-ray scatter correction necessary for detection of low contrast ICH and the contribution of bit depth (digitization noise) to imaging performance. Task-based detectablity index provided themore » objective function for optimization of system geometry, x-ray source, detector type, anti-scatter grid, and technique at 10–25 mGy dose. Optimal characteristics were experimentally validated using a custom head phantom with 50 HU contrast ICH inserts imaged on a CBCT imaging bench allowing variation of system geometry, focal spot size, detector, grid selection, and x-ray technique. Results: The model guided selection of system geometry with a nominal source-detector distance 1100 mm and optimal magnification of 1.50. Focal spot size ∼0.6 mm was sufficient for spatial resolution requirements in ICH detection. Imaging at 90 kVp yielded the best tradeoff between noise and contrast. The model provided quantitation of tradeoffs between flat-panel and CMOS detectors with respect to electronic noise, field of view, and readout speed required for imaging of ICH. An anti-scatter grid was shown to provide modest benefit in conjunction with post-acquisition scatter correction. Images of the head phantom demonstrate visualization of millimeter-scale simulated ICH. Conclusions: Performance consistent with acute TBI and ICH detection is feasible with model-based system design and robust artifact correction in a dedicated head CBCT system. Further improvements can be achieved with incorporation of model-based iterative reconstruction techniques also within the scope of the task-based optimization framework. David Foos and Xiaohui Wang are employees of Carestream Health.« less

  20. Constituent components of out-of-field scatter dose for 18-MV intensity modulated radiation therapy versus 3-dimensional conformal radiation therapy: a comparison with 6-MV and implications for carcinogenesis.

    PubMed

    Ruben, Jeremy D; Smith, Ryan; Lancaster, Craig M; Haynes, Matthew; Jones, Phillip; Panettieri, Vanessa

    2014-11-01

    To characterize and compare the components of out-of-field dose for 18-MV intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) and their 6-MV counterparts and consider implications for second cancer induction. Comparable plans for each technique/energy were delivered to a water phantom with a sloping wall; under full scatter conditions; with field edge abutting but outside the bath to prevent internal/phantom scatter; and with shielding below the linear accelerator head to attenuate head leakage. Neutron measurements were obtained from published studies. Eighteen-megavolt IMRT produces 1.7 times more out-of-field scatter than 18-MV 3D-CRT. In absolute terms, however, differences are just approximately 0.1% of central axis dose. Eighteen-megavolt IMRT reduces internal/patient scatter by 13%, but collimator scatter (C) is 2.6 times greater than 18-MV 3D-CRT. Head leakage (L) is minimal. Increased out-of-field photon scatter from 18-MV IMRT carries out-of-field second cancer risks of approximately 0.2% over and above the 0.4% from 18-MV 3D-CRT. Greater photoneutron dose from 18-MV IMRT may result in further maximal, absolute increased risk to peripheral tissue of approximately 1.2% over 18-MV 3D-CRT. Out-of-field photon scatter remains comparable for the same modality irrespective of beam energy. Machine scatter (C+L) from 18 versus 6 MV is 1.2 times higher for IMRT and 1.8 times for 3D-CRT. It is 4 times higher for 6-MV IMRT versus 3D-CRT. Reduction in internal scatter with 18 MV versus 6 MV is 27% for 3D-CRT and 29% for IMRT. Compared with 6-MV 3D-CRT, 18-MV IMRT increases out-of-field second cancer risk by 0.2% from photons and adds 0.28-2.2% from neutrons. Out-of-field photon dose seems to be independent of beam energy for both techniques. Eighteen-megavolt IMRT increases out-of-field scatter 1.7-fold over 3D-CRT because of greater collimator scatter despite reducing internal/patient scatter. Out-of-field carcinogenic risk is thus increased (but improved in-field dose conformity may offset this). Potentially increased carcinogenic risk should be weighed against any benefit 18-MV IMRT may provide. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Constituent Components of Out-of-Field Scatter Dose for 18-MV Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy: A Comparison With 6-MV and Implications for Carcinogenesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruben, Jeremy D., E-mail: jeremy.ruben@wbrc.org.au; Department of Surgery, Monash University, Melbourne; Smith, Ryan

    Purpose: To characterize and compare the components of out-of-field dose for 18-MV intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) and their 6-MV counterparts and consider implications for second cancer induction. Methods and Materials: Comparable plans for each technique/energy were delivered to a water phantom with a sloping wall; under full scatter conditions; with field edge abutting but outside the bath to prevent internal/phantom scatter; and with shielding below the linear accelerator head to attenuate head leakage. Neutron measurements were obtained from published studies. Results: Eighteen-megavolt IMRT produces 1.7 times more out-of-field scatter than 18-MV 3D-CRT. Inmore » absolute terms, however, differences are just approximately 0.1% of central axis dose. Eighteen-megavolt IMRT reduces internal/patient scatter by 13%, but collimator scatter (C) is 2.6 times greater than 18-MV 3D-CRT. Head leakage (L) is minimal. Increased out-of-field photon scatter from 18-MV IMRT carries out-of-field second cancer risks of approximately 0.2% over and above the 0.4% from 18-MV 3D-CRT. Greater photoneutron dose from 18-MV IMRT may result in further maximal, absolute increased risk to peripheral tissue of approximately 1.2% over 18-MV 3D-CRT. Out-of-field photon scatter remains comparable for the same modality irrespective of beam energy. Machine scatter (C+L) from 18 versus 6 MV is 1.2 times higher for IMRT and 1.8 times for 3D-CRT. It is 4 times higher for 6-MV IMRT versus 3D-CRT. Reduction in internal scatter with 18 MV versus 6 MV is 27% for 3D-CRT and 29% for IMRT. Compared with 6-MV 3D-CRT, 18-MV IMRT increases out-of-field second cancer risk by 0.2% from photons and adds 0.28-2.2% from neutrons. Conclusions: Out-of-field photon dose seems to be independent of beam energy for both techniques. Eighteen-megavolt IMRT increases out-of-field scatter 1.7-fold over 3D-CRT because of greater collimator scatter despite reducing internal/patient scatter. Out-of-field carcinogenic risk is thus increased (but improved in-field dose conformity may offset this). Potentially increased carcinogenic risk should be weighed against any benefit 18-MV IMRT may provide.« less

  2. SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, X; Zhang, Z; Xie, Y

    Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads tomore » the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation therapy. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)« less

  3. Spatial frequency spectrum of the x-ray scatter distribution in CBCT projections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bootsma, G. J.; Verhaegen, F.; Department of Oncology, Medical Physics Unit, McGill University, Montreal, Quebec H3G 1A4

    2013-11-15

    Purpose: X-ray scatter is a source of significant image quality loss in cone-beam computed tomography (CBCT). The use of Monte Carlo (MC) simulations separating primary and scattered photons has allowed the structure and nature of the scatter distribution in CBCT to become better elucidated. This work seeks to quantify the structure and determine a suitable basis function for the scatter distribution by examining its spectral components using Fourier analysis.Methods: The scatter distribution projection data were simulated using a CBCT MC model based on the EGSnrc code. CBCT projection data, with separated primary and scatter signal, were generated for a 30.6more » cm diameter water cylinder [single angle projection with varying axis-to-detector distance (ADD) and bowtie filters] and two anthropomorphic phantoms (head and pelvis, 360 projections sampled every 1°, with and without a compensator). The Fourier transform of the resulting scatter distributions was computed and analyzed both qualitatively and quantitatively. A novel metric called the scatter frequency width (SFW) is introduced to determine the scatter distribution's frequency content. The frequency content results are used to determine a set basis functions, consisting of low-frequency sine and cosine functions, to fit and denoise the scatter distribution generated from MC simulations using a reduced number of photons and projections. The signal recovery is implemented using Fourier filtering (low-pass Butterworth filter) and interpolation. Estimates of the scatter distribution are used to correct and reconstruct simulated projections.Results: The spatial and angular frequencies are contained within a maximum frequency of 0.1 cm{sup −1} and 7/(2π) rad{sup −1} for the imaging scenarios examined, with these values varying depending on the object and imaging setup (e.g., ADD and compensator). These data indicate spatial and angular sampling every 5 cm and π/7 rad (∼25°) can be used to properly capture the scatter distribution, with reduced sampling possible depending on the imaging scenario. Using a low-pass Butterworth filter, tuned with the SFW values, to denoise the scatter projection data generated from MC simulations using 10{sup 6} photons resulted in an error reduction of greater than 85% for the estimating scatter in single and multiple projections. Analysis showed that the use of a compensator helped reduce the error in estimating the scatter distribution from limited photon simulations by more than 37% when compared to the case without a compensator for the head and pelvis phantoms. Reconstructions of simulated head phantom projections corrected by the filtered and interpolated scatter estimates showed improvements in overall image quality.Conclusions: The spatial frequency content of the scatter distribution in CBCT is found to be contained within the low frequency domain. The frequency content is modulated both by object and imaging parameters (ADD and compensator). The low-frequency nature of the scatter distribution allows for a limited set of sine and cosine basis functions to be used to accurately represent the scatter signal in the presence of noise and reduced data sampling decreasing MC based scatter estimation time. Compensator induced modulation of the scatter distribution reduces the frequency content and improves the fitting results.« less

  4. TH-A-18C-04: Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Y; Southern Medical University, Guangzhou; Bai, T

    2014-06-15

    Purpose: Scatter artifacts severely degrade image quality of cone-beam CT (CBCT). We present an ultrafast scatter correction framework by using GPU-based Monte Carlo (MC) simulation and prior patient CT image, aiming at automatically finish the whole process including both scatter correction and reconstructions within 30 seconds. Methods: The method consists of six steps: 1) FDK reconstruction using raw projection data; 2) Rigid Registration of planning CT to the FDK results; 3) MC scatter calculation at sparse view angles using the planning CT; 4) Interpolation of the calculated scatter signals to other angles; 5) Removal of scatter from the raw projections;more » 6) FDK reconstruction using the scatter-corrected projections. In addition to using GPU to accelerate MC photon simulations, we also use a small number of photons and a down-sampled CT image in simulation to further reduce computation time. A novel denoising algorithm is used to eliminate MC scatter noise caused by low photon numbers. The method is validated on head-and-neck cases with simulated and clinical data. Results: We have studied impacts of photo histories, volume down sampling factors on the accuracy of scatter estimation. The Fourier analysis was conducted to show that scatter images calculated at 31 angles are sufficient to restore those at all angles with <0.1% error. For the simulated case with a resolution of 512×512×100, we simulated 10M photons per angle. The total computation time is 23.77 seconds on a Nvidia GTX Titan GPU. The scatter-induced shading/cupping artifacts are substantially reduced, and the average HU error of a region-of-interest is reduced from 75.9 to 19.0 HU. Similar results were found for a real patient case. Conclusion: A practical ultrafast MC-based CBCT scatter correction scheme is developed. The whole process of scatter correction and reconstruction is accomplished within 30 seconds. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China (2011A081402003)« less

  5. [Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions].

    PubMed

    Galster, M; Guhl, C; Uder, M; Adamus, R

    2013-05-01

    Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. The exposition of the lens of about 110 to 550 μSv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25°LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Coherent Raman Scattering Microscopy for Evaluation of Head and Neck Carcinoma.

    PubMed

    Hoesli, Rebecca C; Orringer, Daniel A; McHugh, Jonathan B; Spector, Matthew E

    2017-09-01

    Objective We aim to describe a novel, label-free, real-time imaging technique, coherent Raman scattering (CRS) microscopy, for histopathological evaluation of head and neck cancer. We evaluated the ability of CRS microscopy to delineate between tumor and nonneoplastic tissue in tissue samples from patients with head and neck cancer. Study Design Prospective case series. Setting Tertiary care medical center. Subjects and Methods Patients eligible were surgical candidates with biopsy-proven, previously untreated head and neck carcinoma and were consented preoperatively for participation in this study. Tissue was collected from 50 patients, and after confirmation of tumor and normal specimens by hematoxylin and eosin (H&E), there were 42 tumor samples and 42 normal adjacent controls. Results There were 42 confirmed carcinoma specimens on H&E, and CRS microscopy identified 37 as carcinoma. Of the 42 normal specimens, CRS microscopy identified 40 as normal. This resulted in a sensitivity of 88.1% and specificity of 95.2% in distinguishing between neoplastic and nonneoplastic images. Conclusion CRS microscopy is a unique label-free imaging technique that can provide rapid, high-resolution images and can accurately determine the presence of head and neck carcinoma. This holds potential for implementation into standard practice, allowing frozen margin evaluation even at institutions without a histopathology laboratory.

  7. Poster — Thur Eve — 43: Monte Carlo Modeling of Flattening Filter Free Beams and Studies of Relative Output Factors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhan, Lixin; Jiang, Runqing; Osei, Ernest K.

    2014-08-15

    Flattening filter free (FFF) beams have been adopted by many clinics and used for patient treatment. However, compared to the traditional flattened beams, we have limited knowledge of FFF beams. In this study, we successfully modeled the 6 MV FFF beam for Varian TrueBeam accelerator with the Monte Carlo (MC) method. Both the percentage depth dose and profiles match well to the Golden Beam Data (GBD) from Varian. MC simulations were then performed to predict the relative output factors. The in-water output ratio, Scp, was simulated in water phantom and data obtained agrees well with GBD. The in-air output ratio,more » Sc, was obtained by analyzing the phase space placed at isocenter, in air, and computing the ratio of water Kerma rates for different field sizes. The phantom scattering factor, Sp, can then be obtained from the traditional way of taking the ratio of Scp and Sc. We also simulated Sp using a recently proposed method based on only the primary beam dose delivery in water phantom. Because there is no concern of lateral electronic disequilibrium, this method is more suitable for small fields. The results from both methods agree well with each other. The flattened 6 MV beam was simulated and compared to 6 MV FFF. The comparison confirms that 6 MV FFF has less scattering from the Linac head and less phantom scattering contribution to the central axis dose, which will be helpful for improving accuracy in beam modeling and dose calculation in treatment planning systems.« less

  8. Scattered radiation from dental metallic crowns in head and neck radiotherapy.

    PubMed

    Shimozato, T; Igarashi, Y; Itoh, Y; Yamamoto, N; Okudaira, K; Tabushi, K; Obata, Y; Komori, M; Naganawa, S; Ueda, M

    2011-09-07

    We aimed to estimate the scattered radiation from dental metallic crowns during head and neck radiotherapy by irradiating a jaw phantom with external photon beams. The phantom was composed of a dental metallic plate and hydroxyapatite embedded in polymethyl methacrylate. We used radiochromic film measurement and Monte Carlo simulation to calculate the radiation dose and dose distribution inside the phantom. To estimate dose variations in scattered radiation under different clinical situations, we altered the incident energy, field size, plate thickness, plate depth and plate material. The simulation results indicated that the dose at the incident side of the metallic dental plate was approximately 140% of that without the plate. The differences between dose distributions calculated with the radiation treatment-planning system (TPS) algorithms and the data simulation, except around the dental metallic plate, were 3% for a 4 MV photon beam. Therefore, we should carefully consider the dose distribution around dental metallic crowns determined by a TPS.

  9. Scattered radiation from dental metallic crowns in head and neck radiotherapy

    NASA Astrophysics Data System (ADS)

    Shimozato, T.; Igarashi, Y.; Itoh, Y.; Yamamoto, N.; Okudaira, K.; Tabushi, K.; Obata, Y.; Komori, M.; Naganawa, S.; Ueda, M.

    2011-09-01

    We aimed to estimate the scattered radiation from dental metallic crowns during head and neck radiotherapy by irradiating a jaw phantom with external photon beams. The phantom was composed of a dental metallic plate and hydroxyapatite embedded in polymethyl methacrylate. We used radiochromic film measurement and Monte Carlo simulation to calculate the radiation dose and dose distribution inside the phantom. To estimate dose variations in scattered radiation under different clinical situations, we altered the incident energy, field size, plate thickness, plate depth and plate material. The simulation results indicated that the dose at the incident side of the metallic dental plate was approximately 140% of that without the plate. The differences between dose distributions calculated with the radiation treatment-planning system (TPS) algorithms and the data simulation, except around the dental metallic plate, were 3% for a 4 MV photon beam. Therefore, we should carefully consider the dose distribution around dental metallic crowns determined by a TPS.

  10. Design and Experimental Evaluation of a Non-Invasive Microwave Head Imaging System for Intracranial Haemorrhage Detection

    PubMed Central

    Mobashsher, A. T.; Bialkowski, K. S.; Abbosh, A. M.; Crozier, S.

    2016-01-01

    An intracranial haemorrhage is a life threatening medical emergency, yet only a fraction of the patients receive treatment in time, primarily due to the transport delay in accessing diagnostic equipment in hospitals such as Magnetic Resonance Imaging or Computed Tomography. A mono-static microwave head imaging system that can be carried in an ambulance for the detection and localization of intracranial haemorrhage is presented. The system employs a single ultra-wideband antenna as sensing element to transmit signals in low microwave frequencies towards the head and capture backscattered signals. The compact and low-profile antenna provides stable directional radiation patterns over the operating bandwidth in both near and far-fields. Numerical analysis of the head imaging system with a realistic head model in various situations is performed to realize the scattering mechanism of haemorrhage. A modified delay-and-summation back-projection algorithm, which includes effects of surface waves and a distance-dependent effective permittivity model, is proposed for signal and image post-processing. The efficacy of the automated head imaging system is evaluated using a 3D-printed human head phantom with frequency dispersive dielectric properties including emulated haemorrhages with different sizes located at different depths. Scattered signals are acquired with a compact transceiver in a mono-static circular scanning profile. The reconstructed images demonstrate that the system is capable of detecting haemorrhages as small as 1 cm3. While quantitative analyses reveal that the quality of images gradually degrades with the increase of the haemorrhage’s depth due to the reduction of signal penetration inside the head; rigorous statistical analysis suggests that substantial improvement in image quality can be obtained by increasing the data samples collected around the head. The proposed head imaging prototype along with the processing algorithm demonstrates its feasibility for potential use in ambulances as an effective and low cost diagnostic tool to assure timely triaging of intracranial hemorrhage patients. PMID:27073994

  11. Laser scattering by transcranial rat brain illumination

    NASA Astrophysics Data System (ADS)

    Sousa, Marcelo V. P.; Prates, Renato; Kato, Ilka T.; Sabino, Caetano P.; Suzuki, Luis C.; Ribeiro, Martha S.; Yoshimura, Elisabeth M.

    2012-06-01

    Due to the great number of applications of Low-Level-Laser-Therapy (LLLT) in Central Nervous System (CNS), the study of light penetration through skull and distribution in the brain becomes extremely important. The aim is to analyze the possibility of precise illumination of deep regions of the rat brain, measure the penetration and distribution of red (λ = 660 nm) and Near Infra-Red (NIR) (λ = 808 nm) diode laser light and compare optical properties of brain structures. The head of the animal (Rattus Novergicus) was epilated and divided by a sagittal cut, 2.3 mm away from mid plane. This section of rat's head was illuminated with red and NIR lasers in points above three anatomical structures: hippocampus, cerebellum and frontal cortex. A high resolution camera, perpendicularly positioned, was used to obtain images of the brain structures. Profiles of scattered intensities in the laser direction were obtained from the images. There is a peak in the scattered light profile corresponding to the skin layer. The bone layer gives rise to a valley in the profile indicating low scattering coefficient, or frontal scattering. Another peak in the region related to the brain is an indication of high scattering coefficient (μs) for this tissue. This work corroborates the use of transcranial LLLT in studies with rats which are subjected to models of CNS diseases. The outcomes of this study point to the possibility of transcranial LLLT in humans for a large number of diseases.

  12. Robustness of a compact endfire personal audio system against scattering effects (L).

    PubMed

    Tu, Zhen; Lu, Jing; Qiu, Xiaojun

    2016-10-01

    Compact loudspeaker arrays have wide potential applications as portable personal audio systems that can project sound energy to specified regions. It is meaningful to investigate the scattering effects on the array performance since the scattering of the users' heads is inevitable in practice. A five-channel compact endfire array is established and the regularized acoustic contrast control method is evaluated for the scenarios of one moving listener and one listener fixed in the bright zone while another listener moves along the evaluation region. Both simulations and experiments verify that the scattering has limited influence on the directivity of the endfire array.

  13. Head and facial injuries due to cluster munitions.

    PubMed

    Fares, Youssef; Fares, Jawad; Gebeily, Souheil

    2014-06-01

    Cluster munitions are weapons that scatter smaller sub-munitions intended to kill or mutilate on impact. They have been used by the Israeli army in the south of Lebanon and are now scattered over wide rural areas affecting its inhabitants. Because of their easily "pickable" nature, sub-munitions can inflict injuries to the head and face regions. In this study, we aimed to explore the head and face injuries along with their clinical features in a group of Lebanese patients who suffered from such injuries due to a sub-munition's detonation. The study included all the cases reported between 14 August 2006 and 15 February 2013, with head and face injuries related to cluster bombs. Injuries were classified into brain, eye, otologic and auditory impairments, oral and maxillofacial, and skin and soft-tissue injuries. Psychological effects of these patients were also examined as for post-traumatic stress disorder, major depressive disorder, generalized anxiety disorder and acute stress syndrome. During the study period, there were 417 casualties as a result of cluster munitions' blasts. Out of the total number of victims, 29 (7 %) were injured in the head and the face region. The convention on cluster munitions of 2008 should be adhered to, as these inhumane weapons indiscriminately and disproportionately harm innocent civilians, thereby violating the well-established international principles governing conflict and war today.

  14. Photothermal measurement of absorption and scattering losses in thin films excited by surface plasmons.

    PubMed

    Domené, Esteban A; Balzarotti, Francisco; Bragas, Andrea V; Martínez, Oscar E

    2009-12-15

    We present a novel noncontact, photothermal technique, based on the focus error signal of a commercial CD pickup head that allows direct determination of absorption in thin films. Combined with extinction methods, this technique yields the scattering contribution to the losses. Surface plasmon polaritons are excited using the Kretschmann configuration in thin Au films of varying thickness. By measuring the extinction and absorption simultaneously, it is shown that dielectric constants and thickness retrieval leads to inconsistencies if the model does not account for scattering.

  15. MO-FG-CAMPUS-JeP1-05: Water Equivalent Path Length Calculations Using Scatter-Corrected Head and Neck CBCT Images to Evaluate Patients for Adaptive Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J; Park, Y; Sharp, G

    Purpose: To establish a method to evaluate the dosimetric impact of anatomic changes in head and neck patients during proton therapy by using scatter-corrected cone-beam CT (CBCT) images. Methods: The water equivalent path length (WEPL) was calculated to the distal edge of PTV contours by using tomographic images available for six head and neck patients received photon therapy. The proton range variation was measured by calculating the difference between the distal WEPLs calculated with the planning CT and weekly treatment CBCT images. By performing an automatic rigid registration, six degrees-of-freedom (DOF) correction was made to the CBCT images to accountmore » for the patient setup uncertainty. For accurate WEPL calculations, an existing CBCT scatter correction algorithm, whose performance was already proven for phantom images, was calibrated for head and neck patient images. Specifically, two different image similarity measures, mutual information (MI) and mean square error (MSE), were tested for the deformable image registration (DIR) in the CBCT scatter correction algorithm. Results: The impact of weight loss was reflected in the distal WEPL differences with the aid of the automatic rigid registration reducing the influence of patient setup uncertainty on the WEPL calculation results. The WEPL difference averaged over distal area was 2.9 ± 2.9 (mm) across all fractions of six patients and its maximum, mostly found at the last available fraction, was 6.2 ± 3.4 (mm). The MSE-based DIR successfully registered each treatment CBCT image to the planning CT image. On the other hand, the MI-based DIR deformed the skin voxels in the planning CT image to the immobilization mask in the treatment CBCT image, most of which was cropped out of the planning CT image. Conclusion: The dosimetric impact of anatomic changes was evaluated by calculating the distal WEPL difference with the existing scatter-correction algorithm appropriately calibrated. Jihun Kim, Yang-Kyun Park, Gregory Sharp, and Brian Winey have received grant support from the NCI Federal Share of program income earned by Massachusetts General Hospital on C06 CA059267, Proton Therapy Research and Treatment Center.« less

  16. Effective scattering coefficient of the cerebral spinal fluid in adult head models for diffuse optical imaging

    NASA Astrophysics Data System (ADS)

    Custo, Anna; Wells, William M., III; Barnett, Alex H.; Hillman, Elizabeth M. C.; Boas, David A.

    2006-07-01

    An efficient computation of the time-dependent forward solution for photon transport in a head model is a key capability for performing accurate inversion for functional diffuse optical imaging of the brain. The diffusion approximation to photon transport is much faster to simulate than the physically correct radiative transport equation (RTE); however, it is commonly assumed that scattering lengths must be much smaller than all system dimensions and all absorption lengths for the approximation to be accurate. Neither of these conditions is satisfied in the cerebrospinal fluid (CSF). Since line-of-sight distances in the CSF are small, of the order of a few millimeters, we explore the idea that the CSF scattering coefficient may be modeled by any value from zero up to the order of the typical inverse line-of-sight distance, or approximately 0.3 mm-1, without significantly altering the calculated detector signals or the partial path lengths relevant for functional measurements. We demonstrate this in detail by using a Monte Carlo simulation of the RTE in a three-dimensional head model based on clinical magnetic resonance imaging data, with realistic optode geometries. Our findings lead us to expect that the diffusion approximation will be valid even in the presence of the CSF, with consequences for faster solution of the inverse problem.

  17. Size And Shape of Detergent Micelles Determined By Small-Angle X-Ray Scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lipfert, Jan; Columbus, Linda; Chu, Vincent B.

    2009-04-29

    We present a systematic analysis of the aggregation number and shape of micelles formed by nine detergents commonly used in the study of membrane proteins. Small-angle X-ray scattering measurements are reported for glucosides with 8 and 9 alkyl carbons (OG/NG), maltosides and phosphocholines with 10 and 12 alkyl carbons (DM/DDM and FC-10/FC-12), 1,2-dihexanoyl-sn-glycero-phosphocholine (DHPC), 1-palmitoyl-2-hydroxy-sn-glycero-3-[phospho-rac-(1-glycerol)] (LPPG), and 3-[(3-cholamidopropyl)dimethylammonio]-1-propane sulfonate (CHAPS). The SAXS intensities are well described by two-component ellipsoid models, with a dense outer shell corresponding to the detergent head groups and a less electron dense hydrophobic core. These models provide an intermediate resolution view of micelle size and shape.more » In addition, we show that Guinier analysis of the forward scattering intensity can be used to obtain an independent and model-free measurement of the micelle aggregation number and radius of gyration. This approach has the advantage of being easily generalizable to protein-detergent complexes, where simple geometric models are inapplicable. Furthermore, we have discovered that the position of the second maximum in the scattering intensity provides a direct measurement of the characteristic head group-head group spacing across the micelle core. Our results for the micellar aggregation numbers and dimensions agree favorably with literature values as far as they are available. We de novo determine the shape of FC-10, FC-12, DM, LPPG, and CHAPS micelles and the aggregation numbers of FC-10 and OG to be ca. 50 and 250, respectively. Combined, these data provide a comprehensive view of the determinants of micelle formation and serve as a starting point to correlate detergent properties with detergent-protein interactions.« less

  18. Accounting for the fringe magnetic field from the bending magnet in a Monte Carlo accelerator treatment head simulation.

    PubMed

    O'Shea, Tuathan P; Foley, Mark J; Faddegon, Bruce A

    2011-06-01

    Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the full range of clinical field sizes and patient positions. Recently, disassembly of the treatment head of a linear accelerator has been used to refine the simulation of the electron beam, setting tightly measured constraints on source and geometry parameters used in simulation. The simulation did not explicitly include the known deflection of the electron beam by a fringe magnetic field from the bending magnet, which extended into the treatment head. Instead, the secondary scattering foil and monitor chamber were unrealistically laterally offset to account for the beam deflection. This work is focused on accounting for this fringe magnetic field in treatment head simulation. The magnetic field below the exit window of a Siemens Oncor linear accelerator was measured with a Tesla-meter from 0 to 12 cm from the exit window and 1-3 cm off-axis. Treatment head simulation was performed with the EGSnrc/BEAMnrc code, modified to incorporate the effect of the magnetic field on charged particle transport. Simulations were used to analyze the sensitivity of dose profiles to various sources of asymmetry in the treatment head. This included the lateral spot offset and beam angle at the exit window, the fringe magnetic field and independent lateral offsets of the secondary scattering foil and electron monitor chamber. Simulation parameters were selected within the limits imposed by measurement uncertainties. Calculated dose distributions were then compared with those measured in water. The magnetic field was a maximum at the exit window, increasing from 0.006 T at 6 MeV to 0.020 T at 21 MeV and dropping to approximately 5% of the maximum at the secondary scattering foil. It was up to three times higher in the bending plane, away from the electron gun, and symmetric within measurement uncertainty in the transverse plane. Simulations showed the magnetic field resulted in an offset of the electron beam of 0.80 cm (mean) at the machine isocenter for the exit window only configuration. The fringe field resulted in a 3.5%-7.6% symmetry and 0.25-0.35 cm offset of the clinical beam R(max) profiles. With the magnetic field included in simulations, a single (realistic) position of the secondary scattering foil and monitor chamber was selected. Measured and simulated dose profiles showed agreement to an average of 2.5%/0.16 cm (maximum: 3%/0.2 cm), which is a better match than previously achieved without incorporating the magnetic field in the simulation. The undulations from the 3 stepped layers of the secondary scattering foil, evident in the measured profiles of the higher energy beams, are now aligned with those in the simulated beam. The simulated fringe magnetic field had negligible effect on the central axis depth dose curves and cross-plane dose profiles. The fringe magnetic field is a significant contributor to the electron beam in-plane asymmetry. With the magnetic field included explicitly in the simulation, realistic monitor chamber and secondary scattering foil positions have been achieved, and the calculated fluence and dose distributions are more accurate.

  19. Clinical implementation of intraoperative cone-beam CT in head and neck surgery

    NASA Astrophysics Data System (ADS)

    Daly, M. J.; Chan, H.; Nithiananthan, S.; Qiu, J.; Barker, E.; Bachar, G.; Dixon, B. J.; Irish, J. C.; Siewerdsen, J. H.

    2011-03-01

    A prototype mobile C-arm for cone-beam CT (CBCT) has been translated to a prospective clinical trial in head and neck surgery. The flat-panel CBCT C-arm was developed in collaboration with Siemens Healthcare, and demonstrates both sub-mm spatial resolution and soft-tissue visibility at low radiation dose (e.g., <1/5th of a typical diagnostic head CT). CBCT images are available ~15 seconds after scan completion (~1 min acquisition) and reviewed at bedside using custom 3D visualization software based on the open-source Image-Guided Surgery Toolkit (IGSTK). The CBCT C-arm has been successfully deployed in 15 head and neck cases and streamlined into the surgical environment using human factors engineering methods and expert feedback from surgeons, nurses, and anesthetists. Intraoperative imaging is implemented in a manner that maintains operating field sterility, reduces image artifacts (e.g., carbon fiber OR table) and minimizes radiation exposure. Image reviews conducted with surgical staff indicate bony detail and soft-tissue visualization sufficient for intraoperative guidance, with additional artifact management (e.g., metal, scatter) promising further improvements. Clinical trial deployment suggests a role for intraoperative CBCT in guiding complex head and neck surgical tasks, including planning mandible and maxilla resection margins, guiding subcranial and endonasal approaches to skull base tumours, and verifying maxillofacial reconstruction alignment. Ongoing translational research into complimentary image-guidance subsystems include novel methods for real-time tool tracking, fusion of endoscopic video and CBCT, and deformable registration of preoperative volumes and planning contours with intraoperative CBCT.

  20. Thin optical display panel

    DOEpatents

    Veligdan, James Thomas

    1997-01-01

    An optical display includes a plurality of optical waveguides each including a cladding bound core for guiding internal display light between first and second opposite ends by total internal reflection. The waveguides are stacked together to define a collective display thickness. Each of the cores includes a heterogeneous portion defining a light scattering site disposed longitudinally between the first and second ends. Adjacent ones of the sites are longitudinally offset from each other for forming a longitudinal internal image display over the display thickness upon scattering of internal display light thereagainst for generating a display image. In a preferred embodiment, the waveguides and scattering sites are transparent for transmitting therethrough an external image in superposition with the display image formed by scattering the internal light off the scattering sites for defining a heads up display.

  1. Fréchet derivative with respect to the shape of a strongly convex nonscattering region in optical tomography

    NASA Astrophysics Data System (ADS)

    Hyvönen, Nuutti

    2007-10-01

    The aim of optical tomography is to reconstruct the optical properties inside a physical body, e.g. a neonatal head, by illuminating it with near-infrared light and measuring the outward flux of photons on the object boundary. Because a brain consists of strongly scattering tissue with imbedded cavities filled by weakly scattering cerebrospinal fluid, propagation of near-infrared photons in the human head can be treated by combining the diffusion approximation of the radiative transfer equation with geometrical optics to obtain the radiosity-diffusion forward model of optical tomography. At the moment, a disadvantage with the radiosity-diffusion model is that the locations of the transparent cavities must be known in advance in order to be able to reconstruct the physiologically interesting quantities, i.e., the absorption and the scatter in the strongly scattering brain tissue. In this work we show that the boundary measurement map of optical tomography is Fréchet differentiable with respect to the shape of a strongly convex nonscattering region. Using this result, we introduce a numerical algorithm for approximating an unknown nonscattering cavity by a ball if the background diffuse optical properties of the object are known. The functionality of the method is demonstrated through two-dimensional numerical experiments.

  2. Dosimetric measurement of scattered radiation from dental implants in simulated head and neck radiotherapy.

    PubMed

    Wang, R; Pillai, K; Jones, P K

    1998-01-01

    The purpose of this study was to examine the dose enhancement at bone-implant interfaces from scattered radiation during simulated head and neck radiotherapy. Three cylindric implant systems with different compositions (pure titanium, titanium-aluminum-vanadium alloy, titanium coated with hydroxyapatite) and a high gold content transmandibular implant system (gold-copper-silver alloy) were studied. Extruded lithium fluoride single crystal chips were used as thermoluminescent material to measure radiation dose enhancement at 0, 1, and 2 mm from the bone-implant interface. The relative doses in buccal, lingual, mesial, and distal directions were also recorded and compared. The results indicated that the highest dose enhancement occurred at a distance of 0 mm from the bone-implant interface for all the implant systems studied. The transmandibular implants had higher scattered radiation than other groups at 0 mm and at 1 mm from the bone-implant interface. There was no significant difference of dose enhancement between buccal, lingual, mesial, and distal directions. Titanium implants coated with hydroxyapatite demonstrated the best results under the simulated irradiation.

  3. Extracting the frequencies of the pinna spectral notches in measured head related impulse responses

    NASA Astrophysics Data System (ADS)

    Raykar, Vikas C.; Duraiswami, Ramani; Yegnanarayana, B.

    2005-07-01

    The head related impulse response (HRIR) characterizes the auditory cues created by scattering of sound off a person's anatomy. The experimentally measured HRIR depends on several factors such as reflections from body parts (torso, shoulder, and knees), head diffraction, and reflection/diffraction effects due to the pinna. Structural models (Algazi et al., 2002; Brown and Duda, 1998) seek to establish direct relationships between the features in the HRIR and the anatomy. While there is evidence that particular features in the HRIR can be explained by anthropometry, the creation of such models from experimental data is hampered by the fact that the extraction of the features in the HRIR is not automatic. One of the prominent features observed in the HRIR, and one that has been shown to be important for elevation perception, are the deep spectral notches attributed to the pinna. In this paper we propose a method to robustly extract the frequencies of the pinna spectral notches from the measured HRIR, distinguishing them from other confounding features. The method also extracts the resonances described by Shaw (1997). The techniques are applied to the publicly available CIPIC HRIR database (Algazi et al., 2001c). The extracted notch frequencies are related to the physical dimensions and shape of the pinna.

  4. Ionic scattering factors of atoms that compose biological molecules

    PubMed Central

    Matsuoka, Rei; Yamashita, Yoshiki; Yamane, Tsutomu; Kidera, Akinori; Maki-Yonekura, Saori

    2018-01-01

    Ionic scattering factors of atoms that compose biological molecules have been computed by the multi-configuration Dirac–Fock method. These ions are chemically unstable and their scattering factors had not been reported except for O−. Yet these factors are required for the estimation of partial charges in protein molecules and nucleic acids. The electron scattering factors of these ions are particularly important as the electron scattering curves vary considerably between neutral and charged atoms in the spatial-resolution range explored in structural biology. The calculated X-ray and electron scattering factors have then been parameterized for the major scattering curve models used in X-ray and electron protein crystallography and single-particle cryo-EM. The X-ray and electron scattering factors and the fitting parameters are presented for future reference. PMID:29755750

  5. Hexagonal arrays of round-head silicon nanopillars for surface anti-reflection applications

    NASA Astrophysics Data System (ADS)

    Yan, Wensheng; Dottermusch, Stephan; Reitz, Christian; Richards, Bryce S.

    2016-10-01

    We designed and fabricated an anti-reflection surface of hexagonal arrays of round-head silicon nanopillars. The measurements show a significant reduction in reflectivity across a broad spectral range. However, we then grew a conformal titanium dioxide coating via atomic layer deposition to achieve an extremely low weighted average reflection of 2.1% over the 460-1040 nm wavelength range. To understand the underlying reasons for the reduced reflectance, the simulations were conducted and showed that it is due to strong forward scattering of incident light into the silicon substrate. The calculated normalized scattering cross section demonstrates a broadband distribution feature, and the peak has a red-shift to longer wavelengths. Finally, we report two-dimensional weighted average reflectance as a function of both wavelength and angle of incidence and present the resulting analysis contour map.

  6. Fox Squirrels Match Food Assessment and Cache Effort to Value and Scarcity

    PubMed Central

    Delgado, Mikel M.; Nicholas, Molly; Petrie, Daniel J.; Jacobs, Lucia F.

    2014-01-01

    Scatter hoarders must allocate time to assess items for caching, and to carry and bury each cache. Such decisions should be driven by economic variables, such as the value of the individual food items, the scarcity of these items, competition for food items and risk of pilferage by conspecifics. The fox squirrel, an obligate scatter-hoarder, assesses cacheable food items using two overt movements, head flicks and paw manipulations. These behaviors allow an examination of squirrel decision processes when storing food for winter survival. We measured wild squirrels' time allocations and frequencies of assessment and investment behaviors during periods of food scarcity (summer) and abundance (fall), giving the squirrels a series of 15 items (alternating five hazelnuts and five peanuts). Assessment and investment per cache increased when resource value was higher (hazelnuts) or resources were scarcer (summer), but decreased as scarcity declined (end of sessions). This is the first study to show that assessment behaviors change in response to factors that indicate daily and seasonal resource abundance, and that these factors may interact in complex ways to affect food storing decisions. Food-storing tree squirrels may be a useful and important model species to understand the complex economic decisions made under natural conditions. PMID:24671221

  7. Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Min, Jonghwan; Pua, Rizza; Cho, Seungryong, E-mail: scho@kaist.ac.kr

    Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in amore » circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.« less

  8. Modeling of light distribution in the brain for topographical imaging

    NASA Astrophysics Data System (ADS)

    Okada, Eiji; Hayashi, Toshiyuki; Kawaguchi, Hiroshi

    2004-07-01

    Multi-channel optical imaging system can obtain a topographical distribution of the activated region in the brain cortex by a simple mapping algorithm. Near-infrared light is strongly scattered in the head and the volume of tissue that contributes to the change in the optical signal detected with source-detector pair on the head surface is broadly distributed in the brain. This scattering effect results in poor resolution and contrast in the topographic image of the brain activity. We report theoretical investigations on the spatial resolution of the topographic imaging of the brain activity. The head model for the theoretical study consists of five layers that imitate the scalp, skull, subarachnoid space, gray matter and white matter. The light propagation in the head model is predicted by Monte Carlo simulation to obtain the spatial sensitivity profile for a source-detector pair. The source-detector pairs are one dimensionally arranged on the surface of the model and the distance between the adjoining source-detector pairs are varied from 4 mm to 32 mm. The change in detected intensity caused by the absorption change is obtained by Monte Carlo simulation. The position of absorption change is reconstructed by the conventional mapping algorithm and the reconstruction algorithm using the spatial sensitivity profiles. We discuss the effective interval between the source-detector pairs and the choice of reconstruction algorithms to improve the topographic images of brain activity.

  9. Conebeam CT of the head and neck, part 1: physical principles.

    PubMed

    Miracle, A C; Mukherji, S K

    2009-06-01

    Conebeam x-ray CT (CBCT) is a developing imaging technique designed to provide relatively low-dose high-spatial-resolution visualization of high-contrast structures in the head and neck and other anatomic areas. This first installment in a 2-part review will address the physical principles underlying CBCT imaging as it is used in dedicated head and neck scanners. Concepts related to CBCT acquisition geometry, flat panel detection, and image quality will be explored in detail. Particular emphasis will be placed on technical limitations to low-contrast detectability and radiation dose. Proposed methods of x-ray scatter reduction will also be discussed.

  10. A system to track skin dose for neuro-interventional cone-beam computed tomography (CBCT)

    NASA Astrophysics Data System (ADS)

    Vijayan, Sarath; Xiong, Zhenyu; Rudin, Stephen; Bednarek, Daniel R.

    2016-03-01

    The skin-dose tracking system (DTS) provides a color-coded illustration of the cumulative skin-dose distribution on a closely-matching 3D graphic of the patient during fluoroscopic interventions in real-time for immediate feedback to the interventionist. The skin-dose tracking utility of DTS has been extended to include cone-beam computed tomography (CBCT) of neurointerventions. While the DTS was developed to track the entrance skin dose including backscatter, a significant part of the dose in CBCT is contributed by exit primary radiation and scatter due to the many overlapping projections during the rotational scan. The variation of backscatter inside and outside the collimated beam was measured with radiochromic film and a curve was fit to obtain a scatter spread function that could be applied in the DTS. Likewise, the exit dose distribution was measured with radiochromic film for a single projection and a correction factor was determined as a function of path length through the head. Both of these sources of skin dose are added for every projection in the CBCT scan to obtain a total dose mapping over the patient graphic. Results show the backscatter to follow a sigmoidal falloff near the edge of the beam, extending outside the beam as far as 8 cm. The exit dose measured for a cylindrical CTDI phantom was nearly 10 % of the entrance peak skin dose for the central ray. The dose mapping performed by the DTS for a CBCT scan was compared to that measured with radiochromic film and a CTDI-head phantom with good agreement.

  11. Head-on collisions of localized pressure excitations in derivative cubic relaxing media: dynamical structure survey

    NASA Astrophysics Data System (ADS)

    Youssoufa, Saliou; Kamgang Kuetche, Victor; Crepin Kofane, Timoleon

    2015-02-01

    In the wake of the recent derivation of the new cubic nonlinear evolution equation of high-frequency pressure perturbations of a barothropic medium under relaxation (Kuetche V K et al 2014 J. Math. Phys. 55 052702), we closely investigate the head-on collisions of some typical localized waveguide excitations, which are solutions to the previous system. From the viewpoint of Hirota's formalism, we delve into the structural scattering features of the interacting waves mentioned above. As a result, we find that there might exist some ‘characteristic’ amplitude ratio of the interacting waves at which the scattering changes its features. Accordingly, we provide an illustration of the previous result within the depiction of the interactions between three single soliton solutions alongside the phase-shift of each particle. Following these depictions, we address some physical implications of the results as well as the different potential applications.

  12. TH-A-18C-09: Ultra-Fast Monte Carlo Simulation for Cone Beam CT Imaging of Brain Trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisniega, A; Zbijewski, W; Stayman, J

    Purpose: Application of cone-beam CT (CBCT) to low-contrast soft tissue imaging, such as in detection of traumatic brain injury, is challenged by high levels of scatter. A fast, accurate scatter correction method based on Monte Carlo (MC) estimation is developed for application in high-quality CBCT imaging of acute brain injury. Methods: The correction involves MC scatter estimation executed on an NVIDIA GTX 780 GPU (MC-GPU), with baseline simulation speed of ~1e7 photons/sec. MC-GPU is accelerated by a novel, GPU-optimized implementation of variance reduction (VR) techniques (forced detection and photon splitting). The number of simulated tracks and projections is reduced formore » additional speed-up. Residual noise is removed and the missing scatter projections are estimated via kernel smoothing (KS) in projection plane and across gantry angles. The method is assessed using CBCT images of a head phantom presenting a realistic simulation of fresh intracranial hemorrhage (100 kVp, 180 mAs, 720 projections, source-detector distance 700 mm, source-axis distance 480 mm). Results: For a fixed run-time of ~1 sec/projection, GPU-optimized VR reduces the noise in MC-GPU scatter estimates by a factor of 4. For scatter correction, MC-GPU with VR is executed with 4-fold angular downsampling and 1e5 photons/projection, yielding 3.5 minute run-time per scan, and de-noised with optimized KS. Corrected CBCT images demonstrate uniformity improvement of 18 HU and contrast improvement of 26 HU compared to no correction, and a 52% increase in contrast-tonoise ratio in simulated hemorrhage compared to “oracle” constant fraction correction. Conclusion: Acceleration of MC-GPU achieved through GPU-optimized variance reduction and kernel smoothing yields an efficient (<5 min/scan) and accurate scatter correction that does not rely on additional hardware or simplifying assumptions about the scatter distribution. The method is undergoing implementation in a novel CBCT dedicated to brain trauma imaging at the point of care in sports and military applications. Research grant from Carestream Health. JY is an employee of Carestream Health.« less

  13. Cell-line-specific stimulation of tumor cell aggressiveness by wound healing factors - a central role for STAT3.

    PubMed

    Ekblad, Lars; Lindgren, Gustaf; Persson, Emma; Kjellén, Elisabeth; Wennerberg, Johan

    2013-01-25

    Local recurrence is a major factor affecting survival after treatment for head and neck squamous cell carcinoma (HNSCC). It is possible that the normal processes involved in wound healing after surgical removal of a primary tumor can boost the regrowth of residual cancer cells, thereby contributing to the recurrent growth. In this work, we collected human wound fluids and used them to investigate the effect of wound healing factors on HNSCC cell lines in vitro. Wound fluids were collected from thyroidectomized patients diagnosed with benign disease and were included in assays of cell proliferation, migration, cell scattering, and invasion. The involvement of intracellular signaling pathways and membrane receptors were investigated by western blotting and the inclusion of specific inhibitors. One out of four cell lines was greatly stimulated in proliferation, migration, cell scattering, and invasion by the addition of wound fluid as compared with addition of fetal bovine or human serum. These effects were accompanied by a sharp increase in activation of signal transducer and activator of transcription 3 (STAT3). Inhibition of STAT3 activation abolished the wound fluid response, showing that STAT3 plays an important role in the wound healing response. Several of the observed phenotypic changes were epithelial-to-mesenchymal transition (EMT)-like, but the appropriate changes were not seen in any of the EMT markers investigated. The involvement of c-Met or epidermal growth factor receptor family members was excluded, while the interleukin-6 receptor was found to be partly responsible for the activation of STAT3. In conclusion, we found cell-line-specific effects of wound healing factors on HNSCC, setting the stage for therapy development and predictive opportunities.

  14. Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stankovic, Uros; Herk, Marcel van; Ploeger, Lennert S.

    Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive inmore » previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study weret{sub cup} for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. Results: The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. Conclusions: The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.« less

  15. Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid.

    PubMed

    Stankovic, Uros; van Herk, Marcel; Ploeger, Lennert S; Sonke, Jan-Jakob

    2014-06-01

    Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study were t(cup) for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.

  16. Photon migration in non-scattering tissue and the effects on image reconstruction

    NASA Astrophysics Data System (ADS)

    Dehghani, H.; Delpy, D. T.; Arridge, S. R.

    1999-12-01

    Photon propagation in tissue can be calculated using the relationship described by the transport equation. For scattering tissue this relationship is often simplified and expressed in terms of the diffusion approximation. This approximation, however, is not valid for non-scattering regions, for example cerebrospinal fluid (CSF) below the skull. This study looks at the effects of a thin clear layer in a simple model representing the head and examines its effect on image reconstruction. Specifically, boundary photon intensities (total number of photons exiting at a point on the boundary due to a source input at another point on the boundary) are calculated using the transport equation and compared with data calculated using the diffusion approximation for both non-scattering and scattering regions. The effect of non-scattering regions on the calculated boundary photon intensities is presented together with the advantages and restrictions of the transport code used. Reconstructed images are then presented where the forward problem is solved using the transport equation for a simple two-dimensional system containing a non-scattering ring and the inverse problem is solved using the diffusion approximation to the transport equation.

  17. Radiation Dose to the Lens of the Eye from Computed Tomography Scans of the Head

    NASA Astrophysics Data System (ADS)

    Januzis, Natalie Ann

    While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient's medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods. The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data. The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult. First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion factors were derived for each scanner individually, but also were derived with the combined data from the two scanners as a means to investigate the feasibility of a scanner-independent method. Using the scanner-independent method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter, most of the fitted lens dose values fell within 10-15% of the measured values from the phantom study, suggesting that this is a fairly accurate method of estimating lens dose from the CTDIvol with knowledge of the patient's head size. Second, the dose reduction potential of organ-based tube current modulation (OB-TCM) and its effect on the CTDIvol-to-lens dose estimation method was investigated. The lens dose was measured with MOSFET dosimeters placed within the same six anthropomorphic phantoms. The phantoms were scanned with the five clinical head CT protocols with OB-TCM enabled on the one scanner model at our institution equipped with this software. The average decrease in lens dose with OB-TCM ranged from 13.5 to 26.0%. Using the size-specific method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter for protocols with OB-TCM, the majority of the fitted lens dose values fell within 15-18% of the measured values from the phantom study. Third, the effect of gantry angulation on lens dose was investigated by measuring the lens dose with TLDs placed within the six anthropomorphic phantoms. The 2-dimensional spatial distribution of dose within the areas of the phantoms containing the orbit was measured with radiochromic film. A method was derived to determine the CTDIvol-to-lens dose conversion factor based upon distance from the primary beam scan range to the lens. The average dose to the lens region decreased substantially for almost all the phantoms (ranging from 67 to 92%) when the orbit was exposed to scattered radiation compared to the primary beam. The effectiveness of this method to reduce lens dose is highly dependent upon the shape and size of the head, which influences whether or not the angled scan range coverage can include the entire brain volume and still avoid the orbit. The clinical component of this dissertation involved performing retrospective patient studies in the pediatric and adult populations, and reconstructing the lens doses from head CT examinations with the methods derived in the physics component. The cumulative lens doses in the patients selected for the retrospective study ranged from 40 to 1020 mGy in the pediatric group, and 53 to 2900 mGy in the adult group. This dissertation represents a comprehensive approach to lens of the eye dosimetry in CT imaging of the head. The collected data and derived formulas can be used in future studies on radiation-induced cataracts from repeated CT imaging of the head. Additionally, it can be used in the areas of personalized patient dose management, and protocol optimization and clinician training.

  18. On the evaluation of air mass factors for atmospheric near-ultraviolet and visible absorption spectroscopy

    NASA Technical Reports Server (NTRS)

    Perliski, Lori M.; Solomon, Susan

    1993-01-01

    The interpretation of UV-visible twilight absorption measurements of atmospheric chemical constituents is dependent on how well the optical path, or air mass factor, of light collected by the spectrometer is understood. A simple single scattering model and a Monte Carlo radiative transfer scheme have been developed to study the effects of multiple scattering, aerosol scattering, surface albedo and refraction on air mass factors for scattered light observations. At fairly short visible wavelengths (less than about 450 nm), stratospheric air mass factors are found to be relatively insensitive to multiple scattering, surface albedo and refraction, as well as aerosol scattering by background aerosols. Longer wavelengths display greater sensitivity to refraction and aerosol scattering. Tropospheric air mass factors are found to be highly dependent on aerosol scattering, surface albedo and, at long visible wavelengths (about 650 nm), refraction. Absorption measurements of NO2 and O4 are shown to support these conclusions.

  19. Rapid decrease of radar cross section of meteor head echo observed by the MU radar

    NASA Astrophysics Data System (ADS)

    Nakamura, T.; Nishio, M.; Sato, T.; Tsutsumi, S.; Tsuda, T.; Fushimi, K.

    The meteor head echo observation using the MU (Middle and Upper atmosphere) radar (46.5M Hz, 1MW), Shigaraki, Japan, was carried out simultaneously with a high sensitive ICCD (Image-intensified CCD) camera observation in November 2001. The time records were synchronized using GPS satellite signals, in order to compare instantaneous radar and optical meteor magnitudes. 26 faint meteors were successfully observed simultaneously by both equipments. Detailed comparison of the time variation of radar echo intensity and absolute optical magnitude showed that the radar scattering cross section is likely to decrease rapidly by 5 - 20 dB without no corresponding magnitude variation in the optical data. From a simple modeling, we concluded that such decrease of RCS (radar cross section ) is probably due to the transition from overdense head echo to underd ense head echo.

  20. Testing near-infrared spectrophotometry using a liquid neonatal head phantom

    NASA Astrophysics Data System (ADS)

    Wolf, Martin; Baenziger, Oskar; Keel, Matthias; Dietz, Vera; von Siebenthal, Kurt; Bucher, Hans U.

    1998-12-01

    We constructed a liquid phantom, which mimics the neonatal head for testing near infrared spectrophotometry instruments. It consists of a spherical, 3.5 mm thick layer of silicone rubber simulating skin and bone and acts as container for a liquid solution with IntralipidTM, 60 micrometers ol/l haemoglobin and yeast. The IntralipidTM concentration was varied to test the influence of scattering on haemoglobin concentrations and tissue oxygenation determined by the Critikon 2020. The solution was oxygenated using pure oxygen and then deoxygenated by the yeast. For the instruments algorithm, we found with increasing scattering (0.5%, 1%, 1.5% and 2% IntralipidTM concentration) an increasing offset added to the oxy- (56.7, 90.8, 112.5, 145.2 micrometers ol/l respectively) and deoxyhaemoglobin (25.4, 44.3, 58.5, 65.9 micrometers ol/l) concentration causing a decreasing range (41.3, 31.3, 25.0, 22.2%) of the tissue oxygen saturation reading. However, concentration changes were quantified correctly independently of the scattering level. For an other algorithm based on the analytical solution the offsets were smaller: oxyhaemoglobin 12.2, 34.0, 53.2, 88.8 micrometers ol/l and deoxyhaemoglobin 1.6, 11.2, 22.2, 28.1 micrometers ol/l. The range of the tissue oxygen saturation reading was higher: 71.3, 55.5, 45.7, 39.4%. However, concentration changes were not quantified correctly and depended on scattering. This study demonstrates the need to develop algorithms, which take into consideration the anatomical structures.

  1. SU-F-J-48: Effect of Scan Length On Magnitude of Imaging Dose in KV CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deshpande, S; Naidu, S; Sutar, A

    Purpose: To study effect of scan length on magnitude of imaging dose deposition in Varian kV CBCT for head & neck and pelvis CBCT. Methods: To study effect of scan length we measured imaging dose at depth of 8 cm for head and neck Cone Beam Computed Tomography (CBCT) acquisition ( X ray beam energy is used 100kV and 200 degree of gantry rotation) and at 16 cm depth for pelvis CBCT acquisition ( X ray beam energy used is 125 kV and 360 degree of gantry rotation) in specially designed phantom. We used farmer chamber which was calibrated inmore » kV X ray range for measurements .Dose was measured with default field size, and reducing field size along y direction to 10 cm and 5 cm. Results: As the energy of the beam decreases the scattered radiation increases and this contributes significantly to the dose deposited in the patient. By reducing the scan length to 10 Cm from default 20.6 cm we found a dose reduction of 14% for head and neck CBCT protocol and a reduction of 26% for pelvis CBCT protocol. Similarly for a scan length of 5cm compared to default the dose reduction in head and neck CBCT protocol is 36% while in the pelvis CBCT protocol the dose reduction is 50%. Conclusion: By limiting the scan length we can control the scatter radiation generated and hence the dose to the patient. However the variation in dose reduction for same length used in two protocols is because of the scan geometry. The pelvis CBCT protocol uses a full rotation and head and neck CBCT protocol uses partial rotation.« less

  2. Dosimetric evaluation of the effect of dental implants in head and neck radiotherapy.

    PubMed

    Ozen, Julide; Dirican, Bahar; Oysul, Kaan; Beyzadeoglu, Murat; Ucok, Ozlem; Beydemir, Bedri

    2005-06-01

    The aim of the study was to examine the dose enhancement from scattered radiation at bone-dental implant interfaces during simulated head and neck radiotherapy. Four cylindrical titanium dental implants with 3 different sizes and lengths were implanted into a human mandible in 4 different positions. Ionization measurements for 6 MV X, 25 MV X, and Co-60 gamma rays were done. Thermoluminescent dosimeter (TLD 100 ) chips were used to measure radiation dose enhancement due to the scattered electrons from titanium and electronic disequilibrium at the tissue-metal interface. The results showed that for Co-60, there is a 21% maximum increase in dose to alveolar mandibular bone at the close proximity to the titanium. For 6-MV x-rays the dose enhancement increase was almost the same or slightly lower than for Co-60, while for 25-MV high-energy x-rays, dose enhancement was lower than that of others. This increase in dose enhancement fell off rapidly and became insignificant at 2 mm from the interface. Total dose that may lead to osteoradionecrosis risk of the mandible is slightly but not significantly affected by the scattered dose of the dental implants of lower jaw in the radiation field exposed to 3 different radiation beams.

  3. Probing the microscopic corrugation of liquid surfaces with gas-liquid collisions

    NASA Technical Reports Server (NTRS)

    King, Mackenzie E.; Nathanson, Gilbert M.; Hanning-Lee, Mark A.; Minton, Timothy K.

    1993-01-01

    We have measured the directions and velocities of Ne, Ar, and Xe atoms scattering from perfluorinated ether and hydrocarbon liquids to probe the relationship between the microscopic roughness of liquid surfaces and gas-liquid collision dynamics. Impulsive energy transfer is governed by the angle of deflection: head-on encounters deposit more energy than grazing collisions. Many atoms scatter in the forward direction, particularly at glancing incidence. These results imply that the incoming atoms recoil locally from protruding C-H and C-F groups in hard spherelike collisions.

  4. Bayesian estimation of optical properties of the human head via 3D structural MRI

    NASA Astrophysics Data System (ADS)

    Barnett, Alexander H.; Culver, Joseph P.; Sorensen, A. Gregory; Dale, Anders M.; Boas, David A.

    2003-10-01

    Knowledge of the baseline optical properties of the tissues of the human head is essential for absolute cerebral oximetry, and for quantitative studies of brain activation. In this work we numerically model the utility of signals from a small 6-optode time-resolved diffuse optical tomographic apparatus for inferring baseline scattering and absorption coefficients of the scalp, skull and brain, when complete geometric information is available from magnetic resonance imaging (MRI). We use an optical model where MRI-segmented tissues are assumed homogeneous. We introduce a noise model capturing both photon shot noise and forward model numerical accuracy, and use Bayesian inference to predict errorbars and correlations on the measurments. We also sample from the full posterior distribution using Markov chain Monte Carlo. We conclude that ~ 106 detected photons are sufficient to measure the brain"s scattering and absorption to a few percent. We present preliminary results using a fast multi-layer slab model, comparing the case when layer thicknesses are known versus unknown.

  5. Altered sensory-motor control of the head as an etiological factor in space-motion sickness

    NASA Technical Reports Server (NTRS)

    Lackner, J. R.; DiZio, P.

    1989-01-01

    Mechanical unloading during head movements in weightlessness may be an etiological factor in space-motion sickness. We simulated altered head loading on Earth without affecting vestibular stimulation by having subjects wear a weighted helmet. Eight subjects were exposed to constant velocity rotation about a vertical axis with direction reversals every 60 sec. for eight reversals with the head loaded and eight with the head unloaded. The severity of motion sickness elicited was significantly higher when the head was loaded. This suggests that altered sensory-motor control of the head is also an etiological factor in space-motion sickness.

  6. Determination of the average orientation of DNA in the octopus sperm [ital Eledone] [ital cirrhossa] through polarized light scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, D.B.; Maestre, M.F.; McClain, W.M.

    1994-08-20

    The coupled-dipole approximation has been used to model polarized light-scattering data obtained from the sperm of the octopus [ital Eledone] [ital cirrhosa]. Mueller scattering-matrix elements (which describe how a sample alters the intensity and degree of polarization of scattered light) were measured as a function of angle. The sample was modeled as a helical fiber believed to correspond to a DNA protein complex. It was necessary to propose an inherent anisotropy in the polarizability of the fiber in order to fit the data. The direction of the principle axes of the polarizability were determined by comparing the model with experimentalmore » data. The results suggest that the 2-nm DNA fibers are perpendicular to the thick fiber that defines the helical geometry of the octopus sperm head.« less

  7. Predicting scattering scanning near-field optical microscopy of mass-produced plasmonic devices

    NASA Astrophysics Data System (ADS)

    Otto, Lauren M.; Burgos, Stanley P.; Staffaroni, Matteo; Ren, Shen; Süzer, Özgün; Stipe, Barry C.; Ashby, Paul D.; Hammack, Aeron T.

    2018-05-01

    Scattering scanning near-field optical microscopy enables optical imaging and characterization of plasmonic devices with nanometer-scale resolution well below the diffraction limit. This technique enables developers to probe and understand the waveguide-coupled plasmonic antenna in as-fabricated heat-assisted magnetic recording heads. In order to validate and predict results and to extract information from experimental measurements that is physically comparable to simulations, a model was developed to translate the simulated electric field into expected near-field measurements using physical parameters specific to scattering scanning near-field optical microscopy physics. The methods used in this paper prove that scattering scanning near-field optical microscopy can be used to determine critical sub-diffraction-limited dimensions of optical field confinement, which is a crucial metrology requirement for the future of nano-optics, semiconductor photonic devices, and biological sensing where the near-field character of light is fundamental to device operation.

  8. Changes in reflectance anisotropy of wheat crop during different phenophases

    NASA Astrophysics Data System (ADS)

    Lunagaria, Manoj M.; Patel, Haridas R.

    2017-04-01

    The canopy structure of wheat changes significantly with growth stages and leads to changes in reflectance anisotropy. Bidirectional reflectance distribution function characterises the reflectance anisotropy of the targets, which can be approximated. Spectrodirectional reflectance measurements on wheat crop were acquired using a field goniometer system. The bidirectional reflectance spectra were acquired at 54 view angles to cover the hemispheric span up to 60° view zenith. The observations were made during early growth stages till maturity of the crop. The anisotropy was not constant for all wavelengths and anisotropic factors clearly revealed spectral dependence, which was more pronounced in near principal plane. In near infrared, wheat canopy expressed less reflectance anisotropy because of higher multiple scattering. The broad hotspot signature was noticeable in reflectance of canopy whenever view and solar angles were close. Distinct changes in bidirectional reflectance distribution function were observed during booting to flowering stages as the canopy achieves more uniformity, height and head emergence. The function clearly reveals bowl shape during heading to early milking growth stages of the crop. Late growth stages show less prominent gap and shadow effects. Anisotropy index revealed that wheat exhibits changes in reflectance anisotropy with phenological development and with spectral bands.

  9. Spherical harmonics analysis of surface density fluctuations of spherical ionic SDS and nonionic C12E8 micelles: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Yoshii, Noriyuki; Nimura, Yuki; Fujimoto, Kazushi; Okazaki, Susumu

    2017-07-01

    The surface structure and its fluctuation of spherical micelles were investigated using a series of density correlation functions newly defined by spherical harmonics and Legendre polynomials based on the molecular dynamics calculations. To investigate the influence of head-group charges on the micelle surface structure, ionic sodium dodecyl sulfate and nonionic octaethyleneglycol monododecylether (C12E8) micelles were investigated as model systems. Large-scale density fluctuations were observed for both micelles in the calculated surface static structure factor. The area compressibility of the micelle surface evaluated by the surface static structure factor was tens-of-times larger than a typical value of a lipid membrane surface. The structural relaxation time, which was evaluated from the surface intermediate scattering function, indicates that the relaxation mechanism of the long-range surface structure can be well described by the hydrostatic approximation. The density fluctuation on the two-dimensional micelle surface has similar characteristics to that of three-dimensional fluids near the critical point.

  10. Spherical harmonics analysis of surface density fluctuations of spherical ionic SDS and nonionic C12E8 micelles: A molecular dynamics study.

    PubMed

    Yoshii, Noriyuki; Nimura, Yuki; Fujimoto, Kazushi; Okazaki, Susumu

    2017-07-21

    The surface structure and its fluctuation of spherical micelles were investigated using a series of density correlation functions newly defined by spherical harmonics and Legendre polynomials based on the molecular dynamics calculations. To investigate the influence of head-group charges on the micelle surface structure, ionic sodium dodecyl sulfate and nonionic octaethyleneglycol monododecylether (C 12 E 8 ) micelles were investigated as model systems. Large-scale density fluctuations were observed for both micelles in the calculated surface static structure factor. The area compressibility of the micelle surface evaluated by the surface static structure factor was tens-of-times larger than a typical value of a lipid membrane surface. The structural relaxation time, which was evaluated from the surface intermediate scattering function, indicates that the relaxation mechanism of the long-range surface structure can be well described by the hydrostatic approximation. The density fluctuation on the two-dimensional micelle surface has similar characteristics to that of three-dimensional fluids near the critical point.

  11. Debye-Waller Factor in Neutron Scattering by Ferromagnetic Metals

    NASA Astrophysics Data System (ADS)

    Paradezhenko, G. V.; Melnikov, N. B.; Reser, B. I.

    2018-04-01

    We obtain an expression for the neutron scattering cross section in the case of an arbitrary interaction of the neutron with the crystal. We give a concise, simple derivation of the Debye-Waller factor as a function of the scattering vector and the temperature. For ferromagnetic metals above the Curie temperature, we estimate the Debye-Waller factor in the range of scattering vectors characteristic of polarized magnetic neutron scattering experiments. In the example of iron, we compare the results of harmonic and anharmonic approximations.

  12. Evaluation of electron mobility in InSb quantum wells by means of percentage-impact

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mishima, T. D.; Edirisooriya, M.; Santos, M. B.

    2014-05-15

    In order to quantitatively analyze the contribution of each scattering factor toward the total carrier mobility, we use a new convenient figure-of-merit, named a percentage impact. The mobility limit due to a scattering factor, which is widely used to summarize a scattering analysis, has its own advantage. However, a mobility limit is not quite appropriate for the above purpose. A comprehensive understanding of the difference in contribution among many scattering factors toward the total carrier mobility can be obtained by evaluating percentage impacts of scattering factors, which can be straightforwardly calculated from their mobility limits and the total mobility. Ourmore » percentage impact analysis shows that threading dislocation is one of the dominant scattering factors for the electron transport in InSb quantum wells at room temperature.« less

  13. California oaks: a bibliography

    Treesearch

    James R. Griffin; Philip M. McDonald; Pamela C. Muick

    1987-01-01

    Among natural resource professionals, California oaks continue to attract considerable attention. This report provides a comprehensive bibliography of the extensive but scattered oak literature. The 768 references are organized into two systems: (a) a topical outline, in which references are displayed under key word headings and subheadings, and author-date entries...

  14. Whole-head functional brain imaging of neonates at cot-side using time-resolved diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Dempsey, Laura A.; Cooper, Robert J.; Powell, Samuel; Edwards, Andrea; Lee, Chuen-Wai; Brigadoi, Sabrina; Everdell, Nick; Arridge, Simon; Gibson, Adam P.; Austin, Topun; Hebden, Jeremy C.

    2015-07-01

    We present a method for acquiring whole-head images of changes in blood volume and oxygenation from the infant brain at cot-side using time-resolved diffuse optical tomography (TR-DOT). At UCL, we have built a portable TR-DOT device, known as MONSTIR II, which is capable of obtaining a whole-head (1024 channels) image sequence in 75 seconds. Datatypes extracted from the temporal point spread functions acquired by the system allow us to determine changes in absorption and reduced scattering coefficients within the interrogated tissue. This information can then be used to define clinically relevant measures, such as oxygen saturation, as well as to reconstruct images of relative changes in tissue chromophore concentration, notably those of oxy- and deoxyhaemoglobin. Additionally, the effective temporal resolution of our system is improved with spatio-temporal regularisation implemented through a Kalman filtering approach, allowing us to image transient haemodynamic changes. By using this filtering technique with intensity and mean time-of-flight datatypes, we have reconstructed images of changes in absorption and reduced scattering coefficients in a dynamic 2D phantom. These results demonstrate that MONSTIR II is capable of resolving slow changes in tissue optical properties within volumes that are comparable to the preterm head. Following this verification study, we are progressing to imaging a 3D dynamic phantom as well as the neonatal brain at cot-side. Our current study involves scanning healthy babies to demonstrate the quality of recordings we are able to achieve in this challenging patient population, with the eventual goal of imaging functional activation and seizures.

  15. Quantitation of tumor uptake with molecular breast imaging.

    PubMed

    Bache, Steven T; Kappadath, S Cheenu

    2017-09-01

    We developed scatter and attenuation-correction techniques for quantifying images obtained with Molecular Breast Imaging (MBI) systems. To investigate scatter correction, energy spectra of a 99m Tc point source were acquired with 0-7-cm-thick acrylic to simulate scatter between the detector heads. System-specific scatter correction factor, k, was calculated as a function of thickness using a dual energy window technique. To investigate attenuation correction, a 7-cm-thick rectangular phantom containing 99m Tc-water simulating breast tissue and fillable spheres simulating tumors was imaged. Six spheres 10-27 mm in diameter were imaged with sphere-to-background ratios (SBRs) of 3.5, 2.6, and 1.7 and located at depths of 0.5, 1.5, and 2.5 cm from the center of the water bath for 54 unique tumor scenarios (3 SBRs × 6 sphere sizes × 3 depths). Phantom images were also acquired in-air under scatter- and attenuation-free conditions, which provided ground truth counts. To estimate true counts, T, from each tumor, the geometric mean (GM) of the counts within a prescribed region of interest (ROI) from the two projection images was calculated as T=C1C2eμtF, where C are counts within the square ROI circumscribing each sphere on detectors 1 and 2, μ is the linear attenuation coefficient of water, t is detector separation, and the factor F accounts for background activity. Four unique F definitions-standard GM, background-subtraction GM, MIRD Primer 16 GM, and a novel "volumetric GM"-were investigated. Error in T was calculated as the percentage difference with respect to in-air. Quantitative accuracy using the different GM definitions was calculated as a function of SBR, depth, and sphere size. Sensitivity of quantitative accuracy to ROI size was investigated. We developed an MBI simulation to investigate the robustness of our corrections for various ellipsoidal tumor shapes and detector separations. Scatter correction factor k varied slightly (0.80-0.95) over a compressed breast thickness range of 6-9 cm. Corrected energy spectra recovered general characteristics of scatter-free spectra. Quantitatively, photopeak counts were recovered to <10% compared to in-air conditions after scatter correction. After GM attenuation correction, mean errors (95% confidence interval, CI) for all 54 imaging scenarios were 149% (-154% to +455%), -14.0% (-38.4% to +10.4%), 16.8% (-14.7% to +48.2%), and 2.0% (-14.3 to +18.3%) for the standard GM, background-subtraction GM, MIRD 16 GM, and volumetric GM, respectively. Volumetric GM was less sensitive to SBR and sphere size, while all GM methods were insensitive to sphere depth. Simulation results showed that Volumetric GM method produced a mean error within 5% over all compressed breast thicknesses (3-14 cm), and that the use of an estimated radius for nonspherical tumors increases the 95% CI to at most ±23%, compared with ±16% for spherical tumors. Using DEW scatter- and our Volumetric GM attenuation-correction methodology yielded accurate estimates of tumor counts in MBI over various tumor sizes, shapes, depths, background uptake, and compressed breast thicknesses. Accurate tumor uptake can be converted to radiotracer uptake concentration, allowing three patient-specific metrics to be calculated for quantifying absolute uptake and relative uptake change for assessment of treatment response. © 2017 American Association of Physicists in Medicine.

  16. Coherence factors in a high-tc cuprate probed by quasi-particle scattering off vortices.

    PubMed

    Hanaguri, T; Kohsaka, Y; Ono, M; Maltseva, M; Coleman, P; Yamada, I; Azuma, M; Takano, M; Ohishi, K; Takagi, H

    2009-02-13

    When electrons pair in a superconductor, quasi-particles develop an acute sensitivity to different types of scattering potential that is described by the appearance of coherence factors in the scattering amplitudes. Although the effects of coherence factors are well established in isotropic superconductors, they are much harder to detect in their anisotropic counterparts, such as high-superconducting-transition-temperature cuprates. We demonstrate an approach that highlights the momentum-dependent coherence factors in Ca2-xNaxCuO2Cl2. We used Fourier-transform scanning tunneling spectroscopy to reveal a magnetic-field dependence in quasi-particle scattering interference patterns that is sensitive to the sign of the anisotropic gap. This result is associated with the d-wave coherence factors and quasi-particle scattering off vortices. Our technique thus provides insights into the nature of electron pairing as well as quasi-particle scattering processes in unconventional superconductors.

