Sample records for head stability control

  1. Pigeons (C. livia) Follow Their Head during Turning Flight: Head Stabilization Underlies the Visual Control of Flight.

    PubMed

    Ros, Ivo G; Biewener, Andrew A

    2017-01-01

    Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades), and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles.

  2. Pigeons (C. livia) Follow Their Head during Turning Flight: Head Stabilization Underlies the Visual Control of Flight

    PubMed Central

    Ros, Ivo G.; Biewener, Andrew A.

    2017-01-01

    Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades), and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles. PMID:29249929

  3. Head control: volitional aspects of rehabilitation training in patients with multiple sclerosis compared with healthy subjects.

    PubMed

    Cattaneo, Davide; Ferrarin, Maurizio; Frasson, William; Casiraghi, Anna

    2005-07-01

    To investigate the role of voluntary mechanisms and motor learning in head stability and the impact of longitudinal biofeedback training in head control. Crossover trial and single-subject research design. Neurorehabilitation research institute. Head stability during treadmill gait was measured in healthy subjects and patients with multiple sclerosis (MS). The experimental condition in which subjects walked on the treadmill was compared with that in which the head was voluntarily stabilized. In another experimental condition, augmented feedback of head displacement was provided by means of a laser mounted on the head that projected a laser beam on a screen. The motor learning was investigated with biofeedback training sessions. Positional feedback was represented by the laser beam, with subjects having to stabilize the beam while walking on the treadmill. Head angular oscillation in the sagittal and frontal planes. Results showed that on verbal request, healthy subjects and patients further stabilized the head during gait, especially in the sagittal plane. Short-term feedback of head displacement was no better than self-stabilization at improving head control. Conversely, the motor learning was evident in the rehabilitation protocol: after 10 to 15 training sessions, patients with MS showed a clinically relevant decrease of head angular oscillations. Voluntary mechanisms play a role in head stabilization during gait. Augmented biofeedback of head displacement may be effective in reducing head oscillations.

  4. Head eye co-ordination and gaze stability in subjects with persistent whiplash associated disorders.

    PubMed

    Treleaven, Julia; Jull, Gwendolen; Grip, Helena

    2011-06-01

    Symptoms of dizziness, unsteadiness and visual disturbances are frequent complaints in persons with persistent whiplash associated disorders. This study investigated eye, head co-ordination and gaze stability in subjects with persistent whiplash (n = 20) and asymptomatic controls (n = 20). Wireless motion sensors and electro-oculography were used to measure: head rotation during unconstrained head movement, head rotation during gaze stability and sequential head and eye movements. Ten control subjects participated in a repeatability study (two occasions one week apart). Between-day repeatability was acceptable (ICC > 0.6) for most measures. The whiplash group had significantly less maximal eye angle to the left, range of head movement during the gaze stability task and decreased velocity of head movement in head eye co-ordination and gaze stability tasks compared to the control group (p < 0.01). There were significant correlations (r > 0.55) between both unrestrained neck movement and neck pain and head movement and velocity in the whiplash group. Deficits in gaze stability and head eye co-ordination may be related to disturbed reflex activity associated with decreased head range of motion and/or neck pain. Further research is required to explore the mechanisms behind these deficits, the nature of changes over time and the tests' ability to measure change in response to rehabilitation. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  5. Space flight and neurovestibular adaptation

    NASA Technical Reports Server (NTRS)

    Reschke, M. F.; Bloomberg, J. J.; Harm, D. L.; Paloski, W. H.

    1994-01-01

    Space flight represents a form of sensory stimulus rearrangement requiring modification of established terrestrial response patterns through central reinterpretation. Evidence of sensory reinterpretation is manifested as postflight modifications of eye/head coordination, locomotor patterns, postural control strategies, and illusory perceptions of self or surround motion in conjunction with head movements. Under normal preflight conditions, the head is stabilized during locomotion, but immediately postflight reduced head stability, coupled with inappropriate eye/head coordination, results in modifications of gait. Postflight postural control exhibits increased dependence on vision which compensates for inappropriate interpretation of otolith and proprioceptive inputs. Eye movements compensatory for perceived self motion, rather than actual head movements have been observed postflight. Overall, the in-flight adaptive modification of head stabilization strategies, changes in head/eye coordination, illusionary motion, and postural control are maladaptive for a return to the terrestrial environment.

  6. Space flight and changes in spatial orientation

    NASA Technical Reports Server (NTRS)

    Reschke, Millard F.; Bloomberg, Jacob J.; Harm, Deborah L.; Paloski, William H.

    1992-01-01

    From a sensory point of view, space flight represents a form of stimulus rearrangement requiring modification of established terrestrial response patterns through central reinterpretation. Evidence of sensory reinterpretation is manifested as postflight modifications of eye/head coordination, locomotor patterns, postural control strategies, and illusory perceptions of self or surround motion in conjunction with head movements. Under normal preflight conditions, the head is stabilized during locomotion, but immediately postflight reduced head stability, coupled with inappropriate eye/head coordination, results in modifications of gait. Postflight postural control exhibits increased dependence on vision which compensates for inappropriate interpretation of otolith and proprioceptive inputs. Eye movements compensatory for perceived self motion, rather than actual head movements have been observed postflight. Overall, the in-flight adaptive modification of head stabilization strategies, changes in head/eye coordination, illusionary motion, and postural control are maladaptive for a return to the terrestrial environment. Appropriate countermeasures for long-duration flights will rely on preflight adaptation and in-flight training.

  7. Vestibular Dysfunction after Subconcussive Head Impact

    PubMed Central

    Ma, Lei; Kawata, Keisuke; Tierney, Ryan; Jeka, John J.

    2017-01-01

    Abstract Current thinking views mild head impact (i.e., subconcussion) as an underrecognized phenomenon that has the ability to cause significant current and future detrimental neurological effects. Repeated mild impacts to the head, however, often display no observable behavioral deficits based on standard clinical tests, which may lack sensitivity. The current study investigates the effects of subconcussive impacts from soccer heading with innovative measures of vestibular function and walking stability in a pre- 0–2 h, post- 24 h post-heading repeated measures design. The heading group (n = 10) executed 10 headers with soccer balls projected at a velocity of 25 mph (11.2 m/sec) over 10 min. Subjects were evaluated 24 h before, immediately after, and 24 h after soccer heading with: the modified Balance Error Scoring System (mBESS); a walking stability task with visual feedback of trunk movement; and galvanic vestibular stimulation (GVS) while standing with eyes closed on foam. A control group (n = 10) followed the same protocol with no heading. The results showed significant decrease in trunk angle, leg angle gain, and center of mass gain relative to GVS for the heading group compared with controls. Medial-lateral trunk orientation displacement and velocity during treadmill walking increased immediately after mild head impact for the heading group compared with controls. Controls showed an improvement in mBESS scores over time, indicating a learning effect, which was not observed with the heading group. These results suggest that mild head impact leads to a transient dysfunction in vestibular processing, which deters walking stability during task performance. PMID:26885560

  8. Vestibular Dysfunction after Subconcussive Head Impact.

    PubMed

    Hwang, Sungjae; Ma, Lei; Kawata, Keisuke; Tierney, Ryan; Jeka, John J

    2017-01-01

    Current thinking views mild head impact (i.e., subconcussion) as an underrecognized phenomenon that has the ability to cause significant current and future detrimental neurological effects. Repeated mild impacts to the head, however, often display no observable behavioral deficits based on standard clinical tests, which may lack sensitivity. The current study investigates the effects of subconcussive impacts from soccer heading with innovative measures of vestibular function and walking stability in a pre- 0-2 h, post- 24 h post-heading repeated measures design. The heading group (n = 10) executed 10 headers with soccer balls projected at a velocity of 25 mph (11.2 m/sec) over 10 min. Subjects were evaluated 24 h before, immediately after, and 24 h after soccer heading with: the modified Balance Error Scoring System (mBESS); a walking stability task with visual feedback of trunk movement; and galvanic vestibular stimulation (GVS) while standing with eyes closed on foam. A control group (n = 10) followed the same protocol with no heading. The results showed significant decrease in trunk angle, leg angle gain, and center of mass gain relative to GVS for the heading group compared with controls. Medial-lateral trunk orientation displacement and velocity during treadmill walking increased immediately after mild head impact for the heading group compared with controls. Controls showed an improvement in mBESS scores over time, indicating a learning effect, which was not observed with the heading group. These results suggest that mild head impact leads to a transient dysfunction in vestibular processing, which deters walking stability during task performance.

  9. Stability analysis of a run-of-river diversion hydropower plant with surge tank and spillway in the head pond.

    PubMed

    Sarasúa, José Ignacio; Elías, Paz; Martínez-Lucas, Guillermo; Pérez-Díaz, Juan Ignacio; Wilhelmi, José Román; Sánchez, José Ángel

    2014-01-01

    Run-of-river hydropower plants usually lack significant storage capacity; therefore, the more adequate control strategy would consist of keeping a constant water level at the intake pond in order to harness the maximum amount of energy from the river flow or to reduce the surface flooded in the head pond. In this paper, a standard PI control system of a run-of-river diversion hydropower plant with surge tank and a spillway in the head pond that evacuates part of the river flow plant is studied. A stability analysis based on the Routh-Hurwitz criterion is carried out and a practical criterion for tuning the gains of the PI controller is proposed. Conclusions about the head pond and surge tank areas are drawn from the stability analysis. Finally, this criterion is applied to a real hydropower plant in design state; the importance of considering the spillway dimensions and turbine characteristic curves for adequate tuning of the controller gains is highlighted.

  10. Stability Analysis of a Run-of-River Diversion Hydropower Plant with Surge Tank and Spillway in the Head Pond

    PubMed Central

    Sarasúa, José Ignacio; Elías, Paz; Wilhelmi, José Román; Sánchez, José Ángel

    2014-01-01

    Run-of-river hydropower plants usually lack significant storage capacity; therefore, the more adequate control strategy would consist of keeping a constant water level at the intake pond in order to harness the maximum amount of energy from the river flow or to reduce the surface flooded in the head pond. In this paper, a standard PI control system of a run-of-river diversion hydropower plant with surge tank and a spillway in the head pond that evacuates part of the river flow plant is studied. A stability analysis based on the Routh-Hurwitz criterion is carried out and a practical criterion for tuning the gains of the PI controller is proposed. Conclusions about the head pond and surge tank areas are drawn from the stability analysis. Finally, this criterion is applied to a real hydropower plant in design state; the importance of considering the spillway dimensions and turbine characteristic curves for adequate tuning of the controller gains is highlighted. PMID:25405237

  11. Locomotor skills and balance strategies in adolescents idiopathic scoliosis.

    PubMed

    Mallau, Sophie; Bollini, Gérard; Jouve, Jean-Luc; Assaiante, Christine

    2007-01-01

    Locomotor balance control assessment was performed to study the effect of idiopathic scoliosis on head-trunk coordination in 17 patients with adolescent idiopathic scoliosis (AIS) and 16 control subjects. The aim of this study was to explore the functional effects of structural spinal deformations like idiopathic scoliosis on the balance strategies used during locomotion. Up to now, the repercussion of the idiopathic scoliosis on head-trunk coordination and balance strategies during locomotion is relatively unknown. Seventeen patients with AIS (mean age 14 years 3 months, 10 degrees < Cobb angle > 30 degrees) and 16 control subjects (mean age 14 years 1 month) were tested during various locomotor tasks: walking on the ground, walking on a line, and walking on a beam. Balance control was examined in terms of rotation about the vertical axis (yaw) and on a frontal plane (roll). Kinematics of foot, pelvis, trunk, shoulder, and head rotations were measured with an automatic optical TV image processor in order to calculate angular dispersions and segmental stabilizations. Decreasing the walking speed is the main adaptive strategy used in response to balance problems in control subjects as well as patients with AIS. However, patients with AIS performed walking tasks more slowly than normal subjects (around 15%). Moreover, the pelvic stabilization is preserved, despite the structural changes affecting the spine. Lastly, the biomechanical defect resulting from idiopathic scoliosis mainly affects the yaw head stabilization during locomotion. Patients with AIS show substantial similarities with control subjects in adaptive strategies relative to locomotor velocity as well as balance control based on segmental stabilization. In contrast, the loss of the yaw head stabilization strategies, mainly based on the use of vestibular information, probably reflects the presence of vestibular deficits in the patients with AIS.

  12. Destabilization of Human Balance Control by Static and Dynamic Head Tilts

    NASA Technical Reports Server (NTRS)

    Paloski, William H.; Wood, Scott J.; Feiveson, Alan H.; Black, F. Owen; Hwang, Emma Y.; Reschke, Millard F.

    2004-01-01

    To better understand the effects of varying head movement frequencies on human balance control, 12 healthy adult humans were studied during static and dynamic (0.14,0.33,0.6 Hz) head tilts of +/-30deg in the pitch and roll planes. Postural sway was measured during upright stance with eyes closed and altered somatosensory inputs provided by a computerized dynamic posturography (CDP) system. Subjects were able to maintain upright stance with static head tilts, although postural sway was increased during neck extension. Postural stability was decreased during dynamic head tilts, and the degree of destabilization varied directly with increasing frequency of head tilt. In the absence of vision and accurate foot support surface inputs, postural stability may be compromised during dynamic head tilts due to a decreased ability of the vestibular system to discern the orientation of gravity.

  13. Behavioural evidence for a visual and proprioceptive control of head roll in hoverflies (Episyrphus balteatus).

    PubMed

    Goulard, Roman; Julien-Laferriere, Alice; Fleuriet, Jérome; Vercher, Jean-Louis; Viollet, Stéphane

    2015-12-01

    The ability of hoverflies to control their head orientation with respect to their body contributes importantly to their agility and their autonomous navigation abilities. Many tasks performed by this insect during flight, especially while hovering, involve a head stabilization reflex. This reflex, which is mediated by multisensory channels, prevents the visual processing from being disturbed by motion blur and maintains a consistent perception of the visual environment. The so-called dorsal light response (DLR) is another head control reflex, which makes insects sensitive to the brightest part of the visual field. In this study, we experimentally validate and quantify the control loop driving the head roll with respect to the horizon in hoverflies. The new approach developed here consisted of using an upside-down horizon in a body roll paradigm. In this unusual configuration, tethered flying hoverflies surprisingly no longer use purely vision-based control for head stabilization. These results shed new light on the role of neck proprioceptor organs in head and body stabilization with respect to the horizon. Based on the responses obtained with male and female hoverflies, an improved model was then developed in which the output signals delivered by the neck proprioceptor organs are combined with the visual error in the estimated position of the body roll. An internal estimation of the body roll angle with respect to the horizon might explain the extremely accurate flight performances achieved by some hovering insects. © 2015. Published by The Company of Biologists Ltd.

  14. Changes in Head Stability Control in Response to a Lateral Perturbation while Walking in Older Adults

    NASA Technical Reports Server (NTRS)

    Buccello, Regina R.; Cromwell, Ronita L.; Bloomberg, Jacob J.

    2008-01-01

    Falling is a main contributor of injury in older adults. The decline in sensory systems associated with aging limits information needed to successfully compensate for unexpected perturbations. Therefore, sensory changes result in older adults having problems maintaining balance stability when experiencing an unexpected lateral perturbation (e.g. slip) in the environment. The goal of this study was to determine head stability movement strategies used by older adults when experiencing an unexpected lateral perturbation during walking. A total of 16 healthy adults, aged 66-81 years, walked across a foam pathway 6 times. One piece of the foam pathway covered a movable platform that translated to the left when the subject stepped on the foam. Three trials were randomized in which the platform shifted. Angular rate sensors were placed on the center of mass for the head and trunk segments to collect head and trunk movement in all three planes of motion. The predominant movement strategies for maintaining head stability were determined from the results of the cross-correlation analyses between the head and trunk segments. The Chi square test of independence was used to evaluate the movement pattern distributions of head-trunk coordination during perturbed and non-perturbed walking. When perturbed, head stabilization was significantly challenged in the yaw and roll planes of motion. Subjects demonstrated a movement pattern of the head leading the trunk in an effort to stabilize the head. The older adult subjects used this head stabilization movement pattern to compensate for sensory changes when experiencing the unexpected lateral perturbation.

  15. A theoretical analysis of airplane longitudinal stability and control as affected by wind shear

    NASA Technical Reports Server (NTRS)

    Sherman, W. L.

    1977-01-01

    The longitudinal equations of motion with wind shear terms were used to analyze the stability and motions of a jet transport. A positive wind shear gives a decreasing head wind or changes a head wind into a tail wind. A negative wind shear gives a decreasing tail wind or changes a tail wind into a head wind. It was found that wind shear had very little effect on the short period mode and that negative wind shear, although it affected the phugoid, did not cause stability problems. On the other hand, it was found that positive wind shear can cause the phugoid to become aperiodic and unstable. In this case, a stability boundary for the phugoid was found that is valid for most aircraft at all flight speeds. Calculations of aircraft motions confirmed the results of the stability analysis. It was found that a flight path control automatic pilot and an airspeed control system provide good control in all types of wind shear. Appendixes give equations of motion that include the effects of downdrafts and updrafts and extend the longitudinal equations of motion for shear to six degrees of freedom.

  16. [Dynamic radioulnar convergence after Darrach operation, soft tissue stabilizing operations of the distal ulna and ulnar head prosthesis implantation--an experimental biomechanical study].

    PubMed

    Sauerbier, M; Hahn, M E; Fujita, M; Neale, P G; Germann, G; An, K N; Berger, R A

    2002-08-01

    The most common method of treating the arthrotic distal radioulnar joint (DRUJ) is resection of the entire ulnar head (Darrach procedure). Complications related to instability of the distal forearm resulting from loss of the ulnar head are usually manifested by pain and weak grip strength and have remained the drawbacks of this procedure. In an attempt to mechanically stabilize the distal forearm, an endoprosthesis was developed to replace the ulnar head after Darrach resection. The purpose of this study was to: 1) evaluate the dynamic effects of the Darrach procedure on radioulnar convergence; and 2) evaluate the mechanical efficacy of two soft tissue stabilizing techniques (Pronator quadratus advancement flap and ECU/FCU tenodesis) for the unstable distal ulnar stump and 3) the stability after the implantation of an ulnar head endoprosthesis following a Darrach resection on radioulnar convergence. With a dynamic PC-controled forearm simulator the rotation of 7 fresh-frozen cadaver upper extremities was actively and passively performed while loading relevant muscles. Resultant total forearm torque and the 3-dimensional kinematics of the ulna, radius and third metacarpal were recorded simultaneously. The implantation of the ulnar head endoprosthesis effectively restored the stability of the DRUJ. There were significantly better results after the implantation of the prosthesis compared with the Darrach and the soft tissue stabilization procedures. This study provides laboratory validity to the option of implanting an ulnar head endoprosthesis as an attempt to stabilize the distal forearm after Darrach resection in lieu of performing soft tissue stabilization techniques.

  17. Does scapula stabilizing t-shirt help over-head athletes in shoulder discomfort? A randomized control study.

    PubMed

    Pellegrini, Andrea; Pogliacomi, Francesco; Costantino, Cosimo; Desimoni, Stefano; Giovanelli, Margherita; Golz, Andrew; Tonino, Pietro; Ceccarelli, Francesco

    2016-04-15

    Scapular dyskinesis in pitchers can potentially lead to impairments in the optimal performance of muscles of the shoulder complex. The purpose of this prospective study was to evaluate whether the use of a scapula stabilizing t-shirt can decrease stress and discomfort in over-head baseball pitchers. Thirty-two semi-professional baseball pitchers were divided into 2 groups. Group A dressed the scapula stabilizing t-shirt during the weekly practice while group B (control group) continued to follow their training program without the t-shirt. All pitchers underwent a clinical examination at the beginning of the study (T0), 4 weeks (T1) and 8 weeks after (T2). Data collected showed a better clinical outcome at T1 which increased in T2 for pitchers in Group A, while in Group B athletes these positive results were not observed. This study underlines that scapula-stabilizing t-shirt can have positive effects on shoulder discomfort in over-head athletes.

  18. Walking stability and sensorimotor function in older people with diabetic peripheral neuropathy.

    PubMed

    Menz, Hylton B; Lord, Stephen R; St George, Rebecca; Fitzpatrick, Richard C

    2004-02-01

    To evaluate, in older people with diabetic peripheral neuropathy (DPN) and in age-matched controls, acceleration patterns of the head and pelvis when walking to determine the effect of lower-limb sensory loss on walking stability. Case-control study. Falls and balance laboratory in Australia. Thirty persons with diabetes mellitus (age range, 55-91 y) and 30 age-matched controls. Acceleration patterns of the head and pelvis were measured while participants walked on a level surface and an irregular walkway. Participants also underwent tests of vision, sensation, strength, reaction time, and balance. Temporospatial gait parameters and variables derived from acceleration signals. Participants with DPN had reduced walking speed, cadence, and step length, and less rhythmic acceleration patterns at the head and pelvis compared with controls. These differences were particularly evident when participants walked on the irregular surface. Participants with DPN also had impaired peripheral sensation, reaction time, and balance. Older people with DPN have an impaired ability to stabilize their body when walking on irregular surfaces, even if they adopt a more conservative gait pattern. These results provide further insights into the role of peripheral sensory input in the control of gait stability, and suggest possible mechanisms underlying the increased risk of falling in older people with diabetic neuropathy.

  19. Vestibular-somatosensory convergence in head movement control during locomotion after long-duration space flight.

    PubMed

    Mulavara, A P; Ruttley, T; Cohen, H S; Peters, B T; Miller, C; Brady, R; Merkle, L; Bloomberg, J J

    2012-01-01

    Space flight causes astronauts to be exposed to adaptation in both the vestibular and body load-sensing somatosensory systems. The goal of these studies was to examine the contributions of vestibular and body load-sensing somatosensory influences on vestibular mediated head movement control during locomotion after long-duration space flight. Subjects walked on a motor driven treadmill while performing a gaze stabilization task. Data were collected from three independent subject groups that included bilateral labyrinthine deficient (LD) patients, normal subjects before and after 30 minutes of 40% bodyweight unloaded treadmill walking, and astronauts before and after long-duration space flight. Motion data from the head and trunk segments were used to calculate the amplitude of angular head pitch and trunk vertical translation movement while subjects performed a gaze stabilization task, to estimate the contributions of vestibular reflexive mechanisms in head pitch movements. Exposure to unloaded locomotion caused a significant increase in head pitch movements in normal subjects, whereas the head pitch movements of LD patients were significantly decreased. This is the first evidence of adaptation of vestibular mediated head movement responses to unloaded treadmill walking. Astronaut subjects showed a heterogeneous response of both increases and decreases in the amplitude of head pitch movement. We infer that body load-sensing somatosensory input centrally modulates vestibular input and can adaptively modify vestibularly mediated head-movement control during locomotion. Thus, space flight may cause central adaptation of the converging vestibular and body load-sensing somatosensory systems leading to alterations in head movement control.

  20. Gaze stabilization in chronic vestibular-loss and in cerebellar ataxia: interactions of feedforward and sensory feedback mechanisms.

    PubMed

    Sağlam, M; Lehnen, N

    2014-01-01

    During gaze shifts, humans can use visual, vestibular, and proprioceptive feedback, as well as feedforward mechanisms, for stabilization against active and passive head movements. The contributions of feedforward and sensory feedback control, and the role of the cerebellum, are still under debate. To quantify these contributions, we increased the head moment of inertia in three groups (ten healthy, five chronic vestibular-loss and nine cerebellar-ataxia patients) while they performed large gaze shifts to flashed targets in darkness. This induces undesired head oscillations. Consequently, both active (desired) and passive (undesired) head movements had to be compensated for to stabilize gaze. All groups compensated for active and passive head movements, vestibular-loss patients less than the other groups (P < 0.001, passive/active compensatory gains: vestibular-loss 0.23 ± 0.09/0.43 ± 0.12, healthy 0.80 ± 0.17/0.83 ± 0.15, cerebellar-ataxia 0.68 ± 0.17/0.77 ± 0.30, mean ± SD). The compensation gain ratio against passive and active movements was smaller than one in vestibular-loss patients (0.54 ± 0.10, P=0.001). Healthy and cerebellar-ataxia patients did not differ in active and passive compensation. In summary, vestibular-loss patients can better stabilize gaze against active than against passive head movements. Therefore, feedforward mechanisms substantially contribute to gaze stabilization. Proprioception alone is not sufficient (gain 0.2). Stabilization against active and passive head movements was not impaired in our cerebellar ataxia patients.

  1. Neural control and precision of flight muscle activation in Drosophila.

    PubMed

    Lehmann, Fritz-Olaf; Bartussek, Jan

    2017-01-01

    Precision of motor commands is highly relevant in a large context of various locomotor behaviors, including stabilization of body posture, heading control and directed escape responses. While posture stability and heading control in walking and swimming animals benefit from high friction via ground reaction forces and elevated viscosity of water, respectively, flying animals have to cope with comparatively little aerodynamic friction on body and wings. Although low frictional damping in flight is the key to the extraordinary aerial performance and agility of flying birds, bats and insects, it challenges these animals with extraordinary demands on sensory integration and motor precision. Our review focuses on the dynamic precision with which Drosophila activates its flight muscular system during maneuvering flight, considering relevant studies on neural and muscular mechanisms of thoracic propulsion. In particular, we tackle the precision with which flies adjust power output of asynchronous power muscles and synchronous flight control muscles by monitoring muscle calcium and spike timing within the stroke cycle. A substantial proportion of the review is engaged in the significance of visual and proprioceptive feedback loops for wing motion control including sensory integration at the cellular level. We highlight that sensory feedback is the basis for precise heading control and body stability in flies.

  2. Unraveling the nature of hyperactivity in children with attention-deficit/hyperactivity disorder.

    PubMed

    Ohashi, Kyoko; Vitaliano, Gordana; Polcari, Ann; Teicher, Martin H

    2010-04-01

    Seated hyperactivity is a defining feature of the combined and predominantly hyperactive-impulsive subtypes of attention-deficit/hyperactivity disorder (ADHD), but its underlying nature is unknown. To determine whether hyperactivity is a consequence of an impaired ability to inhibit activity to low levels or to maintain positional stability. Case-control study. Academic research center and school. Sixty-two boys 9 to 12 years of age (of 73 screened), recruited from the community by advertisement, who met DSM-IV criteria for ADHD combined subtype on structured interview. Sixty-two controls were selected by matching for age and sex from a community sample of 1168 subjects in 3 participating school districts. Pupils with Conners' Teacher Rating Scores Revised within +/-1 SD of the mean for age were eligible for randomized matching. Intervention Infrared motion analysis of head-marker movements (50 Hz) during performance of a 15-minute cognitive control task. Subjects with ADHD were tested at least 18 hours following their last dose of methylphenidate and again 120 minutes after a 0.4-mg/kg probe dose. Inhibitory control (spike and basal amplitude) and head-marker stability (approximate entropy, Lyapunov, and spectral exponents). Inhibitory control measures were 2-fold higher in subjects with ADHD (d' = 0.63-0.95). Group differences in head-marker stability were even greater (d' = 2.20-4.71; receiver operating characteristic area = 0.956-1.0). Methylphenidate restored inhibitory ability to control levels but only partially corrected stability deficits, which still distinguished subjects with ADHD from controls (receiver operating characteristic area = 0.722-0.995). Children with ADHD have a deficient ability to inhibit activity to low levels and unstable control of head-marker position characterized by deterministic chaos (sensitivity to initial conditions). These deficits differed in degree of correctability by methylphenidate, suggesting that they may be mediated by different neural circuits (eg, corticostriatal vs cerebrovestibular).

  3. Stabilization and mobility of the head and trunk in wild monkeys during terrestrial and flat-surface walks and gallops.

    PubMed

    Dunbar, Donald C; Badam, Gyani L; Hallgrímsson, Benedikt; Vieilledent, Stéphane

    2004-02-01

    This study investigated the patterns of rotational mobility (> or =20 degrees ) and stability (< or =20 degrees ) of the head and trunk in wild Indian monkeys during natural locomotion on the ground and on the flat-topped surfaces of walls. Adult hanuman langurs (Semnopithecus entellus) and bonnet macaques (Macaca radiata) of either gender were cine filmed in lateral view. Whole-body horizontal linear displacement, head and trunk pitch displacement relative to space (earth horizontal), and vertical head displacement were measured from the cine films. Head-to-trunk pitch angle was calculated from the head-to-space and trunk-to-space measurements. Locomotor velocities, cycle durations, angular segmental velocities, mean segmental positions and mean peak frequencies of vertical and angular head displacements were then calculated from the displacement data. Yaw rotations were observed qualitatively. During quadrupedal walks by both species, the head was free to rotate in the pitch and yaw planes on a stabilized trunk. By contrast, during quadrupedal gallops by both species, the trunk pitched on a stabilized head. During both gaits in both species, head and trunk pitch rotations were symmetrical about comparable mean positions in both gaits, with mean head position aligning the horizontal semicircular canals near earth horizontal. Head pitch direction countered head vertical displacement direction to varying degrees during walks and only intermittently during gallops, providing evidence that correctional head pitch rotations are not essential for gaze stabilization. Head-to-space pitch velocities were below 350 deg. s(-1), the threshold above which, at least among humans, the vestibulo-ocular reflex (VOR) becomes saturated. Mean peak frequencies of vertical translations and pitch rotations of the head ranged from 1 Hz to 2 Hz, a lower frequency range than that in which inertia is predicted to be the major stabilizer of the head in these species. Some variables, which were common to both walks and gallops in both species, are likely to reflect constraints in sensorimotor control. Other variables, which differed between the two gaits in both species, are likely to reflect kinematic differences, whereas variables that differed between the two species are attributed primarily to morphological and behavioural differences. It is concluded that either the head or the trunk can provide the nervous system with a reference frame for spatial orientation and that the segment providing that reference can change, depending upon the kinematic characteristics of the chosen gait.

  4. Voluntary presetting of the vestibular ocular reflex permits gaze stabilization despite perturbation of fast head movements

    NASA Technical Reports Server (NTRS)

    Zangemeister, Wolfgang H.

    1989-01-01

    Normal subjects are able to change voluntarily and continuously their head-eye latency together with their compensatory eye movement gain. A continuous spectrum of intent-latency modes of the subject's coordinated gaze through verbal feedback could be demonstrated. It was also demonstrated that the intent to counteract any perturbation of head-eye movement, i.e., the mental set, permitted the subjects to manipulate consciously their vestibular ocular reflex (VOR) gain. From the data, it is inferred that the VOR is always on. It may be, however, variably suppressed by higher cortical control. With appropriate training, head-mounted displays should permit an easy VOR presetting that leads to image stabilization, perhaps together with a decrease of possible misjudgements.

  5. Gender differences in head-neck segment dynamic stabilization during head acceleration.

    PubMed

    Tierney, Ryan T; Sitler, Michael R; Swanik, C Buz; Swanik, Kathleen A; Higgins, Michael; Torg, Joseph

    2005-02-01

    Recent epidemiological research has revealed that gender differences exist in concussion incidence but no study has investigated why females may be at greater risk of concussion. Our purpose was to determine whether gender differences existed in head-neck segment kinematic and neuromuscular control variables responses to an external force application with and without neck muscle preactivation. Forty (20 females and 20 males) physically active volunteers participated in the study. The independent variables were gender, force application (known vs unknown), and force direction (forced flexion vs forced extension). The dependent variables were kinematic and EMG variables, head-neck segment stiffness, and head-neck segment flexor and extensor isometric strength. Statistical analyses consisted of multiple multivariate and univariate analyses of variance, follow-up univariate analyses of variance, and t-tests (P < or = 0.05). Gender differences existed in head-neck segment dynamic stabilization during head angular acceleration. Females exhibited significantly greater head-neck segment peak angular acceleration (50%) and displacement (39%) than males despite initiating muscle activity significantly earlier (SCM only) and using a greater percentage of their maximum head-neck segment muscle activity (79% peak activity and 117% muscle activity area). The head-neck segment angular acceleration differences may be because females exhibited significantly less isometric strength (49%), neck girth (30%), and head mass (43%), resulting in lower levels of head-neck segment stiffness (29%). For our subject demographic, the results revealed gender differences in head-neck segment dynamic stabilization during head acceleration in response to an external force application. Females exhibited significantly greater head-neck segment peak angular acceleration and displacement than males despite initiating muscle activity earlier (SCM only) and using a greater percentage of their maximum head-neck segment muscle activity.

  6. Imposed Faster and Slower Walking Speeds Influence Gait Stability Differently in Parkinson Fallers.

    PubMed

    Cole, Michael H; Sweeney, Matthew; Conway, Zachary J; Blackmore, Tim; Silburn, Peter A

    2017-04-01

    To evaluate the effect of imposed faster and slower walking speeds on postural stability in people with Parkinson disease (PD). Cross-sectional cohort study. General community. Patients with PD (n=84; 51 with a falls history; 33 without) and age-matched controls (n=82) were invited to participate via neurology clinics and preexisting databases. Of those contacted, 99 did not respond (PD=36; controls=63) and 27 were not interested (PD=18; controls=9). After screening, a further 10 patients were excluded; 5 had deep brain stimulation surgery and 5 could not accommodate to the treadmill. The remaining patients (N=30) completed all assessments and were subdivided into PD fallers (n=10), PD nonfallers (n=10), and age-matched controls (n=10) based on falls history. Not applicable. Three-dimensional accelerometers assessed head and trunk accelerations and allowed calculation of harmonic ratios and root mean square (RMS) accelerations to assess segment control and movement amplitude. Symptom severity, balance confidence, and medical history were established before participants walked on a treadmill at 70%, 100%, and 130% of their preferred speed. Head and trunk control was lower for PD fallers than PD nonfallers and older adults. Significant interactions indicated head and trunk control increased with speed for PD nonfallers and older adults, but did not improve at faster speeds for PD fallers. Vertical head and trunk accelerations increased with walking speed for PD nonfallers and older adults, while the PD fallers demonstrated greater anteroposterior RMS accelerations compared with both other groups. The results suggest that improved gait dynamics do not necessarily represent improved walking stability, and this must be respected when rehabilitating gait in patients with PD. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Integrated Locomotor Function Tests for Countermeasure Evaluation

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Landsness, E. C.; Black, F. O.

    2005-01-01

    Following spaceflight crewmembers experience locomotor dysfunction due to inflight adaptive alterations in sensorimotor function. Countermeasures designed to mitigate these postflight gait alterations need to be assessed with a new generation of tests that evaluate the interaction of various sensorimotor sub-systems central to locomotor control. The goal of the present study was to develop new functional tests of locomotor control that could be used to test the efficacy of countermeasures. These tests were designed to simultaneously examine the function of multiple sensorimotor systems underlying the control of locomotion and be operationally relevant to the astronaut population. Traditionally, gaze stabilization has been studied almost exclusively in seated subjects performing target acquisition tasks requiring only the involvement of coordinated eye-head movements. However, activities like walking involve full-body movement and require coordination between lower limbs and the eye-head-trunk complex to achieve stabilized gaze during locomotion. Therefore the first goal of this study was to determine how the multiple, interdependent, full-body sensorimotor gaze stabilization subsystems are functionally coordinated during locomotion. In an earlier study we investigated how alteration in gaze tasking changes full-body locomotor control strategies. Subjects walked on a treadmill and either focused on a central point target or read numeral characters. We measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. In comparison to the point target fixation condition, the results of the number reading task showed that compensatory head pitch movements increased, peak head acceleration was reduced and knee flexion at heel-strike was increased. In a more recent study we investigated the adaptive remodeling of the full-body gaze control systems following exposure to visual-vestibular conflict. Subjects walked on a treadmill before and after a 30- minute exposure to 0.5X minifying during which self-generated sinusoidal vertical head rotations were performed while seated. Following exposure to visual-vestibular conflict subjects showed a restriction in compensatory head movements, increased knee and ankle flexion after heel-strike and a decrease in the rate of body loading during the rapid weight transfer phase after the heel strike event. Taken together, results from both studies provide evidence that the full body contributes to gaze stabilization during locomotion, and that different functional elements are responsive to changes in visual task constraints and are subject to adaptive alterations following exposure to visual-vestibular conflict. This information provides the basis for the design of a new generation of integrative tests that incorporate the evaluation of multiple neural control systems relevant to astronaut operational performance.

  8. Influence of vision on head stabilization strategies in older adults during walking.

    PubMed

    Cromwell, Ronita L; Newton, Roberta A; Forrest, Gail

    2002-07-01

    Maintaining balance during dynamic activities is essential for preventing falls in older adults. Head stabilization contributes to dynamic balance, especially during the functional task of walking. Head stability and the role of vision in this process have not been studied during walking in older adults. Seventeen older adults (76.2 +/- 6.9 years) and 20 young adults (26.0 +/- 3.4 years) walked with their eyes open (EO), with their eyes closed (EC), and with fixed gaze (FG). Participants performed three trials of each condition. Sagittal plane head and trunk angular velocities in space were obtained using an infrared camera system with passive reflective markers. Frequency analyses of head-on-trunk with respect to trunk gains and phases were examined for head-trunk movement strategies used for head stability. Average walking velocity, cadence, and peak head velocity were calculated for each condition. Differences between age groups demonstrated that older adults decreased walking velocity in EO (p =.022). FG (p = .021), and EC (p = .022). and decreased cadence during EC (p = .007). Peak head velocity also decreased across conditions (p < .0001) for older adults. Movement patterns demonstrated increased head stability during EO. diminished head stability with EC, and improved head stability with FG as older adult patterns resembled those of young adults. Increased stability of the lower extremity outcome measures for older adults was indicated by reductions in walking velocity and cadence. Concomitant increases in head stability were related to visual tasks. Increased stability may serve as a protective mechanism to prevent falls. Further, vision facilitates the head stabilization process for older adults to compensate for age-related decrements in other sensory systems subserving dynamic balance.

  9. Characterization of the Head Stabilization Response to a Lateral Perturbation During Walking in Older Adults

    NASA Technical Reports Server (NTRS)

    Buccello-Stout, Regina R.; Cromwell, Ronita L.; Bloomberg, Jacob J.

    2009-01-01

    A main contributor of fractures in older adults is from a lateral fall. The decline in sensory systems results in difficulty maintaining balance stability. Head stabilization contributes to postural control by serving as a stable platform for the sensory systems. The purpose of this study was to characterize the head stabilization response to a lateral perturbation while walking. A total of 16 healthy older adults, aged 66-81 years, walked across a foam pathway 6 times. One piece of the foam pathway covered a movable platform that translated to the left when the subject stepped on the foam. Three trials were randomized in which the platform shifted. Angular rate sensors placed on the center of mass of the head and trunk collected head and trunk movement in all three planes of motion. The roll plane was analyzed to examine motion in the plane of the perturbation. Subjects stepped onto the platform with the right foot. Recovery step time and distance were recorded. The first trial was analyzed to capture the novelty of the perturbation. Results indicate a significant difference in footfall distance t=0.004, p<0.05, as well as the speed of foot recovery t=0.001, p<0.05, between natural and perturbed walking. Results indicate that the head t=0.005, p<0.05, and trunk t=0.0001, p<0.05, velocities increase during perturbed compared to natural walking. Older adults place their recovery foot down faster when perturbed to re-establish their base of support. Head and trunk segments are less stable and move with greater velocities to reestablish stability when perturbed.

  10. Eye-head coordination during free exploration in human and cat.

    PubMed

    Einhäuser, Wolfgang; Moeller, Gudrun U; Schumann, Frank; Conradt, Jörg; Vockeroth, Johannes; Bartl, Klaus; Schneider, Erich; König, Peter

    2009-05-01

    Eye, head, and body movements jointly control the direction of gaze and the stability of retinal images in most mammalian species. The contribution of the individual movement components, however, will largely depend on the ecological niche the animal occupies and the layout of the animal's retina, in particular its photoreceptor density distribution. Here the relative contribution of eye-in-head and head-in-world movements in cats is measured, and the results are compared to recent human data. For the cat, a lightweight custom-made head-mounted video setup was used (CatCam). Human data were acquired with the novel EyeSeeCam device, which measures eye position to control a gaze-contingent camera in real time. For both species, analysis was based on simultaneous recordings of eye and head movements during free exploration of a natural environment. Despite the substantial differences in ecological niche, photoreceptor density, and saccade frequency, eye-movement characteristics in both species are remarkably similar. Coordinated eye and head movements dominate the dynamics of the retinal input. Interestingly, compensatory (gaze-stabilizing) movements play a more dominant role in humans than they do in cats. This finding was interpreted to be a consequence of substantially different timescales for head movements, with cats' head movements showing about a 5-fold faster dynamics than humans. For both species, models and laboratory experiments therefore need to account for this rich input dynamic to obtain validity for ecologically realistic settings.

  11. Identifying Head-Trunk and Lower Limb Contributions to Gaze Stabilization During Locomotion

    NASA Technical Reports Server (NTRS)

    Mulavara, Ajitkumar P.; Bloomberg, Jacob J.

    2003-01-01

    The goal of the present study was to determine how the multiple, interdependent full-body sensorimotor subsystems respond to a change in gaze stabilization task constraints during locomotion. Nine subjects performed two gaze stabilization tasks while walking at 6.4 km/hr on a motorized treadmill: 1) focusing on a central point target; 2) reading numeral characters; both presented at 2m in front at the level of their eyes. While subjects performed the tasks we measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. We tested the hypothesis that with the increased demands placed on visual acuity during the number recognition task, subjects would modify full-body segmental kinematics in order to reduce perturbations to the head in order to successfully perform the task. We found that while reading numeral characters as - compared to the central point target: 1) compensatory head pitch movement was on average 22% greater despite the fact that the trunk pitch and trunk vertical translation movement control were not significantly changed; 2) coordination patterns between head and trunk as reflected by the peak cross correlation between the head pitch and trunk pitch motion as well as the peak cross correlation between the head pitch and vertical trunk translation motion were not significantly changed; 3) knee joint total movement was on average 11% greater during the period from the heel strike event to the peak knee flexion event in stance phase of the gait cycle; 4) peak acceleration measured at the head was significantly reduced by an average of 13% in four of the six subjects. This was so even when the peak acceleration at the shank and the transmissibility of the shock wave at heel strike (measured by the peak acceleration ratio of the head/shank) remained unchanged. Taken together these results provide further evidence that the full body contributes to gaze stabilization during locomotion, and that its different functional elements can be modified online to contribute to gaze stabilization for different visual task constraints.

  12. A structural equation model relating impaired sensorimotor function, fear of falling and gait patterns in older people.

    PubMed

    Menz, Hylton B; Lord, Stephen R; Fitzpatrick, Richard C

    2007-02-01

    Many falls in older people occur while walking, however the mechanisms responsible for gait instability are poorly understood. Therefore, the aim of this study was to develop a plausible model describing the relationships between impaired sensorimotor function, fear of falling and gait patterns in older people. Temporo-spatial gait parameters and acceleration patterns of the head and pelvis were obtained from 100 community-dwelling older people aged between 75 and 93 years while walking on an irregular walkway. A theoretical model was developed to explain the relationships between these variables, assuming that head stability is a primary output of the postural control system when walking. This model was then tested using structural equation modeling, a statistical technique which enables the testing of a set of regression equations simultaneously. The structural equation model indicated that: (i) reduced step length has a significant direct and indirect association with reduced head stability; (ii) impaired sensorimotor function is significantly associated with reduced head stability, but this effect is largely indirect, mediated by reduced step length, and; (iii) fear of falling is significantly associated with reduced step length, but has little direct influence on head stability. These findings provide useful insights into the possible mechanisms underlying gait characteristics and risk of falling in older people. Particularly important is the indication that fear-related step length shortening may be maladaptive.

  13. Postural Instability Induced by Visual Motion Stimuli in Patients With Vestibular Migraine

    PubMed Central

    Lim, Yong-Hyun; Kim, Ji-Soo; Lee, Ho-Won; Kim, Sung-Hee

    2018-01-01

    Patients with vestibular migraine are susceptible to motion sickness. This study aimed to determine whether the severity of posture instability is related to the susceptibility to motion sickness. We used a visual motion paradigm with two conditions of the stimulated retinal field and the head posture to quantify postural stability while maintaining a static stance in 18 patients with vestibular migraine and in 13 age-matched healthy subjects. Three parameters of postural stability showed differences between VM patients and controls: RMS velocity (0.34 ± 0.02 cm/s vs. 0.28 ± 0.02 cm/s), RMS acceleration (8.94 ± 0.74 cm/s2 vs. 6.69 ± 0.87 cm/s2), and sway area (1.77 ± 0.22 cm2 vs. 1.04 ± 0.25 cm2). Patients with vestibular migraine showed marked postural instability of the head and neck when visual stimuli were presented in the retinal periphery. The pseudo-Coriolis effect induced by head roll tilt was not responsible for the main differences in postural instability between patients and controls. Patients with vestibular migraine showed a higher visual dependency and low stability of the postural control system when maintaining quiet standing, which may be related to susceptibility to motion sickness. PMID:29930534

  14. Postural Instability Induced by Visual Motion Stimuli in Patients With Vestibular Migraine.

    PubMed

    Lim, Yong-Hyun; Kim, Ji-Soo; Lee, Ho-Won; Kim, Sung-Hee

    2018-01-01

    Patients with vestibular migraine are susceptible to motion sickness. This study aimed to determine whether the severity of posture instability is related to the susceptibility to motion sickness. We used a visual motion paradigm with two conditions of the stimulated retinal field and the head posture to quantify postural stability while maintaining a static stance in 18 patients with vestibular migraine and in 13 age-matched healthy subjects. Three parameters of postural stability showed differences between VM patients and controls: RMS velocity (0.34 ± 0.02 cm/s vs. 0.28 ± 0.02 cm/s), RMS acceleration (8.94 ± 0.74 cm/s 2 vs. 6.69 ± 0.87 cm/s 2 ), and sway area (1.77 ± 0.22 cm 2 vs. 1.04 ± 0.25 cm 2 ). Patients with vestibular migraine showed marked postural instability of the head and neck when visual stimuli were presented in the retinal periphery. The pseudo-Coriolis effect induced by head roll tilt was not responsible for the main differences in postural instability between patients and controls. Patients with vestibular migraine showed a higher visual dependency and low stability of the postural control system when maintaining quiet standing, which may be related to susceptibility to motion sickness.

  15. Stability analysis of automobile driver steering control

    NASA Technical Reports Server (NTRS)

    Allen, R. W.

    1981-01-01

    In steering an automobile, the driver must basically control the direction of the car's trajectory (heading angle) and the lateral deviation of the car relative to a delineated pathway. A previously published linear control model of driver steering behavior which is analyzed from a stability point of view is considered. A simple approximate expression for a stability parameter, phase margin, is derived in terms of various driver and vehicle control parameters, and boundaries for stability are discussed. A field test study is reviewed that includes the measurement of driver steering control parameters. Phase margins derived for a range of vehicle characteristics are found to be generally consistent with known adaptive properties of the human operator. The implications of these results are discussed in terms of driver adaptive behavior.

  16. Ivermectin lipid-based nanocarriers as novel formulations against head lice.

    PubMed

    Ullio-Gamboa, Gabriela; Palma, Santiago; Benoit, Jean Pierre; Allemandi, Daniel; Picollo, María Inés; Toloza, Ariel Ceferino

    2017-08-01

    The use of pyrethroids to control the human head louse, Pediculus humanus capitis De Geer (Anoplura: Pediculidae), has suffered considerable loss of efficacy due to the evolution of resistance. Thus, the development of efficiently insecticide delivery systems is imperative for the control of head lice. We studied the insecticidal activity of ivermectin-loaded lipid nanocapsules (IVM-LNC) against permethrin-resistant head lice from Argentina. The LNC, prepared by a phase inversion procedure, were characterized in terms of size, surface potential, and physical stability. These nanoparticles were nearly spherical with mean diameters of 55 nm and narrow size distribution (PI ≤ 0.2). The KT 50 mortality values of head lice after exposure to two IVM-LNC formulations (0.11 and 0.28%) were significantly smaller (5 and 3 h, respectively) compared to those exposed only to LNC control group (8 h). This investigation showed the effectiveness in the encapsulation of ivermectin (IVM) into stable LNC dispersion with a potential clinical activity against head lice.

  17. Dynamic and kinematic strategies for head movement control

    NASA Technical Reports Server (NTRS)

    Peterson, B. W.; Choi, H.; Hain, T.; Keshner, E.; Peng, G. C.

    2001-01-01

    This paper describes our analysis of the complex head-neck system using a combination of experimental and modeling approaches. Dynamical analysis of head movements and EMG activation elicited by perturbation of trunk position has examined functional contributions of biomechanically and neurally generated forces in lumped systems with greatly simplified kinematics. This has revealed that visual and voluntary control of neck muscles and the dynamic and static vestibulocollic and cervicocollic reflexes preferentially govern head-neck system state in different frequency domains. It also documents redundant control, which allows the system to compensate for lesions and creates a potential for substantial variability within and between subjects. Kinematic studies have indicated the existence of reciprocal and co-contraction strategies for voluntary force generation, of a vestibulocollic strategy for stabilizing the head during body perturbations and of at least two strategies for voluntary head tracking. Each strategy appears to be executed by a specific muscle synergy that is presumably optimized to efficiently meet the demands of the task.

  18. Full-Body Gaze Control Mechanisms Elicited During Locomotion: Effects Of VOR Adaptation

    NASA Technical Reports Server (NTRS)

    Mulavara, A. P.; Houser, J.; Peters, B.; Miller, C.; Richards, J.; Marshburn, A.; Brady, R.; Cohen, H.; Bloomberg, J. J.

    2004-01-01

    Control of locomotion requires precise interaction between several sensorimotor subsystems. During locomotion the performer must satisfy two performance criteria: maintain stable forward translation and to stabilize gaze (McDonald, et al., 1997). Precise coordination demands integration of multiple sensorimotor subsystems for fulfilling both criteria. In order to test the general hypothesis that the whole body can serve as an integrated gaze stabilization system, we have previously investigated how the multiple, interdependent full-body sensorimotor subsystems respond to changes in gaze stabilization task constraints during locomotion (Mulavara and Bloomberg, 2003). The results suggest that the full body contributes to gaze stabilization during locomotion, and that its different functional elements respond to changes in visual task constraints. The goal of this study was to determine how the multiple, interdependent, full-body sensorimotor subsystems aiding gaze stabilization during locomotion are functionally coordinated after the vestibulo-ocular reflex (VOR) gain has been altered. We investigated the potential of adaptive remodeling of the full-body gaze control system following exposure to visual-vestibular conflict known to adaptively reduce the VOR. Subjects (n=14) walked (6.4 km/h) on the treadmill before and after they were exposed to 0.5X manifying lenses worn for 30 minutes during self-generated sinusoidal vertical head rotations performed while seated. In this study we measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. Results indicate that, following exposure to the 0.5X minifying lenses, there was a significant increase in the duration of stance and stride times, alteration in the amplitude of head movement with respect to space and a significant increase in the amount of knee flexion during the initial stance phase of the gait cycle. This study provides further evidence that the full body contributes to gaze stabilization during locomotion, and that different functional elements are responsive to changes in visual task constraints and are subject to adaptive alteration following exposure to visual-vestibular conflict.

  19. Identifying head-trunk and lower limb contributions to gaze stabilization during locomotion

    NASA Technical Reports Server (NTRS)

    Mulavara, Ajitkumar P.; Bloomberg, Jacob J.

    2002-01-01

    The goal of the present study was to determine how the multiple, interdependent full-body sensorimotor subsystems respond to a change in gaze stabilization task constraints during locomotion. Nine subjects performed two gaze stabilization tasks while walking at 6.4 km/hr on a motorized treadmill: 1) focusing on a central point target; 2) reading numeral characters; both presented at 2 m in front at the level of their eyes. While subjects performed the tasks we measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, tibia and foot, accelerations along the vertical axis at the head and the tibia, and the vertical forces acting on the support surface. We tested the hypothesis that with the increased demands placed on visual acuity during the number recognition task, subjects would modify full-body segmental kinematics in order to reduce perturbations to the head in order to successfully perform the task. We found that while reading numeral characters as compared to the central point target: 1) compensatory head pitch movement was on average 22% greater despite the fact that the trunk pitch and trunk vertical translation movement control were not significantly changed; 2) coordination patterns between head and trunk as reflected by the peak cross correlation between the head pitch and trunk pitch motion as well as the peak cross correlation between the head pitch and vertical trunk translation motion were not significantly changed; 3) knee joint total movement was on average 11% greater during the period from the heel strike event to the peak knee flexion event in stance phase of the gait cycle; 4) peak acceleration measured at the head was significantly reduced by an average of 13% in four of the six subjects. This was so even when the peak acceleration at the tibia and the transmission of the shock wave at heel strike (measured by the peak acceleration ratio of the head/tibia and the time lag between the tibial and head peak accelerations) remained unchanged. Taken together these results provide further evidence that the full body contributes to gaze stabilization during locomotion, and that its different functional elements can be modified online to contribute to gaze stabilization for different visual task constraints.

  20. Vestibulospinal control of reflex and voluntary head movement

    NASA Technical Reports Server (NTRS)

    Boyle, R.; Peterson, B. W. (Principal Investigator)

    2001-01-01

    Secondary canal-related vestibulospinal neurons respond to an externally applied movement of the head in the form of a firing rate modulation that encodes the angular velocity of the movement, and reflects in large part the input "head velocity in space" signal carried by the semicircular canal afferents. In addition to the head velocity signal, the vestibulospinal neurons can carry a more processed signal that includes eye position or eye velocity, or both (see Boyle on ref. list). To understand the control signals used by the central vestibular pathways in the generation of reflex head stabilization, such as the vestibulocollic reflex (VCR), and the maintenance of head posture, it is essential to record directly from identified vestibulospinal neurons projecting to the cervical spinal segments in the alert animal. The present report discusses two key features of the primate vestibulospinal system. First, the termination morphology of vestibulospinal axons in the cervical segments of the spinal cord is described to lay the structural basis of vestibulospinal control of head/neck posture and movement. And second, the head movement signal content carried by the same class of secondary vestibulospinal neurons during the actual execution of the VCR and during self-generated, or active, rapid head movements is presented.

  1. Influence of the hydrophilic head size and hydrophobic tail length of surfactants on the ability of micelles to stabilize citral.

    PubMed

    Hong, Chi Rac; Park, Sung Joon; Choi, Seung Jun

    2016-07-01

    Surfactant-made micelles can control the rate of chemical degradation of poorly water-soluble food flavors. To evaluate how the molecular structure of surfactant has an influence on the chemical decomposition rate of citral, micelles were prepared with polyoxyethylene alkyl ether-type surfactants that had similar molecular structures but various hydrophilic head sizes and hydrophobic tail lengths. At a critical 20× micelle concentration of surfactant, there was no significant difference in the chemical degradation rate of citral in micelles in neutral pH, regardless of the hydrophilic head size or hydrophobic tail length. In an acidic environment, the degradation rate constant of citral generally increased proportionally with increasing hydrophilic head size of surfactant (0.1563 and 0.2217 for surfactants with 23 and 100 oxyethylene units, respectively) but the length of hydrophobic tail did not affect the citral stability. Also, little difference (0.2217 and 0.2265 for surfactant having 100 oxyethylene units with and without Fe(3+) ) in degradation rate constant of citral between simple micellar solution and micellar solution containing iron suggested that iron ions could not accelerate citral degradation in micelles, regardless of the form of iron (Fe(2+) and Fe(3+) ). This work concludes that although the concentration of surfactant could be relevant, if its concentration could be controlled in the same manner as the critical micelle concentration, then a polyethylene alkyl ether-type surfactant with a small hydrophilic head could more efficiently stabilize citral at an acidic pH. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  2. Postural control and head stability during natural gaze behaviour in 6- to 12-year-old children.

    PubMed

    Schärli, A M; van de Langenberg, R; Murer, K; Müller, R M

    2013-06-01

    We investigated how the influence of natural exploratory gaze behaviour on postural control develops from childhood into adulthood. In a cross-sectional design, we compared four age groups: 6-, 9-, 12-year-olds and young adults. Two experimental trials were performed: quiet stance with a fixed gaze (fixed) and quiet stance with natural exploratory gaze behaviour (exploratory). The latter was elicited by having participants watch an animated short film on a large screen in front of them. 3D head rotations in space and centre of pressure (COP) excursions on the ground plane were measured. Across conditions, both head rotation and COP displacement decreased with increasing age. Head movement was greater in the exploratory condition in all age groups. In all children-but not in adults-COP displacement was markedly greater in the exploratory condition. Bivariate correlations across groups showed highly significant positive correlations between COP displacement in ML direction and head rotation in yaw, roll, and pitch in both conditions. The regularity of COP displacements did not show a clear developmental trend, which indicates that COP dynamics were qualitatively similar across age groups. Together, the results suggest that the contribution of head movement to eye-head saccades decreases with age and that head instability-in part resulting from such gaze-related head movements-is an important limiting factor in children's postural control. The lack of head stabilisation might particularly affect children in everyday activities in which both postural control and visual exploration are required.

  3. Auditory cues for orientation and postural control in sighted and congenitally blind people

    NASA Technical Reports Server (NTRS)

    Easton, R. D.; Greene, A. J.; DiZio, P.; Lackner, J. R.

    1998-01-01

    This study assessed whether stationary auditory information could affect body and head sway (as does visual and haptic information) in sighted and congenitally blind people. Two speakers, one placed adjacent to each ear, significantly stabilized center-of-foot-pressure sway in a tandem Romberg stance, while neither a single speaker in front of subjects nor a head-mounted sonar device reduced center-of-pressure sway. Center-of-pressure sway was reduced to the same level in the two-speaker condition for sighted and blind subjects. Both groups also evidenced reduced head sway in the two-speaker condition, although blind subjects' head sway was significantly larger than that of sighted subjects. The advantage of the two-speaker condition was probably attributable to the nature of distance compared with directional auditory information. The results rule out a deficit model of spatial hearing in blind people and are consistent with one version of a compensation model. Analysis of maximum cross-correlations between center-of-pressure and head sway, and associated time lags suggest that blind and sighted people may use different sensorimotor strategies to achieve stability.

  4. Haptic cues for orientation and postural control in sighted and blind individuals

    NASA Technical Reports Server (NTRS)

    Jeka, J. J.; Easton, R. D.; Bentzen, B. L.; Lackner, J. R.

    1996-01-01

    Haptic cues from fingertip contact with a stable surface attenuate body sway in subjects even when the contact forces are too small to provide physical support of the body. We investigated how haptic cues derived from contact of a cane with a stationary surface at low force levels aids postural control in sighted and congenitally blind individuals. Five sighted (eyes closed) and five congenitally blind subjects maintained a tandem Romberg stance in five conditions: (1) no cane; (2,3) touch contact (< 2 N of applied force) while holding the cane in a vertical or slanted orientation; and (4,5) force contact (as much force as desired) in the vertical and slanted orientations. Touch contact of a cane at force levels below those necessary to provide significant physical stabilization was as effective as force contact in reducing postural sway in all subjects, compared to the no-cane condition. A slanted cane was far more effective in reducing postural sway than was a perpendicular cane. Cane use also decreased head displacement of sighted subjects far more than that of blind subjects. These results suggest that head movement control is linked to postural control through gaze stabilization reflexes in sighted subjects; such reflexes are absent in congenitally blind individuals and may account for their higher levels of head displacement.

  5. Aviation spatial orientation in relationship to head position and attitude interpretation.

    PubMed

    Patterson, F R; Cacioppo, A J; Gallimore, J J; Hinman, G E; Nalepka, J P

    1997-06-01

    Conventional wisdom describing aviation spatial awareness assumes that pilots view a moving horizon through the windscreen. This assumption presupposes head alignment with the cockpit "Z" axis during both visual (VMC) and instrument (IMC) maneuvers. Even though this visual paradigm is widely accepted, its accuracy has not been verified. The purpose of this research was to determine if a visually induced neck reflex causes pilots to align their heads toward the horizon, rather than the cockpit vertical axis. Based on literature describing reflexive head orientation in terrestrial environments it was hypothesized that during simulated VMC aircraft maneuvers, pilots would align their heads toward the horizon. Some 14 military pilots completed two simulated flights in a stationary dome simulator. The flight profile consisted of five separate tasks, four of which evaluated head tilt during exposure to unique visual conditions and one examined occurrences of disorientation during unusual attitude recovery. During simulated visual flight maneuvers, pilots tilted their heads toward the horizon (p < 0.0001). Under IMC, pilots maintained head alignment with the vertical axis of the aircraft. During VMC maneuvers pilots reflexively tilt their heads toward the horizon, away from the Gz axis of the cockpit. Presumably, this behavior stabilizes the retinal image of the horizon (1 degree visual-spatial cue), against which peripheral images of the cockpit (2 degrees visual-spatial cue) appear to move. Spatial disorientation, airsickness, and control reversal error may be related to shifts in visual-vestibular sensory alignment during visual transitions between VMC (head tilt) and IMC (Gz head stabilized) conditions.

  6. The role of passive avian head stabilization in flapping flight

    PubMed Central

    Pete, Ashley E.; Kress, Daniel; Dimitrov, Marina A.; Lentink, David

    2015-01-01

    Birds improve vision by stabilizing head position relative to their surroundings, while their body is forced up and down during flapping flight. Stabilization is facilitated by compensatory motion of the sophisticated avian head–neck system. While relative head motion has been studied in stationary and walking birds, little is known about how birds accomplish head stabilization during flapping flight. To unravel this, we approximate the avian neck with a linear mass–spring–damper system for vertical displacements, analogous to proven head stabilization models for walking humans. We corroborate the model's dimensionless natural frequency and damping ratios from high-speed video recordings of whooper swans (Cygnus cygnus) flying over a lake. The data show that flap-induced body oscillations can be passively attenuated through the neck. We find that the passive model robustly attenuates large body oscillations, even in response to head mass and gust perturbations. Our proof of principle shows that bird-inspired drones with flapping wings could record better images with a swan-inspired passive camera suspension. PMID:26311316

  7. A Reward-Based Behavioral Platform to Measure Neural Activity during Head-Fixed Behavior.

    PubMed

    Micallef, Andrew H; Takahashi, Naoya; Larkum, Matthew E; Palmer, Lucy M

    2017-01-01

    Understanding the neural computations that contribute to behavior requires recording from neurons while an animal is behaving. This is not an easy task as most subcellular recording techniques require absolute head stability. The Go/No-Go sensory task is a powerful decision-driven task that enables an animal to report a binary decision during head-fixation. Here we discuss how to set up an Ardunio and Python based platform system to control a Go/No-Go sensory behavior paradigm. Using an Arduino micro-controller and Python-based custom written program, a reward can be delivered to the animal depending on the decision reported. We discuss the various components required to build the behavioral apparatus that can control and report such a sensory stimulus paradigm. This system enables the end user to control the behavioral testing in real-time and therefore it provides a strong custom-made platform for probing the neural basis of behavior.

  8. Changes in Trunk and Head Stability in Children with Cerebral Palsy after Hippotherapy: A Pilot Study

    ERIC Educational Resources Information Center

    Shurtleff, Tim L.; Engsberg, Jack R.

    2010-01-01

    Hippotherapy (HPOT) is a therapy that uses horse movement. This pilot investigation objectively evaluated the efficacy of HPOT in improving head/trunk stability in children with cerebral palsy (CP). The participants were six children with spastic diplegia and six children without disability. Head and trunk stability was challenged by using a…

  9. Cervical sensorimotor control in idiopathic cervical dystonia: A cross-sectional study.

    PubMed

    De Pauw, Joke; Mercelis, Rudy; Hallemans, Ann; Michiels, Sarah; Truijen, Steven; Cras, Patrick; De Hertogh, Willem

    2017-09-01

    Patients with idiopathic adult-onset cervical dystonia (CD) experience an abnormal head posture and involuntary muscle contractions. Although the exact areas affected in the central nervous system remain uncertain, impaired functions in systems stabilizing the head and neck are apparent such as the somatosensory and sensorimotor integration systems. The aim of the study is to investigate cervical sensorimotor control dysfunction in patients with CD. Cervical sensorimotor control was assessed by a head repositioning task in 24 patients with CD and 70 asymptomatic controls. Blindfolded participants were asked to reposition their head to a previously memorized neutral head position (NHP) following an active movement (flexion, extension, left, and right rotation). The repositioning error (joint position error, JPE) was registered via 3D motion analysis with an eight-camera infrared system (VICON ® T10). Disease-specific characteristics of all patients were obtained via the Tsui scale, Cervical Dystonia Impact Profile (CDIP-58), and Toronto Western Spasmodic Rating Scale. Patients with CD showed larger JPE than controls (mean difference of 1.5°, p  <   .006), and systematically 'overshoot', i.e. surpassed the NHP, whereas control subjects 'undershoot', i.e. fall behind the NHP. The JPE did not correlate with disease-specific characteristics. Cervical sensorimotor control is impaired in patients with CD. As cervical sensorimotor control can be trained, this might be a potential treatment option for therapy, adjuvant to botulinum toxin injections.

  10. Functional Coordination of a Full-Body Gaze Control Mechanisms Elicited During Locomotion

    NASA Technical Reports Server (NTRS)

    Bloomberg, Jacob J.; Mulavara, Ajitkumar P.; Cohen, Helen S.

    2003-01-01

    Control of locomotion requires precise interaction between several sensorimotor subsystems. Exposure to the microgravity environment of spaceflight leads to postflight adaptive alterations in these multiple subsystems leading to postural and gait disturbances. Countermeasures designed to mitigate these postflight gait alterations will need to be assessed with a new generation of functional tests that evaluate the interaction of various elements central to locomotor control. The goal of this study is to determine how the multiple, interdependent, full- body sensorimotor subsystems aiding gaze stabilization during locomotion are functionally coordinated. To explore this question two experiments were performed. In the first study (Study 1) we investigated how alteration in gaze tasking changes full-body locomotor control strategies. Subjects (n=9) performed two discreet gaze stabilization tasks while walking at 6.4 km/hr on a motorized treadmill: 1) focusing on a central point target; 2) reading numeral characters; both presented at 2m in front at eye level. The second study (Study 2) investigated the potential of adaptive remodeling of the full-body gaze control systems following exposure to visual-vestibular conflict. Subjects (n=14) walked (6.4 km/h) on the treadmill before and after they were exposed to 0.5X minifying lenses worn for 30 minutes during self-generated sinusoidal vertical head rotations performed while seated. In both studies we measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. Results from Study 1 showed that while reading numeral characters as compared to the central point target: 1) compensatory head pitch movements were on average 22% greater 2) the peak acceleration measured at the head was significantly reduced by an average of 13% in four of the six subjects 3) the knee joint total movement was on average 11% greater during the period from the heel strike event to the peak knee flexion event in stance phase of the gait cycle. Results from Study 2 indicate that following exposure to visual-vestibular conflict changes in full-body strategies were observed consistent with the requirement to aid gaze stabilization during locomotion.

  11. pH-Cleavable Nucleoside Lipids: A New Paradigm for Controlling the Stability of Lipid-Based Delivery Systems.

    PubMed

    Oumzil, Khalid; Benizri, Sébastien; Tonelli, Giovanni; Staedel, Cathy; Appavoo, Ananda; Chaffanet, Max; Navailles, Laurence; Barthélémy, Philippe

    2015-11-01

    Lipid-based delivery systems are an established technology with considerable clinical acceptance and several applications in human. Herein, we report the design, synthesis and evaluation of novel orthoester nucleoside lipids (ONLs) for the modulation of liposome stability. The ONLs contain head groups with 3'-orthoester nucleoside derivatives featuring positive or negative charges. The insertion of the orthoester function in the NL structures allows the formation of pH-sensitive liposomes. ONL-based liposomes can be hydrolyzed to provide nontoxic products, including nucleoside derivatives and hexadecanol. To allow the release to be tunable at different hydrolysis rates, the charge of the polar head structure is modulated, and the head group can be released at a biologically relevant pH. Crucially, when ONLs are mixed with natural phosphocholine lipids (PC), the resultant liposome evolves toward the formation of a hexadecanol/PC lamellar system. Biological evaluation shows that stable nucleic acid lipid particles (SNALPs) formulated with ONLs and siRNAs can effectively enter into tumor cells and release their nucleic acid payload in response to an intracellular acidic environment. This results in a much higher antitumor activity than conventional SNALPs. The ability to use pH-cleavable nucleolipids to control the stability of lipid-based delivery systems represents a promising approach for the intracellular delivery of drug cargos. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Effectuation of adaptive stability and postural alignment strategies are decreased by alcohol intoxication.

    PubMed

    Hafström, A; Modig, F; Magnusson, M; Fransson, P A

    2014-06-01

    Human stability control is a complex process comprising contributions from several partly independent mechanisms such as coordination, feedback and feed-forward control, and adaptation. Acute alcohol intoxication impairs these functions and is recognized as a major contributor to fall traumas. The study aimed to investigate how alcohol intoxication at .06% and .10% blood alcohol concentration (BAC) affected the movement spans and control of posture alignment. The angular positions of the head, shoulder, hip and knees relative to the ankles were measured with a 3D motion analysis system in 25 healthy adults during standing with eyes open or closed and with or without vibratory balance perturbations. Alcohol intoxication significantly increased the movement spans of the head, shoulders, hip and knees in anteroposterior and lateral directions during quiet stance (p < or = .047 and p < or = .003) and balance perturbations (p<.001, both directions). Alcohol intoxication also decreased the ability to reduce the movement spans through adaptation in both anteroposterior (p < or = .011) and lateral (p < or = .004) directions. When sober and submitted to balance perturbations, the subjects aligned the head, shoulders, hip and knees more forward relative to the ankle joint (p < .001), hence adopting a more resilient posture increasing the safety margin for backward falls. Alcohol intoxication significantly delayed this forward realignment (p < or = .022). Alcohol intoxication did not cause any significant posture realignment in the lateral direction. Thus, initiation of adaptive posture realignments to alcohol or other disruptions might be context dependent and associated with reaching a certain level of stability threats. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Effects of Control-Response Characteristics on the Capability of Helicopter for Use as a Gun Platform

    NASA Technical Reports Server (NTRS)

    Pegg, Robert J.; Connor, Andrew B.

    1960-01-01

    An investigation with a variable-stability helicopter was undertaken to ascertain the steadiness and ability to "hold on" to the target of a helicopter employed as a gun platform. Simulated tasks were per formed under differing flight conditions with the control-response characteristics of the helicopter varied for each task. The simulated gun-platform mission included: Variations of headings with respect to wind, constant altitude and "swing around" to a wind heading of 0 deg, and increases in altitude while performing a swing around to a wind heading of 0 deg. The results showed that increases in control power and damping increased pilot ability to hold on to the target with fewer yawing oscillations and in a shorter time. The results also indicated that wind direction must be considered in accuracy assessment. Greatest accuracy throughout these tests was achieved by aiming upwind.

  14. Ultra-high temperature stability Joule-Thomson cooler with capability to accomodate pressure variations

    NASA Technical Reports Server (NTRS)

    Bard, Steven (Inventor); Wu, Jiunn-Jeng (Inventor); Trimble, Curtis A. (Inventor)

    1992-01-01

    A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.

  15. Ultra-high temperature stability Joule-Thomson cooler with capability to accomodate pressure variations

    NASA Astrophysics Data System (ADS)

    Bard, Steven; Wu, Jiunn-Jeng; Trimble, Curtis A.

    1992-06-01

    A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.

  16. ASB clinical biomechanics award winner 2016: Assessment of gaze stability within 24-48hours post-concussion.

    PubMed

    Murray, Nicholas G; D'Amico, Nathan R; Powell, Douglas; Mormile, Megan E; Grimes, Katelyn E; Munkasy, Barry A; Gore, Russell K; Reed-Jones, Rebecca J

    2017-05-01

    Approximately 90% of athletes with concussion experience a certain degree of visual system dysfunction immediately post-concussion. Of these abnormalities, gaze stability deficits are denoted as among the most common. Little research quantitatively explores these variables post-concussion. As such, the purpose of this study was to investigate and compare gaze stability between a control group of healthy non-injured athletes and a group of athletes with concussions 24-48hours post-injury. Ten collegiate NCAA Division I athletes with concussions and ten healthy control collegiate athletes completed two trials of a sport-like antisaccade postural control task, the Wii Fit Soccer Heading Game. During play all participants were instructed to minimize gaze deviations away from a central fixed area. Athletes with concussions were assessed within 24-48 post-concussion while healthy control data were collected during pre-season athletic screening. Raw ocular point of gaze coordinates were tracked with a monocular eye tracking device (240Hz) and motion capture during the postural task to determine the instantaneous gaze coordinates. This data was exported and analyzed using a custom algorithm. Independent t-tests analyzed gaze resultant distance, prosaccade errors, mean vertical velocity, and mean horizontal velocity. Athletes with concussions had significantly greater gaze resultant distance (p=0.006), prosaccade errors (p<0.001), and horizontal velocity (p=0.029) when compared to healthy controls. These data suggest that athletes with concussions had less control of gaze during play of the Wii Fit Soccer Heading Game. This could indicate a gaze stability deficit via potentially reduced cortical inhibition that is present within 24-48hours post-concussion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Gaze stability, dynamic balance and participation deficits in people with multiple sclerosis at fall-risk.

    PubMed

    Garg, Hina; Dibble, Leland E; Schubert, Michael C; Sibthorp, Jim; Foreman, K Bo; Gappmaier, Eduard

    2018-05-05

    Despite the common complaints of dizziness and demyelination of afferent or efferent pathways to and from the vestibular nuclei which may adversely affect the angular Vestibulo-Ocular Reflex (aVOR) and vestibulo-spinal function in persons with Multiple Sclerosis (PwMS), few studies have examined gaze and dynamic balance function in PwMS. 1) Determine the differences in gaze stability, dynamic balance and participation measures between PwMS and controls, 2) Examine the relationships between gaze stability, dynamic balance and participation. Nineteen ambulatory PwMS at fall-risk and 14 age-matched controls were recruited. Outcomes included (a) gaze stability [angular Vestibulo-Ocular Reflex (aVOR) gain (ratio of eye to head velocity); number of Compensatory Saccades (CS) per head rotation; CS latency; gaze position error; Coefficient of Variation (CV) of aVOR gain], (b) dynamic balance [Functional Gait Assessment, FGA; four square step test], and (c) participation [dizziness handicap inventory; activities-specific balance confidence scale]. Separate independent t-tests and Pearson's correlations were calculated. PwMS were age = 53 ± 11.7yrs and had 4.2 ± 3.3 falls/yr. PwMS demonstrated significant (p<0.05) impairments in gaze stability, dynamic balance and participation measures compared to controls. CV of aVOR gain and CS latency were significantly correlated with FGA. Deficits and correlations across a spectrum of disability measures highlight the relevance of gaze and dynamic balance assessment in PwMS. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  18. A Reward-Based Behavioral Platform to Measure Neural Activity during Head-Fixed Behavior

    PubMed Central

    Micallef, Andrew H.; Takahashi, Naoya; Larkum, Matthew E.; Palmer, Lucy M.

    2017-01-01

    Understanding the neural computations that contribute to behavior requires recording from neurons while an animal is behaving. This is not an easy task as most subcellular recording techniques require absolute head stability. The Go/No-Go sensory task is a powerful decision-driven task that enables an animal to report a binary decision during head-fixation. Here we discuss how to set up an Ardunio and Python based platform system to control a Go/No-Go sensory behavior paradigm. Using an Arduino micro-controller and Python-based custom written program, a reward can be delivered to the animal depending on the decision reported. We discuss the various components required to build the behavioral apparatus that can control and report such a sensory stimulus paradigm. This system enables the end user to control the behavioral testing in real-time and therefore it provides a strong custom-made platform for probing the neural basis of behavior. PMID:28620282

  19. Metropolitan Spokane Region Water Resources Study. Appendix G. Planning Criteria

    DTIC Science & Technology

    1976-01-01

    head or more of dairy cattle c. 2500 swine over 55 pounds d. 10,000 head of sheep e. 55,000 turkeys f. 100,000 laying hens or broilers g. 30,000 laying...hens or broilers with liquid manure handling systems h. 5000 ducks i. combinations of animals per schedule 317-20 IM 2. Fish production facilities. a...previously stabilized by the equivalent of anaerobic digestion . 2. Lhere public access is not positively controlled, pathogen re- duction beyond that

  20. Direct observation of the myosin Va recovery stroke that contributes to unidirectional stepping along actin.

    PubMed

    Shiroguchi, Katsuyuki; Chin, Harvey F; Hannemann, Diane E; Muneyuki, Eiro; De La Cruz, Enrique M; Kinosita, Kazuhiko

    2011-04-01

    Myosins are ATP-driven linear molecular motors that work as cellular force generators, transporters, and force sensors. These functions are driven by large-scale nucleotide-dependent conformational changes, termed "strokes"; the "power stroke" is the force-generating swinging of the myosin light chain-binding "neck" domain relative to the motor domain "head" while bound to actin; the "recovery stroke" is the necessary initial motion that primes, or "cocks," myosin while detached from actin. Myosin Va is a processive dimer that steps unidirectionally along actin following a "hand over hand" mechanism in which the trailing head detaches and steps forward ∼72 nm. Despite large rotational Brownian motion of the detached head about a free joint adjoining the two necks, unidirectional stepping is achieved, in part by the power stroke of the attached head that moves the joint forward. However, the power stroke alone cannot fully account for preferential forward site binding since the orientation and angle stability of the detached head, which is determined by the properties of the recovery stroke, dictate actin binding site accessibility. Here, we directly observe the recovery stroke dynamics and fluctuations of myosin Va using a novel, transient caged ATP-controlling system that maintains constant ATP levels through stepwise UV-pulse sequences of varying intensity. We immobilized the neck of monomeric myosin Va on a surface and observed real time motions of bead(s) attached site-specifically to the head. ATP induces a transient swing of the neck to the post-recovery stroke conformation, where it remains for ∼40 s, until ATP hydrolysis products are released. Angle distributions indicate that the post-recovery stroke conformation is stabilized by ≥ 5 k(B)T of energy. The high kinetic and energetic stability of the post-recovery stroke conformation favors preferential binding of the detached head to a forward site 72 nm away. Thus, the recovery stroke contributes to unidirectional stepping of myosin Va.

  1. A review of some head-up display formats. [tests on sensing equipment for flights following partly visible terrain close to the ground

    NASA Technical Reports Server (NTRS)

    Naish, J. M.

    1979-01-01

    Two alternate head-up display devices (HUD) were compared for properties relevant to the accurate performance of concurrent tasks in real flight conditions and in various flight modes. The comparisons were made to find the disorientation resistance of the HUDs along with the tracking accuracy, interference resistance, fixation resistance, and error resistance. The use of displacement and flight path information for vertical control is discussed in terms of flight stability. Several combinations of symbols and driving signals are described, including a compensated control law, which were used in simulated flight to deal with wind shear.

  2. Extremum seeking with bounded update rates

    DOE PAGES

    Scheinker, Alexander; Krstić, Miroslav

    2013-11-16

    In this work, we present a form of extremum seeking (ES) in which the unknown function being minimized enters the system’s dynamics as the argument of a cosine or sine term, thereby guaranteeing known bounds on update rates and control efforts. We present general n-dimensional optimization and stabilization results as well as 2D vehicle control, with bounded velocity and control efforts. For application to autonomous vehicles, tracking a source in a GPS denied environment with unknown orientation, this ES approach allows for smooth heading angle actuation, with constant velocity, and in application to a unicycle-type vehicle results in control abilitymore » as if the vehicle is fully actuated. Our stability analysis is made possible by the classic results of Kurzweil, Jarnik, Sussmann, and Liu, regarding systems with highly oscillatory terms. In our stability analysis, we combine the averaging results with a semi-global practical stability result under small parametric perturbations developed by Moreau and Aeyels.« less

  3. Comparison of Femoral Head Rotation and Varus Collapse Between a Single Lag Screw and Integrated Dual Screw Intertrochanteric Hip Fracture Fixation Device Using a Cadaveric Hemi-Pelvis Biomechanical Model.

    PubMed

    Santoni, Brandon G; Nayak, Aniruddh N; Cooper, Seth A; Smithson, Ian R; Cox, Jacob L; Marberry, Scott T; Sanders, Roy W

    2016-04-01

    This study compared the stabilizing effect of 2 intertrochanteric (IT) fracture fixation devices in a cadaveric hemi-pelvis biomechanical model. Eleven pairs of cadaveric osteopenic female hemi-pelves with intact hip joint and capsular ligaments were used. An unstable IT fracture (OTA 31-A2) was created in each specimen and stabilized with a single lag screw device (Gamma 3) or an integrated dual screw (IDS) device (InterTAN). The hemi-pelves were inverted, coupled to a biaxial apparatus and subjected to 13.5 k cycles of loading (3 months) using controlled, oscillating pelvic rotation (0-90 degrees) plus cyclic axial femoral loading at a 2:1 body weight (BW) ratio. Femoral head rotation and varus collapse were monitored optoelectonically. For specimens surviving 3 months of loading, additional loading was performed in 0.25 × BW/250 cycle increments to a maximum of 4 × BW or failure. Femoral head rotation with IDS fixation was significantly less than the single lag screw construct after 3 months of simulated loading (P = 0.016). Maximum femoral head rotation at the end of 4 × BW loading was 7× less for the IDS construct (P = 0.006). Varus collapse was significantly less with the IDS construct over the entire loading cycle (P = 0.021). In this worst-case model of an osteopenic, unstable, IT fracture, the IDS construct, likely owing to its larger surface area, noncylindrical profile, and fracture compression, provided significantly greater stability and resistance to femoral head rotation and varus collapse.

  4. Landslide kinematics and their potential controls from hourly to decadal timescales: Insights from integrating ground-based InSAR measurements with structural maps and long-term monitoring data

    USGS Publications Warehouse

    Schulz, William; Coe, Jeffrey A.; Ricci, P.P; Smoczyk, Gregory M.; Shurtleff, Brett L; Panosky, J

    2017-01-01

    Knowledge of kinematics is rudimentary for understanding landslide controls and is increasingly valuable with greater spatiotemporal coverage. However, characterizing landslide-wide kinematics is rare, especially at broadly ranging timescales. We used highly detailed kinematic data obtained using photogrammetry and field mapping during the 1980s and 1990s and our 4.3-day ground-based InSAR survey during 2010 to study kinematics of the large, persistently moving Slumgullion landslide. The landslide was segregated into 11 kinematic elements using the 1980s–1990s data and the InSAR survey revealed most of these elements within a few hours. Averages of InSAR-derived displacement point measures within each element agreed well with higher quality in situ observations; averaging was deemed necessary because adverse look angles for the radar coupled with tree cover on the landslide introduced error in the InSAR results. We found that the landslide moved during 2010 at about half its 1985–1990 speed, but slowing was most pronounced at the landslide head. Gradually decreased precipitation and increased temperature between the periods likely resulted in lower groundwater levels and consequent slowing of the landslide. We used GPS survey results and limit-equilibrium modeling to analyze changing stability of the landslide head from observed thinning and found that its stability increased between the two periods, which would result in its slowing, and the consequent slowing of the entire landslide. Additionally, InSAR results suggested movement of kinematic element boundaries in the head region and our field mapping verified that they moved and changed character, likely because of the long-term increasing head stability. On an hourly basis, InSAR results were near error bounds but suggested landslide acceleration in response to seemingly negligible rainfall. Pore-pressure diffusion modeling suggested that rainfall infiltration affected frictional strength only to shallow depths along the landslide's marginal faults, highlighting their importance in controlling landslide stability. Hourly results also suggested that motion propagated along the 3.9-km length of the active landslide, even following sub-millimeter displacements, while strengthening of landslide shear boundaries during faster movement was likely critical in regulating the landslide's motion. Hence, detailed kinematic characterizations obtained from traditional and emerging approaches helped to reveal that mechanisms controlling landslide movement and evolution over decades also are critical to sub-millimeter movement on a nearly continuous basis.

