Sample records for heading reference systems

  1. 76 FR 80447 - Eighth Meeting: RTCA Special Committee 219: Attitude and Heading Reference Systems (AHRS)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-23

    ... Committee 219: Attitude and Heading Reference Systems (AHRS) AGENCY: Federal Aviation Administration (FAA), U.S. Department of Transportation (DOT). ACTION: Notice of RTCA Special Committee 219: Attitude and... eighth meeting of RTCA Special Committee 219: Attitude and Heading Reference Systems (AHRS). DATES: The...

  2. 76 FR 50810 - Seventh Meeting: RTCA Special Committee 219: Attitude and Heading Reference System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-16

    ... Committee 219: Attitude and Heading Reference System AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of RTCA Special Committee 219 meeting: Attitude and Heading Reference System. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 219: Attitude...

  3. 75 FR 49550 - Fifth Meeting: RTCA Special Committee 219: Attitude and Heading Reference System (AHRS)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-13

    ... 219: Attitude and Heading Reference System (AHRS) AGENCY: Federal Aviation Administration (FAA), Department of Transportation (DOT). ACTION: Notice of RTCA Special Committee 219: Attitude and Heading... 49551

  4. Tool calibration system for micromachining system

    DOEpatents

    Miller, Donald M.

    1979-03-06

    A tool calibration system including a tool calibration fixture and a tool height and offset calibration insert for calibrating the position of a tool bit in a micromachining tool system. The tool calibration fixture comprises a yokelike structure having a triangular head, a cavity in the triangular head, and a port which communicates a side of the triangular head with the cavity. Yoke arms integral with the triangular head extend along each side of a tool bar and a tool head of the micromachining tool system. The yoke arms are secured to the tool bar to place the cavity around a tool bit which may be mounted to the end of the tool head. Three linear variable differential transformer's (LVDT) are adjustably mounted in the triangular head along an X axis, a Y axis, and a Z axis. The calibration insert comprises a main base which can be mounted in the tool head of the micromachining tool system in place of a tool holder and a reference projection extending from a front surface of the main base. Reference surfaces of the calibration insert and a reference surface on a tool bar standard length are used to set the three LVDT's of the calibration fixture to the tool reference position. These positions are transferred permanently to a mastering station. The tool calibration fixture is then used to transfer the tool reference position of the mastering station to the tool bit.

  5. 75 FR 81424 - Airworthiness Directives; Sikorsky Aircraft Corporation (Sikorsky) Model S76A, B, and C Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-28

    .... The EAD requires inspecting the LITEF Attitude Heading and Reference System (AHRS) unit of the...: Model S-76A, B, and C helicopters, with LITEF LCR-100, Attitude Heading and Reference System (AHRS) Unit...

  6. Attitude Heading Reference System Using MEMS Inertial Sensors with Dual-Axis Rotation

    PubMed Central

    Kang, Li; Ye, Lingyun; Song, Kaichen; Zhou, Yang

    2014-01-01

    This paper proposes a low cost and small size attitude and heading reference system based on MEMS inertial sensors. A dual-axis rotation structure with a proper rotary scheme according to the design principles is applied in the system to compensate for the attitude and heading drift caused by the large gyroscope biases. An optimization algorithm is applied to compensate for the installation angle error between the body frame and the rotation table's frame. Simulations and experiments are carried out to evaluate the performance of the AHRS. The results show that the proper rotation could significantly reduce the attitude and heading drifts. Moreover, the new AHRS is not affected by magnetic interference. After the rotation, the attitude and heading are almost just oscillating in a range. The attitude error is about 3° and the heading error is less than 3° which are at least 5 times better than the non-rotation condition. PMID:25268911

  7. Comparison of complementary and Kalman filter based data fusion for attitude heading reference system

    NASA Astrophysics Data System (ADS)

    Islam, Tariqul; Islam, Md. Saiful; Shajid-Ul-Mahmud, Md.; Hossam-E-Haider, Md

    2017-12-01

    An Attitude Heading Reference System (AHRS) provides 3D orientation of an aircraft (roll, pitch, and yaw) with instantaneous position and also heading information. For implementation of a low cost AHRS system Micro-electrical-Mechanical system (MEMS) based sensors are used such as accelerometer, gyroscope, and magnetometer. Accelerometers suffer from errors caused by external accelerations that sums to gravity and make accelerometers based rotation inaccurate. Gyroscopes can remove such errors but create drifting problems. So for getting the precise data additionally two very common and well known filters Complementary and Kalman are introduced to the system. In this paper a comparison of system performance using these two filters is shown separately so that one would be able to select filter with better performance for his/her system.

  8. Eye point-of-regard system

    NASA Technical Reports Server (NTRS)

    Jex, H. R.

    1971-01-01

    System measures intersection of line of sight and eye point of regard /EPR/ for a human operator in visual scanning system. Device measures two head to reference angles with EPR system and adds them with eye to head angles, yielding a dc signal proportional to picture plane coordinates.

  9. Identification and Validation of Reference Genes for RT-qPCR Analysis in Non-Heading Chinese Cabbage Flowers

    PubMed Central

    Wang, Cheng; Cui, Hong-Mi; Huang, Tian-Hong; Liu, Tong-Kun; Hou, Xi-Lin; Li, Ying

    2016-01-01

    Non-heading Chinese cabbage (Brassica rapa ssp. chinensis Makino) is an important vegetable member of Brassica rapa crops. It exhibits a typical sporophytic self-incompatibility (SI) system and is an ideal model plant to explore the mechanism of SI. Gene expression research are frequently used to unravel the complex genetic mechanism and in such studies appropriate reference selection is vital. Validation of reference genes have neither been conducted in Brassica rapa flowers nor in SI trait. In this study, 13 candidate reference genes were selected and examined systematically in 96 non-heading Chinese cabbage flower samples that represent four strategic groups in compatible and self-incompatible lines of non-heading Chinese cabbage. Two RT-qPCR analysis software, geNorm and NormFinder, were used to evaluate the expression stability of these genes systematically. Results revealed that best-ranked references genes should be selected according to specific sample subsets. DNAJ, UKN1, and PP2A were identified as the most stable reference genes among all samples. Moreover, our research further revealed that the widely used reference genes, CYP and ACP, were the least suitable reference genes in most non-heading Chinese cabbage flower sample sets. To further validate the suitability of the reference genes identified in this study, the expression level of SRK and Exo70A1 genes which play important roles in regulating interaction between pollen and stigma were studied. Our study presented the first systematic study of reference gene(s) selection for SI study and provided guidelines to obtain more accurate RT-qPCR results in non-heading Chinese cabbage. PMID:27375663

  10. Position detectors, methods of detecting position, and methods of providing positional detectors

    DOEpatents

    Weinberg, David M.; Harding, L. Dean; Larsen, Eric D.

    2002-01-01

    Position detectors, welding system position detectors, methods of detecting various positions, and methods of providing position detectors are described. In one embodiment, a welding system positional detector includes a base that is configured to engage and be moved along a curved surface of a welding work piece. At least one position detection apparatus is provided and is connected with the base and configured to measure angular position of the detector relative to a reference vector. In another embodiment, a welding system positional detector includes a weld head and at least one inclinometer mounted on the weld head. The one inclinometer is configured to develop positional data relative to a reference vector and the position of the weld head on a non-planar weldable work piece.

  11. Isolating Observer-Based Reference Directions in Human Spatial Memory: Head, Body, and the Self-to-Array Axis

    ERIC Educational Resources Information Center

    Waller, David; Lippa, Yvonne; Richardson, Adam

    2008-01-01

    Several lines of research have suggested the importance of egocentric reference systems for determining how the spatial properties of one's environment are mentally organized. Yet relatively little is known about the bases for egocentric reference systems in human spatial memory. In three experiments, we examine the relative importance of…

  12. Coordinates of Human Visual and Inertial Heading Perception.

    PubMed

    Crane, Benjamin Thomas

    2015-01-01

    Heading estimation involves both inertial and visual cues. Inertial motion is sensed by the labyrinth, somatic sensation by the body, and optic flow by the retina. Because the eye and head are mobile these stimuli are sensed relative to different reference frames and it remains unclear if a perception occurs in a common reference frame. Recent neurophysiologic evidence has suggested the reference frames remain separate even at higher levels of processing but has not addressed the resulting perception. Seven human subjects experienced a 2s, 16 cm/s translation and/or a visual stimulus corresponding with this translation. For each condition 72 stimuli (360° in 5° increments) were delivered in random order. After each stimulus the subject identified the perceived heading using a mechanical dial. Some trial blocks included interleaved conditions in which the influence of ±28° of gaze and/or head position were examined. The observations were fit using a two degree-of-freedom population vector decoder (PVD) model which considered the relative sensitivity to lateral motion and coordinate system offset. For visual stimuli gaze shifts caused shifts in perceived head estimates in the direction opposite the gaze shift in all subjects. These perceptual shifts averaged 13 ± 2° for eye only gaze shifts and 17 ± 2° for eye-head gaze shifts. This finding indicates visual headings are biased towards retina coordinates. Similar gaze and head direction shifts prior to inertial headings had no significant influence on heading direction. Thus inertial headings are perceived in body-centered coordinates. Combined visual and inertial stimuli yielded intermediate results.

  13. Coordinates of Human Visual and Inertial Heading Perception

    PubMed Central

    Crane, Benjamin Thomas

    2015-01-01

    Heading estimation involves both inertial and visual cues. Inertial motion is sensed by the labyrinth, somatic sensation by the body, and optic flow by the retina. Because the eye and head are mobile these stimuli are sensed relative to different reference frames and it remains unclear if a perception occurs in a common reference frame. Recent neurophysiologic evidence has suggested the reference frames remain separate even at higher levels of processing but has not addressed the resulting perception. Seven human subjects experienced a 2s, 16 cm/s translation and/or a visual stimulus corresponding with this translation. For each condition 72 stimuli (360° in 5° increments) were delivered in random order. After each stimulus the subject identified the perceived heading using a mechanical dial. Some trial blocks included interleaved conditions in which the influence of ±28° of gaze and/or head position were examined. The observations were fit using a two degree-of-freedom population vector decoder (PVD) model which considered the relative sensitivity to lateral motion and coordinate system offset. For visual stimuli gaze shifts caused shifts in perceived head estimates in the direction opposite the gaze shift in all subjects. These perceptual shifts averaged 13 ± 2° for eye only gaze shifts and 17 ± 2° for eye-head gaze shifts. This finding indicates visual headings are biased towards retina coordinates. Similar gaze and head direction shifts prior to inertial headings had no significant influence on heading direction. Thus inertial headings are perceived in body-centered coordinates. Combined visual and inertial stimuli yielded intermediate results. PMID:26267865

  14. HEAD CIRCUMFERENCE REFERENCES FOR SCHOOL AGE CHILDREN IN WESTERN ROMANIA.

    PubMed

    Chirita-Emandi, Adela; Doros, Gabriela; Simina, Iulia Jurca; Gafencu, Mihai; Puiu, Maria

    2015-01-01

    To provide head circumference references for school-aged children in western Romania, and compare them with references from other European countries. A total of 2742 children, aged 6-19 years, from Timis county, were examined by medical students, between February 2010-June 2011. Head circumference references were constructed by Cole's LMS method with LMSChartMaker software. The Romanian 3rd, 50th and 97th percentiles for head circumference were compared with recent references from Belgium and Germany. Generally, boys show significantly larger head circumference compared to girls at any age. The head circumference increments between 6 and 19 years are < 1 cm/year. Head circumference increments decrease in increasing age of the children. In girls, adult head circumference is reached at the age of 16 years, whereas head circumference growth continues, in boys, slowly until 18 years. The comparison of Romanian head percentiles with those from Belgium and Germany revealed a smaller head circumference in Romanian children (both girls and boys). Comparing head circumference references from Romania to those from Germany and Belgium, we found lower median head circumference in Romanian boys and girls, that could be explained by a taller stature of boys and girls in Germany and Belgium compared to Romania.

  15. Gain-Scheduled Complementary Filter Design for a MEMS Based Attitude and Heading Reference System

    PubMed Central

    Yoo, Tae Suk; Hong, Sung Kyung; Yoon, Hyok Min; Park, Sungsu

    2011-01-01

    This paper describes a robust and simple algorithm for an attitude and heading reference system (AHRS) based on low-cost MEMS inertial and magnetic sensors. The proposed approach relies on a gain-scheduled complementary filter, augmented by an acceleration-based switching architecture to yield robust performance, even when the vehicle is subject to strong accelerations. Experimental results are provided for a road captive test during which the vehicle dynamics are in high-acceleration mode and the performance of the proposed filter is evaluated against the output from a conventional linear complementary filter. PMID:22163824

  16. HPAC info-dex 2 -- Locating a product

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-06-01

    Products for mechanical systems are listed in more than 1,200 categories, and under each heading are the names of the manufactures supplying that product. Cross references make it easy to find the products you need. The headings are arranged by the governing noun; for example, Butterfly Valves'' will be found under Valves, Butterfly''. Companies shown in boldface type have page number references directing you to their advertised product information in HPAC Info-dex 6, starting on page 112.

  17. Experimental procedure for measuring and comparing head-neck-trunk posture and movements caused by different progressive addition lens designs.

    PubMed

    Mateo, B; Porcar-Seder, R; Solaz, J S; Dürsteler, J C

    2010-07-01

    This study demonstrates that appropriate measurement procedures can detect differences in head movement in a near reading task when using three different progressive addition lenses (PALs). The movements were measured using an anatomical reference system with a biomechanical rationale. This reference system was capable of representing rotations for comparing head flexion relative to trunk, head flexion relative to neck, head rotation relative to trunk and trunk flexion. The subject sample comprised 31 volunteers and three PAL designs with different viewing zones were selected. Significant differences were found between the lenses for three of the seven movement parameters examined. The differences occurred for both vertical and horizontal head movements and could be attributed to aspects of the PAL design. The measurement of the complete kinematic trunk-neck-head chain improved the number of differences that were found over those in previous studies. STATEMENT OF RELEVANCE: The study proposes a methodology based on a biomechanical rationale able to differentiate head-neck-trunk posture and movements caused by different progressive addition lens designs with minimum invasiveness. This methodology could also be applied to analyse the ergonomics of other devices that restrict the user's field of view, such as helmets, personal protective equipment or helmet-mounted displays for pilots. This analysis will allow designers to optimise designs offering higher comfort and performance.

  18. 78 FR 32078 - Special Conditions: Gulfstream Model G280 Airplane, Enhanced Flight Vision System (EFVS) With...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-29

    ... document refers to a system comprised of a head-up display, imaging sensor(s), and avionics interfaces that display the sensor imagery on the HUD, and which overlay that imagery with alpha-numeric and symbolic... the sensor imagery, with or without other flight information, on a head-down display. For clarity, the...

  19. Allocentric-heading recall and its relation to self-reported sense-of-direction.

    PubMed

    Sholl, M Jeanne; Kenny, Ryan J; DellaPorta, Katherine A

    2006-05-01

    A sense of direction (SOD) computes the body's facing direction relative to a reference frame grounded in the environment. The authors report on three experiments in which they used a heading-recall task to tap the functioning of a SOD system and then correlated task performance with self-reported SOD as a convergent test of the task's construct validity. On each heading-recall trial, the participant judged the photographer's allocentric heading when photographing a pictured outdoor scene. Participants were tested over the full range of SOD ratings in Experiment 1, and in Experiments 2 and 3 heading-recall at the SOD extremes was tested. In all experiments, there was wide variability in heading-recall accuracy that covaried with self-rated SOD. Parametric manipulation of various task parameters revealed some likely functional properties of the SOD system. The results support the psychological reality of a SOD system and further indicate that there are large individual differences in the efficacy with which the system functions.

  20. Wave-Ice Interaction and the Marginal Ice Zone

    DTIC Science & Technology

    2013-09-30

    concept, using a high-quality attitude and heading reference system ( AHRS ) together with an accurate twin-antennae GPS compass. The instruments logged...the AHRS parameters at 50Hz, together with GPS-derived fixes, heading (accurate to better than 1o) and velocities at 10Hz. The 30MB hourly files

  1. Application of Optical Flow Sensors for Dead Reckoning, Heading Reference, Obstacle Detection, and Obstacle Avoidance

    DTIC Science & Technology

    2015-09-01

    OPTICAL FLOW SENSORS FOR DEAD RECKONING, HEADING REFERENCE, OBSTACLE DETECTION, AND OBSTACLE AVOIDANCE by Tarek M. Nejah September 2015...SENSORS FOR DEAD RECKONING, HEADING REFERENCE, OBSTACLE DETECTION, AND OBSTACLE AVOIDANCE 5. FUNDING NUMBERS 6. AUTHOR(S) Nejah, Tarek M. 7...DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) A novel approach for dead reckoning, heading reference, obstacle detection, and obstacle

  2. Quaternion-Based Unscented Kalman Filter for Accurate Indoor Heading Estimation Using Wearable Multi-Sensor System

    PubMed Central

    Yuan, Xuebing; Yu, Shuai; Zhang, Shengzhi; Wang, Guoping; Liu, Sheng

    2015-01-01

    Inertial navigation based on micro-electromechanical system (MEMS) inertial measurement units (IMUs) has attracted numerous researchers due to its high reliability and independence. The heading estimation, as one of the most important parts of inertial navigation, has been a research focus in this field. Heading estimation using magnetometers is perturbed by magnetic disturbances, such as indoor concrete structures and electronic equipment. The MEMS gyroscope is also used for heading estimation. However, the accuracy of gyroscope is unreliable with time. In this paper, a wearable multi-sensor system has been designed to obtain the high-accuracy indoor heading estimation, according to a quaternion-based unscented Kalman filter (UKF) algorithm. The proposed multi-sensor system including one three-axis accelerometer, three single-axis gyroscopes, one three-axis magnetometer and one microprocessor minimizes the size and cost. The wearable multi-sensor system was fixed on waist of pedestrian and the quadrotor unmanned aerial vehicle (UAV) for heading estimation experiments in our college building. The results show that the mean heading estimation errors are less 10° and 5° to multi-sensor system fixed on waist of pedestrian and the quadrotor UAV, respectively, compared to the reference path. PMID:25961384

  3. A DDC Bibliography on Computers in Information Sciences. Volume I. Information Sciences Series.

    ERIC Educational Resources Information Center

    Defense Documentation Center, Alexandria, VA.

    The unclassified and unlimited bibliography compiles references dealing specifically with the role of computers in information sciences. The volume contains 249 annotated references grouped under two major headings: Time Shared, On-Line, and Real Time Systems, and Computer Components. The references are arranged in accesion number (AD-number)…

  4. Judging sound rotation when listeners and sounds rotate: Sound source localization is a multisystem process.

    PubMed

    Yost, William A; Zhong, Xuan; Najam, Anbar

    2015-11-01

    In four experiments listeners were rotated or were stationary. Sounds came from a stationary loudspeaker or rotated from loudspeaker to loudspeaker around an azimuth array. When either sounds or listeners rotate the auditory cues used for sound source localization change, but in the everyday world listeners perceive sound rotation only when sounds rotate not when listeners rotate. In the everyday world sound source locations are referenced to positions in the environment (a world-centric reference system). The auditory cues for sound source location indicate locations relative to the head (a head-centric reference system), not locations relative to the world. This paper deals with a general hypothesis that the world-centric location of sound sources requires the auditory system to have information about auditory cues used for sound source location and cues about head position. The use of visual and vestibular information in determining rotating head position in sound rotation perception was investigated. The experiments show that sound rotation perception when sources and listeners rotate was based on acoustic, visual, and, perhaps, vestibular information. The findings are consistent with the general hypotheses and suggest that sound source localization is not based just on acoustics. It is a multisystem process.

  5. Bibliography on School Buildings.

    ERIC Educational Resources Information Center

    Nomani, M. S.; Srivastava, R. D.

    This bibliography comprises 153 references with abstracts on school building publications published during the period of 1960-1966. The references have been grouped under seven headings--(1) air conditioning and ventilation, (2) bibliography and research reports, (3) construction systems, (4) design development, (5) furniture, (6) lighting, and…

  6. Optical seismic sensor systems and methods

    DOEpatents

    Beal, A. Craig; Cummings, Malcolm E.; Zavriyev, Anton; Christensen, Caleb A.; Lee, Keun

    2015-12-08

    Disclosed is an optical seismic sensor system for measuring seismic events in a geological formation, including a surface unit for generating and processing an optical signal, and a sensor device optically connected to the surface unit for receiving the optical signal over an optical conduit. The sensor device includes at least one sensor head for sensing a seismic disturbance from at least one direction during a deployment of the sensor device within a borehole of the geological formation. The sensor head includes a frame and a reference mass attached to the frame via at least one flexure, such that movement of the reference mass relative to the frame is constrained to a single predetermined path.

  7. California oaks: a bibliography

    Treesearch

    James R. Griffin; Philip M. McDonald; Pamela C. Muick

    1987-01-01

    Among natural resource professionals, California oaks continue to attract considerable attention. This report provides a comprehensive bibliography of the extensive but scattered oak literature. The 768 references are organized into two systems: (a) a topical outline, in which references are displayed under key word headings and subheadings, and author-date entries...

  8. Sensing Passive Eye Response to Impact Induced Head Acceleration Using MEMS IMUs.

    PubMed

    Meng, Yuan; Bottenfield, Brent; Bolding, Mark; Liu, Lei; Adams, Mark L

    2018-02-01

    The eye may act as a surrogate for the brain in response to head acceleration during an impact. Passive eye movements in a dynamic system are sensed by microelectromechanical systems (MEMS) inertial measurement units (IMU) in this paper. The technique is validated using a three-dimensional printed scaled human skull model and on human volunteers by performing drop-and-impact experiments with ribbon-style flexible printed circuit board IMUs inserted in the eyes and reference IMUs on the heads. Data are captured by a microcontroller unit and processed using data fusion. Displacements are thus estimated and match the measured parameters. Relative accelerations and displacements of the eye to the head are computed indicating the influence of the concussion causing impacts.

  9. Temporomandibular disorders, head and orofacial pain: cervical spine considerations.

    PubMed

    Kraus, Steve

    2007-01-01

    Head and orofacial pain originates from dental, neurologic, musculoskeletal, otolaryngologic, vascular, metaplastic, or infectious disease. It is treated by many health care practitioners, such as dentists, oral surgeons, and physicians. The article focuses on the nonpathologic involvement of the musculoskeletal system as a source of head and orofacial pain. The areas of the musculoskeletal system that are reviewed include the temporomandibular joint and muscles of mastication--collectively referred to as temporomandibular disorders (TMDs) and cervical spine disorders. The first part of the article highlights the role of physical therapy in the treatment of TMDs. The second part discusses cervical spine considerations in the management of TMDs and head and orofacial symptoms. It concludes with and overview of the evaluation and treatment of the cervical spine.

  10. Postural compensation for vestibular loss and implications for rehabilitation.

    PubMed

    Horak, Fay B

    2010-01-01

    This chapter summarizes the role of the vestibular system in postural control so that specific and effective rehabilitation can be designed that facilitates compensation for loss of vestibular function. Patients with bilateral or unilateral loss of peripheral vestibular function are exposed to surface perturbations to quantify automatic postural responses. Studies also evaluated the effects of audio- and vibrotactile-biofeedback to improve stability in stance and gait. The most important role of vestibular information for postural control is to control orientation of the head and trunk in space with respect to gravitoinertial forces, particularly when balancing on unstable surfaces. Vestibular sensory references are particularly important for postural control at high frequencies and velocities of self-motion, to reduce trunk drift and variability, to provide an external reference frame for the trunk and head in space; and to uncouple coordination of the trunk from the legs and the head-in-space from the body CoM. The goal of balance rehabilitation for patients with vestibular loss is to help patients 1) use remaining vestibular function, 2) depend upon surface somatosensory information as their primary postural sensory system, 3) learn to use stable visual references, and 4) identify efficient and effective postural movement strategies.

  11. Principle Study of Head Meridian Acupoint Massage to Stress Release via Grey Data Model Analysis.

    PubMed

    Lee, Ya-Ting

    2016-01-01

    This paper presents the scientific study of the effectiveness and action principle of head meridian acupoint massage by applying the grey data model analysis approach. First, the head massage procedure for massaging the important head meridian acupuncture points including Taiyang, Fengfu, Tianzhu, Fengqi, and Jianjing is formulated in a standard manner. Second, the status of the autonomic nervous system of each subject is evaluated by using the heart rate variability analyzer before and after the head massage following four weeks. Afterward, the physiological factors of autonomic nerves are quantitatively analyzed by using the grey data modeling theory. The grey data analysis can point out that the status of autonomic nervous system is greatly improved after the massage. The order change of the grey relationship weighting of physiological factors shows the action principle of the sympathetic and parasympathetic nerves when performing head massage. In other words, the grey data model is able to distinguish the detailed interaction of the autonomic nervous system and the head meridian acupoint massage. Thus, the stress relaxing effect of massaging head meridian acupoints is proved, which is lacked in literature. The results can be a reference principle for massage health care in practice.

  12. Principle Study of Head Meridian Acupoint Massage to Stress Release via Grey Data Model Analysis

    PubMed Central

    Lee, Ya-Ting

    2016-01-01

    This paper presents the scientific study of the effectiveness and action principle of head meridian acupoint massage by applying the grey data model analysis approach. First, the head massage procedure for massaging the important head meridian acupuncture points including Taiyang, Fengfu, Tianzhu, Fengqi, and Jianjing is formulated in a standard manner. Second, the status of the autonomic nervous system of each subject is evaluated by using the heart rate variability analyzer before and after the head massage following four weeks. Afterward, the physiological factors of autonomic nerves are quantitatively analyzed by using the grey data modeling theory. The grey data analysis can point out that the status of autonomic nervous system is greatly improved after the massage. The order change of the grey relationship weighting of physiological factors shows the action principle of the sympathetic and parasympathetic nerves when performing head massage. In other words, the grey data model is able to distinguish the detailed interaction of the autonomic nervous system and the head meridian acupoint massage. Thus, the stress relaxing effect of massaging head meridian acupoints is proved, which is lacked in literature. The results can be a reference principle for massage health care in practice. PMID:26904144

  13. Overview of a Hybrid Underwater Camera System

    DTIC Science & Technology

    2014-07-01

    meters), in increments of 200ps. The camera is also equipped with 6:1 motorized zoom lens. A precision miniature attitude, heading reference system ( AHRS ...LUCIE Control & Power Distribution System AHRS Pulsed LASER Gated Camera -^ Sonar Transducer (b) LUCIE sub-systems Proc. ofSPIEVol. 9111

  14. Reference-based pricing: will other provinces follow the BC lead?

    PubMed

    Mullens, A

    1998-01-27

    REFERENCE-BASED PRICING has had a major impact on medical practice in British Columbia. Anne Mullens discusses the new system's first 2 years. She says physicians outside BC should pay attention, because RBP may be heading their way. It is set to land in Australia next month.

  15. Spatial reference frames of visual, vestibular, and multimodal heading signals in the dorsal subdivision of the medial superior temporal area.

    PubMed

    Fetsch, Christopher R; Wang, Sentao; Gu, Yong; Deangelis, Gregory C; Angelaki, Dora E

    2007-01-17

    Heading perception is a complex task that generally requires the integration of visual and vestibular cues. This sensory integration is complicated by the fact that these two modalities encode motion in distinct spatial reference frames (visual, eye-centered; vestibular, head-centered). Visual and vestibular heading signals converge in the primate dorsal subdivision of the medial superior temporal area (MSTd), a region thought to contribute to heading perception, but the reference frames of these signals remain unknown. We measured the heading tuning of MSTd neurons by presenting optic flow (visual condition), inertial motion (vestibular condition), or a congruent combination of both cues (combined condition). Static eye position was varied from trial to trial to determine the reference frame of tuning (eye-centered, head-centered, or intermediate). We found that tuning for optic flow was predominantly eye-centered, whereas tuning for inertial motion was intermediate but closer to head-centered. Reference frames in the two unimodal conditions were rarely matched in single neurons and uncorrelated across the population. Notably, reference frames in the combined condition varied as a function of the relative strength and spatial congruency of visual and vestibular tuning. This represents the first investigation of spatial reference frames in a naturalistic, multimodal condition in which cues may be integrated to improve perceptual performance. Our results compare favorably with the predictions of a recent neural network model that uses a recurrent architecture to perform optimal cue integration, suggesting that the brain could use a similar computational strategy to integrate sensory signals expressed in distinct frames of reference.

  16. Spatial Updating Strategy Affects the Reference Frame in Path Integration.

    PubMed

    He, Qiliang; McNamara, Timothy P

    2018-06-01

    This study investigated how spatial updating strategies affected the selection of reference frames in path integration. Participants walked an outbound path consisting of three successive waypoints in a featureless environment and then pointed to the first waypoint. We manipulated the alignment of participants' final heading at the end of the outbound path with their initial heading to examine the adopted reference frame. We assumed that the initial heading defined the principal reference direction in an allocentric reference frame. In Experiment 1, participants were instructed to use a configural updating strategy and to monitor the shape of the outbound path while they walked it. Pointing performance was best when the final heading was aligned with the initial heading, indicating the use of an allocentric reference frame. In Experiment 2, participants were instructed to use a continuous updating strategy and to keep track of the location of the first waypoint while walking the outbound path. Pointing performance was equivalent regardless of the alignment between the final and the initial headings, indicating the use of an egocentric reference frame. These results confirmed that people could employ different spatial updating strategies in path integration (Wiener, Berthoz, & Wolbers Experimental Brain Research 208(1) 61-71, 2011), and suggested that these strategies could affect the selection of the reference frame for path integration.

  17. Clinical outcome of head and neck cancer patients: a comparison between ENT patients referred via the 2 weeks wait pathway and alternative routes in the UK health system.

    PubMed

    Wong, B Y Winson; Fischer, S; Cruickshank, H E

    2017-01-01

    2 weeks wait (2ww) referral was intended to improve cancer outcomes in the UK. However, a previous study found that 2ww failed to detect early stage head and neck cancer. There is no current study to examine the survival outcome of head and neck cancer patients diagnosed on 2ww and non-2ww pathways. The aim of this study is to compare the outcome of cancer patients diagnosed on these pathways. We performed a retrospective review of head and neck cancer patients diagnosed between 2009 and 2013 in the ENT Department at Mid-Yorkshire NHS Hospitals Trust. Gender, age, disease staging, treatment modalities, route of referrals along with survival data were documented. Survival analysis was performed for 2ww and non-2ww cancer patients. There were 4123 patients referred on 2ww during the study period. 147 patients were diagnosed with cancers on 2ww and 89 patients were diagnosed on non-2ww. There were no statistical differences in clinical staging (p = 0.416) and overall survival (p = 0.376) between 2ww and non-2ww patients. This study failed to demonstrate a better overall survival in head and neck cancer patients diagnosed on 2ww pathway within the ENT cohort. Current referral system needs to be refined to improve the survival outcome in head and neck cancer patients.

  18. Using Tri-Axial Accelerometers to Assess the Dynamic Control of Head Posture During Gait

    NASA Technical Reports Server (NTRS)

    Lawrence, John H., III

    2003-01-01

    Long duration spaceflight is known to cause a variety of biomedical stressors to the astronaut. One of the more functionally destabilizing effects of spaceflight involves microgravity-induced changes in vestibular or balance control. Balance control requires the integration of the vestibular, visual, and proprioceptive systems. In the microgravity environment, the normal gravity vector present on Earth no longer serves as a reference for the balance control system. Therefore, adaptive changes occur to the vestibular system to affect control of body orientation with altered, or non-present, gravity and/or proprioceptive inputs. Upon return to a gravity environment, the vestibular system must re-incorporate the gravity vector and gravity-induced proprioceptive inputs into the balance control regime. The result is often a period of postural instability, which may also be associated with space motion sickness (oscillopsia, nausea, and vertigo). Previous studies by the JSC Neuroscience group have found that returning astronauts often employ alterations in gait mechanics to maintain postural control during gait. It is believed that these gait alterations are meant to decrease the transfer of heel strike shock energy to the head, thus limiting the contradictory head and eye movements that lead to gait instability and motion sickness symptoms. We analyzed pre- and post-spaceflight tri-axial accelerometer data from the NASA/MIR long duration spaceflight missions to assess the heel to head transfer of heel strike shock energy during locomotion. Up to seven gait sessions (three preflight, four postflight) of head and shank (lower leg) accelerometer data was previously collected from six astronauts who engaged in space flights of four to six months duration. In our analysis, the heel to head transmission of shock energy was compared using peak vertical acceleration (a), peak jerk (j) ratio, and relative kinetic energy (a). A host of generalized movement variables was produced in an effort to isolate those that best highlighted vestibular adaptation due to spaceflight. Data suggest that astronauts used either head or body centered control to reduce the effects of heel strike shock on head position during normal walking at self-selected speeds. Moreover, the form of that control appears to fall under one of two categories: homeostatic or adaptive. Homeostatic control refers to tight constraint (small error) over the value of a given variable before and after spaceflight with little or no adaptive changes. Adaptive control refers to lesser constraint over a given movement variable with clear adaptation to earth gravity upon return from spaceflight. Heel strike shock absorption (ratio of heel to head peak acceleration) best-discriminated head and body centered control strategies. Further, peak jerk data was useful for illustrating pre- and postflight differences in segmental (shank versus head) movement energy. Results from kinetic energy analysis show high consistency between subjects and across test dates. Whether this result highlights a control strategy or is an artifact of approximating body segments using anthropometric tables is, at this point, unclear.

  19. 78 FR 1735 - Airworthiness Directives; Honeywell International Inc. Air Data Pressure Transducers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ... reviewed Honeywell Alert Service Bulletin ADM/ADC/ADAHRS-34-A01, dated November 6, 2012. This service...), air data computers, air data attitude heading reference systems, and digital air data computers... fails. Honeywell Service Bulletin ACM/ADC/ADAHRS-34-A01, dated November 6, 2012, specifies to refer to...

  20. Calibration validation for the new generation runway visual range system

    DOT National Transportation Integrated Search

    2000-07-01

    A forward scattermeter, consisting of transmitter and receiver heads mounted on a fork, is used in the New Genreration Runway Visual Range (NGRVR) System to assess the clarity of the atmosphere. The scattermeter is calibrated by comparison with refer...

  1. Advancements in the U.S. Army Corps of Engineers Hydrographic Survey Capabilities: The SHOALS System

    DTIC Science & Technology

    2016-05-12

    forward direction of the aircraft. The scanner uses feedback from an inertial reference unit , rigidly mounted to the TRS, that measures aircraft roll ...LTN-90 inertial reference unit provides aircraft attitude, including roll , pitch, and heading and vertical accelerations. The unit supports four...Figure 3 The transceiver subsystem. From left to right, receiver optics, receiver electronics, telescope, scanner, and inertial reference unit . The

  2. 14 CFR Appendix F to Part 135 - Airplane Flight Recorder Specification

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Heading (Primary flight crew reference) 0−360° and Discrete “true” or “mag” ±2° 1 0.5° When true or magnetic heading can be selected as the primary heading reference, a discrete indicating selection must be... synchronization reference On-Off (Discrete)None 1 Preferably each crew member but one discrete acceptable for all...

  3. Three-dimensional reproducibility of natural head position.

    PubMed

    Weber, Diana W; Fallis, Drew W; Packer, Mark D

    2013-05-01

    Although natural head position has proven to be reliable in the sagittal plane, with an increasing interest in 3-dimensional craniofacial analysis, a determination of its reproducibility in the coronal and axial planes is essential. This study was designed to evaluate the reproducibility of natural head position over time in the sagittal, coronal, and axial planes of space with 3-dimensional imaging. Three-dimensional photographs were taken of 28 adult volunteers (ages, 18-40 years) in natural head position at 5 times: baseline, 4 hours, 8 hours, 24 hours, and 1 week. Using the true vertical and horizontal laser lines projected in an iCAT cone-beam computed tomography machine (Imaging Sciences International, Hatfield, Pa) for orientation, we recorded references for natural head position on the patient's face with semipermanent markers. By using a 3-dimensional camera system, photographs were taken at each time point to capture the orientation of the reference points. By superimposing each of the 5 photographs on stable anatomic surfaces, changes in the position of the markers were recorded and assessed for parallelism by using 3dMDvultus (3dMD, Atlanta, Ga) and software (Dolphin Imaging & Management Solutions, Chatsworth, Calif). No statistically significant differences were observed between the 5 time points in any of the 3 planes of space. However, a statistically significant difference was observed between the mean angular deviations of 3 reference planes, with a hierarchy of natural head position reproducibility established as coronal > axial > sagittal. Within the parameters of this study, natural head position was found to be reproducible in the sagittal, coronal, and axial planes of space. The coronal plane had the least variation over time, followed by the axial and sagittal planes. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  4. Head circumference growth reference charts of children younger than 7 years in Chinese rural areas.

    PubMed

    Xie, Shengnan; Shi, Junxin; Wang, Jianmin; Li, Neng; Yang, Senbei; Zhang, Jing

    2014-12-01

    The head circumference growth reference charts for children in China are presently based on urban children. However, the references may not apply to rural children because of the differences between urban and rural areas, such as economy, culture, and dietary habits. Our objective was to provide a reliable continuous set of head circumference growth reference charts for male and female children less than 7 years of age in Chinese rural areas. Children in our study were identified by multistage stratified cluster sampling from rural areas of 10 provinces in China. Questionnaire survey and anthropometric measurements were conducted in data collection. Head circumference was measured with a nonelastic tape on a line passing over the glabella and posterior occipital protrusion in children. We compared the fiftieth percentile of our cross-sectional data with the data of Chinese cities, World Health Organization, and the United States. A total of 95,904 children (48,722 boys and 47,182 girls) were included in the study. We present age- and sex-appropriate head circumference growth charts younger than 7 years for Chinese rural areas. The head circumference percentiles of the children in rural China are much smaller than the children in Chinese urban areas, World Health Organization, and the US percentiles after 2 years old. Head circumference percentiles can be applied in growth monitoring, but current head circumference growth references promulgated in urban China may not be suitable for rural areas in China. Providing head circumference growth reference charts for rural Chinese children who are younger than 7 years old is very important. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    PubMed Central

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  6. Development of head injury assessment reference values based on NASA injury modeling.

    PubMed

    Somers, Jeffrey T; Granderson, Bradley; Melvin, John W; Tabiei, Ala; Lawrence, Charles; Feiveson, Alan; Gernhardt, Michael; Ploutz-Snyder, Robert; Patalak, John

    2011-11-01

    NASA is developing a new crewed vehicle and desires a lower risk of injury compared to automotive or commercial aviation. Through an agreement with the National Association of Stock Car Auto Racing, Inc. (NASCAR®), an analysis of NASCAR impacts was performed to develop new injury assessment reference values (IARV) that may be more relevant to NASA's context of vehicle landing operations. Head IARVs associated with race car impacts were investigated by analyzing all NASCAR recorded impact data for the 2002-2008 race seasons. From the 4015 impact files, 274 impacts were selected for numerical simulation using a custom NASCAR restraint system and Hybrid III 50th percentile male Finite Element Model (FEM) in LS-DYNA. Head injury occurred in 27 of the 274 selected impacts, and all of the head injuries were mild concussions with or without brief loss of consciousness. The 247 noninjury impacts selected were representative of the range of crash dynamics present in the total set of impacts. The probability of head injury was estimated for each metric using an ordered probit regression analysis. Four metrics had good correlation with the head injury data: head resultant acceleration, head change in velocity, HIC 15, and HIC 36. For a 5% risk of AIS≥1/AIS≥2 head injuries, the following IARVs were found: 121.3/133.2 G (head resultant acceleration), 20.3/22.0 m/s (head change in velocity), 1,156/1,347 (HIC 15), and 1,152/1,342 (HIC 36) respectively. Based on the results of this study, further analysis of additional datasets is recommended before applying these results to future NASA vehicles.

  7. Head ballistocardiogram based on wireless multi-location sensors.

    PubMed

    Onizuka, Kohei; Sodini, Charles G

    2015-08-01

    Recently a wearable BCG monitoring technique based on an accelerometer worn at the ear was demonstrated to replace a conventional bulky BCG acquisition system. In this work, a multi-location wireless vital signs monitor was developed, and at least two common acceleration vectors correlating to sitting-BCG were found in the supine position by using head PPG signal as a reference for eight healthy human subjects. The head side amplitude in the supine position is roughly proportional to the sitting amplitude that is in turn proportional to the stroke volume. Signal processing techniques to identify J-waves in a subject having small amplitude was also developed based on the two common vectors at the head side and top.

  8. Design and development of a Space Station proximity operations research and development mockup

    NASA Technical Reports Server (NTRS)

    Haines, Richard F.

    1986-01-01

    Proximity operations (Prox-Ops) on-orbit refers to all activities taking place within one km of the Space Station. Designing a Prox-Ops control station calls for a comprehensive systems approach which takes into account structural constraints, orbital dynamics including approach/departure flight paths, myriad human factors and other topics. This paper describes a reconfigurable full-scale mock-up of a Prox-Ops station constructed at Ames incorporating an array of windows (with dynamic star field, target vehicle(s), and head-up symbology), head-down perspective display of manned and unmanned vehicles, voice- actuated 'electronic checklist', computer-generated voice system, expert system (to help diagnose subsystem malfunctions), and other displays and controls. The facility is used for demonstrations of selected Prox-Ops approach scenarios, human factors research (work-load assessment, determining external vision envelope requirements, head-down and head-up symbology design, voice synthesis and recognition research, etc.) and development of engineering design guidelines for future module interiors.

  9. Spatial vision within egocentric and exocentric frames of reference

    NASA Technical Reports Server (NTRS)

    Howard, Ian P.

    1991-01-01

    It is remarkable that we are able to perceive a stable visual world and judge the directions, orientations, and movements of visual objects given that images move on the retina, the eyes move in the head, the head moves on the body, and the body moves in space. An understanding of the mechanisms underlying perceptual stability and spatial judgements requires precise definitions of relevant coordinate systems. An egocentric frame of reference is defined with respect to some part of the observer. There are four principal egocentric frames of reference, a station-point frame associated with the nodal point of the eye, an retinocentric frame associated with the retina, a headcentric frame associated with the head, and a bodycentric frame (torsocentric) associated with the torso. Additional egocentric frames can be identified with respect to any segment of the body. An egocentric task is one in which the position, orientation, or motion of an object is judged with respect to an egocentric frame of reference. A proprioceptive is a special kind of egocentric task in which the object being judged is also part of the body. An example of a proprioceptive task is that of directing the gaze toward the seen or unseen toe. An exocentric frame of reference is external to the observer. Geographical coordinates and the direction of gravity are examples of exocentric frames of reference. These various frames are listed in tabular form, together with examples of judgements of each type.

  10. Head Circumference Charts for Turkish Children Aged Five to Eighteen Years.

    PubMed

    Kara, Bülent; Etiler, Nilay; Aydoğan Uncuoğlu, Ayşen; Maraş Genç, Hülya; Ulak Gümüşlü, Esen; Gökçay, Gülbin; Furman, Andrezej

    2016-03-01

    Most head circumference growth references are useful during the first years of life, but they are also useful for older children when screening for developmental, neurological, and genetic disorders. We aimed to develop head circumference growth reference charts for age, height, and waist circumference for Turkish children aged 5-18 years. Head circumference, height, and waist circumference measurements were obtained from 5079 students aged 5-18 years from İzmit, Kocaeli Province, Turkey. The LMS method was used to construct reference centile curves. Head circumference measurements were strongly correlated with height (r=0.74), weight (r=0.76), and waist circumference (r=0.68). The mean head circumference values for boys were larger than those for girls at all ages. Compared with data from the United States, the World Health Organization, and other studies from Turkey, our data showed a decrease in head circumference at all ages for both sexes. Local growth charts can be used to evaluate head circumference growth in older Turkish children and adolescents.

  11. Fire Protection for Libraries.

    ERIC Educational Resources Information Center

    Fortson-James, Judith

    1981-01-01

    This overview of preventive measures that can be taken to help minimize damage to library materials from fire discusses the advantages, disadvantages, dangers, and comparative costs of several types of sprinkler systems, including high-expansion foam, total-flooding, dry- and wet-pipe systems, and on-off sprinkler heads. Five references are…

  12. Spatial Reorientation of Sensorimotor Balance Control in Altered Gravity

    NASA Technical Reports Server (NTRS)

    Paloski, W. H.; Black, F. L.; Kaufman, G. D.; Reschke, M. F.; Wood, S. J.

    2007-01-01

    Sensorimotor coordination of body segments following space flight are more pronounced after landing when the head is actively tilted with respect to the trunk. This suggests that central vestibular processing shifts from a gravitational frame of reference to a head frame of reference in microgravity. A major effect of such changes is a significant postural instability documented by standard head-erect Sensory Organization Tests. Decrements in functional performance may still be underestimated when head and gravity reference frames remained aligned. The purpose of this study was to examine adaptive changes in spatial processing for balance control following space flight by incorporating static and dynamic tilts that dissociate head and gravity reference frames. A second aim of this study was to examine the feasibility of altering the re-adaptation process following space flight by providing discordant visual-vestibular-somatosensory stimuli using short-radius pitch centrifugation.

  13. 46 CFR 154.1 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and Engineering Systems, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE... Institute 11 West 42nd Street, New York, NY 10036 ANSI Z89.1-69 Safety Requirements for Industrial Head...

  14. The Use of Magnetoencephalography in Evaluating Human Performance

    DTIC Science & Technology

    1991-06-01

    determines the head cartesian coordinate system, and calculates the locations of the dipole sets in this reference frame. This system is based on an optical ...differences in brain activity are found between imagers and nonimagers , the brain areas which seem to be involved will be localized. 25 3. The poor

  15. 46 CFR 151.05-1 - Explanation of column headings in Table 151.05.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cargo by the temperature of the cargo during transit. (1) Ambient temperature. Cargo which is carried at... engineering) of this chapter. (p) Temperature control installations. This column refers to systems which are...

  16. TWO-PHASE (GAS-LIQUID) SYSTEM: HEAT TRANSFER AND HYDRAULICS. An Annotated Bibliography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kepple, R.R.; Tung, T.V.

    1963-07-01

    A bibliography of 2843 references in abstracted form is presented which covers the period l950 to 1962. The references are arranged under the following headings: books and review articles, boiling, bubble, condensation, evaporation, equations of state, interfacial characteristics, mass transfer across phase boundaries, measurement techniques, nuclear reactor heat removal, and twophase flow. An author index is included. (D.L.C.)

  17. Head Circumference Charts for Turkish Children Aged Five to Eighteen Years

    PubMed Central

    KARA, Bülent; ETİLER, Nilay; AYDOĞAN UNCUOĞLU, Ayşen; MARAŞ GENÇ, Hülya; ULAK GÜMÜŞLÜ, Esen; GÖKÇAY, Gülbin; FURMAN, Andrezej

    2016-01-01

    Introduction Most head circumference growth references are useful during the first years of life, but they are also useful for older children when screening for developmental, neurological, and genetic disorders. We aimed to develop head circumference growth reference charts for age, height, and waist circumference for Turkish children aged 5–18 years. Methods Head circumference, height, and waist circumference measurements were obtained from 5079 students aged 5–18 years from İzmit, Kocaeli Province, Turkey. The LMS method was used to construct reference centile curves. Results Head circumference measurements were strongly correlated with height (r=0.74), weight (r=0.76), and waist circumference (r=0.68). The mean head circumference values for boys were larger than those for girls at all ages. Compared with data from the United States, the World Health Organization, and other studies from Turkey, our data showed a decrease in head circumference at all ages for both sexes. Conclusion Local growth charts can be used to evaluate head circumference growth in older Turkish children and adolescents. PMID:28360767

  18. Are Two Heads Better than One? System School Leadership Explained and Critiqued

    ERIC Educational Resources Information Center

    Simon, Catherine A.

    2015-01-01

    "System leadership", as applied to the running of schools, refers to a form of leadership that extends beyond a single institution, where headteachers work with establishments other than their own. This approach is predicated on certain beliefs about the role and purpose of collaborative school leadership and management in a marketised…

  19. Updating of visual orientation in a gravity-based reference frame.

    PubMed

    Niehof, Nynke; Tramper, Julian J; Doeller, Christian F; Medendorp, W Pieter

    2017-10-01

    The brain can use multiple reference frames to code line orientation, including head-, object-, and gravity-centered references. If these frames change orientation, their representations must be updated to keep register with actual line orientation. We tested this internal updating during head rotation in roll, exploiting the rod-and-frame effect: The illusory tilt of a vertical line surrounded by a tilted visual frame. If line orientation is stored relative to gravity, these distortions should also affect the updating process. Alternatively, if coding is head- or frame-centered, updating errors should be related to the changes in their orientation. Ten subjects were instructed to memorize the orientation of a briefly flashed line, surrounded by a tilted visual frame, then rotate their head, and subsequently judge the orientation of a second line relative to the memorized first while the frame was upright. Results showed that updating errors were mostly related to the amount of subjective distortion of gravity at both the initial and final head orientation, rather than to the amount of intervening head rotation. In some subjects, a smaller part of the updating error was also related to the change of visual frame orientation. We conclude that the brain relies primarily on a gravity-based reference to remember line orientation during head roll.

  20. Development of Head Injury Assessment Reference Values Based on NASA Injury Modeling

    NASA Technical Reports Server (NTRS)

    Somers, Jeffrey T.; Melvin, John W.; Tabiei, Ala; Lawrence, Charles; Ploutz-Snyder, Robert; Granderson, Bradley; Feiveson, Alan; Gernhardt, Michael; Patalak, John

    2011-01-01

    NASA is developing a new capsule-based, crewed vehicle that will land in the ocean, and the space agency desires to reduce the risk of injury from impact during these landings. Because landing impact occurs for each flight and the crew might need to perform egress tasks, current injury assessment reference values (IARV) were deemed insufficient. Because NASCAR occupant restraint systems are more effective than the systems used to determine the current IARVs and are similar to NASA s proposed restraint system, an analysis of NASCAR impacts was performed to develop new IARVs that may be more relevant to NASA s context of vehicle landing operations. Head IARVs associated with race car impacts were investigated by completing a detailed analysis of all of the 2002-2008 NASCAR impact data. Specific inclusion and exclusion criteria were used to select 4071 impacts from the 4015 recorder files provided (each file could contain multiple impact events). Of the 4071 accepted impacts, 274 were selected for numerical simulation using a custom NASCAR restraint system and Humanetics Hybrid-III 50th percentile numerical dummy model in LS-DYNA. Injury had occurred in 32 of the 274 selected impacts, and 27 of those injuries involved the head. A majority of the head injuries were mild concussions with or without brief loss of consciousness. The 242 non-injury impacts were randomly selected and representative of the range of crash dynamics present in the total set of 4071 impacts. Head dynamics data (head translational acceleration, translational change in velocity, rotational acceleration, rotational velocity, HIC-15, HIC-36, and the Head 3ms clip) were filtered according to SAE J211 specifications and then transformed to a log scale. The probability of head injury was estimated using a separate logistic regression analysis for each log-transformed predictor candidate. Using the log transformation constrains the estimated probability of injury to become negligible as IARVs approach zero. For the parameters head translational acceleration, head translational velocity change, head rotational acceleration, HIC-15, and HIC-36, conservative values (in the lower 95% confidence interval) that gave rise to a 5% risk of any injury occurring were estimated as 40.0 G, 7.9 m/s, 2200 rad/s2, 98.4, and 77.4 respectively. Because NASA is interested in the consequence of any particular injury on the ability of the crew to perform egress tasks, the head injuries that occurred in the NASCAR dataset were classified according to a NASA-developed scale (Classes I - III) for operationally relevant injuries, which classifies injuries on the basis of their operational significance. Additional analysis of the data was performed to determine the probability of each injury class occurring, and this was estimated using an ordered probit model. For head translational acceleration, head translational velocity change, head rotational acceleration, head rotational velocity, HIC-36, and head 3ms clip, conservative values of IARVs that produced a 5% risk of Class II injury were estimated as 50.7 G, 9.5 m/s, 2863 rad/s2, 11.0 rad/s, 30.3, and 46.4 G respectively. The results indicate that head IARVs developed from the NASCAR dataset may be useful to protect crews during landing impact.

  1. A Strategy to Overcome the Radiology Lottery in the Staging of Head and Neck Cancer: An Aid to Attaining the 30-Day Rule

    PubMed Central

    Elloy, Marianne; Jarvis, Sara; Davis, Anne

    2009-01-01

    INTRODUCTION Rapid access to radiological services is essential, if the British Association of Otolaryngologists – Head and Neck Surgeons Minimum Temporal Standards are to be met in the management of head and neck cancer patients. This study assesses a new initiative whereby the multidisciplinary team prioritises allocated imaging appointments rather than using the traditional radiological triage system. PATIENTS AND METHODS This study was a prospective audit of all patients referred over a 3-month period with suspected head and neck cancer. The main outcome measures were: (i) median interval in days from general practitioner (GP) referral to staging scan; and (ii) median interval in days from first clinic appointment to staging scan. RESULTS The new multidisciplinary team booking system led to a statistically significant reduction in the ‘request-to-scan time’ (from 12 days to 5 days). The time from ‘GP to scan’ also improved. CONCLUSIONS This new multidisciplinary team-led booking system, could, in the future, speed up access to radiology services lead and neck cancer patients, allowing earlier definitive treatment. PMID:19126338

  2. Binaural auralization and perceptual verdicality

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.

    1992-01-01

    Early reflection patterns calculated from a room design program were filtered with measured head-related transfer functions (HRTFs) within a 'hypothetical auralization system.' With reference to a particular set of room/listener/sound source configurations, the system is shown to produce both perceptible and imperceptible results. The results of this exploratory analysis are illuminating for future design considerations of HRTF-based auralization systems.

  3. Energy: An annotated selected bibliography

    NASA Technical Reports Server (NTRS)

    Blow, S. J. (Compiler); Peacock, R. W. (Compiler); Sholy, J. J. (Compiler)

    1979-01-01

    This updated bibliography contains approximately 7,000 selected references on energy and energy related topics from bibliographic and other data sources from June 1977. Under each subject heading the entries are arranged by the data, with the latest works first. Subject headings include: resources supply/demand, and forecasting; policy, legislation, and regulation; environment; consumption, conservation, and economics; analysis, systems, and modeling, and information sources and documentation. Fossil fuels, hydrogen and other fuels, liquid/solid wastes and biomass, waste heat utilization, and nuclear power sources are also included.

  4. A Theatre Movement Bibliography, 1978 Edition.

    ERIC Educational Resources Information Center

    Norris, Lynne

    Reference materials that deal with various aspects of theater movement are grouped in this partially annotated bibliography under the following headings: anatomy, kinesiology, and physiology; combat and martial arts; integrated approaches to movement; mime; miscellaneous acting and movement approaches; movement notations systems; movement…

  5. Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

    PubMed

    Pavlovčič, Urban; Diaci, Janez; Možina, Janez; Jezeršek, Matija

    2013-09-26

    Knowing the orientation of the head is important in many fields, including medicine. Many methods and measuring systems exist, but usually they use different markers or sensors attached to the subject's head for head orientation determination. In certain applications these attachments may represent a burden or a distraction to the subject under study which may have an unfavourable impact on the measurement. We propose a non-contact optical method for head-to-trunk orientation measurement that does not require any attachments to the subject under study. An innovative handheld 3D apparatus has been developed for non-invasive and fast 3D shape measurements. It is based on the triangulation principle in combination with fringe projection. The shape of the subject's upper trunk and head is reconstructed from a single image using the Fourier transform profilometry method. Two shape measurements are required to determine the head-to-trunk orientation angles: one in the reference (neutral) position and the other one in the position of interest. The algorithm for the head-to-trunk orientation angle extraction is based on the separate alignment of the shape of the subject's upper trunk and head against the corresponding shape in the reference pose. Single factor analysis of variance (ANOVA) was used for statistical characterisation of the method precision. The method and the 3D apparatus were verified in-vitro using a mannequin and a reference orientation tracker. The uncertainty of the calculated orientation was 2°. During the in-vivo test with a human subject diagnosed with cervical dystonia (aged 60), the repeatability of the measurements was 3°. In-vitro and in-vivo comparison was done on the basis of an experiment with the mannequin and a healthy male (aged 29). These results show that only the difference between flexion/extension measured angles was statistically significant. The differences between means were less than 1° for all ranges. The new non-contact method enables the compensation of the movement of the measuring instrument or the subject's body as a whole, is non-invasive, requires little additional equipment and causes little stress for the subject and operator. We find that it is appropriate for measurements of the head orientation with respect to the trunk for the characterization of the cervical dystonia.

  6. Electromagnetic field generated in model of human head by simplified telephone transceiver

    NASA Astrophysics Data System (ADS)

    King, Ronold W. P.

    1995-01-01

    Possible adverse effects of electromagnetic fields on the human body and especially on the nervous system and the brain are of increasing concern, particularly with reference to cellular telephone transceivers held close to the head. An essential step in the study of this problem is the accurate determination of the complete electromagnetic field penetrating through the skull into the brain. Simple analytical formulas are derived from the theory of the horizontal electric dipole over a layered region. These give the components of the electric and magnetic fields on the air-head surface, in the skin-skull layer, and throughout the brain in terms of a planar model with the dimensions and average electrical properties of the human head. The specific absorption rate (SAR) is also determined.

  7. Catalogue of tooth brush head designs.

    PubMed

    Voelker, Marsha A; Bayne, Stephen C; Liu, Ying; Walker, Mary P

    2013-06-01

    Manual toothbrushes (MTBs) and power toothbrushes (PTBs) are effective oral physiotherapy aids for plaque removal. End-rounded bristles are safer and reduce damage to oral tissues. Nylon bristles are more effective in plaque removal because the bristle is stiffer than natural bristles. In the last 10 years the number of options for MTBs and PTBs has expanded significantly and there is very little information providing a reference frame for the design characteristics of the heads. The present in vitro study characterized a variety of MTB and PTB heads to provide a reference library for other research comparisons which might be made. Various commercial MTB and PTB heads were used to characterize the following: bristle size, shape, diameter, number of tufts, number of bristles per tuft and surface characteristics. Photographs were collected from the side, at 45 degrees and the top of each toothbrush (TB) head using a scanning electron microscope and digital camera. Images were analyzed (Soft Imaging System) for bristle features and designs. One-way ANOVA (p ≤ 0.05) was performed to detect differences among TB types within MTB and PTB groups and between pooled values for MTB and PTB groups. There were significant differences (p ≤ 0.05) in toothbrush bristle diameter and bristle shape. In contrast, there were no significant differences between PTB vs. MTB in regards to bristle diameter, bristle count and tuft count. The results suggest that although there are wide variations in toothbrush head designs, significant differences were found only in relation to bristle diameter and shape.

  8. Measuring mandibular motions

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Rositano, S.; Taylor, R. C.

    1977-01-01

    Mandibular motion along three axes is measured by three motion transducers on floating yoke that rests against mandible. System includes electronics to provide variety of outputs for data display and processing. Head frame is strapped to test subject's skull to provide fixed point of reference for transducers.