  17. Signal Estimation, Inverse Scattering, and Problems in One and Two Dimensions.

    DTIC Science & Technology

    1982-11-01

    attention to implication for new estimation algorithms and signal processing and, to a lesser extent, for system theory . The publications resulting...from the work are listed by category and date. They are briefly organized and reviewed under five major headings: (1) Two-Dimensional System Theory ; (2

  18. Risk factors for work-related stress and health in head teachers.

    PubMed

    Phillips, Samantha J; Sen, Dil; McNamee, Roseanne

    2008-12-01

    Work-related stress (WRS) is known to cause ill-health and decreased productivity. Work in the education sector is thought to be particularly stressful. Few studies have considered risk factors for WRS and health in head teachers. To investigate health in head teachers in West Sussex. To determine personal risk factors most likely to predict cases of WRS and of poor health in head teachers. A cross-sectional study, in a population of 290 head teachers and principals of colleges of further education, using a validated questionnaire, 'a short stress evaluation tool' (ASSET) and additional questions derived from earlier studies. Results were compared with the ASSET database 'norm' groups: a general population of workers (GPN) group and a group of managers and professionals (MPN). 'Caseness' was defined as respondents who felt work was 'very or extremely stressful'. Head teachers had poor physical and mental health compared to the GPN group. Psychological well-being, particularly of females and primary head teachers was worse than a comparative group of managers and professionals. Teaching<5 h/week was a significant predictor of caseness and being female was the main risk factor for poor psychological well-being. Prevalence of self-reported stress in head teachers in West Sussex is high. Female head teachers had worse health outcomes. Our study identified possible personal risk factors predicting WRS and/or poor health in head teachers.

  19. Study of water diffusion on single-supported bilayer lipid membranes by quasielastic neutron scattering

    NASA Astrophysics Data System (ADS)

    Bai, M.; Miskowiec, A.; Hansen, F. Y.; Taub, H.; Jenkins, T.; Tyagi, M.; Diallo, S. O.; Mamontov, E.; Herwig, K. W.; Wang, S.-K.

    2012-05-01

    High-energy-resolution quasielastic neutron scattering has been used to elucidate the diffusion of water molecules in proximity to single bilayer lipid membranes supported on a silicon substrate. By varying sample temperature, level of hydration, and deuteration, we identify three different types of diffusive water motion: bulk-like, confined, and bound. The motion of bulk-like and confined water molecules is fast compared to those bound to the lipid head groups (7-10 H2O molecules per lipid), which move on the same nanosecond time scale as H atoms within the lipid molecules.

  20. Acute diabetes insipidus in severe head injury: a prospective study.

    PubMed

    Hadjizacharia, Pantelis; Beale, Elizabeth O; Inaba, Kenji; Chan, Linda S; Demetriades, Demetrios

    2008-10-01

    The incidence and risk factors for acute diabetes insipidus after severe head injury and the effect of this complication on outcomes have not been evaluated in any large prospective studies. We conducted a prospective study of all patients admitted to the surgical ICU of a Level I trauma center with severe head injury (head Abbreviated Injury Score [AIS] >or= 3). The following potential risk factors with p < 0.2 on bivariate analysis were included in a stepwise logistic regression to identify independent risk factors for diabetes insipidus and its association with mortality: age, mechanism of injury (blunt or penetrating), blood pressure, Glasgow Coma Scale, Injury Severity Score, head and other body area AIS, skull fracture, cerebral edema and shift, intracranial hemorrhage, and pneumocephaly. There were 436 patients (blunt injuries, 392; penetrating injuries, 44); 387 patients had isolated head injury. Diabetes insipidus occurred in 15.4% of all patients (blunt, 12.5%; penetrating, 40.9%; p < 0.0001) and in 14.7% of patients with isolated head injury (blunt, 11.8%; penetrating, 39.5%; p < 0.0001). The presence of major extracranial injuries did not influence the incidence of diabetes insipidus. Independent risk factors for diabetes insipidus in isolated head injury were Glasgow Coma Scale3. Diabetes insipidus was an independent risk factor for death (adjusted odds ratio, 3.96; 95% CI [1.65, 9.72]; adjusted p value = 0.002). The incidence of acute diabetes insipidus in severe head injury is high, especially in penetrating injuries. Independent risk factors for diabetes insipidus include a Glasgow Coma Scale3. Acute diabetes insipidus was associated with significantly increased mortality.

  1. Design and fabrication of a realistic anthropomorphic heterogeneous head phantom for MR purposes

    PubMed Central

    Wood, Sossena; Krishnamurthy, Narayanan; Santini, Tales; Raval, Shailesh; Farhat, Nadim; Holmes, John Andy; Ibrahim, Tamer S.

    2017-01-01

    Objective The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications. Materials and methods An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application that involves electromagnetic-tissue interactions: MRI (due to it being an available resource). The developed phantom was filled with media possessing electromagnetic constitutive parameters that correspond to biological tissues at ~297 MHz. A preliminary comparison between an in-vivo human volunteer (based on whom the anthropomorphic head phantom was created) and various phantoms types, one being the anthropomorphic heterogeneous head phantom, were performed using a 7 Tesla human MRI scanner. Results Echo planar imaging was performed and minimal ghosting and fluctuations were observed using the proposed anthropomorphic phantom. The magnetic field distributions (during MRI experiments at 7 Tesla) and the scattering parameter (measured using a network analyzer) were most comparable between the anthropomorphic heterogeneous head phantom and an in-vivo human volunteer. Conclusion The developed anthropomorphic heterogeneous head phantom can be used as a resource to various researchers in applications that involve electromagnetic-biological tissue interactions such as MRI. PMID:28806768

  2. Head, withers and pelvic movement asymmetry and their relative timing in trot in racing Thoroughbreds in training.

    PubMed

    Pfau, T; Noordwijk, K; Sepulveda Caviedes, M F; Persson-Sjodin, E; Barstow, A; Forbes, B; Rhodin, M

    2018-01-01

    Horses show compensatory head movement in hindlimb lameness and compensatory pelvis movement in forelimb lameness but little is known about the relationship of withers movement symmetry with head and pelvic asymmetry in horses with naturally occurring gait asymmetries. To document head, withers and pelvic movement asymmetry and timing differences in horses with naturally occurring gait asymmetries. Retrospective analysis of gait data. Head, withers and pelvic movement asymmetry and timing of displacement minima and maxima were quantified from inertial sensors in 163 Thoroughbreds during trot-ups on hard ground. Horses were divided into 4 subgroups using the direction of head and withers movement asymmetry. Scatter plots of head vs. pelvic movement asymmetry illustrated how the head-withers relationship distinguishes between contralateral and ipsilateral head-pelvic movement asymmetry. Independent t test or Mann-Whitney U test (P<0.05) compared pelvic movement asymmetry and timing differences between groups. The relationship between head and withers asymmetry (i.e. same sided or opposite sided asymmetry) predicts the relationship between head and pelvic asymmetry in 69-77% of horses. Pelvic movement symmetry was significantly different between horses with same sign vs. opposite sign of head-withers asymmetry (P<0.0001). Timing of the maximum head height reached after contralateral ('sound') stance was delayed compared to withers (P = 0.02) and pelvis (P = 0.04) in horses with contralateral head-withers asymmetry. The clinical lameness status of the horses was not investigated. In the Thoroughbreds with natural gait asymmetries investigated here, the direction of head vs. withers movement asymmetry identifies the majority of horses with ipsilateral and contralateral head and pelvic movement asymmetries. Withers movement should be further investigated for differentiating between forelimb and hindlimb lame horses. Horses with opposite sided head and withers asymmetry significantly delay the upward movement of the head after 'sound' forelimb stance. © 2017 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.

  3. Lessons from a tarantula: new insights into muscle thick filament and myosin interacting-heads motif structure and function.

    PubMed

    Alamo, Lorenzo; Koubassova, Natalia; Pinto, Antonio; Gillilan, Richard; Tsaturyan, Andrey; Padrón, Raúl

    2017-10-01

    The tarantula skeletal muscle X-ray diffraction pattern suggested that the myosin heads were helically arranged on the thick filaments. Electron microscopy (EM) of negatively stained relaxed tarantula thick filaments revealed four helices of heads allowing a helical 3D reconstruction. Due to its low resolution (5.0 nm), the unambiguous interpretation of densities of both heads was not possible. A resolution increase up to 2.5 nm, achieved by cryo-EM of frozen-hydrated relaxed thick filaments and an iterative helical real space reconstruction, allowed the resolving of both heads. The two heads, "free" and "blocked", formed an asymmetric structure named the "interacting-heads motif" (IHM) which explained relaxation by self-inhibition of both heads ATPases. This finding made tarantula an exemplar system for thick filament structure and function studies. Heads were shown to be released and disordered by Ca 2+ -activation through myosin regulatory light chain phosphorylation, leading to EM, small angle X-ray diffraction and scattering, and spectroscopic and biochemical studies of the IHM structure and function. The results from these studies have consequent implications for understanding and explaining myosin super-relaxed state and thick filament activation and regulation. A cooperative phosphorylation mechanism for activation in tarantula skeletal muscle, involving swaying constitutively Ser35 mono-phosphorylated free heads, explains super-relaxation, force potentiation and post-tetanic potentiation through Ser45 mono-phosphorylated blocked heads. Based on this mechanism, we propose a swaying-swinging, tilting crossbridge-sliding filament for tarantula muscle contraction.

  4. Commissioning and Validation of the First Monte Carlo Based Dose Calculation Algorithm Commercial Treatment Planning System in Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larraga-Gutierrez, J. M.; Garcia-Garduno, O. A.; Hernandez-Bojorquez, M.

    2010-12-07

    This work presents the beam data commissioning and dose calculation validation of the first Monte Carlo (MC) based treatment planning system (TPS) installed in Mexico. According to the manufacturer specifications, the beam data commissioning needed for this model includes: several in-air and water profiles, depth dose curves, head-scatter factors and output factors (6x6, 12x12, 18x18, 24x24, 42x42, 60x60, 80x80 and 100x100 mm{sup 2}). Radiographic and radiochromic films, diode and ionization chambers were used for data acquisition. MC dose calculations in a water phantom were used to validate the MC simulations using comparisons with measured data. Gamma index criteria 2%/2 mmmore » were used to evaluate the accuracy of MC calculations. MC calculated data show an excellent agreement for field sizes from 18x18 to 100x100 mm{sup 2}. Gamma analysis shows that in average, 95% and 100% of the data passes the gamma index criteria for these fields, respectively. For smaller fields (12x12 and 6x6 mm{sup 2}) only 92% of the data meet the criteria. Total scatter factors show a good agreement (<2.6%) between MC calculated and measured data, except for the smaller fields (12x12 and 6x6 mm{sup 2}) that show a error of 4.7%. MC dose calculations are accurate and precise for clinical treatment planning up to a field size of 18x18 mm{sup 2}. Special care must be taken for smaller fields.« less

  5. Designing Mixed Detergent Micelles for Uniform Neutron Contrast

    DOE PAGES

    Oliver, Ryan C.; Pingali, Sai Venkatesh; Urban, Volker S.

    2017-09-29

    Micelle-forming detergents provide an amphipathic environment that mimics lipid bilayers and are important tools used to solubilize and stabilize membrane proteins in solution for in vitro structural investigations. Small-angle neutron scattering (SANS) performed at the neutron contrast match point of detergent molecules allows observing the scattering signal from membrane proteins unobstructed by contributions from the detergent. However, we show here that even for a perfectly average-contrast matched detergent there arises significant core-shell scattering from the contrast difference between aliphatic detergent tails and hydrophilic head groups. This residual signal at the average detergent contrast match point interferes with interpreting structural datamore » of membrane proteins. This complication is often made worse by the presence of excess empty (protein-free) micelles. Here, we present an approach for the rational design of mixed micelles containing a deuterated detergent analog, which eliminates neutron contrast between core and shell, and allows the micelle scattering to be fully contrast matched to unambiguously resolve membrane protein structure using solution SANS.« less

  6. Designing Mixed Detergent Micelles for Uniform Neutron Contrast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliver, Ryan C.; Pingali, Sai Venkatesh; Urban, Volker S.

    Micelle-forming detergents provide an amphipathic environment that mimics lipid bilayers and are important tools used to solubilize and stabilize membrane proteins in solution for in vitro structural investigations. Small-angle neutron scattering (SANS) performed at the neutron contrast match point of detergent molecules allows observing the scattering signal from membrane proteins unobstructed by contributions from the detergent. However, we show here that even for a perfectly average-contrast matched detergent there arises significant core-shell scattering from the contrast difference between aliphatic detergent tails and hydrophilic head groups. This residual signal at the average detergent contrast match point interferes with interpreting structural datamore » of membrane proteins. This complication is often made worse by the presence of excess empty (protein-free) micelles. Here, we present an approach for the rational design of mixed micelles containing a deuterated detergent analog, which eliminates neutron contrast between core and shell, and allows the micelle scattering to be fully contrast matched to unambiguously resolve membrane protein structure using solution SANS.« less

  7. Real-time particulate mass measurement based on laser scattering

    NASA Astrophysics Data System (ADS)

    Rentz, Julia H.; Mansur, David; Vaillancourt, Robert; Schundler, Elizabeth; Evans, Thomas

    2005-11-01

    OPTRA has developed a new approach to the determination of particulate size distribution from a measured, composite, laser angular scatter pattern. Drawing from the field of infrared spectroscopy, OPTRA has employed a multicomponent analysis technique which uniquely recognizes patterns associated with each particle size "bin" over a broad range of sizes. The technique is particularly appropriate for overlapping patterns where large signals are potentially obscuring weak ones. OPTRA has also investigated a method for accurately training the algorithms without the use of representative particles for any given application. This streamlined calibration applies a one-time measured "instrument function" to theoretical Mie patterns to create the training data for the algorithms. OPTRA has demonstrated this algorithmic technique on a compact, rugged, laser scatter sensor head we developed for gas turbine engine emissions measurements. The sensor contains a miniature violet solid state laser and an array of silicon photodiodes, both of which are commercial off the shelf. The algorithmic technique can also be used with any commercially available laser scatter system.

  8. Near-infrared spectroscopy of the adult head: effect of scattering and absorbing obstructions in the cerebrospinal fluid layer on light distribution in the tissue.

    PubMed

    Dehghani, H; Delpy, D T

    2000-09-01

    Previous modeling of near-infrared (NIR) light distribution in models of the adult head incorporating a clear nonscattering cerebrospinal fluid (CSF) layer have shown the latter to have a profound effect on the resulting photon measurement density function (PMDF). In particular, the presence of the CSF limits the PMDF largely to the outer cortical gray matter with little signal contribution from the deeper white matter. In practice, the CSF is not a simple unobstructed clear layer but contains light-scattering membranes and is crossed by various blood vessels. Using a radiosity-diffusion finite-element model, we investigated the effect on the PMDF of introducing intrusions within the clear layer. The results show that the presence of such obstructions does not significantly increase the light penetration into the brain tissue, except immediately adjacent to the obstruction and that its presence also increases the light sampling of the adjacent skull tissues, which would lead to additional contamination of the NIR spectroscopy signal by the surface tissue layers.

  9. Risk factors for closed-head injuries during military airborne operations.

    PubMed

    Knapik, Joseph J; Steelman, Ryan; Hoedebecke, Kyle; Klug, Kevin L; Rankin, Shawn; Proctor, Stanley; Graham, Bria; Jones, Bruce H

    2014-02-01

    One of the more serious adverse outcomes of military airborne operations is closed-head injuries. This investigation examined risk factors for closed-head injuries in an Army airborne infantry unit. Closed-head injuries were defined as energy exchanges in which the head contacted the ground or an object and the soldier sought medical care for external trauma, headache, loss of consciousness, or altered mental state. Injury data were obtained by investigators in the drop zone and diagnoses were confirmed by a physician. Operational data on potential injury risk factors were obtained from routine reports published by the infantry unit. Weather data were obtained using a pocket weather tracker. There were 96,132 jumps resulting in 310 closed-head injuries for a crude incidence of 3.22/1000 jumps. In 98% of known cases the injury was associated with parachute landings. Multivariate logistic regression revealed that independent risk factors for closed-head injuries included night jumps, combat loads, higher wind speeds, higher temperatures, enlisted rank, and entanglements. This study identifies the current incidence and extrinsic risk factors for closed-head injuries during military airborne operations. Although it is necessary to conduct airborne training under realistic conditions, trainers and commanders should be aware of these risks and plan airborne operations accordingly.

  10. An improved optical scheme for self-mixing low-coherence flowmeters

    NASA Astrophysics Data System (ADS)

    Di Cecilia, Luca; Rovati, Luigi; Cattini, Stefano

    2017-02-01

    In this paper we present a fiber-based low-coherence self-mixing interferometer exploiting a single-arm approach to measure the flow in a pipe. The main advantages of the proposed system are the flexibility offered by fiber-connected optical head, a greater ease of alignment, the rejection of "common-mode" vibrations, and greater stability. Thanks to the use of a low-coherence source, the proposed system investigates the velocity of the scattering particles owing only in a fixed and well defined region located close to the duct wall itself. The reported experimental results demonstrate that in laminar flow regime the developed system is able to determine the flow and it is quite robust to variation in the scatterers concentration. Increasing the scatterers concentration of about 24 times, the sensitivity S has reduced of less than 30%.

  11. Quantitative analysis of transcranial and intraparenchymal light penetration in human cadaver brain tissue.

    PubMed

    Tedford, Clark E; DeLapp, Scott; Jacques, Steven; Anders, Juanita

    2015-04-01

    Photobiomodulation (PBM) also known as low-level light therapy has been used successfully for the treatment of injury and disease of the nervous system. The use of PBM to treat injury and diseases of the brain requires an in-depth understanding of light propagation through tissues including scalp, skull, meninges, and brain. This study investigated the light penetration gradients in the human cadaver brain using a Transcranial Laser System with a 30 mm diameter beam of 808 nm wavelength light. In addition, the wavelength-dependence of light scatter and absorbance in intraparenchymal brain tissue using 660, 808, and 940 nm wavelengths was investigated. Intact human cadaver heads (n = 8) were obtained for measurement of light propagation through the scalp/skull/meninges and into brain tissue. The cadaver heads were sectioned in either the transverse or mid-sagittal. The sectioned head was mounted into a cranial fixture with an 808 nm wavelength laser system illuminating the head from beneath with either pulsed-wave (PW) or continuous-wave (CW) laser light. A linear array of nine isotropic optical fibers on a 5 mm pitch was inserted into the brain tissue along the optical axis of the beam. Light collected from each fiber was delivered to a multichannel power meter. As the array was lowered into the tissue, the power from each probe was recorded at 5 mm increments until the inner aspect of the dura mater was reached. Intraparenchymal light penetration measurements were made by delivering a series of wavelengths (660, 808, and 940 nm) through a separate optical fiber within the array, which was offset from the array line by 5 mm. Local light penetration was determined and compared across the selected wavelengths. Unfixed cadaver brains provide good anatomical localization and reliable measurements of light scatter and penetration in the CNS tissues. Transcranial application of 808 nm wavelength light penetrated the scalp, skull, meninges, and brain to a depth of approximately 40 mm with an effective attenuation coefficient for the system of 2.22 cm(-1) . No differences were observed in the results between the PW and CW laser light. The intraparenchymal studies demonstrated less absorption and scattering for the 808 nm wavelength light compared to the 660 or 940 nm wavelengths. Transcranial light measurements of unfixed human cadaver brains allowed for determinations of light penetration variables. While unfixed human cadaver studies do not reflect all the conditions seen in the living condition, comparisons of light scatter and penetration and estimates of fluence levels can be used to establish further clinical dosing. The 808 nm wavelength light demonstrated superior CNS tissue penetration. © 2015 Wiley Periodicals, Inc.

  12. A GRAVITATIONAL DOUBLE-SCATTERING MECHANISM FOR GENERATING HIGH-VELOCITY OBJECTS DURING HALO MERGERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samsing, Johan; Department of Astrophysical Sciences, Princeton University, Peyton Hall, Princeton, NJ 08544

    2015-02-01

    We present a dynamical model that describes how halo particles can receive a significant energy kick from the merger between their own host halo and a target halo. This could provide a possible explanation for some high-velocity objects, including extended systems like globular clusters (GCs). In the model we especially introduce a double-scattering mechanism, where a halo particle receives a significant part of its total energy kick by first undergoing a gravitational deflection by the target halo and subsequently by its original host halo. This generates an energy kick that is due to the relative velocity between the halos duringmore » the deflections. We derive analytically the total kick energy of the particle, which is composed of energy from the double-scattering mechanism and tidal fields, as a function of its position in its original host halo just before merger. In the case of a 1:10 merger, we find that the presented mechanisms can easily generate particles with a velocity approximately two times the virial velocity of the target halo. This motivates us to suggest that the high velocity of the recently discovered GC HVGC-1 can be explained by a head-on halo merger. Finally, we illustrate the orbital evolution of high-velocity particles outside the virial sphere of the target halo by solving the equation of motion in an expanding universe. We find a sweet spot around a scale factor of 0.3-0.5 for ejecting particles into large orbits, which can easily reach beyond approximately five virial radii.« less

  13. Personality change following head injury: assessment with the NEO Five-Factor Inventory.

    PubMed

    Lannoo, E; de Deyne, C; Colardyn, F; de Soete, G; Jannes, C

    1997-11-01

    We evaluated personality change following head injury in 68 patients at 6 months postinjury using the NEO Five-Factor Inventory to assess the five personality dimensions of the Five-Factor Model of Personality. All items had to be rated twice, once for the preinjury and once for the current status. Twenty-eight trauma patients with injuries to other parts of the body than the head were used as controls. For the head-injured group, 63 relatives also completed the questionnaire. The results showed no differences between the ratings of head-injured patients and the ratings of trauma control patients. Both groups showed significant change in the personality dimensions Neuroticism, Extraversion, and Conscientiousness. Compared to their relatives, head-injured patients report a smaller change in Extraversion and Conscientiousness. Changes were not reported on the Openness and Agreeableness scales, by neither the head-injured or their relatives, nor by the trauma controls.

  14. Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bootsma, G. J., E-mail: Gregory.Bootsma@rmp.uhn.on.ca; Verhaegen, F.; Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec H3G 1A4

    2015-01-15

    Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithmmore » which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.« less

  15. Characterization of Optical Properties of Desert Dust and Other Aerosols Using Postive Matrix Factorization

    NASA Astrophysics Data System (ADS)

    Lihavainen, H.; Alghamdi, M.; Hyvärinen, A.; Hussein, T.; Neitola, K.; Khoder, M.; Abdelmaksoud, A. S.; Al-Jeelani, H.; Shabbaj, I. I.; Almehmadi, F. M.

    2017-12-01

    To derive the comprehensive aerosol in situ characteristics at a rural background area in Saudi Arabia, an aerosol measurements station was established to Hada Al Sham, 60 km east from the Red Sea and the city of Jeddah. The present sturdy describes the observational data from February 2013 to February 2015 of scattering and absorption coefficients, Ångström exponents and single scattering albedo over the measurement period. As expected, the scattering coefficient was dominated by large desert dust particles with low Ångström scattering exponent. Especially from February to June the Ångström scattering exponent was clearly lower and scattering coefficients higher than total averages because of the dust outbreak season. Aerosol optical properties had clear diurnal cycle. The lowest scattering and absorption coefficients and aerosol optical depths were observed around noon. The observed diurnal variation is caused by wind direction and speed, during night time very calm easterly winds are dominating whereas during daytime the stronger westerly winds are dominating (sea breeze). Positive Matrix Factorization mathematical tool was applied to the scattering and absorption coefficients and PM2.5 and coarse mode (PM10- PM2.5) mass concentrations to characterise aerosols from different sources. Analysis revealed three clearly different types of sources, anthropogenic, BC source and desert dust. These factors have clearly different seasonal and diurnal variation. The contribution of desert dust factor was dominating from February to May, whereas the contribution of anthropogenic factor is quite steady over the whole year. We estimated the mass absorption and scattering efficiencies for the factors and they agreed well with earlier observations. Hence, this method could be used to distinguish aerosol source characteristics, at least in fairly simple cases.

  16. Mild traumatic brain injury: a risk factor for neurodegeneration

    PubMed Central

    2010-01-01

    Recently, it has become clear that head trauma can lead to a progressive neurodegeneration known as chronic traumatic encephalopathy. Although the medical literature also implicates head trauma as a risk factor for Alzheimer's disease, these findings are predominantly based on clinical diagnostic criteria that lack specificity. The dementia that follows head injuries or repetitive mild trauma may be caused by chronic traumatic encephalopathy, alone or in conjunction with other neurodegenerations (for example, Alzheimer's disease). Prospective longitudinal studies of head-injured individuals, with neuropathological verification, will not only improve understanding of head trauma as a risk factor for dementia but will also enhance treatment and prevention of a variety of neurodegenerative diseases. PMID:20587081

  17. An investigation of light transport through scattering bodies with non-scattering regions.

    PubMed

    Firbank, M; Arridge, S R; Schweiger, M; Delpy, D T

    1996-04-01

    Near-infra-red (NIR) spectroscopy is increasingly being used for monitoring cerebral oxygenation and haemodynamics. One current concern is the effect of the clear cerebrospinal fluid upon the distribution of light in the head. There are difficulties in modelling clear layers in scattering systems. The Monte Carlo model should handle clear regions accurately, but is too slow to be used for realistic geometries. The diffusion equation can be solved quickly for realistic geometries, but is only valid in scattering regions. In this paper we describe experiments carried out on a solid slab phantom to investigate the effect of clear regions. The experimental results were compared with the different models of light propagation. We found that the presence of a clear layer had a significant effect upon the light distribution, which was modelled correctly by Monte Carlo techniques, but not by diffusion theory. A novel approach to calculating the light transport was developed, using diffusion theory to analyze the scattering regions combined with a radiosity approach to analyze the propagation through the clear region. Results from this approach were found to agree with both the Monte Carlo and experimental data.

  18. Flying Drosophilamelanogaster maintain arbitrary but stable headings relative to the angle of polarized light.

    PubMed

    Warren, Timothy L; Weir, Peter T; Dickinson, Michael H

    2018-05-11

    Animals must use external cues to maintain a straight course over long distances. In this study, we investigated how the fruit fly Drosophila melanogaster selects and maintains a flight heading relative to the axis of linearly polarized light, a visual cue produced by the atmospheric scattering of sunlight. To track flies' headings over extended periods, we used a flight simulator that coupled the angular velocity of dorsally presented polarized light to the stroke amplitude difference of the animals' wings. In the simulator, most flies actively maintained a stable heading relative to the axis of polarized light for the duration of 15 min flights. We found that individuals selected arbitrary, unpredictable headings relative to the polarization axis, which demonstrates that D . melanogaster can perform proportional navigation using a polarized light pattern. When flies flew in two consecutive bouts separated by a 5 min gap, the two flight headings were correlated, suggesting individuals retain a memory of their chosen heading. We found that adding a polarized light pattern to a light intensity gradient enhanced flies' orientation ability, suggesting D . melanogaster use a combination of cues to navigate. For both polarized light and intensity cues, flies' capacity to maintain a stable heading gradually increased over several minutes from the onset of flight. Our findings are consistent with a model in which each individual initially orients haphazardly but then settles on a heading which is maintained via a self-reinforcing process. This may be a general dispersal strategy for animals with no target destination. © 2018. Published by The Company of Biologists Ltd.

  19. Validation of a Custom Instrumented Retainer Form Factor for Measuring Linear and Angular Head Impact Kinematics.

    PubMed

    Miller, Logan E; Kuo, Calvin; Wu, Lyndia C; Urban, Jillian E; Camarillo, David B; Stitzel, Joel D

    2018-05-01

    Head impact exposure in popular contact sports is not well understood, especially in the youth population, despite recent advances in impact-sensing technology which has allowed widespread collection of real-time head impact data. Previous studies indicate that a custom-instrumented mouthpiece is a superior method for collecting accurate head acceleration data. The objective of this study was to evaluate the efficacy of mounting a sensor device inside an acrylic retainer form factor to measure six-degrees-of-freedom (6DOF) head kinematic response. This study compares 6DOF mouthpiece kinematics at the head center of gravity (CG) to kinematics measured by an anthropomorphic test device (ATD). This study found that when instrumentation is mounted in the rigid retainer form factor, there is good coupling with the upper dentition and highly accurate kinematic results compared to the ATD. Peak head kinematics were correlated with r2 > 0.98 for both rotational velocity and linear acceleration and r2 = 0.93 for rotational acceleration. These results indicate that a rigid retainer-based form factor is an accurate and promising method of collecting head impact data. This device can be used to study head impacts in helmeted contact sports such as football, hockey, and lacrosse as well as nonhelmeted sports such as soccer and basketball. Understanding the magnitude and frequency of impacts sustained in various sports using an accurate head impact sensor, such as the one presented in this study, will improve our understanding of head impact exposure and sports-related concussion.

  20. Simulation and analysis on ultrasonic testing for the cement grouting defects of the corrugated pipe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qingbang, Han; Ling, Chen; Changping, Zhu

    2014-02-18

    The defects exist in the cement grouting process of prestressed corrugated pipe may directly impair the bridge safety. In this paper, sound fields propagation in concrete structures with corrugated pipes and the influence of various different defects are simulated and analyzed using finite element method. The simulation results demonstrate a much complex propagation characteristic due to multiple reflection, refraction and scattering, where the scattering signals caused by metal are very strong, while the signals scattered by an air bubble are weaker. The influence of defect both in time and frequency domain are found through deconvolution treatment. In the time domain,more » the deconvolution signals correspond to larger defect display a larger head wave amplitude and shorter arrive time than those of smaller defects; in the frequency domain, larger defect also shows a stronger amplitude, lower center frequency and lower cutoff frequency.« less

  1. Generation of first hard X-ray pulse at Tsinghua Thomson Scattering X-ray Source.

    PubMed

    Du, Yingchao; Yan, Lixin; Hua, Jianfei; Du, Qiang; Zhang, Zhen; Li, Renkai; Qian, Houjun; Huang, Wenhui; Chen, Huaibi; Tang, Chuanxiang

    2013-05-01

    Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first hard X-ray pulses (51.7 keV) via head-on collision of an 800 nm laser and 46.7 MeV electron beams. The measured yield is 1.0 × 10(6) per pulse with an electron bunch charge of 200 pC and laser pulse energy of 300 mJ. The angular intensity distribution and energy spectra of the X-ray pulse are measured with an electron-multiplying charge-coupled device using a CsI scintillator and silicon attenuators. These measurements agree well with theoretical and simulation predictions. An imaging test using the X-ray pulse at the TTX is also presented.

  2. [Effect of vascular endothelial growth factor and tumor necrosis factor receptor for treatment of avascular necrosis of the femoral head in rabbits].

    PubMed

    Hu, Zhi-ming; Zhou, Ming-qian; Gao, Ji-min

    2008-12-01

    To evaluate the therapeutic effect of vascular endothelial growth factor (VEGF) and tumor necrosis factor receptor (TNFR) on avascular necrosis of the femoral head in rabbits. Avascular necrosis of the femoral head was induced in 26 New Zealand white rabbits by injections of horse serum and prednisolone. The rabbits were then divided into VEGF/TNFR treatment group, VEGF treatment group, and untreated model group, with another 4 normal rabbits as the normal control group. In the two treatment groups, the therapeutic agents were injected percutaneously into the femoral head. Enzyme-linked immunosorbent assay was performed to determine the concentration of TNF-alpha in rabbit serum followed by pathological examination of the changes in the bone tissues, bone marrow hematopoietic tissue and the blood vessels in the femoral head. Compared with the model group, the rabbits with both VEGF and TNFR treatment showed decreased serum concentration of TNF-alpha with obvious new vessel formation, decreased empty bone lacunae in the femoral head and hematopoietic tissue proliferation in the bone marrow cavity. Percutaneous injection of VEGF and TNFR into the femoral head can significantly enhance bone tissue angiogenesis and ameliorate osteonecrosis in rabbits with experimental femoral head necrosis.

  3. SU-F-J-08: Quantitative SPECT Imaging of Ra-223 in a Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, J; Hobbs, R; Sgouros, G

    Purpose: Ra-223 therapy of prostate cancer bone metastases is being used to treat patients routinely. However, the absorbed dose distribution at the macroscopic and microscopic scales remains elusive, due to the inability to image the small activities injected. Accurate activity quantification through imaging is essential to calculate the absorbed dose in organs and sub-units in radiopharmaceutical therapy, enabling personalized absorbed dose-based treatment planning methodologies and more effective and optimal treatments. Methods: A 22 cm diameter by 20 cm long cylindrical phantom, containing a 3.52 cm diameter sphere, was used. A total of 2.01 MBq of Ra-223 was placed in themore » phantom with 177.6 kBq in the sphere. Images were acquired on a dual-head Siemens Symbia T16 gamma camera using three 20% full-width energy windows and centered at 84, 154, and 269 keV (120 projections, 360° rotation, 45 s per view). We have implemented reconstruction of Ra-223 SPECT projections using OS-EM (up to 20 iterations of 10 subsets) with compensation for attenuation using CT-based attenuation maps, collimator-detector response (CDR) (including septal penetration, scatter and Pb x-ray modeling), and scatter in the patient using the effective source scatter estimation (ESSE) method. The CDR functions and scatter kernels required for ESSE were computed using the SIMIND MC simulation code. All Ra-223 photon emissions as well as gamma rays from the daughters Rn-219 and Bi-211 were modeled. Results: The sensitivity of the camera in the three combined windows was 107.3 cps/MBq. The visual quality of the SPECT images was reasonably good and the activity in the sphere was 27% smaller than the true activity. This underestimation is likely due to partial volume effect. Conclusion: Absolute quantitative Ra-223 SPECT imaging is achievable with careful attention to compensate for image degrading factors and system calibration.« less

  4. Condition on Ramond-Ramond fluxes for factorization of worldsheet scattering in anti-de Sitter space

    NASA Astrophysics Data System (ADS)

    Wulff, Linus

    2017-11-01

    Factorization of scattering is the hallmark of integrable 1 +1 dimensional quantum field theories. For factorization of scattering to be possible the set of masses and momenta must be conserved in any two-to-two scattering process. We use this fact to constrain the form of the Ramond-Ramond fluxes for integrable supergravity anti-de Sitter (AdS) backgrounds by analyzing tree-level scattering of two AdS bosons into two fermions on the worldsheet of a Berenstein-Maldacena-Nastase string. We find a condition which can be efficiently used to rule out integrability of AdS strings and therefore of the corresponding AdS/conformal field theory dualities, as we demonstrate for some simple examples.

  5. Effect of Multiple Scattering on the Compton Recoil Current Generated in an EMP, Revisited

    DOE PAGES

    Farmer, William A.; Friedman, Alex

    2015-06-18

    Multiple scattering has historically been treated in EMP modeling through the obliquity factor. The validity of this approach is examined here. A simplified model problem, which correctly captures cyclotron motion, Doppler shifting due to the electron motion, and multiple scattering is first considered. The simplified problem is solved three ways: the obliquity factor, Monte-Carlo, and Fokker-Planck finite-difference. Because of the Doppler effect, skewness occurs in the distribution. It is demonstrated that the obliquity factor does not correctly capture this skewness, but the Monte-Carlo and Fokker-Planck finite-difference approaches do. Here, the obliquity factor and Fokker-Planck finite-difference approaches are then compared inmore » a fuller treatment, which includes the initial Klein-Nishina distribution of the electrons, and the momentum dependence of both drag and scattering. It is found that, in general, the obliquity factor is adequate for most situations. However, as the gamma energy increases and the Klein-Nishina becomes more peaked in the forward direction, skewness in the distribution causes greater disagreement between the obliquity factor and a more accurate model of multiple scattering.« less

  6. [The related factors of head and neck mocosal melanoma with lymph node metastasis].

    PubMed

    Yin, G F; Guo, W; Chen, X H; Huang, Z G

    2017-12-05

    Objective: To investigate the related factors of mucosal melanoma of head and neck with lymph node metastasis for early diagnosis and further treatments. Method: A retrospective analysis of 117 cases of head and neck mucosal malignant melanoma patients which received surgical treatment was performed. Eleven cases of patients with pathologically confirmed lymph node metastasis and 33 cases without lymph node metastasis (1∶3) were randomly selected to analyze. The related factors of lymph node metastasis of head and neck mucosal melanoma patients including age, gender, whether the existence of recurrence, bone invasion, lesion location were analyzed. The single factor and logistic regression analysis were performed, P <0.05 difference was statistically significant. Result: The lymph node metastasis rate of head and neck mucosal melanoma was 9.40%(11/117), the single factor analysis showed that there were 3 factors to be associated with lymph node metastasis, which was recurrence ( P =0.0000), bone invasion ( P =0.001), primary position ( P =0.007). Recurrence ( P =0.021) was a risk factor for lymph node metastasis according to the Logistic regression analysis, and the impact of bone invasion ( P =0.487) and primary location ( P =0.367) remained to be further explored. Conclusion: The patients of head and neck mucosal melanoma with the presence of recurrent usually accompanied by a further progression of the disease, such as lymph node metastasis, so for recurrent patients should pay special attention to the situation of lymph node and choose the reasonable treatment. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  7. Effect of tertiary multileaf collimator (MLC) on foetal dose during three-dimensional conformal radiation therapy (3DCRT) of a brain tumour during pregnancy.

    PubMed

    Sharma, Dayananda S; Jalali, Rakesh; Tambe, Chandrashekhar M; Animesh; Deshpande, Deepak D

    2004-01-01

    The aim of this work was to measure the dose to foetus both in vivo and in vitro during three-dimensional conformal radiation therapy (3DCRT) in a pregnant patient with a pituitary adenoma. The study was then extended to assess the components contributing to the foetal dose such as collimator scatter, internal scatter, head leakage, wedge scatter and multileaf collimator (MLC) effect. A 30-year-old pregnant woman with a non-functioning pituitary macroadenoma was planned for 3DCRT with 6MV X-ray using four equally weighted MLC-shaped non-coplanar wedged portals. In vivo dosimetry was carried out using thermoluminescent (TL) phosphor powder, which was placed at different positions on the patient, corresponding to different locations in the uterus and also at external os. In vitro measurements were also performed on a simulated phantom using the same set-up parameters and beam arrangement to verify the in vivo measured dose. Experiments were carried out to measure the respective contributions of different components towards peripheral dose. In vitro measured dose to foetus was found to be slightly more than that of in vivo measurement with a maximum of 0.044% of the prescribed dose of 45Gy, which corresponded to 0.0199+/-0.0008Gy. Thermoluminescence dosimeter (TLD) kept at the external os of the patient showed a dose of 0.031% of the prescribed dose. Among the various components of the peripheral dose (foetal dose) measured, head leakage was found to be the leading cause contributing 52%, followed by wedge scatter (31%), collimator scatter (14%) and internal scatter (13%). The use of MLC reduced not only the volume of normal brain irradiation as compared to open fields but also the peripheral dose by 10%. Radiotherapy of brain tumours during pregnancy poses a unique clinical situation and decisions to deliver radiotherapy should be taken after detailed in vitro and in vivo dosimetric measurements. Our findings suggest that the beam arrangement using 3-4-fields generally used for 3DCRT of brain tumour with MLC for optimal coverage can be employed for pregnant patients even in early trimester. A possible increase in foetal dose from wedges to a large extent can be compensated with the use of MLC.

  8. Mass-energy and momentum extraction by gravitational wave emission in the merger of two colliding black holes: The non-head-on case

    NASA Astrophysics Data System (ADS)

    Aranha, R. F.; Soares, I. Damião; Tonini, E. V.

    2012-01-01

    We examine numerically the post-merger regime of two nonspining holes in non-head-on collisions in the realm of nonaxisymmetric Robinson-Trautman spacetimes. Characteristic initial data for the system are constructed and evolved via the Robinson-Trautman equation. The numerical integration is performed using a Galerkin spectral method which is sufficiently stable to reach the final configuration of the remnant black hole, when the gravitational wave emission ceases. The initial data contains three independent parameters, the ratio mass α of the individual colliding black holes, their initial premerger infalling velocity and the incidence angle of collision ρ0. The remnant black hole is characterized by its final boost parameter, rest mass and scattering angle. The motion of the remnant black hole is restricted to the plane determined by the directions of the two initial colliding black holes, characterizing a planar collision. The net momentum fluxes carried out by gravitational waves are confined to this plane. We evaluate the efficiency of mass-energy extraction, the total energy and momentum carried out by gravitational waves and the momentum distribution of the remnant black hole for a large domain of initial data parameters. Our analysis is based on the Bondi-Sachs four-momentum conservation laws. The process of mass-energy extraction is shown to be less efficient as the initial data departs from the head-on configuration. Head-on collisions (ρ0=0o) and orthogonal collisions (ρ0=90°) constitute, respectively, upper and lower bounds to the power emission and to the efficiency of mass-energy extraction. On the contrary, head-on collisions and orthogonal collisions constitute, respectively, lower and upper bounds for the momentum of the remnant. Distinct regimes of gravitational wave emission (bursts or quiescent emission) are characterized by the analysis of the time behavior of the gravitational wave power as a function of α. In particular, the net gravitational wave flux is nonzero for equal-mass colliding black holes in non-head-on collisions. The momentum extraction and the patterns of the momentum fluxes, as a function of the incidence angle, are examined. The relation between the incidence angle and the scattering angle closely approximates a relation for the inelastic collision of classical particles in Newtonian dynamics.

  9. Adjustable lead glass shielding device for use with an over-the-table x-ray tube.

    PubMed

    Eubig, C; Groves, B M; Davey, G

    1978-12-01

    Sources of scattered radiation exposure to personnel from a ceiling-mounted x-ray tube were examined at the side of cardiac catheterization patients. A fully adjustable mounting for a lead glass shield was designed to afford maximum radiation protection to the attending physician's head and neck area, while minimizing interference with the procedure.

  10. Investigation of scattering coefficients and anisotropy factors of human cancerous and normal prostate tissues using Mie theory

    NASA Astrophysics Data System (ADS)

    Pu, Yang; Chen, Jun; Wang, Wubao

    2014-02-01

    The scattering coefficient, μs, the anisotropy factor, g, the scattering phase function, p(θ), and the angular dependence of scattering intensity distributions of human cancerous and normal prostate tissues were systematically investigated as a function of wavelength, scattering angle and scattering particle size using Mie theory and experimental parameters. The Matlab-based codes using Mie theory for both spherical and cylindrical models were developed and applied for studying the light propagation and the key scattering properties of the prostate tissues. The optical and structural parameters of tissue such as the index of refraction of cytoplasm, size of nuclei, and the diameter of the nucleoli for cancerous and normal human prostate tissues obtained from the previous biological, biomedical and bio-optic studies were used for Mie theory simulation and calculation. The wavelength dependence of scattering coefficient and anisotropy factor were investigated in the wide spectral range from 300 nm to 1200 nm. The scattering particle size dependence of μs, g, and scattering angular distributions were studied for cancerous and normal prostate tissues. The results show that cancerous prostate tissue containing larger size scattering particles has more contribution to the forward scattering in comparison with the normal prostate tissue. In addition to the conventional simulation model that approximately considers the scattering particle as sphere, the cylinder model which is more suitable for fiber-like tissue frame components such as collagen and elastin was used for developing a computation code to study angular dependence of scattering in prostate tissues. To the best of our knowledge, this is the first study to deal with both spherical and cylindrical scattering particles in prostate tissues.

  11. Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy.

    PubMed

    Jones, A Kyle; Pasciak, Alexander S; Wagner, Louis K

    2016-07-01

    To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (Eavg) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

  12. Protein aggregation studied by forward light scattering and light transmission analysis

    NASA Astrophysics Data System (ADS)

    Penzkofer, A.; Shirdel, J.; Zirak, P.; Breitkreuz, H.; Wolf, E.

    2007-12-01

    The aggregation of the circadian blue-light photo-receptor cryptochrome from Drosophila melanogaster (dCry) is studied by transmission and forward light scattering measurement in the protein transparent wavelength region. The light scattering in forward direction is caused by Rayleigh scattering which is proportional to the degree of aggregation. The light transmission through the samples in the transparent region is reduced by Mie light scattering in all directions. It depends on the degree of aggregation and the monomer volume fill factor of the aggregates (less total scattering with decreasing monomer volume fill factor of protein globule) allowing a distinction between tightly packed protein aggregation (monomer volume fill factor 1) and loosely packed protein aggregation (monomer volume fill factor less than 1). An increase in aggregation with temperature, concentration, and blue-light exposure is observed. At a temperature of 4 °C and a protein concentration of less than 0.135 mM no dCry aggregation was observed, while at 24 °C and 0.327 mM gelation occurred (loosely packed aggregates occupying the whole solution volume).

  13. Reduced head-neck offset in nontraumatic osteonecrosis of the femoral head.

    PubMed

    Fraitzl, Christian R; Kappe, Thomas; Brugger, Annina; Billich, Christian; Reichel, Heiko

    2013-08-01

    Risk factors for nontraumatic osteonecrosis of the femoral head have in common that they trigger intravascular coagulation and thus lead to devascularization of the femoral head. In part of the patients, however, no risk factors seem to be evident. Mechanical reasons contributing to nontraumatic osteonecrosis have not been discussed so far. We hypothesized that recurrent traumatization of the vessels supplying the femoral head by a cam-type mechanism as in femoroacetabular impingement could add to intravascular coagulation. We, therefore, asked whether structural abnormalities at the femoral head-neck junction indicative of such a mechanism could be observed in radiographs of patients with osteonecrosis of the femoral head. The preoperative anteroposterior and lateral radiographs of 77 patients who underwent surgery because of osteonecrosis of the femoral head were retrospectively screened for a reduced head-neck offset by measuring the α-angle. For comparison, the α-angle was measured on anteroposterior and lateral radiographs of 339 control subjects without evident underlying hip pathology. The mean α-angle was 62.8° (SD 18.7°) for anteroposterior and 67.6° (SD 13.2°) for lateral radiographs in patients with nontraumatic osteonecrosis of the femoral head, whereas in control subjects, the mean α-angle was 47.2° (SD 9.6°) (p < 0.0001) and 47.6° (SD 10.3°) (p < 0.0001), respectively. A reduced head-neck offset in patients with nontraumatic osteonecrosis of the femoral head may act as a mechanical (co-)factor in developing osteonecrosis of the femoral head.

  14. X-Ray Form Factor, Attenuation and Scattering Tables

    National Institute of Standards and Technology Data Gateway

    SRD 66 X-Ray Form Factor, Attenuation and Scattering Tables (Web, free access)   This database collects tables and graphs of the form factors, the photoabsorption cross section, and the total attenuation coefficient for any element (Z <= 92).

  15. Scaling EUV and X-ray Thomson sources to optical free-electron laser operation with traveling-wave Thomson scattering (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Steiniger, Klaus; Albach, Daniel; Debus, Alexander; Loeser, Markus; Pausch, Richard; Roeser, Fabian; Schramm, Ulrich; Siebold, Matthias; Bussmann, Michael

    2017-05-01

    Traveling-Wave Thomson-Scattering (TWTS) allows for the realization of optical free-electron lasers (OFELs) from the interaction of short, high-power laser pulses with brilliant relativistic electron bunches. The laser field provides the optical undulator which is traversed by the electrons. In order to achieve coherent amplification of radiation through electron microbunching the interaction between electrons and laser must be maintained over hundreds to thousands of undulator periods. Traveling-Wave Thomson-Scattering is the only scattering geometry so far allowing for the realization of optical undulators of this length which is at the same time scalable from extreme ultraviolet to X-ray photon energies. TWTS is also applicable for the realization of incoherent high peak brightness hard X-ray to gamma-ray sources which can provide orders of magnitude higher photon output than classic head-on Thomson sources. In contrast to head-on Thomson sources TWTS employs a side-scattering geometry where laser and electron propagation direction of motion enclose an angle. Tilting the laser pulse front with respect to the wave front by half of this interaction angle optimizes electron and laser pulse overlap. In the side-scattering geometry the tilt of the pulse-front compensates the spatial offset between electrons and laser pulse-front which would be present otherwise for an electron bunch far from the interaction point where it overlaps with the laser pulse center. Thus the laser pulse-front tilt ensures continuous overlap between laser pulse and electrons while these traverse the laser pulse cross-sectional area. This allows to control the interaction distance in TWTS by the laser pulse width rather than laser pulse duration as is the case for head-on Thomson scattering. Utilizing petawatt class laser pulses with millimeter to centimeter scale width allows for the realization of compact optical undulators with thousands of periods. When laser pulses for TWTS are prepared, care has to be taken of laser dispersion. Especially for scenarios featuring interaction angles of several ten to over one hundred degree the angular dispersion originating from laser pulse-front tilt can significantly prolong the pulse duration during the interaction which leads to a decrease in optical undulator amplitude and eventually terminates the interaction long before the target interaction distance is reached. In the talk it is shown how a pair of two gratings can be used to first generate the pulse-front tilt and second control and compensate dispersion during the interaction by utilizing the plane of optimum compression. Furthermore an experimental setup strategy is presented allowing for an interaction outside the laser pulse focus. This is a necessity for TWTS OFELs requiring focusing to reach optical undulator strengths on the order of unity since the centimeter scale laser pulse width at the interaction point result in turn in Rayleigh lengths on the order of one hundred meter and thus in laser focusing distances of several hundred meter. The talk shows how an out-of-focus interaction geometry utilizing strong focusing of the incident laser pulse needs to be designed in order to regain compactness by reducing the focusing distance by one to two orders of magnitude.

  16. Measurement of Total Scatter Factor for Stereotactic Cones with Plastic Scintillation Detector

    PubMed Central

    Chaudhari, Suresh H; Dobhal, Rishabh; Kinhikar, Rajesh A.; Kadam, Sudarshan S.; Deshpande, Deepak D.

    2017-01-01

    Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be −1.3%, 1.9%, −0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data. PMID:28405102

  17. Measurement of Total Scatter Factor for Stereotactic Cones with Plastic Scintillation Detector.

    PubMed

    Chaudhari, Suresh H; Dobhal, Rishabh; Kinhikar, Rajesh A; Kadam, Sudarshan S; Deshpande, Deepak D

    2017-01-01

    Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx ™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be -1.3%, 1.9%, -0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data.

  18. The Effects of Head Start Enrollment Duration on Migrant Children's Dental Health

    ERIC Educational Resources Information Center

    Lee, Kyunghee

    2017-01-01

    The purpose of this study was to identify factors affecting Migrant Head Start (MHS) children's dental health. Enrollment duration (number of years and weeks enrolled) and individual and family factors were considered. Children (N = 931) who enrolled in Michigan Migrant Head Start during 2012-2013 were selected for the study sample and classified…

  19. Scattered dose to radiosensitive organs and associated risk for cancer development from head and neck radiotherapy in pediatric patients.

    PubMed

    Kourinou, Kalliopi M; Mazonakis, Michalis; Lyraraki, Efrosini; Stratakis, John; Damilakis, John

    2013-11-01

    The purpose of this study was to measure the scattered dose to out-of-field organs from head and neck radiotherapy in pediatric patients and to estimate the risk for second cancer induction to individual organs. Radiotherapy for thalamic tumor, brain tumor, acute leukemia and Hodgkin's disease in the neck region was simulated on 5 and 10-year-old pediatric phantoms with a 6 MV photon beam. The radiation dose to thyroid, breast, lung, stomach, ovaries, bladder, liver, uterus, prostate and colon was measured using thermoluminescent dosimeters. The methodology, provided by the BEIR VII report was used for the second cancer risk estimations. Peripheral dose range for a simulated 5-year-old patient was 0.019%-1.572% of the given tumor dose. The corresponding range at the advanced patient age was reduced to 0.018%-1.468%. The second cancer risk per fraction for male patients varied from 3 to 215 per 1,000,000 patients depending upon the age at the time of exposure, primary cancer site and organ scattered dose. The corresponding risk for females was 1-1186 per 1,000,000 patients. The higher risk values were found for breast, thyroid and lung cancer development. The current data concerning the risk magnitude for developing subsequent neoplasms to various out-of-field organs may be of value for health care professionals in the follow-up studies of childhood cancer survivors. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. [International focuses in the studies of chronic pelvic pain syndrome: A social network analysis].

    PubMed

    Wen, Li-Jie; Pan, Xian-Wei; Yang, Bo

    2016-10-01

    To analyze the internationally published literature relevant to chronic pelvic pain syndrome (CPPS) using bibliometrics and social network analysis, and investigate the current status and focuses of CPPS studies. We identified 692 publications on CPPS by searching PubMed up to December 2015, extracted their subject headings, calculated the frequencies of the headings, and constructed a co-occurrence network of the high-frequency (≥10) subject headings. Then we studied the features and structure of the co-occurrence network by analyzing its attributes and topological structure. The density of the constructed co-occurrence network was 0.111, with an average distance of 2.886 and a clustering coefficient of 0.685. Its low density, long average distance and high clustering coefficient indicated that it was a sparse network, with a slow speed of information spreading among nodes but a strong potential coherence, which suggested that the current topics in the study of CPPS were scattered and weakly correlated, with a high possibility of being integrated. Based on the topological structure of the co-occurrence network, the topics in the study of CPPS were divided into six aspects: diagnosis and classification, drug therapy, treatment, etiology, microbiology, psychology, and epidemiology, the more important of which were diagnosis and classification, drug therapy, treatment and etiology. A system has been formed in the studies of CPPS, focusing on the diagnosis, drug therapy, and etiology of the disease. However, the research topics are relatively scattered and frequently repeated. Therefore, more attention should be paid to the macrocosmic guidance and rational coordination of the researches on CPPS.

  1. Physical properties of meteoroids based on middle and upper atmosphere radar measurements

    NASA Astrophysics Data System (ADS)

    Gritsevich, M.; Kero, J.; Virtanen, J.; Szasz, C.; Nakamura, T.; Peltoniemi, J.; Koschny, D.

    2014-07-01

    We present a novel approach to reliably interpret the meteor head-echo scattering measurements detected by the 46.5 MHz MU radar system near Shigaraki, Japan. A meteor head echo is caused by radio waves scattered from the dense region of plasma surrounding and co-moving with a meteoroid during atmospheric flight. The signal Doppler shift and/or range rate of the target can therefore be used to determine meteoroid velocity. The data reduction steps include determining the exact trajectory of the meteoroids entering the observation volume of the antenna beam and calculating meteoroid mass and velocity as a function of time. The model is built using physically-based parametrization. The considered observation volume is narrow, elongated in the vertical direction, and its area of greatest sensitivity covers a circular area of about 10 km diameter at an altitude of 100 km above the radar. Over 100,000 meteor head echoes have been detected over past years of observations. Most of the events are faint with no alternative to be detected visually or with intensified video (ICCD) cameras. In this study we are focusing on objects which have entered the atmosphere with almost vertical trajectories, to ensure the observed segment of the trajectory to be as complete as possible, without loss of its beginning or end part due to beam-pattern-related loss of signal power. The analysis output parameters are range, altitude, radial velocity, meteoroid velocity, instantaneous target position, Radar Cross Section (RCS), meteor radiant, meteoroid ballistic and ablation coefficients, mass loss parameter and meteoroid mass, with possibility to derive other parameters.

  2. Physical Properties of Meteoroids based on Middle and Upper Atmosphere Radar Measurements

    NASA Astrophysics Data System (ADS)

    Gritsevich, Maria; Nakamura, Takuji; Kero, Johan; Szasz, Csilla; Virtanen, Jenni; Peltoniemi, Jouni; Koschny, Detlef

    We present a novel approach to reliably interpret the meteor head echo scattering measurements detected by the 46.5 MHz MU radar system near Shigaraki, Japan. A meteor head echo is caused by radio waves scattered from the dense region of plasma surrounding and co-moving with a meteoroid during atmospheric flight. The signal Doppler shift and/or range rate of the target can therefore be used to determine meteoroid velocity. The data reduction steps include determining the exact trajectory of the meteoroids entering the observation volume of the antenna beam and calculating meteoroid mass and velocity as a function of time. The model is built using physically based parameterization. The considered observation volume is narrow, elongated in the vertical direction, and its area of greatest sensitivity covers a circular area of about 10 km diameter at an altitude of 100 km above the radar. Over 100000 meteor head echoes have been detected over past years of observations. Most of the events are faint with no alternative to be detected visually or with intensified video (ICCD) cameras. In this study we are focusing on objects which have entered the atmosphere with almost vertical trajectories, to ensure the observed segment of the trajectory to be as complete as possible, without loss of its beginning or end part due to beam-pattern related loss of signal power. The analysis output parameters are range, altitude, radial velocity, meteoroid velocity, instantaneous target position, Radar Cross Section (RCS), meteor radiant, meteoroid ballistic and ablation coefficients, mass loss parameter and meteoroid mass, with possibility to derive other parameters.

  3. Microstructural effect on radiative scattering coefficient and asymmetry factor of anisotropic thermal barrier coatings

    NASA Astrophysics Data System (ADS)

    Chen, X. W.; Zhao, C. Y.; Wang, B. X.

    2018-05-01

    Thermal barrier coatings are common porous materials coated on the surface of devices operating under high temperatures and designed for heat insulation. This study presents a comprehensive investigation on the microstructural effect on radiative scattering coefficient and asymmetry factor of anisotropic thermal barrier coatings. Based on the quartet structure generation set algorithm, the finite-difference-time-domain method is applied to calculate angular scattering intensity distribution of complicated random microstructure, which takes wave nature into account. Combining Monte Carlo method with Particle Swarm Optimization, asymmetry factor, scattering coefficient and absorption coefficient are retrieved simultaneously. The retrieved radiative properties are identified with the angular scattering intensity distribution under different pore shapes, which takes dependent scattering and anisotropic pore shape into account implicitly. It has been found that microstructure significantly affects the radiative properties in thermal barrier coatings. Compared with spherical shape, irregular anisotropic pore shape reduces the forward scattering peak. The method used in this paper can also be applied to other porous media, which designs a frame work for further quantitative study on porous media.

  4. Theoretical evaluation of accuracy in position and size of brain activity obtained by near-infrared topography

    NASA Astrophysics Data System (ADS)

    Kawaguchi, Hiroshi; Hayashi, Toshiyuki; Kato, Toshinori; Okada, Eiji

    2004-06-01

    Near-infrared (NIR) topography can obtain a topographical distribution of the activated region in the brain cortex. Near-infrared light is strongly scattered in the head, and the volume of tissue sampled by a source-detector pair on the head surface is broadly distributed in the brain. This scattering effect results in poor resolution and contrast in the topographic image of the brain activity. In this study, a one-dimensional distribution of absorption change in a head model is calculated by mapping and reconstruction methods to evaluate the effect of the image reconstruction algorithm and the interval of measurement points for topographic imaging on the accuracy of the topographic image. The light propagation in the head model is predicted by Monte Carlo simulation to obtain the spatial sensitivity profile for a source-detector pair. The measurement points are one-dimensionally arranged on the surface of the model, and the distance between adjacent measurement points is varied from 4 mm to 28 mm. Small intervals of the measurement points improve the topographic image calculated by both the mapping and reconstruction methods. In the conventional mapping method, the limit of the spatial resolution depends upon the interval of the measurement points and spatial sensitivity profile for source-detector pairs. The reconstruction method has advantages over the mapping method which improve the results of one-dimensional analysis when the interval of measurement points is less than 12 mm. The effect of overlapping of spatial sensitivity profiles indicates that the reconstruction method may be effective to improve the spatial resolution of a two-dimensional reconstruction of topographic image obtained with larger interval of measurement points. Near-infrared topography with the reconstruction method potentially obtains an accurate distribution of absorption change in the brain even if the size of absorption change is less than 10 mm.

  5. Structure of FcRY, an avian immunoglobulin receptor related to mammalian mannose receptors, and its complex with IgY

    PubMed Central

    He, Yongning; Bjorkman, Pamela J.

    2011-01-01

    Fc receptors transport maternal antibodies across epithelial cell barriers to passively immunize newborns. FcRY, the functional counterpart of mammalian FcRn (a major histocompatibility complex homolog), transfers IgY across the avian yolk sac, and represents a new class of Fc receptor related to the mammalian mannose receptor family. FcRY and FcRn bind immunoglobulins at pH ≤6.5, but not pH ≥7, allowing receptor–ligand association inside intracellular vesicles and release at the pH of blood. We obtained structures of monomeric and dimeric FcRY and an FcRY–IgY complex and explored FcRY's pH-dependent binding mechanism using electron cryomicroscopy (cryoEM) and small-angle X-ray scattering. The cryoEM structure of FcRY at pH 6 revealed a compact double-ring “head,” in which the N-terminal cysteine-rich and fibronectin II domains were folded back to contact C-type lectin-like domains 1–6, and a “tail” comprising C-type lectin-like domains 7–8. Conformational changes at pH 8 created a more elongated structure that cannot bind IgY. CryoEM reconstruction of FcRY dimers at pH 6 and small-angle X-ray scattering analysis at both pH values confirmed both structures. The cryoEM structure of the FcRY–IgY revealed symmetric binding of two FcRY heads to the dimeric FcY, each head contacting the CH4 domain of one FcY chain. FcRY shares structural properties with mannose receptor family members, including a head and tail domain organization, multimerization that may regulate ligand binding, and pH-dependent conformational changes. Our results facilitate understanding of immune recognition by the structurally related mannose receptor family and comparison of diverse methods of Ig transport across evolution. PMID:21746914

  6. Materials Design via Optimized Intramolecular Noncovalent Interactions for High-Performance Organic Semiconductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Xiaojie; Liao, Qiaogan; Manley, Eric F.

    2016-03-15

    We report the design, synthesis, and implemention in semiconducting polymers of a novel head-to-head linkage containing the TRTOR (3-alkyl-3'-alkoxy-2,2'-bithiophene) donor subunit having a single strategically optimized, planarizing noncovalent S···O interaction. Diverse complementary thermal, optical, electrochemical, X-ray scattering, electrical, photovoltaic, and electron microscopic characterization techniques are applied to establish structure-property correlations in a TRTOR-based polymer series. In comparison to monomers having double S···O interactions, replacing one alkoxy substituent with a less electron-donating alkyl one yields TRTOR-based polymers with significantly depressed (0.2-0.3 eV) HOMOs. Furthermore, the weaker single S···O interaction and greater TRTOR steric encumberance enhances materials processability without sacrificing backbone planarity.more » From another perspective, TRTOR has comparable electronic properties to ring-fused 5Hdithieno[ 3,2-b:2',3'-d]pyran (DTP) subunits, but a centrosymmetric geometry which promotes a more compact and ordered structure than bulkier, axisymmetric DTP. Compared to monosubstituted TTOR (3-alkoxy-2,2'-bithiophene), alkylation at the TRTOR bithiophene 3-position enhances conjugation and polymer crystallinity with contracted π-π stacking. Grazing incidence wide-angle X-ray scattering (GIWAXS) data reveal that the greater steric hindrance and the weaker single S···O interaction are not detrimental to close packing and high crystallinity. As a proof of materials design, copolymerizing TRTOR with phthalimides yields copolymers with promising thin-film transistor mobility as high as 0.42 cm2/(V·s) and 6.3% power conversion efficiency in polymer solar cells, the highest of any phthalimide copolymers reported to date. The depressed TRTOR HOMOs imbue these polymers with substantially increased Ion/Ioff ratios and Voc’s versus analogous subunits with multiple electron donating, planarizing alkoxy substituents. Implementing a head-to-head linkage with an alkyl/alkoxy substitution pattern and a single S···O interaction is a promising strategy for organic electronics materials design.« less

  7. Portable Wideband Microwave Imaging System for Intracranial Hemorrhage Detection Using Improved Back-projection Algorithm with Model of Effective Head Permittivity

    PubMed Central

    Mobashsher, Ahmed Toaha; Mahmoud, A.; Abbosh, A. M.

    2016-01-01

    Intracranial hemorrhage is a medical emergency that requires rapid detection and medication to restrict any brain damage to minimal. Here, an effective wideband microwave head imaging system for on-the-spot detection of intracranial hemorrhage is presented. The operation of the system relies on the dielectric contrast between healthy brain tissues and a hemorrhage that causes a strong microwave scattering. The system uses a compact sensing antenna, which has an ultra-wideband operation with directional radiation, and a portable, compact microwave transceiver for signal transmission and data acquisition. The collected data is processed to create a clear image of the brain using an improved back projection algorithm, which is based on a novel effective head permittivity model. The system is verified in realistic simulation and experimental environments using anatomically and electrically realistic human head phantoms. Quantitative and qualitative comparisons between the images from the proposed and existing algorithms demonstrate significant improvements in detection and localization accuracy. The radiation and thermal safety of the system are examined and verified. Initial human tests are conducted on healthy subjects with different head sizes. The reconstructed images are statistically analyzed and absence of false positive results indicate the efficacy of the proposed system in future preclinical trials. PMID:26842761

  8. Portable Wideband Microwave Imaging System for Intracranial Hemorrhage Detection Using Improved Back-projection Algorithm with Model of Effective Head Permittivity

    NASA Astrophysics Data System (ADS)

    Mobashsher, Ahmed Toaha; Mahmoud, A.; Abbosh, A. M.

    2016-02-01

    Intracranial hemorrhage is a medical emergency that requires rapid detection and medication to restrict any brain damage to minimal. Here, an effective wideband microwave head imaging system for on-the-spot detection of intracranial hemorrhage is presented. The operation of the system relies on the dielectric contrast between healthy brain tissues and a hemorrhage that causes a strong microwave scattering. The system uses a compact sensing antenna, which has an ultra-wideband operation with directional radiation, and a portable, compact microwave transceiver for signal transmission and data acquisition. The collected data is processed to create a clear image of the brain using an improved back projection algorithm, which is based on a novel effective head permittivity model. The system is verified in realistic simulation and experimental environments using anatomically and electrically realistic human head phantoms. Quantitative and qualitative comparisons between the images from the proposed and existing algorithms demonstrate significant improvements in detection and localization accuracy. The radiation and thermal safety of the system are examined and verified. Initial human tests are conducted on healthy subjects with different head sizes. The reconstructed images are statistically analyzed and absence of false positive results indicate the efficacy of the proposed system in future preclinical trials.

  9. WE-G-204-06: Grid-Line Artifact Minimization for High Resolution Detectors Using Iterative Residual Scatter Correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rana, R; Bednarek, D; Rudin, S

    2015-06-15

    Purpose: Anti-scatter grid-line artifacts are more prominent for high-resolution x-ray detectors since the fraction of a pixel blocked by the grid septa is large. Direct logarithmic subtraction of the artifact pattern is limited by residual scattered radiation and we investigate an iterative method for scatter correction. Methods: A stationary Smit-Rοntgen anti-scatter grid was used with a high resolution Dexela 1207 CMOS X-ray detector (75 µm pixel size) to image an artery block (Nuclear Associates, Model 76-705) placed within a uniform head equivalent phantom as the scattering source. The image of the phantom was divided by a flat-field image obtained withoutmore » scatter but with the grid to eliminate grid-line artifacts. Constant scatter values were subtracted from the phantom image before dividing by the averaged flat-field-with-grid image. The standard deviation of pixel values for a fixed region of the resultant images with different subtracted scatter values provided a measure of the remaining grid-line artifacts. Results: A plot of the standard deviation of image pixel values versus the subtracted scatter value shows that the image structure noise reaches a minimum before going up again as the scatter value is increased. This minimum corresponds to a minimization of the grid-line artifacts as demonstrated in line profile plots obtained through each of the images perpendicular to the grid lines. Artifact-free images of the artery block were obtained with the optimal scatter value obtained by this iterative approach. Conclusion: Residual scatter subtraction can provide improved grid-line artifact elimination when using the flat-field with grid “subtraction” technique. The standard deviation of image pixel values can be used to determine the optimal scatter value to subtract to obtain a minimization of grid line artifacts with high resolution x-ray imaging detectors. This study was supported by NIH Grant R01EB002873 and an equipment grant from Toshiba Medical Systems Corp.« less

  10. Influence of the spectral power distribution of a LED on the illuminance responsivity of a photometer

    NASA Astrophysics Data System (ADS)

    Sametoglu, Ferhat

    2008-09-01

    The measurement accuracy in the photometric quantities measured through photometer head is determined by the value of the spectral mismatch correction factor ( c( St, Ss)), which is defined as a function of spectral power distribution of light sources, besides illuminance responsivity of the photometer head used. This factor is more important when photometric quantities of the light-emitting diode (LED) style optical sources, which radiate within relatively narrow spectral bands as compared with that of other optical sources, are being measured. Variations of the illuminance responsivities of various V( λ)-adopted photometer heads are discussed. High-power-colored LEDs, manufactured by Lumileds Lighting Co., were used as light sources and their relative spectral power distributions (RSPDs) were measured using a spectrometer-based optical setup. Dependences of the c( St, Ss) factors of three types of photometer heads ( f1'=1.4%, f1'=0.8% and f1'=0.5%) with wavelength and influences of the factors on the illuminance responsivities of photometer heads are presented.

  11. Plane-dependent ML scatter scaling: 3D extension of the 2D simulated single scatter (SSS) estimate.

    PubMed

    Rezaei, Ahmadreza; Salvo, Koen; Vahle, Thomas; Panin, Vladimir; Casey, Michael; Boada, Fernando; Defrise, Michel; Nuyts, Johan

    2017-07-24

    Scatter correction is typically done using a simulation of the single scatter, which is then scaled to account for multiple scatters and other possible model mismatches. This scaling factor is determined by fitting the simulated scatter sinogram to the measured sinogram, using only counts measured along LORs that do not intersect the patient body, i.e. 'scatter-tails'. Extending previous work, we propose to scale the scatter with a plane dependent factor, which is determined as an additional unknown in the maximum likelihood (ML) reconstructions, using counts in the entire sinogram rather than only the 'scatter-tails'. The ML-scaled scatter estimates are validated using a Monte-Carlo simulation of a NEMA-like phantom, a phantom scan with typical contrast ratios of a 68 Ga-PSMA scan, and 23 whole-body 18 F-FDG patient scans. On average, we observe a 12.2% change in the total amount of tracer activity of the MLEM reconstructions of our whole-body patient database when the proposed ML scatter scales are used. Furthermore, reconstructions using the ML-scaled scatter estimates are found to eliminate the typical 'halo' artifacts that are often observed in the vicinity of high focal uptake regions.

  12. Architectural constraints are a major factor reducing path integration accuracy in the rat head direction cell system.

    PubMed

    Page, Hector J I; Walters, Daniel; Stringer, Simon M

    2015-01-01

    Head direction cells fire to signal the direction in which an animal's head is pointing. They are able to track head direction using only internally-derived information (path integration)In this simulation study we investigate the factors that affect path integration accuracy. Specifically, two major limiting factors are identified: rise time, the time after stimulation it takes for a neuron to start firing, and the presence of symmetric non-offset within-layer recurrent collateral connectivity. On the basis of the latter, the important prediction is made that head direction cell regions directly involved in path integration will not contain this type of connectivity; giving a theoretical explanation for architectural observations. Increased neuronal rise time is found to slow path integration, and the slowing effect for a given rise time is found to be more severe in the context of short conduction delays. Further work is suggested on the basis of our findings, which represent a valuable contribution to understanding of the head direction cell system.

  13. EXACT DOSE X-IRRADIATION OF VARIOUS REGIONS OF THE HEAD AND VISUAL SENSATIONS--X-RAY LOCATION METHOD OF STUDY OF THE REACTIVITY OF THE CENTRAL NERVOUS SYSTEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gurtovoi, G.K.; Burdianskaya, E.O.