  5. Landslide kinematics and their potential controls from hourly to decadal timescales: Insights from integrating ground-based InSAR measurements with structural maps and long-term monitoring data

    NASA Astrophysics Data System (ADS)

    Schulz, William H.; Coe, Jeffrey A.; Ricci, Pier P.; Smoczyk, Gregory M.; Shurtleff, Brett L.; Panosky, Joanna

    2017-05-01

    Knowledge of kinematics is rudimentary for understanding landslide controls and is increasingly valuable with greater spatiotemporal coverage. However, characterizing landslide-wide kinematics is rare, especially at broadly ranging timescales. We used highly detailed kinematic data obtained using photogrammetry and field mapping during the 1980s and 1990s and our 4.3-day ground-based InSAR survey during 2010 to study kinematics of the large, persistently moving Slumgullion landslide. The landslide was segregated into 11 kinematic elements using the 1980s-1990s data and the InSAR survey revealed most of these elements within a few hours. Averages of InSAR-derived displacement point measures within each element agreed well with higher quality in situ observations; averaging was deemed necessary because adverse look angles for the radar coupled with tree cover on the landslide introduced error in the InSAR results. We found that the landslide moved during 2010 at about half its 1985-1990 speed, but slowing was most pronounced at the landslide head. Gradually decreased precipitation and increased temperature between the periods likely resulted in lower groundwater levels and consequent slowing of the landslide. We used GPS survey results and limit-equilibrium modeling to analyze changing stability of the landslide head from observed thinning and found that its stability increased between the two periods, which would result in its slowing, and the consequent slowing of the entire landslide. Additionally, InSAR results suggested movement of kinematic element boundaries in the head region and our field mapping verified that they moved and changed character, likely because of the long-term increasing head stability. On an hourly basis, InSAR results were near error bounds but suggested landslide acceleration in response to seemingly negligible rainfall. Pore-pressure diffusion modeling suggested that rainfall infiltration affected frictional strength only to shallow depths along the landslide's marginal faults, highlighting their importance in controlling landslide stability. Hourly results also suggested that motion propagated along the 3.9-km length of the active landslide, even following sub-millimeter displacements, while strengthening of landslide shear boundaries during faster movement was likely critical in regulating the landslide's motion. Hence, detailed kinematic characterizations obtained from traditional and emerging approaches helped to reveal that mechanisms controlling landslide movement and evolution over decades also are critical to sub-millimeter movement on a nearly continuous basis.

  6. Head Stability and Head-Trunk Coordination in Horseback Riders: The Contribution of Visual Information According to Expertise

    PubMed Central

    Olivier, Agnès; Faugloire, Elise; Lejeune, Laure; Biau, Sophie; Isableu, Brice

    2017-01-01

    Maintaining equilibrium while riding a horse is a challenging task that involves complex sensorimotor processes. We evaluated the relative contribution of visual information (static or dynamic) to horseback riders' postural stability (measured from the variability of segment position in space) and the coordination modes they adopted to regulate balance according to their level of expertise. Riders' perceptual typologies and their possible relation to postural stability were also assessed. Our main assumption was that the contribution of visual information to postural control would be reduced among expert riders in favor of vestibular and somesthetic reliance. Twelve Professional riders and 13 Club riders rode an equestrian simulator at a gallop under four visual conditions: (1) with the projection of a simulated scene reproducing what a rider sees in the real context of a ride in an outdoor arena, (2) under stroboscopic illumination, preventing access to dynamic visual cues, (3) in normal lighting but without the projected scene (i.e., without the visual consequences of displacement) and (4) with no visual cues. The variability of the position of the head, upper trunk and lower trunk was measured along the anteroposterior (AP), mediolateral (ML), and vertical (V) axes. We computed discrete relative phase to assess the coordination between pairs of segments in the anteroposterior axis. Visual field dependence-independence was evaluated using the Rod and Frame Test (RFT). The results showed that the Professional riders exhibited greater overall postural stability than the Club riders, revealed mainly in the AP axis. In particular, head variability was lower in the Professional riders than in the Club riders in visually altered conditions, suggesting a greater ability to use vestibular and somesthetic information according to task constraints with expertise. In accordance with this result, RFT perceptual scores revealed that the Professional riders were less dependent on the visual field than were the Club riders. Finally, the Professional riders exhibited specific coordination modes that, unlike the Club riders, departed from pure in-phase and anti-phase patterns and depended on visual conditions. The present findings provide evidence of major differences in the sensorimotor processes contributing to postural control with expertise in horseback riding. PMID:28194100

  7. Research on the magnetorheological finishing (MRF) technology with dual polishing heads

    NASA Astrophysics Data System (ADS)

    Huang, Wen; Zhang, Yunfei; He, Jianguo; Zheng, Yongcheng; Luo, Qing; Hou, Jing; Yuan, Zhigang

    2014-08-01

    Magnetorheological finishing (MRF) is a key polishing technique capable of rapidly converging to the required surface figure. Due to the deficiency of general one-polishing-head MRF technology, a dual polishing heads MRF technology was studied and a dual polishing heads MRF machine with 8 axes was developed. The machine has the ability to manufacture large aperture optics with high figure accuracy. The large polishing head is suitable for polishing large aperture optics, controlling large spatial length's wave structures, correcting low-medium frequency errors with high removal rates. While the small polishing head has more advantages in manufacturing small aperture optics, controlling small spatial wavelength's wave structures, correcting mid-high frequency and removing nanoscale materials. Material removal characteristic and figure correction ability for each of large and small polishing head was studied. Each of two polishing heads respectively acquired stable and valid polishing removal function and ultra-precision flat sample. After a single polishing iteration using small polishing head, the figure error in 45mm diameter of a 50 mm diameter plano optics was significantly improved from 0.21λ to 0.08λ by PV (RMS 0.053λ to 0.015λ). After three polishing iterations using large polishing head , the figure error in 410mm×410mm of a 430mm×430mm large plano optics was significantly improved from 0.40λ to 0.10λ by PV (RMS 0.068λ to 0.013λ) .This results show that the dual polishing heads MRF machine not only have good material removal stability, but also excellent figure correction capability.

  8. Stabilization and mobility of the head, neck and trunk in horses during overground locomotion: comparisons with humans and other primates.

    PubMed

    Dunbar, Donald C; Macpherson, Jane M; Simmons, Roger W; Zarcades, Athina

    2008-12-01

    Segmental kinematics were investigated in horses during overground locomotion and compared with published reports on humans and other primates to determine the impact of a large neck on rotational mobility (> 20 deg.) and stability (< or = 20 deg.) of the head and trunk. Three adult horses (Equus caballus) performing walks, trots and canters were videotaped in lateral view. Data analysis included locomotor velocity, segmental positions, pitch and linear displacements and velocities, and head displacement frequencies. Equine, human and monkey skulls and cervical spines were measured to estimate eye and vestibular arc length during head pitch displacements. Horses stabilized all three segments in all planes during all three gaits, unlike monkeys and humans who make large head pitch and yaw rotations during walks, and monkeys that make large trunk pitch rotations during gallops. Equine head angular displacements and velocities, with some exceptions during walks, were smaller than in humans and other primates. Nevertheless, owing to greater off-axis distances, orbital and vestibular arc lengths remained larger in horses, with the exception of head-neck axial pitch during trots, in which equine arc lengths were smaller than in running humans. Unlike monkeys and humans, equine head peak-frequency ranges fell within the estimated range in which inertia has a compensatory stabilizing effect. This inertial effect was typically over-ridden, however, by muscular or ligamentous intervention. Thus, equine head pitch was not consistently compensatory, as reported in humans. The equine neck isolated the head from the trunk enabling both segments to provide a spatial reference frame.

  9. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    NASA Astrophysics Data System (ADS)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  10. JackIn Head: Immersive Visual Telepresence System with Omnidirectional Wearable Camera.

    PubMed

    Kasahara, Shunichi; Nagai, Shohei; Rekimoto, Jun

    2017-03-01

    Sharing one's own immersive experience over the Internet is one of the ultimate goals of telepresence technology. In this paper, we present JackIn Head, a visual telepresence system featuring an omnidirectional wearable camera with image motion stabilization. Spherical omnidirectional video footage taken around the head of a local user is stabilized and then broadcast to others, allowing remote users to explore the immersive visual environment independently of the local user's head direction. We describe the system design of JackIn Head and report the evaluation results of real-time image stabilization and alleviation of cybersickness. Then, through an exploratory observation study, we investigate how individuals can remotely interact, communicate with, and assist each other with our system. We report our observation and analysis of inter-personal communication, demonstrating the effectiveness of our system in augmenting remote collaboration.

  11. How Lovebirds Maneuver Rapidly Using Super-Fast Head Saccades and Image Feature Stabilization

    PubMed Central

    Kress, Daniel; van Bokhorst, Evelien; Lentink, David

    2015-01-01

    Diurnal flying animals such as birds depend primarily on vision to coordinate their flight path during goal-directed flight tasks. To extract the spatial structure of the surrounding environment, birds are thought to use retinal image motion (optical flow) that is primarily induced by motion of their head. It is unclear what gaze behaviors birds perform to support visuomotor control during rapid maneuvering flight in which they continuously switch between flight modes. To analyze this, we measured the gaze behavior of rapidly turning lovebirds in a goal-directed task: take-off and fly away from a perch, turn on a dime, and fly back and land on the same perch. High-speed flight recordings revealed that rapidly turning lovebirds perform a remarkable stereotypical gaze behavior with peak saccadic head turns up to 2700 degrees per second, as fast as insects, enabled by fast neck muscles. In between saccades, gaze orientation is held constant. By comparing saccade and wingbeat phase, we find that these super-fast saccades are coordinated with the downstroke when the lateral visual field is occluded by the wings. Lovebirds thus maximize visual perception by overlying behaviors that impair vision, which helps coordinate maneuvers. Before the turn, lovebirds keep a high contrast edge in their visual midline. Similarly, before landing, the lovebirds stabilize the center of the perch in their visual midline. The perch on which the birds land swings, like a branch in the wind, and we find that retinal size of the perch is the most parsimonious visual cue to initiate landing. Our observations show that rapidly maneuvering birds use precisely timed stereotypic gaze behaviors consisting of rapid head turns and frontal feature stabilization, which facilitates optical flow based flight control. Similar gaze behaviors have been reported for visually navigating humans. This finding can inspire more effective vision-based autopilots for drones. PMID:26107413

  12. The IBM HeadTracking Pointer: improvements in vision-based pointer control.

    PubMed

    Kjeldsen, Rick

    2008-07-01

    Vision-based head trackers have been around for some years and are even beginning to be commercialized, but problems remain with respect to usability. Users without the ability to use traditional pointing devices--the intended audience of such systems--have no alternative if the automatic bootstrapping process fails. There is room for improvement in face tracking, and the pointer movement dynamics do not support accurate and efficient pointing. This paper describes the IBM HeadTracking Pointer, a system which attempts to directly address some of these issues. Head gestures are used to provide the end user a greater level of autonomous control over the system. A novel face-tracking algorithm reduces drift under variable lighting conditions, allowing the use of absolute, rather than relative, pointer positioning. Most importantly, the pointer dynamics have been designed to take into account the constraints of head-based pointing, with a non-linear gain which allows stability in fine pointer movement, high speed on long transitions and adjustability to support users with different movement dynamics. User studies have identified some difficulties with training the system and some characteristics of the pointer motion that take time to get used to, but also good user feedback and very promising performance results.

  13. Stabilization and mobility of the head, neck and trunk in horses during overground locomotion: comparisons with humans and other primates

    PubMed Central

    Dunbar, Donald C.; Macpherson, Jane M.; Simmons, Roger W.; Zarcades, Athina

    2009-01-01

    SUMMARY Segmental kinematics were investigated in horses during overground locomotion and compared with published reports on humans and other primates to determine the impact of a large neck on rotational mobility (>20deg.) and stability (≤20deg.) of the head and trunk. Three adult horses (Equus caballus) performing walks, trots and canters were videotaped in lateral view. Data analysis included locomotor velocity, segmental positions, pitch and linear displacements and velocities, and head displacement frequencies. Equine, human and monkey skulls and cervical spines were measured to estimate eye and vestibular arc length during head pitch displacements. Horses stabilized all three segments in all planes during all three gaits, unlike monkeys and humans who make large head pitch and yaw rotations during walks, and monkeys that make large trunk pitch rotations during gallops. Equine head angular displacements and velocities, with some exceptions during walks, were smaller than in humans and other primates. Nevertheless, owing to greater off-axis distances, orbital and vestibular arc lengths remained larger in horses, with the exception of head–neck axial pitch during trots, in which equine arc lengths were smaller than in running humans. Unlike monkeys and humans, equine head peak-frequency ranges fell within the estimated range in which inertia has a compensatory stabilizing effect. This inertial effect was typically over-ridden, however, by muscular or ligamentous intervention. Thus, equine head pitch was not consistently compensatory, as reported in humans. The equine neck isolated the head from the trunk enabling both segments to provide a spatial reference frame. PMID:19043061

  14. State-dependent sensorimotor processing: gaze and posture stability during simulated flight in birds.

    PubMed

    McArthur, Kimberly L; Dickman, J David

    2011-04-01

    Vestibular responses play an important role in maintaining gaze and posture stability during rotational motion. Previous studies suggest that these responses are state dependent, their expression varying with the environmental and locomotor conditions of the animal. In this study, we simulated an ethologically relevant state in the laboratory to study state-dependent vestibular responses in birds. We used frontal airflow to simulate gliding flight and measured pigeons' eye, head, and tail responses to rotational motion in darkness, under both head-fixed and head-free conditions. We show that both eye and head response gains are significantly higher during flight, thus enhancing gaze and head-in-space stability. We also characterize state-specific tail responses to pitch and roll rotation that would help to maintain body-in-space orientation during flight. These results demonstrate that vestibular sensorimotor processing is not fixed but depends instead on the animal's behavioral state.

  15. State-dependent sensorimotor processing: gaze and posture stability during simulated flight in birds

    PubMed Central

    McArthur, Kimberly L.

    2011-01-01

    Vestibular responses play an important role in maintaining gaze and posture stability during rotational motion. Previous studies suggest that these responses are state dependent, their expression varying with the environmental and locomotor conditions of the animal. In this study, we simulated an ethologically relevant state in the laboratory to study state-dependent vestibular responses in birds. We used frontal airflow to simulate gliding flight and measured pigeons′ eye, head, and tail responses to rotational motion in darkness, under both head-fixed and head-free conditions. We show that both eye and head response gains are significantly higher during flight, thus enhancing gaze and head-in-space stability. We also characterize state-specific tail responses to pitch and roll rotation that would help to maintain body-in-space orientation during flight. These results demonstrate that vestibular sensorimotor processing is not fixed but depends instead on the animal's behavioral state. PMID:21307332

  16. Deliberately Light Interpersonal Contact Affects the Control of Head Stability During Walking in Children and Adolescents With Cerebral Palsy.

    PubMed

    Schulleri, Katrin Hanna; Burfeind, Frauke; Höß-Zenker, Beate; Feketené Szabó, Éva; Herzig, Nadine; Ledebt, Annick; Johannsen, Leif

    2017-09-01

    To evaluate the potential of deliberately light interpersonal touch (IPT) for reducing excessive head and trunk sway during self-paced walking in children and adolescents with cerebral palsy (CP). Quasi-experimental, proof-of-concept study with between-groups comparison. Ambulant care facility, community center. Children and adolescents (N=65), consisting of those with CP (spastic and ataxic, n=26; Gross Motor Function Classification System I-III; mean age, 9.8y; 11 girls, 15 boys) and those who were typically developed (TD, n=39; mean age, 10.0y; 23 girls, 16 boys). IPT applied by a therapist to locations at the back and the head. As primary outcomes, head and trunk sway during self-paced walking were assessed by inertial measurement units. Secondary outcomes were average step length and gait speed. CP group: apex and occiput IPT reduced head velocity sway compared with thoracic IPT (both P=.04) irrespective of individuals' specific clinical symptoms. TD group: all testing conditions reduced head velocity sway compared with walking alone (all P≤.03), as well as in apex and occiput IPT compared with paired walking (both P≤.02). Deliberately light IPT at the apex of the head alters control of head sway in children and adolescents with CP. The effect of IPT varies as a function of contact location and acts differently in TD individuals. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Effects of myosin variants on interacting-heads motif explain distinct hypertrophic and dilated cardiomyopathy phenotypes

    PubMed Central

    Alamo, Lorenzo; Ware, James S; Pinto, Antonio; Gillilan, Richard E; Seidman, Jonathan G; Seidman, Christine E; Padrón, Raúl

    2017-01-01

    Cardiac β-myosin variants cause hypertrophic (HCM) or dilated (DCM) cardiomyopathy by disrupting sarcomere contraction and relaxation. The locations of variants on isolated myosin head structures predict contractility effects but not the prominent relaxation and energetic deficits that characterize HCM. During relaxation, pairs of myosins form interacting-heads motif (IHM) structures that with other sarcomere proteins establish an energy-saving, super-relaxed (SRX) state. Using a human β-cardiac myosin IHM quasi-atomic model, we defined interactions sites between adjacent myosin heads and associated protein partners, and then analyzed rare variants from 6112 HCM and 1315 DCM patients and 33,370 ExAC controls. HCM variants, 72% that changed electrostatic charges, disproportionately altered IHM interaction residues (expected 23%; HCM 54%, p=2.6×10−19; DCM 26%, p=0.66; controls 20%, p=0.23). HCM variant locations predict impaired IHM formation and stability, and attenuation of the SRX state - accounting for altered contractility, reduced diastolic relaxation, and increased energy consumption, that fully characterizes HCM pathogenesis. DOI: http://dx.doi.org/10.7554/eLife.24634.001 PMID:28606303

  18. A residue located at the junction of the head and stalk regions of measles virus fusion protein regulates membrane fusion by controlling conformational stability.

    PubMed

    Satoh, Yuto; Yonemori, Saeka; Hirose, Mitsuhiro; Shogaki, Hiroko; Wakimoto, Hiroshi; Kitagawa, Yoshinori; Gotoh, Bin; Shirai, Tsuyoshi; Takahashi, Ken-Ichi; Itoh, Masae

    2017-02-01

    The fusion (F) protein of measles virus performs refolding from the thermodynamically metastable prefusion form to the highly stable postfusion form via an activated unstable intermediate stage, to induce membrane fusion. Some amino acids involved in the fusion regulation cluster in the heptad repeat B (HR-B) domain of the stalk region, among which substitution of residue 465 by various amino acids revealed that fusion activity correlates well with its side chain length from the Cα (P<0.01) and van der Waals volume (P<0.001), except for Phe, Tyr, Trp, Pro and His carrying ring structures. Directed towards the head region, longer side chains of the non-ring-type 465 residues penetrate more deeply into the head region and may disturb the hydrophobic interaction between the stalk and head regions and cause destabilization of the molecule by lowering the energy barrier for refolding, which conferred the F protein enhanced fusion activity. Contrarily, the side chain of ring-type 465 residues turned away from the head region, resulting in not only no contact with the head region but also extensive coverage of the HR-B surface, which may prevent the dissociation of the HR-B bundle for initiation of membrane fusion and suppress fusion activity. Located in the HR-B domain just at the junction between the head and stalk regions, amino acid 465 is endowed with a possible ability to either destabilize or stabilize the F protein depending on its molecular volume and the direction of the side chain, regulating fusion activity of measles virus F protein.

  19. Wearable technology reveals gait compensations, unstable walking patterns and fatigue in people with Multiple Sclerosis.

    PubMed

    Psarakis, Michael; Greene, David; Cole, Michael H; Lord, Stephen R; Hoang, Phu; Brodie, Matthew A D

    2018-04-27

    People with Multiple Sclerosis (PwMS) often experience a decline in gait performance, which can compromise their independence and increase falls. Ankle joint contractures in PwMS are common and often result in compensatory gait patterns to accommodate reduced ankle range of motion (ROM). Using advances in wearable technology, the aim of this study was to quantify head and pelvis movement patterns that occur in PwMS with disability and determine how these secondary gait compensations impact on gait stability. Twelve healthy participants and twelve PwMS participated in the study. Head and pelvis movements were measured using two tri-axial accelerometers. Measures of gait compensation, mobility, variability, asymmetry, stability and fatigue were assessed during a six-minute walking test. Compared to healthy controls, PwMS had greater vertical asymmetry in their head and pelvic movements (Cohen's d=1.85 & 1.60). Lower harmonic ratios indicated that PwMS were more unstable than controls (Cohen's d=-1.61 to -3.06), even after adjusting for their slower walking speeds. In the PwMS, increased compensatory movements were correlated with reduced ankle active ROM (r=-0.71), higher disability (EDSS) scores (r=0.58), unstable gait (r=-0.76), reduced mobility (r=-0.76) and increased variability (r=0.83). Wearable device technology provides an efficient and reliable way to screen for excessive compensatory movements often present in PwMS and provides clinically-important information that impacts on mobility, stride time variability and gait stability. This information may help clinicians identify PwMS at high risk of falling and develop better rehabilitation interventions that, in addition to improving mobility, may help target the underlying causes of unstable gait. © 2018 Institute of Physics and Engineering in Medicine.

  20. Vestibular dysfunction in the adult CBA/CaJ mouse after lead and cadmium treatment

    PubMed Central

    Klimpel, Katarina E. M.; Lee, Min Young; King, W. Michael; Raphael, Yehoash; Schacht, Jochen; Neitzel, Richard L.

    2017-01-01

    OBJECTIVES The vestibular system allows the perception of position and motion and its dysfunction presents as motion impairment, vertigo and balance abnormalities, leading to debilitating psychological discomfort and difficulty performing daily tasks. Although declines and deficits in vestibular function have been noted in rats exposed to lead (Pb) and in humans exposed to Pb and cadmium (Cd), no studies have directly examined the pathological and pathophysiological effects upon the vestibular apparatus of the inner ear. METHODS Eighteen young adult mice were exposed through their drinking water (3 mM Pb, 300 μM Cd, or a control treatment) for 10 weeks. Before and after treatment, they underwent a vestibular assessment, consisting of a rotarod performance test and a novel head stability test to measure the vestibulocolic reflex. At the conclusion of the study, the utricles were analyzed immunohistologically for condition of hair cells and nerve fibers. RESULTS Increased levels of Pb exposure correlated with decreased head stability in space; no significant decline in performance on rotarod test was found. No damage to the hair cells or the nerve fibers of the utricle was observed in histology. CONCLUSIONS The young adult CBA/CaJ mouse is able to tolerate occupationally-relevant Pb and Cd exposure well, but the correlation between Pb exposure and reduced head stability suggests that Pb exposure causes a decline in vestibular function. PMID:27257108

  1. Head motion in humans alternating between straight and curved walking path: combination of stabilizing and anticipatory orienting mechanisms.

    PubMed

    Hicheur, Halim; Vieilledent, Stéphane; Berthoz, Alain

    Anticipatory head orientation relative to walking direction was investigated in humans. Subjects were asked to walk along a 20 m perimeter, figure of eight. The geometry of this path required subjects to steer their body according to both curvature variations (alternate straight with curved walking) and walking direction (clock wise and counter clock wise). In agreement with previous results obtained during different locomotor tasks [R. Grasso, S. Glasauer, Y. Takei, A. Berthoz, The predictive brain: anticipatory control of head direction for the steering of locomotion, NeuroReport 7 (1996) 1170-1174; R. Grasso, P. Prevost, Y.P. Ivanenko, A. Berthoz, Eye-head coordination for the steering of locomotion in humans: an anticipatory synergy, Neurosci. Lett. 253 (2) (1998) 115-118; T. Imai, S.T. Moore, T. Raphan, B. Cohen, Interaction of body, head, and eyes during walking and turning, Exp. Brain Res. 136 (2001) 1-18; P. Prevost, Y. Ivanenko, R. Grasso, A. Berthoz, Spatial invariance in anticipatory orienting behaviour during human navigation, Neurosci. Lett. 339 (2002) 243-247; G. Courtine, M. Schieppati, Human walking along a curved path. I. Body trajectory, segment orientation and the effect of vision, Eur. J. Neurosci. 18 (2003) 177-190], the head turned toward the future walking direction. This anticipatory head behaviour was continuously modulated by the geometrical variations of the path. Two main components were observed in the anticipatory head behaviour. One was related to the geometrical form of the path, the other to the transfer of body mass from one foot to the other during stepping. A clear modulation of the head deviation pattern was observed between walking on curved versus straight parts of the path: head orientation was influenced to a lesser extent by step alternation for curved path where a transient head fixation was observed. We also observed good symmetry in the head deviation profile, i.e. the head tended to anticipate the future walking direction with the same amplitude when turning to the left (29.75 +/- 7.41 degrees of maximum head deviation) or to the right (30.86 +/- 9.92 degrees ). These findings suggest a combination of motor strategies underlying head stabilization in space and more global orienting mechanisms for steering the whole body in the desired direction.

  2. Spatiotopic coding during dynamic head tilt

    PubMed Central

    Turi, Marco; Burr, David C.

    2016-01-01

    Humans maintain a stable representation of the visual world effortlessly, despite constant movements of the eyes, head, and body, across multiple planes. Whereas visual stability in the face of saccadic eye movements has been intensely researched, fewer studies have investigated retinal image transformations induced by head movements, especially in the frontal plane. Unlike head rotations in the horizontal and sagittal planes, tilting the head in the frontal plane is only partially counteracted by torsional eye movements and consequently induces a distortion of the retinal image to which we seem to be completely oblivious. One possible mechanism aiding perceptual stability is an active reconstruction of a spatiotopic map of the visual world, anchored in allocentric coordinates. To explore this possibility, we measured the positional motion aftereffect (PMAE; the apparent change in position after adaptation to motion) with head tilts of ∼42° between adaptation and test (to dissociate retinal from allocentric coordinates). The aftereffect was shown to have both a retinotopic and spatiotopic component. When tested with unpatterned Gaussian blobs rather than sinusoidal grating stimuli, the retinotopic component was greatly reduced, whereas the spatiotopic component remained. The results suggest that perceptual stability may be maintained at least partially through mechanisms involving spatiotopic coding. NEW & NOTEWORTHY Given that spatiotopic coding could play a key role in maintaining visual stability, we look for evidence of spatiotopic coding after retinal image transformations caused by head tilt. To this end, we measure the strength of the positional motion aftereffect (PMAE; previously shown to be largely spatiotopic after saccades) after large head tilts. We find that, as with eye movements, the spatial selectivity of the PMAE has a large spatiotopic component after head rotation. PMID:27903636

  3. Pilot Study: Measuring the Effects of Center of Gravity Shift on Postural Stability

    NASA Technical Reports Server (NTRS)

    Times-Marshall, Chelsea; Reschke, Millard

    2009-01-01

    It has been shown that astronauts returning from space often experience postural instability due to the stimulus rearrangement of the visual, vestibular, and proprioceptive systems. However, postural control may also be influenced by the head-ward shift in their center of gravity (CG) that occurs as a result of the expansion of their spinal column by as much as two inches during long duration space flight, as well as the CG shift that occurs from the Life Support Pack on the extra-vehicular activity (EVA) suit. This study investigated the effect on postural stability after (1) an immediate shift in the CG towards the head, (2) a 30 minute adaptation to the shifted CG, and (3) immediate shift of the CG back to normal, accomplished by donning and removing a modified backpack. We hypothesized that at each immediate shift in CG, postural performance will be compromised.

  4. Posture, head stability, and orientation recovery during vestibular regeneration in pigeons.

    PubMed

    Dickman, J David; Lim, Insook

    2004-09-01

    Compensatory behavior such as oculomotor, gaze, and postural responses that occur during movement largely depend upon a functioning vestibular system. In the present study, the initial loss and subsequent recovery of postural and head stability in pigeons undergoing vestibular regeneration were examined. Adult pigeons were trained to manipulate a straight run chamber to peck an illuminated key for fluid reward. Six behavioral measures assessing performance, posture, and head stability were quantified. These included run latency, steps (walking), path negotiation (lane changes), gaze saccades, head bobs, and head shakes. Once normative values were obtained for four birds, complete lesion of all receptor cells and denervation of the epithelia in the vestibular endorgans were produced using a single intralabyrinthine application of streptomycin sulfate. Each bird was then tested at specific times during regeneration and the same behavioral measures examined. At 7 days post-streptomycin treatment (PST), all birds exhibited severe postural and head instability, with tremors, head shakes, staggering, and circling predominating. No normal trial runs, walking, gaze saccades, or head bobs were present. Many of these dysfunctions persisted through 3-4 weeks PST. Gradually, tremor and head shakes diminished and were replaced with an increasing number of normal head bobs during steps and gaze saccades. Beginning at 4 weeks PST, but largely inaccurate, was the observed initiation of directed steps, less staggering, and some successful path negotiation. As regeneration progressed, spatial orientation and navigation ability increased and, by 49 days PST, most trials were successful. By 70 days PST, all birds had recovered to pretreatment levels. Thus, it was observed that ataxia must subside, coincident with normalized head and postural stability prior to the recovery of spatial orientation and path navigation recovery. Parallels in recovery were drawn to hair cell regeneration and afferent responsiveness, as inferred from present results and those in other investigations.

  5. Vestibular ablation and a semicircular canal prosthesis affect postural stability during head turns

    PubMed Central

    Thompson, Lara A.; Haburcakova, Csilla; Lewis, Richard F.

    2016-01-01

    In our study, we examined postural stability during head turns for two rhesus monkeys: one, single animal study contrasted normal and mild bilateral vestibular ablation and a second animal study contrasted severe bilateral vestibular ablation with and without prosthetic stimulation. The monkeys freely stood, unrestrained on a balance platform and made voluntary head turns between visual targets. To quantify each animals’ posture, motions of the head and trunk, as well as torque about the body’s center-of-mass, were measured. In the mildly ablated animal, we observed less foretrunk sway in comparison to the normal state. When the canal prosthesis provided electric stimulation to the severely ablated animal, it showed a decrease in trunk sway during head turns. Because the rhesus monkey with severe bilateral vestibular loss exhibited a decrease in trunk sway when receiving vestibular prosthetic stimulation, we propose that the prosthetic electrical stimulation partially restored head velocity information. Our results provide an indication that a semicircular canal prosthesis may be an effective way to improve postural stability in patients with severe peripheral vestibular dysfunction. PMID:27405997

  6. Tactile pavement for guiding walking direction: An assessment of heading direction and gait stability.

    PubMed

    Pluijter, Nanda; de Wit, Lieke P W; Bruijn, Sjoerd M; Plaisier, Myrthe A

    2015-10-01

    For maintaining heading direction while walking we heavily rely on vision. Therefore, walking in the absence of vision or with visual attention directed elsewhere potentially leads to dangerous situations. Here we investigated whether tactile information from the feet can be used as a (partial) substitute for vision in maintaining a stable heading direction. If so, participants should be better able to keep a constant heading direction on tactile pavement that indicates directionality than on regular flat pavement. However, such a pavement may also be destabilizing. Thus we asked participants to walk straight ahead on regular pavement, and on tactile pavement (tiles with ridges along the walking direction) while varying the amount of vision. We assessed the effects of the type of pavement as well as the amount of vision on the variability of the heading direction as well as gait stability. Both of these measures were calculated from accelerations and angular velocities recorded from a smartphone attached to the participants trunk. Results showed that on tactile pavement participants had a less variations in their heading direction than on regular pavement. The drawback, however, was that the tactile pavement used in this study decreased gait stability. In sum, tactile pavement can be used as a partial substitute for vision in maintaining heading direction, but it can also decrease gait stability. Future work should focus on designing tactile pavement that does provided directional clues, but is less destabilizing. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Commande de vol non lineaire d'un drone a voilure fixe par la methode du backstepping

    NASA Astrophysics Data System (ADS)

    Finoki, Edouard

    This thesis describes the design of a non-linear controller for a UAV using the backstepping method. It is a fixed-wing UAV, the NexSTAR ARF from HobbicoRTM. The aim is to find the expressions of the aileron, the elevator, and the rudder deflection in order to command the flight path angle, the heading angle and the sideslip angle. Controlling the flight path angle allows a steady, climb or descent flight, controlling the heading cap allows to choose the heading and annul the sideslip angle allows an efficient flight. A good technical control has to ensure the stability of the system and provide optimal performances. Backstepping interlaces the choice of a Lyapunov function with the design of feedback control. This control technique works with the true non-linear model without any approximation. The procedure is to transform intermediate state variables into virtual inputs which will control other state variables. Advantages of this technique are its recursivity, its minimum control effort and its cascaded structure that allows dividing a high order system into several simpler lower order systems. To design this non-linear controller, a non-linear model of the UAV was used. Equations of motion are very accurate, aerodynamic coefficients result from interpolations between several essential variables in flight. The controller has been implemented in Matlab/Simulink and FlightGear.

  8. Gaze Stabilization During Locomotion Requires Full Body Coordination

    NASA Technical Reports Server (NTRS)

    Mulavara, A. P.; Miller, C. A.; Houser, J.; Richards, J. T.; Bloomberg, J. J.

    2001-01-01

    Maintaining gaze stabilization during locomotion places substantial demands on multiple sensorimotor subsystems for precise coordination. Gaze stabilization during locomotion requires eye-head-trunk coordination (Bloomberg, et al., 1997) as well as the regulation of energy flow or shock-wave transmission through the body at high impact phases with the support surface (McDonald, et al., 1997). Allowing these excessive transmissions of energy to reach the head may compromise gaze stability. Impairments in these mechanisms may lead to the oscillopsia and decreased dynamic visual acuity seen in crewmembers returning from short and long duration spaceflight, as well as in patients with vestibular disorders (Hillman, et al., 1999). Thus, we hypothesize that stabilized gaze during locomotion results from full-body coordination of the eye-head-trunk system combined with the lower limb apparatus. The goal of this study was to determine how multiple, interdependent full- body sensorimotor subsystems aiding gaze stabilization during locomotion are functionally coordinated, and how they adaptively respond to spaceffight.

  9. The head-mounted microscope.

    PubMed

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. Impaction Force Influences Taper-Trunnion Stability in Total Hip Arthroplasty.

    PubMed

    Danoff, Jonathan R; Longaray, Jason; Rajaravivarma, Raga; Gopalakrishnan, Ananthkrishnan; Chen, Antonia F; Hozack, William J

    2018-07-01

    This study investigated the influence of femoral head impaction force, number of head strikes, the energy sequence of head strikes, and head offset on the strength of the taper-trunnion junction. Thirty titanium-alloy trunnions were mated with 36-mm zero-offset cobalt-chromium femoral heads of corresponding taper angle. A drop tower impacted the head with 2.5J or 8.25J, resulting in 6 kN or 14 kN impaction force, respectively, in a single strike or combinations of 6 kN + 14 kN or 14 kN + 14 kN. In addition, ten 36-mm heads with -5 and +5 offset were impacted with sequential 14 kN + 14 kN strikes. Heads were subsequently disassembled using a screw-driven mechanical testing frame, and peak distraction force was recorded. Femoral head pull-off force was 45% the strike force, and heads struck with a single 14 kN impact showed a pull-off force twice that of the 6 kN group. Two head strikes with the same force did not improve pull-off force for either 6 kN (P = .90) or 14 kN (P = .90). If the forces of the 2 impactions varied, but either impact measured 14 kN, a 51% higher pull-off force was found compared to impactions of either 6 kN or 6 kN + 6 kN. Femoral head offset did not significantly change the pull-off force among -5, 0, and +5 heads (P = .37). Femoral head impaction force influenced femoral head trunnion-taper stability, whereas offset did not affect pull-off force. Multiple head strikes did not add additional stability, as long as a single strike achieved 14 kN force at the mallet-head impactor interface. Insufficient impaction force may lead to inadequate engagement of the trunnion-taper junction. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Head-Disk Interface Technology: Challenges and Approaches

    NASA Astrophysics Data System (ADS)

    Liu, Bo

    Magnetic hard disk drive (HDD) technology is believed to be one of the most successful examples of modern mechatronics systems. The mechanical beauty of magnetic HDD includes simple but super high accuracy positioning head, positioning technology, high speed and stability spindle motor technology, and head-disk interface technology which keeps the millimeter sized slider flying over a disk surface at nanometer level slider-disk spacing. This paper addresses the challenges and possible approaches on how to further reduce the slider disk spacing whilst retaining the stability and robustness level of head-disk systems for future advanced magnetic disk drives.

  12. Postural compensation for vestibular loss and implications for rehabilitation.

    PubMed

    Horak, Fay B

    2010-01-01

    This chapter summarizes the role of the vestibular system in postural control so that specific and effective rehabilitation can be designed that facilitates compensation for loss of vestibular function. Patients with bilateral or unilateral loss of peripheral vestibular function are exposed to surface perturbations to quantify automatic postural responses. Studies also evaluated the effects of audio- and vibrotactile-biofeedback to improve stability in stance and gait. The most important role of vestibular information for postural control is to control orientation of the head and trunk in space with respect to gravitoinertial forces, particularly when balancing on unstable surfaces. Vestibular sensory references are particularly important for postural control at high frequencies and velocities of self-motion, to reduce trunk drift and variability, to provide an external reference frame for the trunk and head in space; and to uncouple coordination of the trunk from the legs and the head-in-space from the body CoM. The goal of balance rehabilitation for patients with vestibular loss is to help patients 1) use remaining vestibular function, 2) depend upon surface somatosensory information as their primary postural sensory system, 3) learn to use stable visual references, and 4) identify efficient and effective postural movement strategies.

  13. Hemianopic and Quadrantanopic Field Loss, Eye and Head Movements, and Driving

    PubMed Central

    McGwin, Gerald; Elgin, Jennifer; Vaphiades, Michael S.; Braswell, Ronald A.; DeCarlo, Dawn K.; Kline, Lanning B.; Owsley, Cynthia

    2011-01-01

    Purpose. To compare eye and head movements, lane keeping, and vehicle control of drivers with hemianopic and quadrantanopic field defects with controls, and to identify differences in these parameters between hemianopic and quadrantanopic drivers rated safe to drive by a clinical driving rehabilitation specialist compared with those rated as unsafe. Methods. Eye and head movements and lane keeping were rated in 22 persons with homonymous hemianopic defects and 8 with quadrantanopic defects (mean age, 53 years) who were ≥6 months post-injury and 30 persons with normal fields (mean age, 53 years). All were licensed to drive and were current drivers or aimed to resume driving. Participants drove a 6.3-mile route along non-interstate city roads under in-traffic conditions. Vehicle control was assessed objectively by vehicle instrumentation for speed, braking, acceleration, and cornering. Results. As a group, drivers with hemianopic or quadrantanopic defects drove slower, exhibited less excessive cornering or acceleration, and executed more shoulder movements than the controls. Those drivers with hemianopic or quadrantanopic defects rated as safe also made more head movements into their blind field, received superior ratings regarding eye movement extent and lane position stability, and exhibited less sudden braking and drove faster than those rated unsafe. Conclusions. Persons with hemianopic and quadrantanopic defects rated as safe to drive compensated by making more head movements into their blind field, combined with more stable lane keeping and less sudden braking. Future research should evaluate whether these characteristics could be trained in rehabilitation programs aimed at improving driving safety in this population. PMID:21367969

  14. Helmet-Mounted Display Design Guide

    NASA Technical Reports Server (NTRS)

    Newman, Richard L.; Greeley, Kevin W.

    1997-01-01

    Helmet Mounted Displays (HMDs) present flight, navigation, and weapon information in the pilot's line of sight. The HMD was developed to allow the pilot to retain aircraft and weapon information while looking off boresight. This document reviews current state of the art in HMDs and presents a design guide for the HMD engineer in identifying several critical HMD issues: symbol stabilization, inadequate definitions, undefined symbol drive laws, helmet considerations, and Field Of View (FOV) vs. resolution tradeoff requirements. In particular, display latency is a key issue for HMDs. In addition to requiring further experimental studies, it impacts the definition and control law issues. Symbol stabilization is also critical. In the case of the Apache helicopter, the lack of compensation for pilot head motion creates excessive workload during hovering and Nap Of the Earth (NOE) flight. This translates into excessive training requirements. There is no agreed upon set of definitions or descriptions for how HMD symbols are driven to compensate for pilot head motion. A set of definitions is proposed to address this. There are several specific areas where simulation and flight experiments are needed: development of hover and NOE symbologies which compensate for pilot head movement; display latency and sampling, and the tradeoff between FOV, sensor resolution and symbology.

  15. Head-bobbing behavior in foraging Whooping Cranes

    USGS Publications Warehouse

    Cronin, T.; Kinloch, M.; Olsen, Glenn H.

    2006-01-01

    Many species of cursorial birds 'head-bob', that is, they alternately thrust the head forward, then hold it stiII as they walk. Such a motion stabilizes visual fields intermittently and could be critical for visual search; yet the time available for stabilization vs. forward thrust varies with walking speed. Whooping Cranes (Grus americana) are extremely tall birds that visually search the ground for seeds, berries, and small prey. We examined head movements in unrestrained Whooping Cranes using digital video subsequently analyzed with a computer graphical overlay. When foraging, the cranes walk at speeds that allow the head to be held still for at least 50% of the time. This behavior is thought to balance the two needs for covering as much ground as possible and for maximizing the time for visual fixation of the ground in the search for prey. Our results strongly suggest that in cranes, and probably many other bird species, visual fixation of the ground is required for object detection and identification. The thrust phase of the head-bobbing cycle is probably also important for vision. As the head moves forward, the movement generates visual flow and motion parallax, providing visual cues for distances and the relative locations of objects. The eyes commonly change their point of fixation when the head is moving too, suggesting that they remain visually competent throughout the entire cycle of thrust and stabilization.

  16. Radar cross calibration investigation TAMU radar polarimeter calibration measurements

    NASA Technical Reports Server (NTRS)

    Blanchard, A. J.; Newton, R. W.; Bong, S.; Kronke, C.; Warren, G. L.; Carey, D.

    1982-01-01

    A short pulse, 20 MHz bandwidth, three frequency radar polarimeter system (RPS) operates at center frequencies of 10.003 GHz, 4.75 GHz, and 1.6 GHz and utilizes dual polarized transmit and receive antennas for each frequency. The basic lay-out of the RPS is different from other truck mounted systems in that it uses a pulse compression IF section common to all three RF heads. Separate transmit and receive antennas are used to improve the cross-polarization isolation at each particular frequency. The receive is a digitally controlled gain modulated subsystem and is interfaced directly with a microprocesser computer for control and data manipulation. Antenna focusing distance, focusing each antenna pair, rf head stability, and polarization characteristics of RPS antennas are discussed. Platform and data acquisition procedures are described.

  17. Postural Control in Bilateral Vestibular Failure: Its Relation to Visual, Proprioceptive, Vestibular, and Cognitive Input.

    PubMed

    Sprenger, Andreas; Wojak, Jann F; Jandl, Nico M; Helmchen, Christoph

    2017-01-01

    Patients with bilateral vestibular failure (BVF) suffer from postural and gait unsteadiness with an increased risk of falls. The aim of this study was to elucidate the differential role of otolith, semicircular canal (SSC), visual, proprioceptive, and cognitive influences on the postural stability of BVF patients. Center-of-pressure displacements were recorded by posturography under six conditions: target visibility; tonic head positions in the pitch plane; horizontal head shaking; sensory deprivation; dual task; and tandem stance. Between-group analysis revealed larger postural sway in BVF patients on eye closure; but with the eyes open, BVF did not differ from healthy controls (HCs). Head tilts and horizontal head shaking increased sway but did not differ between groups. In the dual task condition, BVF patients maintained posture indistinguishable from controls. On foam and tandem stance, postural sway was larger in BVF, even with the eyes open. The best predictor for the severity of bilateral vestibulopathy was standing on foam with eyes closed. Postural control of our BVF was indistinguishable from HCs once visual and proprioceptive feedback is provided. This distinguishes them from patients with vestibulo-cerebellar disorders or functional dizziness. It confirms previous reports and explains that postural unsteadiness of BVF patients can be missed easily if not examined by conditions of visual and/or proprioceptive deprivation. In fact, the best predictor for vestibular hypofunction (VOR gain) was examining patients standing on foam with the eyes closed. Postural sway in that condition increased with the severity of vestibular impairment but not with disease duration. In the absence of visual control, impaired otolith input destabilizes BVF with head retroflexion. Stimulating deficient SSC does not distinguish patients from controls possibly reflecting a shift of intersensory weighing toward proprioceptive-guided postural control. Accordingly, proprioceptive deprivation heavily destabilizes BVF, even when visual control is provided.

  18. Postural Control in Bilateral Vestibular Failure: Its Relation to Visual, Proprioceptive, Vestibular, and Cognitive Input

    PubMed Central

    Sprenger, Andreas; Wojak, Jann F.; Jandl, Nico M.; Helmchen, Christoph

    2017-01-01

    Patients with bilateral vestibular failure (BVF) suffer from postural and gait unsteadiness with an increased risk of falls. The aim of this study was to elucidate the differential role of otolith, semicircular canal (SSC), visual, proprioceptive, and cognitive influences on the postural stability of BVF patients. Center-of-pressure displacements were recorded by posturography under six conditions: target visibility; tonic head positions in the pitch plane; horizontal head shaking; sensory deprivation; dual task; and tandem stance. Between-group analysis revealed larger postural sway in BVF patients on eye closure; but with the eyes open, BVF did not differ from healthy controls (HCs). Head tilts and horizontal head shaking increased sway but did not differ between groups. In the dual task condition, BVF patients maintained posture indistinguishable from controls. On foam and tandem stance, postural sway was larger in BVF, even with the eyes open. The best predictor for the severity of bilateral vestibulopathy was standing on foam with eyes closed. Postural control of our BVF was indistinguishable from HCs once visual and proprioceptive feedback is provided. This distinguishes them from patients with vestibulo-cerebellar disorders or functional dizziness. It confirms previous reports and explains that postural unsteadiness of BVF patients can be missed easily if not examined by conditions of visual and/or proprioceptive deprivation. In fact, the best predictor for vestibular hypofunction (VOR gain) was examining patients standing on foam with the eyes closed. Postural sway in that condition increased with the severity of vestibular impairment but not with disease duration. In the absence of visual control, impaired otolith input destabilizes BVF with head retroflexion. Stimulating deficient SSC does not distinguish patients from controls possibly reflecting a shift of intersensory weighing toward proprioceptive-guided postural control. Accordingly, proprioceptive deprivation heavily destabilizes BVF, even when visual control is provided. PMID:28919878

  19. Comparison of Postural Recovery Following Short and Long Duration Spaceflights

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Fiedler, J.; Taylor, L. C.; Kozlovskaya, I.; Black, F. O.; Paloski, W. H.

    2010-01-01

    INTRODUCTION: Post-flight postural ataxia reflects adaptive changes to vestibulo-spinal reflexes and control strategies adopted for movement in weightlessness. Quantitative measures obtained during computerized dynamic posturography (CDP) from US and Russian programs provide insight into the effect of spaceflight duration in terms of both the initial decrements and recovery of postural stability. METHODS: CDP was obtained on 117 crewmembers following Shuttle flights lasting 4-17 days, and on 64 crewmembers following long-duration missions lasting 48-380 days. Although the number and timing of sessions varied, the goal was to characterize postural recovery pooling similar measures from different research and flight medicine programs. This report focuses on eyes closed, head erect conditions with either a fixed or sway-referenced base of support. A smaller subset of subjects repeated the sway-referenced condition while making pitch head movements (+/- 20deg at 0.33Hz). Equilibrium scores were derived from peak-to-peak anterior-posterior sway. Fall probability was modeled using Bayesian statistical methods to estimate parameters of a logit function. RESULTS: The standard Romberg condition was the least sensitive. Longer duration flights led to larger decrements in stability with sway-reference support during the first 1-2 days, although the timecourse of recovery was similar across flight duration with head erect. Head movements led to increased incidence of falls during the first week, with a significantly longer recovery following long duration flights. CONCLUSIONS: The diagnostic assessment of postural instability, and differences in the timecourse of postural recovery between short and long flight durations, are more pronounced during unstable support conditions requiring active head movements.

  20. Neck Strength Imbalance Correlates With Increased Head Acceleration in Soccer Heading

    PubMed Central

    Dezman, Zachary D.W.; Ledet, Eric H.; Kerr, Hamish A.

    2013-01-01

    Background: Soccer heading is using the head to directly contact the ball, often to advance the ball down the field or score. It is a skill fundamental to the game, yet it has come under scrutiny. Repeated subclinical effects of heading may compound over time, resulting in neurologic deficits. Greater head accelerations are linked to brain injury. Developing an understanding of how the neck muscles help stabilize and reduce head acceleration during impact may help prevent brain injury. Hypothesis: Neck strength imbalance correlates to increasing head acceleration during impact while heading a soccer ball. Study Design: Observational laboratory investigation. Methods: Sixteen Division I and II collegiate soccer players headed a ball in a controlled indoor laboratory setting while player motions were recorded by a 14-camera Vicon MX motion capture system. Neck flexor and extensor strength of each player was measured using a spring-type clinical dynamometer. Results: Players were served soccer balls by hand at a mean velocity of 4.29 m/s (±0.74 m/s). Players returned the ball to the server using a heading maneuver at a mean velocity of 5.48 m/s (±1.18 m/s). Mean neck strength difference was positively correlated with angular head acceleration (rho = 0.497; P = 0.05), with a trend toward significance for linear head acceleration (rho = 0.485; P = 0.057). Conclusion: This study suggests that symmetrical strength in neck flexors and extensors reduces head acceleration experienced during low-velocity heading in experienced collegiate players. Clinical Relevance: Balanced neck strength may reduce head acceleration cumulative subclinical injury. Since neck strength is a measureable and amenable strength training intervention, this may represent a modifiable intrinsic risk factor for injury. PMID:24459547

  1. Functional training improves club head speed and functional fitness in older golfers.

    PubMed

    Thompson, Christian J; Cobb, Karen Myers; Blackwell, John

    2007-02-01

    Functional training programs have been used in a variety of rehabilitation settings with documented success. Based on that success, the concept of functional training has gained popularity in applied fitness settings to enhance sport performance. However, there has been little or no research studying the efficacy of functional training programs on the improvement of sport performance or functional fitness. Thus, it was the purpose of this study to determine the effect of a progressive functional training program on club head speed and functional fitness in older male golfers. Eighteen male golfers (age: 70.7 +/- 9.1 [SD] years) were randomly assigned to an exercise (N = 11) or control (N = 7) group. The exercise group participated in an 8-week progressive functional training program including flexibility exercises, core stability exercises, balance exercises, and resistance exercises. Pre- and postmeasurements included club head speed of a driver by radar (exercise and Control) and Fullerton Senior Fitness Test measurements (exercise only). One-way analysis of covariance was performed on club head speed measurements using pretest measurements as the covariate. Paired t-tests were performed to analyze Senior Fitness Test variables. After the intervention, maximal club head speed increased in the exercise group (127.3 +/- 13.4 to 133.6 +/- 14.2 km x hr(-1)) compared with the control group (134.5 +/- 14.6 to 133.3 +/- 11.2 km x hr(-1); p < 0.05). Additionally, improvements (p < 0.05) were detected for most Senior Fitness Test variables in the exercise group. In summary, this functional training program resulted in significant improvements in club head speed and several components of functional fitness. Future research should continue to examine the effect of functional training programs on sport performance and functional fitness in older adults.

  2. Procedures for Behavioral Experiments in Head-Fixed Mice

    PubMed Central

    Guo, Zengcai V.; Hires, S. Andrew; Li, Nuo; O'Connor, Daniel H.; Komiyama, Takaki; Ophir, Eran; Huber, Daniel; Bonardi, Claudia; Morandell, Karin; Gutnisky, Diego; Peron, Simon; Xu, Ning-long; Cox, James; Svoboda, Karel

    2014-01-01

    The mouse is an increasingly prominent model for the analysis of mammalian neuronal circuits. Neural circuits ultimately have to be probed during behaviors that engage the circuits. Linking circuit dynamics to behavior requires precise control of sensory stimuli and measurement of body movements. Head-fixation has been used for behavioral research, particularly in non-human primates, to facilitate precise stimulus control, behavioral monitoring and neural recording. However, choice-based, perceptual decision tasks by head-fixed mice have only recently been introduced. Training mice relies on motivating mice using water restriction. Here we describe procedures for head-fixation, water restriction and behavioral training for head-fixed mice, with a focus on active, whisker-based tactile behaviors. In these experiments mice had restricted access to water (typically 1 ml/day). After ten days of water restriction, body weight stabilized at approximately 80% of initial weight. At that point mice were trained to discriminate sensory stimuli using operant conditioning. Head-fixed mice reported stimuli by licking in go/no-go tasks and also using a forced choice paradigm using a dual lickport. In some cases mice learned to discriminate sensory stimuli in a few trials within the first behavioral session. Delay epochs lasting a second or more were used to separate sensation (e.g. tactile exploration) and action (i.e. licking). Mice performed a variety of perceptual decision tasks with high performance for hundreds of trials per behavioral session. Up to four months of continuous water restriction showed no adverse health effects. Behavioral performance correlated with the degree of water restriction, supporting the importance of controlling access to water. These behavioral paradigms can be combined with cellular resolution imaging, random access photostimulation, and whole cell recordings. PMID:24520413

  3. Effect of the Protein Hydrolysate from Shrimp Head on Freeze-Induced Denaturation of Fish Myofibrillar Protein

    NASA Astrophysics Data System (ADS)

    Ruttanapornvareesakul, Yaowalux; Hara, Kenji; Osatomi, Kiyoshi; Nozaki, Yukinori; Osako, Kazufumi; Kongpun, Orawan

    Three species of shrimp heads from commercial industry waste were hydrolyzed by enzymatic treatment using protease. Shrimp head protein hydrolysate (SHPH) was added to wanieso lizardfish myofibrils at 5% (dry weight/wet weight) as natural cryoprotectant. The effects of SHPH on the state of water and the freeze denaturation of wanieso lizardfish myotibrils during frozen storage at-25°C were evaluated by determining the amount of unfreezable water and Ca-ATPase activity. Their effects were compared with those of sodium glutamate (Na-Glu) and without additive as the control. The amount of unfreezable water of myofibri1s with SHPH was higher than that of the control throughout the frozen storage for 120 days. Ca-ATPase activity of myofibrils with SHPH decreased slowly compared to that of the control, although the suppressive effects of SHPH were less than that of Na-Glu. The suppressive effects of SHPH were irrespective of shrimp species. Close correlation between the amount of unfreezable water and Ca-ATPase activity was observed. These results suggested that SHPH could prevent the freeze-induced denaturation of fish myofibrils during frozen storage by stabilizing hydration water surrounding myofibrils.

  4. [Strategies for simultaneous control of the equilibrium and of the head position during the raising movement of a leg].

    PubMed

    Mouchnino, L; Aurenty, R; Massion, J; Pedotti, A

    1991-01-01

    The coordination between equilibrium control and the ability to maintain the position of given segments (head, trunk) was studied in standing subjects, instructed to raise one leg laterally at an angle of 45 degrees in response to a light. Two sources of light placed at eye level indicated the side on which the movement was to be performed. Two populations were compared: naive subjects and dancers. Two control strategies were identified. An "inclination" strategy was used by the naive subjects. This consisted of an external rotation of the body around the antero-posterior ankle joint axis; a counter-rotation of the head with respect to the trunk was observed, which ensured some stabilization in the horizontal plane of the interorbital line. A "translation" strategy was used by the dancers. Here the external rotation of the leg around the ankle joint was associated with a feed-forward counter-rotation of the trunk around the coxofemoral joint so that the horizontality of the interorbital line and the verticality of the trunk axis were maintained. This new coordination results from a long-term training and indicates that a new motor program has been elaborated.

  5. Trunk, head, and step characteristics during normal and narrow-based walking under deteriorated sensory conditions.

    PubMed

    Deshpande, Nandini; Zhang, Fang

    2014-01-01

    The ability to maintain stability in the frontal plane (medialateral direction) while walking is commonly included as a component of motor performance assessment. Postural control in the frontal plane may deteriorate faster and earlier with increasing age, compared to that in the sagittal plane (anteroposterior direction). Fifteen young (20-30 years old) and 15 older (>65 years old) healthy participants were recruited to investigate age-related differences in postural control during the normal and narrow-based walking when performed under suboptimal vestibular and lower limb somatosensory conditions achieved by galvanic stimulation and compliant surfaces, respectively. Gait speed decreased in the narrow-based walking condition, with larger decrease in the elderly (by 6%). In the elderly head roll increased with perturbed vestibular information in impaired somatosensory condition (by 40.70%). In both age groups trunk roll increased under impaired somatosensation in the narrow-based walking condition (by 43.62%) but not in normal walking condition. Older participants adopted a more cautious strategy characterized by lower walking speed when walking on a narrow base and exhibited deteriorated integrative ability of the CNS for head control. Accurate lower limb somatosensation may play a critical role in narrow-based walking.

  6. A magnetic tether system to investigate visual and olfactory mediated flight control in Drosophila.

    PubMed

    Duistermars, Brian J; Frye, Mark

    2008-11-21

    It has been clear for many years that insects use visual cues to stabilize their heading in a wind stream. Many animals track odors carried in the wind. As such, visual stabilization of upwind tracking directly aids in odor tracking. But do olfactory signals directly influence visual tracking behavior independently from wind cues? Also, the recent deluge of research on the neurophysiology and neurobehavioral genetics of olfaction in Drosophila has motivated ever more technically sophisticated and quantitative behavioral assays. Here, we modified a magnetic tether system originally devised for vision experiments by equipping the arena with narrow laminar flow odor plumes. A fly is glued to a small steel pin and suspended in a magnetic field that enables it to yaw freely. Small diameter food odor plumes are directed downward over the fly's head, eliciting stable tracking by a hungry fly. Here we focus on the critical mechanics of tethering, aligning the magnets, devising the odor plume, and confirming stable odor tracking.

  7. Head-bobbing behavior in walking whooping cranes (Grus americana) and sandhill cranes (Grus canadensis)

    USGS Publications Warehouse

    Cronin, Thomas W.; Kinloch, Matthew R.; Olsen, Glenn H.

    2007-01-01

    Head-bobbing is a common and characteristic behavior of walking birds. While the activity could have a relatively minor biomechanical function, for balance and stabilization of gait, head-bobbing is thought to be primarily a visual behavior in which fixation of gaze alternates with a forward movement that generates visual flow. We studied head-bobbing in locomoting whooping cranes (Grus americana) and sandhill cranes (Grus canadensis), using food strewn on the ground to motivate them to walk or run. When the cranes walked, head-bobbing proceeded in a four-step sequence that was closely linked to the stepping cycle. The time available for gaze stabilization decreased with travel speed, and running cranes did not head-bob at all. As a crane extended its bill towards the ground for food, it also exhibited a series of short head-bobs that were not associated with forward travel. Head-bobbing is a flexible behavior that varies with gait and with visual search, most notably as the cranes prepare to strike with the bill.

  8. Effects of environmental disturbance on phenotypic variation: an integrated assessment of canalization, developmental stability, modularity, and allometry in lizard head shape.

    PubMed

    Lazić, Marko M; Carretero, Miguel A; Crnobrnja-Isailović, Jelka; Kaliontzopoulou, Antigoni

    2015-01-01

    When populations experience suboptimal conditions, the mechanisms involved in the regulation of phenotypic variation can be challenged, resulting in increased phenotypic variance. This kind of disturbance can be diagnosed by using morphometric tools to study morphological patterns at different hierarchical levels and evaluate canalization, developmental stability, integration, modularity, and allometry. We assess the effect of urbanization on phenotypic variation in the common wall lizard (Podarcis muralis) by using geometric morphometrics to assess disturbance to head shape development. The head shapes of urban lizards were more variable and less symmetric, suggesting that urban living is more likely to disturb development. Head shape variation was congruent within and across individuals, which indicated that canalization and developmental stability are two related phenomena in these organisms. Furthermore, urban lizards exhibited smaller mean head sizes, divergent size-shape allometries, and increased deviation from within-group allometric lines. This suggests that mechanisms regulating head shape allometry may also be disrupted. The integrated evaluation of several measures of developmental instability at different hierarchical levels, which provided in this case congruent results, can be a powerful methodological guide for future studies, as it enhances the detection of environmental disturbances on phenotypic variation and aids biological interpretation of the results.

  9. Vision-based flight control in the hawkmoth Hyles lineata

    PubMed Central

    Windsor, Shane P.; Bomphrey, Richard J.; Taylor, Graham K.

    2014-01-01

    Vision is a key sensory modality for flying insects, playing an important role in guidance, navigation and control. Here, we use a virtual-reality flight simulator to measure the optomotor responses of the hawkmoth Hyles lineata, and use a published linear-time invariant model of the flight dynamics to interpret the function of the measured responses in flight stabilization and control. We recorded the forces and moments produced during oscillation of the visual field in roll, pitch and yaw, varying the temporal frequency, amplitude or spatial frequency of the stimulus. The moths’ responses were strongly dependent upon contrast frequency, as expected if the optomotor system uses correlation-type motion detectors to sense self-motion. The flight dynamics model predicts that roll angle feedback is needed to stabilize the lateral dynamics, and that a combination of pitch angle and pitch rate feedback is most effective in stabilizing the longitudinal dynamics. The moths’ responses to roll and pitch stimuli coincided qualitatively with these functional predictions. The moths produced coupled roll and yaw moments in response to yaw stimuli, which could help to reduce the energetic cost of correcting heading. Our results emphasize the close relationship between physics and physiology in the stabilization of insect flight. PMID:24335557

  10. Vision-based flight control in the hawkmoth Hyles lineata.

    PubMed

    Windsor, Shane P; Bomphrey, Richard J; Taylor, Graham K

    2014-02-06

    Vision is a key sensory modality for flying insects, playing an important role in guidance, navigation and control. Here, we use a virtual-reality flight simulator to measure the optomotor responses of the hawkmoth Hyles lineata, and use a published linear-time invariant model of the flight dynamics to interpret the function of the measured responses in flight stabilization and control. We recorded the forces and moments produced during oscillation of the visual field in roll, pitch and yaw, varying the temporal frequency, amplitude or spatial frequency of the stimulus. The moths' responses were strongly dependent upon contrast frequency, as expected if the optomotor system uses correlation-type motion detectors to sense self-motion. The flight dynamics model predicts that roll angle feedback is needed to stabilize the lateral dynamics, and that a combination of pitch angle and pitch rate feedback is most effective in stabilizing the longitudinal dynamics. The moths' responses to roll and pitch stimuli coincided qualitatively with these functional predictions. The moths produced coupled roll and yaw moments in response to yaw stimuli, which could help to reduce the energetic cost of correcting heading. Our results emphasize the close relationship between physics and physiology in the stabilization of insect flight.

  11. Assessing Sensorimotor Function Following ISS with Computerized Dynamic Posturography.

    PubMed

    Wood, Scott J; Paloski, William H; Clark, Jonathan B

    2015-12-01

    Postflight postural ataxia reflects both the control strategies adopted for movement in microgravity and the direct effects of deconditioning. Computerized dynamic posturography (CDP) has been used during the first decade of the International Space Station (ISS) expeditions to quantify the initial postflight decrements and recovery of postural stability. The CDP data were obtained on 37 crewmembers as part of their pre- and postflight medical examinations. Sensory organization tests evaluated the ability to make effective use of (or suppress inappropriate) visual, vestibular, and somatosensory information for balance control. This report focuses on eyes closed conditions with either a fixed or sway-referenced base of support, with the head erect or during pitch-head tilts (± 20° at 0.33 Hz). Equilibrium scores were derived from peak-to-peak anterior-posterior sway. Motor-control tests were also used to evaluate a crewmember's ability to automatically recover from unexpected support-surface perturbations. The standard Romberg condition was the least sensitive. Dynamic head tilts led to increased incidence of falls and revealed significantly longer recovery than head-erect conditions. Improvements in postflight postural performance during the later expeditions may be attributable to higher preflight baselines and/or advanced exercise capabilities aboard the ISS. The diagnostic assessment of postural instability is more pronounced during unstable-support conditions requiring active head movements. In addition to supporting return-to-duty decisions by flight surgeons, the CDP provides a standardized sensorimotor measure that can be used to evaluate the effectiveness of countermeasures designed to either minimize deconditioning on orbit or promote reconditioning upon return to Earth.

  12. Discovering the flight autostabilizer of fruit flies by inducing aerial stumbles

    PubMed Central

    Ristroph, Leif; Bergou, Attila J.; Ristroph, Gunnar; Coumes, Katherine; Berman, Gordon J.; Guckenheimer, John; Wang, Z. Jane; Cohen, Itai

    2010-01-01

    Just as the Wright brothers implemented controls to achieve stable airplane flight, flying insects have evolved behavioral strategies that ensure recovery from flight disturbances. Pioneering studies performed on tethered and dissected insects demonstrate that the sensory, neurological, and musculoskeletal systems play important roles in flight control. Such studies, however, cannot produce an integrative model of insect flight stability because they do not incorporate the interaction of these systems with free-flight aerodynamics. We directly investigate control and stability through the application of torque impulses to freely flying fruit flies (Drosophila melanogaster) and measurement of their behavioral response. High-speed video and a new motion tracking method capture the aerial “stumble,” and we discover that flies respond to gentle disturbances by accurately returning to their original orientation. These insects take advantage of a stabilizing aerodynamic influence and active torque generation to recover their heading to within 2° in < 60 ms. To explain this recovery behavior, we form a feedback control model that includes the fly’s ability to sense body rotations, process this information, and actuate the wing motions that generate corrective aerodynamic torque. Thus, like early man-made aircraft and modern fighter jets, the fruit fly employs an automatic stabilization scheme that reacts to short time-scale disturbances. PMID:20194789

  13. Discovering the flight autostabilizer of fruit flies by inducing aerial stumbles.

    PubMed

    Ristroph, Leif; Bergou, Attila J; Ristroph, Gunnar; Coumes, Katherine; Berman, Gordon J; Guckenheimer, John; Wang, Z Jane; Cohen, Itai

    2010-03-16

    Just as the Wright brothers implemented controls to achieve stable airplane flight, flying insects have evolved behavioral strategies that ensure recovery from flight disturbances. Pioneering studies performed on tethered and dissected insects demonstrate that the sensory, neurological, and musculoskeletal systems play important roles in flight control. Such studies, however, cannot produce an integrative model of insect flight stability because they do not incorporate the interaction of these systems with free-flight aerodynamics. We directly investigate control and stability through the application of torque impulses to freely flying fruit flies (Drosophila melanogaster) and measurement of their behavioral response. High-speed video and a new motion tracking method capture the aerial "stumble," and we discover that flies respond to gentle disturbances by accurately returning to their original orientation. These insects take advantage of a stabilizing aerodynamic influence and active torque generation to recover their heading to within 2 degrees in < 60 ms. To explain this recovery behavior, we form a feedback control model that includes the fly's ability to sense body rotations, process this information, and actuate the wing motions that generate corrective aerodynamic torque. Thus, like early man-made aircraft and modern fighter jets, the fruit fly employs an automatic stabilization scheme that reacts to short time-scale disturbances.

  14. Traumatic brain injury and vestibulo-ocular function: current challenges and future prospects

    PubMed Central

    Wallace, Bridgett; Lifshitz, Jonathan

    2016-01-01

    Normal function of the vestibulo-ocular reflex (VOR) coordinates eye movement with head movement, in order to provide clear vision during motion and maintain balance. VOR is generated within the semicircular canals of the inner ear to elicit compensatory eye movements, which maintain stability of images on the fovea during brief, rapid head motion, otherwise known as gaze stability. Normal VOR function is necessary in carrying out activities of daily living (eg, walking and riding in a car) and is of particular importance in higher demand activities (eg, sports-related activities). Disruption or damage in the VOR can result in symptoms such as movement-related dizziness, blurry vision, difficulty maintaining balance with head movements, and even nausea. Dizziness is one of the most common symptoms following traumatic brain injury (TBI) and is considered a risk factor for a prolonged recovery. Assessment of the vestibular system is of particular importance following TBI, in conjunction with oculomotor control, due to the intrinsic neural circuitry that exists between the ocular and vestibular systems. The purpose of this article is to review the physiology of the VOR and the visual-vestibular symptoms associated with TBI and to discuss assessment and treatment guidelines for TBI. Current challenges and future prospects will also be addressed. PMID:28539811

  15. Initial flight and simulator evaluation of a head up display for standard and noise abatement visual approaches

    NASA Technical Reports Server (NTRS)

    Bourquin, K.; Palmer, E. A.; Cooper, G.; Gerdes, R. M.

    1973-01-01

    A preliminary assessment was made of the adequacy of a simple head up display (HUD) for providing vertical guidance for flying noise abatement and standard visual approaches in a jet transport. The HUD featured gyro-stabilized approach angle scales which display the angle of declination to any point on the ground and a horizontal flight path bar which aids the pilot in his control of the aircraft flight path angle. Thirty-three standard and noise abatement approaches were flown in a Boeing 747 aircraft equipped with a head up display. The HUD was also simulated in a research simulator. The simulator was used to familiarize the pilots with the display and to determine the most suitable way to use the HUD for making high capture noise abatement approaches. Preliminary flight and simulator data are presented and problem areas that require further investigation are identified.

  16. Bicycle helmet size, adjustment, and stability.

    PubMed

    Thai, Kim T; McIntosh, Andrew S; Pang, Toh Yen

    2015-01-01

    One of the main requirements of a protective bicycle helmet is to provide and maintain adequate coverage to the head. A poorly fitting or fastened helmet may be displaced during normal use or even ejected during a crash. The aims of the current study were to identify factors that influence the size of helmet worn, identify factors that influence helmet position and adjustment, and examine the effects of helmet size worn and adjustment on helmet stability. Recreational and commuter cyclists in Sydney were surveyed to determine how helmet size and/or adjustment affected helmet stability in the real world. Anthropometric characteristics of the head were measured and, to assess helmet stability, a test analogous to the requirements of the Australian bicycle helmet standard was undertaken. Two hundred sixty-seven cyclists were recruited across all age groups and 91% wore an AS/NZS 2063-compliant helmet. The main ethnic group was Europeans (71%) followed by Asians (18%). The circumferences of the cyclists' heads matched well the circumference of the relevant ISO headform for the chosen helmet size, but the head shapes differed with respect to ISO headforms. Age and gender were associated with wearing an incorrectly sized helmet and helmet adjustment. Older males (>55 years) were most likely to wear an incorrectly sized helmet. Adult males in the 35-54 year age group were most likely to wear a correctly adjusted helmet. Using quasistatic helmet stability tests, it was found that the correctness of adjustment, rather than size, head dimensions, or shape, significantly affected helmet stability in all test directions. Bicycle helmets worn by recreational and commuter cyclists are often the wrong size and are often worn and adjusted incorrectly, especially in children and young people. Cyclists need to be encouraged to adjust their helmets correctly. Current headforms used in standards testing may not be representative of cyclists' head shapes. This may create challenges to helmet suppliers if on one hand they optimize the helmet to meet tests on ISO-related headforms while on the other seeking to offer greater range of sizes.

  17. Can a Rescuer or Simulated Patient Accurately Assess Motion During Cervical Spine Stabilization Practice Sessions?

    PubMed Central

    Shrier, Ian; Boissy, Patrick; Brière, Simon; Mellette, Jay; Fecteau, Luc; Matheson, Gordon O.; Garza, Daniel; Meeuwisse, Willem H.; Segal, Eli; Boulay, John; Steele, Russell J.

    2012-01-01

    Context: Health care providers must be prepared to manage all potential spine injuries as if they are unstable. Therefore, most sport teams devote resources to training for sideline cervical spine (C-spine) emergencies. Objective: To determine (1) how accurately rescuers and simulated patients can assess motion during C-spine stabilization practice and (2) whether providing performance feedback to rescuers influences their choice of stabilization technique. Design: Crossover study. Setting: Training studio. Patients or Other Participants: Athletic trainers, athletic therapists, and physiotherapists experienced at managing suspected C-spine injuries. Intervention(s): Twelve lead rescuers (at the patient's head) performed both the head-squeeze and trap-squeeze C-spine stabilization maneuvers during 4 test scenarios: lift-and-slide and log-roll placement on a spine board and confused patient trying to sit up or rotate the head. Main Outcome Measure(s): Interrater reliability between rescuer and simulated patient quality scores for subjective evaluation of C-spine stabilization during trials (0 = best, 10 = worst), correlation between rescuers' quality scores and objective measures of motion with inertial measurement units, and frequency of change in preference for the head-squeeze versus trap-squeeze maneuver. Results: Although the weighted κ value for interrater reliability was acceptable (0.71–0.74), scores varied by 2 points or more between rescuers and simulated patients for approximately 10% to 15% of trials. Rescuers' scores correlated with objective measures, but variability was large: 38% of trials scored as 0 or 1 by the rescuer involved more than 10° of motion in at least 1 direction. Feedback did not affect the preference for the lift-and-slide placement. For the log-roll placement, 6 of 8 participants who preferred the head squeeze at baseline preferred the trap squeeze after feedback. For the confused patient, 5 of 5 participants initially preferred the head squeeze but preferred the trap squeeze after feedback. Conclusions: Rescuers and simulated patients could not adequately assess performance during C-spine stabilization maneuvers without objective measures. Providing immediate feedback in this context is a promising tool for changing behavior preferences and improving training. PMID:22488229

  18. Head stabilization in whooping cranes

    USGS Publications Warehouse

    Kinloch, M.R.; Cronin, T.W.; Olsen, Glenn H.; Chavez-Ramirez, Felipe

    2005-01-01

    The whooping crane (Grus americana) is the tallest bird in North America, yet not much is known about its visual ecology. How these birds overcome their unusual height to identify, locate, track, and capture prey items is not well understood. There have been many studies on head and eye stabilization in large wading birds (herons and egrets), but the pattern of head movement and stabilization during foraging is unclear. Patterns of head movement and stabilization during walking were examined in whooping cranes at Patuxent Wildlife Research Center, Laurel, Maryland USA. Four whooping cranes (1 male and 3 females) were videotaped for this study. All birds were already acclimated to the presence of people and to food rewards. Whooping cranes were videotaped using both digital and Hi-8 Sony video cameras (Sony Corporation, 7-35 Kitashinagawa, 6-Chome, Shinagawa-ku, Tokyo, Japan), placed on a tripod and set at bird height in the cranes' home pens. The cranes were videotaped repeatedly, at different locations in the pens and while walking (or running) at different speeds. Rewards (meal worms, smelt, crickets and corn) were used to entice the cranes to walk across the camera's view plane. The resulting videotape was analyzed at the University of Maryland at Baltimore County. Briefly, we used a computerized reduced graphic model of a crane superimposed over each frame of analyzed tape segments by means of a custom written program (T. W. Cronin, using C++) with the ability to combine video and computer graphic input. The speed of the birds in analyzed segments ranged from 0.30 m/s to 2.64 m/s, and the proportion of time the head was stabilized ranged from 79% to 0%, respectively. The speed at which the proportion reached 0% was 1.83 m/s. The analyses suggest that the proportion of time the head is stable decreases as speed of the bird increases. In all cases, birds were able to reach their target prey with little difficulty. Thus when cranes are walking searching for food, they walk at a speed that permits them to keep their heads still and visual field immobile at least half the time.

  19. A new head phantom with realistic shape and spatially varying skull resistivity distribution.

    PubMed

    Li, Jian-Bo; Tang, Chi; Dai, Meng; Liu, Geng; Shi, Xue-Tao; Yang, Bin; Xu, Can-Hua; Fu, Feng; You, Fu-Sheng; Tang, Meng-Xing; Dong, Xiu-Zhen

    2014-02-01

    Brain electrical impedance tomography (EIT) is an emerging method for monitoring brain injuries. To effectively evaluate brain EIT systems and reconstruction algorithms, we have developed a novel head phantom that features realistic anatomy and spatially varying skull resistivity. The head phantom was created with three layers, representing scalp, skull, and brain tissues. The fabrication process entailed 3-D printing of the anatomical geometry for mold creation followed by casting to ensure high geometrical precision and accuracy of the resistivity distribution. We evaluated the accuracy and stability of the phantom. Results showed that the head phantom achieved high geometric accuracy, accurate skull resistivity values, and good stability over time and in the frequency domain. Experimental impedance reconstructions performed using the head phantom and computer simulations were found to be consistent for the same perturbation object. In conclusion, this new phantom could provide a more accurate test platform for brain EIT research.

  20. Independent walking as a major skill for the development of anticipatory postural control: evidence from adjustments to predictable perturbations.

    PubMed

    Cignetti, Fabien; Zedka, Milan; Vaugoyeau, Marianne; Assaiante, Christine

    2013-01-01

    Although there is suggestive evidence that a link exists between independent walking and the ability to establish anticipatory strategy to stabilize posture, the extent to which this skill facilitates the development of anticipatory postural control remains largely unknown. Here, we examined the role of independent walking on the infants' ability to anticipate predictable external perturbations. Non-walking infants, walking infants and adults were sitting on a platform that produced continuous rotation in the frontal plane. Surface electromyography (EMG) of neck and lower back muscles and the positions of markers located on the platform, the upper body and the head were recorded. Results from cross-correlation analysis between rectified and filtered EMGs and platform movement indicated that although muscle activation already occurred before platform movement in non-walking infants, only walking infants demonstrated an adult-like ability for anticipation. Moreover, results from further cross-correlation analysis between segmental angular displacement and platform movement together with measures of balance control at the end-points of rotation of the platform evidenced two sorts of behaviour. The adults behaved as a non-rigid non-inverted pendulum, rather stabilizing head in space, while both the walking and non-walking infants followed the platform, behaving as a rigid inverted pendulum. These results suggest that the acquisition of independent walking plays a role in the development of anticipatory postural control, likely improving the internal model for the sensorimotor control of posture. However, despite such improvement, integrating the dynamics of an external object, here the platform, within the model to maintain balance still remains challenging in infants.

  1. Linking of total elbow prosthesis during surgery; a biomechanical analysis.

    PubMed

    De Vos, Maarten J; Wagener, Marc L; Hendriks, Jan C M; Eygendaal, Denise; Verdonschot, Nico

    2013-09-01

    Presently, 2 types of elbow prostheses are used: unlinked and linked. The Latitude total elbow prosthesis allows the surgeon to decide during the implantation whether the prosthesis is placed unlinked or linked, and whether the native radial head is retained, resected, or replaced. The purpose of this study is to assess and to compare the varus and valgus laxity of the unlinked and linked version of the latitude total elbow prosthesis with: (1) the native radial head preserved, (2) the native radial head excised, and (3) the native radial head replaced by a radial head component. Biomechanical testing was performed on 14 fresh-frozen upper limb specimens. Linking the prosthesis predominantly influences the valgus laxity of the elbow. Linking the Latitude total elbow prosthesis results in increased valgus stability. In the linked version of the total elbow prosthesis, the radial head only plays a small part in both valgus and varus stability. An unlinked situation is not advised in absence of a native radial head or in case of inability to replace the radial head. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  2. Ocular Counter Rolling in Astronauts After Short- and Long-Duration Spaceflight.

    PubMed

    Reschke, Millard F; Wood, Scott J; Clément, Gilles

    2018-05-17

    Ocular counter-rolling (OCR) is a reflex generated by the activation of the gravity sensors in the inner ear that stabilizes gaze and posture during head tilt. We compared the OCR measures that were obtained in 6 astronauts before, during, and after a spaceflight lasting 4-6 days with the OCR measures obtained from 6 astronauts before and after a spaceflight lasting 4-9 months. OCR in the short-duration fliers was measured using the afterimage method during head tilt at 15°, 30°, and 45°. OCR in the long-duration fliers was measured using video-oculography during whole body tilt at 25°. A control group of 7 subjects was used to compare OCR measures during head tilt and whole body tilt. No OCR occurred during head tilt in microgravity, and the response returned to normal within 2 hours of return from short-duration spaceflight. However, the amplitude of OCR was reduced for several days after return from long-duration spaceflight. This decrease in amplitude was not accompanied by changes in the asymmetry of OCR between right and left head tilt. These results indicate that the adaptation  of otolith-driven reflexes to microgravity is a long-duration process.

  3. The effect of a single massage based on the tensegrity principle on postural stability in young women.

    PubMed

    Cieślik, Błażej; Podsiadły, Ireneusz; Kuczyński, Michał; Ostrowska, Bożena

    2017-11-06

    The aim of this study was to investigate the effects of normalized muscle tension via tensegrity-based massage on postural stability in a sample of female young adults. Nineteen females aged 21.8 ± 1.9 years were recruited presenting abnormal tension at muscles adhering to any of the following structural sites: superior iliac spine, lateral sacropelvic surface, linea aspera at 1/2 of femur length, and superior nuchal line of the occiput. Balance and postural control were assessed during bipedal stance using a force platform in multiple conditions: hard surface or soft foam surface with the head in either a neutral posture or tilted backward. Baseline and 3-min and 15-min post-treatment measures were collected while barefoot and eyes closed. Main outcomes measures included center of pressure variability, range, radius, and velocity in the anteroposterior (AP) mediolateral (ML) dimensions. In the solid surface with neutral head posture condition only AP COP measures decreased significantly (p< 0.05). In the soft surface condition, significant differences were observed in the AP and ML dimensions among most measures (p< 0.05). A single application of tensegrity-based massage positively influenced postural control in young adult females, particularly in the AP direction.