  9. Low-head sea lamprey barrier effects on stream habitat and fish communities in the Great Lakes basin

    USGS Publications Warehouse

    Dodd, H.R.; Hayes, D.B.; Baylis, J.R.; Carl, L.M.; Goldstein, J.D.; McLaughlin, R.L.; Noakes, D.L.G.; Porto, L.M.; Jones, M.L.

    2003-01-01

    Low-head barriers are used to block adult sea lamprey (Petromyzon marinus) from upstream spawning habitat. However, these barriers may impact stream fish communities through restriction of fish movement and habitat alteration. During the summer of 1996, the fish community and habitat conditions in twenty-four stream pairs were sampled across the Great Lakes basin. Seven of these stream pairs were re-sampled in 1997. Each pair consisted of a barrier stream with a low-head barrier and a reference stream without a low-head barrier. On average, barrier streams were significantly deeper (df = 179, P = 0.0018) and wider (df = 179, P = 0.0236) than reference streams, but temperature and substrate were similar (df = 183, P = 0.9027; df = 179, P = 0.999). Barrier streams contained approximately four more fish species on average than reference streams. However, streams with low-head barriers showed a greater upstream decline in species richness compared to reference streams with a net loss of 2.4 species. Barrier streams also showed a peak in richness directly downstream of the barriers, indicating that these barriers block fish movement upstream. Using S??renson's similarity index (based on presence/absence), a comparison of fish community assemblages above and below low-head barriers was not significantly different than upstream and downstream sites on reference streams (n = 96, P > 0.05), implying they have relatively little effect on overall fish assemblage composition. Differences in the frequency of occurrence and abundance between barrier and reference streams was apparent for some species, suggesting their sensitivity to barriers.

  10. At what age is hydrocephalus detected, and what is the role of head circumference measurements?

    PubMed

    Breuning-Broers, Jacqueline M; Deurloo, Jacqueline A; Gooskens, Rob H; Verkerk, Paul H

    2014-02-01

    To investigate at what age hydrocephalus is detected and to assess the role of head circumference measurements in detecting hydrocephalus, we performed a retrospective chart review in children with hydrocephalus treated in a tertiary paediatric hospital in the Netherlands. The study group contained 146 patients; 38 patients (31%) were referred because of abnormalities in head circumference. Eighty-nine per cent of the patients were detected in the first year of life. After this period, no patients were referred because of an abnormal head circumference. Therefore, head circumference measurements seem to have little value for detecting hydrocephalus after the first year of life.

  11. Modified method of recording and reproducing natural head position with a multicamera system and a laser level.

    PubMed

    Liu, Xiao-jing; Li, Qian-qian; Pang, Yuan-jie; Tian, Kai-yue; Xie, Zheng; Li, Zi-li

    2015-06-01

    As computer-assisted surgical design becomes increasingly popular in maxillofacial surgery, recording patients' natural head position (NHP) and reproducing it in the virtual environment are vital for preoperative design and postoperative evaluation. Our objective was to test the repeatability and accuracy of recording NHP using a multicamera system and a laser level. A laser level was used to project a horizontal reference line on a physical model, and a 3-dimensional image was obtained using a multicamera system. In surgical simulation software, the recorded NHP was reproduced in the virtual head position by registering the coordinate axes with the horizontal reference on both the frontal and lateral views. The repeatability and accuracy of the method were assessed using a gyroscopic procedure as the gold standard. The interclass correlation coefficients for pitch and roll were 0.982 (0.966, 0.991) and 0.995 (0.992, 0.998), respectively, indicating a high degree of repeatability. Regarding accuracy, the lack of agreement in orientation between the new method and the gold standard was within the ranges for pitch (-0.69°, 1.71°) and for roll (-0.92°, 1.20°); these have no clinical significance. This method of recording and reproducing NHP with a multicamera system and a laser level is repeatable, accurate, and clinically feasible. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  12. MEASUREMENT OF MOTION CORRECTED WIND VELOCITY USING AN AEROSTAT LOFTED SONIC ANEMOMETER

    EPA Science Inventory

    An aerostat-lofted, sonic anemometer was used to determine instantaneous 3 dimensional wind velocities at altitudes relevant to fire plume dispersion modeling. An integrated GPS, inertial measurement unit, and attitude heading and reference system corrected the wind data for th...

  13. Autonomous Observations of the Upper Ocean Stratification and Velocity Fields About the Seasonally-Retreating Marginal Ice Zone

    DTIC Science & Technology

    2013-09-30

    Unit and Attitude Heading Reference System (IMU/ AHRS ). The former was motivated by analysis of prototype data that suggested that vortex shedding from...relative orientation of the coordinate system of the VN-100 IMU/ AHRS (mounted on a board inside the ITP-V pressure case) relative to that of the ACM

  14. Characterization of Vertical Impact Device Acceleration Pulses Using Parametric Assessment: Phase I

    DTIC Science & Technology

    2015-04-01

    vehicle seating systems. Previous research on the VID (Knox, T., Pellettiere, J., Perry, C., Plaga , J., Bonfeld, J., 2008; Veridian Contract Report...BIBLIOGRAPHY/REFERENCES Knox, T., Pellettiere, J., Perry, C., Plaga , J., Bonfeld, J. (2008). New Sensors to Track Head Acceleration During Possible

  15. Longitudinal diffusion MRI for treatment response assessment: Preliminary experience using an MRI-guided tri-cobalt 60 radiotherapy system.

    PubMed

    Yang, Yingli; Cao, Minsong; Sheng, Ke; Gao, Yu; Chen, Allen; Kamrava, Mitch; Lee, Percy; Agazaryan, Nzhde; Lamb, James; Thomas, David; Low, Daniel; Hu, Peng

    2016-03-01

    To demonstrate the preliminary feasibility of a longitudinal diffusion magnetic resonance imaging (MRI) strategy for assessing patient response to radiotherapy at 0.35 T using an MRI-guided radiotherapy system (ViewRay). Six patients (three head and neck cancer, three sarcoma) who underwent fractionated radiotherapy were enrolled in this study. A 2D multislice spin echo single-shot echo planar imaging diffusion pulse sequence was implemented on the ViewRay system and tested in phantom studies. The same pulse sequence was used to acquire longitudinal diffusion data (every 2-5 fractions) on the six patients throughout the entire course of radiotherapy. The reproducibility of the apparent diffusion coefficient (ADC) measurements was assessed using reference regions and the temporal variations of the tumor ADC values were evaluated. In diffusion phantom studies, the ADC values measured on the ViewRay system matched well with reference ADC values with <5% error for a range of ground truth diffusion coefficients of 0.4-1.1 × 10(-3) mm(2)/s. The remote reference regions (i.e., brainstem in head and neck patients) had consistent ADC values throughout the therapy for all three head and neck patients, indicating acceptable reproducibility of the diffusion imaging sequence. The tumor ADC values changed throughout therapy, with the change differing between patients, ranging from a 40% drop in ADC within the first week of therapy to gradually increasing throughout therapy. For larger tumors, intratumoral heterogeneity was observed. For one sarcoma patient, postradiotherapy biopsy showed less than 10% necrosis score, which correlated with the observed 40% decrease in ADC from the fifth fraction to the eighth treatment fraction. This pilot study demonstrated that longitudinal diffusion MRI is feasible using the 0.35 T ViewRay MRI. Larger patient cohort studies are warranted to correlate the longitudinal diffusion measurements to patient outcomes. Such an approach may enable response-guided adaptive radiotherapy.

  16. Growth chart

    MedlinePlus

    ... while standing up in children over age 3) Head circumference , a measurement of the head size taken by ... carefully. Alternative Names Height and weight chart Images Head circumference Height/weight chart References Cooke DW, Dival SA, ...

  17. Stabilization and mobility of the head and trunk in wild monkeys during terrestrial and flat-surface walks and gallops.

    PubMed

    Dunbar, Donald C; Badam, Gyani L; Hallgrímsson, Benedikt; Vieilledent, Stéphane

    2004-02-01

    This study investigated the patterns of rotational mobility (> or =20 degrees ) and stability (< or =20 degrees ) of the head and trunk in wild Indian monkeys during natural locomotion on the ground and on the flat-topped surfaces of walls. Adult hanuman langurs (Semnopithecus entellus) and bonnet macaques (Macaca radiata) of either gender were cine filmed in lateral view. Whole-body horizontal linear displacement, head and trunk pitch displacement relative to space (earth horizontal), and vertical head displacement were measured from the cine films. Head-to-trunk pitch angle was calculated from the head-to-space and trunk-to-space measurements. Locomotor velocities, cycle durations, angular segmental velocities, mean segmental positions and mean peak frequencies of vertical and angular head displacements were then calculated from the displacement data. Yaw rotations were observed qualitatively. During quadrupedal walks by both species, the head was free to rotate in the pitch and yaw planes on a stabilized trunk. By contrast, during quadrupedal gallops by both species, the trunk pitched on a stabilized head. During both gaits in both species, head and trunk pitch rotations were symmetrical about comparable mean positions in both gaits, with mean head position aligning the horizontal semicircular canals near earth horizontal. Head pitch direction countered head vertical displacement direction to varying degrees during walks and only intermittently during gallops, providing evidence that correctional head pitch rotations are not essential for gaze stabilization. Head-to-space pitch velocities were below 350 deg. s(-1), the threshold above which, at least among humans, the vestibulo-ocular reflex (VOR) becomes saturated. Mean peak frequencies of vertical translations and pitch rotations of the head ranged from 1 Hz to 2 Hz, a lower frequency range than that in which inertia is predicted to be the major stabilizer of the head in these species. Some variables, which were common to both walks and gallops in both species, are likely to reflect constraints in sensorimotor control. Other variables, which differed between the two gaits in both species, are likely to reflect kinematic differences, whereas variables that differed between the two species are attributed primarily to morphological and behavioural differences. It is concluded that either the head or the trunk can provide the nervous system with a reference frame for spatial orientation and that the segment providing that reference can change, depending upon the kinematic characteristics of the chosen gait.

  18. A portable multi-channel recording system for analysis of acceleration and angular velocity in six dimension.

    PubMed

    Yamashita, M; Yamashita, A; Ishii, T; Naruo, Y; Nagatomo, M

    1998-11-01

    A portable recording system was developed for analysis of more than three analog signals collected in field works. Stereo audio recorder, available as consumer products, was made use for a core cornponent of the system. For the two tracks of recording, a multiplexed analog signal is stored on one track, and reference code on the other track. The reference code indicates the start of one cycle for multiplexing and swiching point of each channel. Multiplexed signal is playbacked and decoded with a reference of the code to reconstruct original profiles of the signal. Since commercial stereo recorders have cut DC component off, a fixed reference voltage is inserted in the sequence of multiplexing. Change of voltage at switching from the reference to the data channel is measured from playbacked signal to get the original data with its DC component. Movement of vehicles and human head were analyzed by the system. It was verified to be capable to record and analyze multi-channel signal at a sampling rate more than 10Hz.

  19. Head-on collision of ring dark solitons in Bose Einstein condensates

    NASA Astrophysics Data System (ADS)

    Xue, Ju-Kui; Peng, Ping

    2006-06-01

    The ring dark solitons and their head-on collisions in a Bose-Einstein condensates with thin disc-shaped potential are studied. It is shown that the system admits a solution with two concentric ring solitons, one moving inwards and the other moving outwards, which in small-amplitude limit, are described by the two cylindrical KdV equations in the respective reference frames. By using the extended Poincaré-Lighthill-Kuo perturbation method, the analytical phase shifts following the head-on collisions between two ring dark solitary waves are derived. It is shown that the phase shifts decrease with the radial coordinate r according to the r-1/3 law and depend on the initial soliton amplitude and radius.

  20. Two Dimensional Positioning and Heading Solution for Flying Vehicles using a Line-Scanning Laser Radar (LADAR)

    DTIC Science & Technology

    2011-03-24

    6 2.4.1 Reference Frames . . . . . . . . . . . . . . . . . 6 2.4.2 Line and Feature Extraction . . . . . . . . . . . 7 2.4.3 SLAM ...Positioning System . . . . . . . . . . . . . . . . . . 1 LADAR Laser Radar . . . . . . . . . . . . . . . . . . . . . . . . . . 1 LiDAR Light Detection and...Ranging . . . . . . . . . . . . . . . . 2 SLAM Simultaneous Localization and Mapping . . . . . . . . . . 2 ANT Advanced Navigation Technology

  1. Inertial processing of vestibulo-ocular signals

    NASA Technical Reports Server (NTRS)

    Hess, B. J.; Angelaki, D. E.

    1999-01-01

    New evidence for a central resolution of gravito-inertial signals has been recently obtained by analyzing the properties of the vestibulo-ocular reflex (VOR) in response to combined lateral translations and roll tilts of the head. It is found that the VOR generates robust compensatory horizontal eye movements independent of whether or not the interaural translatory acceleration component is canceled out by a gravitational acceleration component due to simultaneous roll-tilt. This response property of the VOR depends on functional semicircular canals, suggesting that the brain uses both otolith and semicircular canal signals to estimate head motion relative to inertial space. Vestibular information about dynamic head attitude relative to gravity is the basis for computing head (and body) angular velocity relative to inertial space. Available evidence suggests that the inertial vestibular system controls both head attitude and velocity with respect to a gravity-centered reference frame. The basic computational principles underlying the inertial processing of otolith and semicircular canal afferent signals are outlined.

  2. Temporomandibular disorders: referred cranio-cervico-facial clinic.

    PubMed

    Ramírez, Luis Miguel; Sandoval, German Pablo; Ballesteros, Luis Ernesto

    2005-04-01

    The bond between temporomandibular disorders and referred craniofacial symptomatology is more and more evident. In it subsists the prevailing necessity of understanding the temporomandibular disorders and the cranio-cervico-facial referred symptomatology from a neurophysiologic and muscle-skeletal perspective contained in the stomatognatic system. Diagnosis in head and neck areas is difficult because of its complex anatomy. Some painful craniofacial syndromes exhibit the same symptoms although they don.t seem objectively possible and that is what confuses the specialist and the patient. Pain in the head and the neck is one of the most complex to diagnose because of its varied origins that can be neurological, vascular, muscular, ligamental and bony. This article seeks to show some reasonable anatomical and pathophysiological connections of this muscle-skeletal disorder expressed with symptoms like tinnitus, otic fullness, otalgia and migraine among others. Disciplines in health such as neurology, the otolaryngology and dentistry share common anatomical and pathophysiological roads constructed in an increased muscular activity that generates muscle-skeletal disorders and is difficult to locate referred craniofacial symptomatology. This revision aspires to sensitize the medical specialist and the odontologist in the understanding of the important interdisciplinary handling in the detection of this disorder. This offers better tools in the conservative therapy phase of this craniofacial referred symptomatology.

  3. 49 CFR 572.142 - Head assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Head assembly and test procedure. 572.142 Section...-year-Old Child Crash Test Dummy, Alpha Version § 572.142 Head assembly and test procedure. (a) The head assembly (refer to § 572.140(a)(1)(i)) for this test consists of the head (drawing 210-1000), adapter plate...

  4. 49 CFR 572.132 - Head assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Head assembly and test procedure. 572.132 Section... Hybrid III 5th Percentile Female Test Dummy, Alpha Version § 572.132 Head assembly and test procedure. (a) The head assembly (refer to § 572.130(a)(1)(i)) for this test consists of the complete head (drawing...

  5. 49 CFR 572.142 - Head assembly and test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Head assembly and test procedure. 572.142 Section...-year-Old Child Crash Test Dummy, Alpha Version § 572.142 Head assembly and test procedure. (a) The head assembly (refer to § 572.140(a)(1)(i)) for this test consists of the head (drawing 210-1000), adapter plate...

  6. 49 CFR 572.132 - Head assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Head assembly and test procedure. 572.132 Section... Hybrid III 5th Percentile Female Test Dummy, Alpha Version § 572.132 Head assembly and test procedure. (a) The head assembly (refer to § 572.130(a)(1)(i)) for this test consists of the complete head (drawing...

  7. 49 CFR 572.142 - Head assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Head assembly and test procedure. 572.142 Section...-year-Old Child Crash Test Dummy, Alpha Version § 572.142 Head assembly and test procedure. (a) The head assembly (refer to § 572.140(a)(1)(i)) for this test consists of the head (drawing 210-1000), adapter plate...

  8. 49 CFR 572.132 - Head assembly and test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Head assembly and test procedure. 572.132 Section... Hybrid III 5th Percentile Female Test Dummy, Alpha Version § 572.132 Head assembly and test procedure. (a) The head assembly (refer to § 572.130(a)(1)(i)) for this test consists of the complete head (drawing...

  9. 49 CFR 572.132 - Head assembly and test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Head assembly and test procedure. 572.132 Section... Hybrid III 5th Percentile Female Test Dummy, Alpha Version § 572.132 Head assembly and test procedure. (a) The head assembly (refer to § 572.130(a)(1)(i)) for this test consists of the complete head (drawing...

  10. 49 CFR 572.142 - Head assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Head assembly and test procedure. 572.142 Section...-year-Old Child Crash Test Dummy, Alpha Version § 572.142 Head assembly and test procedure. (a) The head assembly (refer to § 572.140(a)(1)(i)) for this test consists of the head (drawing 210-1000), adapter plate...

  11. 49 CFR 572.132 - Head assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Head assembly and test procedure. 572.132 Section... Hybrid III 5th Percentile Female Test Dummy, Alpha Version § 572.132 Head assembly and test procedure. (a) The head assembly (refer to § 572.130(a)(1)(i)) for this test consists of the complete head (drawing...

  12. A study to evaluate STS heads-up ascent trajectory performance employing a minimum-Hamiltonian optimization strategy

    NASA Technical Reports Server (NTRS)

    Sinha, Sujit

    1988-01-01

    A study was conducted to evaluate the performance implications of a heads-up ascent flight design for the Space Transportation System, as compared to the current heads-down flight mode. The procedure involved the use of the Minimum Hamiltonian Ascent Shuttle Trajectory Evaluation Program, which is a three-degree-of-freedom moment balance simulation of shuttle ascent. A minimum-Hamiltonian optimization strategy was employed to maximize injection weight as a function of maximum dynamic pressure constraint and Solid Rocket Motor burnrate. Performance Reference Mission Four trajectory groundrules were used for consistency. The major conclusions are that for heads-up ascent and a mission nominal design maximum dynamic pressure value of 680 psf, the optimum solid motor burnrate is 0.394 ips, which produces a performance enhancement of 4293 lbm relative to the baseline heads-down ascent, with 0.368 ips burnrate solid motors and a 680 psf dynamic pressure constraint. However, no performance advantage exists for heads-up flight if the current Solid Rocket Motor target burnrate of 0.368 ips is used. The advantage of heads-up ascent flight employing the current burnrate is that Space Shuttle Main Engine throttling for dynamic pressure control is not necessary.

  13. In Vivo Evaluation of Wearable Head Impact Sensors.

    PubMed

    Wu, Lyndia C; Nangia, Vaibhav; Bui, Kevin; Hammoor, Bradley; Kurt, Mehmet; Hernandez, Fidel; Kuo, Calvin; Camarillo, David B

    2016-04-01

    Inertial sensors are commonly used to measure human head motion. Some sensors have been tested with dummy or cadaver experiments with mixed results, and methods to evaluate sensors in vivo are lacking. Here we present an in vivo method using high speed video to test teeth-mounted (mouthguard), soft tissue-mounted (skin patch), and headgear-mounted (skull cap) sensors during 6-13 g sagittal soccer head impacts. Sensor coupling to the skull was quantified by displacement from an ear-canal reference. Mouthguard displacements were within video measurement error (<1 mm), while the skin patch and skull cap displaced up to 4 and 13 mm from the ear-canal reference, respectively. We used the mouthguard, which had the least displacement from skull, as the reference to assess 6-degree-of-freedom skin patch and skull cap measurements. Linear and rotational acceleration magnitudes were over-predicted by both the skin patch (with 120% NRMS error for a(mag), 290% for α(mag)) and the skull cap (320% NRMS error for a(mag), 500% for α(mag)). Such over-predictions were largely due to out-of-plane motion. To model sensor error, we found that in-plane skin patch linear acceleration in the anterior-posterior direction could be modeled by an underdamped viscoelastic system. In summary, the mouthguard showed tighter skull coupling than the other sensor mounting approaches. Furthermore, the in vivo methods presented are valuable for investigating skull acceleration sensor technologies.

  14. The Head in "Wo Pao De Kuai."

    ERIC Educational Resources Information Center

    Dai, John Xiang-Ling.

    1992-01-01

    Analysis of six cross-linguistic properties characterizing the head verb in the resultative construction in Chinese shows that the first verb, and not the second verb, should be analyzed as the head verb. (15 references) (Author/CB)

  15. A Context-Aware EEG Headset System for Early Detection of Driver Drowsiness.

    PubMed

    Li, Gang; Chung, Wan-Young

    2015-08-21

    Driver drowsiness is a major cause of mortality in traffic accidents worldwide. Electroencephalographic (EEG) signal, which reflects the brain activities, is more directly related to drowsiness. Thus, many Brain-Machine-Interface (BMI) systems have been proposed to detect driver drowsiness. However, detecting driver drowsiness at its early stage poses a major practical hurdle when using existing BMI systems. This study proposes a context-aware BMI system aimed to detect driver drowsiness at its early stage by enriching the EEG data with the intensity of head-movements. The proposed system is carefully designed for low-power consumption with on-chip feature extraction and low energy Bluetooth connection. Also, the proposed system is implemented using JAVA programming language as a mobile application for on-line analysis. In total, 266 datasets obtained from six subjects who participated in a one-hour monotonous driving simulation experiment were used to evaluate this system. According to a video-based reference, the proposed system obtained an overall detection accuracy of 82.71% for classifying alert and slightly drowsy events by using EEG data alone and 96.24% by using the hybrid data of head-movement and EEG. These results indicate that the combination of EEG data and head-movement contextual information constitutes a robust solution for the early detection of driver drowsiness.

  16. A Context-Aware EEG Headset System for Early Detection of Driver Drowsiness

    PubMed Central

    Li, Gang; Chung, Wan-Young

    2015-01-01

    Driver drowsiness is a major cause of mortality in traffic accidents worldwide. Electroencephalographic (EEG) signal, which reflects the brain activities, is more directly related to drowsiness. Thus, many Brain-Machine-Interface (BMI) systems have been proposed to detect driver drowsiness. However, detecting driver drowsiness at its early stage poses a major practical hurdle when using existing BMI systems. This study proposes a context-aware BMI system aimed to detect driver drowsiness at its early stage by enriching the EEG data with the intensity of head-movements. The proposed system is carefully designed for low-power consumption with on-chip feature extraction and low energy Bluetooth connection. Also, the proposed system is implemented using JAVA programming language as a mobile application for on-line analysis. In total, 266 datasets obtained from six subjects who participated in a one-hour monotonous driving simulation experiment were used to evaluate this system. According to a video-based reference, the proposed system obtained an overall detection accuracy of 82.71% for classifying alert and slightly drowsy events by using EEG data alone and 96.24% by using the hybrid data of head-movement and EEG. These results indicate that the combination of EEG data and head-movement contextual information constitutes a robust solution for the early detection of driver drowsiness. PMID:26308002

  17. Mild Head Trauma and Chronic Headaches in Returning US Soldiers

    DTIC Science & Technology

    2009-04-01

    incidence and types of head or neck trauma among a cohort of US soldiers evaluated for chronic head - aches at a military neurology clinic following a...29.1 years. Head or neck trauma occurred during deployment in 33 of 81 (41%) of the soldiers referred to our clinic for head - aches . The causes of...consciousness. Ten soldiers also experienced a whiplash or neck injury while deployed. Multiple head or neck inju- Fig—Mechanism of head or neck

  18. Spatial Transformation of the Vestibulo-Ocular Reflex during Spaceflight

    NASA Technical Reports Server (NTRS)

    Clement, Gilles; Wood, Scott J.; Reschke, Millard F.

    1996-01-01

    It was hypothesized that the absence of the gravitational reference cues may be responsible for adaptive changes in the vestibulo-ocular reflex (VOR). These changes result in the alteration of the direction of the compensatory slow phase (SP) eye movements in microgravity. In order to test this hypothesis, the direction of the VOR SP relative to head motion was investigated in three astronauts during and after an eight-day orbital flight by passive sinusoidal pitch or yaw angular motion at two frequencies. The results of the inflight and postflight testing are considered. The observed deviation between VOR SP and head motion suggests that spatial transformation in the VOR occurred during adaptation to microgravity. It is considered that, although this spatial transformation might be due to a sensory bias, it may reflect central changes in the reference system used for spatial orientation in microgravity.

  19. Head tilt during driving.

    PubMed

    Zikovitz, D C; Harris, L R

    1999-05-01

    In order to distinguish between the use of visual and gravito-inertial force reference frames, the head tilt of drivers and passengers were measured as they went around corners at various speeds. The visual curvature of the corners were thus dissociated from the magnitude of the centripetal forces (0.30-0.77 g). Drivers' head tilts were highly correlated with the visually-available estimate of the curvature of the road (r2=0.86) but not with the centripetal force (r2<0.1). Passengers' head tilts were inversely correlated with the lateral forces (r2=0.3-0.7) and seem to reflect a passive sway. The strong correlation of the tilt of drivers' heads with a visual aspect of the road ahead, supports the use of a predominantly visual reference frame for the driving task.

  20. Cerebellar re-encoding of self-generated head movements

    PubMed Central

    Dugué, Guillaume P; Tihy, Matthieu; Gourévitch, Boris; Léna, Clément

    2017-01-01

    Head movements are primarily sensed in a reference frame tied to the head, yet they are used to calculate self-orientation relative to the world. This requires to re-encode head kinematic signals into a reference frame anchored to earth-centered landmarks such as gravity, through computations whose neuronal substrate remains to be determined. Here, we studied the encoding of self-generated head movements in the rat caudal cerebellar vermis, an area essential for graviceptive functions. We found that, contrarily to peripheral vestibular inputs, most Purkinje cells exhibited a mixed sensitivity to head rotational and gravitational information and were differentially modulated by active and passive movements. In a subpopulation of cells, this mixed sensitivity underlay a tuning to rotations about an axis defined relative to gravity. Therefore, we show that the caudal vermis hosts a re-encoded, gravitationally polarized representation of self-generated head kinematics in freely moving rats. DOI: http://dx.doi.org/10.7554/eLife.26179.001 PMID:28608779

  1. Drift Reduction in Pedestrian Navigation System by Exploiting Motion Constraints and Magnetic Field.

    PubMed

    Ilyas, Muhammad; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok

    2016-09-09

    Pedestrian navigation systems (PNS) using foot-mounted MEMS inertial sensors use zero-velocity updates (ZUPTs) to reduce drift in navigation solutions and estimate inertial sensor errors. However, it is well known that ZUPTs cannot reduce all errors, especially as heading error is not observable. Hence, the position estimates tend to drift and even cyclic ZUPTs are applied in updated steps of the Extended Kalman Filter (EKF). This urges the use of other motion constraints for pedestrian gait and any other valuable heading reduction information that is available. In this paper, we exploit two more motion constraints scenarios of pedestrian gait: (1) walking along straight paths; (2) standing still for a long time. It is observed that these motion constraints (called "virtual sensor"), though considerably reducing drift in PNS, still need an absolute heading reference. One common absolute heading estimation sensor is the magnetometer, which senses the Earth's magnetic field and, hence, the true heading angle can be calculated. However, magnetometers are susceptible to magnetic distortions, especially in indoor environments. In this work, an algorithm, called magnetic anomaly detection (MAD) and compensation is designed by incorporating only healthy magnetometer data in the EKF updating step, to reduce drift in zero-velocity updated INS. Experiments are conducted in GPS-denied and magnetically distorted environments to validate the proposed algorithms.

  2. MetalMapper: A Multi-Sensor TEM System for UXO Detection and Classification

    DTIC Science & Technology

    2011-04-01

    fluxgate magnetometer that provides reference heading to magnetic north. DeploymentCThe MM can be deployed either as a man-powered cart or as a...is a live site. Preliminary investigations included a magnetometer transect survey and an EMI survey over a larger area to assist in selecting a

  3. A Description and Source Listing of Curriculum Materials in Agricultural Education, 1969-1970.

    ERIC Educational Resources Information Center

    American Vocational Association, Washington, DC. Agricultural Education Div.

    The purpose of this annotated bibliography is to provide teachers of vocational agriculture, agricultural supervisors, and agricultural teacher educators with information on current curriculum materials available to them. Classified according to the AGDEX filing system, the 163 references are grouped under the headings: (1) Field Crops, (2)…

  4. Heading Tuning in Macaque Area V6.

    PubMed

    Fan, Reuben H; Liu, Sheng; DeAngelis, Gregory C; Angelaki, Dora E

    2015-12-16

    Cortical areas, such as the dorsal subdivision of the medial superior temporal area (MSTd) and the ventral intraparietal area (VIP), have been shown to integrate visual and vestibular self-motion signals. Area V6 is interconnected with areas MSTd and VIP, allowing for the possibility that V6 also integrates visual and vestibular self-motion cues. An alternative hypothesis in the literature is that V6 does not use these sensory signals to compute heading but instead discounts self-motion signals to represent object motion. However, the responses of V6 neurons to visual and vestibular self-motion cues have never been studied, thus leaving the functional roles of V6 unclear. We used a virtual reality system to examine the 3D heading tuning of macaque V6 neurons in response to optic flow and inertial motion stimuli. We found that the majority of V6 neurons are selective for heading defined by optic flow. However, unlike areas MSTd and VIP, V6 neurons are almost universally unresponsive to inertial motion in the absence of optic flow. We also explored the spatial reference frames of heading signals in V6 by measuring heading tuning for different eye positions, and we found that the visual heading tuning of most V6 cells was eye-centered. Similar to areas MSTd and VIP, the population of V6 neurons was best able to discriminate small variations in heading around forward and backward headings. Our findings support the idea that V6 is involved primarily in processing visual motion signals and does not appear to play a role in visual-vestibular integration for self-motion perception. To understand how we successfully navigate our world, it is important to understand which parts of the brain process cues used to perceive our direction of self-motion (i.e., heading). Cortical area V6 has been implicated in heading computations based on human neuroimaging data, but direct measurements of heading selectivity in individual V6 neurons have been lacking. We provide the first demonstration that V6 neurons carry 3D visual heading signals, which are represented in an eye-centered reference frame. In contrast, we found almost no evidence for vestibular heading signals in V6, indicating that V6 is unlikely to contribute to multisensory integration of heading signals, unlike other cortical areas. These findings provide important constraints on the roles of V6 in self-motion perception. Copyright © 2015 the authors 0270-6474/15/3516303-12$15.00/0.

  5. Monitoring contamination due to materials outgassing by QCM-based sensors

    NASA Astrophysics Data System (ADS)

    Dirri, Fabrizio

    2016-07-01

    F. Dirri, E. Palomba, A. Longobardo, D. Biondi, A. Boccaccini, E. Zampetti, B. Saggin, D. Scaccabarozzi, A. Tortora, A. Nanni, J. Alves, A. Tighe Outgassing from spacecraft materials often occurs and degassing contaminants can degrade critical spacecraft surfaces, such as optical systems, solar panels, thermal radiators and thermal management systems. The main contaminants are the water adsorbed by cold surface, organics from spacecraft structure, electronics, insulation and thrusters firings [1]. Thus, it is fundamental to monitor these low-outgassing rates especially in a long duration mission: Quartz Crystal Microbalance (QCM) based sensors (i.e. single and double crystal configurations) are a suitable instruments to monitor step by step these degradation processes which occur in space conditions. The Contamination Assessment Microbalance (CAM) is a device aimed at monitoring in-orbit contamination of sensitive surfaces and payloads on ESA's future satellites. The device, developed by a consortium of Italian research Institutes, is based on QCM technology, previously considered by NASA and ESA experiments performed on Space Shuttle and satellite missions [2,3,4]. CAM is a low mass (200 grams for the sensor head), low volume (smaller than 5x5x5 cm3 for the sensor head) and low power consumption (less than 1.5 W) sensor. The device is composed by: 1) the Sensor Head, containing a sensing crystal (which measures the deposited contaminant mass), a reference crystal (used as frequency reference), their related Proximity Electronics (PE) and a Temperature Control System (TCS); 2) the Main Electronics Unit (MEU), which acquires the signal in output from Sensor Head unit; 3) the Harness connecting Sensor Head and MEU; 4) the User Interface (UI) to read and display the data. The device shows several improvements, i.e. possibility to measure directly the crystal temperature (with an accuracy better than 0.1°C), large measurable mass range (from 5•10-9 to 7•10-4 g/cm2), large operative temperature range (from -80°C to 130°C), temperature stability within 0.5°C and good frequency resolution of 0.1 Hz. The instruments concept and the performance evaluation, based on tests performed on the QCM based sensors (i.e. simulating an outgassing source in space conditions), are presented in this work. References : [1] Soares et al. 2003, Proc. SPIE, 09/2000; [2] Miller 1982, Report NASA TM- 82457; [3] Tighe et al. 2009, AIP Conf. Proc. 1087, 195; [4] Wood et al. 1997, AIAA 97-0841

  6. Future Scenarios of Livestock and Land Use in Brazil

    NASA Astrophysics Data System (ADS)

    Costa, M. H.; Abrahão, G. M.

    2016-12-01

    Brazil currently has about 213 M cattle heads in 151 M ha of pastures. In the last 40 years, both the top 5% and the average stocking rate are increasing exponentially in Brazil, while the relative yield gap has been constant. Using these historical relationships, we estimate future scenarios of livestock and land use in Brazil. We assume a reference scenario for the top 5%, in which pasturelands are adequately fertilized, soil is not compacted and well drained, grasses are never burned, pastures are divided in 8 subdivisions of regular area, are cattle is rotated through the subdivisions. The reference scenario does not consider irrigation or feed supplementation. We calibrate a computer model and run it for the pasturelands throughout the entire country. We conclude that current pastures have about 20% efficiency to raise cattle compared to the reference scenario. Considering the reference scenario, we predict an equilibrium will be reached in about 100 years, with top 5% with about 9.3 heads per ha and the average 4.3 heads per ha, or 600 M heads of livestock. Considering a more pessimistic scenario, which considers an inflection of the curve in present times, we predict an equilibrium will be reached in about 60 years, with the top 5% stocking rate equal to 4.3 heads per ha and the average equal to 2.2 heads per ha, or 300 M heads of livestock. Both cases represent a considerable expansion of the livestock, maybe even higher than the growth of the global demands for beef. These scenarios indicate that not all existing pasturelands need to be used in the future - a significant part of them may be converted to croplands, which will also contribute to the reduction of deforestation.

  7. Compendium of NASA Langley reports on hypersonic aerodynamics

    NASA Technical Reports Server (NTRS)

    Sabo, Frances E.; Cary, Aubrey M.; Lawson, Shirley W.

    1987-01-01

    Reference is made to papers published by the Langley Research Center in various areas of hypersonic aerodynamics for the period 1950 to 1986. The research work was performed either in-house by the Center staff or by other personnel supported entirely or in part by grants or contracts. Abstracts have been included with the references when available. The references are listed chronologically and are grouped under the following general headings: (1) Aerodynamic Measurements - Single Shapes; (2) Aerodynamic Measurements - Configurations; (3) Aero-Heating; (4) Configuration Studies; (5) Propulsion Integration Experiment; (6) Propulsion Integration - Study; (7) Analysis Methods; (8) Test Techniques; and (9) Airframe Active Cooling Systems.

  8. A vector autopilot system. [aircraft attitude determination with three-axis magnetometer

    NASA Technical Reports Server (NTRS)

    Pietila, R.; Dunn, W. R., Jr.

    1976-01-01

    Current technology has evolved low cost, highly reliable solid state vector magnetometers with excellent angular resolution. This paper discusses the role of a three-axis magnetometer as a new instrument for aircraft attitude determination. Using flight data acquired by an instrumented aircraft, attitude is calculated using the earth's magnetic field vector and compared to measured attitudes. The magnetic field alone is not adequate to resolve all attitude variations and the need for a second reference angle or vector is discussed. A system combining the functions of heading determination and attitude measurement is presented to show that both functions can be implemented with essentially the same component count required to measure heading alone. It is concluded that with the correlation achieved in calculated and measured attitude there is a potential application of vector magnetometry in attitude measurement systems.

  9. Improvement of absolute positioning of precision stage based on cooperation the zero position pulse signal and incremental displacement signal

    NASA Astrophysics Data System (ADS)

    Wang, H. H.; Shi, Y. P.; Li, X. H.; Ni, K.; Zhou, Q.; Wang, X. H.

    2018-03-01

    In this paper, a scheme to measure the position of precision stages, with a high precision, is presented. The encoder is composed of a scale grating and a compact two-probe reading head, to read the zero position pulse signal and continuous incremental displacement signal. The scale grating contains different codes, multiple reference codes with different spacing superimposed onto the incremental grooves with an equal spacing structure. The codes of reference mask in the reading head is the same with the reference codes on the scale grating, and generate pulse signal to locate the reference position primarily when the reading head moves along the scale grating. After locating the reference position in a section by means of the pulse signal, the reference position can be located precisely with the amplitude of the incremental displacement signal. A kind of reference codes and scale grating were designed, and experimental results show that the primary precision of the design achieved is 1 μ m. The period of the incremental signal is 1μ m, and 1000/N nm precision can be achieved by subdivide the incremental signal in N times.

  10. Finite element analyses of railroad tank car head impacts

    DOT National Transportation Integrated Search

    2008-09-24

    This paper describes engineering analyses of a railroad : tank car impacted at its head by a rigid punch. This type of : collision, referred to as a head impact, is examined using : dynamic, nonlinear finite element analysis (FEA). : Commercial softw...

  11. 49 CFR 214.113 - Head protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Bridge Worker Safety Standards § 214.113 Head... conform to the national consensus standards for industrial head protection (American National Standards Institute, Z89.1-1986, Protective Headwear for Industrial Workers). This incorporation by reference was...

  12. 29 CFR 1918.103 - Head protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR LONGSHORING Personal Protective Equipment § 1918.103 Head...-2003, “American National Standard for Industrial Head Protection,” which is incorporated by reference...

  13. 49 CFR 214.113 - Head protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Bridge Worker Safety Standards § 214.113 Head... conform to the national consensus standards for industrial head protection (American National Standards Institute, Z89.1-1986, Protective Headwear for Industrial Workers). This incorporation by reference was...

  14. 49 CFR 214.113 - Head protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Bridge Worker Safety Standards § 214.113 Head... conform to the national consensus standards for industrial head protection (American National Standards Institute, Z89.1-1986, Protective Headwear for Industrial Workers). This incorporation by reference was...

  15. 49 CFR 214.113 - Head protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Bridge Worker Safety Standards § 214.113 Head... conform to the national consensus standards for industrial head protection (American National Standards Institute, Z89.1-1986, Protective Headwear for Industrial Workers). This incorporation by reference was...

  16. Design and validation of an open-source library of dynamic reference frames for research and education in optical tracking.

    PubMed

    Brown, Alisa; Uneri, Ali; Silva, Tharindu De; Manbachi, Amir; Siewerdsen, Jeffrey H

    2018-04-01

    Dynamic reference frames (DRFs) are a common component of modern surgical tracking systems; however, the limited number of commercially available DRFs poses a constraint in developing systems, especially for research and education. This work presents the design and validation of a large, open-source library of DRFs compatible with passive, single-face tracking systems, such as Polaris stereoscopic infrared trackers (NDI, Waterloo, Ontario). An algorithm was developed to create new DRF designs consistent with intra- and intertool design constraints and convert to computer-aided design (CAD) files suitable for three-dimensional printing. A library of 10 such groups, each with 6 to 10 DRFs, was produced and tracking performance was validated in comparison to a standard commercially available reference, including pivot calibration, fiducial registration error (FRE), and target registration error (TRE). Pivot tests showed calibration error [Formula: see text], indistinguishable from the reference. FRE was [Formula: see text], and TRE in a CT head phantom was [Formula: see text], both equivalent to the reference. The library of DRFs offers a useful resource for surgical navigation research and could be extended to other tracking systems and alternative design constraints.

  17. Evaluation of the accuracy and clinical practicality of a calculation system for patient positional displacement in carbon ion radiotherapy at five sites.

    PubMed

    Kubota, Yoshiki; Hayashi, Hayato; Abe, Satoshi; Souda, Saki; Okada, Ryosuke; Ishii, Takayoshi; Tashiro, Mutsumi; Torikoshi, Masami; Kanai, Tatsuaki; Ohno, Tatsuya; Nakano, Takashi

    2018-03-01

    We developed a system for calculating patient positional displacement between digital radiography images (DRs) and digitally reconstructed radiography images (DRRs) to reduce patient radiation exposure, minimize individual differences between radiological technologists in patient positioning, and decrease positioning time. The accuracy of this system at five sites was evaluated with clinical data from cancer patients. The dependence of calculation accuracy on the size of the region of interest (ROI) and initial position was evaluated for clinical use. For a preliminary verification, treatment planning and positioning data from eight setup patterns using a head and neck phantom were evaluated. Following this, data from 50 patients with prostate, lung, head and neck, liver, or pancreatic cancer (n = 10 each) were evaluated. Root mean square errors (RMSEs) between the results calculated by our system and the reference positions were assessed. The reference positions were manually determined by two radiological technologists to best-matching positions with orthogonal DRs and DRRs in six axial directions. The ROI size dependence was evaluated by comparing RMSEs for three different ROI sizes. Additionally, dependence on initial position parameters was evaluated by comparing RMSEs for four position patterns. For the phantom study, the average (± standard deviation) translation error was 0.17 ± 0.05, rotation error was 0.17 ± 0.07, and ΔD was 0.14 ± 0.05. Using the optimal ROI size for each patient site, all cases of prostate, lung, and head and neck cancer with initial position parameters of 10 mm or under were acceptable in our tolerance. However, only four liver cancer cases and three pancreatic cancer cases were acceptable, because of low-reproducibility regions in the ROIs. Our system has clinical practicality for prostate, lung, and head and neck cancer cases. Additionally, our findings suggest ROI size dependence in some cases. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  18. Soft tissue examination of the fetal rat and rabbit head by magnetic resonance imaging.

    PubMed

    French, Julian M; Woodhouse, Neil

    2013-01-01

    The use of magnetic resonance imaging of the fetal rat and rabbit head, as an alternative to the traditional methods of fixation and preparation of serial sections, is described. Labeled magnetic resonance images of normal head anatomy have been provided as a reference for use when evaluating the internal structures of the head.

  19. 49 CFR 572.152 - Head assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Head assembly and test procedure. 572.152 Section... 12-Month-Old Infant, Alpha Version § 572.152 Head assembly and test procedure. (a) The head assembly (refer to § 572.150(a)(1)(i)) for this test consists of the assembly (drawing 921022-001), triaxial mount...

  20. 49 CFR 572.152 - Head assembly and test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Head assembly and test procedure. 572.152 Section... 12-Month-Old Infant, Alpha Version § 572.152 Head assembly and test procedure. (a) The head assembly (refer to § 572.150(a)(1)(i)) for this test consists of the assembly (drawing 921022-001), triaxial mount...

  1. 49 CFR 572.152 - Head assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Head assembly and test procedure. 572.152 Section... 12-Month-Old Infant, Alpha Version § 572.152 Head assembly and test procedure. (a) The head assembly (refer to § 572.150(a)(1)(i)) for this test consists of the assembly (drawing 921022-001), triaxial mount...

  2. 49 CFR 572.152 - Head assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Head assembly and test procedure. 572.152 Section... 12-Month-Old Infant, Alpha Version § 572.152 Head assembly and test procedure. (a) The head assembly (refer to § 572.150(a)(1)(i)) for this test consists of the assembly (drawing 921022-001), triaxial mount...

  3. Comparison of estimation accuracy of body density between different hydrostatics weighing methods without head submersion.

    PubMed

    Demura, Shinichi; Sato, Susumu; Nakada, Masakatsu; Minami, Masaki; Kitabayashi, Tamotsu

    2003-07-01

    This study compared the accuracy of body density (Db) estimation methods using hydrostatic weighing without complete head submersion (HW(withoutHS)) of Donnelly et al. (1988) and Donnelly and Sintek (1984) as referenced to Goldman and Buskirk's approach (1961). Donnelly et al.'s method estimates Db from a regression equation using HW(withoutHS), moreover, Donnelly and Sintek's method estimates it from HW(withoutHS) and head anthropometric variables. Fifteen Japanese males (173.8+/-4.5 cm, 63.6+/-5.4 kg, 21.2+/-2.8 years) and fifteen females (161.4+/-5.4 cm, 53.8+/-4.8 kg, 21.0+/-1.4 years) participated in this study. All the subjects were measured for head length, width and HWs under the two conditions of with and without head submersion. In order to examine the consistency of estimation values of Db, the correlation coefficients between the estimation values and the reference (Goldman and Buskirk, 1961) were calculated. The standard errors of estimation (SEE) were calculated by regression analysis using a reference value as a dependent variable and estimation values as independent variables. In addition, the systematic errors of two estimation methods were investigated by the Bland-Altman technique (Bland and Altman, 1986). In the estimation, Donnelly and Sintek's equation showed a high relationship with the reference (r=0.960, p<0.01), but had more differences from the reference compared with Donnelly et al.'s equation. Further studies are needed to develop new prediction equations for Japanese considering sex and individual differences in head anthropometry.

  4. 14 CFR Appendix E to Part 125 - Airplane Flight Recorder Specifications

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... flight crew reference) 0-360° and Discrete “true” or “mag” ±2° 1 0.5° When true or magnetic heading can be selected as the primary heading reference, a discrete indicating selection must be recorded. 5... synchronizationreference On-Off (Discrete)None. 1 Preferably each crew member but one discrete acceptable for all...

  5. 14 CFR Appendix M to Part 121 - Airplane Flight Recorder Specifications

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Discrete “true” or “mag” ±2° 1 0.5° When true or magnetic heading can be selected as the primary heading reference, a discrete indicating selection must be recorded. 5. Normal acceleration (vertical) 9 −3g to +6g.... Manual Radio Transmitter Keying or CVR/DFDR synchronization reference On-Off (Discrete)None 1 Preferably...

  6. Flight display dynamics and compensatory head movements in pilots.

    PubMed

    Beer, Jeremy; Freeman, David

    2007-06-01

    Experiments measured the optokinetic cervical reflex (OKCR), wherein the banking pilot aligns the head with the horizon. In a synthetic cockpit, the flight display was manipulated to test whether changing the visual reference frame would alter OKCR. Eight subjects (five rated pilots) flew a route in simulated visual meteorological conditions that required them to bank the aircraft frequently. Pilots' head tilt was characterized using both the conventional method of regressing against simultaneous aircraft bank, and also an event-based analysis, which identified head movements before, during, and after each turn. Three display configurations were compared to determine whether pilots' orientation would ever migrate from the horizon to the aircraft symbol. The first was a conventional "Inside-Out" condition. A "Frequency-Separated" condition combined Inside-Out horizon geometry with Outside-In dynamics for the aircraft symbol, which depicted joystick bank inputs. In the "Outside-In" condition, the aircraft symbol rolled against a static horizon. Regressions identified an interaction (p < 0.001) between display condition and aircraft bank: head tilt followed horizon tilt in Inside-Out and Frequency-Separated conditions, while remaining mostly level in the Outside-In condition. The event-based analysis identified anticipatory head movements in Inside-Out and Frequency-Separated conditions: 95% CI indicated that before each turn, head tilt favored the direction of the imminent bank. While the conventional analysis confirmed that the horizon comprises a primary spatial reference, the finer-grained event-based analysis indicated that pilots' reference can migrate at least temporarily to the vehicle, and that OKCR can be preceded by anticipatory head movements in the opposite direction.

  7. UAV State Estimation Modeling Techniques in AHRS

    NASA Astrophysics Data System (ADS)

    Razali, Shikin; Zhahir, Amzari

    2017-11-01

    Autonomous unmanned aerial vehicle (UAV) system is depending on state estimation feedback to control flight operation. Estimation on the correct state improves navigation accuracy and achieves flight mission safely. One of the sensors configuration used in UAV state is Attitude Heading and Reference System (AHRS) with application of Extended Kalman Filter (EKF) or feedback controller. The results of these two different techniques in estimating UAV states in AHRS configuration are displayed through position and attitude graphs.

  8. 29 CFR 1917.93 - Head protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED..., “American National Standard for Industrial Head Protection,” incorporated by reference in § 1917.3; (ii) American National Standards Institute (ANSI) Z89.1-2003, “American National Standard for Industrial Head...

  9. 29 CFR 1917.93 - Head protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED..., “American National Standard for Industrial Head Protection,” incorporated by reference in § 1917.3; (ii) American National Standards Institute (ANSI) Z89.1-2003, “American National Standard for Industrial Head...

  10. Head circumference growth reference charts for Turkish children aged 0-84 months.

    PubMed

    Elmali, Ferhan; Altunay, Canan; Mazicioglu, Mümtaz M; Kondolot, Meda; Ozturk, Ahmet; Kurtoglu, Selim

    2012-05-01

    This study sought to produce updated head circumference references in a representative population of Turkish children aged 0 to <84 months. Head circumference measurements are very important in monitoring child growth, to evaluate macrocephaly and microcephaly. Primary sampling units involved family health centers in the city center and suburbs of Kayseri. In total, 2989 children (1479 boys and 1510 girls) were included. Head circumference was measured with a nonelastic tape on a line passing over the glabella and posterior occipital protrusion in children aged 0-2 years lying on a bed, and children aged more than 2 years standing up. We compared the 50th percentile of our cross-sectional data with longitudinal Belgian and American data. The comparison indicated that Turkish head circumference percentiles were similar to, or not much lower than, Belgian and American percentiles. Head circumference percentiles can be used to evaluate children with microcephaly and macrocephaly (±2 standard deviations), and to monitor growth. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Variability in the control of head movements in seated humans: a link with whiplash injuries?

    PubMed Central

    Vibert, N; MacDougall, H G; de Waele, C; Gilchrist, D P D; Burgess, A M; Sidis, A; Migliaccio, A; Curthoys, I S; Vidal, P P

    2001-01-01

    The aim of this study was to determine how context and on-line sensory information are combined to control posture in seated subjects submitted to high-jerk, passive linear accelerations. Subjects were seated with eyes closed on a servo-controlled linear sled. They were asked to relax and received brief accelerations either sideways or in the fore-aft direction. The stimuli had an abrupt onset, comparable to the jerk experienced during a minor car collision. Rotation and translation of the head and body were measured using an Optotrak system. In some of the subjects, surface electromyographic (EMG) responses of selected neck and/or back muscles were recorded simultaneously. For each subject, responses were highly stereotyped from the first trial, and showed little sign of habituation or sensitisation. Comparable results were obtained with sideways and fore-aft accelerations. During each impulse, the head lagged behind the trunk for several tens of milliseconds. The subjects' head movement responses were distributed as a continuum in between two extreme categories. The ‘stiff’ subjects showed little rotation or translation of the head relative to the trunk for the whole duration of the impulse. In contrast, the ‘floppy’ subjects showed a large roll or pitch of the head relative to the trunk in the direction opposite to the sled movement. This response appeared as an exaggerated ‘inertial’ response to the impulse. Surface EMG recordings showed that most of the stiff subjects were not contracting their superficial neck or back muscles. We think they relied on bilateral contractions of their deep, axial musculature to keep the head-neck ensemble in line with the trunk during the movement. About half of the floppy subjects displayed reflex activation of the neck muscles on the side opposite to the direction of acceleration, which occurred before or during the head movement and tended to exaggerate it. The other floppy subjects seemed to rely on only the passive biomechanical properties of their head-neck ensemble to compensate for the perturbation. In our study, proprioception was the sole source of sensory information as long as the head did not move. We therefore presume that the EMG responses and head movements we observed were mainly triggered by the activation of stretch receptors in the hips, trunk and/or neck. The visualisation of an imaginary reference in space during sideways impulses significantly reduced the head roll exhibited by floppy subjects. This suggests that the adoption by the central nervous system of an extrinsic, ‘allocentric’ frame of reference instead of an intrinsic, ‘egocentric’ one may be instrumental for the selection of the stiff strategy. The response of floppy subjects appeared to be maladaptive and likely to increase the risk of whiplash injury during motor vehicle accidents. Evolution of postural control may not have taken into account the implications of passive, high-acceleration perturbations affecting seated subjects. PMID:11313451

  12. Puma (Puma concolor) epididymal sperm morphometry

    PubMed Central

    Cucho, Hernán; Alarcón, Virgilio; Ordóñez, César; Ampuero, Enrique; Meza, Aydee; Soler, Carles

    2016-01-01

    The Andean puma (Puma concolor) has not been widely studied, particularly in reference to its semen characteristics. The aim of the present study was to define the morphometry of puma sperm heads and classify their subpopulations by cluster analysis. Samples were recovered postmortem from two epididymides from one animal and prepared for morphological observation after staining with the Hemacolor kit. Morphometric data were obtained from 581 spermatozoa using a CASA-Morph system, rendering 13 morphometric parameters. The principal component (PC) analysis was performed followed by cluster analysis for the establishment of subpopulations. Two PC components were obtained, the first related to size and the second to shape. Three subpopulations were observed, corresponding to elongated and intermediate-size sperm heads and acrosomes, to large heads with large acrosomes, and to small heads with short acrosomes. In conclusion, puma spermatozoa showed no uniform sperm morphology but three clear subpopulations. These results should be used for future work in the establishment of an adequate germplasm bank of this species. PMID:27678466

  13. Puma (Puma concolor) epididymal sperm morphometry.

    PubMed

    Cucho, Hernán; Alarcón, Virgilio; Ordóñez, César; Ampuero, Enrique; Meza, Aydee; Soler, Carles

    2016-01-01

    The Andean puma (Puma concolor) has not been widely studied, particularly in reference to its semen characteristics. The aim of the present study was to define the morphometry of puma sperm heads and classify their subpopulations by cluster analysis. Samples were recovered postmortem from two epididymides from one animal and prepared for morphological observation after staining with the Hemacolor kit. Morphometric data were obtained from 581 spermatozoa using a CASA-Morph system, rendering 13 morphometric parameters. The principal component (PC) analysis was performed followed by cluster analysis for the establishment of subpopulations. Two PC components were obtained, the first related to size and the second to shape. Three subpopulations were observed, corresponding to elongated and intermediate-size sperm heads and acrosomes, to large heads with large acrosomes, and to small heads with short acrosomes. In conclusion, puma spermatozoa showed no uniform sperm morphology but three clear subpopulations. These results should be used for future work in the establishment of an adequate germplasm bank of this species.

  14. Integration and flight test of a biomimetic heading sensor

    NASA Astrophysics Data System (ADS)

    Chahl, Javaan; Mizutani, Akiko

    2013-04-01

    We report on the first successful development and implementation of an automatic polarisation compass as the primary heading sensor for a UAV. Polarisation compassing is the primary navigation sense of many flying and walking insects, including bees, ants and crickets. Manually operated polarisation astrolabes were fitted in some passenger airliners prior to the implementation of the global positioning system, to compensate for the overal degradation of magnetic and gyrocompass sensors in polar regions. The device we developed demonstrated accurate determination of the direction of the Sun, with repeatability of better than 0.2 degrees. These figures are comparable to any solid state magnetic compass, including flux gate based devices. Flight trials were undertaken in which the output of the polarimeter was the only heading reference used by the aircraft as it flew through GPS waypoints.

  15. Referred pain from myofascial trigger points in head and neck-shoulder muscles reproduces head pain features in children with chronic tension type headache.

    PubMed

    Fernández-de-las-Peñas, César; Fernández-Mayoralas, Daniel M; Ortega-Santiago, Ricardo; Ambite-Quesada, Silvia; Palacios-Ceña, Domingo; Pareja, Juan A

    2011-02-01

    Our aim was to describe the referred pain pattern and areas from trigger points (TrPs) in head, neck, and shoulder muscles in children with chronic tension type headache (CTTH). Fifty children (14 boys, 36 girls, mean age: 8 ± 2) with CTTH and 50 age- and sex- matched children participated. Bilateral temporalis, masseter, superior oblique, upper trapezius, sternocleidomastoid, suboccipital, and levator scapula muscles were examined for TrPs by an assessor blinded to the children's condition. TrPs were identified with palpation and considered active when local and referred pains reproduce headache pain attacks. The referred pain areas were drawn on anatomical maps, digitalized, and also measured. The total number of TrPs was significantly greater in children with CTTH as compared to healthy children (P < 0.001). Active TrPs were only present in children with CTTH (P < 0.001). Within children with CTTH, a significant positive association between the number of active TrPs and headache duration (r (s) = 0.315; P = 0.026) was observed: the greater the number of active TrPs, the longer the duration of headache attack. Significant differences in referred pain areas between groups (P < 0.001) and muscles (P < 0.001) were found: the referred pain areas were larger in CTTH children (P < 0.001), and the referred pain area elicited by suboccipital TrPs was larger than the referred pain from the remaining TrPs (P < 0.001). Significant positive correlations between some headache clinical parameters and the size of the referred pain area were found. Our results showed that the local and referred pains elicited from active TrPs in head, neck and shoulder shared similar pain pattern as spontaneous CTTH in children, supporting a relevant role of active TrPs in CTTH in children.

  16. Rotary head type reproducing apparatus

    DOEpatents

    Takayama, Nobutoshi; Edakubo, Hiroo; Kozuki, Susumu; Takei, Masahiro; Nagasawa, Kenichi

    1986-01-01

    In an apparatus of the kind arranged to reproduce, with a plurality of rotary heads, an information signal from a record bearing medium having many recording tracks which are parallel to each other with the information signal recorded therein and with a plurality of different pilot signals of different frequencies also recorded one by one, one in each of the recording tracks, a plurality of different reference signals of different frequencies are simultaneously generated. A tracking error is detected by using the different reference signals together with the pilot signals which are included in signals reproduced from the plurality of rotary heads.

  17. Visual-conformal display format for helicopter guidance

    NASA Astrophysics Data System (ADS)

    Doehler, H.-U.; Schmerwitz, Sven; Lueken, Thomas

    2014-06-01

    Helicopter guidance in situations where natural vision is reduced is still a challenging task. Beside new available sensors, which are able to "see" through darkness, fog and dust, display technology remains one of the key issues of pilot assistance systems. As long as we have pilots within aircraft cockpits, we have to keep them informed about the outside situation. "Situational awareness" of humans is mainly powered by their visual channel. Therefore, display systems which are able to cross-fade seamless from natural vision to artificial computer vision and vice versa, are of greatest interest within this context. Helmet-mounted displays (HMD) have this property when they apply a head-tracker for measuring the pilot's head orientation relative to the aircraft reference frame. Together with the aircraft's position and orientation relative to the world's reference frame, the on-board graphics computer can generate images which are perfectly aligned with the outside world. We call image elements which match the outside world, "visual-conformal". Published display formats for helicopter guidance in degraded visual environment apply mostly 2D-symbologies which stay far behind from what is possible. We propose a perspective 3D-symbology for a head-tracked HMD which shows as much as possible visual-conformal elements. We implemented and tested our proposal within our fixed based cockpit simulator as well as in our flying helicopter simulator (FHS). Recently conducted simulation trials with experienced helicopter pilots give some first evaluation results of our proposal.