    1960-01-01

    The primary substrate excited by threshold doses of x radiation of the normal human eye causes perception of a light flash in the retinal region. The threshold dose for the retina is about 1 mr; the threshold absorbed dose is about 1 mrad. Persons with a removed eyeball, on irradiation of the operated region with a frontal x-ray beam, perceive a flash of light at definite doses of radiation. Six persons taking part in an experiment saw a flash at doses of 17 to 150 mr (different observers saw flash at different doses) and did not see flash at dosesmore » of 5 to 90 mr. The cause of x-ray phosphene on frontal irradiation of the region of the removed eye with threshold doses is neither the reactivity of the optic nerve stump, the reactivity of the parts of the brain irradiated, nor the sensitivity of the skin receptors. In the cases considered, the cause of x-ray phosphene was irradiation of the retina of the nomnal eye by scattered x rays. The averaged coefficient of scatter was about 2%. On irradiation of the occiptal regions of the brain in subjects with normal eyes at a dose of about 150 mr, one subject perceived a flash of light. In this case, the absorbed dose for the occipital regions of the brain was about 40 mrad. The reason for this phenomenon must be explored. Stimulation of the cerebral formations (after atrophic changes in the visual tract and cortex) by x radia tion with a dose of up to 3 r, did not cause visual sensations. With the disposition of the beam, the absorbed dose for the chiasma was about 1 rad and for the occipital regions about 0.2 rad. In the study of threshold visual sensation and their causes on x irradiation of various regions of the head, it is important to apply defined doses of radiation. Scatter of the x rays in the head must be taken into consideration. (auth)« less

  14. Comparison of the GHSSmooth and the Rayleigh-Rice surface scatter theories

    NASA Astrophysics Data System (ADS)

    Harvey, James E.; Pfisterer, Richard N.

    2016-09-01

    The scalar-based GHSSmooth surface scatter theory results in an expression for the BRDF in terms of the surface PSD that is very similar to that provided by the rigorous Rayleigh-Rice (RR) vector perturbation theory. However it contains correction factors for two extreme situations not shared by the RR theory: (i) large incident or scattered angles that result in some portion of the scattered radiance distribution falling outside of the unit circle in direction cosine space, and (ii) the situation where the relevant rms surface roughness, σrel, is less than the total intrinsic rms roughness of the scattering surface. Also, the RR obliquity factor has been discovered to be an approximation of the more general GHSSmooth obliquity factor due to a little-known (or long-forgotten) implicit assumption in the RR theory that the surface autocovariance length is longer than the wavelength of the scattered radiation. This assumption allowed retaining only quadratic terms and lower in the series expansion for the cosine function, and results in reducing the validity of RR predictions for scattering angles greater than 60°. This inaccurate obliquity factor in the RR theory is also the cause of a complementary unrealistic "hook" at the high spatial frequency end of the predicted surface PSD when performing the inverse scattering problem. Furthermore, if we empirically substitute the polarization reflectance, Q, from the RR expression for the scalar reflectance, R, in the GHSSmooth expression, it inherits all of the polarization capabilities of the rigorous RR vector perturbation theory.

  15. Ab initio calculation of the ion feature in x-ray Thomson scattering.

    PubMed

    Plagemann, Kai-Uwe; Rüter, Hannes R; Bornath, Thomas; Shihab, Mohammed; Desjarlais, Michael P; Fortmann, Carsten; Glenzer, Siegfried H; Redmer, Ronald

    2015-07-01

    The spectrum of x-ray Thomson scattering is proportional to the dynamic structure factor. An important contribution is the ion feature which describes elastic scattering of x rays off electrons. We apply an ab initio method for the calculation of the form factor of bound electrons, the slope of the screening cloud of free electrons, and the ion-ion structure factor in warm dense beryllium. With the presented method we can calculate the ion feature from first principles. These results will facilitate a better understanding of x-ray scattering in warm dense matter and an accurate measurement of ion temperatures which would allow determining nonequilibrium conditions, e.g., along shock propagation.

  16. The Role of Prothrombotic Factors in the Ocular Manifestations of Abusive and Non-Abusive Head Trauma: A Feasibility Study

    ERIC Educational Resources Information Center

    Yu, Anna; Stephens, Derek; Feldman, Brian M.; Parkin, Patricia C.; Kahr, Walter H. A.; Brandao, Leonardo R.; Shouldice, Michelle; Levin, Alex V.

    2012-01-01

    Objectives: Retinal hemorrhage is a cardinal manifestation of abusive head injury. Thrombophilia is relatively common in the general population and in adults can be associated with retinal hemorrhage. The specificity of retinal hemorrhage for abusive head trauma in the presence of prothrombotic factors, in particular following non-abusive head…

  17. Whole-Body Single-Bed Time-of-Flight RPC-PET: Simulation of Axial and Planar Sensitivities With NEMA and Anthropomorphic Phantoms

    NASA Astrophysics Data System (ADS)

    Crespo, Paulo; Reis, João; Couceiro, Miguel; Blanco, Alberto; Ferreira, Nuno C.; Marques, Rui Ferreira; Martins, Paulo; Fonte, Paulo

    2012-06-01

    A single-bed, whole-body positron emission tomograph based on resistive plate chambers has been proposed (RPC-PET). An RPC-PET system with an axial field-of-view (AFOV) of 2.4 m has been shown in simulation to have higher system sensitivity using the NEMA NU2-1994 protocol than commercial PET scanners. However, that protocol does not correlate directly with lesion detectability. The latter is better correlated with the planar (slice) sensitivity, obtained with a NEMA NU2-2001 line-source phantom. After validation with published data for the GE Advance, Siemens TruePoint and TrueV, we study by simulation their axial sensitivity profiles, comparing results with RPC-PET. Planar sensitivities indicate that RPC-PET is expected to outperform 16-cm (22-cm) AFOV scanners by a factor 5.8 (3.0) for 70-cm-long scans. For 1.5-m scans (head to mid-legs), the sensitivity gain increases to 11.7 (6.7). Yet, PET systems with large AFOV provide larger coverage but also larger attenuation in the object. We studied these competing effects with both spherical- and line-sources immersed in a 27-cm-diameter water cylinder. For 1.5-m-long scans, the planar sensitivity drops one order of magnitude in all scanners, with RPC-PET outperforming 16-cm (22-cm) AFOV scanners by a factor 9.2 (5.3) without considering the TOF benefit. A gain in the effective sensitivity is expected with TOF iterative reconstruction. Finally, object scatter in an anthropomorphic phantom is similar for RPC-PET and modern, scintillator-based scanners, although RPC-PET benefits further if its TOF information is utilized to exclude scatter events occurring outside the anthropomorphic phantom.

  18. Semi-synthesis of a HGF/SF kringle one (K1) domain scaffold generates a potent in vivo MET receptor agonist.

    PubMed

    Simonneau, Claire; Bérénice Leclercq; Mougel, Alexandra; Adriaenssens, Eric; Paquet, Charlotte; Raibaut, Laurent; Ollivier, Nathalie; Drobecq, Hervé; Marcoux, Julien; Cianférani, Sarah; Tulasne, David; de Jonge, Hugo; Melnyk, Oleg; Vicogne, Jérôme

    2015-03-01

    The development of MET receptor agonists is an important goal in regenerative medicine, but is limited by the complexity and incomplete understanding of its interaction with HGF/SF (Hepatocyte Growth Factor/Scatter Factor). NK1 is a natural occurring agonist comprising the N-terminal (N) and the first kringle (K1) domains of HGF/SF. In the presence of heparin, NK1 can self-associate into a "head to tail" dimer which is considered as the minimal structural module able to trigger MET dimerization and activation whereas isolated K1 and N domains showed a weak or a complete lack of agonistic activity respectively. Starting from these structural and biological observations, we investigated whether it was possible to recapitulate the biological properties of NK1 using a new molecular architecture of isolated N or K1 domains. Therefore, we engineered multivalent N or K1 scaffolds by combining synthetic and homogeneous site-specifically biotinylated N and K1 domains (NB and K1B) and streptavidin (S). NB alone or in complex failed to activate MET signaling and to trigger cellular phenotypes. Importantly and to the contrary of K1B alone, the semi-synthetic K1B/S complex mimicked NK1 MET agonist activity in cell scattering, morphogenesis and survival phenotypic assays. Impressively, K1B/S complex stimulated in vivo angiogenesis and, when injected in mice, protected the liver against fulminant hepatitis in a MET dependent manner whereas NK1 and HGF were substantially less potent. These data reveal that without N domain, proper multimerization of K1 domain is a promising strategy for the rational design of powerful MET agonists.

  19. Photoswitchable Janus glycodendrimer micelles as multivalent inhibitors of LecA and LecB from Pseudomonas aeruginosa.

    PubMed

    Hu, Yingxue; Beshr, Ghamdan; Garvey, Christopher J; Tabor, Rico F; Titz, Alexander; Wilkinson, Brendan L

    2017-11-01

    The first example of the self-assembly and lectin binding properties of photoswitchable glycodendrimer micelles is reported. Light-addressable micelles were assembled from a library of 12 amphiphilic Janus glycodendrimers composed of variable carbohydrate head groups and hydrophobic tail groups linked to an azobenzene core. Spontaneous association in water gave cylindrical micelles with uniform size distribution as determined by dynamic light scattering (DLS) and small angle neutron scattering (SANS). Trans-cis photoisomerization of the azobenzene dendrimer core was used to probe the self-assembly behaviour and lectin binding properties of cylindrical micelles, revealing moderate-to-potent inhibition of lectins LecA and LecB from Pseudomonas aeruginosa. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  20. The impact of circular migration on a village economy.

    PubMed

    Hetler, C B

    1989-04-01

    The author examines the economy of a rural village in Indonesia in which a high proportion of households rely on remittances from urban informal sector earnings. Household income and per capita income are analyzed according to whether or not households have at least one temporary migrant, and by the sex and age of the household head. Findings indicate that "remittances from short-term circular migration push many households into the middle and upper income ranges. However, the wealthiest households continue to rely on traditional high earning activities and do not depend on remittances. The poorest households are scattered among those who rely on remittances and those still totally dependent upon traditional low earning village activities, regardless of the sex and age of the household head." excerpt

  1. Is a Preoperative Gastrointestinal Endoscopy for Second Primary Cancer Detection in Head and Neck Cancer Necessary? Ten-year Registry Data.

    PubMed

    Heo, Gyeong Mi; Kim, Mi Hee; Kim, Jin Hwan; Rho, Young Soo; Shin, Woon Geon

    2016-07-25

    In head and neck squamous cell carcinoma, second primary gastrointestinal tumors are not uncommon. However, it is unclear whether a screening endoscopy is needed for detecting gastrointestinal neoplasm in patients with head and neck cancer. Therefore, we analyzed the prevalence and independent risk factors for second primary gastrointestinal neoplasm in head and neck squamous cell carcinoma. A consecutive series of 328 patients with primary head and neck squamous cell carcinoma that underwent esophagogastroduodenoscopy or colonoscopy were included using our registry. An age- and sex-matched group of 328 control subjects was enrolled. We assessed risk factors of synchronous gastrointestinal cancer. The prevalence of esophageal cancer with head and neck squamous cell carcinoma was significantly higher than that of the control group (1.5% vs. 0.0%, p=0.011). An age of 54 years or more (OR, 1.033; 95% CI, 1.008-1.059; p=0.009) and male gender (OR, 4.974; 95% CI, 1.648-15.013; p=0.004) were risk factors for concomitant colorectal cancer or adenomas in the head and neck squamous cell carcinoma patients. Preoperative colonoscopy can be recommended for detecting synchronous second primary colorectal lesions in head and neck squamous cell carcinoma patients with male sex regardless of age, and esophagogastroduodenoscopy is necessary in all head and neck squamous cell carcinoma patients for detecting esophageal cancer.

  2. The natural history of Perthes' disease

    PubMed Central

    2010-01-01

    Background The prognosis in Perthes' disease varies considerably according to certain risk factors, but there is no concensus regarding the relative importance of these factors. We assessed the natural history of the disease and defined prognostic factors of value in deciding the proper treatment. Patients and methods During the 5-year period 1996–2000, a nationwide study on Perthes' disease was performed in Norway. 425 patients were registered. The present study involved the 212 children (mean age 5.1 years, 77% boys) who were affected unilaterally and who had been treated with physiotherapy only (which is considered not to change the natural history). They were followed by taking radiographs at the time of diagnosis and after 1, 3, and 5 years. At the 5-year follow-up, the outcome was evaluated according to a modification of the Stulberg classification: good (spherical femoral head), fair (ovoid femoral head), and poor (flat femoral head). Results The 5-year radiographic results were strongly dependent on 4 risk factors: age 6 years or more at diagnosis, total femoral head necrosis, height of the lateral pillar of the epiphysis less than 50% of normal height, and femoral head cover less than 80%. As the number of risk factors increased from 0 to 4, the proportion of patients with good radiographic 5-year outcome decreased from 79% to 0% and the proportion with poor outcome increased from 3% to 91%. Interpretation Most children under 6 years of age do not need any special treatment. In older children, no special treatment is indicated if the whole femoral head is not necrotic and the femoral head cover is > 80%. In the most severe forms of the disease (i.e. more than 2 risk factors), surgical containment treatment seems advisable. PMID:21067434

  3. The natural history of Perthes' disease.

    PubMed

    Terjesen, Terje; Wiig, Ola; Svenningsen, Svein

    2010-12-01

    The prognosis in Perthes' disease varies considerably according to certain risk factors, but there is no concensus regarding the relative importance of these factors. We assessed the natural history of the disease and defined prognostic factors of value in deciding the proper treatment. During the 5-year period 1996-2000, a nationwide study on Perthes' disease was performed in Norway. 425 patients were registered. The present study involved the 212 children (mean age 5.1 years, 77% boys) who were affected unilaterally and who had been treated with physiotherapy only (which is considered not to change the natural history). They were followed by taking radiographs at the time of diagnosis and after 1, 3, and 5 years. At the 5-year follow-up, the outcome was evaluated according to a modification of the Stulberg classification: good (spherical femoral head), fair (ovoid femoral head), and poor (flat femoral head). The 5-year radiographic results were strongly dependent on 4 risk factors: age 6 years or more at diagnosis, total femoral head necrosis, height of the lateral pillar of the epiphysis less than 50% of normal height, and femoral head cover less than 80%. As the number of risk factors increased from 0 to 4, the proportion of patients with good radiographic 5-year outcome decreased from 79% to 0% and the proportion with poor outcome increased from 3% to 91%. Most children under 6 years of age do not need any special treatment. In older children, no special treatment is indicated if the whole femoral head is not necrotic and the femoral head cover is > 80%. In the most severe forms of the disease (i.e. more than 2 risk factors), surgical containment treatment seems advisable.

  4. Formation of the Embryonic Head in the Mouse: Attributes of a Gene Regulatory Network.

    PubMed

    Tam, Patrick P L; Fossat, Nicolas; Wilkie, Emilie; Loebel, David A F; Ip, Chi Kin; Ramialison, Mirana

    2016-01-01

    The embryonic head is the first major body part to be constructed during embryogenesis. The allocation and the assembly of the progenitor tissues, which start at gastrulation, are accompanied by the spatiotemporal activity of transcription factors and signaling pathways that drives lineage specification, germ layer formation, and cell/tissue movement. The morphogenesis, regionalization, and patterning of the brain and craniofacial structures rely on the function of LIM-domain, homeodomain, and basic helix-loop-helix transcription factors. These factors constitute the central nodes of a gene regulatory network (GRN) which encompasses and intersects with signaling pathways involved with head formation. It is predicted that the functional output of this "head GRN" impacts on cellular function and cell-cell interactions that are essential for lineage differentiation and tissue modeling, which are key processes underpinning the formation of the head. © 2016 Elsevier Inc. All rights reserved.

  5. Dynamics of lipid saccharide nanoparticles by quasielastic neutron scattering

    NASA Astrophysics Data System (ADS)

    Di Bari, M. T.; Gerelli, Y.; Sonvico, F.; Deriu, A.; Cavatorta, F.; Albanese, G.; Colombo, P.; Fernandez-Alonso, F.

    2008-04-01

    Nano- and microparticles composed of saccharide and lipid systems are extensively investigated for applications as highly biocompatible drug carriers. A detailed understanding of particle-solvent interactions is of key importance in order to tailor their characteristics for delivering drugs with specific chemical properties. Here we report results of a quasielastic neutron scattering (QENS) investigation on lecithin/chitosan nanoparticles prepared by autoassembling the two components in an aqueous solution. The measurements were performed at room temperature on lyophilized and H 2O hydrated nanoparticles ( h = 0.47 w H 2O/w hydrated sample). In the latter, hydration water is mostly enclosed inside the nanoparticles; its dynamics is similar to that of bulk water but with a significant decrease in diffusivity. The scattering from the nanoparticles can be described by a simple model of confined diffusion. In the lyophilized state only hydrogens belonging to the polar heads are seen as mobile within the experimental time-window. In the hydrated sample the diffusive dynamics involves also a significant part of the hydrogens in the lipid tails.

  6. General synthesis and physicochemical characterisation of a series of peptide-mimic lysine-based amino-functionalised lipids.

    PubMed

    Wölk, Christian; Drescher, Simon; Meister, Annette; Blume, Alfred; Langner, Andreas; Dobner, Bodo

    2013-09-16

    A series of novel malonic acid diamides (second generation) with two long hydrophobic alkyl chains and an alkaline polar head group was synthesised and characterised as a new class of amino-functionalised lipids. These peptide-mimic lipids are suitable for polynucleotide transfer. The lipids bear a novel backbone consisting of a lysine unit and a malonic acid unit. Six different head-group structures, which vary in size and number of amino groups that can be protonated, were attached to the backbone structure. Furthermore, different alkyl chains were used to build the lipophilic part (namely tetradecyl, hexadecyl, and oleyl). Phase transitions of the new compounds in aqueous dispersions at pH 10 were analysed and discussed in terms of head group and alkyl chain variations. The shape and size of the formed aggregates of selected lipid dispersions were investigated by dynamic light scattering and transmission electron microscopy. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Dropped-head in recessive oculopharyngeal muscular dystrophy.

    PubMed

    Garibaldi, Matteo; Pennisi, Elena Maria; Bruttini, Mirella; Bizzarri, Veronica; Bucci, Elisabetta; Morino, Stefania; Talerico, Caterina; Stoppacciaro, Antonella; Renieri, Alessandra; Antonini, Giovanni

    2015-11-01

    A 69-year-old woman presented a dropped head, caused by severe neck extensor weakness that had started two years before. She had also developed a mild degree of dysphagia, rhinolalia, eyelid ptosis and proximal limb weakness during the last months. EMG revealed myopathic changes. Muscle MRI detected fatty infiltration in the posterior neck muscles and tongue. Muscle biopsy revealed fiber size variations, sporadic rimmed vacuoles, small scattered angulated fibers and a patchy myofibrillar network. Genetic analysis revealed homozygous (GCN)11 expansions in the PABPN1 gene that were consistent with recessive oculopharyngeal muscular dystrophy (OPMD). There are a few reports of the recessive form, which has a later disease onset with milder symptoms and higher clinical variability than the typical dominantly inherited form. This patient, who is the first Italian and the eighth worldwide reported case of recessive OPMD, is also the first case of OPMD with dropped-head syndrome, which thus expands the clinical phenotype of recessive OPMD. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Correction of autofluorescence intensity for epithelial scattering by optical coherence tomography: a phantom study

    NASA Astrophysics Data System (ADS)

    Pahlevaninezhad, H.; Lee, A. M. D.; Hyun, C.; Lam, S.; MacAulay, C.; Lane, P. M.

    2013-03-01

    In this paper, we conduct a phantom study for modeling the autofluorescence (AF) properties of tissue. A combined optical coherence tomography (OCT) and AF imaging system is proposed to measure the strength of the AF signal in terms of the scattering layer thickness and concentration. The combined AF-OCT system is capable of estimating the AF loss due to scattering in the epithelium using the thickness and scattering concentration calculated from the co-registered OCT images. We define a correction factor to account for scattering losses in the epithelium and calculate a scatteringcorrected AF signal. We believe the scattering-corrected AF will reduce the diagnostic false-positives rate in the early detection of airway lesions due to confounding factors such as increased epithelial thickness and inflammations.

  9. Head Pose Estimation Using Multilinear Subspace Analysis for Robot Human Awareness

    NASA Technical Reports Server (NTRS)

    Ivanov, Tonislav; Matthies, Larry; Vasilescu, M. Alex O.

    2009-01-01

    Mobile robots, operating in unconstrained indoor and outdoor environments, would benefit in many ways from perception of the human awareness around them. Knowledge of people's head pose and gaze directions would enable the robot to deduce which people are aware of the its presence, and to predict future motions of the people for better path planning. To make such inferences, requires estimating head pose on facial images that are combination of multiple varying factors, such as identity, appearance, head pose, and illumination. By applying multilinear algebra, the algebra of higher-order tensors, we can separate these factors and estimate head pose regardless of subject's identity or image conditions. Furthermore, we can automatically handle uncertainty in the size of the face and its location. We demonstrate a pipeline of on-the-move detection of pedestrians with a robot stereo vision system, segmentation of the head, and head pose estimation in cluttered urban street scenes.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org

    Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according tomore » measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.« less

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, A; Pasciak, A; Wagner, L

    Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluationsmore » studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.« less

  12. Heading in Soccer: Integral Skill or Grounds for Cognitive Dysfunction?

    ERIC Educational Resources Information Center

    Kirkendall, Donald T.; Garrett, William E., Jr.

    2001-01-01

    Discusses how purposeful heading of soccer balls and head injuries affect soccer players' cognitive dysfunction. Cognitive deficits may occur for many reasons. Heading cannot be blamed when details of the actual event and impact are unknown. Concussions are the most common head injury in soccer and a factor in cognitive deficits and are probably…

  13. Extrinsic extinction cross-section in the multiple acoustic scattering by fluid particles

    NASA Astrophysics Data System (ADS)

    Mitri, F. G.

    2017-04-01

    Cross-sections (and their related energy efficiency factors) are physical parameters used in the quantitative analysis of different phenomena arising from the interaction of waves with a particle (or multiple particles). Earlier works with the acoustic scattering theory considered such quadratic (i.e., nonlinear) quantities for a single scatterer, although a few extended the formalism for a pair of scatterers but were limited to the scattering cross-section only. Therefore, the standard formalism applied to viscous particles is not suitable for the complete description of the cross-sections and energy balance of the multiple-particle system because both absorption and extinction phenomena arise during the multiple scattering process. Based upon the law of the conservation of energy, this work provides a complete comprehensive analysis for the extrinsic scattering, absorption, and extinction cross-sections (i.e., in the far-field) of a pair of viscous scatterers of arbitrary shape, immersed in a nonviscous isotropic fluid. A law of acoustic extinction taking into consideration interparticle effects in wave propagation is established, which constitutes a generalized form of the optical theorem in multiple scattering. Analytical expressions for the scattering, absorption, and extinction cross-sections are derived for plane progressive waves with arbitrary incidence. The mathematical expressions are formulated in partial-wave series expansions in cylindrical coordinates involving the angle of incidence, the addition theorem for the cylindrical wave functions, and the expansion coefficients of the scatterers. The analysis shows that the multiple scattering cross-section depends upon the expansion coefficients of both scatterers in addition to an interference factor that depends on the interparticle distance. However, the extinction cross-section depends on the expansion coefficients of the scatterer located in a particular system of coordinates, in addition to the interference term. Numerical examples illustrate the analysis for two viscous fluid circular cylindrical cross-sections immersed in a non-viscous fluid. Computations for the (non-dimensional) scattering, absorption, and extinction cross-section factors are performed with particular emphasis on varying the angle of incidence, the interparticle distance, and the sizes, and the physical properties of the particles. A symmetric behavior is observed for the dimensionless multiple scattering cross-section, while asymmetries arise for both the dimensionless absorption and extinction cross-sections with respect to the angle of incidence. The present analysis provides a complete analytical and computational method for the prediction of cross-section and energy efficiency factors in multiple acoustic scattering of plane waves of arbitrary incidence by a pair of scatterers. The results can be used as a priori information in the direct or inverse characterization of multiple scattering systems such as acoustically engineered fluid metamaterials with reconfigurable periodicities, cloaking devices, liquid crystals, and other applications.

  14. Dose comparison between conventional and quasi-monochromatic systems for diagnostic radiology

    NASA Astrophysics Data System (ADS)

    Baldelli, P.; Taibi, A.; Tuffanelli, A.; Gambaccini, M.

    2004-09-01

    Several techniques have been introduced in the last year to reduce the dose to the patient by minimizing the risk of tumour induced by radiation. In this work the radiological potential of dose reduction in quasi-monochromatic spectra produced via mosaic crystal Bragg diffraction has been evaluated, and a comparison with conventional spectra has been performed for four standard examinations: head, chest, abdomen and lumbar sacral spine. We have simulated quasi-monochromatic x-rays with the Shadow code, and conventional spectra with the Spectrum Processor. By means of the PCXMC software, we have simulated four examinations according to parameters established by the European Guidelines, and calculated absorbed dose for principal organs and the effective dose. Simulations of quasi-monochromatic laminar beams have been performed without anti-scatter grid, because of their inherent scatter geometry, and compared with simulations with conventional beams with anti-scatter grids. Results have shown that the dose reduction due to the introduction of quasi-monochromatic x-rays depends on different parameters related to the quality of the beam, the organ composition and the anti-scatter grid. With parameters chosen in this study a significant dose reduction can be achieved for two out of four kinds of examination.

  15. Application of spatially modulated near-infrared structured light to study changes in optical properties of mouse brain tissue during heatstress.

    PubMed

    Shaul, Oren; Fanrazi-Kahana, Michal; Meitav, Omri; Pinhasi, Gad A; Abookasis, David

    2017-11-10

    Heat stress (HS) is a medical emergency defined by abnormally elevated body temperature that causes biochemical, physiological, and hematological changes. The goal of the present research was to detect variations in optical properties (absorption, reduced scattering, and refractive index coefficients) of mouse brain tissue during HS by using near-infrared (NIR) spatial light modulation. NIR spatial patterns with different spatial phases were used to differentiate the effects of tissue scattering from those of absorption. Decoupling optical scattering from absorption enabled the quantification of a tissue's chemical constituents (related to light absorption) and structural properties (related to light scattering). Technically, structured light patterns at low and high spatial frequencies of six wavelengths ranging between 690 and 970 nm were projected onto the mouse scalp surface while diffuse reflected light was recorded by a CCD camera positioned perpendicular to the mouse scalp. Concurrently to pattern projection, brain temperature was measured with a thermal camera positioned slightly off angle from the mouse head while core body temperature was monitored by thermocouple probe. Data analysis demonstrated variations from baseline measurements in a battery of intrinsic brain properties following HS.

  16. Performance studies towards a TOF-PET sensor using Compton scattering at plastic scintillators

    NASA Astrophysics Data System (ADS)

    Kuramoto, M.; Nakamori, T.; Gunji, S.; Kamada, K.; Shoji, Y.; Yoshikawa, A.; Aoki, T.

    2018-01-01

    We have developed a sensor head for a time-of-flight (TOF) PET scanner using plastic scintillators that have a very fast timing property. Given the very small cross section of photoelectric absorption in plastic scintillators at 511 keV, we use Compton scattering in order to compensate for detection efficiency. The detector will consist of two layers of scatterers and absorbers which are made of plastic and inorganic scintillators such as GAGG:Ce, respectively. Signals are read by monolithic Multi Pixel Photon Counters, and with energy deposits and interaction time stamps are being acquired. The scintillators are built to be capable of resolving interaction position in three dimensions, so that our system has also a function of depth-of-interaction (DOI) PET scanners. TOF resolution of ~ 200 ps (FWHM) is achieved in both cases of using the leading-edge discriminator and time-walk correction and using a configuration sensitive to DOI. Both the position resolution and spectroscopy are demonstrated using the prototype data acquisition system, with Compton scattering events subsequently being obtained. We also demonstrated that the background rejection technique using the Compton cone constraint could be valid with our system.

  17. Plane-dependent ML scatter scaling: 3D extension of the 2D simulated single scatter (SSS) estimate

    NASA Astrophysics Data System (ADS)

    Rezaei, Ahmadreza; Salvo, Koen; Vahle, Thomas; Panin, Vladimir; Casey, Michael; Boada, Fernando; Defrise, Michel; Nuyts, Johan

    2017-08-01

    Scatter correction is typically done using a simulation of the single scatter, which is then scaled to account for multiple scatters and other possible model mismatches. This scaling factor is determined by fitting the simulated scatter sinogram to the measured sinogram, using only counts measured along LORs that do not intersect the patient body, i.e. ‘scatter-tails’. Extending previous work, we propose to scale the scatter with a plane dependent factor, which is determined as an additional unknown in the maximum likelihood (ML) reconstructions, using counts in the entire sinogram rather than only the ‘scatter-tails’. The ML-scaled scatter estimates are validated using a Monte-Carlo simulation of a NEMA-like phantom, a phantom scan with typical contrast ratios of a 68Ga-PSMA scan, and 23 whole-body 18F-FDG patient scans. On average, we observe a 12.2% change in the total amount of tracer activity of the MLEM reconstructions of our whole-body patient database when the proposed ML scatter scales are used. Furthermore, reconstructions using the ML-scaled scatter estimates are found to eliminate the typical ‘halo’ artifacts that are often observed in the vicinity of high focal uptake regions.

  18. Electron scattering intensities and Patterson functions of Skyrmions

    NASA Astrophysics Data System (ADS)

    Karliner, M.; King, C.; Manton, N. S.

    2016-06-01

    The scattering of electrons off nuclei is one of the best methods of probing nuclear structure. In this paper we focus on electron scattering off nuclei with spin and isospin zero within the Skyrme model. We consider two distinct methods and simplify our calculations by use of the Born approximation. The first method is to calculate the form factor of the spherically averaged Skyrmion charge density; the second uses the Patterson function to calculate the scattering intensity off randomly oriented Skyrmions, and spherically averages at the end. We compare our findings with experimental scattering data. We also find approximate analytical formulae for the first zero and first stationary point of a form factor.

  19. Numerical Investigation on Head and Brain Injuries Caused by Windshield Impact on Riders Using Electric Self-Balancing Scooters

    PubMed Central

    Zheng, Yanting; Shen, Ming; Yang, Xianfeng

    2018-01-01

    To investigate head-brain injuries caused by windshield impact on riders using electric self-balancing scooters (ESS). Numerical vehicle ESS crash scenarios are constructed by combining the finite element (FE) vehicle model and multibody scooter/rider models. Impact kinematic postures of the head-windshield contact under various impact conditions are captured. Then, the processes during head-windshield contact are reconstructed using validated FE head/laminated windshield models to assess the severity of brain injury caused by the head-windshield contact. Governing factors, such as vehicle speed, ESS speed, and the initial orientation of ESS rider, have nontrivial influences over the severity of a rider's brain injuries. Results also show positive correlations between vehicle speed and head-windshield impact speeds (linear and angular). Meanwhile, the time of head-windshield contact happens earlier when the vehicle speed is faster. According to the intensive study, windshield-head contact speed (linear and angular), impact location on the windshield, and head collision area are found to be direct factors on ESS riders' brain injuries during an impact. The von Mises stress and shear stress rise when relative contact speed of head-windshield increases. Brain injury indices vary widely when the head impacting the windshield from center to the edge or impacting with different areas. PMID:29770161

  20. Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses.

    PubMed

    Huda, Walter; Lieberman, Kristin A; Chang, Jack; Roskopf, Marsha L

    2004-03-01

    We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18 x 7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186+/-8 mm and 147+/-8 mm, respectively, with an average HU value of 209+/-40. An infant head was found to be equivalent to a water cylinder with a radius of approximately 60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is approximately 20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors.

  1. Thermoelectric power factor enhancement by ionized nanoparticle scattering

    NASA Astrophysics Data System (ADS)

    Bahk, Je-Hyeong; Bian, Zhixi; Zebarjadi, Mona; Santhanam, Parthiban; Ram, Rajeev; Shakouri, Ali

    2011-08-01

    We show theoretically that the thermoelectric power factor can be enhanced in degenerate semiconductors when embedded nanoparticles donate carriers to the matrix and replace conventional impurity dopants as scattering centers. Nanoparticle scattering rates calculated by the partial wave method indicate a mobility enhancement over materials with equivalent doping by isolated ionized impurities while the Seebeck coefficient remains nearly intact. We find that the thermoelectric power factor of In0.53Ga0.47As from 300 K to 800 K is enhanced by 15% - 30% by nanoparticles 3-4 nm in diameter.

  2. Notes on breeding sharp-shinned hawks and cooper’s hawks in Barnwell County, South Carolina

    Treesearch

    Mark Vukovich; John C. Kilgo

    2009-01-01

    Breeding records of Accipiter striatus (Sharp-shinned Hawks) in the southeastern US are scattered and isolated. We documented a Sharp-shinned Hawk and Accipiter cooperii (Cooper’s Hawk) nest while conducting a telemetry study on Melanerpes erythrocephalus (Red-headed Woodpeckers) in Barnwell County, SC in 2006 and 2007. We report the first known nest of a Sharp-shinned...

  3. Modeling of Diffuse-Diffuse Photon Coupling via a Nonscattering Region: a Comparative Study

    NASA Astrophysics Data System (ADS)

    Lee, Jae Hoon; Kim, Seunghwan; Kim, Youn Tae

    2004-06-01

    It is well established that diffusion approximation is valid for light propagation in highly scattering media, but it breaks down in nonscattering regions. The previous methods that manipulate nonscattering regions are essentially boundary-to-boundary coupling (BBC) methods through a nonscattering void region based on the radiosity theory. We present a boundary-to-interior coupling (BIC) method. BIC is based on the fact that the collimated pencil beam incident on the medium can be replaced by an isotropic point source positioned at one reduced scattering length inside the medium from an illuminated point. A similar replacement is possible for the nondiffuse lights that enter the diffuse medium through the void, and it is formulated as the BIC method. We implemented both coupling methods using the finite element method (FEM) and tested for the circle with a void gap and for a four-layer adult head model. For mean time of flight, the BIC shows better agreement with Monte Carlo (MC) simulation results than BBC. For intensity, BIC shows a comparable match with MC data compared with that of BBC. The effect of absorption of the clear layer in the adult head model was investigated. Both mean time and intensity decrease as absorption of the clear layer increases.

  4. Modeling of diffuse-diffuse photon coupling via a nonscattering region: a comparative study.

    PubMed

    Lee, Jae Hoon; Kim, Seunghwan; Kim, Youn Tae

    2004-06-20

    It is well established that diffusion approximation is valid for light propagation in highly scattering media, but it breaks down in nonscattering regions. The previous methods that manipulate nonscattering regions are essentially boundary-to-boundary coupling (BBC) methods through a nonscattering void region based on the radiosity theory. We present a boundary-to-interior coupling (BIC) method. BIC is based on the fact that the collimated pencil beam incident on the medium can be replaced by an isotropic point source positioned at one reduced scattering length inside the medium from an illuminated point. A similar replacement is possible for the nondiffuse lights that enter the diffuse medium through the void, and it is formulated as the BIC method. We implemented both coupling methods using the finite element method (FEM) and tested for the circle with a void gap and for a four-layer adult head model. For mean time of flight, the BIC shows better agreement with Monte Carlo (MC) simulation results than BBC. For intensity, BIC shows a comparable match with MC data compared with that of BBC. The effect of absorption of the clear layer in the adult head model was investigated. Both mean time and intensity decrease as absorption of the clear layer increases.

  5. Hybrid graphene-copper UWB array sensor for brain tumor detection via scattering parameters in microwave detection system

    NASA Astrophysics Data System (ADS)

    Jamlos, Mohd Aminudin; Ismail, Abdul Hafiizh; Jamlos, Mohd Faizal; Narbudowicz, Adam

    2017-01-01

    Hybrid graphene-copper ultra-wideband array sensor applied to microwave imaging technique is successfully used in detecting and visualizing tumor inside human brain. The sensor made of graphene coated film for the patch while copper for both the transmission line and parasitic element. The hybrid sensor performance is better than fully copper sensor. Hybrid sensor recorded wider bandwidth of 2.0-10.1 GHz compared with fully copper sensor operated from 2.5 to 10.1 GHz. Higher gain of 3.8-8.5 dB is presented by hybrid sensor, while fully copper sensor stated lower gain ranging from 2.6 to 6.7 dB. Both sensors recorded excellent total efficiency averaged at 97 and 94%, respectively. The sensor used for both transmits equivalent signal and receives backscattering signal from stratified human head model in detecting tumor. Difference in the data of the scattering parameters recorded from the head model with presence and absence of tumor is used as the main data to be further processed in confocal microwave imaging algorithm in generating image. MATLAB software is utilized to analyze S-parameter signals obtained from measurement. Tumor presence is indicated by lower S-parameter values compared to higher values recorded by tumor absence.

  6. Logistic regression analysis of factors associated with avascular necrosis of the femoral head following femoral neck fractures in middle-aged and elderly patients.

    PubMed

    Ai, Zi-Sheng; Gao, You-Shui; Sun, Yuan; Liu, Yue; Zhang, Chang-Qing; Jiang, Cheng-Hua

    2013-03-01

    Risk factors for femoral neck fracture-induced avascular necrosis of the femoral head have not been elucidated clearly in middle-aged and elderly patients. Moreover, the high incidence of screw removal in China and its effect on the fate of the involved femoral head require statistical methods to reflect their intrinsic relationship. Ninety-nine patients older than 45 years with femoral neck fracture were treated by internal fixation between May 1999 and April 2004. Descriptive analysis, interaction analysis between associated factors, single factor logistic regression, multivariate logistic regression, and detailed interaction analysis were employed to explore potential relationships among associated factors. Avascular necrosis of the femoral head was found in 15 cases (15.2 %). Age × the status of implants (removal vs. maintenance) and gender × the timing of reduction were interactive according to two-factor interactive analysis. Age, the displacement of fractures, the quality of reduction, and the status of implants were found to be significant factors in single factor logistic regression analysis. Age, age × the status of implants, and the quality of reduction were found to be significant factors in multivariate logistic regression analysis. In fine interaction analysis after multivariate logistic regression analysis, implant removal was the most important risk factor for avascular necrosis in 56-to-85-year-old patients, with a risk ratio of 26.00 (95 % CI = 3.076-219.747). The middle-aged and elderly have less incidence of avascular necrosis of the femoral head following femoral neck fractures treated by cannulated screws. The removal of cannulated screws can induce a significantly high incidence of avascular necrosis of the femoral head in elderly patients, while a high-quality reduction is helpful to reduce avascular necrosis.

  7. Density Resolution Artifacts Encountered When Scanning Infant Heads With X-Ray Computed Tomography (CT)

    NASA Astrophysics Data System (ADS)

    Thompson, Joseph R.; M oore, Robert J.; Hinshaw, David B.; Hasso, Anton N.

    1982-12-01

    Density resolution the accuracy of CT numbers) is generally recognized by radiologists w'ao interpret Children's, CT to be very poor. A CT scanning phantom was made. in order to document the brain attenuation inaccuracies which do occur and also to derive normal brain attenuation values for varying sized heads, given. the skull diameters and thicknesses. In scanning' this phantom, other factors, some of equal importance, to small head size, were found to affect the Hounsfield numbers of brain. The phantom was scanned in order to determine the magnitude of these specific factors, using the GE 8800 model scanner. After head size (412 to 25, H), the variables of the head support (up to 15 H) and centering within the field of view (6-23 H) were of similar importance, for small heads. Kilovoltage, software, and machine drift were less, important, although only kVp settings, of 105 and 120 were employed. Manufacturers may improve CT number accuracy if they recognize the relative, magnitude of the various factors which alter measured attenuation.

  8. Risk factors of recipient site infection in head and neck cancer patients undergoing pectoralis major myocutaneous flap reconstruction.

    PubMed

    Wang, Chao-Hsien; Wong, Yong-Kie; Wang, Ching-Ping; Wang, Chen-Chi; Jiang, Rong-San; Lai, Chih-Sheng; Liu, Shih-An

    2015-11-01

    The aim of this study was to investigate the factors associated with infection at the recipient site of pectoralis major myocutaneous flap (PMMF) of head and neck cancer patients. We retrospectively reviewed head and neck cancer patients who underwent PMMF reconstruction and identified those with recipient site infection. Variables of patients with and without infection were compared and associated factors were investigated by logistic regression model. A total of 478 patients were included in the final analysis and 183 patients (38.3%) developed recipient site infection. Lower margin of skin island, concurrent tracheotomy, diabetes mellitus, mandibular plate reconstruction, prior radiation, and peri-operative blood transfusion were independent factors associated with recipient site infection of PMMF. Skin island of PMMF beyond the eighth intercostal space markedly increased the risk of recipient site infection after major head and neck cancer surgery. Recognition of relevant factors associated with infection may help surgeons to identify those at risk.

  9. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... applicable authorized tank car specification and must be equipped with a head shield as prescribed in § 179... jacket and head shield. When the jacket and head shield are made from any authorized steel with a minimum... jacket and head shield must be increased by a factor of 1.157. Forming allowances for heads are not...

  10. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... applicable authorized tank car specification and must be equipped with a head shield as prescribed in § 179... jacket and head shield. When the jacket and head shield are made from any authorized steel with a minimum... jacket and head shield must be increased by a factor of 1.157. Forming allowances for heads are not...

  11. THE HOUSING ENVIRONMENT AS A FACTOR IN CHILD DEVELOPMENT. FINAL REPORT.

    ERIC Educational Resources Information Center

    RICE, ROBERT R.

    IN KANSAS CITY, MO., 208 NEGRO FIVE YEAR OLDS WERE STUDIED TO EXAMINE THE INFLUENCE OF HOUSING UPON CHILD DEVELOPMENT AND TO COMPARE THE RELATIVE INFLUENCE OF HOUSING ON HEAD START AND NON-HEAD START CHILDREN. FOUR GROUPS OF 52 CHILDREN EACH INCLUDED (1) HEAD START, PUBLIC HOUSING, (2) HEAD START, SLUM HOUSING, (3) NON-HEAD START, PUBLIC HOUSING,…

  12. Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures.

    PubMed

    Wang, Chen; Xu, Gui-Jun; Han, Zhe; Jiang, Xuan; Zhang, Cheng-Bao; Dong, Qiang; Ma, Jian-Xiong; Ma, Xin-Long

    2015-11-01

    The aim of the study was to introduce a new method for measuring the residual displacement of the femoral head after internal fixation and explore the relationship between residual displacement and osteonecrosis with femoral head, and to evaluate the risk factors associated with osteonecrosis of the femoral head in patients with femoral neck fractures treated by closed reduction and percutaneous cannulated screw fixation.One hundred and fifty patients who sustained intracapsular femoral neck fractures between January 2011 and April 2013 were enrolled in the study. All were treated with closed reduction and percutaneous cannulated screw internal fixation. The residual displacement of the femoral head after surgery was measured by 3-dimensional reconstruction that evaluated the quality of the reduction. Other data that might affect prognosis were also obtained from outpatient follow-up, telephone calls, or case reviews. Multivariate logistic regression analysis was applied to assess the intrinsic relationship between the risk factors and the osteonecrosis of the femoral head.Osteonecrosis of the femoral head occurred in 27 patients (18%). Significant differences were observed regarding the residual displacement of the femoral head and the preoperative Garden classification. Moreover, we found more or less residual displacement of femoral head in all patients with high quality of reduction based on x-ray by the new technique. There was a close relationship between residual displacement and ONFH.There exists limitation to evaluate the quality of reduction by x-ray. Three-dimensional reconstruction and digital measurement, as a new method, is a more accurate method to assess the quality of reduction. Residual displacement of the femoral head and the preoperative Garden classification were risk factors for osteonecrosis of the femoral head. High-quality reduction was necessary to avoid complications.

  13. The electron microscope appearance of the subchondral bone plate in the human femoral head in osteoarthritis and osteoporosis

    PubMed Central

    LI, BAOHUA; MARSHALL, DEBORAH; ROE, MARTIN; ASPDEN, RICHARD M.

    1999-01-01

    The subchondral bone plate supports the articular cartilage in diarthrodial joints. It has a significant mechanical function in transmitting loads from the cartilage into the underlying cancellous bone and has been implicated in the destruction of cartilage in osteoarthritis (OA) and its sparing in osteoporosis (OP), but little is known of its composition, structure or material properties. This study investigated the microscopic appearance and mineral composition of the subchondral bone plate in femoral heads from patients with OA or OP to determine how these correspond to changes in composition and stiffness found in other studies. Freeze-fractured full-depth samples of the subchondral bone plate from the femoral heads of patients with osteoarthritis, osteoporosis or a matched control group were examined using back scattered and secondary emission scanning electron microscopy. Other samples were embedded and polished and examined using back-scattered electron microscopy and electron probe microanalysis. The appearances of the samples from the normal and osteoporotic patients were very similar, with the subchondral bone plate overlayed by a layer of calcified cartilage. Osteoporotic samples presented a more uniform fracture surface and the relative thicknesses of the layers appeared to be different. In contrast, the OA bone plate appeared to be porous and have a much more textured surface. There were occasional sites of microtrabecular bone formation between the trabeculae of the underlying cancellous bone, which were not seen in the other groups, and more numerous osteoclast resorption pits. The calcified cartilage layer was almost absent and the bone plate was apparently thickened. The appearance of the osteoarthritic subchondral bone plate was, therefore, considerably different from both the normal and the osteoporotic, strongly indicative of abnormal cellular activity. PMID:10473297

  14. Technical Note: Partial body irradiation of mice using a customized PMMA apparatus and a clinical 3D planning/LINAC radiotherapy system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karagounis, Ilias V.; Koukourakis, Michael I., E-mail: targ@her.forthnet.gr, E-mail: mkoukour@med.duth.gr; Abatzoglou, Ioannis M., E-mail: abadzoglou@yahoo.gr

    Purpose: In vivo radiobiology experiments involving partial body irradiation (PBI) of mice are of major importance because they allow for the evaluation of individual organ tolerance; overcoming current limitations of experiments using lower dose, whole body irradiation. In the current study, the authors characterize and validate an effective and efficient apparatus for multiple animal PBI, directed to the head, thorax, or abdomen of mice. Methods: The apparatus is made of polymethylmethacrylate and consists of a rectangular parallelepiped prism (40 cm × 16 cm × 8 cm), in which five holes were drilled to accomodate standard 60 ml syringes, each housingmore » an unanesthetized, fully immobilized mouse. Following CT-scanning and radiotherapy treatment planning, radiation fields were designed to irradiate the head, thorax, or abdomen of the animal. Thermoluminescent dosimeters (TLDs) were used to confirm the treatment planning dosimetry for primary beam and scattered radiation. Results: Mice are efficiently placed into 60 ml syringes and immobilized, without the use of anesthetics. Although partial rotational movement around the longitudinal axis and a minor 2 mm forward/backward movement are permitted, this does not compromise the irradiation of the chosen body area. TLDs confirmed the dose values predicted by the treatment planning dosimetry, both for primary beam and scattered radiation. Conclusions: The customized PMMA apparatus described and validated is cost-effective, convenient to use, and efficient in performing PBI without the use of anesthesia. The developed apparatus permits the isolated irradiation of the mouse head, thorax, and abdomen. Importantly, the apparatus allows the delivery of PBI to five mice, simultaneously, representing an efficient way to effectively expose a large number of animals to PBI through multiple daily fractions, simulating clinical radiotherapy treatment schedules.« less

  15. Technical Note: Partial body irradiation of mice using a customized PMMA apparatus and a clinical 3D planning/LINAC radiotherapy system.

    PubMed

    Karagounis, Ilias V; Abatzoglou, Ioannis M; Koukourakis, Michael I

    2016-05-01

    In vivo radiobiology experiments involving partial body irradiation (PBI) of mice are of major importance because they allow for the evaluation of individual organ tolerance; overcoming current limitations of experiments using lower dose, whole body irradiation. In the current study, the authors characterize and validate an effective and efficient apparatus for multiple animal PBI, directed to the head, thorax, or abdomen of mice. The apparatus is made of polymethylmethacrylate and consists of a rectangular parallelepiped prism (40 cm × 16 cm × 8 cm), in which five holes were drilled to accomodate standard 60 ml syringes, each housing an unanesthetized, fully immobilized mouse. Following CT-scanning and radiotherapy treatment planning, radiation fields were designed to irradiate the head, thorax, or abdomen of the animal. Thermoluminescent dosimeters (TLDs) were used to confirm the treatment planning dosimetry for primary beam and scattered radiation. Mice are efficiently placed into 60 ml syringes and immobilized, without the use of anesthetics. Although partial rotational movement around the longitudinal axis and a minor 2 mm forward/backward movement are permitted, this does not compromise the irradiation of the chosen body area. TLDs confirmed the dose values predicted by the treatment planning dosimetry, both for primary beam and scattered radiation. The customized PMMA apparatus described and validated is cost-effective, convenient to use, and efficient in performing PBI without the use of anesthesia. The developed apparatus permits the isolated irradiation of the mouse head, thorax, and abdomen. Importantly, the apparatus allows the delivery of PBI to five mice, simultaneously, representing an efficient way to effectively expose a large number of animals to PBI through multiple daily fractions, simulating clinical radiotherapy treatment schedules.

  16. Factors Influencing Helmet Use, Head Injury, and Hospitalization Among Children Involved in Skateboarding and Snowboarding Accidents.

    PubMed

    Sadeghian, Homa; Nguyen, Brian; Huynh, Nhan; Rouch, Joshua; Lee, Steven L; Bazargan-Hejazi, Shahrzad

    2017-01-01

    Up to 75% of skateboarders and snowboarders admitted to the hospital sustain head injuries. It is unclear why not all children and teenagers wear helmets while snowboarding and skateboarding given the protection they afford. To report on the prevalence of, and factors associated with, skateboarding and snowboarding in injured children and to explore factors that influence helmet use, head injury, and hospitalization in this sample. A cross-sectional study of skateboard- and snowboard-associated injuries from 2003 to 2012 among individuals younger than age 18 years using National Electronic Injury Surveillance System (NEISS) data from approximately 100 hospitals. Helmet use, head injury, and hospitalization. Of 1742 patients in the study, 852 (48.9%) and 890 (51.1%) were skateboarders and snowboarders, respectively. Overall, 907 (52.1%) did not use helmets, and 704 (40.4%) sustained head injuries. Multiple logistic regression analysis showed that age, race/ethnicity, location of boarding, and engaging in skateboarding influenced helmet use. Sex, race/ethnicity, helmet use, and skateboarding predicted head injury. Age, sex, skateboarding, and head injury predicted hospital admission. Statistically significant differences exist in helmet use, head injury, and hospitalization rates between skateboarders and snowboarders. Our findings suggest that injury prevention and outreach programs are needed to increase helmet use and reduce the risk of head injury and hospitalization in skateboarders and other at-risk groups. Further studies are needed to clarify the association between race/ethnicity and helmet use among skateboarders and snowboarders.

  17. Investigation of electron-loss and photon scattering correction factors for FAC-IR-300 ionization chamber

    NASA Astrophysics Data System (ADS)

    Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.

    2017-02-01

    The parallel-plate free-air ionization chamber termed FAC-IR-300 was designed at the Atomic Energy Organization of Iran, AEOI. This chamber is used for low and medium X-ray dosimetry on the primary standard level. In order to evaluate the air-kerma, some correction factors such as electron-loss correction factor (ke) and photon scattering correction factor (ksc) are needed. ke factor corrects the charge loss from the collecting volume and ksc factor corrects the scattering of photons into collecting volume. In this work ke and ksc were estimated by Monte Carlo simulation. These correction factors are calculated for mono-energy photon. As a result of the simulation data, the ke and ksc values for FAC-IR-300 ionization chamber are 1.0704 and 0.9982, respectively.

  18. Quality of life associated factors in head and neck cancer patients in a developing country using the FACT-H&N.

    PubMed

    Bilal, Sobia; Doss, Jennifer Geraldine; Cella, David; Rogers, Simon N

    2015-03-01

    Health-related quality of life (HRQoL) associated factors are vital considerations prior to treatment decision-making for head and neck cancer patients. The study aimed to identify potential socio-demographic and clinical prognostic value of HRQoL in head and neck cancer patients in a developing country. The Functional Assessment of Cancer Therapy-Head and Neck (FACT-H&N)-V4 in Urdu language was administered among 361 head and neck cancer patients. Data were statistically tested through multivariate analysis of variance (MANOVA) and regression modeling to identify the potentially associated factors. Treatment status, tumor stage and tumor site had the strongest negative impact on patients HRQoL, with a statistically significant decrement in FACT summary scales (effect size >0.15). Moderate associated factors of HRQoL included treatment type, marital status, employment status and age (effect size range 0.06-0.15). Weak associated factors of HRQoL with a small effect size (>0.01-0.06) included tumor size and type, gender, education level and ethnicity. This study reports 12 socio-demographic and clinical variables that have a significant impact on HRQoL of head, and neck cancer patients, and that should be considered during treatment decision-making by multidisciplinary teams and also in future HRQoL studies conducted in other developing countries. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. All rights reserved.

  19. Time of elevation of head of bed for patients receiving mechanical ventilation and its related factors.

    PubMed

    Martí-Hereu, L; Arreciado Marañón, A

    The semirecumbent position is a widespread recommendation for the prevention of pneumonia associated with mechanical ventilation. To identify the time of elevation of head of bed for patients under mechanical ventilation and the factors related to such elevation in an intensive care unit. An observational, descriptive cross-sectional study. Conducted in an intensive care unit of a tertiary hospital from April to June 2015. The studied population were mechanically ventilated patients. Daily hours in which patients remained with the head of the bed elevated (≥30°), socio-demographic data and clinical variables were recorded. 261 head elevation measurements were collected. The average daily hours that patients remained at ≥30° was 16h28' (SD ±5h38'), equivalent to 68.6% (SD ±23.5%) of the day. Factors related to elevations ≥30° for longer were: enteral nutrition, levels of deep sedation, cardiac and neurocritical diagnostics. Factors that hindered the position were: sedation levels for agitation and abdominal pathologies. Sex, age and ventilation mode did not show a significant relationship with bed head elevation. Although raising the head of the bed is an easy to perform, economical and measurable preventive measure, its compliance is low due to specific factors specific related o the patient's clinical condition. Using innovations such as continuous measurement of the head position helps to evaluate clinical practice and allows to carry out improvement actions whose impact is beneficial to the patient. Copyright © 2017 Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC). Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Finding electromagnetic and chemical enhancement factors of surface-enhanced Raman scattering.

    PubMed

    Dvoynenko, Mykhaylo M; Wang, Juen-Kai

    2007-12-15

    The authors report two methods to determine electromagnetic and chemical enhancement factors in surface-enhanced Raman scattering (SERS), which are based on saturation property and decay dynamics of photoluminescence and concurrent measurements of photoluminescence and resonance Raman scattering intensities. Considerations for experimental implementation are discussed. This study is expected to facilitate the understanding of SERS mechanisms and the advancement of the usage of SERS in chemical and biological sensor applications.

  1. A fast and pragmatic approach for scatter correction in flat-detector CT using elliptic modeling and iterative optimization

    NASA Astrophysics Data System (ADS)

    Meyer, Michael; Kalender, Willi A.; Kyriakou, Yiannis

    2010-01-01

    Scattered radiation is a major source of artifacts in flat detector computed tomography (FDCT) due to the increased irradiated volumes. We propose a fast projection-based algorithm for correction of scatter artifacts. The presented algorithm combines a convolution method to determine the spatial distribution of the scatter intensity distribution with an object-size-dependent scaling of the scatter intensity distributions using a priori information generated by Monte Carlo simulations. A projection-based (PBSE) and an image-based (IBSE) strategy for size estimation of the scanned object are presented. Both strategies provide good correction and comparable results; the faster PBSE strategy is recommended. Even with such a fast and simple algorithm that in the PBSE variant does not rely on reconstructed volumes or scatter measurements, it is possible to provide a reasonable scatter correction even for truncated scans. For both simulations and measurements, scatter artifacts were significantly reduced and the algorithm showed stable behavior in the z-direction. For simulated voxelized head, hip and thorax phantoms, a figure of merit Q of 0.82, 0.76 and 0.77 was reached, respectively (Q = 0 for uncorrected, Q = 1 for ideal). For a water phantom with 15 cm diameter, for example, a cupping reduction from 10.8% down to 2.1% was achieved. The performance of the correction method has limitations in the case of measurements using non-ideal detectors, intensity calibration, etc. An iterative approach to overcome most of these limitations was proposed. This approach is based on root finding of a cupping metric and may be useful for other scatter correction methods as well. By this optimization, cupping of the measured water phantom was further reduced down to 0.9%. The algorithm was evaluated on a commercial system including truncated and non-homogeneous clinically relevant objects.

  2. Lipid chain geometry of C14 glycerol-based lipids: effect on lipoplex structure and transfection.

    PubMed

    Kudsiova, Laila; Ho, Jimmy; Fridrich, Barbara; Harvey, Richard; Keppler, Melanie; Ng, Tony; Hart, Stephen L; Tabor, Alethea B; Hailes, Helen C; Lawrence, M Jayne

    2011-02-01

    The effects have been determined of a systematic alteration of the alkyl chain geometry of a C14 analogue of DOTMA on the detailed molecular architecture of the resulting cationic vesicles formed both in the absence and presence of 50 mol% DOPE, and of the lipoplexes prepared from these vesicles using either calf thymus or plasmid DNA. The C14 DOTMA analogues studied involved cis- or trans-double bonds at positions Δ9 or Δ11, and a compound (ALK) featuring an alkyne at position C9. For all of these analogues, examination by light scattering and neutron scattering, zeta potential measurement, and negative staining electron microscopy showed that there were no significant differences in the structures or charges of the vesicles or of the resulting lipoplexes, regardless of the nature of the DNA incorporated. Differences were observed, however, between the complexes formed by the various lipids when examining the extent of complexation and release by gel electrophoresis, where the E-lipids appeared to complex the DNA more efficiently than all other lipids tested. Moreover, the lipoplexes prepared from the E-lipids were the most effective in transfection of MDA-MB-231 breast cancer cells. As indicated through confocal microscopy studies, the E-lipids also showed a higher internalisation capacity and a more diffuse cellular distribution, possibly indicating a greater degree of endosomal escape and/or nuclear import. These observations suggest that the extent of complexation is the most important factor in determining the transfection efficiency of the complexes tested. At present it is unclear why the E-lipids were more effective at complexing DNA, although it is thought that the effective area per molecule occupied by the cationic lipid and DOPE head groups, and therefore the density of positive charges on the surface of the bilayer most closely matches the negative charge density of the DNA molecule. From a consideration of the geometry of the cationic lipids it is anticipated that the head groups of the E-lipids would occupy a smaller area per molecule than the ALK or Z-lipids.

  3. Photon spectrum and absorbed dose in brain tumor.

    PubMed

    Vega-Carrillo, Hector Rene; Silva-Sanchez, Angeles; Rivera-Montalvo, Teodoro

    2016-11-01

    Using Monte Carlo methods a BOMAB phantom inside a treatment hall with a brain tumor nearby the pituitary gland was treated with photons produced by a Varian 6MV linac. The photon spectrum and the absorbed dose were calculated in the tumor, pituitary gland and the head. The treatment beam was collimated to illuminate only the tumor volume; however photons were noticed in the gland. Photon fluence reaching the tumor is and 15.7 times larger than the fluence in the pituitary gland, on the other hand the absorbed dose in the tumor is 37.1 times larger than the dose in the gland because photons that reach the pituitary gland are scattered, by the head and the tumor, through Compton effect. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Transverse tensile and stress rupture properties of gamma/gamma prime-delta directionally solidified eutectic

    NASA Technical Reports Server (NTRS)

    Gray, H. H.

    1976-01-01

    Tensile and stress rupture properties were determined primarily at 760 C for specimens oriented at various angles (0 deg, 10 deg, 45 deg, and 90 deg) from the solidification direction of bars and/or slabs of the Ni-20Cb-6Cr-2.5A (gamma/gamma prime-delta) eutectic. Threaded-head specimens yielded longer rupture lives with significantly less scatter than did tapered-head specimens. Miniature specimens are suitable for determining traverse tensile and rupture properties of 1.2 centimeter diameter bar stock. The 300 hour rupture stress at 760 C for specimens oriented at 10 deg from the solidification direction was reduced from 740 to 460 MPa, and to 230 MPa for material oriented at either 45 deg or 90 deg.

  5. Vector and Axial Form Factors Applied to Neutrino Quasielastic Scattering

    NASA Astrophysics Data System (ADS)

    Budd, H.; Bodek, A.; Arrington, J.

    2005-02-01

    We calculate the quasielastic cross sections for neutrino scattering on nucleons using up to date fits to the nucleon elastic electromagnetic form factors GEp, GEn, GMp, GMn, and weak form factors. We show the extraction of F(q). We show the that F(q) has a different contribution to the anti-neutrino cross section, and how the anti-neutrino data can be used to check F(q) extracted from neutrino scattering. (Presented by Howard Budd at NuInt04, Mar. 2004, Laboratori Nazionali del Gran Sasso - INFN - Assergi, Italy [ http://nuint04.lngs.infn.it/])

  6. Light Scattering by Gaussian Particles: A Solution with Finite-Difference Time Domain Technique

    NASA Technical Reports Server (NTRS)

    Sun, W.; Nousiainen, T.; Fu, Q.; Loeb, N. G.; Videen, G.; Muinonen, K.

    2003-01-01

    The understanding of single-scattering properties of complex ice crystals has significance in atmospheric radiative transfer and remote-sensing applications. In this work, light scattering by irregularly shaped Gaussian ice crystals is studied with the finite-difference time-domain (FDTD) technique. For given sample particle shapes and size parameters in the resonance region, the scattering phase matrices and asymmetry factors are calculated. It is found that the deformation of the particle surface can significantly smooth the scattering phase functions and slightly reduce the asymmetry factors. The polarization properties of irregular ice crystals are also significantly different from those of spherical cloud particles. These FDTD results could provide a reference for approximate light-scattering models developed for irregular particle shapes and can have potential applications in developing a much simpler practical light scattering model for ice clouds angular-distribution models and for remote sensing of ice clouds and aerosols using polarized light. (copyright) 2003 Elsevier Science Ltd. All rights reserved.

  7. Scattering from phase-separated vesicles. I. An analytical form factor for multiple static domains

    DOE PAGES

    Heberle, Frederick A.; Anghel, Vinicius N. P.; Katsaras, John

    2015-08-18

    This is the first in a series of studies considering elastic scattering from laterally heterogeneous lipid vesicles containing multiple domains. Unique among biophysical tools, small-angle neutron scattering can in principle give detailed information about the size, shape and spatial arrangement of domains. A general theory for scattering from laterally heterogeneous vesicles is presented, and the analytical form factor for static domains with arbitrary spatial configuration is derived, including a simplification for uniformly sized round domains. The validity of the model, including series truncation effects, is assessed by comparison with simulated data obtained from a Monte Carlo method. Several aspects ofmore » the analytical solution for scattering intensity are discussed in the context of small-angle neutron scattering data, including the effect of varying domain size and number, as well as solvent contrast. Finally, the analysis indicates that effects of domain formation are most pronounced when the vesicle's average scattering length density matches that of the surrounding solvent.« less

  8. 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry.

    PubMed

    Wiggins, G C; Triantafyllou, C; Potthast, A; Reykowski, A; Nittka, M; Wald, L L

    2006-07-01

    A 32-channel 3T receive-only phased-array head coil was developed for human brain imaging. The helmet-shaped array was designed to closely fit the head with individual overlapping circular elements arranged in patterns of hexagonal and pentagonal symmetry similar to that of a soccer ball. The signal-to-noise ratio (SNR) and noise amplification (g-factor) in accelerated imaging applications were quantitatively evaluated in phantom and human images and compared with commercially available head coils. The 32-channel coil showed SNR gains of up to 3.5-fold in the cortex and 1.4-fold in the corpus callosum compared to a (larger) commercial eight-channel head coil. The experimentally measured g-factor performance of the helmet array showed significant improvement compared to the eight-channel array (peak g-factor 59% and 26% of the eight-channel values for four- and fivefold acceleration). The performance of the arrays is demonstrated in high-resolution and highly accelerated brain images. Copyright (c) 2006 Wiley-Liss, Inc.

  9. Factors associated with small head circumference at birth among infants born before the 28th week

    PubMed Central

    McElrath, Thomas F.; Allred, Elizabeth N.; Kuban, Karl; Hecht, Jonathan L.; Onderdonk, Andrew; O’Shea, T. Michael; Paneth, Nigel; Leviton, Alan

    2010-01-01

    OBJECTIVE We sought to identify risk factors for congenital microcephaly in extremely low gestational age newborns. STUDY DESIGN Demographic, clinical, and placental characteristics of 1445 infants born before the 28th week were gathered and evaluated for their relationship with congenital microcephaly. RESULTS Almost 10% of newborns (n = 138), rather than the expected 2.2%, had microcephaly defined as a head circumference >2 SD below the median. In multivariable models, microcephaly was associated with nonwhite race, severe intrauterine growth restriction, delivery for preeclampsia, placental infarction, and being female. The risk factors for a head circumference between <1 and >2 SD below the median were similar to those of microcephaly. CONCLUSION Characteristics associated with fetal growth restriction and preeclampsia are among the strongest correlates of microcephaly among children born at extremely low gestational ages. The elevated risk of a small head among nonwhites and females might reflect the lack of appropriate head circumference standards. PMID:20541727

  10. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    PubMed Central

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  11. Extension of geometrical-optics approximation to on-axis Gaussian beam scattering. I. By a spherical particle.

    PubMed

    Xu, Feng; Ren, Kuan Fang; Cai, Xiaoshu

    2006-07-10

    The geometrical-optics approximation of light scattering by a transparent or absorbing spherical particle is extended from plane wave to Gaussian beam incidence. The formulas for the calculation of the phase of each ray and the divergence factor are revised, and the interference of all the emerging rays is taken into account. The extended geometrical-optics approximation (EGOA) permits one to calculate the scattering diagram in all directions from 0 degrees to 180 degrees. The intensities of the scattered field calculated by the EGOA are compared with those calculated by the generalized Lorenz-Mie theory, and good agreement is found. The surface wave effect in Gaussian beam scattering is also qualitatively analyzed by introducing a flux ratio factor. The approach proposed is particularly important to the further extension of the geometrical-optics approximation to the scattering of large spheroidal particles.

  12. Scattering images from autocorrelation functions of P-wave seismic velocity images: the case of Tenerife Island (Canary Islands, Spain)

    NASA Astrophysics Data System (ADS)

    García-Yeguas, A.; Sánchez-Alzola, A.; De Siena, L.; Prudencio, J.; Díaz-Moreno, A.; Ibáñez, J. M.

    2018-03-01

    We present a P-wave scattering image of the volcanic structures under Tenerife Island using the autocorrelation functions of P-wave vertical velocity fluctuations. We have applied a cluster analysis to total quality factor attenuation ( {Q}_t^{-1} ) and scattering quality factor attenuation ( {Q}_{PSc}^{-1} ) images to interpret the structures in terms of intrinsic and scattering attenuation variations on a 2D plane, corresponding to a depth of 2000 m, and check the robustness of the scattering imaging. The results show that scattering patterns are similar to total attenuation patterns in the south of the island. There are two main areas where patterns differ: at Cañadas-Teide-Pico Viejo Complex, high total attenuation and average-to-low scattering values are observed. We interpret the difference as induced by intrinsic attenuation. In the Santiago Ridge Zone (SRZ) region, high scattering values correspond to average total attenuation. In our interpretation, the anomaly is induced by an extended scatterer, geometrically related to the surficial traces of Garachico and El Chinyero historical eruptions and the area of highest seismic activity during the 2004-2008 seismic crises.

  13. An effective field theory for forward scattering and factorization violation

    DOE PAGES

    Rothstein, Ira Z.; Stewart, Iain W.

    2016-08-03

    Starting with QCD, we derive an effective field theory description for forward scattering and factorization violation as part of the soft-collinear effective field theory (SCET) for high energy scattering. These phenomena are mediated by long distance Glauber gluon exchanges, which are static in time, localized in the longitudinal distance, and act as a kernel for forward scattering where |t| << s. In hard scattering, Glauber gluons can induce corrections which invalidate factorization. With SCET, Glauber exchange graphs can be calculated explicitly, and are distinct from graphs involving soft, collinear, or ultrasoft gluons. We derive a complete basis of operators whichmore » describe the leading power effects of Glauber exchange. Key ingredients include regulating light-cone rapidity singularities and subtractions which prevent double counting. Our results include a novel all orders gauge invariant pure glue soft operator which appears between two collinear rapidity sectors. The 1-gluon Feynman rule for the soft operator coincides with the Lipatov vertex, but it also contributes to emissions with ≥ 2 soft gluons. Our Glauber operator basis is derived using tree level and one-loop matching calculations from full QCD to both SCET II and SCET I. The one-loop amplitude’s rapidity renormalization involves mixing of color octet operators and yields gluon Reggeization at the amplitude level. The rapidity renormalization group equation for the leading soft and collinear functions in the forward scattering cross section are each given by the BFKL equation. Various properties of Glauber gluon exchange in the context of both forward scattering and hard scattering factorization are described. For example, we derive an explicit rule for when eikonalization is valid, and provide a direct connection to the picture of multiple Wilson lines crossing a shockwave. In hard scattering operators Glauber subtractions for soft and collinear loop diagrams ensure that we are not sensitive to the directions for soft and collinear Wilson lines. Conversely, certain Glauber interactions can be absorbed into these soft and collinear Wilson lines by taking them to be in specific directions. Finally, we also discuss criteria for factorization violation.« less

  14. An ever-changing ecological battlefield: marijuana cultivation and toxicant use in western forests

    Treesearch

    Craig M. Thompson; Mourad W  Gabriel; Kathryn L. Purcell

    2017-01-01

    Frozen in the act of scavenging dinner, the vulture’s head lay on the fox’s abdomen, covering the hole it had been attempting to enlarge. When biologists pulled the bird away, they found not only a healthy looking, though dead, fox underneath, but also scores of insects scattered around. Less than a mile away the scene was repeated. This time the dead animal...

  15. Mortality prediction of head Abbreviated Injury Score and Glasgow Coma Scale: analysis of 7,764 head injuries.

    PubMed

    Demetriades, Demetrios; Kuncir, Eric; Murray, James; Velmahos, George C; Rhee, Peter; Chan, Linda

    2004-08-01

    We assessed the prognostic value and limitations of Glasgow Coma Scale (GCS) and head Abbreviated Injury Score (AIS) and correlated head AIS with GCS. We studied 7,764 patients with head injuries. Bivariate analysis was performed to examine the relationship of GCS, head AIS, age, gender, and mechanism of injury with mortality. Stepwise logistic regression analysis was used to identify the independent risk factors associated with mortality. The overall mortality in the group of head injury patients with no other major extracranial injuries and no hypotension on admission was 9.3%. Logistic regression analysis identified head AIS, GCS, age, and mechanism of injury as significant independent risk factors of death. The prognostic value of GCS and head AIS was significantly affected by the mechanism of injury and the age of the patient. Patients with similar GCS or head AIS but different mechanisms of injury or ages had significantly different outcomes. The adjusted odds ratio of death in penetrating trauma was 5.2 (3.9, 7.0), p < 0.0001, and in the age group > or = 55 years the adjusted odds ratio was 3.4 (2.6, 4.6), p < 0.0001. There was no correlation between head AIS and GCS (correlation coefficient -0.31). Mechanism of injury and age have a major effect in the predictive value of GCS and head AIS. There is no good correlation between GCS and head AIS.

  16. Head-on crashes on two-way interurban roads: a public health concern in road safety.

    PubMed

    Olabarria, Marta; Santamariña-Rubio, Elena; Marí-Dell'Olmo, Marc; Gotsens, Mercè; Novoa, Ana M; Borrell, Carme; Pérez, Katherine

    2015-09-01

    To describe the magnitude and characteristics of crashes and drivers involved in head-on crashes on two-way interurban roads in Spain between 2007 and 2012, and to identify the factors associated with the likelihood of head-on crashes on these roads compared with other types of crash. A cross-sectional study was conducted using the National Crash Register. The dependent variables were head-on crashes with injury (yes/no) and drivers involved in head-on crashes (yes/no). Factors associated with head-on crashes and with being a driver involved in a head-on crash versus other types of crash were studied using a multivariate robust Poisson regression model to estimate proportion ratios (PR) and confidence intervals (95% CI). There were 9,192 head-on crashes on two-way Spanish interurban roads. A total of 15,412 men and 3,862 women drivers were involved. Compared with other types of crash, head-on collisions were more likely on roads 7 m or more wide, on road sections with curves, narrowings or drop changes, on wet or snowy surfaces, and in twilight conditions. Transgressions committed by drivers involved in head-on crashes were driving in the opposite direction and incorrectly overtaking another vehicle. Factors associated with a lower probability of head-on crashes were the existence of medians (PR=0.57; 95%CI: 0.48-0.68) and a paved shoulder of less than 1.5 meters (PR=0.81; 95%CI: 0.77-0.86) or from 1.5 to 2.45 meters (PR=0.90; 95%CI: 0.84-0.96). This study allowed the characterization of crashes and drivers involved in head-on crashes on two-way interurban roads. The lower probability observed on roads with median strips point to these measures as an effective way to reduce these collisions. Copyright © 2014 SESPAS. Published by Elsevier Espana. All rights reserved.