  4. The effect of neck torsion on postural stability in subjects with persistent whiplash.

    PubMed

    Yu, Li-Ju; Stokell, Raina; Treleaven, Julia

    2011-08-01

    Dysfunction of cervical receptors in neck disorders has been shown to lead to disturbances in postural stability. The neck torsion manoeuvre used in the smooth pursuit neck torsion (SPNT) test is thought to be a specific measure of neck afferent dysfunction on eye movement in those with neck pain. This study aimed to determine whether neck torsion could change balance responses in those with persistent whiplash-associated disorders (WADs). Twenty subjects with persistent WAD and 20 healthy controls aged between 18 and 50 years stood on a computerised force plate with eyes closed in comfortable stance under 5 conditions: neutral head, head turned to left and right and neck torsion to left and right. Root mean square (rms) amplitude of sway was measured in the anterior-posterior (AP) and medial-lateral (ML) directions. The whiplash group had significantly greater rms amplitude in the AP direction following neck torsion compared to the control group (p < 0.03). The results show that the neck torsion manoeuvre may lead to greater postural deficits in individuals with persistent WAD and provides further evidence of neck torsion to identify abnormal cervical afferent input, as an underlying cause of balance disturbances in WAD. Further research is warranted. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  5. Balance, mobility and gaze stability deficits remain following surgical removal of vestibular schwannoma (acoustic neuroma): an observational study.

    PubMed

    Choy, Nancy Low; Johnson, Natalie; Treleaven, Julia; Jull, Gwendolen; Panizza, Benedict; Brown-Rothwell, David

    2006-01-01

    Are there residual deficits in balance, mobility, and gaze stability after surgical removal of vestibular schwannoma? Observational study. Twelve people with a mean age of 52 years who had undergone surgical removal of vestibular schwannoma at least three months previously and had not undergone vestibular rehabilitation. Twelve age- and gender-matched healthy people who acted as controls. Handicap due to dizziness, balance, mobility, and gaze stability was measured. Handicap due to dizziness was moderate for the clinical group. They swayed significantly more than the controls in comfortable stance: firm surface eyes open and visual conflict (p < 0.05); foam surface eyes closed (p < 0.05) and visual conflict (p < 0.05); and feet together: firm surface, eyes closed (p < 0.05), foam surface, eyes open (p < 0.05) and eyes closed (p < 0.01). They displayed a higher rate of failure for timed stance and gaze stability (p < 0.05) than the controls. Step Test (p < 0.01), Tandem Walk Test (p < 0.05) and Dynamic Gait Index (p < 0.01) scores were also significantly reduced compared with controls. There was a significant correlation between handicap due to dizziness and the inability to maintain balance in single limb and tandem stance (r = 0.68, p = 0.02) and the ability to maintain gaze stability during passive head movement (r = 0.78; p = 0.02). A prospective study is required to evaluate vestibular rehabilitation to ameliorate dizziness and to improve balance, mobility, and gaze stability for this clinical group.

  6. Impact of a New York City Supportive Housing Program on Housing Stability and Preventable Health Care among Homeless Families.

    PubMed

    Lim, Sungwoo; Singh, Tejinder P; Hall, Gerod; Walters, Sarah; Gould, L Hannah

    2018-03-12

    To assess the impact of a New York City supportive housing program on housing stability and preventable emergency department (ED) visits/hospitalizations among heads of homeless families with mental and physical health conditions or substance use disorders. Multiple administrative data from New York City and New York State for 966 heads of families eligible for the program during 2007-12. We captured housing events and health care service utilization during 2 years prior to the first program eligibility date (baseline) and 2 years postbaseline. We performed sequence analysis to measure housing stability and compared housing stability and preventable ED visits and hospitalizations between program participants (treatment group) and eligible applicants not placed in the program (comparison group) via marginal structural modeling. We matched electronically collected data. Eighty-seven percent of supportive housing tenants experienced housing stability in 2 years postbaseline. Compared with unstably housed heads of families in the comparison group, those in the treatment group were 0.60 times as likely to make preventable ED visits postbaseline (95% CI = 0.38, 0.96). Supportive housing placement was associated with improved housing stability and reduced preventable health care visits among homeless families. © Health Research and Educational Trust.

  7. Effect of glenoid implant design on glenohumeral stability: an experimental study.

    PubMed

    Sins, Lauranne; Tétreault, Patrice; Petit, Yvan; Nuño, Natalia; Billuart, Fabien; Hagemeister, Nicola

    2012-10-01

    Though several glenoid implants were developed over the past years, a high rate of glenoid loosening remains. This complication is linked to the glenohumeral stability, defined as humeral head translation. In an intact shoulder, this concept is ensured by all active and passive elements, particularly the labrum. Two features of a glenoid implant can be adjusted to improve the stability, or, in other words, to decrease the translations: the first is the mismatch, defined as the difference of curvature between the prosthetic head and glenoid; the second is the shape of the glenoid component. Therefore, the objective of this study was to compare the performance of 2 glenoid components (Ceraver, Roissy, France): (1) a standard design and (2) a design named "labrum design" with a superior part simulating the anatomic labrum. An experimental device was developed to evaluate forces and kinematics. The device simulated active, dynamic and continuous abduction of an entire arm. It reproduced the Scapulo-Humeral Rhythm. The labrum design was installed first. To evaluate the effect of mismatch on the glenohumeral stability, 3 humeral heads were tested, corresponding to the ones recommended by the company. The experiment was repeated for the standard design. The results obtained show a general decrease of the prosthetic head translation with the labrum design compared to the standard design. No noticeable effect of mismatch was found. A proof of concept of the interest of the artificial labrum was provided since it improved the glenohumeral stability. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. The novel support structure design of high stability for space borne primary reflector

    NASA Astrophysics Data System (ADS)

    Yu, Fei; Ding, Lin; Tan, Ting; Pei, Jing-yang.; Zhao, Xue-min; Bai, Shao-jun

    2018-01-01

    The novel support structure design of high stability for space borne primary mirror is presented. The structure is supported by a ball head support rod, for statically determinate support of reflector. The ball head assembly includes the supporting rod, nesting, bushing and other important parts. The liner bushing of the resistant material is used to fit for ball head approximated with the reflector material, and then the bad impact of thermal mismatch could be minimized to minimum. In order to ensure that the structure of the support will not be damaged, the glue spots for limitation is added around the reflector, for position stability of reflector. Through analysis and calculation, it can be seen that the novel support structure would not transfer the external stresses to the reflector, and the external stresses usually result from thermal mismatch and assembly misalignment. The novel method is useful for solving the problem of the bad influence form thermal stress and assembly force. In this paper, the supporting structure is introduced and analyzed in detail. The simulation results show that the ball head support reflector works more stably.

  9. Control of Smc Coiled Coil Architecture by the ATPase Heads Facilitates Targeting to Chromosomal ParB/parS and Release onto Flanking DNA

    PubMed Central

    Minnen, Anita; Bürmann, Frank; Wilhelm, Larissa; Anchimiuk, Anna; Diebold-Durand, Marie-Laure; Gruber, Stephan

    2016-01-01

    Summary Smc/ScpAB promotes chromosome segregation in prokaryotes, presumably by compacting and resolving nascent sister chromosomes. The underlying mechanisms, however, are poorly understood. Here, we investigate the role of the Smc ATPase activity in the recruitment of Smc/ScpAB to the Bacillus subtilis chromosome. We demonstrate that targeting of Smc/ScpAB to ParB/parS loading sites is strictly dependent on engagement of Smc head domains and relies on an open organization of the Smc coiled coils. We find that dimerization of the Smc hinge domain stabilizes closed Smc rods and hinders head engagement as well as chromosomal targeting. Conversely, the ScpAB sub-complex promotes head engagement and Smc rod opening and thereby facilitates recruitment of Smc to parS sites. Upon ATP hydrolysis, Smc/ScpAB is released from loading sites and relocates within the chromosome—presumably through translocation along DNA double helices. Our findings define an intermediate state in the process of chromosome organization by Smc. PMID:26904953

  10. Integration of visual and non-visual self-motion cues during voluntary head movements in the human brain.

    PubMed

    Schindler, Andreas; Bartels, Andreas

    2018-05-15

    Our phenomenological experience of the stable world is maintained by continuous integration of visual self-motion with extra-retinal signals. However, due to conventional constraints of fMRI acquisition in humans, neural responses to visuo-vestibular integration have only been studied using artificial stimuli, in the absence of voluntary head-motion. We here circumvented these limitations and let participants to move their heads during scanning. The slow dynamics of the BOLD signal allowed us to acquire neural signal related to head motion after the observer's head was stabilized by inflatable aircushions. Visual stimuli were presented on head-fixed display goggles and updated in real time as a function of head-motion that was tracked using an external camera. Two conditions simulated forward translation of the participant. During physical head rotation, the congruent condition simulated a stable world, whereas the incongruent condition added arbitrary lateral motion. Importantly, both conditions were precisely matched in visual properties and head-rotation. By comparing congruent with incongruent conditions we found evidence consistent with the multi-modal integration of visual cues with head motion into a coherent "stable world" percept in the parietal operculum and in an anterior part of parieto-insular cortex (aPIC). In the visual motion network, human regions MST, a dorsal part of VIP, the cingulate sulcus visual area (CSv) and a region in precuneus (Pc) showed differential responses to the same contrast. The results demonstrate for the first time neural multimodal interactions between precisely matched congruent versus incongruent visual and non-visual cues during physical head-movement in the human brain. The methodological approach opens the path to a new class of fMRI studies with unprecedented temporal and spatial control over visuo-vestibular stimulation. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Red cell membrane skeleton: structure-function relationships.

    PubMed

    Palek, J; Liu, S C

    1980-01-01

    This papaer reviews our present understanding of ultrastructure, organization, and functional characteristics of the erythrocyte membrane cytoskeleton. This two-dimensional fibrillar network of submembrane proteins can be visualized after extraction of lipids and integral membrane proteins by Triton X-100. Current data suggest that the major structural components of the cytoskeleton are heterodimers of double-stranded spectrin that form tetramers by head-to-head associations. The tetramers may be connected into a fibrillar meshwork by oligomers of actin. The control of membrane integrity by this network is illustrated by examples of two hemolyotic anemias characterized by marked membrane instability and vesiculation: 1) hereditary spherocytic anemia of the house mouse associated with spectrin deficiency and 2) hereditary pyropoikilocytosis, a hemolytic anemia in man characterized by thermal instability of the membrane and the presence of abnormal spectrin, which exhibits an increased propensity to thermal denaturation. Stabilization of the cytoskeletal network by covalent cross-links between the nearest cytoskeletal and integral membrane proteins results in a decrease of membrane deformability and a fixation of erythrocytes in their abnormal shape. Such cross-linkings include: 1) transamidative cross-links produced by introduction of Ca2+ (>0.5 mM) into fresh erythrocytes, and 2) intermolecular disulfide couplings, which are formed after extensive oxidation of fresh erythrocytes or after mild oxidation of ATP-depleted, but not fresh, erythrocytes. The significance of these cross-links in stabilization of shape of abnormal erythrocytes such as schistocytes remains to be determined. We conclude that spectrin and actin form a fibrillar submembrane network that plays an important role in control of membrane integrity, erythrocyte deformability, and stabilization of cells in abnormal shapes.

  12. Coordinated three-dimensional motion of the head and torso by dynamic neural networks.

    PubMed

    Kim, J; Hemami, H

    1998-01-01

    The problem of trajectory tracking control of a three dimensional (3D) model of the human upper torso and head is considered. The torso and the head are modeled as two rigid bodies connected at one point, and the Newton-Euler method is used to derive the nonlinear differential equations that govern the motion of the system. The two-link system is driven by six pairs of muscle like actuators that possess physiologically inspired alpha like and gamma like inputs, and spindle like and Golgi tendon organ like outputs. These outputs are utilized as reflex feedback for stability and stiffness control, in a long loop feedback for the purpose of estimating the state of the system (somesthesis), and as part of the input to the controller. Ideal delays of different duration are included in the feedforward and feedback paths of the system to emulate such delays encountered in physiological systems. Dynamical neural networks are trained to learn effective control of the desired maneuvers of the system. The feasibility of the controller is demonstrated by computer simulation of the successful execution of the desired maneuvers. This work demonstrates the capabilities of neural circuits in controlling highly nonlinear systems with multidelays in their feedforward and feedback paths. The ultimate long range goal of this research is toward understanding the working of the central nervous system in controlling movement. It is an interdisciplinary effort relying on mechanics, biomechanics, neuroscience, system theory, physiology and anatomy, and its short range relevance to rehabilitation must be noted.

  13. Neuromuscular Impairments Are Associated With Impaired Head and Trunk Stability During Gait in Parkinson Fallers.

    PubMed

    Cole, Michael H; Naughton, Geraldine A; Silburn, Peter A

    2017-01-01

    Background The trunk plays a critical role in attenuating movement-related forces that threaten to challenge the body's postural control system. For people with Parkinson's disease (PD), disease progression often leads to dopamine-resistant axial symptoms, which impair trunk control and increase falls risk. Objective This prospective study aimed to evaluate the relationship between impaired trunk muscle function, segmental coordination, and future falls in people with PD. Methods Seventy-nine PD patients and 82 age-matched controls completed clinical assessments and questionnaires to establish their medical history, symptom severity, balance confidence, and falls history. Gait characteristics and trunk muscle activity were assessed using 3-dimensional motion analysis and surface electromyography. The incidence, cause, and consequence of any falls experienced over the next 12 months were recorded and indicated that 48 PD and 29 control participants fell at least once during this time. Results PD fallers had greater peak and baseline lumbar multifidus (LMF) and thoracic erector spinae (TES) activations than control fallers and nonfallers. Analysis of covariance indicated that the higher LMF activity was attributable to the stooped posture adopted by PD fallers, but TES activity was independent of medication use, symptom severity, and trunk orientation. Furthermore, greater LMF and TES baseline activity contributed to increasing lateral head, trunk, and pelvis movements in PD fallers but not nonfallers or controls. Conclusions The results provide evidence of neuromuscular deficits for PD fallers that are independent of medications, symptom severity, and posture and contribute to impaired head, trunk, and pelvis control associated with falls in this population. © The Author(s) 2016.

  14. A biomechanical model of the craniomandibular complex and cervical spine based on the inverted pendulum.

    PubMed

    Gillies, G T; Broaddus, W C; Stenger, J M; Taylor, A G

    1998-01-01

    The head and neck constitute an inverted pendulum that is stabilized during consciousness by neuromuscular restoring forces. An analysis of the dynamics of this inverted pendulum suggests that the mechanics of the mandible and temporomandibular joint might couple into those of the pendulum's stabilization process. In this article, physical principles of the inverted pendulum model as these apply to the head and neck are explored, and the authors describe implications of mandibular mechanics for the forces acting on the head and neck at equilibrium. This novel application of the inverted pendulum model predicts that alteration or pathology of temporomandibular mechanics would lead to perturbations of the normal forces acting in the head and neck. Under certain circumstances, these perturbations could be expected to contribute to symptoms and result in additional or accelerated degenerative effects.

  15. Mechanisms of Sensorimotor Adaptation to Centrifugation

    NASA Technical Reports Server (NTRS)

    Paloski, W. H.; Wood, S. J.; Kaufman, G. D.

    1999-01-01

    We postulate that centripetal acceleration induced by centrifugation can be used as an inflight sensorimotor countermeasure to retain and/or promote appropriate crewmember responses to sustained changes in gravito-inertial force conditions. Active voluntary motion is required to promote vestibular system conditioning, and both visual and graviceptor sensory feedback are critical for evaluating internal representations of spatial orientation. The goal of our investigation is to use centrifugation to develop an analog to the conflicting visual/gravito-inertial force environment experienced during space flight, and to use voluntary head movements during centrifugation to study mechanisms of adaptation to altered gravity environments. We address the following two hypotheses: (1) Discordant canal-otolith feedback during head movements in a hypergravity tilted environment will cause a reorganization of the spatial processing required for multisensory integration and motor control, resulting in decreased postural stability upon return to normal gravity environment. (2) Adaptation to this "gravito-inertial tilt distortion" will result in a negative after-effect, and readaptation will be expressed by return of postural stability to baseline conditions. During the third year of our grant we concentrated on examining changes in balance control following 90-180 min of centrifugation at 1.4 9. We also began a control study in which we exposed subjects to 90 min of sustained roll tilt in a static (non-rotating) chair. This allowed us to examine adaptation to roll tilt without the hypergravity induced by centrifugation. To these ends, we addressed the question: Is gravity an internal calibration reference for postural control? The remainder of this report is limited to presenting preliminary findings from this study.

  16. Acetylcholine contributes to the integration of self-movement cues in head direction cells.

    PubMed

    Yoder, Ryan M; Chan, Jeremy H M; Taube, Jeffrey S

    2017-08-01

    Acetylcholine contributes to accurate performance on some navigational tasks, but details of its contribution to the underlying brain signals are not fully understood. The medial septal area provides widespread cholinergic input to various brain regions, but selective damage to medial septal cholinergic neurons generally has little effect on landmark-based navigation, or the underlying neural representations of location and directional heading in visual environments. In contrast, the loss of medial septal cholinergic neurons disrupts navigation based on path integration, but no studies have tested whether these path integration deficits are associated with disrupted head direction (HD) cell activity. Therefore, we evaluated HD cell responses to visual cue rotations in a familiar arena, and during navigation between familiar and novel arenas, after muscarinic receptor blockade with systemic atropine. Atropine treatment reduced the peak firing rate of HD cells, but failed to significantly affect other HD cell firing properties. Atropine also failed to significantly disrupt the dominant landmark control of the HD signal, even though we used a procedure that challenged this landmark control. In contrast, atropine disrupted HD cell stability during navigation between familiar and novel arenas, where path integration normally maintains a consistent HD cell signal across arenas. These results suggest that acetylcholine contributes to path integration, in part, by facilitating the use of idiothetic cues to maintain a consistent representation of directional heading. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Catalytic Properties of Unsupported Palladium Nanoparticle Surfaces Capped with Small Organic Ligands

    PubMed Central

    Gavia, Diego J.

    2015-01-01

    This Minireview summarizes a variety of intriguing catalytic studies accomplished by employing unsupported, either solubilized or freely mobilized, and small organic ligand-capped palladium nanoparticles as catalysts. Small organic ligands are gaining more attention as nanoparticle stabilizers and alternates to larger organic supports, such as polymers and dendrimers, owing to their tremendous potential for a well-defined system with spatial control in surrounding environments of reactive surfaces. The nanoparticle catalysts are grouped depending on the type of surface stabilizers with reactive head groups, which include thiolate, phosphine, amine, and alkyl azide. Applications for the reactions such as hydrogenation, alkene isomerization, oxidation, and carbon-carbon cross coupling reactions are extensively discussed. The systems defined as “ligandless” Pd nanoparticle catalysts and solvent (e.g. ionic liquid)-stabilized Pd nanoparticle catalysts are not discussed in this review. PMID:25937846

  18. Morphometric changes in Yellow-headed Blackbirds during summer in central North Dakota

    USGS Publications Warehouse

    Twedt, D.J.; Linz, G.M.

    2002-01-01

    Temporal stability of morphometric measurements is desirable when using avian morphology as a predictor of geographic origin. Therefore, to assess their temporal stability, we examined changes in morphology of Yellow-headed Blackbirds (Xanthocephalus xanthocephalus) from central North Dakota during summer. Measurements differed among age classes and between sexes. As expected, due to growth and maturation, measurements on hatching-year birds increased over summer. Measurements of adult plumage fluctuated with prebasic molt and exhibited age-specific discontinuities. Body mass of adult birds increased over summer, whereas both culmen length and skull length decreased. Only body length and length of internal skeletal elements were temporally stable in adult Yellow-headed Blackbirds.

  19. Randomized Controlled Study of a Remote Flipped Classroom Neuro-otology Curriculum.

    PubMed

    Carrick, Frederick Robert; Abdulrahman, Mahera; Hankir, Ahmed; Zayaruzny, Maksim; Najem, Kinda; Lungchukiet, Palita; Edwards, Roger A

    2017-01-01

    Medical Education can be delivered in the traditional classroom or via novel technology including an online classroom. To test the hypothesis that learning in an online classroom would result in similar outcomes as learning in the traditional classroom when using a flipped classroom pedagogy. Randomized controlled trial. A total of 274 subjects enrolled in a Neuro-otology training program for non-Neuro-otologists of 25 h held over a 3-day period. Subjects were randomized into a "control" group attending a traditional classroom and a "trial" group of equal numbers participating in an online synchronous Internet streaming classroom using the Adobe Connect e-learning platform. Subjects were randomized into a "control" group attending a traditional classroom and a "treatment" group of equal numbers participating in an online synchronous Internet streaming classroom. Pre- and post-multiple choice examinations of VOR, Movement, Head Turns, Head Tremor, Neurodegeneration, Inferior Olivary Complex, Collateral Projections, Eye Movement Training, Visual Saccades, Head Saccades, Visual Impairment, Walking Speed, Neuroprotection, Autophagy, Hyperkinetic Movement, Eye and Head Stability, Oscilllatory Head Movements, Gaze Stability, Leaky Neural Integrator, Cervical Dystonia, INC and Head Tilts, Visual Pursuits, Optokinetic Stimulation, and Vestibular Rehabilitation. All candidates took a pretest examination of the subject material. The 2-9 h and 1-8 h sessions over three consecutive days were given live in the classroom and synchronously in the online classroom using the Adobe Connect e-learning platform. Subjects randomized to the online classroom attended the lectures in a location of their choice and viewed the sessions live on the Internet. A posttest examination was given to all candidates after completion of the course. Two sample unpaired t tests with equal variances were calculated for all pretests and posttests for all groups including gender differences. All 274 subjects demonstrated statistically significant learning by comparison of their pre- and posttest scores. There were no statistically significant differences in the test scores between the two groups of 137 subjects each (0.8%, 95% CI 85.45917-86.67952; P  = 0.9195). A total of 101 males in the traditional classroom arm had statistically significant lower scores than 72 females (0.8%, 95% CI 84.65716-86.53096; P  = 0.0377) but not in the online arm (0.8%, 95% CI 85.46172-87.23135; P  = 0.2176) with a moderate effect size (Cohen's d  = -0.407). The use of a synchronous online classroom in neuro-otology clinical training has demonstrated similar outcomes to the traditional classroom. The online classroom is a low cost and effective complement to medical specialty training in Neuro-Otology. The significant difference in outcomes between males and females who attended the traditional classroom suggests that women may do better than males in this learning environment, although the effect size is moderate. Clinicaltrials.gov, identifier NCT03079349.

  20. Allicat magnetoresistive head design and performance

    NASA Astrophysics Data System (ADS)

    Hannon, David; Krounbi, Mohamed; Christner, Jodie

    1994-03-01

    The general design features of the magnetoresistive (MR) merged head are described and compared to the earlier MR piggy-back head called Corsair. Examples of static, magnetic, and error rate testing are given. Dual track profiles show the read-narrow feature of the MR head. Stability of the signal with write disturbance shows the effectiveness of the hard-bias longitudinal biasing. Error rate versus off-track position indicates the robustness of the file design.

  1. The effect of head-down tilt and water immersion on intracranial pressure in nonhuman primates

    NASA Technical Reports Server (NTRS)

    Keil, Lanny C.; Mckeever, Kenneth H.; Skidmore, Michael G.; Hines, John; Severs, Walter B.

    1992-01-01

    Intracranial pressure (ICP) is investigated in primates during and after -6-deg head-down tilt (HDT) and immersion in water to examine the effects of the headward fluid shift related to spaceflight. Following the HDT the primates are subjected to head-out thermoneutral water immersion, and the ICP is subsequently measured. ICP is found to increase from 3.8 +/- 1.1 to 5.3 +/- 1.3 mm Hg during the horizontal control period. ICP stabilizes at -6.3 +/- 1.3 mm Hg and then increases to -2.2 +/- 1.9 mm Hg during partial immersion, and ICP subsequently returns to preimmersion levels after immersion. These data indicate that exposure to HDT or water immersion lead to an early sharp increase in ICP, and water immersion alone leads to higher ICP levels. A significant conclusion of the work is that the ICP did not approach pathological levels, and this finding is relevant to human spaceflight research.

  2. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  3. Cooperative Binding of Cyclodextrin Dimers to Isoflavone Analogues Elucidated by Free Energy Calculations.

    PubMed

    Zhang, Haiyang; Tan, Tianwei; Hetényi, Csaba; Lv, Yongqin; van der Spoel, David

    2014-04-03

    Dimerization of cyclodextrin (CD) molecules is an elementary step in the construction of CD-based nanostructured materials. Cooperative binding of CD cavities to guest molecules facilitates the dimerization process and, consequently, the overall stability and assembly of CD nanostructures. In the present study, all three dimerization modes (head-to-head, head-to-tail, and tail-to-tail) of β-CD molecules and their binding to three isoflavone drug analogues (puerarin, daidzin, and daidzein) were investigated in explicit water surrounding using molecular dynamics simulations. Total and individual contributions from the binding partners and solvent environment to the thermodynamics of these binding reactions are quantified in detail using free energy calculations. Cooperative drug binding to two CD cavities gives an enhanced binding strength for daidzin and daidzein, whereas for puerarin no obvious enhancement is observed. Head-to-head dimerization yields the most stable complexes for inclusion of the tested isoflavones (templates) and may be a promising building block for construction of template-stabilized CD nanostructures. Compared to the case of CD monomers, the desolvation of CD dimers and entropy changes upon complexation prove to be influential factors of cooperative binding. Our results shed light on key points of the design of CD-based supramolecular assemblies. We also show that structure-based calculation of binding thermodynamics can quantify stabilization caused by cooperative effects in building blocks of nanostructured materials.

  4. Motion‐related artifacts in structural brain images revealed with independent estimates of in‐scanner head motion

    PubMed Central

    Savalia, Neil K.; Agres, Phillip F.; Chan, Micaela Y.; Feczko, Eric J.; Kennedy, Kristen M.

    2016-01-01

    Abstract Motion‐contaminated T1‐weighted (T1w) magnetic resonance imaging (MRI) results in misestimates of brain structure. Because conventional T1w scans are not collected with direct measures of head motion, a practical alternative is needed to identify potential motion‐induced bias in measures of brain anatomy. Head movements during functional MRI (fMRI) scanning of 266 healthy adults (20–89 years) were analyzed to reveal stable features of in‐scanner head motion. The magnitude of head motion increased with age and exhibited within‐participant stability across different fMRI scans. fMRI head motion was then related to measurements of both quality control (QC) and brain anatomy derived from a T1w structural image from the same scan session. A procedure was adopted to “flag” individuals exhibiting excessive head movement during fMRI or poor T1w quality rating. The flagging procedure reliably reduced the influence of head motion on estimates of gray matter thickness across the cortical surface. Moreover, T1w images from flagged participants exhibited reduced estimates of gray matter thickness and volume in comparison to age‐ and gender‐matched samples, resulting in inflated effect sizes in the relationships between regional anatomical measures and age. Gray matter thickness differences were noted in numerous regions previously reported to undergo prominent atrophy with age. Recommendations are provided for mitigating this potential confound, and highlight how the procedure may lead to more accurate measurement and comparison of anatomical features. Hum Brain Mapp 38:472–492, 2017. © 2016 Wiley Periodicals, Inc. PMID:27634551

  5. AQUILA Remotely Piloted Vehicle System Technology Demonstrator (RPV-STD) Program. Volume I. System Description and Capabilities

    DTIC Science & Technology

    1979-04-01

    tools, simplification of equipment interfaces involved in manual operations to provide simple system preparation, closing flight control inner loops ...alti- tude, and heading rate. The closed loops operate in three primary modes: cruise, dead reckoning, and approach. The aircraft is stabilized by...onboard closed loops , so the operator is not required to maintain hands-on operation to keep it in the air. The operator is able to command airspeed

  6. Symptoms elicited in persons with vestibular dysfunction while performing gaze movements in optic flow environments

    PubMed Central

    Whitney, Susan L.; Sparto, Patrick J.; Cook, James R.; Redfern, Mark S.; Furman, Joseph M.

    2016-01-01

    Introduction People with vestibular disorders often experience space and motion discomfort when exposed to moving or highly textured visual scenes. The purpose of this study was to measure the type and severity of symptoms in people with vestibular dysfunction during coordinated head and eye movements in optic flow environments. Methods Seven subjects with vestibular disorders and 25 controls viewed four different full-field optic flow environments on six different visits. The optic flow environments consisted of textures with various contrasts and spatial frequencies. Subjects performed 8 gaze movement tasks, including eye saccades, gaze saccades, and gaze stabilization tasks. Subjects reported symptoms using Subjective Units of Discomfort (SUD) and the Simulator Sickness Questionnaire (SSQ). Self-reported dizziness handicap and space and motion discomfort were also measured. Results/ Conclusion Subjects with vestibular disorders had greater discomfort and experienced greater oculomotor and disorientation symptoms. The magnitude of the symptoms increased during each visit, but did not depend on the optic flow condition. Subjects who reported greater dizziness handicap and space motion discomfort had greater severity of symptoms during the experiment. Symptoms of fatigue, difficulty focusing, and dizziness during the experiment were evident. Compared with controls, subjects with vestibular disorders had less head movement during the gaze saccade tasks. Overall, performance of gaze pursuit and gaze stabilization tasks in moving visual environments elicited greater symptoms in subjects with vestibular disorders compared with healthy subjects. PMID:23549055

  7. Understanding the Effects of Spaceflight on Head-trunk Coordination During Walking and Obstacle Avoidance

    NASA Technical Reports Server (NTRS)

    Madansingh, S.; Bloomberg, J. J.

    2014-01-01

    Prolonged exposure to spaceflight conditions results in a battery of physiological changes, some of which contribute to sensorimotor and neurovestibular deficits. Upon return to Earth, functional performance changes are tested using the Functional Task Test (FTT), which includes an obstacle course to observe post-flight balance and postural stability, specifically during turning. The goal of this study was to quantify changes in movement strategies during turning events by observing the latency between head-and-trunk coordinated movements. It was hypothesized that subjects experiencing neurovestibular adaptations would exhibit head-to-trunk locking ('en bloc' movement) during turning, exhibited by a decrease in latency between head and trunk movement. FTT data samples were collected from 13 ISS astronauts and 26 male 70-day head down tilt bed rest subjects, including bed rest controls (10 BRC) and bed rest exercisers (16 BRE). Samples were analyzed three times pre-exposure, immediately post-exposure (0 or 1 day post) and 2-to-3 times during recovery from the unloading environment. Two 3D inertial measurements units (XSens MTx) were attached to subjects, one on the head and one on the upper back. This study focused primarily on the yaw movements about the subject's center of rotation. Time differences (latency) between head and trunk movement were averaged across a slalom obstacle portion, consisting of three turns (approximately three 60° turns). All participants were grouped as 'decreaser' or 'increaser,' relating to their change in head-to-trunk movement latency between pre- and post- environmental adaptation measures. Space flight unloading (ISS) showed a bimodal response between the 'increaser' and 'decreaser' group, while both bed rest control (BRC) and bed rest exercise (BRE) populations showed increased preference towards a 'decreaser' categorization, displaying greater head-trunk locking. It is clear that changes in movement strategies are adopted during exposure to an unloading environment. These results further the understanding of vestibular-somatosensory convergence and support the use of bed rest as an exclusionary model to better understand sensorimotor changes in space flight.

  8. Effects of repeated snowboard exercise in virtual reality with time lags of visual scene behind body rotation on head stability and subjective slalom run performance in healthy young subjects.

    PubMed

    Wada, Yoshiro; Nishiike, Suetaka; Kitahara, Tadashi; Yamanaka, Toshiaki; Imai, Takao; Ito, Taeko; Sato, Go; Matsuda, Kazunori; Kitamura, Yoshiaki; Takeda, Noriaki

    2016-11-01

    After repeated snowboard exercises in the virtual reality (VR) world with increasing time lags in trials 3-8, it is suggested that the adaptation to repeated visual-vestibulosomatosensory conflict in the VR world improved dynamic posture control and motor performance in the real world without the development of motion sickness. The VR technology was used and the effects of repeated snowboard exercise examined in the VR world with time lags between visual scene and body rotation on the head stability and slalom run performance during exercise in healthy subjects. Forty-two healthy young subjects participated in the study. After trials 1 and 2 of snowboard exercise in the VR world without time lag, trials 3-8 were conducted with 0.1, 0.2, 0.3, 0.4, 0.5, and 0.6 s time lags of the visual scene that the computer creates behind board rotation, respectively. Finally, trial 9 was conducted without time lag. Head linear accelerations and subjective slalom run performance were evaluated. The standard deviations of head linear accelerations in inter-aural direction were significantly increased in trial 8, with a time lag of 0.6 s, but significantly decreased in trial 9 without a time lag, compared with those in trial 2 without a time lag. The subjective scores of slalom run performance were significantly decreased in trial 8, with a time lag of 0.6 s, but significantly increased in trial 9 without a time lag, compared with those in trial 2 without a time lag. Motion sickness was not induced in any subjects.

  9. Motion parallax in immersive cylindrical display systems

    NASA Astrophysics Data System (ADS)

    Filliard, N.; Reymond, G.; Kemeny, A.; Berthoz, A.

    2012-03-01

    Motion parallax is a crucial visual cue produced by translations of the observer for the perception of depth and selfmotion. Therefore, tracking the observer viewpoint has become inevitable in immersive virtual (VR) reality systems (cylindrical screens, CAVE, head mounted displays) used e.g. in automotive industry (style reviews, architecture design, ergonomics studies) or in scientific studies of visual perception. The perception of a stable and rigid world requires that this visual cue be coherent with other extra-retinal (e.g. vestibular, kinesthetic) cues signaling ego-motion. Although world stability is never questioned in real world, rendering head coupled viewpoint in VR can lead to the perception of an illusory perception of unstable environments, unless a non-unity scale factor is applied on recorded head movements. Besides, cylindrical screens are usually used with static observers due to image distortions when rendering image for viewpoints different from a sweet spot. We developed a technique to compensate in real-time these non-linear visual distortions, in an industrial VR setup, based on a cylindrical screen projection system. Additionally, to evaluate the amount of discrepancies tolerated without perceptual distortions between visual and extraretinal cues, a "motion parallax gain" between the velocity of the observer's head and that of the virtual camera was introduced in this system. The influence of this artificial gain was measured on the gait stability of free-standing participants. Results indicate that, below unity, gains significantly alter postural control. Conversely, the influence of higher gains remains limited, suggesting a certain tolerance of observers to these conditions. Parallax gain amplification is therefore proposed as a possible solution to provide a wider exploration of space to users of immersive virtual reality systems.

  10. Individual differences in the ability to identify, select and use appropriate frames of reference for perceptuo-motor control.

    PubMed

    Isableu, B; Ohlmann, T; Cremieux, J; Vuillerme, N; Amblard, B; Gresty, M A

    2010-09-01

    The causes of the interindividual differences (IDs) in how we perceive and control spatial orientation are poorly understood. Here, we propose that IDs partly reflect preferred modes of spatial referencing and that these preferences or "styles" are maintained from the level of spatial perception to that of motor control. Two groups of experimental subjects, one with high visual field dependency (FD) and one with marked visual field independency (FI) were identified by the Rod and Frame Test, which identifies relative dependency on a visual frame of reference (VFoR). FD and FI subjects were tasked with standing still in conditions of increasing postural difficulty while visual cues of self-orientation (a visual frame tilted in roll) and self-motion (in stroboscopic illumination) were varied and in darkness to assess visual dependency. Postural stability, overall body orientation and modes of segmental stabilization relative to either external (space) or egocentric (adjacent segments) frames of reference in the roll plane were analysed. We hypothesized that a moderate challenge to balance should enhance subjects' reliance on VFoR, particularly in FD subjects, whereas a substantial challenge should constrain subjects to use a somatic-vestibular based FoR to prevent falling in which case IDs would vanish. The results showed that with increasing difficulty, FD subjects became more unstable and more disoriented shown by larger effects of the tilted visual frame on posture. Furthermore, their preference to coalign body/VFoR coordinate systems lead to greater fixation of the head-trunk articulation and stabilization of the hip in space, whereas the head and trunk remained more stabilized in space with the hip fixed on the leg in FI subjects. These results show that FD subjects have difficulties at identifying and/or adopting a more appropriate FoR based on proprioceptive and vestibular cues to regulate the coalignment of posturo/exocentric FoRs. The FI subjects' resistance in the face of altered VFoR and balance challenge resides in their greater ability to coordinate movement by coaligning body axes with more appropriate FoRs (provided by proprioceptive and vestibular co-variance). Copyright (c) 2010 IBRO. Published by Elsevier Ltd. All rights reserved.

  11. Vertical Descent and Landing Tests of a 0.13-Scale Model of the Convair XFY-1 Vertically Rising Airplane in Still Air, TED No. NACA DE 368

    NASA Technical Reports Server (NTRS)

    Smith, Charlee C., Jr.; Lovell, Powell M., Jr.

    1954-01-01

    An investigation is being conducted to determine the dynamic stability and control characteristics of a 0.13-scale flying model of Convair XFY-1 vertically rising airplane. This paper presents the results of flight and force tests to determine the stability and control characteristics of the model in vertical descent and landings in still air. The tests indicated that landings, including vertical descent from altitudes representing up to 400 feet for the full-scale airplane and at rates of descent up to 15 or 20 feet per second (full scale), can be performed satisfactorily. Sustained vertical descent in still air probably will be more difficult to perform because of large random trim changes that become greater as the descent velocity is increased. A slight steady head wind or cross wind might be sufficient to eliminate the random trim changes.

  12. Hubble Space Telescope Reduced-Gyro Control Law Design, Implementation, and On-Orbit Performance

    NASA Technical Reports Server (NTRS)

    Clapp, Brian R.; Ramsey, Patrick R.; Wirzburger, John H.; Smith, Daniel C.; VanArsadall, John C.

    2008-01-01

    Following gyro failures in April 2001 and April 2003, HST Pointing Control System engineers designed reduced-gyro control laws to extend the spacecraft science mission. The Two-Gyro Science (TGS) and One-Gyro Science (OGS) control laws were designed and implemented using magnetometers, star trackers, and Fine Guidance Sensors in succession to control vehicle rate about the missing gyro axes. Both TGS and OGS have demonstrated on-orbit pointing stability of 7 milli-arcseconds or less, which depends upon the guide star magnitude used by the Fine Guidance Sensor. This paper describes the design, implementation, and on-orbit performance of the TGS and OGS control law fine-pointing modes using Fixed Head Star Trackers and Fine Guidance Sensors, after successfully achieving coarse-pointing control using magnetometers.

  13. Visualization of 3D elbow kinematics using reconstructed bony surfaces

    NASA Astrophysics Data System (ADS)

    Lalone, Emily A.; McDonald, Colin P.; Ferreira, Louis M.; Peters, Terry M.; King, Graham J. W.; Johnson, James A.

    2010-02-01

    An approach for direct visualization of continuous three-dimensional elbow kinematics using reconstructed surfaces has been developed. Simulation of valgus motion was achieved in five cadaveric specimens using an upper arm simulator. Direct visualization of the motion of the ulna and humerus at the ulnohumeral joint was obtained using a contact based registration technique. Employing fiducial markers, the rendered humerus and ulna were positioned according to the simulated motion. The specific aim of this study was to investigate the effect of radial head arthroplasty on restoring elbow joint stability after radial head excision. The position of the ulna and humerus was visualized for the intact elbow and following radial head excision and replacement. Visualization of the registered humerus/ulna indicated an increase in valgus angulation of the ulna with respect to the humerus after radial head excision. This increase in valgus angulation was restored to that of an elbow with a native radial head following radial head arthroplasty. These findings were consistent with previous studies investigating elbow joint stability following radial head excision and arthroplasty. The current technique was able to visualize a change in ulnar position in a single DoF. Using this approach, the coupled motion of ulna undergoing motion in all 6 degrees-of-freedom can also be visualized.

  14. Biomechanical benefits of anterior offsetting of humeral head component in posteriorly unstable total shoulder arthroplasty: A cadaveric study.

    PubMed

    Kim, Hyun-Min Mike; Chacon, Alexander C; Andrews, Seth H; Roush, Evan P; Cho, Edward; Conaway, William K; Kunselman, Allen R; Lewis, Gregory S

    2016-04-01

    Restoration of joint stability during total shoulder arthroplasty can be challenging in the face of severe glenoid retroversion. A novel technique of humeral head component anterior-offsetting has been proposed to address posterior instability. We evaluated the biomechanical benefits of this technique in cadaveric specimens. Total shoulder arthroplasty was performed in 14 cadaveric shoulders from 7 donors. Complementary shoulders were assigned to either 10° or 20° glenoid retroversion, with retroversion created by eccentric reaming. Two humeral head component offset positions were tested in each specimen: The anatomic (posterior) and anterior (reverse). With loads applied to the rotator cuff and deltoid, joint contact pressures and the force and energy required for posterior humeral head translation were measured. The force and energy required to displace the humeral head posteriorly increased significantly with the anterior offset position compared to the anatomic offset position. The joint contact pressures were significantly shifted anteriorly, and the joint contact area significantly increased with the anterior offset position. Anterior offsetting of the humeral head component increased the resistance to posterior humeral head translation, shifted joint contact pressures anteriorly, and increased joint contact area, thus, potentially increasing the joint stability in total shoulder arthroplasty with simulated glenoid retroversion. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Competitive Dynamics in MSTd: A Mechanism for Robust Heading Perception Based on Optic Flow

    PubMed Central

    Layton, Oliver W.; Fajen, Brett R.

    2016-01-01

    Human heading perception based on optic flow is not only accurate, it is also remarkably robust and stable. These qualities are especially apparent when observers move through environments containing other moving objects, which introduce optic flow that is inconsistent with observer self-motion and therefore uninformative about heading direction. Moving objects may also occupy large portions of the visual field and occlude regions of the background optic flow that are most informative about heading perception. The fact that heading perception is biased by no more than a few degrees under such conditions attests to the robustness of the visual system and warrants further investigation. The aim of the present study was to investigate whether recurrent, competitive dynamics among MSTd neurons that serve to reduce uncertainty about heading over time offer a plausible mechanism for capturing the robustness of human heading perception. Simulations of existing heading models that do not contain competitive dynamics yield heading estimates that are far more erratic and unstable than human judgments. We present a dynamical model of primate visual areas V1, MT, and MSTd based on that of Layton, Mingolla, and Browning that is similar to the other models, except that the model includes recurrent interactions among model MSTd neurons. Competitive dynamics stabilize the model’s heading estimate over time, even when a moving object crosses the future path. Soft winner-take-all dynamics enhance units that code a heading direction consistent with the time history and suppress responses to transient changes to the optic flow field. Our findings support recurrent competitive temporal dynamics as a crucial mechanism underlying the robustness and stability of perception of heading. PMID:27341686

  16. Advanced Techniques for Assessment of Postural and Locomotor Ataxia, Spatial Orientation, and Gaze Stability

    NASA Technical Reports Server (NTRS)

    Wall, Conrad., III

    1999-01-01

    In addition to adapting to microgravity, major neurovestibular problems of space flight include postflight difficulties with standing, walking, turning corners, and other activities that require stable upright posture and gaze stability. These difficulties inhibit astronauts' ability to stand or escape from their vehicle during emergencies. The long-ter7n goal of the NSBRI is the development of countermeasures to ameliorate the effects of long duration space flight. These countermeasures must be tested with valid and reliable tools. This project aims to develop quantitative, parametric approaches for assessing gaze stability and spatial orientation during normal gait and when gait is perturbed. Two of this year's most important findings concern head fixation distance and ideal trajectory analysis. During a normal cycle of walking the head moves up and down linearly. A simultaneous angular pitching motion of the head keeps it aligned toward an imaginary point in space at a distance of about one meter in front of a subject and along the line of march. This distance is called the head fixation distance. Head fixation distance provides the fundamental framework necessary for understanding the functional significance of the vestibular reflexes that couple head motion to eye motion. This framework facilitates the intelligent design of counter-measures for the effects of exposure to microgravity upon the vestibular ocular reflexes. Ideal trajectory analysis is a simple candidate countermeasure based upon quantifying body sway during repeated up and down stair stepping. It provides one number that estimates the body sway deviation from an ideal sinusoidal body sway trajectory normalized on the subject's height. This concept has been developed with NSBRI funding in less than one year. These findings are explained in more detail below. Compared to assessments of the vestibuo-ocular reflex, analysis of vestibular effects on locomotor function is relatively less well developed and quantified. We are improving this situation by applying methodologies such as nonlinear orbital stability to quantify responses and by using multivariate statistical approaches to link together the responses across separate tests. In this way we can exploit the information available and increase the ability to discriminate between normal and pathological responses. Measures of stability and orientation are compared to measures such as dynamic visual acuity and with balance function tests. The responses of normal human subjects and of patients having well documented pathophysiologies are being characterized. When these studies are completed, we should have a clearer idea about normal and abnormal patterns of eye, head, and body movements during locomotion and their stability in a wide range of environments. We plan eventually to use this information to validate the efficacy of candidate neurovestibular and neuromuscular rehabilitative techniques. Some representative studies made during this year are summarized.

  17. Domain decomposition and matching for time-domain analysis of motions of ships advancing in head sea

    NASA Astrophysics Data System (ADS)

    Tang, Kai; Zhu, Ren-chuan; Miao, Guo-ping; Fan, Ju

    2014-08-01

    A domain decomposition and matching method in the time-domain is outlined for simulating the motions of ships advancing in waves. The flow field is decomposed into inner and outer domains by an imaginary control surface, and the Rankine source method is applied to the inner domain while the transient Green function method is used in the outer domain. Two initial boundary value problems are matched on the control surface. The corresponding numerical codes are developed, and the added masses, wave exciting forces and ship motions advancing in head sea for Series 60 ship and S175 containership, are presented and verified. A good agreement has been obtained when the numerical results are compared with the experimental data and other references. It shows that the present method is more efficient because of the panel discretization only in the inner domain during the numerical calculation, and good numerical stability is proved to avoid divergence problem regarding ships with flare.

  18. A head-up display for mid-air drone recovery

    NASA Technical Reports Server (NTRS)

    Augustine, W. L.; Heft, E. L.; Bowen, T. E.; Newman, R. L.

    1978-01-01

    During mid-air retrieval of parachute packages, the absence of a natural horizon creates serious difficulties for the pilot of the recovery helicopter. A head-up display (HUD) was tested in an attempt to solve this problem. Both a roll-stabilized HUD and a no-roll (pitch only) HUD were tested. The results show that fewer missed passes occurred with the roll-stabilized HUD when the horizon was obscured. The pilots also reported that the workload was greatly reduced. Roll-stabilization was required to prevent vertigo when flying in the absence of a natural horizon. Any HUD intended for mid-air retrieval should display pitch, roll, sideslip, airspeed, and vertical velocity.

  19. Pyrrolo-dC Metal-Mediated Base Pairs in the Reverse Watson-Crick Double Helix: Enhanced Stability of Parallel DNA and Impact of 6-Pyridinyl Residues on Fluorescence and Silver-Ion Binding.

    PubMed

    Yang, Haozhe; Mei, Hui; Seela, Frank

    2015-07-06

    Reverse Watson-Crick DNA with parallel-strand orientation (ps DNA) has been constructed. Pyrrolo-dC (PyrdC) nucleosides with phenyl and pyridinyl residues linked to the 6 position of the pyrrolo[2,3-d]pyrimidine base have been incorporated in 12- and 25-mer oligonucleotide duplexes and utilized as silver-ion binding sites. Thermal-stability studies on the parallel DNA strands demonstrated extremely strong silver-ion binding and strongly enhanced duplex stability. Stoichiometric UV and fluorescence titration experiments verified that a single (2py) PyrdC-(2py) PyrdC pair captures two silver ions in ps DNA. A structure for the PyrdC silver-ion base pair that aligns 7-deazapurine bases head-to-tail instead of head-to-head, as suggested for canonical DNA, is proposed. The silver DNA double helix represents the first example of a ps DNA structure built up of bidentate and tridentate reverse Watson-Crick base pairs stabilized by a dinuclear silver-mediated PyrdC pair. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Head formation requires Dishevelled degradation that is mediated by March2 in concert with Dapper1.

    PubMed

    Lee, Hyeyoon; Cheong, Seong-Moon; Han, Wonhee; Koo, Youngmu; Jo, Saet-Byeol; Cho, Gun-Sik; Yang, Jae-Seong; Kim, Sanguk; Han, Jin-Kwan

    2018-04-10

    Dishevelled (Dvl/Dsh) is a key scaffold protein that propagates Wnt signaling essential for embryogenesis and homeostasis. However, whether the antagonism of Wnt signaling that is necessary for vertebrate head formation can be achieved through regulation of Dsh protein stability is unclear. Here, we show that membrane-associated RING-CH2 (March2), a RING-type E3 ubiquitin ligase, antagonizes Wnt signaling by regulating the turnover of Dsh protein via ubiquitin-mediated lysosomal degradation in the prospective head region of Xenopus We further found that March2 acquires regional and functional specificities for head formation from the Dsh-interacting protein Dapper1 (Dpr1). Dpr1 stabilizes the interaction between March2 and Dsh in order to mediate ubiquitylation and the subsequent degradation of Dsh protein only in the dorso-animal region of Xenopus embryo. These results suggest that March2 restricts cytosolic pools of Dsh protein and reduces the need for Wnt signaling in precise vertebrate head development. © 2018. Published by The Company of Biologists Ltd.

  1. Postural Instability Caused by Extended Bed Rest Is Alleviated by Brief Daily Exposure to Low Magnitude Mechanical Signals

    PubMed Central

    Muir, Jesse; Judex, Stefan; Qin, Yi-Xian; Rubin, Clinton

    2011-01-01

    Loss of postural stability, as exacerbated by chronic bed rest, aging, neuromuscular injury or disease, results in a marked increase in the risk of falls, potentiating severe injury and even death. To investigate the capacity of low magnitude mechanical signals (LMMS) to retain postural stability under conditions conducive to its decline, twenty-nine healthy adult subjects underwent 90 days of 6-degree head down tilt bed-rest. Treated subjects underwent a daily 10 minute regimen of 30 Hz LMMS at either a 0.3g-force (n=12) or 0.5g force (n=5). Control subjects (n=13) received no LMMS treatment. Postural stability, quantified by dispersions of the plantar-based center of pressure, deteriorated significantly from baseline in control subjects, with displacement and velocity at 60d increasing 98.7% and 193% respectively, while the LMMS group increased only 26.7% and 6.4%, reflecting a 73% and 97% relative retention in stability as compared to control. Increasing LMMS magnitude from 0.3 to 0.5g had no significant influence on outcomes. LMMS failed to spare loss of muscle extension strength, but helped to retain flexion strength (e.g., 46.2% improved retention of baseline concentric flexion strength vs. untreated controls; p=0.01). These data suggest the potential of extremely small mechanical signals as a non-invasive means of preserving postural control under the challenge of chronic bed rest, and may ultimately represent non-pharmacologic means of reducing the risk of debilitating falls in elderly and infirm. PMID:21273076

  2. An analysis of a nonlinear instability in the implementation of a VTOL control system

    NASA Technical Reports Server (NTRS)

    Weber, J. M.

    1982-01-01

    The contributions to nonlinear behavior and unstable response of the model following yaw control system of a VTOL aircraft during hover were determined. The system was designed as a state rate feedback implicit model follower that provided yaw rate command/heading hold capability and used combined full authority parallel and limited authority series servo actuators to generate an input to the yaw reaction control system of the aircraft. Both linear and nonlinear system models, as well as describing function linearization techniques were used to determine the influence on the control system instability of input magnitude and bandwidth, series servo authority, and system bandwidth. Results of the analysis describe stability boundaries as a function of these system design characteristics.

  3. Joint Force Quarterly. Issue 68, 1st Quarter, January 2013

    DTIC Science & Technology

    2013-01-01

    the regional players to see the stabilization of Afghanistan. It is not until we start to peel the onion back and examine the complex rela...The raiders set up blocking positions to the east of the airfield and then headed west with a small element to seize the port cities of Banana and...of resupply: the Atlan- tic Ocean port of Banana , which lies at the mouth of the Congo River. The Rwandans knew that if they could control the port

  4. Differences of ballet turns (pirouette) performance between experienced and novice ballet dancers.

    PubMed

    Lin, Chia-Wei; Chen, Shing-Jye; Su, Fong-Chin; Wu, Hong-Wen; Lin, Cheng-Feng

    2014-09-01

    This study investigated the different postural control strategies exhibited by experienced and novice dancers in ballet turns (pirouettes). Thirteen novice and 13 experienced dancers performed ballet turns with dominant-leg support. The peak push force was measured in the double-leg support phase. The inclination angles of rotation axis with respect to vertical axis were calculated in the early single-leg support phase as well as the initiation sequence of ankle, knee, and hip joints on the supporting leg. Moreover, the anchoring index of the head was computed in the transverse plane during turning. The novice dancers applied a greater push force, an increased inclination angle of rotation axis, and an insufficient proximal-to-distal extension sequence pattern. The novice dancers also had a smaller head-anchoring index compared with experienced dancers, which meant novice dancers were not using a space target as a stability reference. A poorer performance in novice dancers could result from higher push force in propulsion, lack of a "proximal-to-distal extension sequence" pattern, and lack of visual spotting for postural stability. Training on sequential initiation of lower-extremity joints and rehearsal of visual spotting are essential for novice dancers to obtain better performance on ballet turns.

  5. Three-dimensional vestibular eye and head reflexes of the chameleon: characteristics of gain and phase and effects of eye position on orientation of ocular rotation axes during stimulation in yaw direction.

    PubMed

    Haker, H; Misslisch, H; Ott, M; Frens, M A; Henn, V; Hess, K; Sándor, P S

    2003-07-01

    We investigated gaze-stabilizing reflexes in the chameleon using the three-dimensional search-coil technique. Animals were rotated sinusoidally around an earth-vertical axis under head-fixed and head-free conditions, in the dark and in the light. Gain, phase and the influence of eye position on vestibulo-ocular reflex rotation axes were studied. During head-restrained stimulation in the dark, vestibulo-ocular reflex gaze gains were low (0.1-0.3) and phase lead decreased with increasing frequencies (from 100 degrees at 0.04 Hz to < 30 degrees at 1 Hz). Gaze gains were larger during stimulation in the light (0.1-0.8) with a smaller phase lead (< 30 degrees) and were close to unity during the head-free conditions (around 0.6 in the dark, around 0.8 in the light) with small phase leads. These results confirm earlier findings that chameleons have a low vestibulo-ocular reflex gain during head-fixed conditions and stimulation in the dark and higher gains during head-free stimulation in the light. Vestibulo-ocular reflex eye rotation axes were roughly aligned with the head's rotation axis and did not systematically tilt when the animals were looking eccentrically, up- or downward (as predicted by Listing's Law). Therefore, vestibulo-ocular reflex responses in the chameleon follow a strategy, which optimally stabilizes the entire retinal images, a result previously found in non-human primates.

  6. Motion control of rigid bodies in SE(3)

    NASA Astrophysics Data System (ADS)

    Roza, Ashton

    This thesis investigates the control of motion for a general class of vehicles that rotate and translate in three-space, and are propelled by a thrust vector which has fixed direction in body frame. The thesis addresses the problems of path following and position control. For path following, a feedback linearization controller is presented that makes the vehicle follow an arbitrary closed curve while simultaneously allowing the designer to specify the velocity profile of the vehicle on the path and its heading. For position control, a two-stage approach is presented that decouples position control from attitude control, allowing for a modular design and yielding almost global asymptotic stability of any desired hovering equilibrium. The effectiveness of the proposed method is verified both in simulation and experimentally by means of a hardware-in-the-loop setup emulating a co-axial helicopter.

  7. Three Year RSA Evaluation of Vitamin E Diffused Highly Cross-linked Polyethylene Liners and Cup Stability.

    PubMed

    Sillesen, Nanna H; Greene, Meridith E; Nebergall, Audrey K; Nielsen, Poul T; Laursen, Mogens B; Troelsen, Anders; Malchau, Henrik

    2015-07-01

    Vitamin E diffusion into highly cross-linked polyethylene (E-XLPE) is a method for enhancing oxidative stability of acetabular liners. The purpose of this study was to evaluate in vivo penetration of E-XLPE using radiostereometric analysis (RSA). Eighty-four hips were recruited into a prospective 10-year RSA. This is the first evaluation of the multicenter cohort after 3-years. All patients received E-XLPE liners (E1, Biomet) and porous-titanium coated cups (Regenerex, Biomet). There was no difference (P=0.450) in median femoral head penetration into the E-XLPE liners at 3-years comparing cobalt-chrome heads (-0.028mm; inter-quartile range (IQR) - 0.065 to 0.047) with ceramic heads (-0.043mm, IQR - 0.143to0.042). The 3-year follow-up indicates minimal E-XLPE liner penetration regardless of head material and minimal early cup movement. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Will New Metal Heads Restore Mechanical Integrity of Corroded Trunnions?

    PubMed

    Derasari, Aditya; Gold, Jonathan E; Ismaily, Sabir; Noble, Philip C; Incavo, Stephen J

    2017-04-01

    Metal wear and corrosion from modular junctions in total hip arthroplasty can lead to further unwanted surgery. Trunnion tribocorrosion is recognized as an important contributor to failure. This study was performed to determine if new metal heads restore mechanical integrity of the original modular junction after impaction on corroded trunnions, and assess which variables affect stability of the new interface created at revision total hip arthroplasty. Twenty-two trunnions, cobalt-chromium (CoCr) and titanium alloy (TiAIV), (CoCr, n = 12; TiAIV, n = 10) and new metal heads were used, 10 trunnions in pristine condition and 12 with corrosion damage. Test states were performed using an MTS Machine and included the following: 1, Assembly; 2, Disassembly; 3, Assembly; 4, Toggling; and 5, Disassembly. During loading, three-dimensional motion of the head-trunnion junction was measured using a custom jig. There were no statistical differences in the tested mechanical properties between corroded and pristine trunnions implanted with a new metal femoral head. Average micromotion of the head versus trunnion interface was greatest at the start of loading, stabilizing after approximately 50 loading cycles at an average of 30.6 ± 3.2 μm. Corrosion at the trunnion does not disrupt mechanical integrity of the junction when a CoCr head is replaced with a CoCr trunnion. However, increased interface motion of a new metal head on a corroded titanium trunnion requires additional study. The evaluation of ball head size on mechanical integrity of trunnions would also be a potential subject of future investigation, as increasing the ball head size at the time of revision is not uncommon in revisions today. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Disequilibrium After Traumatic Brain Injury: Vestibular Mechanisms

    DTIC Science & Technology

    2011-09-01

    of otolith signal processing, including the integration of head acceleration26 and the disambiguation of linear ac- celeration signals related to tilt ...Foveal versus full-field visual stabilization strategies for translational and rotational head movements. J. Neurosci. 23: 1104–1108. 14. Walker, M.F., M...in the vestibular reflexes that compensate for linear movements of the head and body during standing and walking. The experimental protocol has two

  10. The Talin Head Domain Reinforces Integrin-Mediated Adhesion by Promoting Adhesion Complex Stability and Clustering

    PubMed Central

    Ellis, Stephanie J.; Lostchuck, Emily; Goult, Benjamin T.; Bouaouina, Mohamed; Fairchild, Michael J.; López-Ceballos, Pablo; Calderwood, David A.; Tanentzapf, Guy

    2014-01-01

    Talin serves an essential function during integrin-mediated adhesion in linking integrins to actin via the intracellular adhesion complex. In addition, the N-terminal head domain of talin regulates the affinity of integrins for their ECM-ligands, a process known as inside-out activation. We previously showed that in Drosophila, mutating the integrin binding site in the talin head domain resulted in weakened adhesion to the ECM. Intriguingly, subsequent studies showed that canonical inside-out activation of integrin might not take place in flies. Consistent with this, a mutation in talin that specifically blocks its ability to activate mammalian integrins does not significantly impinge on talin function during fly development. Here, we describe results suggesting that the talin head domain reinforces and stabilizes the integrin adhesion complex by promoting integrin clustering distinct from its ability to support inside-out activation. Specifically, we show that an allele of talin containing a mutation that disrupts intramolecular interactions within the talin head attenuates the assembly and reinforcement of the integrin adhesion complex. Importantly, we provide evidence that this mutation blocks integrin clustering in vivo. We propose that the talin head domain is essential for regulating integrin avidity in Drosophila and that this is crucial for integrin-mediated adhesion during animal development. PMID:25393120

  11. Physiological stability and renal clearance of ultrasmall zwitterionic gold nanoparticles: Ligand length matters

    NASA Astrophysics Data System (ADS)

    Ning, Xuhui; Peng, Chuanqi; Li, Eric S.; Xu, Jing; Vinluan, Rodrigo D.; Yu, Mengxiao; Zheng, Jie

    2017-05-01

    Efficient renal clearance has been observed from ultrasmall zwitterionic glutathione-coated gold nanoparticles (GS-AuNPs), which have broad preclinical applications in cancer diagnosis and kidney functional imaging. However, origin of such efficient renal clearance is still not clear. Herein, we conducted head-to-head comparison on physiological stability and renal clearance of two zwitterionic luminescent AuNPs coated with cysteine and glycine-cysteine (Cys-AuNPs and Gly-Cys-AuNPs), respectively. While both of them exhibited similar surface charges and the same core sizes, additional glycine slightly increased the hydrodynamic diameter of the AuNPs by 0.4 nm but significantly enhanced physiological stability of the AuNPs as well as altered their clearance pathways. These studies indicate that the ligand length, in addition to surface charges and size, also plays a key role in the physiological stability and renal clearance of ultrasmall zwitterionic inorganic NPs.

  12. Compensatory mechanisms of balance to the scaling of arm-swing frequency.

    PubMed

    Ko, Ji Hyun; Wang, Zheng; Challis, John H; Newell, Karl M

    2015-11-05

    The present study investigated the contribution of the Hof (2007) mechanism 1 (M1-moving the center of pressure (COP) with respect to the vertical projection of the center of mass (COMTotal)); and mechanism 2 (M2-rotating the trunk and upper limbs around the COMTotal) to postural control and the stability of COP-COMTotal cophase as a function of lateral arm-swing frequency. Young adults were instructed to stand still on a force platform while alternating their arm swinging from above the head to the side of their thigh to create perturbations to postural control. Scaling the frequency of arm-swing (random step changes of 0.2 Hz within a bandwidth of 0.2 to 1.6 Hz) increased the SD of COP but decreased the SD of COMTotal. Increments in arm-swing frequency induced a progressive increase in M1 and decrease in M2 in terms of their relative contribution to postural stability. The cophase between COP and COMTotal became more tightly in-phase over increments of arm-swing frequency. These findings show an adaptive compensatory role of M1 and M2 within the stability of COP-COMTotal coupling in the regulation of human balance control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. "Far" and "Near" Visual Acuity While Walking and the Collective Contributions of Non-Ocular Mechanisms to Gaze Stabilization

    NASA Technical Reports Server (NTRS)

    Peters, Brian T.; vanEmmerik, Richard E. A.; Bloomberg, Jacob J.

    2006-01-01

    Gaze stabilization was quantified in subjects (n=11) as they walked on a motorized treadmill (1.8 m/s) and viewed visual targets at two viewing distances. A "far" target was positioned at 4 m (FAR) in front of the subject and the "near" target was placed at a distance of 0.5 m (NEAR). A direct measure of visual acuity was used to assess the overall effectiveness of the gaze stabilization system. The contributions of nonocular mechanisms to the gaze goal were also quantified using a measure of the distance between the subject and point in space where fixation of the visual target would require the least eye movement amplitude (i.e. the head fixation distance (HFD)). Kinematic variables mirrored those of previous investigations with the vertical trunk translation and head pitch signals, and the lateral translation and head yaw signals maintaining what appear as antiphase relationships. However, an investigation of the temporal relationships between the maxima and minima of the vertical translation and head pitch signals show that while the maximum in vertical translation occurs at the point of the minimum head pitch signal, the inverse is not true. The maximum in the head pitch signal lags the vertical translation minimum by an average of greater than 12 percent of the step cycle time. Three HFD measures, one each for data in the sagittal and transverse planes, and one that combined the movements from both planes, all revealed changes between the FAR and NEAR target viewing conditions. This reorganization of the nonocular degrees of freedom while walking was consistent with a strategy to reduce the magnitude of the eye movements required when viewing the NEAR target. Despite this reorganization, acuity measures show that image stabilization is not occurring while walking and viewing the NEAR target. Group means indicate that visual acuity is not affected while walking in the FAR condition, but a decrement of 0.15 logMAR (i.e. 1.5 eye chart lines) exists between the standing and walking acuity measures when viewing the NEAR target.

  14. Custos controls β-catenin to regulate head development during vertebrate embryogenesis.

    PubMed

    Komiya, Yuko; Mandrekar, Noopur; Sato, Akira; Dawid, Igor B; Habas, Raymond

    2014-09-09

    Precise control of the canonical Wnt pathway is crucial in embryogenesis and all stages of life, and dysregulation of this pathway is implicated in many human diseases including cancers and birth defect disorders. A key aspect of canonical Wnt signaling is the cytoplasmic to nuclear translocation of β-catenin, a process that remains incompletely understood. Here we report the identification of a previously undescribed component of the canonical Wnt signaling pathway termed Custos, originally isolated as a Dishevelled-interacting protein. Custos contains casein kinase phosphorylation sites and nuclear localization sequences. In Xenopus, custos mRNA is expressed maternally and then widely throughout embryogenesis. Depletion or overexpression of Custos produced defective anterior head structures by inhibiting the formation of the Spemann-Mangold organizer. In addition, Custos expression blocked secondary axis induction by positive signaling components of the canonical Wnt pathway and inhibited β-catenin/TCF-dependent transcription. Custos binds to β-catenin in a Wnt responsive manner without affecting its stability, but rather modulates the cytoplasmic to nuclear translocation of β-catenin. This effect on nuclear import appears to be the mechanism by which Custos inhibits canonical Wnt signaling. The function of Custos is conserved as loss-of-function and gain-of-function studies in zebrafish also demonstrate a role for Custos in anterior head development. Our studies suggest a role for Custos in fine-tuning canonical Wnt signal transduction during embryogenesis, adding an additional layer of regulatory control in the Wnt-β-catenin signal transduction cascade.

  15. Scaffold design of trivalent chelator heads dictates high-affinity and stable His-tagged protein labeling in vitro and in cellulo.

    PubMed

    Gatterdam, Karl; Joest, Eike F; Gatterdam, Volker; Tampé, Robert

    2018-05-29

    Small chemical/biological interaction pairs are at the forefront in tracing proteins' function and interaction at high signal-to-background ratio in cellular pathways. Pharma ventures have eager plans to develop trisNTA probes for in vitro and in vivo screening of His-tagged protein targets. However, the optimal design of scaffold, linker, and chelator head yet deserves systematic investigations to achieve highest affinity and kinetic stability for in vitro and especially cell applications. In this study, we report on a library of N-nitrilotriacetic acid (NTA) based multivalent chelator heads (MCHs) built up on linear, cyclic, and dendritic scaffolds and contrast these with regard to their binding affinity and stability for labeling of cellular His-tagged proteins. Furthermore, we assign a new approach for tracing cellular target proteins at picomolar probe concentrations in cells. Finally, we describe fundamental differences between the MCH scaffold and define a cyclic trisNTA chelator, which displays the highest affinity and kinetic stability of all reversible, low-molecular weight interaction pairs. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Unconstrained tripolar hip implants: effect on hip stability.

    PubMed

    Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan

    2007-02-01

    Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.

  17. Design and preliminary biomechanical analysis of artificial cervical joint complex.

    PubMed

    Jian, Yu; Lan-Tao, Liu; Zhao, Jian-ning; Jian-ning, Zhao

    2013-06-01

    To design an artificial cervical joint complex (ACJC) prosthesis for non-fusion reconstruction after cervical subtotal corpectomy, and to evaluate the biomechanical stability, preservation of segment movements and influence on adjacent inter-vertebral movements of this prosthesis. The prosthesis was composed of three parts: the upper/lower joint head and the middle artificial vertebrae made of Cobalt-Chromium-Molybdenum (Co-Cr-Mo) alloy and polyethylene with a ball-and-socket joint design resembling the multi-axial movement in normal inter-vertebral spaces. Biomechanical tests of intact spine (control), Orion locking plate system and ACJC prosthesis were performed on formalin-fixed cervical spine specimens from 21 healthy cadavers to compare stability, range of motion (ROM) of the surgical segment and ROM of adjacent inter-vertebral spaces. As for stability of the whole lower cervical spine, there was no significant difference of flexion, extension, lateral bending and torsion between intact spine group and ACJC prosthesis group. As for segment movements, difference in flexion, lateral bending or torsion between ACJC prosthesis group and control group was not statistically significant, while ACJC prosthesis group showed an increase in extension (P < 0.05) compared to that of the control group. In addition, ACJC prosthesis group demonstrated better flexion, extension and lateral bending compared to those of Orion plating system group (P < 0.05). Difference in adjacent inter-vertebral ROM of the ACJC prosthesis group was not statistically significant compared to that of the control group. After cervical subtotal corpectomy, reconstruction with ACJC prosthesis not only obtained instant stability, but also reserved segment motions effectively, without abnormal gain of mobility at adjacent inter-vertebral spaces.

  18. Novel polymeric micelles for insect pest control: encapsulation of essential oil monoterpenes inside a triblock copolymer shell for head lice control.

    PubMed

    Lucia, Alejandro; Toloza, Ariel Ceferino; Guzmán, Eduardo; Ortega, Francisco; Rubio, Ramón G

    2017-01-01

    Essential oil components (EOCs) are molecules with interesting application in pest control, these have been evaluated against different insect pest from more than 100 years, but their practical use is rather limited. Thus, the enhancement of their bioavailability and manageability due to their dispersion in water can open new perspective for the preparation of formulations for the control of insect pest. In this work, we studied the encapsulation of different monoterpenes in a poloxamer shell in order to prepare aqueous formulations that can be used for the development of platforms used in pest control. Micellar systems containing a 5 wt% of poloxamer 407 and 1.25 wt% of the different monoterpenes were prepared. Dynamic Light Scattering (DLS) experiments were carried out to characterize the dispersion of the EOCs in water. The pediculicidal activity of these micellar systems was tested on head lice using an ex vivo immersion test. The poloxamers allowed the dispersion of EOCs in water due to their encapsulation inside the hydrophobic core of the copolymer micelles. From this study, we concluded that it is possible to make stable micellar systems containing water (>90 wt%), 1.25 wt% of different monoterpenes and a highly safe polymer (5wt% Poloxamer 407). These formulations were effective against head lice with mortality ranging from 30 to 60%, being the most effective emulsions those containing linalool, 1,8-cineole, α -terpineol, thymol, eugenol, geraniol and nonyl alcohol which lead to mortalities above 50%. Since these systems showed good pediculicidal activity and high physicochemical stability, they could be a new route for the green fabrication of biocompatible and biosustainable insecticide formulations.

  19. Novel polymeric micelles for insect pest control: encapsulation of essential oil monoterpenes inside a triblock copolymer shell for head lice control

    PubMed Central

    Guzmán, Eduardo; Ortega, Francisco; Rubio, Ramón G.

    2017-01-01

    Background Essential oil components (EOCs) are molecules with interesting application in pest control, these have been evaluated against different insect pest from more than 100 years, but their practical use is rather limited. Thus, the enhancement of their bioavailability and manageability due to their dispersion in water can open new perspective for the preparation of formulations for the control of insect pest. In this work, we studied the encapsulation of different monoterpenes in a poloxamer shell in order to prepare aqueous formulations that can be used for the development of platforms used in pest control. Methods Micellar systems containing a 5 wt% of poloxamer 407 and 1.25 wt% of the different monoterpenes were prepared. Dynamic Light Scattering (DLS) experiments were carried out to characterize the dispersion of the EOCs in water. The pediculicidal activity of these micellar systems was tested on head lice using an ex vivo immersion test. Results The poloxamers allowed the dispersion of EOCs in water due to their encapsulation inside the hydrophobic core of the copolymer micelles. From this study, we concluded that it is possible to make stable micellar systems containing water (>90 wt%), 1.25 wt% of different monoterpenes and a highly safe polymer (5wt% Poloxamer 407). These formulations were effective against head lice with mortality ranging from 30 to 60%, being the most effective emulsions those containing linalool, 1,8-cineole, α-terpineol, thymol, eugenol, geraniol and nonyl alcohol which lead to mortalities above 50%. Discussion Since these systems showed good pediculicidal activity and high physicochemical stability, they could be a new route for the green fabrication of biocompatible and biosustainable insecticide formulations. PMID:28439460

  20. Head-mounted LED for optogenetic experiments of freely-behaving animal

    NASA Astrophysics Data System (ADS)

    Kwon, Ki Yong; Gnade, Andrew G.; Rush, Alexander D.; Patten, Craig D.

    2016-03-01

    Recent developments in optogenetics have demonstrated the ability to target specific types of neurons with sub-millisecond temporal precision via direct optical stimulation of genetically modified neurons in the brain. In most applications, the beam of a laser is coupled to an optical fiber, which guides and delivers the optical power to the region of interest. Light emitting diodes (LEDs) are an alternative light source for optogenetics and they provide many advantages over a laser based system including cost, size, illumination stability, and fast modulation. Their compact size and low power consumption make LEDs suitable light sources for a wireless optogenetic stimulation system. However, the coupling efficiency of an LED's output light into an optical fiber is lower than a laser due to its noncollimated output light. In typical chronic optogenetic experiment, the output of the light source is transmitted to the brain through a patch cable and a fiber stub implant, and this configuration requires two fiber-to-fiber couplings. Attenuation within the patch cable is potential source of optical power loss. In this study, we report and characterize a recently developed light delivery method for freely-behaving animal experiments. We have developed a head-mounted light source that maximizes the coupling efficiency of an LED light source by eliminating the need for a fiber optic cable. This miniaturized LED is designed to couple directly to the fiber stub implant. Depending on the desired optical power output, the head-mounted LED can be controlled by either a tethered (high power) or battery-powered wireless (moderate power) controller. In the tethered system, the LED is controlled through 40 gauge micro coaxial cable which is thinner, more flexible, and more durable than a fiber optic cable. The battery-powered wireless system uses either infrared or radio frequency transmission to achieve real-time control. Optical, electrical, mechanical, and thermal characteristics of the head-mounted LED were evaluated.

  1. Getting Ahead of Oneself: Anticipation and the Vestibulo-ocular Reflex (VOR)

    PubMed Central

    King, W. Michael

    2014-01-01

    Compensatory counter-rotations of the eyes provoked by head turns are commonly attributed to the vestibulo-ocular reflex (VOR). A recent study in guinea pigs demonstrates, however, that this assumption is not always valid. During voluntary head turns, guinea pigs make highly accurate compensatory eye movements that occur with zero or even negative latencies with respect to the onset of the provoking head movements. Furthermore, the anticipatory eye movements occur in animals with bilateral peripheral vestibular lesions, thus confirming that they have an extra vestibular origin. This discovery suggests the possibility that anticipatory responses might also occur in other species including humans and non-human primates, but have been overlooked and mistakenly identified as being produced by the VOR. This review will compare primate and guinea pig vestibular physiology in light of these new findings. A unified model of vestibular and cerebellar pathways will be presented that is consistent with current data in primates and guinea pigs. The model is capable of accurately simulating compensatory eye movements to active head turns (anticipatory responses) and to passive head perturbations (VOR induced eye movements) in guinea pigs and in human subjects who use coordinated eye and head movements to shift gaze direction in space. Anticipatory responses provide new evidence and opportunities to study the role of extra vestibular signals in motor control and sensory-motor transformations. Exercises that employ voluntary head turns are frequently used to improve visual stability in patients with vestibular hypofunction. Thus, a deeper understanding of the origin and physiology of anticipatory responses could suggest new translational approaches to rehabilitative training of patients with bilateral vestibular loss. PMID:23370320

  2. FAR and NEAR Target Dynamic Visual Acuity: A Functional Assessment of Canal and Otolith Performance

    NASA Technical Reports Server (NTRS)

    Peters, Brian T.; Brady, Rachel A.; Landsness, Eric C.; Black, F. Owen; Bloomberg, Jacob J.

    2004-01-01

    Upon their return to earth, astronauts experience the effects of vestibular adaptation to microgravity. The postflight changes in vestibular information processing can affect postural and locomotor stability and may lead to oscillopsia during activities of daily living. However, it is likely that time spent in microgravity affects canal and otolith function differently. As a result, the isolated rotational stimuli used in traditional tests of canal function may fail to identify vestibular deficits after spaceflight. Also, the functional consequences of deficits that are identified often remain unknown. In a gaze control task, the relative contributions of the canal and otolith organs are modulated with viewing distance. The ability to stabilize gaze during a perturbation, on visual targets placed at different distances from the head may therefore provide independent insight into the function of this systems. Our goal was to develop a functional measure of gaze control that can also offer independent information about the function of the canal and otolith organs.

  3. The influence of an immersive virtual environment on the segmental organization of postural stabilizing responses.

    PubMed

    Keshner, E A; Kenyon, R V

    2000-01-01

    We examined the effect of a 3-dimensional stereoscopic scene on segmental stabilization. Eight subjects participated in static sway and locomotion experiments with a visual scene that moved sinusoidally or at constant velocity about the pitch or roll axes. Segmental displacements, Fast Fourier Transforms, and Root Mean Square values were calculated. In both pitch and roll, subjects exhibited greater magnitudes of motion in head and trunk than ankle. Smaller amplitudes and frequent phase reversals suggested control of the ankle by segmental proprioceptive inputs and ground reaction forces rather than by the visual-vestibular signals. Postural controllers may set limits of motion at each body segment rather than be governed solely by a perception of the visual vertical. Two locomotor strategies were also exhibited, implying that some subjects could override the effect of the roll axis optic flow field. Our results demonstrate task dependent differences that argue against using static postural responses to moving visual fields when assessing more dynamic tasks.

  4. Discriminability of Prediction Artifacts in a Time Delayed Virtual Environment

    NASA Technical Reports Server (NTRS)

    Adelstein, Bernard D.; Jung, Jae Y.; Ellis, Stephen R.

    2001-01-01

    Overall latency remains an impediment to perceived image stability and consequently to human performance in virtual environment (VE) systems. Predictive compensators have been proposed as a means to mitigate these shortcomings, but they introduce rendering errors because of induced motion overshoot and heightened noise. Discriminability of these compensator artifacts was investigated by a protocol in which head tracked image stability for 35 ms baseline VE system latency was compared against artificially added (16.7 to 100 ms) latency compensated by a previously studied Kalman Filter (K-F) predictor. A control study in which uncompensated 16.7 to 100 ms latencies were compared against the baseline was also performed. Results from 10 subjects in the main study and 8 in the control group indicate that predictive compensation artifacts are less discernible than the disruptions of uncompensated time delay for the shorter but not the longer added latencies. We propose that noise magnification and overshoot are contributory cues to the presence of predictive compensation.

  5. Modulation of head movement control in humans during treadmill walking

    NASA Technical Reports Server (NTRS)

    Mulavara, Ajitkumar P.; Verstraete, Mary C.; Bloomberg, Jacob J.

    2002-01-01

    The purpose of this study was to investigate the coordination of the head relative to the trunk within a gait cycle during gaze fixation. Nine normal subjects walked on a motorized treadmill driven at 1.79 m/s (20 s trials) while fixing their gaze on a centrally located earth-fixed target positioned at a distance of 2 m from their eyes. The net and relative angular motions of the head about the three axes of rotations, as well as the corresponding values for the moments acting on it relative to the trunk during the gait cycle were quantified and used as measures of coordination. The average net moment, as well as the average moments about the different axes were significantly different (P<0.01) between the high impact and low/no impact phases of the gait cycle. However, the average net angular displacement as well as the average angular displacement about the axial rotation axis of the head relative to the trunk was maintained uniform (P>0.01) throughout the gait cycle. The average angular displacement about the lateral bending axis was significantly increased (P<0.01) during the high impact phase while that about the flexion-extension axis was significantly decreased (P<0.01) throughout the gait cycle. Thus, the coordination of the motion of the head relative to the trunk during walking is dynamically modulated depending on the behavioral events occurring in the gait cycle. This modulation may serve to aid stabilization of the head by counteracting the force variations acting on the upper body that may aid in the visual fixation of targets during walking.

  6. Head stabilisation in fast running lizards.

    PubMed

    Goyens, Jana; Aerts, Peter

    2018-04-01

    The cyclic patterns of terrestrial animal locomotion are frequently perturbed in natural environments. The terrain can be complex or inclined, the substrate can move unexpectedly and animals can misjudge situations. Loosing stability due to perturbations increases the probability of capture by predators and decreases the chance of successful prey capture and winning intraspecific battles. When controlled corrective actions are necessary to negotiate perturbations, animals rely on their exteroceptive and proprioceptive senses to monitor the environment and their own body movements. The vestibular system in the inner ear perceives linear and angular accelerations. This information enables gaze stabilisation and the creation of a stable, world-bound reference frame for the integration of the information of other senses. During locomotion, both functions are known to be facilitated by head stabilisation in several animals with an erect posture. Animals with a sprawled body posture, however, undergo very large body undulations while running. Using high speed video recordings, we tested whether they nevertheless stabilise their head during running, and how this is influenced by perturbations. We found that running Acanthodactylus boskianus lizards strongly stabilise their head yaw rotations when running on a flat, straight runway: the head rotation amplitude is only 4.76±0.99°, while the adjacent trunk part rotates over 27.0±3.8°. Lateral head translations are not stabilised (average amplitude of 7.4±2.0mm). When the lizards are experimentally perturbed by a large and unexpected lateral substrate movement, lateral translations of both the head and the body decrease (on average by 1.52±0.81mm). At the same time, the rotations of the head and trunk also decrease (on average by 1.62°±7.21°). These results show that head stabilisation intensifies because of the perturbation, which emphasises the importance of vestibular perception and balance in these fast and manoeuvrable animals. Copyright © 2017 Elsevier GmbH. All rights reserved.

  7. Effectiveness of a Physical Activity Intervention for Head Start Preschoolers: A Randomized Intervention Study

    PubMed Central

    Davies, Patricia L.; Anderson, Jennifer; Kennedy, Catherine

    2013-01-01

    OBJECTIVES. The level of children’s motor skill proficiency may be an important determinant of their physical activity behaviors. This study assessed the efficacy of an intervention on gross motor skill performance, physical activity, and weight status of preschoolers. METHOD. The Food Friends: Get Movin’ With Mighty Moves® program was conducted in four Head Start centers. Measurements included the Peabody Developmental Motor Scales, pedometer counts, and body mass index (BMI) z scores. RESULTS. The intervention led to significant changes in gross motor skills in the treatment group (n = 98) compared with the control group (n = 103) and was a strong predictor of overall gross motor performance (gross motor quotient), locomotor, stability, and object manipulation skills. No intervention effect was found for physical activity levels or weight status. CONCLUSION. The intervention dose was adequate for enhancing gross motor skill performance but not for increasing physical activity levels or reducing BMI. PMID:23245780

  8. The NASA Performance Assessment Workstation: cognitive performance during head-down bed rest.

    PubMed

    Shehab, R L; Schlegel, R E; Schiflett, S G; Eddy, D R

    1998-01-01

    The NASA Performance Assessment Workstation was used to assess cognitive performance changes in eight males subjected to seventeen days of 6 degrees head-down bed rest. PAWS uses six performance tasks to assess directed and divided attention, spatial, mathematical, and memory skills, and tracking ability. Subjective scales assess overall fatigue and mood state. Subjects completed training trials, practice trials, bed rest trials, and recovery trials. The last eight practice trials and all bed rest trials were performed with subjects lying face-down on a gurney. In general, there was no apparent cumulative effect of bed rest. Following a short period of performance stabilization, a slight but steady trend of performance improvement was observed across all trials. For most tasks, this trend of performance improvement was enhanced during recovery. No statistically significant differences in performance were observed when comparing bed rest with the control period. Additionally, fatigue scores showed little change across all periods.