  18. Randomized, investigator-blinded, controlled clinical study with lice shampoo (Licener®) versus dimethicone (Jacutin® Pedicul Fluid) for the treatment of infestations with head lice.

    PubMed

    Semmler, Margit; Abdel-Ghaffar, Fathy; Gestmann, Falk; Abdel-Aty, Mohammed; Rizk, Ibrahim; Al-Quraishy, Saleh; Lehmacher, Walter; Hoff, Norman-Philipp

    2017-07-01

    The present clinical trial was conducted to obtain additional data for the safety and efficacy of a head lice shampoo that is free of silicone compared with an anti-head lice product containing dimethicone. Both products act by a physical mode of action. This randomized, investigator-blinded, controlled clinical study was conducted between July and November 2016 in households of two villages (Abou Rawash and Shandalat) in Egypt. Children older than 2 years with an active head lice infestation were treated with either a shampoo-based head lice treatment containing neem extract (Licener®) or dimethicone (Jacutin® Pedicul Fluid) on day 1 and additionally on day 9. Assessment for living lice by combing was conducted before and 1-2 h after treatment and on days 5 and 13. The main objective was to demonstrate a cure rate of the test product of at least 85% after a single application (day 5 and 9). Secondary objectives were to scrutinize patient safety and satisfaction as well as cure rates on day 13 after two treatments and the evaluation of ovicidal and licicidal efficacies of the products. Sixty-one children in the test-group (Licener®) and 58 children in the reference group (Jacutin® Pedicul Fluid) were included in this study. The test product and the reference product were very well tolerated. Both products exceeded the objective of cure rates of over 85% after single treatment (test group 60/60 = 100%; 95% CI = 94.04-100.00%; reference group 54/57 = 94.74%; 95% CI = 85.38-98.90%; p = 0.112; CI by Clopper-Pearson) and after two treatments (test group 58/58 = 100%; 95% CI = 93.84-100.00%; reference group 52/54 = 96.30%; 95% CI = 87.25-99.55%; p = 0.230) with higher cure rates and non-inferiority for the test product. The combined success rate shows significant superiority of the test product against the reference product (test group 58/58 = 100%; 95% CI = 93.84-100.00%; reference group 49/54 = 90.7%; 95% CI = 79.70-96.92%; p = 0.024). The test product showed higher ovicidal efficacy than the reference product. Thus, the present study demonstrates that a single treatment with a head lice product like Licener® can be sufficient to eliminate a head lice infestation.

  19. Effect of eye position during human visual-vestibular integration of heading perception.

    PubMed

    Crane, Benjamin T

    2017-09-01

    Visual and inertial stimuli provide heading discrimination cues. Integration of these multisensory stimuli has been demonstrated to depend on their relative reliability. However, the reference frame of visual stimuli is eye centered while inertia is head centered, and it remains unclear how these are reconciled with combined stimuli. Seven human subjects completed a heading discrimination task consisting of a 2-s translation with a peak velocity of 16 cm/s. Eye position was varied between 0° and ±25° left/right. Experiments were done with inertial motion, visual motion, or a combined visual-inertial motion. Visual motion coherence varied between 35% and 100%. Subjects reported whether their perceived heading was left or right of the midline in a forced-choice task. With the inertial stimulus the eye position had an effect such that the point of subjective equality (PSE) shifted 4.6 ± 2.4° in the gaze direction. With the visual stimulus the PSE shift was 10.2 ± 2.2° opposite the gaze direction, consistent with retinotopic coordinates. Thus with eccentric eye positions the perceived inertial and visual headings were offset ~15°. During the visual-inertial conditions the PSE varied consistently with the relative reliability of these stimuli such that at low visual coherence the PSE was similar to that of the inertial stimulus and at high coherence it was closer to the visual stimulus. On average, the inertial stimulus was weighted near Bayesian ideal predictions, but there was significant deviation from ideal in individual subjects. These findings support visual and inertial cue integration occurring in independent coordinate systems. NEW & NOTEWORTHY In multiple cortical areas visual heading is represented in retinotopic coordinates while inertial heading is in body coordinates. It remains unclear whether multisensory integration occurs in a common coordinate system. The experiments address this using a multisensory integration task with eccentric gaze positions making the effect of coordinate systems clear. The results indicate that the coordinate systems remain separate to the perceptual level and that during the multisensory task the perception depends on relative stimulus reliability. Copyright © 2017 the American Physiological Society.

  20. Bibliography of borehole geophysics as applied to ground-water hydrology

    USGS Publications Warehouse

    Taylor, Ticie A.; Dey, Joyce A.

    1985-01-01

    Most of the references on borehole geophysics that are relevant to ground-water hydrology are contained in this bibliography, but it does not include every reference that is available under each subject heading; the literature is much too extensive to compile a complete listing. Some of the references may appear under more than one subject heading because the references commonly relate to more than one main topic. Many articles have been cross-referenced in order to assist the reader in locating an article. For example, the article entitled, 'Application of the acoustic televiewer to the characterization of hydraulic fractures in geothermal wells' is listed under both 'Acoustic televiewer,' and 'Geothermal'. The bibliography is intended to lead the reader to other articles on borehole-geophysical logging and related subjects, because each article cited also will have a list of references, which may be more specialized, covering many subjects with related applications, such as physics, mathematics, chemistry, geology, electronics, acoustics, hydrology, and surface geophysics. However, not all of these related subject headings could be included in this bibliography.

  1. Drift Reduction in Pedestrian Navigation System by Exploiting Motion Constraints and Magnetic Field

    PubMed Central

    Ilyas, Muhammad; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok

    2016-01-01

    Pedestrian navigation systems (PNS) using foot-mounted MEMS inertial sensors use zero-velocity updates (ZUPTs) to reduce drift in navigation solutions and estimate inertial sensor errors. However, it is well known that ZUPTs cannot reduce all errors, especially as heading error is not observable. Hence, the position estimates tend to drift and even cyclic ZUPTs are applied in updated steps of the Extended Kalman Filter (EKF). This urges the use of other motion constraints for pedestrian gait and any other valuable heading reduction information that is available. In this paper, we exploit two more motion constraints scenarios of pedestrian gait: (1) walking along straight paths; (2) standing still for a long time. It is observed that these motion constraints (called “virtual sensor”), though considerably reducing drift in PNS, still need an absolute heading reference. One common absolute heading estimation sensor is the magnetometer, which senses the Earth’s magnetic field and, hence, the true heading angle can be calculated. However, magnetometers are susceptible to magnetic distortions, especially in indoor environments. In this work, an algorithm, called magnetic anomaly detection (MAD) and compensation is designed by incorporating only healthy magnetometer data in the EKF updating step, to reduce drift in zero-velocity updated INS. Experiments are conducted in GPS-denied and magnetically distorted environments to validate the proposed algorithms. PMID:27618056

  2. Summary report of mission acceleration measurements for Spacehab-01, STS-57 launched 21 June 1993

    NASA Technical Reports Server (NTRS)

    Finley, Brian; Grodsinsky, Carlos; Delombard, Richard

    1994-01-01

    The maiden voyage of the commercial Spacehab laboratory module onboard the STS-57 mission was integrated with several accelerometer packages, one of which was the Space Acceleration Measurement System (SAMS). The June 21st 1993, launch was the seventh successful mission for the Office of Life and Microgravity Sciences and Application's (OLMSA) SAMS unit. This flight was also complemented by a second accelerometer system. The Three Dimensional Microgravity Accelerometer (3-DMA), a Code C funded acceleration measurement system, offering an on-orbit residual calibration as a reference for the unit's four triaxial accelerometers. The SAMS accelerometer unit utilized three remote triaxial sensor heads mounted on the forward Spacehab module bulkhead and on one centrally located experiment locker door. These triaxial heads had filter cut-offs set to 5, 50, and 1000 Hz. The mission also included other experiment specific accelerometer packages in various locations.

  3. Vestibular system: the many facets of a multimodal sense.

    PubMed

    Angelaki, Dora E; Cullen, Kathleen E

    2008-01-01

    Elegant sensory structures in the inner ear have evolved to measure head motion. These vestibular receptors consist of highly conserved semicircular canals and otolith organs. Unlike other senses, vestibular information in the central nervous system becomes immediately multisensory and multimodal. There is no overt, readily recognizable conscious sensation from these organs, yet vestibular signals contribute to a surprising range of brain functions, from the most automatic reflexes to spatial perception and motor coordination. Critical to these diverse, multimodal functions are multiple computationally intriguing levels of processing. For example, the need for multisensory integration necessitates vestibular representations in multiple reference frames. Proprioceptive-vestibular interactions, coupled with corollary discharge of a motor plan, allow the brain to distinguish actively generated from passive head movements. Finally, nonlinear interactions between otolith and canal signals allow the vestibular system to function as an inertial sensor and contribute critically to both navigation and spatial orientation.

  4. Potential of pedestrian protection systems--a parameter study using finite element models of pedestrian dummy and generic passenger vehicles.

    PubMed

    Fredriksson, Rikard; Shin, Jaeho; Untaroiu, Costin D

    2011-08-01

    To study the potential of active, passive, and integrated (combined active and passive) safety systems in reducing pedestrian upper body loading in typical impact configurations. Finite element simulations using models of generic sedan car fronts and the Polar II pedestrian dummy were performed for 3 impact configurations at 2 impact speeds. Chest contact force, head injury criterion (HIC(15)), head angular acceleration, and the cumulative strain damage measure (CSDM(0.25)) were employed as injury parameters. Further, 3 countermeasures were modeled: an active autonomous braking system, a passive deployable countermeasure, and an integrated system combining the active and passive systems. The auto-brake system was modeled by reducing impact speed by 10 km/h (equivalent to ideal full braking over 0.3 s) and introducing a pitch of 1 degree and in-crash deceleration of 1 g. The deployable system consisted of a deployable hood, lifting 100 mm in the rear, and a lower windshield air bag. All 3 countermeasures showed benefit in a majority of impact configurations in terms of injury prevention. The auto-brake system reduced chest force in a majority of the configurations and decreased HIC(15), head angular acceleration, and CSDM in all configurations. Averaging all impact configurations, the auto-brake system showed reductions of injury predictors from 20 percent (chest force) to 82 percent (HIC). The passive deployable countermeasure reduced chest force and HIC(15) in a majority of configurations and head angular acceleration and CSDM in all configurations, although the CSDM decrease in 2 configurations was minimal. On average a reduction from 20 percent (CSDM) to 58 percent (HIC) was recorded in the passive deployable countermeasures. Finally, the integrated system evaluated in this study reduced all injury assessment parameters in all configurations compared to the reference situations. The average reductions achieved by the integrated system ranged from 56 percent (CSDM) to 85 percent (HIC). Both the active (autonomous braking) and passive deployable system studied had a potential to decrease pedestrian upper body loading. An integrated pedestrian safety system combining the active and passive systems increased the potential of the individual systems in reducing pedestrian head and chest loading.

  5. All-automatic swimmer tracking system based on an optimized scaled composite JTC technique

    NASA Astrophysics Data System (ADS)

    Benarab, D.; Napoléon, T.; Alfalou, A.; Verney, A.; Hellard, P.

    2016-04-01

    In this paper, an all-automatic optimized JTC based swimmer tracking system is proposed and evaluated on real video database outcome from national and international swimming competitions (French National Championship, Limoges 2015, FINA World Championships, Barcelona 2013 and Kazan 2015). First, we proposed to calibrate the swimming pool using the DLT algorithm (Direct Linear Transformation). DLT calculates the homography matrix given a sufficient set of correspondence points between pixels and metric coordinates: i.e. DLT takes into account the dimensions of the swimming pool and the type of the swim. Once the swimming pool is calibrated, we extract the lane. Then we apply a motion detection approach to detect globally the swimmer in this lane. Next, we apply our optimized Scaled Composite JTC which consists of creating an adapted input plane that contains the predicted region and the head reference image. This latter is generated using a composite filter of fin images chosen from the database. The dimension of this reference will be scaled according to the ratio between the head's dimension and the width of the swimming lane. Finally, applying the proposed approach improves the performances of our previous tracking method by adding a detection module in order to achieve an all-automatic swimmer tracking system.

  6. 49 CFR 572.17 - Neck.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline a... distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at time T as...

  7. 49 CFR 572.7 - Neck.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... paragraph (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline... the straight line distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at...

  8. 49 CFR 572.17 - Neck.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline a... distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at time T as...

  9. 49 CFR 572.17 - Neck.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline a... distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at time T as...

  10. 49 CFR 572.17 - Neck.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline a... distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at time T as...

  11. 49 CFR 572.17 - Neck.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline a... distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at time T as...

  12. 49 CFR 572.7 - Neck.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... paragraph (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline... the straight line distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at...

  13. 49 CFR 572.7 - Neck.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... paragraph (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline... the straight line distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at...

  14. 49 CFR 572.7 - Neck.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... paragraph (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline... the straight line distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at...

  15. 49 CFR 572.7 - Neck.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... paragraph (c) of this section, the head shall rotate in reference to the pendulum's longitudinal centerline... the straight line distance between (1) the position relative to the pendulum arm of the head center of gravity at time zero, and (2) the position relative to the pendulum arm of the head center of gravity at...

  16. Management Preparation and Training of Department Heads in ARL Libraries.

    ERIC Educational Resources Information Center

    Wittenbach, Stefanie A.; And Others

    1992-01-01

    A survey of cataloging and reference department heads in ARL (Association for Research Libraries) member libraries showed that both professional experience and management coursework play a part in a librarian's promotion to department head. It is suggested that library management will improve if libraries require formal management preparation and…

  17. Reference Values for Weight, Height, Head Circumference, and Body Mass Index in Turkish Children.

    PubMed

    Neyzi, Olcay; Bundak, Rüveyde; Gökçay, Gülbin; Günöz, Hülya; Furman, Andrzej; Darendeliler, Feyza; Baş, Firdevs

    2015-12-01

    This study aimed to integrate the existing updated reference standards for the growth of Turkish infants and children and to compare these values with World Health Organization (WHO) reference data, data from some European countries, and also with previous local data. Weight, height, and head circumference measurements were obtained on 2,391 boys and 2,102 girls who were regular attenders of a well child clinic and on 1,100 boys and 1,020 girls attending schools in relatively well-off districts in İstanbul. Mean number of measurements per child was 8.2±3.6 in the age group 0-5 years and 5.5±3.3 in the age group 6-18 years. All children were from well-to-do families and all were healthy. All measurements with the exception of measurements at birth, which were based on reported values, were done by trained personnel. The LMS method was used in the analyses and in the construction of the percentile charts. There is an increase in weight for age and body mass index values for age starting in prepubertal ages, indicating an increasing trend for obesity. Compared to WHO reference data, weight and height values in Turkish children were slightly higher in infants and in children younger than 5 years, while they showed similarity to those reported for children from Norway and Belgium. Head circumference values, which were slightly higher than the WHO references in the first 5 years, were comparable to the data on Belgian and Norwegian children in the first 9 years of life. At older ages, Turkish children showed higher values for head circumference. The relatively larger head circumference values were interpreted to reflect a genetic characteristic.

  18. The diagnostic yield of ultrasound of the head in healthy infants presenting with the clinical diagnosis of benign macrocrania.

    PubMed

    Naffaa, L; Rubin, M; Stamler, A C; Haddad, M; Saade, C

    2017-01-01

    To investigate the frequency of sonographic findings that required neurosurgical consultation for all referred outpatients suspected to have benign macrocrania (BMC). A retrospective review was performed from September 2011 until June 2015 for all outpatients referred to the ultrasound (US) department for BMC. Electronic medical records, US images, and reports were reviewed in conjunction with follow-up imaging. Each review consisted of gender, specialty of referring physician, first head circumference, head circumference at or closest to the time of the head US, the last head circumference, and any neurological issue prior to the US, at the time of US, or following the US, and clinical outcomes. Statistical analysis employed the Kruskal-Wallis rank sum test and Fischer's exact test (chi square test of independence) that compared normal/BMC patients from the patients requiring a neurosurgical consultation. One hundred and thirty (40.9%) had a normal head US, 181 patients (56.9%) had sonographic findings of BMC, and seven (2.2%) patients had an abnormal head US that required a neurosurgical consultation. Of the 181 patients with BMC, 23 underwent follow-up imaging with 22 patients having unchanged BMC or a normal head US and one patient developing mild ventriculomegaly that was stable on follow-up imaging. Three of the seven patients (1%) aged 1.8, 2.3, and 13.1 months with abnormal head US requiring neurosurgical consultation, had mild ventriculomegaly that was stable on follow-up imaging. Four of the seven patients (1.2%) that required neurosurgical consultation needed a neurosurgical procedure. Between the two US subgroups (normal and BMC), no statistical significance was noted regarding age of patient at US, head circumference at clinical and radiological presentation (p>0.05) except for the first head circumference clinically documented which demonstrated statistical significance (p<0.03). Short interval surveillance including head circumference and assessment for the development of bulging anterior fontanelle and neurological abnormalities may be more cost effective than US in the initial evaluation of patients clinically suspected to have BMC. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Cocaine intoxication

    MedlinePlus

    ... head, if head injury or bleeding is suspected ECG (electrocardiogram, to measure electrical activity in the heart) ... to amputation Alternative Names Intoxication - cocaine Images Electrocardiogram (ECG) References Aronson JK. Cocaine. In: Aronson JK, ed. ...

  20. Time-of-flight magnetic resonance angiography (TOF-MRA) of the normal equine head.

    PubMed

    Manso-Díaz, G; García-Real, M I; Casteleyn, C; San-Román, F; Taeymans, O

    2013-03-01

    Noncontrast magnetic resonance angiography (MRA) is widely used in human and small animal medicine. However, this technique has not yet been described in the horse, and compared to other angiographic techniques MRA could be more cost efficient and potentially safer. The aim of this study was to provide a comprehensive anatomical reference of the normal equine head vasculature using a noncontrast MRA technique, on both low- and high-field MRI. Five healthy adult horses were examined, 4 with a low-field magnet (0.23T) and the remaining one with a high-field magnet (1.5T). The magnetic resonance angiography sequence used was TOF (time-of-flight) 2D-MRA and CT images of a vascular corrosion cast were subsequently used as anatomical references. The MRA imaging protocol provided good visualisation of all major intra- and extracranial vessels down to a size of approximately 2 mm in diameter on both low- and high-field systems. This resulted in identification of vessels to the order of 3rd-4th branches of ramification. The visibility of the arteries was higher than of the veins, which showed lower signal intensity. Overall, MRA obtained with the high-field protocol provided better visualisation of the arteries, showing all the small arterial branches with a superior resolution. The use of a specific vascular sequence such as TOF 2D-MRA allows good visualisation of the equine head vasculature and eliminates the need for contrast media for MRA. Magnetic resonance angiography allows for visualisation of the vasculature of the equine head. Vessel morphology, symmetry and size can be evaluated and this may possibly play a role in preoperative planning or characterisation of diseases of the head, such as neoplasia or guttural pouch mycosis. © 2012 EVJ Ltd.

  1. NORTH PORTAL-HOT WATER CIRCULATION PUMP CALCULATION-SHOP BUILDING #5006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. Blackstone

    1996-01-25

    The purpose of this design analysis and calculation is to size a circulating pump for the service hot water system in the Shop Building 5006, in accordance with the Uniform Plumbing Code (Section 4.4.1) and U.S. Department of Energy Order 6430.1A-1540 (Section 4.4.2). The method used for the calculation is based on Reference 5.2. This consists of determining the total heat transfer from the service hot water system piping to the surrounding environment. The heat transfer is then used to define the total pumping capacity based on a given temperature change in the circulating hot water as it flows throughmore » the closed loop piping system. The total pumping capacity is used to select a pump model from manufacturer's literature. This established the head generation for that capacity and particular pump model. The total length of all hot water supply and return piping including fittings is then estimated from the plumbing drawings which defines the pipe friction losses that must fit within the available pump head. Several iterations may be required before a pump can be selected that satisfies the head-capacity requirements.« less

  2. Itching

    MedlinePlus

    ... and stings Parasites such as pinworm , body lice , head lice , and pubic lice Pityriasis rosea Psoriasis Rashes (may ... ill recently. Alternative Names Pruritus Images Allergic reactions Head lice Skin layers References Garg A, Bernhard JD. Pruritus. ...

  3. How directions of route descriptions influence orientation specificity: the contribution of spatial abilities.

    PubMed

    Meneghetti, Chiara; Muffato, Veronica; Varotto, Diego; De Beni, Rossana

    2017-03-01

    Previous studies found mental representations of route descriptions north-up oriented when egocentric experience (given by the protagonist's initial view) was congruent with the global reference system. This study examines: (a) the development and maintenance of representations derived from descriptions when the egocentric and global reference systems are congruent or incongruent; and (b) how spatial abilities modulate these representations. Sixty participants (in two groups of 30) heard route descriptions of a protagonist's moves starting from the bottom of a layout and headed mainly northwards (SN description) in one group, and headed south from the top (NS description, the egocentric view facing in the opposite direction to the canonical north) in the other. Description recall was tested with map drawing (after hearing the description a first and second time; i.e. Time 1 and 2) and South-North (SN) or North-South (NS) pointing tasks; and spatial objective tasks were administered. The results showed that: (a) the drawings were more rotated in NS than in SN descriptions, and performed better at Time 2 than at Time 1 for both types of description; SN pointing was more accurate than NS pointing for the SN description, while SN and NS pointing accuracy did not differ for the NS description; (b) spatial (rotation) abilities were related to recall accuracy for both types of description, but were more so for the NS ones. Overall, our results showed that the way in which spatial information is conveyed (with/without congruence between the egocentric and global reference systems) and spatial abilities influence the development and maintenance of mental representations.

  4. Quantitative Analysis Tools and Digital Phantoms for Deformable Image Registration Quality Assurance.

    PubMed

    Kim, Haksoo; Park, Samuel B; Monroe, James I; Traughber, Bryan J; Zheng, Yiran; Lo, Simon S; Yao, Min; Mansur, David; Ellis, Rodney; Machtay, Mitchell; Sohn, Jason W

    2015-08-01

    This article proposes quantitative analysis tools and digital phantoms to quantify intrinsic errors of deformable image registration (DIR) systems and establish quality assurance (QA) procedures for clinical use of DIR systems utilizing local and global error analysis methods with clinically realistic digital image phantoms. Landmark-based image registration verifications are suitable only for images with significant feature points. To address this shortfall, we adapted a deformation vector field (DVF) comparison approach with new analysis techniques to quantify the results. Digital image phantoms are derived from data sets of actual patient images (a reference image set, R, a test image set, T). Image sets from the same patient taken at different times are registered with deformable methods producing a reference DVFref. Applying DVFref to the original reference image deforms T into a new image R'. The data set, R', T, and DVFref, is from a realistic truth set and therefore can be used to analyze any DIR system and expose intrinsic errors by comparing DVFref and DVFtest. For quantitative error analysis, calculating and delineating differences between DVFs, 2 methods were used, (1) a local error analysis tool that displays deformation error magnitudes with color mapping on each image slice and (2) a global error analysis tool that calculates a deformation error histogram, which describes a cumulative probability function of errors for each anatomical structure. Three digital image phantoms were generated from three patients with a head and neck, a lung and a liver cancer. The DIR QA was evaluated using the case with head and neck. © The Author(s) 2014.

  5. Reliability and Normative Data for the Dynamic Visual Acuity Test for Vestibular Screening.

    PubMed

    Riska, Kristal M; Hall, Courtney D

    2016-06-01

    The purpose of this study was to determine reliability of computerized dynamic visual acuity (DVA) testing and to determine reference values for younger and older adults. A primary function of the vestibular system is to maintain gaze stability during head motion. The DVA test quantifies gaze stabilization with the head moving versus stationary. Commercially available computerized systems allow clinicians to incorporate DVA into their assessment; however, information regarding reliability and normative values of these systems is sparse. Forty-six healthy adults, grouped by age, with normal vestibular function were recruited. Each participant completed computerized DVA testing including static visual acuity, minimum perception time, and DVA using the NeuroCom inVision System. Testing was performed by two examiners in the same session and then repeated at a follow-up session 3 to 14 days later. Intraclass correlation coefficients (ICCs) were used to determine inter-rater and test-retest reliability. ICCs for inter-rater reliability ranged from 0.323 to 0.937 and from 0.434 to 0.909 for horizontal and vertical head movements, respectively. ICCs for test-retest reliability ranged from 0.154 to 0.856 and from 0.377 to 0.9062 for horizontal and vertical head movements, respectively. Overall, raw scores (left/right DVA and up/down DVA) were more reliable than DVA loss scores. Reliability of a commercially available DVA system has poor-to-fair reliability for DVA loss scores. The use of a convergence paradigm and not incorporating the forced choice paradigm may contribute to poor reliability.

  6. Pubic lice

    MedlinePlus

    ... humans. Other types of lice include: Body lice Head lice You are at greater risk for pubic lice ... Images Crab louse, female Pubic louse-male Crab lice Head louse and pubic louse References Diaz JH. Lice ( ...

  7. Growth charts for Australian children with achondroplasia.

    PubMed

    Tofts, Louise; Das, Sandeep; Collins, Felicity; Burton, Karen L O

    2017-08-01

    Achondroplasia is an autosomal dominant disorder, the most common genetic cause of short stature in humans. Reference curves for head circumference, weight, height, and BMI are needed in clinical practice but none exist for the Australian population. This study aimed to produce head circumference, height, weight, and BMI reference percentile curves for Australian children and adolescents with achondroplasia. Measurements of head circumference, height and weight taken at clinical visits were retrospectively extracted from the electronic medical record. Age was corrected for prematurity. Patients were excluded from head circumference analysis if they had significant neurosurgical complications and from the weight and BMI analysis when they had a clinical diagnosis of overweight. Measurements were available on 138 individuals (69 males and 69 females) taken between 1970 and 2015, with over 50% collected since 2005. A total of 3,352 data points were available. The LMS method was used to produce growth charts with estimated centiles (10, 25, 50, 75, and 90th) separately for males and females. For females birth weight was 3 kg (2.5-3.5 kg), birth length 48 cm (44-50 cm) and head circumference 37.5 cm (36-39 cm), adult height was 125 cm (116-132 cm), weight 42 kg (34-54 kg), and head circumference 58 cm (55.5-60.5 cm) all 50th centile (10-90th). For males birth weight was 3.5 kg (3-4 kg), length 49 cm (46-52 cm) and head circumference 38.5 cm (36-41 cm), adult height was 134 cm (125-141 cm), weight 41 kg (24.5-57 kg) and head circumference 61 cm (58-64 cm). The curves are similar to previously published reference data from the USA and have expected population wide variation from curves from an Argentinian population. Despite limitations of our curves for adolescents (12 years and older) due to data paucity, these Australian growth charts for children and adolescents with achondroplasia will be a useful reference in clinical practice. © 2017 Wiley Periodicals, Inc.

  8. Awake craniotomy using electromagnetic navigation technology without rigid pin fixation.

    PubMed

    Morsy, Ahmed A; Ng, Wai Hoe

    2015-11-01

    We report our institutional experience using an electromagnetic navigation system, without rigid head fixation, for awake craniotomy patients. The StealthStation® S7 AxiEM™ navigation system (Medtronic, Inc.) was used for this technique. Detailed preoperative clinical and neuropsychological evaluations, patient education and contrast-enhanced MRI (thickness 1.5mm) were performed for each patient. The AxiEM Mobile Emitter was typically placed in a holder, which was mounted to the operating room table, and a non-invasive patient tracker was used as the patient reference device. A monitored conscious sedation technique was used in all awake craniotomy patients, and the AxiEM Navigation Pointer was used for navigation during the procedure. This offers the same accuracy as optical navigation, but without head pin fixation or interference with intraoperative neurophysiological techniques and surgical instruments. The application of the electromagnetic neuronavigation technology without rigid head fixation during an awake craniotomy is accurate, and offers superior patient comfort. It is recommended as an effective adjunctive technique for the conduct of awake surgery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Using Stars to Align a Steered Laser System for Cosmic Ray Simulation

    NASA Astrophysics Data System (ADS)

    Krantz, Harry; Wiencke, Lawrence

    2016-03-01

    Ultra high energy cosmic rays (UHECRs) are the highest energy cosmic particles with kinetic energy above 1018eV . UHECRs are detected from the air shower of secondary particles and UV florescence that results from interaction with the atmosphere. A high power UV laser beam can be used to simulate the optical signature of a UHCER air shower. The Global Light System (GLS) is a planned network of ground-based light sources including lasers to support the planned space-based Extreme Universe Space Observatory (EUSO). A portable prototype GLS laser station has been constructed at the Colorado School of Mines. Currently the laser system uses reference targets on the ground but stars can be used to better align the beam by providing a complete hemisphere of targets. In this work, a CCD camera is used to capture images of known stars through the steering head optics. The images are analyzed to find the steering head coordinates of the target star. The true coordinates of the star are calculated from the location and time of observation. A universal adjustment for the steering head is determined from the differences between the two pairs of coordinates across multiple stars. This laser system prototype will also be used for preflight tests of the ESUO Super Pressure Balloon mission.

  10. ALLTEM System User’s Manual, Munitions Management Projects, ALLTEM Multi-Axis Electromagnetic Induction System Demonstration and Validation, Version 1.0

    DTIC Science & Technology

    2012-03-05

    Alarm button. Under the GPS frame are two smaller frames. On the left is a frame with buttons labeled Tractor Guidance and Acquisition Error... GPS ) and the Attitude Heading Reference System (AHRS) data. 5.2 Using the Data Acquisition Simulator Software The simulator and a practice set... acquisition for one polarity of the TX (33ms dead band for relay switching + 33 ms of waveforms). When the GPS is being used this is usually “1”, but may be

  11. Does Visual Performance Influence Head Impact Severity Among High School Football Athletes?

    PubMed

    Schmidt, Julianne D; Guskiewicz, Kevin M; Mihalik, Jason P; Blackburn, J Troy; Siegmund, Gunter P; Marshall, Stephen W

    2015-11-01

    To compare the odds of sustaining moderate and severe head impacts, rather than mild, between high school football players with high and low visual performance. Prospective quasi-experimental. Clinical Research Center/On-field. Thirty-seven high school varsity football players. Athletes completed the Nike SPARQ Sensory Station visual assessment before the season. Head impact biomechanics were captured at all practices and games using the Head Impact Telemetry System. Each player was classified as either a high or low performer using a median split for each of the following visual performance measures: visual clarity, contrast sensitivity, depth perception, near-far quickness, target capture, perception span, eye-hand coordination, go/no go, and reaction time. We computed the odds of sustaining moderate and severe head impacts against the reference odds of sustaining mild head impacts across groups of high and low performers for each of the visual performance measures. Players with better near-far quickness had increased odds of sustaining moderate [odds ratios (ORs), 1.27; 95% confidence intervals (CIs), 1.04-1.56] and severe head impacts (OR, 1.45; 95% CI, 1.05-2.01) as measured by Head Impact Technology severity profile. High and low performers were at equal odds on all other measures. Better visual performance did not reduce the odds of sustaining higher magnitude head impacts. Visual performance may play less of a role than expected for protecting against higher magnitude head impacts among high school football players. Further research is needed to determine whether visual performance influences concussion risk. Based on our results, we do not recommend using visual training programs at the high school level for the purpose of reducing the odds of sustaining higher magnitude head impacts.

  12. Validity and reliability of head posture measurement using Microsoft Kinect.

    PubMed

    Oh, Baek-Lok; Kim, Jongmin; Kim, Jongshin; Hwang, Jeong-Min; Lee, Jehee

    2014-11-01

    To investigate the validity and reliability of Microsoft Kinect-based head tracker (KHT) for measuring head posture. Considering the cervical range of motion (CROM) as a reference, one-dimensional and three-dimensional (1D and 3D) head postures of 12 normal subjects (28-58 years of age; 6 women and 6 men) were obtained using the KHT. The KHT was validated by Pearson's correlation coefficient and intraclass correlation (ICC) coefficient. Test-retest reliability of the KHT was determined by its 95% limit of agreement (LoA) with the Bland-Altman plot. Face recognition success rate was evaluated for each head posture. Measurements of 1D and 3D head posture performed using the KHT were very close to those of the CROM with correlation coefficients of 0.99 and 0.97 (p<0.05), respectively, as well as with an ICC of >0.99 and 0.98, respectively. The reliability tests of the KHT in terms of 1D and 3D head postures had 95% LoA angles of approximately ±2.5° and ±6.5°, respectively. The KHT showed good agreement with the CROM and relatively favourable test-retest reliability. Considering its high performance, convenience and low cost, KHT could be clinically used as a head posture-measuring system. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Low resolution brain electromagnetic tomography in a realistic geometry head model: a simulation study

    NASA Astrophysics Data System (ADS)

    Ding, Lei; Lai, Yuan; He, Bin

    2005-01-01

    It is of importance to localize neural sources from scalp recorded EEG. Low resolution brain electromagnetic tomography (LORETA) has received considerable attention for localizing brain electrical sources. However, most such efforts have used spherical head models in representing the head volume conductor. Investigation of the performance of LORETA in a realistic geometry head model, as compared with the spherical model, will provide useful information guiding interpretation of data obtained by using the spherical head model. The performance of LORETA was evaluated by means of computer simulations. The boundary element method was used to solve the forward problem. A three-shell realistic geometry (RG) head model was constructed from MRI scans of a human subject. Dipole source configurations of a single dipole located at different regions of the brain with varying depth were used to assess the performance of LORETA in different regions of the brain. A three-sphere head model was also used to approximate the RG head model, and similar simulations performed, and results compared with the RG-LORETA with reference to the locations of the simulated sources. Multi-source localizations were discussed and examples given in the RG head model. Localization errors employing the spherical LORETA, with reference to the source locations within the realistic geometry head, were about 20-30 mm, for four brain regions evaluated: frontal, parietal, temporal and occipital regions. Localization errors employing the RG head model were about 10 mm over the same four brain regions. The present simulation results suggest that the use of the RG head model reduces the localization error of LORETA, and that the RG head model based LORETA is desirable if high localization accuracy is needed.

  14. Diagnostic accuracy of referral criteria for head circumference to detect hydrocephalus in the first year of life.

    PubMed

    van Dommelen, Paula; Deurloo, Jacqueline A; Gooskens, Rob H; Verkerk, Paul H

    2015-04-01

    Increased head circumference is often the first and main sign leading to the diagnosis of hydrocephalus. Our aim is to investigate the diagnostic accuracy of referral criteria for head circumference to detect hydrocephalus in the first year of life. A reference group with longitudinal head circumference data (n = 1938) was obtained from the Social Medical Survey of Children Attending Child Health Clinics study. The case group comprised infants with hydrocephalus treated in a tertiary pediatric hospital who had not already been detected during pregnancy (n = 125). Head circumference data were available for 43 patients. Head circumference data were standardized according to gestational age-specific references. Sensitivity and specificity of a very large head circumference (>2.5 standard deviations on the growth chart) were, respectively, 72.1% (95% confidence interval [CI]: 56.3-84.7) and 97.1% (95% CI:96.2-97.8). These figures were, respectively, 74.4% (95% CI: 58.8-86.5) and 93.0% (95% CI:91.8-94.1) for a large head circumference (>2.0 standard deviation), and 76.7% (95% CI:61.4-88.2) and 96.5% (95% CI:95.6-97.3) for a very large head circumference and/or a very large (>2.5 standard deviation) progressive growth of head circumference. A very large head circumference and/or a very large progressive growth of head circumference shows the best diagnostic accuracy to detect hydrocephalus at an early stage. Gestational age-specific growth charts are recommended. Further improvements may be possible by taking into account parental head circumference. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Patient identification using a near-infrared laser scanner

    NASA Astrophysics Data System (ADS)

    Manit, Jirapong; Bremer, Christina; Schweikard, Achim; Ernst, Floris

    2017-03-01

    We propose a new biometric approach where the tissue thickness of a person's forehead is used as a biometric feature. Given that the spatial registration of two 3D laser scans of the same human face usually produces a low error value, the principle of point cloud registration and its error metric can be applied to human classification techniques. However, by only considering the spatial error, it is not possible to reliably verify a person's identity. We propose to use a novel near-infrared laser-based head tracking system to determine an additional feature, the tissue thickness, and include this in the error metric. Using MRI as a ground truth, data from the foreheads of 30 subjects was collected from which a 4D reference point cloud was created for each subject. The measurements from the near-infrared system were registered with all reference point clouds using the ICP algorithm. Afterwards, the spatial and tissue thickness errors were extracted, forming a 2D feature space. For all subjects, the lowest feature distance resulted from the registration of a measurement and the reference point cloud of the same person. The combined registration error features yielded two clusters in the feature space, one from the same subject and another from the other subjects. When only the tissue thickness error was considered, these clusters were less distinct but still present. These findings could help to raise safety standards for head and neck cancer patients and lays the foundation for a future human identification technique.

  16. Further Research on Heading in Text

    DTIC Science & Technology

    1989-12-28

    statement headings with low-ability children 10 5.0 Summary of the experiments 11 6.0 Concluding remarks 13 7.0 Acknowledgements 16 8.0 References 17... colour -coded headings as retrieval devices in electronic text, as well as the efficacy of ’running heads’. These, and other implications of research on...The following topics are discussed: * the time spent watching television " the people’s favourite programmes * attitudes to the BBC * attitudes to ITV

  17. Development of a frameless stereotactic radiosurgery system based on real-time 6D position monitoring and adaptive head motion compensation

    NASA Astrophysics Data System (ADS)

    Wiersma, Rodney D.; Wen, Zhifei; Sadinski, Meredith; Farrey, Karl; Yenice, Kamil M.

    2010-01-01

    Stereotactic radiosurgery delivers radiation with great spatial accuracy. To achieve sub-millimeter accuracy for intracranial SRS, a head ring is rigidly fixated to the skull to create a fixed reference. For some patients, the invasiveness of the ring can be highly uncomfortable and not well tolerated. In addition, placing and removing the ring requires special expertise from a neurosurgeon, and patient setup time for SRS can often be long. To reduce the invasiveness, hardware limitations and setup time, we are developing a system for performing accurate head positioning without the use of a head ring. The proposed method uses real-time 6D optical position feedback for turning on and off the treatment beam (gating) and guiding a motor-controlled 3D head motion compensation stage. The setup consists of a central control computer, an optical patient motion tracking system and a 3D motion compensation stage attached to the front of the LINAC couch. A styrofoam head cast was custom-built for patient support and was mounted on the compensation stage. The motion feedback of the markers was processed by the control computer, and the resulting motion of the target was calculated using a rigid body model. If the target deviated beyond a preset position of 0.2 mm, an automatic position correction was performed with stepper motors to adjust the head position via the couch mount motion platform. In the event the target deviated more than 1 mm, a safety relay switch was activated and the treatment beam was turned off. The feasibility of the concept was tested using five healthy volunteers. Head motion data were acquired with and without the use of motion compensation over treatment times of 15 min. On average, test subjects exceeded the 0.5 mm tolerance 86% of the time and the 1.0 mm tolerance 45% of the time without motion correction. With correction, this percentage was reduced to 5% and 2% for the 0.5 mm and 1.0 mm tolerances, respectively.

  18. Using a Cross Section to Train Veterinary Students To Visualize Anatomical Structures in Three Dimensions.

    ERIC Educational Resources Information Center

    Provo, Judy; Lamar, Carlton; Newby, Timothy

    2002-01-01

    Uses a cross section to enhance three-dimensional knowledge of the anatomy of a canine head. Involves (n=124) veterinary students dissecting the head and experimental groups also identifying structures on a cross section of the head. Reports a positive impact of this experience on participant students. (Contains 52 references.) (Author/YDS)

  19. Head-Mounted and Head-Up Display Glossary

    NASA Technical Reports Server (NTRS)

    Newman, Richard L.; Allen, J. Edwin W. (Technical Monitor)

    1997-01-01

    One of the problems in head-up and helmet-mounted display (HMD) literature has been a lack of standardization of words and abbreviations. Several different words have been used for the same concept; for example, flight path angle, flight path marker, velocity vector, and total velocity vector all refer to the same thing. In other cases, the same term has been used with two different meanings, such as binocular field-of-view which means the field-of-view visible to both left and right eyes according to some or the field-of-view visible to either the left or right eye or both according to others. Many of the terms used in HMD studies have not been well-defined. We need to have a common language to ensure that system descriptions are communicated. As an example, the term 'stabilized' has been widely used with two meanings. 'Roll-stabilized' has been used to mean a symbol which rotates to indicate the roll or bank of the aircraft. 'World-stabilized' and 'head-stabilized' have both been used to indicate symbols which move to remain fixed with respect to external objects. HMDs present unique symbology problems not found in HUDs. Foremost among these is the issue of maintaining spatial orientation of the symbols. All previous flight displays, round dial instruments, HDDs, and HUDs have been fixed in the cockpit. With the HMD, the flight display can move through a large angle. The coordinates use in transforming from the real-world to the aircraft to the HMD have not been consistently defined. This glossary contains terms relating to optics and vision, displays, and flight information, weapons and aircraft systems. Some definitions, such as Navigation Display, have been added to clarify the definitions for Primary Flight Display and Primary Flight Reference. A list of HUD/HMD related abbreviations is also included.

  20. The value of head circumference measurements after 36 months of age: a clinical report and review of practice patterns.

    PubMed

    James, Hector E; Perszyk, Anthony A; MacGregor, Teresa L; Aldana, Philipp R

    2015-08-01

    OBJECT The cranium is documented to grow from birth through adolescence. The standard of practice in primary care is measuring head circumference and plotting growth using curves that stop at 36 months. The authors report the importance of their experience with measuring head circumference in the child and same-sex parent beyond 36 months. METHODS In the University of Florida genetics and pediatric neurosurgery clinics, head circumference is measured and plotted on growth charts through 18 years of age. Circumference and rate of growth over time are compared with those of the same-sex parent. A diagnostic workup is initiated if there is a discrepancy with the patient's head circumference or if there is significant change in the growth rate of the cranium. RESULTS Between January 2004 and December 2007, the lead author examined 190 patients referred by pediatricians and/or pediatric subspecialists because of the concerns regarding head size of the child. Neuroimaging was performed in 70% of the patients prior to referral. None of the patients had their head size compared with that of their same-sex parent prior to referral. On assessing referring physician responses as to why the same-sex parents, head measurements were not pursued prior to imaging or referral to the specialists, the results were: 1) only have head circumference sheets to 36 months of age (n = 28); 2) the American Academy of Pediatrics does not recommend it (n = 3); and 3) the head stops growing at 36 months of age (n = 2). CONCLUSIONS Pediatricians and pediatric subspecialists need instruction on head circumference measurement in children from infancy through adolescence, and when indicated, in comparison with the head size of the same-sex parent. This measurement may be an effective and inexpensive assessment tool.

  1. MagnetoSperm: A microrobot that navigates using weak magnetic fields

    NASA Astrophysics Data System (ADS)

    Khalil, Islam S. M.; Dijkslag, Herman C.; Abelmann, Leon; Misra, Sarthak

    2014-06-01

    In this work, a propulsion system similar in motion to a sperm-cell is investigated. This system consists of a structure resembling a sperm-cell with a magnetic head and a flexible tail of 42 μm and 280 μm in length, respectively. The thickness, length, and width of this structure are 5.2 μm, 322 μm, and 42 μm, respectively. The magnetic head includes a 200 nm-thick cobalt-nickel layer. The cobalt-nickel layer provides a dipole moment and allows the flexible structure to align along oscillating weak (less than 5 mT) magnetic field lines, and hence generates a propulsion thrust force that overcomes the drag force. The frequency response of this system shows that the propulsion mechanism allows for swimming at an average speed of 158 ± 32 μm/s at alternating weak magnetic field of 45 Hz. In addition, we experimentally demonstrate controlled steering of the flexible structure towards reference positions.

  2. 29 CFR 1915.155 - Head protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Personal Protective Equipment...-2003, “American National Standard for Industrial Head Protection,” which is incorporated by reference...

  3. 29 CFR 1926.100 - Head protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Personal Protective and Life Saving Equipment... Industrial Head Protection,” incorporated by reference in § 1926.6; (ii) American National Standards...

  4. 29 CFR 1926.100 - Head protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Personal Protective and Life Saving Equipment... Industrial Head Protection,” incorporated by reference in § 1926.6; (ii) American National Standards...

  5. In vivo evaluation of wearable head impact sensors

    PubMed Central

    Wu, Lyndia C.; Nangia, Vaibhav; Bui, Kevin; Hammoor, Bradley; Kurt, Mehmet; Hernandez, Fidel; Kuo, Calvin; Camarillo, David B.

    2015-01-01

    Inertial sensors are commonly used to measure human head motion.(R1–3) Some sensors have been tested with dummy or cadaver experiments with mixed results, and methods to evaluate sensors in vivo are lacking. Here we present an in vivo(R3–10) method using high speed video to test teeth-mounted (mouthguard), soft tissue-mounted (skin patch), and headgear-mounted (skull cap) sensors during 6–13g(R1–20) sagittal soccer head impacts. Sensor coupling to the skull (R1–3) was quantified by displacement from an ear-canal reference. Mouthguard displacements were within video measurement error (<1mm), while the skin patch and skull cap displaced up to 4mm and 13mm from the ear-canal reference, respectively. We used the mouthguard, which had the least displacement from skull (R1–5), as the reference to assess 6-degree-of-freedom skin patch and skull cap measurements. Linear and rotational acceleration magnitudes were over-predicted by both the skin patch (with 120% NRMS error for amag, 290% for αmag(R1–6)) and the skull cap (320% NRMS error for amag, 500% for αmag(R1–6)). Such over-predictions were largely due to out-of-plane motion. To model sensor error, we found that in-plane skin patch acceleration peaks in the anterior-posterior direction could be modeled by an underdamped viscoelastic system. In summary, the mouthguard showed tighter skull coupling than the other sensor mounting approaches(R1–7). Furthermore, the in vivo methods presented are valuable for investigating skull acceleration sensor technologies. PMID:26289941

  6. Development of anticipatory orienting strategies and trajectory formation in goal-oriented locomotion.

    PubMed

    Belmonti, Vittorio; Cioni, Giovanni; Berthoz, Alain

    2013-05-01

    In goal-oriented locomotion, healthy adults generate highly stereotyped trajectories and a consistent anticipatory head orienting behaviour, both evidence of top-down, open-loop control. The aim of this study is to describe the typical development of anticipatory orienting strategies and trajectory formation. Our hypothesis is that full-blown anticipatory control requires advanced navigational skills. Twenty-six healthy subjects (14 children: 4-11 years; 6 adolescents: 13-17 years; 6 adults) were asked to walk freely towards one of the three visual targets, in a randomised order. Movement was captured via an optoelectronic system, with 15 body markers. The whole-body displacement, yaw orientation of head, trunk and pelvis, heading direction and foot placements were extracted. Head-heading anticipation, trajectory curvature, indexes of variability of trajectories, foot placements and kinematic profiles were studied. The mean head-heading anticipation time and trajectory curvature did not significantly differ among age groups. In children, however, head anticipation was more often lacking (χ2 = 9.55, p < 0.01), and there were significant intra- and inter-subject variations. Trajectory curvature was often very high in children, while it became consistently lower in adolescence (χ2 = 78.59, p < 10(-17)). The indexes of spatial and kinematic variability all followed a decreasing developmental trend (R (2) > 0.5, p < 0.0001). In conclusion, children under 11 do not perform curvilinear locomotor trajectories as adolescents and adults do. Anticipatory head orientation and trajectory formation develop in late childhood, well after gait maturation. Navigational skills, such as path planning and shifting from ego- to allocentric spatial reference frames, are proposed as necessary requisites for mature locomotor control.

  7. Development of optical surface-profiling instrumentation

    NASA Astrophysics Data System (ADS)

    Lin, Yao; Takacs, Peter Z.; Tsang, Thomas; Furenlid, Karen; Wang, Runwen

    1992-12-01

    A novel non-contact optical profiler described in this paper is designed and made for measuring the surface characteristics of optical parts. Measurements are based on a combination of an optical heterodyne technique and a precise phase measurement procedure without the need of a reference surface. A Zeeman-split He-Ne laser is employed as the light source which offers two common-path polarized beams. The frequency difference between the beams is 1.8 MHz. A special optical head is designed and fashioned as a beam splitter which contains a birefringent lens and an objective. The whole optical system is completely common- path. This allows the optical common-mode rejection technique to be applied in the system for minimizing the environmental effects in measurements such as air turbulence, vibrations and temperature variations. To keep the sample surface focused on the ordinary rays in the optical head, an astigmatic autofocus system is employed. A stepping micro-stepping system can move the optical head in the range of 25 mm with 0.1 micrometers resolution. A data acquisition system is made to control the auto-focus system, data receiving and analyses. This makes the measurement automatically while the sample is being scanned. The characteristics of the surface can be displayed on the computer screen. The theoretical and experimental analyses of the profiler are completed. The profiler measures samples with 1.1 angstroms height accuracy and 4 micrometers lateral resolution when a 40X objective is used in the optical head. The accuracy comparisons of the profiler with different objectives 5X, 10X, 20X, and 40X are shown in good agreement. The advantages of the present profiler are presented. Based on the autofocus system, the profiler optical system will be designed to mount on a large linear air-bearing slide, so that it is capable of scanning over a distance covering from 4 micrometers to 1 m.

  8. Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System.

    PubMed

    Song, Young Seop; Yang, Kyung Yong; Youn, Kibum; Yoon, Chiyul; Yeom, Jiwoon; Hwang, Hyeoncheol; Lee, Jehee; Kim, Keewon

    2016-08-01

    To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland-Altman plot with 95% limits of agreement (LoA). MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in -40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in -40° to 40° range were fair for all motions. Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.

  9. General equilibrium characteristics of a dual-lift helicopter system

    NASA Technical Reports Server (NTRS)

    Cicolani, L. S.; Kanning, G.

    1986-01-01

    The equilibrium characteristics of a dual-lift helicopter system are examined. The system consists of the cargo attached by cables to the endpoints of a spreader bar which is suspended by cables below two helicopters. Results are given for the orientation angles of the suspension system and its internal forces, and for the helicopter thrust vector requirements under general circumstances, including nonidentical helicopters, any accelerating or static equilibrium reference flight condition, any system heading relative to the flight direction, and any distribution of the load to the two helicopters. Optimum tether angles which minimize the sum of the required thrust magnitudes are also determined. The analysis does not consider the attitude degrees of freedom of the load and helicopters in detail, but assumes that these bodies are stable, and that their aerodynamic forces in equilibrium flight can be determined independently as functions of the reference trajectory. The ranges of these forces for sample helicopters and loads are examined and their effects on the equilibrium characteristics are given parametrically in the results.

  10. Virtual reality flight control display with six-degree-of-freedom controller and spherical orientation overlay

    NASA Technical Reports Server (NTRS)

    Beckman, Brian C. (Inventor)

    1995-01-01

    A virtual reality flight control system displays to the pilot the image of a scene surrounding a vehicle or pod having six degrees of freedom of acceleration or velocity control by the pilot and traveling through inertial space, the image itself including a superimposed figure providing the pilot an instant reference of orientation consisting of superimposed sets of geometric figures whose relative orientations provide the pilot an instantaneous feel or sense of orientation changes with respect to some fixed coordinate system. They include a first set of geometric figures whose orientations are fixed to the pilot's vehicle and a second set of geometric figures whose orientations are fixed with respect to a fixed or interstellar coordinate system. The first set of figures is a first set of orthogonal great circles about the three orthogonal axes of the flight vehicle or pod and centered at and surrounding the pilot's head, while the second set of figures is a second set of orthogonal great circles about the three orthogonal axes of a fixed or interstellar coordinate system, also centered at and surrounding the pilot's head.

  11. Stirling Space Engine Program. Volume 2; Appendixes A, B, C and D

    NASA Technical Reports Server (NTRS)

    Dhar, Manmohan

    1999-01-01

    The objective of this program was to develop the technology necessary for operating Stirling power converters in a space environment and to demonstrate this technology in full-scale engine tests. Volume 2 of the report includes the following appendices: Appendix A: Heater Head Development (Starfish Heater Head Program, 1/10th Segment and Full-Scale Heat Pipes, and Sodium Filling and Processing); Appendix B: Component Test Power Converter (CTPC) Component Development (High-temperature Organic Materials, Heat Exchanger Fabrication, Beryllium Issues, Sodium Issues, Wear Couple Tests, Pressure Boundary Penetrations, Heating System Heaters, and Cooler Flow Test); Appendix C: Udimet Testing (Selection of the Reference Material for the Space Stirling Engine Heater Head, Udimet 720LI Creep Test Result Update, Final Summary of Space Stirling Endurance Engine Udimet 720L1 Fatigue Testing Results, Udimet 720l1 Weld Development Summary, and Udimet 720L1 Creep Test Final Results Summary), and Appendix D: CTPC Component Development Photos.

  12. Colombian reference growth curves for height, weight, body mass index and head circumference.

    PubMed

    Durán, Paola; Merker, Andrea; Briceño, Germán; Colón, Eugenia; Line, Dionne; Abad, Verónica; Del Toro, Kenny; Chahín, Silvia; Matallana, Audrey Mary; Lema, Adriana; Llano, Mauricio; Céspedes, Jaime; Hagenäs, Lars

    2016-03-01

    Published Growth studies from Latin America are limited to growth references from Argentina and Venezuela. The aim of this study was to construct reference growth curves for height, weight, body mass index (BMI) and head circumference of Colombian children in a format that is useful for following the growth of the individual child and as a tool for public health. Prospective measurements from 27 209 Colombian children from middle and upper socio-economic level families were processed using the generalised additive models for location, scale and shape (GAMLSS). Descriptive statistics for length and height, weight, BMI and head circumference for age are given as raw and smoothed values. Final height was 172.3 cm for boys and 159.4 cm for girls. Weight at 18 years of age was 64.0 kg for boys and 54 kg for girls. Growth curves are presented in a ± 3 SD format using logarithmic axes. The constructed reference growth curves are a start for following secular trends in Colombia and are also in the presented layout an optimal clinical tool for health care. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  13. Camera pose estimation to improve accuracy and reliability of joint angles assessed with attitude and heading reference systems.

    PubMed

    Lebel, Karina; Hamel, Mathieu; Duval, Christian; Nguyen, Hung; Boissy, Patrick

    2018-01-01

    Joint kinematics can be assessed using orientation estimates from Attitude and Heading Reference Systems (AHRS). However, magnetically-perturbed environments affect the accuracy of the estimated orientations. This study investigates, both in controlled and human mobility conditions, a trial calibration technic based on a 2D photograph with a pose estimation algorithm to correct initial difference in AHRS Inertial reference frames and improve joint angle accuracy. In controlled conditions, two AHRS were solidly affixed onto a wooden stick and a series of static and dynamic trials were performed in varying environments. Mean accuracy of relative orientation between the two AHRS was improved from 24.4° to 2.9° using the proposed correction method. In human conditions, AHRS were placed on the shank and the foot of a participant who performed repeated trials of straight walking and walking while turning, varying the level of magnetic perturbation in the starting environment and the walking speed. Mean joint orientation accuracy went from 6.7° to 2.8° using the correction algorithm. The impact of starting environment was also greatly reduced, up to a point where one could consider it as non-significant from a clinical point of view (maximum mean difference went from 8° to 0.6°). The results obtained demonstrate that the proposed method improves significantly the mean accuracy of AHRS joint orientation estimations in magnetically-perturbed environments and can be implemented in post processing of AHRS data collected during biomechanical evaluation of motion. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Summary Report of Mission Acceleration Measurements for STS-62, Launched 4 March 1994

    NASA Technical Reports Server (NTRS)

    Rogers, Melissa J. B.; Delombard, Richard

    1994-01-01

    The second mission of the United States Microgravity Payload on-board the STS-62 mission was supported with three accelerometer instruments: the Orbital Acceleration Research Experiment (OARE) and two units of the Space Acceleration Measurements System (SAMS). The March 4, 1994 launch was the fourth successful mission for OARE and the ninth successful mission for SAMS. The OARE instrument utilizes a sensor for very low frequency measurements below one Hertz. The accelerations in this frequency range are typically referred to as quasisteady accelerations. One of the SAMS units had two remote triaxial sensor heads mounted on the forward MPESS structure between two furnance experiments, MEPHISTO and AADSF. These triaxial heads had low-pass filter cut-off frequencies at 10 and 25 Hz. The other SAMS unit utilized three remote triaxial sensor heads. Two of the sensor heads were mounted on the aft MPESS structure between the two experiments IDGE and ZENO. These triaxial heads had low-pass filter cut-off frequencies at 10 and 25 Hz. The third sensor head was mounted on the thermostat housing inside the IDGE experiment container. This triaxial head had a low-pass filter cut-off frequency at 5 Hz. This report is prepared to furnish interested experiment investigators with a guide to evaluating the acceleration environment during STS-62 and as a means of identifying areas which require further study. To achieve this purpose, various pieces of information are included, such as an overview of the STS-62 mission, a description of the accelerometer system flown on STS-62, some specific analysis of the accelerometer data in relation to the various mission activities, and an overview of the low-gravity environment during the entire mission. An evaluation form is included at the end of the report to solicit users' comments about the usefulness of this series of reports.

  15. Clause Structure in Old English: Evidence from Negative Concord.

    ERIC Educational Resources Information Center

    Haeberli, Eric; Haegeman, Liliane

    1995-01-01

    This paper deals with the clause structure of Old English. It is argued that the clause structure of Old English contains a head-initial functional projection whose head can be the landing site of verb movement in subordinate clauses. (41 references) (JL)

  16. SU-E-I-06: Measurement of Skin Dose from Dental Cone-Beam CT Scans.

    PubMed

    Akyalcin, S; English, J; Abramovitch, K; Rong, J

    2012-06-01

    To directly measure skin dose using point-dosimeters from dental cone-beam CT (CBCT) scans. To compare the results among three different dental CBCT scanners and compare the CBCT results with those from a conventional panoramic and cephalomic dental imaging system. A head anthropomorphic phantom was used with nanoDOT dosimeters attached to specified anatomic landmarks of selected radiosensitive tissues of interest. To ensure reliable measurement results, three dosimeters were used for each location. The phantom was scanned under various modes of operation and scan protocols for typical dental exams on three dental CBCT systems plus a conventional dental imaging system. The Landauer OSL nanoDOT dosimeters were calibrated under the same imaging condition as the head phantom scan protocols, and specifically for each of the imaging systems. Using nanoDOT dosimeters, skin doses at several positions on the surface of an adult head anthropomorphic phantom were measured for clinical dental imaging. The measured skin doses ranged from 0.04 to 4.62mGy depending on dosimeter positions and imaging systems. The highest dose location was at the parotid surface for all three CBCT scanners. The surface doses to the locations of the eyes were ∼4.0mGy, well below the 500mGy threshold for possibly causing cataract development. The results depend on x-ray tube output (kVp and mAs) and also are sensitive to SFOV. Comparing to the conventional dental imaging system operated in panoramic and cephalometric modes, doses from all three CBCT systems were at least an order of magnitude higher. No image artifact was caused by presence of nanoDOT dosimeters in the head phantom images. Direct measurements of skin dose using nanoDOT dosimeters provided accurate skin dose values without any image artifacts. The results of skin dose measurements serve as dose references in guiding future dose optimization efforts in dental CBCT imaging. © 2012 American Association of Physicists in Medicine.