  17. Risk factors for head injury events in professional rugby union: a video analysis of 464 head injury events to inform proposed injury prevention strategies.

    PubMed

    Tucker, Ross; Raftery, Martin; Kemp, Simon; Brown, James; Fuller, Gordon; Hester, Ben; Cross, Matthew; Quarrie, Ken

    2017-08-01

    The tackle is responsible for the majority of head injuries during rugby union. In order to address head injury risk, risk factors during the tackle must first be identified. This study analysed tackle characteristics in the professional game in order to inform potential interventions. 464 tackles resulting in a head injury assessment (HIA) were analysed in detail, with tackle type, direction, speed, acceleration, nature of head contact and player body position the characteristics of interest. Propensity to cause an HIA was significantly greater for active shoulder tackles, front-on tackles, high speeder tackles and an accelerating tackler. Head contact between a tackler's head and ball carrier's head or shoulder was significantly more likely to cause an HIA than contact below the level of the shoulder (incident rate ratio (IRR) 4.25, 95%-CI 3.38 to 5.35). The tackler experiences the majority (78%) of HIAs when head-to-head contact occurs. An upright tackler was 1.5 times more likely to experience an HIA than a bent at the waist tackler (IRR 1.44, 95% CI 1.18 to 1.76). This study confirms that energy transfer in the tackle is a risk factor for head injury, since direction, type and speed all influence HIA propensity. The study provides evidence that body position and the height of tackles should be a focus for interventions, since lowering height and adopting a bent at the waist body position is associated with reduced risk for both tacklers and ball carriers. To this end, World Rugby has implemented law change based on the present data. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Prevalence of head lice infestation and pediculicidal effect of permethrine shampoo in primary school girls in a low-income area in southeast of Iran.

    PubMed

    Soleimani-Ahmadi, Moussa; Jaberhashemi, Seyed Aghil; Zare, Mehdi; Sanei-Dehkordi, Alireza

    2017-07-24

    Head lice infestation is a common public health problem that is most prevalent in primary school children throughout the world, especially in developing countries including different parts of Iran. This study aimed to determine the prevalence and risk factors associated with head lice infestation and pediculicidal effect of 1% permethrin shampoo in primary schools girls of Bashagard County, one of the low socioeconomic areas in southeast of Iran. In this interventional study six villages with similar demographical situations were selected and randomly assigned into intervention and control areas. In each area 150 girl students aged 7-12 years were selected randomly and screened for head lice infestation by visual scalp examination. In intervention area, treatment efficacy of 1% permethrin shampoo was evaluated via re-examination for infestation after one, two, and three weeks. Pre-tested structured questionnaire was used to collect data on socio-demographic and associated factors of head lice infestation. The prevalence of head lice infestation was 67.3%. There was significant association between head lice infestation and school grade, family size, parents' literacy, bathing facilities, frequency of hair washing, and use of shared articles (p < 0.05). The effectiveness of 1% permethrin shampoo for head lice treatment was 29.2, 68.9, and 90.3% after the first, second, and third weeks, respectively. The head lice infestation is a health problem in primary school girls of Bashagard County. Improvement of socioeconomic status and providing appropriate educational programs about head lice risk factors and prevention can be effective for reduction of infestation in this area. This trial has been registered and approved by Hormozgan University of Medical Sciences ethical committee (Trial No.764). Trial registration date: March 17 2014.

  19. Size-dependent longitudinal plasmon resonance wavelength and extraordinary scattering properties of Au nanobipyramids.

    PubMed

    Wang, Wenhao; Yu, Peng; Zhong, Zhiqin; Tong, Xin; Liu, Tianji; Li, Yanbo; Ashalley, Eric; Chen, Huanyang; Wu, Jiang; Wang, Zhiming

    2018-08-31

    Au nanobipyramids (NBPs) with sharp tips and narrow plasmon linewidths are ideal candidates for plasmonic applications. In this paper, we investigated the influencing factors of longitudinal plasmon resonance wavelength (LPRW) and scattering properties of single Au NBP by simulation. Compared with the volume, we establish the aspect ratio (length/width) as the dominant factor that affects the LPRW of Au NBPs. Plasmonic nanoparticles have been widely used for light-trapping enhancement in photovoltaics. To give a profound understanding of the superior light harvesting properties of Au NBPs, the near-field localization effect and far-field scattering mechanism of Au NBPs were investigated. Under the light injection at LPRW, the tip area shows near-field enhancement and the maximum scattering intensity appears on the side area of the waist owing to the remarkable optical absorption near the tips. Additionally, we confirm the fraction of light scattered into the substrate and angular distribution of the light scattered by the Au NBPs. The fraction of light scattered into the substrate reaches up to 97% from 400-1100 nm and preserves a broadband spectrum. This suggests that the NBP has a predominant forward scattering and reduced backward scattering. The excellent plasmonic scattering properties of Au NBPs are promising in photovoltaic devices and photothermal therapy.

  20. [Light scattering extinction properties of atmospheric particle and pollution characteristics in hazy weather in Hangzhou].

    PubMed

    Xu, Chang; Ye, Hui; Shen, Jian-Dong; Sun, Hong-Liang; Hong, Sheng-Mao; Jiao, Li; Huang, Kan

    2014-12-01

    In order to evaluate the influence of particle scattering on visibility, light scattering coefficient, particle concentrations and meteorological factor were simultaneously monitored from July 2011 to June 2012 in Hangzhou. Daily scattering coefficients ranged from 108.4 to 1 098.1 Mm(-1), with an annual average concentration of 428.6 Mm(-1) ± 200.2 Mm(-1). Seasonal variation of scattering coefficients was significant, with the highest concentrations observed in autumn and winter and the lowest in summer. It was found there were two peaks for the average diurnal variations of the scattering coefficient, which could be observed at 08:00 and 21:00. The scattering efficiencies of PM2.5 and PM10 were 7.6 m2 x g(-1) and 4.4 m2 x g(-1), respectively. The particle scattering was about 90.2 percent of the total light extinction. The scattering coefficients were 684.4 Mm(-1) ± 218.1 Mm(-1) and 1 095.4 Mm(-1) ± 397.7 Mm(-1) in hazy and heavy hazy days, respectively, which were 2.6 and 4.2 times as high as in non-hazy weather, indicating that particle scattering is the main factor for visibility degradation and the occurrence of hazy weather in Hangzhou.

  1. X-ray Intermolecular Structure Factor (XISF): separation of intra- and intermolecular interactions from total X-ray scattering data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mou, Q.; Benmore, C. J.; Yarger, J. L.

    2015-06-01

    XISF is a MATLAB program developed to separate intermolecular structure factors from total X-ray scattering structure factors for molecular liquids and amorphous solids. The program is built on a trust-region-reflective optimization routine with the r.m.s. deviations of atoms physically constrained. XISF has been optimized for performance and can separate intermolecular structure factors of complex molecules.

  2. X-ray Intermolecular Structure Factor ( XISF ): separation of intra- and intermolecular interactions from total X-ray scattering data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mou, Q.; Benmore, C. J.; Yarger, J. L.

    2015-05-09

    XISFis a MATLAB program developed to separate intermolecular structure factors from total X-ray scattering structure factors for molecular liquids and amorphous solids. The program is built on a trust-region-reflective optimization routine with the r.m.s. deviations of atoms physically constrained.XISFhas been optimized for performance and can separate intermolecular structure factors of complex molecules.

  3. Factors Influencing Helmet Use, Head Injury, and Hospitalization Among Children Involved in Skateboarding and Snowboarding Accidents

    PubMed Central

    Sadeghian, Homa; Nguyen, Brian; Huynh, Nhan; Rouch, Joshua; Lee, Steven L; Bazargan-Hejazi, Shahrzad

    2017-01-01

    Context Up to 75% of skateboarders and snowboarders admitted to the hospital sustain head injuries. It is unclear why not all children and teenagers wear helmets while snowboarding and skateboarding given the protection they afford. Objectives To report on the prevalence of, and factors associated with, skateboarding and snowboarding in injured children and to explore factors that influence helmet use, head injury, and hospitalization in this sample. Design A cross-sectional study of skateboard- and snowboard-associated injuries from 2003 to 2012 among individuals younger than age 18 years using National Electronic Injury Surveillance System (NEISS) data from approximately 100 hospitals. Main Outcome Measures: Helmet use, head injury, and hospitalization. Results Of 1742 patients in the study, 852 (48.9%) and 890 (51.1%) were skateboarders and snowboarders, respectively. Overall, 907 (52.1%) did not use helmets, and 704 (40.4%) sustained head injuries. Multiple logistic regression analysis showed that age, race/ethnicity, location of boarding, and engaging in skateboarding influenced helmet use. Sex, race/ethnicity, helmet use, and skateboarding predicted head injury. Age, sex, skateboarding, and head injury predicted hospital admission. Conclusion Statistically significant differences exist in helmet use, head injury, and hospitalization rates between skateboarders and snowboarders. Our findings suggest that injury prevention and outreach programs are needed to increase helmet use and reduce the risk of head injury and hospitalization in skateboarders and other at-risk groups. Further studies are needed to clarify the association between race/ethnicity and helmet use among skateboarders and snowboarders. PMID:28406787

  4. Influence of multiple scattering on CloudSat measurements in snow: A model study

    NASA Astrophysics Data System (ADS)

    Matrosov, Sergey Y.; Battaglia, Alessandro

    2009-06-01

    The effects of multiple scattering on larger precipitating hydrometers have an influence on measurements of the spaceborne W-band (94 GHz) CloudSat radar. This study presents initial quantitative estimates of these effects in “dry” snow using radiative transfer calculations for appropriate snowfall models. It is shown that these effects become significant (i.e., greater than approximately 1 dB) when snowfall radar reflectivity factors are greater than about 10-15 dBZ. Reflectivity enhancement due to multiple scattering can reach 4-5 dB in heavier stratiform snowfalls. Multiple scattering effects counteract signal attenuation, so the observed CloudSat reflectivity factors in snowfall could be relatively close to the values that would be observed in the case of single scattering and the absence of attenuation.

  5. The gap gene giant of Rhodnius prolixus is maternally expressed and required for proper head and abdomen formation.

    PubMed

    Lavore, Andrés; Pagola, Lucía; Esponda-Behrens, Natalia; Rivera-Pomar, Rolando

    2012-01-01

    The segmentation process in insects depends on a hierarchical cascade of gene activity. The first effectors downstream of the maternal activation are the gap genes, which divide the embryo in broad fields. We discovered a sequence corresponding to the leucine-zipper domain of the orthologue of the gene giant (Rp-gt) in traces from the genome of Rhodnius prolixus, a hemipteran with intermediate germ-band development. We cloned the Rp-gt gene from a normalized cDNA library and characterized its expression and function. Bioinformatic analysis of 12.5 kbp of genomic sequence containing the Rp-gt transcriptional unit shows a cluster of bona fide regulatory binding sites, which is similar in location and structure to the predicted posterior expression domain of the Drosophila orthologue. Rp-gt is expressed in ovaries and maternally supplied in the early embryo. The maternal contribution forms a gradient of scattered patches of mRNA in the preblastoderm embryo. Zygotic Rp-gt is expressed in two domains that after germ band extension are restricted to the head and the posterior growth zone. Parental RNAi shows that Rp-gt is required for proper head and abdomen formation. The head lacks mandibulary and maxillary appendages and shows reduced clypeus-labrum, while the abdomen lacks anterior segments. We conclude that Rp-gt is a gap gene on the head and abdomen and, in addition, has a function in patterning the anterior head capsule suggesting that the function of gt in hemipterans is more similar to dipterans than expected. Copyright © 2011. Published by Elsevier Inc.

  6. Fully relativistic form factor for Thomson scattering.

    PubMed

    Palastro, J P; Ross, J S; Pollock, B; Divol, L; Froula, D H; Glenzer, S H

    2010-03-01

    We derive a fully relativistic form factor for Thomson scattering in unmagnetized plasmas valid to all orders in the normalized electron velocity, beta[over ]=v[over ]/c. The form factor is compared to a previously derived expression where the lowest order electron velocity, beta[over], corrections are included [J. Sheffield, (Academic Press, New York, 1975)]. The beta[over ] expansion approach is sufficient for electrostatic waves with small phase velocities such as ion-acoustic waves, but for electron-plasma waves the phase velocities can be near luminal. At high phase velocities, the electron motion acquires relativistic corrections including effective electron mass, relative motion of the electrons and electromagnetic wave, and polarization rotation. These relativistic corrections alter the scattered emission of thermal plasma waves, which manifest as changes in both the peak power and width of the observed Thomson-scattered spectra.

  7. Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization

    NASA Astrophysics Data System (ADS)

    Xu, J.; Sisniega, A.; Zbijewski, W.; Dang, H.; Stayman, J. W.; Wang, X.; Foos, D. H.; Aygun, N.; Koliatsos, V. E.; Siewerdsen, J. H.

    2016-04-01

    Detection of acute intracranial hemorrhage (ICH) is important for diagnosis and treatment of traumatic brain injury, stroke, postoperative bleeding, and other head and neck injuries. This paper details the design and development of a cone-beam CT (CBCT) system developed specifically for the detection of low-contrast ICH in a form suitable for application at the point of care. Recognizing such a low-contrast imaging task to be a major challenge in CBCT, the system design began with a rigorous analysis of task-based detectability including critical aspects of system geometry, hardware configuration, and artifact correction. The imaging performance model described the three-dimensional (3D) noise-equivalent quanta using a cascaded systems model that included the effects of scatter, scatter correction, hardware considerations of complementary metal-oxide semiconductor (CMOS) and flat-panel detectors (FPDs), and digitization bit depth. The performance was analyzed with respect to a low-contrast (40-80 HU), medium-frequency task representing acute ICH detection. The task-based detectability index was computed using a non-prewhitening observer model. The optimization was performed with respect to four major design considerations: (1) system geometry (including source-to-detector distance (SDD) and source-to-axis distance (SAD)); (2) factors related to the x-ray source (including focal spot size, kVp, dose, and tube power); (3) scatter correction and selection of an antiscatter grid; and (4) x-ray detector configuration (including pixel size, additive electronics noise, field of view (FOV), and frame rate, including both CMOS and a-Si:H FPDs). Optimal design choices were also considered with respect to practical constraints and available hardware components. The model was verified in comparison to measurements on a CBCT imaging bench as a function of the numerous design parameters mentioned above. An extended geometry (SAD  =  750 mm, SDD  =  1100 mm) was found to be advantageous in terms of patient dose (20 mGy) and scatter reduction, while a more isocentric configuration (SAD  =  550 mm, SDD  =  1000 mm) was found to give a more compact and mechanically favorable configuration with minor tradeoff in detectability. An x-ray source with a 0.6 mm focal spot size provided the best compromise between spatial resolution requirements and x-ray tube power. Use of a modest anti-scatter grid (8:1 GR) at a 20 mGy dose provided slight improvement (~5-10%) in the detectability index, but the benefit was lost at reduced dose. The potential advantages of CMOS detectors over FPDs were quantified, showing that both detectors provided sufficient spatial resolution for ICH detection, while the former provided a potentially superior low-dose performance, and the latter provided the requisite FOV for volumetric imaging in a centered-detector geometry. Task-based imaging performance modeling provides an important starting point for CBCT system design, especially for the challenging task of ICH detection, which is somewhat beyond the capabilities of existing CBCT platforms. The model identifies important tradeoffs in system geometry and hardware configuration, and it supports the development of a dedicated CBCT system for point-of-care application. A prototype suitable for clinical studies is in development based on this analysis.

  8. XAFS Debye-Waller Factors Temperature-Dependent Expressions for Fe+2-Porphyrin Complexes

    NASA Astrophysics Data System (ADS)

    Dimakis, Nicholas; Bunker, Grant

    2007-02-01

    We present an efficient and accurate method for directly calculating single and multiple scattering X-ray absorption fine structure (XAFS) thermal Debye-Waller factors for Fe+2 -porphiryn complexes. The number of multiple scattering Debye-Waller factors on metal porphyrin centers exceeds the number of available parameters that XAFS experimental data can support during fitting with simulated spectra. Using the Density Functional Theory (DFT) under the hybrid functional of X3LYP, phonon normal mode spectrum properties are used to express the mean square variation of the half-scattering path length for a Fe+2 -porphiryn complex as a function of temperature for the most important single and multiple scattering paths of the complex thus virtually eliminating them from the fitting procedure. Modeled calculations are compared with corresponding values obtained from DFT-built and optimized Fe+2 -porphyrin bis-histidine structure as well as from experimental XAFS spectra previously reported. An excellent agreement between calculated and reference Debye-Waller factors for Fe+2-porphyrins is obtained.

  9. WE-F-16A-03: 3D Printer Application in Proton Therapy: A Novel Method to Deliver Passive-Scattering Proton Beams with a Fixed Range and Modulation for SRS and SRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, X; Witztum, A; Liang, X

    2014-06-15

    Purpose: To present a novel technique to deliver passive-scattering proton beam with fixed range and modulation using a 3D printed patient-specific bolus for proton stereotactic radiosurgery and radiotherapy. Methods: A CIRS head phantom was used to simulate a patient with a small brain lesion. A custom bolus was created in the Eclipse Treatment Planning System (TPS) to compensate for the different water equivalent depths from the patient surface to the target from multiple beam directions. To simulate arc therapy, a plan was created on the initial CT using three passive-scattering proton beams with a fixed range and modulations irradiating frommore » different angles. The DICOM-RT structure file of the bolus was exported from the TPS and converted to STL format for 3D printing. The phantom was rescanned with the printed custom bolus and head cup to verify the dose distribution comparing to the initial plan. EBT3 films were placed in the sagital plane of the target to verify the delivered dose distribution. The relative stopping power of the printing material(ABSplus-P430) was measured using the Zebra multi-plate ion chamber. Results: The relative stopping power of the 3D printing material, ABSplus-P430 was 1.05 which is almost water equivalent. The dose difference between verification CT and Initial CT is almost negligible. Film measurement also confirmed the accuracy for this new proton delivery technique. Conclusion: Our method using 3D printed range modifiers simplify the treatment delivery of multiple passive-scattering beams in treatment of small lesion in brain. This technique makes delivery of multiple beam more efficient and can be extended to allow arc therapy with proton beams. The ability to create and construct complex patient specific bolus structures provides a new dimension in creating optimized quality treatment plans not only for proton therapy but also for electron and photon therapy.« less

  10. Materials Design via Optimized Intramolecular Noncovalent Interactions for High-Performance Organic Semiconductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Xiaojie; Liao, Qiaogan; Manley, Eric F.

    2016-03-15

    We report the design, synthesis, and implemention in semiconducting polymers of a novel head-to-head linkage containing the TRTOR (3-alkyl-3'-alkoxy-2,2'-bithiophene) donor subunit having a single strategically optimized, planarizing noncovalent S···O interaction. Diverse complementary thermal, optical, electrochemical, X-ray scattering, electrical, photovoltaic, and electron microscopic characterization techniques are applied to establish structure–property correlations in a TRTOR-based polymer series. In comparison to monomers having double S···O interactions, replacing one alkoxy substituent with a less electron-donating alkyl one yields TRTOR-based polymers with significantly depressed (0.2–0.3 eV) HOMOs. Furthermore, the weaker single S···O interaction and greater TRTOR steric encumberance enhances materials processability without sacrificing backbone planarity.more » From another perspective, TRTOR has comparable electronic properties to ring-fused 5H-dithieno[3,2-b:2',3'-d]pyran (DTP) subunits, but a centrosymmetric geometry which promotes a more compact and ordered structure than bulkier, axisymmetric DTP. Compared to monosubstituted TTOR (3-alkoxy-2,2'-bithiophene), alkylation at the TRTOR bithiophene 3-position enhances conjugation and polymer crystallinity with contracted π–π stacking. Grazing incidence wide-angle X-ray scattering (GIWAXS) data reveal that the greater steric hindrance and the weaker single S···O interaction are not detrimental to close packing and high crystallinity. As a proof of materials design, copolymerizing TRTOR with phthalimides yields copolymers with promising thin-film transistor mobility as high as 0.42 cm2/(V·s) and 6.3% power conversion efficiency in polymer solar cells, the highest of any phthalimide copolymers reported to date. The depressed TRTOR HOMOs imbue these polymers with substantially increased Ion/Ioff ratios and Voc’s versus analogous subunits with multiple electron donating, planarizing alkoxy substituents. Implementing a head-to-head linkage with an alkyl/alkoxy substitution pattern and a single S···O interaction is a promising strategy for organic electronics materials design.« less

  11. Morphometric findings in avascular necrosis of the femoral head.

    PubMed

    Kamal, Diana; Trăistaru, Rodica; Alexandru, D O; Kamal, C K; Pirici, D; Pop, O T; Mălăescu, D Gh

    2012-01-01

    Avascular necrosis of the femoral head is an illness with a controversial etiology, the trigger event being the suppression of blood flow to the femoral head. The disease affects mostly young adults within their third and fifth decade, the majority of the patients being men. The main risk factors are trauma, chronic alcohol consumption, smoking, corticotherapy. The main goal of our study is to describe the morphometric changes found in the bone tissue of patients diagnosed with avascular necrosis of the femoral head, with different risk factors, by comparing the area of bone trabeculae inside the area of necrosis with that from the adjacent viable tissue. The morphometric study used biological material from 16 patients with ages between 29 and 57 years, who underwent surgery for avascular necrosis of the femoral head. They were admitted in the Orthopedics Department at the Emergency County Hospital in Craiova between 2010 and 2011 and were split into four groups. Group I presented trauma as the main risk factor, Group II had corticotherapy as the defining risk factor, Group III presented chronic alcohol consumption and Group IV was represented by the patients who smoked and exhibited chronic alcohol consumption. There was not a significant statistical difference between the areas of bone trabeculae of the four groups when we compared viable bone tissue to the necrotized one. Knowing the risk factors of the avascular necrosis of the femoral head is critical to the management of the disease, because diagnosing it in an early stage is a necessity for obtaining a good result for conservative treatment.

  12. Journal Club: Head CT scans in the emergency department for syncope and dizziness.

    PubMed

    Mitsunaga, Myles M; Yoon, Hyo-Chun

    2015-01-01

    The purpose of this study was to determine the yield of acutely abnormal findings on head CT scans in patients presenting to the emergency department with dizziness, near-syncope, or syncope and to determine the clinical factors that potentially predicted acutely abnormal head CT findings and hospital admission. We retrospectively reviewed the electronic medical records of all patients presenting to an HMO emergency department between July 1, 2012, and December 31, 2012, who underwent head CT for a primary complaint of dizziness, syncope, or near-syncope. The primary outcomes were head CT scans with acutely abnormal findings and hospital admission. Binary logistic regression was used to assess the association between clinical variables and acute head CT findings and between clinical variables and hospital admission. Of the 253 patients who presented with dizziness, 7.1% had head CT scans with acutely abnormal findings, and 18.6% were admitted. Of the 236 patients who presented with syncope or near-syncope, 6.4% had head CT scans with acutely abnormal findings, and 39.8% were admitted. The following three clinical factors were found to be significantly correlated with acutely abnormal head CT findings: a focal neurologic deficit (p = 0.003), age greater than 60 years (p = 0.011), and acute head trauma (p = 0.026). Our results suggest that most patients presenting with syncope or dizziness to the emergency department may not benefit from head CT unless they are older, have a focal neurologic deficit, or have a history of recent head trauma.

  13. Quantum theory for the dynamic structure factor in correlated two-component systems in nonequilibrium: Application to x-ray scattering.

    PubMed

    Vorberger, J; Chapman, D A

    2018-01-01

    We present a quantum theory for the dynamic structure factors in nonequilibrium, correlated, two-component systems such as plasmas or warm dense matter. The polarization function, which is needed as the input for the calculation of the structure factors, is calculated in nonequilibrium based on a perturbation expansion in the interaction strength. To make our theory applicable for x-ray scattering, a generalized Chihara decomposition for the total electron structure factor in nonequilibrium is derived. Examples are given and the influence of correlations and exchange on the structure and the x-ray-scattering spectrum are discussed for a model nonequilibrium distribution, as often encountered during laser heating of materials, as well as for two-temperature systems.

  14. Quantum theory for the dynamic structure factor in correlated two-component systems in nonequilibrium: Application to x-ray scattering

    NASA Astrophysics Data System (ADS)

    Vorberger, J.; Chapman, D. A.

    2018-01-01

    We present a quantum theory for the dynamic structure factors in nonequilibrium, correlated, two-component systems such as plasmas or warm dense matter. The polarization function, which is needed as the input for the calculation of the structure factors, is calculated in nonequilibrium based on a perturbation expansion in the interaction strength. To make our theory applicable for x-ray scattering, a generalized Chihara decomposition for the total electron structure factor in nonequilibrium is derived. Examples are given and the influence of correlations and exchange on the structure and the x-ray-scattering spectrum are discussed for a model nonequilibrium distribution, as often encountered during laser heating of materials, as well as for two-temperature systems.

  15. Factors Involved in Iranian Women Heads of Household’s Health Promotion Activities: A Grounded Theory Study

    PubMed Central

    Rafii, Forough; Seyedfatemi, Naima; Rezaei, Mahboubeh

    2013-01-01

    We aimed to explore and describe the factors involved in Iranian women heads of household’s health promotion activities. Grounded theory was used as the method. Sixteen women heads of household were recruited. Data were generated by semi structured interviews. Our findings indicated that remainder of resources (money, time and energy) alongside perceived severity of health risk were two main factors whereas women’s personal and socio-economic characteristics were two contextual factors involved in these women's health promotion activities. To help these women improve their health status, we recommended that the government, non-governmental organizations and health care professionals provide them with required resources and increase their knowledge by holding training sessions. PMID:24039645

  16. Quantitative proton imaging from multiple physics processes: a proof of concept

    NASA Astrophysics Data System (ADS)

    Bopp, C.; Rescigno, R.; Rousseau, M.; Brasse, D.

    2015-07-01

    Proton imaging is developed in order to improve the accuracy of charged particle therapy treatment planning. It makes it possible to directly map the relative stopping powers of the materials using the information on the energy loss of the protons. In order to reach a satisfactory spatial resolution in the reconstructed images, the position and direction of each particle is recorded upstream and downstream from the patient. As a consequence of individual proton detection, information on the transmission rate and scattering of the protons is available. Image reconstruction processes are proposed to make use of this information. A proton tomographic acquisition of an anthropomorphic head phantom was simulated. The transmission rate of the particles was used to reconstruct a map of the macroscopic cross section for nuclear interactions of the materials. A two-step iterative reconstruction process was implemented to reconstruct a map of the inverse scattering length of the materials using the scattering of the protons. Results indicate that, while the reconstruction processes should be optimized, it is possible to extract quantitative information from the transmission rate and scattering of the protons. This suggests that proton imaging could provide additional knowledge on the materials that may be of use to further improve treatment planning.

  17. Quantitative proton imaging from multiple physics processes: a proof of concept.

    PubMed

    Bopp, C; Rescigno, R; Rousseau, M; Brasse, D

    2015-07-07

    Proton imaging is developed in order to improve the accuracy of charged particle therapy treatment planning. It makes it possible to directly map the relative stopping powers of the materials using the information on the energy loss of the protons. In order to reach a satisfactory spatial resolution in the reconstructed images, the position and direction of each particle is recorded upstream and downstream from the patient. As a consequence of individual proton detection, information on the transmission rate and scattering of the protons is available. Image reconstruction processes are proposed to make use of this information. A proton tomographic acquisition of an anthropomorphic head phantom was simulated. The transmission rate of the particles was used to reconstruct a map of the macroscopic cross section for nuclear interactions of the materials. A two-step iterative reconstruction process was implemented to reconstruct a map of the inverse scattering length of the materials using the scattering of the protons. Results indicate that, while the reconstruction processes should be optimized, it is possible to extract quantitative information from the transmission rate and scattering of the protons. This suggests that proton imaging could provide additional knowledge on the materials that may be of use to further improve treatment planning.

  18. Risk factors for obstetric anal sphincter injuries and postpartum anal and urinary incontinence: a case-control trial.

    PubMed

    Burrell, Madeline; Dilgir, Sapna; Patton, Vicki; Parkin, Katrina; Karantanis, Emmanuel

    2015-03-01

    Obstetric anal sphincter injuries (OASIS) cause serious maternal morbidity for mothers. A clearer understanding of aetiological factors is needed. We aimed to determine the risk factors for OASIS . Birth details of 222 primiparous women sustaining OASIS were compared with 174 women who did not sustain OASIS (controls) to determine the relevant risk factors. The data underwent univariate analysis and logistic regression analysis. Asian or Indian ethnicity, operative vaginal birth (p = 0.00), persistent occipito-posterior position (p = 0.038) and rapid uncontrolled delivery of the head were identified as risk factors for OASIS. Pushing time, use of epidural, episiotomy and head circumference were not predictors of OASIS. Women with Asian or Indian ethnicity, operative vaginal birth, persistent occipito-posterior position and rapid uncontrolled delivery of the fetal head were likely to sustain OASIS. Awareness of these factors may help to minimise the incidence of OASIS.

  19. Proximate content of wild and cultured eel (Anguilla bicolor) in different part of body

    NASA Astrophysics Data System (ADS)

    Wijayanti, I.; Susilo, E. S.

    2018-02-01

    Proximate content in fish varies depends on intrinsic and extrinsic factors. Intrinsic factors include species, sexual maturity, size and body parts. Extrinsic factors include habitat, season and type of food (diet). This study aimed to know the effect of fish body parts (intrinsic factor) on proximate levels in wild and cultured eel (extrinsic). The experimental design used factorial completely randomized design with two factors 2x3. The first factor is the habitat of eel (wild and cultured) and the second factor is the part of the body (head, body and tail) with five replications. The result of statistical analysis showed that there was interaction between fish habitat and body part on moisture, protein, ash and carbohydrate content (P <0.05), but no interaction on fat content and energy (P> 0.05). The highest water content (67.02%) was found in head of wild and the lowest one (59.44%) in the tail of wild eel; The highest protein content (18.09%) was found in the body of cultured eel and the lowest one (15.72%) was in the body of wild eel; The highest ash content (3.73%) was the head of wild eel and the lowest (1.32%) was in the body of cultured eel; The highest carbohydrate (3.73%) was found in the head of cultured eel and the lowest one (0.16%) was in the body of cultured. The wild eel had higher fat content and energy than cultured one, while the fat content and energy in body and tail were higher than in head.

  20. Meteoroid Fragmentation as Revealed in Head- and Trail-Echoes Observed with the Arecibo UHF and VHF Radars

    NASA Technical Reports Server (NTRS)

    Mathews, J. D.; Malhorta, A.

    2011-01-01

    We report recent 46.8/430 MHz (VHF/UHF) radar meteor observations at Arecibo Observatory (AO) that reveal many previously unreported features in the radar meteor return - including flare-trails at both UHF and VHF - that are consistent with meteoroid fragmentation. Signature features of fragmentation include strong intra-pulse and pulse-to-pulse fading as the result of interference between or among multiple meteor head-echo returns and between head-echo and impulsive flare or "point" trail-echoes. That strong interference fading occurs implies that these scatterers exhibit well defined phase centers and are thus small compared with the wavelength. These results are consistent with and offer advances beyond a long history of optical and radar meteoroid fragmentation studies. Further, at AO, fragmenting and flare events are found to be a large fraction of the total events even though these meteoroids are likely the smallest observed by the major radars. Fragmentation is found to be a major though not dominate component of the meteors observed at other HPLA radars that are sensitive to larger meteoroids.

  1. Spontaneous melanotic lesions in axillary seabream, Pagellus acarne (Risso).

    PubMed

    Ramos, P; Victor, P; Branco, S

    2013-09-01

    In this article, we describe spontaneous melanotic lesions in the skin of axillary seabream, Pagellus acarne (Risso), from a defined area of the Portuguese Coast, located in Cabo da Roca and Foz do Arelho. The lesions corresponded to the black pigmentation spots on the skin of the head, fins, lips and conjunctiva and, additionally, black nodules on the skin of the head and lips. In some specimens, the nodular formations in the head changed their anatomical conformation. Histologically, there were melanophores scattered along the basement membrane or forming aggregates in the dermis, infiltrating the subcutaneous tissue but not invading the adjacent muscle tissue. The aim of this study was to characterize the macroscopic and microscopic features of the pigmented lesions. These fish show sessile hyperpigmented lesions (spots) that correspond to proliferative lesions of melanophores in the dermis and nodular lesions that correspond to neoplastic lesions, melanophoromas. The melanophores in such lesions showed high concentration of melanin in the cytoplasm, moderate pleomorphism and compact distribution throughout all of the dermis. © 2013 John Wiley & Sons Ltd.

  2. WE-AB-207A-08: BEST IN PHYSICS (IMAGING): Advanced Scatter Correction and Iterative Reconstruction for Improved Cone-Beam CT Imaging On the TrueBeam Radiotherapy Machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, A; Paysan, P; Brehm, M

    2016-06-15

    Purpose: To improve CBCT image quality for image-guided radiotherapy by applying advanced reconstruction algorithms to overcome scatter, noise, and artifact limitations Methods: CBCT is used extensively for patient setup in radiotherapy. However, image quality generally falls short of diagnostic CT, limiting soft-tissue based positioning and potential applications such as adaptive radiotherapy. The conventional TrueBeam CBCT reconstructor uses a basic scatter correction and FDK reconstruction, resulting in residual scatter artifacts, suboptimal image noise characteristics, and other artifacts like cone-beam artifacts. We have developed an advanced scatter correction that uses a finite-element solver (AcurosCTS) to model the behavior of photons as theymore » pass (and scatter) through the object. Furthermore, iterative reconstruction is applied to the scatter-corrected projections, enforcing data consistency with statistical weighting and applying an edge-preserving image regularizer to reduce image noise. The combined algorithms have been implemented on a GPU. CBCT projections from clinically operating TrueBeam systems have been used to compare image quality between the conventional and improved reconstruction methods. Planning CT images of the same patients have also been compared. Results: The advanced scatter correction removes shading and inhomogeneity artifacts, reducing the scatter artifact from 99.5 HU to 13.7 HU in a typical pelvis case. Iterative reconstruction provides further benefit by reducing image noise and eliminating streak artifacts, thereby improving soft-tissue visualization. In a clinical head and pelvis CBCT, the noise was reduced by 43% and 48%, respectively, with no change in spatial resolution (assessed visually). Additional benefits include reduction of cone-beam artifacts and reduction of metal artifacts due to intrinsic downweighting of corrupted rays. Conclusion: The combination of an advanced scatter correction with iterative reconstruction substantially improves CBCT image quality. It is anticipated that clinically acceptable reconstruction times will result from a multi-GPU implementation (the algorithms are under active development and not yet commercially available). All authors are employees of and (may) own stock of Varian Medical Systems.« less

  3. Universal analytical scattering form factor for shell-, core-shell, or homogeneous particles with continuously variable density profile shape.

    PubMed

    Foster, Tobias

    2011-09-01

    A novel analytical and continuous density distribution function with a widely variable shape is reported and used to derive an analytical scattering form factor that allows us to universally describe the scattering from particles with the radial density profile of homogeneous spheres, shells, or core-shell particles. Composed by the sum of two Fermi-Dirac distribution functions, the shape of the density profile can be altered continuously from step-like via Gaussian-like or parabolic to asymptotically hyperbolic by varying a single "shape parameter", d. Using this density profile, the scattering form factor can be calculated numerically. An analytical form factor can be derived using an approximate expression for the original Fermi-Dirac distribution function. This approximation is accurate for sufficiently small rescaled shape parameters, d/R (R being the particle radius), up to values of d/R ≈ 0.1, and thus captures step-like, Gaussian-like, and parabolic as well as asymptotically hyperbolic profile shapes. It is expected that this form factor is particularly useful in a model-dependent analysis of small-angle scattering data since the applied continuous and analytical function for the particle density profile can be compared directly with the density profile extracted from the data by model-free approaches like the generalized inverse Fourier transform method. © 2011 American Chemical Society

  4. The INHANCE consortium: toward a better understanding of the causes and mechanisms of head and neck cancer.

    PubMed

    Winn, D M; Lee, Y-C A; Hashibe, M; Boffetta, P

    2015-09-01

    The International Head and Neck Cancer Epidemiology (INHANCE) consortium is a collaboration of research groups leading large epidemiology studies to improve the understanding of the causes and mechanisms of head and neck cancer. The consortium includes investigators of 35 studies who have pooled their data on 25 500 patients with head and neck cancer (i.e., cancers of the oral cavity, oropharynx, hypopharynx, and larynx) and 37 100 controls. The INHANCE analyses have confirmed that tobacco use and alcohol intake are key risk factors of these diseases and have provided precise estimates of risk and dose response, the benefit of quitting, and the hazard of smoking even a few cigarettes per day. Other risk factors include short height, lean body mass, low education and income, and a family history of head and neck cancer. Risk factors are generally similar for oral cavity, pharynx, and larynx, although the magnitude of risk may vary. Some major strengths of pooling data across studies include more precise estimates of risk and the ability to control for potentially confounding factors and to examine factors that may interact with each other. The INHANCE consortium provides evidence of the scientific productivity and discoveries that can be obtained from data pooling projects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Rayleigh, Compton and K-shell radiative resonant Raman scattering in 83Bi for 88.034 keV γ-rays

    NASA Astrophysics Data System (ADS)

    Kumar, Sanjeev; Sharma, Veena; Mehta, D.; Singh, Nirmal

    2007-11-01

    The Rayleigh, Compton and K-shell radiative resonant Raman scattering cross-sections for the 88.034 keV γ-rays have been measured in the 83Bi (K-shell binding energy = 90.526 keV) element. The measurements have been performed at 130° scattering angle using reflection-mode geometrical arrangement involving the 109Cd radioisotope as photon source and an LEGe detector. Computer simulations were exercised to determine distributions of the incident and emission angles, which were further used in evaluation of the absorption corrections for the incident and emitted photons in the target. The measured cross-sections for the Rayleigh scattering are compared with the modified form-factors (MFs) corrected for the anomalous-scattering factors (ASFs) and the S-matrix calculations; and those for the Compton scattering are compared with the Klein-Nishina cross-sections corrected for the non-relativistic Hartree-Fock incoherent scattering function S(x, Z). The ratios of the measured KL2, KL3, KM and KN2,3 radiative resonant Raman scattering cross-sections are found to be in general agreement with those of the corresponding measured fluorescence transition probabilities.

  6. Head flexion angle while using a smartphone.

    PubMed

    Lee, Sojeong; Kang, Hwayeong; Shin, Gwanseob

    2015-01-01

    Repetitive or prolonged head flexion posture while using a smartphone is known as one of risk factors for pain symptoms in the neck. To quantitatively assess the amount and range of head flexion of smartphone users, head forward flexion angle was measured from 18 participants when they were conducing three common smartphone tasks (text messaging, web browsing, video watching) while sitting and standing in a laboratory setting. It was found that participants maintained head flexion of 33-45° (50th percentile angle) from vertical when using the smartphone. The head flexion angle was significantly larger (p < 0.05) for text messaging than for the other tasks, and significantly larger while sitting than while standing. Study results suggest that text messaging, which is one of the most frequently used app categories of smartphone, could be a main contributing factor to the occurrence of neck pain of heavy smartphone users. Practitioner Summary: In this laboratory study, the severity of head flexion of smartphone users was quantitatively evaluated when conducting text messaging, web browsing and video watching while sitting and standing. Study results indicate that text messaging while sitting caused the largest head flexion than that of other task conditions.

  7. Principle Study of Head Meridian Acupoint Massage to Stress Release via Grey Data Model Analysis.

    PubMed

    Lee, Ya-Ting

    2016-01-01

    This paper presents the scientific study of the effectiveness and action principle of head meridian acupoint massage by applying the grey data model analysis approach. First, the head massage procedure for massaging the important head meridian acupuncture points including Taiyang, Fengfu, Tianzhu, Fengqi, and Jianjing is formulated in a standard manner. Second, the status of the autonomic nervous system of each subject is evaluated by using the heart rate variability analyzer before and after the head massage following four weeks. Afterward, the physiological factors of autonomic nerves are quantitatively analyzed by using the grey data modeling theory. The grey data analysis can point out that the status of autonomic nervous system is greatly improved after the massage. The order change of the grey relationship weighting of physiological factors shows the action principle of the sympathetic and parasympathetic nerves when performing head massage. In other words, the grey data model is able to distinguish the detailed interaction of the autonomic nervous system and the head meridian acupoint massage. Thus, the stress relaxing effect of massaging head meridian acupoints is proved, which is lacked in literature. The results can be a reference principle for massage health care in practice.

  8. Principle Study of Head Meridian Acupoint Massage to Stress Release via Grey Data Model Analysis

    PubMed Central

    Lee, Ya-Ting

    2016-01-01

    This paper presents the scientific study of the effectiveness and action principle of head meridian acupoint massage by applying the grey data model analysis approach. First, the head massage procedure for massaging the important head meridian acupuncture points including Taiyang, Fengfu, Tianzhu, Fengqi, and Jianjing is formulated in a standard manner. Second, the status of the autonomic nervous system of each subject is evaluated by using the heart rate variability analyzer before and after the head massage following four weeks. Afterward, the physiological factors of autonomic nerves are quantitatively analyzed by using the grey data modeling theory. The grey data analysis can point out that the status of autonomic nervous system is greatly improved after the massage. The order change of the grey relationship weighting of physiological factors shows the action principle of the sympathetic and parasympathetic nerves when performing head massage. In other words, the grey data model is able to distinguish the detailed interaction of the autonomic nervous system and the head meridian acupoint massage. Thus, the stress relaxing effect of massaging head meridian acupoints is proved, which is lacked in literature. The results can be a reference principle for massage health care in practice. PMID:26904144

  9. Parent or Caregiver, Staff, and Dentist Perspectives on Access to Dental Care Issues for Head Start Children in Ohio

    PubMed Central

    Siegal, Mark D.; Marx, Mary L.; Cole, Shannon L.

    2005-01-01

    Objectives. We conducted 5 surveys on consumer and provider perspectives on access to dental care for Ohio Head Start children to assess the need and appropriate strategies for action. Methods. We collected information from Head Start children (open-mouth screenings), their parents or caregivers (questionnaire and telephone interviews), Head Start staff (interviews), and dentists (questionnaire). Geocoded addresses were also analyzed. Results. Twenty-eight percent of Head Start children had at least 1 decayed tooth. For the 11% of parents whose children could not get desired dental care, cost of care or lack of insurance (34%) and dental office factors (20%) were primary factors. Only 7% of general dentists and 29% of pediatric dentists reported accepting children aged 0 through 5 years of age as Medicaid recipients without limitation. Head Start staff and dentists felt that poor appointment attendance negatively affected children’s receiving care, but parents/caregivers said finding accessible dentists was the major problem. Conclusions. Many Ohio Head Start children do not receive dental care. Medicaid and patient age were primary dental office limitations that are partly offset by the role Head Start plays in ensuring dental care. Dentists, Head Start staff, and parents/caregivers have different perspectives on the problem of access to dental care. PMID:16006416

  10. Frequency mismatch in stimulated scattering processes: An important factor for the transverse distribution of scattered light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Tao; Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang, Sichuan 621900; Zheng, Jian, E-mail: jzheng@ustc.edu.cn

    2016-06-15

    A 2D cylindrically symmetric model with inclusion of both diffraction and self-focus effects is developed to deal with the stimulated scattering processes of a single hotspot. The calculated results show that the transverse distribution of the scattered light is sensitive to the longitudinal profiles of the plasma parameters. The analysis of the evolution of the scattered light indicates that it is the frequency mismatch of coupling due to the inhomogeneity of plasmas that determines the transverse distribution of the scattered light.

  11. ’Head-On’ Scattering of a Tubular Cylinder of Finite Length for Radar Target Identification Purposes

    DTIC Science & Technology

    1985-03-01

    environment. The anechoic chamber is enclosed with aluminium plates and internally lined with a radio frequency absorbing material. The absorbing material...provides the necessary attenuation to the reflections from the walls, floor and ceiling, and the aluminium surface provides protection against external...inch aluminium sphere is used. Some measurements are taken with a cylinder with fins attached .The description of the cylinder with fins is shown in

  12. Oncogenic impact of human papilloma virus in head and neck cancer.

    PubMed

    Heffernan, C B; O'Neill, J P; Timon, C

    2010-09-01

    There is considerable debate within the literature about the significance of human papilloma virus in head and neck squamous cell carcinoma, and its potential influence on the prevention, diagnosis, grading, treatment and prognosis of these cancers. Cigarette smoking and alcohol consumption have traditionally been cited as the main risk factors for head and neck cancers. However, human papilloma virus, normally associated with cervical and other genital carcinomas, has emerged as a possible key aetiological factor in head and neck squamous cell carcinoma, especially oropharyngeal cancers. These cancers pose a significant financial burden on health resources and are increasing in incidence. The recent introduction of vaccines targeted against human papilloma virus types 16 and 18, to prevent cervical cancer, has highlighted the need for ongoing research into the importance of human papilloma virus in head and neck squamous cell carcinoma.

  13. Human papilloma virus: a new risk factor in a subset of head and neck cancers.

    PubMed

    Bisht, Manisha; Bist, Sampan Singh

    2011-01-01

    Head and neck cancer is the sixth most common malignancy worldwide. Tobacco smoking and alcohol consumption are two well known behavioral risk factors associated with head and neck cancer. Recently, evidence is mounting that infection with human papilloma virus, most commonly human papilloma virus-16 is responsible for a subset of head and neck squamous cell carcinoma especially tumors of tonsillar origin. The molecular pathway used by human papilloma virus to trigger malignant transformation of tissue is different from that of other well known risk factors, i.e. smoking and alcohol, associated with squamous cell carcinoma. Apparently, these subsets of patients with human papilloma virus positive tumor are more likely to have a better prognosis than human papilloma virus negative tumor. Considering this fact, the human papilloma virus infection should be determined in all oropharyngeal cancers since it can have a major impact on the decision making process of the treatment.

  14. Sensitivity of head and cervical spine injury measures to impact factors relevant to rollover crashes.

    PubMed

    Mattos, G A; Mcintosh, A S; Grzebieta, R H; Yoganandan, N; Pintar, F A

    2015-01-01

    Serious head and cervical spine injuries have been shown to occur mostly independent of one another in pure rollover crashes. In an attempt to define a dynamic rollover crash test protocol that can replicate serious injuries to the head and cervical spine, it is important to understand the conditions that are likely to produce serious injuries to these 2 body regions. The objective of this research is to analyze the effect that impact factors relevant to a rollover crash have on the injury metrics of the head and cervical spine, with a specific interest in the differentiation between independent injuries and those that are predicted to occur concomitantly. A series of head impacts was simulated using a detailed finite element model of the human body, the Total HUman Model for Safety (THUMS), in which the impactor velocity, displacement, and direction were varied. The performance of the model was assessed against available experimental tests performed under comparable conditions. Indirect, kinematic-based, and direct, tissue-level, injury metrics were used to assess the likelihood of serious injuries to the head and cervical spine. The performance of the THUMS head and spine in reconstructed experimental impacts compared well to reported values. All impact factors were significantly associated with injury measures for both the head and cervical spine. Increases in impact velocity and displacement resulted in increases in nearly all injury measures, whereas impactor orientation had opposite effects on brain and cervical spine injury metrics. The greatest cervical spine injury measures were recorded in an impact with a 15° anterior orientation. The greatest brain injury measures occurred when the impactor was at its maximum (45°) angle. The overall kinetic and kinematic response of the THUMS head and cervical spine in reconstructed experiment conditions compare well with reported values, although the occurrence of fractures was overpredicted. The trends in predicted head and cervical spine injury measures were analyzed for 90 simulated impact conditions. Impactor orientation was the only factor that could potentially explain the isolated nature of serious head and spine injuries under rollover crash conditions. The opposing trends of injury measures for the brain and cervical spine indicate that it is unlikely to reproduce the injuries simultaneously in a dynamic rollover test.

  15. Effect of static scatterers in laser speckle contrast imaging: an experimental study on correlation and contrast.

    PubMed

    Vaz, Pedro G; Humeau-Heurtier, Anne; Figueiras, Edite; Correia, Carlos; Cardoso, João

    2017-12-29

    Laser speckle contrast imaging (LSCI) is a non-invasive microvascular blood flow assessment technique with good temporal and spatial resolution. Most LSCI systems, including commercial devices, can perform only qualitative blood flow evaluation, which is a major limitation of this technique. There are several factors that prevent the utilization of LSCI as a quantitative technique. Among these factors, we can highlight the effect of static scatterers. The goal of this work was to study the influence of differences in static and dynamic scatterer concentration on laser speckle correlation and contrast. In order to achieve this, a laser speckle prototype was developed and tested using an optical phantom with various concentrations of static and dynamic scatterers. It was found that the laser speckle correlation could be used to estimate the relative concentration of static/dynamic scatterers within a sample. Moreover, the speckle correlation proved to be independent of the dynamic scatterer velocity, which is a fundamental characteristic to be used in contrast correction.

  16. Effect of static scatterers in laser speckle contrast imaging: an experimental study on correlation and contrast

    NASA Astrophysics Data System (ADS)

    Vaz, Pedro G.; Humeau-Heurtier, Anne; Figueiras, Edite; Correia, Carlos; Cardoso, João

    2018-01-01

    Laser speckle contrast imaging (LSCI) is a non-invasive microvascular blood flow assessment technique with good temporal and spatial resolution. Most LSCI systems, including commercial devices, can perform only qualitative blood flow evaluation, which is a major limitation of this technique. There are several factors that prevent the utilization of LSCI as a quantitative technique. Among these factors, we can highlight the effect of static scatterers. The goal of this work was to study the influence of differences in static and dynamic scatterer concentration on laser speckle correlation and contrast. In order to achieve this, a laser speckle prototype was developed and tested using an optical phantom with various concentrations of static and dynamic scatterers. It was found that the laser speckle correlation could be used to estimate the relative concentration of static/dynamic scatterers within a sample. Moreover, the speckle correlation proved to be independent of the dynamic scatterer velocity, which is a fundamental characteristic to be used in contrast correction.

  17. Single photon emission tomography in neurological studies: Instrumentation and clinical applications

    NASA Astrophysics Data System (ADS)

    Nikkinen, Paivi Helena

    One triple head and two single head gamma camera systems were used for single photon emission tomography (SPET) imaging of both patients and brain phantoms. Studies with an anatomical brain phantom were performed for evaluation of reconstruction and correction methods in brain perfusion SPET studies. The use of the triple head gamma camera system resulted in a significant increase in image contrast and resolution. This was mainly due to better imaging geometry and the use of a high resolution collimator. The conventional Chang attenuation correction was found suitable for the brain perfusion studies. In the brain perfusion studies region of interest (ROI) based semiquantitation methods were used. A ROI map based on anatomical areas was used in 70 elderly persons (age range 55-85 years) without neurological diseases and in patients suffering from encephalitis or having had a cardiac arrest. Semiquantitative reference values are presented. For the 14 patients with encephalitis the right-to-left side differences were calculated. Defect volume indexes were calculated for 64 patients with brain infarcts. For the 30 cardiac arrest patients the defect percentages and the anteroposterior ratios were used for semiquantitation. It is concluded that different semiquantitation methods are needed for the various patient groups. Age-related reference values will improve the interpretation of SPET data. For validation of the basal ganglia receptor studies measurements were performed using a cylindrical and an anatomical striatal phantom. In these measurements conventional and transmission imaging based non-uniform attenuation corrections were compared. A calibration curve was calculated for the determination of the specific receptor uptake ratio. In the phantom studies using the triple head camera the uptake ratio obtained from simultaneous transmission-emission protocol (STEP) acquisition and iterative reconstruction was closest to the true activity ratio. Conventional acquisition and uniform Chang attenuation correction gave 40% lower values. The effect of dual window scatter correction was also measured. In conventional reconstruction dual window scatter correction increased the uptake ratios when using a single head camera, but when using the triple head camera this correction did not have a significant effect on the ratios. Semiquantitative values for striatal 123I-labelled β-carbomethoxy-3β- (4-iodophenyl)tropane (123I-βCIT) dopamine transporter uptake in 20 adults (mean age 52 +/- 15 years) are presented. The mean basal ganglia to cerebellum ratio was 6.5 +/- 0.9 and the mean caudatus to putamen ratio was 1.2. The registration of brain SPET and magnetic resonance (MR) studies provides the necessary anatomical information for determination of the ROIs. A procedure for registration and simultaneous display of brain SPET and MR images based on six external skin markers is presented. The usefulness of this method was demonstrated in selected patients. The registration accuracy was determined for single and triple head gamma camera systems using brain phantom and simulation studies. The registration residual for three internal test markers was calculated using 4 to 13 external markers in the registration. For 6 external markers, as used in the registration in the patient studies, the mean RMS residuals of the test markers for the single head camera and the triple head camera were 3.5 mm and 3.2 mm, respectively. According to the simulation studies the largest inaccuracy is due mainly to the spatial resolution of SPET. The use of six markers, as in the patient studies, is adequate for accurate registration.

  18. Prediction of Chronic Subdural Hematoma in Minor Head Trauma Patients

    PubMed Central

    Han, Sang-Beom; Song, Shi-Hun; Youm, Jin-Young; Koh, Hyeon-Song; Kim, Seon-Hwan; Kwon, Hyon-Jo

    2014-01-01

    Objective Chronic subdural hematoma (CSDH) is relatively common in neurosurgical field. However not all patients develop CSDH after minor head trauma. In this study, we evaluate the risk factors of post-traumatic CSDH. Methods Two-hundred and seventy-seven patients were enrolled and analyzed in this study from January 2012 to December 2013. Of those, 20 participants had minor head trauma developed CSDH afterward. We also included 257 patients with minor head trauma who did not develop CSDH during the same follow-up period as the control group. We investigated the risk factors related to the development of CSDH after minor head trauma. Results Old age (p=0.014), preexisting diabetes mellitus (p=0.010), hypertension (p=0.026), history of cerebral infarction (p=0.035), antiplatelet agents (p=0.000), acute subdural hematoma in the convexity (p=0.000), encephalomalacia (p=0.029), and long distance between skull and brain parenchyma (p=0.000) were significantly correlated with the development of CSDH after trauma. Multivariate analysis revealed that only the maximum distance between the skull and the cerebral parenchyma was the independent risk factor for the occurrence of CSDH (hazard ratio 2.55, p=0.000). Conclusion We should consider the possibility of developing CSDH in the post-traumatic patients with the identified risk factors. PMID:27169043

  19. Expression and prognostic significance of thymidylate synthase (TS) in pancreatic head and periampullary cancer.

    PubMed

    van der Zee, J A; van Eijck, C H J; Hop, W C J; van Dekken, H; Dicheva, B M; Seynhaeve, A L B; Koning, G A; Eggermont, A M M; Ten Hagen, T L M

    2012-11-01

    Pancreatic cancer has a dismal prognosis. Attempts have been made to improve outcome by several 5-FU based adjuvant treatment regimens. However, the results are conflicting. There seems to be a continental divide with respect to the use of 5-FU based chemoradiotherapy (CRT). Furthermore, evidence has been presented showing a different response of pancreatic head and periampullary cancer to 5-FU based CRT. Expression of thymidylate synthase (TS) has been associated with improved outcome following 5-FU based adjuvant treatment in gastrointestinal cancer. This prompted us to determine the differential expression and prognostic value of TS in pancreatic head and periampullary cancer. TS protein expression was studied by immunohistochemistry on original paraffin embedded tissue from 212 patients following microscopic radical resection (R0) of pancreatic head (n = 98) or periampullary cancer (n = 114). Expression was investigated for associations with recurrence free (RFS), cancer specific (CSS) and overall survival (OS), and conventional prognostic factors. High cytosolic TS expression was present in 26% of pancreatic head tumours and 37% of periampullary tumours (p = .11). Furthermore, TS was an independent factor predicting favourable outcome following curative resection of pancreatic head cancer (p = .003, .001 and .001 for RFS, CSS and OS, respectively). In contrast, in periampullary cancer, TS was not associated with outcome (all p > .10). TS, was found to be poorly expressed in both pancreatic head and periampullary cancer and identified as an independent prognostic factor following curative resection of pancreatic head cancer. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. SU-G-TeP1-08: LINAC Head Geometry Modeling for Cyber Knife System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, B; Li, Y; Liu, B

    Purpose: Knowledge of the LINAC head information is critical for model based dose calculation algorithms. However, the geometries are difficult to measure precisely. The purpose of this study is to develop linac head models for Cyber Knife system (CKS). Methods: For CKS, the commissioning data were measured in water at 800mm SAD. The measured full width at half maximum (FWHM) for each cone was found greater than the nominal value, this was further confirmed by additional film measurement in air. Diameter correction, cone shift and source shift models (DCM, CSM and SSM) are proposed to account for the differences. Inmore » DCM, a cone-specific correction is applied. For CSM and SSM, a single shift is applied to the cone or source physical position. All three models were validated with an in-house developed pencil beam dose calculation algorithm, and further evaluated by the collimator scatter factor (Sc) correction. Results: The mean square error (MSE) between nominal diameter and the FWHM derived from commissioning data and in-air measurement are 0.54mm and 0.44mm, with the discrepancy increasing with cone size. Optimal shift for CSM and SSM is found to be 9mm upward and 18mm downward, respectively. The MSE in FWHM is reduced to 0.04mm and 0.14mm for DCM and CSM (SSM). Both DCM and CSM result in the same set of Sc values. Combining all cones at SAD 600–1000mm, the average deviation from 1 in Sc of DCM (CSM) and SSM is 2.6% and 2.2%, and reduced to 0.9% and 0.7% for the cones with diameter greater than 15mm. Conclusion: We developed three geometrical models for CKS. All models can handle the discrepancy between vendor specifications and commissioning data. And SSM has the best performance for Sc correction. The study also validated that a point source can be used in CKS dose calculation algorithms.« less

  1. Lower limb and associated injuries in frontal-impact road traffic collisions.

    PubMed

    Ammori, Mohannad B; Eid, Hani O; Abu-Zidan, Fikri M

    2016-03-01

    To study the relationship between severity of injury of the lower limb and severity of injury of the head, thoracic, and abdominal regions in frontal-impact road traffic collisions. Consecutive hospitalised trauma patients who were involved in a frontal road traffic collision were prospectively studied over 18 months. Patients with at least one Abbreviated Injury Scale (AIS) ≥3 or AIS 2 injuries within two AIS body regions were included. Patients were divided into two groups depending on the severity of injury to the head, chest or abdomen. Low severity group had an AIS < 2 and high severity group had an AIS ≥ 2. Backward likelihood logistic regression models were used to define significant factors affecting the severity of head, chest or abdominal injuries. Eighty-five patients were studied. The backward likelihood logistic regression model defining independent factors affecting severity of head injuries was highly significant (p =0.01, nagelkerke r square = 0.1) severity of lower limb injuries was the only significant factor (p=0.013) having a negative correlation with head injury (Odds ratio of 0.64 (95% CI: 0.45-0.91). Occupants who sustain a greater severity of injury to the lower limb in a frontal-impact collision are likely to be spared from a greater severity of head injury.

  2. A Backscattering Enhanced Microwave Canopy Scattering Model Based On MIMICS

    NASA Astrophysics Data System (ADS)

    Shen, X.; Hong, Y.; Qin, Q.; Chen, S.; Grout, T.

    2010-12-01

    For modeling microwave scattering of vegetated areas, several microwave canopy scattering models, based on the vectorized radiative transfer equation (VRT) that use different solving techniques, have been proposed in the past three decades. As an iterative solution of VRT at low orders, the Michigan Microwave Canopy Scattering Model (MIMICS) gives an analytical expression for calculating scattering as long as the volume scattering is not too strong. The most important usage of such models is to predict scattering in the backscattering direction. Unfortunately, the simplified assumption of MIMICS is that the scattering between the ground and trunk layers only includes the specular reflection. As a result, MIMICS includes a dominant coherent term which vanishes in the backscattering direction because this term contains a delta function factor of zero in this direction. This assumption needs reconsideration for accurately calculating the backscattering. In the framework of MIMICS, any incoherent terms that involve surface scattering factors must at least undergo surface scattering twice and volume scattering once. Therefore, these incoherent terms are usually very weak. On the other hand, due to the phenomenon of backscattering enhancement, the surface scattering in the backscattering direction is very strong compared to most other directions. Considering the facts discussed above, it is reasonable to add a surface backscattering term to the last equation of the boundary conditions of MIMICS. More terms appear in the final result including a backscattering coherent term which enhances the backscattering. The modified model is compared with the original MIMICS (version 1.0) using JPL/AIRSAR data from NASA Campaign Soil Moisture Experimental 2003 (SMEX03) and Washita92. Significant improvement is observed.

  3. Light scattering properties of spheroidal particles

    NASA Technical Reports Server (NTRS)

    Asano, S.

    1979-01-01

    In the present paper, the light scattering characteristics of spheroidal particles are evaluated within the framework of a scattering theory developed for a homogeneous isotropic spheroid. This approach is shown to be well suited for computing the scattering quantities of spheroidal particles of fairly large sizes (up to a size parameter of 30). The effects of particle size, shape, index of refraction, and orientation on the scattering efficiency factors and the scattering intensity functions are studied and interpreted physically. It is shown that, in the case of oblique incidence, the scattering properties of a long slender prolate spheroid resemble those of an infinitely long circular cylinder.

  4. Impact of Snow Grain Shape and Internal Mixing with Black Carbon Aerosol on Snow Optical Properties for use in Climate Models

    NASA Astrophysics Data System (ADS)

    He, C.; Liou, K. N.; Takano, Y.; Yang, P.; Li, Q.; Chen, F.

    2017-12-01

    A set of parameterizations is developed for spectral single-scattering properties of clean and black carbon (BC)-contaminated snow based on geometric-optic surface-wave (GOS) computations, which explicitly resolves BC-snow internal mixing and various snow grain shapes. GOS calculations show that, compared with nonspherical grains, volume-equivalent snow spheres show up to 20% larger asymmetry factors and hence stronger forward scattering, particularly at wavelengths <1 mm. In contrast, snow grain sizes have a rather small impact on the asymmetry factor at wavelengths <1 mm, whereas size effects are important at longer wavelengths. The snow asymmetry factor is parameterized as a function of effective size, aspect ratio, and shape factor, and shows excellent agreement with GOS calculations. According to GOS calculations, the single-scattering coalbedo of pure snow is predominantly affected by grain sizes, rather than grain shapes, with higher values for larger grains. The snow single-scattering coalbedo is parameterized in terms of the effective size that combines shape and size effects, with an accuracy of >99%. Based on GOS calculations, BC-snow internal mixing enhances the snow single-scattering coalbedo at wavelengths <1 mm, but it does not alter the snow asymmetry factor. The BC-induced enhancement ratio of snow single-scattering coalbedo, independent of snow grain size and shape, is parameterized as a function of BC concentration with an accuracy of >99%. Overall, in addition to snow grain size, both BC-snow internal mixing and snow grain shape play critical roles in quantifying BC effects on snow optical properties. The present parameterizations can be conveniently applied to snow, land surface, and climate models including snowpack radiative transfer processes.

  5. A Field Data Analysis of Risk Factors Affecting the Injury Risks in Vehicle-To-Pedestrian Crashes

    PubMed Central

    Zhang, Guanjun; Cao, Libo; Hu, Jingwen; Yang, King H.

    2008-01-01

    The head, torso, and lower extremity are the most commonly injured body regions during vehicle-to-pedestrian crashes. A total of 312 cases were selected from the National Automotive Sampling System (NASS) Pedestrian Crash Data Study (PCDS) database to investigate factors affecting the likelihood of sustaining MAIS 3+, AIS 3+ head, AIS 3+ torso, and AIS 2+ lower extremity injuries during vehicle-to-pedestrian frontal crashes. The inclusion criteria were pedestrians: (a) aged 14 years or older, (b) with a height of 1.5 m and taller, and (c) who were injured in an upright standing position via vehicle frontal collision. The injury odds ratios (ORs) calculated from logistic regression analyses were used to evaluate the association between selected injury predictors and the odds of sustaining pedestrian head, torso, and lower extremity injuries. These predictors included a crash factor (impact speed), pedestrian factors (age, gender, height, and weight), and vehicle factors (front bumper central height, front bumper lead, ground to front/top transition point height (FTTPH), and rear hood opening distance (RHOD)). Results showed that impact speed was a statistically significant predictor for head, torso, and lower extremity injury odds, as expected. Comparison of people 65 years of age and older to young adults aged 14 to 64 showed that age was also a significant predictor for torso (p<0.001, OR=23.8) and lower extremity (p=0.020, OR=2.44) injury odds, but not for head injuries (p=0.661). Vehicles with higher FTTPH and more vertical frontal structures were aggressive to pedestrians, especially regarding injuries to the torso. A very short RHOD would be more likely to lead the pedestrian to impact the windshield and windshield frame, thus increasing the head injury risk. PMID:19026237

  6. Self-reported Concussion History and Sensorimotor Tests Predict Head/Neck Injuries.

    PubMed

    Hides, Julie A; Franettovich Smith, Melinda M; Mendis, M Dilani; Treleaven, Julia; Rotstein, Andrew H; Sexton, Christopher T; Low Choy, Nancy; McCrory, Paul

    2017-12-01

    Sport-related concussion (SRC) is a risk for players involved in high-impact, collision sports. A history of SRC is a risk factor for future concussions, but the mechanisms underlying this are unknown. Despite evidence that most visible signs and symptoms associated with sports concussion resolve within 7-10 d, it has been proposed that subclinical loss of neuromuscular control and impaired motor functioning may persist and be associated with further injury. Alternatively, indicators of poor sensorimotor performance could be independent risk factors. This study investigated if a history of SRC and/or preseason sensorimotor performance predicted season head/neck injuries. A total of 190 male rugby league, rugby union, and Australian Football League players participated. Preseason assessments included self-report of SRC within the previous 12 months and a suite of measures of sensorimotor function (balance, vestibular function, cervical proprioception, and trunk muscle function). Head/neck injury data were collected in the playing season. Forty-seven players (25%) reported a history of SRC. A history of concussion was related to changes in size and contraction of trunk muscles. Twenty-two (11.6%) players sustained a head/neck injury during the playing season, of which, 14 (63.6%) players had a history of SRC. Predictors of in-season head/neck injuries included history of SRC, trunk muscle function, and cervical proprioceptive errors. Five risk factors were identified, and players with three or more of these had 14 times greater risk of sustaining a season neck/head injury (sensitivity of 75% and specificity of 82.5%) than did players with two or fewer risk factors. The modifiable risk factors identified could be used to screen football players in the preseason and guide the development of exercise programs aimed at injury reduction.

  7. CPP magnetoresistance of magnetic multilayers: A critical review

    NASA Astrophysics Data System (ADS)

    Bass, Jack

    2016-06-01

    We present a comprehensive, critical review of data and analysis of Giant (G) Magnetoresistance (MR) with Current-flow Perpendicular-to-the-layer-Planes (CPP-MR) of magnetic multilayers [F/N]n (n=number of repeats) composed of alternating nanoscale layers of ferromagnetic (F) and non-magnetic (N) metals, or of spin-valves that allow control of anti-parallel (AP) and parallel (P) orientations of the magnetic moments of adjacent F-layers. GMR, a large change in resistance when an applied magnetic field changes the moment ordering of adjacent F-layers from AP to P, was discovered in 1988 in the geometry with Current flow in the layer-Planes (CIP). The CPP-MR has two advantages over the CIP-MR: (1) relatively simple two-current series-resistor (2CSR) and more general Valet-Fert (VF) models allow more direct access to the underlying physics; and (2) it is usually larger, which should be advantageous for devices. When the first CPP-MR data were published in 1991, it was not clear whether electronic transport in GMR multilayers is completely diffusive or at least partly ballistic. It was not known whether the properties of layers and interfaces would vary with layer thickness or number. It was not known whether the CPP-MR would be dominated by scattering within the F-metals or at the F/N interfaces. Nothing was known about: (1) spin-flipping within F-metals, characterized by a spin-diffusion length, lsfF; (2) interface specific resistances (AR=area A times resistance R) for N1/N2 interfaces; (3) interface specific resistances and interface spin-dependent scattering asymmetry at F/N and F1/F2 interfaces; and (4) spin-flipping at F/N, F1/F2 and N1/N2 interfaces. Knowledge of spin-dependent scattering asymmetries in F-metals and F-alloys, and of spin-flipping in N-metals and N-alloys, was limited. Since 1991, CPP-MR measurements have quantified the scattering and spin-flipping parameters that determine GMR for a wide range of F- and N-metals and alloys and of F/N pairs. This review is designed to provide a history of how knowledge of CPP-MR parameters grew, to give credit for discoveries, to explain how combining theory and experiment has enabled extraction of quantitative information about these parameters, but also to make clear that progress was not always direct and to point out where disagreements still exist. To limit its length, the review considers only collinear orientations of the moments of adjacent F-layers. To aid readers looking for specific information, we have provided an extensive table of contents and a detailed summary. Together, these should help locate over 100 figures plus 17 tables that collect values of individual parameters. In 1997, CIP-MR replaced anisotropic MR (AMR) as the sensor in read heads of computer hard drives. In principle, the usually larger CPP-MR was a contender for the next generation read head sensor. But in 2003, CIP-MR was replaced by the even larger Tunneling MR (TMR), which has remained the read-head sensor ever since. However, as memory bits shrink to where the relatively large specific resistance AR of TMR gives too much noise and too large an R to impedance match as a read-head sensor, the door is again opened for CPP-MR. We will review progress in finding techniques and F-alloys and F/N pairs to enhance the CPP-MR, and will describe its present capabilities.

  8. Channel heads in mountain catchments subject to human impact - The Skrzyczne range in Southern Poland

    NASA Astrophysics Data System (ADS)

    Wrońska-Wałach, Dominika; Żelazny, Mirosław; Małek, Stanisław; Krakowian, Katarzyna; Dąbek, Natalia

    2018-05-01

    Channel heads in mountain catchments are increasingly influenced by human activity. The disturbance of mountain headwater areas in moderate latitudes by the clearing of trees and the associated logging, road building and hydrotechnical constructions contribute to changes in the water cycle and consequently may induce a change in channel head development. Here we examine channel heads in the Beskid Śląski Mts., one of the areas most affected by ecological disaster in the Polish Flysch Carpathians. An ecological disaster associated with the decline of spruce trees in the 1980s and 1990s caused a substantial decrease (of about 50%) in the land area occupied by spruce forest in the Beskid Śląski Mts. As a result, headwater areas were subject to multidirectional changes in the environment. The purpose of this paper is to determine the detailed characteristics of channel heads currently developing in the analyzed headwater areas, as well as to identify independent factors that affect the evolution of channel heads. Geomorphological mapping was conducted in 2012 in the vicinity of springs in the study area. One-way ANOVA was used to determine the significance of differences between mean values calculated for groups identified based on: i) geomorphologic processes (hollows with rock veneer - h, spring niches - sn, gullies - g), ii) location vs. transformation of channel heads (forested areas vs., deforested areas with road constructions). Principal component analysis (PCA) was used to determine the structure and general patterns associated with relationships between the parameters of a channel head and its contribution area, as well as to identify and interpret new (orthogonal) spaces defined using distinct factors. As far as we know, this kind of approach has been never applied before. A total of 80 channel heads surrounding 104 springs were surveyed close to the main ridge in the study area. A total of 14 morphometric parameters were taken into account in this study. The analyzed landforms substantially differ from one another in relation to groups identified based on morphogenetic processes and with respect to time. Multidimensional PCA analysis made it possible to identify three independent, main factors that together explain 81.9% of total variance. It was concluded that the major factor today is human impact, which alters natural geomorphic processes. The second factor is connected with the type of water circulation. The third factor, which explains only 12.7% of variance, is a geologic factor defined in terms of structural integrity. Although our results are region-specific, at least some general conclusions may be drawn. The main general conclusion is that multidimensional human impact may lead to an increase in the fragmentation of mountain headwater areas over the long term.

  9. UAV-Assisted Dynamic Clustering of Wireless Sensor Networks for Crop Health Monitoring

    PubMed Central

    Ammad Uddin, Mohammad; Mansour, Ali; Le Jeune, Denis; Ayaz, Mohammad; Aggoune, el-Hadi M.