  9. The NASA performance assessment workstation: Cognitive performance during head-down bed rest

    NASA Astrophysics Data System (ADS)

    Shehab, Randa L.; Schlegel, Robert E.; Schiflett, Samuel G.; Eddy, Douglas R.

    The NASA Performance Assessment Workstation was used to assess cognitive performance changes in eight males subjected to seventeen days of 6 ° head-down bed rest. PAWS uses six performance tasks to assess directed and divided attention, spatial, mathematical, and memory skills, and tracking ability. Subjective scales assess overall fatigue and mood state. Subjects completed training trials, practice trials, bed rest trials, and recovery trials. The last eight practice trials and all bed rest trials were performed with subjects lying face-down on a gurney. In general, there was no apparent cumulative effect of bed rest. Following a short period of performance stabilization, a slight but steady trend of performance improvement was observed across all trials. For most tasks, this trend of performance improvement was enhanced during recovery. No statistically significant differences in performance were observed when comparing bed rest with the control period. Additionally, fatigue scores showed little change across all periods.

  10. The effect of a radial neck notch on press-fit stem stability: a biomechanical study on 7 cadavers.

    PubMed

    Shukla, Dave R; Sahu, Dipit C; Fitzsimmons, James S; An, Kai-Nan; O'Driscoll, Shawn W

    2018-03-01

    Minimal micromotion is necessary for osteointegration of cementless radial head prostheses. When radial head fractures extend longitudinally, where the neck cut for prosthetic replacement should be made is uncertain. We hypothesized that complete resection of the notched portion of a radial neck confers no advantage in initial stability compared with not resecting the defect and inserting the implant into a notched radial neck. The radii of 7 cadavers underwent radial head resection and implantation with a 25-mm-long press-fit radial head stem. Before implantation, a 5-mm-long notch that was less than 1-mm wide was made in the radial neck. After the stem-bone micromotion was recorded, the proximal 5 mm of radial neck, incorporating the entire notch, was cut away, the stem was inserted 5 mm further, and the resulting micromotion was recorded. The mean micromotion measured in the presence of a cortical notch was 51 ± 6 µm. After the neck was circumferentially cut and the stem was advanced, the micromotion (46 ± 9 µm) was not statistically significantly different. Initial stability of an adequately sized cementless stem in the presence of a 5-mm-long cortical notch was well within the threshold needed for bone ingrowth (<100 µm). In addition, there was no reduction of micromotion after the notch-containing portion of the radial neck was resected and the stem was advanced. Making a neck cut distal to a 5-mm-long, 1-mm-wide cortical notch does not confer added stability. Thus, surgeons can preserve bone stock and avoid an aggressive neck cut. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Spatial constancy mechanisms in motor control

    PubMed Central

    Medendorp, W. Pieter

    2011-01-01

    The success of the human species in interacting with the environment depends on the ability to maintain spatial stability despite the continuous changes in sensory and motor inputs owing to movements of eyes, head and body. In this paper, I will review recent advances in the understanding of how the brain deals with the dynamic flow of sensory and motor information in order to maintain spatial constancy of movement goals. The first part summarizes studies in the saccadic system, showing that spatial constancy is governed by a dynamic feed-forward process, by gaze-centred remapping of target representations in anticipation of and across eye movements. The subsequent sections relate to other oculomotor behaviour, such as eye–head gaze shifts, smooth pursuit and vergence eye movements, and their implications for feed-forward mechanisms for spatial constancy. Work that studied the geometric complexities in spatial constancy and saccadic guidance across head and body movements, distinguishing between self-generated and passively induced motion, indicates that both feed-forward and sensory feedback processing play a role in spatial updating of movement goals. The paper ends with a discussion of the behavioural mechanisms of spatial constancy for arm motor control and their physiological implications for the brain. Taken together, the emerging picture is that the brain computes an evolving representation of three-dimensional action space, whose internal metric is updated in a nonlinear way, by optimally integrating noisy and ambiguous afferent and efferent signals. PMID:21242137

  12. Ocular stability and set-point adaptation

    PubMed Central

    Jareonsettasin, P.; Leigh, R. J.

    2017-01-01

    A fundamental challenge to the brain is how to prevent intrusive movements when quiet is needed. Unwanted limb movements such as tremor impair fine motor control and unwanted eye drifts such as nystagmus impair vision. A stable platform is also necessary to launch accurate movements. Accordingly, nature has designed control systems with agonist (excitation) and antagonist (inhibition) muscle pairs functioning in push–pull, around a steady level of balanced tonic activity, the set-point. Sensory information can be organized similarly, as in the vestibulo-ocular reflex, which generates eye movements that compensate for head movements. The semicircular canals, working in coplanar pairs, one in each labyrinth, are reciprocally excited and inhibited as they transduce head rotations. The relative change in activity is relayed to the vestibular nuclei, which operate around a set-point of stable balanced activity. When a pathological imbalance occurs, producing unwanted nystagmus without head movement, an adaptive mechanism restores the proper set-point and eliminates the nystagmus. Here we used 90 min of continuous 7 T magnetic field labyrinthine stimulation (MVS) in normal humans to produce sustained nystagmus simulating vestibular imbalance. We identified multiple time-scale processes towards a new zero set-point showing that MVS is an excellent paradigm to investigate the neurobiology of set-point adaptation. This article is part of the themed issue ‘Movement suppression: brain mechanisms for stopping and stillness’. PMID:28242733

  13. DIPA-family coiled-coils bind conserved isoform-specific head domain of p120-catenin family: potential roles in hydrocephalus and heterotopia.

    PubMed

    Markham, Nicholas O; Doll, Caleb A; Dohn, Michael R; Miller, Rachel K; Yu, Huapeng; Coffey, Robert J; McCrea, Pierre D; Gamse, Joshua T; Reynolds, Albert B

    2014-09-01

    p120-catenin (p120) modulates adherens junction (AJ) dynamics by controlling the stability of classical cadherins. Among all p120 isoforms, p120-3A and p120-1A are the most prevalent. Both stabilize cadherins, but p120-3A is preferred in epithelia, whereas p120-1A takes precedence in neurons, fibroblasts, and macrophages. During epithelial-to-mesenchymal transition, E- to N-cadherin switching coincides with p120-3A to -1A alternative splicing. These isoforms differ by a 101-amino acid "head domain" comprising the p120-1A N-terminus. Although its exact role is unknown, the head domain likely mediates developmental and cancer-associated events linked to p120-1A expression (e.g., motility, invasion, metastasis). Here we identified delta-interacting protein A (DIPA) as the first head domain-specific binding partner and candidate mediator of isoform 1A activity. DIPA colocalizes with AJs in a p120-1A- but not 3A-dependent manner. Moreover, all DIPA family members (Ccdc85a, Ccdc85b/DIPA, and Ccdc85c) interact reciprocally with p120 family members (p120, δ-catenin, p0071, and ARVCF), suggesting significant functional overlap. During zebrafish neural tube development, both knockdown and overexpression of DIPA phenocopy N-cadherin mutations, an effect bearing functional ties to a reported mouse hydrocephalus phenotype associated with Ccdc85c. These studies identify a novel, highly conserved interaction between two protein families that may participate either individually or collectively in N-cadherin-mediated development. © 2014 Markham et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  14. First-order Probabilistic Analysis of the Effects of Heterogeneity on Pore-water Pressure in a Hillslope

    NASA Astrophysics Data System (ADS)

    Cai, J.; Yan, E.; Yeh, T. C. J.

    2015-12-01

    Pore-water pressure in a hillslope is a critical control of its stability. The main objective of this paper is to introduce a first-order moment analysis to investigate the pressure head variability within a hypothetical hillslope, induced by steady rainfall infiltration. This approach accounts for the uncertainties and spatial variation of the hydraulic conductivity, and is based on a first-order Taylor approximation of pressure perturbations calculated by a variably saturated, finite element flow model. Using this approach, the effects of variance (σ2lnKs) and spatial structure anisotropy (λh/λv) of natural logarithm of saturated hydraulic conductivity, and normalized vertical infiltration flux (q/ks) on the hillslope pore-water pressure are evaluated. We found that the responses of pressure head variability (σ2p) are quite different between unsaturated region and saturated region divided by the phreatic surface. Above the phreatic surface, a higher variability in pressure head is obtained from a higher σ2lnKs, a higher λh/λv and a smaller q/ks; while below the phreatic surface, a higher σ2lnKs, a lower λh/λv or a larger q/ks would lead to a higher variability in pressure head, and greater range of fluctuation of the phreatic surface within the hillslope. σ2lnKs has greatest impact on σ2p within the slope and λh/λv has smallest impact. All three variables have greater influence on maximum σ2p within the saturated region below the phreatic surface than that within the unsaturated region above the phreatic surface. The results obtained from this study are useful to understand the influence of hydraulic conductivity variations on slope seepage and stability under different slope conditions and material spatial distributions.

  15. Brush head composition, wear profile, and cleaning efficacy: an assessment of three electric brush heads using in vitro methods.

    PubMed

    Kaiser, Eva; Meyners, Michael; Markgraf, Dirk; Stoerkel, Ulrich; von Koppenfels, Roxana; Adam, Ralf; Soukup, Martin; Wehrbein, Heinrich; Erbe, Christina

    2014-01-01

    The objective of this research was to evaluate a current store brand (SB) brush head for composition/physical characteristics, Wear Index (WI), and cleaning efficacy versus the previous SB brush head refill design (SB control) and the Oral-B Precision Clean brush head (positive control, PC). This research consisted of three parts: 1) Analytical analysis using Fourier Transform Infrared (FT-IR) spectrometry to evaluate the chemical composition of the current SB brush head bristles relative to the SB control. In addition, physical parameters such as bristle count and diameter were determined. 2) Wear Index (WI) investigation to determine the Wear Index scores of in vitro-aged brush heads at four weeks (one month) and 13 weeks (three months) by a trained investigator. To "age" the brush heads, a robot system was used as a new alternative in vitro method to simulate aging by consumer use. 3) Robot testing to determine the cleaning performance of in vitro-aged brush heads, comparing one month-aged current SB brush heads with the SB control (one and three months-aged) and the PC brush heads (three months-aged) in a standardized fashion. 1) FT-IR analysis revealed that the chemical composition of the current and control SB refill brush heads is identical. In terms of physical parameters, the current SB brush head has 12% more bristles and a slightly oval brush head compared to the round brush head of the SB control. 2) Wear Index analysis showed there was no difference in the one month-aged current SB brush head versus the one month-aged SB control (1.67 vs. 1.50, p = 0.65) or versus the three months-aged PC brush head (1.67 vs. 1.50, p = 0.65). The one month-aged current SB brush head demonstrated statistically significantly less wear than the three months-aged SB control (1.67 vs. 2.67, p = 0.01). 3) Analysis of cleaning efficacy shows that the one month-aged current SB brush head had improved cleaning performance over the one month-aged SB control brush head (p < 0.05), despite no statistically significant difference in wear. Both the one month-aged current and control SB brush heads showed statistically significantly lower cleaning performance compared to the three months-aged PC brush heads (p < 0.01). While the current SB brush head showed improved cleaning over the SB control, it demonstrated significantly lower durability and cleaning in comparison to the PC brush head. Dental professionals should be aware of these differences, both in durability and in cleaning performance, when recommending brush heads to their patients.

  16. Spatial orientation and balance control changes induced by altered gravitoinertial force vectors

    NASA Technical Reports Server (NTRS)

    Kaufman, G. D.; Wood, S. J.; Gianna, C. C.; Black, F. O.; Paloski, W. H.

    2001-01-01

    To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

  17. Spatial orientation and balance control changes induced by altered gravitoinertial force vectors.

    PubMed

    Kaufman, G D; Wood, S J; Gianna, C C; Black, F O; Paloski, W H

    2001-04-01

    To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

  18. Miniplate With a Bendable C-Tube Head Allows the Clinician to Alter Biomechanical Advantage in Extremely Complicated Anatomic Structure.

    PubMed

    Seo, Kyung Won; Iskenderoglu, Nur Serife; Hwang, Eui Hwan; Chung, Kyu-Rhim; Kim, Seong-Hun

    2017-05-01

    This article reports C-tube miniplates as a practical temporary anchorage device choice to treat open bite patients with maxillary sinus pneumatization. The C-tube components are titanium anchor plates and monocortical screws that are basically similar to any other miniplate systems, but it has the unique characteristic of the tube head to be malleable. The manipulation of the head part is easy due to the composition of pure titanium. The I-shaped C-tube with 3 holes and T-shaped C-tube miniplates were placed above the apices of maxillary molars as an absolute anchorage system to intrude the posterior maxilla. The bending of the tube heads assisted in reduction of severe open bite patient with maxillary sinus pneumatization. Sinus perforation during placement of skeletal anchorage system weakens stability of the anchorage and further cause complications. Placement of titanium C-tube miniplates allowed reliable skeletal anchorage and avoided maxillary sinus perforation in patients with extreme pneumatizations. Simple bending of C-tube miniplates ensured increased orthodontic intrusion force without having to replace them, and eliminated consequences such as perforation of maxillary sinus, sinusitis, soft tissue irritation, or infection. Anatomic difficulties in the placement of temporary anchorage device can be easily managed by using the bendable C-tube miniplate. It can serve as a great alternative over miniscrews or regular miniplates with reduced risk of sinus perforation and ability to bend the head portion to control orthodontic vectors and forces.

  19. Anti-Hu Antibody Associated Paraneoplastic Cerebellar Degeneration in Head and Neck Cancer.

    PubMed

    Huemer, Florian; Melchardt, Thomas; Tränkenschuh, Wolfgang; Neureiter, Daniel; Moser, Gerhard; Magnes, Teresa; Weiss, Lukas; Schlattau, Alexander; Hufnagl, Clemens; Ricken, Gerda; Höftberger, Romana; Greil, Richard; Egle, Alexander

    2015-12-22

    Paraneoplastic syndromes are most frequently associated with small cell lung carcinoma, hematologic and gynecologic malignancies while reports in head and neck cancer are rare. We present the case of a 60-year old female patient who developed paraneoplastic cerebellar degeneration upon locoregional recurrence of a poorly differentiated spindle cell carcinoma of the nasal cavity and paranasal sinus. The neurological symptoms, especially ataxia, stabilized after resection of tumor recurrence and concomitant chemoradiotherapy whereas anti-Hu-antibodies remained positive. Despite the unfavorable prognosis of paraneoplastic neurological disorders associated with onconeural antibodies, the patient achieved long-standing stabilization of neurological symptoms. We report the first patient with anti-Hu antibodies and paraneoplastic cerebellar degeneration associated with a spindle cell carcinoma of the head and neck. We recommend that evaluation of neurological symptoms in patients with this tumor entity should also include paraneoplastic syndromes as differential diagnoses and suggest early extensive screening for onconeural antibodies.

  20. Aircraft body-axis rotation measurement system

    NASA Technical Reports Server (NTRS)

    Cowdin, K. T. (Inventor)

    1983-01-01

    A two gyro four gimbal attitude sensing system having gimbal lock avoidance is provided with continuous azimuth information, rather than roll information, relative to the magnetic cardinal headings while in near vertical attitudes to allow recovery from vertical on a desired heading. The system is comprised of a means for stabilizing an outer roll gimbal that is common to a vertical gyro and a directional gyro with respect to the aircraft platform which is being angularly displaced about an axis substantially parallel to the outer roll gyro axis. A means is also provided for producing a signal indicative of the magnitude of such displacement as an indication of aircraft heading. Additional means are provided to cause stabilization of the outer roll gimbal whenever the pitch angle of the aircraft passes through a threshold prior to entering vertical flight and destabilization of the outer roll gimbal upon passing through the threshold when departing vertical flight.

  1. The effect of a combined glenoid and Hill-Sachs defect on glenohumeral stability: a biomechanical cadaveric study using 3-dimensional modeling of 142 patients.

    PubMed

    Arciero, Robert A; Parrino, Anthony; Bernhardson, Andrew S; Diaz-Doran, Vilmaris; Obopilwe, Elifho; Cote, Mark P; Golijanin, Petr; Mazzocca, Augustus D; Provencher, Matthew T

    2015-06-01

    Bone loss in anterior glenohumeral instability occurs on both the glenoid and the humerus; however, existing biomechanical studies have evaluated glenoid and humeral head defects in isolation. Thus, little is known about the combined effect of these bony lesions in a clinically relevant model on glenohumeral stability. The purpose of this study was to determine the biomechanical efficacy of a Bankart repair in the setting of bipolar (glenoid and humeral head) bone defects determined via computer-generated 3-dimensional (3D) modeling of 142 patients with recurrent anterior shoulder instability. The null hypothesis was that adding a bipolar bone defect will have no effect on glenohumeral stability after soft tissue Bankart repair. Controlled laboratory study. A total of 142 consecutive patients with recurrent anterior instability were analyzed with 3D computed tomography scans. Two Hill-Sachs lesions were selected on the basis of volumetric size representing the 25th percentile (0.87 cm(3); small) and 50th percentile (1.47 cm(3); medium) and printed in plastic resin with a 3D printer. A total of 21 cadaveric shoulders were evaluated on a custom shoulder-testing device permitting 6 degrees of freedom, and the force required to translate the humeral head anteriorly 10 mm at a rate of 2.0 mm/s with a compressive load of 50 N was determined at 60° of glenohumeral abduction and 60° of external rotation. All Bankart lesions were made sharply from the 2- to 6-o'clock positions for a right shoulder. Subsequent Bankart repair with transosseous tunnels using high-strength suture was performed. Hill-Sachs lesions were made in the cadaver utilizing a plastic mold from the exact replica off the 3D printer. Testing was conducted in the following sequence for each specimen: (1) intact, (2) posterior capsulotomy, (3) Bankart lesion, (4) Bankart repair, (5) Bankart lesion with 2-mm glenoid defect, (6) Bankart repair, (7) Bankart lesion with 2-mm glenoid defect and Hill-Sachs lesion, (8) Bankart repair, (9) Bankart lesion with 4-mm glenoid defect and Hill-Sachs lesion, (10) Bankart repair, (11) Bankart lesion with 6-mm glenoid defect and Hill-Sachs lesion, and (12) Bankart repair. All sequences were used first for a medium Hill-Sachs lesion (10 specimens) and then repeated for a small Hill-Sachs lesion (11 specimens). Three trials were performed in each condition, and the mean value was used for data analysis. A statistically significant and progressive reduction in load to translation was observed after a Bankart lesion was created and with the addition of progressive glenoid defects for each humeral head defect. For medium (50th percentile) Hill-Sachs lesions, there was a 22%, 43%, and 58% reduction in stability with a 2-, 4-, and 6-mm glenoid defect, respectively. For small (25th percentile) Hill-Sachs lesions, there was an 18%, 27%, and 42% reduction in stability with a 2-, 4-, and 6-mm glenoid defect, respectively. With a ≥2-mm glenoid defect, the medium Hill-Sachs group demonstrated significant reduction in translation force after Bankart repair (P < .01), and for the small Hill-Sachs group, a ≥4-mm glenoid defect was required to produce a statistical decrease (P < .01) in reduction force after repair. Combined glenoid and humeral head defects have an additive and negative effect on glenohumeral stability. As little as a 2-mm glenoid defect with a medium-sized Hill-Sachs lesion demonstrated a compromise in soft tissue Bankart repair, while small-sized Hill-Sachs lesions showed compromise of soft tissue repair with ≥4-mm glenoid bone loss. Bipolar bony lesions of the glenoid and humeral head occur frequently together in clinical practice. Surgeons should be aware that the combined defects and glenoid bone loss of 2 to 4 mm or approximately 8% to 15% of the glenoid could compromise Bankart repair and thus may require surgical strategies in addition to traditional Bankart repair alone to optimize stability. © 2015 The Author(s).

  2. A Flight Control System for Small Unmanned Aerial Vehicle

    NASA Astrophysics Data System (ADS)

    Tunik, A. A.; Nadsadnaya, O. I.

    2018-03-01

    The program adaptation of the controller for the flight control system (FCS) of an unmanned aerial vehicle (UAV) is considered. Linearized flight dynamic models depend mainly on the true airspeed of the UAV, which is measured by the onboard air data system. This enables its use for program adaptation of the FCS over the full range of altitudes and velocities, which define the flight operating range. FCS with program adaptation, based on static feedback (SF), is selected. The SF parameters for every sub-range of the true airspeed are determined using the linear matrix inequality approach in the case of discrete systems for synthesis of a suboptimal robust H ∞-controller. The use of the Lagrange interpolation between true airspeed sub-ranges provides continuous adaptation. The efficiency of the proposed approach is shown against an example of the heading stabilization system.

  3. Composting on Mars or the Moon: II. Temperature feedback control with top-wise introduction of waste material and air

    NASA Technical Reports Server (NTRS)

    Finstein, M. S.; Hogan, J. A.; Sager, J. C.; Cowan, R. M.; Strom, P. F.; Janes, H. W. (Principal Investigator)

    1999-01-01

    Whereas Earth-based composting reactors that effectively control the process are batch operations with bottom-to-top airflow, in extraterrestrial application both the fresh waste and the air need to be introduced from above. Stabilized compost and used air would exit below. This materials flow pattern permits the addition of waste whenever generated, obviating the need for multiple reactors, and the incorporation of a commode in the lid. Top loading in turn dictates top-down aeration, so that the most actively decomposing material (greatest need for heat removal and O2 replenishment) is first encountered. This novel material and aeration pattern was tested in conjunction with temperature feedback process control. Reactor characteristics were: working, volume, 0.15 m3; charge, 2 kg dry biomass per day (comparable to a 3-4 person self-sufficient bioregenerative habitat); retention time, 7 days. Judging from temperature profile, O2 level, air usage, pressure head loss, moisture, and odor, the system was effectively controlled over a 35-day period. Dry matter disappearance averaged 25% (10-42%). The compost product was substantially, though not completely, stabilized. This demonstrates the compatibility of top-wise introduction of waste and air with temperature feedback process control.

  4. Composting on Mars or the Moon: II. Temperature feedback control with top-wise introduction of waste material and air.

    PubMed

    Finstein, M S; Hogan, J A; Sager, J C; Cowan, R M; Strom, P F

    1999-01-01

    Whereas Earth-based composting reactors that effectively control the process are batch operations with bottom-to-top airflow, in extraterrestrial application both the fresh waste and the air need to be introduced from above. Stabilized compost and used air would exit below. This materials flow pattern permits the addition of waste whenever generated, obviating the need for multiple reactors, and the incorporation of a commode in the lid. Top loading in turn dictates top-down aeration, so that the most actively decomposing material (greatest need for heat removal and O2 replenishment) is first encountered. This novel material and aeration pattern was tested in conjunction with temperature feedback process control. Reactor characteristics were: working, volume, 0.15 m3; charge, 2 kg dry biomass per day (comparable to a 3-4 person self-sufficient bioregenerative habitat); retention time, 7 days. Judging from temperature profile, O2 level, air usage, pressure head loss, moisture, and odor, the system was effectively controlled over a 35-day period. Dry matter disappearance averaged 25% (10-42%). The compost product was substantially, though not completely, stabilized. This demonstrates the compatibility of top-wise introduction of waste and air with temperature feedback process control.

  5. Environmental Data Collection Using Autonomous Wave Gliders

    DTIC Science & Technology

    2014-12-01

    Observing System IMU Inertial Measurement Unit LRI Liquid Robotics, Inc. MASFlux Marine-Air-Sea-Flux METOC meteorological and oceanographic...position, velocity, heading, pitch, roll , and six-axis acceleration rates (Figure 11). A separate temperature probe also provides sea surface...Position, Velocity, and Magnetic declination True North Revolution Technologies GS Gyro Stabilized Electronic Compass Heading, Pitch, and Roll

  6. VSTOL Systems Research Aircraft (VSRA) Harrier

    NASA Technical Reports Server (NTRS)

    1994-01-01

    NASA's Ames Research Center has developed and is testing a new integrated flight and propulsion control system that will help pilots land aircraft in adverse weather conditions and in small confined ares (such as, on a small ship or flight deck). The system is being tested in the V/STOL (Vertical/Short Takeoff and Landing) Systems research Aircraft (VSRA), which is a modified version of the U.S. Marine Corps's AV-8B Harrier jet fighter, which can take off and land vertically. The new automated flight control system features both head-up and panel-mounted computer displays and also automatically integrates control of the aircraft's thrust and thrust vector control, thereby reducing the pilot's workload and help stabilize the aircraft for landing. Visiting pilots will be encouraged to test the new system and provide formal evaluation flights data and feedback. An actual flight test and the display panel of control system are shown in this video.

  7. Gas cushion control of OVJP print head position

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forrest, Stephen R

    An OVJP apparatus and method for applying organic vapor or other flowable material to a substrate using a printing head mechanism in which the print head spacing from the substrate is controllable using a cushion of air or other gas applied between the print head and substrate. The print head is mounted for translational movement towards and away from the substrate and is biased toward the substrate by springs or other means. A gas cushion feed assembly supplies a gas under pressure between the print head and substrate which opposes the biasing of the print head toward the substrate somore » as to form a space between the print head and substrate. By controlling the pressure of gas supplied, the print head separation from the substrate can be precisely controlled.« less

  8. Hybridization among Arctic white-headed gulls (Larus spp.) obscures the genetic legacy of the Pleistocene

    USGS Publications Warehouse

    Sonsthagen, Sarah A.; Chesser, R. Terry; Bell, Douglas A.; Dove, Carla J.

    2012-01-01

    We studied the influence of glacial oscillations on the genetic structure of seven species of white-headed gull that breed at high latitudes (Larus argentatus, L. canus, L. glaucescens, L. glaucoides, L. hyperboreus, L. schistisagus, and L. thayeri). We evaluated localities hypothesized as ice-free areas or glacial refugia in other Arctic vertebrates using molecular data from 11 microsatellite loci, mitochondrial DNA (mtDNA) control region, and six nuclear introns for 32 populations across the Holarctic. Moderate levels of genetic structure were observed for microsatellites (FST= 0.129), introns (ΦST= 0.185), and mtDNA control region (ΦST= 0.461), with among-group variation maximized when populations were grouped based on subspecific classification. Two haplotype and at least two allele groups were observed across all loci. However, no haplotype/allele group was composed solely of individuals of a single species, a pattern consistent with recent divergence. Furthermore, northernmost populations were not well differentiated and among-group variation was maximized when L. argentatus and L. hyberboreus populations were grouped by locality rather than species, indicating recent hybridization. Four populations are located in putative Pleistocene glacial refugia and had larger t estimates than the other 28 populations. However, we were unable to substantiate these putative refugia using coalescent theory, as all populations had genetic signatures of stability based on mtDNA. The extent of haplotype and allele sharing among Arctic white-headed gull species is noteworthy. Studies of other Arctic taxa have generally revealed species-specific clusters as well as genetic structure within species, usually correlated with geography. Aspects of white-headed gull behavioral biology, such as colonization ability and propensity to hybridize, as well as their recent evolutionary history, have likely played a large role in the limited genetic structure observed.

  9. Comparison of isometric cervical flexor and isometric cervical extensor system exercises on patients with neuromuscular imbalance and cervical crossed syndrome associated forward head posture.

    PubMed

    Lee, Jaejin; Kim, Dohyeon; Yu, Kyunghoon; Cho, Youngki; You, Joshua H

    2018-01-01

    Isometric cervical flexor system exercise (ICF) and isometric cervical extensor system exercise (ICE) are cervical stabilization techniques that have been used to restore cervical crossed syndrome (CCS)-associated forward head posture. However, the therapeutic effects and underlying motor control mechanisms remain elusive. The purpose of present study was investigating the concurrent therapeutic effects of ICF and ICE on muscle size, muscle imbalance ratio, and muscle recruitment sequence using ultrasound imaging and electromyography. A total of 18 participants (7 females; age=24±4.0 years) with CCS associated with forward head posture underwent ICF and ICE. Paired t-test analysis was used for statistical analysis. Paired t-test analysis showed that sternocleidomastoid thickness was greater during ICF than ICE. Similarly, cross-sectional area and horizontal thickness of the longus colli were greater during ICE than ICF. The upper trapezius/lower trapezius muscle imbalance ratio and the pectoralis major/lower trapezius muscle imbalance ratio were significantly decreased during the application of ICE compared to ICF. These results provide compelling, mechanistic evidence as to how ICE is more beneficial for the restoration of neuromuscular imbalance than ICF in individuals with CCS.

  10. Body temperature depression and peripheral heat loss accompany the metabolic and ventilatory responses to hypoxia in low and high altitude birds.

    PubMed

    Scott, Graham R; Cadena, Viviana; Tattersall, Glenn J; Milsom, William K

    2008-04-01

    The objectives of this study were to compare the thermoregulatory, metabolic and ventilatory responses to hypoxia of the high altitude bar-headed goose with low altitude waterfowl. All birds were found to reduce body temperature (T(b)) during hypoxia, by up to 1-1.5 degrees C in severe hypoxia. During prolonged hypoxia, T(b) stabilized at a new lower temperature. A regulated increase in heat loss contributed to T(b) depression as reflected by increases in bill surface temperatures (up to 5 degrees C) during hypoxia. Bill warming required peripheral chemoreceptor inputs, since vagotomy abolished this response to hypoxia. T(b) depression could still occur without bill warming, however, because vagotomized birds reduced T(b) as much as intact birds. Compared to both greylag geese and pekin ducks, bar-headed geese required more severe hypoxia to initiate T(b) depression and heat loss from the bill. However, when T(b) depression or bill warming were expressed relative to arterial O(2) concentration (rather than inspired O(2)) all species were similar; this suggests that enhanced O(2) loading, rather than differences in thermoregulatory control centres, reduces T(b) depression during hypoxia in bar-headed geese. Correspondingly, bar-headed geese maintained higher rates of metabolism during severe hypoxia (7% inspired O(2)), but this was only partly due to differences in T(b). Time domains of the hypoxic ventilatory response also appeared to differ between bar-headed geese and low altitude species. Overall, our results suggest that birds can adjust peripheral heat dissipation to facilitate T(b) depression during hypoxia, and that bar-headed geese minimize T(b) and metabolic depression as a result of evolutionary adaptations that enhance O(2) transport.

  11. Effects of dynamic head tilts on sensory organization test performance: a comparison between college-age athletes and nonathletes.

    PubMed

    Clark, Sean; Iltis, Peter W

    2008-05-01

    Controlled laboratory study. To compare postural performance measures of athletes with those of nonathletes when completing the standard Sensory Organization Test (SOT) and a modified SOT that included dynamic head tilts (DHT-SOT). Authors of recently published research have suggested that modifications to the SOT protocol (eg, introduction of pitch and roll head tilts) may enhance the test's sensitivity when assessing postural stability in individuals with higher balance capabilities or with well-compensated sensory deficits. Nineteen athletes and 19 nonathletes (group) completed both the SOT and DHT-SOT (protocol). During the SOT, participants stood upright as steadily as possible for 20 seconds during each of 6 different sensory conditions. As a variation of the SOT, the DHT-SOT incorporated active pitch and roll head tilts into the SOT protocol. Four 2-way mixed-model analyses of variance (with protocol as the repeated factor) were performed to determine if the composite equilibrium score or the visual, vestibular, or somatosensory ratio scores differed between the 2 groups across the 2 testing protocols. Significant group-by-protocol interaction effects were present for both the composite equilibrium score and visual ratio. Follow-up simple main-effects analyses indicated that these measures did not differ between groups for the SOT protocol but were significantly different on the DHT-SOT. The addition of dynamic head tilts to the SOT protocol resulted in subtle differences in balance function between athletes and nonathletes. Athletes demonstrated an increased ability to adapt to sensory disruptions during the DHT-SOT. Therapists should consider including active pitch and roll head tilts to the SOT when evaluating individuals with higher balance function or to detect subtle deficits in balance function. Diagnosis, level 3b.

  12. Adapted head- and eye-movement responses to added-head inertia

    NASA Technical Reports Server (NTRS)

    Gauthier, G. M.; Martin, B. J.; Stark, L. W.

    1986-01-01

    Adaptation to inertia added to the head was studied in men by mounting masses on a rigidly attached helmet until two- to ten-fold increases of inertia were produced, while an overhead suspension compensated for the weights. The observed changes in the eye and head movement coordination included increased head movement latencies, as well as changes in the eye movement amplitude, and later stabilizing alternate contractions of the neck muscles. Oscillopsia, or continual displacement or instability of the visual world, which is a symptom of a breakdown of space constancy, was prominent and consistent in the perceptual reports of the subjects. Although adaptation resulting from adding inertia to the head occurred much faster than that induced by adding prisms or lenses, it has similar perceptual and motor components that may be objectively studied in detail.

  13. Differences in gaze anticipation for locomotion with and without vision

    PubMed Central

    Authié, Colas N.; Hilt, Pauline M.; N'Guyen, Steve; Berthoz, Alain; Bennequin, Daniel

    2015-01-01

    Previous experimental studies have shown a spontaneous anticipation of locomotor trajectory by the head and gaze direction during human locomotion. This anticipatory behavior could serve several functions: an optimal selection of visual information, for instance through landmarks and optic flow, as well as trajectory planning and motor control. This would imply that anticipation remains in darkness but with different characteristics. We asked 10 participants to walk along two predefined complex trajectories (limaçon and figure eight) without any cue on the trajectory to follow. Two visual conditions were used: (i) in light and (ii) in complete darkness with eyes open. The whole body kinematics were recorded by motion capture, along with the participant's right eye movements. We showed that in darkness and in light, horizontal gaze anticipates the orientation of the head which itself anticipates the trajectory direction. However, the horizontal angular anticipation decreases by a half in darkness for both gaze and head. In both visual conditions we observed an eye nystagmus with similar properties (frequency and amplitude). The main difference comes from the fact that in light, there is a shift of the orientations of the eye nystagmus and the head in the direction of the trajectory. These results suggest that a fundamental function of gaze is to represent self motion, stabilize the perception of space during locomotion, and to simulate the future trajectory, regardless of the vision condition. PMID:26106313

  14. Low-temperature technique for thick film resist stabilization and curing

    NASA Astrophysics Data System (ADS)

    Minter, Jason P.; Wong, Selmer S.; Marlowe, Trey; Ross, Matthew F.; Narcy, Mark E.; Livesay, William R.

    1999-06-01

    For a range of thick film photoresist applications, including MeV ion implant processing, thin film head manufacturing, and microelectromechanical systems processing, there is a need for a low-temperature method for resist stabilization and curing. Traditional methods of stabilizing or curing resist films have relied on thermal cycling, which may not be desirable due to device temperature limitations or thermally-induced distortion of the resist features.

  15. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    NASA Astrophysics Data System (ADS)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  16. Genome Stability Pathways in Head and Neck Cancers

    PubMed Central

    O'Byrne, Kenneth J.; Panizza, Benedict; Richard, Derek J.

    2013-01-01

    Genomic instability underlies the transformation of host cells toward malignancy, promotes development of invasion and metastasis and shapes the response of established cancer to treatment. In this review, we discuss recent advances in our understanding of genomic stability in squamous cell carcinoma of the head and neck (HNSCC), with an emphasis on DNA repair pathways. HNSCC is characterized by distinct profiles in genome stability between similarly staged cancers that are reflected in risk, treatment response and outcomes. Defective DNA repair generates chromosomal derangement that can cause subsequent alterations in gene expression, and is a hallmark of progression toward carcinoma. Variable functionality of an increasing spectrum of repair gene polymorphisms is associated with increased cancer risk, while aetiological factors such as human papillomavirus, tobacco and alcohol induce significantly different behaviour in induced malignancy, underpinned by differences in genomic stability. Targeted inhibition of signalling receptors has proven to be a clinically-validated therapy, and protein expression of other DNA repair and signalling molecules associated with cancer behaviour could potentially provide a more refined clinical model for prognosis and treatment prediction. Development and expansion of current genomic stability models is furthering our understanding of HNSCC pathophysiology and uncovering new, promising treatment strategies. PMID:24364026

  17. Eye size and visual acuity influence vestibular anatomy in mammals.

    PubMed

    Kemp, Addison D; Christopher Kirk, E

    2014-04-01

    The semicircular canals of the inner ear detect head rotations and trigger compensatory movements that stabilize gaze and help maintain visual fixation. Mammals with large eyes and high visual acuity require precise gaze stabilization mechanisms because they experience diminished visual functionality at low thresholds of uncompensated motion. Because semicircular canal radius of curvature is a primary determinant of canal sensitivity, species with large canal radii are expected to be capable of more precise gaze stabilization than species with small canal radii. Here, we examine the relationship between mean semicircular canal radius of curvature, eye size, and visual acuity in a large sample of mammals. Our results demonstrate that eye size and visual acuity both explain a significant proportion of the variance in mean canal radius of curvature after statistically controlling for the effects of body mass and phylogeny. These findings suggest that variation in mean semicircular canal radius of curvature among mammals is partly the result of selection for improved gaze stabilization in species with large eyes and acute vision. Our results also provide a possible functional explanation for the small semicircular canal radii of fossorial mammals and plesiadapiforms. Copyright © 2014 Wiley Periodicals, Inc.

  18. [Nystagmus].

    PubMed

    Jutila, Topi; Hirvonen, Timo P

    2013-01-01

    Physiological nystagmus stabilizes gaze during head movements and pathological nystagmus reflects a disorder of the vestibulo-ocular reflex (VOR). Pathological nystagmus appears or strengthens usually during change in head position. Therefore, dizziness or nystagmus associated with head movements is not specific to benign paroxysmal positional vertigo unless it is verified in specific positional test. Peripheral nystagmus decelerates during visual fixation, accelerates when gaze is turned towards the fast phase, does not change direction, and is usually composed of several directional components unlike central nystagmus. The velocity and frequency of the slow phase of nystagmus can be measured with electronystagmography or video-oculography.

  19. Cervical helical axis characteristics and its center of rotation during active head and upper arm movements-comparisons of whiplash-associated disorders, non-specific neck pain and asymptomatic individuals.

    PubMed

    Grip, Helena; Sundelin, Gunnevi; Gerdle, Björn; Stefan Karlsson, J

    2008-09-18

    The helical axis model can be used to describe translation and rotation of spine segments. The aim of this study was to investigate the cervical helical axis and its center of rotation during fast head movements (side rotation and flexion/extension) and ball catching in patients with non-specific neck pain or pain due to whiplash injury as compared with matched controls. The aim was also to investigate correlations with neck pain intensity. A finite helical axis model with a time-varying window was used. The intersection point of the axis during different movement conditions was calculated. A repeated-measures ANOVA model was used to investigate the cervical helical axis and its rotation center for consecutive levels of 15 degrees during head movement. Irregularities in axis movement were derived using a zero-crossing approach. In addition, head, arm and upper body range of motion and velocity were observed. A general increase of axis irregularity that correlated to pain intensity was observed in the whiplash group. The rotation center was superiorly displaced in the non-specific neck pain group during side rotation, with the same tendency for the whiplash group. During ball catching, an anterior displacement (and a tendency to an inferior displacement) of the center of rotation and slower and more restricted upper body movements implied a changed movement strategy in neck pain patients, possibly as an attempt to stabilize the cervical spine during head movement.

  20. Portable long trace profiler: Concept and solution

    NASA Astrophysics Data System (ADS)

    Qian, Shinan; Takacs, Peter; Sostero, Giovanni; Cocco, Daniele

    2001-08-01

    Since the early development of the penta-prism long trace profiler (LTP) and the in situ LTP, and following the completion of the first in situ distortion profile measurements at Sincrotrone Trieste (ELETTRA) in Italy in 1995, a concept was developed for a compact, portable LTP with the following characteristics: easily installed on synchrotron radiation beam lines, easily carried to different laboratories around the world for measurements and calibration, convenient for use in evaluating the LTP as an in-process tool in the optical workshop, and convenient for use in temporarily installation as required by other special applications. The initial design of a compact LTP optical head was made at ELETTRA in 1995. Since 1997 further efforts to reduce the optical head size and weight, and to improve measurement stability have been made at Brookhaven National Laboratory. This article introduces the following solutions and accomplishments for the portable LTP: (1) a new design for a compact and very stable optical head, (2) the use of a small detector connected to a laptop computer directly via an enhanced parallel port, and there is no extra frame grabber interface and control box, (3) a customized small mechanical slide that uses a compact motor with a connector-sized motor controller, and (4) the use of a laptop computer system. These solutions make the portable LTP able to be packed into two laptop-size cases: one for the computer and one for the rest of the system.

  1. An ex vivo model in human femoral heads for histopathological study and resonance frequency analysis of dental implant primary stability.

    PubMed

    Hernández-Cortés, Pedro; Monje, Alberto; Galindo-Moreno, Pablo; Catena, Andrés; Ortega-Oller, Inmaculada; Salas-Pérez, José; Mesa, Francisco; Gómez-Sánchez, Rafael; Aguilar, Mariano; Aguilar, David; O'Valle, Francisco

    2014-01-01

    This study was designed to explore relationships of resonance frequency analysis (RFA)-assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) (n = 7) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) (n = 10). Sixty 4.5 × 13 mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) (P < 0.001), but not of the implants (P = 0.455) or of the interaction of the two factors (P = 0.848). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified (50.33 ± 2.92) heads than in fresh (66.93 ± 1.10) or fixated (70.77 ± 1.32) heads (both P < 0.001). The ISQ score (fresh) was significantly higher for those in OA (73.52 ± 1.92) versus OP (67.13 ± 1.09) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results (P > 0.5 in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both P > 0.08). Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies.

  2. Using EMG to anticipate head motion for virtual-environment applications

    NASA Technical Reports Server (NTRS)

    Barniv, Yair; Aguilar, Mario; Hasanbelliu, Erion

    2005-01-01

    In virtual environment (VE) applications, where virtual objects are presented in a see-through head-mounted display, virtual images must be continuously stabilized in space in response to user's head motion. Time delays in head-motion compensation cause virtual objects to "swim" around instead of being stable in space which results in misalignment errors when overlaying virtual and real objects. Visual update delays are a critical technical obstacle for implementing head-mounted displays in applications such as battlefield simulation/training, telerobotics, and telemedicine. Head motion is currently measurable by a head-mounted 6-degrees-of-freedom inertial measurement unit. However, even given this information, overall VE-system latencies cannot be reduced under about 25 ms. We present a novel approach to eliminating latencies, which is premised on the fact that myoelectric signals from a muscle precede its exertion of force, thereby limb or head acceleration. We thus suggest utilizing neck-muscles' myoelectric signals to anticipate head motion. We trained a neural network to map such signals onto equivalent time-advanced inertial outputs. The resulting network can achieve time advances of up to 70 ms.

  3. Using EMG to anticipate head motion for virtual-environment applications.

    PubMed

    Barniv, Yair; Aguilar, Mario; Hasanbelliu, Erion

    2005-06-01

    In virtual environment (VE) applications, where virtual objects are presented in a see-through head-mounted display, virtual images must be continuously stabilized in space in response to user's head motion. Time delays in head-motion compensation cause virtual objects to "swim" around instead of being stable in space which results in misalignment errors when overlaying virtual and real objects. Visual update delays are a critical technical obstacle for implementing head-mounted displays in applications such as battlefield simulation/training, telerobotics, and telemedicine. Head motion is currently measurable by a head-mounted 6-degrees-of-freedom inertial measurement unit. However, even given this information, overall VE-system latencies cannot be reduced under about 25 ms. We present a novel approach to eliminating latencies, which is premised on the fact that myoelectric signals from a muscle precede its exertion of force, thereby limb or head acceleration. We thus suggest utilizing neck-muscles' myoelectric signals to anticipate head motion. We trained a neural network to map such signals onto equivalent time-advanced inertial outputs. The resulting network can achieve time advances of up to 70 ms.

  4. Efficient Dual Head Nd:YAG 100mJ Oscillator for Remote Sensing

    NASA Technical Reports Server (NTRS)

    Coyle, Donald B.; Stysley, Paul R.; Kay, Richard b.; Poulios, Demetrios

    2007-01-01

    A diode pumped, Nd:YAG laser producing 100 mJ Q-switched pulses and employing a dual-pump head scheme in an unstable resonator configuration is described. Each head contains a side pumped zig-zag slab and four 6-bar QCW 808 nm diodes arrays which are de-rated 23%. Denoting 'z' as the lasing axis, the pump directions were along the x-axis in one head and the y-axis in the other, producing a circularized thermal lens, more typical in laser rod-based cavities. The dual head design's effective thermal lens is now corrected with a proper HR mirror curvature selection. This laser has demonstrated over 100 mJ output with high optical efficiency (24%), good TEM(sub 00) beam quality, and high pointing stability.

  5. Keyboard before Head Tracking Depresses User Success in Remote Camera Control

    NASA Astrophysics Data System (ADS)

    Zhu, Dingyun; Gedeon, Tom; Taylor, Ken

    In remote mining, operators of complex machinery have more tasks or devices to control than they have hands. For example, operating a rock breaker requires two handed joystick control to position and fire the jackhammer, leaving the camera control to either automatic control or require the operator to switch between controls. We modelled such a teleoperated setting by performing experiments using a simple physical game analogue, being a half size table soccer game with two handles. The complex camera angles of the mining application were modelled by obscuring the direct view of the play area and the use of a Pan-Tilt-Zoom (PTZ) camera. The camera control was via either a keyboard or via head tracking using two different sets of head gestures called “head motion” and “head flicking” for turning camera motion on/off. Our results show that the head motion control was able to provide a comparable performance to using a keyboard, while head flicking was significantly worse. In addition, the sequence of use of the three control methods is highly significant. It appears that use of the keyboard first depresses successful use of the head tracking methods, with significantly better results when one of the head tracking methods was used first. Analysis of the qualitative survey data collected supports that the worst (by performance) method was disliked by participants. Surprisingly, use of that worst method as the first control method significantly enhanced performance using the other two control methods.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scheinker, Alexander

    Here, we study control of the angular-velocity actuated nonholonomic unicycle, via a simple, bounded extremum seeking controller which is robust to external disturbances and measurement noise. The vehicle performs source seeking despite not having any position information about itself or the source, able only to sense a noise corrupted scalar value whose extremum coincides with the unknown source location. In order to control the angular velocity, rather than the angular heading directly, a controller is developed such that the closed loop system exhibits multiple time scales and requires an analysis approach expanding the previous work of Kurzweil, Jarnik, Sussmann, andmore » Liu, utilizing weak limits. We provide analytic proof of stability and demonstrate how this simple scheme can be extended to include position-independent source seeking, tracking, and collision avoidance of groups on autonomous vehicles in GPS-denied environments, based only on a measure of distance to an obstacle, which is an especially important feature for an autonomous agent.« less

  7. In Vitro versus In Vivo Phase Instability of Zirconia-Toughened Alumina Femoral Heads: A Critical Comparative Assessment

    PubMed Central

    Pezzotti, Giuseppe; Affatato, Saverio; Rondinella, Alfredo; Yorifuji, Makiko; Marin, Elia; Zhu, Wenliang; McEntire, Bryan; Bal, Sonny B.; Yamamoto, Kengo

    2017-01-01

    A clear discrepancy between predicted in vitro and actual in vivo surface phase stability of BIOLOX®delta zirconia-toughened alumina (ZTA) femoral heads has been demonstrated by several independent research groups. Data from retrievals challenge the validity of the standard method currently utilized in evaluating surface stability and raise a series of important questions: (1) Why do in vitro hydrothermal aging treatments conspicuously fail to model actual results from the in vivo environment? (2) What is the preponderant microscopic phenomenon triggering the accelerated transformation in vivo? (3) Ultimately, what revisions of the current in vitro standard are needed in order to obtain consistent predictions of ZTA transformation kinetics in vivo? Reported in this paper is a new in toto method for visualizing the surface stability of femoral heads. It is based on CAD-assisted Raman spectroscopy to quantitatively assess the phase transformation observed in ZTA retrievals. Using a series of independent analytical probes, an evaluation of the microscopic mechanisms responsible for the polymorphic transformation is also provided. An outline is given of the possible ways in which the current hydrothermal simulation standard for artificial joints can be improved in an attempt to reduce the gap between in vitro simulation and reality. PMID:28772828

  8. Micro-drive and headgear for chronic implant and recovery of optoelectronic probes.

    PubMed

    Chung, Jinho; Sharif, Farnaz; Jung, Dajung; Kim, Soyoun; Royer, Sebastien

    2017-06-05

    Silicon probes are multisite electrodes used for the electrophysiological recording of large neuronal ensembles. Optoelectronic probes (OEPs) are recent upgrades that allow, in parallel, the delivery of local optical stimuli. The procedures to use these delicate electrodes for chronic experiments in mice are still underdeveloped and typically assume one-time uses. Here, we developed a micro-drive, a support for OEPs optical fibers, and a hat enclosure, which fabrications consist in fitting and fastening together plastic parts made with 3D printers. Excluding two parts, all components and electrodes are relatively simple to recover after the experiments, via the loosening of screws. To prevent the plugging of OEPs laser sources from altering the stability of recordings, the OEPs fibers can be transiently anchored to the hat via the tightening of screws. We test the stability of recordings in the mouse hippocampus under three different conditions: acute head-fixed, chronic head-fixed, and chronic freely moving. Drift in spike waveforms is significantly smaller in chronic compared to acute conditions, with the plugging/unplugging of head-stage and fiber connectors not affecting much the recording stability. Overall, these tools generate stable recordings of place cell in chronic conditions, and make the recovery and reuse of electrode packages relatively simple.

  9. A LONGITUDINAL, PERSON-CENTERED ANALYSIS OF EARLY HEAD START MOTHERS' PARENTING.

    PubMed

    Paschall, Katherine W; Mastergeorge, Ann M

    2018-01-01

    This study used a person-centered approach to examine stability and change in parenting typologies across early childhood. Profiles were associated within and across time with contextual covariates, including demographic characteristics, risk factors, and Early Head Start participation. Participants were drawn from the Early Head Start Research and Evaluation Project (N = 2, 876). Parenting profiles were identified based on observed parenting dimensions at 14, 24, and 36 months, and pre-Kindergarten (pre-K). Results suggested a four-profile solution at each time point: Supportive, Lukewarm (14 & 24 months)/Sufficient (36 months and pre-K), Harsh, and Detached. Supportive was the largest, most stable, and most likely transitioned into profile while Harsh and Detached represented rare profiles with moderate to low membership stability across time. Depression and family conflict emerged as important correlates of unsupportive parenting profiles both within and across time. Findings are discussed in terms of their relevance for both policy and implementation practices for low-income mothers with young children. © 2017 Michigan Association for Infant Mental Health.

  10. Continuous-wave EPR at 275 GHz: Application to high-spin Fe 3+ systems

    NASA Astrophysics Data System (ADS)

    Mathies, G.; Blok, H.; Disselhorst, J. A. J. M.; Gast, P.; van der Meer, H.; Miedema, D. M.; Almeida, R. M.; Moura, J. J. G.; Hagen, W. R.; Groenen, E. J. J.

    2011-05-01

    The 275 GHz electron-paramagnetic-resonance spectrometer we reported on in 2004 has been equipped with a new probe head, which contains a cavity especially designed for operation in continuous-wave mode. The sensitivity and signal stability that is achieved with this new probe head is illustrated with 275 GHz continuous-wave spectra of a 1 mM frozen solution of the complex Fe(III)-ethylenediamine tetra-acetic acid and of 10 mM frozen solutions of the protein rubredoxin, which contains Fe 3+ in its active site, from three different organisms. The high quality of the spectra of the rubredoxins allows the determination of the zero-field-splitting parameters with an accuracy of 0.5 GHz. The success of our approach results partially from the enhanced absolute sensitivity, which can be reached using a single-mode cavity. At least as important is the signal stability that we were able to achieve with the new probe head.

  11. Control of membrane permeability in air-stable droplet interface bilayers

    DOE PAGES

    Mruetusatorn, Prachya; Polizos, Georgios; Datskos, Panos G.; ...

    2015-03-19

    Air-stable droplet interface bilayers (airDIBs) on oil-infused surfaces are versatile model membranes for synthetic biology applications, including biosensing of airborne species. However, air-DIBs are subject to evaporation, which can, over time, destabilize them and reduce their useful lifetime compared to traditional DIBs that are fully submerged in oil. Here, we show that lifetimes of air-DIBs can be extended by as much as an order of magnitude by maintaining them at a temperature just above the dew point. We find that raising the temperature from near the dew point (7 C at 38.5 % relative humidity) to room temperature results inmore » loss of water molecules of hydration from the polar head groups of the lipid bilayer membrane due to evaporation in an irreversible process that increases the overall entropy of the system. This dehydration transition affects primarily the bilayer resistance, by increasing ion permeability through the increasingly disordered polar head group region of the bilayer. Temperature and/or relative humidity are conveniently tunable parameters for controlling the stability and composition of air-DIBs membranes, while still allowing for operation in ambient environments.« less

  12. Trunk involvement in performing upper extremity activities while seated in neurological patients with a flaccid trunk - A review.

    PubMed

    Peeters, Laura H C; de Groot, Imelda J M; Geurts, Alexander C H

    2018-05-01

    Trunk control is essential during seated activities. The trunk interacts with the upper extremities (UE) and head by being part of a kinematic chain and by providing a stable basis. When trunk control becomes impaired, it may have consequences for the execution of UE tasks. To review trunk involvement in body movement and stability when performing seated activities and its relation with UE and head movements in neurological patients with a flaccid trunk, with a focus on childhood and development with age. A search using PubMed was conducted and 32 out of 188 potentially eligible articles were included. Patients with a flaccid trunk (e.g. with spinal cord injury or cerebral palsy) tend to involve the trunk earlier while reaching than healthy persons. Different balance strategies are observed in different types of patients, like using the contralateral arm as counterweight, eliminating degrees of freedom, or reducing movement speed. The key role of the trunk in performing activities should be kept in mind when developing interventions to improve seated task performance in neurological patients with a flaccid trunk. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Head-Mounted and Head-Up Display Glossary

    NASA Technical Reports Server (NTRS)

    Newman, Richard L.; Allen, J. Edwin W. (Technical Monitor)

    1997-01-01

    One of the problems in head-up and helmet-mounted display (HMD) literature has been a lack of standardization of words and abbreviations. Several different words have been used for the same concept; for example, flight path angle, flight path marker, velocity vector, and total velocity vector all refer to the same thing. In other cases, the same term has been used with two different meanings, such as binocular field-of-view which means the field-of-view visible to both left and right eyes according to some or the field-of-view visible to either the left or right eye or both according to others. Many of the terms used in HMD studies have not been well-defined. We need to have a common language to ensure that system descriptions are communicated. As an example, the term 'stabilized' has been widely used with two meanings. 'Roll-stabilized' has been used to mean a symbol which rotates to indicate the roll or bank of the aircraft. 'World-stabilized' and 'head-stabilized' have both been used to indicate symbols which move to remain fixed with respect to external objects. HMDs present unique symbology problems not found in HUDs. Foremost among these is the issue of maintaining spatial orientation of the symbols. All previous flight displays, round dial instruments, HDDs, and HUDs have been fixed in the cockpit. With the HMD, the flight display can move through a large angle. The coordinates use in transforming from the real-world to the aircraft to the HMD have not been consistently defined. This glossary contains terms relating to optics and vision, displays, and flight information, weapons and aircraft systems. Some definitions, such as Navigation Display, have been added to clarify the definitions for Primary Flight Display and Primary Flight Reference. A list of HUD/HMD related abbreviations is also included.

  14. Helmet Fit and Cervical Spine Motion in Collegiate Men's Lacrosse Athletes Secured to a Spine Board

    PubMed Central

    Petschauer, Meredith A.; Schmitz, Randy; Gill, Diane L.

    2010-01-01

    Abstract Context: Proper management of cervical spine injuries in men's lacrosse players depends in part upon the ability of the helmet to immobilize the head. Objective: To determine if properly and improperly fitted lacrosse helmets provide adequate stabilization of the head in the spine-boarded athlete. Design: Crossover study. Setting: Sports medicine research laboratory. Patients or Other Participants: Eighteen healthy collegiate men's lacrosse players. Intervention(s): Participants were asked to move their heads through 3 planes of motion after being secured to a spine board under 3 helmet conditions. Main Outcome Measure(s): Change in range of motion in the cervical spine was calculated for the sagittal, frontal, and transverse planes for both head-to-thorax and helmet-to-thorax range of motion in all 3 helmet conditions (properly fitted, improperly fitted, and no helmet). Results: Head-to-thorax range of motion with the properly fitted and improperly fitted helmets was greater than in the no-helmet condition (P < .0001). In the sagittal plane, range of motion was greater with the improperly fitted helmet than with the properly fitted helmet. No difference was observed in helmet-to-thorax range of motion between properly and improperly fitted helmet conditions. Head-to-thorax range of motion was greater than helmet-to-thorax range of motion in all 3 planes (P < .0001). Conclusions: Cervical spine motion was minimized the most in the no-helmet condition, indicating that in lacrosse players, unlike football players, the helmet may need to be removed before stabilization. PMID:20446833

  15. Integrated head package for top mounted nuclear instrumentation

    DOEpatents

    Malandra, Louis J.; Hornak, Leonard P.; Meuschke, Robert E.

    1993-01-01

    A nuclear reactor such as a pressurized water reactor has an integrated head package providing structural support and increasing shielding leading toward the vessel head. A reactor vessel head engages the reactor vessel, and a control rod guide mechanism over the vessel head raises and lowers control rods in certain of the thimble tubes, traversing penetrations in the reactor vessel head, and being coupled to the control rods. An instrumentation tube structure includes instrumentation tubes with sensors movable into certain thimble tubes disposed in the fuel assemblies. Couplings for the sensors also traverse penetrations in the reactor vessel head. A shroud is attached over the reactor vessel head and encloses the control rod guide mechanism and at least a portion of the instrumentation tubes when retracted. The shroud forms a structural element of sufficient strength to support the vessel head, the control rod guide mechanism and the instrumentation tube structure, and includes radiation shielding material for limiting passage of radiation from retracted instrumentation tubes. The shroud is thicker at the bottom adjacent the vessel head, where the more irradiated lower ends of retracted sensors reside. The vessel head, shroud and contents thus can be removed from the reactor as a unit and rested safely and securely on a support.

  16. Performance Evaluation and Software Design for EVA Robotic Assistant Stereo Vision Heads

    NASA Technical Reports Server (NTRS)

    DiPaolo, Daniel

    2003-01-01

    The purpose of this project was to aid the EVA Robotic Assistant project by evaluating and designing the necessary interfaces for two stereo vision heads - the TracLabs Biclops pan-tilt-verge head, and the Helpmate Zebra pan-tilt-verge head. The first half of the project consisted of designing the necessary software interface so that the other modules of the EVA Robotic Assistant had proper access to all of the functionalities offered by each of the stereovision heads. This half took most of the project time, due to a lack of ready-made CORBA drivers for either of the heads. Once this was overcome, the evaluation stage of the project began. The second half of the project was to take these interfaces and to evaluate each of the stereo vision heads in terms of usefulness to the project. In the key project areas such as stability and reliability, the Zebra pan-tilt-verge head came out on top. However, the Biclops did have many more advantages over the Zebra, such as: lower power consumption, faster communications, and a simpler, cleaner API. Overall, the Biclops pan-tilt-verge head outperformed the Zebra pan-tilt-verge head.

  17. Analysis of a flare-director concept for an externally blown flap STOL aircraft

    NASA Technical Reports Server (NTRS)

    Middleton, D. B.

    1974-01-01

    A flare-director concept involving a thrust-required flare-guidance equation was developed and tested on a moving-base simulator. The equation gives a signal to command thrust as a linear function of the errors between the variables thrust, altitude, and altitude rate and corresponding values on a desired reference flare trajectory. During the simulator landing tests this signal drove either the horizontal command bar of the aircraft's flight director or a thrust-command dot on a head-up virtual-image display of a flare director. It was also used as the input to a simple autoflare system. An externally blown flap STOL (short take-off and landing) aircraft (with considerable stability and control augmentation) was modeled for the landing tests. The pilots considered the flare director a valuable guide for executing a proper flare-thrust program under instrument-landing conditions, but were reluctant to make any use of the head-up display when they were performing the landings visually.

  18. Omega-3 fatty acid-, micronutrient-, and probiotic-enriched nutrition helps body weight stabilization in head and neck cancer cachexia.

    PubMed

    Yeh, Kun-Yun; Wang, Hung-Ming; Chang, John W-C; Huang, Jen-Seng; Lai, Chien-Hong; Lan, Yii-Jenq; Wu, Tsung-Han; Chang, Pei-Hung; Wang, Hang; Wu, Chang-Jer; Hsia, Simon; Wang, Cheng-Hsu

    2013-07-01

    To evaluate whether an oral nutritional supplement enriched with omega-3 fatty acids, micronutrients, and probiotics affected body weight (BW) changes, serum albumin and prealbumin levels in patients with head and neck cancer (HNC) cachexia. Sixty-eight HNC patients were randomly assigned to receive either an Ethanwell/Ethanzyme (EE) regimen enriched with omega-3 fatty acids, micronutrients, and probiotics, or control (Isocal) for a 3-month period. Analysis of covariance was used to examine the association between BW change and variables. Patients with body mass index (BMI) <19 and those receiving the EE regimen consumed fewer daily calories but showed significantly increased BW and maintained higher serum albumin and prealbumin levels than other patients (P<.05). Their BW changes were significantly associated with changes in serum albumin and prealbumin levels. EE regimen improved BW as well as serum albumin and prealbumin levels in HNC patients with BMI <19. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Resonant tunneling across a ferroelectric domain wall

    NASA Astrophysics Data System (ADS)

    Li, M.; Tao, L. L.; Velev, J. P.; Tsymbal, E. Y.

    2018-04-01

    Motivated by recent experimental observations, we explore electron transport properties of a ferroelectric tunnel junction (FTJ) with an embedded head-to-head ferroelectric domain wall, using first-principles density-functional theory calculations. We consider a FTJ with L a0.5S r0.5Mn O3 electrodes separated by a BaTi O3 barrier layer and show that an in-plane charged domain wall in the ferroelectric BaTi O3 can be induced by polar interfaces. The resulting V -shaped electrostatic potential profile across the BaTi O3 layer creates a quantum well and leads to the formation of a two-dimensional electron gas, which stabilizes the domain wall. The confined electronic states in the barrier are responsible for resonant tunneling as is evident from our quantum-transport calculations. We find that the resonant tunneling is an orbital selective process, which leads to sharp spikes in the momentum- and energy-resolved transmission spectra. Our results indicate that domain walls embedded in FTJs can be used to control the electron transport.

  20. Head Lice: Prevention and Control

    MedlinePlus

    ... and General Public. Contact Us Parasites Home Prevention & Control Language: English (US) Español (Spanish) Recommend on Facebook ... that can be taken to help prevent and control the spread of head lice: Avoid head-to- ...

  1. Product development: using a 3D computer model to optimize the stability of the Rocket powered wheelchair.

    PubMed

    Pinkney, S; Fernie, G

    2001-01-01

    A three-dimensional (3D) lumped-parameter model of a powered wheelchair was created to aid the development of the Rocket prototype wheelchair and to help explore the effect of innovative design features on its stability. The model was developed using simulation software, specifically Working Model 3D. The accuracy of the model was determined by comparing both its static stability angles and dynamic behavior as it passed down a 4.8-cm (1.9") road curb at a heading of 45 degrees with the performance of the actual wheelchair. The model's predictions of the static stability angles in the forward, rearward, and lateral directions were within 9.3, 7.1, and 3.8% of the measured values, respectively. The average absolute error in the predicted position of the wheelchair as it moved down the curb was 2.2 cm/m (0.9" per 3'3") traveled. The accuracy was limited by the inability to model soft bodies, the inherent difficulties in modeling a statically indeterminate system, and the computing time. Nevertheless, it was found to be useful in investigating the effect of eight design alterations on the lateral stability of the wheelchair. Stability was quantified by determining the static lateral stability angles and the maximum height of a road curb over which the wheelchair could successfully drive on a diagonal heading. The model predicted that the stability was more dependent on the configuration of the suspension system than on the dimensions and weight distribution of the wheelchair. Furthermore, for the situations and design alterations studied, predicted improvements in static stability were not correlated with improvements in dynamic stability.

  2. A research on the postural stability of a person wearing the lower limb exoskeletal robot by the HAT model.

    PubMed

    Chang, Minsu; Kim, Yeongmin; Lee, Yoseph; Jeon, Doyoung

    2017-07-01

    This paper proposes a method of detecting the postural stability of a person wearing the lower limb exoskeletal robot with the HAT(Head-Arm-Trunk) model. Previous studies have shown that the human posture is stable when the CoM(Center of Mass) of the human body is placed on the BoS(Base of Support). In the case of the lower limb exoskeletal robot, the motion data, which are used for the CoM estimation, are acquired by sensors in the robot. The upper body, however, does not have sensors in each segment so that it may cause the error of the CoM estimation. In this paper, the HAT(Head-Arm-Trunk) model which combines head, arms, and torso into a single segment is considered because the motion of head and arms are unknown due to the lack of sensors. To verify the feasibility of HAT model, the reflecting markers are attached to each segment of the whole human body and the exact motion data are acquired by the VICON to compare the COM of the full body model and HAT model. The difference between the CoM with full body and that with HAT model is within 20mm for the various motions of head and arms. Based on the HAT model, the XCoM(Extrapolated Center of Mass) which includes the velocity of the CoM is used for prediction of the postural stability. The experiment of making unstable posture shows that the XCoM of the whole body based on the HAT model is feasible to detect the instance of postural instability earlier than the CoM by 20-250 msec. This result may be used for the lower limb exoskeletal robot to prepare for any action to prevent the falling down.

  3. Non-invasive primate head restraint using thermoplastic masks.

    PubMed

    Drucker, Caroline B; Carlson, Monica L; Toda, Koji; DeWind, Nicholas K; Platt, Michael L

    2015-09-30

    The success of many neuroscientific studies depends upon adequate head fixation of awake, behaving animals. Typically, this is achieved by surgically affixing a head-restraint prosthesis to the skull. Here we report the use of thermoplastic masks to non-invasively restrain monkeys' heads. Mesh thermoplastic sheets become pliable when heated and can then be molded to an individual monkey's head. After cooling, the custom mask retains this shape indefinitely for day-to-day use. We successfully trained rhesus macaques (Macaca mulatta) to perform cognitive tasks while wearing thermoplastic masks. Using these masks, we achieved a level of head stability sufficient for high-resolution eye-tracking and intracranial electrophysiology. Compared with traditional head-posts, we find that thermoplastic masks perform at least as well during infrared eye-tracking and single-neuron recordings, allow for clearer magnetic resonance image acquisition, enable freer placement of a transcranial magnetic stimulation coil, and impose lower financial and time costs on the lab. We conclude that thermoplastic masks are a viable non-invasive form of primate head restraint that enable a wide range of neuroscientific experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Pulse tube cryocooler for IR applications

    NASA Astrophysics Data System (ADS)

    Korf, H.; Ruhlich, I.; Mai, M.; Thummes, G.

    2005-05-01

    Pulse tube cryocoolers (PTC) can be regarded as the next step in the development of the Stirling cooler. The major advantage vs. the Stirling cooler is the omission of any moving part in the cold head, resulting in significantly increased MTTF. Further advantages are higher mechanical robustness and stability and the potential for cost reduction. AIM developed PTC's for several years in close cooperation with the University of Giessen. As a recent result at AIM, Coaxial PTC cold head are available within the outline dimension of typical IR Stirling cold head of 13mm diameter. The achieved performance data are comparable to the serial data of the Stirling cold head. This PTC cold head is designed to be operated in the orifice mode without a double inlet which is known to cause instabilities. Technical details and performance data represent the current technical status at AIM.

  5. Fluidized-Bed Drying and Storage Stability of Cryptococcus flavescens OH 182.9, a Biocontrol Agent of Fusarium Head Blight

    USDA-ARS?s Scientific Manuscript database

    A method to produce dried granules of Cryptococcus flavescens (formerly Cryptococcus nodaensis) OH 182.9 was developed and the granules evaluated for storage stability. Small spherical granules were produced and dried using a fluidized bed dryer. A drying and survival curve was produced for the pr...

  6. Biochemical and physical factors affecting discoloration characteristics of 19 bovine muscles.

    PubMed

    McKenna, D R; Mies, P D; Baird, B E; Pfeiffer, K D; Ellebracht, J W; Savell, J W

    2005-08-01

    Steaks from muscles (n=19 from nine beef carcasses) were evaluated over the course of retail display (0-, 1-, 2-, 3-, 4- or 5-d) for objective measures of discoloration (metmyoglobin, oxymyoglobin, L*-, a*-, and b*-values), reducing ability (metmyoglobin reductase activity (MRA), resistance to induced metmyoglobin formation (RIMF), and nitric oxide metmyoglobin reducing ability (NORA)), oxygen consumption rate (OCR), oxygen penetration depth, myoglobin content, oxidative rancidity, and pH. Muscles were grouped according to objective color measures of discoloration. M. longissimus lumborum, M. longissimus thoracis, M. semitendinosus, and M. tensor fasciae latae were grouped as "high" color stability muscles, M. semimembranosus, M. rectus femoris, and M. vastus lateralis were grouped as "moderate" color stability muscles, M. trapezius, M. gluteus medius, and M. latissimus dorsi were grouped as "intermediate" color stability muscles, M. triceps brachi - long head, M. biceps femoris, M. pectoralis profundus, M. adductor, M. triceps brachi - lateral head, and M. serratus ventralis were grouped as "low" color stability muscles, and M. supraspinatus, M. infraspinatus, and M. psoas major were grouped as "very low" color stability muscles. Generally, muscles of high color stability had high RIMF, nitric oxide reducing ability, and oxygen penetration depth and possessed low OCRs, myoglobin content, and oxidative rancidity. In contrast, muscles of low color stability had high MRA, OCRs, myoglobin content, and oxidative rancidity and low RIMF, NORA, and oxygen penetration depth. Data indicate that discoloration differences between muscles are related to the amount of reducing activity relative to the OCR.

  7. The problem of the driverless vehicle specified path stability control

    NASA Astrophysics Data System (ADS)

    Buznikov, S. E.; Endachev, D. V.; Elkin, D. S.; Strukov, V. O.

    2018-02-01

    Currently the effort of many leading foreign companies is focused on creation of driverless transport for transportation of cargo and passengers. Among many practical problems arising while creating driverless vehicles, the problem of the specified path stability control occupies a central place. The purpose of this paper is formalization of the problem in question in terms of the quadratic functional of the control quality, the comparative analysis of the possible solutions and justification of the choice of the optimum technical solution. As square value of the integral of the deviation from the specified path is proposed as the quadratic functional of the control quality. For generation of the set of software and hardware solution variants the Zwicky “morphological box” method is used within the hardware and software environments. The heading control algorithms use the wheel steering angle data and the deviation from the lane centerline (specified path) calculated based on the navigation data and the data from the video system. Where the video system does not detect the road marking, the control is carried out based on the wheel navigation system data and where recognizable road marking exits - based on to the video system data. The analysis of the test results allows making the conclusion that the application of the combined navigation system algorithms that provide quasi-optimum solution of the problem while meeting the strict functional limits for the technical and economic indicators of the driverless vehicle control system under development is effective.

  8. Brain stem omnipause neurons and the control of combined eye-head gaze saccades in the alert cat.

    PubMed

    Paré, M; Guitton, D

    1998-06-01

    When the head is unrestrained, rapid displacements of the visual axis-gaze shifts (eye-re-space)-are made by coordinated movements of the eyes (eye-re-head) and head (head-re-space). To address the problem of the neural control of gaze shifts, we studied and contrasted the discharges of omnipause neurons (OPNs) during a variety of combined eye-head gaze shifts and head-fixed eye saccades executed by alert cats. OPNs discharged tonically during intersaccadic intervals and at a reduced level during slow perisaccadic gaze movements sometimes accompanying saccades. Their activity ceased for the duration of the saccadic gaze shifts the animal executed, either by head-fixed eye saccades alone or by combined eye-head movements. This was true for all types of gaze shifts studied: active movements to visual targets; passive movements induced by whole-body rotation or by head rotation about stationary body; and electrically evoked movements by stimulation of the caudal part of the superior colliculus (SC), a central structure for gaze control. For combined eye-head gaze shifts, the OPN pause was therefore not correlated to the eye-in-head trajectory. For instance, in active gaze movements, the end of the pause was better correlated with the gaze end than with either the eye saccade end or the time of eye counterrotation. The hypothesis that cat OPNs participate in controlling gaze shifts is supported by these results, and also by the observation that the movements of both the eyes and the head were transiently interrupted by stimulation of OPNs during gaze shifts. However, we found that the OPN pause could be dissociated from the gaze-motor-error signal producing the gaze shift. First, OPNs resumed discharging when perturbation of head motion briefly interrupted a gaze shift before its intended amplitude was attained. Second, stimulation of caudal SC sites in head-free cat elicited large head-free gaze shifts consistent with the creation of a large gaze-motor-error signal. However, stimulation of the same sites in head-fixed cat produced small "goal-directed" eye saccades, and OPNs paused only for the duration of the latter; neither a pause nor an eye movement occurred when the same stimulation was applied with the eyes at the goal location. We conclude that OPNs can be controlled by neither a simple eye control system nor an absolute gaze control system. Our data cannot be accounted for by existing models describing the control of combined eye-head gaze shifts and therefore put new constraints on future models, which will have to incorporate all the various signals that act synergistically to control gaze shifts.

  9. A novel protocol for generating intact, whole-head spider cephalothorax tissue sections.

    PubMed

    Long, Skye M

    2018-04-01

    The diversity of spider behavior and sensory systems provides an excellent opportunity for comparative studies of the relationship between the brain and behavior. However, the morphology of spiders poses a challenge for histologists since the spider cephalothorax contains heterogeneous tissues and has both tough external and internal sclerotized regions. Unlike the heads of insects, the cephalothorax is highly pressurized, which can cause tissues to shift during processing and can reduce tissue cohesion in thick sections. This work describes a novel protocol for producing thick whole-head sections for morphological study by softening the exoskeleton and stabilizing friable tissue, without freezing or dehydration. It also presents an effective whole-head DiI staining method that uses minimal dehydration and highlights neural structures.

  10. Preferential recognition of undisruptable dimers of inducible nitric oxide synthase by a monoclonal antibody directed against an N-terminal epitope.

    PubMed

    Mazumdar, Tuhina; Eissa, N Tony

    2005-02-15

    Overproduction of NO by inducible NO synthase (iNOS) has been implicated in the pathogenesis of many diseases. iNOS is active only as a homodimer in which the subunits align in a head-to-head manner, with the N-terminal oxygenase domains forming the dimer interface and a zinc metal center stabilizing the dimer. Thus, dimerization represents a critical locus for therapeutic interventions for regulation of NO synthesis. We have recently shown that intracellular iNOS forms dimers that are "undisruptable (UD)" by heat, SDS, strong denaturants, and/or reducing agents. Our data further suggest that the zinc metal center plays a role in forming and/or stabilizing iNOS undisruptable dimers (UD-dimers). In this study, we show that a mAb directed against a unique epitope at the oxygenase domain of human iNOS preferentially recognizes UD-dimers. This observation has implications for the mechanism of formation and regulation of dimer formation of iNOS. Our data suggest that UD-dimers of iNOS, in spite of SDS-PAGE denaturation, still maintain features of the quaternary structure of iNOS particularly at its N-terminal end and including head-to-head contact of the oxygenase domains.

  11. Smooth-pursuit eye movements without head movement disrupt the static body balance.

    PubMed

    Kim, Sang-Yeob; Moon, Byeong-Yeon; Cho, Hyun Gug

    2016-04-01

    [Purpose] To investigate the changes of body balance in static posture in smooth-pursuit eye movements (SPEMs) without head movement. [Subjects and Methods] Forty subjects (24 males, 16 females) aged 23.24 ± 2.58 years participated. SPEMs were activated in three directions (horizontal, vertical, and diagonal movements); the target speed was set at three conditions (10°/s, 20°/s, and 30°/s); and the binocular visual field was limited to 50°. To compare the body balance changes, the general stability (ST) and the fall risk index (FI) were measured with TETRAX. The subjects wore a head-neck collar and stood on a balance plate for 32 s during each measurement in three directions. SPEMs were induced to each subject with nine target speeds and directions. All measured values were compared with those in stationary fixation. [Results] The ST and FI increased significantly in all SPEMs directions, with an increased target speed than that in stationary fixation. In the same condition of the target speed, the FI had the highest value relative to diagonal SPEMs. [Conclusion] SPEMs without head movement disrupt the stability of body balance in a static posture, and diagonal SPEMs may have a more negative effect in maintaining body balance than horizontal or vertical SPEMs.

  12. Are Covert Saccade Functionally Relevant in Vestibular Hypofunction?

    PubMed

    Hermann, R; Pelisson, D; Dumas, O; Urquizar, Ch; Truy, E; Tilikete, C

    2018-06-01

    The vestibulo-ocular reflex maintains gaze stabilization during angular or linear head accelerations, allowing adequate dynamic visual acuity. In case of bilateral vestibular hypofunction, patients use saccades to compensate for the reduced vestibulo-ocular reflex function, with covert saccades occurring even during the head displacement. In this study, we questioned whether covert saccades help maintain dynamic visual acuity, and evaluated which characteristic of these saccades are the most relevant to improve visual function. We prospectively included 18 patients with chronic bilateral vestibular hypofunction. Subjects underwent evaluation of dynamic visual acuity in the horizontal plane as well as video recording of their head and eye positions during horizontal head impulse tests in both directions (36 ears tested). Frequency, latency, consistency of covert saccade initiation, and gain of covert saccades as well as residual vestibulo-ocular reflex gain were calculated. We found no correlation between residual vestibulo-ocular reflex gain and dynamic visual acuity. Dynamic visual acuity performance was however positively correlated with the frequency and gain of covert saccades and negatively correlated with covert saccade latency. There was no correlation between consistency of covert saccade initiation and dynamic visual acuity. Even though gaze stabilization in space during covert saccades might be of very short duration, these refixation saccades seem to improve vision in patients with bilateral vestibular hypofunction during angular head impulses. These findings emphasize the need for specific rehabilitation technics that favor the triggering of covert saccades. The physiological origin of covert saccades is discussed.

  13. Resolution of sensory ambiguities for gaze stabilization requires a second neural integrator

    NASA Technical Reports Server (NTRS)

    Green, Andrea M.; Angelaki, Dora E.

    2003-01-01

    The ability to simultaneously move in the world and maintain stable visual perception depends critically on the contribution of vestibulo-ocular reflexes (VORs) to gaze stabilization. It is traditionally believed that semicircular canal signals drive compensatory responses to rotational head disturbances (rotational VOR), whereas otolith signals compensate for translational movements [translational VOR (TVOR)]. However, a sensory ambiguity exists because otolith afferents are activated similarly during head translations and reorientations relative to gravity (i.e., tilts). Extra-otolith cues are, therefore, necessary to ensure that dynamic head tilts do not elicit a TVOR. To investigate how extra-otolith signals contribute, we characterized the temporal and viewing distance-dependent properties of a TVOR elicited in the absence of a lateral acceleration stimulus to the otoliths during combined translational/rotational motion. We show that, in addition to otolith signals, angular head position signals derived by integrating sensory canal information drive the TVOR. A physiological basis for these results is proposed in a model with two distinct integration steps. Upstream of the well known oculomotor velocity-to-position neural integrator, the model incorporates a separate integration element that could represent the "velocity storage integrator," whose functional role in the oculomotor system has so far remained controversial. We propose that a key functional purpose of the velocity storage network is to temporally integrate semicircular canal signals, so that they may be used to extract translation information from ambiguous otolith afferent signals in the natural and functionally relevant bandwidth of head movements.

  14. Early intensive postural and movement training advances head control in very young infants.

    PubMed

    Lee, Hui-Min; Galloway, James Cole

    2012-07-01

    Daily experiences are thought to play an important role in motor development during infancy. There are limited studies on the effect of postural and movement experiences on head control. The purpose of this study was to quantify the effects of postural and movement experiences on head control through a comprehensive set of measurements beginning when infants were 1 month old. This was a prospective, longitudinal, 2-cohort study. Twenty-two full-term infants who were healthy were randomly assigned to either a training group or a control group. Infants were observed every other week from 1 to 4 months of age. Head control was assessed using a standardized developmental assessment tool, the Test of Infant Motor Performance (TIMP), as well as behavioral coding and kinematics of infants' head postures and movements in a supported sitting position. Caregivers performed at least 20 minutes of daily postural and movement activities (training group), or social interaction (control group) for 4 weeks. The training group had higher TIMP scores on head control-related items during the training period and after training stopped compared with the control group. Starting from the during training phase, the training group infants had their heads in a vertical and midline position longer compared with the control group infants. After training stopped, the training group infants actively moved their heads forward more often and for larger distances. The experiences outside daily training were not monitored, and the results may be specific to the experimental setup for infants with typical development. Young infants are able to take advantage of postural and movement experiences to rapidly advance their head control as early as 4 to 6 weeks of postnatal life. Infant positioning, caregiver handling, and caregiver-infant interactions were likely contributing factors. This database of comprehensive measures may be useful in future trials focused on head control in infants with special needs.