  17. Analytical Bibliography for Water Supply and Conservation Techniques.

    DTIC Science & Technology

    1982-01-01

    effective due to rapidly increasing costs of water and wastewater services from centralized systems. The report may be used as a primary reference for...conservation kit. Each kit contained a toilet water dam, a plastic shower-head restrictor, and a packet of vegetable dye tablets to detect leaks from toilet...water in the 50 sub-basins of the North Atlantic Region (NAR) of the United States. The water-flow requirements (water demands) were disintegrated by

  18. Reference Collection Development Policy. Penfield Library, State University of New York College at Oswego.

    ERIC Educational Resources Information Center

    Judd, Blanche; And Others

    Intended for use by the head of reference and subject-area bibliographers at Penfield Library, this document provides guidelines for the selection and evaluation of titles for the 25,000 volume reference collection at this primarily undergraduate institution. The reference collection also supports the general information needs of both the college…

  19. Single photon emission tomography in neurological studies: Instrumentation and clinical applications

    NASA Astrophysics Data System (ADS)

    Nikkinen, Paivi Helena

    One triple head and two single head gamma camera systems were used for single photon emission tomography (SPET) imaging of both patients and brain phantoms. Studies with an anatomical brain phantom were performed for evaluation of reconstruction and correction methods in brain perfusion SPET studies. The use of the triple head gamma camera system resulted in a significant increase in image contrast and resolution. This was mainly due to better imaging geometry and the use of a high resolution collimator. The conventional Chang attenuation correction was found suitable for the brain perfusion studies. In the brain perfusion studies region of interest (ROI) based semiquantitation methods were used. A ROI map based on anatomical areas was used in 70 elderly persons (age range 55-85 years) without neurological diseases and in patients suffering from encephalitis or having had a cardiac arrest. Semiquantitative reference values are presented. For the 14 patients with encephalitis the right-to-left side differences were calculated. Defect volume indexes were calculated for 64 patients with brain infarcts. For the 30 cardiac arrest patients the defect percentages and the anteroposterior ratios were used for semiquantitation. It is concluded that different semiquantitation methods are needed for the various patient groups. Age-related reference values will improve the interpretation of SPET data. For validation of the basal ganglia receptor studies measurements were performed using a cylindrical and an anatomical striatal phantom. In these measurements conventional and transmission imaging based non-uniform attenuation corrections were compared. A calibration curve was calculated for the determination of the specific receptor uptake ratio. In the phantom studies using the triple head camera the uptake ratio obtained from simultaneous transmission-emission protocol (STEP) acquisition and iterative reconstruction was closest to the true activity ratio. Conventional acquisition and uniform Chang attenuation correction gave 40% lower values. The effect of dual window scatter correction was also measured. In conventional reconstruction dual window scatter correction increased the uptake ratios when using a single head camera, but when using the triple head camera this correction did not have a significant effect on the ratios. Semiquantitative values for striatal 123I-labelled β-carbomethoxy-3β- (4-iodophenyl)tropane (123I-βCIT) dopamine transporter uptake in 20 adults (mean age 52 +/- 15 years) are presented. The mean basal ganglia to cerebellum ratio was 6.5 +/- 0.9 and the mean caudatus to putamen ratio was 1.2. The registration of brain SPET and magnetic resonance (MR) studies provides the necessary anatomical information for determination of the ROIs. A procedure for registration and simultaneous display of brain SPET and MR images based on six external skin markers is presented. The usefulness of this method was demonstrated in selected patients. The registration accuracy was determined for single and triple head gamma camera systems using brain phantom and simulation studies. The registration residual for three internal test markers was calculated using 4 to 13 external markers in the registration. For 6 external markers, as used in the registration in the patient studies, the mean RMS residuals of the test markers for the single head camera and the triple head camera were 3.5 mm and 3.2 mm, respectively. According to the simulation studies the largest inaccuracy is due mainly to the spatial resolution of SPET. The use of six markers, as in the patient studies, is adequate for accurate registration.

  20. Analysis of posture and eye movement responses to Coriolis stimulation under 1 G and microgravity conditions.

    PubMed

    Sekine, Motoki; Takahashi, Masahiro; Iida, Masahiro

    2009-12-20

    To detect the effect of microgravity on vestibular responses, we conducted Coriolis stimulation experiments at 1 G and μ G. Five men with vision occluded were asked to tilt their head forward while rotating at 100 degrees/sec. Postural changes were recorded by a 3D linear accelerometer, and the distance of upper body movement was derived from recordings of linear acceleration. Eye movements were recorded by a CCD camera. For a second period after commencing head tilt, the upper body moved 10 cm in the direction of inertia input at 1 G, but it moved to the opposite direction at μ G, i.e., 4 cm in the direction of inertia force. Nystagmus peak slow-phase velocity immediately after head tilt and its attenuation process did not differ between 1 G and μ G. The strength of movement sensation and the severity of motion sickness were far weaker at μ G than at 1 G. It was concluded that inertia input is valid to induce postural and sensation responses only when the external reference is given Z axis by gravity. Vestibular ocular response may be maintained at μ G because the head reference is valid even after the external reference becomes arbitrary.

  1. Selected Reference Books of 1999.

    ERIC Educational Resources Information Center

    McIlvaine, Eileen

    2000-01-01

    Presents annotated bibliographies of a selection of recent scholarly and general reference works under the subject headings of publishing, periodical indexes, philosophy and religion, literature, music, art, photography, social sciences, business, history, and new editions. (LRW)

  2. Adiabatic diesel engine component development: Reference engine for on-highway applications

    NASA Technical Reports Server (NTRS)

    Hakim, Nabil S.

    1986-01-01

    The main objectives were to select an advanced low heat rejection diesel reference engine (ADRE) and to carry out systems analysis and design. The ADRE concept selection consisted of: (1) rated point performance optimization; (2) study of various exhaust energy recovery scenarios; (3) components, systems and engine configuration studies; and (4) life cycle cost estimates of the ADRE economic worth. The resulting ADRE design proposed a reciprocator with many advanced features for the 1995 technology demonstration time frame. These included ceramic air gap insulated hot section structural components, high temperature tribology treatments, nonmechanical (camless) valve actuation systems, and elimination of the cylinder head gasket. ADRE system analysis and design resulted in more definition of the engine systems. These systems include: (1) electro-hydraulic valve actuation, (2) electronic common rail injection system; (3) engine electronic control; (4) power transfer for accessory drives and exhaust energy recovery systems; and (5) truck installation. Tribology and performance assessments were also carried out. Finite element and probability of survival analyses were undertaken for the ceramic low heat rejection component.

  3. Reference curves of birth weight, length, and head circumference for gestational ages in Yogyakarta, Indonesia.

    PubMed

    Haksari, Ekawaty L; Lafeber, Harrie N; Hakimi, Mohammad; Pawirohartono, Endy P; Nyström, Lennarth

    2016-11-21

    The birth weight reference curve to estimate the newborns at risk in need of assessment and monitoring has been established. The previous reference curves from Indonesia, approximately 8 years ago, were based on the data collected from teaching hospitals only with limited gestational ages. The aims of the study were to update the reference curves for birth weight, supine length and head circumference for Indonesia, and to compare birth weight curves of boys and girls, first child and later children, and the ones in the previous studies. Data were extracted from the Maternal-Perinatal database between 1998-2007. Only live singletons with recorded gestational ages of 26 to 42 weeks and the exact time of admission to the neonatal facilities delivered or referred within 24 h of age to Sardjito Hospital, five district hospitals and five health centers in Yogyakarta Special Territory were included. Newborns with severely ill conditions, congenital anomaly and chromosomal abnormality were excluded. Smoothening of the curves was accomplished using a third-order polynomial equation. Our study included 54,599 singleton live births. Growth curves were constructed for boys (53.3%) and girls (46.7%) for birth weight, supine length, and head circumference. At term, mean birth weight for each gestational age of boys was significantly higher than that of girls. While mean birth weight for each gestational age of first-born-children, on the other hand was significantly lower than that of later-born-children. The mean birth weight was lower than that of Lubchenco's study. Compared with the previous Indonesian study by Alisyahbana, no differences were observed for the aterm infants, but lower mean birth weight was observed in preterm infants. Updated neonatal reference curves for birth weight, supine length and head circumference are important to classify high risk newborns in specific area and to identify newborns requiring attention.

  4. Doing Our Homework: A Pre-Employment Screening Checklist for Better Head Start Hiring.

    ERIC Educational Resources Information Center

    McSherry, Jim; Caruso, Karen; Cagnetta, Mary

    1999-01-01

    Provides a checklist for screening potential Head Start employees. Components include checks for criminal record, credit history, motor vehicle records, social security number tracing, previous address research, education verification, work and personal reference interview, and professional license verification. (KB)

  5. Age-specific MRI brain and head templates for healthy adults from 20 through 89 years of age

    PubMed Central

    Fillmore, Paul T.; Phillips-Meek, Michelle C.; Richards, John E.

    2015-01-01

    This study created and tested a database of adult, age-specific MRI brain and head templates. The participants included healthy adults from 20 through 89 years of age. The templates were done in five-year, 10-year, and multi-year intervals from 20 through 89 years, and consist of average T1W for the head and brain, and segmenting priors for gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). It was found that age-appropriate templates provided less biased tissue classification estimates than age-inappropriate reference data and reference data based on young adult templates. This database is available for use by other investigators and clinicians for their MRI studies, as well as other types of neuroimaging and electrophysiological research.1 PMID:25904864

  6. Magnetic heading reference

    NASA Technical Reports Server (NTRS)

    Garner, H. D. (Inventor)

    1977-01-01

    This invention employs a magnetometer as a magnetic heading reference for a vehicle such as a small aircraft. The magnetometer is mounted on a directional dial in the aircraft in the vicinity of the pilot such that it is free to turn with the dial about the yaw axis of the aircraft. The invention includes a circuit for generating a signal proportional to the northerly turning error produced in the magnetometer due to the vertical component of the earth's magnetic field. This generated signal is then subtracted from the output of the magnetometer to compensate for the northerly turning error.

  7. Laser-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

    NASA Technical Reports Server (NTRS)

    Wells, Dennis L. (Inventor); Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1995-01-01

    The invention relates generally to systems for determining the range of an object from a reference point and, in one embodiment, to laser-directed ranging systems useful in telerobotics applications. Digital processing techniques are employed which minimize the complexity and cost of the hardware and software for processing range calculations, thereby enhancing the commercial attractiveness of the system for use in relatively low-cost robotic systems. The system includes a video camera for generating images of the target, image digitizing circuitry, and an associated frame grabber circuit. The circuit first captures one of the pairs of stereo video images of the target, and then captures a second video image of the target as it is partly illuminated by the light beam, suitably generated by a laser. The two video images, taken sufficiently close together in time to minimize camera and scene motion, are converted to digital images and then compared. Common pixels are eliminated, leaving only a digital image of the laser-illuminated spot on the target. Mw centroid of the laser illuminated spot is dm obtained and compared with a predetermined reference point, predetermined by design or calibration, which represents the coordinate at the focal plane of the laser illumination at infinite range. Preferably, the laser and camera are mounted on a servo-driven platform which can be oriented to direct the camera and the laser toward the target. In one embodiment the platform is positioned in response to movement of the operator's head. Position and orientation sensors are used to monitor head movement. The disparity between the digital image of the laser spot and the reference point is calculated for determining range to the target. Commercial applications for the system relate to active range-determination systems, such as those used with robotic systems in which it is necessary to determine the, range to a workpiece or object to be grasped or acted upon by a robot arm end-effector in response to commands generated by an operator. In one embodiment, the system provides a real-time image of the target for the operator as the robot approaches the object. The system is also adapted for use in virtual reality systems in which a remote object or workpiece is to be acted upon by a remote robot arm or other mechanism controlled by an operator.

  8. Distance Education and Virtual Reference: Where Are We Headed?

    ERIC Educational Resources Information Center

    Coffman, Steve

    2001-01-01

    Discusses changes in distance education and considers the resulting need for new types of library services. Topics include new Web-based contact center software; how to conduct virtual reference interviews; online reference service; the role of the physical library; staffing changes; and future possibilities, including impacts on costs of library…

  9. Jewish Studies: A Guide to Reference Sources.

    ERIC Educational Resources Information Center

    McGill Univ., Montreal (Quebec). McLennan Library.

    An annotated bibliography to the reference sources for Jewish Studies in the McLennan Library of McGill University (Canada) is presented. Any titles in Hebrew characters are listed by their transliterated equivalents. There is also a list of relevant Library of Congress Subject Headings. General reference sources listed are: encyclopedias,…

  10. Ipsilateral wrist-ankle movements in the sagittal plane encoded in extrinsic reference frame.

    PubMed

    Muraoka, Tetsuro; Ishida, Yuki; Obu, Takashi; Crawshaw, Larry; Kanosue, Kazuyuki

    2013-04-01

    When performing oscillatory movements of two joints in the sagittal plane, there is a directional constraint for performing such movements. Previous studies could not distinguish whether the directional constraint reflected movement direction encoded in the extrinsic (outside the body) reference frame or in the intrinsic (the participants' torso/head) reference frame since participants performed coordinated movements in a sitting position where the torso/head was stationary relative to the external world. In order to discern the reference frame in the present study, participants performed paced oscillatory movements of the ipsilateral wrist and ankle in the sagittal plane in a standing position so that the torso/head moved relative to the external world. The coordinated movements were performed in one of two modes of coordination, moving the hand upward concomitant with either ankle plantarflexion or ankle dorsiflexion. The same directional mode relative to extrinsic space was more stable and accurate as compared with the opposite directional mode. When forearm position was changed from the pronated position to the supinated position, similar results were obtained, indicating that the results were independent of a particular coupling of muscles. These findings suggest that the directional constraint on ipsilateral joints movements in the sagittal plane reflects movement direction encoded in the extrinsic reference frame. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  11. The image-interpretation-workstation of the future: lessons learned

    NASA Astrophysics Data System (ADS)

    Maier, S.; van de Camp, F.; Hafermann, J.; Wagner, B.; Peinsipp-Byma, E.; Beyerer, J.

    2017-05-01

    In recent years, professionally used workstations got increasingly complex and multi-monitor systems are more and more common. Novel interaction techniques like gesture recognition were developed but used mostly for entertainment and gaming purposes. These human computer interfaces are not yet widely used in professional environments where they could greatly improve the user experience. To approach this problem, we combined existing tools in our imageinterpretation-workstation of the future, a multi-monitor workplace comprised of four screens. Each screen is dedicated to a special task in the image interpreting process: a geo-information system to geo-reference the images and provide a spatial reference for the user, an interactive recognition support tool, an annotation tool and a reporting tool. To further support the complex task of image interpreting, self-developed interaction systems for head-pose estimation and hand tracking were used in addition to more common technologies like touchscreens, face identification and speech recognition. A set of experiments were conducted to evaluate the usability of the different interaction systems. Two typical extensive tasks of image interpreting were devised and approved by military personal. They were then tested with a current setup of an image interpreting workstation using only keyboard and mouse against our image-interpretationworkstation of the future. To get a more detailed look at the usefulness of the interaction techniques in a multi-monitorsetup, the hand tracking, head pose estimation and the face recognition were further evaluated using tests inspired by everyday tasks. The results of the evaluation and the discussion are presented in this paper.

  12. Spacecraft attitude calibration/verification baseline study

    NASA Technical Reports Server (NTRS)

    Chen, L. C.

    1981-01-01

    A baseline study for a generalized spacecraft attitude calibration/verification system is presented. It can be used to define software specifications for three major functions required by a mission: the pre-launch parameter observability and data collection strategy study; the in-flight sensor calibration; and the post-calibration attitude accuracy verification. Analytical considerations are given for both single-axis and three-axis spacecrafts. The three-axis attitudes considered include the inertial-pointing attitudes, the reference-pointing attitudes, and attitudes undergoing specific maneuvers. The attitude sensors and hardware considered include the Earth horizon sensors, the plane-field Sun sensors, the coarse and fine two-axis digital Sun sensors, the three-axis magnetometers, the fixed-head star trackers, and the inertial reference gyros.

  13. ED07-0210-3

    NASA Image and Video Library

    2007-09-13

    The instruments that make up the Ames Autonomous Module Scanner (AMS) that provided precise thermal-infrared imaging during the Western States Fire Mission in 2007 are detailed in this photo of the AMS as mounted on Ikhana's pod tray. The large foil-covered foam-insulated box at left covers the pressure vessel containing the data system computers and other electronics. The round white-topped assembly is the scan head, including the scan mirror, folded telescope, blackbody references, spectrometer and detectors. Two pressure boxes visible at the forward end of the tray contain the Applanix POS/AV precision navigation subsystem (black) and the power distributor including circuit breakers and ancillary wiring, scan motor controller and the blackbody reference temperature controller (blue).

  14. Selected Reference Books of 1998-99.

    ERIC Educational Resources Information Center

    McIlvaine, Eileen

    1999-01-01

    Presents an annotated bibliography of selected reference books published between 1998 and 1999 under subject headings for biography, journalism, mythology, languages and literature, architecture and city planning, political science, economics, history, and new editions and supplements. (LRW)

  15. Lateral Load Testing of the Advanced Stirling Convertor (ASC-E2) Heater Head

    NASA Technical Reports Server (NTRS)

    Cornell, Peggy A.; Krause, David L.; Davis, Glen; Robbie, Malcolm G.; Gubics, David A.

    2010-01-01

    Free-piston Stirling convertors are fundamental to the development of NASA s next generation of radioisotope power system, the Advanced Stirling Radioisotope Generator (ASRG). The ASRG will use General Purpose Heat Source (GPHS) modules as the energy source and Advanced Stirling Convertors (ASCs) to convert heat into electrical energy, and is being developed by Lockheed Martin under contract to the Department of Energy. Achieving flight status mandates that the ASCs satisfy design as well as flight requirements to ensure reliable operation during launch. To meet these launch requirements, GRC performed a series of quasi-static mechanical tests simulating the pressure, thermal, and external loading conditions that will be experienced by an ASC-E2 heater head assembly. These mechanical tests were collectively referred to as "lateral load tests" since a primary external load lateral to the heater head longitudinal axis was applied in combination with the other loading conditions. The heater head was subjected to the operational pressure, axial mounting force, thermal conditions, and axial and lateral launch vehicle acceleration loadings. To permit reliable prediction of the heater head s structural performance, GRC completed Finite Element Analysis (FEA) computer modeling for the stress, strain, and deformation that will result during launch. The heater head lateral load test directly supported evaluation of the analysis and validation of the design to meet launch requirements. This paper provides an overview of each element within the test and presents assessment of the modeling as well as experimental results of this task.

  16. Lateral Load Testing of the Advanced Stirling Convertor (ASC-E2) Heater Head

    NASA Technical Reports Server (NTRS)

    Cornell, Peggy A.; Krause, David L.; Davis, Glen; Robbie, Malcolm G.; Gubics, David A.

    2011-01-01

    Free-piston Stirling convertors are fundamental to the development of NASA s next generation of radioisotope power system, the Advanced Stirling Radioisotope Generator (ASRG). The ASRG will use General Purpose Heat Source (GPHS) modules as the energy source and Advanced Stirling Convertors (ASCs) to convert heat into electrical energy, and is being developed by Lockheed Martin under contract to the Department of Energy. Achieving flight status mandates that the ASCs satisfy design as well as flight requirements to ensure reliable operation during launch. To meet these launch requirements, GRC performed a series of quasi-static mechanical tests simulating the pressure, thermal, and external loading conditions that will be experienced by an ASC-E2 heater head assembly. These mechanical tests were collectively referred to as "lateral load tests" since a primary external load lateral to the heater head longitudinal axis was applied in combination with the other loading conditions. The heater head was subjected to the operational pressure, axial mounting force, thermal conditions, and axial and lateral launch vehicle acceleration loadings. To permit reliable prediction of the heater head s structural performance, GRC completed Finite Element Analysis (FEA) computer modeling for the stress, strain, and deformation that will result during launch. The heater head lateral load test directly supported evaluation of the analysis and validation of the design to meet launch requirements. This paper provides an overview of each element within the test and presents assessment of the modeling as well as experimental results of this task.

  17. Lateral Load Testing of the Advanced Stirling Convertor (ASC-E2) Heater Head

    NASA Technical Reports Server (NTRS)

    Cornell, Peggy A.; Krause, David L.; Davis, Glen; Robbie, Malcolm G.; Gubics, David A.

    2010-01-01

    Free-piston Stirling convertors are fundamental to the development of NASA s next generation of radioisotope power system, the Advanced Stirling Radioisotope Generator (ASRG). The ASRG will use General Purpose Heat Source (GPHS) modules as the energy source and Advanced Stirling Convertors (ASCs) to convert heat into electrical energy, and is being developed by Lockheed Martin under contract to the Department of Energy. Achieving flight status mandates that the ASCs satisfy design as well as flight requirements to ensure reliable operation during launch. To meet these launch requirements, GRC performed a series of quasi-static mechanical tests simulating the pressure, thermal, and external loading conditions that will be experienced by an ASC E2 heater head assembly. These mechanical tests were collectively referred to as lateral load tests since a primary external load lateral to the heater head longitudinal axis was applied in combination with the other loading conditions. The heater head was subjected to the operational pressure, axial mounting force, thermal conditions, and axial and lateral launch vehicle acceleration loadings. To permit reliable prediction of the heater head s structural performance, GRC completed Finite Element Analysis (FEA) computer modeling for the stress, strain, and deformation that will result during launch. The heater head lateral load test directly supported evaluation of the analysis and validation of the design to meet launch requirements. This paper provides an overview of each element within the test and presents assessment of the modeling as well as experimental results of this task.

  18. 29 CFR 1917.93 - Head protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... of the following consensus standards: (i) ANSI Z89.1-2003, “American National Standard for Industrial... National Standard for Industrial Head Protection,” which is incorporated by reference in § 1917.3; or (iii...

  19. 29 CFR 1917.93 - Head protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... of the following consensus standards: (i) ANSI Z89.1-2003, “American National Standard for Industrial... National Standard for Industrial Head Protection,” which is incorporated by reference in § 1917.3; or (iii...

  20. Conditions that masquerade as chronic rhinosinusitis: a medical record review.

    PubMed

    Pynnonen, Melissa A; Terrell, Jeffrey E

    2006-07-01

    To identify conditions that are commonly mistaken for chronic rhinosinusitis (CRS). The hypothesis was that many patients referred to a rhinology clinic with a presumptive diagnosis of CRS do not have CRS. Retrospective, observational design study of adult patients referred for evaluation of CRS-like symptoms. The expert opinion of the rhinologist was the diagnostic standard. Tertiary care rhinology clinic. A consecutive sample of 186 patients referred to the University of Michigan Health Systems' Department of Otolaryngology-Head and Neck Surgery between April 1998 and June 2000 for evaluation of CRS-like symptoms. For each patient, a history was obtained and a physical examination was performed, including nasal endoscopy and, when indicated, computed tomographic evaluation of the sinuses. Each patient's diagnosis at referral, CRS, was compared with the final diagnosis made by the rhinologist. The final diagnoses were collected and analyzed using descriptive statistics. Of 186 patients, 112 (60%) had CRS and 74 (40%) did not. The most common diagnoses among the patients who did not have CRS were allergic rhinitis (n = 37), laryngitis associated with reflux (n = 21), head or facial pain (n = 18), and nonallergic rhinitis (n = 23). Many patients had more than 1 diagnosis. Among a tertiary care population, common medical disorders, including rhinitis, laryngitis associated with reflux, and headache disorders, may simulate CRS. Heightened awareness of these conditions may improve diagnostic accuracy in patients with CRS-like symptoms.

  1. Spatial coding of eye movements relative to perceived earth and head orientations during static roll tilt

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Paloski, W. H.; Reschke, M. F.

    1998-01-01

    This purpose of this study was to examine the spatial coding of eye movements during static roll tilt (up to +/-45 degrees) relative to perceived earth and head orientations. Binocular videographic recordings obtained in darkness from eight subjects allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the true earth and head orientations. We found that both variability and curvature of gaze trajectories increased with roll tilt. The trajectories of eye movements made along the perceived earth-horizontal (PEH) were more accurate than movements along the perceived head-horizontal (PHH). The trajectories of both PEH and PHH saccades tended to deviate in the same direction as the head tilt. The deviations in gaze trajectories along the perceived earth-vertical (PEV) and perceived head-vertical (PHV) were both similar to the PHH orientation, except that saccades along the PEV deviated in the opposite direction relative to the head tilt. The magnitude of deviations along the PEV, PHH, and PHV corresponded to perceptual overestimations of roll tilt obtained from verbal reports. Both PEV gaze trajectories and perceptual estimates of tilt orientation were different following clockwise rather than counterclockwise tilt rotation; however, the PEH gaze trajectories were less affected by the direction of tilt rotation. Our results suggest that errors in gaze trajectories along PEV and perceived head orientations increase during roll tilt in a similar way to perceptual errors of tilt orientation. Although PEH and PEV gaze trajectories became nonorthogonal during roll tilt, we conclude that the spatial coding of eye movements during roll tilt is overall more accurate for the perceived earth reference frame than for the perceived head reference frame.

  2. Effect of reference conditions on flow rate, modifier fraction and retention in supercritical fluid chromatography.

    PubMed

    De Pauw, Ruben; Shoykhet Choikhet, Konstantin; Desmet, Gert; Broeckhoven, Ken

    2016-08-12

    When using compressible mobile phases such as fluidic CO2, the density, the volumetric flow rates and volumetric fractions are pressure dependent. The pressure and temperature definition of these volumetric parameters (referred to as the reference conditions) may alter between systems, manufacturers and operating conditions. A supercritical fluid chromatography system was modified to operate in two modes with different definition of the eluent delivery parameters, referred to as fixed and variable mode. For the variable mode, the volumetric parameters are defined with reference to the pump operating pressure and actual pump head temperature. These conditions may vary when, e.g. changing the column length, permeability, flow rate, etc. and are thus variable reference conditions. For the fixed mode, the reference conditions were set at 150bar and 30°C, resulting in a mass flow rate and mass fraction of modifier definition which is independent of the operation conditions. For the variable mode, the mass flow rate of carbon dioxide increases with system pump operating pressure, decreasing the fraction of modifier. Comparing the void times and retention factor shows that the deviation between the two modes is almost independent of modifier percentage, but depends on the operating pressure. Recalculating the set volumetric fraction of modifier to the mass fraction results in the same retention behaviour for both modes. This shows that retention in SFC can be best modelled using the mass fraction of modifier. The fixed mode also simplifies method scaling as it only requires matching average column pressure. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. MetalMapper: A Multi-Sensor TEM System for UXO Detection and Classification

    DTIC Science & Technology

    2011-02-01

    accelerometer  to  measure  pitch  and  roll  angles  and  a  3-­axis   fluxgate   magnetometer  that  provides   reference  heading  to  magnetic...investigations  included  a   magnetometer  transect  survey   and   an   EMI   survey   over   a   larger   area   to   assist   in   selecting   a

  4. 3-D Imagery Cockpit Display Development

    DTIC Science & Technology

    1990-08-01

    and ownship appeared in the lower right corner of the CLF, in the form XXX NM. The third data line showed individual aircraft altitude in the form XX K...data line showed aircraft heading in the form XXX ° . 4.2.5.3 Close-Look Format Options The Close-Look Format option switches are shown in Figure 4.2...vector, it is Need for declutter levels, redundant. Need range readout. Needs basic altitude reference. Low altitude warning system with sexy female

  5. An Assessment of Technical and Production Risks of Candidate Low-Cost Attitude/Heading Reference Systems(AHRS)

    NASA Technical Reports Server (NTRS)

    Yuchnovicz, Daniel; Burgess, Malcolm; Hammers, William

    1999-01-01

    This report provides an assessment of technical and production risks of candidate low-cost attitude/heading reference systems (AHRS) for use in the Advanced General Aviation Transport Experiments (AGATE) airplanes. A low-cost AHRS is a key component of modem "glass cockpit" flight displays for General Aviation (GA) aircraft. The technical capabilities of several candidate low-cost AHRS were examined and described along with the technical issues involved with using all solid-state components for attitude measurement. An economic model was developed which describes the expected profit, rate of return, and volume requirements for the manufacture of low-cost AHRS for GA aircraft in the 2000 to 2020 time frame. The model is the result of interviews with GA airframe manufacturers, avionics manufacturers and historical analysis of avionics of similar complexity. The model shows that a manufacturer will break even after three years of AHRS production, realizing an 18 percent rate of return (23 percent profit) on an investment of $3.5M over the 20 year period. A start-up production estimate showed costs of $6-12M for a new company to build and certify an AHRS from scratch, considered to be a high-risk proposition, versus $0.25-0.75M for an experienced avionics manufacturer to manufacture a design under license, a low-risk proposition.

  6. Vision Screening: A Study of 297 Head Start Children.

    ERIC Educational Resources Information Center

    Morse, A. R.; And Others

    1987-01-01

    Vision assessments were provided to 297 preschoolers in nine Head Start programs in New York State. The protocol used provided a thorough evaluation and required only seven minutes per child. Sixty-three children (21.2%) were referred for further evaluation. Visual deficits detected included decreased acuity, strabismus, astigmatism, and…

  7. Ranging in Human Sonar: Effects of Additional Early Reflections and Exploratory Head Movements

    PubMed Central

    Wallmeier, Ludwig; Wiegrebe, Lutz

    2014-01-01

    Many blind people rely on echoes from self-produced sounds to assess their environment. It has been shown that human subjects can use echolocation for directional localization and orientation in a room, but echo-acoustic distance perception - e.g. to determine one's position in a room - has received little scientific attention, and systematic studies on the influence of additional early reflections and exploratory head movements are lacking. This study investigates echo-acoustic distance discrimination in virtual echo-acoustic space, using the impulse responses of a real corridor. Six blindfolded sighted subjects and a blind echolocation expert had to discriminate between two positions in the virtual corridor, which differed by their distance to the front wall, but not to the lateral walls. To solve this task, participants evaluated echoes that were generated in real time from self-produced vocalizations. Across experimental conditions, we systematically varied the restrictions for head rotations, the subjects' orientation in virtual space and the reference position. Three key results were observed. First, all participants successfully solved the task with discrimination thresholds below 1 m for all reference distances (0.75–4 m). Performance was best for the smallest reference distance of 0.75 m, with thresholds around 20 cm. Second, distance discrimination performance was relatively robust against additional early reflections, compared to other echolocation tasks like directional localization. Third, free head rotations during echolocation can improve distance discrimination performance in complex environmental settings. However, head movements do not necessarily provide a benefit over static echolocation from an optimal single orientation. These results show that accurate distance discrimination through echolocation is possible over a wide range of reference distances and environmental conditions. This is an important functional benefit of human echolocation, which may also play a major role in the calibration of auditory space representations. PMID:25551226

  8. A Transcriptomic Analysis of Cave, Surface, and Hybrid Isopod Crustaceans of the Species Asellus aquaticus

    PubMed Central

    Stahl, Bethany A.; Gross, Joshua B.; Speiser, Daniel I.; Oakley, Todd H.; Patel, Nipam H.; Gould, Douglas B.; Protas, Meredith E.

    2015-01-01

    Cave animals, compared to surface-dwelling relatives, tend to have reduced eyes and pigment, longer appendages, and enhanced mechanosensory structures. Pressing questions include how certain cave-related traits are gained and lost, and if they originate through the same or different genetic programs in independent lineages. An excellent system for exploring these questions is the isopod, Asellus aquaticus. This species includes multiple cave and surface populations that have numerous morphological differences between them. A key feature is that hybrids between cave and surface individuals are viable, which enables genetic crosses and linkage analyses. Here, we advance this system by analyzing single animal transcriptomes of Asellus aquaticus. We use high throughput sequencing of non-normalized cDNA derived from the head of a surface-dwelling male, the head of a cave-dwelling male, the head of a hybrid male (produced by crossing a surface individual with a cave individual), and a pooled sample of surface embryos and hatchlings. Assembling reads from surface and cave head RNA pools yielded an integrated transcriptome comprised of 23,984 contigs. Using this integrated assembly as a reference transcriptome, we aligned reads from surface-, cave- and hybrid- head tissue and pooled surface embryos and hatchlings. Our approach identified 742 SNPs and placed four new candidate genes to an existing linkage map for A. aquaticus. In addition, we examined SNPs for allele-specific expression differences in the hybrid individual. All of these resources will facilitate identification of genes and associated changes responsible for cave adaptation in A. aquaticus and, in concert with analyses of other species, will inform our understanding of the evolutionary processes accompanying adaptation to the subterranean environment. PMID:26462237

  9. An auto-locked diode laser system for precision metrology

    NASA Astrophysics Data System (ADS)

    Beica, H. C.; Carew, A.; Vorozcovs, A.; Dowling, P.; Pouliot, A.; Barron, B.; Kumarakrishnan, A.

    2017-05-01

    We present a unique external cavity diode laser system that can be auto-locked with reference to atomic and molecular spectra. The vacuum-sealed laser head design uses an interchangeable base-plate comprised of a laser diode and optical elements that can be selected for desired wavelength ranges. The feedback light to the laser diode is provided by a narrow-band interference filter, which can be tuned from outside the laser cavity to fineadjust the output wavelength in vacuum. To stabilize the laser frequency, the digital laser controller relies either on a pattern-matching algorithm stored in memory, or on first or third derivative feedback. We have used the laser systems to perform spectroscopic studies in rubidium at 780 nm, and in iodine at 633 nm. The linewidth of the 780-nm laser system was measured to be ˜500 kHz, and we present Allan deviation measurements of the beat note and the lock stability. Furthermore, we show that the laser system can be the basis for a new class of lidar transmitters in which a temperature-stabilized fiber-Bragg grating is used to generate frequency references for on-line points of the transmitter. We show that the fiber-Bragg grating spectra can be calibrated with reference to atomic transitions.

  10. Sensorimotor Adaptation Following Exposure to Ambiguous Inertial Motion Cues

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Clement, G. R.; Harm, D L.; Rupert, A. H.; Guedry, F. E.; Reschke, M. F.

    2005-01-01

    The central nervous system must resolve the ambiguity of inertial motion sensory cues in order to derive accurate spatial orientation awareness. Our general hypothesis is that the central nervous system utilizes both multi-sensory integration and frequency segregation as neural strategies to resolve the ambiguity of tilt and translation stimuli. Movement in an altered gravity environment, such as weightlessness without a stable gravity reference, results in new patterns of sensory cues. For example, the semicircular canals, vision and neck proprioception provide information about head tilt on orbit without the normal otolith head-tilt position that is omnipresent on Earth. Adaptive changes in how inertial cues from the otolith system are integrated with other sensory information lead to perceptual and postural disturbances upon return to Earth s gravity. The primary goals of this ground-based research investigation are to explore physiological mechanisms and operational implications of disorientation and tilt-translation disturbances reported by crewmembers during and following re-entry, and to evaluate a tactile prosthesis as a countermeasure for improving control of whole-body orientation during tilt and translation motion.

  11. Sensorimotor Adaptation Following Exposure to Ambiguous Inertial Motion Cues

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Clement, G. R.; Harm, D. L.; Rupert, A. H.; Guedry, F. E.; Reschke, M. F.

    2005-01-01

    The central nervous system must resolve the ambiguity of inertial motion sensory cues in order to derive accurate spatial orientation awareness. Our general hypothesis is that the central nervous system utilizes both multi-sensory integration and frequency segregation as neural strategies to resolve the ambiguity of tilt and translation stimuli. Movement in an altered gravity environment, such as weightlessness without a stable gravity reference, results in new patterns of sensory cues. For example, the semicircular canals, vision and neck proprioception provide information about head tilt on orbit without the normal otolith head-tilt position that is omnipresent on Earth. Adaptive changes in how inertial cues from the otolith system are integrated with other sensory information lead to perceptual and postural disturbances upon return to Earth's gravity. The primary goals of this ground-based research investigation are to explore physiological mechanisms and operational implications of disorientation and tilt-translation disturbances reported by crewmembers during and following re-entry, and to evaluate a tactile prosthesis as a countermeasure for improving control of whole-body orientation during tilt and translation motion.

  12. The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qian, S.; Jark, W.; Takacs, P.Z.

    1995-03-01

    Metrology requirements for optical components for third-generation synchrotron sources are taxing the state of the art in manufacturing technology. We have investigated a number of error sources in a commercial figure measurement instrument, the Long-Trace-Profiler II, and have demonstrated that, with some simple modifications, we can significantly reduce the effect of error sources and improve the accuracy and reliability of the measurement. By keeping the optical head stationary and moving a penta prism along the translation stage, as in the original pencil-beam interferometer design of von Bieren, the stability of the optical system is greatly improved, and the remaining errormore » signals can be corrected by a simple reference beam subtraction. We illustrate the performance of the modified system by investigating the distortion produced by gravity on a typical synchrotron mirror and demonstrate the repeatability of the instrument despite relaxed tolerances on the translation stage.« less

  13. Dual motor drive vehicle speed synchronization and coordination control strategy

    NASA Astrophysics Data System (ADS)

    Huang, Hao; Tu, Qunzhang; Jiang, Chenming; Ma, Limin; Li, Pei; Zhang, Hongxing

    2018-04-01

    Multi-motor driven systems are more and more widely used in the field of electric engineering vehicles, as a result of the road conditions and the variable load of engineering vehicles, makes multi-motors synchronization coordinated control system as a key point of the development of the electric vehicle drive system. This paper based on electrical machinery transmission speed in the process of engineering vehicles headed for coordinated control problem, summarized control strategies at home and abroad in recent years, made analysis and comparison of the characteristics, finally discussed the trend of development of the multi-motor coordination control, provided a reference for synchronized control system research of electric drive engineering vehicles.

  14. Versatile optical coherence tomography for imaging the human eye

    PubMed Central

    Tao, Aizhu; Shao, Yilei; Zhong, Jianguang; Jiang, Hong; Shen, Meixiao; Wang, Jianhua

    2013-01-01

    We demonstrated the feasibility of a CMOS-based spectral domain OCT (SD-OCT) for versatile ophthalmic applications of imaging the corneal epithelium, limbus, ocular surface, contact lens, crystalline lens, retina, and full eye in vivo. The system was based on a single spectrometer and an alternating reference arm with four mirrors. A galvanometer scanner was used to switch the reference beam among the four mirrors, depending on the imaging application. An axial resolution of 7.7 μm in air, a scan depth of up to 37.7 mm in air, and a scan speed of up to 70,000 A-lines per second were achieved. The approach has the capability to provide high-resolution imaging of the corneal epithelium, contact lens, ocular surface, and tear meniscus. Using two reference mirrors, the zero delay lines were alternatively placed on the front cornea or on the back lens. The entire ocular anterior segment was imaged by registering and overlapping the two images. The full eye through the pupil was measured when the reference arm was switched among the four reference mirrors. After mounting a 60 D lens in the sample arm, this SD-OCT was used to image the retina, including the macula and optical nerve head. This system demonstrates versatility and simplicity for multi-purpose ophthalmic applications. PMID:23847729

  15. An organic transistor-based system for reference-less electrophysiological monitoring of excitable cells

    PubMed Central

    Spanu, A.; Lai, S.; Cosseddu, P.; Tedesco, M.; Martinoia, S.; Bonfiglio, A.

    2015-01-01

    In the last four decades, substantial advances have been done in the understanding of the electrical behavior of excitable cells. From the introduction in the early 70's of the Ion Sensitive Field Effect Transistor (ISFET), a lot of effort has been put in the development of more and more performing transistor-based devices to reliably interface electrogenic cells such as, for example, cardiac myocytes and neurons. However, depending on the type of application, the electronic devices used to this aim face several problems like the intrinsic rigidity of the materials (associated with foreign body rejection reactions), lack of transparency and the presence of a reference electrode. Here, an innovative system based on a novel kind of organic thin film transistor (OTFT), called organic charge modulated FET (OCMFET), is proposed as a flexible, transparent, reference-less transducer of the electrical activity of electrogenic cells. The exploitation of organic electronics in interfacing the living matters will open up new perspectives in the electrophysiological field allowing us to head toward a modern era of flexible, reference-less, and low cost probes with high-spatial and high-temporal resolution for a new generation of in-vitro and in-vivo monitoring platforms. PMID:25744085

  16. Aerial Video Imaging

    NASA Technical Reports Server (NTRS)

    1991-01-01

    When Michael Henry wanted to start an aerial video service, he turned to Johnson Space Center for assistance. Two NASA engineers - one had designed and developed TV systems in Apollo, Skylab, Apollo- Soyuz and Space Shuttle programs - designed a wing-mounted fiberglass camera pod. Camera head and angles are adjustable, and the pod is shaped to reduce vibration. The controls are located so a solo pilot can operate the system. A microprocessor displays latitude, longitude, and bearing, and a GPS receiver provides position data for possible legal references. The service has been successfully utilized by railroads, oil companies, real estate companies, etc.

  17. Zero Launch Mass Three Dimensional Print Head

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Gelino, Nathan J.; Smith, Jonathan D.; Buckles, Brad C.; Lippitt, Thomas; Schuler, Jason M.; Nick, Andrew J.; Nugent, Matt W.; Townsend, Ivan I.

    2018-01-01

    NASA's strategic goal is to put humans on Mars in the 2030's. The NASA Human Spaceflight Architecture Team (HAT) and NASA Mars Design Reference Architecture (DRA) 5.0 has determined that in-situ resource utilization (ISRU) is an essential technology to accomplish this mission. Additive construction technology using in-situ materials from planetary surfaces will reduce launch mass, allow structures to be three dimensionally (3D) printed on demand, and will allow building designs to be transmitted digitally from Earth and printed in space. This will ultimately lead to elimination of reliance on structural materials launched from Earth (zero launch mass of construction consumables). The zero launch mass (ZLM) 3D print head project addressed this need by developing a system that 3D prints using a mixture of in-situ regolith and polymer as feedstock, determining the optimum mixture ratio and regolith particle size distribution, developing software to convert g-code into motion instructions for a FANUC robotic arm, printing test samples, performing materials testing, and printing a reduced scale habitable structure concept. This paper will focus on the ZLM 3D Print Head design, materials selection, software development, and lessons learned from operating the system in the NASA KSC Swamp Works Granular Mechanics & Regolith Operations (GMRO) Laboratory.

  18. Craniofacial morphologic parameters in a Persian population: an anthropometric study.

    PubMed

    Amini, Fariborz; Mashayekhi, Ziba; Rahimi, Hajir; Morad, Golnaz

    2014-09-01

    Limited data are available regarding the reference ranges of facial proportions of the Persian population in Iran. This study aimed to establish the reference range of craniofacial anthropometric measurements in an adult Iranian population. On 100 individuals (men = women), aged 18 to 30 years with normal faces and occlusions, 34 linear and 7 angular measurements as well as 24 indices were calculated. The difference of measurements between men and women were evaluated by paired t-test. The data were compared with the norms of North American whites using 1-sample t-test. The subjects belonged to 5 ethnic groups (57% from Fars, 14% from Kord, 11% from Azari, 10% from Gilaki-Mazani, and 2% from Lor). All head measurements were greater in men except for the head index and the head height. The subjects had leptoprosopic faces. The intercanthal width was almost one third of the biocular width and greater than the eye fissure length. Although the nose width of women was significantly smaller, both sexes had leptorrhine noses. The chin height and lower chin height were greater in men. In comparison with North American whites, considerable differences were found regarding head height and width, biocular width, nose height, face height, mouth width, and upper chin height. In conclusion, the reference range of craniofacial anthropometric measurements established for the Iranian population might be efficiently used for esthetic treatments.

  19. High-performance intraoperative cone-beam CT on a mobile C-arm: an integrated system for guidance of head and neck surgery

    NASA Astrophysics Data System (ADS)

    Siewerdsen, J. H.; Daly, M. J.; Chan, H.; Nithiananthan, S.; Hamming, N.; Brock, K. K.; Irish, J. C.

    2009-02-01

    A system for intraoperative cone-beam CT (CBCT) surgical guidance is under development and translation to trials in head and neck surgery. The system provides 3D image updates on demand with sub-millimeter spatial resolution and soft-tissue visibility at low radiation dose, thus overcoming conventional limitations associated with preoperative imaging alone. A prototype mobile C-arm provides the imaging platform, which has been integrated with several novel subsystems for streamlined implementation in the OR, including: real-time tracking of surgical instruments and endoscopy (with automatic registration of image and world reference frames); fast 3D deformable image registration (a newly developed multi-scale Demons algorithm); 3D planning and definition of target and normal structures; and registration / visualization of intraoperative CBCT with the surgical plan, preoperative images, and endoscopic video. Quantitative evaluation of surgical performance demonstrates a significant advantage in achieving complete tumor excision in challenging sinus and skull base ablation tasks. The ability to visualize the surgical plan in the context of intraoperative image data delineating residual tumor and neighboring critical structures presents a significant advantage to surgical performance and evaluation of the surgical product. The system has been translated to a prospective trial involving 12 patients undergoing head and neck surgery - the first implementation of the research prototype in the clinical setting. The trial demonstrates the value of high-performance intraoperative 3D imaging and provides a valuable basis for human factors analysis and workflow studies that will greatly augment streamlined implementation of such systems in complex OR environments.

  20. Massively parallel diffuse optical tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandusky, John V.; Pitts, Todd A.

    Diffuse optical tomography systems and methods are described herein. In a general embodiment, the diffuse optical tomography system comprises a plurality of sensor heads, the plurality of sensor heads comprising respective optical emitter systems and respective sensor systems. A sensor head in the plurality of sensors heads is caused to act as an illuminator, such that its optical emitter system transmits a transillumination beam towards a portion of a sample. Other sensor heads in the plurality of sensor heads act as observers, detecting portions of the transillumination beam that radiate from the sample in the fields of view of themore » respective sensory systems of the other sensor heads. Thus, sensor heads in the plurality of sensors heads generate sensor data in parallel.« less

  1. Head stabilisation in fast running lizards.

    PubMed

    Goyens, Jana; Aerts, Peter

    2018-04-01

    The cyclic patterns of terrestrial animal locomotion are frequently perturbed in natural environments. The terrain can be complex or inclined, the substrate can move unexpectedly and animals can misjudge situations. Loosing stability due to perturbations increases the probability of capture by predators and decreases the chance of successful prey capture and winning intraspecific battles. When controlled corrective actions are necessary to negotiate perturbations, animals rely on their exteroceptive and proprioceptive senses to monitor the environment and their own body movements. The vestibular system in the inner ear perceives linear and angular accelerations. This information enables gaze stabilisation and the creation of a stable, world-bound reference frame for the integration of the information of other senses. During locomotion, both functions are known to be facilitated by head stabilisation in several animals with an erect posture. Animals with a sprawled body posture, however, undergo very large body undulations while running. Using high speed video recordings, we tested whether they nevertheless stabilise their head during running, and how this is influenced by perturbations. We found that running Acanthodactylus boskianus lizards strongly stabilise their head yaw rotations when running on a flat, straight runway: the head rotation amplitude is only 4.76±0.99°, while the adjacent trunk part rotates over 27.0±3.8°. Lateral head translations are not stabilised (average amplitude of 7.4±2.0mm). When the lizards are experimentally perturbed by a large and unexpected lateral substrate movement, lateral translations of both the head and the body decrease (on average by 1.52±0.81mm). At the same time, the rotations of the head and trunk also decrease (on average by 1.62°±7.21°). These results show that head stabilisation intensifies because of the perturbation, which emphasises the importance of vestibular perception and balance in these fast and manoeuvrable animals. Copyright © 2017 Elsevier GmbH. All rights reserved.

  2. [Epidemiological and Demographic Characteristics of Patients with Head and Neck Tumours in the Northern Portugal: Impact on Survival].

    PubMed

    Estêvão, Roberto; Santos, Tiago; Ferreira, Ana; Machado, Anabela; Fernandes, João; Monteiro, Eurico

    2016-10-01

    In Portugal there are still no epidemiological and demographic studies conducted in patients with of the head and neck tumors. The objectives of this analysis are to describe the epidemiological and demographics of patients with malignant tumors of the head and neck referred to an Ear, Nose and Throat department of an oncology center in the North of Portugal and also assess the impact of these characteristics on survival. Retrospective study of patients referred between January 2011 and December 2013 to the Ear, Nose and Throat Department of an oncology center (Instituto Português de Oncologia do Porto),. Five hundred sixty six patients were included. The analyzed variables were the anatomical location of the tumor, staging, gender and age of patients, the district of origin, the alcohol and tobacco consumption, educational level, occupation, marital status and family structure. The 566 patients studied (498 men and 68 women) presented a mean age of 58.1 ± 12.2 years. The majority (80.5%) were referenced in advanced stage of disease (III and IV). Seventy eight per cent of patients had moderate or excessive alcohol consumption and 69% were smokers. The vast majority of patients (82.3%) had only basic education. Patients with tumors of the hypopharynx and excessive drinking habits were referenced in more advanced stages and had a poorer survival (p < 0.001). Married patients were referred at earlier stages (p = 0.020) and patients without family support had poorer survival (p = 0.030). Epidemiological data are in agreement with the international literature. The high rate of patients referred with advanced stage of disease can be attributed to the patient´s delay in seeking medical care or by factors inherent to the referral system. Surveillance and family support play a key role in early referral and survival of these patients. This study features a population profile that can benefit from a higher degree of surveillance, awareness campaigns and/ or screenings. Some of the variables can significantly influence the tumor stage and survival.

  3. Development of multichannel MEG system at IGCAR

    NASA Astrophysics Data System (ADS)

    Mariyappa, N.; Parasakthi, C.; Gireesan, K.; Sengottuvel, S.; Patel, Rajesh; Janawadkar, M. P.; Radhakrishnan, T. S.; Sundar, C. S.

    2013-02-01

    We describe some of the challenging aspects in the indigenous development of the whole head multichannel magnetoencephalography (MEG) system at IGCAR, Kalpakkam. These are: i) fabrication and testing of a helmet shaped sensor array holder of a polymeric material experimentally tested to be compatible with liquid helium temperatures, ii) the design and fabrication of the PCB adapter modules, keeping in mind the inter-track cross talk considerations between the electrical leads used to provide connections from SQUID at liquid helium temperature (4.2K) to the electronics at room temperature (300K) and iii) use of high resistance manganin wires for the 86 channels (86×8 leads) essential to reduce the total heat leak which, however, inevitably causes an attenuation of the SQUID output signal due to voltage drop in the leads. We have presently populated 22 of the 86 channels, which include 6 reference channels to reject the common mode noise. The whole head MEG system to cover all the lobes of the brain will be progressively assembled when other three PCB adapter modules, presently under fabrication, become available. The MEG system will be used for a variety of basic and clinical studies including localization of epileptic foci during pre-surgical mapping in collaboration with neurologists.

  4. Scope Notes for LISA Subject Headings.

    ERIC Educational Resources Information Center

    Browne, Glenda

    1992-01-01

    Reports on a study that examined scope notes added to subject headings in the Library and Information Science Abstracts (LISA) Online User Manual. Types of messages conveyed by scope notes and word patterns within the notes are identified, and comparisons between the 1982 and 1987 editions of the manual are made. (16 references) (MES)

  5. Collisional phase shifts of ring dark solitons in inhomogeneous Bose Einstein condensates

    NASA Astrophysics Data System (ADS)

    Peng, Ping; Li, Guan-Qiang; Xue, Ju-Kui

    2007-06-01

    The head-on collisions of two ring dark solitons in inhomogeneous Bose Einstein condensates (BECs) with thin disk-shaped potential are studied by the extended Poincaré Lighthill Kuo (PLK) perturbation method. The result shows that the system admits a solution with two concentric ring solitons, one moving inwards and the other moving outwards, which in small-amplitude limit, are described by two modified cylindrical KdV equations in the respective reference frames. In particular, the analytical phase shifts induced by the head-on collisions between two ring dark solitary waves are derived, and the result shows that the phase shifts change with the radial coordinate r according to the (1+σr)r law (where σ˜ωr2/ωz2), which are quite different with the homogeneous case.

  6. A Robust Nonlinear Observer for Real-Time Attitude Estimation Using Low-Cost MEMS Inertial Sensors

    PubMed Central

    Guerrero-Castellanos, José Fermi; Madrigal-Sastre, Heberto; Durand, Sylvain; Torres, Lizeth; Muñoz-Hernández, German Ardul

    2013-01-01

    This paper deals with the attitude estimation of a rigid body equipped with angular velocity sensors and reference vector sensors. A quaternion-based nonlinear observer is proposed in order to fuse all information sources and to obtain an accurate estimation of the attitude. It is shown that the observer error dynamics can be separated into two passive subsystems connected in “feedback”. Then, this property is used to show that the error dynamics is input-to-state stable when the measurement disturbance is seen as an input and the error as the state. These results allow one to affirm that the observer is “robustly stable”. The proposed observer is evaluated in real-time with the design and implementation of an Attitude and Heading Reference System (AHRS) based on low-cost MEMS (Micro-Electro-Mechanical Systems) Inertial Measure Unit (IMU) and magnetic sensors and a 16-bit microcontroller. The resulting estimates are compared with a high precision motion system to demonstrate its performance. PMID:24201316

  7. An EUV Study of the Eclipsing M-Dwarf Binary System YY GEM

    NASA Technical Reports Server (NTRS)

    Drake, Jeremy

    2000-01-01

    EUVE, SW, MW and LW spectra have been reduced and line fluxes measured. The Deep Survey data has been analyzed and light curves have been derived. The spectra around the HE II 304 region show some evidence of emission from the bright A companion star, Castor. Preliminary results for the metallicity of the corona of YY Gem were derived from the EUVE spectra and photometry and were presented at the AAS HEAD meeting; results are being finalized for publication in a referred journal.

  8. When Freud headed for the East: aspects of a Chinese translation of his works.

    PubMed

    Plaenkers, Tomas

    2013-10-01

    Working on the basis of a resumé of the Chinese translations to date of individual works by Sigmund Freud and critiques of these as secondary translations from the English, the particular difficulties of translating into a non-Indo-European language with an isolating and analytical writing system are presented. By way of introduction, reference is made to English and French-language contributions to the issues of translation. Copyright © 2013 Institute of Psychoanalysis.

  9. Alopecia due to an allergic reaction to metal head-pins used in a neurosurgical operation.

    PubMed

    Ono, Hajime; Takasuna, Hiroshi; Tanaka, Yuichiro

    2016-01-01

    Allergic reactions to the metal head-pins of a head fixation holder are rare. A 45-year-old woman was referred to our hospital for the treatment of unruptured cerebral aneurysms. She underwent successful surgical treatment using four head-pins of the Sugita frame. At her first outpatient visit 3 weeks after discharge, redness, sores, and focal hair loss were noted at all four areas where the pinning had been performed. The pin fixation was considered to be responsible for the alopecia because the condition of the scalp lesions was even in all four parts. Six months later, the scalp regained hair. The head-pins were made of stainless steel, containing iron, nickel, chromium, and other components. A previous history of contact dermatitis to metal jewellery was later proven. The history of metal allergy should have been carefully elicited because head fixation with head-pins is essential for neurosurgical procedures.

  10. Triple bypass for advanced pancreatic head cancer associated with biliary stricture, duodenal stenosis, and recurrent obstructive pancreatitis.

    PubMed

    Kudo, Yuzan; Sato, Norihiro; Tamura, Toshihisa; Hirata, Keiji

    2016-12-01

    Bypass surgery for cancer of the pancreatic head is usually done to palliate the obstructive symptoms in the biliary and/or digestive system. However, it is uncommon for patients to require pancreatic duct drainage for recurrent obstructive pancreatitis. In this article, we report a surgical technique of triple bypass consisting of Roux-en-Y hepaticojejunostomy, gastrojejunostomy, and pancreaticojejunostomy for advanced pancreatic cancer. A 76-year-old male patient with locally advanced and metastatic pancreatic head cancer was referred to our department for biliary stricture, duodenal stenosis, and recurrent obstructive pancreatitis associated with persistent pancreatic pseudocyst. In an attempt to resolve all these problems simultaneously, a triple bypass was performed. The patient survived and continued to receive chemotherapy for almost 1 year after surgery without any serious complications. Thus, triple bypass is a useful surgical technique that could relief symptoms and offer better quality of life to patients with advanced pancreatic cancer presenting with biliary stricture, duodenal stenosis, and severe obstructive pancreatitis difficult to treat by medication or endoscopic procedures.

  11. Empirical Study on Designing of Gaze Tracking Camera Based on the Information of User's Head Movement.

    PubMed

    Pan, Weiyuan; Jung, Dongwook; Yoon, Hyo Sik; Lee, Dong Eun; Naqvi, Rizwan Ali; Lee, Kwan Woo; Park, Kang Ryoung

    2016-08-31

    Gaze tracking is the technology that identifies a region in space that a user is looking at. Most previous non-wearable gaze tracking systems use a near-infrared (NIR) light camera with an NIR illuminator. Based on the kind of camera lens used, the viewing angle and depth-of-field (DOF) of a gaze tracking camera can be different, which affects the performance of the gaze tracking system. Nevertheless, to our best knowledge, most previous researches implemented gaze tracking cameras without ground truth information for determining the optimal viewing angle and DOF of the camera lens. Eye-tracker manufacturers might also use ground truth information, but they do not provide this in public. Therefore, researchers and developers of gaze tracking systems cannot refer to such information for implementing gaze tracking system. We address this problem providing an empirical study in which we design an optimal gaze tracking camera based on experimental measurements of the amount and velocity of user's head movements. Based on our results and analyses, researchers and developers might be able to more easily implement an optimal gaze tracking system. Experimental results show that our gaze tracking system shows high performance in terms of accuracy, user convenience and interest.

  12. Empirical Study on Designing of Gaze Tracking Camera Based on the Information of User’s Head Movement

    PubMed Central

    Pan, Weiyuan; Jung, Dongwook; Yoon, Hyo Sik; Lee, Dong Eun; Naqvi, Rizwan Ali; Lee, Kwan Woo; Park, Kang Ryoung

    2016-01-01

    Gaze tracking is the technology that identifies a region in space that a user is looking at. Most previous non-wearable gaze tracking systems use a near-infrared (NIR) light camera with an NIR illuminator. Based on the kind of camera lens used, the viewing angle and depth-of-field (DOF) of a gaze tracking camera can be different, which affects the performance of the gaze tracking system. Nevertheless, to our best knowledge, most previous researches implemented gaze tracking cameras without ground truth information for determining the optimal viewing angle and DOF of the camera lens. Eye-tracker manufacturers might also use ground truth information, but they do not provide this in public. Therefore, researchers and developers of gaze tracking systems cannot refer to such information for implementing gaze tracking system. We address this problem providing an empirical study in which we design an optimal gaze tracking camera based on experimental measurements of the amount and velocity of user’s head movements. Based on our results and analyses, researchers and developers might be able to more easily implement an optimal gaze tracking system. Experimental results show that our gaze tracking system shows high performance in terms of accuracy, user convenience and interest. PMID:27589768

  13. Ultrasound melted polymer sleeve for improved screw anchorage in trabecular bone--A novel screw augmentation technique.