    2018-01-01

    In this study, a crop health monitoring system is developed by using state of the art technologies including wireless sensors and Unmanned Aerial Vehicles (UAVs). Conventionally data is collected from sensor nodes either by fixed base stations or mobile sinks. Mobile sinks are considered a better choice nowadays due to their improved network coverage and energy utilization. Usually, the mobile sink is used in two ways: either it goes for random walk to find the scattered nodes and collect data, or follows a pre-defined path established by the ground network/clusters. Neither of these options is suitable in our scenario due to the factors like dynamic data collection, the strict targeted area required to be scanned, unavailability of a large number of nodes, dynamic path of the UAV, and most importantly, none of these are known in advance. The contribution of this paper is the formation of dynamic runtime clusters of field sensors by considering the above mentioned factors. Furthermore a mechanism (Bayesian classifier) is defined to select best node as cluster head. The proposed system is validated through simulation results, lab and infield experiments using concept devices. The obtained results are encouraging, especially in terms of deployment time, energy, efficiency, throughput and ease of use. PMID:29439496

  10. UAV-Assisted Dynamic Clustering of Wireless Sensor Networks for Crop Health Monitoring.

    PubMed

    Uddin, Mohammad Ammad; Mansour, Ali; Jeune, Denis Le; Ayaz, Mohammad; Aggoune, El-Hadi M

    2018-02-11

    In this study, a crop health monitoring system is developed by using state of the art technologies including wireless sensors and Unmanned Aerial Vehicles (UAVs). Conventionally data is collected from sensor nodes either by fixed base stations or mobile sinks. Mobile sinks are considered a better choice nowadays due to their improved network coverage and energy utilization. Usually, the mobile sink is used in two ways: either it goes for random walk to find the scattered nodes and collect data, or follows a pre-defined path established by the ground network/clusters. Neither of these options is suitable in our scenario due to the factors like dynamic data collection, the strict targeted area required to be scanned, unavailability of a large number of nodes, dynamic path of the UAV, and most importantly, none of these are known in advance. The contribution of this paper is the formation of dynamic runtime clusters of field sensors by considering the above mentioned factors. Furthermore a mechanism (Bayesian classifier) is defined to select best node as cluster head. The proposed system is validated through simulation results, lab and infield experiments using concept devices. The obtained results are encouraging, especially in terms of deployment time, energy, efficiency, throughput and ease of use.

  11. Radiative heat transfer in strongly forward scattering media using the discrete ordinates method

    NASA Astrophysics Data System (ADS)

    Granate, Pedro; Coelho, Pedro J.; Roger, Maxime

    2016-03-01

    The discrete ordinates method (DOM) is widely used to solve the radiative transfer equation, often yielding satisfactory results. However, in the presence of strongly forward scattering media, this method does not generally conserve the scattering energy and the phase function asymmetry factor. Because of this, the normalization of the phase function has been proposed to guarantee that the scattering energy and the asymmetry factor are conserved. Various authors have used different normalization techniques. Three of these are compared in the present work, along with two other methods, one based on the finite volume method (FVM) and another one based on the spherical harmonics discrete ordinates method (SHDOM). In addition, the approximation of the Henyey-Greenstein phase function by a different one is investigated as an alternative to the phase function normalization. The approximate phase function is given by the sum of a Dirac delta function, which accounts for the forward scattering peak, and a smoother scaled phase function. In this study, these techniques are applied to three scalar radiative transfer test cases, namely a three-dimensional cubic domain with a purely scattering medium, an axisymmetric cylindrical enclosure containing an emitting-absorbing-scattering medium, and a three-dimensional transient problem with collimated irradiation. The present results show that accurate predictions are achieved for strongly forward scattering media when the phase function is normalized in such a way that both the scattered energy and the phase function asymmetry factor are conserved. The normalization of the phase function may be avoided using the FVM or the SHDOM to evaluate the in-scattering term of the radiative transfer equation. Both methods yield results whose accuracy is similar to that obtained using the DOM along with normalization of the phase function. Very satisfactory predictions were also achieved using the delta-M phase function, while the delta-Eddington phase function and the transport approximation may perform poorly.

  12. Aerosol optical properties at rural background area in Western Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Lihavainen, H.; Alghamdi, M. A.; Hyvärinen, A.; Hussein, T.; Neitola, K.; Khoder, M.; Abdelmaksoud, A. S.; Al-Jeelani, H.; Shabbaj, I. I.; Almehmadi, F. M.

    2017-11-01

    To derive the comprehensive aerosol in situ characteristics at a rural background area in Saudi Arabia, an aerosol measurements station was established to Hada Al Sham, 60 km east from the Red Sea and the city of Jeddah. The present sturdy describes the observational data from February 2013 to February 2015 of scattering and absorption coefficients, Ångström exponents and single scattering albedo over the measurement period. The average scattering and absorption coefficients at wavelength 525 nm were 109 ± 71 Mm- 1 (mean ± SD, at STP conditions) and 15 ± 17 Mm- 1 (at STP conditions), respectively. As expected, the scattering coefficient was dominated by large desert dust particles with low Ångström scattering exponent, 0.49 ± 0.62. Especially from February to June the Ångström scattering exponent was clearly lower (0.23) and scattering coefficients higher (124 Mm- 1) than total averages because of the dust outbreak season. Aerosol optical properties had clear diurnal cycle. The lowest scattering and absorption coefficients and aerosol optical depths were observed around noon. The observed diurnal variation is caused by wind direction and speed, during night time very calm easterly winds are dominating whereas during daytime the stronger westerly winds are dominating (sea breeze). Positive Matrix Factorization mathematical tool was applied to the scattering and absorption coefficients and PM2.5 and coarse mode (PM10-PM2.5) mass concentrations to identify source characteristics. Three different factors with clearly different properties were found; anthropogenic, BC source and desert dust. Mass absorption efficiencies for BC source and desert dust factors were, 6.0 m2 g- 1 and 0.4 m2 g- 1, respectively, and mass scattering efficiencies for anthropogenic (sulphate) and desert dust, 2.5 m2 g- 1 and 0.8 m2 g- 1, respectively.

  13. Small-angle scattering from 3D Sierpinski tetrahedron generated using chaos game

    NASA Astrophysics Data System (ADS)

    Slyamov, Azat

    2017-12-01

    We approximate a three dimensional version of deterministic Sierpinski gasket (SG), also known as Sierpinski tetrahedron (ST), by using the chaos game representation (CGR). Structural properties of the fractal, generated by both deterministic and CGR algorithms are determined using small-angle scattering (SAS) technique. We calculate the corresponding monodisperse structure factor of ST, using an optimized Debye formula. We show that scattering from CGR of ST recovers basic fractal properties, such as fractal dimension, iteration number, scaling factor, overall size of the system and the number of units composing the fractal.

  14. Aseptic necrosis of the femoral head after pregnancy: a case report.

    PubMed

    Nassar, Kawtar; Rachidi, Wafae; Janani, Saadia; Mkinsi, Ouafa

    2016-01-01

    A documented case of beginning aseptic necrosis of the femoral head associated with pregnancy together with a review of the literature about this rare complication of pregnancy is presented. The known risk factors of osteonecrosis are; steroid use, alcoholism, organ transplantation, especially after kidney transplant or bone marrow transplantation bone, systemic lupus erythematosus, dyslipidemia especially hypertriglyceridemia, dysbaric decompression sickness, drepanocytosis and Gaucher's disease. Among the less established factors, we mention procoagulations abnormalities, HIV infection, chemotherapy. We report a case of osteonecrosis of femoral head after pregnancy.

  15. Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics.

    PubMed

    Jain, Amit; Kuhls-Gilcrist, Andrew T; Gupta, Sandesh K; Bednarek, Daniel R; Rudin, Stephen

    2010-03-01

    The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick CsI) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300-micron thick CsI). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks.

  16. An empirical model for polarized and cross-polarized scattering from a vegetation layer

    NASA Technical Reports Server (NTRS)

    Liu, H. L.; Fung, A. K.

    1988-01-01

    An empirical model for scattering from a vegetation layer above an irregular ground surface is developed in terms of the first-order solution for like-polarized scattering and the second-order solution for cross-polarized scattering. The effects of multiple scattering within the layer and at the surface-volume boundary are compensated by using a correction factor based on the matrix doubling method. The major feature of this model is that all parameters in the model are physical parameters of the vegetation medium. There are no regression parameters. Comparisons of this empirical model with theoretical matrix-doubling method and radar measurements indicate good agreements in polarization, angular trends, and k sub a up to 4, where k is the wave number and a is the disk radius. The computational time is shortened by a factor of 8, relative to the theoretical model calculation.

  17. Local Intensity Enhancements in Spherical Microcavities: Implications for Photonic Chemical and Biological Sensors

    NASA Technical Reports Server (NTRS)

    Fuller, Kirk A.

    2005-01-01

    In this report, we summarize recent findings regarding the use spherical microcavities in the amplification of light that is inelastically scattered by either fluorescent or Raman-active molecules. This discussion will focus on Raman scattering, with the understanding that analogous processes apply to fluorescence. Raman spectra can be generated through the use of a very strong light source that stimulates inelastic light scattering by molecules, with the scattering occurring at wavelengths shifted from that of the source and being most prominent at shifts associated with the molecules natural vibrational frequencies. The Raman signal can be greatly enhanced by exposing a molecule to the intense electric fields that arise near surfaces (typically of gold or silver) exhibiting nanoscale roughness. This is known as surface-enhanced Raman scattering (SERS). SERS typically produces gain factors of 103 - 106, but under special conditions, factors of 1010 - 1014 have been achieved.

  18. Atomic Scattering Factor of the ASTRO-H (Hitomi) SXT Reflector Around the Gold's L Edges

    NASA Technical Reports Server (NTRS)

    Kikuchi, Naomichi; Kurashima, Sho; Ishida, Manabu; Iizuka, Ryo; Maeda, Yoshitomo; Hayashi, Takayuki; Okajima, Takashi; Matsumoto, Hironori; Mitsubishi, Ikuyuki; Saji, Shigetaka

    2016-01-01

    The atomic scattering factor in the energy range of 11.2 - 15.4 keV for the ASTRO-H Soft X-ray Telescope (SXT) is reported. The large effective area of the SXT makes use of photon spectra above 10 keV viable, unlike most other X-ray satellites with total-reflection mirror optics. Presence of gold's L-edges in the energy band is a major issue, as it complicates the function of the effective area. In order to model the area, the reflectivity measurements in the 11.2 - 15.4 keV band with the energy pitch of 0.4 - 0.7 eV were made in the synchrotron beam-line Spring-8 BL01B1. We obtained atomic scattering factors f1 and f2 by the curve fitting to the reflectivities of our witness sample. The edges associated with the L-I, II, and III transitions are identified, of which the depths are found to be roughly 60 shallower than those expected from the Henkes atomic scattering factor.

  19. Factors Associated with Head Start Staff Participation in Classroom-Based Professional Development

    ERIC Educational Resources Information Center

    Trivette, Carol M.; Raab, Melinda; Dunst, Carl J.

    2014-01-01

    Factors associated with Head Start staff participation in a classroom-based professional development project to promote their use of evidence-based child learning opportunity practices and evidence-based responsive teaching procedures were examined in a study of 36 teachers and teacher assistants in 19 different classrooms. The factors…

  20. High-fidelity artifact correction for cone-beam CT imaging of the brain

    NASA Astrophysics Data System (ADS)

    Sisniega, A.; Zbijewski, W.; Xu, J.; Dang, H.; Stayman, J. W.; Yorkston, J.; Aygun, N.; Koliatsos, V.; Siewerdsen, J. H.

    2015-02-01

    CT is the frontline imaging modality for diagnosis of acute traumatic brain injury (TBI), involving the detection of fresh blood in the brain (contrast of 30-50 HU, detail size down to 1 mm) in a non-contrast-enhanced exam. A dedicated point-of-care imaging system based on cone-beam CT (CBCT) could benefit early detection of TBI and improve direction to appropriate therapy. However, flat-panel detector (FPD) CBCT is challenged by artifacts that degrade contrast resolution and limit application in soft-tissue imaging. We present and evaluate a fairly comprehensive framework for artifact correction to enable soft-tissue brain imaging with FPD CBCT. The framework includes a fast Monte Carlo (MC)-based scatter estimation method complemented by corrections for detector lag, veiling glare, and beam hardening. The fast MC scatter estimation combines GPU acceleration, variance reduction, and simulation with a low number of photon histories and reduced number of projection angles (sparse MC) augmented by kernel de-noising to yield a runtime of ~4 min per scan. Scatter correction is combined with two-pass beam hardening correction. Detector lag correction is based on temporal deconvolution of the measured lag response function. The effects of detector veiling glare are reduced by deconvolution of the glare response function representing the long range tails of the detector point-spread function. The performance of the correction framework is quantified in experiments using a realistic head phantom on a testbench for FPD CBCT. Uncorrected reconstructions were non-diagnostic for soft-tissue imaging tasks in the brain. After processing with the artifact correction framework, image uniformity was substantially improved, and artifacts were reduced to a level that enabled visualization of ~3 mm simulated bleeds throughout the brain. Non-uniformity (cupping) was reduced by a factor of 5, and contrast of simulated bleeds was improved from ~7 to 49.7 HU, in good agreement with the nominal blood contrast of 50 HU. Although noise was amplified by the corrections, the contrast-to-noise ratio (CNR) of simulated bleeds was improved by nearly a factor of 3.5 (CNR = 0.54 without corrections and 1.91 after correction). The resulting image quality motivates further development and translation of the FPD-CBCT system for imaging of acute TBI.

  1. Inelastic X-ray scattering of RTAl3 (R = La, Ce, T = Cu, Au)

    NASA Astrophysics Data System (ADS)

    Tsutsui, Satoshi; Kaneko, Koji; Pospisil, Jiri; Haga, Yoshinori

    2018-05-01

    Inelastic X-ray scattering (IXS) experiments of RTAl3 (R = La Ce, T = Cu, Au) were carried out at 300 and 5.5 K. The spectra between LaCuAl3 and CeCuAl3 (LaAuAl3 and CeAuAl3) are nearly identical at both temperatures except for temperature factors such as temperature dependence of Bose factor in IXS spectra and effect on thermal expansion. This means that no evident temperature dependence of IXS spectra was observed in CeTAl3 (T = Cu, Au). Since the major contribution of scattering cross section in IXS measurements is Thomson scattering, the present results failed to confirm the presence of vibron in these compounds.

  2. SU-C-209-03: Anti-Scatter Grid-Line Artifact Minimization for Removing the Grid Lines for Three Different Grids Used with a High Resolution CMOS Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rana, R; Bednarek, D; Rudin, S

    Purpose: Demonstrate the effectiveness of an anti-scatter grid artifact minimization method by removing the grid-line artifacts for three different grids when used with a high resolution CMOS detector. Method: Three different stationary x-ray grids were used with a high resolution CMOS x-ray detector (Dexela 1207, 75 µm pixels, sensitivity area 11.5cm × 6.5cm) to image a simulated artery block phantom (Nuclear Associates, Stenosis/Aneurysm Artery Block 76–705) combined with a frontal head phantom used as the scattering source. The x-ray parameters were 98kVp, 200mA, and 16ms for all grids. With all the three grids, two images were acquired: the first formore » a scatter-less flat field including the grid and the second of the object with the grid which may still have some scatter transmission. Because scatter has a low spatial frequency distribution, it was represented by an estimated constant value as an initial approximation and subtracted from the image of the object with grid before dividing by an average frame of the grid flat-field with no scatter. The constant value was iteratively changed to minimize residual grid-line artifact. This artifact minimization process was used for all the three grids. Results: Anti-scatter grid lines artifacts were successfully eliminated in all the three final images taken with the three different grids. The image contrast and CNR were also compared before and after the correction, and also compared with those from the image of the object when no grid was used. The corrected images showed an increase in CNR of approximately 28%, 33% and 25% for the three grids, as compared to the images when no grid at all was used. Conclusion: Anti-scatter grid-artifact minimization works effectively irrespective of the specifications of the grid when it is used with a high spatial resolution detector. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less

  3. Seed release by invasive thistles: the impact of plant and environmental factors

    PubMed Central

    Jongejans, Eelke; Pedatella, Nicholas M; Shea, Katriona; Skarpaas, Olav; Auhl, Richard

    2007-01-01

    Dispersal is a key process in biological studies of spatial dynamics, but the initiation of dispersal has often been neglected, despite strong indications that differential timing of dispersal can significantly affect dispersal distances. To investigate which plant and environmental factors determine the release of plumed seeds by the invasive thistles Carduus acanthoides and Carduus nutans, we exposed 192 flower heads of each species to increasing wind speeds in a full-factorial wind tunnel experiment with four air flow turbulence, three flower head wetness and two flower head temperature levels. The number of seed releases was highest under dry and turbulent conditions and from heads that had already lost a considerable number of seeds, but was not affected by flower head size, head angle or temperature. Inspection of the trials on video showed that higher wind speeds were needed to meet the seed release threshold in laminar flows and for C. acanthoides heads that had been wet for a longer time. Species differences were minimal, although seed release was more sensitive to lower levels of turbulence in the larger-headed and more open C. nutans heads. Knowledge of seed release biases towards weather conditions favourable for long-distance dispersal improves our understanding of the spread of invaders and allows managers to increase the efficiency of their containment strategies by applying them at crucial times. PMID:17666379

  4. Influence of anthropometry on the kinematics of the cervical spine and the risk of injury in sled tests in female volunteers.

    PubMed

    Dehner, Christoph; Schick, Sylvia; Arand, Markus; Elbel, Martin; Hell, Wolfram; Kramer, Michael

    2008-07-01

    The objective of this study was to investigate the influence of anthropometric data on the kinematics of the cervical spine and the risk factors for sustaining a neck injury during rear-end collisions occurring in a sled test. A rear-end collision with a velocity change (DeltaV) of 6.3 km/h was simulated in a sled test with eight healthy female subjects. The study analysed the association of anthropometric data with the initial distance between the head and the head restraint, defined kinematic characteristics, the neck injury criterion (NIC) and the neck injury criterion minor (NICmin). The head circumference is negatively associated (r=-0.598) with the initial distance between the head and the head restraint, the maximal head extension (r=-0.687) and the maximal dorsal angular head acceleration (r=-0.633). The body weight (r=0.800), body height (r=0.949) and thorax circumference (r=0.632) are positively associated with the maximal ventral head translation. The neck length correlates positively with the NIC (r=0.826) and negatively with the NICmin (r=-0.797). Anthropometric factors influence the kinematics of the cervical spine and the risk of injury. A high risk of injury may be assumed for individuals with a small head circumference, long neck, tall body height and high body weight.

  5. [Drugs and pharmacists for the army, 1800-1815].

    PubMed

    Trépardoux, Francis

    2014-01-01

    SUMMARY During this period, the authority was exerted by Parmentier, as the head and chief pharmacist for the French armies. For the military hospitals scattered all over Europe, he organised the pharmacies services rules, with technical and financial concerns. The first aid devices on the battlefield included a special box for pharmacy containing ressucitation and siccative items for the wounds, and immediately available for the surgeon's use. The qualified pharmacy staff exhibited large variations, from 200 to 1.100 people in 1812.

  6. Sensitivity analysis of some critical factors affecting simulated intrusion volumes during a low pressure transient event in a full-scale water distribution system.

    PubMed

    Ebacher, G; Besner, M C; Clément, B; Prévost, M

    2012-09-01

    Intrusion events caused by transient low pressures may result in the contamination of a water distribution system (DS). This work aims at estimating the range of potential intrusion volumes that could result from a real downsurge event caused by a momentary pump shutdown. A model calibrated with transient low pressure recordings was used to simulate total intrusion volumes through leakage orifices and submerged air vacuum valves (AVVs). Four critical factors influencing intrusion volumes were varied: the external head of (untreated) water on leakage orifices, the external head of (untreated) water on submerged air vacuum valves, the leakage rate, and the diameter of AVVs' outlet orifice (represented by a multiplicative factor). Leakage orifices' head and AVVs' orifice head levels were assessed through fieldwork. Two sets of runs were generated as part of two statistically designed experiments. A first set of 81 runs was based on a complete factorial design in which each factor was varied over 3 levels. A second set of 40 runs was based on a latin hypercube design, better suited for experimental runs on a computer model. The simulations were conducted using commercially available transient analysis software. Responses, measured by total intrusion volumes, ranged from 10 to 366 L. A second degree polynomial was used to analyze the total intrusion volumes. Sensitivity analyses of both designs revealed that the relationship between the total intrusion volume and the four contributing factors is not monotonic, with the AVVs' orifice head being the most influential factor. When intrusion through both pathways occurs concurrently, interactions between the intrusion flows through leakage orifices and submerged AVVs influence intrusion volumes. When only intrusion through leakage orifices is considered, the total intrusion volume is more largely influenced by the leakage rate than by the leakage orifices' head. The latter mainly impacts the extent of the area affected by intrusion. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. A human factors approach to snowsport safety: Novel research on pediatric participants' behaviors and head injury risk.

    PubMed

    Dickson, Tracey J; Trathen, Stephen; Waddington, Gordon; Terwiel, F Anne; Baltis, Daniel

    2016-03-01

    This study applied a human factors approach to snowsport resort systems to contribute to the understanding of the incidence and severity of pediatric snowsport head accelerations. Previous research indicates low magnitude head accelerations are common among snowsport participants. This study adds to the knowledge of snowsport safety by measuring aspects of participants' snowsport behavior and linking this with head acceleration data. School-aged students (n = 107) wore telemetry-fitted helmets and Global Positioning System (GPS) devices during snowsport activity. Data was collected over 159 sessions (total hours 701). Head accelerations recorded by the telemetry units were compared with GPS-generated data. This study found speeds attained normally exceed the testing rating for which helmets are designed; lower rates of head accelerations compared to earlier studies and that when head accelerations did occur they were generally below the threshold for concussions. Pediatric snowsport head accelerations are rare and are generally of low magnitude. Those most at risk of a head acceleration >40 g were male snowboarders. Given the recorded speeds in first time participants, increased targeting of novice snowsport participants to encourage education about the use of protective equipment, including helmets, is warranted. Post event recall was not a good indicator of having experienced a head impact. Consideration should be given to raising the standard design speed testing for snowsport helmet protective devices to reflect actual snowsport behaviors. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. Socioeconomic status, family background and other key factors influence the management of head lice in Norway.

    PubMed

    Rukke, Bjørn Arne; Soleng, Arnulf; Lindstedt, Heidi Heggen; Ottesen, Preben; Birkemoe, Tone

    2014-05-01

    How head lice infestations are managed by households is an important but generally neglected issue in head lice research. In the present study, we investigate actions taken against head lice by Norwegian households in association with socioeconomic status, family background, school-related variables and other key factors. Repeat questionnaires distributed to caretakers of the same elementary school children during a 2-year period enabled us to study both previous head lice management and any changes in this management through time. Households from 12 schools spanning the main socioeconomic variation found in Norway participated in the study. All students with active head lice infestation were treated in the four investigated periods. Most caretakers used a thorough head lice checking technique and informed others of own infestation. Checking frequency was low as most children were inspected less than monthly. The best determinant of increased checking frequency and thoroughness was personal experience with head lice. The increased awareness, however, seemed to be somewhat short-lived, as there was a decrease in checking frequency and thoroughness within 1 year after infestation. Personal experience with head lice also increased general knowledge related to the parasite. Parents born in developing countries checked their children for head lice more frequently, although less thoroughly, informed fewer contacts when infested, used pediculicides preventively more often and knew less about head lice than parents born in developed countries. Households with highly educated mothers had a lower checking frequency, but their knowledge and willingness to inform others was high. Single parents were more concerned about economic costs and kept children home from school longer while infested than other parents. As head lice management varied among socioeconomic groups and with parental background, differentiated advice should be considered in the control of head lice. The biannual focus on head lice during the 2 years of investigation increased checking thoroughness, while checking frequency remained unchanged. Based on the results, we suggest new head lice management guidelines for health authorities.

  9. Heading and head injuries in soccer.

    PubMed

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the head, verify the exposure to heading at all ages and competitive levels, determine stable estimates of concussive injury rates across the soccer spectrum, conduct prospective longitudinal studies on soccer players focusing on exposure, injury and cognition, and determine the minimum safe age to begin instruction on the skill of heading. Only then will we be able to speak with some authority on the issue of heading and head injuries in soccer.

  10. High-level expression and deuteration of sperm whale myoglobin: A study of its solvent structure by X-ray and neutron diffraction methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu, F.; Ramakrishnan, V.; Schoenborn, B.P.

    1994-12-31

    Neutron diffraction has become one of the best ways to study light atoms, such as hydrogens. Hydrogen however has a negative coherent scattering factor, and a large incoherent scattering factor, while deuterium has virtually no incoherent scattering, but a large positive coherent scattering factor. Beside causing high background due to its incoherent scattering, the negative coherent scattering of hydrogen tends to cancel out the positive contribution from other atoms in a neutron density map. Therefore a fully deuterated sample will yield better diffraction data with stronger density in the hydrogen position. On this basis, a sperm whale myoglobin gene modifiedmore » to include part of the A cII protein gene has been cloned into the T7 expression system. Milligram amounts of fully deuterated holo-myoglobin have been obtained and used for crystallization. The synthetic sperm whale myoglobin crystallized in P2{sub 1} space group isomorphous with the native protein crystal. A complete X-ray diffraction dataset at 1.5{Angstrom} has been collected. This X-ray dataset, and a neutron data set collected previously on a protonated carbon-monoxymyoglobin crystal have been used for solvent structure studies. Both X-ray and neutron data have shown that there are ordered hydration layers around the protein surface. Solvent shell analysis on the neutron data further has shown that the first hydration layer behaves differently around polar and apolar regions of the protein surface. Finally, the structure of per-deuterated myoglobin has been refined using all reflections to a R factor of 17%.« less

  11. Impact of reconstruction parameters on quantitative I-131 SPECT

    NASA Astrophysics Data System (ADS)

    van Gils, C. A. J.; Beijst, C.; van Rooij, R.; de Jong, H. W. A. M.

    2016-07-01

    Radioiodine therapy using I-131 is widely used for treatment of thyroid disease or neuroendocrine tumors. Monitoring treatment by accurate dosimetry requires quantitative imaging. The high energy photons however render quantitative SPECT reconstruction challenging, potentially requiring accurate correction for scatter and collimator effects. The goal of this work is to assess the effectiveness of various correction methods on these effects using phantom studies. A SPECT/CT acquisition of the NEMA IEC body phantom was performed. Images were reconstructed using the following parameters: (1) without scatter correction, (2) with triple energy window (TEW) scatter correction and (3) with Monte Carlo-based scatter correction. For modelling the collimator-detector response (CDR), both (a) geometric Gaussian CDRs as well as (b) Monte Carlo simulated CDRs were compared. Quantitative accuracy, contrast to noise ratios and recovery coefficients were calculated, as well as the background variability and the residual count error in the lung insert. The Monte Carlo scatter corrected reconstruction method was shown to be intrinsically quantitative, requiring no experimentally acquired calibration factor. It resulted in a more accurate quantification of the background compartment activity density compared with TEW or no scatter correction. The quantification error relative to a dose calibrator derived measurement was found to be  <1%,-26% and 33%, respectively. The adverse effects of partial volume were significantly smaller with the Monte Carlo simulated CDR correction compared with geometric Gaussian or no CDR modelling. Scatter correction showed a small effect on quantification of small volumes. When using a weighting factor, TEW correction was comparable to Monte Carlo reconstruction in all measured parameters, although this approach is clinically impractical since this factor may be patient dependent. Monte Carlo based scatter correction including accurately simulated CDR modelling is the most robust and reliable method to reconstruct accurate quantitative iodine-131 SPECT images.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haseeb, Syed Abdul; Ahmad, Syed Bilal; Mirza, Sika

    Purpose: To assess the impact of radiation treatment delivery through patient inhomogeneities on the secondary barrier shielding requirements in IMRT treatments using Monte Carlo Simulations. Materials and Methods: Scatter factors were calculated at a distance of 1m from the center of a virtual phantom in Geant4.10.01. Phantom (30×30×30 cm{sup 3}) was inserted with lung (30×30×8 cm{sup 3}), stainless steel (5×5×5 cm{sup 3}) and aluminum (5×5×5 cm{sup 3}) to represent the inhomogeneities. Scatter factor was defined according to the NCRP-151 recommendations and was calculated for angles of 3° to 120° with respect to the beam’s central axis. A virtual radiation source,more » with energy sampled from a histogram representing 6 MV FFF beam, was used for irradiation with a field size of 15×15 cm{sup 2} and SSD of 100 cm. Results: Irradiation through the inhomogeneity affects the patient scattered dose. For high Z material inhomogeneities the scattered dose is reduced due to significant attenuation of the primary radiation. On the other hand if the inhomogeneity is a low Z material such as lung the scattered dose is higher by a maximum of 26%. The average increase in scatter factors for the lung phantom was 17% for angles between 3° and 63° compared to the homogeneous water phantom. Conclusions: In IMRT type treatments delivered through low density patient inhomogeneities (lung) the scattered dose increases significantly. Considering a large proportion of patients receiving radiation therapy for lung cancers the increase in the scattered dose should be incorporated in the shielding calculations for the secondary barriers.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henzen, D; Schmidhalter, D; Volken, W

    Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distributionmore » was then projected to a 9.5 × 5.9 × 3.9 m{sup 3} vault, generating an “intensity map” using a binning of 50 × 50 cm{sup 2}. The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zamora, D; Moirano, J; Kanal, K

    Purpose: A fundamental measure performed during an annual physics CT evaluation confirms that system displayed CTDIvol nearly matches the independently measured value in phantom. For wide-beam (z-direction) CT scanners, AAPM Report 111 defined an ideal measurement method; however, the method often lacks practicality. The purpose of this preliminary study is to develop a set of conversion factors for a wide-beam CT scanner, relating the CTDIvol measured with a conventional setup (single CTDI phantom) versus the AAPM Report 111 approach (three abutting CTDI phantoms). Methods: For both the body CTDI and head CTDI, two acquisition setups were used: A) conventional singlemore » phantom and B) triple phantom. Of primary concern were the larger nominal beam widths for which a standard CTDI phantom setup would not provide adequate scatter conditions. Nominal beam width (160 or 120 mm) and kVp (100, 120, 140) were modulated based on the underlying clinical protocol. Exposure measurements were taken using a CT pencil ion chamber in the center and 12 o’clock position, and CTDIvol was calculated with ‘nT’ limited to 100 mm. A conversion factor (CF) was calculated as the ratio of CTDIvol measured in setup B versus setup A. Results: For body CTDI, the CF ranged from 1.04 up to 1.10, indicating a 4–10% difference between usage of one and three phantoms. For a nominal beam width of 160 mm, the CF did vary with selected kVp. For head CTDI at nominal beam widths of 120 and 160 mm, the CF was 1.00 and 1.05, respectively, independent of the kVp used (100, 120, and 140). Conclusions: A clear understanding of the manufacturer method of estimating the displayed CTDIvol is important when interpreting annual test results, as the acquisition setup may lead to an error of up to 10%. With appropriately defined CF, single phantom use is feasible.« less

  15. Analysis of position-dependent Compton scatter in scintimammography with mild compression

    NASA Astrophysics Data System (ADS)

    Williams, M. B.; Narayanan, D.; More, M. J.; Goodale, P. J.; Majewski, S.; Kieper, D. A.

    2003-10-01

    In breast scintigraphy using /sup 99m/Tc-sestamibi the relatively low radiotracer uptake in the breast compared to that in other organs such as the heart results in a large fraction of the detected events being Compton scattered gamma-rays. In this study, our goal was to determine whether generalized conclusions regarding scatter-to-primary ratios at various locations within the breast image are possible, and if so, to use them to make explicit scatter corrections to the breast scintigrams. Energy spectra were obtained from patient scans for contiguous regions of interest (ROIs) centered left to right within the image of the breast, and extending from the chest wall edge of the image to the anterior edge. An anthropomorphic torso phantom with fillable internal organs and a compressed-shape breast containing water only was used to obtain realistic position-dependent scatter-only spectra. For each ROI, the measured patient energy spectrum was fitted with a linear combination of the scatter-only spectrum from the anthropomorphic phantom and the scatter-free spectrum from a point source. We found that although there is a very strong dependence on location within the breast of the scatter-to-primary ratio, the spectra are well modeled by a linear combination of position-dependent scatter-only spectra and a position-independent scatter-free spectrum, resulting in a set of position-dependent correction factors. These correction factors can be used along with measured emission spectra from a given breast to correct for the Compton scatter in the scintigrams. However, the large variation among patients in the magnitude of the position-dependent scatter makes the success of universal correction approaches unlikely.

  16. Epidemiological aspects of Pediculosis capitis and treatment evaluation in primary-school children in Iran.

    PubMed

    Motovali-Emami, Mohammad; Aflatoonian, Mohammad Reza; Fekri, Alireza; Yazdi, Mahbobeh

    2008-01-15

    This study was undertaken to assess the prevalence of and epidemiological factors associated with, head lice infections in Iranian primary schools in 2006 and evaluate data on the therapeutic efficacy of lindane shampoo. A total of 40586 children (19774 boys (48.72%) and 20812 girls (51.28%)] from 198 Governmentprimary schools in Kerman, were screened for head lice between March and June 2006. The diagnosis of head lice infestation was confirmed by clinical inspection of scalp and hair for the presence of adult lice nymphal stage, or eggs (nit) by line-toothed head lice comb. All children infested with lice were treated with lindane shampoo (1% gamma benzene hexachloride). The overall prevalence of head lice infestation was 1.8%. The prevalence of infestation was significantly higher in girls (2.9%) than in boys (0.6%) (p = 0.000). The infestation rate was greater among pupils who were living in rural areas (4.6%) than in urban areas (1.5%). Of the 721 children with a positive examination result, 424 pupils (58.8%) were reported as having been infested with head lice in the previous 6 months. Mother's education level was a significant risk factor in this model (p < 0.05). At 2 weeks after the primary treatment, the success rates of treatment were 49%. Comprehensive survey in our work showed the better future of the disease and related factors. Education campaigns by health care officials, physicians and teachers are expected to be helpful for head lice control. It is essential that governments should be supported form cooperation between the school authorities and public health centers to successful control head lice infestation in primary school. Also there is an urgent need to identify safe, novel insecticides for proved efficacy.

  17. Dose assessment for the fetus considering scattered and secondary radiation from photon and proton therapy when treating a brain tumor of the mother

    NASA Astrophysics Data System (ADS)

    Geng, Changran; Moteabbed, Maryam; Seco, Joao; Gao, Yiming; Xu, X. George; Ramos-Méndez, José; Faddegon, Bruce; Paganetti, Harald

    2016-01-01

    The goal of this work was to determine the scattered photon dose and secondary neutron dose and resulting risk for the sensitive fetus from photon and proton radiotherapy when treating a brain tumor during pregnancy. Anthropomorphic pregnancy phantoms with three stages (3-, 6-, 9-month) based on ICRP reference parameters were implemented in Monte Carlo platform TOPAS, to evaluate the scattered dose and secondary neutron dose and dose equivalent. To evaluate the dose equivalent, dose averaged quality factors were considered for neutrons. This study compared three treatment modalities: passive scattering and pencil beam scanning proton therapy (PPT and PBS) and 6-MV 3D conformal photon therapy. The results show that, for 3D conformal photon therapy, the scattered photon dose equivalent to the fetal body increases from 0.011 to 0.030 mSv per treatment Gy with increasing stage of gestation. For PBS, the neutron dose equivalent to the fetal body was significantly lower, i.e. increasing from 1.5  ×  10-3 to 2.5  ×  10-3 mSv per treatment Gy with increasing stage of gestation. For PPT, the neutron dose equivalent of the fetus decreases from 0.17 to 0.13 mSv per treatment Gy with the growing fetus. The ratios of dose equivalents to the fetus for a 52.2 Gy(RBE) course of radiation therapy to a typical CT scan of the mother’s head ranged from 3.4-4.4 for PBS, 30-41 for 3D conformal photon therapy and 180-500 for PPT, respectively. The attained dose to a fetus from the three modalities is far lower than the thresholds of malformation, severe mental retardation and lethal death. The childhood cancer excessive absolute risk was estimated using a linear no-threshold dose-response relationship. The risk would be 1.0 (95% CI: 0.6, 1.6) and 0.1 (95% CI:  -0.01, 0.52) in 105 for the 9-month fetus for PBS with a prescribed dose of 52.2 Gy(RBE). The increased risks for PPT and photon therapy are about two and one orders of magnitude larger than that for PBS, respectively. We can conclude that a pregnant woman with a brain tumor could be treated with pencil beam scanning with acceptable risks to the fetus.

  18. Two Heads Are Better than One: Influencing Preservice Classroom Teachers' Understanding and Practice of Classroom-Library Collaboration

    ERIC Educational Resources Information Center

    Moreillon, Judi

    2008-01-01

    Two Heads Are Better than One: The Factors Influencing the Understanding and Practice of Classroom-Library Collaboration proposed to identify the factors involved in educating future K-8 classroom teachers about collaboration for instruction with school library media specialists (SLMSs). This longitudinal study monitored the growth of teacher…

  19. The prevalence of food insecurity and associated factors among households with children in Head Start programs in Houston, Texas and Birmingham, Alabama

    USDA-ARS?s Scientific Manuscript database

    This study measured food security and hunger of households enrolled in Head Start in Houston, Texas, and Birmingham, Alabama and assessed factors that could affect food security. Interviewers collected data from primary caregivers on demographic characteristics, dietary intake, and the six-item US f...

  20. Factors that Impact West Virginia Head Start Parental Involvement in Early Literacy

    ERIC Educational Resources Information Center

    Clausell, Arlene Midget

    2010-01-01

    The research problem is: Many parents are not involved in their children's early literacy education. Some Head Start parents experience issues that keep them from teaching their children early literacy skills. The research questions were: What are the factors for parental involvement in the support of early literacy skill development for their…

  1. Linear attenuation coefficients of tissues from 1 keV to 150 keV

    NASA Astrophysics Data System (ADS)

    Böke, Aysun

    2014-09-01

    The linear attenuation coefficients and three interaction processes have been computed for liver, kidney, muscle, fat and for a range of x-ray energies from 1 keV to 150 keV. Molecular photoelectric absorption cross sections were calculated from atomic cross section data. Total coherent (Rayleigh) and incoherent (Compton) scattering cross sections were obtained by numerical integration over combinations of F2m(x) with the Thomson formula and Sm(x) with the Klein-Nishina formula, respectively. For the coherent (Rayleigh) scattering cross section calculations, molecular form factors were obtained from recent experimental data in the literature for values of x<1 Å-1 and from the relativistic modified atomic form factors for values of x≥1 Å-1. With the inclusion of molecular interference effects in the coherent (Rayleigh) scattering, more accurate knowledge of the scatter from these tissues will be provided. The number of elements involved in tissue composition is 5 for liver, 47 for kidney, 44 for muscle and 3 for fat. The results are compared with previously published experimental and theoretical linear attenuation coefficients. In general, good agreement is obtained. The molecular form factors and scattering functions and cross sections are incorporated into a Monte Carlo program. The energy distributions of x-ray photons scattered from tissues have been simulated and the results are presented.

  2. Theoretical model of x-ray scattering as a dense matter probe.

    PubMed

    Gregori, G; Glenzer, S H; Rozmus, W; Lee, R W; Landen, O L

    2003-02-01

    We present analytical expressions for the dynamic structure factor, or form factor S(k,omega), which is the quantity describing the x-ray cross section from a dense plasma or a simple liquid. Our results, based on the random phase approximation for the treatment on the charged particle coupling, can be applied to describe scattering from either weakly coupled classical plasmas or degenerate electron liquids. Our form factor correctly reproduces the Compton energy down-shift and the known Fermi-Dirac electron velocity distribution for S(k,omega) in the case of a cold degenerate plasma. The usual concept of scattering parameter is also reinterpreted for the degenerate case in order to include the effect of the Thomas-Fermi screening. The results shown in this work can be applied to interpreting x-ray scattering in warm dense plasmas occurring in inertial confinement fusion experiments or for the modeling of solid density matter found in the interior of planets.

  3. Comparing the quality of passively-scattered proton and photon tomotherapy plans for brain and head and neck disease sites.

    PubMed

    Kainz, Kristofer; Firat, Selim; Wilson, J Frank; Schultz, Christopher; Siker, Malika; Wang, Andrew; Olson, Dan; Li, X Allen

    2015-03-21

    We compare the quality of photon IMRT (helical tomotherapy) with classic proton plans for brain, head and neck tumors, in terms of target dose uniformity and conformity along with organ-at-risk (OAR) sparing. Plans were created for twelve target volumes among eight cases. All patients were originally planned and treated using helical tomotherapy. Proton plans were generated using a passively-scattered beam model with a maximum range of 32 g cm(-2) (225 MeV), range modulation in 0.5 g cm(-2) increments and range compensators with 4.8 mm milling tool diameters. All proton plans were limited to two to four beams. Plan quality was compared using uniformity index (UI), conformation number (CN) and a EUD-based plan quality index (fEUD). For 11 of the 12 targets, UI was improved for the proton plan; on average, UI was 1.05 for protons versus 1.08 for tomotherapy. For 7 of the 12 targets, the tomotherapy plan exhibited more favorable CN. For proximal OARs, the improved dose conformity to the target volume from tomotherapy led to a lower maximum dose. For distal OARs, the maximum dose was much lower for proton plans. For 6 of the 8 cases, near-total avoidance for distal OARs provided by protons leads to improved fEUD. However, if distal OARs are excluded in the fEUD calculation, the proton plans exhibit better fEUD in only 3 of the 8 cases. The distal OAR sparing and target dose uniformity are generally better with passive-scatter proton planning than with photon tomotherapy; proton therapy may be preferred if the clinician deems those attributes critical. However, tomotherapy may serve equally as well as protons for cases where superior target dose conformity from tomotherapy leads to plan quality nearly identical to or better than protons and for cases where distal OAR sparing is not concerning.

  4. SU-E-I-11: A New Cone-Beam CT System for Bedside Head Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, H; Zeng, W; Xu, P

    Purpose: To design and develop a new mobile cone-beam CT (CBCT) system for head imaging with good soft-tissue visibility, to be used bedside in ICU and neurosurgery department to monitor treatment and operation outcome in brain patients. Methods: The imaging chain consists of a 30cmx25cm amorphous silicon flat panel detector and a pulsed, stationary anode monoblock x-ray source of 100kVp at a maximal tube current of 10mA. The detector and source are supported on motorized mechanisms to provide detector lateral shift and source angular tilt, enabling a centered digital radiographic imaging mode and half-fan CBCT, while maximizing the use ofmore » the x-ray field and keep the source to detector distance short. A focused linear anti-scatter grid is mounted on the detector, and commercial software with scatter and other corrective algorithms is used for data processing and image reconstruction. The gantry rotates around a horizontal axis, and is able to adjust its height for different patient table positions. Cables are routed through a custom protective sleeve over a large bore with an in-plane twister band, facilitating single 360-degree rotation without a slip-ring at a speed up to 5 seconds per rotation. A UPS provides about 10 minutes of operation off the battery when unplugged. The gantry is on locked casters, whose brake is control by two push handles on both sides for easy reposition. The entire system is designed to have a light weight and a compact size for excellent maneuverability. Results: System design is complete and main imaging components are tested. Initial results will be presented and discussed later in the presentation. Conclusion: A new mobile CBCT system for head imaging is being developed. With its compact size, a large bore, and quality design, it is expected to be a useful imaging tool for bedside uses. The work is supported by a grant from Chinese Academy of Sciences.« less

  5. Anti-cancer Effect of Luminacin, a Marine Microbial Extract, in Head and Neck Squamous Cell Carcinoma Progression via Autophagic Cell Death.

    PubMed

    Shin, Yoo Seob; Cha, Hyun Young; Lee, Bok-Soon; Kang, Sung Un; Hwang, Hye Sook; Kwon, Hak Cheol; Kim, Chul-Ho; Choi, Eun Chang

    2016-04-01

    The purpose of this study is to determine whether luminacin, a marine microbial extract from the Streptomyces species, has anti-tumor effects on head and neck squamous cell carcinoma (HNSCC) cell lines via autophagic cell death. Inhibition of cell survival and increased cell death was measured using cell viability, colony forming, and apoptosis assays. Migration and invasion abilities of head and cancer cells were evaluated using wound healing, scattering, and invasion assays. Changes in the signal pathway related to autophagic cell death were investigated. Drug toxicity of luminacin was examined in in vitro HaCaT cells and an in vivo zebrafish model. Luminacin showed potent cytotoxicity in HNSCC cells in cell viability, colony forming, and fluorescence-activated cell sorting analysis. In vitro migration and invasion of HNSCC cells were attenuated by luminacin treatment. Combined with Beclin-1 and LC3B, Luminacin induced autophagic cell death in head and neck cancer cells. In addition, in a zebrafish model and human keratinocyte cell line used for toxicity testing, luminacin treatment with a cytotoxic concentration to HNSCC cells did not cause toxicity. Taken together, these results demonstrate that luminacin induces the inhibition of growth and cancer progression via autophagic cell death in HNSCC cell lines, indicating a possible alternative chemotherapeutic approach for treatment of HNSCC.

  6. Head Position Preference in the Human Newborn: A New Look.

    ERIC Educational Resources Information Center

    Ronnqvist, Louise; Hopkins, Brian

    1998-01-01

    Studied head position preference in 20 newborns differing by Cesarean or vaginal delivery and sex. Found that neither factor accounted for differences. The head turned right more often and was maintained longer in this position during quiet wakefulness, regardless of scoring method. When using global scoring, duration of midline position was…

  7. SU-E-T-275: Dose Build Up and Bolusing Characteristics for Total Body Irradiation Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butson, M; Pope, D; Whitaker, M

    2015-06-15

    Purpose: Total Body Irradiation (TBI) treatments are mainly used in a preparative regimen for haematopoietic stem cell (or bone marrow) transplantation. Our standard regimen is a 12 Gy / 6 fraction bi-daily technique. To evaluate the delivered dose homogeneity to the patient, EBT3 Gafchromic film is positioned at the head, neck, chest, pelvis and groin for all fractions. This work investigates and quantifies the build-up dose characteristics at TBI distances and requirements for in-vivo dosimetry bolusing. Methods: Percentage dose build up characteristics of photon beams have been investigated at large extended SSD’s using parallel plate ionisations chambers (Attix) and EBT3more » Gafchromic film. Measurements were made to open fields at different field sizes as well as large 40cm × 40cm fields with differing scatter conditions such as the introduction of standard Perspex scattering plates at different distances to the measurement point. Results: Percentage surface dose measured values for open fields at 300 cm SSD were found to range from 20 % up to 65.5 % for fields of 5 cm × 5 cm to 40 cm × 40 cm. With the introduction of 1cm Perspex scattering plates used in TBI treatments the surface dose values increased up to 83% to 90%, depending on the position of the Perspex scattering plate compared to the measurement point. Our work showed that at least 3mm water equivalent bolus / scatter material should be placed over the EBT3 for accurate dose assessment for TBI treatments. Conclusion: Build up dose characteristics exist at long (300cm) SSD’s including treatments using Perspex scattering plates placed at various distances form the patient during TBI treatment. Top accurately assess the applied dose during treatment, in-vivo dosimeters such as Gafchromic EBT3 should have at least 3mm bolus / scatter material placed over them to measure actual applied doses.« less

  8. GATE Simulations of Small Animal SPECT for Determination of Scatter Fraction as a Function of Object Size

    NASA Astrophysics Data System (ADS)

    Konik, Arda; Madsen, Mark T.; Sunderland, John J.

    2012-10-01

    In human emission tomography, combined PET/CT and SPECT/CT cameras provide accurate attenuation maps for sophisticated scatter and attenuation corrections. Having proven their potential, these scanners are being adapted for small animal imaging using similar correction approaches. However, attenuation and scatter effects in small animal imaging are substantially less than in human imaging. Hence, the value of sophisticated corrections is not obvious for small animal imaging considering the additional cost and complexity of these methods. In this study, using GATE Monte Carlo package, we simulated the Inveon small animal SPECT (single pinhole collimator) scanner to find the scatter fractions of various sizes of the NEMA-mouse (diameter: 2-5.5 cm , length: 7 cm), NEMA-rat (diameter: 3-5.5 cm, length: 15 cm) and MOBY (diameter: 2.1-5.5 cm, length: 3.5-9.1 cm) phantoms. The simulations were performed for three radionuclides commonly used in small animal SPECT studies:99mTc (140 keV), 111In (171 keV 90% and 245 keV 94%) and 125I (effective 27.5 keV). For the MOBY phantoms, the total Compton scatter fractions ranged (over the range of phantom sizes) from 4-10% for 99mTc (126-154 keV), 7-16% for 111In (154-188 keV), 3-7% for 111In (220-270 keV) and 17-30% for 125I (15-45 keV) including the scatter contributions from the tungsten collimator, lead shield and air (inside and outside the camera heads). For the NEMA-rat phantoms, the scatter fractions ranged from 10-15% (99mTc), 17-23% 111In: 154-188 keV), 8-12% (111In: 220-270 keV) and 32-40% (125I). Our results suggest that energy window methods based on solely emission data are sufficient for all mouse and most rat studies for 99mTc and 111In. However, more sophisticated methods may be needed for 125I.

  9. The influence of gravity on regional lung blood flow in humans: SPECT in the upright and head-down posture.

    PubMed

    Ax, M; Sanchez-Crespo, A; Lindahl, S G E; Mure, M; Petersson, J

    2017-06-01

    Previous studies in humans have shown that gravity has little influence on the distribution of lung blood flow while changing posture from supine to prone. This study aimed to evaluate the maximal influence of posture by comparison of regional lung blood flow in the upright and head-down posture in 8 healthy volunteers, using a tilt table. Regional lung blood flow was marked by intravenous injection of macroaggregates of human albumin labeled with 99m Tc or 113m In, in the upright and head-down posture, respectively, during tidal breathing. Both radiotracers remain fixed in the lung after administration. The distribution of radioactivity was mapped using quantitative single photon emission computed tomography (SPECT) corrected for attenuation and scatter. All images were obtained supine during tidal breathing. A shift from upright to the head-down posture caused a clear redistribution of blood flow from basal to apical regions. We conclude that posture plays a role for the distribution of lung blood flow in upright humans, and that the influence of posture, and thereby gravity, is much greater in the upright and head-down posture than in horizontal postures. However, the results of the study demonstrate that lung structure is the main determinant of regional blood flow and gravity is a secondary contributor to the distribution of lung blood flow in the upright and head-down positions. NEW & NOTEWORTHY Using a dual-isotope quantitative SPECT method, we demonstrated that although a shift in posture redistributes blood flow in the direction of gravity, the results are also consistent with lung structure being a greater determinant of regional blood flow than gravity. To our knowledge, this is the first study to use modern imaging methods to quantify the shift in regional lung blood flow in humans at a change between the upright and head-down postures. Copyright © 2017 the American Physiological Society.

  10. Leiomyosarcoma of the head and neck: A 17-year single institution experience and review of the National Cancer Data Base.

    PubMed

    Workman, Alan D; Farquhar, Douglas R; Brody, Robert M; Parasher, Arjun K; Carey, Ryan M; Purkey, Michael T; Nagda, Danish A; Brooks, John S; Hartner, Lee P; Brant, Jason A; Newman, Jason G

    2018-04-01

    Leiomyosarcoma is a rare neoplasm of the head and neck. The purpose of this study was to present our single-institution case series of head and neck leiomyosarcoma and a review of cases in the National Cancer Data Base (NCDB). Patients with head and neck leiomyosarcoma at the University of Pennsylvania and in the NCDB were identified. Demographic characteristics, tumor factors, treatment paradigms, and outcomes were evaluated for prognostic significance. Nine patients with head and neck leiomyosarcoma from the institution were identified; a majority had high-grade disease and cutaneous leiomyosarcoma, with a 5-year survival rate of 50%. Two hundred fifty-nine patients with leiomyosarcoma were found in the NCDB; macroscopic positive margins and high-grade disease were associated with poor prognosis (P < .01), and positive surgical margins were related to adjuvant radiation (P < .001). Head and neck leiomyosarcoma presents at a high grade and is preferentially treated with surgery. Several demographic and tumor-specific factors are associated with outcomes and prognosis. © 2017 Wiley Periodicals, Inc.

  11. Geometrically complex 3D-printed phantoms for diffuse optical imaging.

    PubMed

    Dempsey, Laura A; Persad, Melissa; Powell, Samuel; Chitnis, Danial; Hebden, Jeremy C

    2017-03-01

    Tissue-equivalent phantoms that mimic the optical properties of human and animal tissues are commonly used in diffuse optical imaging research to characterize instrumentation or evaluate an image reconstruction method. Although many recipes have been produced for generating solid phantoms with specified absorption and transport scattering coefficients at visible and near-infrared wavelengths, the construction methods are generally time-consuming and are unable to create complex geometries. We present a method of generating phantoms using a standard 3D printer. A simple recipe was devised which enables printed phantoms to be produced with precisely known optical properties. To illustrate the capability of the method, we describe the creation of an anatomically accurate, tissue-equivalent premature infant head optical phantom with a hollow brain space based on MRI atlas data. A diffuse optical image of the phantom is acquired when a high contrast target is inserted into the hollow space filled with an aqueous scattering solution.

  12. Geometrically complex 3D-printed phantoms for diffuse optical imaging

    PubMed Central

    Dempsey, Laura A.; Persad, Melissa; Powell, Samuel; Chitnis, Danial; Hebden, Jeremy C.

    2017-01-01

    Tissue-equivalent phantoms that mimic the optical properties of human and animal tissues are commonly used in diffuse optical imaging research to characterize instrumentation or evaluate an image reconstruction method. Although many recipes have been produced for generating solid phantoms with specified absorption and transport scattering coefficients at visible and near-infrared wavelengths, the construction methods are generally time-consuming and are unable to create complex geometries. We present a method of generating phantoms using a standard 3D printer. A simple recipe was devised which enables printed phantoms to be produced with precisely known optical properties. To illustrate the capability of the method, we describe the creation of an anatomically accurate, tissue-equivalent premature infant head optical phantom with a hollow brain space based on MRI atlas data. A diffuse optical image of the phantom is acquired when a high contrast target is inserted into the hollow space filled with an aqueous scattering solution. PMID:28663863

  13. Collision dynamics of H+ + N2 at low energies based on time-dependent density-functional theory

    NASA Astrophysics Data System (ADS)

    Yu, W.; Zhang, Y.; Zhang, F. S.; Hutton, R.; Zou, Y.; Gao, C.-Z.; Wei, B.

    2018-02-01

    Using time-dependent density-functional theory at the level of local density approximation augmented by a self-interaction correction and coupled non-adiabatically to molecular dynamics, we study, from a theoretical perspective, scattering dynamics of the proton in collisions with the N2 molecule at 30 eV. Nine different collision configurations are employed to analyze the proton energy loss spectra, electron depletion, scattering angles and self-interaction effects. Our results agree qualitatively with the experimental data and previous theoretical calculations. The discrepancies are ascribed to the limitation of the theoretical models in use. We find that self-interaction effects can significantly influence the electron capture and the excited diatomic vibrational motion, which is in consistent with other calculations. In addition, it is found that the molecular structure can be readily retrieved from the proton energy loss spectra due to a significant momentum transfer in head-on collisions.

  14. A description of the catalog division project at the College of Physicians of Philadelphia Library.

    PubMed Central

    Caspari, S B; Batty, E L

    1975-01-01

    This paper describes the procedures used at the Library of the College of Physicians of Philadelphia to divide its ninety-year-old dictionary card catalog. The division was necessitated by overcrowding, obsolete subject headings, and lack of a complete authority list which resulted in like materials being scattered throughout the catalog under several headings. Two catalogs were created: the historical-biographical catalog, representing all works published before 1950 and all works of historical or biographical nature; and the current catalog, containing all works published from 1950 on, excepting historical or biographical materials. The 1950- catalog was further divided into name and subject catalogs, and the subject section was revised according to MeSH. The project was completed in about two years. As a result, searching time has been much reduced, and the library is able to take advantage of the annual revisions of MeSH to update the subject catalog. PMID:1173786

  15. Local polar fluctuations in lead halide perovskite crystals

    DOE PAGES

    Yaffe, Omer; Guo, Yinsheng; Tan, Liang Z.; ...

    2017-03-28

    Hybrid lead-halide perovskites have emerged as an excellent class of photovoltaic materials. Recent reports suggest that the organic molecular cation is responsible for local polar fluctuations that inhibit carrier recombination. We combine low-frequency Raman scattering with first-principles molecular dynamics (MD) to study the fundamental nature of these local polar fluctuations. Our observations of a strong central peak in the cubic phase of both hybrid (CH 3NH 3PbBr 3) and all-inorganic (CsPbBr 3) lead-halide perovskites show that anharmonic, local polar fluctuations are intrinsic to the general lead-halide perovskite structure, and not unique to the dipolar organic cation. Furthermore, MD simulations indicatemore » that head-to-head Cs motion coupled to Br face expansion, occurring on a few hundred femtosecond time scale, drives the local polar fluctuations in CsPbBr 3.« less

  16. The effect of intact talin and talin tail fragment on actin filament dynamics and structure depends on pH and ionic strength.

    PubMed

    Goldmann, W H; Hess, D; Isenberg, G

    1999-03-01

    We employed quasi-elastic light scattering and electron microscopy to investigate the influence of intact talin and talin tail fragment on actin filament dynamics and network structure. Using these methods, we confirm previous reports that intact talin induces cross-linking as well as filament shortening on actin networks. We now show that the effect of intact talin as well as talin tail fragment on actin networks is controlled by pH and ionic strength. At pH 7.5, actin filament dynamics in the presence of intact talin and talin tail fragment are characterized by a rapid decay of the dynamic structure factor and by a square root power law for the stretched exponential decay which is in contrast with the theory for pure actin solutions. At pH 6 and low ionic strength, intact talin cross-links actin filaments more tightly than talin tail fragment. Talin head fragment showed no effect on actin networks, indicating that the actin binding sites reside probably exclusively within the tail domain.

  17. Poster — Thur Eve — 47: Monte Carlo Simulation of Scp, Sc and Sp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhan, Lixin; Jiang, Runqing; Osei, Ernest K.

    The in-water output ratio (Scp), in-air output ratio (Sc), and phantom scattering factor (Sp) are important parameters for radiotherapy dose calculation. Experimentally, Scp is obtained by measuring the dose rate ratio in water phantom, and Sc the water Kerma rate ratio in air. There is no method that allows direct measurement of Sp. Monte Carlo (MC) method has been used to simulate Scp and Sc in literatures, similar to experimental setup, but no MC direct simulation of Sp available yet to the best of our knowledge. We propose in this report a method of performing direct MC simulation of Sp.more » Starting from the definition, we derived that Sp of a clinical photon beam can be approximated by the ratio of the dose rates contributed from the primary beam for a given field size to the reference field size. Since only the primary beam is used, any Linac head scattering should be excluded from the simulation, which can be realized by using the incident electron as a scoring parameter for MU. We performed MC simulations for Scp, Sc and Sp. Scp matches well with golden beam data. Sp obtained by the proposed method agrees well with what is obtained using the traditional method, Sp=Scp/Sc. Since the smaller the field size, the more the primary beam dominates, our Sp simulation method is accurate for small field. By analyzing the calculated data, we found that this method can be used with no problem for large fields. The difference it introduced is clinically insignificant.« less

  18. Enhancement factor in low-coherence enhanced backscattering and its applications for characterizing experimental skin carcinogenesis

    NASA Astrophysics Data System (ADS)

    Liu, Jingjing; Xu, Zhengbin; Song, Qinghai; Konger, Raymond L.; Kim, Young L.

    2010-05-01

    We experimentally study potential mechanisms by which the enhancement factor in low-coherence enhanced backscattering (LEBS) can probe subtle variations in radial intensity distribution in weakly scattering media. We use enhanced backscattering of light by implementing either (1) low spatial coherence illumination or (2) multiple spatially independent detections using a microlens array under spatially coherent illumination. We show that the enhancement factor in these configurations is a measure of the integrated intensity within the localized coherence or detection area, which can exhibit strong dependence on small perturbations in scattering properties. To further evaluate the utility of the LEBS enhancement factor, we use a well-established animal model of cutaneous two-stage chemical carcinogenesis. In this pilot study, we demonstrate that the LEBS enhancement factor can be substantially altered at a stage of preneoplasia. Our animal result supports the idea that early carcinogenesis can cause subtle alterations in the scattering properties that can be captured by the LEBS enhancement factor. Thus, the LEBS enhancement factor has the potential as an easily measurable biomarker in skin carcinogenesis.

  19. Air Mass Factor Formulation for Spectroscopic Measurements from Satellites: Application to Formaldehyde Retrievals from the Global Ozone Monitoring Experiment

    NASA Technical Reports Server (NTRS)

    Palmer, Paul I.; Jacob, Daniel J.; Chance, Kelly; Martin, Randall V.; Spurr, Robert J. D.; Kurosu, Thomas P.; Bey, Isabelle; Yantosca, Robert; Fiore, Arlene; Li, Qinbin

    2004-01-01

    We present a new formulation for the air mass factor (AMF) to convert slant column measurements of optically thin atmospheric species from space into total vertical columns. Because of atmospheric scattering, the AMF depends on the vertical distribution of the species. We formulate the AMF as the integral of the relative vertical distribution (shape factor) of the species over the depth of the atmosphere, weighted by altitude-dependent coefficients (scattering weights) computed independently from a radiative transfer model. The scattering weights are readily tabulated, and one can then obtain the AMF for any observation scene by using shape factors from a three dimensional (3-D) atmospheric chemistry model for the period of observation. This approach subsequently allows objective evaluation of the 3-D model with the observed vertical columns, since the shape factor and the vertical column in the model represent two independent pieces of information. We demonstrate the AMF method by using slant column measurements of formaldehyde at 346 nm from the Global Ozone Monitoring Experiment satellite instrument over North America during July 1996. Shape factors are cumputed with the Global Earth Observing System CHEMistry (GEOS-CHEM) global 3-D model and are checked for consistency with the few available aircraft measurements. Scattering weights increase by an order of magnitude from the surface to the upper troposphere. The AMFs are typically 20-40% less over continents than over the oceans and are approximately half the values calculated in the absence of scattering. Model-induced errors in the AMF are estimated to be approximately 10%. The GEOS-CHEM model captures 50% and 60% of the variances in the observed slant and vertical columns, respectively. Comparison of the simulated and observed vertical columns allows assessment of model bias.

  20. Active head rotations and eye-head coordination

    NASA Technical Reports Server (NTRS)

    Zangemeister, W. H.; Stark, L.

    1981-01-01

    It is pointed out that head movements play an important role in gaze. The interaction between eye and head movements involves both their shared role in directing gaze and the compensatory vestibular ocular reflex. The dynamics of head trajectories are discussed, taking into account the use of parameterization to obtain the peak velocity, peak accelerations, the times of these extrema, and the duration of the movement. Attention is given to the main sequence, neck muscle EMG and details of the head-movement trajectory, types of head model accelerations, the latency of eye and head movement in coordinated gaze, gaze latency as a function of various factors, and coordinated gaze types. Clinical examples of gaze-plane analysis are considered along with the instantaneous change of compensatory eye movement (CEM) gain, and aspects of variability.

  1. Influence of gravity on the orientation of vestibular induced quick phases.

    PubMed

    Pettorossi, V E; Errico, P; Ferraresi, A; Draicchio, F

    1995-01-01

    In rabbits and cats the orientation of the quick phases (QPs) of the vestibulo-ocular reflex (VOR) was studied varying the head position in space. At different head tilt positions, QPs induced by step vestibular stimulation disaligned with respect to the stimulus toward the orientation of the earth's horizontal axis. The rabbits' QPs were horizontal during yaw stimulation and remained horizontal in a range of head pitch of +/- 90 degrees (reorientation gain = 1). Therefore, the slow compensatory responses (CSPs) progressively disaligned compared with the QPs. QPs induced by roll stimulation also showed horizontal orientation, although these were rare in the upright position and occurred more frequently when the head was pitched. In cats only the yaw-induced QPs were coplanar with the stimulus, while QPs induced by pitching were mostly oblique. It followed that in either yawing or pitching, the QPs had their end point scattered within a horizontally elongated area of the visual field. When tilting cats in the frontal plane, the orientation of QP trajectories changed with respect to the stimulus so that the end point distribution tended to remain aligned toward the horizontal instead of being fixed in the orbit. The reorientation gain decreased from 1 to 0.5 by increasing the head tilt. On the basis of difference regarding eye implantation and motility it was suggested that the effect of gravity on the orientation of QPs could be aimed at maintaining the interocular axis aligned with the horizon in the rabbit and at orientating the visual scanning system in the horizontal plane in the cat.

  2. Man-in-the-loop study of filtering in airborne head tracking tasks

    NASA Technical Reports Server (NTRS)

    Lifshitz, S.; Merhav, S. J.

    1992-01-01

    A human-factors study is conducted of problems due to vibrations during the use of a helmet-mounted display (HMD) in tracking tasks whose major factors are target motion and head vibration. A method is proposed for improving aiming accuracy in such tracking tasks on the basis of (1) head-motion measurement and (2) the shifting of the reticle in the HMD in ways that inhibit much of the involuntary apparent motion of the reticle, relative to the target, and the nonvoluntary motion of the teleoperated device. The HMD inherently furnishes the visual feedback required by this scheme.

  3. Increased Phonon Scattering by Nanograins and Point Defects in Nanostructured Silicon with a Low Concentration of Germanium

    NASA Astrophysics Data System (ADS)

    Zhu, G. H.; Lee, H.; Lan, Y. C.; Wang, X. W.; Joshi, G.; Wang, D. Z.; Yang, J.; Vashaee, D.; Guilbert, H.; Pillitteri, A.; Dresselhaus, M. S.; Chen, G.; Ren, Z. F.

    2009-05-01

    The mechanism for phonon scattering by nanostructures and by point defects in nanostructured silicon (Si) and the silicon germanium (Ge) alloy and their thermoelectric properties are investigated. We found that the thermal conductivity is reduced by a factor of 10 in nanostructured Si in comparison with bulk crystalline Si. However, nanosize interfaces are not as effective as point defects in scattering phonons with wavelengths shorter than 1 nm. We further found that a 5at.% Ge replacing Si is very efficient in scattering phonons shorter than 1 nm, resulting in a further thermal conductivity reduction by a factor of 2, thereby leading to a thermoelectric figure of merit 0.95 for Si95Ge5, similar to that of large grained Si80Ge20 alloys.

  4. A homolog of Drosophila grainy head is essential for epidermal integrity in mice.

    PubMed

    Ting, Stephen B; Caddy, Jacinta; Hislop, Nikki; Wilanowski, Tomasz; Auden, Alana; Zhao, Lin-Lin; Ellis, Sarah; Kaur, Pritinder; Uchida, Yoshikazu; Holleran, Walter M; Elias, Peter M; Cunningham, John M; Jane, Stephen M

    2005-04-15

    The Drosophila cuticle is essential for maintaining the surface barrier defenses of the fly. Integral to cuticle resilience is the transcription factor grainy head, which regulates production of the enzyme required for covalent cross-linking of the cuticular structural components. We report that formation and maintenance of the epidermal barrier in mice are dependent on a mammalian homolog of grainy head, Grainy head-like 3. Mice lacking this factor display defective skin barrier function and deficient wound repair, accompanied by reduced expression of transglutaminase 1, the key enzyme involved in cross-linking the structural components of the superficial epidermis. These findings suggest that the functional mechanisms involving protein cross-linking that maintain the epidermal barrier and induce tissue repair are conserved across 700 million years of evolution.

  5. Improved scatterer property estimates from ultrasound backscatter for small gate lengths using a gate-edge correction factor

    NASA Astrophysics Data System (ADS)

    Oelze, Michael L.; O'Brien, William D.

    2004-11-01

    Backscattered rf signals used to construct conventional ultrasound B-mode images contain frequency-dependent information that can be examined through the backscattered power spectrum. The backscattered power spectrum is found by taking the magnitude squared of the Fourier transform of a gated time segment corresponding to a region in the scattering volume. When a time segment is gated, the edges of the gated regions change the frequency content of the backscattered power spectrum due to truncating of the waveform. Tapered windows, like the Hanning window, and longer gate lengths reduce the relative contribution of the gate-edge effects. A new gate-edge correction factor was developed that partially accounted for the edge effects. The gate-edge correction factor gave more accurate estimates of scatterer properties at small gate lengths compared to conventional windowing functions. The gate-edge correction factor gave estimates of scatterer properties within 5% of actual values at very small gate lengths (less than 5 spatial pulse lengths) in both simulations and from measurements on glass-bead phantoms. While the gate-edge correction factor gave higher accuracy of estimates at smaller gate lengths, the precision of estimates was not improved at small gate lengths over conventional windowing functions. .

  6. Head Trauma in Mixed Martial Arts.

    PubMed

    Hutchison, Michael G; Lawrence, David W; Cusimano, Michael D; Schweizer, Tom A

    2014-06-01

    Mixed martial arts (MMA) is a full combative sport with a recent global increase in popularity despite significant scrutiny from medical associations. To date, the empirical research of the risk of head injuries associated with this sport is limited. Youth and amateur participation is growing, warranting investigation into the burden and mechanism of injuries associated with this sport. (1) To determine the incidence, risk factors, and characteristics of knockouts (KOs) and technical knockouts (TKOs) from repetitive strikes in professional MMA; and (2) to identify the mechanisms of head trauma and the situational factors that lead to KOs and TKOs secondary to repetitive strikes through video analysis. Descriptive epidemiology study. Competition data and video records for all KOs and TKOs from numbered Ultimate Fighting Championship MMA events (n = 844) between 2006 to 2012. Analyses included (1) multivariate logistic regression to investigate factors associated with an increased risk of sustaining a KO or TKO secondary to repetitive strikes and (2) video analysis of all KOs and TKOs secondary to repetitive strikes with descriptive statistics. During the study period, the KO rate was 6.4 per 100 athlete-exposures (AEs) (12.7% of matches), and the rate of TKOs secondary to repetitive strikes was 9.5 per 100 AEs (19.1% of matches), for a combined incidence of match-ending head trauma of 15.9 per 100 AEs (31.9% of matches). Logistic regression identified that weight class, earlier time in a round, earlier round in a match, and older age were risk factors for both KOs and TKOs secondary to repetitive strikes. Match significance and previously sustained KOs or TKOs were also risk factors for KOs. Video analysis identified that all KOs were the result of direct impact to the head, most frequently a strike to the mandibular region (53.9%). The average time between the KO-strike and match stoppage was 3.5 seconds (range, 0-20 seconds), with losers sustaining an average of 2.6 additional strikes (range, 0-20 strikes) to the head. For TKOs secondary to strikes, in the 30-second interval immediately preceding match stoppage, losers sustained, on average, 18.5 strikes (range, 5-46 strikes), with 92.3% of these being strikes to the head. Rates of KOs and TKOs in MMA are higher than previously reported rates in other combative and contact sports. Public health authorities and physicians should be cognizant of the rates and mechanisms of head trauma. Preventive measures to lessen the risks of head trauma for those who elect to participate in MMA are described. © 2014 The Author(s).

  7. Snow particles extracted from X-ray computed microtomography imagery and their single-scattering properties

    NASA Astrophysics Data System (ADS)

    Ishimoto, Hiroshi; Adachi, Satoru; Yamaguchi, Satoru; Tanikawa, Tomonori; Aoki, Teruo; Masuda, Kazuhiko

    2018-04-01

    Sizes and shapes of snow particles were determined from X-ray computed microtomography (micro-CT) images, and their single-scattering properties were calculated at visible and near-infrared wavelengths using a Geometrical Optics Method (GOM). We analyzed seven snow samples including fresh and aged artificial snow and natural snow obtained from field samples. Individual snow particles were numerically extracted, and the shape of each snow particle was defined by applying a rendering method. The size distribution and specific surface area distribution were estimated from the geometrical properties of the snow particles, and an effective particle radius was derived for each snow sample. The GOM calculations at wavelengths of 0.532 and 1.242 μm revealed that the realistic snow particles had similar scattering phase functions as those of previously modeled irregular shaped particles. Furthermore, distinct dendritic particles had a characteristic scattering phase function and asymmetry factor. The single-scattering properties of particles of effective radius reff were compared with the size-averaged single-scattering properties. We found that the particles of reff could be used as representative particles for calculating the average single-scattering properties of the snow. Furthermore, the single-scattering properties of the micro-CT particles were compared to those of particle shape models using our current snow retrieval algorithm. For the single-scattering phase function, the results of the micro-CT particles were consistent with those of a conceptual two-shape model. However, the particle size dependence differed for the single-scattering albedo and asymmetry factor.