  15. Effects of trunk-to-head rotation on the labyrinthine responses of rat reticular neurons.

    PubMed

    Barresi, M; Grasso, C; Bruschini, L; Berrettini, S; Manzoni, D

    2012-11-08

    Vestibulospinal reflexes elicited by head displacement become appropriate for body stabilization owing to the integration of neck input by the cerebellar anterior vermis. Due to this integration, the preferred direction of spinal motoneurons' responses to animal tilt rotates by the same angle and by the same direction as the head over the body, which makes it dependent on the direction of body displacement rather than on head displacement. It is known that the cerebellar control of spinal motoneurons involves the reticular formation. Since the preferred directions of corticocerebellar units' responses to animal tilt are tuned by neck rotation, as occuring in spinal motoneurons, we investigated whether a similar tuning can be observed also in the intermediate station of reticular formation. In anaesthetized rats, the activity of neurons in the medullary reticular formation was recorded during wobble of the whole animal at 0.156 Hz, a stimulus that tilted the animal's head by a constant amplitude (5°), in a direction rotating clockwise or counter clockwise over the horizontal plane. The response gain and the direction of tilt eliciting the maximal activity were evaluated with the head and body axes aligned and during a maintained body-to-head displacement of 5-20° over the horizontal plane, in either direction. We found that the neck displacement modified the response gain and/or the average activity of most of the responsive neurons. Rotation of the response direction was observed only in a minor percentage of the recorded neurons. The modifications of reticular neurons' responses were different from those observed in the P-cells of the cerebellar anterior vermis, which rarely showed gain and activity changes and often exhibited a rotation of their response directions. In conclusion, reticular neurons take part in the neck tuning of vestibulospinal reflexes by transforming a head-driven sensory input into a body-centred postural response. The present findings prompt re-evaluation of the role played by the reticular neurons and the cerebellum in vestibulospinal reflexes. Copyright © 2012 IBRO. Published by Elsevier Ltd. All rights reserved.

  16. Upper body kinematics in patients with cerebellar ataxia.

    PubMed

    Conte, Carmela; Pierelli, Francesco; Casali, Carlo; Ranavolo, Alberto; Draicchio, Francesco; Martino, Giovanni; Harfoush, Mahmoud; Padua, Luca; Coppola, Gianluca; Sandrini, Giorgio; Serrao, Mariano

    2014-12-01

    Although abnormal oscillations of the trunk are a common clinical feature in patients with cerebellar ataxia, the kinematic behaviour of the upper body in ataxic patients has yet to be investigated in quantitative studies. In this study, an optoelectronic motion analysis system was used to measure the ranges of motion (ROMs) of the head and trunk segments in the sagittal, frontal and yaw planes in 16 patients with degenerative cerebellar ataxia during gait at self-selected speed. The data obtained were compared with those collected in a gender-, age- and gait speed-matched sample of healthy subjects and correlated with gait variables (time-distance means and coefficients of variation) and clinical variables (disease onset, duration and severity). The results showed significantly larger head and/or trunk ROMs in ataxic patients compared with controls in all three spatial planes, and significant correlations between trunk ROMs and disease duration and severity (in sagittal and frontal planes) and time-distance parameters (in the yaw plane), and between both head and trunk ROMs and swing phase duration variability (in the sagittal plane). Furthermore, the ataxic patients showed a flexed posture of both the head and the trunk during walking. In conclusion, our study revealed abnormal motor behaviour of the upper body in ataxic patients, mainly resulting in a flexed posture and larger oscillations of the head and trunk. The results of the correlation analyses suggest that the longer and more severe the disease, the larger the upper body oscillations and that large trunk oscillations may explain some aspects of gait variability. These results suggest the need of specific rehabilitation treatments or the use of elastic orthoses that may be particularly useful to reduce trunk oscillations and improve dynamic stability.

  17. Investigation of the Differential Contributions of Superficial and Deep Muscles on Cervical Spinal Loads with Changing Head Postures

    PubMed Central

    Cheng, Chih-Hsiu; Chien, Andy; Hsu, Wei-Li; Chen, Carl Pai-Chu; Cheng, Hsin-Yi Kathy

    2016-01-01

    Cervical spinal loads are predominately influenced by activities of cervical muscles. However, the coordination between deep and superficial muscles and their influence on the spinal loads is not well understood. This study aims to document the changes of cervical spinal loads and the differential contributions of superficial and deep muscles with varying head postures. Electromyography (EMG) of cervical muscles from seventeen healthy adults were measured during maximal isometric exertions for lateral flexion (at 10°, 20° and terminal position) as well as flexion/extension (at 10°, 20°, 30°, and terminal position) neck postures. An EMG-assisted optimization approach was used to estimate the muscle forces and subsequent spinal loads. The results showed that compressive and anterior-posterior shear loads increased significantly with neck flexion. In particular, deep muscle forces increased significantly with increasing flexion. It was also determined that in all different static head postures, the deep muscle forces were greater than those of the superficial muscle forces, however, such pattern was reversed during peak efforts where greater superficial muscle forces were identified with increasing angle of inclination. In summary, the identification of significantly increased spinal loads associated with increased deep muscle activation during flexion postures, implies higher risks in predisposing the neck to occupationally related disorders. The results also explicitly supported that deep muscles play a greater role in maintaining stable head postures where superficial muscles are responsible for peak exertions and reinforcing the spinal stability at terminal head postures. This study provided quantitative data of normal cervical spinal loads and revealed motor control strategies in coordinating the superficial and deep muscles during physical tasks. PMID:26938773

  18. Investigation of the Differential Contributions of Superficial and Deep Muscles on Cervical Spinal Loads with Changing Head Postures.

    PubMed

    Cheng, Chih-Hsiu; Chien, Andy; Hsu, Wei-Li; Chen, Carl Pai-Chu; Cheng, Hsin-Yi Kathy

    2016-01-01

    Cervical spinal loads are predominately influenced by activities of cervical muscles. However, the coordination between deep and superficial muscles and their influence on the spinal loads is not well understood. This study aims to document the changes of cervical spinal loads and the differential contributions of superficial and deep muscles with varying head postures. Electromyography (EMG) of cervical muscles from seventeen healthy adults were measured during maximal isometric exertions for lateral flexion (at 10°, 20° and terminal position) as well as flexion/extension (at 10°, 20°, 30°, and terminal position) neck postures. An EMG-assisted optimization approach was used to estimate the muscle forces and subsequent spinal loads. The results showed that compressive and anterior-posterior shear loads increased significantly with neck flexion. In particular, deep muscle forces increased significantly with increasing flexion. It was also determined that in all different static head postures, the deep muscle forces were greater than those of the superficial muscle forces, however, such pattern was reversed during peak efforts where greater superficial muscle forces were identified with increasing angle of inclination. In summary, the identification of significantly increased spinal loads associated with increased deep muscle activation during flexion postures, implies higher risks in predisposing the neck to occupationally related disorders. The results also explicitly supported that deep muscles play a greater role in maintaining stable head postures where superficial muscles are responsible for peak exertions and reinforcing the spinal stability at terminal head postures. This study provided quantitative data of normal cervical spinal loads and revealed motor control strategies in coordinating the superficial and deep muscles during physical tasks.

  19. Community rating and sustainable individual health insurance markets in New Jersey.

    PubMed

    Monheit, Alan C; Cantor, Joel C; Koller, Margaret; Fox, Kimberley S

    2004-01-01

    The New Jersey Individual Health Coverage Program (IHCP) was implemented in 1993; key provisions included pure community rating and guaranteed issue/renewal of coverage. Despite positive early evaluations, the IHCP appears to be heading for collapse. Using unique administrative and survey data, we examined trends in IHCP enrollment and premiums. We found the stability of the IHCP to be fragile in light of improving opportunities for job-related health insurance. We also found that it is retaining high-risk enrollees. Institutional realities and the difficulty of identifying a control group preclude attributing causality to the plan's pure community rating and open enrollment provisions.

  20. STOLAND

    NASA Technical Reports Server (NTRS)

    Grgurich, J.; Bradbury, P.

    1976-01-01

    The STOLAND system includes air data, navigation, guidance, flight director (including a throttle flight director on the Augmentor Wing), 3-axis autopilot and autothrottle functions. The 3-axis autopilot and autothrottle control through parallel electric servos on both aircraft and on the augmentor wing, the system also interfaces with three electrohydraulic series actuators which drive the roll control surfaces, elevator and rudder. The system incorporates automatic configuration control of the flaps and nozzles on the augmentor wing and of the flaps on the Twin Otter. Interfaces are also provided to control the wing flap chokes on the Augmentor Wing and the spoilers on the Twin Otter. The STOLAND system has all the capabilities of a conventional integrated avionics system. Aircraft stabilization is provided in pitch, roll and yaw including control wheel steering in pitch and roll. The basic modes include altitude hold and select, indicated airspeed hold and select, flight path angle hold and select, and heading hold and select. The system can couple to TACAN and VOR/DME navaids for conventional radial flying.

  1. Bounded extremum seeking for angular velocity actuated control of nonholonomic unicycle

    DOE PAGES

    Scheinker, Alexander

    2016-08-17

    Here, we study control of the angular-velocity actuated nonholonomic unicycle, via a simple, bounded extremum seeking controller which is robust to external disturbances and measurement noise. The vehicle performs source seeking despite not having any position information about itself or the source, able only to sense a noise corrupted scalar value whose extremum coincides with the unknown source location. In order to control the angular velocity, rather than the angular heading directly, a controller is developed such that the closed loop system exhibits multiple time scales and requires an analysis approach expanding the previous work of Kurzweil, Jarnik, Sussmann, andmore » Liu, utilizing weak limits. We provide analytic proof of stability and demonstrate how this simple scheme can be extended to include position-independent source seeking, tracking, and collision avoidance of groups on autonomous vehicles in GPS-denied environments, based only on a measure of distance to an obstacle, which is an especially important feature for an autonomous agent.« less

  2. Dose calculation accuracy of different image value to density tables for cone-beam CT planning in head & neck and pelvic localizations.

    PubMed

    Barateau, Anaïs; Garlopeau, Christopher; Cugny, Audrey; De Figueiredo, Bénédicte Henriques; Dupin, Charles; Caron, Jérôme; Antoine, Mikaël

    2015-03-01

    We aimed to identify the most accurate combination of phantom and protocol for image value to density table (IVDT) on volume-modulated arc therapy (VMAT) dose calculation based on kV-Cone-beam CT imaging, for head and neck (H&N) and pelvic localizations. Three phantoms (Catphan(®)600, CIRS(®)062M (inner phantom for head and outer phantom for body), and TomoTherapy(®) "Cheese" phantom) were used to create IVDT curves of CBCT systems with two different CBCT protocols (Standard-dose Head and Standard Pelvis). Hounsfield Unit (HU) time stability and repeatability for a single On-Board-Imager (OBI) and compatibility of two distinct devices were assessed with Catphan(®)600. Images from the anthropomorphic phantom CIRS ATOM(®) for both CT and CBCT modalities were used for VMAT dose calculation from different IVDT curves. Dosimetric indices from CT and CBCT imaging were compared. IVDT curves from CBCT images were highly different depending on phantom used (up to 1000 HU for high densities) and protocol applied (up to 200 HU for high densities). HU time stability was verified over seven weeks. A maximum difference of 3% on the dose calculation indices studied was found between CT and CBCT VMAT dose calculation across the two localizations using appropriate IVDT curves. One IVDT curve per localization can be established with a bi-monthly verification of IVDT-CBCT. The IVDT-CBCTCIRS-Head phantom with the Standard-dose Head protocol was the most accurate combination for dose calculation on H&N CBCT images. For pelvic localizations, the IVDT-CBCTCheese established with the Standard Pelvis protocol provided the best accuracy. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Effects of space flight on locomotor control

    NASA Technical Reports Server (NTRS)

    Bloomberg, Jacob J.; Layne, Charles S.; McDonald, P. Vernon; Peters, Brian T.; Huebner, William P.; Reschke, Millard F.; Berthoz, Alain; Glasauer, Stefan; Newman, Dava; Jackson, D. Keoki

    1999-01-01

    In the microgravity environment of spaceflight, the relationship between sensory input and motor output is altered. During prolonged missions, neural adaptive processes come into play to recalibrate central nervous system function, thereby permitting new motor control strategies to emerge in the novel sensory environment of microgravity. However, the adaptive state achieved during spaceflight is inappropriate for a unit gravity environment and leads to motor control alterations upon return to Earth that include disturbances in locomotion. Indeed, gait and postural instabilities following the return to Earth have been reported in both U.S. astronauts and Russian cosmonauts even after short duration (5- to 10-day) flights. After spaceflight, astronauts may: (1) experience the sensation of turning while attempting to walk a straight path, (2) encounter sudden loss of postural stability, especially when rounding corners, (3) perceive exaggerated pitch and rolling head movements during walking, (4) experience sudden loss of orientation in unstructured visual environments, or (5) experience significant oscillopsia during locomotion.

  4. Multimodal Integration of Self-Motion Cues in the Vestibular System: Active versus Passive Translations

    PubMed Central

    Carriot, Jerome; Brooks, Jessica X.

    2013-01-01

    The ability to keep track of where we are going as we navigate through our environment requires knowledge of our ongoing location and orientation. In response to passively applied motion, the otolith organs of the vestibular system encode changes in the velocity and direction of linear self-motion (i.e., heading). When self-motion is voluntarily generated, proprioceptive and motor efference copy information is also available to contribute to the brain's internal representation of current heading direction and speed. However to date, how the brain integrates these extra-vestibular cues with otolith signals during active linear self-motion remains unknown. Here, to address this question, we compared the responses of macaque vestibular neurons during active and passive translations. Single-unit recordings were made from a subgroup of neurons at the first central stage of sensory processing in the vestibular pathways involved in postural control and the computation of self-motion perception. Neurons responded far less robustly to otolith stimulation during self-generated than passive head translations. Yet, the mechanism underlying the marked cancellation of otolith signals did not affect other characteristics of neuronal responses (i.e., baseline firing rate, tuning ratio, orientation of maximal sensitivity vector). Transiently applied perturbations during active motion further established that an otolith cancellation signal was only gated in conditions where proprioceptive sensory feedback matched the motor-based expectation. Together our results have important implications for understanding the brain's ability to ensure accurate postural and motor control, as well as perceptual stability, during active self-motion. PMID:24336720

  5. Gravity and perceptual stability during translational head movement on earth and in microgravity.

    PubMed

    Jaekl, P; Zikovitz, D C; Jenkin, M R; Jenkin, H L; Zacher, J E; Harris, L R

    2005-01-01

    We measured the amount of visual movement judged consistent with translational head movement under normal and microgravity conditions. Subjects wore a virtual reality helmet in which the ratio of the movement of the world to the movement of the head (visual gain) was variable. Using the method of adjustment under normal gravity 10 subjects adjusted the visual gain until the visual world appeared stable during head movements that were either parallel or orthogonal to gravity. Using the method of constant stimuli under normal gravity, seven subjects moved their heads and judged whether the virtual world appeared to move "with" or "against" their movement for several visual gains. One subject repeated the constant stimuli judgements in microgravity during parabolic flight. The accuracy of judgements appeared unaffected by the direction or absence of gravity. Only the variability appeared affected by the absence of gravity. These results are discussed in relation to discomfort during head movements in microgravity. c2005 Elsevier Ltd. All rights reserved.

  6. Turning semicircular canal function on its head: dinosaurs and a novel vestibular analysis.

    PubMed

    Georgi, Justin A; Sipla, Justin S; Forster, Catherine A

    2013-01-01

    Previous investigations have correlated vestibular function to locomotion in vertebrates by scaling semicircular duct radius of curvature to body mass. However, this method fails to discriminate bipedal from quadrupedal non-avian dinosaurs. Because they exhibit a broad range of relative head sizes, we use dinosaurs to test the hypothesis that semicircular ducts scale more closely with head size. Comparing the area enclosed by each semicircular canal to estimated body mass and to two different measures of head size, skull length and estimated head mass, reveals significant patterns that corroborate a connection between physical parameters of the head and semicircular canal morphology. Head mass more strongly correlates with anterior semicircular canal size than does body mass and statistically separates bipedal from quadrupedal taxa, with bipeds exhibiting relatively larger canals. This morphologic dichotomy likely reflects adaptations of the vestibular system to stability demands associated with terrestrial locomotion on two, versus four, feet. This new method has implications for reinterpreting previous studies and informing future studies on the connection between locomotion type and vestibular function.

  7. Turning Semicircular Canal Function on Its Head: Dinosaurs and a Novel Vestibular Analysis

    PubMed Central

    Georgi, Justin A.; Sipla, Justin S.; Forster, Catherine A.

    2013-01-01

    Previous investigations have correlated vestibular function to locomotion in vertebrates by scaling semicircular duct radius of curvature to body mass. However, this method fails to discriminate bipedal from quadrupedal non-avian dinosaurs. Because they exhibit a broad range of relative head sizes, we use dinosaurs to test the hypothesis that semicircular ducts scale more closely with head size. Comparing the area enclosed by each semicircular canal to estimated body mass and to two different measures of head size, skull length and estimated head mass, reveals significant patterns that corroborate a connection between physical parameters of the head and semicircular canal morphology. Head mass more strongly correlates with anterior semicircular canal size than does body mass and statistically separates bipedal from quadrupedal taxa, with bipeds exhibiting relatively larger canals. This morphologic dichotomy likely reflects adaptations of the vestibular system to stability demands associated with terrestrial locomotion on two, versus four, feet. This new method has implications for reinterpreting previous studies and informing future studies on the connection between locomotion type and vestibular function. PMID:23516495

  8. Extra-domain B in oncofetal fibronectin structurally promotes fibrillar head-to-tail dimerization of extracellular matrix protein.

    PubMed

    Schiefner, André; Gebauer, Michaela; Skerra, Arne

    2012-05-18

    The type III extra-domain B (ED-B) is specifically spliced into fibronectin (Fn) during embryogenesis and neoangiogenesis, including many cancers. The x-ray structure of the recombinant four-domain fragment Fn(III)7B89 reveals a tightly associated, extended head-to-tail dimer, which is stabilized via pair-wise shape and charge complementarity. A tendency toward ED-B-dependent dimer formation in solution was supported by size exclusion chromatography and analytical ultracentrifugation. When amending the model with the known three-dimensional structure of the Fn(III)10 domain, its RGD loop as well as the adhesion synergy region in Fn(III)9-10 become displayed on the same face of the dimer; this should allow simultaneous binding of at least two integrins and, thus, receptor clustering on the cell surface and intracellular signaling. Insertion of ED-B appears to stabilize overall head-to-tail dimerization of two separate Fn chains, which, together with alternating homodimer formation via disulfide bridges at the C-terminal Fn tail, should lead to the known macromolecular fibril formation.

  9. Trunk muscle exercises as a means of improving postural stability in people with Parkinson's disease: a protocol for a randomised controlled trial.

    PubMed

    Hubble, Ryan P; Naughton, Geraldine A; Silburn, Peter A; Cole, Michael H

    2014-12-31

    Exercise has been shown to improve clinical measures of strength, balance and mobility, and in some cases, has improved symptoms of tremor and rigidity in people with Parkinson's disease (PD). However, to date, no research has examined whether improvements in trunk control can remedy deficits in dynamic postural stability in this population. The proposed randomised controlled trial aims to establish whether a 12-week exercise programme aimed at improving dynamic postural stability in people with PD; (1) is more effective than education; (2) is more effective when training frequency is increased; and (3) provides greater long-term benefits than education. Forty-five community-dwelling individuals diagnosed with idiopathic PD with a falls history will be recruited. Participants will complete baseline assessments including tests of cognition, vision, disease severity, fear of falling, mobility and quality of life. Additionally, participants will complete a series of standing balance tasks to evaluate static postural stability, while dynamic postural control will be measured during walking using head and trunk-mounted three-dimensional accelerometers. Following baseline testing, participants will be randomly-assigned to one of three intervention groups, who will receive either exercise once per week, exercise 3 days/week, or education. Participants will repeat the same battery of tests conducted at baseline after the 12-week intervention and again following a further 12-week sustainability period. This study has the potential to show that low-intensity and progressive trunk exercises can provide a non-invasive and effective means for maintaining or improving postural stability for people with PD. Importantly, if the programme is noted to be effective, it could be easily performed by patients within their home environment or under the guidance of available allied health professionals. The protocol for this study is registered with the Australian New Zealand Clinical Trials Registry (ACTRN12613001175763). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Context-dependent olfactory enhancement of optomotor flight control in Drosophila.

    PubMed

    Chow, Dawnis M; Frye, Mark A

    2008-08-01

    Sensing and following the chemical plume of food odors is a fundamental challenge faced by many organisms. For flying insects, the task is complicated by wind that distorts the plume and buffets the fly. To maintain an upwind heading, and thus stabilize their orientation in a plume, insects such as flies and moths make use of strong context-specific visual equilibrium reflexes. For example, flying straight requires the regulation of image rotation across the eye, whereas minimizing side-slip and avoiding a collision require regulation of image expansion. In flies, visual rotation stabilizes plume tracking, but rotation and expansion optomotor responses are controlled by separate visual pathways. Are olfactory signals integrated with optomotor responses in a manner dependent upon visual context? We addressed this question by investigating the effect of an attractive food odor on active optomotor flight control. Odorant caused flies both to increase aerodynamic power output and to steer straighter. However, when challenged with wide-field optic flow, odor resulted in enhanced amplitude rotation responses but reduced amplitude expansion responses. For both visual conditions, flies tracked motion signals more closely in odor, an indication of increased saliency. These results suggest a simple search algorithm by which olfactory signals improve the salience of visual stimuli and modify optomotor control in a context-dependent manner, thereby enabling an animal to fly straight up a plume and approach odiferous objects.

  11. Relationships between Head Circumference, Brain Volume and Cognition in Children with Prenatal Alcohol Exposure

    PubMed Central

    Treit, Sarah; Zhou, Dongming; Chudley, Albert E.; Andrew, Gail; Rasmussen, Carmen; Nikkel, Sarah M.; Samdup, Dawa; Hanlon-Dearman, Ana; Loock, Christine; Beaulieu, Christian

    2016-01-01

    Head circumference is used together with other measures as a proxy for central nervous system damage in the diagnosis of fetal alcohol spectrum disorders, yet the relationship between head circumference and brain volume has not been investigated in this population. The objective of this study is to characterize the relationship between head circumference, brain volume and cognitive performance in a large sample of children with prenatal alcohol exposure (n = 144) and healthy controls (n = 145), aged 5–19 years. All participants underwent magnetic resonance imaging to yield brain volumes and head circumference, normalized to control for age and sex. Mean head circumference, brain volume, and cognitive scores were significantly reduced in the prenatal alcohol exposure group relative to controls, albeit with considerable overlap between groups. Males with prenatal alcohol exposure had reductions in all three measures, whereas females with prenatal alcohol exposure had reduced brain volumes and cognitive scores, but no difference in head circumference relative to controls. Microcephaly (defined here as head circumference ≤ 3rd percentile) occurred more often in prenatal alcohol exposed participants than controls, but 90% of the exposed sample had head circumferences above this clinical cutoff indicating that head circumference is not a sensitive marker of prenatal alcohol exposure. Normalized head circumference and brain volume were positively correlated in both groups, and subjects with very low head circumference typically had below-average brain volumes. Conversely, over half of the subjects with very low brain volumes had normal head circumferences, which may stem from differential effects of alcohol on the skeletal and nervous systems. There were no significant correlations between head circumference and any cognitive score. These findings confirm group-level reductions in head circumference and increased rates of microcephaly in children with prenatal alcohol exposure, but raise concerns about the predictive value of this metric at an individual-subject level. PMID:26928125

  12. Relationships between Head Circumference, Brain Volume and Cognition in Children with Prenatal Alcohol Exposure.

    PubMed

    Treit, Sarah; Zhou, Dongming; Chudley, Albert E; Andrew, Gail; Rasmussen, Carmen; Nikkel, Sarah M; Samdup, Dawa; Hanlon-Dearman, Ana; Loock, Christine; Beaulieu, Christian

    2016-01-01

    Head circumference is used together with other measures as a proxy for central nervous system damage in the diagnosis of fetal alcohol spectrum disorders, yet the relationship between head circumference and brain volume has not been investigated in this population. The objective of this study is to characterize the relationship between head circumference, brain volume and cognitive performance in a large sample of children with prenatal alcohol exposure (n = 144) and healthy controls (n = 145), aged 5-19 years. All participants underwent magnetic resonance imaging to yield brain volumes and head circumference, normalized to control for age and sex. Mean head circumference, brain volume, and cognitive scores were significantly reduced in the prenatal alcohol exposure group relative to controls, albeit with considerable overlap between groups. Males with prenatal alcohol exposure had reductions in all three measures, whereas females with prenatal alcohol exposure had reduced brain volumes and cognitive scores, but no difference in head circumference relative to controls. Microcephaly (defined here as head circumference ≤ 3rd percentile) occurred more often in prenatal alcohol exposed participants than controls, but 90% of the exposed sample had head circumferences above this clinical cutoff indicating that head circumference is not a sensitive marker of prenatal alcohol exposure. Normalized head circumference and brain volume were positively correlated in both groups, and subjects with very low head circumference typically had below-average brain volumes. Conversely, over half of the subjects with very low brain volumes had normal head circumferences, which may stem from differential effects of alcohol on the skeletal and nervous systems. There were no significant correlations between head circumference and any cognitive score. These findings confirm group-level reductions in head circumference and increased rates of microcephaly in children with prenatal alcohol exposure, but raise concerns about the predictive value of this metric at an individual-subject level.

  13. An Ex Vivo Model in Human Femoral Heads for Histopathological Study and Resonance Frequency Analysis of Dental Implant Primary Stability

    PubMed Central

    Hernández-Cortés, Pedro; Galindo-Moreno, Pablo; Catena, Andrés; Ortega-Oller, Inmaculada; Salas-Pérez, José; Gómez-Sánchez, Rafael; Aguilar, Mariano; Aguilar, David

    2014-01-01

    Objective. This study was designed to explore relationships of resonance frequency analysis (RFA)—assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. Material and Methods. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) (n = 7) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) (n = 10). Sixty 4.5 × 13 mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. Results. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) (P < 0.001), but not of the implants (P = 0.455) or of the interaction of the two factors (P = 0.848). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified (50.33 ± 2.92) heads than in fresh (66.93 ± 1.10) or fixated (70.77 ± 1.32) heads (both P < 0.001). The ISQ score (fresh) was significantly higher for those in OA (73.52 ± 1.92) versus OP (67.13 ± 1.09) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results (P > 0.5 in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both P > 0.08). Conclusion. Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies. PMID:24995307

  14. Role of Fungicides, Application of Nozzle Types, and the Resistance Level of Wheat Varieties in the Control of Fusarium Head Blight and Deoxynivalenol

    PubMed Central

    Mesterházy, Ákos; Tóth, Beáta; Varga, Monika; Bartók, Tibor; Szabó-Hevér, Ágnes; Farády, László; Lehoczki-Krsjak, Szabolcs

    2011-01-01

    Fungicide application is a key factor in the control of mycotoxin contamination in the harvested wheat grain. However, the practical results are often disappointing. In 2000-2004, 2006-2008 and 2007 and 2008, three experiments were made to test the efficacy of fungicide control on Fusarium Head Blight (FHB) in wheat and to find ways to improve control of the disease and toxin contamination. In a testing system we have used for 20 years, tebuconazole and tebuconazole + prothioconazole fungicides regularly reduced symptoms by about 80% with a correlating reduction in toxin contamination. Averages across the years normally show a correlation of r = 0.90 or higher. The stability differences (measured by the stability index) between the poorest and the best fungicides are about 10 or more times, differing slightly in mycotoxin accumulation, FHB index (severity) and Fusarium damaged kernels (FDK). The weak fungicides, like carbendazim, were effective only when no epidemic occurred or epidemic severity was at a very low level. Similar fungicide effects were seen on wheat cultivars which varied in FHB resistance. In this study, we found three fold differences in susceptibility to FHB between highly susceptible and moderately resistant cultivars when treated with fungicides. In the moderately resistant cultivars, about 50% of the fungicide treatments lowered the DON level below the regulatory limit. In the most susceptible cultivars, all fungicides failed to reduce mycotoxin levels low enough for grain acceptance, in spite of the fact that disease was significantly reduced. The results correlated well with the results of the large-scale field tests of fungicide application at the time of natural infection. The Turbo FloodJet nozzle reduced FHB incidence and DON contamination when compared to the TeeJet XR nozzle. Overall, the data suggest that significant decreases in FHB incidence and deoxynivalenol contamination in field situations are possible with proper fungicide applications. Additionally, small plot tests can be used to evaluate the quality of the field disease and toxin production. PMID:22174980

  15. Stabilization of gaze during circular locomotion in light. I. Compensatory head and eye nystagmus in the running monkey

    NASA Technical Reports Server (NTRS)

    Solomon, D.; Cohen, B.

    1992-01-01

    1. A rhesus and cynomolgus monkey were trained to run around the perimeter of a circular platform in light. We call this "circular locomotion" because forward motion had an angular component. Head and body velocity in space were recorded with angular rate sensors and eye movements with electrooculography (EOG). From these measurements we derived signals related to the angular velocity of the eyes in the head (Eh), of the head on the body (Hb), of gaze on the body (Gb), of the body in space (Bs), of gaze in space (Gs), and of the gain of gaze (Gb/Bs). 2. The monkeys had continuous compensatory nystagmus of the head and eyes while running, which stabilized Gs during the slow phases. The eyes established and maintained compensatory gaze velocities at the beginning and end of the slow phases. The head contributed to gaze velocity during the middle of the slow phases. Slow phase Gb was as high as 250 degrees/s, and targets were fixed for gaze angles as large as 90-140 degrees. 3. Properties of the visual surround affected both the gain and strategy of gaze compensation in the one monkey tested. Gains of Eh ranged from 0.3 to 1.1 during compensatory gaze nystagmus. Gains of Hb varied around 0.3 (0.2-0.7), building to a maximum as Eh dropped while running past sectors of interest. Consistent with predictions, gaze gains varied from below to above unity, when translational and angular body movements with regard to the target were in opposite or the same directions, respectively. 4. Gaze moved in saccadic shifts in the direction of running during quick phases. Most head quick phases were small, and at times the head only paused during an eye quick phase. Eye quick phases were larger, ranging up to 60 degrees. This is larger than quick phases during passive rotation or saccades made with the head fixed. 5. These data indicate that head and eye nystagmus are natural phenomena that support gaze compensation during locomotion. Despite differential utilization of the head and eyes in various conditions, Gb compensated for Bs. There are various frames of reference in which an estimate of angular velocity that drives the head and eyes could be based. We infer that body in space velocity (Bs) is likely to be represented centrally to provide this signal.

  16. Non-invasive primate head restraint using thermoplastic masks

    PubMed Central

    Drucker, Caroline B.; Carlson, Monica L.; Toda, Koji; DeWind, Nicholas K.; Platt, Michael L.

    2015-01-01

    Background The success of many neuroscientific studies depends upon adequate head fixation of awake, behaving animals. Typically, this is achieved by surgically affixing a head-restraint prosthesis to the skull. New Method Here we report the use of thermoplastic masks to non-invasively restrain monkeys’ heads. Mesh thermoplastic sheets become pliable when heated and can then be molded to an individual monkey’s head. After cooling, the custom mask retains this shape indefinitely for day-to-day use. Results We successfully trained rhesus macaques (Macaca mulatta) to perform cognitive tasks while wearing thermoplastic masks. Using these masks, we achieved a level of head stability sufficient for high-resolution eye-tracking and intracranial electrophysiology. Comparison with Existing Method Compared with traditional head-posts, we find that thermoplastic masks perform at least as well during infrared eye-tracking and single-neuron recordings, allow for clearer magnetic resonance image acquisition, enable freer placement of a transcranial magnetic stimulation coil, and impose lower financial and time costs on the lab. Conclusions We conclude that thermoplastic masks are a viable non-invasive form of primate head restraint that enable a wide range of neuroscientific experiments. PMID:26112334

  17. The Kinesin-5 Chemomechanical Cycle Is Dominated by a Two-heads-bound State*♦

    PubMed Central

    Mickolajczyk, Keith J.

    2016-01-01

    Single-molecule microscopy and stopped-flow kinetics assays were carried out to understand the microtubule polymerase activity of kinesin-5 (Eg5). Four lines of evidence argue that the motor primarily resides in a two-heads-bound (2HB) state. First, upon microtubule binding, dimeric Eg5 releases both bound ADPs. Second, microtubule dissociation in saturating ADP is 20-fold slower for the dimer than for the monomer. Third, ATP-triggered mant-ADP release is 5-fold faster than the stepping rate. Fourth, ATP binding is relatively fast when the motor is locked in a 2HB state. Shortening the neck-linker does not facilitate rear-head detachment, suggesting a minimal role for rear-head-gating. This 2HB state may enable Eg5 to stabilize incoming tubulin at the growing microtubule plus-end. The finding that slowly hydrolyzable ATP analogs trigger slower nucleotide release than ATP suggests that ATP hydrolysis in the bound head precedes stepping by the tethered head, leading to a mechanochemical cycle in which processivity is determined by the race between unbinding of the bound head and attachment of the tethered head. PMID:27402829

  18. Head circumference as a useful surrogate for intracranial volume in older adults.

    PubMed

    Hshieh, Tammy T; Fox, Meaghan L; Kosar, Cyrus M; Cavallari, Michele; Guttmann, Charles R G; Alsop, David; Marcantonio, Edward R; Schmitt, Eva M; Jones, Richard N; Inouye, Sharon K

    2016-01-01

    Intracranial volume (ICV) has been proposed as a measure of maximum lifetime brain size. Accurate ICV measures require neuroimaging which is not always feasible for epidemiologic investigations. We examined head circumference as a useful surrogate for ICV in older adults. 99 older adults underwent Magnetic Resonance Imaging (MRI). ICV was measured by Statistical Parametric Mapping 8 (SPM8) software or Functional MRI of the Brain Software Library (FSL) extraction with manual editing, typically considered the gold standard. Head circumferences were determined using standardized tape measurement. We examined estimated correlation coefficients between head circumference and the two MRI-based ICV measurements. Head circumference and ICV by SPM8 were moderately correlated (overall r = 0.73, men r = 0.67, women r = 0.63). Head circumference and ICV by FSL were also moderately correlated (overall r = 0.69, men r = 0.63, women r = 0.49). Head circumference measurement was strongly correlated with MRI-derived ICV. Our study presents a simple method to approximate ICV among older patients, which may prove useful as a surrogate for cognitive reserve in large scale epidemiologic studies of cognitive outcomes. This study also suggests the stability of head circumference correlation with ICV throughout the lifespan.

  19. DCE: A Distributed Energy-Efficient Clustering Protocol for Wireless Sensor Network Based on Double-Phase Cluster-Head Election.

    PubMed

    Han, Ruisong; Yang, Wei; Wang, Yipeng; You, Kaiming

    2017-05-01

    Clustering is an effective technique used to reduce energy consumption and extend the lifetime of wireless sensor network (WSN). The characteristic of energy heterogeneity of WSNs should be considered when designing clustering protocols. We propose and evaluate a novel distributed energy-efficient clustering protocol called DCE for heterogeneous wireless sensor networks, based on a Double-phase Cluster-head Election scheme. In DCE, the procedure of cluster head election is divided into two phases. In the first phase, tentative cluster heads are elected with the probabilities which are decided by the relative levels of initial and residual energy. Then, in the second phase, the tentative cluster heads are replaced by their cluster members to form the final set of cluster heads if any member in their cluster has more residual energy. Employing two phases for cluster-head election ensures that the nodes with more energy have a higher chance to be cluster heads. Energy consumption is well-distributed in the proposed protocol, and the simulation results show that DCE achieves longer stability periods than other typical clustering protocols in heterogeneous scenarios.

  20. A qualitative systematic review of head-to-head randomized controlled trials of oral analgesics in neuropathic pain

    PubMed Central

    Watson, C Peter N; Gilron, Ian; Sawynok, Jana

    2010-01-01

    BACKGROUND: Neuropathic pain (NP) encompasses many difficult-to-treat disorders. There are few head-to-head, comparative, randomized controlled trials (RCTs) of drugs for NP in different analgesic categories, or of different drugs within a category, despite many placebo-controlled RCTs for individual agents. Well-designed head-to-head comparative trials are an effective way to determine the relative efficacy and safety of a new drug. OBJECTIVE: To perform a systematic review of head-to-head RCTs of oral analgesics in NP. METHODS: A systematic review of RCTs involving NP patients was performed, of which head-to-head comparative trials were selected. Reference lists from published systematic reviews were searched. These studies were rated according to the Jadad scale for quality. RESULTS AND CONCLUSIONS: Twenty-seven such trials were identified. Seventeen were comparisons of different analgesics, and 10 were of different drugs within an analgesic class. Important information was obtained about the relative efficacy and safety of drugs in different categories and within a category. Some significant differences between active treatments were reported. Trial inadequacies were identified. More and improved head-to-head RCTs are needed to inform clinical choices. PMID:20577657

  1. Compact fiber optic gyroscopes for platform stabilization

    NASA Astrophysics Data System (ADS)

    Dickson, William C.; Yee, Ting K.; Coward, James F.; McClaren, Andrew; Pechner, David A.

    2013-09-01

    SA Photonics has developed a family of compact Fiber Optic Gyroscopes (FOGs) for platform stabilization applications. The use of short fiber coils enables the high update rates required for stabilization applications but presents challenges to maintain high performance. We are able to match the performance of much larger FOGs by utilizing several innovative technologies. These technologies include source noise reduction to minimize Angular Random Walk (ARW), advanced digital signal processing that minimizes bias drift at high update rates, and advanced passive thermal packaging that minimizes temperature induced bias drift while not significantly affecting size, weight, or power. In addition, SA Photonics has developed unique distributed FOG packaging technologies allowing the FOG electronics and photonics to be packaged remotely from the sensor head or independent axis heads to minimize size, weight, and power at the sensing location(s). The use of these technologies has resulted in high performance, including ARW less than 0.001 deg/rt-hr and bias drift less than 0.004 deg/hr at an update rate of 10 kHz, and total packaged volume less than 30 cu. in. for a 6 degree of freedom FOG-based IMU. Specific applications include optical beam stabilization for LIDAR and LADAR, beam stabilization for long-range free-space optical communication, Optical Inertial Reference Units for HEL stabilization, and Ka band antenna pedestal pointing and stabilization. The high performance of our FOGs also enables their use in traditional navigation and positioning applications. This paper will review the technologies enabling our high-performance compact FOGs, and will provide performance test results.

  2. Head position of helicopter pilots during slalom maneuvers.

    PubMed

    Temme, Leonard A; Still, David L

    2007-01-01

    Pilots typically tilt their heads when executing coordinated banking turns, a phenomenon commonly attributed to the putative opto-kinetic cervical reflex (OKCR). The OKCR is usually described as a reflex, primarily driven by stimuli in the visual periphery, and is important to a pilot's spatial orientation by providing a relatively stabilized horizontal frame of reference. The present paper presents an alternative hypothesis for the observed head tilting seen in pilots. An archived data set, originally collected for other purposes, contained the head turn, pitch, and tilt of 4 helicopter pilots recorded at 10 Hz as the pilots executed 42 slalom maneuvers in an AH Mk 7 Lynx helicopter under visual flight conditions. The analytic method was a correlational analysis of head turn, pitch, and tilt. As expected, pilots routinely tilted their heads during the slaloms in a fashion typically attributed to the OKCR. Correlations among head turn, tilt, and pitch showed that when the helicopter turned left, the head, presumably to look into the turn, turned left and also pitched up and tilted right. Similarly, when the helicopter turned right, the head, presumably to look into the turn, turned right, pitched up, and tilted left. The head tilting usually attributed to a neuromuscular reflex driven by visual stimuli may be a biomechanical consequence of the head posture pilots assume when they simply look where they are going, eliminating the need to postulate the existence of a novel neuromuscular reflex.

  3. Whiplash-associated disorders affect postural reactions to antero-posterior support surface translations during sitting.

    PubMed

    Côté, Julie N; Patenaude, Isabelle; St-Onge, Nancy; Fung, Joyce

    2009-06-01

    Previous studies have shown that individuals with WAD display decreased postural stability during standing and walking tasks. However, their ability to maintain seated upright posture has never been investigated. The objective of this study was to characterize kinematic and electromyographic postural stabilization patterns in individuals with chronic WAD and to compare these patterns with those in an able-bodied control group. Ten individuals with WAD and an age- and gender-matched group of healthy individuals were exposed to sudden forward and backward support surface translations while they were seated. Neck and trunk muscle activity and angular displacements as well as centers of mass (COMs) linear displacements at four levels of the head and trunk were computed. The displacement onset of the combined head, arms and trunk COM was significantly delayed in persons with WAD. However, their peak trunk angles were smaller and were reached sooner. In the WAD group, the activation onset of the lumbar erector spinae was less affected by perturbation direction and the sternocleidomastoid muscle, a neck flexor, showed a trend towards being activated later, compared to the healthy group. These results suggest that individuals with WAD may alter stretch reflex threshold and/or elicit a learned response for pain avoidance that may be direction-specific. Such findings highlight the importance of assessing both spatial and temporal characteristics across different levels of the spinal musculoskeletal system to evaluate multidirectional postural responses in WAD individuals.

  4. Stability of infinite slopes under transient partially saturated seepage conditions

    NASA Astrophysics Data System (ADS)

    Godt, Jonathan W.; ŞEner-Kaya, BaşAk; Lu, Ning; Baum, Rex L.

    2012-05-01

    Prediction of the location and timing of rainfall-induced shallow landslides is desired by organizations responsible for hazard management and warnings. However, hydrologic and mechanical processes in the vadose zone complicate such predictions. Infiltrating rainfall must typically pass through an unsaturated layer before reaching the irregular and usually discontinuous shallow water table. This process is dynamic and a function of precipitation intensity and duration, the initial moisture conditions and hydrologic properties of the hillside materials, and the geometry, stratigraphy, and vegetation of the hillslope. As a result, pore water pressures, volumetric water content, effective stress, and thus the propensity for landsliding vary over seasonal and shorter time scales. We apply a general framework for assessing the stability of infinite slopes under transient variably saturated conditions. The framework includes profiles of pressure head and volumetric water content combined with a general effective stress for slope stability analysis. The general effective stress, or suction stress, provides a means for rigorous quantification of stress changes due to rainfall and infiltration and thus the analysis of slope stability over the range of volumetric water contents and pressure heads relevant to shallow landslide initiation. We present results using an analytical solution for transient infiltration for a range of soil texture and hydrological properties typical of landslide-prone hillslopes and show the effect of these properties on the timing and depth of slope failure. We follow by analyzing field-monitoring data acquired prior to shallow landslide failure of a hillside near Seattle, Washington, and show that the timing of the slide was predictable using measured pressure head and volumetric water content and show how the approach can be used in a forward manner using a numerical model for transient infiltration.

  5. Characterization of wet aggregate stability of soils by ¹H-NMR relaxometry.

    PubMed

    Buchmann, C; Meyer, M; Schaumann, G E

    2015-09-01

    For the assessment of soil structural stability against hydraulic stress, wet sieving or constant head permeability tests are typically used but rather limited in their intrinsic information value. The multiple applications of several tests is the only possibility to assess important processes and mechanisms during soil aggregate breakdown, e.g. the influences of soil fragment release or differential swelling on the porous systems of soils or soil aggregate columns. Consequently, the development of new techniques for a faster and more detailed wet aggregate stability assessment is required. (1)H nuclear magnetic resonance relaxometry ((1)H-NMR relaxometry) might provide these requirements because it has already been successfully applied on soils. We evaluated the potential of (1)H-NMR relaxometry for the assessment of wet aggregate stability of soils, with more detailed information on occurring mechanisms at the same time. Therefore, we conducted single wet sieving and constant head permeability tests on untreated and 1% polyacrylic acid-treated soil aggregates of different textures and organic matter contents, subsequently measured by (1)H-NMR relaxometry after percolation. The stability of the soil aggregates were mainly depending on their organic matter contents and the type of aggregate stabilization, whereby additional effects of clay swelling on the measured wet aggregate stability were identified by the transverse relaxation time (T2) distributions. Regression analyses showed that only the percentage of water stable aggregates could be determined accurately from percolated soil aggregate columns by (1)H-NMR relaxometry measurements. (1)H-NMR relaxometry seems a promising technique for wet aggregate stability measurements but should be further developed for nonpercolated aggregate columns and real soil samples. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Sensory Interactions for Head and Trunk Control in Space in Young and Older Adults During Normal and Narrow-Base Walking.

    PubMed

    Zhang, Fang; Deshpande, Nandini

    2016-01-01

    Fifteen young (20-30 years old) and 15 older (>65 years old) healthy participants were recruited to investigate age-related differences in head and trunk control under suboptimal vestibular conditions (galvanic vestibular stimulation, or GVS) and vision conditions during normal and narrow-based walking. Head-roll velocity decreased in the blurred-vision condition and marginally increased with GVS in older but not in young participants. Head pitch increased, whereas head-roll velocity decreased in narrow-base walking. Trunk pitch, trunk-pitch velocity, and gait speed increased with GVS, whereas trunk-pitch velocity and gait speed decreased in narrow-base walking. Marginally increased head-roll velocity in the older participants possibly suggests decreased integrative ability of the central nervous system in elderly people. The changes in head control during narrow-base walking may be an attempt to simplify the interpretation of the vestibular signal and increase otolith sensitivity. The complexity of controlling the trunk in the mediolateral direction was suggested by different strategies used for trunk control in different conditions.

  7. Development of An Intelligent Flight Propulsion Control System

    NASA Technical Reports Server (NTRS)

    Calise, A. J.; Rysdyk, R. T.; Leonhardt, B. K.

    1999-01-01

    The initial design and demonstration of an Intelligent Flight Propulsion and Control System (IFPCS) is documented. The design is based on the implementation of a nonlinear adaptive flight control architecture. This initial design of the IFPCS enhances flight safety by using propulsion sources to provide redundancy in flight control. The IFPCS enhances the conventional gain scheduled approach in significant ways: (1) The IFPCS provides a back up flight control system that results in consistent responses over a wide range of unanticipated failures. (2) The IFPCS is applicable to a variety of aircraft models without redesign and,(3) significantly reduces the laborious research and design necessary in a gain scheduled approach. The control augmentation is detailed within an approximate Input-Output Linearization setting. The availability of propulsion only provides two control inputs, symmetric and differential thrust. Earlier Propulsion Control Augmentation (PCA) work performed by NASA provided for a trajectory controller with pilot command input of glidepath and heading. This work is aimed at demonstrating the flexibility of the IFPCS in providing consistency in flying qualities under a variety of failure scenarios. This report documents the initial design phase where propulsion only is used. Results confirm that the engine dynamics and associated hard nonlineaaities result in poor handling qualities at best. However, as demonstrated in simulation, the IFPCS is capable of results similar to the gain scheduled designs of the NASA PCA work. The IFPCS design uses crude estimates of aircraft behaviour. The adaptive control architecture demonstrates robust stability and provides robust performance. In this work, robust stability means that all states, errors, and adaptive parameters remain bounded under a wide class of uncertainties and input and output disturbances. Robust performance is measured in the quality of the tracking. The results demonstrate the flexibility of the IFPCS architecture and the ability to provide robust performance under a broad range of uncertainty. Robust stability is proved using Lyapunov like analysis. Future development of the IFPCS will include integration of conventional control surfaces with the use of propulsion augmentation, and utilization of available lift and drag devices, to demonstrate adaptive control capability under a greater variety of failure scenarios. Further work will specifically address the effects of actuator saturation.

  8. Mandibular deviations in TMD and non-TMD groups related to eye dominance and head posture.

    PubMed

    Pradham, N S; White, G E; Mehta, N; Forgione, A

    2001-01-01

    This study was designed to determine whether eye-dominance affects head posture (rotation) and in turn, whether head posture is associated with mandibular frenum midline deviation, in both TMJ and control subjects. Eye dominance was determined using three tests: Porta, Hole, Point tests. Natural head posture was evaluated using the Arthrodial protractor. Mandibular frenum deviation was recorded as left, right or no deviation. Fifty female subjects were included in the study, 25 TMJ patients attending the Gelb Craniomandibular Pain Center and 25 non-TMJ control subjects. The findings indicate that eye dominance and direction of head rotation are strongly associated in both TMJ and control subjects. Further, in TMJ subjects mandibular deviation occurred in greater frequency than in controls and tends to occur in the contra lateral direction of head rotation.

  9. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    PubMed Central

    2010-01-01

    Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC) and a commercial 8 mm interference screw (Tutofix®). Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121). Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5). Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079) and the 9 mm BC screw (p = 0.0079). Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15). During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the diameter. The safety and in vivo performance of products derived from xenogeneic bone should be the focus of further investigations. PMID:20433761

  10. Blurring the boundaries between frame-based and frameless stereotaxy: feasibility study for brain biopsies performed with the use of a head-mounted robot.

    PubMed

    Grimm, Florian; Naros, Georgios; Gutenberg, Angelika; Keric, Naureen; Giese, Alf; Gharabaghi, Alireza

    2015-09-01

    Frame-based stereotactic interventions are considered the gold standard for brain biopsies, but they have limitations with regard to flexibility and patient comfort because of the bulky head ring attached to the patient. Frameless image guidance systems that use scalp fiducial markers offer more flexibility and patient comfort but provide less stability and accuracy during drilling and biopsy needle positioning. Head-mounted robot-guided biopsies could provide the advantages of these 2 techniques without the downsides. The goal of this study was to evaluate the feasibility and safety of a robotic guidance device, affixed to the patient's skull through a small mounting platform, for use in brain biopsy procedures. This was a retrospective study of 37 consecutive patients who presented with supratentorial lesions and underwent brain biopsy procedures in which a surgical guidance robot was used to determine clinical outcomes and technical procedural operability. The portable head-mounted device was well tolerated by the patients and enabled stable drilling and needle positioning during surgery. Flexible adjustments of predefined paths and selection of new trajectories were successfully performed intraoperatively without the need for manual settings and fixations. The patients experienced no permanent deficits or infections after surgery. The head-mounted robot-guided approach presented here combines the stability of a bone-mounted set-up with the flexibility and tolerability of frameless systems. By reducing human interference (i.e., manual parameter settings, calibrations, and adjustments), this technology might be particularly useful in neurosurgical interventions that necessitate multiple trajectories.

  11. Assessing stability in mild and moderate Parkinson's disease: Can clinical measures provide insight?

    PubMed

    Hubble, Ryan P; Silburn, Peter A; Naughton, Geraldine A; Cole, Michael H

    2016-09-01

    This cross-sectional study aimed to investigate the relationship between accelerometer-derived measures of movement rhythmicity and clinical measures of mobility, balance confidence and gait difficulty in people with Parkinson's disease (PD). Twenty-nine independently-living PD patients (Hoehn & Yahr Stages 1-3) with no history of significant injury or orthopaedic/deep brain stimulation surgery were recruited from a database of patients who had expressed an interest to participate in research. Participants completed clinical assessments of mobility, postural stability, balance confidence and symptom severity, while head and trunk rhythmicity was evaluated during gait using accelerometers. Following data collection, patients were stratified based on disease stage into either a Mild (Hoehn & Yahr Stage 1) or Moderate (Hoehn & Yahr Stages 2-3) PD group. The results highlighted that the Moderate PD group had poorer quality of life, reduced balance confidence and increased gait and falls difficulty. Furthermore, for these patients, gait disability and the number of previous falls were both negatively correlated with multiple components of head and trunk rhythmicity. For the Mild PD group, six-meter walk time was positively correlated with ML head rhythmicity and linear regression highlighted a significant predictive relationship between these outcomes. For the Mild and Moderate PD groups, balance confidence respectively predicted anterior-posterior trunk rhythmicity and vertical head rhythmicity. While these findings demonstrate that falls history and the Gait and Falls questionnaire provide moderate insight into head and trunk rhythmicity in Moderate PD patients, objective and clinically-feasible measures of postural instability would assist with the management of these symptoms. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Emergency Multiengine Aircraft System for Lateral Control Using Differential Thrust Control of Wing Engines

    NASA Technical Reports Server (NTRS)

    Burken, John J. (Inventor); Burcham, Frank W., Jr. (Inventor); Bull, John (Inventor)

    2000-01-01

    Development of an emergency flight control system is disclosed for lateral control using only differential engine thrust modulation of multiengine aircraft is currently underway. The multiengine has at least two engines laterally displaced to the left and right from the axis of the aircraft. In response to a heading angle command psi(sub c) is to be tracked. By continually sensing the heading angle psi of the aircraft and computing a heading error signal psi(sub e) as a function of the difference between the heading angle command psi(sub c) and the sensed heading angle psi, a track control signal is developed with compensation as a function of sensed bank angle phi. Bank angle rate phi, or roll rate p, yaw rate tau, and true velocity produce an aircraft thrust control signal ATC(sub psi(L,R)). The thrust control signal is differentially applied to the left and right engines, with equal amplitude and opposite sign, such that a negative sign is applied to the control signal on the side of the aircraft. A turn is required to reduce the error signal until the heading feedback reduces the error to zero.

  13. Long-Term Effects from Bacterial Meningitis in Childhood and Adolescence on Postural Control

    PubMed Central

    Petersen, Hannes; Patel, Mitesh; Ingason, Einar F.; Einarsson, Einar J.; Haraldsson, Ásgeir; Fransson, Per-Anders

    2014-01-01

    Bacterial meningitis in childhood is associated with cognitive deficiencies, sensorimotor impairments and motor dysfunction later in life. However, the long-term effects on postural control is largely unknown, e.g., whether meningitis subjects as adults fully can utilize visual information and adaptation to enhance stability. Thirty-six subjects (20 women, mean age 19.3 years) treated in childhood or adolescence for bacterial meningitis, and 25 controls (13 women, mean age 25.1 years) performed posturography with eyes open and closed under unperturbed and perturbed standing. The meningitis subjects were screened for subjective vertigo symptoms using a questionnaire, clinically tested with headshake and head thrust test, as well as their hearing was evaluated. Meningitis subjects were significantly more unstable than controls during unperturbed (p≤0.014) and perturbed standing, though while perturbed only with eyes open in anteroposterior direction (p = 0.034) whereas in lateral direction both with eyes open and closed (p<0.001). Meningitis subjects had poorer adaption ability to balance perturbations especially with eyes open, and they frequently reported symptoms of unsteadiness (88% of the subjects) and dizziness (81%), which was found significantly correlated to objectively decreased stability. Out of the 36 subjects only 3 had unilateral hearing impairment. Hence, survivors of childhood bacterial meningitis may suffer long-term disorders affecting postural control, and would greatly benefit if these common late effects became generally known so treatments can be developed and applied. PMID:25405756

  14. The moving minimum audible angle is smaller during self motion than during source motion

    PubMed Central

    Brimijoin, W. Owen; Akeroyd, Michael A.

    2014-01-01

    We are rarely perfectly still: our heads rotate in three axes and move in three dimensions, constantly varying the spectral and binaural cues at the ear drums. In spite of this motion, static sound sources in the world are typically perceived as stable objects. This argues that the auditory system—in a manner not unlike the vestibulo-ocular reflex—works to compensate for self motion and stabilize our sensory representation of the world. We tested a prediction arising from this postulate: that self motion should be processed more accurately than source motion. We used an infrared motion tracking system to measure head angle, and real-time interpolation of head related impulse responses to create “head-stabilized” signals that appeared to remain fixed in space as the head turned. After being presented with pairs of simultaneous signals consisting of a man and a woman speaking a snippet of speech, normal and hearing impaired listeners were asked to report whether the female voice was to the left or the right of the male voice. In this way we measured the moving minimum audible angle (MMAA). This measurement was made while listeners were asked to turn their heads back and forth between ± 15° and the signals were stabilized in space. After this “self-motion” condition we measured MMAA in a second “source-motion” condition when listeners remained still and the virtual locations of the signals were moved using the trajectories from the first condition. For both normal and hearing impaired listeners, we found that the MMAA for signals moving relative to the head was ~1–2° smaller when the movement was the result of self motion than when it was the result of source motion, even though the motion with respect to the head was identical. These results as well as the results of past experiments suggest that spatial processing involves an ongoing and highly accurate comparison of spatial acoustic cues with self-motion cues. PMID:25228856

  15. Effects of Imbalanced Muscle Loading on Hip Joint Development and Maturation

    PubMed Central

    Ford, Caleb A.; Nowlan, Niamh C.; Thomopoulos, Stavros; Killian, Megan L.

    2017-01-01

    The mechanical loading environment influences the development and maturation of joints. In this study, the influence of imbalanced muscular loading on joint development was studied using localized chemical denervation of hip stabilizing muscle groups in neonatal mice. It was hypothesized that imbalanced muscle loading, targeting either gluteal muscles or quadriceps muscles, would lead to bilateral hip joint asymmetry, as measured by acetabular coverage, femoral head volume and bone morphometry, and femoral-acetabular shape. The contralateral hip joints as well as age-matched, uninjected mice were used as controls. Altered bone development was analyzed using micro-computed tomography, histology, and image registration techniques at postnatal days (P) 28, 56, and 120. This study found that unilateral muscle unloading led to reduced acetabular coverage of the femoral head, lower total volume, lower bone volume ratio, and lower mineral density, at all three time points. Histologically, the femoral head was smaller in unloaded hips, with thinner triradiate cartilage at P28 and thinner cortical bone at P120 compared to contralateral hips. Morphological shape changes were evident in unloaded hips at P56. Unloaded hips had lower trabecular thickness and increased trabecular spacing of the femoral head compared to contralateral hips. The present study suggests that decreased muscle loading of the hip leads to altered bone and joint shape and growth during postnatal maturation. Statement of Clinical Significance: Adaptations from altered muscle loading during postnatal growth investigated in this study have implications on developmental hip disorders that result from asymmetric loading, such as patients with limb-length inequality or dysplasia. PMID:27391299

  16. Electrical stimulation of acupuncture points and blood pressure responses to postural changes: a pilot study.

    PubMed

    Jones, Alice Y M; Kwan, Y L; Leung, Nathan T F; Yu, Rachel P W; Wu, Cindy M Y; Warburton, Darren E R

    2011-05-01

    Application of transcutaneous electrical stimulation over acupuncture points (Acu-TENS) facilitates heart rate recovery after exercise and restores hemodynamic stability after open heart surgery. The role of Acu-TENS on cardiovascular parameters in response to postural changes has not been reported. To investigate (1) the effect of Acu-TENS on blood pressure responses to -10º head-down postural change and (2) whether such effects were associated with modulation by the autonomic nervous system. Sixteen healthy volunteers, mean age 22.8 (SD, 3.1) years, were subjected to a -10º head-down tilt from the supine position on 3 separate occasions and received in random order the following 3 intervention protocols for 40 minutes before the postural change: Acu-TENS (over bilateral acupuncture points, PC6), sham-TENS (TENS applied to the skin over the patellae), and control (no electrical output from the TENS device applied at PC6). Mean arterial pressure, large artery elasticity index, cardiac output, and heart rate were recorded and compared at different stimulation protocols in the supine and -10º head-down tilt positions. Spectral analysis of heart rate variability was used to determine any modulation by the autonomic nervous system. Change in large artery elasticity index was observed only in the Acu-TENS group (P < .05) and mean arterial pressure appeared most stable during Acu-TENS. Autonomic nervous system modulation was not apparent with spectral analysis, irrespective of intervention. Sympathetic activity predominated in all positions. Acu-TENS seems to reduce blood pressure changes with -10º head-down tilt with concomitant changes in arterial vessel tone.

  17. A Head Start Control Group. Part of the Final Report.

    ERIC Educational Resources Information Center

    Cunningham, Grover

    A study was conducted to determine if the observed changes in Head Start children were related to the practice effects inherent in a test-retest situation. The "control" group consisted of 64 children who had been eligible for a Head Start program. They roughly matched a group of Head Start (HS) children in IQ scores, age, and…

  18. Inertial vestibular coding of motion: concepts and evidence

    NASA Technical Reports Server (NTRS)

    Hess, B. J.; Angelaki, D. E.

    1997-01-01

    Central processing of inertial sensory information about head attitude and motion in space is crucial for motor control. Vestibular signals are coded relative to a non-inertial system, the head, that is virtually continuously in motion. Evidence for transformation of vestibular signals from head-fixed sensory coordinates to gravity-centered coordinates have been provided by studies of the vestibulo-ocular reflex. The underlying central processing depends on otolith afferent information that needs to be resolved in terms of head translation related inertial forces and head attitude dependent pull of gravity. Theoretical solutions have been suggested, but experimental evidence is still scarce. It appears, along these lines, that gaze control systems are intimately linked to motor control of head attitude and posture.

  19. Distributed and Centralized Conflict Management Under Traffic Flow Management Constraints

    NASA Technical Reports Server (NTRS)

    Feron, Eric; Bilimoria, Karl (Technical Monitor)

    2001-01-01

    The past year's activity has concentrated on the following two activities: (1) Refining and completing our study on the stability of interacting flows of aircraft when they have to resolve conflicts in a decentralized and sequential manner. More specifically, it was felt that some of the modeling assumptions made during previous research (such offset maneuvering models) could be improved to include more realistic models such as heading changes when analyzing interacting flow stability problems. We extended our analysis to achieve this goal. The results of this study have been submitted for presentation at the 2002 American Control Conference; (2) Examining the issues associated with delay propagation across multiple enroute sectors. This study was initiated at NASA in cooperation with Dr. Karl Bilimoria. Considering a set of adjacent sectors, this ongoing study concentrates on the effect of various traffic flow management strategies on the propagation of delays and congestion across sectors. The problem description and findings so far are reported in the attached working paper "Enroute sector buffering capacity."

  20. Non-Agricultural Databases and Thesauri: Retrieval of Subject Headings and Non-Controlled Terms in Relation to Agriculture

    ERIC Educational Resources Information Center

    Bartol, Tomaz

    2012-01-01

    Purpose: The paper aims to assess the utility of non-agriculture-specific information systems, databases, and respective controlled vocabularies (thesauri) in organising and retrieving agricultural information. The purpose is to identify thesaurus-linked tree structures, controlled subject headings/terms (heading words, descriptors), and principal…

  1. Position of the prosthesis and the incidence of dislocation following total hip replacement.

    PubMed

    He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song

    2007-07-05

    Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.

  2. Effectiveness of rugby headgear in preventing soft tissue injuries to the head: a case-control and video cohort study

    PubMed Central

    Jones, S; Lyons, R; Evans, R; Newcombe, R; Nash, P; McCabe, M; Palmer, S

    2004-01-01

    Objective: To determine if headgear use by rugby players was associated with a reduced risk of head or facial laceration, abrasion, or fracture. Methods: An emergency department based case-control study in South Wales, UK, with cases being rugby players treated for superficial head and facial injuries and controls being their matched opponents during the game. A review of videos of the 41 games in the 1999 Rugby World Cup was also carried out to compare with the case-control study. Odds ratios (OR) and 95% confidence intervals (95% CI) were used to measure association between exposure (headgear wearing) and outcome (head and facial injuries). Results: In the case-control study, 164 pairs were analysed, with headgear worn by 12.8% of cases and 21.3% of controls. Headgear use was associated with substantial but non-significant reductions in superficial head (OR = 0.43, 95% CI 0.13 to 1.19) and facial (OR = 0.57, 95% CI 0.21 to 1.46) injuries. The video study followed 547 players over 41 games, during which there were 47 bleeding injuries to the head. Headgear use significantly reduced the risk of bleeding head injury in forwards (OR = 0.14, 95% CI 0.01 to 0.99, p = 0.02), but not in backs. There was also a higher risk of facial injury among forwards, but this was not significant. Conclusions: The combined results suggest that headgear can prevent certain types of superficial head injuries in players at all levels of the game, but the evidence is strongest for superficial head injury in elite forwards. A randomised controlled trial would be the best way to study this further. PMID:15039251

  3. Caudal thoracic air sac cannulation in zebra finches for isoflurane anesthesia.

    PubMed

    Nilson, Paige Crystal; Teramitsu, Ikuko; White, Stephanie Ann

    2005-04-30

    Small songbirds such as the zebra finch are commonly used for studies on the neural mechanisms that underlie vocal learning. For these studies, survival surgeries are often performed that involve animal anesthesia and stereotaxic stabilization for localization of specific brain regions. Here we describe air sac cannulation as a novel method for delivering isoflurane gas to zebra finches for anesthesia during neurosurgery. Advantages of this method include that it leaves the bird's head free for stereotaxic targeting and does not interfere with the beak clamps that are often used to position and stabilize the head. It additionally allows for the use of the inhalant anesthetic, isoflurane, which is an appealing alternative to injectable anesthetics because it provides fast, minimally stressful induction, and low subject and personnel toxicity. The use of isoflurane also prevents overdosing and lengthy postoperative recovery times.

  4. Altered sensory-motor control of the head as an etiological factor in space-motion sickness

    NASA Technical Reports Server (NTRS)

    Lackner, J. R.; DiZio, P.

    1989-01-01

    Mechanical unloading during head movements in weightlessness may be an etiological factor in space-motion sickness. We simulated altered head loading on Earth without affecting vestibular stimulation by having subjects wear a weighted helmet. Eight subjects were exposed to constant velocity rotation about a vertical axis with direction reversals every 60 sec. for eight reversals with the head loaded and eight with the head unloaded. The severity of motion sickness elicited was significantly higher when the head was loaded. This suggests that altered sensory-motor control of the head is also an etiological factor in space-motion sickness.

  5. Biomechanical analysis for primary stability of shoulder arthrodesis in different resection situations.

    PubMed

    Lerch, Solveig; Keller, Sebastian; Kirsch, Ludger; Berndt, Thomas; Rühmann, Oliver

    2013-07-01

    Only very few publications dealing with shoulder arthrodesis after bone resection procedures and no biomechanical studies are available. The presented biomechanical analysis should ascertain the type of arthrodesis with the highest primary stability in different bone loss situations. On 24 fresh cadaveric shoulder specimens three different bone loss situations were investigated under the stress of abduction, adduction, anteversion and retroversion without destruction by the use of a material testing machine. In each of the testings a 16-hole reconstruction plate was used and compared to arthrodesis with an additional dorsal 6-hole plate. The primary stability of shoulder arthrodesis with a 16-hole reconstruction plate after humeral head resection could be increased significantly if an additional dorsal plate was used. However, no significant improvement with the additional plate was detected after resection of the acromion. Of all investigated forms, arthrodesis after humeral head resection with additional plate showed the highest and arthrodesis after humeral head resection without additional plate showed the lowest force values. The mean values for forces achieved in abduction and adduction were considerably higher than those in anteversion and retroversion. There are no consistent specifications of arthrodesis techniques after resection situation available, thus the presented biomechanical testings give important information about the most stable form of arthrodesis in different types of bone loss. These findings provide an opportunity to minimize complications such as pseudarthrosis for a satisfying clinical outcome. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Assisting People with Multiple Disabilities by Actively Keeping the Head in an Upright Position with a Nintendo Wii Remote Controller through the Control of an Environmental Stimulation

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang; Shih, Chia-Ju; Shih, Ching-Tien

    2011-01-01

    The latest researches have adopted software technology by applying the Nintendo Wii Remote Controller to the correction of hyperactive limb behavior. This study extended Wii Remote Controller functionality for improper head position (posture) correction (i.e. actively adjusting abnormal head posture) to assess whether two people with multiple…

  7. Effects of 30-, 60-, and 90-Day Bed Rest on Postural Control in Men and Women

    NASA Technical Reports Server (NTRS)

    Esteves, Julie; Taylor, Laura C.; Vanya, Robert D.; Dean, S. Lance; Wood, Scott J.

    2011-01-01

    INTRODUCTION Head-down-tilt bed rest (HDT) has been used as a safe gr ound-based analog to mimic and develop countermeasures for the physiological effects of spaceflight, including decrements in postural stability. The purpose of this investigation was to characterize the effects of 30-, 60-, and 90-day bed rest on postural control in men and women. METHODS Twenty-nine subjects (18M,11F) underwent 13 days of ambula tory acclimatization and were placed in 6? HDT for 30 (n=12), 60 (n=8), or 90 (n=9) days, followed by 14 days of ambulatory recovery. Computerized dynamic posturography (CDP) was used to assess changes in sensory and motor components of postural control, and recovery after HDT. Sensory Organization Tests (SOTs) objectively evaluate one?s ability to effectively use or suppress visual, vestibular, and proprioceptive information for postural control. Stability during the SOTs was assessed using peak-to-peak sway and convergence toward stability limits to derive an equilibrium score. Motor Control Tests (MCTs) evaluate one?s ability to recover from unexpected support surface perturbations, with performance determined by center-of-pressure path length. Whole-body kinematic data were collected to determine body-sway strategy used to maintain stability during each condition. Baselines were determined pre-HDT. Recovery was tracked post-HDT on days 0, 1, 2, and 4. RESULTS Immediately after HDT, subjects showed decreased performance on most SOTs, primarily on sway-referenced support conditions, typically returning to baseline levels within 4 days. MCT performance was not significantly affected. There were no significant gender or duration differences in performance. Kinematic data revealed a tendency to use ankle strategy to maintain an upright stance during most SOT conditions. Interestingly, six subjects (2M,4F) experienced orthostatic intolerance and were unable to complete day 0 testing. CONCLUSION HDT mimics some un loading mechanisms of spaceflight and elicits orthostatic issues present post-spaceflight (contributing to instability); however, it does not sufficiently address the vestibular dysfunction which occurs post-spaceflight.

  8. Range-Gated Metrology: An Ultra-Compact Sensor for Dimensional Stabilization

    NASA Technical Reports Server (NTRS)

    Lay, Oliver P.; Dubovitsky, Serge; Shaddock, Daniel A.; Ware, Brent; Woodruff, Christopher S.

    2008-01-01

    Point-to-point laser metrology systems can be used to stabilize large structures at the nanometer levels required for precision optical systems. Existing sensors are large and intrusive, however, with optical heads that consist of several optical elements and require multiple optical fiber connections. The use of point-to-point laser metrology has therefore been limited to applications where only a few gauges are needed and there is sufficient space to accommodate them. Range-Gated Metrology is a signal processing technique that preserves nanometer-level or better performance while enabling: (1) a greatly simplified optical head - a single fiber optic collimator - that can be made very compact, and (2) a single optical fiber connection that is readily multiplexed. This combination of features means that it will be straightforward and cost-effective to embed tens or hundreds of compact metrology gauges to stabilize a large structure. In this paper we describe the concept behind Range-Gated Metrology, demonstrate the performance in a laboratory environment, and give examples of how such a sensor system might be deployed.

  9. Airborne Optical Communications Demonstrator Design And Preflight Test Results

    NASA Technical Reports Server (NTRS)

    Biswas, Abhijit; Page, N.; Neal, J.; Zhu, D.; Wright, M.; Ovtiz, G.; Farr, W. H.; Hernnzati, H.

    2005-01-01

    A second generation optical communications demonstrator (OCD-2) intended for airborne applications like air-to-ground and air-to-air optical links is under development at JPL. This development provides the capability for unidirectional high data rate (2.5-Gbps) transmission at 1550-nm, with the ability to receive an 810-nm beacon to aid acquisition pointing and tracking. The transmitted beam width is nominally 200-(micro)rad. A 3x3 degree coarse field-of-view (FOV) acquisition sensor with a much smaller 3-mrad FOV tracking sensor is incorporated. The OCD-2 optical head will be integrated to a high performance gimbal turret assembly capable of providing pointing stability of 5- microradians from an airborne platform. Other parts of OCD-2 include a cable harness, connecting the optical head in the gimbal turret assembly to a rugged electronics box. The electronics box will house: command and control processors, laser transmitter, data-generation-electronics, power conversion/distribution hardware and state-of-health monitors. The entire assembly will be integrated and laboratory tested prior to a planned flight demonstrations.

  10. A high speed, portable, multi-function, weigh-in-motion (WIM) sensing system and a high performance optical fiber Bragg grating (FBG) demodulator

    NASA Astrophysics Data System (ADS)

    Zhang, Hongtao; Wei, Zhanxiong; Fan, Lingling; Yang, Shangming; Wang, Pengfei; Cui, Hong-Liang

    2010-04-01

    A high speed, portable, multi-function WIM sensing system based on Fiber Bragg Grating (FBG) technology is reported in this paper. This system is developed to measure the total weight, the distribution of weight of vehicle in motion, the distance of wheel axles and the distance between left and right wheels. In this system, a temperature control system and a real-time compensation system are employed to eliminate the drifts of optical fiber Fabry-Pérot tunable filter. Carbon Fiber Laminated Composites are used in the sensor heads to obtain high reliability and sensitivity. The speed of tested vehicles is up to 20 mph, the full scope of measurement is 4000 lbs, and the static resolution of sensor head is 20 lbs. The demodulator has high speed (500 Hz) data collection, and high stability. The demodulator and the light source are packed into a 17'' rack style enclosure. The prototype has been tested respectively at Stevens' campus and Army base. Some experiences of avoiding the pitfalls in developing this system are also presented in this paper.

  11. Management of Humeral and Glenoid Bone Loss in Recurrent Glenohumeral Instability

    PubMed Central

    Rusen, Jamie; Leiter, Jeff; Chahal, Jaskarndip; MacDonald, Peter

    2014-01-01

    Recurrent shoulder instability and resultant glenoid and humeral head bone loss are not infrequently encountered in the population today, specifically in young, athletic patients. This review on the management of bone loss in recurrent glenohumeral instability discusses the relevant shoulder anatomy that provides stability to the shoulder joint, relevant history and physical examination findings pertinent to recurrent shoulder instability, and the proper radiological imaging choices in its workup. Operative treatments that can be used to treat both glenoid and humeral head bone loss are outlined. These include coracoid transfer procedures and allograft/autograft reconstruction at the glenoid, as well as humeral head disimpaction/humeroplasty, remplissage, humeral osseous allograft reconstruction, rotational osteotomy, partial humeral head arthroplasty, and hemiarthroplasty on the humeral side. Clinical outcomes studies reporting general results of these techniques are highlighted. PMID:25136461

  12. Integrated multiple-model adaptive fault identification and reconfigurable fault-tolerant control for Lead-Wing close formation systems

    NASA Astrophysics Data System (ADS)

    Liu, Chun; Jiang, Bin; Zhang, Ke

    2018-03-01

    This paper investigates the attitude and position tracking control problem for Lead-Wing close formation systems in the presence of loss of effectiveness and lock-in-place or hardover failure. In close formation flight, Wing unmanned aerial vehicle movements are influenced by vortex effects of the neighbouring Lead unmanned aerial vehicle. This situation allows modelling of aerodynamic coupling vortex-effects and linearisation based on optimal close formation geometry. Linearised Lead-Wing close formation model is transformed into nominal robust H-infinity models with respect to Mach hold, Heading hold, and Altitude hold autopilots; static feedback H-infinity controller is designed to guarantee effective tracking of attitude and position while manoeuvring Lead unmanned aerial vehicle. Based on H-infinity control design, an integrated multiple-model adaptive fault identification and reconfigurable fault-tolerant control scheme is developed to guarantee asymptotic stability of close-loop systems, error signal boundedness, and attitude and position tracking properties. Simulation results for Lead-Wing close formation systems validate the efficiency of the proposed integrated multiple-model adaptive control algorithm.

  13. Personality change following head injury: assessment with the NEO Five-Factor Inventory.

    PubMed

    Lannoo, E; de Deyne, C; Colardyn, F; de Soete, G; Jannes, C

    1997-11-01

    We evaluated personality change following head injury in 68 patients at 6 months postinjury using the NEO Five-Factor Inventory to assess the five personality dimensions of the Five-Factor Model of Personality. All items had to be rated twice, once for the preinjury and once for the current status. Twenty-eight trauma patients with injuries to other parts of the body than the head were used as controls. For the head-injured group, 63 relatives also completed the questionnaire. The results showed no differences between the ratings of head-injured patients and the ratings of trauma control patients. Both groups showed significant change in the personality dimensions Neuroticism, Extraversion, and Conscientiousness. Compared to their relatives, head-injured patients report a smaller change in Extraversion and Conscientiousness. Changes were not reported on the Openness and Agreeableness scales, by neither the head-injured or their relatives, nor by the trauma controls.

  14. Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system.

    PubMed

    Nute, Jessica L; Jacobsen, Megan C; Stefan, Wolfgang; Wei, Wei; Cody, Dianna D

    2018-04-01

    A prototype QC phantom system and analysis process were developed to characterize the spectral capabilities of a fast kV-switching dual-energy computed tomography (DECT) scanner. This work addresses the current lack of quantitative oversight for this technology, with the goal of identifying relevant scan parameters and test metrics instrumental to the development of a dual-energy quality control (DEQC). A prototype elliptical phantom (effective diameter: 35 cm) was designed with multiple material inserts for DECT imaging. Inserts included tissue equivalent and material rods (including iodine and calcium at varying concentrations). The phantom was scanned on a fast kV-switching DECT system using 16 dual-energy acquisitions (CTDIvol range: 10.3-62 mGy) with varying pitch, rotation time, and tube current. The circular head phantom (22 cm diameter) was scanned using a similar protocol (12 acquisitions; CTDIvol range: 36.7-132.6 mGy). All acquisitions were reconstructed at 50, 70, 110, and 140 keV and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy, stability of monoenergetic reconstruction CT number, noise, and positional constancy. Variance component analysis was used to identify technique parameters that drove deviations in test metrics. Variances were compared to thresholds derived from manufacturer tolerances to determine technique parameters that had a nominally significant effect on test metrics. Iodine quantification error was largely unaffected by any of the technique parameters investigated. Monoenergetic HU stability was found to be affected by mAs, with a threshold under which spectral separation was unsuccessful, diminishing the utility of DECT imaging. Noise was found to be affected by CTDIvol in the DEQC body phantom, and CTDIvol and mA in the DEQC head phantom. Positional constancy was found to be affected by mAs in the DEQC body phantom and mA in the DEQC head phantom. A streamlined scan protocol was developed to further investigate the effects of CTDIvol and rotation time while limiting data collection to the DEQC body phantom. Further data collection will be pursued to determine baseline values and statistically based failure thresholds for the validation of long-term DECT scanner performance. © 2018 American Association of Physicists in Medicine.

  15. B-Catenin Stability in Breast Cancer

    DTIC Science & Technology

    1997-07-01

    basic understanding of the cellular processes underlying breast cancer is mandated before effective therapies can be developed or even attempted. P3...Z dorso-anterior body axis, giving rise to two heads, notochords , and neural tubes (24). Wnt-1, dsh dsh hanqgg the vertebrate homologue of wingless is...stability by the ubiquitin-proteasome pathway. The ubiquitin-proteasome pathway is involved in the processing and rapid degradation of many short-lived

  16. Time Counts! Some Comments on System Latency in Head-Referenced Displays

    NASA Technical Reports Server (NTRS)

    Ellis, Stephen R.; Adelstein, Bernard D.

    2013-01-01

    System response latency is a prominent characteristic of human-computer interaction. Laggy systems are; however, not simply annoying but substantially reduce user productivity. The impact of latency on head referenced display systems, particularly head-mounted systems, is especially disturbing since not only can it interfere with dynamic registration in augmented reality displays but it also can in some cases indirectly contribute to motion sickness. We will summarize several experiments using standard psychophysical discrimination techniques that suggest what system latencies will be required to achieve perceptual stability for spatially referenced computer-generated imagery. In conclusion I will speculate about other system performance characteristics that I would hope to have for a dream augmented reality system.

  17. The internal representation of head orientation differs for conscious perception and balance control.

    PubMed

    Dalton, Brian H; Rasman, Brandon G; Inglis, J Timothy; Blouin, Jean-Sébastien

    2017-04-15

    We tested perceived head-on-feet orientation and the direction of vestibular-evoked balance responses in passively and actively held head-turned postures. The direction of vestibular-evoked balance responses was not aligned with perceived head-on-feet orientation while maintaining prolonged passively held head-turned postures. Furthermore, static visual cues of head-on-feet orientation did not update the estimate of head posture for the balance controller. A prolonged actively held head-turned posture did not elicit a rotation in the direction of the vestibular-evoked balance response despite a significant rotation in perceived angular head posture. It is proposed that conscious perception of head posture and the transformation of vestibular signals for standing balance relying on this head posture are not dependent on the same internal representation. Rather, the balance system may operate under its own sensorimotor principles, which are partly independent from perception. Vestibular signals used for balance control must be integrated with other sensorimotor cues to allow transformation of descending signals according to an internal representation of body configuration. We explored two alternative models of sensorimotor integration that propose (1) a single internal representation of head-on-feet orientation is responsible for perceived postural orientation and standing balance or (2) conscious perception and balance control are driven by separate internal representations. During three experiments, participants stood quietly while passively or actively maintaining a prolonged head-turned posture (>10 min). Throughout the trials, participants intermittently reported their perceived head angular position, and subsequently electrical vestibular stimuli were delivered to elicit whole-body balance responses. Visual recalibration of head-on-feet posture was used to determine whether static visual cues are used to update the internal representation of body configuration for perceived orientation and standing balance. All three experiments involved situations in which the vestibular-evoked balance response was not orthogonal to perceived head-on-feet orientation, regardless of the visual information provided. For prolonged head-turned postures, balance responses consistent with actual head-on-feet posture occurred only during the active condition. Our results indicate that conscious perception of head-on-feet posture and vestibular control of balance do not rely on the same internal representation, but instead treat sensorimotor cues in parallel and may arrive at different conclusions regarding head-on-feet posture. The balance system appears to bypass static visual cues of postural orientation and mainly use other sensorimotor signals of head-on-feet position to transform vestibular signals of head motion, a mechanism appropriate for most daily activities. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  18. Locomotor Stability in a Model Swimmer: Coupling Fluid Dynamics, Neurophysiology and Muscle Mechanics

    DTIC Science & Technology

    2017-07-05

    springs which resist deformation. (C) Inset that shows the position of the muscle segments. Cohen, Holmes, Rand, J. Math Biol. 1982 A representative...numbers are the segment number, labeled from head to tail. Cohen, Holmes, Rand, J. Math Biol. 1982 The signals are periodic. Cohen, Holmes, Rand, J... Math Biol. 1982 From head to tail there is a phase lag on each side. Cohen, Holmes, Rand, J. Math Biol. 1982 On a given segment, the signals are in

  19. Cervical kinematic training with and without interactive VR training for chronic neck pain - a randomized clinical trial.

    PubMed

    Sarig Bahat, Hilla; Takasaki, Hiroshi; Chen, Xiaoqi; Bet-Or, Yaheli; Treleaven, Julia

    2015-02-01

    Impairments in cervical kinematics are common in patients with neck pain. A virtual reality (VR) device has potential to be effective in the management of these impairments. The objective of this study was to investigate the effect of kinematic training (KT) with and without the use of an interactive VR device. In this assessor-blinded, allocation-concealed pilot clinical trial, 32 participants with chronic neck pain were randomised into the KT or kinematic plus VR training (KTVR) group. Both groups completed four to six training sessions comprising of similar KT activities such as active and quick head movements and fine head movement control and stability over five weeks. Only the KTVR group used the VR device. The primary outcome measures were neck disability index (NDI), cervical range of motion (ROM), head movement velocity and accuracy. Kinematic measures were collected using the VR system that was also used for training. Secondary measures included pain intensity, TAMPA scale of kinesiophobia, static and dynamic balance, global perceived effect and participant satisfaction. The results demonstrated significant (p < 0.05) improvements in NDI, ROM (rotation), velocity, and the step test in both groups post-intervention. At 3-month post-intervention, these improvements were mostly sustained; however there was no control group, which limits the interpretation of this. Between-group analysis showed a few specific differences including global perceived change that was greater in the KTVR group. This pilot study has provided directions and justification for future research exploring training using kinematic training and VR for those with neck pain in a larger cohort. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Head Circumference as a Useful Surrogate for Intracranial Volume in Older Adults

    PubMed Central

    Hshieh, Tammy T.; Fox, Meaghan L.; Kosar, Cyrus M.; Cavallari, Michele; Guttmann, Charles R.G.; Alsop, David; Marcantonio, Edward R.; Schmitt, Eva M.; Jones, Richard N.; Inouye, Sharon K.