    PubMed

    Schmoelz, W; Mayr, R; Schlottig, F; Ivanovic, N; Hörmann, R; Goldhahn, J

    2016-03-01

    Screw anchorage in osteoporotic bone is still limited and makes treatment of osteoporotic fractures challenging for surgeons. Conventional screws fail in poor bone quality due to loosening at the screw-bone interface. A new technology should help to improve this interface. In a novel constant amelioration process technique, a polymer sleeve is melted by ultrasound in the predrilled screw hole prior to screw insertion. The purpose of this study was to investigate in vitro the effect of the constant amelioration process platform technology on primary screw anchorage. Fresh frozen femoral heads (n=6) and vertebrae (n=6) were used to measure the maximum screw insertion torque of reference and constant amelioration process augmented screws. Specimens were cut in cranio-caudal direction, and the screws (reference and constant amelioration process) were implanted in predrilled holes in the trabecular structure on both sides of the cross section. This allowed the pairwise comparison of insertion torque for constant amelioration process and reference screws (femoral heads n=18, vertebrae n=12). Prior to screw insertion, a micro-CT scan was made to ensure comparable bone quality at the screw placement location. The mean insertion torque for the constant amelioration process augmented screws in both, the femoral heads (44.2 Ncm, SD 14.7) and the vertebral bodies (13.5 Ncm, SD 6.3) was significantly higher than for the reference screws of the femoral heads (31.7 Ncm, SD 9.6, p<0.001) and the vertebral bodies (7.1 Ncm, SD 4.5, p<0.001). The interconnection of the melted polymer sleeve with the surrounding trabecular bone in the constant amelioration process technique resulted in a higher screw insertion torque and can improve screw anchorage in osteoporotic trabecular bone. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Down Syndrome: Gestational Age-Related Neonatal Anthropometrics for Germany.

    PubMed

    Hoffmann, Paul F; Jung, Anna-Maria; Stierkorb, Eva; Monz, Dominik; Gortner, Ludwig; Rohrer, Tilman R

    2016-01-01

    Neonates with Down syndrome (DS) weigh less, are smaller and have increased first-year mortality, especially if born small for gestational age (GA). DS-specific GA-related neonatal anthropometrics for Germany are lacking. To construct reference tables and centile curves for birth weight (g), crown-heel length (cm) and head circumference (cm) by sex and GA for German DS neonates. Retrospective anthropometric data from live-born singleton DS neonates born in Germany from January 1966 to June 2010 were collected using standardized questionnaires and patient records. Reference tables were created based on means and standard deviations. The 3rd, 10th, 25th, 50th, 75th, 90th and 97th centile curves were constructed and smoothed using running medians and Cole's LMS method. Anthropometric measurements were obtained for 1,304 DS neonates [males/females: 713/591 (54.7%/45.3%)]. Reference tables and centile charts were constructed from 3,542 (males/females: 1,932/1,610) observations for GA 32-41 weeks. Compared with general-population newborns, prematurity was increased (21.1 vs. 6.3%) at GA 32-36 weeks. Term-born (GA 40 weeks) male and female DS neonates were 352.5 and 223.5 g lighter and 1.5 and 1.4 cm smaller than general-population neonates, and head circumference was also 1.4 and 1.5 cm smaller, respectively. This is the first study to report GA-related, sex-specific reference tables and centile charts of birth weight, length and head circumference for DS neonates born in Germany. Compared with the general German population, DS newborns are more frequently born prematurely, weigh less, are smaller and have a smaller head circumference at birth. © 2016 S. Karger AG, Basel.

  15. Functional neuroanatomy in the pre-Hippocratic era: observations from the Iliad of Homer.

    PubMed

    Sahlas, D J

    2001-06-01

    To describe observations of neurological significance made in the Iliad of Homer and to interpret these relative to pre-Hippocratic concepts of health and disease in Ancient Greece. English translations of the Iliad were analyzed for references of neurological significance, and the Homeric Greek was subsequently reviewed for accuracy. Findings are discussed in the context of ancient Greek ideas regarding anatomy and physiology, early descriptions and conceptualizations of the nervous system, ancient Greek theories concerning illness and disease, and the practice of medicine in the pre-Hippocratic era. Descriptions of injuries sustained by soldiers fighting in the Trojan War represent some of the earliest case histories of neurotrauma. Passages in the Iliad describe immediate death after penetrating head trauma with injury to the brain or the brainstem, make reference to clinical signs of brain injury, and mention neurological signs and symptoms after damage to the spinal cord, brachial plexus, and peripheral nerves. The Iliad of Homer contains many descriptions of traumatic injury to the nervous system and provides us with 3,000-year-old references to some of the basic principles of functional neuroanatomy.

  16. Minimizing Head Acceleration in Soccer: A Review of the Literature.

    PubMed

    Caccese, Jaclyn B; Kaminski, Thomas W

    2016-11-01

    Physicians and healthcare professionals are often asked for recommendations on how to keep athletes safe during contact sports such as soccer. With an increase in concussion awareness and concern about repetitive subconcussion, many parents and athletes are interested in mitigating head acceleration in soccer, so we conducted a literature review on factors that affect head acceleration in soccer. We searched electronic databases and reference lists to find studies using the keywords 'soccer' OR 'football' AND 'head acceleration'. Because of a lack of current research in soccer heading biomechanics, this review was limited to 18 original research studies. Low head-neck segment mass predisposes athletes to high head acceleration, but head-neck-torso alignment during heading and follow-through after contact can be used to decrease head acceleration. Additionally, improvements in symmetric neck flexor and extensor strength and neuromuscular neck stiffness can decrease head acceleration. Head-to-head impacts and unanticipated ball contacts result in the highest head acceleration. Ball contacts at high velocity may also be dangerous. The risk of concussive impacts may be lessened through the use of headgear, but headgear may also cause athletes to play more recklessly because they feel a sense of increased security. Young, but physically capable, athletes should be taught proper heading technique in a controlled setting, using a carefully planned progression of the skill.

  17. Development of a New Low-Cost Indoor Mapping System - System Design, System Calibration and First Results

    NASA Astrophysics Data System (ADS)

    Kersten, T. P.; Stallmann, D.; Tschirschwitz, F.

    2016-06-01

    For mapping of building interiors various 2D and 3D indoor surveying systems are available today. These systems essentially differ from each other by price and accuracy as well as by the effort required for fieldwork and post-processing. The Laboratory for Photogrammetry & Laser Scanning of HafenCity University (HCU) Hamburg has developed, as part of an industrial project, a lowcost indoor mapping system, which enables systematic inventory mapping of interior facilities with low staffing requirements and reduced, measurable expenditure of time and effort. The modelling and evaluation of the recorded data take place later in the office. The indoor mapping system of HCU Hamburg consists of the following components: laser range finder, panorama head (pan-tilt-unit), single-board computer (Raspberry Pi) with digital camera and battery power supply. The camera is pre-calibrated in a photogrammetric test field under laboratory conditions. However, remaining systematic image errors are corrected simultaneously within the generation of the panorama image. Due to cost reasons the camera and laser range finder are not coaxially arranged on the panorama head. Therefore, eccentricity and alignment of the laser range finder against the camera must be determined in a system calibration. For the verification of the system accuracy and the system calibration, the laser points were determined from measurements with total stations. The differences to the reference were 4-5mm for individual coordinates.

  18. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  19. A qualitative systematic review of head-to-head randomized controlled trials of oral analgesics in neuropathic pain

    PubMed Central

    Watson, C Peter N; Gilron, Ian; Sawynok, Jana

    2010-01-01

    BACKGROUND: Neuropathic pain (NP) encompasses many difficult-to-treat disorders. There are few head-to-head, comparative, randomized controlled trials (RCTs) of drugs for NP in different analgesic categories, or of different drugs within a category, despite many placebo-controlled RCTs for individual agents. Well-designed head-to-head comparative trials are an effective way to determine the relative efficacy and safety of a new drug. OBJECTIVE: To perform a systematic review of head-to-head RCTs of oral analgesics in NP. METHODS: A systematic review of RCTs involving NP patients was performed, of which head-to-head comparative trials were selected. Reference lists from published systematic reviews were searched. These studies were rated according to the Jadad scale for quality. RESULTS AND CONCLUSIONS: Twenty-seven such trials were identified. Seventeen were comparisons of different analgesics, and 10 were of different drugs within an analgesic class. Important information was obtained about the relative efficacy and safety of drugs in different categories and within a category. Some significant differences between active treatments were reported. Trial inadequacies were identified. More and improved head-to-head RCTs are needed to inform clinical choices. PMID:20577657

  20. Selected Reference Books of 1971-72

    ERIC Educational Resources Information Center

    Sheehy, Eugene P.

    1973-01-01

    The purpose of this annotated list is to present a selection of recent scholarly and foreign works of interest to reference workers in university libraries. The citations are listed under the following headings: guide, bibliography, encyclopedias, dictionaries, newspapers, dissertations, biography, genealogy, literature, education, sociology,…

  1. Standardised anatomical alignment of the head in a clinical photography studio. A comparison between the Frankfort Horizontal and the natural head position.

    PubMed

    Capon, Thomas

    The Frankfort Horizontal (FH) is used by clinical photographers as a reference plane to help maintain Standardised Representational Photography (SRP) when photographing a patients head. A comparative method of alignment is the Natural Head Position (NHP). For this study a survey was created that asked consultants and clinical photographers which method of alignment they considered to be the most effective. The survey found that 77% of respondents thought the FH was the most effective method of alignment. This high figure is due to some confirmation bias as the FH is the industry standard.

  2. Fiber optic gas detection system for health monitoring of oil-filled transformer

    NASA Astrophysics Data System (ADS)

    Ho, H. L.; Ju, J.; Jin, W.

    2009-10-01

    This paper reports the development of a fiber-optic gas detection system capable of detecting three types of dissolved fault gases in oil-filled power transformers or equipment. The system is based on absorption spectroscopy and the target gases include acetylene (C2H2), methane (CH4) and ethylene (C2H4). Low-cost multi-pass sensor heads using fiber coupled micro-optic cells are employed for which the interaction length is up to 4m. Also, reference gas cells made of photonic bandgap (PBG) fiber are implemented. The minimum detectable gas concentrations for methane, acetylene and ethylene are 5ppm, 2ppm and 50ppm respectively.

  3. [Mechanics and effects of European reference pricing for vaccines in Germany according to §130a Abs. 2 SGB V: an analysis using the example of influenza vaccines].

    PubMed

    Barth, J; Hammerschmidt, T; Vollmar, J; Bierbaum, M; Schöffski, O

    2014-04-01

    On 01 January 2011 the bill for the reorganisation of the pharmaceutical market became effective. Since that time there is a European reference pricing (ERP) system for vaccines in order to bring down the German vaccine prices to an assumed lower European level. This study describes the implementation, functioning and effect of this new system. For influenza vaccines the impact of ERP on the price level and spread of prices is analysed. The description of the mechanism is based on the law and corresponding regulations of the head association of sickness funds (GKV-SV). The analysis of vaccine prices is based on the data of the i:data report (status of 01 September 2011) of ifap Service Institute. The European reference price is calculated as the average price of the manufacturer-selling-prices of the corresponding vaccine in the 4 countries of the European Union whose gross national income comes closest to the German one and in which the vaccine is distributed. The relied prices are weighted by sales and purchasing power parities of the respective countries. This analysis suggests that in particular the practical implementation of the reference price system should be further improved and specified. The calculation of the reference prices should ensure price comparability. In addition, significant problems remain in the deduction of discounts, because no distinction is made in the documentation of vaccinating doctors, whether vaccination was performed as a compulsory or statutory benefit. The comparison of the manufacturer-selling-prices of individual influenza vaccines with the corresponding reference prices shows an enlargement of the existing price differences, which have evolved in a competitive environment, after the implementation of the reference pricing -system. There is still a need for improvement in implementing the reference pricing system. In the most competitive vaccine market of influenza vaccines, the ERP-system lowers the prices, but seems to distort the market prices. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Research publications of the Cascade Head Experimental Forest and Scenic Research Area, Oregon Coast Range, 1934 to 1990.

    Treesearch

    Sarah E. Greene; Tawny Blinn

    1991-01-01

    A list of publications resulting from research at the Cascade Head Experimental Forest and Scenic Research Area, Siuslaw National Forest, Oregon, from 1934 to 1990 is presented. Over 200 publications are listed, including papers, theses, and reports. An index is provided that cross-references the listings under appropriate keywords.

  5. Evaluation of the stability of reference genes in bone mesenchymal stem cells from patients with avascular necrosis of the femoral head.

    PubMed

    Wang, X N; Yang, Q W; Du, Z W; Yu, T; Qin, Y G; Song, Y; Xu, M; Wang, J C

    2016-05-25

    This study aimed to evaluate 12 genes (18S, GAPDH, B2M, ACTB, ALAS1, GUSB, HPRT1, PBGD, PPIA, PUM1, RPL29, and TBP) for their reliability and stability as reference sequences for real-time quantitative PCR (RT-qPCR) in bone marrow-derived mesenchymal stem cells (BMSCs) isolated from patients with avascular necrosis of the femoral head (ANFH). BMSCs were isolated from 20 ANFH patients divided into four groups according to etiology, and four donors with femoral neck fractures. Total RNA was isolated from BMSCs and reverse transcribed into complementary DNA, which served as a template for RT-qPCR. Three commonly used programs were then used to analyze the results. Reference gene expression varied within each group, between specific groups, and among all five groups. Based on comparisons of all five groups, two of the programs used suggested that HPRT1 was the most stable reference gene, while 18S and ACTB were the most variable. Among the 12 candidate reference genes, HPRT1 exhibited the greatest reliability, followed by PPIA. Thus, these sequences could be used as references for the normalization of RT-qPCR results.

  6. Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs.

    PubMed

    Chakrabarty, Lipi; Joshi, Gopal Datt; Chakravarty, Arunava; Raman, Ganesh V; Krishnadas, S R; Sivaswamy, Jayanthi

    2016-07-01

    To describe and evaluate the performance of an automated CAD system for detection of glaucoma from color fundus photographs. Color fundus photographs of 2252 eyes from 1126 subjects were collected from 2 centers: Aravind Eye Hospital, Madurai and Coimbatore, India. The images of 1926 eyes (963 subjects) were used to train an automated image analysis-based system, which was developed to provide a decision on a given fundus image. A total of 163 subjects were clinically examined by 2 ophthalmologists independently and their diagnostic decisions were recorded. The consensus decision was defined to be the clinical reference (gold standard). Fundus images of eyes with disagreement in diagnosis were excluded from the study. The fundus images of the remaining 314 eyes (157 subjects) were presented to 4 graders and their diagnostic decisions on the same were collected. The performance of the system was evaluated on the 314 images, using the reference standard. The sensitivity and specificity of the system and 4 independent graders were determined against the clinical reference standard. The system achieved an area under receiver operating characteristic curve of 0.792 with a sensitivity of 0.716 and specificity of 0.717 at a selected threshold for the detection of glaucoma. The agreement with the clinical reference standard as determined by Cohen κ is 0.45 for the proposed system. This is comparable to that of the image-based decisions of 4 ophthalmologists. An automated system was presented for glaucoma detection from color fundus photographs. The overall evaluation results indicated that the presented system was comparable in performance to glaucoma classification by a manual grader solely based on fundus image examination.

  7. Shakespeare: A Student's Guide to Basic Reference Sources.

    ERIC Educational Resources Information Center

    Claener, Anne, Comp.

    Basic and standard reference materials dealing with William Shakespeare are listed in this bibliography. Annotated entries are grouped under the following headings: concordances, dictionaries, encyclopedias and handbooks, and bibliographies. The section on bibliographies is further divided into lists of editions of Shakespeare's work, general…

  8. Portable real-time color night vision

    NASA Astrophysics Data System (ADS)

    Toet, Alexander; Hogervorst, Maarten A.

    2008-03-01

    We developed a simple and fast lookup-table based method to derive and apply natural daylight colors to multi-band night-time images. The method deploys an optimal color transformation derived from a set of samples taken from a daytime color reference image. The colors in the resulting colorized multiband night-time images closely resemble the colors in the daytime color reference image. Also, object colors remain invariant under panning operations and are independent of the scene content. Here we describe the implementation of this method in two prototype portable dual band realtime night vision systems. One system provides co-aligned visual and near-infrared bands of two image intensifiers, the other provides co-aligned images from a digital image intensifier and an uncooled longwave infrared microbolometer. The co-aligned images from both systems are further processed by a notebook computer. The color mapping is implemented as a realtime lookup table transform. The resulting colorised video streams can be displayed in realtime on head mounted displays and stored on the hard disk of the notebook computer. Preliminary field trials demonstrate the potential of these systems for applications like surveillance, navigation and target detection.

  9. Multisensory guidance of orienting behavior.

    PubMed

    Maier, Joost X; Groh, Jennifer M

    2009-12-01

    We use both vision and audition when localizing objects and events in our environment. However, these sensory systems receive spatial information in different coordinate systems: sounds are localized using inter-aural and spectral cues, yielding a head-centered representation of space, whereas the visual system uses an eye-centered representation of space, based on the site of activation on the retina. In addition, the visual system employs a place-coded, retinotopic map of space, whereas the auditory system's representational format is characterized by broad spatial tuning and a lack of topographical organization. A common view is that the brain needs to reconcile these differences in order to control behavior, such as orienting gaze to the location of a sound source. To accomplish this, it seems that either auditory spatial information must be transformed from a head-centered rate code to an eye-centered map to match the frame of reference used by the visual system, or vice versa. Here, we review a number of studies that have focused on the neural basis underlying such transformations in the primate auditory system. Although, these studies have found some evidence for such transformations, many differences in the way the auditory and visual system encode space exist throughout the auditory pathway. We will review these differences at the neural level, and will discuss them in relation to differences in the way auditory and visual information is used in guiding orienting movements.

  10. Influence of the implanted pulse generator as reference electrode in finite element model of monopolar deep brain stimulation.

    PubMed

    Walckiers, Grégoire; Fuchs, Benjamin; Thiran, Jean-Philippe; Mosig, Juan R; Pollo, Claudio

    2010-01-30

    Electrical deep brain stimulation (DBS) is an efficient method to treat movement disorders. Many models of DBS, based mostly on finite elements, have recently been proposed to better understand the interaction between the electrical stimulation and the brain tissues. In monopolar DBS, clinically widely used, the implanted pulse generator (IPG) is used as reference electrode (RE). In this paper, the influence of the RE model of monopolar DBS is investigated. For that purpose, a finite element model of the full electric loop including the head, the neck and the superior chest is used. Head, neck and superior chest are made of simple structures such as parallelepipeds and cylinders. The tissues surrounding the electrode are accurately modelled from data provided by the diffusion tensor magnetic resonance imaging (DT-MRI). Three different configurations of RE are compared with a commonly used model of reduced size. The electrical impedance seen by the DBS system and the potential distribution are computed for each model. Moreover, axons are modelled to compute the area of tissue activated by stimulation. Results show that these indicators are influenced by the surface and position of the RE. The use of a RE model corresponding to the implanted device rather than the usually simplified model leads to an increase of the system impedance (+48%) and a reduction of the area of activated tissue (-15%). (c) 2009 Elsevier B.V. All rights reserved.

  11. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    NASA Astrophysics Data System (ADS)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  12. Collections Care: A Basic Reference Shelflist.

    ERIC Educational Resources Information Center

    de Torres, Amparo R., Ed.

    This is an extensive bibliography of reference sources--i.e., books and articles--that relate to the care and conservation of library, archival, and museum collections. Bibliographies are presented under the following headings: (1) General Information; (2) Basic Collections Care; (3) Architectural Conservation; (4) Collections Management: Law,…

  13. EVALUATING EXTREMELY LOW FREQUENCY MAGNETIC FIELDS IN THE REAR SEATS OF THE ELECTRIC VEHICLES.

    PubMed

    Lin, Jun; Lu, Meng; Wu, Tong; Yang, Lei; Wu, Tongning

    2018-03-23

    In the electric vehicles (EVs), children can sit on a safety seat installed in the rear seats. Owing to their smaller physical dimensions, their heads, generally, are closer to the underfloor electrical systems where the magnetic field (MF) exposure is the greatest. In this study, the magnetic flux density (B) was measured in the rear seats of 10 different EVs, for different driving sessions. We used the measurement results from different heights corresponding to the locations of the heads of an adult and an infant to calculate the induced electric field (E-field) strength using anatomical human models. The results revealed that measured B fields in the rear seats were far below the reference levels by the International Commission on Non-Ionizing Radiation Protection. Although small children may be exposed to higher MF strength, induced E-field strengths were much lower than that of adults due to their particular physical dimensions.

  14. Differential GPS for air transport: Status

    NASA Technical Reports Server (NTRS)

    Hueschen, Richard M.

    1993-01-01

    The presentation presents background on what the Global Navigation Satellite System (GNSS) is, desired target dates for initial GNSS capabilities for aircraft operations, and a description of differential GPS (Global Positioning System). The presentation also presents an overview of joint flight tests conducted by LaRC and Honeywell on an integrated differential GPS/inertial reference unit (IRU) navigation system. The overview describes the system tested and the results of the flight tests. The last item presented is an overview of a current grant with Ohio University from LaRC which has the goal of developing a precision DGPS navigation system based on interferometry techniques. The fundamentals of GPS interferometry are presented and its application to determine attitude and heading and precision positioning are shown. The presentation concludes with the current status of the grant.

  15. A cephalometric study to establish the relationship of the occlusal plane to the three different ala-tragal lines and the Frankfort horizontal plane in different head forms.

    PubMed

    Subhas, S; Rupesh, P L; Devanna, R; Kumar, D R V; Paliwal, A; Solanki, P

    2017-04-01

    The aim of the study is to compare the relationship of the occlusal plane to 3 different ala-tragal lines, namely the superior, middle and inferior lines, in individuals having different head forms and its relation to the Frankfort horizontal plane. A total of 75 lateral cephalometric radiographs of subjects with natural dentition, having full complement of teeth, between the age group of 18-25 were screened and selected. Lateral cephalogram were made for each subjects in an open mouth position. Prior to making the lateral cephalogram, radiopaque markers were placed on the superior, middle and inferior tragus points and on the inferior border of the ala of the nose. Cephalometric tracing was done over each cephalogram. In mesiocephalic head form the middle ala-tragal line was most parallel to the occlusal plane having a mean angle of (1.96°). In dolichocephalic headform, the superior ala-tragal line was most parallel to the occlusal plane having a mean angle of (0.48°). In brachycephalic head form, the middle ala-tragal line was most parallel to the occlusal plane having a mean angle of (2.08°). The mean angulations of occlusal plane to FH plane is 11.04°, 10.16° and 10.60° in mesiocephalic, dolichocephalic and brachycephalic head forms, respectively. The study concludes that the middle ala-tragal line can be used as a reference for the mesiocephalic head form and the superior ala-tragal line for the dolichocephalic and brachycephalic head form as a reference to establish the occlusal plane. Copyright © 2016. Published by Elsevier Masson SAS.

  16. Abusive head trauma and accidental head injury: a 20-year comparative study of referrals to a hospital child protection team

    PubMed Central

    John, Simon; Vincent, Andrea L; Reed, Peter

    2015-01-01

    Aim To describe children referred for suspected abusive head trauma (AHT) to a hospital child protection team in Auckland, New Zealand. Methods Comparative review of demographics, histories, injuries, investigations and diagnostic outcomes for referrals under 15 years old from 1991 to 2010. Results Records were available for 345 children. Referrals increased markedly (88 in the first decade, 257 in the second), but the diagnostic ratio was stable: AHT 60%, accidental or natural 29% and uncertain cause 11%. The probability of AHT was similar regardless of socio-economic status or ethnicity. In children under 2 years old with accidental head injuries (75/255, 29%) or AHT (180/255, 71%), characteristics of particular interest for AHT included no history of trauma (88/98, 90%), no evidence of impact to the head (84/93, 90%), complex skull fractures with intracranial injury (22/28, 79%), subdural haemorrhage (160/179, 89%) and hypoxic ischaemic injury (38/39, 97%). In children over 2 years old, these characteristics did not differ significantly between children with accidental head injuries (21/47, 45%) and AHT (26/47, 55%). The mortality of AHT was higher in children over 2 years old (10/26, 38%) than under 2 years (19/180, 11%). Conclusions The striking increase in referrals for AHT probably represents increasing incidence. The decision to refer a hospitalised child with a head injury for assessment for possible AHT should not be influenced by socio-economic status or ethnicity. Children over 2 years old hospitalised for AHT are usually injured by mechanisms involving impact and should be considered at high risk of death. PMID:26130384

  17. Evaluation of the Self-Nulling Rotating Eddy Current Probe System

    NASA Technical Reports Server (NTRS)

    Hagemaier, Don; Rengel, Kent; Wincheski, Buzz; Namkung, Min

    1999-01-01

    In order to detect multi-site fatigue cracks located under flush-head rivets, automated eddy current equipment is required. To assure a reliable system, the eddy current probe must be centered easily over the installed rivets. To meet these requirements, the NDE Group at NASA LaRC developed the Self-Nulling Rotating Eddy Current Probe System (SNRECPS) which will be referred to as RPS in this document. The system was evaluated at the FAA, NDI Validation Center, in Albuquerque, New Mexico. The system was capable of detecting a 0.032 inch long crack with a 90/95% PoD. Further evaluations were conducted at Boeing in Long Beach, California. These evaluations included fatigue cracks and notches in a range from 0.025 to 0.100 inch long under flush-head aluminum rivets, and titanium or steel flush-head fasteners. The results of these tests are reported herein. Subsequently, the system was loaned to the USAF Structures Laboratory for the purpose of detecting and measuring short cracks under flush-head rivets in a variety of fatigue test specimens. The inspection task was to detect and plot crack growth from numbered fasteners in lettered rows. In January, 1998, the system was taken to Northwest Airlines Maintenance Base, in Atlanta, to inspect a DC-9, for multi-site cracks in three circumferential splices. The aircraft had 83,000 cycles. The inspection was conducted at 30 kHz from longeron 5 left to longeron 5 right. The system was calibrated using a 0,030 EDM first layer notch. The instrument gain was set to 19 mV from the notch. The reject level was set at 10 mV and the unflawed fasteners yielded a signal amplitude of 2 to 3 mV. Only one fastener location, out of about 2,500 tested, yielded a signal of 58 mV. The rivet was removed and visually evaluated. It appeared to be a slight gouge in the counter-sink zone. No fatigue cracks were detected. The same fastener locations were also inspected using the Boeing MAUS system at 60 kHz. No cracks were detected. Thus far, the rotating probe eddy current system has been found to be very user friendly and capable of detecting first layer cracks on the order of 0.030 inch long or longer.

  18. 46 CFR 52.01-95 - Design (modifies PG-16 through PG-31 and PG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... exceeding 525 °F. Refer to § 56.30-30(b)(1) of this subchapter for applicable requirements. (e) Stresses. (Modifies PG-22.) The stresses due to hydrostatic head shall be taken into account in determining the... stresses, imposed by effects other than internal pressure or static head, which increase the average stress...

  19. Raising Pupil Attainment through Family Learning: A Guide for Head Teachers and School Governors

    ERIC Educational Resources Information Center

    Learning and Work Institute, 2016

    2016-01-01

    This guide is for head teachers and school governors to help them invest their Pupil Premium funding in Family Learning programmes. The Pupil Premium is additional funding for schools in England to raise the attainment of disadvantaged pupils and close the gap between them and their peers. Family Learning is a pedagogical approach that refers to…

  20. Users' Manual for Research: Translating Head Start Findings Into Action (Expanded Notebook Version).

    ERIC Educational Resources Information Center

    Grotberg, Edith H.; Fowler, Austine

    This users' manual, intended for use with a Project Head Start teacher training notebook, describes the purpose, development and field testing of the training materials and suggests procedures for using the notebook as a resource in teacher training sessions. The training notebook to which the users' manual refers is based on 11 questions in the…

  1. 46 CFR 52.01-95 - Design (modifies PG-16 through PG-31 and PG-100).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... exceeding 525 °F. Refer to § 56.30-30(b)(1) of this subchapter for applicable requirements. (e) Stresses. (Modifies PG-22.) The stresses due to hydrostatic head shall be taken into account in determining the... stresses, imposed by effects other than internal pressure or static head, which increase the average stress...

  2. CAD/CAM (Computer Aided Design/Computer Aided Manufacture). A Brief Guide to Materials in the Library of Congress.

    ERIC Educational Resources Information Center

    Havas, George D.

    This brief guide to materials in the Library of Congress (LC) on computer aided design and/or computer aided manufacturing lists reference materials and other information sources under 13 headings: (1) brief introductions; (2) LC subject headings used for such materials; (3) textbooks; (4) additional titles; (5) glossaries and handbooks; (6)…

  3. 46 CFR 52.01-95 - Design (modifies PG-16 through PG-31 and PG-100).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... exceeding 525 °F. Refer to § 56.30-30(b)(1) of this subchapter for applicable requirements. (e) Stresses. (Modifies PG-22.) The stresses due to hydrostatic head shall be taken into account in determining the... stresses, imposed by effects other than internal pressure or static head, which increase the average stress...

  4. 49 CFR 572.100 - Incorporation by Reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of the materials may be inspected at NHTSA's Docket... 92041-018, “Head Form Bill of Materials,” (November 30, 1992); drawing number 78051-148, “Skull-Head... Skin Formulation Hybrid III,” (May 20, 1978); and drawing number C-1797, “Neck Blank, (August 1, 1989...

  5. 49 CFR 572.100 - Incorporation by Reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of the materials may be inspected at NHTSA's Docket... 92041-018, “Head Form Bill of Materials,” (November 30, 1992); drawing number 78051-148, “Skull-Head... Skin Formulation Hybrid III,” (May 20, 1978); and drawing number C-1797, “Neck Blank, (August 1, 1989...

  6. 49 CFR 572.100 - Incorporation by Reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of the materials may be inspected at NHTSA's Docket... 92041-018, “Head Form Bill of Materials,” (November 30, 1992); drawing number 78051-148, “Skull-Head... Skin Formulation Hybrid III,” (May 20, 1978); and drawing number C-1797, “Neck Blank, (August 1, 1989...

  7. [Funding of the management of severe malaria in children by Kinshasa households (Democratic Republic of Congo)].

    PubMed

    Ilunga-Ilunga, Félicien; Levêque, Alain; Dramaix, Michèle

    2015-01-01

    The objective of this study was to determine the source of health care funding for heads of households related to the management of severe malaria in children admitted to a Kinshasa reference hospital. This cross-sectional study was conducted on 1,350 hospitalised children under the age of 15 years treated for severe malaria in Kinshasa reference hospitals from January to November 2011 and the heads of households of these children. Only 46% of heads of households reported having sufficient funds directly available in the household budget. The remaining 54% had to call upon external sources of funding (sale of assets, loans, pawning goods). The use of a loan tended to increase significantly mainly for households with a low (adjusted odds ratio = 6.2), and intermediate socioeconomic status (adjusted odds ratio = 3.8) and for households working in the informal sector (adjusted odds ratio = 2.5). Similarly, the sale of assets was more frequently reported for households working in the informal sector (adjusted odds ratio = 2.4) and for female heads of households (adjusted odds ratio = 3.9). The management of severe malaria is a burden on household income. The majority of heads of households concerned needs to use external funding sources. A State subsidy for this management would help to reduce the risk of debt and sale of assets, especially for the poorest households.

  8. A DDC Bibliography on Computers in Information Sciences. Volume II. Information Sciences Series.

    ERIC Educational Resources Information Center

    Defense Documentation Center, Alexandria, VA.

    The unclassified and unlimited bibliography compiles references dealing specifically with the role of computers in information sciences. The volume contains 239 annotated references grouped under three major headings: Artificial and Programming Languages, Computer Processing of Analog Data, and Computer Processing of Digital Data. The references…

  9. Russian Literature: A Guide to Reference Sources.

    ERIC Educational Resources Information Center

    McGill Univ., Montreal (Quebec). McLennan Library.

    An annotated bibliography of general and specialized reference works for Russian and Soviet literature is intended for both students and researchers. English language and Russian language sources in the McGill University (Canada) libraries are included. Subject headings include guides (to the literature and to archival resources), encyclopedias,…

  10. Head rice rate measurement based on concave point matching

    PubMed Central

    Yao, Yuan; Wu, Wei; Yang, Tianle; Liu, Tao; Chen, Wen; Chen, Chen; Li, Rui; Zhou, Tong; Sun, Chengming; Zhou, Yue; Li, Xinlu

    2017-01-01

    Head rice rate is an important factor affecting rice quality. In this study, an inflection point detection-based technology was applied to measure the head rice rate by combining a vibrator and a conveyor belt for bulk grain image acquisition. The edge center mode proportion method (ECMP) was applied for concave points matching in which concave matching and separation was performed with collaborative constraint conditions followed by rice length calculation with a minimum enclosing rectangle (MER) to identify the head rice. Finally, the head rice rate was calculated using the sum area of head rice to the overall coverage of rice. Results showed that bulk grain image acquisition can be realized with test equipment, and the accuracy rate of separation of both indica rice and japonica rice exceeded 95%. An increase in the number of rice did not significantly affect ECMP and MER. High accuracy can be ensured with MER to calculate head rice rate by narrowing down its relative error between real values less than 3%. The test results show that the method is reliable as a reference for head rice rate calculation studies. PMID:28128315

  11. Nature and origins of virtual environments - A bibliographical essay

    NASA Technical Reports Server (NTRS)

    Ellis, S. R.

    1991-01-01

    Virtual environments presented via head-mounted, computer-driven displays provide a new media for communication. They may be analyzed by considering: (1) what may be meant by an environment; (2) what is meant by the process of virtualization; and (3) some aspects of human performance that constrain environmental design. Their origins are traced from previous work in vehicle simulation and multimedia research. Pointers are provided to key technical references, in the dispersed, archival literature, that are relevant to the development and evaluation of virtual-environment interface systems.

  12. Numerical assessment of the performance of a scalp-implantable antenna: effects of head anatomy and dielectric parameters.

    PubMed

    Kiourti, Asimina; Nikita, Konstantina S

    2013-04-01

    We numerically assess the effects of head properties (anatomy and dielectric parameters) on the performance of a scalp-implantable antenna for telemetry in the Medical Implant Communications Service band (402.0-405.0 MHz). Safety issues and performance (resonance, radiation) are analyzed for an experimentally validated implantable antenna (volume of 203.6 mm(3) ), considering five head models (3- and 5-layer spherical, 6-, 10-, and 13-tissue anatomical) and seven scenarios (variations ± 20% in the reference permittivity and conductivity values). Simulations are carried out at 403.5 MHz using the finite-difference time-domain method. Anatomy of the head model around the implantation site is found to mainly affect antenna performance, whereas overall tissue anatomy and dielectric parameters are less significant. Compared to the reference dielectric parameter scenario within the 3-layer spherical head, maximum variations of -19.9%, +3.7%, -55.1%, and -39.2% are computed in the maximum allowable net input power imposed by the IEEE Std C95.1-1999 and Std C95.1-2005 safety guidelines, return loss, and maximum far-field gain, respectively. Compliance with the recent IEEE Std C95.1-2005 is found to be almost insensitive to head properties, in contrast with IEEE Std C95.1-1999. Taking tissue property uncertainties into account is highlighted as crucial for implantable antenna design and performance assessment. Bioelectromagnetics 34:167-179, 2013. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.

  13. Hemodynamic measurements in deep brain tissues of humans by near-infrared time-resolved spectroscopy

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiroaki; Oda, Motoki; Yamaki, Etsuko; Suzuki, Toshihiko; Yamashita, Daisuke; Yoshimoto, Kenji; Homma, Shu; Yamashita, Yutaka

    2014-03-01

    Using near-infrared time-resolved spectroscopy (TRS), we measured the human head in transmittance mode to obtain the optical properties, tissue oxygenation, and hemodynamics of deep brain tissues in 50 healthy adult volunteers. The right ear canal was irradiated with 3-wavelengths of pulsed light (760, 795, and 835nm), and the photons passing through the human head were collected at the left ear canal. Optical signals with sufficient intensity could be obtained from 46 of the 50 volunteers. By analyzing the temporal profiles based on the photon diffusion theory, we successfully obtained absorption coefficients for each wavelength. The levels of oxygenated hemoglobin (HbO2), deoxygenated hemoglobin (Hb), total hemoglobin (tHb), and tissue oxygen saturation (SO2) were then determined by referring to the hemoglobin spectroscopic data. Compared with the SO2 values for the forehead measurements in reflectance mode, the SO2 values of the transmittance measurements of the human head were approximately 10% lower, and tHb values of the transmittance measurements were always lower than those of the forehead reflectance measurements. Moreover, the level of hemoglobin and the SO2 were strongly correlated between the human head measurements in transmittance mode and the forehead measurements in the reflectance mode, respectively. These results demonstrated a potential application of this TRS system in examining deep brain tissues of humans.

  14. Anterior approach versus posterior approach for Pipkin I and II femoral head fractures: A systemic review and meta-analysis.

    PubMed

    Wang, Chen-guang; Li, Yao-min; Zhang, Hua-feng; Li, Hui; Li, Zhi-jun

    2016-03-01

    We performed a meta-analysis, pooling the results from controlled clinical trials to compare the efficiency of anterior and posterior surgical approaches to Pipkin I and II fractures of the femoral head. Potential academic articles were identified from the Cochrane Library, Medline (1966-2015.5), PubMed (1966-2015.5), Embase (1980-2015.5) and ScienceDirect (1966-2015.5) databases. Gray studies were identified from the references of the included literature. Pooling of the data was performed and analyzed by RevMan software, version 5.1. Five case-control trials (CCTs) met the inclusion criteria. There were significant differences in the incidence of heterotopic ossification (HO) between the approaches, but no significant differences were found between the two groups regarding functional outcomes of the hip, general postoperative complications, osteonecrosis of the femoral head or post-traumatic arthritis. The present meta-analysis indicated that the posterior approach decreased the risk of heterotopic ossification compared with the anterior approach for the treatment of Pipkin I and II femoral head fractures. No other complications were related to anterior and posterior approaches. Future high-quality randomized, controlled trials (RCTs) are needed to determine the optimal surgical approach and to predict other postoperative complications. III. Copyright © 2016 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Persson, Mats, E-mail: mats.persson@mi.physics.kth

    Purpose: The highest photon fluence rate that a computed tomography (CT) detector must be able to measure is an important parameter. The authors calculate the maximum transmitted fluence rate in a commercial CT scanner as a function of patient size for standard head, chest, and abdomen protocols. Methods: The authors scanned an anthropomorphic phantom (Kyoto Kagaku PBU-60) with the reference CT protocols provided by AAPM on a GE LightSpeed VCT scanner and noted the tube current applied with the tube current modulation (TCM) system. By rescaling this tube current using published measurements on the tube current modulation of a GEmore » scanner [N. Keat, “CT scanner automatic exposure control systems,” MHRA Evaluation Report 05016, ImPACT, London, UK, 2005], the authors could estimate the tube current that these protocols would have resulted in for other patient sizes. An ECG gated chest protocol was also simulated. Using measured dose rate profiles along the bowtie filters, the authors simulated imaging of anonymized patient images with a range of sizes on a GE VCT scanner and calculated the maximum transmitted fluence rate. In addition, the 99th and the 95th percentiles of the transmitted fluence rate distribution behind the patient are calculated and the effect of omitting projection lines passing just below the skin line is investigated. Results: The highest transmitted fluence rates on the detector for the AAPM reference protocols with centered patients are found for head images and for intermediate-sized chest images, both with a maximum of 3.4 ⋅ 10{sup 8} mm{sup −2} s{sup −1}, at 949 mm distance from the source. Miscentering the head by 50 mm downward increases the maximum transmitted fluence rate to 5.7 ⋅ 10{sup 8} mm{sup −2} s{sup −1}. The ECG gated chest protocol gives fluence rates up to 2.3 ⋅ 10{sup 8} − 3.6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} depending on miscentering. Conclusions: The fluence rate on a CT detector reaches 3 ⋅ 10{sup 8} − 6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} in standard imaging protocols, with the highest rates occurring for ECG gated chest and miscentered head scans. These results will be useful to developers of CT detectors, in particular photon counting detectors.« less

  16. SU-F-T-315: Comparative Studies of Planar Dose with Different Spatial Resolution for Head and Neck IMRT QA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hwang, T; Koo, T

    Purpose: To quantitatively investigate the planar dose difference and the γ value between the reference fluence map with the 1 mm detector-to-detector distance and the other fluence maps with less spatial resolution for head and neck intensity modulated radiation (IMRT) therapy. Methods: For ten head and neck cancer patients, the IMRT quality assurance (QA) beams were generated using by the commercial radiation treatment planning system, Pinnacle3 (ver. 8.0.d Philips Medical System, Madison, WI). For each beam, ten fluence maps (detector-to-detector distance: 1 mm to 10 mm by 1 mm) were generated. The fluence maps with larger than 1 mm detector-todetectormore » distance were interpolated using MATLAB (R2014a, the Math Works,Natick, MA) by four different interpolation Methods: for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. These interpolated fluence maps were compared with the reference one using the γ value (criteria: 3%, 3 mm) and the relative dose difference. Results: As the detector-to-detector distance increases, the dose difference between the two maps increases. For the fluence map with the same resolution, the cubic spline interpolation and the bicubic interpolation are almost equally best interpolation methods while the nearest neighbor interpolation is the worst.For example, for 5 mm distance fluence maps, γ≤1 are 98.12±2.28%, 99.48±0.66%, 99.45±0.65% and 82.23±0.48% for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. For 7 mm distance fluence maps, γ≤1 are 90.87±5.91%, 90.22±6.95%, 91.79±5.97% and 71.93±4.92 for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. Conclusion: We recommend that the 2-dimensional detector array with high spatial resolution should be used as an IMRT QA tool and that the measured fluence maps should be interpolated using by the cubic spline interpolation or the bicubic interpolation for head and neck IMRT delivery. This work was supported by Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)« less

  17. Study of the Time Response of a Simulated Hydroelectric System

    NASA Astrophysics Data System (ADS)

    Simani, S.; Alvisi, S.; Venturini, M.

    2014-12-01

    This paper addresses the design of an advanced control strategy for a typical hydroelectric dynamic process, performed in the Matlab and Simulink environments. The hydraulic system consists of a high water head and a long penstock with upstream and downstream surge tanks, and is equipped with a Francis turbine. The nonlinear characteristics of hydraulic turbine and the inelastic water hammer effects were considered to calculate and simulate the hydraulic transients. With reference to the control solution, the proposed methodology relies on an adaptive control designed by means of the on-line identification of the system model under monitoring. Extensive simulations and comparison with respect to a classic hydraulic turbine speed PID regulator show the effectiveness of the proposed modelling and control tools.

  18. Effects of head orientation and lateral body tilt on egocentric coding: cognitive and sensory-motor accuracy.

    PubMed

    Prieur, J-M; Bourdin, C; Sarès, F; Vercher, J-L

    2006-01-01

    A major issue in motor control studies is to determine whether and how we use spatial frames of reference to organize our spatially oriented behaviors. In previous experiments we showed that simulated body tilt during off-axis rotation affected the performance in verbal localization and manual pointing tasks. It was hypothesized that the observed alterations were at least partly due to a change in the orientation of the egocentric frame of reference, which was indeed centered on the body but aligned with the gravitational vector. The present experiments were designed to test this hypothesis in a situation where no inertial constraints (except the usual gravitational one) exist and where the orientation of the body longitudinal z-axis was not aligned with the direction of the gravity. Eleven subjects were exposed to real static body tilt and were required to verbally localize (experiment 1) and to point as accurately as possible towards (experiment 2) memorized visual targets, in two conditions, Head-Free and Head-Fixed conditions. Results show that the performance was only affected by real body tilt in the localization task performed when the subject's head was tilted relative to the body. Thus, dissociation between gravity and body longitudinal z-axis alone is not responsible for localization nor for pointing errors. Therefore, the egocentric frame of reference seems independent from the orientation of the gravity with regard to body z-axis as expected from our previous studies. Moreover, the use of spatial referentials appears to be less mandatory than expected for pointing movements (motor task) than for localization task (cognitive task).

  19. Optical See-Through Head Mounted Display Direct Linear Transformation Calibration Robustness in the Presence of User Alignment Noise

    NASA Technical Reports Server (NTRS)

    Axholt, Magnus; Skoglund, Martin; Peterson, Stephen D.; Cooper, Matthew D.; Schoen, Thomas B.; Gustafsson, Fredrik; Ynnerman, Anders; Ellis, Stephen R.

    2010-01-01

    Augmented Reality (AR) is a technique by which computer generated signals synthesize impressions that are made to coexist with the surrounding real world as perceived by the user. Human smell, taste, touch and hearing can all be augmented, but most commonly AR refers to the human vision being overlaid with information otherwise not readily available to the user. A correct calibration is important on an application level, ensuring that e.g. data labels are presented at correct locations, but also on a system level to enable display techniques such as stereoscopy to function properly [SOURCE]. Thus, vital to AR, calibration methodology is an important research area. While great achievements already have been made, there are some properties in current calibration methods for augmenting vision which do not translate from its traditional use in automated cameras calibration to its use with a human operator. This paper uses a Monte Carlo simulation of a standard direct linear transformation camera calibration to investigate how user introduced head orientation noise affects the parameter estimation during a calibration procedure of an optical see-through head mounted display.

  20. Ionization-chamber smoke detector system

    DOEpatents

    Roe, Robert F.

    1976-10-19

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system is designed to reduce false alarms caused by fluctuations in ambient temperature. Means are provided for periodically firing the gas discharge triode and each time recording the triggering voltage required. A computer compares each triggering voltage with its predecessor. The computer is programmed to energize an alarm if the difference between the two compared voltages is a relatively large value indicative of particulates in the measuring chamber and to disregard smaller differences typically resulting from changes in ambient temperature.

  1. Benchmarking of Advanced Control Strategies for a Simulated Hydroelectric System

    NASA Astrophysics Data System (ADS)

    Finotti, S.; Simani, S.; Alvisi, S.; Venturini, M.

    2017-01-01

    This paper analyses and develops the design of advanced control strategies for a typical hydroelectric plant during unsteady conditions, performed in the Matlab and Simulink environments. The hydraulic system consists of a high water head and a long penstock with upstream and downstream surge tanks, and is equipped with a Francis turbine. The nonlinear characteristics of hydraulic turbine and the inelastic water hammer effects were considered to calculate and simulate the hydraulic transients. With reference to the control solutions addressed in this work, the proposed methodologies rely on data-driven and model-based approaches applied to the system under monitoring. Extensive simulations and comparisons serve to determine the best solution for the development of the most effective, robust and reliable control tool when applied to the considered hydraulic system.

  2. Genetic diversity of the human head lice, Pediculus humanus capitis, among primary school girls in Saudi Arabia, with reference to their prevalence.

    PubMed

    Al-Shahrani, Sarah A; Alajmi, Reem A; Ayaad, Tahany H; Al-Shahrani, Mohammed A; Shaurub, El-Sayed H

    2017-10-01

    The present work aimed at investigating the genetic diversity of the head louse Pediculus humanus capitis (P. humanus capitis) among infested primary school girls at Bisha governorate, Saudi Arabia, based on the sequence of mitochondrial cytochrome b (mt cyt b) gene of 121 P. humanus capitis adults. Additionally, the prevalence of pediculosis capitis was surveyed. The results of sequencing were compared with the sequence of human head lice that are genotyped previously. Phylogenetic tree analysis showed the presence of 100% identity (n = 26) of louse specimens with clade A (prevalent worldwide) of the GenBank data base. Louse individuals (n = 50) showed 99.8% similarity with the same clade A reference having a single base pair difference. Also, a number of 22 louse individuals revealed 99.8% identity with clade B reference (prevalent in North and Central Americas, Europe, and Australia) with individual diversity in two base pairs. Moreover, 14 louse individual sequences revealed 99.4% identity with three base pair differences. It was concluded that moderate pediculosis (~13%) prevailed among the female students of the primary schools. It was age-and hair texture (straight or curly)-dependent. P. humanus capitis prevalence diversity is of clades A and B genotyping.

  3. Girls in Schools: A Bibliography of Research on Girls in U.S. Public Schools Kindergarten through Grade 12. Third Edition.

    ERIC Educational Resources Information Center

    Wellesley Coll., MA. Center for Research on Women.

    This bibliography focuses on girls in public schools from preschool through 12th grade. Some citations referring to research on college students have been included because they have particular relevance for earlier schooling. The citations are arranged by topic headings. Each topic heading contains five categories: (1) books and book chapters, (2)…

  4. Body Weight, Length and Head Circumference at Birth in a Cohort of Turkish Newborns

    PubMed Central

    Kurtoğlu, Selim; Hatipoğlu, Nihal; Mazıcıoğlu, Mustafa Mümtaz; Akın, Mustafa Ali; Çoban, Dilek; Gökoğlu, Sonay; Baştuğ, Osman

    2012-01-01

    Objective: Intrauterine growth references are primarily useful indicators in the assessment of the general health status of newborn infants. Although Lubchenco’s references are still used in many neonatal care units, we believe that there is a need for up-to-date intrauterine growth references specific for different populations. To develop gestational age-and gender-specific national references for birth weight, birth length and head circumference. Methods: Data were collected from neonatal records of perinatology services of eleven hospitals from January to December 2009. The anthropometry of a total of 4750 singleton live births born between 28 and 41 weeks of gestation were recorded. Means and standard deviations were calculated, and percentiles for each gender and gestational week were produced using the LMS program. The results were compared with US infants and also with local data. Results: Gestational age- and gender-specific 3rd, 5th, 10th, 15th, 25th, 50th, 75th, 85th, 90th, 95th and 97th percentile values were produced. Comparison of the 10th, 50th and 90th percentile values showed that the boys were heavier and longer than the girls. Head circumference values were also higher in the boys. Proportions of small for gestational age (SGA), appropriate for gestational age (AGA) and large for gestational age (LGA) infants in the sample were 10.1%, 79.1% and 10.8%, respectively. Conclusion: These gender- and gestational age-specific references will be of use in clinical practice and also for research purposes until more comprehensive, reliable and accessible national data pertaining to the intrauterine growth of Turkish infants are produced. Conflict of interest:None declared. PMID:22664362

  5. Intensity- and energy-modulated electron radiotherapy by means of an xMLC for head and neck shallow tumors

    NASA Astrophysics Data System (ADS)

    Salguero, Francisco Javier; Arráns, Rafael; Atriana Palma, Bianey; Leal, Antonio

    2010-03-01

    The purpose of this paper is to assess the feasibility of delivering intensity- and energy-modulated electron radiation treatment (MERT) by a photon multileaf collimator (xMLC) and to evaluate the improvements obtained in shallow head and neck (HN) tumors. Four HN patient cases covering different clinical situations were planned by MERT, which used an in-house treatment planning system that utilized Monte Carlo dose calculation. The cases included one oronasal, two parotid and one middle ear tumors. The resulting dose-volume histograms were compared with those obtained from conventional photon and electron treatment techniques in our clinic, which included IMRT, electron beam and mixed beams, most of them using fixed-thickness bolus. Experimental verification was performed with plane-parallel ionization chambers for absolute dose verification, and a PTW ionization chamber array and radiochromic film for relative dosimetry. A MC-based treatment planning system for target with compromised volumes in depth and laterally has been validated. A quality assurance protocol for individual MERT plans was launched. Relative MC dose distributions showed a high agreement with film measurements and absolute ion chamber dose measurements performed at a reference point agreed with MC calculations within 2% in all cases. Clinically acceptable PTV coverage and organ-at-risk sparing were achieved by using the proposed MERT approach. MERT treatment plans, based on delivery of intensity-modulated electron beam using the xMLC, for superficial head and neck tumors, demonstrated comparable or improved PTV dose homogeneity with significantly lower dose to normal tissues. The clinical implementation of this technique will be able to offer a viable alternative for the treatment of shallow head and neck tumors.

  6. Large Diameter Femoral Heads Impose Significant Alterations on the Strains Developed on Femoral Component and Bone: A Finite Element Analysis

    PubMed Central

    Theodorou, E.G; Provatidis, C.G; Babis, G.C; Georgiou, C.S; Megas, P.D

    2011-01-01

    Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost’s law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used. PMID:21792381

  7. Large diameter femoral heads impose significant alterations on the strains developed on femoral component and bone: a finite element analysis.

    PubMed

    Theodorou, E G; Provatidis, C G; Babis, G C; Georgiou, C S; Megas, P D

    2011-01-01

    Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost's law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used.

  8. Attitude ground support system for the solar maximum mission spacecraft

    NASA Technical Reports Server (NTRS)

    Nair, G.

    1980-01-01

    The SMM attitude ground support system (AGSS) supports the acquisition of spacecraft roll attitude reference, performs the in-flight calibration of the attitude sensor complement, supports onboard control autonomy via onboard computer data base updates, and monitors onboard computer (OBC) performance. Initial roll attitude acquisition is accomplished by obtaining a coarse 3 axis attitude estimate from magnetometer and Sun sensor data and subsequently refining it by processing data from the fixed head star trackers. In-flight calibration of the attitude sensor complement is achieved by processing data from a series of slew maneuvers designed to maximize the observability and accuracy of the appropriate alignments and biases. To ensure autonomy of spacecraft operation, the AGSS selects guide stars and computes sensor occultation information for uplink to the OBC. The onboard attitude control performance is monitored on the ground through periodic attitude determination and processing of OBC data in downlink telemetry. In general, the control performance has met mission requirements. However, software and hardware problems have resulted in sporadic attitude reference losses.

  9. Space shuttle propulsion estimation development verification

    NASA Technical Reports Server (NTRS)

    Rogers, Robert M.

    1989-01-01

    The application of extended Kalman filtering to estimating the Space Shuttle Propulsion performance, i.e., specific impulse, from flight data in a post-flight processing computer program is detailed. The flight data used include inertial platform acceleration, SRB head pressure, SSME chamber pressure and flow rates, and ground based radar tracking data. The key feature in this application is the model used for the SRB's, which is a nominal or reference quasi-static internal ballistics model normalized to the propellant burn depth. Dynamic states of mass overboard and propellant burn depth are included in the filter model to account for real-time deviations from the reference model used. Aerodynamic, plume, wind and main engine uncertainties are also included for an integrated system model. Assuming uncertainty within the propulsion system model and attempts to estimate its deviations represent a new application of parameter estimation for rocket powered vehicles. Illustrations from the results of applying this estimation approach to several missions show good quality propulsion estimates.

  10. Fetal Growth and Birth Anthropometrics in Metformin-Exposed Offspring Born to Mothers With PCOS.

    PubMed

    Hjorth-Hansen, Anna; Salvesen, Øyvind; Engen Hanem, Liv Guro; Eggebø, Torbjørn; Salvesen, Kjell Å; Vanky, Eszter; Ødegård, Rønnaug

    2018-02-01

    Metformin is used in an attempt to reduce pregnancy complications associated with polycystic ovary syndrome (PCOS). Little is known about the effect of metformin on fetal development and growth. To compare the effect of metformin versus placebo on fetal growth and birth anthropometrics in PCOS offspring compared with a reference population in relation to maternal body mass index (BMI). Post hoc analysis of a randomized controlled trial. Double-blind, placebo-controlled, multicenter study. 258 offspring born to mothers with PCOS. 2000 mg metformin (n = 131) or placebo (n = 121) from first trimester to delivery. Mean abdominal diameter and biparietal diameter (BPD) at gestational weeks 19 and 32. Head circumference (HC), birth length, and weight related to a reference population of healthy offspring, expressed as gestational age- and sex-adjusted z-scores. Metformin- versus placebo-exposed offspring had larger heads at gestational week 32 (BPD, 86.1 mm versus 85.2 mm; P = 0.03) and at birth (HC, 35.6 cm versus 35.1 cm; P < 0.01). Analyses stratified by maternal prepregnancy BMI, larger heads were observed only among offspring of overweight/obese mothers. Among normal-weight mothers, the effect of metformin compared with placebo was reduced length (z-score = -0.96 versus -0.42, P = 0.04) and weight (z-score = -0.44 versus 0.02; P = 0.03). Compared with the reference population, offspring born to PCOS mothers (placebo group) had reduced length (z-score = -0.40; 95% confidence interval, -0.60 to -0.40), but similar birth weight and HC. Metformin exposure resulted in larger head size in offspring of overweight mothers, traceable already in utero. Maternal prepregnancy BMI modified the effect of metformin on offspring anthropometrics. Anthropometrics of offspring born to PCOS mothers differed from those of the reference population. Copyright © 2017 Endocrine Society

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ranganathan, V; Kumar, P; Bzdusek, K

    Purpose: We propose a novel data-driven method to predict the achievability of clinical objectives upfront before invoking the IMRT optimization. Methods: A new metric called “Geometric Complexity (GC)” is used to estimate the achievability of clinical objectives. Here, GC is the measure of the number of “unmodulated” beamlets or rays that intersect the Region-of-interest (ROI) and the target volume. We first compute the geometric complexity ratio (GCratio) between the GC of a ROI (say, parotid) in a reference plan and the GC of the same ROI in a given plan. The GCratio of a ROI indicates the relative geometric complexitymore » of the ROI as compared to the same ROI in the reference plan. Hence GCratio can be used to predict if a defined clinical objective associated with the ROI can be met by the optimizer for a given case. Basically a higher GCratio indicates a lesser likelihood for the optimizer to achieve the clinical objective defined for a given ROI. Similarly, a lower GCratio indicates a higher likelihood for the optimizer to achieve the clinical objective defined for the given ROI. We have evaluated the proposed method on four Head and Neck cases using Pinnacle3 (version 9.10.0) Treatment Planning System (TPS). Results: Out of the total of 28 clinical objectives from four head and neck cases included in the study, 25 were in agreement with the prediction, which implies an agreement of about 85% between predicted and obtained results. The Pearson correlation test shows a positive correlation between predicted and obtained results (Correlation = 0.82, r2 = 0.64, p < 0.005). Conclusion: The study demonstrates the feasibility of the proposed method in head and neck cases for predicting the achievability of clinical objectives with reasonable accuracy.« less

  12. Updating of the spatial reference frame of head direction cells in response to locomotion in the vertical plane

    PubMed Central

    Wang, Sarah S.; Kim, Stanley Y.; Frohardt, Russell J.