  8. Computing the scatter component of mammographic images.

    PubMed

    Highnam, R P; Brady, J M; Shepstone, B J

    1994-01-01

    The authors build upon a technical report (Tech. Report OUEL 2009/93, Engng. Sci., Oxford Uni., Oxford, UK, 1993) in which they proposed a model of the mammographic imaging process for which scattered radiation is a key degrading factor. Here, the authors propose a way of estimating the scatter component of the signal at any pixel within a mammographic image, and they use this estimate for model-based image enhancement. The first step is to extend the authors' previous model to divide breast tissue into "interesting" (fibrous/glandular/cancerous) tissue and fat. The scatter model is then based on the idea that the amount of scattered radiation reaching a point is related to the energy imparted to the surrounding neighbourhood. This complex relationship is approximated using published empirical data, and it varies with the size of the breast being imaged. The approximation is further complicated by needing to take account of extra-focal radiation and breast edge effects. The approximation takes the form of a weighting mask which is convolved with the total signal (primary and scatter) to give a value which is input to a "scatter function", approximated using three reference cases, and which returns a scatter estimate. Given a scatter estimate, the more important primary component can be calculated and used to create an image recognizable by a radiologist. The images resulting from this process are clearly enhanced, and model verification tests based on an estimate of the thickness of interesting tissue present proved to be very successful. A good scatter model opens the was for further processing to remove the effects of other degrading factors, such as beam hardening.

  9. Prevalence of and factors associated with head impact during falls in older adults in long-term care.

    PubMed

    Schonnop, Rebecca; Yang, Yijian; Feldman, Fabio; Robinson, Erin; Loughin, Marie; Robinovitch, Stephen N

    2013-11-19

    Falls cause more than 60% of head injuries in older adults. Lack of objective evidence on the circumstances of these events is a barrier to prevention. We analyzed video footage to determine the frequency of and risk factors for head impact during falls in older adults in 2 long-term care facilities. Over 39 months, we captured on video 227 falls involving 133 residents. We used a validated questionnaire to analyze the mechanisms of each fall. We then examined whether the probability for head impact was associated with upper-limb protective responses (hand impact) and fall direction. Head impact occurred in 37% of falls, usually onto a vinyl or linoleum floor. Hand impact occurred in 74% of falls but had no significant effect on the probability of head impact (p = 0.3). An increased probability of head impact was associated with a forward initial fall direction, compared with backward falls (odds ratio [OR] 2.7, 95% confidence interval [CI] 1.3-5.9) or sideways falls (OR 2.8, 95% CI 1.2-6.3). In 36% of sideways falls, residents rotated to land backwards, which reduced the probability of head impact (OR 0.2, 95% CI 0.04-0.8). Head impact was common in observed falls in older adults living in long-term care facilities, particularly in forward falls. Backward rotation during descent appeared to be protective, but hand impact was not. Attention to upper-limb strength and teaching rotational falling techniques (as in martial arts training) may reduce fall-related head injuries in older adults.

  10. Factor structure of the pictorial scale of perceived competence and social acceptance with two pre-elementary samples.

    PubMed

    Mantzicopoulos, Panayota; French, Brian F; Maller, Susan J

    2004-01-01

    Competing models of the factorial structure of the Pictorial Scale of Perceived Competence and Social Acceptance (PSPCSA) were tested for fit using multisample confirmatory factor analysis. The best fitting model was tested for invariance (a) across samples of middle-class (n = 251) and economically disadvantaged (Head Start, n = 117) kindergarten children (whose ages ranged from 67 to 86 months), and (b) over time (at the end of preschool and kindergarten) for the Head Start sample. For kindergarten children, regardless of socioeconomic status, the factor structure of the PSPCSA was consistent with the 2-factor model of Competence and Acceptance. This model also fit reasonably well for Head Start children at the end of their preschool year. However, in addition to providing broad support for the dimensionality of the measure, our findings highlight important concerns about the PSPCSA. Copyright 2004 Society for Research in Child Development, Inc.

  11. The single scattering properties of the aerosol particles as aggregated spheres

    NASA Astrophysics Data System (ADS)

    Wu, Y.; Gu, X.; Cheng, T.; Xie, D.; Yu, T.; Chen, H.; Guo, J.

    2012-08-01

    The light scattering and absorption properties of anthropogenic aerosol particles such as soot aggregates are complicated in the temporal and spatial distribution, which introduce uncertainty of radiative forcing on global climate change. In order to study the single scattering properties of anthorpogenic aerosol particles, the structures of these aerosols such as soot paticles and soot-containing mixtures with the sulfate or organic matter, are simulated using the parallel diffusion limited aggregation algorithm (DLA) based on the transmission electron microscope images (TEM). Then, the single scattering properties of randomly oriented aerosols, such as scattering matrix, single scattering albedo (SSA), and asymmetry parameter (AP), are computed using the superposition T-matrix method. The comparisons of the single scattering properties of these specific types of clusters with different morphological and chemical factors such as fractal parameters, aspect ratio, monomer radius, mixture mode and refractive index, indicate that these different impact factors can respectively generate the significant influences on the single scattering properties of these aerosols. The results show that aspect ratio of circumscribed shape has relatively small effect on single scattering properties, for both differences of SSA and AP are less than 0.1. However, mixture modes of soot clusters with larger sulfate particles have remarkably important effects on the scattering and absorption properties of aggregated spheres, and SSA of those soot-containing mixtures are increased in proportion to the ratio of larger weakly absorbing attachments. Therefore, these complex aerosols come from man made pollution cannot be neglected in the aerosol retrievals. The study of the single scattering properties on these kinds of aggregated spheres is important and helpful in remote sensing observations and atmospheric radiation balance computations.

  12. Added aluminum shielding to attenuate back scatter electrons from intra-oral lead shields.

    PubMed

    Weidlich, G A; Nuesch, C E; Fuery, J J

    1996-01-01

    An intra-oral lead shield was developed that consists of a lead base with an aluminum layer that is placed upstream of the lead base. Several such shields with various thicknesses of Al layers were manufactured and quantitatively evaluated in 6 MeV and 12 MeV electron radiation by Thermoluminescent dosimetry (TLD) measurements. The clinical relevance was established by using a 5 cm backscatter block down-stream of the lead shield to simulate anatomical structures of the head and a 0.5 cm superflab bolus upstream of the Al layers of the shield to simulate the patient's lip or cheek. The TLDs were placed between the Al layers of the shield and the superflab to determine the intra-oral skin dose. TLD exposure results revealed that 59.8% of the skin dose at 6 MeV and 45.1% of the skin dose at 12 MeV is due to backscattered electrons. Introduction of a 3.0 mm thick Al layer reduces the backscatter contribution to 13.5% of the back scatter dose at 6 MeV and 56.3% of the back scatter dose at 12 MeV electron radiation.

  13. Study the efficacy of neuroprotective drugs on brain physiological properties during focal head injury using optical spectroscopy data analysis

    NASA Astrophysics Data System (ADS)

    Abookasis, David; Shochat, Ariel

    2016-03-01

    We present a comparative evaluation of five different neuroprotective drugs in the early phase following focal traumatic brain injury (TBI) in mouse intact head. The effectiveness of these drugs in terms of changes in brain tissue morphology and hemodynamic properties was experimentally evaluated through analysis of the optical absorption coefficient and spectral reduced scattering parameters in the range of 650-1000 nm. Anesthetized male mice (n=50 and n=10 control) were subjected to weight drop model mimics real life focal head trauma. Monitoring the effect of injury and neuroprotective drugs was obtained by using a diffuse reflectance spectroscopy system utilizing independent source-detector separation and location. Result indicates that administration of minocycline improve hemodynamic and reduced the level of tissue injury at an early phase post-injury while hypertonic saline treatment decrease brain water content. These findings highlight the heterogeneity between neuroprotective drugs and the ongoing controversy among researchers regarding which drug therapy is preferred for treatment of TBI. On the other hand, our results show the capability of optical spectroscopy technique to noninvasively study brain function following injury and drug therapy.

  14. Deep Tissue Fluorescent Imaging in Scattering Specimens Using Confocal Microscopy

    PubMed Central

    Clendenon, Sherry G.; Young, Pamela A.; Ferkowicz, Michael; Phillips, Carrie; Dunn, Kenneth W.

    2015-01-01

    In scattering specimens, multiphoton excitation and nondescanned detection improve imaging depth by a factor of 2 or more over confocal microscopy; however, imaging depth is still limited by scattering. We applied the concept of clearing to deep tissue imaging of highly scattering specimens. Clearing is a remarkably effective approach to improving image quality at depth using either confocal or multiphoton microscopy. Tissue clearing appears to eliminate the need for multiphoton excitation for deep tissue imaging. PMID:21729357

  15. A novel sampling method for multiple multiscale targets from scattering amplitudes at a fixed frequency

    NASA Astrophysics Data System (ADS)

    Liu, Xiaodong

    2017-08-01

    A sampling method by using scattering amplitude is proposed for shape and location reconstruction in inverse acoustic scattering problems. Only matrix multiplication is involved in the computation, thus the novel sampling method is very easy and simple to implement. With the help of the factorization of the far field operator, we establish an inf-criterion for characterization of underlying scatterers. This result is then used to give a lower bound of the proposed indicator functional for sampling points inside the scatterers. While for the sampling points outside the scatterers, we show that the indicator functional decays like the bessel functions as the sampling point goes away from the boundary of the scatterers. We also show that the proposed indicator functional continuously depends on the scattering amplitude, this further implies that the novel sampling method is extremely stable with respect to errors in the data. Different to the classical sampling method such as the linear sampling method or the factorization method, from the numerical point of view, the novel indicator takes its maximum near the boundary of the underlying target and decays like the bessel functions as the sampling points go away from the boundary. The numerical simulations also show that the proposed sampling method can deal with multiple multiscale case, even the different components are close to each other.

  16. Thomson scattering from a three-component plasma.

    PubMed

    Johnson, W R; Nilsen, J

    2014-02-01

    A model for a three-component plasma consisting of two distinct ionic species and electrons is developed and applied to study x-ray Thomson scattering. Ions of a specific type are assumed to be identical and are treated in the average-atom approximation. Given the plasma temperature and density, the model predicts mass densities, effective ionic charges, and cell volumes for each ionic type, together with the plasma chemical potential and free-electron density. Additionally, the average-atom treatment of individual ions provides a quantum-mechanical description of bound and continuum electrons. The model is used to obtain parameters needed to determine the dynamic structure factors for x-ray Thomson scattering from a three-component plasma. The contribution from inelastic scattering by free electrons is evaluated in the random-phase approximation. The contribution from inelastic scattering by bound electrons is evaluated using the bound-state and scattering wave functions obtained from the average-atom calculations. Finally, the partial static structure factors for elastic scattering by ions are evaluated using a two-component version of the Ornstein-Zernike equations with hypernetted chain closure, in which electron-ion interactions are accounted for using screened ion-ion interaction potentials. The model is used to predict the x-ray Thomson scattering spectrum from a CH plasma and the resulting spectrum is compared with experimental results obtained by Feltcher et al. [Phys. Plasmas 20, 056316 (2013)].

  17. Diaphragm correction factors for the FAC-IR-300 free-air ionization chamber.

    PubMed

    Mohammadi, Seyed Mostafa; Tavakoli-Anbaran, Hossein

    2018-02-01

    A free-air ionization chamber FAC-IR-300, designed by the Atomic Energy Organization of Iran, is used as the primary Iranian national standard for the photon air kerma. For accurate air kerma measurements, the contribution from the scattered photons to the total energy released in the collecting volume must be eliminated. One of the sources of scattered photons is the chamber's diaphragm. In this paper, the diaphragm scattering correction factor, k dia , and the diaphragm transmission correction factor, k tr , were introduced. These factors represent corrections to the measured charge (or current) for the photons scattered from the diaphragm surface and the photons penetrated through the diaphragm volume, respectively. The k dia and k tr values were estimated by Monte Carlo simulations. The simulations were performed for the mono-energetic photons in the energy range of 20 - 300keV. According to the simulation results, in this energy range, the k dia values vary between 0.9997 and 0.9948, and k tr values decrease from 1.0000 to 0.9965. The corrections grow in significance with increasing energy of the primary photons. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Assessment of Factors Resulting in Abuse Evaluations in Young Children with Minor Head Trauma

    ERIC Educational Resources Information Center

    Anderst, James D.

    2008-01-01

    Objective: The primary objective was to determine which of the examined factors prompted physicians to initiate a further abuse evaluation in young children with minor head injury. The recording of important historical elements in the charts of these patients was also evaluated. Methods: Charts of 349 children less than 3 years of age with minor…

  19. Family Risks and Protective Factors: Pathways to Early Head Start Toddlers' Social-Emotional Functioning

    ERIC Educational Resources Information Center

    Vick Whittaker, Jessica E.; Harden, Brenda Jones; See, Heather M.; Meisch, Allison D.; Westbrook, T'Pring R.

    2011-01-01

    Early Head Start children may be more likely to exhibit difficulties with social-emotional functioning due to the high-risk environments in which they live. However, positive parenting may serve as a protective factor against the influence of risk on children's outcomes. The current study examines the effects of contextual and proximal risks on…

  20. Examining Risk and Protective Factors in Head Start Populations Located in High- and Low-Violence Communities

    ERIC Educational Resources Information Center

    Fedor, Megan C.; Bender, Stacy L.; Carlson, John S.

    2010-01-01

    This study examined parental reports of children attending Head Start programs in high- (N = 200) and low- (N = 188) violence communities to determine whether differences existed in the level of risk and protective factors as measured by the Devereux Early Childhood Assessment (P. A. LeBuffe & J. A. Naglieri, 1999). Previous research has indicated…

  1. Stem cell-dependent formation of a functional anterior regeneration pole in planarians requires Zic and Forkhead transcription factors.

    PubMed

    Vogg, Matthias C; Owlarn, Suthira; Pérez Rico, Yuvia A; Xie, Jianlei; Suzuki, Yoko; Gentile, Luca; Wu, Wei; Bartscherer, Kerstin

    2014-06-15

    Planarians can regenerate their head within days. This process depends on the direction of adult stem cells to wound sites and the orchestration of their progenitors to commit to appropriate lineages and to arrange into patterned tissues. We identified a zinc finger transcription factor, Smed-ZicA, as a downstream target of Smed-FoxD, a Forkhead transcription factor required for head regeneration. Smed-zicA and Smed-FoxD are co-expressed with the Wnt inhibitor notum and the Activin inhibitor follistatin in a cluster of cells at the anterior-most tip of the regenerating head - the anterior regeneration pole - and in surrounding stem cell progeny. Depletion of Smed-zicA and Smed-FoxD by RNAi abolishes notum and follistatin expression at the pole and inhibits head formation downstream of initial polarity decisions. We suggest a model in which ZicA and FoxD transcription factors synergize to control the formation of Notum- and Follistatin-producing anterior pole cells. Pole formation might constitute an early step in regeneration, resulting in a signaling center that orchestrates cellular events in the growing tissue. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Aspiration pneumonia after concurrent chemoradiotherapy for head and neck cancer.

    PubMed

    Xu, Beibei; Boero, Isabel J; Hwang, Lindsay; Le, Quynh-Thu; Moiseenko, Vitali; Sanghvi, Parag R; Cohen, Ezra E W; Mell, Loren K; Murphy, James D

    2015-04-15

    Aspiration pneumonia represents an under-reported complication of chemoradiotherapy in patient with head and neck cancer. The objective of the current study was to evaluate the incidence, risk factors, and mortality of aspiration pneumonia in a large cohort of patients with head and neck cancer who received concurrent chemoradiotherapy. Patients who had head and neck cancer diagnosed between 2000 and 2009 were identified from the Surveillance, Epidemiology, and End Results-Medicare database. Aspiration pneumonia was identified from Medicare billing claims. The cumulative incidence, risk factors, and survival after aspiration pneumonia were estimated and compared with a noncancer population. Of 3513 patients with head and neck cancer, 801 developed aspiration pneumonia at a median of 5 months after initiating treatment. The 1-year and 5-year cumulative incidence of aspiration pneumonia was 15.8% and 23.8%, respectively, for patients with head and neck cancer and 3.6% and 8.7%, respectively, for noncancer controls. Among the patients with cancer, multivariate analysis identified independent risk factors (P < .05) for aspiration pneumonia, including hypopharyngeal and nasopharyngeal tumors, male gender, older age, increased comorbidity, no surgery before radiation, and care received at a teaching hospital. Among the patients with cancer who experienced aspiration pneumonia, 674 (84%) were hospitalized; and, of these, 301 (45%) were admitted to an intensive care unit. The 30-day mortality rate after hospitalization for aspiration pneumonia was 32.5%. Aspiration pneumonia was associated with a 42% increased risk of death (hazard ratio, 1.42; P < .001) after controlling for confounders. The current results indicated that nearly 25% of elderly patients will develop aspiration pneumonia within 5 years after receiving chemoradiotherapy for head and neck cancer. A better understanding of mitigating factors will help identify patients who are at risk for this potentially lethal complication. © 2014 American Cancer Society.

  3. Pedestrians injured by automobiles: risk factors for cervical spine injuries.

    PubMed

    Yanar, Hakan; Demetriades, Demetrios; Hadjizacharia, Pantelis; Hatzizacharia, Pantelis; Nomoto, Shirley; Salim, Ali; Inaba, Kenji; Rhee, Peter; Chan, Linda S

    2007-12-01

    Diagnosis of cervical spine injuries (CSI) in multitrauma patients, especially in the presence of head trauma, can be difficult. Identification of risk factors associated with CSI can help avoid missed or delayed diagnosis. Trauma registry study of pedestrian injuries caused by being hit by an automobile. Data abstracted for each patient included age, gender, Glasgow Coma Score on admission, Injury Severity Score, Abbreviated Injury Scale (AIS) for each body area, level of cervical spine injuries, and associated injuries. The incidence of spine injuries was derived for 4 age groups (14 years and younger, 15 to 55 years, 56 to 65 years, and older than 65 years). Logistic regression analysis was performed to identify risk factors associated with CSI. There were 8,401 pedestrian injuries caused by automobiles, and 178 patients (2.1%) had CSI. Incidence of CSI increased with age (0.3% in the age group 14 years and younger, 2.2% in the group 15 to 55 years, 3.7% in the group 56 to 65 years, and 4.4% in the group older than 65 years). Using the youngest age group (14 years and younger) as reference, relative risk of CSI in the other groups was 7.0, 12.1, and 14.2, respectively (p < 0.0001). Patients with severe head trauma (AIS > 3) were significantly more likely to have CSI than patients with less severe head injuries (AIS 3), severe chest trauma (AIS > 3), pelvic fracture, and femur fracture as independent risk factors for CSI. Incidence of CSI after injuries to pedestrians hit by automobiles increases with age and severity of head trauma. Age, severe head trauma, severe chest trauma, pelvic fracture, and femur fractures are independent predictors of CSI.

  4. Singularity in the Laboratory Frame Angular Distribution Derived in Two-Body Scattering Theory

    ERIC Educational Resources Information Center

    Dick, Frank; Norbury, John W.

    2009-01-01

    The laboratory (lab) frame angular distribution derived in two-body scattering theory exhibits a singularity at the maximum lab scattering angle. The singularity appears in the kinematic factor that transforms the centre of momentum (cm) angular distribution to the lab angular distribution. We show that it is caused in the transformation by the…

  5. Video analysis of head blows leading to concussion in competition Taekwondo.

    PubMed

    Koh, Jae O; Watkinson, E Jane; Yoon, Yong-Jin

    2004-12-01

    To analyse the situational and contextual factors surrounding concussions and head blows in Taekwondo. Prospective design. Direct observation, subject interview and videotape recording used. A total of 2328 competitors participated in the 2001 tournament, South Korea. All matches were recorded on videotape. All recipients of head blows were interviewed by athletic therapists and the researcher immediately after the match. The videotapes of concussions and head blows were analysed. A total of 1009 head blows including concussions were analysed. Head blows and concussions were most evident when the attacker was situated in a closed stance and received a single roundhouse kick. The most frequent anatomical site of the head impact was the temporal region. The frequency of head blows and concussions is high in Taekwondo. Development of blocking skills, safety education, rigorous enforcement of the competition rules and improvement of head-gear are recommended.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothstein, Ira Z.; Stewart, Iain W.

    Starting with QCD, we derive an effective field theory description for forward scattering and factorization violation as part of the soft-collinear effective field theory (SCET) for high energy scattering. These phenomena are mediated by long distance Glauber gluon exchanges, which are static in time, localized in the longitudinal distance, and act as a kernel for forward scattering where |t| << s. In hard scattering, Glauber gluons can induce corrections which invalidate factorization. With SCET, Glauber exchange graphs can be calculated explicitly, and are distinct from graphs involving soft, collinear, or ultrasoft gluons. We derive a complete basis of operators whichmore » describe the leading power effects of Glauber exchange. Key ingredients include regulating light-cone rapidity singularities and subtractions which prevent double counting. Our results include a novel all orders gauge invariant pure glue soft operator which appears between two collinear rapidity sectors. The 1-gluon Feynman rule for the soft operator coincides with the Lipatov vertex, but it also contributes to emissions with ≥ 2 soft gluons. Our Glauber operator basis is derived using tree level and one-loop matching calculations from full QCD to both SCET II and SCET I. The one-loop amplitude’s rapidity renormalization involves mixing of color octet operators and yields gluon Reggeization at the amplitude level. The rapidity renormalization group equation for the leading soft and collinear functions in the forward scattering cross section are each given by the BFKL equation. Various properties of Glauber gluon exchange in the context of both forward scattering and hard scattering factorization are described. For example, we derive an explicit rule for when eikonalization is valid, and provide a direct connection to the picture of multiple Wilson lines crossing a shockwave. In hard scattering operators Glauber subtractions for soft and collinear loop diagrams ensure that we are not sensitive to the directions for soft and collinear Wilson lines. Conversely, certain Glauber interactions can be absorbed into these soft and collinear Wilson lines by taking them to be in specific directions. Finally, we also discuss criteria for factorization violation.« less

  7. The Prediction of Elementary School Failure Among High Risk Children.

    ERIC Educational Resources Information Center

    Goodstein, H. A.; And Others

    This report briefly summarizes the educational progress of a sample of children who took part in one of the earliest Head Start programs (1966). The report addresses the following questions: (1) Was participation in Head Start a factor in preventing retention in grade and/or special class placement? (2) Were there differences between Head Start…

  8. Women and the Economics of Divorce in the Contemporary United States.

    ERIC Educational Resources Information Center

    Arendell, Terry J.

    1987-01-01

    Households headed by women are more likely to be poor than those headed by men. The number of impoverished female-headed families is increasing due in part to the rising divorce rate. Other factors are the following: (1) lack of child care; (2) wage discrimination; (3) unfair divorce settlements; and (4) inadequate public assistance. (VM)

  9. Structural-electrical coupling optimisation for radiating and scattering performances of active phased array antenna

    NASA Astrophysics Data System (ADS)

    Wang, Congsi; Wang, Yan; Wang, Zhihai; Wang, Meng; Yuan, Shuai; Wang, Weifeng

    2018-04-01

    It is well known that calculating and reducing of radar cross section (RCS) of the active phased array antenna (APAA) are both difficult and complicated. It remains unresolved to balance the performance of the radiating and scattering when the RCS is reduced. Therefore, this paper develops a structure and scattering array factor coupling model of APAA based on the phase errors of radiated elements generated by structural distortion and installation error of the array. To obtain the optimal radiating and scattering performance, an integrated optimisation model is built to optimise the installation height of all the radiated elements in normal direction of the array, in which the particle swarm optimisation method is adopted and the gain loss and scattering array factor are selected as the fitness function. The simulation indicates that the proposed coupling model and integrated optimisation method can effectively decrease the RCS and that the necessary radiating performance can be simultaneously guaranteed, which demonstrate an important application value in engineering design and structural evaluation of APAA.

  10. Hip replacement in femoral head osteonecrosis: current concepts

    PubMed Central

    Scaglione, Michelangelo; Fabbri, Luca; Celli, Fabio; Casella, Francesco; Guido, Giulio

    2015-01-01

    Summary Osteonecrosis of the femoral head is a destructive disease that usually affects young adults with high functional demands and can have devastating effects on hip joint. The treatment depends on extent and location of the necrosis lesion and on patient’s factors, that suggest disease progression, collapse probability and also implants survival. Non-idiopathic osteonecrosis patients had the worst outcome. There is not a gold standard treatment and frequently it is necessary a multidisciplinary approach. Preservation procedures of the femoral head are the first choice and can be attempted in younger patients without head collapse. Replacement procedure remains the main treatment after failure of preserving procedures and in the late-stage ONFH, involving collapse of the femoral head and degenerative changes to the acetabulum. Resurfacing procedure still has good results but the patient selection is a critical factor. Total hip arthroplasties had historically poor results in patients with osteonecrosis. More recently, reports have shown excellent results, but implant longevity and following revisions are still outstanding problems. PMID:27134633

  11. Combined Henyey-Greenstein and Rayleigh phase function.

    PubMed

    Liu, Quanhua; Weng, Fuzhong

    2006-10-01

    The phase function is an important parameter that affects the distribution of scattered radiation. In Rayleigh scattering, a scatterer is approximated by a dipole, and its phase function is analytically related to the scattering angle. For the Henyey-Greenstein (HG) approximation, the phase function preserves only the correct asymmetry factor (i.e., the first moment), which is essentially important for anisotropic scattering. When the HG function is applied to small particles, it produces a significant error in radiance. In addition, the HG function is applied only for an intensity radiative transfer. We develop a combined HG and Rayleigh (HG-Rayleigh) phase function. The HG phase function plays the role of modulator extending the application of the Rayleigh phase function for small asymmetry scattering. The HG-Rayleigh phase function guarantees the correct asymmetry factor and is valid for a polarization radiative transfer. It approaches the Rayleigh phase function for small particles. Thus the HG-Rayleigh phase function has wider applications for both intensity and polarimetric radiative transfers. For microwave radiative transfer modeling in this study, the largest errors in the brightness temperature calculations for weak asymmetry scattering are generally below 0.02 K by using the HG-Rayleigh phase function. The errors can be much larger, in the 1-3 K range, if the Rayleigh and HG functions are applied separately.

  12. Psychometric Validation of the M. D. Anderson Symptom Inventory-Head and Neck Module in the Spanish Language.

    PubMed

    Sánchez, Daniel; Chala, Andrés; Alvarez, Andrés; Payan, Catalina; Mendoza, Tito; Cleeland, Charles; Sanabria, Alvaro

    2016-06-01

    The assessment of cancer-related symptoms requires culturally adapted and psychometrically validated symptom assessment tools. The M. D. Anderson Symptom Inventory-Head and Neck Module (MDASI-HN) is a useful instrument for measuring symptom burden that was specifically developed for head and neck cancer patients. To validate the Spanish version of the MDASI-HN. We evaluated the psychometric features of the MDASI-HN in patients with head and neck cancer. We evaluated the item-scale correlations and the internal consistency. We conducted principal axis factoring to identify the underlying dimensions as a measure of construct validity. The convergence/concurrent validity was assessed with the University of Washington Quality of Life Questionnaire for Head and Neck Patients, and known-group validity and test-retest reliability also were assessed. One hundred thirty patients were included. The mean ± SD age was 60.5 ± 13.6 years; 68% of patients were male, 42% had laryngeal tumors, and 45.9% had Stage III tumors. Forty-seven percent of the patients underwent surgery, 55% underwent radiotherapy, and 36% underwent chemotherapy. The global Cronbach alpha for the HN module was 0.81. The factor analysis identified two factors (Factor 1: speech, mucus, coughing, and constipation; Factor 2: teeth, taste, sores, swallowing, and skin). The correlation with the global score of the University of Washington Quality of Life was -0.68. The difference in the MDASI-HN scores according to Eastern Cooperative Oncology Group performance status was statistically significant (2.72 vs. 4.01, P = 0.006). The intraclass test-retest correlation was 0.62. The Spanish version of the MDASI-HN is reliable and valid for evaluating cancer-related symptoms in head and neck cancer patients. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  13. Development and calibration of a compact self-sensing atomic force microscope head for micro-nano characterization

    NASA Astrophysics Data System (ADS)

    Guo, Tong; Wang, Siming; Zhao, Jian; Chen, Jinping; Fu, Xing; Hu, Xiaotang

    2011-12-01

    A compact self-sensing atomic force microscope (AFM) head is developed for the micro-nano dimensional measurement. This AFM head works in tapping mode equipped with a commercial self-sensing probe. This kind of probe can benefit not only from the tuning fork's stable resonant frequency and high quality factor but also from the silicon cantilever's reasonable spring constant. The head is convenient to operate by its simplicity of structure, since it does not need any optical detector to measure the bending of the cantilever. The compact structure makes the head ease to combine with other measuring methods. According to the probe"s characteristics, a method is proposed to quickly calculate the cantilever"s resonance amplitude through measuring its electro-mechanical coupling factor. An experiment system is established based on the nano-measuring machine (NMM) as a high precision positioning stage. Using this system, the approach/retract test is carried out for calibrating the head. The tests can be traced to the meter definition by interferometers in NMM. Experimental results show that the non-linearity error of this AFM head is smaller than 1%, the sensitivity reaches 0.47nm/mV and the measurement stroke is several hundreds of nanometers.

  14. Autism spectrum disorders: head circumference and body length at birth are both relative.

    PubMed

    Grandgeorge, Marine; Lemonnier, Eric; Jallot, Nelle

    2013-09-01

    Although the body length and weight of an infant are related to head circumference, little research on ASDs has examined these factors. Our study compared the head circumferences of neonates who were later diagnosed with ASD with a control group. Additional comparisons on morphological disproportions at birth included the head circumference-to-height and head circumference-to-weight ratios. We recruited 422 children with ASD and 153 typically developing children. Head circumference, body length and weight at birth were collected and standardized as percentile scores according to gestational age and gender. Our results revealed that genuine macrocephaly was significantly higher in children with other pervasive developmental disorders compared with the control group. This difference was not observed with regard to genuine microcephaly. Relative macrocephaly and relative microcephaly were significantly more frequent in children with autism disorder compared with the control group with regard to body length. The differences in relative macrocephaly and microcephaly, as well as in other parameters, between diagnostic subgroups suggest that the presence of several neurological mechanisms plays a role in the later expression of different phenotypes. An increased head circumference-to-body length ratio in newborns may be a factor to follow that could be related to ASD. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  15. Does Head Start differentially benefit children with risks targeted by the program’s service model?☆

    PubMed Central

    Miller, Elizabeth B.; Farkas, George; Duncan, Greg J.

    2015-01-01

    Data from the Head Start Impact Study (N = 3540) were used to test for differential benefits of Head Start after one program year and after kindergarten on pre-academic and behavior outcomes for children at risk in the domains targeted by the program’s comprehensive services. Although random assignment to Head Start produced positive treatment main effects on children’s pre-academic skills and behavior problems, residualized growth models showed that random assignment to Head Start did not differentially benefit the pre-academic skills of children with risk factors targeted by the Head Start service model. The models showed detrimental impacts of Head Start for maternal-reported behavior problems of high-risk children, but slightly more positive impacts for teacher-reported behavior. Policy implications for Head Start are discussed. PMID:26379369

  16. Hole mobilities and the effective Hall factor in p-type GaAs

    NASA Astrophysics Data System (ADS)

    Wenzel, M.; Irmer, G.; Monecke, J.; Siegel, W.

    1997-06-01

    We prove the effective Hall factor in p-GaAs to be larger than values discussed in the literature up to now. The scattering rates for the relevant scattering mechanisms in p-GaAs have been recalculated after critical testing the existing models. These calculations allow to deduce theoretical drift and theoretical Hall mobilities as functions of temperature which can be compared with measured data. Theoretical Hall factors in the heavy and light hole bands and an effective Hall factor result. The calculated room temperature values of the drift mobility and of the effective Hall factor are 118 cm2/V s and 3.6, respectively. The fitted acoustic deformation potential E1=7.9 eV and the fitted optical coupling constant DK=1.24×1011 eV/m are close to values published before. It is shown that the measured strong dependence of the Hall mobility on the Hall concentration is not mainly caused by scattering by ionized impurities but by the dependence of the effective Hall factor on the hole concentration.

  17. A study on scattering correction for γ-photon 3D imaging test method

    NASA Astrophysics Data System (ADS)

    Xiao, Hui; Zhao, Min; Liu, Jiantang; Chen, Hao

    2018-03-01

    A pair of 511KeV γ-photons is generated during a positron annihilation. Their directions differ by 180°. The moving path and energy information can be utilized to form the 3D imaging test method in industrial domain. However, the scattered γ-photons are the major factors influencing the imaging precision of the test method. This study proposes a γ-photon single scattering correction method from the perspective of spatial geometry. The method first determines possible scattering points when the scattered γ-photon pair hits the detector pair. The range of scattering angle can then be calculated according to the energy window. Finally, the number of scattered γ-photons denotes the attenuation of the total scattered γ-photons along its moving path. The corrected γ-photons are obtained by deducting the scattered γ-photons from the original ones. Two experiments are conducted to verify the effectiveness of the proposed scattering correction method. The results concluded that the proposed scattering correction method can efficiently correct scattered γ-photons and improve the test accuracy.

  18. Impact of creatine kinase correction on the predictive value of S-100B after mild traumatic brain injury.

    PubMed

    Bazarian, Jeffrey J; Beck, Christopher; Blyth, Brian; von Ahsen, Nicolas; Hasselblatt, Martin

    2006-01-01

    To validate a correction factor for the extracranial release of the astroglial protein, S-100B, based on concomitant creatine kinase (CK) levels. The CK- S-100B relationship in non-head injured marathon runners was used to derive a correction factor for the extracranial release of S-100B. This factor was then applied to a separate cohort of 96 mild traumatic brain injury (TBI) patients in whom both CK and S-100B levels were measured. Corrected S-100B was compared to uncorrected S-100B for the prediction of initial head CT, three-month headache and three-month post concussive syndrome (PCS). Corrected S-100B resulted in a statistically significant improvement in the prediction of 3-month headache (area under curve [AUC] 0.46 vs 0.52, p=0.02), but not PCS or initial head CT. Using a cutoff that maximizes sensitivity (> or = 90%), corrected S-100B improved the prediction of initial head CT scan (negative predictive value from 75% [95% CI, 2.6%, 67.0%] to 96% [95% CI: 83.5%, 99.8%]). Although S-100B is overall poorly predictive of outcome, a correction factor using CK is a valid means of accounting for extracranial release. By increasing the proportion of mild TBI patients correctly categorized as low risk for abnormal head CT, CK-corrected S100-B can further reduce the number of unnecessary brain CT scans performed after this injury.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Christopher Matthew

    The proton form factors provide information on the fundamental properties of the proton and provide a test for models based on QCD. In 1998 at Jefferson Lab (JLAB) in Newport News, VA, experiment E93026 measured the inclusive e-p scattering cross section from a polarized ammonia ( 15NH 3) target at a four momentum transfer squared of Q 2 = 0.5 (GeV/c) 2. Longitudinally polarized electrons were scattered from the polarized target and the scattered electron was detected. Data has been analyzed to obtain the asymmetry from elastically scattered electrons from hydrogen in 15NH 3. The asymmetry, A p, has beenmore » used to determine the proton elastic form factor G Ep. The result is consistent with the dipole model and data from previous experiments. However, due to the choice of kinematics, the uncertainty in the measurement is large.« less

  20. Long term measurements of optical properties and their hygroscopic enhancement

    NASA Astrophysics Data System (ADS)

    Hervo, M.; Sellegri, K.; Pichon, J. M.; Roger, J. C.; Laj, P.

    2014-11-01

    Optical properties of aerosols were measured from the GAW Puy de Dôme station (1465 m) over a seven year period (2006-2012). The impact of hygroscopicity on aerosol optical properties was calculated over a two year period (2010-2011). The analysis of the spatial and temporal variability of the optical properties showed that while no long term trend was found, a clear seasonal and diurnal variation was observed on the extensive parameters (scattering, absorption). Scattering and absorption coefficients were highest during the warm season and daytime, in concordance with the seasonality and diurnal variation of the PBL height reaching the site. Intensive parameters (single scattering albedo, asymmetry factor, refractive index) did not show such a strong diurnal variability, but still indicated different values depending on the season. Both extensive and intensive optical parameters were sensitive to the air mass origin. A strong impact of hygroscopicity on aerosol optical properties was calculated, mainly on aerosol scattering, with a dependence on the aerosol type. At 90% humidity, the scattering factor enhancement (fσsca) was more than 4.4 for oceanic aerosol that have mixed with a pollution plume. Consequently, the aerosol radiative forcing was estimated to be 2.8 times higher at RH = 90% and 1.75 times higher at ambient RH when hygroscopic growth of the aerosol was considered. The hygroscopicity enhancement factor of the scattering coefficient was parameterized as a function of humidity and air mass type.

  1. Factors affecting the aluminium content of human femoral head and neck.

    PubMed

    Zioła-Frankowska, Anetta; Dąbrowski, Mikołaj; Kubaszewski, Łukasz; Rogala, Piotr; Frankowski, Marcin

    2015-11-01

    Tissues for the study were obtained intraoperatively during hip replacement procedures from 96 patients. In all the cases, the indication for this treatment was primary or secondary degenerative changes in the hip joint. The subject of the study was the head and neck of the femur, resected in situ. Aluminium concentrations measured in femoral head and neck samples from patients aged between 25 and 91 were varied. Statistical methods were applied to determine the variations in relation to the parameters from the background survey. Significant differences in the aluminium content of femoral head samples were observed between patients under and over 60 years of age. Based on the results, it was confirmed that the aluminium accumulates in bones over a lifetime. The study showed that the content of aluminium in the head and neck of the femur depends on the factors such as: type of medicines taken, contact with chemicals at work, differences in body anatomy and sex. The study on the levels of aluminium in bones and the factors affecting its concentration is a valuable source of information for further research on the role of aluminium in bone diseases. Based on the investigations, it was found that the GF-AAS technique is the best analytical tool for routine analysis of aluminium in complex matrix samples. The use of femoral heads in the investigations was approved by the Bioethics Committee of the University of Medical Sciences in Poznań (Poland). Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Analysis of long wavelength electromagnetic scattering by a magnetized cold plasma prolate spheroid

    NASA Astrophysics Data System (ADS)

    Ahmadizadeh, Yadollah; Jazi, Bahram; Abdoli-Arani, Abbas

    2013-08-01

    Using dielectric permittivity tensor of the magnetized prolate plasma, the scattering of long wavelength electromagnetic waves from the mentioned object is studied. The resonance frequency and differential scattering cross section for the backward scattered waves are presented. Consistency between the resonance frequency in this configuration and results obtained for spherical plasma are investigated. Finally, the effective factors on obtained results such as incident wave polarization, the frequency of the incident wave, the plasma frequency and the cyclotron frequency are analyzed.

  3. Head circumference and height abnormalities in autism revisited: the role of pre- and perinatal risk factors.

    PubMed

    Schrieken, Margo; Visser, Janne; Oosterling, Iris; van Steijn, Daphne; Bons, Daniëlle; Draaisma, Jos; van der Gaag, Rutger-Jan; Buitelaar, Jan; Donders, Rogier; Rommelse, Nanda

    2013-01-01

    Pre/perinatal risk factors and body growth abnormalities have been studied frequently as early risk markers in autism spectrum disorder (ASD), yet their interrelatedness in ASD has received very little research attention. This is surprising, given that pre/perinatal risk factors can have a substantial impact on growth trajectories in the first years of life. We aimed to determine which pre/perinatal factors were more prevalent in ASD children and if these factors differentially influenced body growth in ASD and control children. A total of 96 ASD and 163 control children matched for gender participated. Data of growth of head size and body length during the first 13 months of life were collected. Data on pre/perinatal risk factors were retrospectively collected through standardized questionnaires. Results indicated that after matching for SES, prematurity/low birth weight and being first born were more prevalent in the ASD versus the control group. In addition, with increasing age children with ASD tended to have a proportionally smaller head circumference compared to their height. However, the effect of prematurity/low birth weight on head growth corrected for height was significantly different in ASD and control children: premature/low birth weight control children showed a disproportionate larger head circumference in relation to height during their first year of life, whereas this effect was absent in premature/low birth weight ASD children. This may suggest that the etiology of abnormal growth is potentially different in ASD and control children: where abnormal growth in control children is related to suboptimal conditions in the uterus, abnormal growth in ASD may be more strongly related to the causal factors that also increase the risk for ASD. However, prospective studies measuring growth and ASD characteristics in both premature/low birth weight and a terme children are necessary to support this conclusion.

  4. Human Papilloma Virus (HPV) Induced Head & Neck Squamous Cell Carcinoma: A Comprehensive Retrospect

    PubMed Central

    Nishat, Roquaiya; Ramachandra, Sujatha; Kumar, Harish; Bandyopadhyay, Alokenath

    2015-01-01

    Head and Neck Squamous Cell Carcinoma accounts for the sixth most common malignancy occurring worldwide with tobacco and alcohol being the two well established risk factors. In the recent years, substantial evidence has been obtained that Human Papilloma Virus (HPV) associated head and neck cancers are on the rise. This article provides an insight into the structure of HPV genome, molecular pathogenesis, detection methods and clinical implications of HPV positive Head and Neck Squamous Cell Carcinoma. PMID:26266234

  5. A symmetrical subtraction combined with interpolated values for eliminating scattering from fluorescence EEM data

    NASA Astrophysics Data System (ADS)

    Xu, Jing; Liu, Xiaofei; Wang, Yutian

    2016-08-01

    Parallel factor analysis is a widely used method to extract qualitative and quantitative information of the analyte of interest from fluorescence emission-excitation matrix containing unknown components. Big amplitude of scattering will influence the results of parallel factor analysis. Many methods of eliminating scattering have been proposed. Each of these methods has its advantages and disadvantages. The combination of symmetrical subtraction and interpolated values has been discussed. The combination refers to both the combination of results and the combination of methods. Nine methods were used for comparison. The results show the combination of results can make a better concentration prediction for all the components.

  6. Breaking the diffraction barrier using coherent anti-Stokes Raman scattering difference microscopy.

    PubMed

    Wang, Dong; Liu, Shuanglong; Chen, Yue; Song, Jun; Liu, Wei; Xiong, Maozhen; Wang, Guangsheng; Peng, Xiao; Qu, Junle

    2017-05-01

    We propose a method to improve the resolution of coherent anti-Stokes Raman scattering microscopy (CARS), and present a theoretical model. The proposed method, coherent anti-Stokes Raman scattering difference microscopy (CARS-D), is based on the intensity difference between two differently acquired images. One being the conventional CARS image, and the other obtained when the sample is illuminated by a doughnut shaped spot. The final super-resolution CARS-D image is constructed by intensity subtraction of these two images. However, there is a subtractive factor between them, and the theoretical model sets this factor to obtain the best imaging effect.

  7. Experiment and application of soft x-ray grazing incidence optical scattering phenomena

    NASA Astrophysics Data System (ADS)

    Chen, Shuyan; Li, Cheng; Zhang, Yang; Su, Liping; Geng, Tao; Li, Kun

    2017-08-01

    For short wavelength imaging systems,surface scattering effects is one of important factors degrading imaging performance. Study of non-intuitive surface scatter effects resulting from practical optical fabrication tolerances is a necessary work for optical performance evaluation of high resolution short wavelength imaging systems. In this paper, Soft X-ray optical scattering distribution is measured by a soft X-ray reflectometer installed by my lab, for different sample mirrors、wavelength and grazing angle. Then aim at space solar telescope, combining these scattered light distributions, and surface scattering numerical model of grazing incidence imaging system, PSF and encircled energy of optical system of space solar telescope are computed. We can conclude that surface scattering severely degrade imaging performance of grazing incidence systems through analysis and computation.

  8. Environmental and Genetic Factors Explain Differences in Intraocular Scattering.

    PubMed

    Benito, Antonio; Hervella, Lucía; Tabernero, Juan; Pennos, Alexandros; Ginis, Harilaos; Sánchez-Romera, Juan F; Ordoñana, Juan R; Ruiz-Sánchez, Marcos; Marín, José M; Artal, Pablo

    2016-01-01

    To study the relative impact of genetic and environmental factors on the variability of intraocular scattering within a classical twin study. A total of 64 twin pairs, 32 monozygotic (MZ) (mean age: 54.9 ± 6.3 years) and 32 dizygotic (DZ) (mean age: 56.4 ± 7.0 years), were measured after a complete ophthalmologic exam had been performed to exclude all ocular pathologies that increase intraocular scatter as cataracts. Intraocular scattering was evaluated by using two different techniques based on a straylight parameter log(S) estimation: a compact optical instrument based in the principle of optical integration and a psychophysical measurement. Intraclass correlation coefficients (ICC) were used as descriptive statistics of twin resemblance, and genetic models were fitted to estimate heritability. No statistically significant difference was found for MZ and DZ groups for age (P = 0.203), best-corrected visual acuity (P = 0.626), cataract gradation (P = 0.701), sex (P = 0.941), optical log(S) (P = 0.386), or psychophysical log(S) (P = 0.568), with only a minor difference in equivalent sphere (P = 0.008). Intraclass correlation coefficients between siblings were similar for scatter parameters: 0.676 in MZ and 0.471 in DZ twins for optical log(S); 0.533 in MZ twins and 0.475 in DZ twins for psychophysical log(S). For equivalent sphere, ICCs were 0.767 in MZ and 0.228 in DZ twins. Conservative estimates of heritability for the measured scattering parameters were 0.39 and 0.20, respectively. Correlations of intraocular scatter (straylight) parameters in the groups of identical and nonidentical twins were similar. Heritability estimates were of limited magnitude, suggesting that genetic and environmental factors determine the variance of ocular straylight in healthy middle-aged adults.

  9. Estimation of head tissue-specific exposure from mobile phones based on measurements in the homogeneous SAM head.

    PubMed

    Gosselin, Marie-Christine; Kühn, Sven; Crespo-Valero, Pedro; Cherubini, Emilio; Zefferer, Marcel; Christ, Andreas; Kuster, Niels

    2011-09-01

    The maximum spatial peak exposure of each commercial mobile phone determined in compliance with the relevant safety and product standards is publicly available. However, this information is not sufficient for epidemiological studies aiming to correlate the use of mobile phones with specific cancers or to behavioral alterations, as the dominant location of the exposure may be anywhere in the head between the chin to above the ear, depending on the phone design. The objective of this study was to develop a methodology to determine tissue-specific exposure by expanding the post-processing of the measured surface or volume scans using standardized compliance testing equipment, that is, specific absorption rate (SAR) scanners. The transformation matrix was developed using the results from generic dipoles to evaluate the relation between the SAR in many brain regions of the Virtual Family anatomical phantoms and in virtual brain regions mapped onto the homogeneous SAM head. A set of transformation factors was derived to correlate the SAR induced in the SAM head to the SAR in the anatomical heads. The evaluation included the uncertainty associated with each factor, arising from the anatomical differences between the phantoms (typically less than 6 dB (4×)). The applicability of these factors was validated by performing simulations of four head models exposed to four realistic mobile phone models. The new methodology enables the reliable determination of the maximum and averaged exposure of specific tissues and functional brain regions to mobile phones when combined with mobile phone power control data, and therefore greatly strengthens epidemiological evaluations and improves information for the consumer. Copyright © 2011 Wiley-Liss, Inc.

  10. Positive Factors Influencing the Advancement of Women to the Role of Head Athletic Trainer in the National Collegiate Athletic Association Divisions II and III.

    PubMed

    Mazerolle, Stephanie M; Eason, Christianne M

    2016-07-01

    Research suggests that women do not pursue leadership positions in athletic training due to a variety of reasons, including family challenges, organizational constraints, and reluctance to hold the position. The literature has been focused on the National Collegiate Athletic Association Division I setting, limiting our full understanding. To examine factors that help women as they worked toward the position of head athletic trainer. Qualitative study. Divisions II and III. Seventy-seven women who were employed as head athletic trainers at the Division II or III level participated in our study. Participants were 38 ± 9 (range = 24-57) years old and had an average of 14 ± 8 (range = 1-33) years of athletic training experience. We conducted online interviews. Participants journaled their reflections to a series of open-ended questions pertaining to their experiences as head athletic trainers. Data were analyzed using a general inductive approach. Credibility was secured by peer review and researcher triangulation. Three organizational facilitators emerged from the data, workplace atmosphere, mentors, and past work experiences. These organizational factors were directly tied to aspects within the athletic trainer's employment setting that allowed her to enter the role. One individual-level facilitator was found: personal attributes that were described as helpful for women in transitioning to the role of the head athletic trainer. Participants discussed being leaders and persisting toward their career goals. Women working in Divisions II and III experience similar facilitators to assuming the role of head athletic trainer as those working in the Division I setting. Divisions II and III were viewed as more favorable for women seeking the role of head athletic trainer, but like those in the role in the Division I setting, women must have leadership skills.

  11. Tissue mimicking simulations for temporal enhanced ultrasound-based tissue typing

    NASA Astrophysics Data System (ADS)

    Bayat, Sharareh; Imani, Farhad; Gerardo, Carlos D.; Nir, Guy; Azizi, Shekoofeh; Yan, Pingkun; Tahmasebi, Amir; Wilson, Storey; Iczkowski, Kenneth A.; Lucia, M. Scott; Goldenberg, Larry; Salcudean, Septimiu E.; Mousavi, Parvin; Abolmaesumi, Purang

    2017-03-01

    Temporal enhanced ultrasound (TeUS) is an imaging approach where a sequence of temporal ultrasound data is acquired and analyzed for tissue typing. Previously, in a series of in vivo and ex vivo studies we have demonstrated that, this approach is effective for detecting prostate and breast cancers. Evidences derived from our experiments suggest that both ultrasound-signal related factors such as induced heat and tissue-related factors such as the distribution and micro-vibration of scatterers lead to tissue typing information in TeUS. In this work, we simulate mechanical micro-vibrations of scatterers in tissue-mimicking phantoms that have various scatterer densities reflecting benign and cancerous tissue structures. Finite element modeling (FEM) is used for this purpose where the vertexes are scatterers representing cell nuclei. The initial positions of scatterers are determined by the distribution of nuclei segmented from actual digital histology scans of prostate cancer patients. Subsequently, we generate ultrasound images of the simulated tissue structure using the Field II package resulting in a temporal enhanced ultrasound. We demonstrate that the micro-vibrations of scatterers are captured by temporal ultrasound data and this information can be exploited for tissue typing.

  12. Decomposition of Atmospheric Aerosol Phase Function by Particle Size and Morphology via Single Particle Scattering Measurements

    NASA Astrophysics Data System (ADS)

    Aptowicz, K. B.; Pan, Y.; Martin, S.; Fernandez, E.; Chang, R.; Pinnick, R. G.

    2013-12-01

    We report upon an experimental approach that provides insight into how particle size and shape affect the scattering phase function of atmospheric aerosol particles. Central to our approach is the design of an apparatus that measures the forward and backward scattering hemispheres (scattering patterns) of individual atmospheric aerosol particles in the coarse mode range. The size and shape of each particle is discerned from the corresponding scattering pattern. In particular, autocorrelation analysis is used to differentiate between spherical and non-spherical particles, the calculated asphericity factor is used to characterize the morphology of non-spherical particles, and the integrated irradiance is used for particle sizing. We found the fraction of spherical particles decays exponentially with particle size, decreasing from 11% for particles on the order of 1 micrometer to less than 1% for particles over 5 micrometer. The average phase functions of subpopulations of particles, grouped by size and morphology, are determined by averaging their corresponding scattering patterns. The phase functions of spherical and non-spherical atmospheric particles are shown to diverge with increasing size. In addition, the phase function of non-spherical particles is found to vary little as a function of the asphericity factor.

  13. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... shield as prescribed in § 179.16(c)(1). (d) Alternative tank car tanks for materials poisonous by... the alternative tank car jacket and head shield. When the jacket and head shield are made from any...., the thickness to be added to the jacket and head shield must be increased by a factor of 1.157...

  14. Factors affecting breeding season survival of red-headed woodpeckers in South Carolina

    Treesearch

    John C. Kilgo; Mark Vukovich

    2012-01-01

    Red-headed woodpecker (Melanerpes erythrocephalus) populations have declined in the United States and Canada over the past 40 years. However, few demographic studies have been published on the species and none have addressed adult survival. During 2006¨C2007, we estimated survival probabilities of 80 radio-tagged red-headed woodpeckers during the breeding season in...

  15. Errors induced by the neglect of polarization in radiance calculations for Rayleigh-scattering atmospheres

    NASA Technical Reports Server (NTRS)

    Mishchenko, M. I.; Lacis, A. A.; Travis, L. D.

    1994-01-01

    Although neglecting polarization and replacing the rigorous vector radiative transfer equation by its approximate scalar counterpart has no physical background, it is a widely used simplification when the incident light is unpolarized and only the intensity of the reflected light is to be computed. We employ accurate vector and scalar multiple-scattering calculations to perform a systematic study of the errors induced by the neglect of polarization in radiance calculations for a homogeneous, plane-parallel Rayleigh-scattering atmosphere (with and without depolarization) above a Lambertian surface. Specifically, we calculate percent errors in the reflected intensity for various directions of light incidence and reflection, optical thicknesses of the atmosphere, single-scattering albedos, depolarization factors, and surface albedos. The numerical data displayed can be used to decide whether or not the scalar approximation may be employed depending on the parameters of the problem. We show that the errors decrease with increasing depolarization factor and/or increasing surface albedo. For conservative or nearly conservative scattering and small surface albedos, the errors are maximum at optical thicknesses of about 1. The calculated errors may be too large for some practical applications, and, therefore, rigorous vector calculations should be employed whenever possible. However, if approximate scalar calculations are used, we recommend to avoid geometries involving phase angles equal or close to 0 deg and 90 deg, where the errors are especially significant. We propose a theoretical explanation of the large vector/scalar differences in the case of Rayleigh scattering. According to this explanation, the differences are caused by the particular structure of the Rayleigh scattering matrix and come from lower-order (except first-order) light scattering paths involving right scattering angles and right-angle rotations of the scattering plane.

  16. Prevalence of and factors associated with head impact during falls in older adults in long-term care

    PubMed Central

    Schonnop, Rebecca; Yang, Yijian; Feldman, Fabio; Robinson, Erin; Loughin, Marie; Robinovitch, Stephen N.

    2013-01-01

    Background: Falls cause more than 60% of head injuries in older adults. Lack of objective evidence on the circumstances of these events is a barrier to prevention. We analyzed video footage to determine the frequency of and risk factors for head impact during falls in older adults in 2 long-term care facilities. Methods: Over 39 months, we captured on video 227 falls involving 133 residents. We used a validated questionnaire to analyze the mechanisms of each fall. We then examined whether the probability for head impact was associated with upper-limb protective responses (hand impact) and fall direction. Results: Head impact occurred in 37% of falls, usually onto a vinyl or linoleum floor. Hand impact occurred in 74% of falls but had no significant effect on the probability of head impact (p = 0.3). An increased probability of head impact was associated with a forward initial fall direction, compared with backward falls (odds ratio [OR] 2.7, 95% confidence interval [CI] 1.3–5.9) or sideways falls (OR 2.8, 95% CI 1.2–6.3). In 36% of sideways falls, residents rotated to land backwards, which reduced the probability of head impact (OR 0.2, 95% CI 0.04–0.8). Interpretation: Head impact was common in observed falls in older adults living in long-term care facilities, particularly in forward falls. Backward rotation during descent appeared to be protective, but hand impact was not. Attention to upper-limb strength and teaching rotational falling techniques (as in martial arts training) may reduce fall-related head injuries in older adults. PMID:24101612

  17. Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography.

    PubMed

    Vernekohl, Don; Tzoumas, Stratis; Zhao, Wei; Xing, Lei

    2018-05-25

    X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses x-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When polarized x rays are used, it is possible to reduce the scatter contamination significantly by placing detectors perpendicular to the polarization direction. This study quantifies scatter contamination for polarized and unpolarized x-ray excitation and determines the advantages of scatter reduction. The amount of scatter in preclinical XFCT is quantified in Monte Carlo simulations. The fluorescent x rays are emitted isotropically, while scattered x rays propagate in polarization direction. The magnitude of scatter contamination is studied in XFCT simulations of a mouse phantom. In this study, the contrast agent gold is examined as an example, but a scatter reduction from polarized excitation is also expected for other elements. The scatter reduction capability is examined for different polarization intensities with a monoenergetic x-ray excitation energy of 82 keV. The study evaluates two different geometrical shapes of CZT detectors which are modeled with an energy resolution of 1 keV FWHM at an x-ray energy of 80 keV. Benefits of a detector placement perpendicular to the polarization direction are shown in iterative and analytic image reconstruction including scatter correction. The contrast to noise ratio (CNR) and the normalized mean square error (NMSE) are analyzed and compared for the reconstructed images. A substantial scatter reduction for common detector sizes was achieved for 100% and 80% linear polarization while lower polarization intensities provide a decreased scatter reduction. By placing the detector perpendicular to the polarization direction, a scatter reduction by factor up to 5.5 can be achieved for common detector sizes. The image reconstruction showed that for a scatter magnitude decrease by a factor of 2.4, the molecular sensitivity could almost be doubled. Scatter reduction lowers the amount of noise in the projection datasets and reconstructed images which enhance molecular sensitivity at equal dose. The results support the use of linear polarized x rays to reduce scatter in XFCT imaging. © 2018 American Association of Physicists in Medicine.

  18. Polarization observables and T-noninvariance in the weak charged current induced electron proton scattering

    NASA Astrophysics Data System (ADS)

    Fatima, A.; Sajjad Athar, M.; Singh, S. K.

    2018-06-01

    In this work, we have studied the total scattering cross section (σ, differential scattering cross section ( dσ/d Q2) as well as the longitudinal ( P_L(Ee,Q2)), perpendicular ( PP(Ee,Q2)), and transverse ( PT(Ee,Q2)) components of the polarization of the final hadron ( n, Λ and Σ0) produced in the electron proton scattering induced by the weak charged current. We have not assumed T-invariance which allows the transverse component of the hadron polarization perpendicular to the production plane to be non-zero. The numerical results are presented for all the above observables and their dependence on the axial vector form factor and the weak electric form factor are discussed. The present study enables the determination of the axial vector nucleon-hyperon transition form factors at high Q2 in the strangeness sector which can provide a test of the symmetries of the weak hadronic currents like T-invariance and SU(3) symmetry while assuming the hypothesis of conserved vector current and partial conservation of axial vector current.

  19. Towards a Resolution of the Proton Form Factor Problem: New Electron and Positron Scattering Data

    NASA Astrophysics Data System (ADS)

    Adikaram, D.; Rimal, D.; Weinstein, L. B.; Raue, B.; Khetarpal, P.; Bennett, R. P.; Arrington, J.; Brooks, W. K.; Adhikari, K. P.; Afanasev, A. V.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Avakian, H.; Ball, J.; Battaglieri, M.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Careccia, S.; Celentano, A.; Chandavar, S.; Charles, G.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dodge, G. E.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Filippi, A.; Fleming, J. A.; Fradi, A.; Garillon, B.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guegan, B.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Hattawy, M.; Hicks, K.; Holtrop, M.; Hughes, S. M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Jenkins, D.; Jiang, H.; Jo, H. S.; Joo, K.; Joosten, S.; Kalantarians, N.; Keller, D.; Khandaker, M.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Koirala, S.; Kubarovsky, V.; Kuhn, S. E.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mattione, P.; Mayer, M.; McKinnon, B.; Mestayer, M. D.; Meyer, C. A.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Moody, C. I.; Moutarde, H.; Movsisyan, A.; Camacho, C. Munoz; Nadel-Turonski, P.; Niccolai, S.; Niculescu, G.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Peña, C.; Pisano, S.; Pogorelko, O.; Price, J. W.; Procureur, S.; Prok, Y.; Protopopescu, D.; Puckett, A. J. R.; Ripani, M.; Rizzo, A.; Rosner, G.; Rossi, P.; Roy, P.; Sabatié, F.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seder, E.; Sharabian, Y. G.; Simonyan, A.; Skorodumina, I.; Smith, E. S.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Sparveris, N.; Stepanyan, S.; Stoler, P.; Strauch, S.; Sytnik, V.; Taiuti, M.; Tian, Ye; Trivedi, A.; Ungaro, M.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wei, X.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.; Zonta, I.; CLAS Collaboration

    2015-02-01

    There is a significant discrepancy between the values of the proton electric form factor, GEp, extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of GEp from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (ɛ ) and momentum transfer (Q2) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ɛ at Q2=1.45 GeV2 . This measurement is consistent with the size of the form factor discrepancy at Q2≈1.75 GeV2 and with hadronic calculations including nucleon and Δ intermediate states, which have been shown to resolve the discrepancy up to 2 - 3 GeV2 .

  20. Scattering of Airy elastic sheets by a cylindrical cavity in a solid.

    PubMed

    Mitri, F G

    2017-11-01

    The prediction of the elastic scattering by voids (and cracks) in materials is an important process in structural health monitoring, phononic crystals, metamaterials and non-destructive evaluation/imaging to name a few examples. Earlier analytical theories and numerical computations considered the elastic scattering by voids in plane waves of infinite extent. However, current research suggesting the use of (limited-diffracting, accelerating and self-healing) Airy acoustical-sheet beams for non-destructive evaluation or imaging applications in elastic solids requires the development of an improved analytical formalism to predict the scattering efficiency used as a priori information in quantitative material characterization. Based on the definition of the time-averaged scattered power flow density, an analytical expression for the scattering efficiency of a cylindrical empty cavity (i.e., void) encased in an elastic medium is derived for compressional and normally-polarized shear-wave Airy beams. The multipole expansion method using cylindrical wave functions is utilized. Numerical computations for the scattering energy efficiency factors for compressional and shear waves illustrate the analysis with particular emphasis on the Airy beam parameters and the non-dimensional frequency, for various elastic materials surrounding the cavity. The ratio of the compressional to the shear wave speed stimulates the generation of elastic resonances, which are manifested as a series of peaks in the scattering efficiency plots. The present analysis provides an improved method for the computations of the scattering energy efficiency factors using compressional and shear-wave Airy beams in elastic materials as opposed to plane waves of infinite extent. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Achieving a strongly negative scattering asymmetry factor in random media composed of dual-dipolar particles

    NASA Astrophysics Data System (ADS)

    Wang, B. X.; Zhao, C. Y.

    2018-02-01

    Understanding radiative transfer in random media like micro- or nanoporous and particulate materials, allows people to manipulate the scattering and absorption of radiation, as well as opens new possibilities in applications such as imaging through turbid media, photovoltaics, and radiative cooling. A strong-backscattering phase function, i.e., a negative scattering asymmetry parameter g , is of great interest, which can possibly lead to unusual radiative transport phenomena, for instance, Anderson localization of light. Here we demonstrate that by utilizing the structural correlations and second Kerker condition for a disordered medium composed of randomly distributed silicon nanoparticles, a strongly negative scattering asymmetry factor (g ˜-0.5 ) for multiple light scattering can be realized in the near infrared. Based on the multipole expansion of Foldy-Lax equations and quasicrystalline approximation (QCA), we have rigorously derived analytical expressions for the effective propagation constant and scattering phase function for a random system containing spherical particles, by taking the effect of structural correlations into account. We show that as the concentration of scattering particles rises, the backscattering is also enhanced. Moreover, in this circumstance, the transport mean free path is largely reduced and even becomes smaller than that predicted by independent scattering approximation. We further explore the dependent scattering effects, including the modification of electric and magnetic dipole excitations and far-field interference effect, both induced and influenced by the structural correlations, for volume fraction of particles up to fv˜0.25 . Our results have profound implications in harnessing micro- or nanoscale radiative transfer through random media.

  2. Ultrashort optical waveguide excitations in uniaxial silica fibers: elastic collision scenarios.

    PubMed

    Kuetche, Victor K; Youssoufa, Saliou; Kofane, Timoleon C

    2014-12-01

    In this work, we investigate the dynamics of an uniaxial silica fiber under the viewpoint of propagation of ultimately ultrashort optical waveguide channels. As a result, we unveil the existence of three typical kinds of ultrabroadband excitations whose profiles strongly depend upon their angular momenta. Looking forward to surveying their scattering features, we unearth some underlying head-on scenarios of elastic collisions. Accordingly, we address some useful and straightforward applications in nonlinear optics through secured data transmission systems, as well as laser physics and soliton theory with optical soliton dynamics.

  3. A study on independently using static and dynamic light scattering methods to determine the coagulation rate

    NASA Astrophysics Data System (ADS)

    Zhou, Hongwei; Xu, Shenghua; Mi, Li; Sun, Zhiwei; Qin, Yanming

    2014-09-01

    Absolute coagulation rate constants were determined by independently, instead of simultaneously, using static and dynamic light scattering with the requested optical factors calculated by T-matrix method. The aggregating suspensions of latex particles with diameters of 500, 700, and 900 nm, that are all beyond validity limit of the traditional Rayleigh-Debye-Gans approximation, were adopted. The results from independent static and dynamic light scattering measurements were compared with those by simultaneously using static and dynamic light scattering; and three of them show good consistency. We found, theoretically and experimentally, that for independent static light scattering measurements there are blind scattering angles at that the scattering measurements become impossible and the number of blind angles increases rapidly with particle size. For independent dynamic light scattering measurements, however, there is no such a blind angle at all. A possible explanation of the observed phenomena is also presented.

  4. A new theory for X-ray diffraction.

    PubMed

    Fewster, Paul F

    2014-05-01

    This article proposes a new theory of X-ray scattering that has particular relevance to powder diffraction. The underlying concept of this theory is that the scattering from a crystal or crystallite is distributed throughout space: this leads to the effect that enhanced scatter can be observed at the `Bragg position' even if the `Bragg condition' is not satisfied. The scatter from a single crystal or crystallite, in any fixed orientation, has the fascinating property of contributing simultaneously to many `Bragg positions'. It also explains why diffraction peaks are obtained from samples with very few crystallites, which cannot be explained with the conventional theory. The intensity ratios for an Si powder sample are predicted with greater accuracy and the temperature factors are more realistic. Another consequence is that this new theory predicts a reliability in the intensity measurements which agrees much more closely with experimental observations compared to conventional theory that is based on `Bragg-type' scatter. The role of dynamical effects (extinction etc.) is discussed and how they are suppressed with diffuse scattering. An alternative explanation for the Lorentz factor is presented that is more general and based on the capture volume in diffraction space. This theory, when applied to the scattering from powders, will evaluate the full scattering profile, including peak widths and the `background'. The theory should provide an increased understanding of the reliability of powder diffraction measurements, and may also have wider implications for the analysis of powder diffraction data, by increasing the accuracy of intensities predicted from structural models.

  5. Minimizing Head Acceleration in Soccer: A Review of the Literature.

    PubMed

    Caccese, Jaclyn B; Kaminski, Thomas W

    2016-11-01

    Physicians and healthcare professionals are often asked for recommendations on how to keep athletes safe during contact sports such as soccer. With an increase in concussion awareness and concern about repetitive subconcussion, many parents and athletes are interested in mitigating head acceleration in soccer, so we conducted a literature review on factors that affect head acceleration in soccer. We searched electronic databases and reference lists to find studies using the keywords 'soccer' OR 'football' AND 'head acceleration'. Because of a lack of current research in soccer heading biomechanics, this review was limited to 18 original research studies. Low head-neck segment mass predisposes athletes to high head acceleration, but head-neck-torso alignment during heading and follow-through after contact can be used to decrease head acceleration. Additionally, improvements in symmetric neck flexor and extensor strength and neuromuscular neck stiffness can decrease head acceleration. Head-to-head impacts and unanticipated ball contacts result in the highest head acceleration. Ball contacts at high velocity may also be dangerous. The risk of concussive impacts may be lessened through the use of headgear, but headgear may also cause athletes to play more recklessly because they feel a sense of increased security. Young, but physically capable, athletes should be taught proper heading technique in a controlled setting, using a carefully planned progression of the skill.

  6. Treatment vault shielding for a flattening filter-free medical linear accelerator

    NASA Astrophysics Data System (ADS)

    Kry, Stephen F.; Howell, Rebecca M.; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N.

    2009-03-01

    The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m3 less concrete to shield the single-energy linac and 36 m3 less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.

  7. Treatment vault shielding for a flattening filter-free medical linear accelerator.

    PubMed

    Kry, Stephen F; Howell, Rebecca M; Polf, Jerimy; Mohan, Radhe; Vassiliev, Oleg N

    2009-03-07

    The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target current requirements were determined from treatment planning studies of several disease sites with, and without, the flattening filter. The flattened beam shielding data were compared to data published in NCRP Report No. 151, and the unflattened beam shielding data were presented relative to the NCRP data. Finally, the shielding requirements for a typical treatment vault were determined for a single-energy (6 MV) linac and a dual-energy (6 MV/18 MV) linac. With the exception of large-angle patient scatter fractions and wall scatter fractions, the vault shielding parameters were reduced when the flattening filter was removed. Much of this reduction was consistent with the reduced average energy of the FFF beams. Primary beam TVLs were reduced by 12%, on average, and small-angle scatter fractions were reduced by up to 30%. Head leakage was markedly reduced because less integral target current was required to deliver the target dose. For the treatment vault examined in the current study, removal of the flattening filter reduced the required thickness of the primary and secondary barriers by 10-20%, corresponding to 18 m(3) less concrete to shield the single-energy linac and 36 m(3) less concrete to shield the dual-energy linac. Thus, a shielding advantage was found when the linac was operated without the flattening filter. This translates into a reduction in occupational exposure and/or the cost and space of shielding.

  8. An evaluation to design high performance pinhole array detector module for four head SPECT: a simulation study

    NASA Astrophysics Data System (ADS)

    Rahman, Tasneem; Tahtali, Murat; Pickering, Mark R.

    2014-09-01

    The purpose of this study is to derive optimized parameters for a detector module employing an off-the-shelf X-ray camera and a pinhole array collimator applicable for a range of different SPECT systems. Monte Carlo simulations using the Geant4 application for tomographic emission (GATE) were performed to estimate the performance of the pinhole array collimators and were compared to that of low energy high resolution (LEHR) parallel-hole collimator in a four head SPECT system. A detector module was simulated to have 48 mm by 48 mm active area along with 1mm, 1.6mm and 2 mm pinhole aperture sizes at 0.48 mm pitch on a tungsten plate. Perpendicular lead septa were employed to verify overlapping and non-overlapping projections against a proper acceptance angle without lead septa. A uniform shape cylindrical water phantom was used to evaluate the performance of the proposed four head SPECT system of the pinhole array detector module. For each head, 100 pinhole configurations were evaluated based on sensitivity and detection efficiency for 140 keV γ-rays, and compared to LEHR parallel-hole collimator. SPECT images were reconstructed based on filtered back projection (FBP) algorithm where neither scatter nor attenuation corrections were performed. A better reconstruction algorithm development for this specific system is in progress. Nevertheless, activity distribution was well visualized using the backprojection algorithm. In this study, we have evaluated several quantitative and comparative analyses for a pinhole array imaging system providing high detection efficiency and better system sensitivity over a large FOV, comparing to the conventional four head SPECT system. The proposed detector module is expected to provide improved performance in various SPECT imaging.