    2015-01-01

    Background Intracranial volume (ICV) has been proposed as a measure of maximum lifetime brain size. Accurate ICV measures require neuroimaging which is not always feasible for epidemiologic investigations. We examined head circumference as a useful surrogate for intracranial volume in older adults. Methods 99 older adults underwent Magnetic Resonance Imaging (MRI). ICV was measured by Statistical Parametric Mapping 8 (SPM8) software or Functional MRI of the Brain Software Library (FSL) extraction with manual editing, typically considered the gold standard. Head circumferences were determined using standardized tape measurement. We examined estimated correlation coefficients between head circumference and the two MRI-based ICV measurements. Results Head circumference and ICV by SPM8 were moderately correlated (overall r=0.73, men r=0.67, women r=0.63). Head circumference and ICV by FSL were also moderately correlated (overall r=0.69, men r=0.63, women r=0.49). Conclusions Head circumference measurement was strongly correlated with MRI-derived ICV. Our study presents a simple method to approximate ICV among older patients, which may prove useful as a surrogate for cognitive reserve in large scale epidemiologic studies of cognitive outcomes. This study also suggests the stability of head circumference correlation with ICV throughout the lifespan. PMID:26631180

  1. The effect of the long head of the biceps on glenohumeral kinematics.

    PubMed

    Youm, Thomas; ElAttrache, Neal S; Tibone, James E; McGarry, Michelle H; Lee, Thay Q

    2009-01-01

    The long head of the biceps has been described as a stabilizing force in the setting of glenohumeral instability. However, data are lacking on the effect of loading the long head of the biceps on glenohumeral kinematics. Six cadaveric shoulders were tested for glenohumeral rotational range of motion and translation using a custom shoulder testing system and the Microscribe 3DLX (Immersion, San Jose, CA). The path of glenohumeral articulation (PGA) was measured by calculating the humeral head center with respect to the glenoid articular surface at maximal internal rotation, 30 degrees, 60 degrees, 90 degrees, and maximal external rotation. Significant decreases in glenohumeral rotational range of motion and translation were found with 22-N biceps loading vs the unloaded group. With respect to the PGA, the humeral rotation center was shifted posterior with biceps loading at maximal internal rotation, 30 degrees, and 60 degrees of external rotation. Loading the long head of the biceps significantly affects glenohumeral rotational range of motion, translations, and kinematics.

  2. Postural orientation and equilibrium: what do we need to know about neural control of balance to prevent falls?

    PubMed

    Horak, Fay B

    2006-09-01

    Postural control is no longer considered simply a summation of static reflexes but, rather, a complex skill based on the interaction of dynamic sensorimotor processes. The two main functional goals of postural behaviour are postural orientation and postural equilibrium. Postural orientation involves the active alignment of the trunk and head with respect to gravity, support surfaces, the visual surround and internal references. Sensory information from somatosensory, vestibular and visual systems is integrated, and the relative weights placed on each of these inputs are dependent on the goals of the movement task and the environmental context. Postural equilibrium involves the coordination of movement strategies to stabilise the centre of body mass during both self-initiated and externally triggered disturbances of stability. The specific response strategy selected depends not only on the characteristics of the external postural displacement but also on the individual's expectations, goals and prior experience. Anticipatory postural adjustments, prior to voluntary limb movement, serve to maintain postural stability by compensating for destabilising forces associated with moving a limb. The amount of cognitive processing required for postural control depends both on the complexity of the postural task and on the capability of the subject's postural control system. The control of posture involves many different underlying physiological systems that can be affected by pathology or sub-clinical constraints. Damage to any of the underlying systems will result in different, context-specific instabilities. The effective rehabilitation of balance to improve mobility and to prevent falls requires a better understanding of the multiple mechanisms underlying postural control.

  3. Evaluation of Learning Associated with Multiple Exposures to Computerized Dynamic Posturography

    NASA Technical Reports Server (NTRS)

    Dean, S. Lance; Paloski, William H.; Taylor, Laura C.; Vanya, Robert D.; Feiveson, Alan H.; Wood, Scott J.

    2009-01-01

    Computerized dynamic posturography has been used to quantitatively assess the time course of functional sensorimotor recovery after exposure to spaceflight or to groundbased analogs such as head-down bed rest. An assessment of balance recovery may be confounded as subjects develop new strategies through repeated exposures to test paradigms. The purpose of this control study was to characterize the learning effects of sensory organization and motor control tests across multiple sessions. METHODS: Twenty-eight healthy subjects were tested over four sessions. To examine the effects of between-session interval, subjects were assigned to one of four groups in which the interval between the 1 st and 2nd sessions was 7 (+/- 1) days, 14 (+/-1) days, 28 (+/-2) days, or 56 (+/-3) days. The interval between remaining sessions was 28 (+/-4) days. Peak-to-peak anterior-posterior sway was measured during standard Sensory Organization Tests (SOTs) using either fixed or unstable sway-referenced support with eyes open, eyes closed, or sway-referenced vision. Sway was also measured during modified SOTs using eyes-closed conditions with either static or dynamic head tilts. Postural recovery to unexpected support surface perturbations (translations or rotations) was measured during Motor Control Tests. The test order was block randomized across subjects. RESULTS: The learning effects varied with test condition. There were no measurable differences with a stable support surface. The more challenging conditions (unstable support surface with and without head tilts) led to greater differences and took more trials to stabilize. The effect of time interval between the first two sessions was negligible across conditions. Evidence suggested that learning carried across similar conditions (such as unstable support SOTs). DISCUSSION: Familiarization session and/or trials are recommended to minimize learning effects when characterizing functional recovery after exposure to altered sensory environments. The number of practice trials required depends on task difficulty and similarity across conditions. Learning statement: This presentation will review the learning effects of computerized d

  4. Trunk sway measures of postural stability during clinical balance tests in patients with chronic whiplash injury symptoms.

    PubMed

    Sjöström, Henrik; Allum, John H J; Carpenter, Mark G; Adkin, Allan L; Honegger, Flurin; Ettlin, Thierry

    2003-08-01

    Trunk sway occurring during clinical stance and gait tasks was compared between a group of subjects with a chronic whiplash injury, resulting from an automobile collision, and a normal collective. To examine if population specific trunk sway patterns for stance and gait could be identified for chronic whiplash injury patients. Our previous work has established that it is possible to identify specific patterns of stance and gait deficits for vestibular loss (both acute and compensated) patients and those with Parkinson's disease. Our question was whether it was possible to use the same stance and gait tasks to identify patterns of trunk sway differences with respect to those of healthy subjects and individuals with a chronic whiplash injury. Twenty-five subjects with history of whiplash injury and 170 healthy age-matched control subjects participated in the study. Trunk sway angular displacements in chronic whiplash patients were assessed for a number of stance and gait tasks similar to those of the Tinetti and Clinical Test of Sensory Interaction and Balance (CTSIB) protocols. We used a lightweight, easy-to-attach, body-worn apparatus to measure trunk angular displacements and velocities in the roll (lateral) and the pitch (forward-backward) planes. Data analysis revealed several significant differences between the two groups. A pattern could be identified, showing greater trunk sway for stance tasks and for complex gait tasks that required task-specific gaze control such as walking up and down stairs. Trunk sway was less, however, for simple gait tasks that demanded large head movements but no task-specific gaze control, such as walking while rotating the head. Subjects who have a chronic whiplash injury show a characteristic pattern of trunk sway that is different from that of other patient groups with balance disorders. Balance was most unstable during gait involving task-specific head movements which possibly enhance a pathologic vestibulo-cervical interaction.

  5. Self-motion perception and vestibulo-ocular reflex during whole body yaw rotation in standing subjects: the role of head position and neck proprioception.

    PubMed

    Panichi, Roberto; Botti, Fabio Massimo; Ferraresi, Aldo; Faralli, Mario; Kyriakareli, Artemis; Schieppati, Marco; Pettorossi, Vito Enrico

    2011-04-01

    Self-motion perception and vestibulo-ocular reflex (VOR) were studied during whole body yaw rotation in the dark at different static head positions. Rotations consisted of four cycles of symmetric sinusoidal and asymmetric oscillations. Self-motion perception was evaluated by measuring the ability of subjects to manually track a static remembered target. VOR was recorded separately and the slow phase eye position (SPEP) was computed. Three different head static yaw deviations (active and passive) relative to the trunk (0°, 45° to right and 45° to left) were examined. Active head deviations had a significant effect during asymmetric oscillation: the movement perception was enhanced when the head was kept turned toward the side of body rotation and decreased in the opposite direction. Conversely, passive head deviations had no effect on movement perception. Further, vibration (100 Hz) of the neck muscles splenius capitis and sternocleidomastoideus remarkably influenced perceived rotation during asymmetric oscillation. On the other hand, SPEP of VOR was modulated by active head deviation, but was not influenced by neck muscle vibration. Through its effects on motion perception and reflex gain, head position improved gaze stability and enhanced self-motion perception in the direction of the head deviation. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Improvement of autonomic nervous regulation by blood purification therapy using acetate-free dialysis fluid - clinical evaluation by laser Doppler flowmetry.

    PubMed

    Sato, Takashi; Taoka, Masahiro; Miyahara, Takaaki

    2011-01-01

    In Japan, acetate-free biofiltration (AFBF) became commercially available in the year 2000, and these products have been reported to be clinically effective for controlling the decrease of blood pressure during dialysis or various types of dialysis intolerance. And more, acetate-free dialysis fluid was made clinically available in 2007, acetate-free hemodialysis (AFHD) is expected to inhibit the malnutrition-inflammation-atherosclerosis syndrome, improve anemia and the nutritional status of patients, stabilize hemodynamics, and reduce inflammation and oxidative stress. In a broad sense, AFBF can be classified as hemodiafiltration (HDF), and its clinical effects seem to be associated with multiple factors, including use of acetate-free dialysis fluid, massive removal of low molecular weight proteins by convection, and the sodium concentration of the replacement fluid. Therefore, the clinical significance of acetate-free dialysis fluid could be demonstrated more clearly by comparing AFHD with conventional hemodialysis (conv. HD) using dialysis fluid containing about 10 mEq/l acetate. Since 2005, we have been investigating the efficacy of various modalities of blood purification therapy by continuously monitoring changes of tissue blood flow in the lower limbs and earlobes (head) using non-invasive continuous monitoring method (NICOMM). In this report, we assess the clinical effectiveness of AFHD on the basis of clinical findings and head stability index (head SI) obtained by NICOMM, particularly with respect to the influence on autonomic regulation. After switching to AFHD from conv. HD, anemia, stored iron utilization, and the frequency of treatments for dialysis hypotension and of muscle cramps were significantly improved. Further, the head SI was also significantly smaller with AFHD than conv. HD. This finding suggests that AFHD improved the maintenance of homeostasis by the autonomic nervous regulation system. In addition, we could not find clinical features of excessive alkalosis during an observation period of about 1 year, even if online HDF using acetate-free dialysis fluid as the substitution fluid. Our conclusion is that the advent of acetate-free dialysis fluid has led to investigations into new clinical effectiveness of AFHD or online HDF/HF using ultrapurified acetate-free dialysis fluid as the substitution fluid. Copyright © 2011 S. Karger AG, Basel.

  7. Effect of antecedent-hydrological conditions on rainfall triggering of debris flows in ash-fall pyroclastic mantled slopes of Campania (southern Italy)

    USGS Publications Warehouse

    Napolitano, E.; Fusco, F; Baum, Rex L.; Godt, Jonathan W.; De Vita, P.

    2016-01-01

    Mountainous areas surrounding the Campanian Plain and the Somma-Vesuvius volcano (southern Italy) are among the most risky areas of Italy due to the repeated occurrence of rainfallinduced debris flows along ash-fall pyroclastic soil-mantled slopes. In this geomorphological framework, rainfall patterns, hydrological processes taking place within multi-layered ash-fall pyroclastic deposits and soil antecedent moisture status are the principal factors to be taken into account to assess triggering rainfall conditions and the related hazard. This paper presents the outcomes of an experimental study based on integrated analyses consisting of the reconstruction of physical models of landslides, in situ hydrological monitoring, and hydrological and slope stability modeling, carried out on four representative source areas of debris flows that occurred in May 1998 in the Sarno Mountain Range. The hydrological monitoring was carried out during 2011 using nests of tensiometers and Watermark pressure head sensors and also through a rainfall and air temperature recording station. Time series of measured pressure head were used to calibrate a hydrological numerical model of the pyroclastic soil mantle for 2011, which was re-run for a 12-year period beginning in 2000, given the availability of rainfall and air temperature monitoring data. Such an approach allowed us to reconstruct the regime of pressure head at a daily time scale for a long period, which is representative of about 11 hydrologic years with different meteorological conditions. Based on this simulated time series, average winter and summer hydrological conditions were chosen to carry out hydrological and stability modeling of sample slopes and to identify Intensity- Duration rainfall thresholds by a deterministic approach. Among principal results, the opposing winter and summer antecedent pressure head (soil moisture) conditions were found to exert a significant control on intensity and duration of rainfall triggering events. Going from winter to summer conditions requires a strong increase of intensity and/or duration to induce landslides. The results identify an approach to account for different hazard conditions related to seasonality of hydrological processes inside the ash-fall pyroclastic soil mantle. Moreover, they highlight another important factor of uncertainty that potentially affects rainfall thresholds triggering shallow landslides reconstructed by empirical approaches.

  8. Automated gantry-type stitching system

    NASA Technical Reports Server (NTRS)

    Thrash, Patrick J. (Inventor); Miller, Jeffrey L. (Inventor); Pallas, Kenneth G. (Inventor); Trank, Robert C. (Inventor); Fox, Rhoda (Inventor); Korte, Mike (Inventor); Codos, Richard (Inventor); Korolev, Aleksandr (Inventor); Collan, William (Inventor)

    1999-01-01

    A stitching system includes a gantry that is movable along a material support table. Mounted to the gantry are a plurality of stitching heads and bobbins. The stitching heads are individually controllable in a z-direction, and the bobbins are individually controllable in the z-direction. Each stitching head is paired with a bobbin. Each pair of stitching heads and the bobbins is controlled synchronously in the z-direction. The stitching system is well-suited for stitching preforms of aircraft wing covers and other preforms having variable thickness and compound, contoured three-dimensional surfaces.

  9. Postural Control Characteristics during Single Leg Standing of Individuals with a History of Ankle Sprain: Measurements Obtained Using a Gravicorder and Head and Foot Accelerometry.

    PubMed

    Abe, Yota; Sugaya, Tomoaki; Sakamoto, Masaaki

    2014-03-01

    [Purpose] This study aimed to validate the postural control characteristics of individuals with a history of ankle sprain during single leg standing by using a gravicorder and head and foot accelerometry. [Subjects] Twenty subjects with and 23 subjects without a history of ankle sprain (sprain and control groups, respectively) participated. [Methods] The anteroposterior, mediolateral, and total path lengths, as well as root mean square (RMS) of each length, were calculated using the gravicorder. The anteroposterior, mediolateral, and resultant acceleration of the head and foot were measured using accelerometers and were evaluated as the ratio of the acceleration of the head to the foot. [Results] There was no significant difference between the two groups in path length or RMS acceleration of the head and foot. However, the ratios of the mediolateral and resultant components were significantly higher in the sprain group than in the control group. [Conclusion] Our findings suggest that individuals with a history of ankle sprain have a higher head-to-foot acceleration ratio and different postural control characteristics than those of control subjects.

  10. A Methodology for Investigating Adaptive Postural Control

    NASA Technical Reports Server (NTRS)

    McDonald, P. V.; Riccio, G. E.

    1999-01-01

    Our research on postural control and human-environment interactions provides an appropriate scientific foundation for understanding the skill of mass handling by astronauts in weightless conditions (e.g., extravehicular activity or EVA). We conducted an investigation of such skills in NASA's principal mass-handling simulator, the Precision Air-Bearing Floor, at the Johnson Space Center. We have studied skilled movement-body within a multidisciplinary context that draws on concepts and methods from biological and behavioral sciences (e.g., psychology, kinesiology and neurophysiology) as well as bioengineering. Our multidisciplinary research has led to the development of measures, for manual interactions between individuals and the substantial environment, that plausibly are observable by human sensory systems. We consider these methods to be the most important general contribution of our EVA investigation. We describe our perspective as control theoretic because it draws more on fundamental concepts about control systems in engineering than it does on working constructs from the subdisciplines of biomechanics and motor control in the bio-behavioral sciences. At the same time, we have attempted to identify the theoretical underpinnings of control-systems engineering that are most relevant to control by human beings. We believe that these underpinnings are implicit in the assumptions that cut across diverse methods in control-systems engineering, especially the various methods associated with "nonlinear control", "fuzzy control," and "adaptive control" in engineering. Our methods are based on these theoretical foundations rather than on the mathematical formalisms that are associated with particular methods in control-systems engineering. The most important aspects of the human-environment interaction in our investigation of mass handling are the functional consequences that body configuration and stability have for the pick up of information or the achievement of overt goals. It follows that an essential characteristic of postural behavior is the effective maintenance of the orientation and stability of the sensory and motor "platforms" (e.g., head or shoulders) over variations in the human, the environment and the task. This general skill suggests that individuals should be sensitive to the functional consequences of body configuration and stability. In other words, individuals should perceive the relation between configuration, stability, and performance so that they can adaptively control their interaction with the surroundings. Human-environment interactions constitute robust systems in that individuals can maintain the stability of such interactions over uncertainty about and variations in the dynamics of the interaction. Robust interactions allow individuals to adopt orientations and configurations that are not optimal with respect to purely energetic criteria. Individuals can tolerate variation in postural states, and such variation can serve an important function in adaptive systems. Postural variability generates stimulation which is "textured" by the dynamics of the human-environment system. The texture or structure in stimulation provides information about variation in dynamics, and such information can be sufficient to guide adaption in control strategies. Our method were designed to measure informative patterns of movement variability.

  11. Comparison of the learning curves of digital examination and transabdominal sonography for the determination of fetal head position during labor.

    PubMed

    Rozenberg, P; Porcher, R; Salomon, L J; Boirot, F; Morin, C; Ville, Y

    2008-03-01

    To evaluate the learning curve of transabdominal sonography for the determination of fetal head position in labor and to compare it with that of digital vaginal examination. A student midwife who had never performed digital vaginal examination or ultrasound examination was recruited for this study. Instructions on how to perform digital vaginal examination and ultrasound examination were given before and after completing the first vaginal and ultrasound examinations, and repeated for each subsequent examination for as long as necessary. Digital and ultrasound diagnoses of the fetal head position were always performed first by the student midwife, and repeated by an experienced midwife or physician. The learning curve for identification of the fetal head position by either one of the two methods was analyzed using the cumulative sums (CUSUM) method for measurement errors. One hundred patients underwent digital vaginal examination and 99 had transabdominal sonography for the determination of fetal head position. An error rate of around 50% for vaginal examination was nearly constant during the first 50 examinations. It decreased subsequently, to stabilize at a low level from the 82(nd) patient. Errors of +/- 180 degrees were the most frequent. The learning curve for ultrasound imaging stabilized earlier than that of vaginal examination, after the 32(nd) patient. The most frequent errors with ultrasound examination were the inability to conclude on a diagnosis, particularly at the beginning of training, followed by errors of +/- 45 degrees. Based on our findings for the student tested, learning and accuracy of the determination of fetal head position in labor were easier and higher, respectively, with transabdominal sonography than with digital examination. This should encourage physicians to introduce clinical ultrasound examination into their practice. CUSUM charts provide a reliable representation of the learning curve, by accumulating evidence of performance. Copyright (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.

  12. Tetra-ataxiometric Posturography in Patients with Migrainous Vertigo.

    PubMed

    Ongun, Nedim; Atalay, Nilgun S; Degirmenci, Eylem; Sahin, Fusun; Bir, Levent Sinan

    2016-01-01

    Migraine is a common disorder characterized by headache attacks frequently accompanied by vestibular symptoms like dizziness, vertigo, and balance disorders. Clinical studies support a strong link between migraine and vertigo rather than between other headache types and vertigo or nonvertiginous dizziness. There is a lack of consensus regarding the pathophysiology of migrainous vertigo. Activation of central vestibular processing during migraine attacks and vasospasm-induced ischemia of the labyrinth are reported as the probable responsible mechanisms. Because vestibular examination alone does not provide enough information for diagnosis of migrainous vertigo, posturography systems which provide objective assessment of somatosensory, vestibular, and visual information would be very helpful to show concomitant involvement of the vestibular and somato-sensorial systems. There are few posturographic studies on patients with migraine but it seems that how balance is affected in patients with migraine and/or migrainous vertigo is still not clear. We want to investigate balance function in migraineurs with and without vertigo with a tetra-ataxiometric posturography system and our study is the first study in which tetra-ataxiometric static posturography was used to evaluate postural abnormalities in a well-defined population of patients with migrainous vertigo. To investigate balance functions in migraineurs with and without vertigo with a tetra-ataxiometric posturography system. Prospective, nonrandomized, controlled study. Pamukkale University Hospital, Neurology and Physical Therapy and Rehabilitation outpatient clinics. Sixteen patients with migrainous vertigo, 16 patients with migraine without aura and no vestibular symptoms, and 16 controls were included in the study. Computerized static posturography system was performed and statistical analyses of fall, Fourier, Stability, and Weight distribution indexes were performed. The tetra-ataxiometric posturography device measures vertical pressure fluctuations on 4 independent stable platforms, each placed beneath 2 heels and toe parts of the patient; inputs from these platforms are integrated and processed by a computer digitally. Four separate plates are used and perpendicular pressures of the anterior and posterior feet are measured. Pressure of each force plate is measured and data was analyzed by the software program. A very small, non-randomized, and controlled study with the inability to find an answer to the mechanism of involvement of the somatosensorial system and vestibular system in migrainous headaches. The distribution of patients with posturographical abnormalities in the migrainous vertigo group was significantly different than the control group. Distribution of the patients with posturographical abnormalities in the high frequencies of the head-right position was significantly different in the migrainous vertigo group than in the control group and distribution of the patients with posturographical abnormalities in high frequencies of the head-right position was significantly different in the migraine group than in the controls groups. The stability index of the migrainous vertigo group was significantly higher than in the control group when tested on in the neutral-head position with open eyes. In this first study of tetra-ataxiometric static posturography evaluating postural abnormalities in a well-defined population of patients with migrainous vertigo, the central part of the vestibular apparatus would be responsible of postural abnormalities in patients with migraine and migrainous vertigo.

  13. Hierarchical control of two-dimensional gaze saccades

    PubMed Central

    Optican, Lance M.; Blohm, Gunnar; Lefèvre, Philippe

    2014-01-01

    Coordinating the movements of different body parts is a challenging process for the central nervous system because of several problems. Four of these main difficulties are: first, moving one part can move others; second, the parts can have different dynamics; third, some parts can have different motor goals; and fourth, some parts may be perturbed by outside forces. Here, we propose a novel approach for the control of linked systems with feedback loops for each part. The proximal parts have separate goals, but critically the most distal part has only the common goal. We apply this new control policy to eye-head coordination in two-dimensions, specifically head-unrestrained gaze saccades. Paradoxically, the hierarchical structure has controllers for the gaze and the head, but not for the eye (the most distal part). Our simulations demonstrate that the proposed control structure reproduces much of the published empirical data about gaze movements, e.g., it compensates for perturbations, accurately reaches goals for gaze and head from arbitrary initial positions, simulates the nine relationships of the head-unrestrained main sequence, and reproduces observations from lesion and single-unit recording experiments. We conclude by showing how our model can be easily extended to control structures with more linked segments, such as the control of coordinated eye on head on trunk movements. PMID:24062206

  14. A head movement image (HMI)-controlled computer mouse for people with disabilities.

    PubMed

    Chen, Yu-Luen; Chen, Weoi-Luen; Kuo, Te-Son; Lai, Jin-Shin

    2003-02-04

    This study proposes image processing and microprocessor technology for use in developing a head movement image (HMI)-controlled computer mouse system for the spinal cord injured (SCI). The system controls the movement and direction of the mouse cursor by capturing head movement images using a marker installed on the user's headset. In the clinical trial, this new mouse system was compared with an infrared-controlled mouse system on various tasks with nine subjects with SCI. The results were favourable to the new mouse system. The differences between the new mouse system and the infrared-controlled mouse were reaching statistical significance in each of the test situations (p<0.05). The HMI-controlled computer mouse improves the input speed. People with disabilities need only wear the headset and move their heads to freely control the movement of the mouse cursor.

  15. Microencapsulation of Ascorbic Acid for Enhanced Long-term Retention during Storage

    DTIC Science & Technology

    2011-01-01

    in fortified instant Asian noodles by use of capillary electrophoresis. Food Chemistry 112(2): 507–514. Hau Fung Cheung, R., Marriott, P.J . and...D., Small, D. M. and Marriott, P. J. (2008). Investigation of folic acid stability in fortified instant noodles by use of capillary electrophoresis...processing and preparation of instant Asian noodles . PhD thesis, RMIT University: Melbourne. Head, M.K. and Hansen, A.P. (1979). Stability of L

  16. Polyethylene versus cotton cap as an adjunct to body wrap in preterm infants.

    PubMed

    Shafie, Hashim; Syed Zakaria, Syed Zulkifli; Adli, Ali; Shareena, Ishak; Rohana, Jaafar

    2017-07-01

    Occlusive body wrap using polyethylene plastic applied immediately after birth had been shown to reduce hypothermia among preterm infants. Various adjunct methods have been studied in an attempt to further reduce the incidence of hypothermia. This study was conducted to determine whether polyethylene cap is more effective than cotton cap as an adjunct to polyethylene occlusive body wrap in reducing hypothermia in preterm infants. The subjects consisted of preterm infants 24-34 weeks' gestation born at Universiti Kebangsaan Malaysia Medical Centre. Infants were randomly assigned to NeoCap or control groups. Infants in both groups were wrapped in polyethylene sheets from the neck downwards immediately after birth without prior drying. Infants in the control group had their heads dried and subsequently covered with cotton caps while infants in the NeoCap group had polyethylene caps put on without drying. Axillary temperature was measured on admission to the neonatal intensive care unit (NICU), and after having been stabilized in the incubator. Among the 80 infants recruited, admission hypothermia (axillary temperature <36.5°C) was present in 37 (92.5%) and in 40 (100%) in the NeoCap and control groups, respectively. There was no significant difference in mean temperature on NICU admission between the two groups (35.3 vs 35.1°C, P = 0.36). Mean post-stabilization temperature, however, was significantly higher in the NeoCap group (36.0 vs 35.5°C, P = 0.01). Combined use of polyethylene body wrap and polyethylene cap was associated with a significantly higher mean post-stabilization temperature compared with polyethylene body wrap and cotton cap. © 2017 Japan Pediatric Society.

  17. Star-coupled Hindmarsh-Rose neural network with chemical synapses

    NASA Astrophysics Data System (ADS)

    Usha, K.; Subha, P. A.

    We analyze the patterns like synchrony, desynchrony, and Drum head mode in a network of Hindmarsh-Rose (HR) neurons interacting via chemical synapse in unidirectional and bidirectional star topology. A two-coupled system has been studied for synchronization by varying the coupling strength and the parameter describing the activation and inactivation of the fast ion channel. The transverse Lyapunov exponent spectrum is plotted to observe the point of transition from desynchrony to synchrony. The synchronized, desynchronized, and drum head mode regions are observed when the neurons are connected in unidirectional and bidirectional coupling configurations. A detailed analysis about the time evolution of membrane potential corresponding to each region is presented. The annihilation of synchronized region and the expansion of drum head mode region in bidirectional coupling is discussed using parameter space. Our work provides finer insight into the existence and stability of Drum head mode and is useful for designing communication networks.

  18. Cellular resolution functional imaging in behaving rats using voluntary head restraint

    PubMed Central

    Scott, Benjamin B.; Brody, Carlos D.; Tank, David W.

    2013-01-01

    SUMMARY High-throughput operant conditioning systems for rodents provide efficient training on sophisticated behavioral tasks. Combining these systems with technologies for cellular resolution functional imaging would provide a powerful approach to study neural dynamics during behavior. Here we describe an integrated two-photon microscope and behavioral apparatus that allows cellular resolution functional imaging of cortical regions during epochs of voluntary head restraint. Rats were trained to initiate periods of restraint up to 8 seconds in duration, which provided the mechanical stability necessary for in vivo imaging while allowing free movement between behavioral trials. A mechanical registration system repositioned the head to within a few microns, allowing the same neuronal populations to be imaged on each trial. In proof-of-principle experiments, calcium dependent fluorescence transients were recorded from GCaMP-labeled cortical neurons. In contrast to previous methods for head restraint, this system can also be incorporated into high-throughput operant conditioning systems. PMID:24055015

  19. Intersegmental Eye-Head-Body Interactions during Complex Whole Body Movements

    PubMed Central

    von Laßberg, Christoph; Beykirch, Karl A.; Mohler, Betty J.; Bülthoff, Heinrich H.

    2014-01-01

    Using state-of-the-art technology, interactions of eye, head and intersegmental body movements were analyzed for the first time during multiple twisting somersaults of high-level gymnasts. With this aim, we used a unique combination of a 16-channel infrared kinemetric system; a three-dimensional video kinemetric system; wireless electromyography; and a specialized wireless sport-video-oculography system, which was able to capture and calculate precise oculomotor data under conditions of rapid multiaxial acceleration. All data were synchronized and integrated in a multimodal software tool for three-dimensional analysis. During specific phases of the recorded movements, a previously unknown eye-head-body interaction was observed. The phenomenon was marked by a prolonged and complete suppression of gaze-stabilizing eye movements, in favor of a tight coupling with the head, spine and joint movements of the gymnasts. Potential reasons for these observations are discussed with regard to earlier findings and integrated within a functional model. PMID:24763143

  20. Comparison of three different techniques for camera and motion control of a teleoperated robot.

    PubMed

    Doisy, Guillaume; Ronen, Adi; Edan, Yael

    2017-01-01

    This research aims to evaluate new methods for robot motion control and camera orientation control through the operator's head orientation in robot teleoperation tasks. Specifically, the use of head-tracking in a non-invasive way, without immersive virtual reality devices was combined and compared with classical control modes for robot movements and camera control. Three control conditions were tested: 1) a condition with classical joystick control of both the movements of the robot and the robot camera, 2) a condition where the robot movements were controlled by a joystick and the robot camera was controlled by the user head orientation, and 3) a condition where the movements of the robot were controlled by hand gestures and the robot camera was controlled by the user head orientation. Performance, workload metrics and their evolution as the participants gained experience with the system were evaluated in a series of experiments: for each participant, the metrics were recorded during four successive similar trials. Results shows that the concept of robot camera control by user head orientation has the potential of improving the intuitiveness of robot teleoperation interfaces, specifically for novice users. However, more development is needed to reach a margin of progression comparable to a classical joystick interface. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Hummingbird flight stability and control in freestream turbulent winds.

    PubMed

    Ravi, Sridhar; Crall, James D; McNeilly, Lucas; Gagliardi, Susan F; Biewener, Andrew A; Combes, Stacey A

    2015-05-01

    Airflow conditions close to the Earth's surface are often complex, posing challenges to flight stability and control for volant taxa. Relatively little is known about how well flying animals can contend with complex, adverse air flows, or about the flight control mechanisms used by animals to mitigate wind disturbances. Several recent studies have examined flight in the unsteady von Kármán vortex streets that form behind cylinders, generating flow disturbances that are predictable in space and time; these structures are relatively rare in nature, because they occur only the immediate, downstream vicinity of an object. In contrast, freestream turbulence is characterized by rapid, unpredictable flow disturbances across a wide range of spatial and temporal scales, and is nearly ubiquitous in natural habitats. Hummingbirds are ideal organisms for studying the influence of freestream turbulence on flight, as they forage in a variety of aerial conditions and are powerful flyers. We filmed ruby-throated hummingbirds (Archilochus colubris) maintaining position at a feeder in laminar and strongly turbulent (intensity ∼15%) airflow environments within a wind tunnel and compared their mean kinematics of the head, body, tail and wing, as well as variability in these parameters. Hummingbirds exhibited remarkably stable head position and orientation in both smooth and turbulent flow while maintaining position at the feeder. However, the hummingbird's body was less stable in turbulent flow and appeared to be most sensitive to disturbances along the mediolateral axis, displaying large lateral accelerations, translations and rolling motions during flight. The hummingbirds mitigated these disturbances by increasing mean wing stroke amplitude and stroke plane angle, and by varying these parameters asymmetrically between the wings and from one stroke to the next. They also actively varied the orientation and fan angle of the tail, maintaining a larger mean fan angle when flying in turbulent flow; this may improve their passive stability, but probably incurs an energetic cost as a result of increased drag. Overall, we observed many of the same kinematic changes noted previously for hummingbirds flying in a von Kármán vortex street, but we also observed kinematic changes associated with high force production, similar to those seen during load-lifting or high-speed flight. These findings suggest that flight may be particularly costly in fully mixed, freestream turbulence, which is the flow condition that hummingbirds are likely to encounter most frequently in natural habitats. © 2015. Published by The Company of Biologists Ltd.

  2. The Influence of Head Motion on Intrinsic Functional Connectivity MRI

    PubMed Central

    Van Dijk, Koene R.A.; Sabuncu, Mert R.; Buckner, Randy L.

    2011-01-01

    Functional connectivity MRI (fcMRI) has been widely applied to explore group and individual differences. A confounding factor is head motion. Children move more than adults, older adults more than younger adults, and patients more than controls. Head motion varies considerably among individuals within the same population. Here we explored the influence of head motion on fcMRI estimates. Mean head displacement, maximum head displacement, the number of micro movements (> 0.1 mm), and head rotation were estimated in 1000 healthy, young adult subjects each scanned for two resting-state runs on matched 3T scanners. The majority of fcMRI variation across subjects was not linked to estimated head motion. However, head motion had significant, systematic effects on fcMRI network measures. Head motion was associated with decreased functional coupling in the default and frontoparietal control networks – two networks characterized by coupling among distributed regions of association cortex. Other network measures increased with motion including estimates of local functional coupling and coupling between left and right motor regions – a region pair sometimes used as a control in studies to establish specificity. Comparisons between groups of individuals with subtly different levels of head motion yielded difference maps that could be mistaken for neuronal effects in other contexts. These effects are important to consider when interpreting variation between groups and across individuals. PMID:21810475

  3. Bioinspired optical sensors for unmanned aerial systems

    NASA Astrophysics Data System (ADS)

    Chahl, Javaan; Rosser, Kent; Mizutani, Akiko

    2011-04-01

    Insects are dependant on the spatial, spectral and temporal distributions of light in the environment for flight control and navigation. This paper reports on flight trials of implementations of insect inspired behaviors on unmanned aerial vehicles. Optical flow methods for maintaining a constant height above ground and a constant course have been demonstrated to provide navigation capabilities that are impossible using conventional avionics sensors. Precision control of height above ground and ground course were achieved over long distances. Other vision based techniques demonstrated include a biomimetic stabilization sensor that uses the ultraviolet and green bands of the spectrum, and a sky polarization compass. Both of these sensors were tested over long trajectories in different directions, in each case showing performance similar to low cost inertial heading and attitude systems. The behaviors demonstrate some of the core functionality found in the lower levels of the sensorimotor system of flying insects and shows promise for more integrated solutions in the future.

  4. The influence of L-acetylcarnitine on reinnervation of the oculomotor nerve.

    PubMed

    Pettorossi, V E; Draicchio, F; Fernandez, E; Pallini, R

    1993-01-01

    In guinea-pigs the oral administration of L-acetylcarnitine (L-AC) markedly favours the process of reinnervation of the oculomotor nerve sectioned at intracranial level. The gains of the horizontal and vertical vestibulo-ocular reflexes (HVOR, VVOR) were taken into consideration in testing the functional recovery of the nerve. As a consequence of the drug administration, 24 weeks after the operation the gains of the treated animals were higher than those of the controls. Reduction of misalignments of the stimulus-response orientation was also observed in treated animals as compared to the controls. This suggests that L-AC potentiates motor reinnervation by enhancing the nerve-growing processes and favouring a better consolidation of the appropriate neuromuscular synapses. The increased gain, and the improvement of the alignment in ocular responses, due to L-AC would allow for an increase of visual function during head movement by optimizing gaze stability.

  5. Stability of cervical spine fractures after gunshot wounds to the head and neck.

    PubMed

    Medzon, Ron; Rothenhaus, Todd; Bono, Christopher M; Grindlinger, Gene; Rathlev, Niels K

    2005-10-15

    Retrospective chart review. To determine the frequency of stable and unstable cervical spine fractures after gunshot wounds to the head or neck; to identify potential risk factor(s) for an unstable versus stable cervical spine fracture. Cervical spine fractures after gunshot wounds to the head and neck are common. Because of the nature of their injuries, patients often present with concomitant airway obstruction and large blood vessel injury that can necessitate emergent procedures. In some cases, acute treatment of these problems can be hindered by the presence of a cervical collar or strict adherence to spinal precautions (i.e., patient laying supine). In such situations, information regarding the probability of a stable versus unstable cervical spine fracture would be useful in emergency treatment decision making. A search for patients with gunshot wounds to the head or neck potentially involving the cervical spine over a 13-year period was performed using a trauma registry. Individuals with cervical spine fractures were identified and their records reviewed in detail. Data collected included information about neurologic deficits, mental status, airway treatment, entrance wounds, fracture level/type, initial/definitive fracture treatment, and final disposition at hospital discharge. A total of 81 patients were identified; 19 had cervical spine fractures. There were 5 patients who were not examinable because of altered mental status (severe head trauma, hemorrhagic shock, or intoxication). All 5 patients had stable cervical spine fractures. There were 11 patients who had an acute spinal cord injury, 3 (30%) of whom underwent surgery for an unstable fracture. Of the 65 awake, alert patients without a neurologic deficit, only 3 (5%) had a fracture, none of which were unstable. Gunshot wounds to the head and neck had a high rate of concomitant cervical spine fracture. Neurologically intact patients have a lower rate of fracture than those presenting with a spinal cord injury or altered mental status. In this small series of patients, the only unstable cervical spine injuries were detected in patients with a spinal cord injury. The data suggest that spinal precautions and/or a hard cervical collar should not be maintained at the expense of delaying or hindering emergent life-saving airway or hemodynamically stabilizing procedures, particularly in awake, neurologically intact patients. However, the cervical collar and spinal precautions should be resumed after such procedures are completed and continued until a more definitive evaluation of spinal stability can be performed.

  6. Emergence of postural patterns as a function of vision and translation frequency

    NASA Technical Reports Server (NTRS)

    Buchanan, J. J.; Horak, F. B.; Peterson, B. W. (Principal Investigator)

    1999-01-01

    Emergence of postural patterns as a function of vision and translation frequency. We examined the frequency characteristics of human postural coordination and the role of visual information in this coordination. Eight healthy adults maintained balance in stance during sinusoidal support surface translations (12 cm peak to peak) in the anterior-posterior direction at six different frequencies. Changes in kinematic and dynamic measures revealed that both sensory and biomechanical constraints limit postural coordination patterns as a function of translation frequency. At slow frequencies (0.1 and 0.25 Hz), subjects ride the platform (with the eyes open or closed). For fast frequencies (1.0 and 1.25 Hz) with the eyes open, subjects fix their head and upper trunk in space. With the eyes closed, large-amplitude, slow-sway motion of the head and trunk occurred for fast frequencies above 0.5 Hz. Visual information stabilized posture by reducing the variability of the head's position in space and the position of the center of mass (CoM) within the support surface defined by the feet for all but the slowest translation frequencies. When subjects rode the platform, there was little oscillatory joint motion, with muscle activity limited mostly to the ankles. To support the head fixed in space and slow-sway postural patterns, subjects produced stable interjoint hip and ankle joint coordination patterns. This increase in joint motion of the lower body dissipated the energy input by fast translation frequencies and facilitated the control of upper body motion. CoM amplitude decreased with increasing translation frequency, whereas the center of pressure amplitude increased with increasing translation frequency. Our results suggest that visual information was important to maintaining a fixed position of the head and trunk in space, whereas proprioceptive information was sufficient to produce stable coordinative patterns between the support surface and legs. The CNS organizes postural patterns in this balance task as a function of available sensory information, biomechanical constraints, and translation frequency.

  7. Current and Future Management of Bilateral Loss of Vestibular Sensation – An update on the Johns Hopkins Multichannel Vestibular Prosthesis Project

    PubMed Central

    Della Santina, Charles C.; Migliaccio, Americo A.; Hayden, Russell; Melvin, Thuy-Anh; Fridman, Gene Y.; Chiang, Bryce; Davidovics, Natan S.; Dai, Chenkai; Carey, John P.; Minor, Lloyd B.; Anderson, Iee-Ching; Park, HongJu; Lyford-Pike, Sofia; Tang, Shan

    2012-01-01

    Bilateral loss of vestibular sensation can disable individuals whose vestibular hair cells are injured by ototoxic medications, infection, Ménière’s disease or other insults to the labyrinth including surgical trauma during cochlear implantation. Without input to vestibulo-ocular and vestibulo-spinal reflexes that normally stabilize the eyes and body, affected patients suffer blurred vision during head movement, postural instability, and chronic disequilibrium. While individuals with some residual sensation often compensate for their loss through rehabilitation exercises, those who fail to do so are left with no adequate treatment options. An implantable neuroelectronic vestibular prosthesis that emulates the normal labyrinth by sensing head movement and modulating activity on appropriate branches of the vestibular nerve could significantly improve quality of life for these otherwise chronically dizzy patients. This brief review describes the impact and current management of bilateral loss of vestibular sensation, animal studies supporting the feasibility of prosthetic vestibular stimulation, and a vestibular prosthesis designed to restore sensation of head rotation in all directions. Similar to a cochlear implant in concept and size, the Johns Hopkins Multichannel Vestibular Prosthesis (MVP) includes miniature gyroscopes to sense head rotation, a microcontroller to process inputs and control stimulus timing, and current sources switched between pairs of electrodes implanted within the vestibular labyrinth. In rodents and rhesus monkeys rendered bilaterally vestibular-deficient via treatment with gentamicin and/or plugging of semicircular canals, the MVP partially restores the vestibulo-ocular reflex for head rotations about any axis of rotation in 3-dimensional space. Our efforts now focus on addressing issues prerequisite to human implantation, including refinement of electrode designs and surgical technique to enhance stimulus selectivity and preserve cochlear function, optimization of stimulus protocols, and reduction of device size and power consumption. PMID:21756683

  8. Neural Correlates of Sensory Substitution in Vestibular Pathways Following Complete Vestibular Loss

    PubMed Central

    Sadeghi, Soroush G.; Minor, Lloyd B.; Cullen, Kathleen E.

    2012-01-01

    Sensory substitution is the term typically used in reference to sensory prosthetic devices designed to replace input from one defective modality with input from another modality. Such devices allow an alternative encoding of sensory information that is no longer directly provided by the defective modality in a purposeful and goal-directed manner. The behavioral recovery that follows complete vestibular loss is impressive and has long been thought to take advantage of a natural form of sensory substitution in which head motion information is no longer provided by vestibular inputs, but instead by extra-vestibular inputs such as proprioceptive and motor efference copy signals. Here we examined the neuronal correlates of this behavioral recovery after complete vestibular loss in alert behaving monkeys (Macaca mulata). We show for the first time that extra-vestibular inputs substitute for the vestibular inputs to stabilize gaze at the level of single neurons in the VOR premotor circuitry. The summed weighting of neck proprioceptive and efference copy information was sufficient to explain simultaneously observed behavioral improvements in gaze stability. Furthermore, by altering correspondence between intended and actual head movement we revealed a four-fold increase in the weight of neck motor efference copy signals consistent with the enhanced behavioral recovery observed when head movements are voluntary versus unexpected. Thus, taken together our results provide direct evidence that the substitution by extra-vestibular inputs in vestibular pathways provides a neural correlate for the improvements in gaze stability that are observed following the total loss of vestibular inputs. PMID:23077054

  9. Comanche Helmet-Mounted Display Heading-Tape Simulation

    NASA Technical Reports Server (NTRS)

    Turpin, Terry; Dowell, Susan; Atencio, Adolph

    2006-01-01

    The Aeroflightdynamics Directorate (AMRDEC) conducted a simulation to assess the performance associated with a Contact Analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a Compressed heading tape similar to that specified by the former Military Standard (MIL-STD) 1295. Six experienced pilots flew three modified Aeronautical Design Standards (ADS)-33 maneuvers (Hover Turn, Bob-up, Transient Turn) and a precision traffic pattern in the NASA Vertical Motion Simulator (VMS). Analysis of the pilot objective performance data and subjective handling qualities ratings (HQRs) showed the following: Compressed symbology in the Velocity Stabilization (VelStab) flight mode generally produced the most precise performances over Contact Analog symbology with respect to the heading, altitude, position, and time criteria specified for the maneuvers tested. VelStab outperformed the Automatic Flight Control System (AFCS) on all maneuvers achieving desired performance on most maneuvers for both symbol sets. Performance in the AFCS mode was generally desirable to adequate for heading and altitude and did not meet adequate standards for hover position and time for the Hover Turn and Bob-up maneuvers. VelStab and AFCS performance were nearly the same for the Transient Turn. Pilot comments concerning the Contact Analog heading-tape implementation were generally unfavorable in spite of the achieved levels of performance. HQRs showed Compressed symbology in the VelStab flight mode produced the lowest mean HQR, encompassing mixed ratings of satisfactory handling and needing improvement. All other symbology/flight-mode combinations yielded higher HQRs, which characterized opinions that deficiencies in aircraft handling due to HMD symbology would need improvement. Contact Analog heading tape and other symbology require improvement, especially when operating in the AFCS mode. NASA-TLX rated Compressed symbology in the VelStab flight mode as the least demanding on resources, closely followed by ratings for Contact Analog in the VelStab mode. In a similar pattern, TLX ratings for maneuvers completed in the AFCS mode yielded a higher level of resource demand with even slighter differences between Contact Analog and Compressed symbology sets. Further research should be conducted where objective data and subjective HQR ratings indicate a need for improvement. The areas requiring attention are those where the symbology implementation, the flight control system, or a combination of both caused workload to reach an objectionable level where adequate performance was either difficult to achieve or unachievable. These areas are clearly identified in this report. Symbology that received negative HQR comments by a majority of pilots should also be examined. The summary of pilot comments can be found in appendix A. Additional simulation trials should be considered to address the identified issues.

  10. A recombinant tail-less integrin beta 4 subunit disrupts hemidesmosomes, but does not suppress alpha 6 beta 4-mediated cell adhesion to laminins

    PubMed Central

    1995-01-01

    To examine the function of the alpha 6 beta 4 integrin we have determined its ligand-binding ability and overexpressed two potentially dominant negative mutant beta 4 subunits, lacking either the cytoplasmic or extracellular domain, in bladder epithelial 804G cells. The results of cell adhesion and radioligand-binding assays showed that alpha 6 beta 4 is a receptor for several laminin isoforms, including laminin 1, 2, 4, and 5. Overexpression of the tail-less or head-less mutant beta 4 subunit did not suppress alpha 6 beta 4-mediated adhesion to laminins, as both types of transfectants adhered to these ligands in the presence of blocking anti-beta 1 antibodies as well as the controls. However, immunofluorescence experiments indicated that the endogenous alpha 6 beta 4 integrin and other hemidesmosomal markers were not concentrated in hemidesmosomes in cells overexpressing tail- less beta 4, while the distribution of these molecules was not altered in cells overexpressing the head-less subunit. Electron microscopic studies confirmed that cells overexpressing tail-less beta 4 had a drastically reduced number of hemidesmosomes, while cells expressing the head-less subunit had a normal number of these structures. Thus, expression of a tail-less, but not a head-less mutant beta 4 subunit leads to a dominant negative effect on hemidesmosome assembly without suppressing initial adhesion to laminins. We conclude that the alpha 6 beta 4 integrin binds to several laminins and plays an essential role in the assembly and/or stability of hemidesmosomes, that alpha 6 beta 4- mediated adhesion and hemidesmosome assembly have distinct requirements, and that it is possible to use a dominant negative approach to selectively interfere with a specific function of an integrin. PMID:7721947

  11. Tau protein (MAPT) as a possible biochemical marker of traumatic brain injury in postmortem examination.

    PubMed

    Olczak, Mieszko; Niderla-Bielińska, Justyna; Kwiatkowska, Magdalena; Samojłowicz, Dorota; Tarka, Sylwia; Wierzba-Bobrowicz, Teresa

    2017-11-01

    MAPT is a neuronal protein that plays an important role in axonal stabilization, neuronal development, and neuronal polarity. MAPT release into the CSF and blood has been interpreted as indicative of axonal injury as its elevated levels were observed in olympic boxers even after a mild head trauma suggesting minor CNS injuries. In our study we wanted to check the potential relevance of MAPT examination for forensic purposes. The study was carried out using cases of head injury group and cases of sudden death (cardiopulmonary failure, no injuries of the head - control group) provided by forensic pathologists at the Department of Forensic Medicine, Medical University of Warsaw. CSF and blood were collected within 24h after death using suboccipital puncture and femoral vein puncture. Serum and cerebrospinal fluid Tau protein concentrations were compared using an enzyme-linked immunosorbent assay (elisa). Brain specimens (frontal cortex) were collected during forensic autopsies. Sections were stained histologically (hematoxylin-eosin) and immunohistochemically with anti human Tau antibody, anti glial fibrillary acid protein (GFAP), anti human macrosialin (CD68) or anti human endothelial cells (CD34). In our study we documented that elevated levels of serum and CSF MAPT may also be considered a marker for mild traumatic brain injury and traumatic brain injury (mTBI and TBI). An increase in CSF and serum levels of MAPT in the absence of visible macroscopic traumatic CNS changes indicates that even minor head injuries may result in changes at the neuronal level that could remain undiagnosed during regular forensic autopsy and routine histopathological examination. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Effects of imbalanced muscle loading on hip joint development and maturation.

    PubMed

    Ford, Caleb A; Nowlan, Niamh C; Thomopoulos, Stavros; Killian, Megan L

    2017-05-01

    The mechanical loading environment influences the development and maturation of joints. In this study, the influence of imbalanced muscular loading on joint development was studied using localized chemical denervation of hip stabilizing muscle groups in neonatal mice. It was hypothesized that imbalanced muscle loading, targeting either gluteal muscles or quadriceps muscles, would lead to bilateral hip joint asymmetry, as measured by acetabular coverage, femoral head volume and bone morphometry, and femoral-acetabular shape. The contralateral hip joints as well as age-matched, uninjected mice were used as controls. Altered bone development was analyzed using micro-computed tomography, histology, and image registration techniques at postnatal days (P) 28, 56, and 120. This study found that unilateral muscle unloading led to reduced acetabular coverage of the femoral head, lower total volume, lower bone volume ratio, and lower mineral density, at all three time points. Histologically, the femoral head was smaller in unloaded hips, with thinner triradiate cartilage at P28 and thinner cortical bone at P120 compared to contralateral hips. Morphological shape changes were evident in unloaded hips at P56. Unloaded hips had lower trabecular thickness and increased trabecular spacing of the femoral head compared to contralateral hips. The present study suggests that decreased muscle loading of the hip leads to altered bone and joint shape and growth during postnatal maturation. Statement of Clinical Significance: Adaptations from altered muscle loading during postnatal growth investigated in this study have implications on developmental hip disorders that result from asymmetric loading, such as patients with limb-length inequality or dysplasia. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1128-1136, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Stabilization of gaze during circular locomotion in darkness. II. Contribution of velocity storage to compensatory eye and head nystagmus in the running monkey

    NASA Technical Reports Server (NTRS)

    Solomon, D.; Cohen, B.

    1992-01-01

    1. Yaw eye in head (Eh) and head on body velocities (Hb) were measured in two monkeys that ran around the perimeter of a circular platform in darkness. The platform was stationary or could be counterrotated to reduce body velocity in space (Bs) while increasing gait velocity on the platform (Bp). The animals were also rotated while seated in a primate chair at eccentric locations to provide linear and angular accelerations similar to those experienced while running. 2. Both animals had head and eye nystagmus while running in darkness during which slow phase gaze velocity on the body (Gb) partially compensated for body velocity in space (Bs). The eyes, driven by the vestibuloocular reflex (VOR), supplied high-frequency characteristics, bringing Gb up to compensatory levels at the beginning and end of the slow phases. The head provided substantial gaze compensation during the slow phases, probably through the vestibulocollic reflex (VCR). Synchronous eye and head quick phases moved gaze in the direction of running. Head movements occurred consistently only when animals were running. This indicates that active body and limb motion may be essential for inducing the head-eye gaze synergy. 3. Gaze compensation was good when running in both directions in one animal and in one direction in the other animal. The animals had long VOR time constants in these directions. The VOR time constant was short to one side in one animal, and it had poor gaze compensation in this direction. Postlocomotory nystagmus was weaker after running in directions with a long VOR time constant than when the animals were passively rotated in darkness. We infer that velocity storage in the vestibular system had been activated to produce continuous Eh and Hb during running and to counteract postrotatory afterresponses. 4. Continuous compensatory gaze nystagmus was not produced by passive eccentric rotation with the head stabilized or free. This indicates that an aspect of active locomotion, most likely somatosensory feedback, was responsible for activating velocity storage. 5. Nystagmus was compared when an animal ran in darkness and in light. the beat frequency of eye and head nystagmus was lower, and the quick phases were larger in darkness. The duration of head and eye quick phases covaried. Eye quick phases were larger when animals ran in darkness than when they were passively rotated. The maximum velocity and duration of eye quick phases were the same in both conditions. 6. The platform was counterrotated under one monkey in darkness while it ran in the direction of its long vestibular time constant.(ABSTRACT TRUNCATED AT 400 WORDS).

  14. Using Tri-Axial Accelerometers to Assess the Dynamic Control of Head Posture During Gait

    NASA Technical Reports Server (NTRS)

    Lawrence, John H., III

    2003-01-01

    Long duration spaceflight is known to cause a variety of biomedical stressors to the astronaut. One of the more functionally destabilizing effects of spaceflight involves microgravity-induced changes in vestibular or balance control. Balance control requires the integration of the vestibular, visual, and proprioceptive systems. In the microgravity environment, the normal gravity vector present on Earth no longer serves as a reference for the balance control system. Therefore, adaptive changes occur to the vestibular system to affect control of body orientation with altered, or non-present, gravity and/or proprioceptive inputs. Upon return to a gravity environment, the vestibular system must re-incorporate the gravity vector and gravity-induced proprioceptive inputs into the balance control regime. The result is often a period of postural instability, which may also be associated with space motion sickness (oscillopsia, nausea, and vertigo). Previous studies by the JSC Neuroscience group have found that returning astronauts often employ alterations in gait mechanics to maintain postural control during gait. It is believed that these gait alterations are meant to decrease the transfer of heel strike shock energy to the head, thus limiting the contradictory head and eye movements that lead to gait instability and motion sickness symptoms. We analyzed pre- and post-spaceflight tri-axial accelerometer data from the NASA/MIR long duration spaceflight missions to assess the heel to head transfer of heel strike shock energy during locomotion. Up to seven gait sessions (three preflight, four postflight) of head and shank (lower leg) accelerometer data was previously collected from six astronauts who engaged in space flights of four to six months duration. In our analysis, the heel to head transmission of shock energy was compared using peak vertical acceleration (a), peak jerk (j) ratio, and relative kinetic energy (a). A host of generalized movement variables was produced in an effort to isolate those that best highlighted vestibular adaptation due to spaceflight. Data suggest that astronauts used either head or body centered control to reduce the effects of heel strike shock on head position during normal walking at self-selected speeds. Moreover, the form of that control appears to fall under one of two categories: homeostatic or adaptive. Homeostatic control refers to tight constraint (small error) over the value of a given variable before and after spaceflight with little or no adaptive changes. Adaptive control refers to lesser constraint over a given movement variable with clear adaptation to earth gravity upon return from spaceflight. Heel strike shock absorption (ratio of heel to head peak acceleration) best-discriminated head and body centered control strategies. Further, peak jerk data was useful for illustrating pre- and postflight differences in segmental (shank versus head) movement energy. Results from kinetic energy analysis show high consistency between subjects and across test dates. Whether this result highlights a control strategy or is an artifact of approximating body segments using anthropometric tables is, at this point, unclear.

  15. Cannabis use and cancer of the head and neck: case-control study.

    PubMed

    Aldington, Sarah; Harwood, Matire; Cox, Brian; Weatherall, Mark; Beckert, Lutz; Hansell, Anna; Pritchard, Alison; Robinson, Geoffrey; Beasley, Richard

    2008-03-01

    To investigate whether cannabis smoking increases the risk of head and neck cancer. Case-control study. Cases of head and neck cancer < or =55 years identified from hospital databases and the Cancer Registry, and controls randomly selected from the electoral roll completed interviewer-administered questionnaires. Logistic regression was used to estimate the relative risk of head and neck cancer. There were 75 cases and 319 controls. An increased risk of cancer was found with increasing tobacco use, alcohol consumption, and decreased income but not increasing cannabis use. The highest tertile of cannabis use (>8.3 joint years) was associated with a nonsignificant increased risk of cancer (relative risk = 1.6, 95% confidence interval, 0.5-5.2) after adjustment for confounding variables. Cannabis use did not increase the risk of head and neck cancer; however, because of the limited power and duration of use studied, a small or longer-term effect cannot be excluded.

  16. Analysis of the intraseasonal stability of field test performances in young academy soccer players.

    PubMed

    Francioni, Fabio Massimo; Figueiredo, António José; Terribili, Marco; Tessitore, Antonio

    2016-01-01

    This study aimed to observe the intraseasonal stability of anthropometric, technical and functional test results in academy soccer players of different age categories. In total, 103 participants (age range: 7.7-13.4 years) by 5 age categories of the same academy were recruited for this study. Players were submitted to a field-test battery comprising 3 anthropometric measurements (body mass, stature and body mass index), 6 soccer technical tests (to assess the ability of ball control, ball control with the head, pass accuracy, shooting accuracy, dribbling and dribbling with pass) and 3 functional tests (countermovement jump with the hands on the hip, countermovement jump with free hands and 15-m linear sprint) that was administered in 4 test sessions during the same season. Though anthropometric results showed a clear increment in each age category across the season, the fluctuation of technical test results depended on age category and test session. Moreover, a significant increase in the results of functional tests was observed in most of the age categories, in particular, for the assessment of lower power limb. In conclusion, collecting repeated intraseason measurements permits the identification of players' fluctuations of performance across the season and allows coaches to make frequent adjustments of their programmes.

  17. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    PubMed

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  18. Blood pool scintigraphy of the skull in relation to head-down tilt provocation in patients with chronic tension-type headache and controls.

    PubMed

    Hannerz, Jan; Schnell, P-O; Larsson, Stig; Jacobsson, Hans

    2004-03-01

    To investigate the mechanisms behind the increase of chronic tension-type headache during head-down tilt. The pathophysiology of chronic tension-type headache is unknown. Ten patients suffering from chronic tension-type headache and 10 age- and sex-matched controls were studied with respect to pain intensity and alterations in cranial blood volume using planar scintigraphy and radiolabeled autologous erythrocytes before, during, and after head-down tilt, a procedure known to increase chronic tension-type headache. Four of 8 patients with chronic tension-type headache studied had increased cerebrospinal fluid pressure. During head-down tilt, the pain increased significantly in the group with chronic tension-type headache (P <.001) while the procedure did not cause headache in the controls. Blood volume significantly increased extracranially and decreased intracranially in both groups during head-down tilt. The extracranial nasal blood volume was significantly related to the pain experienced by the patients with chronic tension-type headache before and during head-down tilt. Although the changes in blood volume and, presumably, the increase of intracranial pressure were similar in the patients with chronic tension-type headache and the controls, only the patients experienced pain and pain increase during head-down tilt. This indicates that the pre-head-down tilt conditions must be different in the 2 groups and should be related to increased cerebrospinal fluid pressure/intracranial venous pressure in patients with chronic tension-type headache compared with controls. A difference in central mechanisms may, however, also be of importance for the difference in headache provocation in the 2 groups during head-down tilt.

  19. Effects of electrolytes and surfactants on the morphology and stability of advanced silver nano-materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Obaid, Abdullah Yousif; AL-Thabaiti, Shaeel Ahmed; El-Mossalamy, E.H.

    2013-03-15

    Highlights: ► Stoichiometric ratio of S{sub 2}O{sub 3}{sup 2−} and Ag{sup +} ions are responsible to the formation of prefect transparent yellow colored silver sol. ► Higher S{sub 2}O{sub 3}{sup 2−} concentrations has damping effect. ► Head group of the surfactants and nature of the electrolytes have significant effect on the stability of silver nanoparticles. - Abstract: The impact of electrolytes, stabilizing and/or capping agents on morphology of colloidal silver nano-materials (AgNPs) has been studied spectroscopically. Sodium thiosulfate acts as reducing-, stabilizing- and damping-agents. Stoichiometric ratios of S{sub 2}O{sub 3}{sup 2−} and Ag{sup +} ions were responsible to the formationmore » stable and prefect transparent dark yellow colored AgNPs. The S{sub 2}O{sub 3}{sup 2−}-stabilized AgNPs were significantly more stable in inorganic electrolytes (NaNO{sub 3}, Na{sub 2}SO{sub 4}, Na{sub 2}CO{sub 3} and KBr). S{sub 2}O{sub 3}{sup 2−} is adsorbed more strongly than the used other anions. The addition of cetyltrimethylammonium bromide (CTAB) and sodium dodecylsulfate (SDS) has significant effects on the absorbance of S{sub 2}O{sub 3}{sup 2−}-stabilized AgNPs which can be rationalized in terms of electrostatic attraction and repulsion between the adsorbed S{sub 2}O{sub 3}{sup 2−} ions on to the surface of AgNPs and cationic and/or anionic head groups of used surfactants, respectively. Transmission electron microscopy images suggest that AgNPs are polydispersed, spherical and exhibiting an interesting irregular morphology.« less

  20. Fixation of fractures of the condylar head of the mandible with a new magnesium-alloy biodegradable cannulated headless bone screw.

    PubMed

    Leonhardt, H; Franke, A; McLeod, N M H; Lauer, G; Nowak, A

    2017-07-01

    It is difficult to fix fractures of the condylar head of the mandible. Several techniques have been described which show satisfactory outcomes, but stability can be questionable, and some can cause irritation of the soft tissues. We describe a technique and first results of treating such fractures with resorbable magnesium-based headless bone screws (Magnezix ® 2.7mm CS; Syntellix AG, Hanover, Germany). Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures.

    PubMed

    Jenkins, Paul J; Ramaesh, Rishikesan; Pankaj, Pankaj; Patton, James T; Howie, Colin R; Goffin, Jérôme M; Merwe, Andrew van der; Wallace, Robert J; Porter, Daniel E; Simpson, A Hamish

    2013-10-01

    The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. 6 femoral heads, obtained during arthroplasty surgery for femoral neck fracture, underwent micro-computed tomography (microCT) scanning at 30 μm, and bone volume ratio (BV/TV), trabecular thickness, structural model index, connection density, and degree of anisotropy for volumes of interest throughout the head were derived. A further 15 femoral heads underwent mechanical testing of compressive failure stress of cubes of trabecular bone from different regions of the head. The greatest density and trabecular thickness was found in the central core that extended from the medial calcar to the physeal scar. This region also correlated with the greatest degree of anisotropy and proportion of plate-like trabeculae. In the epiphyseal region, the trabeculae were organized radially from the physeal scar. The weakest area was found at the apex and peripheral areas of the head. The strongest region was at the center of the head. The center of the femoral head contained the strongest trabecular bone, with the thickest, most dense trabeculae. The apical region was weaker. From an anatomical and mechanical point of view, implants that achieve fixation in or below this central core may achieve the most stable fixation during fracture healing.

  2. Inverse Modelling to Obtain Head Movement Controller Signal

    NASA Technical Reports Server (NTRS)

    Kim, W. S.; Lee, S. H.; Hannaford, B.; Stark, L.

    1984-01-01

    Experimentally obtained dynamics of time-optimal, horizontal head rotations have previously been simulated by a sixth order, nonlinear model driven by rectangular control signals. Electromyography (EMG) recordings have spects which differ in detail from the theoretical rectangular pulsed control signal. Control signals for time-optimal as well as sub-optimal horizontal head rotations were obtained by means of an inverse modelling procedures. With experimentally measured dynamical data serving as the input, this procedure inverts the model to produce the neurological control signals driving muscles and plant. The relationships between these controller signals, and EMG records should contribute to the understanding of the neurological control of movements.

  3. An auto-locked diode laser system for precision metrology

    NASA Astrophysics Data System (ADS)

    Beica, H. C.; Carew, A.; Vorozcovs, A.; Dowling, P.; Pouliot, A.; Barron, B.; Kumarakrishnan, A.

    2017-05-01

    We present a unique external cavity diode laser system that can be auto-locked with reference to atomic and molecular spectra. The vacuum-sealed laser head design uses an interchangeable base-plate comprised of a laser diode and optical elements that can be selected for desired wavelength ranges. The feedback light to the laser diode is provided by a narrow-band interference filter, which can be tuned from outside the laser cavity to fineadjust the output wavelength in vacuum. To stabilize the laser frequency, the digital laser controller relies either on a pattern-matching algorithm stored in memory, or on first or third derivative feedback. We have used the laser systems to perform spectroscopic studies in rubidium at 780 nm, and in iodine at 633 nm. The linewidth of the 780-nm laser system was measured to be ˜500 kHz, and we present Allan deviation measurements of the beat note and the lock stability. Furthermore, we show that the laser system can be the basis for a new class of lidar transmitters in which a temperature-stabilized fiber-Bragg grating is used to generate frequency references for on-line points of the transmitter. We show that the fiber-Bragg grating spectra can be calibrated with reference to atomic transitions.

  4. Dynamic interactions of eye and head movements when reading with single-vision and progressive lenses in a simulated computer-based environment.

    PubMed

    Han, Ying; Ciuffreda, Kenneth J; Selenow, Arkady; Ali, Steven R

    2003-04-01

    To assess dynamic interactions of eye and head movements during return-sweep saccades (RSS) when reading with single-vision (SVL) versus progressive-addition (PAL) lenses in a simulated computer-based business environment. Horizontal eye and head movements were recorded objectively and simultaneously at a rate of 60 Hz during reading of single-page (SP; 14 degrees horizontal [H]) and double-page (DP; 37 degrees H) formats at 60 cm with binocular viewing. Subjects included 11 individuals with normal presbyopic vision aged 45 to 71 years selected by convenience sampling from a clinic population. Reading was performed with three types of spectacle lenses with a different clear near field of view (FOV): a SVL (60 degrees H clear FOV), a PAL-I with a relatively wide intermediate zone (7.85 mm; 18 degrees H clear FOV), and a PAL-II with a relatively narrow intermediate zone (5.60 mm; 13 degrees H clear FOV). Eye movements were initiated before head movements in the SP condition, and the reverse was found in the DP condition, with all three lens types. Duration of eye movements increased as the zone of clear vision decreased in the SP condition, and they were longer with the PALs than with the SVL in the DP condition. Gaze stabilization occurred later with the PALs than with the SVL in both the SP and DP conditions. The duration of head movements was longer with the PAL-II than with the SVL in both the SP and DP conditions. Eye movement peak velocity was greater with the SVL than the PALs in the DP condition. Eye movement and head movement strategies and timing were contingent on viewing conditions. The longer eye movement duration and gaze-stabilization times suggested that additional eye movements were needed to locate the clear-vision zone and commence reading after the RSS. Head movements with PALs for the SP condition were similarly optically induced. These eye movement and head movement results may contribute to the reduced reading rate and related symptoms reported by some PAL wearers. The dynamic interactions of eye movements and head movements during reading with the PALs appear to be a sensitive indicator of the effect of lens optical design parameters on overall reading performance, because the movements can discriminate between SVL and PAL designs and at times even between PALs.

  5. Intercepting a sound without vision

    PubMed Central

    Vercillo, Tiziana; Tonelli, Alessia; Gori, Monica

    2017-01-01

    Visual information is extremely important to generate internal spatial representations. In the auditory modality, the absence of visual cues during early infancy does not preclude the development of some spatial strategies. However, specific spatial abilities might result impaired. In the current study, we investigated the effect of early visual deprivation on the ability to localize static and moving auditory stimuli by comparing sighted and early blind individuals’ performance in different spatial tasks. We also examined perceptual stability in the two groups of participants by matching localization accuracy in a static and a dynamic head condition that involved rotational head movements. Sighted participants accurately localized static and moving sounds. Their localization ability remained unchanged after rotational movements of the head. Conversely, blind participants showed a leftward bias during the localization of static sounds and a little bias for moving sounds. Moreover, head movements induced a significant bias in the direction of head motion during the localization of moving sounds. These results suggest that internal spatial representations might be body-centered in blind individuals and that in sighted people the availability of visual cues during early infancy may affect sensory-motor interactions. PMID:28481939

  6. Contribution of the cerebellar flocculus to gaze control during active head movements

    NASA Technical Reports Server (NTRS)

    Belton, T.; McCrea, R. A.; Peterson, B. W. (Principal Investigator)

    1999-01-01

    The flocculus and ventral paraflocculus are adjacent regions of the cerebellar cortex that are essential for controlling smooth pursuit eye movements and for altering the performance of the vestibulo-ocular reflex (VOR). The question addressed in this study is whether these regions of the cerebellum are more globally involved in controlling gaze, regardless of whether eye or active head movements are used to pursue moving visual targets. Single-unit recordings were obtained from Purkinje (Pk) cells in the floccular region of squirrel monkeys that were trained to fixate and pursue small visual targets. Cell firing rate was recorded during smooth pursuit eye movements, cancellation of the VOR, combined eye-head pursuit, and spontaneous gaze shifts in the absence of targets. Pk cells were found to be much less sensitive to gaze velocity during combined eye-head pursuit than during ocular pursuit. They were not sensitive to gaze or head velocity during gaze saccades. Temporary inactivation of the floccular region by muscimol injection compromised ocular pursuit but had little effect on the ability of monkeys to pursue visual targets with head movements or to cancel the VOR during active head movements. Thus the signals produced by Pk cells in the floccular region are necessary for controlling smooth pursuit eye movements but not for coordinating gaze during active head movements. The results imply that individual functional modules in the cerebellar cortex are less involved in the global organization and coordination of movements than with parametric control of movements produced by a specific part of the body.

  7. Patients with migraine correctly estimate the visual verticality.

    PubMed

    Crevits, Luc; Vanacker, Leen; Verraes, Anouk

    2012-05-01

    We wanted to study otolith function by measuring the static subjective visual vertical (SVV) in migraine patients and in controls with and without kinetosis (motion sickness). Forty-seven patients with moderately severe migraine and 96 healthy controls were enrolled. Using a questionnaire, persons with kinetosis were identified. The SVV test was performed in a totally dark room. Subjects wore a stiffneck to stabilize the head in an erect position. They were required to adjust an infrared line to the gravitational vertical with a hand-held infrared remote controlled potentiometer. The deviation of SVV in the group of migraine patients was not significantly different from that of controls, regardless of whether an aura was associated. SVV was not significantly influenced by the presence of dizziness/non specific vertigo or kinetosis. Patients with moderately severe migraine under prophylactic medication correctly estimate the visual verticality in the headache-free period. It is suggested that a deviation of SVV in a headache-free migraine patient may not be attributed to his migraine disorder as such regardless whether kinetosis is associated. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Recovery trajectories of vestibulopathic subjects after perturbations during locomotion

    NASA Technical Reports Server (NTRS)

    Wall, C. 3rd; Oddsson, L. I.; Patronik, N.; Sienko, K.; Kentala, E.

    2002-01-01

    We compared the mediolateral (M/L) responses to perturbations during locomotion of vestibulopathic (VP) subjects to those of controls. Eight subjects with unilateral vestibular loss (100% Reduced Vestibular Response from the caloric test) resulting from surgery for vestibular schwannoma and 11 controls were selected for this study. Despite their known vestibulopathy, all VP subjects scored within the normal range on computerized dynamic posturography Sensory Organization Tests. During gait, subjects were given surface perturbations of the right support-phase foot in two possible directions (forward-right and backward-left) at two possible magnitudes (5 and 10 cm) that were randomly mixed with trials having no perturbations. M/L stability was quantified by estimating the length of the M/L moment arm between the support foot and the trunk, and the M/L accelerations of the sternum and the head. The VP group had greater changes (p < 0.05) in their moment arm responses compared to controls. The number of steps that it took for the moment arm oscillations to return to normal and the variability in the moment arms were greater for the VP group. Differences in the sternum and head accelerations between VP and control groups were not as consistent, but there was a trend toward greater response deviations in the VP group for all 4 perturbation types. Increased response magnitude and variability of the VP group is consistent with an increase in their sensory noise of vestibular inputs due to the surgical lesion. Another possibility is a reduced sensitivity to motion inputs. This perturbation approach may prove useful for characterizing subtle vestibulopathies and similar changes in the human orientation mechanism after exposure to microgravity.

  9. Flight evaluation of advanced controls and displays for transition and landing on the NASA V/STOL systems research aircraft

    NASA Technical Reports Server (NTRS)

    Franklin, James A.; Stortz, Michael W.; Borchers, Paul F.; Moralez, Ernesto, III

    1996-01-01

    Flight experiments were conducted on Ames Research Center's V/STOL Systems Research Aircraft (VSRA) to assess the influence of advanced control modes and head-up displays (HUD's) on flying qualities for precision approach and landing operations. Evaluations were made for decelerating approaches to hover followed by a vertical landing and for slow landings for four control/display mode combinations: the basic YAV-8B stability augmentation system; attitude command for pitch, roll, and yaw; flightpath/acceleration command with translational rate command in the hover; and height-rate damping with translational-rate command. Head-up displays used in conjunction with these control modes provided flightpath tracking/pursuit guidance and deceleration commands for the decelerating approach and a mixed horizontal and vertical presentation for precision hover and landing. Flying qualities were established and control usage and bandwidth were documented for candidate control modes and displays for the approach and vertical landing. Minimally satisfactory bandwidths were determined for the translational-rate command system. Test pilot and engineer teams from the Naval Air Warfare Center, the Boeing Military Airplane Group, Lockheed Martin, McDonnell Douglas Aerospace, Northrop Grumman, Rolls-Royce, and the British Defense Research Agency participated in the program along with NASA research pilots from the Ames and Lewis Research Centers. The results, in conjunction with related ground-based simulation data, indicate that the flightpath/longitudinal acceleration command response type in conjunction with pursuit tracking and deceleration guidance on the HUD would be essential for operation to instrument minimums significantly lower than the minimums for the AV-8B. It would also be a superior mode for performing slow landings where precise control to an austere landing area such as a narrow road is demanded. The translational-rate command system would reduce pilot workload for demanding vertical landing tasks aboard ship and in confined land-based sites.

  10. Bleeding Efficiency, Microbiological Quality and Oxidative Stability of Meat from Goats Subjected to Slaughter without Stunning in Comparison with Different Methods of Pre-Slaughter Electrical Stunning

    PubMed Central

    Sabow, Azad Behnan; Zulkifli, Idrus; Goh, Yong Meng; Ab Kadir, Mohd Zainal Abidin; Kaka, Ubedullah; Imlan, Jurhamid Columbres; Abubakar, Ahmed Abubakar; Adeyemi, Kazeem Dauda; Sazili, Awis Qurni

    2016-01-01

    The influence of pre-slaughter electrical stunning techniques and slaughter without stunning on bleeding efficiency and shelf life of chevon during a 14 d postmortem aging were assessed. Thirty two Boer crossbred bucks were randomly assigned to four slaughtering techniques viz slaughter without stunning (SWS), low frequency head-only electrical stunning (LFHO; 1 A for 3 s at a frequency of 50 Hz), low frequency head-to-back electrical stunning (LFHB; 1 A for 3 s at a frequency of 50 Hz) and high frequency head-to-back electrical stunning (HFHB; 1 A for 3 s at a frequency of 850 Hz). The SWS, LFHO and HFHB goats had higher (p<0.05) blood loss and lower residual hemoglobin in muscle compared to LFHB. The LFHB meat had higher (p<0.05) TBARS value than other treatments on d 7 and 14 d postmortem. Slaughtering methods had no effect on protein oxidation. Higher bacterial counts were observed in LFHB meat compared to those from SWS, LFHO and HFHB after 3 d postmortem. Results indicate that the low bleed-out in LFHB lowered the lipid oxidative stability and microbiological quality of chevon during aging. PMID:27035716

  11. Bleeding Efficiency, Microbiological Quality and Oxidative Stability of Meat from Goats Subjected to Slaughter without Stunning in Comparison with Different Methods of Pre-Slaughter Electrical Stunning.

    PubMed

    Sabow, Azad Behnan; Zulkifli, Idrus; Goh, Yong Meng; Ab Kadir, Mohd Zainal Abidin; Kaka, Ubedullah; Imlan, Jurhamid Columbres; Abubakar, Ahmed Abubakar; Adeyemi, Kazeem Dauda; Sazili, Awis Qurni

    2016-01-01

    The influence of pre-slaughter electrical stunning techniques and slaughter without stunning on bleeding efficiency and shelf life of chevon during a 14 d postmortem aging were assessed. Thirty two Boer crossbred bucks were randomly assigned to four slaughtering techniques viz slaughter without stunning (SWS), low frequency head-only electrical stunning (LFHO; 1 A for 3 s at a frequency of 50 Hz), low frequency head-to-back electrical stunning (LFHB; 1 A for 3 s at a frequency of 50 Hz) and high frequency head-to-back electrical stunning (HFHB; 1 A for 3 s at a frequency of 850 Hz). The SWS, LFHO and HFHB goats had higher (p<0.05) blood loss and lower residual hemoglobin in muscle compared to LFHB. The LFHB meat had higher (p<0.05) TBARS value than other treatments on d 7 and 14 d postmortem. Slaughtering methods had no effect on protein oxidation. Higher bacterial counts were observed in LFHB meat compared to those from SWS, LFHO and HFHB after 3 d postmortem. Results indicate that the low bleed-out in LFHB lowered the lipid oxidative stability and microbiological quality of chevon during aging.

  12. Head Direction Cell Instability in the Anterior Dorsal Thalamus after Lesions of the Interpeduncular Nucleus

    PubMed Central

    Clark, Benjamin J.; Sarma, Asha; Taube, Jeffrey S.

    2009-01-01

    Previous research has identified a population of cells throughout the limbic system that discharge as a function of the animals head direction (HD). Altering normal motor cues can alter the HD cell responses and disrupt the updating of their preferred firing directions, thus suggesting that motor cues contribute to processing the HD signal. A pathway that conveys motor information may stem from the interpeduncular nucleus (IPN), a brain region that has reciprocal connections with HD cell circuitry. To test this hypothesis, we produced electrolytic or neurotoxic lesions of the IPN and recorded HD cells in the anterior dorsal thalamus (ADN) of rats. Direction-specific firing remained present in the ADN after lesions of the IPN, but measures of HD cell properties showed that cells had reduced peak firing rates, large directional firing ranges, and firing that predicted the animal’s future heading more than in intact controls. Furthermore, preferred firing directions were moderately less influenced by rotation of a salient visual landmark. Finally, the preferred directions of cells in lesioned rats exhibited large shifts when the animals foraged for scattered food-pellets in a darkened environment and when locomoting from a familiar environment to a novel one. We propose that the IPN contributes motor information about the animal’s movements to the HD cell circuitry. Further, these results suggest that the IPN plays a broad role in the discharge properties and stability of direction-specific activity in the HD cell circuit. PMID:19144850

  13. Sternal closure reinforced with rib heads: a novel technique for prevention and treatment of sternal dehiscence.

    PubMed

    Vural, A Hakan; Yalçinkaya, Serhat; Türk, Tamer; Oztürk, Alpaslan; Sezen, Mustafa; Yavuz, Senol; Ozyazicioglu, Ahmet

    2007-01-01

    When a sternotomy cannot be performed at the midline and/or there is infection at the operation site, sternotomy revision can cause problems that increase the mortality and morbidity of the patients. There is no agreement on the best treatment method. In this paper we present a modified wiring technique. This technique consisted of wrapping wires twice around each rib head and placing standard circumferential wire sutures, thus providing full stability by decreasing the load on the sternum using only steel wires. The study group included 23 patients with sternal dehiscence because of inappropriate sternotomy (n = 10) and/or mediastinitis (n = 13). Two mediastinal tubes were placed for irrigation in 13 patients with mediastinitis and/or wound infection, and mobilization and interposition of omentum as an axial graft was performed in 2 patients. Irrigation and antibiotherapy were continued for 4 to 6 weeks. Complete wound healing was obtained in all patients. Twenty-two patients treated with this technique survived. One patient died on postoperative 42nd day because of renal insufficiency and multi-organ failure. Early and aggressive debridement of infected and necrotic tissue, irrigation, and antibiotics are necessary for successful treatment, but we believe that the most important factor is full stabilization of the sternal tissue with minimal use of foreign stabilization material. Despite the limited number of cases, we suggest that our stabilization technique seems to be successful in achieving full stabilization even in infected and fragile sternal bony tissue in patients with sternal dehiscence and/or inappropriate sternotomy.