    2013-01-01

    Many species navigate in three dimensions and are required to maintain accurate orientation while moving in an Earth vertical plane. Here we explored how head direction (HD) cells in the rat anterodorsal thalamus responded when rats locomoted along a 360° spiral track that was positioned vertically within the room at the N, S, E, or W location. Animals were introduced into the vertical plane either through passive placement (experiment 1) or by allowing them to run up a 45° ramp from the floor to the vertically positioned platform (experiment 2). In both experiments HD cells maintained direction-specific firing in the vertical plane with firing properties that were indistinguishable from those recorded in the horizontal plane. Interestingly, however, the cells' preferred directions were linked to different aspects of the animal's environment and depended on how the animal transitioned into the vertical plane. When animals were passively placed onto the vertical surface, the cells switched from using the room (global cues) as a reference frame to using the vertically positioned platform (local cues) as a reference frame, independent of where the platform was located. In contrast, when animals self-locomoted into the vertical plane, the cells' preferred directions remained anchored to the three-dimensional room coordinates and their activity could be accounted for by a simple 90° rotation of the floor's horizontal coordinate system to the vertical plane. These findings highlight the important role that active movement signals play for maintaining and updating spatial orientation when moving in three dimensions. PMID:23114216

  13. Physical properties of the human head: mass, center of gravity and moment of inertia.

    PubMed

    Yoganandan, Narayan; Pintar, Frank A; Zhang, Jiangyue; Baisden, Jamie L

    2009-06-19

    This paper presents a synthesis of biomedical investigations of the human head with specific reference to certain aspects of physical properties and development of anthropometry data, leading to the advancement of dummies used in crashworthiness research. As a significant majority of the studies have been summarized as reports, an effort has been made to chronologically review the literature with the above objectives. The first part is devoted to early studies wherein the mass, center of gravity (CG), and moment of inertia (MOI) properties are obtained from human cadaver experiments. Unembalmed and preserved whole-body and isolated head and head-neck experiments are discussed. Acknowledging that the current version of the Hybrid III dummy is the most widely used anthropomorphic test device in motor vehicle crashworthiness research for frontal impact applications for over 30 years, bases for the mass and MOI-related data used in the dummy are discussed. Since the development and federalization of the dummy in the United States, description of methods used to arrive at these properties form a part of the manuscript. Studies subsequent to the development of this dummy including those from the US Military are also discussed. As the head and neck are coupled in any impact, and increasing improvements in technology such as advanced airbags, and pre-tensioners and load limiters in manual seatbelts affect the kinetics of the head-neck complex, the manuscript underscores the need to pursue studies to precisely determine all the physical properties of the head. Because the most critical parameters (locations of CG and occipital condyles (OC), mass, and MOI) have not been determined on a specimen-by-specimen basis in any single study, it is important to gather these data in future experiments. These critical data will be of value for improving occupant safety, designing advanced restraint systems, developing second generation dummies, and assessing the injury mitigating characteristics of modern vehicle components in all impact modalities.

  14. Supervisory Rotation: Impact on an Academic Library Reference Staff.

    ERIC Educational Resources Information Center

    Perdue, Bob; Piotrowski, Chris

    1986-01-01

    Presents results of managerial rotation program (librarians take turns on two-year cycle serving as department head) in medium-sized academic library reference department. An assessment of both the advantages and disadvantages of such a plan examines impact of this innovative and collegial management technique on staff, library, and patrons. (7…

  15. Development of a microcomputer-based magnetic heading sensor

    NASA Technical Reports Server (NTRS)

    Garner, H. D.

    1987-01-01

    This paper explores the development of a flux-gate magnetic heading reference using a single-chip microcomputer to process heading information and to present it to the pilot in appropriate form. This instrument is intended to replace the conventional combination of mechanical compass and directional gyroscope currently in use in general aviation aircraft, at appreciable savings in cost and reduction in maintenance. Design of the sensing element, the signal processing electronics, and the computer algorithms which calculate the magnetic heading of the aircraft from the magnetometer data have been integrated in such a way as to minimize hardware requirements and simplify calibration procedures. Damping and deviation errors are avoided by the inherent design of the device, and a technique for compensating for northerly-turning-error is described.

  16. Effect of gravito-inertial cues on the coding of orientation in pre-attentive vision.

    PubMed

    Stivalet, P; Marendaz, C; Barraclough, L; Mourareau, C

    1995-01-01

    To see if the spatial reference frame used by pre-attentive vision is specified in a retino-centered frame or in a reference frame integrating visual and nonvisual information (vestibular and somatosensory), subjects were centrifuged in a non-pendular cabin and were asked to search for a target distinguishable from distractors by difference in orientation (Treisman's "pop-out" paradigm [1]). In a control condition, in which subjects were sitting immobilized but not centrifuged, this task gave an asymmetric search pattern: Search was rapid and pre-attentional except when the target was aligned with the horizontal retinal/head axis, in which case search was slow and attentional (2). Results using a centrifuge showed that slow/serial search patterns were obtained when the target was aligned with the subjective horizontal axis (and not with the horizontal retinal/head axis). These data suggest that a multisensory reference frame is used in pre-attentive vision. The results are interpreted in terms of Riccio and Stoffregen's "ecological theory" of orientation in which the vertical and horizontal axes constitute independent reference frames (3).

  17. Opportunity Science Using the Juno Magnetometer Investigation Star Trackers

    NASA Astrophysics Data System (ADS)

    Joergensen, J. L.; Connerney, J. E.; Bang, A. M.; Denver, T.; Oliversen, R. J.; Benn, M.; Lawton, P.

    2013-12-01

    The magnetometer experiment onboard Juno is equipped with four non-magnetic star tracker camera heads, two of which reside on each of the magnetometer sensor optical benches. These are located 10 and 12 m from the spacecraft body at the end of one of the three solar panel wings. The star tracker, collectively referred to as the Advanced Stellar Compass (ASC), provides high accuracy attitude information for the magnetometer sensors throughout science operations. The star tracker camera heads are pointed +/- 13 deg off the spin vector, in the anti-sun direction, imaging a 13 x 20 deg field of view every ¼ second as Juno rotates at 1 or 2 rpm. The ASC is a fully autonomous star tracker, producing a time series of attitude quaternions for each camera head, utilizing a suite of internal support functions. These include imaging capabilities, autonomous object tracking, automatic dark-sky monitoring, and related capabilities; these internal functions may be accessed via telecommand. During Juno's cruise phase, this capability can be tapped to provide unique science and engineering data available along the Juno trajectory. We present a few examples of the JUNO ASC opportunity science here. As the Juno spacecraft approached the Earth-Moon system for the close encounter with the Earth on October 9, 2013, one of the ASC camera heads obtained imagery of the Earth-Moon system while the other three remained in full science (attitude determination) operation. This enabled the first movie of the Earth and Moon obtained by a spacecraft flying past the Earth in gravity assist. We also use the many artificial satellites in orbit about the Earth as calibration targets for the autonomous asteroid detection system inherent to the ASC autonomous star tracker. We shall also profile the zodiacal dust disk, using the interstellar image data, and present the outlook for small asteroid body detection and distribution being performed during Juno's passage from Earth flyby to Jovian orbit insertion.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitledge, T.E.; Malloy, S.C.; Patton, C.J.

    This manual was assembled for use as a guide for analyzing the nutrient content of seawater samples collected in the marine coastal zone of the Northeast United States and the Bering Sea. Some modifications (changes in dilution or sample pump tube sizes) may be necessary to achieve optimum measurements in very pronounced oligotrophic, eutrophic or brackish areas. Information is presented under the following section headings: theory and mechanics of automated analysis; continuous flow system description; operation of autoanalyzer system; cookbook of current nutrient methods; automated analyzer and data analysis software; computer interfacing and hardware modifications; and trouble shooting. The threemore » appendixes are entitled: references and additional reading; manifold components and chemicals; and software listings. (JGB)« less

  19. Isodose atlas for use in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemeth, G.; Kuttig, H.

    1981-01-01

    This atlas is divided into 11 major sections: the skin, head and neck, thorax, breast, GI tract and extraintestinal abdominal organs, female genital organs, male genital organs, urinary tract, para-aortic lymph nodes, skeletal system, and central nervous system. It is intended as a handbook to aid the practicing radiotherapist in planning the radiation therapy of tumors of individual organs. The authors stress that they have obviously been unable to supply optimum isodose charts for each and every patient, but by judicious use of the charts, the legends that accompany the charts, and the exhaustive references provided at the end ofmore » the book, it should be possible to plan radiation therapy for most tumors.« less

  20. Injury Risk Assessment of Non-Lethal Projectile Head Impacts

    PubMed Central

    Oukara, Amar; Nsiampa, Nestor; Robbe, Cyril; Papy, Alexandre

    2014-01-01

    Kinetic energy non-lethal projectiles are used to impart sufficient effect onto a person in order to deter uncivil or hazardous behavior with a low probability of permanent injury. Since their first use, real cases indicate that the injuries inflicted by such projectiles may be irreversible and sometimes lead to death, especially for the head impacts. Given the high velocities and the low masses involved in such impacts, the assessment approaches proposed in automotive crash tests and sports may not be appropriate. Therefore, there is a need of a specific approach to assess the lethality of these projectiles. In this framework, some recent research data referred in this article as “force wall approach” suggest the use of three lesional thresholds (unconsciousness, meningeal damages and bone damages) that depend on the intracranial pressure. Three corresponding critical impact forces are determined for a reference projectile. Based on the principle that equal rigid wall maximal impact forces will produce equal damage on the head, these limits can be determined for any other projectile. In order to validate the consistence of this innovative method, it is necessary to compare the results with other existing assessment methods. This paper proposes a comparison between the “force wall approach” and two different head models. The first one is a numerical model (Strasbourg University Finite Element Head Model-SUFEHM) from Strasbourg University; the second one is a mechanical surrogate (Ballistics Load Sensing Headform-BLSH) from Biokinetics. PMID:25400712

  1. Natural head position: An overview.

    PubMed

    Meiyappan, N; Tamizharasi, S; Senthilkumar, K P; Janardhanan, K

    2015-08-01

    Cephalometrics has given us a different perspective of interpreting various skeletal problems in the dentofacial complex. Natural head position (NHP) is a reproducible, physiologically determined aspect of function. To determine NHP, a horizontal or vertical reference line outside the crania was used, but preference was given generally to the horizontal. Various intra and extracranial cephalometric horizontal reference planes have been used to formulate diagnosis and plan individualized treatment for an integrated correction of the malocclusion cephalometrics is constantly undergoing refinements in its techniques and analyses to improve the clinical applications. Even though various methods for establishing NHP have been proposed, still it remains a challenge to the clinicians to implement the concept of NHP thoroughly in all the stages of treatment because of practical difficulties in the clinical scenario.

  2. Scanning Optical Head with Nontilted Reference Beam: Assuring Nanoradian Accuracy for a New Generation Surface Profiler in the Large-Slope Testing Range

    DOE PAGES

    Qian, Shinan

    2011-01-01

    Nmore » anoradian Surface Profilers (SPs) are required for state-of-the-art synchrotron radiation optics and high-precision optical measurements. ano-radian accuracy must be maintained in the large-angle test range. However, the beams' notable lateral motions during tests of most operating profilers, combined with the insufficiencies of their optical components, generate significant errors of ∼ 1  μ rad rms in the measurements. The solution to nano-radian accuracy for the new generation of surface profilers in this range is to apply a scanning optical head, combined with nontilted reference beam. I describe here my comparison of different scan modes and discuss some test results.« less

  3. Precision Airdrop (Largage de precision)

    DTIC Science & Technology

    2005-12-01

    NAVIGATION TO A PRECISION AIRDROP OVERVIEW RTO-AG-300-V24 2 - 9 the point from various compass headings. As the tests are conducted, the resultant...rate. This approach avoids including a magnetic compass for the heading reference, which has difficulties due to local changes in the magnetic field...Scientifica della Difesa ROYAUME-UNI Via XX Settembre 123 Dstl Knowledge Services ESPAGNE 00187 Roma Information Centre, Building 247 SDG TECEN / DGAM

  4. Robotics in otolaryngology and head and neck surgery: Recommendations for training and credentialing

    PubMed Central

    Gross, Neil D.; Holsinger, F. Christopher; Magnuson, J. Scott; Duvvuri, Umamaheswar; Genden, Eric M.; Ghanem, Tamer AH.; Yaremchuk, Kathleen L.; Goldenberg, David; Miller, Matthew C.; Moore, Eric J.; Morris, Luc GT.; Netterville, James; Weinstein, Gregory S.; Richmon, Jeremy

    2016-01-01

    Training and credentialing for robotic surgery in otolaryngology - head and neck surgery is currently not standardized, but rather relies heavily on industry guidance. This manuscript represents a comprehensive review of this increasingly important topic and outlines clear recommendations to better standardize the practice. The recommendations provided can be used as a reference by individuals and institutions alike, and are expected to evolve over time. PMID:26950771

  5. Carbon dioxide exchange in compact and semi-open sorghum inflorescences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eastin, J.D.; Sullivan, C.Y.

    Carbon dioxide exchange rates were monitored in light and dark in compact and semi-open heads of sorghum (Sorghum bicolor (L.) Moench). Developmental stages ranged from bottom to hard dough in the grain. Highest CO/sub 2/ uptake in both head types occurred at the bloom stage when net uptake rates for semi-open and compact type heads were 3.9 and 1.2 mg CO/sub 2/ g dry wt/sup -1/ hr/sup -1/, respectively. Beginning at the milk stage, a net CO/sub 2/ evolution on the order of 1 to 1.4 mg g dry wt/sup -1/ hr/sup -1/ occurred in compact heads in the light.more » The semi-open head type continued a small net CO/sub 2/ uptake in the light through the milk and soft dough stages. Both head types evolved CO/sub 2/ at hard dough stage. Dark respiration was similar in both head types and decreased from about 4 to 1 mg CO/sub 2/ g dry wt/sup -1/ hr/sup -1/ from bloom to hard dough. 16 references, 1 figure.« less

  6. Frontal and oblique crash tests of HIII 6-year-old child ATD using real-world, observed child passenger postures.

    PubMed

    Bohman, Katarina; Arbogast, Kristy B; Loeb, Helen; Charlton, Judith L; Koppel, Sjaan; Cross, Suzanne L

    2018-02-28

    The aim of this study was to evaluate the consequences of frontal and oblique crashes when positioning a Hybrid III (HIII) 6-year-old child anthropometric test device (ATD) using observed child passenger postures from a naturalistic driving study (NDS). Five positions for booster-seated children aged 4-7 years were selected, including one reference position according to the FMVSS 213 ATD seating protocol and 4 based on real-world observed child passenger postures from an NDS including 2 user positions with forward tilting torso and 2 that combined both forward and lateral inboard tilting of the torso. Seventeen sled tests were conducted in a mid-sized vehicle body at 64 km/h (European New Car Assessment Programme [Euro NCAP] Offset Deformable Barrier [ODB] pulse), in full frontal and oblique (15°) crash directions. The rear-seated HIII 6-year-old child ATD was restrained on a high-back booster seat. In 10 tests, the booster seat was also attached with a top tether. In the oblique tests, the ATD was positioned on the far side. Three camera views and ATD responses (head, neck, and chest) were analyzed. The shoulder belt slipped off the shoulder in all ATD positions in the oblique test configuration. In full frontal tests, the shoulder belt stayed on the shoulder in 3 out of 9 tests. Head acceleration and neck tension were decreased in the forward leaning positions; however, the total head excursion increased up to 210 mm compared to te reference position, due to belt slip-off and initial forward leaning position. These results suggest that real-world child passenger postures may contribute to shoulder belt slip-off and increased head excursion, thus increasing the risk of head injury. Restraint system development needs to include a wider range of sitting postures that children may choose, in addition to the specified postures of ATDs in seating test protocols, to ensure robust performance across diverse use cases. In addition, these tests revealed that the child ATD is limited in its ability to mimic real-world child passenger postures. There is a need to develop child human body models that may offer greater flexibility for these types of crash evaluations.

  7. Head position of helicopter pilots during slalom maneuvers.

    PubMed

    Temme, Leonard A; Still, David L

    2007-01-01

    Pilots typically tilt their heads when executing coordinated banking turns, a phenomenon commonly attributed to the putative opto-kinetic cervical reflex (OKCR). The OKCR is usually described as a reflex, primarily driven by stimuli in the visual periphery, and is important to a pilot's spatial orientation by providing a relatively stabilized horizontal frame of reference. The present paper presents an alternative hypothesis for the observed head tilting seen in pilots. An archived data set, originally collected for other purposes, contained the head turn, pitch, and tilt of 4 helicopter pilots recorded at 10 Hz as the pilots executed 42 slalom maneuvers in an AH Mk 7 Lynx helicopter under visual flight conditions. The analytic method was a correlational analysis of head turn, pitch, and tilt. As expected, pilots routinely tilted their heads during the slaloms in a fashion typically attributed to the OKCR. Correlations among head turn, tilt, and pitch showed that when the helicopter turned left, the head, presumably to look into the turn, turned left and also pitched up and tilted right. Similarly, when the helicopter turned right, the head, presumably to look into the turn, turned right, pitched up, and tilted left. The head tilting usually attributed to a neuromuscular reflex driven by visual stimuli may be a biomechanical consequence of the head posture pilots assume when they simply look where they are going, eliminating the need to postulate the existence of a novel neuromuscular reflex.

  8. Development of the scanning system to detect the concentration of oxy- and deoxy-hemoglobin by tracking the head

    NASA Astrophysics Data System (ADS)

    Ko, Woo Seok; Darwish, Naser; Gratton, Enrico; Kim, Soo Hyun

    2005-04-01

    We measure the concentration of oxy-, deoxy- and total hemoglobin by using the frequency-domain, near-infrared spectroscopy(NIRS) scanner. It is a non-invasive instrument that can provide real-time measurements of the changes in concentration. It can provide a diagnostic tool for the study of the brain in infants and children. However, it is difficult to apply it to the baby's head because of the contact of the probe on the soft baby's head. Therefore, we suggest the NIRS scanning system that can track the baby' head movement and detect NIRS parameters on the same position of the head. This system has three key components. The vision system performs the pattern matching for tracking the head by using the normalized cross correlation method with the target as a cross-line on the head during the diagnostic experiment. We can use the change of the position of the baby's head to re-target the light by the scanning system that uses four laser sources, a wavelength selector, and an x-y scanner. The detector system analyzes the resulting signal from the head using the diffusion model. Therefore, NIRS scanning system can provide a diagnostic tool to measure the changes of the NIRS parameters for the study of the baby's brain.

  9. The head problem. The organizational significance of segmentation in head development.

    PubMed

    Horder, Tim J; Presley, Robert; Slípka, Jaroslav

    2010-01-01

    This review argues for the segmental basis of chordate head organization which, like somite-based segmental organization in the trunk, takes its origin from early mesodermal development. The review builds on, and brings up to date, Goodrich's well-known scheme of head organization. It surveys recent data in support of this scheme and shows how evidence and arguments supposedly in conflict with it can be accommodated. Many of the arguments revolve around matters of methodology; the limitations of older LM, SEM (on which the concept of "somitomeres" is based) and recent molecular evidence (which has sometimes been seen as allocating the central role in head organization to the CNS and the neural crest) are highlighted and shown to explain a number of claims contrary to Goodrich's. We provide (in Part 2) a new, comparative survey of the best available evidence most directly relevant to the Goodrich Bauplan, with a special emphasis on stem chordates. The postotic region has commonly been seen as segmentally organized: the critical issues concern the preotic region. There are many reasons why Goodrich's three preotic segments may become specialized during evolution and why the underlying initial segmental organization may be overridden in later stages during embryonic development; we refer to a number of these. We conclude that the preotic segmental Bauplan is remarkably conserved and most explicitly demonstrated among stem forms, but we also suggest that the concept of the prechordal plate requires careful reexamination. Central to our overall analysis is the importance of the epigenetic nature of embryogenesis; its implications are made clear. Finally we speculate on evolutionary implications for the origin of the head and its specialized features. The review is intended to serve as a resource giving access to references to a wealth of now neglected, older data on anamniote embryology.

  10. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible.

    PubMed

    Hayama, Hironari; Fueki, Kenji; Wadachi, Juro; Wakabayashi, Noriyuki

    2018-03-01

    It remains unclear whether digital impressions obtained using an intraoral scanner are sufficiently accurate for use in fabrication of removable partial dentures. We therefore compared the trueness and precision between conventional and digital impressions in the partially edentulous mandible. Mandibular Kennedy Class I and III models with soft silicone simulated-mucosa placed on the residual edentulous ridge were used. The reference models were converted to standard triangulated language (STL) file format using an extraoral scanner. Digital impressions were obtained using an intraoral scanner with a large or small scanning head, and converted to STL files. For conventional impressions, pressure impressions of the reference models were made and working casts fabricated using modified dental stone; these were converted to STL file format using an extraoral scanner. Conversion to STL file format was performed 5 times for each method. Trueness and precision were evaluated by deviation analysis using three-dimensional image processing software. Digital impressions had superior trueness (54-108μm), but inferior precision (100-121μm) compared to conventional impressions (trueness 122-157μm, precision 52-119μm). The larger intraoral scanning head showed better trueness and precision than the smaller head, and on average required fewer scanned images of digital impressions than the smaller head (p<0.05). On the color map, the deviation distribution tended to differ between the conventional and digital impressions. Digital impressions are partially comparable to conventional impressions in terms of accuracy; the use of a larger scanning head may improve the accuracy for removable partial denture fabrication. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. Frames of reference for gaze saccades evoked during stimulation of lateral intraparietal cortex.

    PubMed

    Constantin, A G; Wang, H; Martinez-Trujillo, J C; Crawford, J D

    2007-08-01

    Previous studies suggest that stimulation of lateral intraparietal cortex (LIP) evokes saccadic eye movements toward eye- or head-fixed goals, whereas most single-unit studies suggest that LIP uses an eye-fixed frame with eye-position modulations. The goal of our study was to determine the reference frame for gaze shifts evoked during LIP stimulation in head-unrestrained monkeys. Two macaques (M1 and M2) were implanted with recording chambers over the right intraparietal sulcus and with search coils for recording three-dimensional eye and head movements. The LIP region was microstimulated using pulse trains of 300 Hz, 100-150 microA, and 200 ms. Eighty-five putative LIP sites in M1 and 194 putative sites in M2 were used in our quantitative analysis throughout this study. Average amplitude of the stimulation-evoked gaze shifts was 8.67 degrees for M1 and 7.97 degrees for M2 with very small head movements. When these gaze-shift trajectories were rotated into three coordinate frames (eye, head, and body), gaze endpoint distribution for all sites was most convergent to a common point when plotted in eye coordinates. Across all sites, the eye-centered model provided a significantly better fit compared with the head, body, or fixed-vector models (where the latter model signifies no modulation of the gaze trajectory as a function of initial gaze position). Moreover, the probability of evoking a gaze shift from any one particular position was modulated by the current gaze direction (independent of saccade direction). These results provide causal evidence that the motor commands from LIP encode gaze command in eye-fixed coordinates but are also subtly modulated by initial gaze position.

  12. Kinematic principles of primate rotational vestibulo-ocular reflex. II. Gravity-dependent modulation of primary eye position

    NASA Technical Reports Server (NTRS)

    Hess, B. J.; Angelaki, D. E.

    1997-01-01

    The kinematic constraints of three-dimensional eye positions were investigated in rhesus monkeys during passive head and body rotations relative to gravity. We studied fast and slow phase components of the vestibulo-ocular reflex (VOR) elicited by constant-velocity yaw rotations and sinusoidal oscillations about an earth-horizontal axis. We found that the spatial orientation of both fast and slow phase eye positions could be described locally by a planar surface with torsional variation of <2.0 +/- 0.4 degrees (displacement planes) that systematically rotated and/or shifted relative to Listing's plane. In supine/prone positions, displacement planes pitched forward/backward; in left/right ear-down positions, displacement planes were parallel shifted along the positive/negative torsional axis. Dynamically changing primary eye positions were computed from displacement planes. Torsional and vertical components of primary eye position modulated as a sinusoidal function of head orientation in space. The torsional component was maximal in ear-down positions and approximately zero in supine/prone orientations. The opposite was observed for the vertical component. Modulation of the horizontal component of primary eye position exhibited a more complex dependence. In contrast to the torsional component, which was relatively independent of rotational speed, modulation of the vertical and horizontal components of primary position depended strongly on the speed of head rotation (i.e., on the frequency of oscillation of the gravity vector component): the faster the head rotated relative to gravity, the larger was the modulation. Corresponding results were obtained when a model based on a sinusoidal dependence of instantaneous displacement planes (and primary eye position) on head orientation relative to gravity was fitted to VOR fast phase positions. When VOR fast phase positions were expressed relative to primary eye position estimated from the model fits, they were confined approximately to a single plane with a small torsional standard deviation ( approximately 1.4-2.6 degrees). This reduced torsional variation was in contrast to the large torsional spread (well >10-15 degrees ) of fast phase positions when expressed relative to Listing's plane. We conclude that primary eye position depends dynamically on head orientation relative to space rather than being fixed to the head. It defines a gravity-dependent coordinate system relative to which the torsional variability of eye positions is minimized even when the head is moved passively and vestibulo-ocular reflexes are evoked. In this general sense, Listing's law is preserved with respect to an otolith-controlled reference system that is defined dynamically by gravity.

  13. Helmet Use and Head Injury in Homer's Iliad.

    PubMed

    Swinney, Christian

    2016-06-01

    Homer's detailed descriptions of head injuries inflicted during the Trojan War are of particular interest to individuals in the medical community. Although studies have examined the prevalence of such injuries, none have examined the preventive measures taken to avoid them. An in-depth review of helmet use in Homer's Iliad was conducted to address this previously unexplored facet of the epic. An English translation of Homer's text was reviewed for all references to helmet use. The number of helmet references in each book was recorded, along with other pertinent details for each reference. There were 87 references to helmets (40 combat, 47 noncombat). The helmet belonged to a Greek warrior in 41 cases (47.1%), a Trojan warrior in 38 cases (43.6%), a divinity in 5 cases (5.7%), and a general group of warriors in 3 cases (3.4%). Helmet use provided protective benefit to Greek warriors at a rate of 30.0% (3 of 10) and Trojan warriors at a rate of 11.1% (2 of 18). This difference was not statistically significant (P = 0.23). The overall combined protective benefit of helmet use in the text was 17.9% (5 of 28). Helmets belonging to 15 specific Greek warriors and 18 specific Trojan warriors were referenced in the text. Helmets belonging to Hector (n = 12) and Achilles (n = 8) were most frequently mentioned. Helmet use and head injury both play a prominent role in Homer's Iliad. Helmets are frequently used in combat settings but with relatively little success. Helmets are also used in various noncombat settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. [Reference values for the vestibulo-ocular reflex response to the head shaking and the bithermal caloric tests].

    PubMed

    Molina, M I; Zapata, C; Palma, M J; López-Escámez, J A

    2006-01-01

    To obtain reference values for the vestibulo-ocular reflex response to the head-shaking nystagmus and the bithermal caloric test in the spanish population. A descriptive study. SET UP: General hospital. One hundred and seven healthy sex and age stratified voluntiers were included. The final sample included 97 individuals over 18 years of age. Spontaneous nystagmus (SN), head-shaking nystagmus (HSN) and caloric induced nystagmus were explored. The eyes movement was recorded by a video-oculographic system. The SN or HSN was considered significant when at least 6 consecutive beats with a slow phase velocity of 2 degrees/sec were detected. The caloric test was performed with water flow at 250mL/20 s at 30 degrees C and 44 degrees C with an interval of 10 minutes between irrigations. The percentage of canal paresis (CP) and directional preponderance (DP) was calculated using maximum slow phase velocity and the Jongkees index formula. Presence of SN, horizontal and vertical SHN, percentage of CP and DP. SN was found in 10,3% individuals (6 women and 4 men). Horizontal HSN was also observed in 9 women and 10 men (19,5%), and vertical HSN in 8 women and 10 men (18,6%). The mean and 95 percentil for CP were 13,10 and 28,60 in women and 11,02 and 27,30 in men. For DP, the mean and 95 percentil were 11,76 and 35,80 in women and 11,58 and 28,65 in men. The 5 percentils for slow phase velocity of nystagmus after each irrigation were 6,30; 5,14; 5,96; 4,02 degrees/s (left ear 44 degrees, right ear 44 degrees, left ear 30 degrees, right ear 30 degrees, respectively) in the group of women; and 5,82; 6,99; 5,67; 4,55 degrees/s in men (with the same irrigation sequence). Results presented should be considered as a population-based norms and may be useful as references for water bithermal test for VOG studies. The SN or HSN could be observed in subjects without vestibular pathology.

  15. Neck forces and moments and head accelerations in side impact.

    PubMed

    Yoganandan, Narayan; Pintar, Frank A; Maiman, Dennis J; Philippens, Mat; Wismans, Jac

    2009-03-01

    Although side-impact sled studies have investigated chest, abdomen, and pelvic injury mechanics, determination of head accelerations and the associated neck forces and moments is very limited. The purpose of the present study was therefore to determine the temporal forces and moments at the upper neck region and head angular accelerations and angular velocities using postmortem human subjects (PMHS). Anthropometric data and X-rays were obtained, and the specimens were positioned upright on a custom-designed seat, rigidly fixed to the platform of the sled. PMHS were seated facing forward with the Frankfort plane horizontal, and legs were stretched parallel to the mid-sagittal plane. The normal curvature and alignment of the dorsal spine were maintained without initial torso rotation. A pyramid-shaped nine-accelerometer package was secured to the parietal-temporal region of the head. The test matrix consisted of groups A and B, representing the fully restrained torso condition, and groups C and D, representing the three-point belt-restrained torso condition. The change in velocity was 12.4 m/s for groups A and C, 17.9 m/s for group B, and 8.7 m/s for group D tests. Two specimens were tested in each group. Injuries were scored based on the Abbreviated Injury Scale. The head mass, center of gravity, and moment of inertia were determined for each specimen. Head accelerations and upper neck forces and moments were determined before head contact. Neck forces and moments and head angular accelerations and angular velocities are presented on a specimen-by-specimen basis. In addition, a summary of peak magnitudes of biomechanical data is provided because of their potential in serving as injury reference values characterizing head-neck biomechanics in side impacts. Though no skull fractures occurred, AIS 0 to 3 neck traumas were dependent on the impact velocity and restraint condition. Because specimen-specific head center of gravity and mass moment of inertia were determined, and a suitable instrumentation system was used for data collection and analysis, head angular accelerations and neck forces and moments determined in the present study can be used with confidence to advance impact biomechanics research. Although the sample size is limited in each group, results from these tests serve as a fundamental data set to validate finite element models and evaluate the performance and biofidelity of federalized and prototype side-impact dummies with a focus on head-neck biomechanics.

  16. Supervisory Rotation: Impact on an Academic Library Reference Staff.

    ERIC Educational Resources Information Center

    Perdue, Bob; Piotrowski, Chris

    The results of a managerial rotation program in a medium-sized academic library reference department are presented. After meeting certain minimal eligibility requirements, librarians in this department take turns on a 2-year cycle serving as head of the department. This case study is used as a model to assess both the advantages and disadvantages…

  17. Economic burden of non-cervical cancers attributable to human papillomavirus: a European scoping review.

    PubMed

    Préaud, Emmanuelle; Largeron, Nathalie

    2013-01-01

    Human papillomavirus (HPV) has an important role in the aetiology of a range of diseases, including cervical, other anogenital, and head and neck cancers, genital warts and recurrent respiratory papillomatosis. This literature review was conducted to identify the available cost data for non-cervical HPV-related cancers (anal, penile, vulvar, vaginal, head and neck) in Europe and to inform discussion of methodological challenges for future economic research. The literature search was conducted using Medline and key words to identify papers published in English or French between 1 January 2000 and 31 December 2011. Abstracts of major conferences were searched to identify relevant information. Structured methods were used to select references that focused on overall disease management for inclusion in the review. A total of 21 references from seven countries (Denmark, France, Germany, Greece, The Netherlands, Portugal, and the UK) were selected, including 11 references relating to head and neck cancers, five to anogenital cancers, and five to more than one HPV-related disease. Non-cervical cancers accounted for a substantial proportion of the economic burden of HPV-related cancers, and this burden was mainly driven by men (∼70%). A wide range of costs were reported for each disease, particularly head and neck cancers, predominantly due to disease complexity and variation in study design. The main limitation of this study was in the search strategy, which was constrained by the key words, the database searched, and the restriction on language (English/French). Non-cervical cancers attributable to HPV impose a substantial economic burden in Europe, and the burden is greater in men than in women. This review provides useful information for future health-economic studies assessing the impact of HPV vaccination on all HPV-related diseases.

  18. Best-estimate coupled RELAP/CONTAIN analysis of inadvertent BWR ADS valve opening transient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feltus, M.A.; Muftuoglu, A.K.

    1993-01-01

    Noncondensible gases may become dissolved in boiling water reactor (BWR) water-level instrumentation during normal operations. Any dissolved noncondensible gases inside these water columns may come out of solution during rapid depressurization events and displace water from the reference leg piping, resulting in a false high level. Significant errors in water-level indication are not expected to occur until the reactor pressure vessel (RPV) pressure has dropped below [approximately]450 psig. These water level errors may cause a delay or failure in emergency core cooling system (ECCS) actuation. The RPV water level is monitored using the pressure of a water column having amore » varying height (reactor water level) that is compared to the pressure of a water column maintained at a constant height (reference level). The reference legs have small-diameter pipes with varying lengths that provide a constant head of water and are located outside the drywell. The amount of noncondensible gases dissolved in each reference leg is very dependent on the amount of leakage from the reference leg and its geometry and interaction of the reactor coolant system with the containment, i.e., torus or suppression pool, and reactor building. If a rapid depressurization causes an erroneously high water level, preventing automatic ECCS actuation, it becomes important to determine if there would be other adequate indications for operator response. In the postulated inadvertent opening of all seven automatic depressurization system (ADS) valves, the ECCS signal on high drywell pressure would be circumvented because the ADS valves discharge directly into the suppression pool. A best-estimate analysis of such an inadvertent opening of all ADS valves would have to consider the thermal-hydraulic coupling between the pool, drywell, reactor building, and RPV.« less

  19. Vomiting--is this a good indication for CT head scans in patients with minor head injury?

    PubMed

    Bainbridge, J; Khirwadkar, H; Hourihan, M D

    2012-02-01

    The National Institute for Health and Clinical Excellence head injury guidelines advise CT imaging within 1 h if there is more than one episode of vomiting post-head injury in adults and three or more episodes in children. Since the guideline publication, studies have found that, following head injury, vomiting alone is associated with an abnormal CT head scan in 13-45% of cases. CT head scan requests referred from the emergency department between 1 May 2009 and 30 April 2010 were retrospectively reviewed. Patients with vomiting as the sole indication for an "immediate" CT head scan performed within 1 h were included in the study. Reports produced by experienced neuroradiologists were reviewed and the detection of significant head injury was noted. There were 1264 CT head scans performed during our study period. 151 (124 adults, 27 children) were indicated owing to vomiting following head injury. 5 of the 124 adult scans and 1 of the 27 paediatric scans showed an abnormal finding, giving positive predictive values (PPV) of 4% and 3.7%, respectively. None of these patients required either acute or delayed neurosurgical intervention. In our experience, vomiting alone has a PPV of 4% for significant head injury in adults. However, none of these injuries were serious enough to warrant acute or delayed intervention. Given these findings, vomiting following head injury is a reasonable indication for a CT head scan; however, as none of the patients required acute intervention, we suggest that these scans do not usually need to be performed within 1 h of request.

  20. Hydro pumped storage, international experience: An overview of ASCE task committee report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarechian, A.H.; Rummel, G.

    1995-12-31

    This paper presents an overview of a report that is being prepared by ASCE Task Committee on Pumped Storage, International Experience. The reader is referred to the committee report that will be available in 1996. Many pumped storage projects in Europe, but particularly in Japan are becoming an indispensable resource in management of loads and resources on the electrical system. They serve to enhance reliability of the system and to provide for efficient utilization of thermal resources. Pumped storage is increasingly being used as a system management tool. To serve such purposes and to function in this key role, pumpedmore » storage projects are designed for very fast loading and unloading, for very fast mode reversals from pumping to generating and visa versa, for synchronous generation, and more importantly for load ramping during the pumping mode. This is achieved by use of variable-speed pump turbine units. The use of variable-speed units has proven so successful in Japan that many older projects are retrofitted with this new feature. Other interesting equipment applications are discussed including utilization of multi-stage unregulated pump turbines for very high heads (up to 1,250 m), and continued extension of the experience for high head reversible Francis unit, currently in excess of 750 m.« less

  1. Multi-Head Very High Power Strobe System For Motion Picture Special Effects

    NASA Astrophysics Data System (ADS)

    Lovoi, P. A.; Fink, Michael L.

    1983-10-01

    A very large camera synchronizable strobe system has been developed for motion picture special effects. This system, the largest ever built, was delivered to MGM/UA to be used in the movie "War Games". The system consists of 12 individual strobe heads and a power supply distribution system. Each strobe head operates independently and may be flashed up to 24 times per second under computer control. An energy of 480 Joules per flash is used in six strobe heads and 240 Joules per flash in the remaining six strobe heads. The beam pattern is rectangular with a FWHM of 60° x 48°.

  2. Robotics in otolaryngology and head and neck surgery: Recommendations for training and credentialing: A report of the 2015 AHNS education committee, AAO-HNS robotic task force and AAO-HNS sleep disorders committee.

    PubMed

    Gross, Neil D; Holsinger, F Christopher; Magnuson, J Scott; Duvvuri, Umamaheswar; Genden, Eric M; Ghanem, Tamer Ah; Yaremchuk, Kathleen L; Goldenberg, David; Miller, Matthew C; Moore, Eric J; Morris, Luc Gt; Netterville, James; Weinstein, Gregory S; Richmon, Jeremy

    2016-04-01

    Training and credentialing for robotic surgery in otolaryngology - head and neck surgery is currently not standardized, but rather relies heavily on industry guidance. This manuscript represents a comprehensive review of this increasingly important topic and outlines clear recommendations to better standardize the practice. The recommendations provided can be used as a reference by individuals and institutions alike, and are expected to evolve over time. © 2016 Wiley Periodicals, Inc. Head Neck 38: E151-E158. © 2016 Wiley Periodicals, Inc.

  3. Recent Advances in Image-Guided Radiotherapy for Head and Neck Carcinoma

    PubMed Central

    Nath, Sameer K.; Simpson, Daniel R.; Rose, Brent S.; Sandhu, Ajay P.

    2009-01-01

    Radiotherapy has a well-established role in the management of head and neck cancers. Over the past decade, a variety of new imaging modalities have been incorporated into the radiotherapy planning and delivery process. These technologies are collectively referred to as image-guided radiotherapy and may lead to significant gains in tumor control and radiation side effect profiles. In the following review, these techniques as they are applied to head and neck cancer patients are described, and clinical studies analyzing their use in target delineation, patient positioning, and adaptive radiotherapy are highlighted. Finally, we conclude with a brief discussion of potential areas of further radiotherapy advancement. PMID:19644564

  4. A transformation method for deriving from a photograph, position and heading of a vehicle in a plane

    NASA Technical Reports Server (NTRS)

    Sleeper, R. K.; Smith, E. G.

    1976-01-01

    Equations have been derived that transform perspectively viewed planar surface coordinates, as seen in a photograph, into coordinates of the original plane surface. These transformation equations are developed in terms of nine geometric variables that define the photographic setup and are redefined in terms of eight parameters. The parameters are then treated as independent quantities that fully characterize the transformation and are expressed directly in terms of the four corner coordinates of a reference rectangle in the object plane and their coordinates as seen in a photograph. Vehicle position is determined by transforming the perspectively viewed coordinate position of a representative vehicle target into runway coordinates. Vehicle heading is determined from the runway coordinates of two vehicle target points. When the targets are elevated above the plane of the reference grid, the computation of the heading angle is unaffected; however, the computation of the target position may require adjustment of two parameters. Methods are given for adjusting the parameters for elevation and an example is included for both nonelevated and elevated target conditions.

  5. Perceived Surface Slant Is Systematically Biased in the Actively-Generated Optic Flow

    PubMed Central

    Fantoni, Carlo; Caudek, Corrado; Domini, Fulvio

    2012-01-01

    Humans make systematic errors in the 3D interpretation of the optic flow in both passive and active vision. These systematic distortions can be predicted by a biologically-inspired model which disregards self-motion information resulting from head movements (Caudek, Fantoni, & Domini 2011). Here, we tested two predictions of this model: (1) A plane that is stationary in an earth-fixed reference frame will be perceived as changing its slant if the movement of the observer's head causes a variation of the optic flow; (2) a surface that rotates in an earth-fixed reference frame will be perceived to be stationary, if the surface rotation is appropriately yoked to the head movement so as to generate a variation of the surface slant but not of the optic flow. Both predictions were corroborated by two experiments in which observers judged the perceived slant of a random-dot planar surface during egomotion. We found qualitatively similar biases for monocular and binocular viewing of the simulated surfaces, although, in principle, the simultaneous presence of disparity and motion cues allows for a veridical recovery of surface slant. PMID:22479473

  6. Analysis of linear head accelerations from collegiate football impacts.

    PubMed

    Brolinson, P Gunnar; Manoogian, Sarah; McNeely, David; Goforth, Mike; Greenwald, Richard; Duma, Stefan

    2006-02-01

    Sports-related concussions result in 300,000 brain injuries in the United States each year. We conducted a study utilizing an in-helmet system that measures and records linear head accelerations to analyze head impacts in collegiate football. The Head Impact Telemetry (HIT) System is an in-helmet system with six spring-mounted accelerometers and an antenna that transmits data via radio frequency to a sideline receiver and laptop computer system. A total of 11,604 head impacts were recorded from the Virginia Tech football team throughout the 2003 and 2004 football seasons during 22 games and 62 practices from a total of 52 players. Although the incidence of injury data are limited, this study presents an extremely large data set from human head impacts that provides valuable insight into the lower limits of head acceleration that cause mild traumatic brain injuries.

  7. Analysis of a flare-director concept for an externally blown flap STOL aircraft

    NASA Technical Reports Server (NTRS)

    Middleton, D. B.

    1974-01-01

    A flare-director concept involving a thrust-required flare-guidance equation was developed and tested on a moving-base simulator. The equation gives a signal to command thrust as a linear function of the errors between the variables thrust, altitude, and altitude rate and corresponding values on a desired reference flare trajectory. During the simulator landing tests this signal drove either the horizontal command bar of the aircraft's flight director or a thrust-command dot on a head-up virtual-image display of a flare director. It was also used as the input to a simple autoflare system. An externally blown flap STOL (short take-off and landing) aircraft (with considerable stability and control augmentation) was modeled for the landing tests. The pilots considered the flare director a valuable guide for executing a proper flare-thrust program under instrument-landing conditions, but were reluctant to make any use of the head-up display when they were performing the landings visually.

  8. Quality of life of head and neck cancer patients in urban and regional areas: An Australian perspective.

    PubMed

    Pateman, Kelsey A; Cockburn, Nicole L; Batstone, Martin D; Ford, Pauline J

    2018-06-01

    Head and neck cancer treatment affects quality of life. There are differences in quality of life outcomes and perceived supportive care needs between cancer patients living in metropolitan and regional-remote areas. This study investigated quality of life over the first 6 months following head and neck cancer diagnosis and observed differences in quality of life by geographical location. Prospective observational study. Tertiary hospital in Brisbane, Australia. Newly diagnosed patients who were referred for the diagnosis, and/or treatment of head and neck cancer. Quality of life was measured by the University of Washington Quality of Life Survey, version 4 (UW-QoL). Participants completed the UW-QoL questionnaire prior to starting treatment, 1 month and 6 months post treatment. Metropolitan and regional or remote status was classified according to the Australian Standard Geographic Classification-Remoteness Area system. Ninety-five participants were included at baseline; 49 and 41 participants completed the 1-month and 6-month follow-ups, respectively. Scores in most UW-QoL domains decreased between baseline and 1 month post treatment and increased towards pre-treatment scores at the 6-month follow-up (except for anxiety and saliva). Pain at baseline was significantly worse in the regional-remote participants compared with metropolitan participants. No other statistically significant differences in UW-QoL score by geographical location were observed. The findings generally did not support significant differences in quality of life outcome between metropolitan and regional-remote head and neck cancer patients. The difference in pain experience between metropolitan and regional-remote groups requires further investigation. © 2018 National Rural Health Alliance Ltd.

  9. Research study on neck injury lessening with active head restraint using human body FE model.

    PubMed

    Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji

    2008-12-01

    The objective of this study is to examine the effectiveness of the active head restraint system in reducing neck injury risk of car occupants in low-speed rear impacts. A human body FE model "THUMS" was used to simulate head and neck kinematics of the occupant and to evaluate loading to the neck. Joint capsule strain was calculated to predict neck injury risk as well as NIC. The validity of the model was confirmed comparing its mechanical responses to those in human subjects in the literatures. Seat FE models were also prepared representing one with a fixed head restraint and the other one with an active head restraint system. The active head restraint system was designed to move the head restraint forward and upward when the lower unit was lower unit was loaded by the pelvis. Rear impact simulations were performed assuming a triangular acceleration pulse at a delta-V of 25 km/h. The model reproduced similar head and neck motions to those measured in the human volunteer test, except for active muscular responses. The calculated joint capsule strain also showed a good match with those of PMHS tests in the literature. A rear-impact simulation was conducted using the model with the fixed head restraint. The result revealed that NIC was strongly correlated with the relative acceleration between the head and the torso and that its maximum peak appeared when the head contacted the head restraint. It was also found that joint capsule strain grew in later timing synchronizing with the relative displacement. Another simulation with the active head restraint system showed that both NIC and joint capsule strain were lowered owing to the forward and upward motion of the head restraint. A close investigation of the vertebral motion indicated that the active head restraint reduced the magnitude of shear deformation in the facet joint, which contributed to the strain growth in the fixed head restraint case. Rear-impact simulations were conducted using a human body FE model, THUMS, representing an average-size male occupant. The cervical system including the facet joint capsules was incorporated to the model. The validity of the model was examined comparing its mechanical responses to those in the literature such as the whole body motion of the volunteer subject and the vertebral motion in the PMHS tests. Rear-impact simulations were conducted using the validated THUMS model and two prototype seat models; one had a fixed head restraint and the other one was equipped with an active head restraint system. The active head restraint system works moving the head restraint forward and upward when the lower unit is loaded by the pelvis. The head and neck kinematics and responses were analyzed from the simulation results. The force and acceleration rose at the pelvis first, followed by T1 and the head. The early timing of force rise and its magnitude indicated that the pelvis force was a good trigger for the active head restraint system. The results showed that the head was supported earlier in a case with the active head restraint system, and both NIC and joint capsule strain were lowered. The study also analyzed the mechanism of strain growth in the joint capsules. Relatively greater strain was observed in the direction of the facet joint surface, which was around 45 degrees inclined to the spinal column. The forward and upward motion of the active head restraint were aligned with the direction of the joint deformation and contributed to lower strain in the joint capsules. The results indicated that the active head restraint could help reduce the neck injury risk not only by supporting the head at an early timing but also through its trajectory stopping the joint deformation.

  10. Ascent trajectory dispersion analysis for WTR heads-up space shuttle trajectory

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The results of a Space Transportation System ascent trajectory dispersion analysis are discussed. The purpose is to provide critical trajectory parameter values for assessing the Space Shuttle in a heads-up configuration launched from the Western Test Range (STR). This analysis was conducted using a trajectory profile based on a launch from the WTR in December. The analysis consisted of the following steps: (1) nominal trajectories were simulated under the conditions as specified by baseline reference mission guidelines; (2) dispersion trajectories were simulated using predetermined parametric variations; (3) requirements for a system-related composite trajectory were determined by a root-sum-square (RSS) analysis of the positive deviations between values of the aerodynamic heating indicator (AHI) generated by the dispersion and nominal trajectories; (4) using the RSS assessment as a guideline, the system related composite trajectory was simulated by combinations of dispersion parameters which represented major contributors; (5) an assessment of environmental perturbations via a RSS analysis was made by the combination of plus or minus 2 sigma atmospheric density variation and 95% directional design wind dispersions; (6) maximum aerodynamic heating trajectories were simulated by variation of dispersion parameters which would emulate the summation of the system-related RSS and environmental RSS values of AHI. The maximum aerodynamic heating trajectories were simulated consistent with the directional winds used in the environmental analysis.

  11. Development of the head and trunk mesoderm in the dogfish, Scyliorhinus torazame: II. Comparison of gene expression between the head mesoderm and somites with reference to the origin of the vertebrate head.

    PubMed

    Adachi, Noritaka; Takechi, Masaki; Hirai, Tamami; Kuratani, Shigeru

    2012-01-01

    The vertebrate mesoderm differs distinctly between the head and trunk, and the evolutionary origin of the head mesoderm remains enigmatic. Although the presence of somite-like segmentation in the head mesoderm of model animals is generally denied at molecular developmental levels, the appearance of head cavities in elasmobranch embryos has not been explained, and the possibility that they may represent vestigial head somites once present in an amphioxus-like ancestor has not been ruled out entirely. To examine whether the head cavities in the shark embryo exhibit any molecular signatures reminiscent of trunk somites, we isolated several developmentally key genes, including Pax1, Pax3, Pax7, Pax9, Myf5, Sonic hedgehog, and Patched2, which are involved in myogenic and chondrogenic differentiation in somites, and Pitx2, Tbx1, and Engrailed2, which are related to the patterning of the head mesoderm, from an elasmobranch species, Scyliorhinus torazame. Observation of the expression patterns of these genes revealed that most were expressed in patterns that resembled those found in amniote embryos. In addition, the head cavities did not exhibit an overt similarity to somites; that is, the similarity was no greater than that of the unsegmented head mesoderm in other vertebrates. Moreover, the shark head mesoderm showed an amniote-like somatic/visceral distinction according to the expression of Pitx2, Tbx1, and Engrailed2. We conclude that the head cavities do not represent a manifestation of ancestral head somites; rather, they are more likely to represent a derived trait obtained in the lineage of gnathostomes. © 2012 Wiley Periodicals, Inc.

  12. A kinematic model for 3-D head-free gaze-shifts

    PubMed Central

    Daemi, Mehdi; Crawford, J. Douglas

    2015-01-01

    Rotations of the line of sight are mainly implemented by coordinated motion of the eyes and head. Here, we propose a model for the kinematics of three-dimensional (3-D) head-unrestrained gaze-shifts. The model was designed to account for major principles in the known behavior, such as gaze accuracy, spatiotemporal coordination of saccades with vestibulo-ocular reflex (VOR), relative eye and head contributions, the non-commutativity of rotations, and Listing's and Fick constraints for the eyes and head, respectively. The internal design of the model was inspired by known and hypothesized elements of gaze control physiology. Inputs included retinocentric location of the visual target and internal representations of initial 3-D eye and head orientation, whereas outputs were 3-D displacements of eye relative to the head and head relative to shoulder. Internal transformations decomposed the 2-D gaze command into 3-D eye and head commands with the use of three coordinated circuits: (1) a saccade generator, (2) a head rotation generator, (3) a VOR predictor. Simulations illustrate that the model can implement: (1) the correct 3-D reference frame transformations to generate accurate gaze shifts (despite variability in other parameters), (2) the experimentally verified constraints on static eye and head orientations during fixation, and (3) the experimentally observed 3-D trajectories of eye and head motion during gaze-shifts. We then use this model to simulate how 2-D eye-head coordination strategies interact with 3-D constraints to influence 3-D orientations of the eye-in-space, and the implications of this for spatial vision. PMID:26113816

  13. Going Below Minimums: The Efficacy of Display Enhanced/Synthetic Vision Fusion for Go-Around Decisions during Non-Normal Operations

    NASA Technical Reports Server (NTRS)

    Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.

    2007-01-01

    The use of enhanced vision systems in civil aircraft is projected to increase rapidly as the Federal Aviation Administration recently changed the aircraft operating rules under Part 91, revising the flight visibility requirements for conducting approach and landing operations. Operators conducting straight-in instrument approach procedures may now operate below the published approach minimums when using an approved enhanced flight vision system that shows the required visual references on the pilot's Head-Up Display. An experiment was conducted to evaluate the complementary use of synthetic vision systems and enhanced vision system technologies, focusing on new techniques for integration and/or fusion of synthetic and enhanced vision technologies and crew resource management while operating under these newly adopted rules. Experimental results specific to flight crew response to non-normal events using the fused synthetic/enhanced vision system are presented.

  14. HPAC 96/97 Info-dex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-06-01

    HPAC Info-dex is designed to help in seven different ways. It contains seven information banks that will help find the answers needed to solve a wide variety of mechanical systems problems. Over 1,500 manufacturers of products for mechanical systems are listed alphabetically, along with their complete addresses and telephone numbers. Products for mechanical systems are listed in more than 1,200 categories, and under each heading are the names of the manufacturers supplying that product. Cross references make it easy to find the products. More than 3,000 product trade names are listed alphabetically, and the manufacturer of each is identified. Anmore » index to the 1995 volume of Heating/Piping/Air Conditioning is arranged by areas of interest, title, and author to help find articles that will provide the latest in design, installation, operation, and maintenance practice. A section lists more than 200 engineering societies, trade associations, and government organizations that have established performance standards for mechanical systems and components. Manufacturers` product information provides a ready reference of detailed product information from manufacturers of mechanical systems components. The names, complete addresses, and telephone numbers of all advertisers in HPAC Info-dex are listed along with the page numbers on which their products appear and the reader service numbers assigned to them.« less

  15. [Abnormal head turn in a patient with Brown's syndrome].

    PubMed

    van Waveren, M; Krzizok, T; Besch, D

    2008-08-01

    We report on an eight-year-old boy, who was presented in our clinic because of head turn. The cause of the tortecollis (ocular or general) in this case was and still cannot be explained. Only by applying extensive prism adaptation tests it was possible to prove the ocular character of the head turn. An eight-year-old boy with Brown's syndrome was referred to us because of a head tilt to the left side. Six months previously surgery on the M. obl. superior of the right eye was performed in another clinic. No improvement of the head tilt could be observed after the operation. In addition, an exotropia became decompensated. Under a 3-day occlusion of one eye, no change of the head turn and the squint could be measured. No other cause of the head turn could be found by an orthopaedist and a paediatrist. Under a prism of 20 cm/m basis in and 10 cm/m basis against the positive vertical deviation, the head tilt decreased, so that we decided to do a second surgery. The head tilting had not resumed at one year after the surgery. Although the initial diagnostic findings ruled out an ocular cause, it was possible to lessen the head tilting with the aid of the prism adaptation test. This case study emphasises the usefulness of a prism adaptation test of several days duration in order to validate an ocular cause of head turn and to determine an adequate indication for surgery.

  16. Energy management of three-dimensional minimum-time intercept. [for aircraft flight optimization

    NASA Technical Reports Server (NTRS)

    Kelley, H. J.; Cliff, E. M.; Visser, H. G.

    1985-01-01

    A real-time computer algorithm to control and optimize aircraft flight profiles is described and applied to a three-dimensional minimum-time intercept mission. The proposed scheme has roots in two well known techniques: singular perturbations and neighboring-optimal guidance. Use of singular-perturbation ideas is made in terms of the assumed trajectory-family structure. A heading/energy family of prestored point-mass-model state-Euler solutions is used as the baseline in this scheme. The next step is to generate a near-optimal guidance law that will transfer the aircraft to the vicinity of this reference family. The control commands fed to the autopilot (bank angle and load factor) consist of the reference controls plus correction terms which are linear combinations of the altitude and path-angle deviations from reference values, weighted by a set of precalculated gains. In this respect the proposed scheme resembles neighboring-optimal guidance. However, in contrast to the neighboring-optimal guidance scheme, the reference control and state variables as well as the feedback gains are stored as functions of energy and heading in the present approach. Some numerical results comparing open-loop optimal and approximate feedback solutions are presented.

  17. Optimal Perioperative Care in Major Head and Neck Cancer Surgery With Free Flap Reconstruction: A Consensus Review and Recommendations From the Enhanced Recovery After Surgery Society.

    PubMed

    Dort, Joseph C; Farwell, D Gregory; Findlay, Merran; Huber, Gerhard F; Kerr, Paul; Shea-Budgell, Melissa A; Simon, Christian; Uppington, Jeffrey; Zygun, David; Ljungqvist, Olle; Harris, Jeffrey

    2017-03-01

    Head and neck cancers often require complex, labor-intensive surgeries, especially when free flap reconstruction is required. Enhanced recovery is important in this patient population but evidence-based protocols on perioperative care for this population are lacking. To provide a consensus-based protocol for optimal perioperative care of patients undergoing head and neck cancer surgery with free flap reconstruction. Following endorsement by the Enhanced Recovery After Surgery (ERAS) Society to develop this protocol, a systematic review was conducted for each topic. The PubMed and Cochrane databases were initially searched to identify relevant publications on head and neck cancer surgery from 1965 through April 2015. Consistent key words for each topic included "head and neck surgery," "pharyngectomy," "laryngectomy," "laryngopharyngectomy," "neck dissection," "parotid lymphadenectomy," "thyroidectomy," "oral cavity resection," "glossectomy," and "head and neck." The final selection of literature included meta-analyses and systematic reviews as well as randomized controlled trials where available. In the absence of high-level data, case series and nonrandomized studies in head and neck cancer surgery patients or randomized controlled trials and systematic reviews in non-head and neck cancer surgery patients, were considered. An international panel of experts in major head and neck cancer surgery and enhanced recovery after surgery reviewed and assessed the literature for quality and developed recommendations for each topic based on the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) system. All recommendations were graded following a consensus discussion among the expert panel. The literature search, including a hand search of reference lists, identified 215 relevant publications that were considered to be the best evidence for the topic areas. A total of 17 topic areas were identified for inclusion in the protocol for the perioperative care of patients undergoing major head and neck cancer surgery with free flap reconstruction. Best practice includes several elements of perioperative care. Among these elements are the provision of preoperative carbohydrate treatment, pharmacologic thromboprophylaxis, perioperative antibiotics in clean-contaminated procedures, corticosteroid and antiemetic medications, short acting anxiolytics, goal-directed fluid management, opioid-sparing multimodal analgesia, frequent flap monitoring, early mobilization, and the avoidance of preoperative fasting. The evidence base for specific perioperative care elements in head and neck cancer surgery is variable and in many cases information from different surgerical procedures form the basis for these recommendations. Clinical evaluation of these recommendations is a logical next step and further research in this patient population is warranted.