  9. Retrieval analysis of titanium nitride (TiN) coated prosthetic femoral heads articulating with polyethylene.

    PubMed

    Łapaj, Łukasz; Wendland, Justyna; Markuszewski, Jacek; Mróz, Adrian; Wiśniewski, Tomasz

    2015-03-01

    Data regarding in vivo performance of titanium nitride (TiN) coated prosthetic femoral heads is scarce, and available studies of older generations of implants demonstrated coating wear in vivo. That is why we conducted a retrieval analysis of 11 femoral heads (articulating in vivo for 1-56 months) with TiN film formed using physical vapor deposition (PVD), to verify if coating failure is a problem in contemporary implants. Retrieved implants were examined using scanning electron microscope, coating roughness was evaluated with a contact profilometer and adhesion was tested using a Rockwell HRC test according to VDI 3824 guideline. Although no gross failure of the TiN coating was observed in our retrievals, all implants had defects typical for PVD coatings, such as pinholes, small titanium droplets and blisters with delaminated coating. In some heads the coating was contaminated with small niobium (Nb) droplets uniformly scattered on the entire surface of the film. Presence of Nb contamination was associated with an increased number and area of other types of defects and poorer coating adhesion. In one component, subjected to multiple dislocations we found severe delamination and cracking of the coating, increased roughness and the presence of third bodies. Our results indicate, that although wear of the coating is lower than seen in older generations of implants, inconsistent quality of the TiN film among different implants indicates the need for strict monitoring of the manufacturing process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Accurate optimization of amino acid form factors for computing small-angle X-ray scattering intensity of atomistic protein structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tong, Dudu; Yang, Sichun; Lu, Lanyuan

    2016-06-20

    Structure modellingviasmall-angle X-ray scattering (SAXS) data generally requires intensive computations of scattering intensity from any given biomolecular structure, where the accurate evaluation of SAXS profiles using coarse-grained (CG) methods is vital to improve computational efficiency. To date, most CG SAXS computing methods have been based on a single-bead-per-residue approximation but have neglected structural correlations between amino acids. To improve the accuracy of scattering calculations, accurate CG form factors of amino acids are now derived using a rigorous optimization strategy, termed electron-density matching (EDM), to best fit electron-density distributions of protein structures. This EDM method is compared with and tested againstmore » other CG SAXS computing methods, and the resulting CG SAXS profiles from EDM agree better with all-atom theoretical SAXS data. By including the protein hydration shell represented by explicit CG water molecules and the correction of protein excluded volume, the developed CG form factors also reproduce the selected experimental SAXS profiles with very small deviations. Taken together, these EDM-derived CG form factors present an accurate and efficient computational approach for SAXS computing, especially when higher molecular details (represented by theqrange of the SAXS data) become necessary for effective structure modelling.« less

  11. Re-irradiation for head and neck squamous cell carcinoma.

    PubMed

    Benson, Rony; Giridhar, Prashant; Venkatesulu, Bhanu Prasad; Mallick, Supriya; Raza, Mohd Waseem; Rath, Goura Kishor

    2017-03-01

    Local recurrences after curative treatment have a potential for cure with salvage surgery or with re-irradiation. We reviewed the PubMed for articles published in English with key words squamous cell carcinoma, recurrent, re-irradiation, prognostic factors to find relevant articles describing prognostic factors, re-irradiation, and outcome for recurrent head and neck squamous cell carcinoma. Various factors including age, performance status, time for recurrence, previous radiation dose volume and site of recurrence, previous use of chemotherapy are all prognostic factors in recurrent head and neck squamous cell carcinoma. Surgery is feasible in very select subgroup of patients and must be done when feasible. Re-irradiation with the aid of modern sophisticated technology is safe and confers durable and clinically meaningful survival benefit. Re-irradiation in head and neck recurrent squamous cell carcinoma may provide an expected median survival of 10-12months. Chemotherapy may be added along with radiation in the recurrent setting. Treatment approaches may have to be personalized. Re surgery must be done in all patients in whom it is feasible. In patients in whom surgery is not feasible, re-irradiation must be evaluated as a therapeutic option especially in patients with limited volume recurrence. Copyright © 2016 National Cancer Institute, Cairo University. Production and hosting by Elsevier B.V. All rights reserved.

  12. Incidence and Risk Factors of Refeeding Syndrome in Head and Neck Cancer Patients-An Observational Study.

    PubMed

    Rasmussen, Stine Ostenfeldt; Kristensen, Marianne Boll; Wessel, Irene; Andersen, Jens Rikardt

    2016-01-01

    This study aimed to determine the incidence rates of refeeding phenomena (defined as a decline in p-phosphate) and refeeding syndrome (RFS; defined as development of clinical symptoms in addition to a decline in p-phosphate) in head and neck cancer patients, and to identify risk factors. Fifty-four head and neck cancer patients referred for surgery were included. Forty-six potential risk factors were registered at the baseline, and p-phosphate was measured at Days 2, 4, and 7. Eleven patients (20%) developed RFS, and twenty-eight (52%) developed refeeding phenomena. At baseline, these patients presented a higher prevalence of head and neck pain, eating difficulties, higher p-phosphate levels, lower p-transferrin levels, and, in men, lower b-hemoglobin levels. Patients who developed symptoms had a decline in p-phosphate ≥0.22 mmol/l. At baseline, these patients had higher p-phosphate levels, higher alcohol consumption, and lower p-transferrin and p-sodium levels, as well as a higher prevalence of eating difficulties, low handgrip strength (HGS), and a history of radiation therapy. The risk factors most strongly associated with the development of refeeding phenomena and RFS were pain, eating difficulties, low HGS, high alcohol intake, and previous radiation therapy.

  13. Distribution of stromal cell-derived factor-1 genetic polymorphism in head and neck cancer patients of Indonesian population

    NASA Astrophysics Data System (ADS)

    Sabrina, H.; Midoen, Y. H.; Soedarsono, N.; Djamal, N. Z.; Suhartono, A. W.; Auerkari, E. I.

    2018-05-01

    Head and neck cancer (HNC), the fourth most common cancer in Indonesia, is associated with several risk factors, including genetic ones. The chemokine Stromal Cell-Derived Factor-1 (SDF-1) contributes to tumor growth, angiogenesis, and metastasis of cancer. Recent studies suggest the G801A genetic polymorphism of SDF-1 as a factor increasing susceptibility to HNC. The aim of this study was to investigate whether the G801A polymorphism of SDF-1 is associated with the susceptibility of HNC in the Indonesian population. Samples from 50 head and neck cancer patients and 50 healthy controls were genotyped by PCR-RFLP method. The distributions of genotypes and alleles were analyzed for the Hardy-Weinberg Equilibrium (HWE) and for the potential association with the head and neck cancer susceptibility by Fisher’s exact test. The study showed no statistically significant difference in the frequencies of SDF-1 G801A polymorphism between the control and case groups. The homozygous variant genotype occurred at low frequency in both cancer and control groups, while the wild type was not less common in the cancer group than in the control group. Unlike in some studies on other Asian populations, the polymorphism was not found to be significantly associated with HNC susceptibility in the Indonesian population.

  14. Evaluation of detector readout gain mode and bowtie filters for cone-beam CT imaging of the head

    NASA Astrophysics Data System (ADS)

    Xu, Jennifer; Sisniega, Alejandro; Zbijewski, Wojciech; Dang, Hao; Webster Stayman, J.; Wang, Xiaohui; Foos, David H.; Aygun, Nafi; Koliatsos, Vassillis E.; Siewerdsen, Jeffrey H.

    2016-08-01

    The effects of detector readout gain mode and bowtie filters on cone-beam CT (CBCT) image quality and dose were characterized for a new CBCT system developed for point-of-care imaging of the head, with potential application to diagnosis of traumatic brain injury, intracranial hemorrhage (ICH), and stroke. A detector performance model was extended to include the effects of detector readout gain on electronic digitization noise. The noise performance for high-gain (HG), low-gain (LG), and dual-gain (DG) detector readout was evaluated, and the benefit associated with HG mode in regions free from detector saturation was quantified. Such benefit could be realized (without detector saturation) either via DG mode or by incorporation of a bowtie filter. Therefore, three bowtie filters were investigated that varied in thickness and curvature. A polyenergetic gain correction method was developed to equalize the detector response between the flood-field and projection data in the presence of a bowtie. The effect of bowtie filters on dose, scatter-to-primary ratio, contrast, and noise was quantified in phantom studies, and results were compared to a high-speed Monte Carlo (MC) simulation to characterize x-ray scatter and dose distributions in the head. Imaging in DG mode improved the contrast-to-noise ratio (CNR) by ~15% compared to LG mode at a dose (D 0, measured at the center of a 16 cm CTDI phantom) of 19 mGy. MC dose calculations agreed with CTDI measurements and showed that bowtie filters reduce peripheral dose by as much as 50% at the same central dose. Bowtie filters were found to increase the CNR per unit square-root dose near the center of the image by ~5-20% depending on bowtie thickness, but reduced CNR in the periphery by ~10-40%. Images acquired at equal CTDIw with and without a bowtie demonstrated a 24% increase in CNR at the center of an anthropomorphic head phantom. Combining a thick bowtie filter with a short arc (180°  +  fan angle) scan centered on the posterior of the head reduced dose to the eye lens by up to 90%. Acquisition in DG mode (without a bowtie filter) was beneficial to the detection of small, low contrast lesions (e.g. subtle ICH) in CBCT. While bowtie filters were found to reduce dose, mitigate sensor saturation at the periphery in HG mode, and improve CNR at the center of the image, the image quality at the periphery was slightly reduced compared to DG mode, and the use of a bowtie required careful implementation of the polyenergetic flood-field correction to avoid artifacts.

  15. Evaluation of detector readout gain mode and bowtie filters for cone-beam CT imaging of the head.

    PubMed

    Xu, Jennifer; Sisniega, Alejandro; Zbijewski, Wojciech; Dang, Hao; Stayman, J Webster; Wang, Xiaohui; Foos, David H; Aygun, Nafi; Koliatsos, Vassillis E; Siewerdsen, Jeffrey H

    2016-08-21

    The effects of detector readout gain mode and bowtie filters on cone-beam CT (CBCT) image quality and dose were characterized for a new CBCT system developed for point-of-care imaging of the head, with potential application to diagnosis of traumatic brain injury, intracranial hemorrhage (ICH), and stroke. A detector performance model was extended to include the effects of detector readout gain on electronic digitization noise. The noise performance for high-gain (HG), low-gain (LG), and dual-gain (DG) detector readout was evaluated, and the benefit associated with HG mode in regions free from detector saturation was quantified. Such benefit could be realized (without detector saturation) either via DG mode or by incorporation of a bowtie filter. Therefore, three bowtie filters were investigated that varied in thickness and curvature. A polyenergetic gain correction method was developed to equalize the detector response between the flood-field and projection data in the presence of a bowtie. The effect of bowtie filters on dose, scatter-to-primary ratio, contrast, and noise was quantified in phantom studies, and results were compared to a high-speed Monte Carlo (MC) simulation to characterize x-ray scatter and dose distributions in the head. Imaging in DG mode improved the contrast-to-noise ratio (CNR) by ~15% compared to LG mode at a dose (D 0, measured at the center of a 16 cm CTDI phantom) of 19 mGy. MC dose calculations agreed with CTDI measurements and showed that bowtie filters reduce peripheral dose by as much as 50% at the same central dose. Bowtie filters were found to increase the CNR per unit square-root dose near the center of the image by ~5-20% depending on bowtie thickness, but reduced CNR in the periphery by ~10-40%. Images acquired at equal CTDIw with and without a bowtie demonstrated a 24% increase in CNR at the center of an anthropomorphic head phantom. Combining a thick bowtie filter with a short arc (180°  +  fan angle) scan centered on the posterior of the head reduced dose to the eye lens by up to 90%. Acquisition in DG mode (without a bowtie filter) was beneficial to the detection of small, low contrast lesions (e.g. subtle ICH) in CBCT. While bowtie filters were found to reduce dose, mitigate sensor saturation at the periphery in HG mode, and improve CNR at the center of the image, the image quality at the periphery was slightly reduced compared to DG mode, and the use of a bowtie required careful implementation of the polyenergetic flood-field correction to avoid artifacts.

  16. Process Research on Polycrystalline Silicon Material (PROPSM)

    NASA Technical Reports Server (NTRS)

    Culik, J. S.

    1983-01-01

    The performance limiting mechanisms in large grain (greater than 1-2 mm in diameter) polycrystalline silicon was investigated by measuring the illuminated current voltage (I-V) characteristics of the minicell wafer set. The average short circuit current on different wafers is 3 to 14 percent lower than that of single crystal Czochralski silicon. The scatter was typically less than 3 percent. The average open circuit voltage is 20 to 60 mV less than that of single crystal silicon. The scatter in the open circuit voltage of most of the polycrystalline silicon wafers was 15 to 20 mV, although two wafers had significantly greater scatter than this value. The fill factor of both polycrystalline and single crystal silicon cells was typically in the range of 60 to 70 percent; however several polycrystalline silicon wafers have fill factor averages which are somewhat lower and have a significantly larger degree of scatter.

  17. Neutron Scattering Reference

    Science.gov Websites

    Conversion Factors Periodic Table of the Elements Chart of the Nuclides Map of the Nuclides Computer Index of (Atominstitut der Österreichischen Universitäten) Neutron Activation Table of Elements Neutron Scattering at neutronsources.org. The information contained here in the Neutron Scattering Web has been

  18. Investigation of the structure of unilamellar dimyristoylphosphatidylcholine vesicles in aqueous sucrose solutions by small-angle neutron and X-ray scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiselev, M. A., E-mail: elena@jinr.ru; Zemlyanaya, E. V.; Zhabitskaya, E. I.

    2015-01-15

    The structure of a polydispersed population of unilamellar dimyristoylphosphatidylcholine (DMPC) vesicles in sucrose solutions has been investigated by small-angle neutron scattering (SANS) and small-angle X-ray scattering (SAXS). Calculations within the model of separated form factors (SFF) show that the structure of the vesicle system depends strongly on the sucrose concentration.

  19. Early Head Growth: Relation with IQ at 8 Years and Determinants in Term Infants of Low and Appropriate Birthweight

    ERIC Educational Resources Information Center

    Lira, Pedro I. C.; Eickmann, Sophie H.; Lima, Marilia C.; Amorim, Rosemary J.; Emond, Alan M.; Ashworth, Ann

    2010-01-01

    Aim: To investigate the relation between head growth at different periods and IQ at 8 years, and to identify factors associated with more rapid head growth. Method: Two parallel cohorts of term low birthweight (LBW) and appropriate birthweight (ABW) infants were enrolled at birth in northeast Brazil. Anthropometric measurements were made at birth,…

  20. Scattering from randomly oriented scatterers of arbitrary shape in the low-frequency limit with application to vegetation

    NASA Technical Reports Server (NTRS)

    Karam, M. A.; Fung, A. K.

    1983-01-01

    A general theory of intensity scattering from small particles of arbitrary shape has been developed based on the radiative transfer theory. Upon permitting the particles to orient in accordance with any prescribed distribution, scattering models can be derived. By making an appropriate choice of the particle size, the scattering model may be used to estimate scattering from media such as snow, vegetation and sea ice. For the purpose of illustration only comparisons with measurements from a vegetated medium are shown. The difference in scattering between elliptic- and circular-shaped leaves is demonstrated. In the low-frequency limit, the major factors on backscattering from vegetation are found to be the depth of the vegetation layer and the orientation distribution of the leaves. The shape of the leaf is of secondary importance.

  1. Scattering from randomly oriented scatterers of arbitrary shape in the low-frequency limit with application to vegetation

    NASA Technical Reports Server (NTRS)

    Karam, M. A.; Fung, A. K.

    1984-01-01

    A general theory of intensity scattering from small particles of arbitrary shape was developed based on the radiative transfer theory. Upon permitting the particles to orient in accordance with any prescribed distribution, scattering models can be derived. By making an appropriate choice of the particle size, the scattering model may be used to estimate scattering from media such as snow, vegetation and sea ice. For the purpose of illustration only comparisons with measurements from a vegetated medium are shown. The difference in scattering between elliptic and circular shaped leaves is demonstrated. In the low frequency limit, the major factors on backscattering from vegetation are found to be the depth of the vegetation layer and the orientation distribution of the leaves. The shape of the leaf is of secondary importance.

  2. The neurobehavioural rating scale: assessment of the behavioural sequelae of head injury by the clinician.

    PubMed Central

    Levin, H S; High, W M; Goethe, K E; Sisson, R A; Overall, J E; Rhoades, H M; Eisenberg, H M; Kalisky, Z; Gary, H E

    1987-01-01

    To investigate the inter-rater reliability and validity of the Neurobehavioural Rating Scale at various stages of recovery after hospitalisation for closed head injury, we studied 101 head trauma patients who had no antecedent neuropsychiatric disorder. The results demonstrated satisfactory inter-rater reliability and showed that the Neurobehavioural Rating Scale reflects both the severity and chronicity of closed head injury. A principal components analysis revealed four factors which were differentially related to severity of head injury and the presence of a frontal lobe mass lesion. Although our findings provide support for utilising clinical ratings of behaviour to investigate sequelae of head injury, extension of this technique to other settings is necessary to evaluate the distinctiveness of the neurobehavioural profile of closed head injury as compared with other aetiologies of brain damage. PMID:3572433

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsytovich, Vadim, E-mail: tsytov@lpi.ru; Max Planck Institute for Extraterrestrial Physics, Garching; Gusein-zade, Namik

    Dust structuring is a natural and universal process in complex plasmas. The scattering of electromagnetic waves by dust structures is governed by the factor of coherency, i.e., the total number of coherent electrons in a single structure. In the present paper, we consider how the factor of coherency changes due to additional pulse electron heating and show that it obeys a hysteresis. After the end of the pulse heating, the scattering intensity differs substantially from that before heating. There are three necessary conditions for scattering hysteresis: first, the radiation wavelength should be larger than the pattern (structure) size; second, themore » total number of coherent electrons confined by the structure should be large; and third, the heating pulse duration should be shorter than the characteristic time of dust structure formation. We present the results of numerical calculations using existing models of self-consistent dust structures with either positively or negatively charged dust grains. It is shown that, depending on the grain charge and the ionization rate, two types of hysteresis are possible: one with a final increase of the scattering and the other with a final decrease of the scattering. It is suggested that the hysteresis of coherent scattering can be used as a tool in laboratory experiments and that it can be a basic mechanism explaining the observed hysteresis in radar scattering by noctilucent clouds during active experiments on electron heating in mesosphere.« less

  4. [Spectrum simulation based on data derived from red tide].

    PubMed

    Liu, Zhen-Yu; Cui, Ting-Wei; Yue, Jie; Jiang, Tao; Cao, Wen-Xi; Ma, Yi

    2011-11-01

    The present paper utilizes the absorption data of red tide water measured during the growing and dying course to retrieve imaginary part of the index of refraction based on Mie theory, carries out the simulation and analysis of average absorption efficiency factors, average backscattering efficiency factors and scattering phase function. The analysis of the simulation shows that Mie theory can be used to reproduce the absorption property of Chaetoceros socialis with an average error of 11%; the average backscattering efficiency factors depend on the value of absorption whose maximum value corresponds to the wavelength range from 400 to 700 nanometer; the average backscattering efficiency factors showed a maximum value on 17th with a low value during the outbreak of red tide and the minimum on 21th; the total scattering, weakly depending on the absorption, is proportional to the size parameters which represent the relative size of cell diameter with respect to the wavelength, while the angle scattering intensity is inversely proportional to wavelength.

  5. Experience of head and neck theatre staff and attitudes to human factors using an aviation-based analysis and classification system--a pilot survey.

    PubMed

    Konieczny, Katarzyna M; Seager, Leonie; Scott, Jim; Colbert, Serryth; Dale, Trevor; Brennan, Peter A

    2014-01-01

    The role that human factors have in contributing to air crashes is well known and is included as an essential part of training. Awareness of human factors in surgery is increasingly being recognised but surprisingly few papers have come from head and neck specialties. We circulated a questionnaire on human factors based on an aviation model to 140 head and neck medical and ancillary staff who work in operating theatres in 3 large UK hospitals. Most positive responses were found in the consultant group followed by trainee doctors and support staff. A significant difference was found in the subcategories of Unsafe Supervision (p=0.002) and Preconditions to Unsafe Acts (p=0.001). This work will help to identify multi-system deficiencies that can be corrected, and highlights aspects that may yield the greatest reduction in surgical errors. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Prediction of Future Epilepsy in Neonates With Hypoxic-Ischemic Encephalopathy Who Received Selective Head Cooling.

    PubMed

    McDonough, Tiffani L; Paolicchi, Juliann M; Heier, Linda A; Das, Nikkan; Engel, Murray; Perlman, Jeffrey M; Grinspan, Zachary M

    2017-06-01

    Epilepsy outcomes after therapeutic hypothermia for neonates with hypoxic-ischemic encephalopathy are understudied. The authors used multivariable logistic regression to predict epilepsy in neonates after selective head cooling. Sensitivity analyses used magnetic resonance imaging (MRI) and electroencephalogram (EEG) interpretations by different clinicians. Fifty neonates had 2-year follow-up. Nine developed epilepsy. Predictors included pH ≤6.8 on day of birth (adjusted odds ratio [OR] 19 [95% confidence interval (CI) 1-371]), burst suppression on EEG on day 4 (8.2 [1.3-59]), and MRI deep gray matter injury (OR 33 [2.4-460]). These factors stratify neonates into low (0-1 factors; 3% [0%-14%] risk), medium (2 factors; 56% [21%-86%] risk), and high-risk groups (3 factors; 100% [29%-100%] risk) for epilepsy. The stratification was robust to varying clinical interpretations of the MRI and EEG. Neonates with hypoxic-ischemic encephalopathy who undergo selective head cooling appear at risk of epilepsy if they have 2 to 3 identified factors. If validated, this rule may help counsel families and identify children for close clinical follow-up.

  7. SU-E-T-168: Characterization of Neutrons From the TrueBeam Treatment Head

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawkey, D; Svatos, M

    2015-06-15

    Purpose: Calculate neutron production and transport in the TrueBeam treatment head, as input for vault design and phantom dose calculations. Methods: A detailed model of the treatment head, including shielding components off the beam axis, was created from manufacturer’s engineering drawings. Simulations were done with Geant4 for the 18X, 15X, 10X and 10FFF beams, tuned to match measured dose distributions inside the treatment field. Particles were recorded on a 70 cm radius sphere surrounding the treatment head enabling input into simulations of vaults. Results: For the 18X beam, 11×10{sup 9} neutrons/MU were observed. The energy spectrum was a broad peakmore » with average energy 0.37 MeV. With jaws closed, 48% of the neutrons were generated in the primary collimator, 18% in the jaws, 12% in the target, and 10% in the flattening filter. With wide open jaws, few neutrons were produced in the jaws and consequently total neutron production dropped to 8.5×10{sup 9} neutrons/MU. Angular distributions were greatest along the beam axis (12×10{sup 9} neutrons/MU/sr, within 2 deg of the beam axis) and antiparallel to the beam axis (7×10{sup 9} neutrons/MU/sr). Peaks were observed in the neutron energy spectrum, corresponding to elastic scattering resonances in the shielding materials. Neutron production was lower for the other beams studied: 4.1×10{sup 9} neutrons/MU for 15X, 0.38×10{sup 9} neutrons/MU for 10X, and 0.22×10{sup 9} neutrons/MU for 10FFF. Despite dissimilar treatment head geometries and materials, the neutron production and energy spectrum were similar to those reported for Clinac accelerators. Conclusion: Detailed neutron production and leakage calculations for the TrueBeam treatment head were done. Unlike other studies, results are independent of the surrounding vault, enabling vault design calculations.« less

  8. Pyridine-pyrimidine amides that prevent HGF-induced epithelial scattering by two distinct mechanisms.

    PubMed

    Siddiqui-Jain, Adam; Hoj, Jacob P; Hargiss, J Blade; Hoj, Taylor H; Payne, Carter J; Ritchie, Collin A; Herron, Steven R; Quinn, Colette; Schuler, Jeffrey T; Hansen, Marc D H

    2017-09-01

    Stimulation of cultured epithelial cells with scatter factor/hepatocyte growth factor (HGF) results in individual cells detaching and assuming a migratory and invasive phenotype. Epithelial scattering recapitulates cancer progression and studies have implicated HGF signaling as a driver of cancer metastasis. Inhibitors of HGF signaling have been proposed to act as anti-cancer agents. We previously screened a small molecule library for compounds that block HGF-induced epithelial scattering. Most hits identified in this screen exhibit anti-mitotic properties. Here we assess the biological mechanism of a compound that blocks HGF-induced scattering with limited anti-mitotic activity. Analogs of this compound have one of two distinct activities: inhibiting either cell migration or cell proliferation with cell cycle arrest in G2/M. Each activity bears unique structure-activity relationships. The mechanism of action of anti-mitotic compounds is by inhibition of microtubule polymerization; these compounds entropically and enthalpically bind tubulin in the colchicine binding site, generating a conformational change in the tubulin dimer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. The effect of kinematic parameters on inelastic scattering of glyoxal.

    PubMed

    Duca, Mariana D

    2004-10-08

    The effect of kinematic parameters (relative velocity v(rel), relative momentum p(rel), and relative energy E(rel)) on the rotational and rovibrational inelastic scatterings of 0(0)K(0)S(1) trans-glyoxal has been investigated by colliding glyoxal seeded in He or Ar with target gases D2, He, or Ne at different scattering angles in crossed supersonic beams. The inelastic spectra for target gases He and D2 acquired with two different sets of kinematic parameters revealed no significant differences. This result shows that kinematic factors have the major influence in the inelastic scattering channel competition whereas the intermolecular potential energy surface plays only a secondary role. The well-defined exponential dependence of relative cross sections on exchanged angular momentum identifies angular momentum as the dominant kinematic factor in collision-induced rotationally and rovibrationally inelastic scatterings. This is supported by the behavior of the relative inelastic cross sections data in a "slope-p(rel)" representation. In this form, the data show a trend nearly independent of the target gas identity. Representations involving E(rel) and v(rel) show trends specific to the target gas.

  10. Determination of the structure of subsurface layers by means of coaxial time-of-flight scattering and recoiling spectrometry (TOF-SARS)

    NASA Astrophysics Data System (ADS)

    Wang, Y.; Teplov, S. V.; Rabalais, J. W.

    1994-05-01

    It is demonstrated that both surface and subsurface structural information can be obtained from Si{100}-(2 × 1) and Si{100}-(1 × 1)-H by coupling coaxial time-of-flight scattering and recoiling spectrometry (TOF-SARS) with three-dimensional trajectory simulations. Experimentally, backscattering intensity versus incident α angle scans at a scattering angle of ˜ 180° have been measured for 2 keV He + incident on both the (2 × 1) and (1 × 1)-H surfaces. Computationally, an efficient three-dimensional version of the Monte Carlo computer code RECAD has been developed and applied to simulation of the TOF-SARS results. An R (reliability) factor has been introduced for quantitative evaluation of the agreement between experimental and simulated scans. For the case of 2 keV He + scattering from Si{100}, scattering features can be observed and delineated from as many as 14 atomic layers ( ˜ 18 Å) below the surface. The intradimer spacing D is determined as 2.2 Å from the minimum in the R-factor versus D plot.

  11. Dispersive analysis of the pion transition form factor

    NASA Astrophysics Data System (ADS)

    Hoferichter, M.; Kubis, B.; Leupold, S.; Niecknig, F.; Schneider, S. P.

    2014-11-01

    We analyze the pion transition form factor using dispersion theory. We calculate the singly-virtual form factor in the time-like region based on data for the cross section, generalizing previous studies on decays and scattering, and verify our result by comparing to data. We perform the analytic continuation to the space-like region, predicting the poorly-constrained space-like transition form factor below , and extract the slope of the form factor at vanishing momentum transfer . We derive the dispersive formalism necessary for the extension of these results to the doubly-virtual case, as required for the pion-pole contribution to hadronic light-by-light scattering in the anomalous magnetic moment of the muon.

  12. Ab initio simulations of the dynamic ion structure factor of warm dense lithium

    DOE PAGES

    Witte, B. B. L.; Shihab, M.; Glenzer, S. H.; ...

    2017-04-06

    Here, we present molecular dynamics simulations based on finite-temperature density functional theory that determine self-consistently the dynamic ion structure factor and the electronic form factor in lithium. Our comprehensive data set allows for the calculation of the dispersion relation for collective excitations, the calculation of the sound velocity, and the determination of the ion feature from the total electronic form factor and the ion structure factor. The results are compared with available experimental x-ray and neutron scattering data. Good agreement is found for both the liquid metal and warm dense matter domain. Finally, we study the impact of possible targetmore » inhomogeneities on x-ray scattering spectra.« less

  13. Ab initio simulations of the dynamic ion structure factor of warm dense lithium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Witte, B. B. L.; Shihab, M.; Glenzer, S. H.

    Here, we present molecular dynamics simulations based on finite-temperature density functional theory that determine self-consistently the dynamic ion structure factor and the electronic form factor in lithium. Our comprehensive data set allows for the calculation of the dispersion relation for collective excitations, the calculation of the sound velocity, and the determination of the ion feature from the total electronic form factor and the ion structure factor. The results are compared with available experimental x-ray and neutron scattering data. Good agreement is found for both the liquid metal and warm dense matter domain. Finally, we study the impact of possible targetmore » inhomogeneities on x-ray scattering spectra.« less

  14. Comparative study of inelastic squared form factors of the vibronic states of B 1Σu+ , C 1Πu , and E F 1Σg+ for molecular hydrogen: Inelastic x-ray and electron scattering

    NASA Astrophysics Data System (ADS)

    Xu, Long-Quan; Kang, Xu; Peng, Yi-Geng; Xu, Xin; Liu, Ya-Wei; Wu, Yong; Yang, Ke; Hiraoka, Nozomu; Tsuei, Ku-Ding; Wang, Jian-Guo; Zhu, Lin-Fan

    2018-03-01

    A joint experimental and theoretical investigation of the valence-shell excitations of hydrogen has been performed by the high-resolution inelastic x-ray scattering and electron scattering as well as the multireference single- and double-excitation configuration-interaction method. Momentum-transfer-dependent inelastic squared form factors for the vibronic series belonging to the B 1Σu+ ,C 1Πu , and E F 1Σg+ electronic states of molecular hydrogen have been derived from the inelastic x-ray scattering method at an impact photon energy around 10 keV, and the electron energy-loss spectra measured at an incident electron energy of 1500 eV. It is found that both the present and the previous calculations cannot satisfactorily reproduce the inelastic squared form-factor profiles for the higher vibronic transitions of the B 1Σu+ state of molecular hydrogen, which may be due to the electronic-vibrational coupling for the higher vibronic states. For the C 1Πu state and some vibronic excitations of E F 1Σg+ state, the present experimental results are in good agreement with the present and previous calculations, while the slight differences between the inelastic x-ray scattering and electron energy-loss spectroscopy results in the larger squared momentum-transfer region may be attributed to the increasing role of the higher-order Born terms in the electron-scattering process.

  15. A symmetrical subtraction combined with interpolated values for eliminating scattering from fluorescence EEM data.

    PubMed

    Xu, Jing; Liu, Xiaofei; Wang, Yutian

    2016-08-05

    Parallel factor analysis is a widely used method to extract qualitative and quantitative information of the analyte of interest from fluorescence emission-excitation matrix containing unknown components. Big amplitude of scattering will influence the results of parallel factor analysis. Many methods of eliminating scattering have been proposed. Each of these methods has its advantages and disadvantages. The combination of symmetrical subtraction and interpolated values has been discussed. The combination refers to both the combination of results and the combination of methods. Nine methods were used for comparison. The results show the combination of results can make a better concentration prediction for all the components. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Evaluation of risk factors and development of acute kidney injury in aneurysmal subarachnoid hemorrhage, head injury, and severe sepsis/septic shock patients during ICU treatment.

    PubMed

    Kamar, Ceren; Ali, Achmet; Altun, Demet; Orhun, Günseli; Sabancı, Akın; Sencer, Altay; Akıncı, İbrahim Özkan

    2017-01-01

    There are few studies examining development of acute kidney injury (AKI) in the various types of patients in intensive care units (ICUs). Presently described is evaluation of risk factors and development of AKI in different groups of ICU patients. Present study was performed in 3 different ICUs. Development of AKI was measured using Acute Kidney Injury Network (AKIN) classification system. Total of 300 patients who were treated in trauma, neurosurgery, or general ICU departments (due to head injury, aneurysmal subarachnoid hemorrhage [aSAH], or severe sepsis/septic shock, respectively) were assessed for incidence, risk factors, and development of AKI. AKI did not develop in aSAH patients when evaluated based on serum creatinine level; however, it was observed in 5% of aSAH patients according to volume adjusted creatinine (VACr) level. AKI developed in 76% of sepsis group, and in 20% of head injury group, based on AKIN classification, according to both serum and VACr levels. Incidence of AKI was significantly higher in sepsis group (p<0.001). Only use of vasopressor was significantly related to AKI development in sepsis and head injury groups. Mortality rate was 8%, 22%, and 42% in aSAH, head injury, and sepsis groups, respectively. AKI development and vasopressor use were significantly related to mortality in sepsis group. Despite similar characteristics and risk factors, there were fewer instances of AKI in aSAH group. Hypertension or hydration therapy used to treat vasospasm and polyuria due to cerebral salt-wasting syndrome may prevent aSAH patients from developing AKI.

  17. War and disaster in Sri Lanka: Depression, family adjustment and health among women heading households.

    PubMed

    Banford Witting, Alyssa; Lambert, Jessica; Wickrama, Thulitha; Thanigaseelan, Sivaguru; Merten, Michael

    2016-08-01

    The civil war, lasting from 1983 to 2009, and the tsunami that struck Southeastern Asia in 2004 were major stressors that changed the demographic landscape of the northern province of Sri Lanka. The composition of families changed dramatically, with an increase in female-headed households, largely due to casualties. The conservation of resources (COR) model was applied in this study to examine relationships between risk and resiliency factors among women heading households, including women widowed by war or disaster. This study represents an investigation of the association between predictive risk and resiliency factors (i.e. war damage and loss, social support, economic status, religious participation and discrimination) and outcomes representing well-being (depressive symptoms, family adjustment and a rating of physical health). Data from 514 women heading households living in the Kilinochchi district of Sri Lanka were collected through face-to-face interviews in 2013, and associations among the data were estimated using path analysis. Results suggest that resiliency factors that are representative of greater resources generally predicted lower levels of distress and vice versa. Further study informing intervention development with women heading households in Sri Lanka is warranted to better understand which individual, family and community resources are most important to mobilize for sustainable recovery efforts to be successful in the decades following war and natural disaster. © The Author(s) 2016.

  18. Risk factors and impact of orthopaedic monitoring on the outcome of avascular necrosis of the femoral head in adults with sickle cell disease: 215 patients case study with control group.

    PubMed

    Mukisi-Mukaza, M; Saint Martin, C; Etienne-Julan, M; Donkerwolcke, M; Burny, M E; Burny, F

    2011-12-01

    Sickle cell disease is a public health problem. The WHO has recommended that global management be implemented to reduce mortality and morbidity. Since no comprehensive care programme for bone and joint complications exists, the Caribbean Sickle Cell Disease Center added orthopaedic consultation to screen for and monitor these complications in 1992. Comprehensive medical and surgical care of patients with sickle cell disease will reduce the complications and disability associated with this disease. Two populations were compared to evaluate the impact of comprehensive disease management on the occurrence of avascular necrosis (AVN) of the femoral head (femoral head AVN). The case-control series, [E-1994], included 115 patients (58 SS and 57 S) without orthopaedic monitoring and was evaluated retrospectively. The other patient series, [E-2008], included 215 patients (94 SS and 121 SC) with systematic orthopaedic care and was followed prospectively. Age, gender, duration of follow-up, haemoglobin levels, genotype, pain before treatment, associated humerus AVN and leg ulcers were analysed. Femoral head AVN occurred in young adult patients (35.3 ± 4 years for [E-1994] and 29 ± 3.4 years for [E-2008]). Only elevated haemoglobin levels were associated with the occurrence of femoral head AVN, which suggests that increased blood viscosity contributes to the condition ([E-1994], P<0.0001; [E-2008], P=0.001). Treatment in [E-2008] patients reduced the number of femoral head AVN cases from 36.5% in [E-1994] to 14.4% in [E-2008] (P<0.0001). The prevention and management of femoral head AVN must include medical treatment of the disease to reduce the occurrence of painful vaso-occlusive crises, which are known to trigger femoral head AVN. The effectiveness of this programme hinged on identifying risk factors and using simple approaches (hydration, pain medication, rest and crutches) to manage painful joint crises before femoral head AVN appeared. These approaches could be implemented in disadvantaged countries where sickle cell disease is prevalent. By knowing the risk factors, symptomatic patients who are at risk for femoral head AVN can be identified and additional evaluations can be performed early on in cases of hip pain. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  19. Applications and requirements for MEMS scanner mirrors

    NASA Astrophysics Data System (ADS)

    Wolter, Alexander; Hsu, Shu-Ting; Schenk, Harald; Lakner, Hubert K.

    2005-01-01

    Micro scanning mirrors are quite versatile MEMS devices for the deflection of a laser beam or a shaped beam from another light source. The most exciting application is certainly in laser-scanned displays. Laser television, home cinema and data projectors will display the most brilliant colors exceeding even plasma, OLED and CRT. Devices for front and rear projection will have advantages in size, weight and price. These advantages will be even more important in near-eye virtual displays like head-mounted displays or viewfinders in digital cameras and potentially in UMTS handsets. Optical pattern generation by scanning a modulated beam over an area can be used also in a number of other applications: laser printers, direct writing of photo resist for printed circuit boards or laser marking and with higher laser power laser ablation or material processing. Scanning a continuous laser beam over a printed pattern and analyzing the scattered reflection is the principle of barcode reading in 1D and 2D. This principle works also for identification of signatures, coins, bank notes, vehicles and other objects. With a focused white-light or RGB beam even full color imaging with high resolution is possible from an amazingly small device. The form factor is also very interesting for the application in endoscopes. Further applications are light curtains for intrusion control and the generation of arbitrary line patterns for triangulation. Scanning a measurement beam extends point measurements to 1D or 2D scans. Automotive LIDAR (laser RADAR) or scanning confocal microscopy are just two examples. Last but not least there is the field of beam steering. E.g. for all-optical fiber switches or positioning of read-/write heads in optical storage devices. The variety of possible applications also brings a variety of specifications. This publication discusses various applications and their requirements.

  20. Diffuse Reflectance Spectroscopy (DRS) of radiation-induced re-oxygenation in sensitive and resistant head and neck tumor xenografts

    NASA Astrophysics Data System (ADS)

    Dadgar, Sina; Rodríguez Troncoso, Joel; Rajaram, Narasimhan

    2018-02-01

    Currently, anatomical assessment of tumor volume performed several weeks after completion of treatment is the clinical standard to determine whether a cancer patient has responded to a treatment. However, functional changes within the tumor could potentially provide information regarding treatment resistance or response much earlier than anatomical changes. We have used diffuse reflectance spectroscopy to assess the short and long-term re-oxygenation kinetics of a human head and neck squamous cell carcinoma xenografts in response to radiation therapy. First, we injected UM-SCC-22B cell line into the flank of 50 mice to grow xenografts. Once the tumor volume reached 200 mm3 (designated as Day 1), the mice were distributed into radiation and control groups. Members of radiation group underwent a clinical dose of radiation of 2 Gy/day on Days 1, 4, 7, and 10 for a cumulative dose of 8 Gy. DRS spectra of these tumors were collected for 14 days during and after therapy, and the collected spectra of each tumor were converted to its optical properties using a lookup table-base inverse model. We found statistically significant differences in tumor growth rate between two groups which is in indication of the sensitivity of this cell line to radiation. We further acquired significantly different contents of hemoglobin and scattering magnitude and size in two groups. The scattering has previously been associated with necrosis. We furthermore found significantly different time-dependent changes in vascular oxygenation and tumor hemoglobin concentration in post-radiation days.

  1. Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback.

    PubMed

    Ehlers, Justis P; Srivastava, Sunil K; Feiler, Daniel; Noonan, Amanda I; Rollins, Andrew M; Tao, Yuankai K

    2014-01-01

    To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT) technology that will facilitate adoption and utilization during ophthalmic surgery. We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD) system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated.

  2. Hypothyroidism in patients treated with radiotherapy for head and neck carcinoma: standardised long-term follow-up study.

    PubMed

    Alba, J R; Basterra, J; Ferrer, J C; Santonja, F; Zapater, E

    2016-05-01

    Hypothyroidism is a common complication when radiotherapy is part of the treatment for head and neck tumours. This study aimed to show the incidence of hypothyroidism and possible risk factors in these patients. Factors related to the population, tumour, treatment and occurrence of hypothyroidism were analysed in 241 patients diagnosed with head and neck carcinoma. Approximately 53 per cent of patients were diagnosed with radiation-induced hypothyroidism. Its occurrence was related to: tumour location, laryngeal surgery type, neck dissection type, post-operative complications, cervical radiotherapy and radiotherapy unit type (linear particle accelerator or telecobalt therapy technology). Control of thyroid function should be standardised for several years after treatment, particularly in patients with risk factors, such as those treated with telecobalt therapy, those with post-operative complications and for whom the thyroid parenchyma is included in the irradiated area (laryngeal or pharyngeal location and bilateral cervical radiation).

  3. The investigation of soot and temperature distributions in a visualized direct injection diesel engine using laser diagnostics

    NASA Astrophysics Data System (ADS)

    Han, Yong-taek; Kim, Ki-bum; Lee, Ki-hyung

    2008-11-01

    Based upon the method of temperature calibration using the diffusion flame, the temperature and soot concentrations of the turbulent flame in a visualized diesel engine were qualitatively measured. Two different cylinder heads were used to investigate the effect of swirl ratio within the combustion chamber. From this experiment, we find that the highest flame temperature of the non-swirl head engine is approximately 2400 K and that of the swirl head engine is 2100 K. In addition, as the pressure of fuel injection increases, the in-cylinder temperature increases due to the improved combustion of a diesel engine. This experiment represented the soot quantity in the KL factor and revealed that the KL factor was high when the fuel collided with the cylinder wall. Moreover, the KL factor was also high in the area of the chamber where the temperature dropped rapidly.

  4. Inverse scattering transform for the time dependent Schrödinger equation with applications to the KPI equation

    NASA Astrophysics Data System (ADS)

    Zhou, Xin

    1990-03-01

    For the direct-inverse scattering transform of the time dependent Schrödinger equation, rigorous results are obtained based on an opertor-triangular-factorization approach. By viewing the equation as a first order operator equation, similar results as for the first order n x n matrix system are obtained. The nonlocal Riemann-Hilbert problem for inverse scattering is shown to have solution.

  5. Small Angle X-ray Scattering for Nanoparticle Research

    DOE PAGES

    Li, Tao; Senesi, Andrew J.; Lee, Byeongdu

    2016-04-07

    X-ray scattering is a structural characterization tool that has impacted diverse fields of study. It is unique in its ability to examine materials in real time and under realistic sample environments, enabling researchers to understand morphology at nanometer and ångström length scales using complementary small and wide angle X-ray scattering (SAXS, WAXS), respectively. Herein, we focus on the use of SAXS to examine nanoscale particulate systems. We provide a theoretical foundation for X-ray scattering, considering both form factor and structure factor, as well as the use of correlation functions, which may be used to determine a particle’s size, size distribution,more » shape, and organization into hierarchal structures. The theory is expanded upon with contemporary use cases. Both transmission and reflection (grazing incidence) geometries are addressed, as well the combination of SAXS with other X-ray and non-X ray characterization tools. Furthermore, we conclude with an examination of several key areas of research where X-rays scattering has played a pivotal role, including in situ nanoparticle synthesis, nanoparticle assembly, and in operando studies of catalysts and energy storage materials. Throughout this review we highlight the unique capabilities of X-ray scattering for structural characterization of materials in their native environment.« less

  6. Photopolarimetric properties of leaf and vegetation covers over a wide range of measurement directions

    NASA Astrophysics Data System (ADS)

    Sun, Zhongqiu; Peng, Zhiyan; Wu, Di; Lv, Yunfeng

    2018-02-01

    The optical scattering property of the target is the essential signal for passive remote sensing applications. To deepen our understanding of the light reflected from vegetation, we present results of photopolarimetric laboratory measurements from single leaf and two vegetation covers (planophile and erectophile) over a wide range of viewing directions. The bidirectional polarized reflectance factor (BPRF) was used to characterize the polarization property of our samples. We observed positive and negative polarization (-BPRFQ) of all samples in the forward scattering and backward scattering directions, respectively. Based on the comparison of the BPRF among single leaf, planophile vegetation and erectophile vegetation, our measurements demonstrate that the orientation of the leaf is a key factor in describing the amount of polarization in the forward scattering direction. Our measurements also validated certain model results stating that (1) specular reflection generates a portion of polarization in the forward scattering direction and diffuses scattering of polarized light in all hemisphere directions, (2) BPRFU is anti-symmetric in the principal plane from a recent study in which the authors simulated the polarized reflectance of vegetation cover using the vector radiative transfer theory. These photopolarimetric measurement results, which can be completely explained by the theoretical results, are useful in remote sensing applications to vegetation.

  7. Coherent and incoherent ultrasound backscatter from cell aggregates.

    PubMed

    de Monchy, Romain; Destrempes, François; Saha, Ratan K; Cloutier, Guy; Franceschini, Emilie

    2016-09-01

    The effective medium theory (EMT) was recently developed to model the ultrasound backscatter from aggregating red blood cells [Franceschini, Metzger, and Cloutier, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 58, 2668-2679 (2011)]. The EMT assumes that aggregates can be treated as homogeneous effective scatterers, which have effective properties determined by the aggregate compactness and the acoustical characteristics of the cells and the surrounding medium. In this study, the EMT is further developed to decompose the differential backscattering cross section of a single cell aggregate into coherent and incoherent components. The coherent component corresponds to the squared norm of the average scattering amplitude from the effective scatterer, and the incoherent component considers the variance of the scattering amplitude (i.e., the mean squared norm of the fluctuation of the scattering amplitude around its mean) within the effective scatterer. A theoretical expression for the incoherent component based on the structure factor is proposed and compared with another formulation based on the Gaussian direct correlation function. This theoretical improvement is assessed using computer simulations of ultrasound backscatter from aggregating cells. The consideration of the incoherent component based on the structure factor allows us to approximate the simulations satisfactorily for a product of the wavenumber times the aggregate radius kr ag around 2.

  8. Small Angle X-ray Scattering for Nanoparticle Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Tao; Senesi, Andrew J.; Lee, Byeongdu

    X-ray scattering is a structural characterization tool that has impacted diverse fields of study. It is unique in its ability to examine materials in real time and under realistic sample environments, enabling researchers to understand morphology at nanometer and ångström length scales using complementary small and wide angle X-ray scattering (SAXS, WAXS), respectively. Herein, we focus on the use of SAXS to examine nanoscale particulate systems. We provide a theoretical foundation for X-ray scattering, considering both form factor and structure factor, as well as the use of correlation functions, which may be used to determine a particle’s size, size distribution,more » shape, and organization into hierarchal structures. The theory is expanded upon with contemporary use cases. Both transmission and reflection (grazing incidence) geometries are addressed, as well the combination of SAXS with other X-ray and non-X ray characterization tools. Furthermore, we conclude with an examination of several key areas of research where X-rays scattering has played a pivotal role, including in situ nanoparticle synthesis, nanoparticle assembly, and in operando studies of catalysts and energy storage materials. Throughout this review we highlight the unique capabilities of X-ray scattering for structural characterization of materials in their native environment.« less

  9. SU-C-BRC-04: Efficient Dose Calculation Algorithm for FFF IMRT with a Simplified Bivariate Gaussian Source Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, F; Park, J; Barraclough, B

    2016-06-15

    Purpose: To develop an efficient and accurate independent dose calculation algorithm with a simplified analytical source model for the quality assurance and safe delivery of Flattening Filter Free (FFF)-IMRT on an Elekta Versa HD. Methods: The source model consisted of a point source and a 2D bivariate Gaussian source, respectively modeling the primary photons and the combined effect of head scatter, monitor chamber backscatter and collimator exchange effect. The in-air fluence was firstly calculated by back-projecting the edges of beam defining devices onto the source plane and integrating the visible source distribution. The effect of the rounded MLC leaf end,more » tongue-and-groove and interleaf transmission was taken into account in the back-projection. The in-air fluence was then modified with a fourth degree polynomial modeling the cone-shaped dose distribution of FFF beams. Planar dose distribution was obtained by convolving the in-air fluence with a dose deposition kernel (DDK) consisting of the sum of three 2D Gaussian functions. The parameters of the source model and the DDK were commissioned using measured in-air output factors (Sc) and cross beam profiles, respectively. A novel method was used to eliminate the volume averaging effect of ion chambers in determining the DDK. Planar dose distributions of five head-and-neck FFF-IMRT plans were calculated and compared against measurements performed with a 2D diode array (MapCHECK™) to validate the accuracy of the algorithm. Results: The proposed source model predicted Sc for both 6MV and 10MV with an accuracy better than 0.1%. With a stringent gamma criterion (2%/2mm/local difference), the passing rate of the FFF-IMRT dose calculation was 97.2±2.6%. Conclusion: The removal of the flattening filter represents a simplification of the head structure which allows the use of a simpler source model for very accurate dose calculation. The proposed algorithm offers an effective way to ensure the safe delivery of FFF-IMRT.« less

  10. Vacuum extraction failure is associated with a large head circumference.

    PubMed

    Kabiri, Doron; Lipschuetz, Michal; Cohen, Sarah M; Yagel, Oren; Levitt, Lorinne; Herzberg, Shmuel; Ezra, Yossef; Yagel, Simcha; Amsalem, Hagai

    2018-04-24

    To determine whether large head circumference increases the risk of vacuum extraction failure. This EMR-based study included all attempted vacuum extractions performed in a tertiary center between January 2010 and June 2015. All term singleton live births were eligible. Cases were divided into four groups: head circumference ≥90th percentile both with birth weight ≥90th percentile and <90th percentile and fetal head circumference <90th percentile with birth weight ≥90th and <90th percentile. Risk of failed vacuum extraction was compared among these groups. Other neonatal and maternal parameters were also evaluated as potential risk factors. Multinomial multivariable regression provided adjusted odds ratio for vacuum extraction failure while controlling for potential confounders. During the study period, 48,007 deliveries met inclusion criteria, of which 3835 had an attempt at vacuum extraction. We identified 215 (5.6%) cases of vacuum extraction failure. The adjusted odds ratios (aOR) for vacuum extraction failure in cases of large fetal head circumference was 2.31 (95%CI, 1.7-3.15, p < .001). Primiparity, prolonged second stage and occipito-posterior presentation were also found to be significant risk factors for failed vacuum extraction. In this study, we found that large head circumference was associated with vacuum extraction failure rather than high birth weight.

  11. Light scattering from laser induced pit ensembles on high power laser optics

    DOE PAGES

    Feigenbaum, Eyal; Elhadj, Selim; Matthews, Manyalibo J.

    2015-01-01

    Far-field light scattering characteristics from randomly arranged shallow Gaussian-like shaped laser induced pits, found on optics exposed to high energy laser pulses, is studied. Closed-form expressions for the far-field intensity distribution and scattered power are derived for individual pits and validated using numerical calculations of both Fourier optics and FDTD solutions to Maxwell’s equations. It is found that the scattered power is proportional to the square of the pit width and approximately also to the square of the pit depth, with the proportionality factor scaling with pit depth. As a result, the power scattered from shallow pitted optics is expectedmore » to be substantially lower than assuming complete scattering from the total visible footprint of the pits.« less

  12. Evolution of the scattering anisotropy of aged foams in the wet-to-dry transition

    NASA Astrophysics Data System (ADS)

    Zimnyakov, D. A.; Yuvchenko, S. A.; Isaeva, A. A.; Isaeva, E. A.; Samorodina, T. V.

    2018-04-01

    Empirical data on the diffuse and collimated transmittance of aged liquid foams are discussed in terms of influence of mutual correlations in the scatter positions. This influence can be described introducing the static structure factor of a scattering system and occurs remarkable in the case of wet foams with gas bubbles as the basic scattering units. On the contrary, mutual correlations of basic scattering units (Plateau-Gibbs channels and vertices) in dry foams are negligible due to low values of their volume fraction. This causes dramatic changes of the scattering anisotropy of foam layers in the vicinity of the wet-to-dry transition. Some analogies can be drawn between this effect and a previously reported "optical inversion" of densely packed random media.

  13. A safe, low-cost, and portable instrumentation for bedside time-resolved picosecond near infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Amouroux, Marine; Uhring, Wilfried; Pebayle, Thierry; Poulet, Patrick; Marlier, Luc

    2009-07-01

    Continuous wave Near InfraRed Spectroscopy (NIRS) has been used successfully in clinical environments for several years to detect cerebral activation thanks to oxymetry (i.e. absorption of photons by oxy- and deoxy- hemoglobin) measurement. The goal of our group is to build a clinically-adapted time-resolved NIRS setup i.e. a setup that is compact and robust enough to allow bedside measurements and that matches safety requirements with human patients applications. Indeed our group has already shown that time resolution allows spatial resolution and improves sensitivity of cerebral activation detection. The setup is built with four laser diodes (excitation wavelengths: 685, 780, 830 and 870 nm) whose emitted light is injected into four optical fibers; detection of reflected photons is made through an avalanche photodiode and a high resolution timing module used to record Temporal Point Spread Functions (TPSF). Validation of the device was made using cylindrically-chaped phantoms with absorbing and/or scattering inclusions. Results show that recorded TPSF are typical both of scattering and absorbing materials thus demonstrating that our apparatus would detect variation of optical properties (absorption and scattering) deep within a diffusive media just like a cerebral activation represents a rise of absorption in the cortex underneath head surface.

  14. Sonographic large fetal head circumference and risk of cesarean delivery.

    PubMed

    Lipschuetz, Michal; Cohen, Sarah M; Israel, Ariel; Baron, Joel; Porat, Shay; Valsky, Dan V; Yagel, Oren; Amsalem, Hagai; Kabiri, Doron; Gilboa, Yinon; Sivan, Eyal; Unger, Ron; Schiff, Eyal; Hershkovitz, Reli; Yagel, Simcha

    2018-03-01

    Persistently high rates of cesarean deliveries are cause for concern for physicians, patients, and health systems. Prelabor assessment might be refined by identifying factors that help predict an individual patient's risk of cesarean delivery. Such factors may contribute to patient safety and satisfaction as well as health system planning and resource allocation. In an earlier study, neonatal head circumference was shown to be more strongly associated with delivery mode and other outcome measures than neonatal birthweight. In the present study we aimed to evaluate the association of sonographically measured fetal head circumference measured within 1 week of delivery with delivery mode. This was a multicenter electronic medical record-based study of birth outcomes of primiparous women with term (37-42 weeks) singleton fetuses presenting for ultrasound with fetal biometry within 1 week of delivery. Fetal head circumference and estimated fetal weight were correlated with maternal background, obstetric, and neonatal outcome parameters. Elective cesarean deliveries were excluded. Multinomial regression analysis provided adjusted odds ratios for instrumental delivery and unplanned cesarean delivery when the fetal head circumference was ≥35 cm or estimated fetal weight ≥3900 g, while controlling for possible confounders. In all, 11,500 cases were collected; 906 elective cesarean deliveries were excluded. A fetal head circumference ≥35 cm increased the risk for unplanned cesarean delivery: 174 fetuses with fetal head circumference ≥35 cm (32%) were delivered by cesarean, vs 1712 (17%) when fetal head circumference <35 cm (odds ratio, 2.49; 95% confidence interval, 2.04-3.03). A fetal head circumference ≥35 cm increased the risk of instrumental delivery (odds ratio, 1.48; 95% confidence interval, 1.16-1.88), while estimated fetal weight ≥3900 g tended to reduce it (nonsignificant). Multinomial regression analysis showed that fetal head circumference ≥35 cm increased the risk of unplanned cesarean delivery by an adjusted odds ratio of 1.75 (95% confidence interval, 1.4-2.18) controlling for gestational age, fetal gender, and epidural anesthesia. The rate of prolonged second stage of labor was significantly increased when either the fetal head circumference was ≥35 cm or the estimated fetal weight ≥3900 g, from 22.7% in the total cohort to 31.0%. A fetal head circumference ≥35 cm was associated with a higher rate of 5-minute Apgar score ≤7: 9 (1.7%) vs 63 (0.6%) of infants with fetal head circumference <35 cm (P = .01). The rate among fetuses with an estimated fetal weight ≥3900 g was not significantly increased. The rate of admission to the neonatal intensive care unit did not differ among the groups. Sonographic fetal head circumference ≥35 cm, measured within 1 week of delivery, is an independent risk factor for unplanned cesarean delivery but not instrumental delivery. Both fetal head circumference ≥35 cm and estimated fetal weight ≥3900 g significantly increased the risk of a prolonged second stage of labor. Fetal head circumference measurement in the last days before delivery may be an important adjunct to estimated fetal weight in labor management. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. SU-E-I-77: X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4.

    PubMed

    Kapadia, A; Samei, E; Harrawood, B; Sahbaee, P; Chawla, A; Tan, Z; Brady, D

    2012-06-01

    To model X-ray coherent scatter diffraction patterns in GEANT4 for simulating experiments involving material detection through diffraction pattern measurement. Although coherent scatter cross-sections are modeled accurately in GEANT4, diffraction patterns for crystalline materials are not yet included. Here we describe our modeling of crystalline diffraction patterns in GEANT4 for specific materials and the validation of the results against experimentally measured data. Coherent scatter in GEANT4 is currently based on Hubbell's non-relativistic form factor tabulations from EPDL97. We modified the form-factors by introducing an interference function that accounts for the angular dependence between the Rayleigh-scattered photons and the photon wavelength. The modified form factors were used to replace the inherent form-factors in GEANT4. The simulation was tested using monochromatic and polychromatic x-ray beams (separately) incident on objects containing one or more elements with modified form-factors. The simulation results were compared against the experimentally measured diffraction images of corresponding objects using an in-house x-ray diffraction imager for validation. The comparison was made using the following metrics: number of diffraction rings, radial distance, absolute intensity, and relative intensity. Sharp diffraction pattern rings were observed in the monochromatic simulations at locations consistent with the angular dependence of the photon wavelength. In the polychromatic simulations, the diffraction patterns exhibited a radial blur consistent with the energy spread of the polychromatic spectrum. The simulated and experimentally measured patterns showed identical numbers of rings with close agreement in radial distance, absolute and relative intensities (barring statistical fluctuations). No significant change was observed in the execution time of the simulations. This work demonstrates the ability to model coherent scatter diffraction in GEANT4 in an accurate and efficient manner without compromising the accuracy or runtime of the simulation. This work was supported by the Department of Homeland Security under grant DHS (BAA 10-01 F075), and by the Department of Defense under award W81XWH-09-1-0066. © 2012 American Association of Physicists in Medicine.

  16. A new theory for X-ray diffraction

    PubMed Central

    Fewster, Paul F.

    2014-01-01

    This article proposes a new theory of X-ray scattering that has particular relevance to powder diffraction. The underlying concept of this theory is that the scattering from a crystal or crystallite is distributed throughout space: this leads to the effect that enhanced scatter can be observed at the ‘Bragg position’ even if the ‘Bragg condition’ is not satisfied. The scatter from a single crystal or crystallite, in any fixed orientation, has the fascinating property of contributing simultaneously to many ‘Bragg positions’. It also explains why diffraction peaks are obtained from samples with very few crystallites, which cannot be explained with the conventional theory. The intensity ratios for an Si powder sample are predicted with greater accuracy and the temperature factors are more realistic. Another consequence is that this new theory predicts a reliability in the intensity measurements which agrees much more closely with experimental observations compared to conventional theory that is based on ‘Bragg-type’ scatter. The role of dynamical effects (extinction etc.) is discussed and how they are suppressed with diffuse scattering. An alternative explanation for the Lorentz factor is presented that is more general and based on the capture volume in diffraction space. This theory, when applied to the scattering from powders, will evaluate the full scattering profile, including peak widths and the ‘background’. The theory should provide an increased understanding of the reliability of powder diffraction measurements, and may also have wider implications for the analysis of powder diffraction data, by increasing the accuracy of intensities predicted from structural models. PMID:24815975

  17. At-edge minima in elastic photon scattering amplitudes for dilute aqueous ions

    NASA Astrophysics Data System (ADS)

    Bradley, D. A.; Hugtenburg, R. P.; Yusoff, A. L.

    2006-11-01

    Elastic photon scattering and absorption in the vicinity of core atomic orbital energies give rise to resonances in the elastic photon scattering cross-section. Of interest is whether a dilute-ion aqueous system provides an environment suitable for testing independent particle approximation (IPA) predictions. Predictions of the energy of these resonances have been determined for a Dirac-Slater exchange potential with a Latter tail. At BM28 (ESRF), tuneable X-rays were obtained at eV resolution using a 1 1 1 Si monochromator. From target systems including Cu 2+ and Zn 2+, the X-rays were scattered through high angle from an aqueous medium contained in a thin Perspex cell provided with 8 μm kaplan windows. An energy resolution of ˜500 eV from the HPGe detector was adequate to separate the elastic scattering signal from K α radiation but not from Compton or K β contributions. The Compton contribution from the medium was removed assuming validity of the relativistic impulse approximation. The contribution due to K β fluorescence and the resonant X-ray Raman scattering process were handled by assuming the branching ratio for K α and K β contributions to be constant and to be accurately described by fluorescent yields measured above edge. At ionic concentrations ranging from 0.01 to 0.1 mol/l, resonance structures accord with predictions of elastic scattering cross-sections calculated within IPA. Amplitudes calculated using modified form-factors and anomalous scatter factors computed from a Dirac-Slater exchange potential were convolved with a Lorentzian of several eV (FWHM).

  18. Numerical Studies of Scattering Properties of Leaves and Leaf Moisture Influences on the Scattering at Microwave Wavelengths

    NASA Technical Reports Server (NTRS)

    Lin, Bing; Hu, Yongxiang; Sun, Wenbo; Min, Qilong

    2008-01-01

    This study uses 3-dimensional finite difference time domain method to accurately calculate single-scattering properties of randomly orientated leaves and evaluate the influences of vegetation water content (VWC) on these properties at 19 and 37 GHz frequencies. The studied leaves are assumed to be thin elliptic disks with two different sizes and have various VWC values. Although the leaf moisture produces considerable absorption during scattering processes, the effective efficiencies of extinction and scattering of leaves still near-linearly increase with VWC. Calculated asymmetry factors and phase functions indicate that there are significant amounts of scattering at large scattering angles in microwave wavelengths, which provides good opportunities for off-nadir microwave remote sensing of forests. This study lays a basic foundation in future quantifications of the relations between satellite measurements and physical properties of vegetation canopies.

  19. Head circumference, leg length and its association with dementia among older adult population in Singapore.

    PubMed

    Chang, Sherilyn; Ong, Hui Lin; Abdin, Edimansyah; Vaingankar, Janhavi Ajit; Jeyagurunathan, Anitha; Shafie, Saleha; Mahendran, Rathi; Subramaniam, Mythily; Chong, Siow Ann

    2017-12-01

    Head circumference and leg length serve as reliable proxy indicators of early-life environment. Research studies have shown that these anthropometric measurements are associated with cognitive impairment and dementia among older adults. The aim of the present study was to assess the associations between dementia with head circumference and leg length among the older adult population in Singapore. This study also aimed to examine the sociodemographic correlates of these anthropometric measurements. Data were collected from 2565 older adults aged 60 years and above, in a population study on the Well-being of the Singapore Elderly. Head circumference and leg length measurements were obtained, and sociodemographic information was recorded. Dementia diagnosis was made using the 10/66 dementia algorithm. Anthropometric measurements were first stratified into quarters, and then logistic regression analysis was used to examine factors associated with head circumference and leg length, as well as to examine the association between dementia with these measurements. Sociodemographic correlates of head circumference and leg length include age, gender, ethnicity and education level. Smaller head circumference was independently associated with higher odds of 10/66 dementia (OR = 2.173-2.709). When the regression analysis was stratified by gender, the association was found only in the male sample. Leg length was not significantly associated with dementia after controlling for sociodemographic variables. Smaller head circumference is independently associated with dementia among older adults in Singapore. Findings from this study suggest that risk factors for dementia begin their influence in early life. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Chordin and dickkopf-1b are essential for the formation of head structures through activation of the FGF signaling pathway in zebrafish.

    PubMed

    Tanaka, Shingo; Hosokawa, Hiroshi; Weinberg, Eric S; Maegawa, Shingo

    2017-04-15

    The ability of the Spemann organizer to induce dorsal axis formation is dependent on downstream factors of the maternal Wnt/β-catenin signaling pathway. The fibroblast growth factor (FGF) signaling pathway has been identified as one of the downstream components of the maternal Wnt/β-catenin signaling pathway. The ability of the FGF signaling pathway to induce the formation of a dorsal axis with a complete head structure requires chordin (chd) expression; however, the molecular mechanisms involved in this developmental process, due to activation of FGF signaling, remain unclear. In this study, we showed that activation of the FGF signaling pathway induced the formation of complete head structures through the expression of chd and dickkopf-1b (dkk1b). Using the organizer-deficient maternal mutant, ichabod, we identified dkk1b as a novel downstream factor in the FGF signaling pathway. We also demonstrate that dkk1b expression is necessary, after activation of the FGF signaling pathway, to induce neuroectoderm patterning along the anteroposterior (AP) axis and for formation of complete head structures. Co-injection of chd and dkk1b mRNA resulted in the formation of a dorsal axis with a complete head structure in ichabod embryos, confirming the role of these factors in this developmental process. Unexpectedly, we found that chd induced dkk1b expression in ichabod embryos at the shield stage. However, chd failed to maintain dkk1b expression levels in cells of the shield and, subsequently, in the cells of the prechordal plate after mid-gastrula stage. In contrast, activation of the FGF signaling pathway maintained the dkk1b expression from the beginning of gastrulation to early somitogenesis. In conclusion, activation of the FGF signaling pathway induces the formation of a dorsal axis with a complete head structure through the expression of chd and subsequent maintenance of dkk1b expression levels. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. LASER BIOLOGY AND MEDICINE: Light scattering study of rheumatoid arthritis

    NASA Astrophysics Data System (ADS)

    Beuthan, J.; Netz, U.; Minet, O.; Klose, Annerose D.; Hielscher, A. H.; Scheel, A.; Henniger, J.; Müller, G.

    2002-11-01

    The distribution of light scattered by finger joints is studied in the near-IR region. It is shown that variations in the optical parameters of the tissue (scattering coefficient μs, absorption coefficient μa, and anisotropy factor g) depend on the presence of the rheumatoid arthritis (RA). At the first stage, the distribution of scattered light was measured in diaphanoscopic experiments. The convolution of a Gaussian error function with the scattering phase function proved to be a good approximation of the data obtained. Then, a new method was developed for the reconstruction of distribution of optical parameters in the finger cross section. Model tests of the quality of this reconstruction method show good results.

  2. Impact of optical phonon scattering on inversion channel mobility in 4H-SiC trenched MOSFETs

    NASA Astrophysics Data System (ADS)

    Kutsuki, Katsuhiro; Kawaji, Sachiko; Watanabe, Yukihiko; Onishi, Toru; Fujiwara, Hirokazu; Yamamoto, Kensaku; Yamamoto, Toshimasa

    2017-04-01

    Temperature characteristics of the channel mobility were investigated for 4H-SiC trenched MOSFETs in the range from 30 to 200 °C. The conventional model of channel mobility limited by carrier scattering is based on Si-MOSFETs and shows a greatly different channel mobility from the experimental value, especially at high temperatures. On the other hand, our improved mobility model taking into account optical phonon scattering yielded results in excellent agreement with experimental results. Moreover, the major factors limiting the channel mobility were found to be Coulomb scattering in a low effective field (<0.7 MV/cm) and optical phonon scattering in a high effective field.

  3. Interaction Between Syntactic Structure and Information Structure in the Processing of a Head-Final Language.

    PubMed

    Koizumi, Masatoshi; Imamura, Satoshi

    2017-02-01

    The effects of syntactic and information structures on sentence processing load were investigated using two reading comprehension experiments in Japanese, a head-final SOV language. In the first experiment, we discovered the main effects of syntactic and information structures, as well as their interaction, showing that interaction of these two factors is not restricted to head-initial languages. The second experiment revealed that the interaction between syntactic structure and information structure occurs at the second NP (O of SOV and S of OSV), which, crucially, is a pre-head position, suggesting the incremental nature of the processing of both syntactic structure and information structure in head-final languages.

  4. Effects of Pediatric Head Trauma for Children, Parents, and Families

    PubMed Central

    Youngblut, JoAnne M.; Singer, Lynn T.; Boyer, Cindy; Wheatley, Margaret A.; Cohen, Alan R.; Grisoni, Enrique R.

    2013-01-01

    SUMMARY Severe pediatric head injury has negative consequences for children of all ages. Even mild and moderate head injury results in residual impairment for school-age children and adolescents. Data are needed on the effects of these less severe insults, especially for preschoolers. Although research on the impact of the child’s head injury on the parent–child relationship and family functioning is limited, the experience is likely to be very stressful for the parent and the family. Indeed, family integrity may be at risk. Research is needed that examines the effects of a child’s head injury for the parent and the family over time and identifies factors related to these outcomes. PMID:11249368

  5. A new species of the genus Leptobrachium (Anura: Megophryidae) from the Gaoligongshan Mountain Range, China.

    PubMed

    Yang, Jian-Huan; Wang, Ying-Yong; Chan, Bosco Pui-Lok

    2016-08-11

    We describe a new species of the genus Leptobrachium from the Gaoligongshan Mountain Range, Yunnan Province of China based on molecular and morphological evidences. The new species, Leptobrachium tengchongense sp. nov., can be distinguished from its congeners by a combination of the following characters: (1) relatively small size (adult males SVL 41.7-51.5 mm); (2) head width slightly larger than head length; (3) tympanum indistinct; (4) two palmar tubercles oval and distinct, inner one larger than outer one; (5) sexually active males without spines on the upper lip; (6) dorsal skin smooth with distinct network of ridges; (7) dorsum pinkish grey and scattered with irregular black markings; (8) venter dark purplish-gray with numerous small white spots on tubercles, solid white chest; (9) iris bicolored, upper one-third light blue, lower two-third dark brown. With the description of the new species, the number of Leptobrachium species currently known from China adds up to ten.

  6. Estimation of the absorption coefficients of two-layered media by a simple method using spatially and time-resolved reflectances

    NASA Astrophysics Data System (ADS)

    Shimada, M.; Sato, C.; Hoshi, Y.; Yamada, Y.

    2009-08-01

    Our newly developed method using spatially and time-resolved reflectances can easily estimate the absorption coefficients of each layer in a two-layered medium if the thickness of the upper layer and the reduced scattering coefficients of the two layers are known a priori. We experimentally validated this method using phantoms and examined its possibility of estimating the absorption coefficients of the tissues in human heads. In the case of a homogeneous plastic phantom (polyacetal block), the absorption coefficient estimated by our method agreed well with that obtained by a conventional method. Also, in the case of two-layered phantoms, our method successfully estimated the absorption coefficients of the two layers. Furthermore, the absorption coefficients of the extracerebral and cerebral tissue inside human foreheads were estimated under the assumption that the human heads were two-layered media. It was found that the absorption coefficients of the cerebral tissues were larger than those of the extracerebral tissues.

  7. NIR time domain diffuse optical tomography experiments on human forearm

    NASA Astrophysics Data System (ADS)

    Zhao, Huijuan; Gao, Feng; Tanikawa, Yukari; Homma, Kazuhiro; Yamada, Yukio

    2003-07-01

    To date, the applications of near infrared (NIR) diffusion optical tomography (DOT) are mostly focused on the potential of imaging woman breast, human head hemodynamics and neonatal head. For the neonates, who are suffered from ischaemia or hemorrhages in brain, bedside monitoring of the cerebral perfusion situation, e.g., the blood oxygen saturation and blood volume, is necessary for avoiding permanent injure. NIR DOT is on the promising tools because it is noninvasive, smaller in size, and moveable. Prior to achieving the ultimate goal of imaging infant brain and woman breast using DOT, in this paper, the developed methodologies are justified by imaging in vivo human forearms. The absolute absorption- and scattering-coefficient images revealed the inner structure of the forearm and the bones were clearly distinguished from the muscle. The differential images showed the changes in oxy-hemoglobin, deoxy-hemoglobin and blood volume during the hand-gripping exercises, which are consistent with the physiological process reported on literatures.

  8. Lipid14: The Amber Lipid Force Field

    PubMed Central

    2015-01-01

    The AMBER lipid force field has been updated to create Lipid14, allowing tensionless simulation of a number of lipid types with the AMBER MD package. The modular nature of this force field allows numerous combinations of head and tail groups to create different lipid types, enabling the easy insertion of new lipid species. The Lennard-Jones and torsion parameters of both the head and tail groups have been revised and updated partial charges calculated. The force field has been validated by simulating bilayers of six different lipid types for a total of 0.5 μs each without applying a surface tension; with favorable comparison to experiment for properties such as area per lipid, volume per lipid, bilayer thickness, NMR order parameters, scattering data, and lipid lateral diffusion. As the derivation of this force field is consistent with the AMBER development philosophy, Lipid14 is compatible with the AMBER protein, nucleic acid, carbohydrate, and small molecule force fields. PMID:24803855

  9. Contrast variation by dynamic nuclear polarization and time-of-flight small-angle neutron scattering. I. Application to industrial multi-component nanocomposites.