  14. Visuomotor Transformation in the Fly Gaze Stabilization System

    PubMed Central

    Huston, Stephen J; Krapp, Holger G

    2008-01-01

    For sensory signals to control an animal's behavior, they must first be transformed into a format appropriate for use by its motor systems. This fundamental problem is faced by all animals, including humans. Beyond simple reflexes, little is known about how such sensorimotor transformations take place. Here we describe how the outputs of a well-characterized population of fly visual interneurons, lobula plate tangential cells (LPTCs), are used by the animal's gaze-stabilizing neck motor system. The LPTCs respond to visual input arising from both self-rotations and translations of the fly. The neck motor system however is involved in gaze stabilization and thus mainly controls compensatory head rotations. We investigated how the neck motor system is able to selectively extract rotation information from the mixed responses of the LPTCs. We recorded extracellularly from fly neck motor neurons (NMNs) and mapped the directional preferences across their extended visual receptive fields. Our results suggest that—like the tangential cells—NMNs are tuned to panoramic retinal image shifts, or optic flow fields, which occur when the fly rotates about particular body axes. In many cases, tangential cells and motor neurons appear to be tuned to similar axes of rotation, resulting in a correlation between the coordinate systems the two neural populations employ. However, in contrast to the primarily monocular receptive fields of the tangential cells, most NMNs are sensitive to visual motion presented to either eye. This results in the NMNs being more selective for rotation than the LPTCs. Thus, the neck motor system increases its rotation selectivity by a comparatively simple mechanism: the integration of binocular visual motion information. PMID:18651791

  15. 77 FR 51615 - DMH Trust fbo Martha M. Head-Acquisition of Control Exemption-Twin Cities & Western Railroad...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-24

    ... Martha M. Head--Acquisition of Control Exemption-- Twin Cities & Western Railroad Company, Minnesota Prairie Line, Inc. and Sisseton Milbank Railroad Company DMH Trust fbo Martha M. Head (the Trust), a... Class III rail carriers. \\1\\ MPL and SMRC are wholly owned subsidiaries of TCW. According to the Trust...

  16. Locomotor Dysfunction after Long-Duration Space Flight and Development of Countermeasures to Facilitate Faster Recovery

    NASA Technical Reports Server (NTRS)

    Mulavara, A. P.; Wood, S. J.; Cohen, H. S.; Bloomberg, J. J.

    2012-01-01

    Exposure to the microgravity conditions of space flight induces adaptive modification in sensorimotor function allowing astronauts to operate in this unique environment. This adaptive state, however, is inappropriate for a 1-g environment. Consequently astronauts must spend time readapting to Earth s gravity following their return to Earth. During this readaptation period, alterations in sensorimotor function cause various disturbances in astronaut gait during postflight walking. They often rely more on vision for postural and gait stability and many report the need for greater cognitive supervision of motor actions that previous to space flight were fully automated. Over the last several years our laboratory has investigated postflight astronaut locomotion with the aim of better understanding how adaptive changes in underlying sensorimotor mechanisms contribute to postflight gait dysfunction. Exposure to the microgravity conditions of space flight induces adaptive modification in the control of vestibularly-mediated reflexive head movement during locomotion after space flight. Furthermore, during motor learning, adaptive transitions are composed of two main mechanisms: strategic and plastic. Strategic mechanisms represent immediate and transitory modifications in control to deal with changes in the prevailing environment that, if prolonged, induce plastic mechanisms designed to automate new behavioral responses. The goal of the present study was to examine the contributions of sensorimotor subsystems such as the vestibular and body load sensing (BLS) somatosensory influences on head movement control during locomotion after long-duration space flight. Further we present data on the two motor learning processes during readaptation of locomotor function after long-duration space flight.

  17. Current status of EVA degradation in Si modules and interface stability in CdTe/CdS modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Czanderna, A.W.

    1994-06-30

    The goals, objectives, background, technical approach, status, and accomplishments on the PV Module Reliability Research Task are summarized for FY 1993. The accomplishments are reported in two elements, ethylene vinyl acetate (EVA) degradation and stability in CdTe/CdS modules. The EVA results are presented under the headings modified EVA and potential EVA replacements, degradation mechanisms, efficiency losses from yellowed EVA, and equipment acquisitions. The results on CdTe/CdS modules are presented under subheadings of stability of the SnO[sub 2]/CdS interface and degradation at the CdTe/CdS interface.

  18. A multi‐centre evaluation of nine rapid, point‐of‐care syphilis tests using archived sera

    PubMed Central

    Herring, A J; Ballard, R C; Pope, V; Adegbola, R A; Changalucha, J; Fitzgerald, D W; Hook, E W; Kubanova, A; Mananwatte, S; Pape, J W; Sturm, A W; West, B; Yin, Y P; Peeling, R W

    2006-01-01

    Objectives To evaluate nine rapid syphilis tests at eight geographically diverse laboratory sites for their performance and operational characteristics. Methods Tests were compared “head to head” using locally assembled panels of 100 archived (50 positive and 50 negative) sera at each site using as reference standards the Treponema pallidum haemagglutination or the T pallidum particle agglutination test. In addition inter‐site variation, result stability, test reproducibility and test operational characteristics were assessed. Results All nine tests gave good performance relative to the reference standard with sensitivities ranging from 84.5–97.7% and specificities from 84.5–98%. Result stability was variable if result reading was delayed past the recommended period. All the tests were found to be easy to use, especially the lateral flow tests. Conclusions All the tests evaluated have acceptable performance characteristics and could make an impact on the control of syphilis. Tests that can use whole blood and do not require refrigeration were selected for further evaluation in field settings. PMID:17118953

  19. Head motion parameters in fMRI differ between patients with mild cognitive impairment and Alzheimer disease versus elderly control subjects.

    PubMed

    Haller, Sven; Monsch, Andreas U; Richiardi, Jonas; Barkhof, Frederik; Kressig, Reto W; Radue, Ernst W

    2014-11-01

    Motion artifacts are a well-known and frequent limitation during neuroimaging workup of cognitive decline. While head motion typically deteriorates image quality, we test the hypothesis that head motion differs systematically between healthy controls (HC), amnestic mild cognitive impairment (aMCI) and Alzheimer disease (AD) and consequently might contain diagnostic information. This prospective study was approved by the local ethics committee and includes 28 HC (age 71.0 ± 6.9 years, 18 females), 15 aMCI (age 67.7 ± 10.9 years, 9 females) and 20 AD (age 73.4 ± 6.8 years, 10 females). Functional magnetic resonance imaging (fMRI) at 3T included a 9 min echo-planar imaging sequence with 180 repetitions. Cumulative average head rotation and translation was estimated based on standard fMRI preprocessing and compared between groups using receiver operating characteristic statistics. Global cumulative head rotation discriminated aMCI from controls [p < 0.01, area under curve (AUC) 0.74] and AD from controls (p < 0.01, AUC 0.73). The ratio of rotation z versus y discriminated AD from controls (p < 0.05, AUC 0.71) and AD from aMCI (p < 0.05, AUC of 0.75). Head motion systematically differs between aMCI/AD and controls. Since motion is not random but convoluted with diagnosis, the higher amount of motion in aMCI and AD as compared to controls might be a potential confounding factor for fMRI group comparisons. Additionally, head motion not only deteriorates image quality, yet also contains useful discriminatory information and is available for free as a "side product" of fMRI data preprocessing.

  20. In-flight evaluation of a fiber optic helmet-mounted display

    NASA Astrophysics Data System (ADS)

    Jennings, Sion A.; Gubbels, Arthur W.; Swail, Carl P.; Craig, Greg

    1998-08-01

    The National Research Council of Canada (NRC), in conjunction with the Canadian Department of National Defence (DND), is investigating the use of helmet-mounted displays (HMD) to improve pilot situational awareness in all-weather search and rescue helicopter operations. The National Research Council has installed a visually coupled HMD system in the NRC Bell 205 Airborne Simulator. Equipped with a full authority fly-by-wire control system, the Bell 205 has variable stability characteristics, which makes the airborne simulator the ideal platform for the integrated flight testing of HMDs in a simulated operational environment. This paper presents preliminary results from flight test of the NRC HMD. These results are in the form of numerical head tracker data, and subjective handling qualities ratings. Flight test results showed that the HMD degraded handling qualities due to reduced acuity, limited field-of-view, time delays in the sensor platform, and fatigue caused by excessive helmet inertia. Some evidence was found to support the hypothesis of an opto-kinetic cervical reflex whereby a pilot pitches and rolls his head in response to aircraft movements to maintain a level horizon in their field-of- view.

  1. Streamer development in barrier discharge in air: spectral signatures and electric field

    NASA Astrophysics Data System (ADS)

    Hoder, Tomas; Simek, Milan; Bonaventura, Zdenek; Prukner, Vaclav

    2015-09-01

    Electrical breakdown in the upper atmosphere takes form of so called Transient Luminous Events (TLE). Down to the certain pressure limit, the first phases of the TLE-phenomena are controlled by the streamer mechanism. In order to understand the development of these events, streamers in 10 torr air were generated in volume barrier discharge. Stability and reproducibility of generated streamers were secured by proper electrode geometry and specific applied voltage waveform. In this work, spectrally resolved measurements of the streamer head emission with high spatial and temporal resolution are presented. Precise recordings of the emission of the second positive and first negative systems of molecular nitrogen allowed the determination of the spatio-temporal development of the reduced electric field in the streamer head. This unique experimental result reveals in more details the early stages of the streamer development and gives, besides values for streamer velocity and its diameter, quantitative information on the magnitude of the electric field. T.H. was financed through the ESF Programme TEA-IS (Grant No. 4219), M.S. and V.P. by the AVCR under collaborative project M100431201 and Z.B. acknowledges the support of grant of Czech Science Foundation GA15-04023S.

  2. Accurate calibration and uncertainty estimation of the normal spring constant of various AFM cantilevers.

    PubMed

    Song, Yunpeng; Wu, Sen; Xu, Linyan; Fu, Xing

    2015-03-10

    Measurement of force on a micro- or nano-Newton scale is important when exploring the mechanical properties of materials in the biophysics and nanomechanical fields. The atomic force microscope (AFM) is widely used in microforce measurement. The cantilever probe works as an AFM force sensor, and the spring constant of the cantilever is of great significance to the accuracy of the measurement results. This paper presents a normal spring constant calibration method with the combined use of an electromagnetic balance and a homemade AFM head. When the cantilever presses the balance, its deflection is detected through an optical lever integrated in the AFM head. Meanwhile, the corresponding bending force is recorded by the balance. Then the spring constant can be simply calculated using Hooke's law. During the calibration, a feedback loop is applied to control the deflection of the cantilever. Errors that may affect the stability of the cantilever could be compensated rapidly. Five types of commercial cantilevers with different shapes, stiffness, and operating modes were chosen to evaluate the performance of our system. Based on the uncertainty analysis, the expanded relative standard uncertainties of the normal spring constant of most measured cantilevers are believed to be better than 2%.

  3. Stereometric Analysis Of Static Equilibrium In CNS Disorders

    NASA Astrophysics Data System (ADS)

    Sheffer, D. B.; Lehmkuhl, D. L.; Herron, R. E.

    1980-07-01

    A primary aim in the physical rehabilitation of individuals with severe head or spinal injuries resulting in hemiparesis, tetraparesis or paraparesis, is the restoration of the functional motor abilities controlling involved muscle groups. The regaining of trunk postural stability provides a valuable antecedent in the recovery of use of the arms and legs. Accurate objective infor-mation must be provided to the therapist for assessment of treatment regimes. At present, few objective practical methods are available to furnish this evaluative information. Therefore the purpose of this study was to investigate the use of a biostereometric range of motion sensor for recording and quantifying trunk static equilibrium in individuals ungergoing therapy for head trauma. The sensor located the relative position of the C-7 vertebrae of the patient in space using continual monitoring of spherical coordinates. Results of the test protocol included : plots of the movement of the trunk excursions, determination of the maximum area of excursion and a trunk sway index (the relationship of the maximum area, the total excursion distance and a time factor). Further results demonstrated that the biostereometric sensor yielded quantitative documentation of improvement in a patient undergoing therapy.

  4. Influence of Head Motion on the Accuracy of 3D Reconstruction with Cone-Beam CT: Landmark Identification Errors in Maxillofacial Surface Model.

    PubMed

    Lee, Kyung-Min; Song, Jin-Myoung; Cho, Jin-Hyoung; Hwang, Hyeon-Shik

    2016-01-01

    The purpose of this study was to investigate the influence of head motion on the accuracy of three-dimensional (3D) reconstruction with cone-beam computed tomography (CBCT) scan. Fifteen dry skulls were incorporated into a motion controller which simulated four types of head motion during CBCT scan: 2 horizontal rotations (to the right/to the left) and 2 vertical rotations (upward/downward). Each movement was triggered to occur at the start of the scan for 1 second by remote control. Four maxillofacial surface models with head motion and one control surface model without motion were obtained for each skull. Nine landmarks were identified on the five maxillofacial surface models for each skull, and landmark identification errors were compared between the control model and each of the models with head motion. Rendered surface models with head motion were similar to the control model in appearance; however, the landmark identification errors showed larger values in models with head motion than in the control. In particular, the Porion in the horizontal rotation models presented statistically significant differences (P < .05). Statistically significant difference in the errors between the right and left side landmark was present in the left side rotation which was opposite direction to the scanner rotation (P < .05). Patient movement during CBCT scan might cause landmark identification errors on the 3D surface model in relation to the direction of the scanner rotation. Clinicians should take this into consideration to prevent patient movement during CBCT scan, particularly horizontal movement.

  5. Standing balance tests for screening people with vestibular impairments.

    PubMed

    Cohen, Helen S; Mulavara, Ajitkumar P; Peters, Brian T; Sangi-Haghpeykar, Haleh; Bloomberg, Jacob J

    2014-02-01

    To improve the test standards for a version of the Romberg test and to determine whether measuring kinematic variables improved its utility for screening. Healthy controls and patients with benign paroxysmal positional vertigo, postoperative acoustic neuroma resection, and chronic peripheral unilateral weakness were compared. Subjects wore Bluetooth-enabled inertial motion units while standing on the floor or medium-density, compliant foam, with eyes open or closed, with head still or moving in pitch or yaw. Dependent measures were time to perform each test condition, number of head movements made, and kinematic variables. Patients and controls did not differ significantly with eyes open or with eyes closed while on the floor. With eyes closed, on foam, some significant differences were found between patients and controls, especially for subjects older than 59 years. Head movement conditions were more challenging than with the head still. Significantly fewer patients than controls could make enough head movements to obtain kinematic measures. Kinematics indicated that lateral balance control is significantly reduced in these patients compared to controls. Receiver operator characteristics and sensitivity/specificity analyses showed moderately good differences with older subjects. Tests on foam with eyes closed, with head still or moving, may be useful as part of a screening battery for vestibular impairments, especially for older people. 3b. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  6. SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogunmolu, O; Gans, N; Jiang, S

    Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance ofmore » the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.« less

  7. The dynamics of head-on collisions of spherical stellar systems

    NASA Astrophysics Data System (ADS)

    Narasimhan, K. S. V. S.; Alladin, Saleh Mohammed

    1986-12-01

    Energy changes in a head-on collision between two unequal Plummer model stellar systems (galaxies) are studied analytically under the impulsive approximation. The variation of the disruptive effects within and the mass escape from systems widely differing in mass and scalelength ratios are determined, and some physical implications regarding the dynamical stability of the systems undergoing head-on collisions are indicated. It is found that if two systems differ considerably in size, both systems generally survive the collision if (1) the mass of the bigger is greater than about six times the mass of the smaller and (2) the density of the smaller is more than about twenty-five times the entity of the bigger system, when the velocity at minimum separation is equal to the parabolic velocity of escape.

  8. Blade number impact on pressure and performance of archimedes screw turbine using CFD

    NASA Astrophysics Data System (ADS)

    Maulana, Muhammad Ilham; Syuhada, Ahmad; Nawawi, Muhammad

    2018-02-01

    Many rivers in Indonesia can be used as source of mini/micro hydro power plant using low head turbine. The most suitable type of turbine used in fluid flow with low head is the Archimedes screw turbine. The Archimedes screw hydro turbine is a relative newcomer to the small-scale hydropower that can work efficiently on heads as low as 10 meter. In this study, the performance of Archimedes water turbines that has different blade numbers that are thoroughly evaluated to obtain proper blade configuration. For this purpose, numerical simulations are used to predict the pressure changes that occur along the turbine. The simulation results show that turbines with an amount of two blades have more sloping pressure distribution so that it has better stability.

  9. Bone conduction responses of middle ear structures in Thiel embalmed heads

    NASA Astrophysics Data System (ADS)

    Arnold, Andreas; Stieger, Christof; Caversaccio, Marco; Kompis, Martin; Guignard, Jérémie

    2015-12-01

    Thiel-embalmed human whole-head specimens offer a promising alternative model for bone conduction (BC) studies of middle ear structures. In this work we present the Thiel model's linearity and stability over time as well as its possible use in the study of a fixed ossicle chain. Using laser Doppler vibrometry (LDV), the motion of the retroauricular skull, the promontory, the stapes footplate and the round window (RW) were measured. A bone-anchored hearing aid stimulated the ears with step sinus tones logarithmically spread between 0.1 and 10 kHz. Linearity of the model was verified using input levels in steps of 10 dBV. The stability of the Thiel model over time was examined with measurements repeated after hours and weeks. The influence of a cement-fixed stapes was assessed. The middle ear elements measured responded linearly in amplitude for the applied input levels (100, 32.6, and 10 mV). The variability of measurements for both short- (2 h) and long-term (4-16 weeks) repetitions in the same ear was lower than the interindividual difference. The fixation of the stapes induced a lowered RW displacement for frequencies near 750 Hz (-4 dB) and an increased displacement for frequencies above 1 kHz (max. +3.7 dB at 4 kHz). LDV assessment of BC-induced middle ear motion in Thiel heads can be performed with stable results. The vibratory RW response is affected by the fixation of the stapes, indicating a measurable effect of ossicle chain inertia on BC response in Thiel embalmed heads.

  10. Reliability and Normative Data for the Dynamic Visual Acuity Test for Vestibular Screening.

    PubMed

    Riska, Kristal M; Hall, Courtney D

    2016-06-01

    The purpose of this study was to determine reliability of computerized dynamic visual acuity (DVA) testing and to determine reference values for younger and older adults. A primary function of the vestibular system is to maintain gaze stability during head motion. The DVA test quantifies gaze stabilization with the head moving versus stationary. Commercially available computerized systems allow clinicians to incorporate DVA into their assessment; however, information regarding reliability and normative values of these systems is sparse. Forty-six healthy adults, grouped by age, with normal vestibular function were recruited. Each participant completed computerized DVA testing including static visual acuity, minimum perception time, and DVA using the NeuroCom inVision System. Testing was performed by two examiners in the same session and then repeated at a follow-up session 3 to 14 days later. Intraclass correlation coefficients (ICCs) were used to determine inter-rater and test-retest reliability. ICCs for inter-rater reliability ranged from 0.323 to 0.937 and from 0.434 to 0.909 for horizontal and vertical head movements, respectively. ICCs for test-retest reliability ranged from 0.154 to 0.856 and from 0.377 to 0.9062 for horizontal and vertical head movements, respectively. Overall, raw scores (left/right DVA and up/down DVA) were more reliable than DVA loss scores. Reliability of a commercially available DVA system has poor-to-fair reliability for DVA loss scores. The use of a convergence paradigm and not incorporating the forced choice paradigm may contribute to poor reliability.

  11. Validation of simplified centre of mass models during gait in individuals with chronic stroke.

    PubMed

    Huntley, Andrew H; Schinkel-Ivy, Alison; Aqui, Anthony; Mansfield, Avril

    2017-10-01

    The feasibility of using a multiple segment (full-body) kinematic model in clinical gait assessment is difficult when considering obstacles such as time and cost constraints. While simplified gait models have been explored in healthy individuals, no such work to date has been conducted in a stroke population. The aim of this study was to quantify the errors of simplified kinematic models for chronic stroke gait assessment. Sixteen individuals with chronic stroke (>6months), outfitted with full body kinematic markers, performed a series of gait trials. Three centre of mass models were computed: (i) 13-segment whole-body model, (ii) 3 segment head-trunk-pelvis model, and (iii) 1 segment pelvis model. Root mean squared error differences were compared between models, along with correlations to measures of stroke severity. Error differences revealed that, while both models were similar in the mediolateral direction, the head-trunk-pelvis model had less error in the anteroposterior direction and the pelvis model had less error in the vertical direction. There was some evidence that the head-trunk-pelvis model error is influenced in the mediolateral direction for individuals with more severe strokes, as a few significant correlations were observed between the head-trunk-pelvis model and measures of stroke severity. These findings demonstrate the utility and robustness of the pelvis model for clinical gait assessment in individuals with chronic stroke. Low error in the mediolateral and vertical directions is especially important when considering potential stability analyses during gait for this population, as lateral stability has been previously linked to fall risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Countermanding eye-head gaze shifts in humans: marching orders are delivered to the head first.

    PubMed

    Corneil, Brian D; Elsley, James K

    2005-07-01

    The countermanding task requires subjects to cancel a planned movement on appearance of a stop signal, providing insights into response generation and suppression. Here, we studied human eye-head gaze shifts in a countermanding task with targets located beyond the horizontal oculomotor range. Consistent with head-restrained saccadic countermanding studies, the proportion of gaze shifts on stop trials increased the longer the stop signal was delayed after target presentation, and gaze shift stop-signal reaction times (SSRTs: a derived statistic measuring how long it takes to cancel a movement) averaged approximately 120 ms across seven subjects. We also observed a marked proportion of trials (13% of all stop trials) during which gaze remained stable but the head moved toward the target. Such head movements were more common at intermediate stop signal delays. We never observed the converse sequence wherein gaze moved while the head remained stable. SSRTs for head movements averaged approximately 190 ms or approximately 70-75 ms longer than gaze SSRTs. Although our findings are inconsistent with a single race to threshold as proposed for controlling saccadic eye movements, movement parameters on stop trials attested to interactions consistent with a race model architecture. To explain our data, we tested two extensions to the saccadic race model. The first assumed that gaze shifts and head movements are controlled by parallel but independent races. The second model assumed that gaze shifts and head movements are controlled by a single race, preceded by terminal ballistic intervals not under inhibitory control, and that the head-movement branch is activated at a lower threshold. Although simulations of both models produced acceptable fits to the empirical data, we favor the second alternative as it is more parsimonious with recent findings in the oculomotor system. Using the second model, estimates for gaze and head ballistic intervals were approximately 25 and 90 ms, respectively, consistent with the known physiology of the final motor paths. Further, the threshold of the head movement branch was estimated to be 85% of that required to activate gaze shifts. From these results, we conclude that a commitment to a head movement is made in advance of gaze shifts and that the comparative SSRT differences result primarily from biomechanical differences inherent to eye and head motion.

  13. Static and dynamic posture control in postlingual cochlear implanted patients: effects of dual-tasking, visual and auditory inputs suppression

    PubMed Central

    Bernard-Demanze, Laurence; Léonard, Jacques; Dumitrescu, Michel; Meller, Renaud; Magnan, Jacques; Lacour, Michel

    2014-01-01

    Posture control is based on central integration of multisensory inputs, and on internal representation of body orientation in space. This multisensory feedback regulates posture control and continuously updates the internal model of body's position which in turn forwards motor commands adapted to the environmental context and constraints. The peripheral localization of the vestibular system, close to the cochlea, makes vestibular damage possible following cochlear implant (CI) surgery. Impaired vestibular function in CI patients, if any, may have a strong impact on posture stability. The simple postural task of quiet standing is generally paired with cognitive activity in most day life conditions, leading therefore to competition for attentional resources in dual-tasking, and increased risk of fall particularly in patients with impaired vestibular function. This study was aimed at evaluating the effects of postlingual cochlear implantation on posture control in adult deaf patients. Possible impairment of vestibular function was assessed by comparing the postural performance of patients to that of age-matched healthy subjects during a simple postural task performed in static (stable platform) and dynamic (platform in translation) conditions, and during dual-tasking with a visual or auditory memory task. Postural tests were done in eyes open (EO) and eyes closed (EC) conditions, with the CI activated (ON) or not (OFF). Results showed that the postural performance of the CI patients strongly differed from the controls, mainly in the EC condition. The CI patients showed significantly reduced limits of stability and increased postural instability in static conditions. In dynamic conditions, they spent considerably more energy to maintain equilibrium, and their head was stabilized neither in space nor on trunk: they behaved dynamically without vision like an inverted pendulum while the controls showed a whole body rigidification strategy. Hearing (prosthesis on) as well as dual-tasking did not really improve the dynamic postural performance of the CI patients. We conclude that CI patients become strongly visual dependent mainly in challenging postural conditions, a result they have to be awarded of particularly when getting older. PMID:24474907

  14. Static and dynamic posture control in postlingual cochlear implanted patients: effects of dual-tasking, visual and auditory inputs suppression.

    PubMed

    Bernard-Demanze, Laurence; Léonard, Jacques; Dumitrescu, Michel; Meller, Renaud; Magnan, Jacques; Lacour, Michel

    2013-01-01

    Posture control is based on central integration of multisensory inputs, and on internal representation of body orientation in space. This multisensory feedback regulates posture control and continuously updates the internal model of body's position which in turn forwards motor commands adapted to the environmental context and constraints. The peripheral localization of the vestibular system, close to the cochlea, makes vestibular damage possible following cochlear implant (CI) surgery. Impaired vestibular function in CI patients, if any, may have a strong impact on posture stability. The simple postural task of quiet standing is generally paired with cognitive activity in most day life conditions, leading therefore to competition for attentional resources in dual-tasking, and increased risk of fall particularly in patients with impaired vestibular function. This study was aimed at evaluating the effects of postlingual cochlear implantation on posture control in adult deaf patients. Possible impairment of vestibular function was assessed by comparing the postural performance of patients to that of age-matched healthy subjects during a simple postural task performed in static (stable platform) and dynamic (platform in translation) conditions, and during dual-tasking with a visual or auditory memory task. Postural tests were done in eyes open (EO) and eyes closed (EC) conditions, with the CI activated (ON) or not (OFF). Results showed that the postural performance of the CI patients strongly differed from the controls, mainly in the EC condition. The CI patients showed significantly reduced limits of stability and increased postural instability in static conditions. In dynamic conditions, they spent considerably more energy to maintain equilibrium, and their head was stabilized neither in space nor on trunk: they behaved dynamically without vision like an inverted pendulum while the controls showed a whole body rigidification strategy. Hearing (prosthesis on) as well as dual-tasking did not really improve the dynamic postural performance of the CI patients. We conclude that CI patients become strongly visual dependent mainly in challenging postural conditions, a result they have to be awarded of particularly when getting older.

  15. Design and motion control of bioinspired humanoid robot head from servo motors toward artificial muscles

    NASA Astrophysics Data System (ADS)

    Almubarak, Yara; Tadesse, Yonas

    2017-04-01

    The potential applications of humanoid robots in social environments, motivates researchers to design, and control biomimetic humanoid robots. Generally, people are more interested to interact with robots that have similar attributes and movements to humans. The head is one of most important part of any social robot. Currently, most humanoid heads use electrical motors, pneumatic actuators, and shape memory alloy (SMA) actuators for actuation. Electrical and pneumatic actuators take most of the space and would cause unsmooth motions. SMAs are expensive to use in humanoids. Recently, in many robotic projects, Twisted and Coiled Polymer (TCP) artificial muscles are used as linear actuators which take up little space compared to the motors. In this paper, we will demonstrate the designing process and motion control of a robotic head with TCP muscles. Servo motors and artificial muscles are used for actuating the head motion, which have been controlled by a cost efficient ARM Cortex-M7 based development board. A complete comparison between the two actuators is presented.

  16. Unexplained head tilt following surgical treatment of congenital esotropia: a postural manifestation of dissociated vertical divergence

    PubMed Central

    Brodsky, M C; Jenkins, R; Nucci, P

    2004-01-01

    Background: Strabismus surgery for congenital esotropia can be complicated by the development of a postoperative head tilt. Purpose: To determine the pathophysiology of acquired head tilting following horizontal realignment of the eyes in children with congenital esotropia. Materials and methods: Retrospective analysis of nine children with congenital esotropia who developed unexplained head tilts following horizontal realignment of the eyes. Results: Shortly after strabismus surgery, each child developed a head tilt in association with asymmetrical dissociated vertical divergence (DVD). Five children maintained a head tilt toward the side of the fixing eye (group 1), which did not serve to control the DVD. Four children maintained a head tilt toward the side of the hyperdeviating eye, which served to control the DVD (group 2). Children in group 2 had earlier horizontal muscle surgery and developed better stereopsis than those in group 1, suggesting that the higher degree of single binocular vision and stereopsis in these children may have led to a compensatory torticollis to control an asymmetrical DVD. Conclusions: The onset of an unexpected head tilt after congenital esotropia surgery is usually a postural manifestation of asymmetrical DVD. In this setting, a head tilt toward the side of the fixing eye corresponds with a postural manifestation of the underlying central vestibular imbalance that produces DVD, while a head tilt toward the side of the hyperdeviating eye serves to counteract the hyperdeviation and stabilise binocular vision. PMID:14736789

  17. Effectiveness of a handwriting readiness program in head start: a two-group controlled trial.

    PubMed

    Lust, Carol A; Donica, Denise K

    2011-01-01

    This study measured skill improvement in prewriting skills, kindergarten readiness, first-name writing, and handwriting-nonspecific fine motor skills of students at Head Start who participated in Handwriting Without Tears-Get Set for School (HWT-GSS) programming. We conducted a two-group, nonrandomized controlled trial using a pretest-posttest design at a rural Head Start. The effectiveness of adding the HWT-GSS curriculum in one preschool classroom was compared with a control classroom. On posttesting, the experimental group made significant improvements compared with the control group in prewriting, kindergarten readiness, and fine motor skills. Both groups made significant improvements between pretesting and posttesting in prewriting, first name writing, and school readiness. Adding HWT-GSS to the Head Start program would be beneficial in improving handwriting readiness skills.

  18. School Readiness in Children Living in Non-Parental Care: Impacts of Head Start

    ERIC Educational Resources Information Center

    Lipscomb, Shannon T.; Pratt, Megan E.; Schmitt, Sara A.; Pears, Katherine C.; Kim, Hyoun K.

    2013-01-01

    The current study examines the effects of Head Start on the development of school readiness outcomes for children living in non-parental care. Data were obtained from the Head Start Impact Study, a randomized controlled trial of Head Start conducted with a nationally representative sample of Head Start programs and families. The sample included…

  19. Biomechanical Comparison of 3 Inferiorly Directed Versus 3 Superiorly Directed Locking Screws on Stability in a 3-Part Proximal Humerus Fracture Model.

    PubMed

    Donohue, David M; Santoni, Brandon G; Stoops, T Kyle; Tanner, Gregory; Diaz, Miguel A; Mighell, Mark

    2018-06-01

    To quantify the stability of 3 points of inferiorly directed versus 3 points of superiorly directed locking screw fixation compared with the full contingent of 6 points of locked screw fixation in the treatment of a 3-part proximal humerus fracture. A standardized 3-part fracture was created in 10 matched pairs (experimental groups) and 10 nonmatched humeri (control group). Osteosynthesis was performed using 3 locking screws in the superior hemisphere of the humeral head (suspension), 3 locking screws in the inferior hemisphere (buttress), or the full complement of 6 locking screws (control). Specimens were tested in varus cantilever bending (7.5 Nm) to 10,000 cycles or failure. Construct survival (%) and the cycles to failure were compared. Seven of 10 controls survived the 10,000-cycle runout (70%: 8193 average cycles to failure). No experimental constructs survived the 10,000-cycle runout. Suspension and buttress screw groups failed an average of 331 and 516 cycles, respectively (P = 1.00). The average number of cycles to failure and the number of humeri surviving the 10,000-cycle runout were greater in the control group than in the experimental groups (P ≤ 0.006). Data support the use of a full contingent of 6 points of locking screw fixation over 3 superior or 3 inferior points of fixation in the treatment of a 3-part proximal humerus fracture with a locking construct. No biomechanical advantage to the 3 buttress or 3 suspension screws used in isolation was observed.

  20. Regulation of dynamic postural control to attend manual steadiness constraints.

    PubMed

    Teixeira, Luis Augusto; Coutinho, Joane Figueiredo Serpa; Coelho, Daniel Boari

    2018-05-02

    In daily living activities, performance of spatially accurate manual movements in upright stance depends on postural stability. In the present investigation, we aimed to evaluate the effect of the required manual steadiness (task constraint) on the regulation of dynamic postural control. A single group of young participants (n=20) were evaluated in the performance of a dual posturo-manual task of balancing on a platform oscillating in sinusoidal translations at 0.4 Hz (low) or 1 Hz (high) frequencies while stabilizing a cylinder on a handheld tray. Manual task constraint was manipulated by comparing the conditions of keeping the cylinder stationary on its flat or round side, corresponding to low and high manual task constraints, respectively. Results showed that in the low oscillation frequency the high manual task constraint led to lower oscillation amplitudes of the head, center of mass, and tray, in addition to higher relative phase values between ankle/hip-shoulder oscillatory rotations and between center of mass/center of pressure-feet oscillations as compared to values observed in the low manual task constraint. Further analyses showed that the high manual task constraint also affected variables related to both postural (increased amplitudes of center of pressure oscillation) and manual (increased amplitude of shoulder rotations) task components in the high oscillation frequency. These results suggest that control of a dynamic posturo-manual task is modulated in distinct parameters to attend the required manual steadiness in a complex and flexible way.

  1. 77 FR 47493 - DMH Trust fbo Martha M. Head-Acquisition of Control Exemption-Red River Valley & Western Railroad...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-08

    ... Martha M. Head--Acquisition of Control Exemption-- Red River Valley & Western Railroad and Rutland Line, Inc. DMH Trust fbo Martha M. Head (the Trust), a noncarrier, has filed a verified notice of exemption...\\ both Class III rail carriers. \\1\\ RLI is a wholly owned subsidiary of RRVW. According to the Trust...

  2. A Microswitch-Cluster Program to Foster Adaptive Responses and Head Control in Students with Multiple Disabilities: Replication and Validation Assessment

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Oliva, Doretta; Gatti, Michela; Manfredi, Francesco; Megna, Gianfranco; La Martire, Maria L.; Tota, Alessia; Smaldone, Angela; Groeneweg, Jop

    2008-01-01

    A program relying on microswitch clusters (i.e., combinations of microswitches) and preferred stimuli was recently developed to foster adaptive responses and head control in persons with multiple disabilities. In the last version of this program, preferred stimuli (a) are scheduled for adaptive responses occurring in combination with head control…

  3. Ulnar Rotation Osteotomy for Congenital Radial Head Dislocation.

    PubMed

    Liu, Ruiyu; Miao, Wusheng; Mu, Mingchao; Wu, Ge; Qu, Jining; Wu, Yongtao

    2015-09-01

    To evaluate an ulnar rotation osteotomy for congenital anterior dislocation of the radial head. Nine patients (5 boys and 4 girls aged 6 to 13 years) with congenital anterior dislocation of the radial head were treated with ulnar rotation osteotomy. Magnetic resonance imaging of the elbow showed the proximal radioulnar joint on the anterior-lateral side of the ulna rather than on the lateral side in patients with congenital anterior dislocation of the radial head. On the basis of this finding, we performed an osteotomy on the ulna and laterally rotated the proximal radioulnar joint achieving radial head reduction and restoring the anatomical relationship between the radial head and the capitellum. Clinical and radiographical evaluation of the elbow was performed before surgery and at postoperative follow-up. All patients were followed for 13 to 45 months after surgery. Elbow radiography showed that the radiocapitellar joint was reduced in all patients at the last follow-up visit and that the carrying angle was decreased relative to that in the preoperative condition. Elbow stability and the range of elbow flexion motion were improved at the last follow-up. We did not observe ulnar osteotomy site nonunion or elbow osteoarthritis in these patients. Furthermore, radial head dislocation did not recur. At early follow-up, ulnar rotation osteotomy was a safe and effective method for the treatment of congenital anterior dislocation of the radial head. Therapeutic IV. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. [Treatment of beginning juvenile detachment of the femoral head, taking growth of the femoral neck into account (author's transl)].

    PubMed

    Engelhardt, P

    1979-10-01

    Prevention of further detachment is the primary aim in the immediate treatment of beginning juvenile detachment of the femoral head. Screwing of the epiphysis of the head, first introduced by M. E. Mueller (1965), has proved successful. Besides providing immediate mechanical stability, this method, however, results in premature ossification of the joint of the femoral neck. Epiphysiodesis has a particularly unfavourable effect in early childhood, because it inhibits proper growth of the leg and development of the mechanism of the hip joint on account of the shortened femoral neck. Spiking of the epiphysis with Krischner screw wires guarantees safe fixation of the epiphyseal head on the one hand, and sufficient freedom of femoral neck growth on the other. Surgical treatment requires knowledge of the changed hip joint anatomy of the child. Preoperative planning via drawing to determine the length and position of the implantate on the basis of standardised x-ray films, will help to prevent operative failures.

  5. Dynamic Visual Acuity: a Functionally Relevant Research Tool

    NASA Technical Reports Server (NTRS)

    Peters, Brian T.; Brady, Rachel A.; Miller, Chris A.; Mulavara, Ajitkumar P.; Wood, Scott J.; Cohen, Helen S.; Bloomberg, Jacob J.

    2010-01-01

    Coordinated movements between the eyes and head are required to maintain a stable retinal image during head and body motion. The vestibulo-ocular reflex (VOR) plays a significant role in this gaze control system that functions well for most daily activities. However, certain environmental conditions or interruptions in normal VOR function can lead to inadequate ocular compensation, resulting in oscillopsia, or blurred vision. It is therefore possible to use acuity to determine when the environmental conditions, VOR function, or the combination of the two is not conductive for maintaining clear vision. Over several years we have designed and tested several tests of dynamic visual acuity (DVA). Early tests used the difference between standing and walking acuity to assess decrements in the gaze stabilization system after spaceflight. Supporting ground-based studies measured the responses from patients with bilateral vestibular dysfunction and explored the effects of visual target viewing distance and gait cycle events on walking acuity. Results from these studies show that DVA is affected by spaceflight, is degraded in patients with vestibular dysfunction, changes with target distance, and is not consistent across the gait cycle. We have recently expanded our research to include studies in which seated subjects are translated or rotated passively. Preliminary results from this work indicate that gaze stabilization ability may differ between similar active and passive conditions, may change with age, and can be affected by the location of the visual target with respect to the axis of motion. Use of DVA as a diagnostic tool is becoming more popular but the functional nature of the acuity outcome measure also makes it ideal for identifying conditions that could lead to degraded vision. By doing so, steps can be taken to alter the problematic environments to improve the man-machine interface and optimize performance.

  6. Prospective, Head-to-Head Study of Three Computerized Neurocognitive Assessment Tools (CNTs): Reliability and Validity for the Assessment of Sport-Related Concussion.

    PubMed

    Nelson, Lindsay D; LaRoche, Ashley A; Pfaller, Adam Y; Lerner, E Brooke; Hammeke, Thomas A; Randolph, Christopher; Barr, William B; Guskiewicz, Kevin; McCrea, Michael A

    2016-01-01

    Limited data exist comparing the performance of computerized neurocognitive tests (CNTs) for assessing sport-related concussion. We evaluated the reliability and validity of three CNTs-ANAM, Axon Sports/Cogstate Sport, and ImPACT-in a common sample. High school and collegiate athletes completed two CNTs each at baseline. Concussed (n=165) and matched non-injured control (n=166) subjects repeated testing within 24 hr and at 8, 15, and 45 days post-injury. Roughly a quarter of each CNT's indices had stability coefficients (M=198 day interval) over .70. Group differences in performance were mostly moderate to large at 24 hr and small by day 8. The sensitivity of reliable change indices (RCIs) was best at 24 hr (67.8%, 60.3%, and 47.6% with one or more significant RCIs for ImPACT, Axon, and ANAM, respectively) but diminished to near the false positive rates thereafter. Across time, the CNTs' sensitivities were highest in those athletes who became asymptomatic within 1 day before neurocognitive testing but was similar to the tests' false positive rates when including athletes who became asymptomatic several days earlier. Test-retest reliability was similar among these three CNTs and below optimal standards for clinical use on many subtests. Analyses of group effect sizes, discrimination, and sensitivity and specificity suggested that the CNTs may add incrementally (beyond symptom scores) to the identification of clinical impairment within 24 hr of injury or within a short time period after symptom resolution but do not add significant value over symptom assessment later. The rapid clinical recovery course from concussion and modest stability probably jointly contribute to limited signal detection capabilities of neurocognitive tests outside a brief post-injury window. (JINS, 2016, 22, 24-37).

  7. Prospective, Head-to-Head Study of Three Computerized Neurocognitive Assessment Tools (CNTs): Reliability and Validity for the Assessment of Sport-Related Concussion

    PubMed Central

    Nelson, Lindsay D.; LaRoche, Ashley A.; Pfaller, Adam Y.; Lerner, E. Brooke; Hammeke, Thomas A.; Randolph, Christopher; Barr, William B.; Guskiewicz, Kevin; McCrea, Michael A.

    2016-01-01

    Limited data exist comparing the performance of computerized neurocognitive tests (CNTs) for assessing sport-related concussion. We evaluated the reliability and validity of three CNTs—ANAM, Axon Sports/Cogstate Sport, and ImPACT—in a common sample. High school and collegiate athletes completed two CNTs each at baseline. Concussed (n = 165) and matched non-injured control (n = 166) subjects repeated testing within 24 hr and at 8, 15, and 45 days post-injury. Roughly a quarter of each CNT's indices had stability coefficients (M = 198 day interval) over .70. Group differences in performance were mostly moderate to large at 24 hr and small by day 8. The sensitivity of reliable change indices (RCIs) was best at 24 hr (67.8%, 60.3%, and 47.6% with one or more significant RCIs for ImPACT, Axon, and ANAM, respectively) but diminished to near the false positive rates thereafter. Across time, the CNTs' sensitivities were highest in those athletes who became asymptomatic within 1 day before neurocognitive testing but was similar to the tests' false positive rates when including athletes who became asymptomatic several days earlier. Test–retest reliability was similar among these three CNTs and below optimal standards for clinical use on many subtests. Analyses of group effect sizes, discrimination, and sensitivity and specificity suggested that the CNTs may add incrementally (beyond symptom scores) to the identification of clinical impairment within 24 hr of injury or within a short time period after symptom resolution but do not add significant value over symptom assessment later. The rapid clinical recovery course from concussion and modest stability probably jointly contribute to limited signal detection capabilities of neurocognitive tests outside a brief post-injury window. PMID:26714883

  8. Symptoms from repeated intentional and unintentional head impact in soccer players

    PubMed Central

    Stewart, Walter F.; Kim, Namhee; Ifrah, Chloe S.; Lipton, Richard B.; Bachrach, Tamar A.; Zimmerman, Molly E.; Kim, Mimi

    2017-01-01

    Objective: To determine the rate and differential contribution of heading vs unintentional head impacts (e.g., head to head, goal post) to CNS symptoms in adult amateur soccer players. Methods: Amateur soccer players completed baseline and serial on-line 2-week recall questionnaires (HeadCount) and reported (1) soccer practice and games, (2) heading and unintentional soccer head trauma, and (3) frequency and severity (mild to very severe) of CNS symptoms. For analysis, CNS symptoms were affirmed if one or more moderate, severe, or very severe episodes were reported in a 2-week period. Repeated measures logistic regression was used to assess if 2-week heading exposure (i.e., 4 quartiles) or unintentional head impacts (i.e., 0, 1, 2+) were associated with CNS symptoms. Results: A total of 222 soccer players (79% male) completed 470 HeadCount questionnaires. Mean (median) heading/2 weeks was 44 (18) for men and 27 (9.5) for women. One or more unintentional head impacts were reported by 37% of men and 43% of women. Heading-related symptoms were reported in 20% (93 out of 470) of the HeadCounts. Heading in the highest quartile was significantly associated with CNS symptoms (odds ratio [OR] 3.17, 95% confidence interval [CI] 1.57–6.37) when controlling for unintentional exposure. Those with 2+ unintentional exposures were at increased risk for CNS symptoms (OR 6.09, 95% CI 3.33–11.17) as were those with a single exposure (OR 2.98, 95% CI 1.69–5.26) when controlling for heading. Conclusions: Intentional (i.e., heading) and unintentional head impacts are each independently associated with moderate to very severe CNS symptoms. PMID:28148633

  9. Hemodynamic response to exercise and head-up tilt of patients implanted with a rotary blood pump: a computational modeling study.

    PubMed

    Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton

    2015-02-01

    The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and substantially reduced the arterial pressure upon HUT. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. Stable J-aggregation enabled dual photoacoustic and fluorescence nanoparticles for intraoperative cancer imaging

    NASA Astrophysics Data System (ADS)

    Shakiba, Mojdeh; Ng, Kenneth K.; Huynh, Elizabeth; Chan, Harley; Charron, Danielle M.; Chen, Juan; Muhanna, Nidal; Foster, F. Stuart; Wilson, Brian C.; Zheng, Gang

    2016-06-01

    J-aggregates display nanoscale optical properties which enable their use in fluorescence and photoacoustic imaging applications. However, control over their optical properties in an in vivo setting is hampered by the conformational lability of the J-aggregate structure in complex biological environments. J-aggregating nanoparticles (JNP) formed by self-assembly of bacteriopheophorbide-lipid (Bchl-lipid) in lipid nanovesicles represents a novel strategy to stabilize J-aggregates for in vivo bioimaging applications. We find that 15 mol% Bchl-lipid embedded within a saturated phospholipid bilayer vesicle was optimal in terms of maximizing Bchl-lipid dye loading, while maintaining a spherical nanoparticle morphology and retaining spectral properties characteristic of J-aggregates. The addition of cholesterol maintains the stability of the J-aggregate absorption band for up to 6 hours in the presence of 90% FBS. In a proof-of-concept experiment, we successfully applied JNPs as a fluorescence contrast agent for real-time intraoperative detection of metastatic lymph nodes in a rabbit head-and-neck cancer model. Lymph node metastasis delineation was further verified by visualizing the JNP within the excised lymph node using photoacoustic imaging. Using JNPs, we demonstrate the possibility of using J-aggregates as fluorescence and photoacoustic contrast agents and may potentially spur the development of other nanomaterials that can stably induce J-aggregation for in vivo cancer bioimaging applications.J-aggregates display nanoscale optical properties which enable their use in fluorescence and photoacoustic imaging applications. However, control over their optical properties in an in vivo setting is hampered by the conformational lability of the J-aggregate structure in complex biological environments. J-aggregating nanoparticles (JNP) formed by self-assembly of bacteriopheophorbide-lipid (Bchl-lipid) in lipid nanovesicles represents a novel strategy to stabilize J-aggregates for in vivo bioimaging applications. We find that 15 mol% Bchl-lipid embedded within a saturated phospholipid bilayer vesicle was optimal in terms of maximizing Bchl-lipid dye loading, while maintaining a spherical nanoparticle morphology and retaining spectral properties characteristic of J-aggregates. The addition of cholesterol maintains the stability of the J-aggregate absorption band for up to 6 hours in the presence of 90% FBS. In a proof-of-concept experiment, we successfully applied JNPs as a fluorescence contrast agent for real-time intraoperative detection of metastatic lymph nodes in a rabbit head-and-neck cancer model. Lymph node metastasis delineation was further verified by visualizing the JNP within the excised lymph node using photoacoustic imaging. Using JNPs, we demonstrate the possibility of using J-aggregates as fluorescence and photoacoustic contrast agents and may potentially spur the development of other nanomaterials that can stably induce J-aggregation for in vivo cancer bioimaging applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/C5NR08165C

  11. Head Start’s Impact is Contingent on Alternative Type of Care in Comparison Group

    PubMed Central

    Brooks-Gunn, Jeanne; Waldfogel, Jane

    2014-01-01

    Using data (n = 3,790 with 2,119 in the 3-year-old cohort and 1,671 in the 4-year-old cohort) from 353 Head Start centers in the Head Start Impact Study, the only large-scale randomized experiment in Head Start history, this paper examined the impact of Head Start on children’s cognitive and parent-reported social-behavioral outcomes through first grade contingent on the child care arrangements used by children who were randomly assigned to the control group (i.e., parental care, relative/non-relative care, another Head Start program, or other center-based care). A principal score matching approach was adopted to identify children assigned to Head Start who were similar to children in the control group with a specific care arrangement. Overall, the results showed that the effects of Head Start varied substantially contingent on the alternative child care arrangements. Compared to children in parental care and relative/non-relative care, Head Start participants generally had better cognitive and parent-reported behavioral development, with some benefits of Head Start persisting through first grade; in contrast, few differences were found between Head Start and other center-based care. The results have implications regarding the children for whom Head Start is most beneficial as well as how well Head Start compares to other center-based programs. PMID:25329552

  12. Stabilization of p21 by mTORC1/4E-BP1 predicts clinical outcome of head and neck cancers

    PubMed Central

    Llanos, Susana; García-Pedrero, Juana M.; Morgado-Palacin, Lucia; Rodrigo, Juan P.; Serrano, Manuel

    2016-01-01

    The levels, regulation and prognostic value of p21 in head and neck squamous cell carcinomas (HNSCC) has been puzzling for years. Here, we report a new mechanism of regulation of p21 by the mTORC1/4E-BP1 pathway. We find that non-phosphorylated 4E-BP1 interacts with p21 and induces its degradation. Accordingly, hyper-activation of mTORC1 results in phosphorylation of 4E-BP1 and stabilization of p21. In HNSCC, p21 levels strongly correlate with mTORC1 activity but not with p53 status. Finally, clinical data indicate that HNSCC patients with p21 and phospho-S6-double-positive tumours present a better disease-specific survival. We conclude that over-activation of the mTORC1/4E-BP1/p21 pathway is a frequent and clinically relevant alteration in HNSCC. PMID:26832959

  13. Studies of the vestibulo-ocular reflex on STS 4, 5 and 6

    NASA Technical Reports Server (NTRS)

    Thornton, William E.; Pool, Sam L.; Moore, Thomas P.; Uri, John J.

    1988-01-01

    The vestibulo-ocular reflex (VOR) may be altered by weightlessness. Since this reflex plays a large role in visual stabilization, it was important to document any changes caused by space flight. This is a report on findings on STS-4 through 6 and is part of a larger study of neurosensory adaptation done on STS-4 through 8. Voluntary horizontal head oscillations at 1/3 Hz with amplitude of 30 deg right and left of center were recorded by a potentiometer and compared to eye position recorded by electroculography under the following conditions: eyes open, head fixed, tracking horizontal targets switched 0, 15, and 30 degrees right and left (optokinetic reflex - OKR - and calibration); eyes open and fixed on static external target with oscillation, (vestibulo ocular reflex, eyes closed - VOR EC); eyes open and wearing opaque goggles with target fixed in imagination (vestibulo-ocular reflex, eyes shaded - VOR ES); and eyes open and fixed on a head synchronized target with head oscillation (VOR suppression). No significant changes were found in voluntary head oscillation frequency or amplitude in those with (n=5), and without (n=3), space motion sickness (SMS), with phase of flight or test condition. Variations in head oscillation were too small to have produced detectable changes in test results.

  14. Compliant head probe for positioning electroencephalography electrodes and near-infrared spectroscopy optodes

    NASA Astrophysics Data System (ADS)

    Giacometti, Paolo; Diamond, Solomon G.

    2013-02-01

    A noninvasive head probe that combines near-infrared spectroscopy (NIRS) and electroencephalography (EEG) for simultaneous measurement of neural dynamics and hemodynamics in the brain is presented. It is composed of a compliant expandable mechanism that accommodates a wide range of head size variation and an elastomeric web that maintains uniform sensor contact pressure on the scalp as the mechanism expands and contracts. The design is intended to help maximize optical and electrical coupling and to maintain stability during head movement. Positioning electrodes at the inion, nasion, central, and preauricular fiducial locations mechanically shapes the probe to place 64 NIRS optodes and 65 EEG electrodes following the 10-5 scalp coordinates. The placement accuracy, precision, and scalp pressure uniformity of the sensors are evaluated. A root-mean-squared (RMS) positional precision of 0.89±0.23 mm, percent arc subdivision RMS accuracy of 0.19±0.15%, and mean normal force on the scalp of 2.28±0.88 N at 5 mm displacement were found. Geometric measurements indicate that the probe will accommodate the full range of adult head sizes. The placement accuracy, precision, and uniformity of sensor contact pressure of the proposed head probe are important determinants of data quality in noninvasive brain monitoring with simultaneous NIRS-EEG.

  15. Aqueous Foam Stabilized by Tricationic Amphiphilic Surfactants

    NASA Astrophysics Data System (ADS)

    Heerschap, Seth; Marafino, John; McKenna, Kristin; Caran, Kevin; Feitosa, Klebert; Kevin Caran's Research Group Collaboration

    2015-03-01

    The unique surface properties of amphiphilic molecules have made them widely used in applications where foaming, emulsifying or coating processes are needed. The development of novel architectures with multi-cephalic/tailed molecules have enhanced their anti-bacterial activity in connection with tail length and the nature of the head group. Here we report on the foamability of two triple head double, tail cationic surfactants (M-1,14,14, M-P, 14,14) and a triple head single tail cationic surfactant (M-1,1,14) and compare them with commercially available single headed, single tailed anionic and cationic surfactants (SDS,CTAB and DTAB). The results show that bubble rupture rate decrease with the length of the carbon chain irrespective of head structure. The growth rate of bubbles with short tailed surfactants (SDS) and longer, single tailed tricationic surfactants (M-1,1,14) was shown to be twice as high as those with longer tailed surfactants (CTAB, M-P,14,14, M-1,14,14). This fact was related to the size variation of bubbles, where the foams made with short tail surfactants exhibited higher polydispersivity than those with short tails. This suggests that foams with tricationic amphiphilics are closed linked to their tail length and generally insensitive to their head structure.

  16. Bioactivity of Argentinean Essential Oils Against Permethrin-Resistant Head Lice, Pediculus humanus capitis

    PubMed Central

    Toloza, Ariel C; Zygadlo, Julio; Biurrun, Fernando; Rotman, Alicia; Picollo, María I

    2010-01-01

    Infestation with the head louse, Pediculus humanus capitis De Geer (Phthiraptera: Pediculidae), is one of the most common parasitic infestation of humans worldwide. Traditionally, the main treatment for control of head lice is chemical control that is based in a wide variety of neurotoxic synthetic insecticides. The repeated overuse of these products has resulted in the selection of resistant populations of head lice. Thus, plant-derived insecticides, such as the essential oils seem to be good viable alternatives as some have low toxicity to mammals and are biodegradable. We determined the insecticidal activity of 25 essential oils belonging to several botanical families present in Argentina against permethrin-resistant head lice. Significant differences in fumigant activity against head lice were found among the essential oils from the native and exotic plant species. The most effective essential oils were Cinnamomum porphyrium, followed by Aloysia citriodora (chemotype 2) and Myrcianthes pseudomato, with KT50 values of 1.12, 3.02 and 4.09; respectively. The results indicate that these essential oils are effective and could be incorporated into pediculicide formulations to control head lice infestations once proper formulation and toxicological tests are performed. PMID:21062140

  17. Bioactivity of Argentinean essential oils against permethrin-resistant head lice, Pediculus humanus capitis.

    PubMed

    Toloza, Ariel C; Zygadlo, Julio; Biurrun, Fernando; Rotman, Alicia; Picollo, María I

    2010-01-01

    Infestation with the head louse, Pediculus humanus capitis De Geer (Phthiraptera: Pediculidae), is one of the most common parasitic infestation of humans worldwide. Traditionally, the main treatment for control of head lice is chemical control that is based in a wide variety of neurotoxic synthetic insecticides. The repeated overuse of these products has resulted in the selection of resistant populations of head lice. Thus, plant-derived insecticides, such as the essential oils seem to be good viable alternatives as some have low toxicity to mammals and are biodegradable. We determined the insecticidal activity of 25 essential oils belonging to several botanical families present in Argentina against permethrin-resistant head lice. Significant differences in fumigant activity against head lice were found among the essential oils from the native and exotic plant species. The most effective essential oils were Cinnamomum porphyrium, followed by Aloysia citriodora (chemotype 2) and Myrcianthes pseudomato, with KT(50) values of 1.12, 3.02 and 4.09; respectively. The results indicate that these essential oils are effective and could be incorporated into pediculicide formulations to control head lice infestations once proper formulation and toxicological tests are performed.

  18. Testing the sensitivity of pumpage to increases in surficial aquifer system heads in the Cypress Creek well-field area, West-Central Florida : an optimization technique

    USGS Publications Warehouse

    Yobbi, Dann K.

    2002-01-01

    Tampa Bay depends on ground water for most of the water supply. Numerous wetlands and lakes in Pasco County have been impacted by the high demand for ground water. Central Pasco County, particularly the area within the Cypress Creek well field, has been greatly affected. Probable causes for the decline in surface-water levels are well-field pumpage and a decade-long drought. Efforts are underway to increase surface-water levels by developing alternative sources of water supply, thus reducing the quantity of well-field pumpage. Numerical ground-water flow simulations coupled with an optimization routine were used in a series of simulations to test the sensitivity of optimal pumpage to desired increases in surficial aquifer system heads in the Cypress Creek well field. The ground-water system was simulated using the central northern Tampa Bay ground-water flow model. Pumping solutions for 1987 equilibrium conditions and for a transient 6-month timeframe were determined for five test cases, each reflecting a range of desired target recovery heads at different head control sites in the surficial aquifer system. Results are presented in the form of curves relating average head recovery to total optimal pumpage. Pumping solutions are sensitive to the location of head control sites formulated in the optimization problem and as expected, total optimal pumpage decreased when desired target head increased. The distribution of optimal pumpage for individual production wells also was significantly affected by the location of head control sites. A pumping advantage was gained for test-case formulations where hydraulic heads were maximized in cells near the production wells, in cells within the steady-state pumping center cone of depression, and in cells within the area of the well field where confining-unit leakance is the highest. More water was pumped and the ratio of head recovery per unit decrease in optimal pumpage was more than double for test cases where hydraulic heads are maximized in cells located at or near the production wells. Additionally, the ratio of head recovery per unit decrease in pumpage was about three times more for the area where confining-unit leakance is the highest than for other leakance zone areas of the well field. For many head control sites, optimal heads corresponding to optimal pumpage deviated from the desired target recovery heads. Overall, pumping solutions were constrained by the limiting recovery values, initial head conditions, and by upper boundary conditions of the ground-water flow model.

  19. Relationship between ABO blood groups and head and neck cancer among Greek patients.

    PubMed

    Kakava, Kassiani; Karelas, Ioannis; Koutrafouris, Ioannis; Damianidis, Savvas; Stampouloglou, Paulos; Papadakis, Georgios; Xenos, Antonios; Krania, Foteini; Sarof, Paulos; Tasopoulos, Georgios; Petridis, Nikolaos

    2016-01-01

    We examined the association of ABO blood groups with the different types of head and neck cancers. 195 diagnosed cases and 801 controls were selected from a Greek tertiary cancer center. Information regarding type of head and neck cancer and ABO blood group was collected and registered. The O blood group was found to be most prevalent followed by A, B and AB among the controls, whereas blood group A followed by O, B and AB was most prevalent among cancer patients. The difference among the distribution between the cases and controls was statistically significant in blood group A (p<0.05), whereas blood group A had 1.52-fold higher risk of developing head and neck cancer compared to people of other blood groups. Blood group A was found to be a potential risk factor for the development of head and neck cancers.

  20. A Phase I Clinical Trial of AZD1775 in Combination With Neoadjuvant Weekly Docetaxel and Cisplatin Before Definitive Therapy in Head and Neck Squamous Cell Carcinoma. | Office of Cancer Genomics

    Cancer.gov

    Purpose: The WEE1 tyrosine kinase regulates G2/M transition and maintains genomic stability, particularly in p53-deficient tumors which require DNA repair after genotoxic therapy. There is a need to exploit the role of WEE1 inhibition in head and neck squamous cell carcinoma (HNSCC) mostly driven by tumor-suppressor loss. This completed phase I clinical trial represents the first published clinical experience using the WEE1 inhibitor, AZD1775, with cisplatin and docetaxel.

  1. Facilitation handlings induce increase in electromyographic activity of muscles involved in head control of cerebral palsy children.

    PubMed

    Simon, Anelise de Saldanha; do Pinho, Alexandre Severo; Grazziotin Dos Santos, Camila; Pagnussat, Aline de Souza

    2014-10-01

    This study aimed to investigate the electromyographic (EMG) activation of the main cervical muscles involved in the head control during two postures widely used for the facilitation of head control in children with Cerebral Palsy (CP). A crossover trial involving 31 children with clinical diagnosis of CP and spastic quadriplegia was conducted. Electromyography was used to measure muscular activity in randomized postures. Three positions were at rest: (a) lateral decubitus, (b) ventral decubitus on the floor and (c) ventral decubitus on the wedge. Handlings for facilitating the head control were performed using the hip joint as key point of control in two postures: (a) lateral decubitus and (b) ventral decubitus on wedge. All children underwent standardized handlings, performed by the same researcher with experience in the neurodevelopmental treatment. EMG signal was recorded from muscles involved in the head control (paraspinal and sternocleidomastoid muscles) in sagittal, frontal and transverse planes, at the fourth cervical vertebra (C4), tenth thoracic vertebra (T10) and sternocleidomastoid muscle (SCM) levels. The results showed a significant increase in muscle activation when handling was performed in the lateral decubitus at C4 (P<0.001), T10 (P<0.001) and SCM (P=0.02) levels. A significant higher muscle activation was observed when handling was performed in lateral decubitus when compared to ventral decubitus at C4 level (P<0.001). Handling in ventral decubitus also induced an increase in EMG activation at T10 (P=0.018) and SCM (P=0.004) levels but not at C4 level (P=0.38). In conclusion, handlings performed in both positions may induce the facilitation of head control, as evaluated by the activity of cervical and upper trunk muscles. Handling performed in lateral decubitus may induce a slightly better facilitation of head control. These findings contribute to evidence-based physiotherapy practice for the rehabilitation of severely spastic quadriplegic CP children. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Radial head reconstruction in elbow fracture-dislocation: monopolar or bipolar prosthesis?

    PubMed

    Hartzler, Robert U; Morrey, Bernard F; Steinmann, Scott P; Llusa-Perez, Manuel; Sanchez-Sotelo, Joaquin

    2014-07-01

    Monopolar and bipolar radial head prosthetic arthroplasties have been used successfully to treat elbow fracture-dislocation with unsalvageable radial head fractures. The relative stability of these two designs in different clinical situations is a topic of ongoing investigation. We tested the effects of monopolar and bipolar fixed-neck prosthetic radial head implants on improvement in elbow coronal and axial plane laxity in a terrible triad biomechanical model that accounted for lateral collateral ligament integrity and the presence of a transverse coronoid fracture. Kinematic data were collected on six fresh-frozen cadaveric upper extremities tested with passive motion throughout the flexion arc. Varus and valgus gravity stress were applied with the wrist in neutral position. A lateral collateral ligament reconstruction was simulated. We assessed instability after radial head resection and reconstruction with either a monopolar or bipolar implant in the presence of a transversely fractured (Regan and Morrey Type 2) or fixed coronoid process. With collateral ligament integrity, no difference was detected, with the numbers available, in valgus laxity between implants under valgus stress (p = 1.0). Laxity improvement with each prosthesis was higher when the coronoid was fractured (mean ± SD: monopolar: 7.4° ± 1.6°, p < 0.001; bipolar: 6.4° ± 1.6°, p = 0.003) than when it was fixed (monopolar: 4.0° ± 1.6°, p = 0.02; bipolar: 4.2° ± 1.6°, p = 0.01). With the numbers available, there was no difference in external rotation laxity between implants under valgus stress (p = 1.0). The greatest stabilizing effect of the prostheses occurred when the coronoid was fractured (monopolar: 3.3° ± 1.2°, p = 0.15; bipolar: 3.3° ± 1.2°, p = 0.17). Radial head arthroplasty offered no substantial stability under varus stress for varus or internal rotation laxity. In our terrible triad cadaveric model, coronoid fixation was effective in improving varus laxity with a monopolar or bipolar prosthesis in place. Also, both types of prostheses were effective in improving valgus and external rotation laxity to the elbow, regardless of coronoid status. With collateral ligaments reconstructed, no large kinematic differences were noted between implants regardless of the varus-valgus position or whether the coronoid was fractured or fixed. The data from our cadaveric model support the use of either implant type in terrible triad injuries if the collateral ligaments are intact or reconstructed.

  3. Electrical stimulation of rhesus monkey nucleus reticularis gigantocellularis. II. Effects on metrics and kinematics of ongoing gaze shifts to visual targets.

    PubMed

    Freedman, Edward G; Quessy, Stephan

    2004-06-01

    Saccade kinematics are altered by ongoing head movements. The hypothesis that a head movement command signal, proportional to head velocity, transiently reduces the gain of the saccadic burst generator (Freedman 2001, Biol Cybern 84:453-462) can account for this observation. Using electrical stimulation of the rhesus monkey nucleus reticularis gigantocellularis (NRG) to alter the head contribution to ongoing gaze shifts, two critical predictions of this gaze control hypothesis were tested. First, this hypothesis predicts that activation of the head command pathway will cause a transient reduction in the gain of the saccadic burst generator. This should alter saccade kinematics by initially reducing velocity without altering saccade amplitude. Second, because this hypothesis does not assume that gaze amplitude is controlled via feedback, the added head contribution (produced by NRG stimulation on the side ipsilateral to the direction of an ongoing gaze shift) should lead to hypermetric gaze shifts. At every stimulation site tested, saccade kinematics were systematically altered in a way that was consistent with transient reduction of the gain of the saccadic burst generator. In addition, gaze shifts produced during NRG stimulation were hypermetric compared with control movements. For example, when targets were briefly flashed 30 degrees from an initial fixation location, gaze shifts during NRG stimulation were on average 140% larger than control movements. These data are consistent with the predictions of the tested hypothesis, and may be problematic for gaze control models that rely on feedback control of gaze amplitude, as well as for models that do not posit an interaction between head commands and the saccade burst generator.

  4. Improved local and regional control with radiotherapy for Merkel cell carcinoma of the head and neck.

    PubMed

    Strom, Tobin; Naghavi, Arash O; Messina, Jane L; Kim, Sungjune; Torres-Roca, Javier F; Russell, Jeffery; Sondak, Vernon K; Padhya, Tapan A; Trotti, Andy M; Caudell, Jimmy J; Harrison, Louis B

    2017-01-01

    We hypothesized that radiotherapy (RT) would improve both local and regional control with Merkel cell carcinoma of the head and neck. A single-institution institutional review board-approved study was performed including 113 patients with nonmetastatic Merkel cell carcinoma of the head and neck. Postoperative RT was delivered to the primary tumor bed (71.7% cases) ± draining lymphatics (33.3% RT cases). Postoperative local RT was associated with improved local control (3-year actuarial local control 89.4% vs 68.1%; p = .005; Cox hazard ratio [HR] 0.18; 95% confidence interval [CI] = 0.06-0.55; p = .002). Similarly, regional RT was associated with improved regional control (3-year actuarial regional control 95.0% vs 66.7%; p = .008; Cox HR = 0.09; 95% CI = 0.01-0.69; p = .02). Regional RT played an important role for both clinical node-negative patients (3-year regional control 100% vs 44.7%; p = .03) and clinical/pathological node-positive patients (3-year regional control 90.9% vs 55.6%; p = .047). Local RT was beneficial for all patients with Merkel cell carcinoma of the head and neck, whereas regional RT was beneficial for clinical node-negative and clinical/pathological node-positive patients. © 2016 Wiley Periodicals, Inc. Head Neck 39: 48-55, 2017. © 2016 Wiley Periodicals, Inc.

  5. An investigation of the relationship of drooling with nutrition and head control in individuals with quadriparetic cerebral palsy

    PubMed Central

    Taş, Seda Ayaz; Çankaya, Tamer

    2015-01-01

    [Purpose] The aim of the present study was to investigate the relationship of drooling, nutrition, and head control in individuals with quadriparetic cerebral palsy. [Subjects and Methods] Fifty-six individuals between the ages 2 and 15 diagnosed with spastic quadriparetic cerebral palsy and their families/caretakers were included in the study. Drooling severity and frequency of individuals was evaluated by using the scale developed by Thomas-Stonell and Greenberg (Drooling Severity and Frequency Scale). Individuals having a drooling severity value of 1 were included in the not drooling group (group 2) (n=27). Individuals having a drooling severity of 2, 3, 4, or 5 were included in the drooling group (group 1) (n=29). The evaluations were applied to both groups. [Results] There were significant differences between the two groups in terms of gestational age, nutrition behavior, eating abilities, head control, gagging, nutritional status (inadequate nutrition, normal nutrition, over weight-obese), and low weight. It was established that as head control increased, drooling severity diminished, and as drooling severity increased, BMI index decreased. Independence of eating ability was found to be greater in the group having better drooling control. [Conclusion] In the present study, it was determined that drooling control affected nutritional functions and that drooling control was affected by head control. PMID:26696723

  6. Household-wide ivermectin treatment for head lice in an impoverished community: randomized observer-blinded controlled trial

    PubMed Central

    Pilger, Daniel; Heukelbach, Jorg; Khakban, Adak; Oliveira, Fabiola Araujo; Fengler, Gernot

    2010-01-01

    Abstract Objective To generate evidence on the effectiveness of household-wide treatment for preventing the transmission of pediculosis capitis (head lice) in resource-poor communities. Methods We studied 132 children without head lice who lived in a slum in north-eastern Brazil. We randomized the households of the study participants into an intervention and a control group and prospectively calculated the incidence of infestation with head lice among the children in each group. In the intervention group, all of the children’s family members who lived in the household were treated with ivermectin; in the control group, no family member was treated. We used the χ² test with continuity correction or Fisher’s exact test to compare proportions. We performed survival analysis using Kaplan–Meier estimates with log rank testing and the Mann–Whitney U test to analyse the length of lice-free periods among sentinel children, and we used Cox regression to analyse survival data on a multivariate level. We also carried out a subgroup analysis based on gender. Findings Children in the intervention group remained free from infestation with head lice significantly longer than children in the control group. The median infestation-free period in the intervention group was 24 days (interquartile range, IQR: 11–45), as compared to 14 days (IQR: 11–25) in the control group (P = 0.01). Household-wide treatment with ivermectin proved significantly more effective among boys than among girls (P = 0.005). After treatment with ivermectin, the estimated number of annual episodes of head lice infestation was reduced from 19 to 14 in girls and from 15 to 5 in boys. Female sex and extreme poverty were independent risk factors associated with a shortened disease-free period. Conclusion In an impoverished community, girls and the poorest of the poor are the population groups that are most vulnerable for head lice infestation. To decrease the number of head lice episodes per unit of time, control measures should include the treatment of all household contacts. Mass treatment with ivermectin may reduce the incidence of head lice infestation and associated morbidity in resource-poor communities. PMID:20428365

  7. Household-wide ivermectin treatment for head lice in an impoverished community: randomized observer-blinded controlled trial.

    PubMed

    Pilger, Daniel; Heukelbach, Jorg; Khakban, Adak; Oliveira, Fabiola Araujo; Fengler, Gernot; Feldmeier, Hermann

    2010-02-01

    To generate evidence on the effectiveness of household-wide treatment for preventing the transmission of pediculosis capitis (head lice) in resource-poor communities. We studied 132 children without head lice who lived in a slum in north-eastern Brazil. We randomized the households of the study participants into an intervention and a control group and prospectively calculated the incidence of infestation with head lice among the children in each group. In the intervention group, all of the children's family members who lived in the household were treated with ivermectin; in the control group, no family member was treated. We used the chi(2) test with continuity correction or Fisher's exact test to compare proportions. We performed survival analysis using Kaplan-Meier estimates with log rank testing and the Mann-Whitney U test to analyse the length of lice-free periods among sentinel children, and we used Cox regression to analyse survival data on a multivariate level. We also carried out a subgroup analysis based on gender. Children in the intervention group remained free from infestation with head lice significantly longer than children in the control group. The median infestation-free period in the intervention group was 24 days (interquartile range, IQR: 11-45), as compared to 14 days (IQR: 11-25) in the control group (P = 0.01). Household-wide treatment with ivermectin proved significantly more effective among boys than among girls (P = 0.005). After treatment with ivermectin, the estimated number of annual episodes of head lice infestation was reduced from 19 to 14 in girls and from 15 to 5 in boys. Female sex and extreme poverty were independent risk factors associated with a shortened disease-free period. In an impoverished community, girls and the poorest of the poor are the population groups that are most vulnerable for head lice infestation. To decrease the number of head lice episodes per unit of time, control measures should include the treatment of all household contacts. Mass treatment with ivermectin may reduce the incidence of head lice infestation and associated morbidity in resource-poor communities.

  8. 5 CFR 1320.7 - Agency head and Senior Official responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Agency head and Senior Official... CONTROLLING PAPERWORK BURDENS ON THE PUBLIC § 1320.7 Agency head and Senior Official responsibilities. (a) Except as provided in paragraph (b) of this section, each agency head shall designate a Senior Official...

  9. Primary Grade Teachers' Knowledge and Perceptions of Head Lice.

    ERIC Educational Resources Information Center

    Kirchofer, Gregg M.; Price, James H.; Telljohann, Susan K.

    2001-01-01

    Surveyed primary school teachers regarding knowledge of head lice, self-efficacy in handling head lice, and preferred information sources. Teachers needed more knowledge about head lice. About half had high efficacy expectations regarding their ability to control the spread of lice. Most reported receiving information from school nurses. Knowledge…

  10. Stimuli responsive charge-switchable lipids: Capture and release of nucleic acids.

    PubMed

    Hersey, Joseph S; LaManna, Caroline M; Lusic, Hrvoje; Grinstaff, Mark W

    2016-03-01

    Stimuli responsive lipids, which enable control over the formation, transformation, and disruption of supramolecular assemblies, are of interest for biosensing, diagnostics, drug delivery, and basic transmembrane protein studies. In particular, spatiotemporal control over a supramolecular structure can be achieved using light activated compounds to induce significant supramolecular rearrangements. As such, a family of cationic lipids are described which undergo a permanent switch in charge upon exposure to 365 nm ultraviolet (UV) light to enable the capture of negatively charged nucleic acids within the self-assembled supramolecular structure of the lipids and subsequent release of these macromolecules upon exposure to UV light and disruption of the assemblies. The lipids are composed of either two different tripeptide head groups, Lysine-Glycine-Glycine (KGG) and Glycine-Glycine-Glycine (GGG) and three different hydrocarbon chain lengths (C6, C10, or C14) terminated by a UV light responsive 1-(2-nitrophenyl)ethanol (NPE) protected carboxylic acid. The photolysis of the NPE protected lipid is measured as a function of time, and the resulting changes in net molecular charge are observed using zeta potential analysis for each head group and chain length combination. A proof of concept study for the capture and release of both linear DNA (calf thymus) and siRNA is presented using an ethidium bromide quenching assay where a balance between binding affinity and supramolecular stability are found to be the key to optimal nucleic acid capture and release. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Healthy Active Duty Military with Lifetime Experience of Mild Traumatic Brain Injury Exhibits Subtle Deficits in Sensory Reactivity and Sensory Integration During Static Balance.

    PubMed

    Wright, W Geoffrey; Handy, Justin D; Avcu, Pelin; Ortiz, Alejandro; Haran, F Jay; Doria, Michael; Servatius, Richard J

    2018-03-01

    Postural control and stress reactivity were investigated in active duty coast guard personnel to determine whether they are sensitive to lifetime effects of mild traumatic brain injury (mTBI). A custom-designed and validated virtual reality-based computerized posturography device was used to assess postural stability, whereas emotional reactivity was assessed using the acoustic startle response (ASR), and neurocognitive performance was assessed using the defense-automated neurobehavioral assessment (DANA). It was hypothesized that residual and subtle postural control imbalance and deficits in cognitive and sensory reactivity would be evident in those reporting multiple lifetime mTBI. Active duty military personnel (N = 36; 7 females and 29 males) with no Deployment Limiting Medical Condition were recruited and tested on all assessments. Medical history information provided a history of head injury. Thirty-nine percent of participants reported having a previous mTBI (nine reporting one and five reporting more than one incident). No participant had experienced a head injury within the past year and all were symptom free. A significant effect of number of mTBI was found in the postural assessment (p = 0.002). Lifetime mTBI was associated with suppressed ASR magnitude (p = 0.03) but did not affect neurocognitive performance. The current findings provide new insight into ongoing controversies concerning sensitivity to functional deficits following mTBI and when the window for treatment or restoration ends.

  12. Bracing of the trunk and neck has a differential effect on head control during gait

    PubMed Central

    Russell, D. M.; Kelleran, K.; Walker, M. L.

    2015-01-01

    During gait, the trunk and neck are believed to play an important role in dissipating the transmission of forces from the ground to the head. This attenuation process is important to ensure head control is maintained. The aim of the present study was to assess the impact of externally restricting the motion of the trunk and/or neck segments on acceleration patterns of the upper body and head and related trunk muscle activity. Twelve healthy adults performed three walking trials on a flat, straight 65-m walkway, under four different bracing conditions: 1) control-no brace; 2) neck-braced; 3) trunk-braced; and 4) neck-trunk braced. Three-dimensional acceleration from the head, neck (C7) and lower trunk (L3) were collected, as was muscle activity from trunk. Results revealed that, when the neck and/or trunk were singularly braced, an overall decrease in the ability of the trunk to attenuate gait-related oscillations was observed, which led to increases in the amplitude of vertical acceleration for all segments. However, when the trunk and neck were braced together, acceleration amplitude across all segments decreased in line with increased attenuation from the neck to the head. Bracing was also reflected by increased activity in erector spinae, decreased abdominal muscle activity and lower trunk muscle coactivation. Overall, it would appear that the neuromuscular system of young, healthy individuals was able to maintain a consistent pattern of head acceleration, irrespective of the level of bracing, and that priority was placed over the control of vertical head accelerations during these gait tasks. PMID:26180113

  13. Hologram stability evaluation for Microsoft HoloLens

    NASA Astrophysics Data System (ADS)

    Vassallo, Reid; Rankin, Adam; Chen, Elvis C. S.; Peters, Terry M.

    2017-03-01

    Augmented reality (AR) has an increasing presence in the world of image-guided interventions which is amplified by the availability of consumer-grade head-mounted display (HMD) technology. The Microsoft® HoloLensTM optical passthrough device is at the forefront of consumer technology, as it is the first un-tethered head mounted computer (HMC). It shows promise of effectiveness in guiding clinical interventions, however its accuracy and stability must still be evaluated for the clinical environment. We have developed an evaluative protocol for the HoloLensTM using an optical measurement device to digitize the perceived pose of the rendered hologram. This evaluates the ability of the HoloLensTM to maintain the hologram in its intended pose. The stability is measured when actions are performed that may cause a shift in the holograms' pose due to errors in its simultaneous localization and mapping. An emphasis is placed on actions that are more likely to be performed in a clinical setting. This will be used to determine the most applicable use cases for this technology in the future and how to minimize errors when in use. Our results show promise of this device's potential for intraoperative clinical use. Further analysis must be performed to evaluate other potential sources of hologram disruption.

  14. Electrostatic Solvation Energy for Two Oppositely Charged Ions in a Solvated Protein System: Salt Bridges Can Stabilize Proteins

    PubMed Central

    Gong, Haipeng; Freed, Karl F.

    2010-01-01

    Abstract Born-type electrostatic continuum methods have been an indispensable ingredient in a variety of implicit-solvent methods that reduce computational effort by orders of magnitude compared to explicit-solvent MD simulations and thus enable treatment using larger systems and/or longer times. An analysis of the limitations and failures of the Born approaches serves as a guide for fundamental improvements without diminishing the importance of prior works. One of the major limitations of the Born theory is the lack of a liquidlike description of the response of solvent dipoles to the electrostatic field of the solute and the changes therein, a feature contained in the continuum Langevin-Debye (LD) model applied here to investigate how Coulombic interactions depend on the location of charges relative to the protein/water boundary. This physically more realistic LD model is applied to study the stability of salt bridges. When compared head to head using the same (independently measurable) physical parameters (radii, dielectric constants, etc.), the LD model is in good agreement with observations, whereas the Born model is grossly in error. Our calculations also suggest that a salt bridge on the protein's surface can be stabilizing when the charge separation is ≤4 Å. PMID:20141761

  15. Nitrited-Steel Piston Rings for Engines of High Specific Power

    NASA Technical Reports Server (NTRS)

    Collins, John H; Bisson, Edmond E; Schmiedlin, Ralph F

    1945-01-01

    Stability and control characteristics determined from tests in the Langley 19-foot pressure tunnel of a 0.2375-scale model of the Douglas XA-26 airplane are compared with those measured in flight tests of a Douglas A-26b airplane. Several designs of nitrided-steel piston rings were performance-tested under variable conditions of output. The necessity of good surface finish and conformity of the ring to the bore was indicated in the preliminary tests. Nitrided-steel rings of the same dimensions as cast-iron rings operating on the original piston were unsatisfactory, and the final design was a lighter, rectangular, thin-face-width ring used on a piston having a maximum cross-head area and a revised skirt shape. Results were obtained from single-cylinder and multicylinder engine runs.

  16. Ill-posed problem and regularization in reconstruction of radiobiological parameters from serial tumor imaging data

    NASA Astrophysics Data System (ADS)

    Chvetsov, Alevei V.; Sandison, George A.; Schwartz, Jeffrey L.; Rengan, Ramesh

    2015-11-01

    The main objective of this article is to improve the stability of reconstruction algorithms for estimation of radiobiological parameters using serial tumor imaging data acquired during radiation therapy. Serial images of tumor response to radiation therapy represent a complex summation of several exponential processes as treatment induced cell inactivation, tumor growth rates, and the rate of cell loss. Accurate assessment of treatment response would require separation of these processes because they define radiobiological determinants of treatment response and, correspondingly, tumor control probability. However, the estimation of radiobiological parameters using imaging data can be considered an inverse ill-posed problem because a sum of several exponentials would produce the Fredholm integral equation of the first kind which is ill posed. Therefore, the stability of reconstruction of radiobiological parameters presents a problem even for the simplest models of tumor response. To study stability of the parameter reconstruction problem, we used a set of serial CT imaging data for head and neck cancer and a simplest case of a two-level cell population model of tumor response. Inverse reconstruction was performed using a simulated annealing algorithm to minimize a least squared objective function. Results show that the reconstructed values of cell surviving fractions and cell doubling time exhibit significant nonphysical fluctuations if no stabilization algorithms are applied. However, after applying a stabilization algorithm based on variational regularization, the reconstruction produces statistical distributions for survival fractions and doubling time that are comparable to published in vitro data. This algorithm is an advance over our previous work where only cell surviving fractions were reconstructed. We conclude that variational regularization allows for an increase in the number of free parameters in our model which enables development of more-advanced parameter reconstruction algorithms.

  17. Effects of External Loads on Human Head Movement Control Systems

    NASA Technical Reports Server (NTRS)

    Nam, M. H.; Choi, O. M.

    1984-01-01

    The central and reflexive control strategies underlying movements were elucidated by studying the effects of external loads on human head movement control systems. Some experimental results are presented on dynamic changes weigh the addition of aviation helmet (SPH4) and lead weights (6 kg). Intended time-optimal movements, their dynamics and electromyographic activity of neck muscles in normal movements, and also in movements made with external weights applied to the head were measured. It was observed that, when the external loads were added, the subject went through complex adapting processes and the head movement trajectory and its derivatives reached steady conditions only after transient adapting period. The steady adapted state was reached after 15 to 20 seconds (i.e., 5 to 6 movements).