  18. Laser scanning measurements on trees for logging harvesting operations.

    PubMed

    Zheng, Yili; Liu, Jinhao; Wang, Dian; Yang, Ruixi

    2012-01-01

    Logging harvesters represent a set of high-performance modern forestry machinery, which can finish a series of continuous operations such as felling, delimbing, peeling, bucking and so forth with human intervention. It is found by experiment that during the process of the alignment of the harvesting head to capture the trunk, the operator needs a lot of observation, judgment and repeated operations, which lead to the time and fuel losses. In order to improve the operation efficiency and reduce the operating costs, the point clouds for standing trees are collected with a low-cost 2D laser scanner. A cluster extracting algorithm and filtering algorithm are used to classify each trunk from the point cloud. On the assumption that every cross section of the target trunk is approximate a standard circle and combining the information of an Attitude and Heading Reference System, the radii and center locations of the trunks in the scanning range are calculated by the Fletcher-Reeves conjugate gradient algorithm. The method is validated through experiments in an aspen forest, and the optimized calculation time consumption is compared with the previous work of other researchers. Moreover, the implementation of the calculation result for automotive capturing trunks by the harvesting head during the logging operation is discussed in particular.

  19. Life test results of OLED-XL long-life devices for use in active matrix organic light emitting diode (AMOLED) displays for head mounted applications

    NASA Astrophysics Data System (ADS)

    Fellowes, David A.; Wood, Michael V.; Hastings, Arthur R., Jr.; Ghosh, Amalkumar P.; Prache, Olivier

    2007-04-01

    eMagin Corporation has recently developed long-life OLED-XL devices for use in their AMOLED microdisplays for head-worn applications. AMOLED displays have been known to exhibit high levels of performance with regards to contrast, response time, uniformity, and viewing angle, but a lifetime improvement has been perceived to be essential for broadening the applications of OLED's in the military and in the commercial market. The new OLED-XL devices gave the promise of improvements in usable lifetime over 6X what the standard full color, white, and green devices could provide. The US Army's RDECOM CERDEC NVESD performed life tests on several standard and OLED-XL panels from eMagin under a Cooperative Research and Development Agreement (CRADA). Displays were tested at room temperature, utilizing eMagin's Design Reference Kit driver, allowing computer controlled optimization, brightness adjustment, and manual temperature compensation. The OLED Usable Lifetime Model, developed under a previous NVESD/eMagin SPIE paper presented at DSS 2005, has been adjusted based on the findings of these tests. The result is a better understanding of the applicability of AMOLEDs in military and commercial head mounted systems: where good fits are made, and where further development might be needed.

  20. Analysis on Sealing Reliability of Bolted Joint Ball Head Component of Satellite Propulsion System

    NASA Astrophysics Data System (ADS)

    Guo, Tao; Fan, Yougao; Gao, Feng; Gu, Shixin; Wang, Wei

    2018-01-01

    Propulsion system is one of the important subsystems of satellite, and its performance directly affects the service life, attitude control and reliability of the satellite. The Paper analyzes the sealing principle of bolted joint ball head component of satellite propulsion system and discuss from the compatibility of hydrazine anhydrous and bolted joint ball head component, influence of ground environment on the sealing performance of bolted joint ball heads, and material failure caused by environment, showing that the sealing reliability of bolted joint ball head component is good and the influence of above three aspects on sealing of bolted joint ball head component can be ignored.

  1. A Robust H ∞ Controller for an UAV Flight Control System.

    PubMed

    López, J; Dormido, R; Dormido, S; Gómez, J P

    2015-01-01

    The objective of this paper is the implementation and validation of a robust H ∞ controller for an UAV to track all types of manoeuvres in the presence of noisy environment. A robust inner-outer loop strategy is implemented. To design the H ∞ robust controller in the inner loop, H ∞ control methodology is used. The two controllers that conform the outer loop are designed using the H ∞ Loop Shaping technique. The reference vector used in the control architecture formed by vertical velocity, true airspeed, and heading angle, suggests a nontraditional way to pilot the aircraft. The simulation results show that the proposed control scheme works well despite the presence of noise and uncertainties, so the control system satisfies the requirements.

  2. Cervical vertebral anomalies in patients with anomalies of the head and neck.

    PubMed

    Manaligod, J M; Bauman, N M; Menezes, A H; Smith, R J

    1999-10-01

    Congenital head and neck anomalies can occur in association with vertebral anomalies, particularly of the cervical vertebrae. While the former are easily recognized, especially when part of a syndrome, the latter are often occult, thereby delaying their diagnosis. The presence of vertebral anomalies must be considered in pediatric patients with head and neck abnormalities to expedite management of select cases and to prevent neurologic injury. We present our experience with 5 pediatric patients who were referred to the Department of Otolaryngology-Head and Neck Surgery at the University of Iowa with a variety of syndromic anomalies of the head and neck. Each patient was subsequently also found to have a vertebral anomaly. The relevant embryogenesis of the anomalous structures is discussed, with highlighting of potential causes such as teratogenic agents and events and germ-line mutations. A review of syndromes having both head and neck and vertebral anomalies is presented to heighten awareness of otolaryngologists evaluating children with syndromic disorders. Finally, the findings on radiographic imaging studies, particularly computed tomography, are discussed to facilitate the prompt diagnosis of vertebral anomalies.

  3. Buildup of spatial information over time and across eye-movements.

    PubMed

    Zimmermann, Eckart; Morrone, M Concetta; Burr, David C

    2014-12-15

    To interact rapidly and effectively with our environment, our brain needs access to a neural representation of the spatial layout of the external world. However, the construction of such a map poses major challenges, as the images on our retinae depend on where the eyes are looking, and shift each time we move our eyes, head and body to explore the world. Research from many laboratories including our own suggests that the visual system does compute spatial maps that are anchored to real-world coordinates. However, the construction of these maps takes time (up to 500ms) and also attentional resources. We discuss research investigating how retinotopic reference frames are transformed into spatiotopic reference-frames, and how this transformation takes time to complete. These results have implications for theories about visual space coordinates and particularly for the current debate about the existence of spatiotopic representations. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Otolaryngology and ophthalmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanafee, W.N.

    A literature review with 227 references of the diagnostic use of computerized tomography for head and neck problems is presented. The anatomy, congenital malformations, infectious diseases, and nioplasms of the auditory organs, paranasal sinuses, pharynx, larynx and salivary glands are examined in detail. A major impetus to the use of computerized tomography has been the realization by the health care industry that CT scanning offers details of tumors in the head and neck area that are not available by other modalities. (KRM)

  5. High resolution, MRI-based, segmented, computerized head phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zubal, I.G.; Harrell, C.R.; Smith, E.O.

    1999-01-01

    The authors have created a high-resolution software phantom of the human brain which is applicable to voxel-based radiation transport calculations yielding nuclear medicine simulated images and/or internal dose estimates. A software head phantom was created from 124 transverse MRI images of a healthy normal individual. The transverse T2 slices, recorded in a 256x256 matrix from a GE Signa 2 scanner, have isotropic voxel dimensions of 1.5 mm and were manually segmented by the clinical staff. Each voxel of the phantom contains one of 62 index numbers designating anatomical, neurological, and taxonomical structures. The result is stored as a 256x256x128 bytemore » array. Internal volumes compare favorably to those described in the ICRP Reference Man. The computerized array represents a high resolution model of a typical human brain and serves as a voxel-based anthropomorphic head phantom suitable for computer-based modeling and simulation calculations. It offers an improved realism over previous mathematically described software brain phantoms, and creates a reference standard for comparing results of newly emerging voxel-based computations. Such voxel-based computations lead the way to developing diagnostic and dosimetry calculations which can utilize patient-specific diagnostic images. However, such individualized approaches lack fast, automatic segmentation schemes for routine use; therefore, the high resolution, typical head geometry gives the most realistic patient model currently available.« less

  6. Pediculus humanus capitis (head lice) and Pediculus humanus humanus (body lice): response to laboratory temperature and humidity and susceptibility to monoterpenoids.

    PubMed

    Gallardo, A; Mougabure Cueto, G; Picollo, M I

    2009-07-01

    Human pediculosis is produced by Pediculus humanus humanus (Linnaeus 1758) and Pediculus humanus capitis (De Geer 1767). Laboratory-reared body lice, susceptible to insecticides, were used as reference in toxicological studies on head lice. In this work, we evaluated the survival of both subspecies at different temperatures and relative humidities and we propose the optimal conditions for comparative bioassays. Moreover, we used these conditions to test the activity of three monoterpenoids against both lice. The results showed differential response to changes in temperature and humidity between both organisms. The survival of body lice ranged between 83% and 100% and was not affected for the tested conditions. The survival of head lice depended on temperature, humidity, and exposure time. The optimal conditions for head lice were 18 masculineC and 97% relative humidity at 18 h of exposition. The insecticidal activity of three monoterpenoids (pulegone, linalool, and 1,8-cineole), evaluated according the selected conditions by topical application, showed no significant differences between males of body and head lice. To conclude, as head lice required more special laboratory conditions than body lice, the optimal head lice conditions should be used in both organisms in comparative bioassays. Body louse is an appropriate organism for testing products against of head louse.

  7. 48 CFR 702.170-9 - Head of agency.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Head of agency. 702.170-9 Section 702.170-9 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT GENERAL DEFINITIONS OF WORDS AND TERMS Definitions 702.170-9 Head of agency. Head of agency means, for USAID, the...

  8. 49 CFR 179.16 - Tank-head puncture-resistance systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... CARS General Design Requirements § 179.16 Tank-head puncture-resistance systems. (a) Performance...; and (3) The impacted tank car is pressurized to at least 6.9 Bar (100 psig). (b) Verification by... design and test requirements of the full-head protection (shields) or full tank-head jackets must meet...

  9. WE-G-BRB-08: TG-51 Calibration of First Commercial MRI-Guided IMRT System in the Presence of 0.35 Tesla Magnetic Field.

    PubMed

    Goddu, S; Green, O Pechenaya; Mutic, S

    2012-06-01

    The first real-time-MRI-guided radiotherapy system has been installed in a clinic and it is being evaluated. Presence of magnetic field (MF) during radiation output calibration may have implications on ionization measurements and there is a possibility that standard calibration protocols may not be suitable for dose measurements for such devices. In this study, we evaluated whether a standard calibration protocol (AAPM- TG-51) is appropriate for absolute dose measurement in presence of MF. Treatment delivery of the ViewRay (VR) system is via three 15,000Ci Cobalt-60 heads positioned 120-degrees apart and all calibration measurements were done in the presence of 0.35T MF. Two ADCL- calibrated ionization-chambers (Exradin A12, A16) were used for TG-51 calibration. Chambers were positioned at 5-cm depth, (SSD=105cm: VR's isocenter), and the MLC leaves were shaped to a 10.5cm × 10.5 cm field size. Percent-depth-dose (PDD) measurements were performed for 5 and 10 cm depths. Individual output of each head was measured using the AAPM- TG51 protocol. Calibration accuracy for each head was subsequently verified by Radiological Physics Center (RPC) TLD measurements. Measured ion-recombination (Pion) and polarity (Ppol) correction factors were less-than 1.002 and 1.006, respectively. Measured PDDs agreed with BJR-25 within ±0.2%. Maximum dose rates for the reference field size at VR's isocenter for heads 1, 2 and 3 were 1.445±0.005, 1.446±0.107, 1.431±0.006 Gy/minute, respectively. Our calibrations agreed with RPC- TLD measurements within ±1.3%, ±2.6% and ±2.0% for treatment-heads 1, 2 and 3, respectively. At the time of calibration, mean activity of the Co-60 sources was 10,800Ci±0.1%. This study shows that the TG- 51 calibration is feasible in the presence of 0.35T MF and the measurement agreement is within the range of results obtainable for conventional treatment machines. Drs. Green, Goddu, and Mutic served as scientific consultants for ViewRay, Inc. Dr. Mutic is on the clinical focus group for ViewRay, Inc., and his spouse holds shares in ViewRay, Inc. © 2012 American Association of Physicists in Medicine.

  10. Head capsule, chephalic central nervous system and head circulatory system of an aberrant orthopteran, Prosarthria teretrirostris (Caelifera, Hexapoda).

    PubMed

    Baum, Eileen; Hertel, Wieland; Beutel, Rolf Georg

    2007-01-01

    The head capsule, the circulatory system and the central nervous system of the head of Prosarthria teretrirostris (Proscopiidae) is described in detail, with special consideration of modifications resulting from the aberrant head shape. The transformations of the head are completely different from those found in phasmatodeans, which are also characterised by twig mimesis. The circulatory system is distinctly modified. A hitherto undescribed additional structure in the posterior head region very likely functions as a pulsatile organ. The cephalic central nervous system is strongly elongated, with changes in the position of the suboesophageal ganglion, the corpora cardiaca and the course of the nervus mandibularis. Three-dimensional reconstructions of these two organ systems in combination with the pharynx were made using Alias Maya 6.0 software. Comparisons with other representatives of Caelifera suggest a clade comprising Proscopiidae and Morabinae. The presence of a transverse muscle connecting the antennal ampullae in Prosarthria shows that this structure likely belongs to the groundplan of Orthoptera, even though it is missing in different representatives of this group. The transverse ampullary muscle is a potential synapomorphy of Orthoptera, Phasmatodea and Dictyoptera.

  11. Have cementless and resurfacing components improved the medium-term results of hip replacement for patients under 60 years of age?

    PubMed Central

    Mason, James; Baker, Paul; Gregg, Paul J; Porter, Martyn; Deehan, David J; Reed, Mike R

    2015-01-01

    Background and purpose The optimal hip replacement for young patients remains unknown. We compared patient-reported outcome measures (PROMs), revision risk, and implant costs over a range of hip replacements. Methods We included hip replacements for osteoarthritis in patients under 60 years of age performed between 2003 and 2010 using the commonest brand of cemented, cementless, hybrid, or resurfacing prosthesis (11,622 women and 13,087 men). The reference implant comprised a cemented stem with a conventional polyethylene cemented cup and a standard-sized head (28- or 32-mm). Differences in implant survival were assessed using competing-risks models, adjusted for known prognostic influences. Analysis of covariance was used to assess improvement in PROMs (Oxford hip score (OHS) and EQ5D index) in 2014 linked procedures. Results In males, PROMs and implant survival were similar across all types of implants. In females, revision was statistically significantly higher in hard-bearing and/or small-stem cementless implants (hazard ratio (HR) = 4) and resurfacings (small head sizes (< 48 mm): HR = 6; large head sizes (≥ 48 mm): HR = 5) when compared to the reference cemented implant. In component combinations with equivalent survival, women reported significantly greater improvements in OHS with hybrid implants (22, p = 0.006) and cementless implants (21, p = 0.03) (reference, 18), but similar EQ5D index. For men and women, National Health Service (NHS) costs were lowest with the reference implant and highest with a hard-bearing cementless replacement. Interpretation In young women, hybrids offer a balance of good early functional improvement and low revision risk. Fully cementless and resurfacing components are more costly and do not provide any additional benefit for younger patients. PMID:25285617

  12. Unsupervised Segmentation of Head Tissues from Multi-modal MR Images for EEG Source Localization.

    PubMed

    Mahmood, Qaiser; Chodorowski, Artur; Mehnert, Andrew; Gellermann, Johanna; Persson, Mikael

    2015-08-01

    In this paper, we present and evaluate an automatic unsupervised segmentation method, hierarchical segmentation approach (HSA)-Bayesian-based adaptive mean shift (BAMS), for use in the construction of a patient-specific head conductivity model for electroencephalography (EEG) source localization. It is based on a HSA and BAMS for segmenting the tissues from multi-modal magnetic resonance (MR) head images. The evaluation of the proposed method was done both directly in terms of segmentation accuracy and indirectly in terms of source localization accuracy. The direct evaluation was performed relative to a commonly used reference method brain extraction tool (BET)-FMRIB's automated segmentation tool (FAST) and four variants of the HSA using both synthetic data and real data from ten subjects. The synthetic data includes multiple realizations of four different noise levels and several realizations of typical noise with a 20% bias field level. The Dice index and Hausdorff distance were used to measure the segmentation accuracy. The indirect evaluation was performed relative to the reference method BET-FAST using synthetic two-dimensional (2D) multimodal magnetic resonance (MR) data with 3% noise and synthetic EEG (generated for a prescribed source). The source localization accuracy was determined in terms of localization error and relative error of potential. The experimental results demonstrate the efficacy of HSA-BAMS, its robustness to noise and the bias field, and that it provides better segmentation accuracy than the reference method and variants of the HSA. They also show that it leads to a more accurate localization accuracy than the commonly used reference method and suggest that it has potential as a surrogate for expert manual segmentation for the EEG source localization problem.

  13. Head Start Improvement Act of 2014

    THOMAS, 113th Congress

    Rep. Salmon, Matt [R-AZ-5

    2014-04-10

    House - 06/13/2014 Referred to the Subcommittee on Early Childhood, Elementary, and Secondary Education. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  14. How do reference montage and electrodes setup affect the measured scalp EEG potentials?

    NASA Astrophysics Data System (ADS)

    Hu, Shiang; Lai, Yongxiu; Valdes-Sosa, Pedro A.; Bringas-Vega, Maria L.; Yao, Dezhong

    2018-04-01

    Objective. Human scalp electroencephalogram (EEG) is widely applied in cognitive neuroscience and clinical studies due to its non-invasiveness and ultra-high time resolution. However, the representativeness of the measured EEG potentials for the underneath neural activities is still a problem under debate. This study aims to investigate systematically how both reference montage and electrodes setup affect the accuracy of EEG potentials. Approach. First, the standard EEG potentials are generated by the forward calculation with a single dipole in the neural source space, for eleven channel numbers (10, 16, 21, 32, 64, 85, 96, 128, 129, 257, 335). Here, the reference is the ideal infinity implicitly determined by forward theory. Then, the standard EEG potentials are transformed to recordings with different references including five mono-polar references (Left earlobe, Fz, Pz, Oz, Cz), and three re-references (linked mastoids (LM), average reference (AR) and reference electrode standardization technique (REST)). Finally, the relative errors between the standard EEG potentials and the transformed ones are evaluated in terms of channel number, scalp regions, electrodes layout, dipole source position and orientation, as well as sensor noise and head model. Main results. Mono-polar reference recordings are usually of large distortions; thus, a re-reference after online mono-polar recording should be adopted in general to mitigate this effect. Among the three re-references, REST is generally superior to AR for all factors compared, and LM performs worst. REST is insensitive to head model perturbation. AR is subject to electrodes coverage and dipole orientation but no close relation with channel number. Significance. These results indicate that REST would be the first choice of re-reference and AR may be an alternative option for high level sensor noise case. Our findings may provide the helpful suggestions on how to obtain the EEG potentials as accurately as possible for cognitive neuroscientists and clinicians.

  15. Heading in the right direction? An innovative approach toward proper patient head positioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grush, William H.; Steffen, Gary A

    2002-12-31

    An in-house-manufactured modification of the standard A-F foam rubber head-neck supports (aka. Timo Supports) was designed to eliminate clinical setup problems with head immobilization and instability during treatment, thus providing for a more comfortable head rest for the patient. The custom design of this head holder seeks to eliminate superior-to-inferior shift, and minimize the lateral right-to-left rotational movement of the head when coupled with an AquaPlast casting system. By focusing attention to the seating of the occipital portion of the head and contour of the patient's neck, the aforementioned problems of movement were addressed, while adhering to the interests ofmore » patient comfort in this modified head support system.« less

  16. [Neurology in the medical papyruses of the pharaohs].

    PubMed

    García-Albea, E

    The civilization of Ancient Egypt included a long period of almost three millenniums, and is the most interesting example of the so-called pretechnical archaic cultures. Papyrus scrolls are the main source of information about medical activities. There are fourteen medical papyrus scrolls, in varying states of conservation, mostly corresponding to the Middle Empire, but containing references to the Ancient Empire (the period of the pyramids). These are practical treaties with little explanation of the underlying pathology (a primitive theory of the 'flow' of humors, involving the flowing of different malignant entities) within a system of magic and religion. The empirical observations referring to diseases or dysfunctions of the nervous system, although few, seem to be worth reviewing. Remedies for migraine ('the disorder affecting half the head') take up a long chapter of the only complete and best preserved Ebers papyrus. Dementia (deterioration with age), convulsions and tetany are briefly mentioned in several papyrus scrolls. With the detailed description of the clinical findings of cranial and vertebral trauma, and the orderly assessment of severity presented in Edwin Smith's papyrus the neurology of pharaonic Egypt attained its greatest importance.

  17. Multi-modal cockpit interface for improved airport surface operations

    NASA Technical Reports Server (NTRS)

    Arthur, Jarvis J. (Inventor); Bailey, Randall E. (Inventor); Prinzel, III, Lawrence J. (Inventor); Kramer, Lynda J. (Inventor); Williams, Steven P. (Inventor)

    2010-01-01

    A system for multi-modal cockpit interface during surface operation of an aircraft comprises a head tracking device, a processing element, and a full-color head worn display. The processing element is configured to receive head position information from the head tracking device, to receive current location information of the aircraft, and to render a virtual airport scene corresponding to the head position information and the current aircraft location. The full-color head worn display is configured to receive the virtual airport scene from the processing element and to display the virtual airport scene. The current location information may be received from one of a global positioning system or an inertial navigation system.

  18. Krabbe disease

    MedlinePlus

    ... the amount of protein in cerebrospinal fluid (CSF) Genetic testing MRI of the head Nerve conduction velocity Testing for the GALC gene defect Treatment There is no specific ... Genetics Home Reference -- ghr.nlm.nih.gov/condition/krabbe- ...

  19. Comparing discriminant analysis and neural network for the determination of sex using femur head measurements.

    PubMed

    Alunni, Véronique; Jardin, Philippe du; Nogueira, Luisa; Buchet, Luc; Quatrehomme, Gérald

    2015-08-01

    The measurement of the femoral head is usually considered an interesting variable for the sex determination of skeletal remains. To date, there are few published reference measurements of the femoral head in a modern European population for the purpose of sex determination. In this study, 116 femurs from 58 individuals of the South of France (Nice Bone Collection, Nice, France) were studied. Three measurements of the femoral head were taken: the vertical head diameter (VHD), the transversal head diameter (THD) and the head circumference (HC). The results show that: (i) there is no statistical difference between the right and left femurs for each of the three measurements (VHD, THD and HC). Therefore we arbitrarily chose to use the measures from the right femurs (N=58) to pursue our experiments; (ii) the measurements of the femoral head are similar to those of contemporary American populations; (iii) the dimensions of the femoral head place the measurements of the French population somewhere between Germany or Croatia, and Spain; (iv) there is no significant secular trend (in contrast with the femoral neck diameter); (v) the femoral head measurement as a single variable is useful for sex determination: a 96.5% rate of accuracy was obtained using THD and HC measurements with the artificial neural network; and a 94.8% rate of accuracy using VHD, both with the discriminant analysis and the neural network. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Ionization detection system for aerosols

    DOEpatents

    Jacobs, Martin E.

    1977-01-01

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system utilizes a measuring ionization chamber which is modified to minimize false alarms and reductions in sensitivity resulting from changes in ambient temperature. In the preferred form of the modification, an annular radiation shield is mounted about the usual radiation source provided to effect ionization in the measuring chamber. The shield is supported by a bimetallic strip which flexes in response to changes in ambient temperature, moving the shield relative to the source so as to vary the radiative area of the source in a manner offsetting temperature-induced variations in the sensitivity of the chamber.

  1. Performance evaluation of a LYSO-based PET scanner for monitoring of dose delivery in hadrontherapy

    NASA Astrophysics Data System (ADS)

    Fabbiani, E.; Belcari, N.; Camarlinghi, N.; Del Guerra, A.; Ferretti, S.; Kraan, A.; Panetta, D.; Sportelli, G.; Rosso, V.

    2015-12-01

    The DoPET scanner is a compact positron emission tomography (PET) device. It has been developed for monitoring the range of charged particles during therapy with hadron beams. Previous works have focused on the development and upgrade of the device and on data analysis. In this paper, a full performance characterization of the DoPET system in terms of the energy resolution, spatial resolution, sensitivity, uniformity, and noise equivalent count rate is reported. All measurements refer to an adapted version of the National Electrical Manufacturers Association (NEMA) NU 4 - 2008 protocol, which was written originally for small animal PET systems. Since DoPET is a dual head planar system, it requires a modified characterisation procedure with respect to those described for ring geometries as in the NEMA NU 4 - 2008 protocol. The presented procedure may be of interest for any other PET system with a similar geometry as DoPET.

  2. Completed Research in Health, Physical Education, and Recreation Including International Sources. Volume 17, 1975 Edition Covering Research Completed in 1974.

    ERIC Educational Resources Information Center

    Thomas, Jerry R., Ed.; Weiss, Raymond A., Ed.

    This compilation lists research completed in health, physical education, and allied areas during 1974. It is arranged in three parts. Part one is an index which cross references the listings in parts two and three. References are arranged under subject headings, which are in alphabetical order. Instructions for using the index are also given in…

  3. Completed Research in Health, Physical Education and Recreation Including International Sources. Volume 22. 1980 Edition. Covering Research Completed in 1979.

    ERIC Educational Resources Information Center

    Rothstein, Anne L., Ed.; Nelson, Jack, Ed.

    This compilation lists research completed in the areas of health, physical education, recreation, and allied areas during 1979. It is arranged in three parts. Part one, the index, gives cross references for all the listings in parts two and three. References are arranged alphabetically under the subject headings. Part two contains a bibliography…

  4. Realization of a CORDIC-Based Plug-In Accelerometer Module for PSG System in Head Position Monitoring for OSAS Patients

    PubMed Central

    Chou, Wen-Cheng; Shiao, Tsu-Hui; Shiao, Guang-Ming; Luo, Chin-Shan

    2017-01-01

    Overnight polysomnography (PSG) is currently the standard diagnostic procedure for obstructive sleep apnea (OSA). It has been known that monitoring of head position in sleep is crucial not only for the diagnosis (positional sleep apnea) but also for the management of OSA (positional therapy). However, there are no sensor systems available clinically to hook up with PSG for accurate head position monitoring. In this paper, an accelerometer-based sensing system for accurate head position monitoring is developed and realized. The core CORDIC- (COordinate Rotation DIgital Computer-) based tilting sensing algorithm is realized in the system to quickly and accurately convert accelerometer raw data into the desired head position tilting angles. The system can hook up with PSG devices for diagnosis to have head position information integrated with other PSG-monitored signals. It has been applied in an IRB test in Taipei Veterans General Hospital and has been proved that it can meet the medical needs of accurate head position monitoring for PSG diagnosis. PMID:29065608

  5. Genetics Home Reference: Potocki-Shaffer syndrome

    MedlinePlus

    ... parietal foramina ). These abnormal openings form extra "soft spots" on the head, in addition to the two ... newborns normally have. Unlike the usual newborn soft spots, the enlarged parietal foramina remain open throughout life. ...

  6. Gender and the Orthodoxies of Leadership.

    ERIC Educational Resources Information Center

    Coleman, Marianne

    2003-01-01

    Examines two orthodoxies related to leadership and gender: Leadership is vested in males, and male leadership style is "macho." Draws implications for leadership role of female head teachers. (Contains 5 tables and 33 reference.) (PKP)

  7. Head Start Improvement Act of 2014

    THOMAS, 113th Congress

    Sen. Lee, Mike [R-UT

    2014-03-12

    Senate - 03/12/2014 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  8. Intrathoracic and venous pressure relationships during responses to changes in body position

    NASA Technical Reports Server (NTRS)

    Avasthey, P.; Wood, E. H.

    1974-01-01

    Simultaneous end-expiratory pressures, referred to midthoracic level, in the superior and abdominal venae cavae, pericardial space, and right and left heart, were recorded without thoracotomy in three anesthetized dogs during sudden changes from supine to vertical head-up or head-down body positions. Intrathoracic and dependent great vein pressures referred to midchest level (sixth thoracic vertebra) decreased and showed simple hydrostatic gradients in either vertical position. However, a discontinuity in the large vein hydrostatic gradient occurred just distal to the superior margin of the thorax in either body position and was resumed again above this level. It is concluded that, just as the cerebrospinal fluid and intraperitoneal pressures minimize the effects of gravitational and inertial forces on the cerebral and visceral circulations, the pericardial and pleural pressures have a similar role for the heart proper.

  9. Head injury in asylum seekers and refugees referred with psychological trauma.

    PubMed

    Doherty, S M; Craig, R; Gardani, M; McMillan, T M

    2016-01-01

    Individuals who seek asylum are frequently fleeing violent persecution and may experience head injury (HI). However, little is known about the prevalence of HI in asylum seekers and refugees (ASR) despite the potential for HI to significantly affect cognitive and emotional functioning and to compromise asylum outcomes. This preliminary study investigates the prevalence of HI in ASR referred to a complex psychological trauma service. Participants were 115 adult ASR referred to a community psychological trauma service with moderate to severe mental health problems associated with psychological trauma. They were screened for a history of HI using a questionnaire developed for the study. Interpreters were used when required. The overall prevalence of HI was 51%. At least 38% of those with HI had a moderate-severe HI that could cause persisting disability. In 53% of those with HI, the cause was torture, human trafficking or domestic violence. Repeat HI can have cumulative effects on function; it was common, and was reported in 68% of those with HI. An injury to the head was not known to mental health clinicians prior to screening in 64% of cases. The emotional and cognitive consequences of HI in ASR may increase the vulnerability of this disadvantaged group, and can be associated with neurobehavioural problems affecting daily life and may compromise asylum outcomes. Routine screening for HI in ASR is needed, as are links to neuropsychology and brain injury services for advice, assessment and intervention.

  10. Proceedings of the Environmental Research and Development (R&D) technical Workshop Held in San Diego, California on 7-9 November 1989

    DTIC Science & Technology

    1990-06-01

    Released by Under authority of P. F. Seligman , Head S. Yamamoto, Head Marine Environment Branch Environmental Sciences Division NOTE: The front cover...168 ENVIRONMENT Peter F. Seligman Code 522, NOSC San Diego, CA 92152-5000 AUTOVON 553-2778, (619) 553-2778 IL 99 DEVELOPMENT OF INNOVATIVE...hour monitoring tests. The suggested ad- ditions will be implemented in version 3.9 as funding permits. REFERENCES 1. Clavell, C., Seligman , P. F, and

  11. Program finds centrifugal compressor operating point

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campos, M.C.M.M.; Rodrigues, P.S.B.

    1990-09-01

    This article presents the Scop program, a computational procedure developed using Fortran 77 language to find the operating point of centrifugal compressors starting from performance curves. Characteristics or performance curves traditionally are employed by manufacturers to inform users about turbocompressor behavior. Usually, these curves have polytropic head, H, and corresponding polytropic efficiency, {eta} plus rotation speed, N, and inlet volumetric flowrate, Q, as parameters. Two families of curves can be identified in this figure. One provides head-flow relationships for several speeds and the other refers to isoefficiency curves.

  12. An Interpreters Interpretation: Sign Language Interpreters View of Musculoskeletal Disorders

    DTIC Science & Technology

    2004-01-01

    to describe their pain (e.g. “I feel a band of iron around my head , like carrying a heavy crown”, implying that medical staff need to clarify the... aching , stiffness, burning, numbness, or tingling in the neck (73.6%), hand/wrist (69.6%), and/or shoulder (60.0%). While less than half of those...the term supervisor is meant to refer to the boss, manager, department head , or the person or persons to whom an employee reports. For each question

  13. Growing a National Learning Environments and Resources Network for Science, Mathematics, Engineering, and Technology Education: Current Issues and Opportunities for the NSDL Program; Open Linking in the Scholarly Information Environment Using the OpenURL Framework; The HeadLine Personal Information Environment: Evaluation Phase One.

    ERIC Educational Resources Information Center

    Zia, Lee L.; Van de Sompel, Herbert; Beit-Arie, Oren; Gambles, Anne

    2001-01-01

    Includes three articles that discuss the National Science Foundation's National Science, Mathematics, Engineering, and Technology Education Digital Library (NSDL) program; the OpenURL framework for open reference linking in the Web-based scholarly information environment; and HeadLine (Hybrid Electronic Access and Delivery in the Library Networked…

  14. Lunar Navigation Determination System - LaNDS

    NASA Technical Reports Server (NTRS)

    Quinn, David; Talabac, Stephen

    2012-01-01

    A portable comprehensive navigational system has been developed that both robotic and human explorers can use to determine their location, attitude, and heading anywhere on the lunar surface independent of external infrastructure (needs no Lunar satellite network, line of sight to the Sun or Earth, etc.). The system combines robust processing power with an extensive topographical database to create a real-time atlas (GIS Geospatial Information System) that is able to autonomously control and monitor both single unmanned rovers and fleets of rovers, as well as science payload stations. The system includes provisions for teleoperation and tele-presence. The system accepts (but does not require) inputs from a wide range of sensors. A means was needed to establish a location when the search is taken deep in a crater (looking for water ice) and out of view of Earth or any other references. A star camera can be employed to determine the user's attitude in menial space and stellar map in body space. A local nadir reference (e.g., an accelerometer that orients the nadir vector in body space) can be used in conjunction with a digital ephemeris and gravity model of the Moon to isolate the latitude, longitude, and azimuth of the user on the surface. That information can be used in conjunction with a Lunar GIS and advanced navigation planning algorithms to aid astronauts (or other assets) to navigate on the Lunar surface.

  15. Comparative study of an argon plasma and an argon copper plasma produced by an ICP torch at atmospheric pressure based on spectroscopic methods

    NASA Astrophysics Data System (ADS)

    Bussière, W.; Vacher, D.; Menecier, S.; André, P.

    2012-04-01

    In three places in this paper, the citation of reference [43] quotes a further reference [61] cited therein. This in fact should be the reference [45] cited in [43]. This occurs in the caption of figure 3; at the top of the right-hand column on page 6; and in the paragraph headed Influence of the Biberman factor value on page 18. In each case, the text: '[43] (especially reference [61] therein)' should be replaced by '[43] (especially reference [45] therein)'. The authors would like to thank Dr L G D'yachkov for having pointed out the error.

  16. An overview of the BIOASQ large-scale biomedical semantic indexing and question answering competition.

    PubMed

    Tsatsaronis, George; Balikas, Georgios; Malakasiotis, Prodromos; Partalas, Ioannis; Zschunke, Matthias; Alvers, Michael R; Weissenborn, Dirk; Krithara, Anastasia; Petridis, Sergios; Polychronopoulos, Dimitris; Almirantis, Yannis; Pavlopoulos, John; Baskiotis, Nicolas; Gallinari, Patrick; Artiéres, Thierry; Ngomo, Axel-Cyrille Ngonga; Heino, Norman; Gaussier, Eric; Barrio-Alvers, Liliana; Schroeder, Michael; Androutsopoulos, Ion; Paliouras, Georgios

    2015-04-30

    This article provides an overview of the first BIOASQ challenge, a competition on large-scale biomedical semantic indexing and question answering (QA), which took place between March and September 2013. BIOASQ assesses the ability of systems to semantically index very large numbers of biomedical scientific articles, and to return concise and user-understandable answers to given natural language questions by combining information from biomedical articles and ontologies. The 2013 BIOASQ competition comprised two tasks, Task 1a and Task 1b. In Task 1a participants were asked to automatically annotate new PUBMED documents with MESH headings. Twelve teams participated in Task 1a, with a total of 46 system runs submitted, and one of the teams performing consistently better than the MTI indexer used by NLM to suggest MESH headings to curators. Task 1b used benchmark datasets containing 29 development and 282 test English questions, along with gold standard (reference) answers, prepared by a team of biomedical experts from around Europe and participants had to automatically produce answers. Three teams participated in Task 1b, with 11 system runs. The BIOASQ infrastructure, including benchmark datasets, evaluation mechanisms, and the results of the participants and baseline methods, is publicly available. A publicly available evaluation infrastructure for biomedical semantic indexing and QA has been developed, which includes benchmark datasets, and can be used to evaluate systems that: assign MESH headings to published articles or to English questions; retrieve relevant RDF triples from ontologies, relevant articles and snippets from PUBMED Central; produce "exact" and paragraph-sized "ideal" answers (summaries). The results of the systems that participated in the 2013 BIOASQ competition are promising. In Task 1a one of the systems performed consistently better from the NLM's MTI indexer. In Task 1b the systems received high scores in the manual evaluation of the "ideal" answers; hence, they produced high quality summaries as answers. Overall, BIOASQ helped obtain a unified view of how techniques from text classification, semantic indexing, document and passage retrieval, question answering, and text summarization can be combined to allow biomedical experts to obtain concise, user-understandable answers to questions reflecting their real information needs.

  17. The development and evaluation of head probes for optical imaging of the infant head

    NASA Astrophysics Data System (ADS)

    Branco, Gilberto

    The objective of this thesis was to develop and evaluate optical imaging probes for mapping oxygenation and haemodynamic changes in the newborn infant brain. Two imaging approaches are being developed at University College London (UCL): optical topography (surface mapping of the cortex) and optical tomography (volume imaging). Both have the potential to provide information about the function of the normal brain and about a variety of neurophysiologies! abnormalities. Both techniques require an array of optical fibres/fibre bundles to be held in contact with the head, for periods of time from tens of seconds to an hour or more. The design of suitable probes must ensure the comfort and safety of the subject, and provide measurements minimally sensitive to external sources of light and patient motion. A series of prototype adaptable helmets were developed for optical tomography of the premature infant brain using the UCL 32-channel time-resolved system. They were required to attach 32 optical fibre bundles over the infant scalp, and were designed to accommodate infants with a variety of head shapes and sizes, aged between 24-weeks gestational age and term. Continual improvements to the helmet design were introduced following the evaluation of each prototype on infants in the hospital. Data were acquired to generate images revealing the concentration and oxygenation of blood in the brain, and the response of the brain to sensory stimulation. This part of the project also involved designing and testing new methods of acquiring calibration data using reference phantoms. The second focus of the project was the development of probes for use with the UCL frequency-multiplexed near-infrared topography system. This is being used to image functional activation in the infant cortex. A series of probes were developed and experiments were conducted to evaluate their sensitivity to patient motion and to compression of the probe. The probes have been used for a variety of functional activation studies.

  18. MRI Sequences in Head & Neck Radiology - State of the Art.

    PubMed

    Widmann, Gerlig; Henninger, Benjamin; Kremser, Christian; Jaschke, Werner

    2017-05-01

    Background  Magnetic resonance imaging (MRI) has become an essential imaging modality for the evaluation of head & neck pathologies. However, the diagnostic power of MRI is strongly related to the appropriate selection and interpretation of imaging protocols and sequences. The aim of this article is to review state-of-the-art sequences for the clinical routine in head & neck MRI and to describe the evidence for which medical question these sequences and techniques are useful. Method  Literature review of state-of-the-art sequences in head & neck MRI. Results and Conclusion  Basic sequences (T1w, T2w, T1wC+) and fat suppression techniques (TIRM/STIR, Dixon, Spectral Fat sat) are important tools in the diagnostic workup of inflammation, congenital lesions and tumors including staging. Additional sequences (SSFP (CISS, FIESTA), SPACE, VISTA, 3D-FLAIR) are used for pathologies of the cranial nerves, labyrinth and evaluation of endolymphatic hydrops in Menière's disease. Vessel and perfusion sequences (3D-TOF, TWIST/TRICKS angiography, DCE) are used in vascular contact syndromes, vascular malformations and analysis of microvascular parameters of tissue perfusion. Diffusion-weighted imaging (EPI-DWI, non-EPI-DWI, RESOLVE) is helpful in cholesteatoma imaging, estimation of malignancy, and evaluation of treatment response and posttreatment recurrence in head & neck cancer. Understanding of MRI sequences and close collaboration with referring physicians improves the diagnostic confidence of MRI in the daily routine and drives further research in this fascinating image modality. Key Points:   · Understanding of MRI sequences is essential for the correct and reliable interpretation of MRI findings.. · MRI protocols have to be carefully selected based on relevant clinical information.. · Close collaboration with referring physicians improves the output obtained from the diagnostic possibilities of MRI.. Citation Format · Widmann G, Henninger B, Kremser C et al. MRI Sequences in Head & Neck Radiology - State of the Art. Fortschr Röntgenstr 2017; 189: 413 - 422. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Spatial transformations between superior colliculus visual and motor response fields during head-unrestrained gaze shifts.

    PubMed

    Sadeh, Morteza; Sajad, Amirsaman; Wang, Hongying; Yan, Xiaogang; Crawford, John Douglas

    2015-12-01

    We previously reported that visuomotor activity in the superior colliculus (SC)--a key midbrain structure for the generation of rapid eye movements--preferentially encodes target position relative to the eye (Te) during low-latency head-unrestrained gaze shifts (DeSouza et al., 2011). Here, we trained two monkeys to perform head-unrestrained gaze shifts after a variable post-stimulus delay (400-700 ms), to test whether temporally separated SC visual and motor responses show different spatial codes. Target positions, final gaze positions and various frames of reference (eye, head, and space) were dissociated through natural (untrained) trial-to-trial variations in behaviour. 3D eye and head orientations were recorded, and 2D response field data were fitted against multiple models by use of a statistical method reported previously (Keith et al., 2009). Of 60 neurons, 17 showed a visual response, 12 showed a motor response, and 31 showed both visual and motor responses. The combined visual response field population (n = 48) showed a significant preference for Te, which was also preferred in each visual subpopulation. In contrast, the motor response field population (n = 43) showed a preference for final (relative to initial) gaze position models, and the Te model was statistically eliminated in the motor-only population. There was also a significant shift of coding from the visual to motor response within visuomotor neurons. These data confirm that SC response fields are gaze-centred, and show a target-to-gaze transformation between visual and motor responses. Thus, visuomotor transformations can occur between, and even within, neurons within a single frame of reference and brain structure. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  20. Diagnostic Discrepancies in Mandatory Slide Review of Extradepartmental Head and Neck Cases: Experience at a Large Academic Center.

    PubMed

    Mehrad, Mitra; Chernock, Rebecca D; El-Mofty, Samir K; Lewis, James S

    2015-12-01

    Medical error is a significant problem in the United States, and pathologic diagnoses are a significant source of errors. Prior studies have shown that second-opinion pathology review results in clinically major diagnosis changes in approximately 0.6% to 5.8% of patients. The few studies specifically on head and neck pathology have suggested rates of changed diagnoses that are even higher. Objectives .- To evaluate the diagnostic discrepancy rates in patients referred to our institution, where all such cases are reviewed by a head and neck subspecialty service, and to identify specific areas with more susceptibility to errors. Five hundred consecutive, scanned head and neck pathology reports from patients referred to our institution were compared for discrepancies between the outside and in-house diagnoses. Major discrepancies were defined as those resulting in a significant change in patient clinical management and/or prognosis. Major discrepancies occurred in 20 cases (4% overall). Informative follow-up material was available on 11 of the 20 patients (55.0%), among whom, the second opinion was supported in 11 of 11 cases (100%). Dysplasia versus invasive squamous cell carcinoma was the most common (7 of 20; 35%) area of discrepancy, and by anatomic subsite, the sinonasal tract (4 of 21; 19.0%) had the highest rate of discrepant diagnoses. Of the major discrepant diagnoses, 12 (12 of 20; 60%) involved a change from benign to malignant, one a change from malignant to benign (1 of 20; 5%), and 6 involved tumor classification (6 of 20; 30%). Head and neck pathology is a relatively high-risk area, prone to erroneous diagnoses in a small fraction of patients. This study supports the importance of second-opinion review by subspecialized pathologists for the best care of patients.

  1. The Effect of Piston-Head Temperature on Knock-Limited Power

    NASA Technical Reports Server (NTRS)

    Imming, Harry S.

    1944-01-01

    To determine the effect of piston-head temperature on knock-limited power. Tests were made in a supercharged CFR engine over a range of fuel-air ratios from 0.055 to 0.120, using S-3 reference fuel, AN-F-28, Amendment-2, aviation gasoline, and AN-F-28 plus 2 percent xylidines by weight. Tests were run at a compression ratio of 7.0 with inlet-air temperatures of 150 F and 250 F and at a compression ratio of 8.0 with an inlet-air temperature of 250 F. All other engine conditions were held constant. The piston-head temperature was varied by circulation of oil through passages in the crown of a liquid-cooled piston. This method of piston cooling decreased the piston-head temperature about 80 F. The data are not intended to constitute a recommendation as to the advisability of piston cooling in practice.

  2. Fast in-situ tool inspection based on inverse fringe projection and compact sensor heads

    NASA Astrophysics Data System (ADS)

    Matthias, Steffen; Kästner, Markus; Reithmeier, Eduard

    2016-11-01

    Inspection of machine elements is an important task in production processes in order to ensure the quality of produced parts and to gather feedback for the continuous improvement process. A new measuring system is presented, which is capable of performing the inspection of critical tool geometries, such as gearing elements, inside the forming machine. To meet the constraints on sensor head size and inspection time imposed by the limited space inside the machine and the cycle time of the process, the measuring device employs a combination of endoscopy techniques with the fringe projection principle. Compact gradient index lenses enable a compact design of the sensor head, which is connected to a CMOS camera and a flexible micro-mirror based projector via flexible fiber bundles. Using common fringe projection patterns, the system achieves measuring times of less than five seconds. To further reduce the time required for inspection, the generation of inverse fringe projection patterns has been implemented for the system. Inverse fringe projection speeds up the inspection process by employing object-adapted patterns, which enable the detection of geometry deviations in a single image. Two different approaches to generate object adapted patterns are presented. The first approach uses a reference measurement of a manufactured tool master to generate the inverse pattern. The second approach is based on a virtual master geometry in the form of a CAD file and a ray-tracing model of the measuring system. Virtual modeling of the measuring device and inspection setup allows for geometric tolerancing for free-form surfaces by the tool designer in the CAD-file. A new approach is presented, which uses virtual tolerance specifications and additional simulation steps to enable fast checking of metric tolerances. Following the description of the pattern generation process, the image processing steps required for inspection are demonstrated on captures of gearing geometries.

  3. Japanese Board Certification System for head and neck surgeons.

    PubMed

    Yoshimoto, Seiichi; Nakashima, Torahiko; Fujii, Takashi; Matsuura, Kazuto; Otsuki, Naoki; Asakage, Takahiro; Fujimoto, Yasushi; Hanai, Nobuhiro; Homma, Akihiro; Monden, Nobuya; Okami, Kenji; Sugasawa, Masashi; Hasegawa, Yasuhisa; Nibu, Ken-ichi; Kamata, Shin-etsu; Kishimoto, Seiji; Kohno, Naoyuki; Fukuda, Satoshi; Hisa, Yasuo

    2014-08-01

    The Japan Society for Head and Neck Surgery (JSHNS) started a board certification system for head and neck surgeons in 2010. To become certified, the following qualification and experiences are required: (1) board certification as otorhinolaryngologist, (2) 2 years of clinical experience in a board-certified training facility, (3) clinical care of 100 patients with head and neck cancer under the supervision of board-certified faculty and (4) surgical experience in 50 major head and neck surgical procedures, including 20 neck dissections, under the supervision of board-certified faculty. The following scientific activities are also required during the preceding 5 years: (1) two clinical papers on head and neck cancers presented at major scientific meetings, (2) one clinical paper on head and neck cancer published in a major journal, (3) attendance at two annual meetings of JSHNS and (4) enrolment in three educational programs approved by JSHNS. The qualifying examination consists of multiple choice tests and oral examinations. A total of 151 head and neck surgeons were certified in 2010 followed by 43 in 2011 and 34 in 2012, while the membership of JSHNS dramatically increased from 1201 in 2007 to 1748 in 2013. Although the board certification system for head and neck surgeons was started only recently, it has encouraged many residents and fellows as well as established head and neck surgeons. We believe that this system will contribute to further advancement in the clinical practice for head and neck cancers in Japan. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Endoscopic fringe projection for in-situ inspection of a sheet-bulk metal forming process

    NASA Astrophysics Data System (ADS)

    Matthias, Steffen; Kästner, Markus; Reithmeier, Eduard

    2015-05-01

    Sheet-bulk metal forming is a new production process capable of performing deep-drawing and massive forming steps in a single operation. However, due to the high forming forces of the forming process, continuous process control is required in order to detect wear on the forming tool before production quality is impacted. To be able to measure the geometry of the forming tool in the limited space of forming presses, a new inspection system is being developed within the SFB/TR 73 collaborative research center. In addition to the limited space, the process restricts the amount of time available for inspection. Existing areal optical measurement systems suffer from shadowing when measuring the tool's inner elements, as they cannot be placed in the limited space next to the tool, while tactile measurement systems cannot meet the time restrictions for measuring the areal geometries. The new inspection system uses the fringe projection optical measurement principle to capture areal geometry data from relevant parts of the forming tool in short time. Highresolution image fibers are used to connect the system's compact sensor head to a base unit containing both camera and projector of the fringe projection system, which can be positioned outside of the moving parts of the press. To enable short measurement times, a high intensity laser source is used in the projector in combination with a digital micro-mirror device. Gradient index lenses are featured in the sensor head to allow for a very compact design that can be used in the narrow space above the forming tool inside the press. The sensor head is attached to an extended arm, which also guides the image fibers to the base unit. A rotation stage offers the possibility to capture measurements of different functional elements on the circular forming tool by changing the orientation of the sensor head next to the forming tool. During operation of the press, the arm can be travelled out of the moving parts of the forming press. To further reduce the measurement times of the fringe projection system, the inverse fringe projection principle has been adapted to the system to detect geometry deviations in a single camera image. Challenges arise from vibrations of both the forming machine and the positioning stages, which are transferred via the extended arm to the sensor head. Vibrations interfere with the analysis algorithms of both encoded and inverse fringe projection and thus impair measurement accuracy. To evaluate the impact of vibrations on the endoscopic system, results of measurements of simple geometries under the influence of vibrations are discussed. The effect of vibrations is imitated by displacing the measurement specimen during the measurement with a linear positioning stage. The concept of the new inspection system is presented within the scope of the TR 73 demonstrational sheet-bulk metal forming process. Finally, the capabilities of the endoscopic fringe projection system are shown by measurements of gearing structures on a forming tool compared to a CAD-reference.

  5. A low-cost GPS/INS integrated vehicle heading angle measurement system

    NASA Astrophysics Data System (ADS)

    Wu, Ye; Gao, Tongyue; Ding, Yi

    2018-04-01

    GPS can provide continuous heading information, but the accuracy is easily affected by the velocity and shelter from buildings or trees. For vehicle systems, we propose a low-cost heading angle update algorithm. Based on the GPS/INS integrated navigation kalman filter, we add the GPS heading angle to the measurement vector, and establish its error model. The experiment results show that this algorithm can effectively improve the accuracy of GPS heading angle.

  6. Assessment of head injury risk associated with feet-first free falls in 12-month-old children using an anthropomorphic test device.

    PubMed

    Thompson, Angela K; Bertocci, Gina; Pierce, Mary Clyde

    2009-04-01

    Short distance falls are a common false history provided in cases of child abuse. Falls are also a common occurrence in ambulating young children. The purpose of this study was to determine the risk of head injury in short distance feet-first free falls for a 12-month-old child. Feet-first free falls were simulated using an anthropomorphic test device. Three fall heights and five surfaces were tested to determine whether changing fall environment characteristics leads to differences in head injury risk outcomes. Linear head accelerations were measured and angular head accelerations in the anterior-posterior direction were determined. Head injury criteria values and impact durations were also determined for each fall. The mean peak linear head acceleration across all trials was 52.2g. HIC15 values were all below the injury assessment reference value. The mean peak angular head acceleration across all trials was 4,246 rad/s2. Impact durations ranged from 12.1 milliseconds to 27.8 milliseconds. In general, head accelerations were greater and impact durations were lower for surfaces with lower coefficients of restitution (a measure of resiliency). In falls onto wood and linoleum over concrete, the ground-based fall was associated with greater accelerations than the two higher fall heights. Results show that fall dynamics play an important role in head injury outcome measures. Different fall heights and impact surfaces led to differences in head injury risk, but the risk of severe head injury across all tested scenarios was low for a 12-month-old child in feet-first free falls.

  7. A new markerless patient-to-image registration method using a portable 3D scanner.

    PubMed

    Fan, Yifeng; Jiang, Dongsheng; Wang, Manning; Song, Zhijian

    2014-10-01

    Patient-to-image registration is critical to providing surgeons with reliable guidance information in the application of image-guided neurosurgery systems. The conventional point-matching registration method, which is based on skin markers, requires expensive and time-consuming logistic support. Surface-matching registration with facial surface scans is an alternative method, but the registration accuracy is unstable and the error in the more posterior parts of the head is usually large because the scan range is limited. This study proposes a new surface-matching method using a portable 3D scanner to acquire a point cloud of the entire head to perform the patient-to-image registration. A new method for transforming the scan points from the device space into the patient space without calibration and tracking was developed. Five positioning targets were attached on a reference star, and their coordinates in the patient space were measured prior. During registration, the authors moved the scanner around the head to scan its entire surface as well as the positioning targets, and the scanner generated a unique point cloud in the device space. The coordinates of the positioning targets in the device space were automatically detected by the scanner, and a spatial transformation from the device space to the patient space could be calculated by registering them to their coordinates in the patient space that had been measured prior. A three-step registration algorithm was then used to register the patient space to the image space. The authors evaluated their method on a rigid head phantom and an elastic head phantom to verify its practicality and to calculate the target registration error (TRE) in different regions of the head phantoms. The authors also conducted an experiment with a real patient's data to test the feasibility of their method in the clinical environment. In the phantom experiments, the mean fiducial registration error between the device space and the patient space, the mean surface registration error, and the mean TRE of 15 targets on the surface of each phantom were 0.34 ± 0.01 mm and 0.33 ± 0.02 mm, 1.17 ± 0.02 mm and 1.34 ± 0.10 mm, and 1.06 ± 0.11 mm and 1.48 ± 0.21 mm, respectively. When grouping the targets according to their positions on the head, high accuracy was achieved in all parts of the head, and the TREs were similar across different regions. The authors compared their method with the current surface registration methods that use only a part of the facial surface on the elastic phantom, and the mean TRE of 15 targets was 1.48 ± 0.21 mm and 1.98 ± 0.53 mm, respectively. In a clinical experiment, the mean TRE of seven targets on the patient's head surface was 1.92 ± 0.18 mm, which was sufficient to meet clinical requirements. The proposed surface-matching registration method provides sufficient registration accuracy even in the posterior area of the head. The 3D point cloud of the entire head, including the facial surface and the back of the head, can be easily acquired using a portable 3D scanner. The scanner does not need to be calibrated prior or tracked by the optical tracking system during scanning.

  8. An Adaptive Low-Cost GNSS/MEMS-IMU Tightly-Coupled Integration System with Aiding Measurement in a GNSS Signal-Challenged Environment.

    PubMed

    Zhou, Qifan; Zhang, Hai; Li, You; Li, Zheng

    2015-09-18

    The main aim of this paper is to develop a low-cost GNSS/MEMS-IMU tightly-coupled integration system with aiding information that can provide reliable position solutions when the GNSS signal is challenged such that less than four satellites are visible in a harsh environment. To achieve this goal, we introduce an adaptive tightly-coupled integration system with height and heading aiding (ATCA). This approach adopts a novel redundant measurement noise estimation method for an adaptive Kalman filter application and also augments external measurements in the filter to aid the position solutions, as well as uses different filters to deal with various situations. On the one hand, the adaptive Kalman filter makes use of the redundant measurement system's difference sequence to estimate and tune noise variance instead of employing a traditional innovation sequence to avoid coupling with the state vector error. On the other hand, this method uses the external height and heading angle as auxiliary references and establishes a model for the measurement equation in the filter. In the meantime, it also changes the effective filter online based on the number of tracked satellites. These measures have increasingly enhanced the position constraints and the system observability, improved the computational efficiency and have led to a good result. Both simulated and practical experiments have been carried out, and the results demonstrate that the proposed method is effective at limiting the system errors when there are less than four visible satellites, providing a satisfactory navigation solution.

  9. Using visuo-kinetic virtual reality to induce illusory spinal movement: the MoOVi Illusion

    PubMed Central

    Smith, Ross T.; Hunter, Estin V.; Davis, Miles G.; Sterling, Michele; Moseley, G. Lorimer

    2017-01-01

    Background Illusions that alter perception of the body provide novel opportunities to target brain-based contributions to problems such as persistent pain. One example of this, mirror therapy, uses vision to augment perceived movement of a painful limb to treat pain. Since mirrors can’t be used to induce augmented neck or other spinal movement, we aimed to test whether such an illusion could be achieved using virtual reality, in advance of testing its potential therapeutic benefit. We hypothesised that perceived head rotation would depend on visually suggested movement. Method In a within-subjects repeated measures experiment, 24 healthy volunteers performed neck movements to 50o of rotation, while a virtual reality system delivered corresponding visual feedback that was offset by a factor of 50%–200%—the Motor Offset Visual Illusion (MoOVi)—thus simulating more or less movement than that actually occurring. At 50o of real-world head rotation, participants pointed in the direction that they perceived they were facing. The discrepancy between actual and perceived direction was measured and compared between conditions. The impact of including multisensory (auditory and visual) feedback, the presence of a virtual body reference, and the use of 360o immersive virtual reality with and without three-dimensional properties, was also investigated. Results Perception of head movement was dependent on visual-kinaesthetic feedback (p = 0.001, partial eta squared = 0.17). That is, altered visual feedback caused a kinaesthetic drift in the direction of the visually suggested movement. The magnitude of the drift was not moderated by secondary variables such as the addition of illusory auditory feedback, the presence of a virtual body reference, or three-dimensionality of the scene. Discussion Virtual reality can be used to augment perceived movement and body position, such that one can perform a small movement, yet perceive a large one. The MoOVi technique tested here has clear potential for assessment and therapy of people with spinal pain. PMID:28243537

  10. Using visuo-kinetic virtual reality to induce illusory spinal movement: the MoOVi Illusion.

    PubMed

    Harvie, Daniel S; Smith, Ross T; Hunter, Estin V; Davis, Miles G; Sterling, Michele; Moseley, G Lorimer

    2017-01-01

    Illusions that alter perception of the body provide novel opportunities to target brain-based contributions to problems such as persistent pain. One example of this, mirror therapy, uses vision to augment perceived movement of a painful limb to treat pain. Since mirrors can't be used to induce augmented neck or other spinal movement, we aimed to test whether such an illusion could be achieved using virtual reality, in advance of testing its potential therapeutic benefit. We hypothesised that perceived head rotation would depend on visually suggested movement. In a within-subjects repeated measures experiment, 24 healthy volunteers performed neck movements to 50 o of rotation, while a virtual reality system delivered corresponding visual feedback that was offset by a factor of 50%-200%-the Motor Offset Visual Illusion (MoOVi)-thus simulating more or less movement than that actually occurring. At 50 o of real-world head rotation, participants pointed in the direction that they perceived they were facing. The discrepancy between actual and perceived direction was measured and compared between conditions. The impact of including multisensory (auditory and visual) feedback, the presence of a virtual body reference, and the use of 360 o immersive virtual reality with and without three-dimensional properties, was also investigated. Perception of head movement was dependent on visual-kinaesthetic feedback ( p  = 0.001, partial eta squared = 0.17). That is, altered visual feedback caused a kinaesthetic drift in the direction of the visually suggested movement. The magnitude of the drift was not moderated by secondary variables such as the addition of illusory auditory feedback, the presence of a virtual body reference, or three-dimensionality of the scene. Virtual reality can be used to augment perceived movement and body position, such that one can perform a small movement, yet perceive a large one. The MoOVi technique tested here has clear potential for assessment and therapy of people with spinal pain.