    PubMed

    Noda, Yohei; Koizumi, Satoshi; Masui, Tomomi; Mashita, Ryo; Kishimoto, Hiroyuki; Yamaguchi, Daisuke; Kumada, Takayuki; Takata, Shin-Ichi; Ohishi, Kazuki; Suzuki, Jun-Ichi

    2016-12-01

    Dynamic nuclear polarization (DNP) at low temperature (1.2 K) and high magnetic field (3.3 T) was applied to a contrast variation study in small-angle neutron scattering (SANS) focusing on industrial rubber materials. By varying the scattering contrast by DNP, time-of-flight SANS profiles were obtained at the pulsed neutron source of the Japan Proton Accelerator Research Complex (J-PARC). The concentration of a small organic molecule, (2,2,6,6-tetramethylpiperidine-1-yl)oxy (TEMPO), was carefully controlled by a doping method using vapour sorption into the rubber specimens. With the assistance of microwave irradiation (94 GHz), almost full polarization of the paramagnetic electronic spin of TEMPO was transferred to the spin state of hydrogen (protons) in the rubber materials to obtain a high proton spin polarization ( P H ). The following samples were prepared: (i) a binary mixture of styrene-butadiene random copolymer (SBR) with silica particles (SBR/SP); and (ii) a ternary mixture of SBR with silica and carbon black particles (SBR/SP/CP). For the binary mixture (SBR/SP), the intensity of SANS significantly increased or decreased while keeping its q dependence for P H = -35% or P H = 40%, respectively. The q behaviour of SANS for the SBR/SP mixture can be reproduced using the form factor of a spherical particle. The intensity at low q (∼0.01 Å -1 ) varied as a quadratic function of P H and indicated a minimum value at P H = 30%, which can be explained by the scattering contrast between SP and SBR. The scattering intensity at high q (∼0.3 Å -1 ) decreased with increasing P H , which is attributed to the incoherent scattering from hydrogen. For the ternary mixture (SBR/SP/CP), the q behaviour of SANS was varied by changing P H . At P H = -35%, the scattering maxima originating from the form factor of SP prevailed, whereas at P H = 29% and P H = 38%, the scattering maxima disappeared. After decomposition of the total SANS according to inverse matrix calculations, the partial scattering functions were obtained. The partial scattering function obtained for SP was well reproduced by a spherical form factor and matched the SANS profile for the SBR/SP mixture. The partial scattering function for CP exhibited surface fractal behaviour according to q -3.6 , which is consistent with the results for the SBR/CP mixture.

  10. Contrast variation by dynamic nuclear polarization and time-of-flight small-angle neutron scattering. I. Application to industrial multi-component nanocomposites1

    PubMed Central

    Noda, Yohei; Koizumi, Satoshi; Masui, Tomomi; Mashita, Ryo; Kishimoto, Hiroyuki; Yamaguchi, Daisuke; Kumada, Takayuki; Takata, Shin-ichi; Ohishi, Kazuki; Suzuki, Jun-ichi

    2016-01-01

    Dynamic nuclear polarization (DNP) at low temperature (1.2 K) and high magnetic field (3.3 T) was applied to a contrast variation study in small-angle neutron scattering (SANS) focusing on industrial rubber materials. By varying the scattering contrast by DNP, time-of-flight SANS profiles were obtained at the pulsed neutron source of the Japan Proton Accelerator Research Complex (J-PARC). The concentration of a small organic molecule, (2,2,6,6-tetramethylpiperidine-1-yl)oxy (TEMPO), was carefully controlled by a doping method using vapour sorption into the rubber specimens. With the assistance of microwave irradiation (94 GHz), almost full polarization of the paramagnetic electronic spin of TEMPO was transferred to the spin state of hydrogen (protons) in the rubber materials to obtain a high proton spin polarization (P H). The following samples were prepared: (i) a binary mixture of styrene–butadiene random copolymer (SBR) with silica particles (SBR/SP); and (ii) a ternary mixture of SBR with silica and carbon black particles (SBR/SP/CP). For the binary mixture (SBR/SP), the intensity of SANS significantly increased or decreased while keeping its q dependence for P H = −35% or P H = 40%, respectively. The q behaviour of SANS for the SBR/SP mixture can be reproduced using the form factor of a spherical particle. The intensity at low q (∼0.01 Å−1) varied as a quadratic function of P H and indicated a minimum value at P H = 30%, which can be explained by the scattering contrast between SP and SBR. The scattering intensity at high q (∼0.3 Å−1) decreased with increasing P H, which is attributed to the incoherent scattering from hydrogen. For the ternary mixture (SBR/SP/CP), the q behaviour of SANS was varied by changing P H. At P H = −35%, the scattering maxima originating from the form factor of SP prevailed, whereas at P H = 29% and P H = 38%, the scattering maxima disappeared. After decomposition of the total SANS according to inverse matrix calculations, the partial scattering functions were obtained. The partial scattering function obtained for SP was well reproduced by a spherical form factor and matched the SANS profile for the SBR/SP mixture. The partial scattering function for CP exhibited surface fractal behaviour according to q −3.6, which is consistent with the results for the SBR/CP mixture. PMID:27980510

  11. Towards a Resolution of the Proton Form Factor Problem: New Electron and Positron Scattering Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adikaram, D.; Rimal, D.; Weinstein, L. B.

    There is a significant discrepancy between the values of the proton electric form factor, GpE, extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of GpE from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (epsilon) and momentummore » transfer (Q2) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ε at Q2=1.45 GeV2. This measurement is consistent with the size of the form factor discrepancy at Q2≈1.75 GeV2 and with hadronic calculations including nucleon and Delta intermediate states, which have been shown to resolve the discrepancy up to 2-3 GeV2.« less

  12. On the Validity of Certain Approximations Used in the Modeling of Nuclear EMP

    DOE PAGES

    Farmer, William A.; Cohen, Bruce I.; Eng, Chester D.

    2016-04-01

    The legacy codes developed for the modeling of EMP, multiple scattering of Compton electrons has typically been modeled by the obliquity factor. A recent publication has examined this approximation in the context of the generated Compton current [W. A. Farmer and A. Friedman, IEEE Trans. Nucl. Sc. 62, 1695 (2015)]. Here, this previous analysis is extended to include the generation of the electromagnetic fields. Obliquity factor predictions are compared with Monte-Carlo models. In using a Monte-Carlo description of scattering, two distributions of scattering angles are considered: Gaussian and a Gaussian with a single-scattering tail. Additionally, legacy codes also neglect themore » radial derivative of the backward-traveling wave for computational efficiency. The neglect of this derivative improperly treats the backward-traveling wave. Moreover, these approximations are examined in the context of a high-altitude burst, and it is shown that in comparison to more complete models, the discrepancy between field amplitudes is roughly two to three percent and between rise-times, 10%. Finally, it is concluded that the biggest factor in determining the rise time of the signal is not the dynamics of the Compton current, but is instead the conductivity.« less

  13. A re-evaluation of thermal expansion measurements of metallic liquids and glasses from x-ray scattering experiments

    NASA Astrophysics Data System (ADS)

    Gangopadhyay, A. K.; Kelton, K. F.

    2018-05-01

    Previous studies reported a number of anomalies when estimates of linear thermal expansion coefficients of metallic liquids and glasses from x-ray scattering experiments were compared with direct measurements of volume/length changes with temperature. In most cases, the first peak of the pair correlation function showed a contraction, while the structure factor showed an expansion, but both at rates much different from those expected from the direct volume measurements. In addition, the relationship between atomic volume and the characteristic lengths obtained from the structure factor from scattering experiments was found to have a fractional exponent instead of one equal to three, as expected from the Ehrenfest relation. This has led to the speculation that the atomic packing in liquids and glasses follow a fractal behavior. These issues are revisited in this study using more in-depth analysis of recent higher resolution data and some new ideas suggested in the literature. The main conclusion is that for metallic alloys, at least to a large extent, most of these anomalies arise from complicated interplays of the temperature dependences of the various partial structure factors, which contribute to the total intensities of the scattering peaks.

  14. Towards a Resolution of the Proton Form Factor Problem: New Electron and Positron Scattering Data

    DOE PAGES

    Adikaram, D.; Rimal, D.; Weinstein, L. B.; ...

    2015-02-10

    There is a significant discrepancy between the values of the proton electric form factor, GpE, extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of GpE from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (epsilon) and momentummore » transfer (Q2) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ε at Q2=1.45 GeV2. This measurement is consistent with the size of the form factor discrepancy at Q2≈1.75 GeV2 and with hadronic calculations including nucleon and Delta intermediate states, which have been shown to resolve the discrepancy up to 2-3 GeV2.« less

  15. Towards a resolution of the proton form factor problem: new electron and positron scattering data.

    PubMed

    Adikaram, D; Rimal, D; Weinstein, L B; Raue, B; Khetarpal, P; Bennett, R P; Arrington, J; Brooks, W K; Adhikari, K P; Afanasev, A V; Amaryan, M J; Anderson, M D; Anefalos Pereira, S; Avakian, H; Ball, J; Battaglieri, M; Bedlinskiy, I; Biselli, A S; Bono, J; Boiarinov, S; Briscoe, W J; Burkert, V D; Carman, D S; Careccia, S; Celentano, A; Chandavar, S; Charles, G; Colaneri, L; Cole, P L; Contalbrigo, M; Crede, V; D'Angelo, A; Dashyan, N; De Vita, R; De Sanctis, E; Deur, A; Djalali, C; Dodge, G E; Dupre, R; Egiyan, H; El Alaoui, A; El Fassi, L; Elouadrhiri, L; Eugenio, P; Fedotov, G; Fegan, S; Filippi, A; Fleming, J A; Fradi, A; Garillon, B; Gilfoyle, G P; Giovanetti, K L; Girod, F X; Goetz, J T; Gohn, W; Golovatch, E; Gothe, R W; Griffioen, K A; Guegan, B; Guidal, M; Guo, L; Hafidi, K; Hakobyan, H; Hanretty, C; Harrison, N; Hattawy, M; Hicks, K; Holtrop, M; Hughes, S M; Hyde, C E; Ilieva, Y; Ireland, D G; Ishkhanov, B S; Jenkins, D; Jiang, H; Jo, H S; Joo, K; Joosten, S; Kalantarians, N; Keller, D; Khandaker, M; Kim, A; Kim, W; Klein, A; Klein, F J; Koirala, S; Kubarovsky, V; Kuhn, S E; Livingston, K; Lu, H Y; MacGregor, I J D; Markov, N; Mattione, P; Mayer, M; McKinnon, B; Mestayer, M D; Meyer, C A; Mirazita, M; Mokeev, V; Montgomery, R A; Moody, C I; Moutarde, H; Movsisyan, A; Camacho, C Munoz; Nadel-Turonski, P; Niccolai, S; Niculescu, G; Osipenko, M; Ostrovidov, A I; Park, K; Pasyuk, E; Peña, C; Pisano, S; Pogorelko, O; Price, J W; Procureur, S; Prok, Y; Protopopescu, D; Puckett, A J R; Ripani, M; Rizzo, A; Rosner, G; Rossi, P; Roy, P; Sabatié, F; Salgado, C; Schott, D; Schumacher, R A; Seder, E; Sharabian, Y G; Simonyan, A; Skorodumina, I; Smith, E S; Smith, G D; Sober, D I; Sokhan, D; Sparveris, N; Stepanyan, S; Stoler, P; Strauch, S; Sytnik, V; Taiuti, M; Tian, Ye; Trivedi, A; Ungaro, M; Voskanyan, H; Voutier, E; Walford, N K; Watts, D P; Wei, X; Wood, M H; Zachariou, N; Zana, L; Zhang, J; Zhao, Z W; Zonta, I

    2015-02-13

    There is a significant discrepancy between the values of the proton electric form factor, G(E)(p), extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of G(E)(p) from the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual photon polarization (ϵ) and momentum transfer (Q(2)) simultaneously, as well as to cancel luminosity-related systematic errors. The cross section ratio increases with decreasing ϵ at Q(2)=1.45  GeV(2). This measurement is consistent with the size of the form factor discrepancy at Q(2)≈1.75  GeV(2) and with hadronic calculations including nucleon and Δ intermediate states, which have been shown to resolve the discrepancy up to 2-3  GeV(2).

  16. Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children.

    PubMed

    Aw-Zoretic, J; Seth, D; Katzman, G; Sammet, S

    2014-10-01

    The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS). A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report. Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10-18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk. Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Scatter Measurements Made With Ultraviolet Light

    NASA Astrophysics Data System (ADS)

    Anthon, Erik W.

    1985-09-01

    The quality of optical surfaces is generally evaluated by how much light (normally visible light) is scattered by the surface. Most optical glasses and many coating materials are completely opaque to ultraviolet light (253.7 nm). Ultraviolet light tends to scatter much more than visible light. Scatter measurements made with ultraviolet light are therefore very sensitive and the scatter from second surfaces and from the interior (bulk) of the optical material is eliminated by the opacity. A novel scattermeter that operates with ultraviolet light has been developed. The construction and operation of this scattermeter will be described. Cleaning soon becomes the limiting factor when measuring the surfaces with very low level of scatter. Sensitivity to repeated cleaning has been investigated. Different surfaces are compared and uniformity of surfaces is measured by mapping a surface area with an x-y stage. Polished glass surfaces generally have much higher scatter than natural glass surfaces (fire polished, drawn or floated surfaces). Very low scatter levels have been found on thin drawn glass.

  18. A study of the polarization of light scattered by vegetation. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Woessner, P. N.

    1985-01-01

    This study was undertaken in order to better understand the factors that govern the polarization of light scattered from vegetation and soils. The intensity and polarization of light scattered by clover and grass in vivo and soil were measured at a number of different angles of incidence and reflectance. Both individual leaves and natural patches of leaves were measured. The light transmitted through the leaves was found to be negatively polarized. The light scattered from the upper leaf surface was found to be positively polarized in a manner which could be accounted for qualitatively but not quantitatively by the Fresnel reflection coefficients modified by a shadowing function of the form cos sup2 (g/2), where g is the phase angle. Findings indicate that the polarization of light scattered by vegetation is a more complex process than previously thought, and that besides the surface-scattered component of light, the volume-scattered and multiply-scattered components also contribute significantly to the polarization.

  19. [Measurement and analysis of human head-face dimensions].

    PubMed

    DU, Li-Li; Wang, Li-Min; Zhuang, Ziqing

    2008-05-01

    To probe into the physical changes on the head and face of Chinese adults, find the representative indexes and provide references for head-face products design especially in the field of labor protection. The ISO7250-1996 and GB/T5703-99 Basic Human Body Measurements for Technological Design was used. Twenty items of head-face referential parameters and 4 items of body indexes (height, weight, waist circumference and buttock circumference) were measured by using sliding caliper, spreading caliper and pupillometer. The populations were sampled by age, gender and region and their influences on the head and face dimensions were statistically analyzed. By studying the relationship between these parameters with correlation and cluster analysis, the representative indexes of head and face dimensions were concluded. 3000 objectives (2026 men and 974 women) were involved in this survey. The results enunciated that the values of the items in male were larger than those in female. For example, the mean values of face length, face width, jaw width, lip length and nose protrusion were 117.0, 147.6, 118.5, 51.7, 18.7 mm for male and 109.7, 140.1, 114.5, 49.3, 17.7 mm for female. The regional disparity and obesity were significant factors. The sizes of head and face of north-eastern population were significantly bigger than those of south-western population except of maximum length of head, the length of lip and face configuration length. The sizes of head and face of obesity population were significantly bigger than those of non-obesity population (P < 0.01). By the cluster analysis, five representative indexes (face length, face width, jaw width, lip length and nose protrusion) were obtained. Further correction analysis suggested that these indexes could well represent the head-face dimensions. The influence of gender, region and obesity on the head-face dimensions is significant. The age is not a significant influential factor. Five representative indexes (face length, face width, jaw width, lip length and nose protrusion) are obtained to provide foundation in the standard design of head-face products.

  20. Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.

    PubMed

    Kocagoz, Sevi B; Underwood, Richard J; MacDonald, Daniel W; Gilbert, Jeremy L; Kurtz, Steven M

    2016-04-01

    Metal release resulting from taper fretting and corrosion is a clinical concern, because wear and corrosion products may stimulate adverse local tissue reactions. Unimodular hip arthroplasties have a conical taper between the femoral head (head bore taper) and the femoral stem (stem cone taper). The use of ceramic heads has been suggested as a way of reducing the generation of wear and corrosion products from the head bore/stem cone taper junction. A previous semiquantitative study found that ceramic heads had less visual evidence of fretting-corrosion damage compared with CoCr heads; but, to our knowledge, no studies have quantified the volumetric material loss from the head bore and stem cone tapers of a matched cohort of ceramic and metal heads. We asked: (1) Do ceramic heads result in less volume of material loss at the head-stem junction compared with CoCr heads; (2) do stem cone tapers have less volumetric material loss compared with CoCr head bore tapers; (3) do visual fretting-corrosion scores correlate with volumetric material loss; and (4) are device, patient, or intraoperative factors associated with volumetric material loss? A quantitative method was developed to estimate volumetric material loss from the head and stem taper in previously matched cohorts of 50 ceramic and 50 CoCr head-stem pairs retrieved during revision surgery for causes not related to adverse reactions to metal particles. The cohorts were matched according to (1) implantation time, (2) stem flexural rigidity, and (3) lateral offset. Fretting corrosion was assessed visually using a previously published four-point, semiquantitative scoring system. The volumetric loss was measured using a precision roundness machine. Using 24 equally spaced axial traces, the volumetric loss was estimated using a linear least squares fit to interpolate the as-manufactured surfaces. The results of this analysis were considered in the context of device (taper angle clearance, head size, head offset, lateral offset, stem material, and stem surface finish) and patient factors that were obtained from the patients' operative records (implantation time, age at insertion, activity level, and BMI). The cumulative volumetric material losses estimated for the ceramic cohort had a median of 0.0 mm(3) per year (range, 0.0-0.4 mm(3)). The cumulative volumetric material losses estimated for the CoCr cohort had a median of 0.1 mm(3) per year (range, 0.0-8.8 mm(3)). An order of magnitude reduction in volumetric material loss was found when a ceramic head was used instead of a CoCr head (p < 0.0001). In the CoCr cohort, the femoral head bore tapers had a median material loss of 0.02 mm(3) (range, 0.0-8.7 mm(3)) and the stem cone tapers had a median material loss of 0.0 mm(3) (range, 0.0-0.32 mm(3)/year). There was greater material loss from femoral head bore tapers compared with stem cone tapers in the CoCr cohort (p < 0.001). There was a positive correlation between visual scoring and volumetric material loss (Spearman's ρ = 0.67, p < 0.01). Although visual scoring was effective for preliminary screening to separate tapers with no or mild damage from tapers with moderate to severe damage, it was not capable of discriminating in the large range of material loss observed at the taper surfaces with moderate to severe fretting-corrosion damage, indicated with a score of 3 or 4. We observed no correlations between volumetric material loss and device and patient factors. The majority of estimated material loss from the head bore-stem cone junctions resulting from taper fretting and corrosion was from the CoCr head bore tapers as opposed to the stem cone tapers. Additionally, the total material loss from the ceramic cohort showed a reduction in the amount of metal released by an order of magnitude compared with the CoCr cohort. We found that ceramic femoral heads may be an effective means by which to reduce metal release caused by taper fretting and corrosion at the head bore-stem cone modular interface in THAs.

  1. Application of small-angle neutron scattering to the study of forces between magnetically chained monodisperse ferrofluid emulsion droplets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jain, Dr Nirmesh; Liu, Dr C K; Hawkett, Dr B. S.

    2014-01-01

    The optical magnetic chaining technique (MCT) developed by Leal-Calderon, Bibette and co-workers in the 1990 s allows precise measurements of force profiles between droplets in monodisperse ferrofluid emulsions. However, the method lacks an in-situ determination of droplet size and therefore requires the combination of separately acquired measurements of droplet chain periodicity versus an applied magnetic field from optical Bragg scattering and droplet diameter inferred from dynamic light scattering (DLS) to recover surface force-distance profiles between the colloidal particles. Compound refractive lens (CRL) focussed small-angle scattering (SANS) MCT should result in more consistent measurements of droplet size (form factor measurements inmore » the absence of field) and droplet chaining period (from structure factor peaks when the magnetic field is applied); and, with access to shorter length scales, extend force measurements to closer approaches than possible by optical measurements. We report on CRL-SANS measurements of monodisperse ferrofluid emulsion droplets aligned in straight chains by an applied field perpendicular to the incident beam direction. Analysis of the scattering from the closely spaced droplets required algorithms that carefully treated resolution and its effect on mean scattering vector magnitudes in order to determine droplet size and chain periods to sufficient accuracy. At lower applied fields scattering patterns indicate structural correlations transverse to the magnetic field direction due to the formation of intermediate structures in early chain growth.« less

  2. STUDY OF THE INELASTIC SCATTERING OF ELECTRONS BY THE NUCLEI $sup 6$Li AND $sup 7$Li (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernheim, M.; Bishop, G.R.

    1963-11-01

    We have measured the form factors for transitions to the following excited states by the inelastic scattering of electrons: 2.189, 3.57, and 4.52 Mev of /sup 6/Li; and 0.478, 4.61, 5.76, and 6.8 Mev of /sup 7/Li. The dependence of the form factors on the momentum transfer indicates the principal components of the wave functions describing these states. (auth)

  3. Reading compounds in neglect dyslexia: the headedness effect.

    PubMed

    Semenza, Carlo; Arcara, Giorgio; Facchini, Silvia; Meneghello, Francesca; Ferraro, Marco; Passarini, Laura; Pilosio, Cristina; Vigato, Giovanna; Mondini, Sara

    2011-09-01

    Reading compound words was studied in neglect dyslexia in order to assess the influence of 'headedness'. The 'head' of a compound is the component that determines the grammatical category, the syntactic (e.g., the gender) and the semantic properties of the compound as a whole. For example, in the word 'blackberry'berry is the compound's head. The question was addressed of whether or not the privileged status of the head constituent influences processing and determines behavioural patterns in the breakdown of spatial attention in neglect. Italian right-headed (e.g. capobanda, band leader) and left-headed compounds (e.g. astronave, spaceship) were administered to 18 participants affected by neglect dyslexia. Left-headed compounds were read better than right-headed compounds. This result was not due to factors such as frequency, familiarity, age of acquisition or imageability, since these effects were controlled. It is suggested that attention is captured by the head component after implicit reading of the whole word. The head would require a relatively lighter processing load than the modifier and benefit from top-down facilitation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Dose distribution for dental cone beam CT and its implication for defining a dose index

    PubMed Central

    Pauwels, R; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Horner, K; Bogaerts, R

    2012-01-01

    Objectives To characterize the dose distribution for a range of cone beam CT (CBCT) units, investigating different field of view sizes, central and off-axis geometries, full or partial rotations of the X-ray tube and different clinically applied beam qualities. The implications of the dose distributions on the definition and practicality of a CBCT dose index were assessed. Methods Dose measurements on CBCT devices were performed by scanning cylindrical head-size water and polymethyl methacrylate phantoms, using thermoluminescent dosemeters, a small-volume ion chamber and radiochromic films. Results It was found that the dose distribution can be asymmetrical for dental CBCT exposures throughout a homogeneous phantom, owing to an asymmetrical positioning of the isocentre and/or partial rotation of the X-ray source. Furthermore, the scatter tail along the z-axis was found to have a distinct shape, generally resulting in a strong drop (90%) in absorbed dose outside the primary beam. Conclusions There is no optimal dose index available owing to the complicated exposure geometry of CBCT and the practical aspects of quality control measurements. Practical validation of different possible dose indices is needed, as well as the definition of conversion factors to patient dose. PMID:22752320

  5. Elastic Electron Scattering from Tritium and Helium-3

    DOE R&D Accomplishments Database

    Collard, H.; Hofstadter, R.; Hughes, E. B.; Johansson, A.; Yearian, M. R.; Day, R. B.; Wagner, R. T.

    1964-10-01

    The mirror nuclei of tritium and helium-3 have been studied by the method of elastic electron scattering. Absolute cross sections have been measured for incident electron energies in the range 110 - 690 MeV at scattering angles lying between 40 degrees and 135 degrees in this energy range. The data have been interpreted in a straightforward manner and form factors are given for the distributions of charge and magnetic moment in the two nuclei over a range of four-momentum transfer squared 1.0 - 8.0 F{sup -2}. Model-independent radii of the charge and magnetic moment distributions are given and an attempt is made to deduce form factors describing the spatial distribution of the protons in tritium and helium-3.

  6. Enhanced Raman scattering of single nanoparticles in a high-Q whispering-gallery microresonator

    NASA Astrophysics Data System (ADS)

    Liu, Rui-Shan; Jin, Wei-Liang; Yu, Xiao-Chong; Liu, Yong-Chun; Xiao, Yun-Feng

    2015-04-01

    We study Raman scattering of single nanoparticles coupled to a high-Q whispering-gallery microresonator. It is found that cavity resonances greatly enhance the Raman signal, and the enhancement factor is as high as 108. Unlike the noncavity case, the signal power exhibits a nonmonotonic dependence on particle size, and it reaches the maximum when the Rayleigh scattering loss and the cavity intrinsic loss are comparable. We further analyze how the Raman signal intensity is influenced by different parameters including cavity quality factors and taper-cavity coupling strength. The detection limit of observing single-nanoparticle Raman signal is discussed finally. As a potential application, this mechanism may provide an alternative way to detect specific biological targets without the need of precovered biorecognitions.

  7. Development of a Body Shield for Small Animal PET System to Reduce Random and Scatter Coincidences

    NASA Astrophysics Data System (ADS)

    Wada, Yasuhiro; Yamamoto, Seiichi; Watanabe, Yasuyoshi

    2015-02-01

    For small animal positron emission tomography (PET) research using high radioactivity, such as dynamic studies, the resulting high random coincidence rate of the system degrades image quality. The random coincidence rate is increased not only by the gamma photons from inside the axial-field-of-view (axial-FOV) of the PET system but also by those from outside the axial-FOV. For brain imaging in small animal studies, significant interference is observed from gamma photons emitted from the body. Single gamma photons from the body enter the axial-FOV and increase the random and scatter coincidences. Shielding against the gamma photons from outside the axial-FOV would improve the image quality. For this purpose, we developed a body shield for a small animal PET system, the microPET Primate 4-ring system, and evaluated its performance. The body shield is made of 9-mm-thick lead and it surrounds most of a rat's body. We evaluated the effectiveness of the body shield using a head phantom and a body phantom with a radioactivity concentration ratio of 1:2 and a maximum total activity of approximately 250 MBq. The random coincidence rate was dramatically decreased to 1/10, and the noise equivalent count rate (NECR) was increased 6 times with an activity of 7 MBq in the head phantom. The true count rate was increased to 35% due to the decrease in system deadtime. The average scatter fraction was decreased to 1/2.5 with the body shield. Count rate measurements of rat were also conducted with an injection activity of approximately 25 MBq of [C-11]N,N-dimethyl-2-(2-amino-4-cyanophenylthio) benzylamine ([C-11]DASB) and approximately 70 and 310 MBq of 2-deoxy-2-(F-18)fluoro-D-glucose ([F-18]FDG). Using the body shield, [F-18]FDG images of rats were improved by increasing the amount of radioactivity injected. The body shield designed for small animal PET systems is a promising tool for improving image quality and quantitation accuracy in small animal molecular imaging research.

  8. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    NASA Astrophysics Data System (ADS)

    Chytyk-Praznik, Krista Joy

    Radiation therapy is continuously increasing in complexity due to technological innovation in delivery techniques, necessitating thorough dosimetric verification. Comparing accurately predicted portal dose images to measured images obtained during patient treatment can determine if a particular treatment was delivered correctly. The goal of this thesis was to create a method to predict portal dose images that was versatile and accurate enough to use in a clinical setting. All measured images in this work were obtained with an amorphous silicon electronic portal imaging device (a-Si EPID), but the technique is applicable to any planar imager. A detailed, physics-motivated fluence model was developed to characterize fluence exiting the linear accelerator head. The model was further refined using results from Monte Carlo simulations and schematics of the linear accelerator. The fluence incident on the EPID was converted to a portal dose image through a superposition of Monte Carlo-generated, monoenergetic dose kernels specific to the a-Si EPID. Predictions of clinical IMRT fields with no patient present agreed with measured portal dose images within 3% and 3 mm. The dose kernels were applied ignoring the geometrically divergent nature of incident fluence on the EPID. A computational investigation into this parallel dose kernel assumption determined its validity under clinically relevant situations. Introducing a patient or phantom into the beam required the portal image prediction algorithm to account for patient scatter and attenuation. Primary fluence was calculated by attenuating raylines cast through the patient CT dataset, while scatter fluence was determined through the superposition of pre-calculated scatter fluence kernels. Total dose in the EPID was calculated by convolving the total predicted incident fluence with the EPID-specific dose kernels. The algorithm was tested on water slabs with square fields, agreeing with measurement within 3% and 3 mm. The method was then applied to five prostate and six head-and-neck IMRT treatment courses (˜1900 clinical images). Deviations between the predicted and measured images were quantified. The portal dose image prediction model developed in this thesis work has been shown to be accurate, and it was demonstrated to be able to verify patients' delivered radiation treatments.

  9. Head and neck cancer patients' experiences of percutaneous endoscopic gastrostomy feeding: a Q-methodology study.

    PubMed

    Merrick, S; Farrell, D

    2012-07-01

    Head and neck cancer patients are at high risk of malnutrition and its complications and therefore often undergo non-oral nasogastric or percutaneous endoscopic gastrostomy (PEG) nutrition support. However, there is little evidence that either approach is effective in this group. While one possible explanation for these findings relates to the relationship between artificial tube feeding and poor quality of life, there is little research that examines the patient's subjective experience of nutrition support. This study investigated the experiences of PEG tube feeding in head and neck cancer patients undergoing radical treatment. Conventional Q-methodology was used with 15 head and neck cancer patients, who rank-ordered 36 statements according to the extent to which these reflected their experiences of PEG tube feeding. The sorted statements were factor-analysed case-wise to provide clusters of similar experiences. Three perspectives emerged. Factor 1, labelled 'Constructive cognitive appraisal', focused around positive adaptation to, and acceptance of, PEG feeding. Factor 2, labelled 'Cognitive-affective dissonance', reflected ambivalence between cognitive acceptance and affective rejection of the PEG tube. Factor 3, labelled 'Emotion-focused appraisal', was characterised by tube-focused anxiety and fear. The findings broadly confirm Levanthal et al.'s Self-Regulatory Model of coping and support the need for genuine and individualised patient-centred nutritional care. © 2012 Blackwell Publishing Ltd.

  10. SU-F-T-207: Does the Greater Flexibility of Pencil Beam Scanning Reduce the Need for a Proton Gantry?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, S; Depauw, N; Flanz, J

    2016-06-15

    Purpose: Gantry-less proton treatment facility could lower the capital cost of proton therapy. This study investigates the dosimetric feasibility of using only coplanar pencil beam scanning (PBS) beams for those patients who had beam angles that would not have been deliverable without the gantry. Those coplanar beams are implemented on gantry-less horizontal beam-line with patients in sitting or standing positions. Methods: We have selected ten patients (seven head-and-neck, one thoracic, one abdominal and one pelvic case) with clinically delivered double scattering (DS) or PBS treatment plans with beam angles that were challenging to achieve without a gantry. After removing thesemore » beams angles, PBS plans were optimized for gantry-less intensity modulated proton therapy (IMPT) or single field optimization (SFO) with multi-criteria optimization (MCO). For head-and-neck patients who were treated by DS, we generated PBS plans with non-coplanar beams for comparison. Dose-volume-histograms (DVHs), target homogeneity index (HI), mean dose, D-2 and D-98 were reported. Robustness analysis was performed with ±2.5 mm setup errors and ±3.5% range uncertainties for three head-and-neck patients. Results: PBS-gantry-less plans provided more homogenous target coverage and significant improvements on organs-at-risk (OARs) sparing, compared to passive scattering treatments with a gantry. The PBS gantry-less treatments reduced the HI for target coverage by 1.3% to 47.2%, except for a suprasellar patient and a liver patient. The PBS-gantry-less plans reduced the D-mean of OARs by 3.6% to 67.4%. The PBS-gantry plans had similar target coverage and only marginal improvements on OAR sparing as compared to the PBS-gantry-less plans. These two PBS plans also had similar robustness relative to range uncertainties and setup errors. Conclusion: The gantry-less plans have with less mean dose to OARs and more homogeneous target coverage. Although the PBS-gantry plans have slightly improved target coverage and OARs sparing, the overall benefit of having a gantry to provide non-coplanar beams is debatable.« less

  11. Reassessment of the Necessity of the Proton Gantry: Analysis of Beam Orientations From 4332 Treatments at the Massachusetts General Hospital Proton Center Over the Past 10 Years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Susu, E-mail: syan5@mgh.harvard.edu; Lu, Hsiao-Ming; Flanz, Jay

    2016-05-01

    Purpose: To retrospectively analyze the beam approaches used in gantry-based proton treatments, and to reassess the practical advantages of the gantry, compared with beam approaches that are achievable without a gantry, in the context of present-day technology. Methods and Materials: We reviewed the proton therapy plans of 4332 patients treated on gantries at our hospital, delivered by the double scattering technique (n=4228) and, more recently, pencil beam scanning (PBS) (n=104). Beam approaches, relative to the patient frame, were analyzed individually to identify cases that could be treated without a gantry. Three treatment configurations were considered, with the patient in lying position,more » sitting position, or both. The FIXED geometry includes a fixed horizontal portal. The BEND geometry enables a limited vertical inflection of the beam by up to 20°. The MOVE geometry allows for flexibility of the patient head and body setup. Results: The percentage of patients with head and neck tumors that could be treated without a gantry using double scattering was 44% in FIXED, 70% in 20° BEND, and 100% in 90° MOVE. For torso regions, 99% of patients could be treated in 20° BEND. Of 104 PBS treatments, all but 1 could be reproduced with FIXED geometry. The only exception would require a 10° BEND capability. Note here that the PBS treatments were applied to select anatomic sites, including only 2 patients with skull-base tumors. Conclusions: The majority of practical beam approaches can be realized with gantry-less delivery, aided by limited beam bending and patient movements. Practical limitations of the MOVE geometry, and treatments requiring a combination of lying and sitting positions, may lower the percentage of head and neck patients who could be treated without a gantry. Further investigation into planning, immobilization, and imaging is needed to remove the practical limitations and to facilitate proton treatment without a gantry.« less

  12. Measurements of ionic structure in shock compressed lithium hydride from ultrafast x-ray Thomson scattering.

    PubMed

    Kritcher, A L; Neumayer, P; Brown, C R D; Davis, P; Döppner, T; Falcone, R W; Gericke, D O; Gregori, G; Holst, B; Landen, O L; Lee, H J; Morse, E C; Pelka, A; Redmer, R; Roth, M; Vorberger, J; Wünsch, K; Glenzer, S H

    2009-12-11

    We present the first ultrafast temporally, spectrally, and angularly resolved x-ray scattering measurements from shock-compressed matter. The experimental spectra yield the absolute elastic and inelastic scattering intensities from the measured density of free electrons. Laser-compressed lithium-hydride samples are well characterized by inelastic Compton and plasmon scattering of a K-alpha x-ray probe providing independent measurements of temperature and density. The data show excellent agreement with the total intensity and structure when using the two-species form factor and accounting for the screening of ion-ion interactions.

  13. Optical absorption and scattering spectra of pathological stomach tissues

    NASA Astrophysics Data System (ADS)

    Giraev, K. M.; Ashurbekov, N. A.; Lakhina, M. A.

    2011-03-01

    Diffuse reflection spectra of biotissues in vivo and transmission and reflection coefficients for biotissues in vitro are measured over 300-800 nm. These data are used to determine the spectral absorption and scattering indices and the scattering anisotropy factor for stomach mucous membranes under normal and various pathological conditions (chronic atrophic and ulcerous defects, malignant neoplasms). The most importan tphysiological (hemodynamic and oxygenation levels) and structural-morphological (scatterer size and density) parameters are also determined. The results of a morphofunctional study correlate well with the optical properties and are consistent with data from a histomorphological analysis of the corresponding tissues.

  14. Lung cancer diagnosis with quantitative DIC microscopy and support vector machine

    NASA Astrophysics Data System (ADS)

    Zheng, Longfei; Cai, Shuangshuang; Zeng, Bixin; Xu, Min

    2017-01-01

    We report the study of lung squamous cell carcinoma diagnosis using the TI-DIC microscopy and the scattering-phase theorem. The spatially resolved optical properties of tissue are computed from the 2D phase map via the scattering-phase theorem. The scattering coefficient, the reduced scattering coefficient, and the anisotropy factor are all found to increase with the grade of lung cancer. The retrieved optical parameters are shown to distinguish cancer cases from the normal cases with high accuracy. This label-free microscopic approach applicable to fresh tissues may be promising for in situ rapid cancer diagnosis.

  15. The determinant of household tourism expenditure in Central Java Province, Indonesia

    NASA Astrophysics Data System (ADS)

    Subanti, S.; Respatiwulan; Hakim, A. R.; Handajani, S. S.; Hakim, I. M.

    2018-03-01

    The purpose of our paper want to determine the factors of household tourism expenditure in Central Java Province, Indonesia. This paper used ordinary least squares regression. The findings from this paper, (1) the significant factors that affecting household tourism expenditure are marital status, sex, household income per capita, education for head of household, education for member of household, number of household, urbanrural, and industrial origin for head of household; (2) For variables which have positive relationship with household tourism expenditure, the variable of marital status has a biggest value from others; and (3) For variables which have negative relationship with household tourism expenditure, the variable of industrial origin for head household has a biggest value from others.

  16. Headaches During War: Analysis of Presentation, Treatment, and Factors Associated with Outcome

    DTIC Science & Technology

    2011-01-01

    disorders, including head - ache , ranking fifth. By Vietnam, non-battle injuries had surpassed all other disease categories as the leading cause of unit...most typically occur without a physical inciting event but are more likely to be asso- ciated with trauma than tension-type or other head - aches ...of opioid therapy in otherwise healthy patients with refractory, chronic daily head - aches (34). There are several limitations to our study that need

  17. Exploding Head Syndrome in the Epilepsy Monitoring Unit: Case Report and Literature Review.

    PubMed

    Gillis, Kara; Ng, Marcus C

    2017-01-01

    Diagnosis of paroxysmal events in epilepsy patients is often made through video-telemetry electroencephalography in the epilepsy monitoring unit. This case report describes the first-ever diagnosis of exploding head syndrome in a patient with longstanding epilepsy and novel nocturnal events. In this report, we describe the presentation of exploding head syndrome and its prevalence and risk factors. In addition, the prevalence of newly diagnosed sleep disorders through video-telemetry electroencephalography in the epilepsy monitoring unit is briefly reviewed. This report also illustrates the novel use of clobazam for the treatment of exploding head syndrome.

  18. Positive Factors Influencing the Advancement of Women to the Role of Head Athletic Trainer in the National Collegiate Athletic Association Divisions II and III

    PubMed Central

    Mazerolle, Stephanie M.; Eason, Christianne M.

    2016-01-01

    Context:  Research suggests that women do not pursue leadership positions in athletic training due to a variety of reasons, including family challenges, organizational constraints, and reluctance to hold the position. The literature has been focused on the National Collegiate Athletic Association Division I setting, limiting our full understanding. Objective:  To examine factors that help women as they worked toward the position of head athletic trainer. Design:  Qualitative study. Setting:  Divisions II and III. Patients or Other Participants:  Seventy-seven women who were employed as head athletic trainers at the Division II or III level participated in our study. Participants were 38 ± 9 (range = 24−57) years old and had an average of 14 ± 8 (range = 1−33) years of athletic training experience. Data Collection and Analysis:  We conducted online interviews. Participants journaled their reflections to a series of open-ended questions pertaining to their experiences as head athletic trainers. Data were analyzed using a general inductive approach. Credibility was secured by peer review and researcher triangulation. Results:  Three organizational facilitators emerged from the data, workplace atmosphere, mentors, and past work experiences. These organizational factors were directly tied to aspects within the athletic trainer's employment setting that allowed her to enter the role. One individual-level facilitator was found: personal attributes that were described as helpful for women in transitioning to the role of the head athletic trainer. Participants discussed being leaders and persisting toward their career goals. Conclusions:  Women working in Divisions II and III experience similar facilitators to assuming the role of head athletic trainer as those working in the Division I setting. Divisions II and III were viewed as more favorable for women seeking the role of head athletic trainer, but like those in the role in the Division I setting, women must have leadership skills. PMID:27529359

  19. Exploring the effects of roadway characteristics on the frequency and severity of head-on crashes: case studies from Malaysian federal roads.

    PubMed

    Hosseinpour, Mehdi; Yahaya, Ahmad Shukri; Sadullah, Ahmad Farhan

    2014-01-01

    Head-on crashes are among the most severe collision types and of great concern to road safety authorities. Therefore, it justifies more efforts to reduce both the frequency and severity of this collision type. To this end, it is necessary to first identify factors associating with the crash occurrence. This can be done by developing crash prediction models that relate crash outcomes to a set of contributing factors. This study intends to identify the factors affecting both the frequency and severity of head-on crashes that occurred on 448 segments of five federal roads in Malaysia. Data on road characteristics and crash history were collected on the study segments during a 4-year period between 2007 and 2010. The frequency of head-on crashes were fitted by developing and comparing seven count-data models including Poisson, standard negative binomial (NB), random-effect negative binomial, hurdle Poisson, hurdle negative binomial, zero-inflated Poisson, and zero-inflated negative binomial models. To model crash severity, a random-effect generalized ordered probit model (REGOPM) was used given a head-on crash had occurred. With respect to the crash frequency, the random-effect negative binomial (RENB) model was found to outperform the other models according to goodness of fit measures. Based on the results of the model, the variables horizontal curvature, terrain type, heavy-vehicle traffic, and access points were found to be positively related to the frequency of head-on crashes, while posted speed limit and shoulder width decreased the crash frequency. With regard to the crash severity, the results of REGOPM showed that horizontal curvature, paved shoulder width, terrain type, and side friction were associated with more severe crashes, whereas land use, access points, and presence of median reduced the probability of severe crashes. Based on the results of this study, some potential countermeasures were proposed to minimize the risk of head-on crashes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Context-specific function of the LIM homeobox 1 transcription factor in head formation of the mouse embryo.

    PubMed

    Fossat, Nicolas; Ip, Chi Kin; Jones, Vanessa J; Studdert, Joshua B; Khoo, Poh-Lynn; Lewis, Samara L; Power, Melinda; Tourle, Karin; Loebel, David A F; Kwan, Kin Ming; Behringer, Richard R; Tam, Patrick P L

    2015-06-01

    Lhx1 encodes a LIM homeobox transcription factor that is expressed in the primitive streak, mesoderm and anterior mesendoderm of the mouse embryo. Using a conditional Lhx1 flox mutation and three different Cre deleters, we demonstrated that LHX1 is required in the anterior mesendoderm, but not in the mesoderm, for formation of the head. LHX1 enables the morphogenetic movement of cells that accompanies the formation of the anterior mesendoderm, in part through regulation of Pcdh7 expression. LHX1 also regulates, in the anterior mesendoderm, the transcription of genes encoding negative regulators of WNT signalling, such as Dkk1, Hesx1, Cer1 and Gsc. Embryos carrying mutations in Pcdh7, generated using CRISPR-Cas9 technology, and embryos without Lhx1 function specifically in the anterior mesendoderm displayed head defects that partially phenocopied the truncation defects of Lhx1-null mutants. Therefore, disruption of Lhx1-dependent movement of the anterior mesendoderm cells and failure to modulate WNT signalling both resulted in the truncation of head structures. Compound mutants of Lhx1, Dkk1 and Ctnnb1 show an enhanced head truncation phenotype, pointing to a functional link between LHX1 transcriptional activity and the regulation of WNT signalling. Collectively, these results provide comprehensive insight into the context-specific function of LHX1 in head formation: LHX1 enables the formation of the anterior mesendoderm that is instrumental for mediating the inductive interaction with the anterior neuroectoderm and LHX1 also regulates the expression of factors in the signalling cascade that modulate the level of WNT activity. © 2015. Published by The Company of Biologists Ltd.

  1. Role of human papillomavirus and its detection in potentially malignant and malignant head and neck lesions: updated review.

    PubMed

    Chaudhary, Ajay Kumar; Singh, Mamta; Sundaram, Shanthy; Mehrotra, Ravi

    2009-06-25

    Head and neck malignancies are characterized by a multiphasic and multifactorial etiopathogenesis. Tobacco and alcohol consumption are the most common risk factors for head and neck malignancy. Other factors, including DNA viruses, especially human papilloma virus (HPV), may also play a role in the initiation or development of these lesions. The pathways of HPV transmission in the head and neck mucosal lesions include oral-genital contact, more than one sexual partner and perinatal transmission of HPV to the neonatal child. The increase in prevalence of HPV infection in these lesions may be due to wider acceptance of oral sex among teenagers and adults as this is perceived to be a form of safe sex. The prevalence of HPV in benign lesions as well as malignancies has been assessed by many techniques. Among these, the polymerase chain reaction is the most sensitive method. Review of literature reveals that HPV may be a risk factor for malignancies, but not in all cases. For confirmation of the role of HPV in head and neck squamous cell carcinoma, large population studies are necessary in an assortment of clinical settings. Prophylactic vaccination against high-risk HPV types eventually may prevent a significant number of cervical carcinomas. Of the two vaccines currently available, Gardasil (Merck & Co., Inc.) protects against HPV types 6, 11, 16 and 18, while the other vaccine, Cervarix (GlaxoSmithKline, Rixensart, Belgium) protects against HPV types 16 and 18 only. However, the HPV vaccine has, to the best of our knowledge, not been tried in head and neck carcinoma. The role of HPV in etiopathogenesis, prevalence in benign and malignant lesions of this area and vaccination strategies are briefly reviewed here.

  2. Vestibulo-ocular reflex gain values in the suppression head impulse test of healthy subjects.

    PubMed

    Rey-Martinez, Jorge; Thomas-Arrizabalaga, Izaskun; Espinosa-Sanchez, Juan Manuel; Batuecas-Caletrio, Angel; Trinidad-Ruiz, Gabriel; Matiño-Soler, Eusebi; Perez-Fernandez, Nicolas

    2018-02-15

    To assess whether there are differences in vestibulo-ocular reflex (VOR) gain for suppression head impulse (SHIMP) and head impulse (HIMP) video head impulse test paradigms, and if so, what are their causes. Prospective multicenter observational double-blind nonrandomized clinical study was performed by collecting 80 healthy subjects from four reference hospitals. SHIMP data was postprocessed to eliminate impulses in which early SHIMP saccades were detected. Differences between HIMP and SHIMP VOR gain values were statistically evaluated. Head impulse maximum velocity, gender, age, direction of impulse, and hospital center were considered as possible influential factors. A small significant statistical difference between HIMP and SHIMP VOR gain values was found on repeated measures analysis of variance (-0.05 ± 0.006, P < 0.001). Optimized linear model showed a significant influence of age variable on the observed differences for HIMP and SHIMP gain values and did not find influence between gain values differences and maximum head impulse velocity. Both HIMP and SHIMP VOR gain values were significant lower (-0.09, P < 0.001) when the impulses were performed to the left side. We had observed a difference in SHIMP and HIMP gain values not adequately explained by known gain modification factors. The persistence of this slight but significant difference indicates that there are more factors causing lower SHIMP VOR gain values. This difference must to be considered in further studies as well as in the clinical SHIMP testing protocols. We hypothesized that VOR phasic response inhibition could be the underlying cause of this difference. IIb. Laryngoscope, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Prevalence of Head Lice Infestation and Its Associated Factors among Primary School Students in Iran: A Systematic Review and Meta-analysis.

    PubMed

    Moosazadeh, Mahmood; Afshari, Mahdi; Keianian, Hormoz; Nezammahalleh, Asghar; Enayati, Ahmad Ali

    2015-12-01

    Head lice infestation is one of the most important health problems, generally involving children aged 5-13 years. This study aims to estimate the prevalence of head lice infestation and its associated factors among primary school children using systematic review and meta-analysis methods. Different national and international databases were searched for selecting the relevant studies using appropriate keywords, Medical Subject Heading terms, and references. Relevant studies with acceptable quality for meta-analysis were selected having excluded duplicate and irrelevant articles, quality assessment, and application of inclusion/exclusion criteria. With calculating standard errors according to binomial distribution and also considering the Cochrane's Q test as well as I-squared index for heterogeneity, pediculosis prevalence rate was estimated using Stata SE V.11 software. Forty studies met the inclusion criteria of this review and entered into the meta-analysis including 200,306 individuals. Using a random effect model, the prevalence (95% confidence interval) of head lice infestation among primary school children was estimated as 1.6% (1.2-2.05), 8.8% (7.6-9.9), and 7.4% (6.6-8.2) for boys, girls, and all the students, respectively. The infestation rate was found to be associated with low educational level of parents, long hair, family size, mother's job (housewife), father's job (worker/unemployed), using a common comb, lack of bathrooms in the house, and a low frequency of bathing. This meta-analysis revealed that the prevalence of head lice infestation among Iranian primary school children is relatively high with more prevalence among girls. We also found that economic, social, cultural, behavioral, and hygienic factors are associated with this infestation.

  4. Exclusive Reactions at High Momentum Transfer

    NASA Astrophysics Data System (ADS)

    Radyushkin, Anatoly; Stoler, Paul

    2008-03-01

    Hard exclusive scattering at JLab / P. Kroll -- AdS/CFT and exclusive processes in QCD / S. J. Brodsky and G. F. de Téramond -- Hadron structure matters in collisions at high energy and momentum / A. W. Thomas -- Inclusive perspectives / P. Hoyer -- Fitting DVCS at NLO and beyond / K. Kumericki, D. Müller and K. Passek-Kumericki -- Spin-orbit correlations and single-spin asymmetries / M. Burkardt -- Electroproduction of soft pions at large momentum transfers / V. M. Braun, D. Yu. Ivanov and A. Peters -- Color transparency: 33 years and still running / M. Strikman -- Meson clouds and nucleon electromagnetic form factors / G. A. Miller -- Covariance, dynamics and symmetries, and hadron form factors / M. S. Bhagwat, I. C. Cloët and C. D. Roberts -- N to [symbol] electromagnetic and axial form factors in full QCD / C. Alexandrou -- Real and virtual compton scattering in perturbative QCD / C.-R. Ji and R. Thomson -- Deeply virtual compton scattering at Jefferson Lab / F. Sabatie -- DVCS at HERMES: recent results / F. Ellinghaus -- Deeply virtual compton scattering with CLAS / F. X. Girod -- Deeply virtual compton scattering off the neutron at JLab Hall A / M. Mazouz -- The future DVCS experiments in Hall A at JLab / J. Roche -- Deeply virtual compton scattering with CLAS12 / L. Elouadrhiri -- Quark helicity flip and the transverse spin dependence of inclusive DIS / A. Afanasev, M. Strikman and C. Weiss -- Deeply virtual pseudoscalar meson production / V. Kubarovsky and P. Stoler -- Exclusive p[symbol] electroproduction on the proton: GPDs or not GPDs? / M. Guidal and S. Morrow -- p[symbol] transverse target spin asymmetry at HERMES / A. Airapetian -- Electroproduction of ø(1020) mesons / J. P. Santoro and E. S. Smith -- Generalized parton distributions from hadronic observables / S. Ahmad ... [et al.] -- Imaging the proton via hard exclusive production in diffractive pp scattering / G. E. Hyde ... [et al.] -- Regge contributions to exclusive electro-production / A. P. Szczepaniak and J. T. Londergan -- High energy break-up of few-nucleon systems / M. Sargsian -- Photodisintegration of the deuteron, and [symbol]He / R. Gilman -- A review of the few-body form factors / G. G. Petratos -- Nucleon form factor measurements and interpretation / C. F. Perdrisat -- Implications of G[symbol](Q[symbol])/G[symbol](Q[symbol]) / S. Dubnicka and A. Z. Dubnickova -- High Q[symbol] large acceptance G[symbol]/G[symbol] measurements using polarization transfer / L. Pentchev, C. F. Perdrisat and B. Wojtsekhowski -- A precise measurement of the neutron magnetic form factor G[symbol] in the few-GeV[symbol] region / G. P. Gilfoyle et al. (the CLAS collaboration) -- Magnetic form factor of the neutron up to 8 (GeV/c)[symbol] / B. Quinn -- Timelike form factors / K. K. Seth -- Polarization phenomena in e[symbol]e[symbol] [symbol] pp¯ revisited / A. Z. Dubnickova and S. Dubnicka -- Light-cone sum rules for form factors of the N[symbol] transition at Q[symbol] = 0 / J. Rohrwild -- Exclusive electroproduction of [symbol] mesons / A. N. Villano (for the JLab E01-002 collaboration) -- Exclusive electroproduction of [symbol] mesons in the S[symbol](1535) resonance region at high momentum transfer / M. M. Dalton (for the JLab E01-002 collaboration) -- Two-photon exchange in electron-proton elastic scattering: theory update / A. V. Afanasev -- Two-photon exchange contributions to elastic ep scattering in the non-local field formalism / P. Jain, S. D. Joglekar and S. Mitra -- Beyond the born approximation: a precise comparison of positron-proton and electron-proton elastic scattering in CLAS / J. Lachniet et al. -- Meson form factors in the space-like region / D. Gaskell -- Pion-nucleon distribution amplitudes / A. Peters -- [symbol] scattering in the 1/N[symbol] expansion / H. J. Kwee -- [symbol] annihilations into quasi-two-body final states at 10.58 GeV / Kai Yi -- Transition distribution amplitudes / J. P. Lansberg, B. Pire and L. Szymanowski -- Novel QCD effects from initial and final state interactions / S. J. Brodsky -- Parton distributions and spin-orbital correlations / F. Yuan -- Transverse momentum dependences of distribution and fragmentation functions / D. S. Hwang and D. S. Kim -- Flavor dependence of the Boer-Mulders function and its influence on Azimuthal and single-spin asymmetries in semi-inclusive DIS / L. P. Gamberg, G. R. Goldstein and M. Schlegel -- Symmetric spin-dependent structure function in deep inelastic processes / D. S. Hwang, J. H. Kim and S. Kim -- HERMES recoil detector / R. Perez-Benito -- Inner calorimeter in CLAS/DVCS experiment / R. Niyazov -- Frozen-spin HD as a possible target for electro-production experiments / A. M. Sandorfi et al.

  5. Prevalence and risk factors of depressive disorder in caregivers of patients with head and neck cancer.

    PubMed

    Lee, Yu; Lin, Pao-Yen; Chien, Chih-Yen; Fang, Fu-Min

    2015-02-01

    The purpose of this study is to examine the prevalence and risk factors of depressive disorder in caregivers of patients with head and neck cancer. Study subjects were recruited from a multidisciplinary outpatient clinic for head and neck cancer in a medical center from February to July 2012. Caregivers of patients with head and neck cancer were enrolled and assessed using the Structured Clinical Interview for the DSM-IV, Clinician Version, the Short Form 36 Health Survey, and the Family APGAR index. The main aim of the study was to examine the difference in demographic data and clinical characteristics between the caregivers with and without depressive disorders. In addition, a stepwise forward model of logistic regression was used to test the possible risk factors. One hundred and forty-three caregivers were included in the study. The most prevalent psychiatric disorder was depressive disorder (14.7%), followed by adjustment disorder (13.3%). Nearly one-third of the caregivers had a psychiatric diagnosis. By using logistic regression analysis, it was found that unemployment (odds ratio (OR) = 3.16; 95% CI, 1.04-9.68), lower social functioning (OR = 1.43; 95% CI, 1.18-1.72), and lower educational level (OR = 1.16; 95% CI, 1.01-1.34) were significant risk factors for the depressive disorder. The clinical implication of our results is the value of using the standardized structured interview for early diagnosis of depressive disorder in caregivers of head and neck cancer patients. Early screening and management of depression in these caregivers will raise their quality of life and capability to care patients. Copyright © 2014 John Wiley & Sons, Ltd.

  6. A Surrogate for Debye-Waller Factors from Dynamic Stokes Shifts

    PubMed Central

    Zhong, Qin; Johnson, Jerainne; Aamer, Khaled A.; Tyagi, Madhusudan

    2011-01-01

    We show that the short-time behavior of time-resolved fluorescence Stokes shifts (TRSS) are similar to that of the intermediate scattering function obtained from neutron scattering at q near the peak in the static structure factor for glycerol. This allows us to extract a Debye-Waller (DW) factor analog from TRSS data at times as short as 1 ps in a relatively simple way. Using the time-domain relaxation data obtained by this method we show that DW factors evaluated at times ≥ 40 ps can be directly influenced by α relaxation and thus should be used with caution when evaluating relationships between fast and slow dynamics in glassforming systems. PMID:21701673

  7. Epidemiology of neurodegeneration in American-style professional football players

    PubMed Central

    2013-01-01

    The purpose of this article is to review the history of head injuries in relation to American-style football play, summarize recent research that has linked football head injuries to neurodegeneration, and provide a discussion of the next steps for refining the examination of neurodegeneration in football players. For most of the history of football, the focus of media reports and scientific studies on football-related head injuries was on the acute or short-term effects of serious, traumatic head injuries. Beginning about 10 years ago, a growing concern developed among neurologists and researchers about the long-term effects that playing professional football has on the neurologic health of the players. Autopsy-based studies identified a pathologically distinct neurodegenerative disorder, chronic traumatic encephalopathy, among athletes who were known to have experienced concussive and subconcussive blows to the head during their playing careers. Football players have been well represented in these autopsy findings. A mortality study of a large cohort of retired professional football players found a significantly increased risk of death from neurodegeneration. Further analysis found that non-line players were at higher risk than line players, possibly because of an increased risk of concussion. Although the results of the studies reviewed do not establish a cause effect relationship between football-related head injury and neurodegenerative disorders, a growing body of research supports the hypothesis that professional football players are at an increased risk of neurodegeneration. Significant progress has been made in the last few years on detecting and defining the pathology of neurodegenerative diseases. However, less progress has been made on other factors related to the progression of those diseases in football players. This review identifies three areas for further research: (a) quantification of exposure - a consensus is needed on the use of clinically practical measurements of blows to the head among football players; (b) genetic susceptibility factors - a more rigorous set of unbiased epidemiological and clinical studies is needed before any causal relationships can be drawn between suspected genetic factors, head injury, and neurodegeneration; and (c) earlier detection and prevention of neurodegenerative diseases. PMID:23876143

  8. Epidemiology of neurodegeneration in American-style professional football players.

    PubMed

    Lehman, Everett J

    2013-01-01

    The purpose of this article is to review the history of head injuries in relation to American-style football play, summarize recent research that has linked football head injuries to neurodegeneration, and provide a discussion of the next steps for refining the examination of neurodegeneration in football players. For most of the history of football, the focus of media reports and scientific studies on football-related head injuries was on the acute or short-term effects of serious, traumatic head injuries. Beginning about 10 years ago, a growing concern developed among neurologists and researchers about the long-term effects that playing professional football has on the neurologic health of the players. Autopsy-based studies identified a pathologically distinct neurodegenerative disorder, chronic traumatic encephalopathy, among athletes who were known to have experienced concussive and subconcussive blows to the head during their playing careers. Football players have been well represented in these autopsy findings. A mortality study of a large cohort of retired professional football players found a significantly increased risk of death from neurodegeneration. Further analysis found that non-line players were at higher risk than line players, possibly because of an increased risk of concussion. Although the results of the studies reviewed do not establish a cause effect relationship between football-related head injury and neurodegenerative disorders, a growing body of research supports the hypothesis that professional football players are at an increased risk of neurodegeneration. Significant progress has been made in the last few years on detecting and defining the pathology of neurodegenerative diseases. However, less progress has been made on other factors related to the progression of those diseases in football players. This review identifies three areas for further research: (a) quantification of exposure - a consensus is needed on the use of clinically practical measurements of blows to the head among football players; (b) genetic susceptibility factors - a more rigorous set of unbiased epidemiological and clinical studies is needed before any causal relationships can be drawn between suspected genetic factors, head injury, and neurodegeneration; and (c) earlier detection and prevention of neurodegenerative diseases.

  9. CMT for biomedical and other applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spanne, P.

    This session includes two presentations describing applications for x-ray tomography using synchrotron radiation for biomedical uses and fluid flow modeling, and outlines advantages for using monoenergetic x-rays. Contrast mechanisms are briefly described and several graphs of absorbed doses and scattering of x-rays are included. Also presented are schematic diagrams of computerized tomographic instrumentation with camera head. A brief description of goals for a real time tomographic system and expected improvements to the system are described. Color photomicrographs of the Berea Sandstone and human bone are provided, as well as a 3-D microtomographic reconstruction of a human vertebra sample.

  10. Sexual dimorphism of head morphology in three-spined stickleback Gasterosteus aculeatus.

    PubMed

    Aguirre, W E; Akinpelu, O

    2010-09-01

    This study examined sexual dimorphism of head morphology in the ecologically diverse three-spined stickleback Gasterosteus aculeatus. Male G. aculeatus had longer heads than female G. aculeatus in all 10 anadromous, stream and lake populations examined, and head length growth rates were significantly higher in males in half of the populations sampled, indicating that differences in head size increased with body size in many populations. Despite consistently larger heads in males, there was significant variation in size-adjusted head length among populations, suggesting that the relationship between head length and body length was flexible. Inter-population differences in head length were correlated between sexes, thus population-level factors influenced head length in both sexes despite the sexual dimorphism present. Head shape variation between lake and anadromous populations was greater than that between sexes. The common divergence in head shape between sexes across populations was about twice as important as the sexual dimorphism unique to each population. Finally, much of the sexual dimorphism in head length was due to divergence in the anterior region of the head, where the primary trophic structures were found. It is unclear whether the sexual dimorphism was due to natural selection for niche divergence between sexes or sexual selection. This study improves knowledge of the magnitude, growth rate divergence, inter-population variation and location of sexual dimorphism in G. aculeatus head morphology. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  11. Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality.

    PubMed

    Huda, Walter; Lieberman, Kristin A; Chang, Jack; Roskopf, Marsha L

    2004-03-01

    We investigated how patient head characteristics, as well as the choice of x-ray technique factors, affect lesion contrast and noise values in computed tomography (CT) images. Head sizes and mean Hounsfield unit (HU) values were obtained from head CT images for five classes of patients ranging from the newborn to adults. X-ray spectra with tube voltages ranging from 80 to 140 kV were used to compute the average photon energy, and energy fluence, transmitted through the heads of patients of varying size. Image contrast, and the corresponding contrast to noise ratios (CNRs), were determined for lesions of fat, muscle, and iodine relative to a uniform water background. Maintaining a constant image CNR for each lesion, the patient energy imparted was also computed to identify the x-ray tube voltage that minimized the radiation dose. For adults, increasing the tube voltage from 80 to 140 kV changed the iodine HU from 2.62 x 10(5) to 1.27 x 10(5), the fat HU from -138 to -108, and the muscle HU from 37.1 to 33.0. Increasing the x-ray tube voltage from 80 to 140 kV increased the percentage energy fluence transmission by up to a factor of 2. For a fixed x-ray tube voltage, the percentage transmitted energy fluence in adults was more than a factor of 4 lower than for newborns. For adults, increasing the x-ray tube voltage from 80 to 140 kV improved the CNR for muscle lesions by 130%, for fat lesions by a factor of 2, and for iodine lesions by 25%. As the size of the patient increased from newborn to adults, lesion CNR was reduced by about a factor of 2. The mAs value can be reduced by 80% when scanning newborns while maintaining the same lesion CNR as for adults. Maintaining the CNR of an iodine lesion at a constant level, use of 140 kV increases the energy imparted to an adult patient by nearly a factor of 3.5 in comparison to 80 kV. For fat and muscle lesions, raising the x-ray tube voltage from 80 to 140 kV at a constant CNR increased the patient dose by 37% and 7%, respectively. Our two key findings are that for head CT examinations performed at a constant CNR, the mAs can be substantially reduced when scanning infants, and that use of the lowest x-ray tube voltage will generally reduce patient doses.

  12. A review of head-worn display research at NASA Langley Research Center

    NASA Astrophysics Data System (ADS)

    Arthur, Jarvis J.; Bailey, Randall E.; Williams, Steven P.; Prinzel, Lawrence J.; Shelton, Kevin J.; Jones, Denise R.; Houston, Vincent

    2015-05-01

    NASA Langley has conducted research in the area of helmet-mounted/head-worn displays over the past 30 years. Initially, NASA Langley's research focused on military applications, but recently has conducted a line of research in the area of head-worn displays for commercial and business aircraft. This work has revolved around numerous simulation experiments as well as flight tests to develop technology and data for industry and regulatory guidance. The paper summarizes the results of NASA's helmet-mounted/head-worn display research. Of note, the work tracks progress in wearable collimated optics, head tracking, latency reduction, and weight. The research lends credence that a small, sunglasses-type form factor of the head-worn display would be acceptable to commercial pilots, and this goal is now becoming technologically feasible. The research further suggests that a head-worn display may serve as an "equivalent" Head-Up Display (HUD) with safety, operational, and cost benefits. "HUD equivalence" appears to be the economic avenue by which head-worn displays can become main-stream on the commercial and business aircraft flight deck. If this happens, NASA's research suggests that additional operational benefits using the unique capabilities of the head-worn display can open up new operational paradigms.

  13. Tunneling effects in resonant acoustic scattering of an air bubble in unbounded water.

    PubMed

    Simão, André G; Guimarães, Luiz G

    2016-01-01

    The problem of acoustic scattering of a gaseous spherical bubble immersed within unbounded liquid surrounding is considered in this work. The theory of partial wave expansion related to this problem is revisited. A physical model based on the analogy between acoustic scattering and potential scattering in quantum mechanics is proposed to describe and interpret the acoustical natural oscillation modes of the bubble, namely, the resonances. In this context, a physical model is devised in order to describe the air water interface and the implications of the high density contrast on the various regimes of the scattering resonances. The main results are presented in terms of resonance lifetime periods and quality factors. The explicit numerical calculations are undertaken through an asymptotic analysis considering typical bubble dimensions and underwater sound wavelengths. It is shown that the resonance periods are scaled according to the Minnaert's period, which is the short lived resonance mode, called breathing mode of the bubble. As expected, resonances with longer lifetimes lead to impressive cavity quality Q-factor ranging from 1010 to 105. The present theoretical findings lead to a better understanding of the energy storage mechanism in a bubbly medium.

  14. Novel approach for calculating the charge carrier mobility and Hall factor for semiconductor materials

    NASA Astrophysics Data System (ADS)

    Colibaba, G. V.

    2018-06-01

    The additive Matthiessen's rule is the simplest and most widely used rule for the rapid experimental characterization and modeling of the charge carrier mobility. However, the error when using this rule can be higher than 40% and the contribution of the assumed additional scattering channels due to the difference between the experimental data and results calculated based on this rule can be misestimated by several times. In this study, a universal semi-additive equation is proposed for the total mobility and Hall factor, which is applicable to any quantity of scattering mechanisms, where it considers the energy dependence of the relaxation time and the error is 10-20 times lower compared with Matthiessen's rule. Calculations with accuracy of 99% are demonstrated for materials with polar-optical phonon, acoustic phonon via the piezoelectric potential, ionized, and neutral impurity scattering. The proposed method is extended to the deformation potential, dislocation, localized defect, alloy potential, and dipole scattering, for nondegenerate and partially degenerate materials.

  15. Influence of local-field corrections on Thomson scattering in collision-dominated two-component plasmas.

    PubMed

    Fortmann, Carsten; Wierling, August; Röpke, Gerd

    2010-02-01

    The dynamic structure factor, which determines the Thomson scattering spectrum, is calculated via an extended Mermin approach. It incorporates the dynamical collision frequency as well as the local-field correction factor. This allows to study systematically the impact of electron-ion collisions as well as electron-electron correlations due to degeneracy and short-range interaction on the characteristics of the Thomson scattering signal. As such, the plasmon dispersion and damping width is calculated for a two-component plasma, where the electron subsystem is completely degenerate. Strong deviations of the plasmon resonance position due to the electron-electron correlations are observed at increasing Brueckner parameters r(s). These results are of paramount importance for the interpretation of collective Thomson scattering spectra, as the determination of the free electron density from the plasmon resonance position requires a precise theory of the plasmon dispersion. Implications due to different approximations for the electron-electron correlation, i.e., different forms of the one-component local-field correction, are discussed.

  16. 45 CFR 1306.3 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Regulations Relating to Public Welfare (Continued) OFFICE OF HUMAN DEVELOPMENT SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES THE ADMINISTRATION FOR CHILDREN, YOUTH AND FAMILIES, HEAD START PROGRAM HEAD START... factor in the growth and development of the child. (k) Home visits means the visits made to a child's...

  17. Design and development of a Space Station proximity operations research and development mockup

    NASA Technical Reports Server (NTRS)

    Haines, Richard F.

    1986-01-01

    Proximity operations (Prox-Ops) on-orbit refers to all activities taking place within one km of the Space Station. Designing a Prox-Ops control station calls for a comprehensive systems approach which takes into account structural constraints, orbital dynamics including approach/departure flight paths, myriad human factors and other topics. This paper describes a reconfigurable full-scale mock-up of a Prox-Ops station constructed at Ames incorporating an array of windows (with dynamic star field, target vehicle(s), and head-up symbology), head-down perspective display of manned and unmanned vehicles, voice- actuated 'electronic checklist', computer-generated voice system, expert system (to help diagnose subsystem malfunctions), and other displays and controls. The facility is used for demonstrations of selected Prox-Ops approach scenarios, human factors research (work-load assessment, determining external vision envelope requirements, head-down and head-up symbology design, voice synthesis and recognition research, etc.) and development of engineering design guidelines for future module interiors.

  18. Aroma profile design of wine spirits: Multi-objective optimization using response surface methodology.

    PubMed

    Matias-Guiu, Pau; Rodríguez-Bencomo, Juan José; Pérez-Correa, José R; López, Francisco

    2018-04-15

    Developing new distillation strategies can help the spirits industry to improve quality, safety and process efficiency. Batch stills equipped with a packed column and an internal partial condenser are an innovative experimental system, allowing a fast and flexible management of the rectification. In this study, the impact of four factors (heart-cut volume, head-cut volume, pH and cooling flow rate of the internal partial condenser during the head-cut fraction) on 18 major volatile compounds of Muscat spirits was optimized using response surface methodology and desirability function approaches. Results have shown that high rectification at the beginning of the heart-cut enhances the overall positive aroma compounds of the product, reducing off-flavor compounds. In contrast, optimum levels of heart-cut volume, head-cut volume and pH factors varied depending on the process goal. Finally, three optimal operational conditions (head off-flavors reduction, flowery terpenic enhancement and fruity ester enhancement) were evaluated by chemical and sensory analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Exclusive QCD processes, quark-hadron duality, and the transition to perturbative QCD

    NASA Astrophysics Data System (ADS)

    Corianò, Claudio; Li, Hsiang-nan; Savkli, Cetin

    1998-07-01

    Experiments at CEBAF will scan the intermediate-energy region of the QCD dynamics for the nucleon form factors and for Compton Scattering. These experiments will definitely clarify the role of resummed perturbation theory and of quark-hadron duality (QCD sum rules) in this regime. With this perspective in mind, we review the factorization theorem of perturbative QCD for exclusive processes at intermediate energy scales, which embodies the transverse degrees of freedom of a parton and the Sudakov resummation of the corresponding large logarithms. We concentrate on the pion and proton electromagnetic form factors and on pion Compton scattering. New ingredients, such as the evolution of the pion wave function and the complete two-loop expression of the Sudakov factor, are included. The sensitivity of our predictions to the infrared cutoff for the Sudakov evolution is discussed. We also elaborate on QCD sum rule methods for Compton Scattering, which provide an alternative description of this process. We show that, by comparing the local duality analysis to resummed perturbation theory, it is possible to describe the transition of exclusive processes to perturbative QCD.

  20. Improving scattering layer through mixture of nanoporous spheres and nanoparticles in ZnO-based dye-sensitized solar cells.

    PubMed

    Kim, Chohui; Choi, Hongsik; Kim, Jae Ik; Lee, Sangheon; Kim, Jinhyun; Lee, Woojin; Hwang, Taehyun; Kang, Suji; Moon, Taeho; Park, Byungwoo

    2014-01-01

    A scattering layer is utilized by mixing nanoporous spheres and nanoparticles in ZnO-based dye-sensitized solar cells. Hundred-nanometer-sized ZnO spheres consisting of approximately 35-nm-sized nanoparticles provide not only effective light scattering but also a large surface area. Furthermore, ZnO nanoparticles are added to the scattering layer to facilitate charge transport and increase the surface area as filling up large voids. The mixed scattering layer of nanoparticles and nanoporous spheres on top of the nanoparticle-based electrode (bilayer geometry) improves solar cell efficiency by enhancing both the short-circuit current (J sc) and fill factor (FF), compared to the layer consisting of only nanoparticles or nanoporous spheres.

Top