  18. Reirradiation of head and neck cancer: Long-term disease control and toxicity.

    PubMed

    Bots, Wouter T C; van den Bosch, Sven; Zwijnenburg, Ellen M; Dijkema, Tim; van den Broek, Guido B; Weijs, Willem L J; Verhoef, Lia C G; Kaanders, Johannes H A M

    2017-06-01

    The purpose of this study was to report long-term disease control and late radiation toxicity for patients reirradiated for head and neck cancer. We conducted a retrospective analysis of 137 patients reirradiated with a prescribed dose ≥45 Gy between 1986 and 2013 for a recurrent or second primary malignancy. Endpoints were locoregional control, overall survival (OS), and grade ≥4 late complications according to European Organization for Research and Treatment of Cancer (EORTC)/Radiation Therapy Oncology Group (RTOG) criteria. Five-year locoregional control rates were 46% for patients reirradiated postoperatively versus 20% for patients who underwent reirradiation as the primary treatment (p < .05). Sixteen cases of serious (grade ≥4) late toxicity were seen in 11 patients (actuarial 28% at 5 years). In patients reirradiated with intensity-modulated radiotherapy (IMRT), a borderline improved locoregional control was observed (49% vs 36%; p = .07), whereas late complication rates did not differ. Reirradiation should be considered for patients with a recurrent or second primary head and neck cancer, especially postoperatively, if indicated. © 2017 Wiley Periodicals, Inc. Head Neck 39: 1122-1130, 2017. © 2017 The Authors Head & Neck Published by Wiley Periodicals, Inc.

  19. Apparatus for Teaching Physics.

    ERIC Educational Resources Information Center

    Gottlieb, Herbert H., Ed.

    1978-01-01

    Describes a few apparatuses and demonstrations for teaching physics under the headings: demonstrating resonance of the inner ear, constructing a potential well-hill for overhead projectors, rubber tube vacuum pump, improvement on the simple homemade motor, air track to demonstrate sailing into the wind, and center of gravity and stability. (GA)

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelmeier, R.L.

    A technique has been described for fabrication of a radiation therapy stent that can help to stabilize the head when adjustable alignment devices are used to position a patient during radiation therapy. The technique can save time for the radiotherapist, enhance accuracy in treatment, increase patient comfort, and save the dentist time in stent fabrication.

  1. An Energy Centric Cluster-Based Routing Protocol for Wireless Sensor Networks.

    PubMed

    Hosen, A S M Sanwar; Cho, Gi Hwan

    2018-05-11

    Clustering is an effective way to prolong the lifetime of a wireless sensor network (WSN). The common approach is to elect cluster heads to take routing and controlling duty, and to periodically rotate each cluster head's role to distribute energy consumption among nodes. However, a significant amount of energy dissipates due to control messages overhead, which results in a shorter network lifetime. This paper proposes an energy-centric cluster-based routing mechanism in WSNs. To begin with, cluster heads are elected based on the higher ranks of the nodes. The rank is defined by residual energy and average distance from the member nodes. With the role of data aggregation and data forwarding, a cluster head acts as a caretaker for cluster-head election in the next round, where the ranks' information are piggybacked along with the local data sending during intra-cluster communication. This reduces the number of control messages for the cluster-head election as well as the cluster formation in detail. Simulation results show that our proposed protocol saves the energy consumption among nodes and achieves a significant improvement in the network lifetime.

  2. Entropic multi-relaxation free-energy lattice Boltzmann model for two-phase flows

    NASA Astrophysics Data System (ADS)

    Bösch, F.; Dorschner, B.; Karlin, I.

    2018-04-01

    The entropic multi-relaxation lattice Boltzmann method is extended to two-phase systems following the free-energy approach. Gain in stability is achieved by incorporating the force term due to Korteweg's stress into the redefined entropic stabilizer, which allows simulation of higher Weber and Reynolds numbers with an efficient and explicit algorithm. Results for head-on droplet collisions and droplet impact on super-hydrophobic substrates are matching experimental data accurately. Furthermore, it is demonstrated that the entropic stabilization leads to smaller spurious currents without affecting the interface thickness. The present findings demonstrate the universality of the simple and explicit entropic lattice Boltzmann models and provide a viable and robust alternative to existing methods.

  3. Modified technique for correction of isolated radial head dislocation without apparent ulnar bowing: a retrospective case study

    PubMed Central

    Tan, Lei; Li, Yan-Hui; Sun, Da-Hui; Zhu, Dong; Ning, Shu-Yan

    2015-01-01

    Objective: There is currently no general consensus on the optimal treatment of chronic radial head dislocation. Material and Methods: Considering that the annular ligament is important in maintaining elbow stability, we developed a modified method for annular ligament reconstruction in pediatric cases of radial head dislocation without ulnar bowing. We retrospectively investigated the therapeutic outcomes of this technique in a series of cases. We used our modified technique for the treatment of five patients between January 2006 and January 2012. The average age of the patients at the time of injury was 9 years (range, 6-14 years), and the patients were followed up for 1 to 3 years. Results: The perioperative and follow-up data of the patients were examined. All five surgical procedures were completed uneventfully and had been tolerated well by the patients, with minimal complications. Remarkable improvement was noted in all the cases at the end of the follow-up period. Conclusions: Our modified technique for annular ligament reconstruction was effective in achieving good reduction of the radial head dislocation with minimal complications in pediatric cases of isolated radial head dislocation without apparent ulnar bowing. PMID:26770420

  4. The oblique effect is both allocentric and egocentric

    PubMed Central

    Mikellidou, Kyriaki; Cicchini, Guido Marco; Thompson, Peter G.; Burr, David C.

    2016-01-01

    Despite continuous movements of the head, humans maintain a stable representation of the visual world, which seems to remain always upright. The mechanisms behind this stability are largely unknown. To gain some insight on how head tilt affects visual perception, we investigate whether a well-known orientation-dependent visual phenomenon, the oblique effect—superior performance for stimuli at cardinal orientations (0° and 90°) compared with oblique orientations (45°)—is anchored in egocentric or allocentric coordinates. To this aim, we measured orientation discrimination thresholds at various orientations for different head positions both in body upright and in supine positions. We report that, in the body upright position, the oblique effect remains anchored in allocentric coordinates irrespective of head position. When lying supine, gravitational effects in the plane orthogonal to gravity are discounted. Under these conditions, the oblique effect was less marked than when upright, and anchored in egocentric coordinates. The results are well explained by a simple “compulsory fusion” model in which the head-based and the gravity-based signals are combined with different weightings (30% and 70%, respectively), even when this leads to reduced sensitivity in orientation discrimination. PMID:26129862

  5. An intermittent control model of flexible human gait using a stable manifold of saddle-type unstable limit cycle dynamics

    PubMed Central

    Fu, Chunjiang; Suzuki, Yasuyuki; Kiyono, Ken; Morasso, Pietro; Nomura, Taishin

    2014-01-01

    Stability of human gait is the ability to maintain upright posture during walking against external perturbations. It is a complex process determined by a number of cross-related factors, including gait trajectory, joint impedance and neural control strategies. Here, we consider a control strategy that can achieve stable steady-state periodic gait while maintaining joint flexibility with the lowest possible joint impedance. To this end, we carried out a simulation study of a heel-toe footed biped model with hip, knee and ankle joints and a heavy head-arms-trunk element, working in the sagittal plane. For simplicity, the model assumes a periodic desired joint angle trajectory and joint torques generated by a set of feed-forward and proportional-derivative feedback controllers, whereby the joint impedance is parametrized by the feedback gains. We could show that a desired steady-state gait accompanied by the desired joint angle trajectory can be established as a stable limit cycle (LC) for the feedback controller with an appropriate set of large feedback gains. Moreover, as the feedback gains are decreased for lowering the joint stiffness, stability of the LC is lost only in a few dimensions, while leaving the remaining large number of dimensions quite stable: this means that the LC becomes saddle-type, with a low-dimensional unstable manifold and a high-dimensional stable manifold. Remarkably, the unstable manifold remains of low dimensionality even when the feedback gains are decreased far below the instability point. We then developed an intermittent neural feedback controller that is activated only for short periods of time at an optimal phase of each gait stride. We characterized the robustness of this design by showing that it can better stabilize the unstable LC with small feedback gains, leading to a flexible gait, and in particular we demonstrated that such an intermittent controller performs better if it drives the state point to the stable manifold, rather than directly to the LC. The proposed intermittent control strategy might have a high affinity for the inverted pendulum analogy of biped gait, providing a dynamic view of how the step-to-step transition from one pendular stance to the next can be achieved stably in a robust manner by a well-timed neural intervention that exploits the stable modes embedded in the unstable dynamics. PMID:25339687

  6. An intermittent control model of flexible human gait using a stable manifold of saddle-type unstable limit cycle dynamics.

    PubMed

    Fu, Chunjiang; Suzuki, Yasuyuki; Kiyono, Ken; Morasso, Pietro; Nomura, Taishin

    2014-12-06

    Stability of human gait is the ability to maintain upright posture during walking against external perturbations. It is a complex process determined by a number of cross-related factors, including gait trajectory, joint impedance and neural control strategies. Here, we consider a control strategy that can achieve stable steady-state periodic gait while maintaining joint flexibility with the lowest possible joint impedance. To this end, we carried out a simulation study of a heel-toe footed biped model with hip, knee and ankle joints and a heavy head-arms-trunk element, working in the sagittal plane. For simplicity, the model assumes a periodic desired joint angle trajectory and joint torques generated by a set of feed-forward and proportional-derivative feedback controllers, whereby the joint impedance is parametrized by the feedback gains. We could show that a desired steady-state gait accompanied by the desired joint angle trajectory can be established as a stable limit cycle (LC) for the feedback controller with an appropriate set of large feedback gains. Moreover, as the feedback gains are decreased for lowering the joint stiffness, stability of the LC is lost only in a few dimensions, while leaving the remaining large number of dimensions quite stable: this means that the LC becomes saddle-type, with a low-dimensional unstable manifold and a high-dimensional stable manifold. Remarkably, the unstable manifold remains of low dimensionality even when the feedback gains are decreased far below the instability point. We then developed an intermittent neural feedback controller that is activated only for short periods of time at an optimal phase of each gait stride. We characterized the robustness of this design by showing that it can better stabilize the unstable LC with small feedback gains, leading to a flexible gait, and in particular we demonstrated that such an intermittent controller performs better if it drives the state point to the stable manifold, rather than directly to the LC. The proposed intermittent control strategy might have a high affinity for the inverted pendulum analogy of biped gait, providing a dynamic view of how the step-to-step transition from one pendular stance to the next can be achieved stably in a robust manner by a well-timed neural intervention that exploits the stable modes embedded in the unstable dynamics.

  7. [MODEL ESTABLISHMENT, MRI AND PATHOLOGICAL FEATURES OF EARLY STEROID-INDUCED AVASCULAR NECROSIS OF FEMORAL HEAD IN RABBIT].

    PubMed

    Zhang, Liyan; Sun, Xin; Tian, Dan; Xu, Rui; Lei, Hao; Al, Jinhui; Zhao, Bo; Chen, Jiying; Chai, Wei; Ma, Shoucheng; Liu, Weijia; Shen, Siyuan

    2015-10-01

    To establish an rabbit model of early steroid-induced avascular necrosis of the femoral head (SANFH) and evaluate its validity with MRI and pathological examination. Twenty 6-month-old rabbits (weighing, 2-3 kg) were randomly divided into 2 groups (control group and model group), 10 rabbits in each group. Dexamethasone sodium phosphate solution (10 mg/kg) was injected into bilateral gluteus in model group, and the same amount of saline was injected in control group, every 3 days for 14 times. General observation was done after modelling. Osteonecrosis was verified by pathological observation and MRI findings at 6 weeks. After 6 weeks, rabbits did not show obvious changes in control group; increased hair removal, decreased food intake, and slight limp were observed in model group. The MRI results showed normal shape of the bilateral femoral head and no abnormal signals in control group; irregular shape of the bilateral femoral head and a slice of irregular abnormal signals were observed, and necrosis and cystolization of the subchondral bone and sparse changes of trabecular bone were shown in model group. General observation from coronal section of femoral head showed smooth red cartilage surface in control group; on the contrary, the cartilage surface of the femoral head became dull, thin even visible hemorrhage under articular cartilage and necrosis of the femoral head were observed. The histopathological examination indicated that trabecular bone of the femoral head in control group was massive, thick, and close and osteocytes in the bone lacunae had normal shapes. The osseous trabecular became thinner and broken; karyopyknosis of osteocytes and bone empty lacunae could be obviously seen in model. group. The rates of empty lacunae were 8.0% ± 0.5% in control group and 49.0% ± 0.3% in model group, showing significant difference (t = 21.940, P = 0.000). Establishing a model of early SANFH through injecting short-term, shock, and high dose of dexamethasone, and it can been evaluated effectively with MRI and pathological examination.

  8. Nonspherical femoral head shape (pistol grip deformity), neck shaft angle, and risk of hip osteoarthritis: a case-control study.

    PubMed

    Doherty, Michael; Courtney, Philip; Doherty, Sally; Jenkins, Wendy; Maciewicz, Rose A; Muir, Kenneth; Zhang, Weiya

    2008-10-01

    To determine whether 2-dimensional measures of femoral head shape and angle are associated with hip osteoarthritis (OA). We compared cases with symptomatic radiographic hip OA with asymptomatic controls with no radiographic hip OA. On anteroposterior pelvis radiographs, we measured "pistol grip deformity" for each hip (visually categorized as nonspherical, indeterminate, or spherical), the femoral head-to-femoral neck ratio as an interval measure of femoral head shape, and the femoral neck shaft angle. The relative risk of hip OA associated with each feature was estimated using odds ratios (ORs) and 95% confidence intervals (95% CIs), adjusted for possible confounders using a logistic regression model. Of 1,007 cases, 965 had definite radiographic hip OA; of 1,123 controls, 1,111 had no radiographic OA. The prevalence of pistol grip deformity in at least 1 hip was 3.61% in controls and 17.71% in cases (OR 6.95 [95% CI 4.64-10.41]), and the prevalence of abnormal femoral head-to-femoral neck ratio in at least 1 hip was 3.70% in controls and 24.27% in cases (OR 12.08 [95% CI 8.05-18.15]). The risk of hip OA increased as the femoral head-to-femoral neck ratio decreased (P for trend<0.001) and with each extreme of neck shaft angle (P<0.05). In cases with unilateral hip OA, the prevalence of abnormal femoral head-to-femoral neck ratio in the unaffected hip was 2 times greater than that in controls (OR 1.82 [95% CI 1.07-3.07]); in contrast, an abnormally low, but not abnormally high, neck shaft angle was more common in unaffected hips than in controls (OR 1.79 [95% CI 1.03-3.14]). Our findings indicate that pistol grip deformity is associated with hip OA. The increased prevalence of pistol grip deformity and an abnormally low neck shaft angle in unaffected hips of cases with unilateral OA suggests that they are risk factors for development of hip OA. However, both a nonspherical head shape and an increase in neck shaft angle may occur as a consequence of OA.

  9. Evaluation of tooth-click triggering and speech recognition in assistive technology for computer access.

    PubMed

    Simpson, Tyler; Gauthier, Michel; Prochazka, Arthur

    2010-02-01

    Computer access can play an important role in employment and leisure activities following spinal cord injury. The authors' prior work has shown that a tooth-click detecting device, when paired with an optical head mouse, may be used by people with tetraplegia for controlling cursor movement and mouse button clicks. To compare the efficacy of tooth clicks to speech recognition and that of an optical head mouse to a gyrometer head mouse for cursor and mouse button control of a computer. Six able-bodied and 3 tetraplegic subjects used the devices listed above to produce cursor movements and mouse clicks in response to a series of prompts displayed on a computer. The time taken to move to and click on each target was recorded. The use of tooth clicks in combination with either an optical head mouse or a gyrometer head mouse can provide hands-free cursor movement and mouse button control at a speed of up to 22% of that of a standard mouse. Tooth clicks were significantly faster at generating mouse button clicks than speech recognition when paired with either type of head mouse device. Tooth-click detection performed better than speech recognition when paired with both the optical head mouse and the gyrometer head mouse. Such a system may improve computer access for people with tetraplegia.

  10. Head Start: An Effective Program But the Fund Distribution Formula Needs Revision and Management Controls Need Improvement. Report to the Congress of the United States by the Comptroller General.

    ERIC Educational Resources Information Center

    Comptroller General of the U.S., Washington, DC.

    This report from the Comptroller General to the United States Congress finds Head Start to be an effective program whose fund distribution formula needs revision and whose management controls need improvement. Head Start's funding for enrollment and operating costs increased significantly between 1977-81. However, these funding increases were not…

  11. Adaptive Control of Small Outboard-Powered Boats for Survey Applications

    NASA Technical Reports Server (NTRS)

    VanZwieten, T.S.; VanZwieten, J.H.; Fisher, A.D.

    2009-01-01

    Four autopilot controllers have been developed in this work that can both hold a desired heading and follow a straight line. These PID, adaptive PID, neuro-adaptive, and adaptive augmenting control algorithms have all been implemented into a numerical simulation of a 33-foot center console vessel with wind, waves, and current disturbances acting in the perpendicular (across-track) direction of the boat s desired trajectory. Each controller is tested for its ability to follow a desired heading in the presence of these disturbances and then to follow a straight line at two different throttle settings for the same disturbances. These controllers were tuned for an input thrust of 2000 N and all four controllers showed good performance with none of the controllers significantly outperforming the others when holding a constant heading and following a straight line at this engine thrust. Each controller was then tested for a reduced engine thrust of 1200 N per engine where each of the three adaptive controllers reduced heading error and across-track error by approximately 50% after a 300 second tuning period when compared to the fixed gain PID, showing that significant robustness to changes in throttle setting was gained by using an adaptive algorithm.

  12. Test-retest reliability and responsiveness of gaze stability and dynamic visual acuity in high school and college football players.

    PubMed

    Kaufman, Denise R; Puckett, Mallory J; Smith, Mitchell J; Wilson, Kyle S; Cheema, Rebecca; Landers, Merrill R

    2014-08-01

    The purpose of this study was to establish reliability and responsiveness of the dynamic visual acuity test (DVAT) at head speeds of 150-200 degrees per second (deg/s) and the gaze stabilization test (GST) in high school and college football players. Reliability design. Fifty high school and college football athletes completed the DVAT and GST in both the yaw (horizontal) and pitch (vertical) planes twice within two weeks. Test-retest reliability for the DVAT was good in yaw, Intraclass Correlation Coefficient (ICC) = 0.770, and moderate/good in pitch, ICC = 0.725. Minimal detectable change (MDC) was 0.16 logMAR for yaw and 0.21 logMAR for pitch. GST reliability was moderate in yaw, ICC = 0.634, and poor in pitch, ICC = 0.411. MDCs were 73.4 deg/s (yaw) and 81.2 deg/s (pitch). The DVAT is reliable at high head speeds in high school and college football athletes in both yaw and pitch. GST head speeds were higher than previously reported in the literature, but reliability of this tool for this population was poor to moderate. From a clinical perspective, DVAT may be reliably used in the assessment of high school and college football athletes; however, GST requires further evaluation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Phosphorylation of cardiac myosin binding protein C releases myosin heads from the surface of cardiac thick filaments

    PubMed Central

    Kensler, Robert W.; Craig, Roger; Moss, Richard L.

    2017-01-01

    Cardiac myosin binding protein C (cMyBP-C) has a key regulatory role in cardiac contraction, but the mechanism by which changes in phosphorylation of cMyBP-C accelerate cross-bridge kinetics remains unknown. In this study, we isolated thick filaments from the hearts of mice in which the three serine residues (Ser273, Ser282, and Ser302) that are phosphorylated by protein kinase A in the m-domain of cMyBP-C were replaced by either alanine or aspartic acid, mimicking the fully nonphosphorylated and the fully phosphorylated state of cMyBP-C, respectively. We found that thick filaments from the cMyBP-C phospho-deficient hearts had highly ordered cross-bridge arrays, whereas the filaments from the cMyBP-C phospho-mimetic hearts showed a strong tendency toward disorder. Our results support the hypothesis that dephosphorylation of cMyBP-C promotes or stabilizes the relaxed/superrelaxed quasi-helical ordering of the myosin heads on the filament surface, whereas phosphorylation weakens this stabilization and binding of the heads to the backbone. Such structural changes would modulate the probability of myosin binding to actin and could help explain the acceleration of cross-bridge interactions with actin when cMyBP-C is phosphorylated because of, for example, activation of β1-adrenergic receptors in myocardium. PMID:28167762

  14. Phosphorylation of cardiac myosin binding protein C releases myosin heads from the surface of cardiac thick filaments.

    PubMed

    Kensler, Robert W; Craig, Roger; Moss, Richard L

    2017-02-21

    Cardiac myosin binding protein C (cMyBP-C) has a key regulatory role in cardiac contraction, but the mechanism by which changes in phosphorylation of cMyBP-C accelerate cross-bridge kinetics remains unknown. In this study, we isolated thick filaments from the hearts of mice in which the three serine residues (Ser273, Ser282, and Ser302) that are phosphorylated by protein kinase A in the m-domain of cMyBP-C were replaced by either alanine or aspartic acid, mimicking the fully nonphosphorylated and the fully phosphorylated state of cMyBP-C, respectively. We found that thick filaments from the cMyBP-C phospho-deficient hearts had highly ordered cross-bridge arrays, whereas the filaments from the cMyBP-C phospho-mimetic hearts showed a strong tendency toward disorder. Our results support the hypothesis that dephosphorylation of cMyBP-C promotes or stabilizes the relaxed/superrelaxed quasi-helical ordering of the myosin heads on the filament surface, whereas phosphorylation weakens this stabilization and binding of the heads to the backbone. Such structural changes would modulate the probability of myosin binding to actin and could help explain the acceleration of cross-bridge interactions with actin when cMyBP-C is phosphorylated because of, for example, activation of β 1 -adrenergic receptors in myocardium.

  15. Core Stability Exercise Versus General Exercise for Chronic Low Back Pain.

    PubMed

    Coulombe, Brian J; Games, Kenneth E; Neil, Elizabeth R; Eberman, Lindsey E

    2017-01-01

    Reference: Wang XQ, Zheng JJ, Yu ZW, et al. A meta-analysis of core stability exercise versus general exercise for chronic low back pain. PLoS One. 2012;7(12):e52082. Clinical Questions: Is core stability exercise more effective than general exercise in the treatment of patients with nonspecific low back pain (LBP)?  The authors searched the following databases: China Biological Medicine disc, Cochrane Library, Embase, and PubMed from 1970 through 2011. The key medical subject headings searched were chronic pain, exercise, LBP, lumbosacral region, and sciatica.  Randomized controlled trials comparing core stability exercise with general exercise in the treatment of chronic LBP were investigated. Participants were male and female adults with LBP for at least 3 months that was not caused by a specific known condition. A control group receiving general exercise and an experimental group receiving core stability exercise were required for inclusion in the meta-analysis. Core stability was defined as the ability to ensure a stable neutral spine position, but the type of exercise was not specified. Outcome measures of pain intensity, back-specific functional status, quality of life, and work absenteeism were recorded at 3-, 6-, and 12-month intervals.  The study design, participant information, description of interventions in the control and experimental groups, outcome measures, and follow-up period were extracted. The mean difference (MD) and 95% confidence interval (CI) were calculated to evaluate statistical significance. Risk of bias was assessed using the Cochrane Collaboration Recommendations, and all articles were rated as high risk for other bias with no further explanation given.  Five studies involving 414 patients were included. Four studies assessed pain intensity using the visual analog scale or numeric rating scale. In the core stability exercise group, the reduction in pain was significant at 3 months (MD = -1.29, 95% CI = -2.47, -0.11; P = .003) but not at 6 months (MD = -0.50, 95% CI = -1.36, 0.35; P = .26). Functional status was improved at 3 months (MD = -7.14, 95% CI = -11.64, -2.65; P = .002) but not at 6 months (MD = -0.50, 95% CI = 0.36, 0.35; P = .26) or 12 months (MD = -0.32, 95% CI = -0.87, 0.23; P = .25). All of the included studies assessed back-specific functional status: 4 used the Oswestry Disability Index and 1 used the Roland-Morris Disability Questionnaire. Patients in the core stability exercise groups experienced improved functional status versus the general exercise group at 3 months (MD = -7.14, 95% CI = -11.64, -2.65; P = .002); no results were recorded at 6 or 12 months.  In the short term, core stability exercise was more effective than general exercise for decreasing pain and increasing back-specific functional status in patients with LBP.

  16. Spectroscopic Studies of the Super Relaxed State of Skeletal Muscle

    PubMed Central

    Naber, Nariman; Pate, Edward; Canton, Marcella; Reggiani, Carlo; Cooke, Roger

    2016-01-01

    In the super-relaxed state of myosin, ATPase activity is strongly inhibited by binding of the myosin heads to the core of the thick filament in a structure known as the interacting-heads motif. In the disordered relaxed state myosin heads are not bound to the core of the thick filament and have an ATPase rate that is 10 fold greater. In the interacting-heads motif the two regulatory light chains appear to bind to each other. We have made single cysteine mutants of the regulatory light chain, placed both paramagnetic and fluorescent probes on them, and exchanged them into skinned skeletal muscle fibers. Many of the labeled light chains tended to disrupt the stability of the super-relaxed state, and showed spectral changes in the transition from the disordered relaxed state to the super-relaxed state. These data support the putative interface between the two regulatory light chains identified by cryo electron microscopy and show that both the divalent cation bound to the regulatory light chain and the N-terminus of the regulatory light chain play a role in the stability of the super-relaxed state. One probe showed a shift to shorter wavelengths in the super-relaxed state such that a ratio of intensities at 440nm to that at 520nm provided a measure of the population of the super-relaxed state amenable for high throughput screens for finding potential pharmaceuticals. The results provide a proof of concept that small molecules that bind to this region can destabilize the super-relaxed state and provide a method to search for small molecules that do so leading to a potentially effective treatment for Type 2 diabetes and obesity. PMID:27479128

  17. 77 FR 8878 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-15

    .... Participants have been randomly assigned to either a Head Start group or a control group. Data collection for... of 4,667 treatment and control group members in the Head Start Impact Study, minus 432 families that...

  18. International Federation of Head Neck Oncology Society 5(th) World Congress/American Head Neck Society 2014 update.

    PubMed

    Sharma, Shilpi; Chaukar, Devendra A

    2014-07-01

    Head neck cancer is an important health problem with high morbidity and mortality. Early detection and adequate treatment improve prognosis significantly. Thus creating awareness among clinicians is an important step toward control of head neck cancer and reducing its overall burden. We here provide an update on the International Federation of Head Neck Oncology Society/American Head Neck Society 2014 held between July 26, 2014 and July 30, 2014 in New York.

  19. Head Rotation Movement Times.

    PubMed

    Hoffmann, Errol R; Chan, Alan H S; Heung, P T

    2017-09-01

    The aim of this study was to measure head rotation movement times in a Fitts' paradigm and to investigate the transition region from ballistic movements to visually controlled movements as the task index of difficulty (ID) increases. For head rotation, there are gaps in the knowledge of the effects of movement amplitude and task difficulty around the critical transition region from ballistic movements to visually controlled movements. Under the conditions of 11 ID values (from 1.0 to 6.0) and five movement amplitudes (20° to 60°), participants performed a head rotation task, and movement times were measured. Both the movement amplitude and task difficulty have effects on movement times at low IDs, but movement times are dependent only on ID at higher ID values. Movement times of participants are higher than for arm/hand movements, for both ballistic and visually controlled movements. The information-processing rate of head rotational movements, at high ID values, is about half that of arm movements. As an input mode, head rotations are not as efficient as the arm system either in ability to use rapid ballistic movements or in the rate at which information may be processed. The data of this study add to those in the review of Hoffmann for the critical IDs of different body motions. The data also allow design for the best arrangement of display that is under the design constraints of limited display area and difficulty of head-controlled movements in a data-inputting task.

  20. Correlates of head circumference growth in infants later diagnosed with autism spectrum disorders.

    PubMed

    Mraz, Krista D; Green, James; Dumont-Mathieu, Thyde; Makin, Sarah; Fein, Deborah

    2007-06-01

    Previous research has demonstrated that children diagnosed with autism spectrum disorder show an abnormal acceleration of head growth during the first year of life. This study attempts to replicate these findings and to determine whether overgrowth is associated with clinical outcome. Measurements of head circumference, body length, and body weight taken during the first 2 years of life were obtained from a sample of 35 children diagnosed with autism spectrum disorder and compared to both national normative data (Centers for Disease Control and Prevention) and a control group of 37 healthy infants. Results demonstrated that compared to national averages, infants who were later diagnosed with autism spectrum disorder had a significantly smaller head circumference at birth to 2 weeks and a significantly larger head circumference by 10 to 14 months. Children with autism spectrum disorder were also significantly longer and heavier beginning at 1 to 2 months. However, when overall length and weight were controlled, head circumference was not bigger in the autistic spectrum disorder group compared to local controls. Correlations between head circumference and clinical outcome were significant for 5 of the 30 clinical variables that were run, suggesting that there appears to be no simple or straightforward relationship between head circumference and clinical outcome. Smaller head circumference at birth to 2 weeks was associated with a greater number of symptoms related to social impairment and a greater total number of autism spectrum disorder symptoms based on the Diagnostic and Statistical Manual of Mental Disorders , Fourth Edition criteria. Larger head circumference at 15 to 25 months was also associated with a greater number of symptoms of social impairment. In addition, greater head circumference change during the first 2 years was associated with poorer performance on the visual reception subtest of the Mullen Scales of Early Learning and a smaller number of stereotyped and repetitive behaviors and interests based on the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria. These findings support previous findings of accelerated brain growth during the first year of life in autism spectrum disorder and question whether growth factors might contribute to both accelerated brain growth and overall body growth.

  1. Matching the oculomotor drive during head-restrained and head-unrestrained gaze shifts in monkey.

    PubMed

    Bechara, Bernard P; Gandhi, Neeraj J

    2010-08-01

    High-frequency burst neurons in the pons provide the eye velocity command (equivalently, the primary oculomotor drive) to the abducens nucleus for generation of the horizontal component of both head-restrained (HR) and head-unrestrained (HU) gaze shifts. We sought to characterize how gaze and its eye-in-head component differ when an "identical" oculomotor drive is used to produce HR and HU movements. To address this objective, the activities of pontine burst neurons were recorded during horizontal HR and HU gaze shifts. The burst profile recorded on each HU trial was compared with the burst waveform of every HR trial obtained for the same neuron. The oculomotor drive was assumed to be comparable for the pair yielding the lowest root-mean-squared error. For matched pairs of HR and HU trials, the peak eye-in-head velocity was substantially smaller in the HU condition, and the reduction was usually greater than the peak head velocity of the HU trial. A time-varying attenuation index, defined as the difference in HR and HU eye velocity waveforms divided by head velocity [alpha = (H(hr) - E(hu))/H] was computed. The index was variable at the onset of the gaze shift, but it settled at values several times greater than 1. The index then decreased gradually during the movement and stabilized at 1 around the end of gaze shift. These results imply that substantial attenuation in eye velocity occurs, at least partially, downstream of the burst neurons. We speculate on the potential roles of burst-tonic neurons in the neural integrator and various cell types in the vestibular nuclei in mediating the attenuation in eye velocity in the presence of head movements.

  2. Intact vinculin protein is required for control of cell shape, cell mechanics, and rac-dependent lamellipodia formation

    NASA Technical Reports Server (NTRS)

    Goldmann, Wolfgang H.; Ingber, Donald E.

    2002-01-01

    Studies were carried out using vinculin-deficient F9 embryonic carcinoma (gamma229) cells to analyze the relationship between structure and function within the focal adhesion protein vinculin, in the context of control of cell shape, cell mechanics, and movement. Atomic force microscopy studies revealed that transfection of the head (aa 1-821) or tail (aa 811-1066) domain of vinculin, alone or together, was unable to fully reverse the decrease in cell stiffness, spreading, and lamellipodia formation caused by vinculin deficiency. In contrast, replacement with intact vinculin completely restored normal cell mechanics and spreading regardless of whether its tyrosine phosphorylation site was deleted. Constitutively active rac also only induced extension of lamellipodia when microinjected into cells that expressed intact vinculin protein. These data indicate that vinculin's ability to physically couple integrins to the cytoskeleton, to mechanically stabilize cell shape, and to support rac-dependent lamellipodia formation all appear to depend on its intact three-dimensional structure.

  3. Multisensory control of a straight locomotor trajectory.

    PubMed

    Hanna, Maxim; Fung, Joyce; Lamontagne, Anouk

    2017-01-01

    Locomotor steering is contingent upon orienting oneself spatially in the environment. When the head is turned while walking, the optic flow projected onto the retina is a complex pattern comprising of a translational and a rotational component. We have created a unique paradigm to simulate different optic flows in a virtual environment. We hypothesized that non-visual (vestibular and somatosensory) cues are required for proper control of a straight trajectory while walking. This research study included 9 healthy young subjects walking in a large physical space (40×25m2) while the virtual environment is viewed in a helmet-mounted display. They were instructed to walk straight in the physical world while being exposed to three conditions: (1) self-initiated active head turns (AHT: 40° right, left, or none); (2) visually simulated head turns (SHT); and (3) visually simulated head turns with no target element (SHT_NT). Conditions 1 and 2 involved an eye-level target which subjects were instructed to fixate, whereas condition 3 was similar to condition 2 but with no target. Identical retinal flow patterns were present in the AHT and SHT conditions whereas non-visual cues differed in that a head rotation was sensed only in AHT but not in SHT. Body motions were captured by a 12-camera Vicon system. Horizontal orientations of the head and body segments, as well as the trajectory of the body's centre of mass were analyzed. SHT and SNT_NT yielded similar results. Heading and body segment orientations changed in the direction opposite to the head turns in SHT conditions. Heading remained unchanged across head turn directions in AHT. Results suggest that non-visual information is used in the control of heading while being exposed to changing rotational optic flows. The small magnitude of the changes in SHT conditions suggests that the CNS can re-weight relevant sources of information to minimize heading errors in the presence of sensory conflicts.

  4. Biocontrol of Listeria monocytogenes and Escherichia coli O157:H7 in Meat by Using Phages Immobilized on Modified Cellulose Membranes ▿

    PubMed Central

    Anany, H.; Chen, W.; Pelton, R.; Griffiths, M. W.

    2011-01-01

    The ability of phages to specifically interact with and lyse their host bacteria makes them ideal antibacterial agents. The range of applications of bacteriophage can be extended by their immobilization on inert surfaces. A novel method for the oriented immobilization of bacteriophage has been developed. The method was based on charge differences between the bacteriophage head, which exhibits an overall net negative charge, and the tail fibers, which possess an overall net positive charge. Hence, the head would be more likely to attach to positively charged surfaces, leaving the tails free to capture and lyse bacteria. Cellulose membranes modified so that they had a positive surface charge were used as the support for phage immobilization. It was established that the number of infective phages immobilized on the positively charged cellulose membranes was significantly higher than that on unmodified membranes. Cocktails of phages active against Listeria or Escherichia coli immobilized on these membranes were shown to effectively control the growth of L. monocytogenes and E. coli O157:H7 in ready-to-eat and raw meat, respectively, under different storage temperatures and packaging conditions. The phage storage stability was investigated to further extend their industrial applications. It was shown that lyophilization can be used as a phage-drying method to maintain their infectivity on the newly developed bioactive materials. In conclusion, utilizing the charge difference between phage heads and tails provided a simple technique for oriented immobilization applicable to a wide range of phages and allowed the retention of infectivity. PMID:21803890

  5. A compact, efficient, and lightweight laser head for CARLO®: integration, performance, and benefits

    NASA Astrophysics Data System (ADS)

    Deibel, Waldemar; Schneider, Adrian; Augello, Marcello; Bruno, Alfredo E.; Juergens, Philipp; Cattin, Philippe

    2015-09-01

    Ever since the first functional lasers were built about 50 years ago, researchers and doctors dream of a medical use for such systems. Today's technology is finally advanced enough to realize these ambitions in a variety of medical fields. There are well-established laser based systems in ophthalmology, dental applications, treatment of kidney stones, and many more. Using lasers presents more than just an alternative to conventional methods for osteotomies. It offers less tissue damage, faster healing times, comparable intervention duration and in consequence improves postoperative treatment of patients. However, there are a few factors that limit routine applications. These technical drawbacks include missing depth control and safe guiding of the laser beam. This paper presents the engineering and integration of a miniaturized laser head for a computer assisted and robot-guided laser osteotome (CARLO®), which can overcome the mentioned drawbacks. The CARLO® device ensures a safe and precise guidance of the laser beam. Such guidance also enables new opportunities and methods, e.g. free geometrical functional cuts, which have the potential to revolutionize bone surgery. The laser head is optimized for beam shaping, target conditioning, working distance, compactness and the integration of all other parts needed, e.g. CCD-cameras for monitoring and referencing, a visible laser for cut simulation, etc. The beam coming out of the laser system is conditioned in shape, energy properties and working distance with an optical arrangement to achieve the desired cutting performance. Here also parameters like optical losses, operating mode, optics materials and long-term stability have are taken into account.

  6. SUSTAINABLE WATER EXTRACTION AND DISTRIBUTION SYSTEM FOR AGRICULTURAL APPLICATIONS IN NAMAWANGA, KENYA

    EPA Science Inventory

    In order to ensure that the pumps are successful when installed for the community, working prototypes were tested, analyzed, and modified. The chief concerns of our functional analysis were the flow rate of the pump, the stability/durability of the system, total pumping head, ...

  7. NASA's Functional Task Test: Effects of Spaceflight and Six Degree Head-Down Bedrest on Dynamic Postural Stability

    NASA Technical Reports Server (NTRS)

    Taylor, L. C.; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2015-01-01

    The goals of the Functional Task Test (FTT) study were to determine the effects of spaceflight on functional tests that are representative of critical exploration mission tasks and to identify the physiological factors that contribute to decrements in performance.

  8. Verbal Ability and Executive Functioning Development in Preschoolers at Head Start

    ERIC Educational Resources Information Center

    Fuhs, Mary Wagner; Day, Jeanne D.

    2011-01-01

    Research suggests that executive functioning skills may enhance the school readiness of children from disadvantaged homes. Questions remain, however, concerning both the structure and the stability of executive functioning among preschoolers. In addition, there is a lack of research addressing potential predictors of longitudinal change in…

  9. Autism spectrum disorders: head circumference and body length at birth are both relative.

    PubMed

    Grandgeorge, Marine; Lemonnier, Eric; Jallot, Nelle

    2013-09-01

    Although the body length and weight of an infant are related to head circumference, little research on ASDs has examined these factors. Our study compared the head circumferences of neonates who were later diagnosed with ASD with a control group. Additional comparisons on morphological disproportions at birth included the head circumference-to-height and head circumference-to-weight ratios. We recruited 422 children with ASD and 153 typically developing children. Head circumference, body length and weight at birth were collected and standardized as percentile scores according to gestational age and gender. Our results revealed that genuine macrocephaly was significantly higher in children with other pervasive developmental disorders compared with the control group. This difference was not observed with regard to genuine microcephaly. Relative macrocephaly and relative microcephaly were significantly more frequent in children with autism disorder compared with the control group with regard to body length. The differences in relative macrocephaly and microcephaly, as well as in other parameters, between diagnostic subgroups suggest that the presence of several neurological mechanisms plays a role in the later expression of different phenotypes. An increased head circumference-to-body length ratio in newborns may be a factor to follow that could be related to ASD. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  10. A pilot study of the use of oral ivermectin to treat head lice in primary school students in Australia.

    PubMed

    Currie, Marian J; Reynolds, Graham J; Glasgow, Nicholas J; Bowden, Francis J

    2010-01-01

    Head lice are a common, costly public health problem worldwide. We aimed to determine the feasibility of an ivermectin intervention program. Consenting students in two schools were screened for head lice. Infested students and siblings at one school were offered a head lice fact sheet and two doses of oral ivermectin, 7 days apart. Parents of infested students in the other school were given the same fact sheet and asked to treat the child and siblings using their preferred topical treatment. Seven hundred two of 754 (93.1%) students enrolled in the two schools were screened; 40 (5.3%; 95% CI 3.7-6.9) had head lice; 31 (9.4%; 95% CI 6.1-12.2) in the intervention school and nine (2.5%; 95% CI 1.1-3.8) in the control school. Subsequently 93.6% of children in the intervention school were treated with oral ivermectin. No adverse events were reported. At 6 months the reduction in the head lice infestation rates for the intervention and control schools were 87% and 56%, respectively. This pilot study suggests that school wide screening for head lice and the administration of oral ivermectin is feasible and acceptable. A randomized controlled trial at 20 schools is planned. © 2010 Wiley Periodicals, Inc.

  11. Reference gene stability of a synanthropic fly, Chrysomya megacephala.

    PubMed

    Wang, Xiaoyun; Xiong, Mei; Wang, Jialu; Lei, Chaoliang; Zhu, Fen

    2015-10-29

    Stable reference genes are essential for accurate normalization in gene expression studies with reverse transcription quantitative polymerase chain reaction (qPCR). A synanthropic fly, Chrysomya megacephala, is a well known medical vector and forensic indicator. Unfortunately, previous studies did not look at the stability of reference genes used in C. megacephala. In this study, the expression level of Actin, ribosomal protein L8 (Rpl8), glyceraldehyde-3-phosphate dehydrogenase (GAPDH), elongation factor 1α (EF1), α-tubulin (α-TUB), β-tubulin (β-TUB), TATA binding box (TBP), 18S rRNA (18S) and ribosomal protein S7 (Rps7) were evaluated for their stability using online software RefFinder, which combines the normal software of the ΔCt method, BestKeeper, Normfinder, and geNorm. Moreover the number of suitable reference gene pairs was also suggested by Excel-based geNorm. The expression levels of these reference genes were evaluated under different experimental conditions with special perspectives of forensic applications: developmental stages (eggs, first, second and third instar larvae, pupae and adults); food sources of larvae (pork, fish and chicken); feeding larvae with drugs (untreated control, Estazolam and Marvelon); feeding larvae with heavy metals (untreated control, cadmium and zinc); tissues of adults (head, thorax, abdomen, legs and wings). According to RefFinder, EF1 was the most suitable reference gene of developmental stages, food and tissues; 18S and GAPDH were the most suitable reference genes for drugs and heavy metals, respectively, which could be widely used for quantification of target gene expression with qPCR in C. megacephala. Suitable reference gene pairs were also suggested by geNorm. This fundamental but vital work should facilitate the gene studies of related biological processes and deepen the understanding in physiology, toxicology, and especially medical and forensic entomology of C. megacephala.

  12. Interaction of the body, head, and eyes during walking and turning

    NASA Technical Reports Server (NTRS)

    Imai, T.; Moore, S. T.; Raphan, T.; Cohen, B.

    2001-01-01

    Body, head, and eye movements were measured in five subjects during straight walking and while turning corners. The purpose was to determine how well the head and eyes followed the linear trajectory of the body in space and whether head orientation followed changes in the gravito-inertial acceleration vector (GIA). Head and body movements were measured with a video-based motion analysis system and horizontal, vertical, and torsional eye movements with video-oculography. During straight walking, there was lateral body motion at the stride frequency, which was at half the frequency of stepping. The GIA oscillated about the direction of heading, according to the acceleration and deceleration associated with heel strike and toe flexion, and the body yawed in concert with stepping. Despite the linear and rotatory motions of the head and body, the head pointed along the forward motion of the body during straight walking. The head pitch/roll component appeared to compensate for vertical and horizontal acceleration of the head rather than orienting to the tilt of the GIA or anticipating it. When turning corners, subjects walked on a 50-cm radius over two steps or on a 200-cm radius in five to seven steps. Maximum centripetal accelerations in sharp turns were ca.0.4 g, which tilted the GIA ca.21 degrees with regard to the heading. This was anticipated by a roll tilt of the head of up to 8 degrees. The eyes rolled 1-1.5 degrees and moved down into the direction of linear acceleration during the tilts of the GIA. Yaw head deviations moved smoothly through the turn, anticipating the shift in lateral body trajectory by as much as 25 degrees. The trunk did not anticipate the change in trajectory. Thus, in contrast to straight walking, the tilt axes of the head and the GIA tended to align during turns. Gaze was stable in space during the slow phases and jumped forward in saccades along the trajectory, leading it by larger angles when the angular velocity of turning was greater. The anticipatory roll head movements during turning are likely to be utilized to overcome inertial forces that would destabilize balance during turning. The data show that compensatory eye, head, and body movements stabilize gaze during straight walking, while orienting mechanisms direct the eyes, head, and body to tilts of the GIA in space during turning.

  13. Chin plate with a detachable C-tube head serves for both osteotomy fixation and orthodontic anchorage.

    PubMed

    Seo, Kyung-Won; Nahm, Kyung-Yen; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2013-07-01

    This article reports the dual function of a double-Y miniplate with a detachable C-tube head (C-chin plate; Jin Biomed Co., Bucheon, Korea) used to fixate an anterior segmental osteotomy and provide skeletal anchorage during orthodontic tooth movement. Cases were selected for this study from patients who underwent anterior segmental osteotomy under local anesthesia. A detachable C-tube head portion was combined with a double-Y chin plate. The double-Y chin plates were fixated between the osteotomy segments and the mandibular base with screws in a conventional way. The C-tube head portion exited the tissue near the mucogingival junction. Biocreative Chin Plates were placed on the anterior segmental osteotomy sites. The device allowed 3 points of fixation: 1, minor postosteotomy vertical adjustment of the segment during healing; 2, minor shift of the midline during healing; and 3, to serve as temporary skeletal anchorage device during the post-anterior segmental osteotomy orthodontic treatment. When tooth movement goals are accomplished, the C-tube head of the chin plate can be easily detached from the fixation miniplate by twisting the head using a Weingart plier under local anesthesia. This dual-purpose device spares the patient from the need for 2 separate installations for stabilization of osteotomy segments. The dual-purpose double-Y miniplate combined with a C-tube head (Biocreative Chin Plate) provided versatile application of 3 points of post-osteotomy fixation and of temporary skeletal anchorage for orthodontic tooth movement.

  14. Post-operative infection with fresh frozen allograft: reported outcomes of a hospital-based bone bank over 14 years.

    PubMed

    Man, Wing Yum; Monni, Toni; Jenkins, Ruth; Roberts, Paul

    2016-06-01

    Femoral head bone allografts have traditionally been used to provide mechanical stability to areas of bony deficiency, or for its osteoinductive and osteoconductive properties. Concerns have been raised over increased infection rates following the use of fresh-frozen graft tissue. This retrospective study aims to investigate the outcomes of fresh frozen femoral heads kept in a regulated, non-commercial bone bank at a university teaching hospital.The local bone bank database was used to identify released femoral heads during a 14 year study period (September 1999-December 2013) whereby a retrospective review of patient records was undertaken to determine clinical outcome. During the observed study period, 427 femoral heads were released from cold storage. Of these, 270 femoral heads had a mean follow-up of 347 days. 157 femoral heads were excluded due to insufficient follow-up data (n = 132) or discarded due to breaks in the cold chain prior to use (n = 25). Of the 270 included femoral heads, 231 (85.6 %) had no reported complications with good graft incorporation. In the remaining 39 with reported complications, only 5 (2.6 %) developed a postoperative infection. Our findings suggest that the use of fresh frozen allograft does not materially increase the risk of post-operative bacterial infection. Our reported post-operative infection rates are comparable with infection rates of other similar studies on fresh frozen allograft use.

  15. Experimental Test of Spatial Updating Models for Monkey Eye-Head Gaze Shifts

    PubMed Central

    Van Grootel, Tom J.; Van der Willigen, Robert F.; Van Opstal, A. John

    2012-01-01

    How the brain maintains an accurate and stable representation of visual target locations despite the occurrence of saccadic gaze shifts is a classical problem in oculomotor research. Here we test and dissociate the predictions of different conceptual models for head-unrestrained gaze-localization behavior of macaque monkeys. We adopted the double-step paradigm with rapid eye-head gaze shifts to measure localization accuracy in response to flashed visual stimuli in darkness. We presented the second target flash either before (static), or during (dynamic) the first gaze displacement. In the dynamic case the brief visual flash induced a small retinal streak of up to about 20 deg at an unpredictable moment and retinal location during the eye-head gaze shift, which provides serious challenges for the gaze-control system. However, for both stimulus conditions, monkeys localized the flashed targets with accurate gaze shifts, which rules out several models of visuomotor control. First, these findings exclude the possibility that gaze-shift programming relies on retinal inputs only. Instead, they support the notion that accurate eye-head motor feedback updates the gaze-saccade coordinates. Second, in dynamic trials the visuomotor system cannot rely on the coordinates of the planned first eye-head saccade either, which rules out remapping on the basis of a predictive corollary gaze-displacement signal. Finally, because gaze-related head movements were also goal-directed, requiring continuous access to eye-in-head position, we propose that our results best support a dynamic feedback scheme for spatial updating in which visuomotor control incorporates accurate signals about instantaneous eye- and head positions rather than relative eye- and head displacements. PMID:23118883

  16. Control over the processing of the opponent's gaze direction in basketball experts.

    PubMed

    Weigelt, Matthias; Güldenpenning, Iris; Steggemann-Weinrich, Yvonne; Alhaj Ahmad Alaboud, Mustafa; Kunde, Wilfried

    2017-06-01

    Basketball players' responses to an opposing players' pass direction are typically delayed when the opposing player gazes in another than the pass direction. Here, we studied the role of basketball expertise on this, the so-called head-fake effect, in three groups of participants (basketball experts, soccer players, and non-athletes). The specific focus was on the dependency of the head-fake effect on previous fake experience as an index of control over the processing of task-irrelevant gaze information. Whereas (overall) the head-fake effect was of similar size in all expertise groups, preceding fake experience removed the head-fake effect in basketball players, but not in non-experts. Accordingly, basketball expertise allows for higher levels of control over the processing of task-irrelevant gaze information.

  17. [Effect of Epimedium extract on osteoprotegerin and RANKL mRNA expressions in glucocorticoid-induced femoral head necrosis in rats].

    PubMed

    Wang, Jian-zhong; Gao, Hong-yan; Wang, Kun-zheng; Zhou, Rong-xing; Li, Xiao-dong; Guo, Jun; Lv, Hui-cheng

    2011-10-01

    To investigate the effect of glucocorticoid on the expression levels of osteoprotegerin (OPG) and receptor activator of nuclear factor kappa B ligand (RANKL) mRNAs in rat femoral head and the antagonistic effect of Epimedium, and explore the mechanism of Epimedium in preventing glucocorticoid-induced femoral head necrosis. Forty-eight adult SD rats were randomized into glucocorticoid group, Epimedium group and control group. In the former two groups, the rats received intramuscular injection of 12.5 mg prednisolone twice a week, and in Epimedium group, additional 1 ml/100 g aqueous Epimedium extract (equivalent to 0.1 g/ml of the crude drug) was administered intragastrically once daily. The control group received only intramuscular saline injection. After 4 weeks of treatment, osteonecrosis of the left femoral head was detected by HE staining, and the right femoral head was sampled for detection of OPG and RANKL mRNA expressions using real-time quantitative PCR. In glucocorticoid, Epimedium and control groups, the mortality rate of the rats was 12.5% (2/16), 6.25% (1/16), 0 (0/16), and femoral head necrosis occurred at a rate of 71.43% (10/14), 26.67% (4/15), and 0 (0/16), respectively. In glucocorticoid group, the expression level of OPG mRNA was significantly lower, RANKL expression significantly higher, and OPG/RANKL ratio significantly lower than those in Epimedium and control groups (P<0.05). OPG, RANKL and their ratios showed no significant differences between Epimedium group and the control group. Epimedium can prevent glucocorticoid-induced femoral head necrosis probably by antagonizing glucocorticiod-induced abnormal expressions of OPG and RANKL mRNA.

  18. A new saccadic indicator of peripheral vestibular function based on the video head impulse test

    PubMed Central

    MacDougall, Hamish G.; McGarvie, Leigh A.; Rogers, Stephen J.; Manzari, Leonardo; Burgess, Ann M.; Curthoys, Ian S.; Weber, Konrad P.

    2016-01-01

    Objective: While compensatory saccades indicate vestibular loss in the conventional head impulse test paradigm (HIMP), in which the participant fixates an earth-fixed target, we investigated a complementary suppression head impulse paradigm (SHIMP), in which the participant is fixating a head-fixed target to elicit anticompensatory saccades as a sign of vestibular function. Methods: HIMP and SHIMP eye movement responses were measured with the horizontal video head impulse test in patients with unilateral vestibular loss, patients with bilateral vestibular loss, and in healthy controls. Results: Vestibulo-ocular reflex gains showed close correlation (R2 = 0.97) with slightly lower SHIMP than HIMP gains (mean gain difference 0.06 ± 0.05 SD, p < 0.001). However, the 2 paradigms produced complementary catch-up saccade patterns: HIMP elicited compensatory saccades in patients but rarely in controls, whereas SHIMP elicited large anticompensatory saccades in controls, but smaller or no saccades in bilateral vestibular loss. Unilateral vestibular loss produced covert saccades in HIMP, but later and smaller saccades in SHIMP toward the affected side. Cumulative HIMP and SHIMP saccade amplitude differentiated patients from controls with high sensitivity and specificity. Conclusions: While compensatory saccades indicate vestibular loss in conventional HIMP, anticompensatory saccades in SHIMP using a head-fixed target indicate vestibular function. SHIMP saccades usually appear later than HIMP saccades, therefore being more salient to the naked eye and facilitating vestibulo-ocular reflex gain measurements. The new paradigm is intuitive and easy to explain to patients, and the SHIMP results complement those from the standard video head impulse test. Classification of evidence: This case-control study provides Class III evidence that SHIMP accurately identifies patients with unilateral or bilateral vestibulopathies. PMID:27251884

  19. Head-controlled assistive telerobot with extended physiological proprioception capability

    NASA Astrophysics Data System (ADS)

    Salganicoff, Marcos; Rahman, Tariq; Mahoney, Ricardo; Pino, D.; Jayachandran, Vijay; Kumar, Vijay; Chen, Shoupu; Harwin, William S.

    1995-12-01

    People with disabilities such as quadriplegia can use mouth-sticks and head-sticks as extension devices to perform desired manipulations. These extensions provide extended proprioception which allows users to directly feel forces and other perceptual cues such as texture present at the tip of the mouth-stick. Such devices are effective for two principle reasons: because of their close contact with the user's tactile and proprioceptive sensing abilities; and because they tend to be lightweight and very stiff, and can thus convey tactile and kinesthetic information with high-bandwidth. Unfortunately, traditional mouth-sticks and head-sticks are limited in workspace and in the mechanical power that can be transferred because of user mobility and strength limitations. We describe an alternative implementation of the head-stick device using the idea of a virtual head-stick: a head-controlled bilateral force-reflecting telerobot. In this system the end-effector of the slave robot moves as if it were at the tip of an imaginary extension of the user's head. The design goal is for the system is to have the same intuitive operation and extended proprioception as a regular mouth-stick effector but with augmentation of workspace volume and mechanical power. The input is through a specially modified six DOF master robot (a PerForceTM hand-controller) whose joints can be back-driven to apply forces at the user's head. The manipulation tasks in the environment are performed by a six degree-of-freedom slave robot (the Zebra-ZEROTM) with a built-in force sensor. We describe the prototype hardware/software implementation of the system, control system design, safety/disability issues, and initial evaluation tasks.

  20. Critical Views of LCSH--the Library of Congress Subject Headings; A Bibliographic and Bibliometric Essay and An Analysis of Vocabulary Control in the Library of Congress List of Subject Headings (LCSH).

    ERIC Educational Resources Information Center

    Cochrane, Pauline A.; Kirtland, Monika

    A comprehensive guide to the literature published between World War II and 1979 which critically evaluates the Library of Congress list of Subject Headings (LCSH), this bibliography has been prepared for information personnel involved with subject authority files, thesauri, or vocabulary control. A brief bibliometric analysis of the literature…

  1. Synthesis and characterization of silver nanoparticles from (bis)alkylamine silver carboxylate precursors

    NASA Astrophysics Data System (ADS)

    Uznanski, Pawel; Zakrzewska, Joanna; Favier, Frederic; Kazmierski, Slawomir; Bryszewska, Ewa

    2017-03-01

    A comparative study of amine and silver carboxylate adducts [R1COOAg-2(R2NH2)] (R1 = 1, 7, 11; R2 = 8, 12) as a key intermediate in NPs synthesis is carried out via differential scanning calorimetry, solid-state FT-infrared spectroscopy, 13C CP MAS NMR, powder X-ray diffraction and X-ray photoelectron spectroscopy, and various solution NMR spectroscopies (1H and 13C NMR, pulsed field gradient spin-echo NMR, and ROESY). It is proposed that carboxyl moieties in the presence of amine ligands are bound to silver ions via chelating bidentate type of coordination as opposed to bridging bidentate coordination of pure silver carboxylates resulting from the formation of dimeric units. All complexes are packed as lamellar bilayer structures. Silver carboxylate/amine complexes show one first-order melting transition. The evidence presented in this study shows that phase behavior of monovalent metal carboxylates are controlled, mainly, by head group bonding. In solution, insoluble silver salt is stabilized by amine molecules which exist in dynamic equilibrium. Using (bis)amine-silver carboxylate complex as precursor, silver nanoparticles were fabricated. During high-temperature thermolysis, the (bis)amine-carboxylate adduct decomposes to produce silver nanoparticles of small size. NPs are stabilized by strongly interacting carboxylate and trace amounts of amine derived from the silver precursor interacting with carboxylic acid. A corresponding aliphatic amide obtained from silver precursor at high-temperature reaction conditions is not taking part in the stabilization. Combining NMR techniques with FTIR, it was possible to follow an original stabilization mechanism.

  2. Risk genes in head and neck cancer: a systematic review and meta-analysis of last 5 years.

    PubMed

    Brunotto, M; Zarate, A M; Bono, A; Barra, J L; Berra, S

    2014-03-01

    The aim of this work was to identify risk genes related to the development and progression of squamous cell carcinoma head and neck (SCCHN) and do a meta-analysis of available estimates. Eligible gene/polymorphism studies were identified by electronic searches. Individual participant data of 8540 patients with HNC and 9844 controls from 19 genetic studies were analyzed, yielding adjusted (tobacco, gender, age and alcohol) odds ratios (OR) and 95% confidence intervals (CIs) comparing cases with controls. A meta-analysis was done on the studies that applied fixed and random models. People have an increase of polymorphism expression related to inflammation (NFKB1-294-ATTG, TNFα308-A2A2/A2A1, and TNFβ252- B2B2/B2B1) or carcinogenic metabolism (GSTM1 null, and CYP1A1 m1/m1), representative of malignancy development. Furthermore, the increased expression of genes associated with the stabilization and repair of the cellular (OGG1-Asp267Asn, Ser279Gly Ile253Phe, 1578A>T, 1582C>T Ala399Glu (1542C>A) 1582insG 1543_1544delCT), and genes associated with the regulation of proliferation, apoptosis or tumor survival (miRNA499-CT/CC, CRYABC802G-CG/GG) are considered as risk factors. In this scheme, only the polymorphisms of ADH7A92G-GG and DEC1606-T/C genes are protective against malignancy transformation. The TP53, GSTM1 and CYPA1genes have been evaluated in more than one study and analyzed for homogeneity in each genotype. The meta-analysis showed no significant association between different allelic variants of Arg72Pro rs1042522 and SCCHN risk. In a model of tumorigenesis, an increased risk of SCCHN is associated with DNA repair and DNA stabilization genes. In addition, the polymorphisms involved in inflammation and carcinogenic metabolism processes represent an increased risk of SCCHN. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Iturin levels on wheat spikes linked to biological control of fusarium head blight by Bacillus amyloliquefaciens

    USDA-ARS?s Scientific Manuscript database

    The TrigoCor strain of Bacillus amyloliquefaciens provides consistent control against Fusarium head blight of wheat in controlled settings but there is a lack of disease and deoxynivalenol suppression in field settings. Since production of antifungal compounds is thought to be the main mode of actio...

  4. Smart optical writing head design for laser-based manufacturing

    NASA Astrophysics Data System (ADS)

    Amin, M. Junaid; Riza, Nabeel A.

    2014-03-01

    Proposed is a smart optical writing head design suitable for high precision industrial laser based machining and manufacturing applications. The design uses an Electronically Controlled Variable Focus Lens (ECVFL) which enables the highest achievable spatial resolution of writing head spot sizes for axial target distances reaching 8 meters. A proof-of-concept experiment is conducted using a visible wavelength laser with a collimated beam that is coupled to beam conditioning optics which includes an electromagnetically actuated deformable membrane liquid ECVFL cascaded with a bias convex lens of fixed focal length. Electronic tuning and control of the ECVFL keeps the laser writing head far-field spot beam radii under 1 mm that is demonstrated over a target range of 20 cm to 800 cm. Applications for the proposed writing head design, which can accommodate both continuous wave and pulsed wave sources, include laser machining, high precision industrial molding of components, as well as materials processing requiring material sensitive optical power density control.

  5. THE DEVELOPMENT OF SELF-OTHER RELATIONSHIPS DURING PROJECT HEAD START.

    ERIC Educational Resources Information Center

    LAMB, HOWARD E.; AND OTHERS

    PROJECT HEAD START WAS CONCEIVED IN PART, TO INCREASE THE ORDINARILY REDUCED NUMBER OF CONNECTIONS BETWEEN THE CHILD AND OTHER PEOPLE. FOUR QUESTIONS WERE ASKED. (1) WOULD THE DEVELOPMENT OF SELF-SOCIAL CONSTRUCTS OF HEAD START CHILDREN DIFFER FROM THE DEVELOPMENT OF CHILDREN IN A CONTROL GROUP. (2) WOULD HEAD START CHILDREN DEVELOP APPROPRIATE…

  6. Evaluation of Postural Control in Patients with Glaucoma Using a Virtual Reality Environment.

    PubMed

    Diniz-Filho, Alberto; Boer, Erwin R; Gracitelli, Carolina P B; Abe, Ricardo Y; van Driel, Nienke; Yang, Zhiyong; Medeiros, Felipe A

    2015-06-01

    To evaluate postural control using a dynamic virtual reality environment and the relationship between postural metrics and history of falls in patients with glaucoma. Cross-sectional study. The study involved 42 patients with glaucoma with repeatable visual field defects on standard automated perimetry (SAP) and 38 control healthy subjects. Patients underwent evaluation of postural stability by a force platform during presentation of static and dynamic visual stimuli on stereoscopic head-mounted goggles. The dynamic visual stimuli presented rotational and translational ecologically valid peripheral background perturbations. Postural stability was also tested in a completely dark field to assess somatosensory and vestibular contributions to postural control. History of falls was evaluated by a standard questionnaire. Torque moments around the center of foot pressure on the force platform were measured, and the standard deviations of the torque moments (STD) were calculated as a measurement of postural stability and reported in Newton meters (Nm). The association with history of falls was investigated using Poisson regression models. Age, gender, body mass index, severity of visual field defect, best-corrected visual acuity, and STD on dark field condition were included as confounding factors. Patients with glaucoma had larger overall STD than controls during both translational (5.12 ± 2.39 Nm vs. 3.85 ± 1.82 Nm, respectively; P = 0.005) and rotational stimuli (5.60 ± 3.82 Nm vs. 3.93 ± 2.07 Nm, respectively; P = 0.022). Postural metrics obtained during dynamic visual stimuli performed better in explaining history of falls compared with those obtained in static and dark field condition. In the multivariable model, STD values in the mediolateral direction during translational stimulus were significantly associated with a history of falls in patients with glaucoma (incidence rate ratio, 1.85; 95% confidence interval, 1.30-2.63; P = 0.001). The study presented and validated a novel paradigm for evaluation of balance control in patients with glaucoma on the basis of the assessment of postural reactivity to dynamic visual stimuli using a virtual reality environment. The newly developed metrics were associated with a history of falls and may help to provide a better understanding of balance control in patients with glaucoma. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of Postural Control in Glaucoma Patients Using a Virtual 1 Reality Environment

    PubMed Central

    Diniz-Filho, Alberto; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; van Driel, Nienke; Yang, Zhiyong; Medeiros, Felipe A.

    2015-01-01

    Purpose To evaluate postural control using a dynamic virtual reality environment and the relationship between postural metrics and history of falls in glaucoma patients. Design Cross-sectional study. Participants The study involved 42 glaucoma patients with repeatable visual field defects on standard automated perimetry (SAP) and 38 control healthy subjects. Methods Patients underwent evaluation of postural stability by a force platform during presentation of static and dynamic visual stimuli on stereoscopic head-mounted goggles. The dynamic visual stimuli presented rotational and translational ecologically valid peripheral background perturbations. Postural stability was also tested in a completely dark field to assess somatosensory and vestibular contributions to postural control. History of falls was evaluated by a standard questionnaire. Main Outcome Measures Torque moments around the center of foot pressure on the force platform were measured and the standard deviations (STD) of these torque moments were calculated as a measurement of postural stability and reported in Newton meter (Nm). The association with history of falls was investigated using Poisson regression models. Age, gender, body mass index, severity of visual field defect, best-corrected visual acuity, and STD on dark field condition were included as confounding factors. Results Glaucoma patients had larger overall STD than controls during both translational (5.12 ± 2.39 Nm vs. 3.85 ± 1.82 Nm, respectively; P = 0.005) as well as rotational stimuli (5.60 ± 3.82 Nm vs. 3.93 ± 2.07 Nm, respectively; P = 0.022). Postural metrics obtained during dynamic visual stimuli performed better in explaining history of falls compared to those obtained in static and dark field condition. In the multivariable model, STD values in the mediolateral direction during translational stimulus were significantly associated with history of falls in glaucoma patients (incidence-rate ratio = 1.85; 95% CI: 1.30 – 2.63; P = 0.001). Conclusions The study presented and validated a novel paradigm for evaluation of balance control in glaucoma patients based on the assessment of postural reactivity to dynamic visual stimuli using a virtual reality environment. The newly developed metrics were associated with history of falls and may help to provide a better understanding of balance control in glaucoma patients. PMID:25892017

  8. Control of a Quadcopter Aerial Robot Using Optic Flow Sensing

    NASA Astrophysics Data System (ADS)

    Hurd, Michael Brandon

    This thesis focuses on the motion control of a custom-built quadcopter aerial robot using optic flow sensing. Optic flow sensing is a vision-based approach that can provide a robot the ability to fly in global positioning system (GPS) denied environments, such as indoor environments. In this work, optic flow sensors are used to stabilize the motion of quadcopter robot, where an optic flow algorithm is applied to provide odometry measurements to the quadcopter's central processing unit to monitor the flight heading. The optic-flow sensor and algorithm are capable of gathering and processing the images at 250 frames/sec, and the sensor package weighs 2.5 g and has a footprint of 6 cm2 in area. The odometry value from the optic flow sensor is then used a feedback information in a simple proportional-integral-derivative (PID) controller on the quadcopter. Experimental results are presented to demonstrate the effectiveness of using optic flow for controlling the motion of the quadcopter aerial robot. The technique presented herein can be applied to different types of aerial robotic systems or unmanned aerial vehicles (UAVs), as well as unmanned ground vehicles (UGV).

  9. Impact angle constrained three-dimensional integrated guidance and control for STT missile in the presence of input saturation.

    PubMed

    Wang, Sen; Wang, Weihong; Xiong, Shaofeng

    2016-09-01

    Considering a class of skid-to-turn (STT) missile with fixed target and constrained terminal impact angles, a novel three-dimensional (3D) integrated guidance and control (IGC) scheme is proposed in this paper. Based on coriolis theorem, the fully nonlinear IGC model without the assumption that the missile flies heading to the target at initial time is established in the three-dimensional space. For this strict-feedback form of multi-variable system, dynamic surface control algorithm is implemented combining with extended observer (ESO) to complete the preliminary design. Then, in order to deal with the problems of the input constraints, a hyperbolic tangent function is introduced to approximate the saturation function and auxiliary system including a Nussbaum function established to compensate for the approximation error. The stability of the closed-loop system is proven based on Lyapunov theory. Numerical simulations results show that the proposed integrated guidance and control algorithm can ensure the accuracy of target interception with initial alignment angle deviation and the input saturation is suppressed with smooth deflection curves. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Interaction of feel system and flight control system dynamics on lateral flying qualities

    NASA Technical Reports Server (NTRS)

    Bailey, R. E.; Knotts, L. H.

    1990-01-01

    An experimental investigation of the influence of lateral feel system characteristics on fighter aircraft roll flying qualities was conducted using the variable stability USAF NT-33. Forty-two evaluation flights were flown by three engineering test pilots. The investigation utilized the power approach, visual landing task and up-and-away tasks including formation, gun tracking, and computer-generated compensatory attitude tracking tasks displayed on the Head-Up Display. Experimental variations included the feel system frequency, force-deflection gradient, control system command type (force or position input command), aircraft roll mode time constant, control system prefilter frequency, and control system time delay. The primary data were task performance records and evaluation pilot comments and ratings using the Cooper-Harper scale. The data highlight the unique and powerful effect of the feel system of flying qualities. The data show that the feel system is not 'equivalent' in flying qualities influence to analogous control system elements. A lower limit of allowable feel system frequency appears warranted to ensure good lateral flying qualities. Flying qualities criteria should most properly treat the feel system dynamic influence separately from the control system, since the input and output of this dynamic element is apparent to the pilot and thus, does not produce a 'hidden' effect.

  11. Effects of Airport Tower Controller Decision Support Tool on Controllers Head-Up Time

    NASA Technical Reports Server (NTRS)

    Hayashi, Miwa; Cruz Lopez, Jose M.

    2013-01-01

    Despite that aircraft positions and movements can be easily monitored on the radar displays at major airports nowadays, it is still important for the air traffic control tower (ATCT) controllers to look outside the window as much as possible to assure safe operations of traffic management. The present paper investigates whether an introduction of the NASA's proposed Spot and Runway Departure Advisor (SARDA), a decision support tool for the ATCT controller, would increase or decrease the controllers' head-up time. SARDA provides the controller departure-release schedule advisories, i.e., when to release each departure aircraft in order to minimize individual aircraft's fuel consumption on taxiways and simultaneously maximize the overall runway throughput. The SARDA advisories were presented on electronic flight strips (EFS). To investigate effects on the head-up time, a human-in-the-loop simulation experiment with two retired ATCT controller participants was conducted in a high-fidelity ATCT cab simulator with 360-degree computer-generated out-the-window view. Each controller participant wore a wearable video camera on a side of their head with the camera facing forward. The video data were later used to calculate their line of sight at each moment and eventually identify their head-up times. Four sessions were run with the SARDA advisories, and four sessions were run without (baseline). Traffic-load levels were varied in each session. The same set of user interface - EFS and the radar displays - were used in both the advisory and baseline sessions to make them directly comparable. The paper reports the findings and discusses their implications.

  12. Could head circumference be used to screen for autism in young males with developmental delay?

    PubMed

    Gray, Kylie M; Taffe, John; Sweeney, Deborah J; Forster, Sheridan; Tonge, Bruce J

    2012-04-01

    Research has suggested an abnormal acceleration in head circumference growth in children with autism within the first 12 months of life. This study aimed to examine head circumference at birth and head circumference growth rates in young children with autism and developmental delay, and young children with developmental delay without autism. This study assessed head circumference at birth and rate of change in head circumference in young children with autism (n=86) and children with developmental delay without autism (n=40). For both groups of children, head circumference at birth and head circumference growth were compared with Centers for Disease Control normative data. No differences were found between the group of children with autism and developmental delay compared with the group with developmental delay only. However, when the sample was compared with a range of selected Centers for Disease Control normative medians, the children with autism were found to have significantly smaller head circumferences at birth and significantly larger head circumference at 18.5 months of age. These results are discussed in relation to the potential of accelerated head circumference growth as an early marker for autism. This study failed to find a difference in the head circumferences of children with autism and developmental delay and children with developmental delay only, thus suggesting that head circumference measurement has limited value as an early marker for autism. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  13. Reduced head-neck offset in nontraumatic osteonecrosis of the femoral head.

    PubMed

    Fraitzl, Christian R; Kappe, Thomas; Brugger, Annina; Billich, Christian; Reichel, Heiko

    2013-08-01

    Risk factors for nontraumatic osteonecrosis of the femoral head have in common that they trigger intravascular coagulation and thus lead to devascularization of the femoral head. In part of the patients, however, no risk factors seem to be evident. Mechanical reasons contributing to nontraumatic osteonecrosis have not been discussed so far. We hypothesized that recurrent traumatization of the vessels supplying the femoral head by a cam-type mechanism as in femoroacetabular impingement could add to intravascular coagulation. We, therefore, asked whether structural abnormalities at the femoral head-neck junction indicative of such a mechanism could be observed in radiographs of patients with osteonecrosis of the femoral head. The preoperative anteroposterior and lateral radiographs of 77 patients who underwent surgery because of osteonecrosis of the femoral head were retrospectively screened for a reduced head-neck offset by measuring the α-angle. For comparison, the α-angle was measured on anteroposterior and lateral radiographs of 339 control subjects without evident underlying hip pathology. The mean α-angle was 62.8° (SD 18.7°) for anteroposterior and 67.6° (SD 13.2°) for lateral radiographs in patients with nontraumatic osteonecrosis of the femoral head, whereas in control subjects, the mean α-angle was 47.2° (SD 9.6°) (p < 0.0001) and 47.6° (SD 10.3°) (p < 0.0001), respectively. A reduced head-neck offset in patients with nontraumatic osteonecrosis of the femoral head may act as a mechanical (co-)factor in developing osteonecrosis of the femoral head.

  14. Early Results of a Helmetless-Tackling Intervention to Decrease Head Impacts in Football Players

    PubMed Central

    Swartz, Erik E.; Broglio, Steven P.; Cook, Summer B.; Cantu, Robert C.; Ferrara, Michael S.; Guskiewicz, Kevin M.; Myers, Jay L.

    2015-01-01

    Objective To test a helmetless-tackling behavioral intervention for reducing head impacts in National Collegiate Athletic Association Division I football players. Design Randomized controlled clinical trial. Setting Football field. Patients or Other Participants Fifty collegiate football players (intervention = 25, control = 25). Intervention(s) The intervention group participated in a 5-minute tackling drill without their helmets and shoulder pads twice per week in the preseason and once per week through the season. During this time, the control group performed noncontact football skills. Main Outcome Measure(s) Frequency of head impacts was recorded by an impact sensor for each athlete-exposure (AE). Data were tested with a 2 × 3 (group and time) repeated-measures analysis of variance. Significant interactions and main effects (P < .05) were followed with t tests. Results Head impacts/AE decreased for the intervention group compared with the control group by the end of the season (9.99 ± 6.10 versus 13.84 ± 7.27, respectively). The intervention group had 30% fewer impacts/AE than the control group by season's end (9.99 ± 6.10 versus 14.32 ± 8.45, respectively). Conclusion A helmetless-tackling training intervention reduced head impacts in collegiate football players within 1 season. PMID:26651278

  15. Linking lipid architecture to bilayer structure and mechanics using self-consistent field modelling.

    PubMed

    Pera, H; Kleijn, J M; Leermakers, F A M

    2014-02-14

    To understand how lipid architecture determines the lipid bilayer structure and its mechanics, we implement a molecularly detailed model that uses the self-consistent field theory. This numerical model accurately predicts parameters such as Helfrichs mean and Gaussian bending modulus kc and k̄ and the preferred monolayer curvature J(0)(m), and also delivers structural membrane properties like the core thickness, and head group position and orientation. We studied how these mechanical parameters vary with system variations, such as lipid tail length, membrane composition, and those parameters that control the lipid tail and head group solvent quality. For the membrane composition, negatively charged phosphatidylglycerol (PG) or zwitterionic, phosphatidylcholine (PC), and -ethanolamine (PE) lipids were used. In line with experimental findings, we find that the values of kc and the area compression modulus kA are always positive. They respond similarly to parameters that affect the core thickness, but differently to parameters that affect the head group properties. We found that the trends for k̄ and J(0)(m) can be rationalised by the concept of Israelachivili's surfactant packing parameter, and that both k̄ and J(0)(m) change sign with relevant parameter changes. Although typically k̄ < 0, membranes can form stable cubic phases when the Gaussian bending modulus becomes positive, which occurs with membranes composed of PC lipids with long tails. Similarly, negative monolayer curvatures appear when a small head group such as PE is combined with long lipid tails, which hints towards the stability of inverse hexagonal phases at the cost of the bilayer topology. To prevent the destabilisation of bilayers, PG lipids can be mixed into these PC or PE lipid membranes. Progressive loading of bilayers with PG lipids lead to highly charged membranes, resulting in J(0)(m) > 0, especially at low ionic strengths. We anticipate that these changes lead to unstable membranes as these become vulnerable to pore formation or disintegration into lipid disks.

  16. The association of temporomandibular disorder pain with history of head and neck injury in adolescents.

    PubMed

    Fischer, Dena J; Mueller, Beth A; Critchlow, Cathy W; LeResche, Linda

    2006-01-01

    To evaluate the risk of self-reported temporomandibular disorder (TMD) pain among adolescents in relation to previous head and/or neck injury. 3,101 enrollees (11 to 17 years of age) of a nonprofit integrated health-care system were interviewed by telephone. Two hundred four cases with self-reported TMD pain and 194 controls without self-reported TMD pain frequency-matched to the cases by age and gender completed standardized in-person interviews and physical examinations in which reports of previous head/neck injuries were recorded. Odds ratio (OR) estimates and 95% confidence intervals (CIs) of the relative risks of TMD pain associated with prior head and/or neck injuries were calculated using logistic regression. A greater proportion of subjects reporting TMD pain (36%) than controls (25%) had a history of head and/or neck injuries (OR = 1.8, 95% CI, 1.1-2.8). In a separate analysis, the presence of TMD based upon the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) was assessed in relation to prior head and/or neck injury. Cases reporting TMD pain and meeting the RDC/TMD criteria for myofascial pain and/or arthralgia or arthritis were 2.0 (CI, 1.0-3.8) times more likely to have had a prior head injury than were controls with neither self-reported nor RDC/TMD pain diagnoses. The results suggest a modest association of prior head injuries with both self-reported and clinically diagnosed TMD pain in adolescents.

  17. Motivating drivers to correctly adjust head restraints: assessing effectiveness of three different interventions.

    PubMed

    Fockler, S K; Vavrik, J; Kristiansen, L

    1998-11-01

    Three types of driver educational strategies were tested to determine the most effective approach for motivating drivers to adjust their head restraints to the correct vertical position: (1) a human interactive personal contact with a member of an ICBC-trained head restraint adjustment team, (2) a passive video presentation of the consequences of correct and incorrect head restraint adjustment, and (3) an interactive three-dimensional kinetic model showing the consequences of correct and incorrect head restraint adjustment. An experimental pretest-posttest control group design was used. A different educational treatment was used in each of three lanes of a vehicle emissions testing facility, with a fourth lane with no intervention serving as a control group. Observational and self-reported data were obtained from a total of 1,974 vehicles entering and exiting the facility. The human intervention led to significantly more drivers actually adjusting their head restraints immediately after the intervention than the passive video or interactive kinetic model approaches, which were both no different from the control group. The human intervention was recommended as the most effective and was implemented successfully on a limited basis during 3 months of 1995 and again during 3 months of 1996.

  18. A programmable DNA origami nanospring that reveals force-induced adjacent binding of myosin VI heads

    PubMed Central

    Iwaki, M.; Wickham, S. F.; Ikezaki, K.; Yanagida, T.; Shih, W. M.

    2016-01-01

    Mechanosensitive biological nanomachines such as motor proteins and ion channels regulate diverse cellular behaviour. Combined optical trapping with single-molecule fluorescence imaging provides a powerful methodology to clearly characterize the mechanoresponse, structural dynamics and stability of such nanomachines. However, this system requires complicated experimental geometry, preparation and optics, and is limited by low data-acquisition efficiency. Here we develop a programmable DNA origami nanospring that overcomes these issues. We apply our nanospring to human myosin VI, a mechanosensory motor protein, and demonstrate nanometre-precision single-molecule fluorescence imaging of the individual motor domains (heads) under force. We observe force-induced transitions of myosin VI heads from non-adjacent to adjacent binding, which correspond to adapted roles for low-load and high-load transport, respectively. Our technique extends single-molecule studies under force and clarifies the effect of force on biological processes. PMID:27941751

  19. A programmable DNA origami nanospring that reveals force-induced adjacent binding of myosin VI heads.

    PubMed

    Iwaki, M; Wickham, S F; Ikezaki, K; Yanagida, T; Shih, W M

    2016-12-12

    Mechanosensitive biological nanomachines such as motor proteins and ion channels regulate diverse cellular behaviour. Combined optical trapping with single-molecule fluorescence imaging provides a powerful methodology to clearly characterize the mechanoresponse, structural dynamics and stability of such nanomachines. However, this system requires complicated experimental geometry, preparation and optics, and is limited by low data-acquisition efficiency. Here we develop a programmable DNA origami nanospring that overcomes these issues. We apply our nanospring to human myosin VI, a mechanosensory motor protein, and demonstrate nanometre-precision single-molecule fluorescence imaging of the individual motor domains (heads) under force. We observe force-induced transitions of myosin VI heads from non-adjacent to adjacent binding, which correspond to adapted roles for low-load and high-load transport, respectively. Our technique extends single-molecule studies under force and clarifies the effect of force on biological processes.

  20. Carcinomatous myelitis and meningitis after a squamous cell carcinoma of the lip.

    PubMed

    Pougnet, Isabelle; Murati, Anne; Sarran, Anthony; Viens, Patrice; Sabatier, Renaud

    2014-01-01

    Nervous central system metastases from head and neck squamous cell carcinoma (SCC) are rare. We report an exceptional case of isolated leptomeningeal and spinal cord involvement few years after the diagnosis of invasive SCC of the lip. A 33-year-old man with a history of infracentimetric carcinoma of the lip developed back pain associated with progressive neurological disorders leading to paraplegia. This atypical presentation led to initial misdiagnosis, but radiological and cytological explorations finally confirmed the diagnosis of leptomeningeal and intramedullar secondary spinal cord lesions from his previously treated head and neck SCC. Systemic targeted therapy with epidermal growth factor receptor inhibitor and intrathecal chemotherapy led to prolonged disease stabilization. To our knowledge, this is the first case of isolated neurological metastases from a head and neck SCC. Combination of systemic targeted therapy and intrathecal chemotherapy may be effective in such cases.

Top