  11. Genetics Home Reference: PPP2R5D-related intellectual disability

    MedlinePlus

    ... and delayed speech development. Recurrent seizures (epilepsy) and autism spectrum disorder , which is characterized by impaired communications ... Increased Head Circumference Encyclopedia: Intellectual Disability Health Topic: Autism Spectrum ... Topic: Developmental Disabilities Additional NIH ...

  12. Reference Points: Engineering Technology Education Bibliography, 1987.

    ERIC Educational Resources Information Center

    Engineering Education, 1989

    1989-01-01

    Lists articles and books published in 1987. Selects the following headings: administration, aeronautical, architectural, CAD/CAM, civil, computers, curriculum, electrical/electronics, industrial, industry/government/employers, instructional technology, laboratories, liberal studies, manufacturing, mechanical, minorities, research, robotics,…

  13. Investing in Preschool.

    ERIC Educational Resources Information Center

    Bracey, Gerald W.

    2003-01-01

    Reviews several studies examining long-term academic, economic, and social benefits of investment in early childhood education. Includes the High/Scope Perry Preschool Project, the Chicago Child-Parent Center Program, the Abecedarian Project, and Head Start. (Contains 10 references.) (PKP)

  14. 46 CFR 154.1 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42nd Street, New York, NY 10036 ANSI Z89.1-69 Safety Requirements for Industrial Head Protection, 1969... Equipment of Ships Carrying Liquefied Gases in Bulk, 1976 Code For Existing Ships Carrying Liquefied Gases...

  15. Effectiveness of an oral health program in improving the knowledge and competencies of head start staff.

    PubMed

    Chinn, Courtney Hugh

    2011-01-01

    Head Start and Early Head Start (HS/EHS) programs have partnered with the American Academy of Pediatric Dentistry to promote oral health and increase access to dental homes. Preparing HS/EHS staff for issues related to pediatric oral health promises to improve effectiveness of this collaboration. This paper's purpose was to describe the Columbia Head Start Oral Health Program (C-HSOHP) and changes in HS/EHS staff pediatric oral health knowledge and competencies after participating in C-HSOHP. Four HS/EHS grantees in New York City engaged in the 2008-09 C-HSOHP. A convenience sample of 61 staff completed pre- and postself assessments of knowledge and competencies. Significant paired mean improvements were found for staff-reported level of preparation to explain dental issues during pregnancy, the tooth decay process, and preparing parents for their child's first dental visit. Significant improvements were found in staff confidence in teaching parents about children's oral health issues, referring for pediatric dental services, and talking to a dentist about a concern. The Columbia Head Start Oral Health Program was effective in improving Head Start/Early Head Start staff self-confidence and self-perceived preparedness in teaching parents about oral health, applying oral health knowledge to HS/EHS programs, communicating with dental professionals, and improving access to pediatric dental services.

  16. A 1-Diopter Vertical Prism Induces a Decrease of Head Rotation: A Pilot Investigation.

    PubMed

    Matheron, Eric; Zandi, Ava; Wang, Danping; Kapoula, Zoï

    2016-01-01

    Clinical studies in non-specific chronic arthralgia and back pain seem to indicate an association between vertical heterophoria (VH - latent vertical retinal misalignment) and asymmetrical head rotation. Such clinical observations suggest a link between VH and head rotation, but this was never tested. The purpose of this study was to simulate a VH in healthy subjects and examine its influence on the amplitude of active head rotation during 3D motion capture in upright stance. Subjects were asked to rotate their head three times from the straight ahead position and then to the right, back to straight ahead, to the left, and back to the straight ahead again. Three randomized conditions were run: normal viewing, with a 1-diopter prism base down on the dominant eye, or the non-dominant eye. The most important finding is that the experimental VH whichever the eye with the prism induces a significant decrease in the mean angle of head rotation compared to the normal viewing condition. This decrease was significant for rotation to the left. We suggest that the prism-induced VH modifies the reference posture and thereby affects head rotation; further studies are needed to confirm this effect and to extend to other types of dynamic activities.

  17. Latency Requirements for Head-Worn Display S/EVS Applications

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Trey Arthur, J. J., III; Williams, Steven P.

    2004-01-01

    NASA s Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas flight control, flight simulation, and virtual reality are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.

  18. Latency requirements for head-worn display S/EVS applications

    NASA Astrophysics Data System (ADS)

    Bailey, Randall E.; Arthur, Jarvis J., III; Williams, Steven P.

    2004-08-01

    NASA's Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas - flight control, flight simulation, and virtual reality - are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.

  19. RNA-seq analysis of the head-kidney transcriptome response to handling-stress in the red cusk-eel (Genypterus chilensis).

    PubMed

    Aballai, Víctor; Aedo, Jorge E; Maldonado, Jonathan; Bastias-Molina, Macarena; Silva, Herman; Meneses, Claudio; Boltaña, Sebastian; Reyes, Ariel; Molina, Alfredo; Valdés, Juan Antonio

    2017-12-01

    Stress is a primary contributing factor of fish disease and mortality in aquaculture. We have previously reported that the red cusk-eel (Genypterus chilensis), an important farmed marine fish, demonstrates a handling-stress response that results in increased juvenile mortality, which is mainly associated with skeletal muscle atrophy and liver steatosis. To better understand the systemic effects of stress on red cusk-eel immune-related gene expression, the present study assessed the transcriptomic head-kidney response to handling-stress. The RNA sequencing generated a total of 61,655,525 paired-end reads from control and stressed conditions. De novo assembly using the CLC Genomic Workbench produced 86,840 transcripts and created a reference transcriptome with a N50 of 1426bp. Reads mapped onto the assembled reference transcriptome resulted in the identification of 569 up-regulated and 513 down-regulated transcripts. Gene ontology enrichment analysis revealed a significant up-regulation of the biological processes, like response to stress, response to biotic stimulus, and immune response. Conversely, a significant down-regulation of biological processes is associated with metabolic processes. These results were validated by RT-qPCR analysis for nine candidate genes involved in the immune response. The present data demonstrated that short term stress promotes the immune innate response in the marine teleost G. chilensis. This study is an important step towards understanding the immune adaptive response to stress in non-model teleost species. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Reference Material for Health Auxiliaries and Their Teachers. Second Edition = Materiel de Reference Destine aux Auxiliaires Sanitaires et a Leurs Enseignants. Deuxieme Edition.

    ERIC Educational Resources Information Center

    World Health Organization, Geneva (Switzerland).

    This bibliography contains annotations of materials that could be used by health personnel and their teachers in developing countries. Over 600 entries are presented in French and in English sections. Each section consists of 13 subject headings, an author index, and a title index. The annotations describe the contents, level, and uses of the…

  1. Completed Research in Health, Physical Education, and Recreation. Including International Sources, Volume 19, 1977 Edition, Covering Research Completed in 1976.

    ERIC Educational Resources Information Center

    Thomas, Jerry R., Ed.; Weiss, Raymond A., Ed.

    This compilation lists research completed in the areas of health, physical education, recreation, and allied areas during 1976. It is arranged in three parts. (1) Index: In this section, cross references are given for all the listings in parts two and three. References are arranged under the subject headings, which are in alphabetical order. (2)…

  2. Simple and robust referencing system enables identification of dissolved-phase xenon spectral frequencies.

    PubMed

    Antonacci, Michael A; Zhang, Le; Burant, Alex; McCallister, Drew; Branca, Rosa T

    2018-08-01

    To assess the effect of macroscopic susceptibility gradients on the gas-phase referenced dissolved-phase 129 Xe (DPXe) chemical shift (CS) and to establish the robustness of a water-based referencing system for in vivo DPXe spectra. Frequency shifts induced by spatially varying magnetic susceptibility are calculated by finite-element analysis for the human head and chest. Their effect on traditional gas-phase referenced DPXe CS is then assessed theoretically and experimentally. A water-based referencing system for the DPXe resonances that uses the local water protons as reference is proposed and demonstrated in vivo in rats. Across the human brain, macroscopic susceptibility gradients can induce an apparent variation in the DPXe CS of up to 2.5 ppm. An additional frequency shift as large as 6.5 ppm can exist between DPXe and gas-phase resonances. By using nearby water protons as reference for the DPXe CS, the effect of macroscopic susceptibility gradients is eliminated and consistent CS values are obtained in vivo, regardless of shimming conditions, region of interest analyzed, animal orientation, or lung inflation. Combining in vitro and in vivo spectroscopic measurements finally enables confident assignment of some of the DPXe peaks observed in vivo. To use hyperpolarized xenon as a biological probe in tissues, the DPXe CS in specific organs/tissues must be reliably measured. When the gas-phase is used as reference, variable CS values are obtained for DPXe resonances. Reliable peak assignments in DPXe spectra can be obtained by using local water protons as reference. Magn Reson Med 80:431-441, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Development of an Inflatable Head/Neck Restraint System for Ejection Seats (Update)

    DTIC Science & Technology

    1978-12-19

    REPORT NO. NADC-78213-60 DEVELOPMENT OF AN INFLATABLE HEAD /NECK RESTRAINT SYSTEM FOR EJECTION SEATS (UPD ATE) Thomas J. Zenobi Aircraft and Crew...olde if necsesey anid dentlif hr bl0ck ma11,0s.) t Inflatable neck collar Inflatable neck ring Neck injury Head rotation ý2 .AeSSRACT (Continus on...toenes side It nec~essary mod identl)_* by block naob..) F1 A ring-shaped inflatable head /neck restraint system for ejection seats is be- ing developed at

  4. A Robust H ∞ Controller for an UAV Flight Control System

    PubMed Central

    López, J.

    2015-01-01

    The objective of this paper is the implementation and validation of a robust H ∞ controller for an UAV to track all types of manoeuvres in the presence of noisy environment. A robust inner-outer loop strategy is implemented. To design the H ∞ robust controller in the inner loop, H ∞ control methodology is used. The two controllers that conform the outer loop are designed using the H ∞ Loop Shaping technique. The reference vector used in the control architecture formed by vertical velocity, true airspeed, and heading angle, suggests a nontraditional way to pilot the aircraft. The simulation results show that the proposed control scheme works well despite the presence of noise and uncertainties, so the control system satisfies the requirements. PMID:26221622

  5. SU-E-T-32: A Feasibility Study of Independent Dose Verification for IMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamima, T; Takahashi, R; Sato, Y

    2015-06-15

    Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose calculation software program (Simple MU Analysis, Triangle Products, JP) was used in this study, which can compute the radiological path length from the surface to the reference point for each control point using patient’s CT image dataset and the MLC aperture shape was simultaneously modeled in reference to the information of MLC from DICOM-RT plan. Dose calculation was performed using a modified Clarkson method considering MLC transmission and dosimetric leaf gap. In this study, a retrospective analysis was conductedmore » in which IMAT plans from 120 patients of the two sites (prostate / head and neck) from four institutes were retrospectively analyzed to compare the Indp to the TPS using patient CT images. In addition, an ion-chamber measurement was performed to verify the accuracy of the TPS and the Indp in water-equivalent phantom. Results: The agreements between the Indp and the TPS (mean±1SD) were −0.8±2.4% and −1.3±3.8% for the regions of prostate and head and neck, respectively. The measurement comparison showed similar results (−0.8±1.6% and 0.1±4.6% for prostate and head and neck). The variation was larger in the head and neck because the number of the segments was increased that the reference point was under the MLC and the modified Clarkson method cannot consider the smooth falloff of the leaf penumbra. Conclusion: The independent verification program would be practical and effective for secondary check for IMAT with the sufficient accuracy in the measurement and CT-based calculation. The accuracy would be improved if considering the falloff of the leaf penumbra.« less

  6. JackIn Head: Immersive Visual Telepresence System with Omnidirectional Wearable Camera.

    PubMed

    Kasahara, Shunichi; Nagai, Shohei; Rekimoto, Jun

    2017-03-01

    Sharing one's own immersive experience over the Internet is one of the ultimate goals of telepresence technology. In this paper, we present JackIn Head, a visual telepresence system featuring an omnidirectional wearable camera with image motion stabilization. Spherical omnidirectional video footage taken around the head of a local user is stabilized and then broadcast to others, allowing remote users to explore the immersive visual environment independently of the local user's head direction. We describe the system design of JackIn Head and report the evaluation results of real-time image stabilization and alleviation of cybersickness. Then, through an exploratory observation study, we investigate how individuals can remotely interact, communicate with, and assist each other with our system. We report our observation and analysis of inter-personal communication, demonstrating the effectiveness of our system in augmenting remote collaboration.

  7. Head Start and Urban Children’s School Readiness: A Birth Cohort Study in 18 Cities

    PubMed Central

    Zhai, Fuhua; Brooks-Gunn, Jeanne; Waldfogel, Jane

    2011-01-01

    We used longitudinal data from a birth cohort study, the Fragile Families and Child Wellbeing Study, to investigate the links between Head Start and school readiness in a large and diverse sample of urban children at age 5 (N = 2,803; 18 cities). We found that Head Start attendance was associated with enhanced cognitive ability and social competence and reduced attention problems but not reduced internalizing or externalizing behavior problems. These findings were robust to model specifications (including models with city-fixed effects and propensity-scoring matching). Furthermore, the effects of Head Start varied by the reference group. Head Start was associated with improved cognitive development when compared with parental care or other nonparental care, as well as improved social competence (compared with parental care) and reduced attention problems (compared with other nonparental care). In contrast, compared with attendance at pre-kindergarten or other center-based care, Head Start attendance was not associated with cognitive gains but with improved social competence and reduced attention and externalizing behavior problems (compared with attendance at other center-based care). These associations were not moderated by child gender or race/ethnicity. PMID:21244155

  8. Head Start and urban children's school readiness: a birth cohort study in 18 cities.

    PubMed

    Zhai, Fuhua; Brooks-Gunn, Jeanne; Waldfogel, Jane

    2011-01-01

    We used longitudinal data from a birth cohort study, the Fragile Families and Child Wellbeing Study, to investigate the links between Head Start and school readiness in a large and diverse sample of urban children at age 5 (N = 2,803; 18 cities). We found that Head Start attendance was associated with enhanced cognitive ability and social competence and reduced attention problems but not reduced internalizing or externalizing behavior problems. These findings were robust to model specifications (including models with city-fixed effects and propensity-scoring matching). Furthermore, the effects of Head Start varied by the reference group. Head Start was associated with improved cognitive development when compared with parental care or other nonparental care, as well as improved social competence (compared with parental care) and reduced attention problems (compared with other nonparental care). In contrast, compared with attendance at pre-kindergarten or other center-based care, Head Start attendance was not associated with cognitive gains but with improved social competence and reduced attention and externalizing behavior problems (compared with attendance at other center-based care). These associations were not moderated by child gender or race/ethnicity.

  9. Assessment of nutritional status and quality of life in patients treated for head and neck cancer.

    PubMed

    Prevost, V; Joubert, C; Heutte, N; Babin, E

    2014-04-01

    The purpose of this study was to identify tools for the assessment of nutritional status in head and neck cancer patients, to evaluate the impact of malnutrition on therapeutic management and quality of life and to propose a simple screening approach adapted to routine clinical practice. The authors conducted a review of the literature to identify tools for the assessment of nutritional status in head and neck cancer patients published in French and English. Articles were obtained from the PubMed database and from the references of these articles and selected journals, using the keywords: "nutritional assessment", and "head and neck" and "cancer". Anthropometric indices, laboratory parameters, dietary intake assessment, clinical scores and nutritional risk scores used in patients with head and neck cancers are presented. The relevance of these tools in clinical practice and in research is discussed, together with the links between nutritional status and quality of life. This article is designed to help teams involved in the management of patients with head and neck cancer to choose the most appropriate tools for assessment of nutritional status according to their resources and their objectives. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  10. Penetrating head injury from angle grinder: A cautionary tale.

    PubMed

    Senthilkumaran, S; Balamurgan, N; Arthanari, K; Thirumalaikolundusubramanian, P

    2010-01-01

    Penetrating cranial injury is a potentially life-threatening condition. Injuries resulting from the use of angle grinders are numerous and cause high-velocity penetrating cranial injuries. We present a series of two penetrating head injuries associated with improper use of angle grinder, which resulted in shattering of disc into high velocity missiles with reference to management and prevention. One of those hit on the forehead of the operator and the other on the occipital region of the co-worker at a distance of five meters. The pathophysiological consequence of penetrating head injuries depends on the kinetic energy and trajectory of the object. In the nearby healthcare center the impacted broken disc was removed without realising the consequences and the wound was packed. As the conscious level declined in both, they were referred. CT brain revealed fracture in skull and changes in the brain in both. Expeditious removal of the penetrating foreign body and focal debridement of the scalp, skull, dura, and involved parenchyma and Watertight dural closure were carried out. The most important thing is not to remove the impacted foreign body at the site of accident. Craniectomy around the foreign body, debridement and removal of foreign body without zigzag motion are needed. Removal should be done following original direction of projectile injury. The neurological sequelae following the non missile penetrating head injuries are determined by the severity and location of initial injury as well as the rapidity of the exploration and fastidious debridement.

  11. Clinical value of 18 FDG PET/CT in screening for distant metastases in head and neck squamous cell carcinoma.

    PubMed

    Deurvorst, S E; Hoekstra, O S; Castelijns, J A; Witte, B I; Leemans, C R; de Bree, R

    2018-06-01

    The detection of distant metastases is of major importance in management of head and neck squamous cell carcinoma patients. All patients underwent 18 FDG PET/CT for the detection of distant metastases. Retrospective single-centre study. Head and neck squamous cell carcinoma patients with high-risk factors for distant metastases. Accuracy of 18 FDG PET/CT for the detection of distant metastases using clinical development of distant metastases and a minimal follow-up of twelve months as reference standard. Comparison of overall survival between patients diagnosed with distant metastases during initial screening and patients diagnosed with distant metastases during follow-up. In 23 (12%) of the 190 patients, 18 FDG PET/CT detected distant metastases at screening. Sensitivity and negative predictive value were 46.2% (95% CI 32.6-59.7) and 82.6% (95% CI 76.8-88.5). No difference in median overall survival from the time of distant metastases detection was found between patients diagnosed with DM during work-up or during follow-up. In head and neck squamous cell carcinoma patients with high-risk factors, 18 FDG PET/CT has a high negative predictive value for the detection of distant metastases and should be used in daily clinical practice, although the sensitivity is limited when long-term follow-up is used as reference standard. © 2018 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.

  12. Multispectral image-fused head-tracked vision system (HTVS) for driving applications

    NASA Astrophysics Data System (ADS)

    Reese, Colin E.; Bender, Edward J.

    2001-08-01

    Current military thermal driver vision systems consist of a single Long Wave Infrared (LWIR) sensor mounted on a manually operated gimbal, which is normally locked forward during driving. The sensor video imagery is presented on a large area flat panel display for direct view. The Night Vision and Electronics Sensors Directorate and Kaiser Electronics are cooperatively working to develop a driver's Head Tracked Vision System (HTVS) which directs dual waveband sensors in a more natural head-slewed imaging mode. The HTVS consists of LWIR and image intensified sensors, a high-speed gimbal, a head mounted display, and a head tracker. The first prototype systems have been delivered and have undergone preliminary field trials to characterize the operational benefits of a head tracked sensor system for tactical military ground applications. This investigation will address the advantages of head tracked vs. fixed sensor systems regarding peripheral sightings of threats, road hazards, and nearby vehicles. An additional thrust will investigate the degree to which additive (A+B) fusion of LWIR and image intensified sensors enhances overall driving performance. Typically, LWIR sensors are better for detecting threats, while image intensified sensors provide more natural scene cues, such as shadows and texture. This investigation will examine the degree to which the fusion of these two sensors enhances the driver's overall situational awareness.

  13. Galectins and Carcinogenesis: Their Role in Head and Neck Carcinomas and Thyroid Carcinomas.

    PubMed

    Kindt, Nadège; Journe, Fabrice; Ghanem, Ghanem E; Saussez, Sven

    2017-12-18

    Head and neck cancers are among the most frequently occurring cancers worldwide. Of the molecular drivers described for these tumors, galectins play an important role via their interaction with several intracellular pathways. In this review, we will detail and discuss this role with specific reference to galectins-1, -3, and -7 in angiogenesis, cell proliferation, and invasion as well as in cell transformation and cancer progression. Furthermore, we will evaluate the prognostic value of galectin expression in head and neck cancers including those with oral cavity, salivary gland, and nasopharyngeal pathologies. In addition, we will discuss the involvement of these galectins in thyroid cancers where their altered expression is proposed as a new diagnostic biomarker.

  14. Stabilization and mobility of the head, neck and trunk in horses during overground locomotion: comparisons with humans and other primates.

    PubMed

    Dunbar, Donald C; Macpherson, Jane M; Simmons, Roger W; Zarcades, Athina

    2008-12-01

    Segmental kinematics were investigated in horses during overground locomotion and compared with published reports on humans and other primates to determine the impact of a large neck on rotational mobility (> 20 deg.) and stability (< or = 20 deg.) of the head and trunk. Three adult horses (Equus caballus) performing walks, trots and canters were videotaped in lateral view. Data analysis included locomotor velocity, segmental positions, pitch and linear displacements and velocities, and head displacement frequencies. Equine, human and monkey skulls and cervical spines were measured to estimate eye and vestibular arc length during head pitch displacements. Horses stabilized all three segments in all planes during all three gaits, unlike monkeys and humans who make large head pitch and yaw rotations during walks, and monkeys that make large trunk pitch rotations during gallops. Equine head angular displacements and velocities, with some exceptions during walks, were smaller than in humans and other primates. Nevertheless, owing to greater off-axis distances, orbital and vestibular arc lengths remained larger in horses, with the exception of head-neck axial pitch during trots, in which equine arc lengths were smaller than in running humans. Unlike monkeys and humans, equine head peak-frequency ranges fell within the estimated range in which inertia has a compensatory stabilizing effect. This inertial effect was typically over-ridden, however, by muscular or ligamentous intervention. Thus, equine head pitch was not consistently compensatory, as reported in humans. The equine neck isolated the head from the trunk enabling both segments to provide a spatial reference frame.

  15. A set of constitutive relationships accounting for residual NAPL in the unsaturated zone.

    PubMed

    Wipfler, E L; van der Zee, S E

    2001-07-01

    Although laboratory experiments show that non-aqueous phase liquid (NAPL) is retained in the unsaturated zone, no existing multiphase flow model has been developed to account for residual NAPL after NAPL drainage in the unsaturated zone. We developed a static constitutive set of saturation-capillary pressure relationships for water, NAPL and air that accounts for both this residual NAPL and entrapped NAPL. The set of constitutive relationships is formulated similarly to the set of scaled relationships that is frequently applied in continuum models. The new set consists of three fluid-phase systems: a three-phase system and a two-phase system, that both comply with the original constitutive model, and a newly introduced residual NAPL system. The new system can be added relatively easily to the original two- and three-phase systems. Entrapment is included in the model. The constitutive relationships of the non-drainable residual NAPL system are based on qualitative fluid behavior derived from a pore scale model. The pore scale model reveals that the amount of residual NAPL depends on the spreading coefficient and the water saturation. Furthermore, residual NAPL is history-dependent. At the continuum scale, a critical NAPL pressure head defines the transition from free, mobile NAPL to residual NAPL. Although the Pc-S relationships for water and total liquid are not independent in case of residual NAPL, two two-phase Pc-S relations can represent a three-phase residual system of Pc-S relations. A newly introduced parameter, referred to as the residual oil pressure head, reflects the mutual dependency of water and oil. Example calculations show consistent behavior of the constitutive model. Entrapment and retention in the unsaturated zone cooperate to retain NAPL. Moreover, the results of our constitutive model are in agreement with experimental observations.

  16. First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    NASA Astrophysics Data System (ADS)

    Sportelli, G.; Belcari, N.; Camarlinghi, N.; Cirrone, G. A. P.; Cuttone, G.; Ferretti, S.; Kraan, A.; Ortuño, J. E.; Romano, F.; Santos, A.; Straub, K.; Tramontana, A.; Del Guerra, A.; Rosso, V.

    2014-01-01

    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1 mm when at least 5 Gy are delivered.

  17. New head exposure system for use in human provocation studies with EEG recording during GSM900- and UMTS-like exposure.

    PubMed

    Schmid, Gernot; Cecil, Stefan; Goger, Christoph; Trimmel, Michael; Kuster, Niels; Molla-Djafari, Hamid

    2007-12-01

    A new head exposure system for double blinded human provocation studies, which requires EEG recording during exposure with GSM900- and UMTS-like signals has been developed and dosimetrically evaluated. The system uses planar patch antennas fixed at 65 mm distance from the subject's head by a special headset, which provides minimum impairment of the test subjects and ensures an almost constant position of the antennas with respect to the head, even in case of head movements. Compared to exposure concepts operating small antennas in close proximity to the head, the concept of planar antennas at a certain distance from the head produces a much more homogeneous SAR distribution in the temporal and parietal lobe of the brain. At the same time the resulting uncertainty of exposure due to variations in head size, variations of the dielectric properties of tissues and unavoidable small changes of the antenna's position with respect to the head, is reduced to the order of approximately 3 dB, which is a significant improvement to comparable head exposure systems reported in literature in the past. To avoid electromagnetic interference on the EEG recording caused by the incident RF-field an appropriate double-shielded filter circuit has been developed. Furthermore, the effect of the presence of the sintered Ag/AgCl EEG electrodes and electrode wires on the SAR distribution inside the head has been investigated and was found to be minimal if the electrode wires are arranged orthogonal to the incident electric field vector. EEG electrode arrangement parallel to the incident field vector, however, might cause drastic changes in the SAR distribution inside the head. (c) 2007 Wiley-Liss, Inc.

  18. Percutaneous Endoscopic Gastrostomy Tube Is a Negative Prognostic Factor for Recurrent/Metastatic Head and Neck Cancer.

    PubMed

    Siano, Marco; Jarisch, Nadine; Joerger, Markus; Espeli, Vittoria

    2018-06-01

    Recurrent/metastatic head and neck squamous cell cancer (r/mHNSCC) patients often need a percutaneous endoscopic gastrostomy feeding tube (PEG). Among known prognostic factors, PEG could be prognostic as well. We retrospectively analyzed r/mHNSCC patients referred for systemic treatment. Kaplan-Meier and multivariate cox regression models were applied to assess prognostic impact of PEG. One hunderd and ten patients were identified, 42 had a PEG at treatment start. Median survival from start of 1st-line systemic treatment was 8 months (95%CI=6.5-12.0 months), 4.5 months (95%CI=2.5-7.0 months) for patients with PEG and 11.5 months (95%CI=7.5-14.5 months) without PEG (adjusted HR=1.98, p=0.011). Similarly, survival from first recurrence of distant metastases was lower in patients with PEG as compared to patients without (7.5 vs. 15.5 months, adjusted HR=2.60, p<0.001). Presence of PEG feeding tube has an unfavourable prognostic impact on survival in patients with r/mHNSCC. While any causality remains speculative, potential complications should be appreciated before PEG implantation. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  19. Women's History Bibliography.

    ERIC Educational Resources Information Center

    Bonifanti, Georgeanne

    Over 150 resources on women's history are arranged under the following headings: author/title, collective biographies, reference materials, and individual biographies. Within the biography categories, publications are arranged alphabetically by author (collective biographies) or subject (individual biographies). Within the remaining categories,…

  20. Genetics Home Reference: Pelizaeus-Merzbacher-like disease type 1

    MedlinePlus

    ... scale (dysmetria), tremors that occur mainly during movement (intention tremors), and head and neck tremors (titubation). People ... Available from http://www.ncbi.nlm.nih.gov/books/NBK470716/ Citation on PubMed Orthmann-Murphy JL, Freidin ...

  1. Effect of nitrogen fertilisation on the overall quality of minimally processed globe artichoke heads.

    PubMed

    Lombardo, Sara; Restuccia, Cristina; Muratore, Giuseppe; Barbagallo, Riccardo N; Licciardello, Fabio; Pandino, Gaetano; Scifò, Giovanna O; Mazzaglia, Agata; Ragonese, Francesca; Mauromicale, Giovanni

    2017-01-01

    Although nitrogen (N) fertilisation is essential for promoting crop yield, it may also affect the produce quality. Here, the influence of three N fertiliser rates (0 kg ha -1 as a control, 200 kg ha -1 and 400 kg ha -1 referred to as N 0 , N 200 and N 400 , respectively) on the overall quality of minimally processed globe artichoke heads was investigated during refrigerated storage for 12 days. Throughout the storage time, N fertilised samples had higher inulin contents than those unfertilised. In addition, the respiratory quotient of N 200 and N 400 samples was 2-fold and 2.5-fold lower than N 0 ones, whose values were close to the normal range for vegetables. All the samples reported good microbiological standards, although N 200 and N 400 achieved lower mesophilic and psychotropic counts than N 0 throughout the storage time. After 8 and 12 days of refrigerated storage, the N 200 samples showed the highest scores of positive sensory descriptors. A fertiliser level of 200 kg N ha -1 is suitable for obtaining minimally processed globe artichoke heads with good nutritional, sensory and microbiological quality, characterised by low endogenous oxidase activities. Proper packaging systems and procedures are, however, crucial for extending the product shelf-life and, thus, promoting its exportation on a wider scale. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  2. SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogunmolu, O; Gans, N; Jiang, S

    Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance ofmore » the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.« less

  3. Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

    PubMed

    Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T

    2017-12-01

    The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.

  4. Assessment of a head support system to prevent pediatric out-of-position: an observational study.

    PubMed

    Lopez-Valdes, Francisco J; Forman, Jason L; Ash, Joseph H; Kent, Richard; Alba, Juan J; Segui-Gomez, Maria

    Head injuries are the most common severe injuries sustained by pediatric occupants in road traffic crashes. Preventing children from adopting positions that can result in an increased injury risk due to unfavorable interactions with the restraints is fundamental. The objective of this paper was to assess the effect of a head support system (SS) on the lateral position of the head, the vertical position of the sternum and the shoulder belt fit. Thirty pediatric rear-seat passengers were exposed to two 75-minute trials. Volunteers were restrained by a three-point belt and, if needed, used the appropriate child restraint system for their anthropometry (high-back booster, low-back booster, no booster). A case crossover study was designed in which the volunteers used the head support system (SS) during one of the trials, acting as their own controls (No SS) in the other. Compared to the control group, the head support reduced significantly the 90(th) percentile value of the absolute value of the relative lateral motion of the head, regardless of the restraint used. The system also reduced the maximum downward position of the sternal notch within the low-back booster group. As for the belt fit, the use of the head support improved significantly the position of the shoulder belt on the occupant in the low-back booster and in the no booster groups.

  5. Assessment of a head support system to prevent pediatric out-of-position: an observational study

    PubMed Central

    Lopez-Valdes, Francisco J.; Forman, Jason L.; Ash, Joseph H.; Kent, Richard; Alba, Juan J.; Segui-Gomez, Maria

    2013-01-01

    Head injuries are the most common severe injuries sustained by pediatric occupants in road traffic crashes. Preventing children from adopting positions that can result in an increased injury risk due to unfavorable interactions with the restraints is fundamental. The objective of this paper was to assess the effect of a head support system (SS) on the lateral position of the head, the vertical position of the sternum and the shoulder belt fit. Thirty pediatric rear-seat passengers were exposed to two 75-minute trials. Volunteers were restrained by a three-point belt and, if needed, used the appropriate child restraint system for their anthropometry (high-back booster, low-back booster, no booster). A case crossover study was designed in which the volunteers used the head support system (SS) during one of the trials, acting as their own controls (No SS) in the other. Compared to the control group, the head support reduced significantly the 90th percentile value of the absolute value of the relative lateral motion of the head, regardless of the restraint used. The system also reduced the maximum downward position of the sternal notch within the low-back booster group. As for the belt fit, the use of the head support improved significantly the position of the shoulder belt on the occupant in the low-back booster and in the no booster groups. PMID:24406966

  6. [Penetrating injuries in the face and neck region. Diagnosis and treatment].

    PubMed

    Maier, H; Tisch, M; Lorenz, K J; Danz, B; Schramm, A

    2011-08-01

    Penetrating head and neck injuries often present with vascular lesions and airway compromise and may be life-threatening. Thus controlling bleeding and airway stabilisation take priority in emergency treatment. High-velocity projectiles, fragmentations from improvised explosive devices (IEDs) and shrapnel can cause severe tissue injury, representing a challenge for the head and neck surgeon. Since several organ structures, such as the eyes, midface, pharynx, larynx, trachea, esophagus, nerves, vessels and vertebral spine can be injured at the same time, patients should be referred to a specialized trauma center for interdisciplinary treatment following emergency treatment. High-speed ballistic injuries were once confined to the battle field and have been uncommon in Europe since World War II. For this reason, experience among civilian head and neck surgeons is at present limited. With the increased incidence of terrorism and the use of IEDs as the preferred weapon in terrorism it has become important for civilian head and neck surgeons to understand the role of ballistic injuries in mass casualty events. The present paper discusses current viewpoints in the diagnosis and treatment of penetrating head and neck injuries.

  7. Dental consultation in patients planned for/undergoing/post radiation therapy for head and neck cancers: a questionnaire-based survey.

    PubMed

    Mainali, Apeksha; Sumanth, K N; Ongole, Ravikiran; Denny, Ceena

    2011-01-01

    Mouth and pharyngeal cancers account for approximately 6% of cancers worldwide. Radiotherapy is one of the means of treatment of head and neck cancer. Consultation with a dental team experienced in caring for patients undergoing treatment for head and neck cancer will improve the quality of life of such patients. To evaluate the attitude of oncologists toward dental consultation to patients planning for/prior to/undergoing/post radiation therapy for head and neck cancers and to evaluate the number of radiation oncologists who encounter oral complaints and consider worth referring to a dentist. A questionnaire-based study was carried out following mailing of covering letter and self-administered questionnaire comprising 11 items, to 25 radiation oncology centers selected in India based on convenient sampling. Out of the 25 centers, we received response from 20 centers with 60 completely filled questionnaires. Five centers did not respond for further correspondences. The study indicated a need for awareness and education among radiation oncologists regarding dental consultation in patients planned/undergoing /post radiation therapy for head and neck cancer.

  8. Methods for Expanding Rotary Wing Aircraft Health and Usage Monitoring Systems to the Rotating Frame through Real-time Rotor Blade Kinematics Estimation

    NASA Astrophysics Data System (ADS)

    Allred, Charles Jefferson

    Since the advent of Health and Usage Monitoring Systems (HUMS) in the early 1990's, there has been a steady decrease in the number of component failure related helicopter accidents. Additionally, measurable cost benefits due to improved maintenance practices based on HUMS data has led to a desire to expand HUMS from its traditional area of helicopter drive train monitoring. One of the areas of greatest interest for this expansion of HUMS is monitoring of the helicopter rotor head loads. Studies of rotor head load and blade motions have primarily focused on wind tunnel testing with technology which would not be applicable for production helicopter HUMS deployment, or measuring bending along the blade, rather than where it is attached to the rotor head and the location through which all the helicopter loads pass. This dissertation details research into finding methods for real time methods of estimating rotor blade motion which could be applied across helicopter fleets as an expansion of current HUMS technology. First, there is a brief exploration of supporting technologies which will be crucial in enabling the expansion of HUMS from the fuselage of helicopters to the rotor head: wireless data transmission and energy harvesting. A brief overview of the commercially available low power wireless technology selected for this research is presented. The development of a relatively high-powered energy harvester specific to the motion of helicopter rotor blades is presented and two different prototypes of the device are shown. Following the overview of supporting technologies, two novel methods of monitoring rotor blade motion in real time are developed. The first method employs linear displacement sensors embedded in the elastomer layers of a high-capacity laminate bearing of the type commonly used in fully articulated rotors throughout the helicopter industry. The configuration of these displacement sensors allows modeling of the sensing system as a robotic parallel mechanism, similar to a Stewart Platform. A calibration method for this device is developed and the improved orientation estimation results are shown. The second method is not specific to the fully articulated rotor head mounting geometry of the first method. Rather, it utilizes micro-electromechanical (MEMS) accelerometers and gyroscopes configured to measure the centrifugal acceleration and rotation rate induced through rotor head rotation differentially. By measuring these quantities differentially, other accelerations from the fuselage reference frame are removed from the measurement, resulting in acceleration and rate quantities that are impacted only by the angle of the sensors relative to the plane of rotation. By mounting these sensors strategically and symmetrically about the rotor blade root center of rotation, the orientation of the rotor blade can be estimated in real time.

  9. Evaluation of a video-based head motion tracking system for dedicated brain PET

    NASA Astrophysics Data System (ADS)

    Anishchenko, S.; Beylin, D.; Stepanov, P.; Stepanov, A.; Weinberg, I. N.; Schaeffer, S.; Zavarzin, V.; Shaposhnikov, D.; Smith, M. F.

    2015-03-01

    Unintentional head motion during Positron Emission Tomography (PET) data acquisition can degrade PET image quality and lead to artifacts. Poor patient compliance, head tremor, and coughing are examples of movement sources. Head motion due to patient non-compliance can be an issue with the rise of amyloid brain PET in dementia patients. To preserve PET image resolution and quantitative accuracy, head motion can be tracked and corrected in the image reconstruction algorithm. While fiducial markers can be used, a contactless approach is preferable. A video-based head motion tracking system for a dedicated portable brain PET scanner was developed. Four wide-angle cameras organized in two stereo pairs are used for capturing video of the patient's head during the PET data acquisition. Facial points are automatically tracked and used to determine the six degree of freedom head pose as a function of time. The presented work evaluated the newly designed tracking system using a head phantom and a moving American College of Radiology (ACR) phantom. The mean video-tracking error was 0.99±0.90 mm relative to the magnetic tracking device used as ground truth. Qualitative evaluation with the ACR phantom shows the advantage of the motion tracking application. The developed system is able to perform tracking with accuracy close to millimeter and can help to preserve resolution of brain PET images in presence of movements.

  10. A Morlet wavelet signal analysis with a Daubechies filter for the wear assessment of hip prostheses coated with diamond-like carbon by triboadhesion.

    PubMed

    Rodríguez-Lelis, Jose Maria; Mata, Dagoberto Tolosa; Vargas-Treviño, Marciano; Navarro-Torres, Jose; Piña-Piña, Gilberto; Abundez-Pliego, Arturo

    2010-08-01

    In the present work, based on high frequency wavelet analysis of dynamic signals of mechanical systems, a multiple-resolution wavelet analysis is carried out, to the signal obtained from an accelerometer mounted on the structure of a hip prosthesis wearing test device. The prostheses employed had a femoral head made of aluminum oxide and the acetabular cup of ultra-high-molecular-weight polyethylene. The first two aluminum oxide femoral heads were coated with diamond-like carbon and a third one was tested without coating and used as a reference. The coating was carried out by triboadhesion. Tests results showed that maximum vibration amplitude reached after 32 hr for the coated prostheses was 0.2 g. The noncoated prosthesis amplitude presented was 0.75 g in the same time interval. These values were attributed to wear damage on the surface of the prostheses, indicating that thin film DLC coating caused an increase of stiffness on the surface and therefore an increase in wear resistance approximately of 314%.

  11. Modeling and Simulation of Hydropower Station Diversion System's characteristic line method by introducing water head to flow feedback

    NASA Astrophysics Data System (ADS)

    Guangwen, Xu; Xi, Li; Ze, Yao

    2018-06-01

    To solve the damping problem of water hammer wave in the modeling method of water diversion system of hydropower station, this paper introduces the feedback regulation technology from head to flow, that is: A fixed water head is taken out for flow feedback, and the following conclusions are obtained through modeling and simulation. Adjusting the feedback coefficient F of the water head to the flow rate can change the damping characteristic of the system, which can simulate the attenuation process of the water shock wave in the true water diversion pipeline. Even if a small feedback coefficient is introduced, the damping effect of the system is very obvious, but it has little effect on the amplitude of the first water shock wave after the transition process. Therefore, it is feasible and reasonable to introduce water head to flow rate feedback coefficient F in hydraulic turbine diversion system.

  12. EnEx-RANGE - Robust autonomous Acoustic Navigation in Glacial icE

    NASA Astrophysics Data System (ADS)

    Heinen, Dirk; Eliseev, Dmitry; Henke, Christoph; Jeschke, Sabina; Linder, Peter; Reuter, Sebastian; Schönitz, Sebastian; Scholz, Franziska; Weinstock, Lars Steffen; Wickmann, Stefan; Wiebusch, Christopher; Zierke, Simon

    2017-03-01

    Within the Enceladus Explorer Initiative of the DLR Space Administration navigation technologies for a future space mission are in development. Those technologies are the basis for the search for extraterrestrial life on the Saturn moon Enceladus. An autonomous melting probe, the EnEx probe, aims to extract a liquid sample from a water reservoir below the icy crust. A first EnEx probe was developed and demonstrated in a terrestrial scenario at the Bloodfalls, Taylor Glacier, Antarctica in November 2014. To enable navigation in glacier ice two acoustic systems were integrated into the probe in addition to conventional navigation technologies. The first acoustic system determines the position of the probe during the run based on propagation times of acoustic signals from emitters at reference positions at the glacier surface to receivers in the probe. The second system provides information about the forefield of the probe. It is based on sonographic principles with phased array technology integrated in the probe's melting head. Information about obstacles or sampling regions in the probe's forefield can be acquired. The development of both systems is now continued in the project EnEx-RANGE. The emitters of the localization system are replaced by a network of intelligent acoustic enabled melting probes. These localize each other by means of acoustic signals and create the reference system for the EnEx probe. This presentation includes the discussion of the intelligent acoustic network, the acoustic navigation systems of the EnEx probe and results of terrestrial tests.

  13. An Adaptive Low-Cost GNSS/MEMS-IMU Tightly-Coupled Integration System with Aiding Measurement in a GNSS Signal-Challenged Environment

    PubMed Central

    Zhou, Qifan; Zhang, Hai; Li, You; Li, Zheng

    2015-01-01

    The main aim of this paper is to develop a low-cost GNSS/MEMS-IMU tightly-coupled integration system with aiding information that can provide reliable position solutions when the GNSS signal is challenged such that less than four satellites are visible in a harsh environment. To achieve this goal, we introduce an adaptive tightly-coupled integration system with height and heading aiding (ATCA). This approach adopts a novel redundant measurement noise estimation method for an adaptive Kalman filter application and also augments external measurements in the filter to aid the position solutions, as well as uses different filters to deal with various situations. On the one hand, the adaptive Kalman filter makes use of the redundant measurement system’s difference sequence to estimate and tune noise variance instead of employing a traditional innovation sequence to avoid coupling with the state vector error. On the other hand, this method uses the external height and heading angle as auxiliary references and establishes a model for the measurement equation in the filter. In the meantime, it also changes the effective filter online based on the number of tracked satellites. These measures have increasingly enhanced the position constraints and the system observability, improved the computational efficiency and have led to a good result. Both simulated and practical experiments have been carried out, and the results demonstrate that the proposed method is effective at limiting the system errors when there are less than four visible satellites, providing a satisfactory navigation solution. PMID:26393605

  14. Automated gantry-type stitching system

    NASA Technical Reports Server (NTRS)

    Thrash, Patrick J. (Inventor); Miller, Jeffrey L. (Inventor); Pallas, Kenneth G. (Inventor); Trank, Robert C. (Inventor); Fox, Rhoda (Inventor); Korte, Mike (Inventor); Codos, Richard (Inventor); Korolev, Aleksandr (Inventor); Collan, William (Inventor)

    1999-01-01

    A stitching system includes a gantry that is movable along a material support table. Mounted to the gantry are a plurality of stitching heads and bobbins. The stitching heads are individually controllable in a z-direction, and the bobbins are individually controllable in the z-direction. Each stitching head is paired with a bobbin. Each pair of stitching heads and the bobbins is controlled synchronously in the z-direction. The stitching system is well-suited for stitching preforms of aircraft wing covers and other preforms having variable thickness and compound, contoured three-dimensional surfaces.

  15. Ranking the whole MEDLINE database according to a large training set using text indexing.

    PubMed

    Suomela, Brian P; Andrade, Miguel A

    2005-03-24

    The MEDLINE database contains over 12 million references to scientific literature, with about 3/4 of recent articles including an abstract of the publication. Retrieval of entries using queries with keywords is useful for human users that need to obtain small selections. However, particular analyses of the literature or database developments may need the complete ranking of all the references in the MEDLINE database as to their relevance to a topic of interest. This report describes a method that does this ranking using the differences in word content between MEDLINE entries related to a topic and the whole of MEDLINE, in a computational time appropriate for an article search query engine. We tested the capabilities of our system to retrieve MEDLINE references which are relevant to the subject of stem cells. We took advantage of the existing annotation of references with terms from the MeSH hierarchical vocabulary (Medical Subject Headings, developed at the National Library of Medicine). A training set of 81,416 references was constructed by selecting entries annotated with the MeSH term stem cells or some child in its sub tree. Frequencies of all nouns, verbs, and adjectives in the training set were computed and the ratios of word frequencies in the training set to those in the entire MEDLINE were used to score references. Self-consistency of the algorithm, benchmarked with a test set containing the training set and an equal number of references randomly selected from MEDLINE was better using nouns (79%) than adjectives (73%) or verbs (70%). The evaluation of the system with 6,923 references not used for training, containing 204 articles relevant to stem cells according to a human expert, indicated a recall of 65% for a precision of 65%. This strategy appears to be useful for predicting the relevance of MEDLINE references to a given concept. The method is simple and can be used with any user-defined training set. Choice of the part of speech of the words used for classification has important effects on performance. Lists of words, scripts, and additional information are available from the web address http://www.ogic.ca/projects/ks2004/.

  16. Publications in acoustics and noise control from the NASA Langley Research Center during 1940-1976

    NASA Technical Reports Server (NTRS)

    Fryer, B. A. (Compiler)

    1977-01-01

    Reference lists are presented of published research papers in various areas of acoustics and noise control for the period 1940-1976. The references are listed chronologically and are grouped under the following general headings: (1) Duct acoustics; (2) propagation and operations; (3) rotating blade noise; (4) jet noise; (5) sonic boom; (6) flow-surface interaction noise; (7) human response; (8) structural response; (9) prediction; and (10) miscellaneous.

  17. Preliminary assessment of rover power systems for the Mars Rover Sample Return Mission

    NASA Technical Reports Server (NTRS)

    Bents, D. J.

    1989-01-01

    Four isotope power system concepts were presented and compared on a common basis for application to on-board electrical prime power for an autonomous planetary rover vehicle. A representative design point corresponding to the Mars Rover Sample Return (MRSR) preliminary mission requirements (500 W) was selected for comparison purposes. All systems concepts utilize the General Purpose Heat Source (GPHS) isotope heat source developed by DOE. Two of the concepts employ thermoelectric (TE) conversion: one using the GPHS Radioisotope Thermoelectric Generator (RTG) used as a reference case, the other using an advanced RTG with improved thermoelectric materials. The other two concepts employed are dynamic isotope power systems (DIPS): one using a closed Brayton cycle (CBC) turboalternator, and the other using a free piston Stirling cycle engine/linear alternator (FPSE) with integrated heat source/heater head. Near-term technology levels have been assumed for concept characterization using component technology figure-of-merit values taken from the published literature. For example, the CBC characterization draws from the historical test database accumulated from space Brayton cycle subsystems and components from the NASA B engine through the mini-Brayton rotating unit. TE system performance is estimated from Voyager/multihundred Watt (MHW)-RTG flight experience through Mod-RTG performance estimates considering recent advances in TE materials under the DOD/DOE/NASA SP-100 and NASA Committee on Scientific and Technological Information programs. The Stirling DIPS system is characterized from scaled-down Space Power Demonstrator Engine (SPDE) data using the GPHS directly incorporated into the heater head. The characterization/comparison results presented here differ from previous comparison of isotope power (made for LEO applications) because of the elevated background temperature on the Martian surface compared to LEO, and the higher sensitivity of dynamic systems to elevated s

  18. Reference charts of fetal biometric parameters in 31,476 Brazilian singleton pregnancies.

    PubMed

    Araujo Júnior, Edward; Martins Santana, Eduardo Félix; Martins, Wellington P; Júnior, Julio Elito; Ruano, Rodrigo; Pires, Claudio Rodrigues; Filho, Sebastião Marques Zanforlin

    2014-07-01

    The purpose of this study was to establish reference charts of fetal biometric parameters measured by 2-dimensional sonography in a large Brazilian population. A cross-sectional retrospective study was conducted including 31,476 low-risk singleton pregnancies between 18 and 38 weeks' gestation. The following fetal parameters were measured: biparietal diameter, head circumference, abdominal circumference, femur length, and estimated fetal weight. To assess the correlation between the fetal biometric parameters and gestational age, polynomial regression models were created, with adjustments made by the determination coefficient (R(2)). The means ± SDs of the biparietal diameter, head circumference, abdominal circumference, femur length, and estimated fetal weight measurements at 18 and 38 weeks were 4.2 ± 2.34 and 9.1 ± 4.0 cm, 15.3 ± 7.56 and 32.3 ± 11.75 cm, 13.3 ± 10.42 and 33.4 ± 20.06 cm, 2.8 ± 2.17 and 7.2 ± 3.58 cm, and 256.34 ± 34.03 and 3169.55 ± 416.93 g, respectively. Strong correlations were observed between all fetal biometric parameters and gestational age, best represented by second-degree equations, with R(2) values of 0.95, 0.96, 0.95, 0.95, and 0.95 for biparietal diameter, head circumference, abdominal circumference, femur length, and estimated fetal weight. Fetal biometric parameters were determined for a large Brazilian population, and they may serve as reference values in cases with a high risk of intrauterine growth disorders. © 2014 by the American Institute of Ultrasound in Medicine.

  19. A head-up display for low-visibility approach and landing

    NASA Technical Reports Server (NTRS)

    Bray, R. S.; Scott, B. C.

    1981-01-01

    An electronic flight-guidance display format was designed for use in evaluations of the collimated head-up display concept in low-visibility landings of transport aircraft. In the design process of iterative evaluation and modification, some general principles, or guidelines, applicable to such flight displays were suggested. The usefulness of an indication of instantaneous inertial flightpath was clearly demonstrated, particularly in low-altitude transition to visual references. Evaluator pilot acceptance of the unfamiliar display concepts was very positive when careful attention was given to indoctrination and training.

  20. Dynamic and kinematic strategies for head movement control

    NASA Technical Reports Server (NTRS)

    Peterson, B. W.; Choi, H.; Hain, T.; Keshner, E.; Peng, G. C.

    2001-01-01

    This paper describes our analysis of the complex head-neck system using a combination of experimental and modeling approaches. Dynamical analysis of head movements and EMG activation elicited by perturbation of trunk position has examined functional contributions of biomechanically and neurally generated forces in lumped systems with greatly simplified kinematics. This has revealed that visual and voluntary control of neck muscles and the dynamic and static vestibulocollic and cervicocollic reflexes preferentially govern head-neck system state in different frequency domains. It also documents redundant control, which allows the system to compensate for lesions and creates a potential for substantial variability within and between subjects. Kinematic studies have indicated the existence of reciprocal and co-contraction strategies for voluntary force generation, of a vestibulocollic strategy for stabilizing the head during body perturbations and of at least two strategies for voluntary head tracking. Each strategy appears to be executed by a specific muscle synergy that is presumably optimized to efficiently meet the demands of the task.

  1. Non-intrusive head movement analysis of videotaped seizures of epileptic origin.

    PubMed

    Mandal, Bappaditya; Eng, How-Lung; Lu, Haiping; Chan, Derrick W S; Ng, Yen-Ling

    2012-01-01

    In this work we propose a non-intrusive video analytic system for patient's body parts movement analysis in Epilepsy Monitoring Unit. The system utilizes skin color modeling, head/face pose template matching and face detection to analyze and quantify the head movements. Epileptic patients' heads are analyzed holistically to infer seizure and normal random movements. The patient does not require to wear any special clothing, markers or sensors, hence it is totally non-intrusive. The user initializes the person-specific skin color and selects few face/head poses in the initial few frames. The system then tracks the head/face and extracts spatio-temporal features. Support vector machines are then used on these features to classify seizure-like movements from normal random movements. Experiments are performed on numerous long hour video sequences captured in an Epilepsy Monitoring Unit at a local hospital. The results demonstrate the feasibility of the proposed system in pediatric epilepsy monitoring and seizure detection.

  2. Design and Experimental Evaluation of a Non-Invasive Microwave Head Imaging System for Intracranial Haemorrhage Detection

    PubMed Central

    Mobashsher, A. T.; Bialkowski, K. S.; Abbosh, A. M.; Crozier, S.

    2016-01-01

    An intracranial haemorrhage is a life threatening medical emergency, yet only a fraction of the patients receive treatment in time, primarily due to the transport delay in accessing diagnostic equipment in hospitals such as Magnetic Resonance Imaging or Computed Tomography. A mono-static microwave head imaging system that can be carried in an ambulance for the detection and localization of intracranial haemorrhage is presented. The system employs a single ultra-wideband antenna as sensing element to transmit signals in low microwave frequencies towards the head and capture backscattered signals. The compact and low-profile antenna provides stable directional radiation patterns over the operating bandwidth in both near and far-fields. Numerical analysis of the head imaging system with a realistic head model in various situations is performed to realize the scattering mechanism of haemorrhage. A modified delay-and-summation back-projection algorithm, which includes effects of surface waves and a distance-dependent effective permittivity model, is proposed for signal and image post-processing. The efficacy of the automated head imaging system is evaluated using a 3D-printed human head phantom with frequency dispersive dielectric properties including emulated haemorrhages with different sizes located at different depths. Scattered signals are acquired with a compact transceiver in a mono-static circular scanning profile. The reconstructed images demonstrate that the system is capable of detecting haemorrhages as small as 1 cm3. While quantitative analyses reveal that the quality of images gradually degrades with the increase of the haemorrhage’s depth due to the reduction of signal penetration inside the head; rigorous statistical analysis suggests that substantial improvement in image quality can be obtained by increasing the data samples collected around the head. The proposed head imaging prototype along with the processing algorithm demonstrates its feasibility for potential use in ambulances as an effective and low cost diagnostic tool to assure timely triaging of intracranial hemorrhage patients. PMID:27073994

  3. Genetics Home Reference: Legg-Calvé-Perthes disease

    MedlinePlus

    ... link) LEGG-CALVE-PERTHES DISEASE MedGen (1 link) Avascular necrosis of the capital femoral epiphysis Sources for This ... at onset-dependent presentations of premature hip osteoarthritis, avascular necrosis of the femoral head, or Legg-Calvé-Perthes ...

  4. Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel

    2011-03-15

    Purpose: To develop a computed tomography (CT) organ dose estimation method designed to readily provide organ doses in a reference adult male and female for different scan ranges to investigate the degree to which existing commercial programs can reasonably match organ doses defined in these more anatomically realistic adult hybrid phantomsMethods: The x-ray fan beam in the SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code MCNPX2.6. The simulated CT scanner model was validated through comparison with experimentally measured lateral free-in-air dose profiles and computed tomography dose index (CTDI) values. The reference adult malemore » and female hybrid phantoms were coupled with the established CT scanner model following arm removal to simulate clinical head and other body region scans. A set of organ dose matrices were calculated for a series of consecutive axial scans ranging from the top of the head to the bottom of the phantoms with a beam thickness of 10 mm and the tube potentials of 80, 100, and 120 kVp. The organ doses for head, chest, and abdomen/pelvis examinations were calculated based on the organ dose matrices and compared to those obtained from two commercial programs, CT-EXPO and CTDOSIMETRY. Organ dose calculations were repeated for an adult stylized phantom by using the same simulation method used for the adult hybrid phantom. Results: Comparisons of both lateral free-in-air dose profiles and CTDI values through experimental measurement with the Monte Carlo simulations showed good agreement to within 9%. Organ doses for head, chest, and abdomen/pelvis scans reported in the commercial programs exceeded those from the Monte Carlo calculations in both the hybrid and stylized phantoms in this study, sometimes by orders of magnitude. Conclusions: The organ dose estimation method and dose matrices established in this study readily provides organ doses for a reference adult male and female for different CT scan ranges and technical parameters. Organ doses from existing commercial programs do not reasonably match organ doses calculated for the hybrid phantoms due to differences in phantom anatomy, as well as differences in organ dose scaling parameters. The organ dose matrices developed in this study will be extended to cover different technical parameters, CT scanner models, and various age groups.« less

  5. A rigid motion correction method for helical computed tomography (CT)

    NASA Astrophysics Data System (ADS)

    Kim, J.-H.; Nuyts, J.; Kyme, A.; Kuncic, Z.; Fulton, R.

    2015-03-01

    We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed and the phantom. Motion correction was performed by restoring projection consistency using data from the motion tracking system, and reconstructing with an iterative fully 3D algorithm. Motion correction accuracy was evaluated by comparing reconstructed images with a stationary reference scan. We also investigated the effects on accuracy of tracker sampling rate, measurement jitter, interpolation of tracker measurements, and the synchronization of motion data and CT projections. After optimization of these aspects, motion corrected images corresponded remarkably closely to images of the stationary phantom with correlation and similarity coefficients both above 0.9. We performed a simulation study using volunteer head motion and found similarly that our method is capable of compensating effectively for realistic human head movements. To the best of our knowledge, this is the first practical demonstration of generalized rigid motion correction in helical CT. Its clinical value, which we have yet to explore, may be significant. For example it could reduce the necessity for repeat scans and resource-intensive anesthetic and sedation procedures in patient groups prone to motion, such as young children. It is not only applicable to dedicated CT imaging, but also to hybrid PET/CT and SPECT/CT, where it could also ensure an accurate CT image for lesion localization and attenuation correction of the functional image data.

  6. Correction for human head motion in helical x-ray CT

    NASA Astrophysics Data System (ADS)

    Kim, J.-H.; Sun, T.; Alcheikh, A. R.; Kuncic, Z.; Nuyts, J.; Fulton, R.

    2016-02-01

    Correction for rigid object motion in helical CT can be achieved by reconstructing from a modified source-detector orbit, determined by the object motion during the scan. This ensures that all projections are consistent, but it does not guarantee that the projections are complete in the sense of being sufficient for exact reconstruction. We have previously shown with phantom measurements that motion-corrected helical CT scans can suffer from data-insufficiency, in particular for severe motions and at high pitch. To study whether such data-insufficiency artefacts could also affect the motion-corrected CT images of patients undergoing head CT scans, we used an optical motion tracking system to record the head movements of 10 healthy volunteers while they executed each of the 4 different types of motion (‘no’, slight, moderate and severe) for 60 s. From these data we simulated 354 motion-affected CT scans of a voxelized human head phantom and reconstructed them with and without motion correction. For each simulation, motion-corrected (MC) images were compared with the motion-free reference, by visual inspection and with quantitative similarity metrics. Motion correction improved similarity metrics in all simulations. Of the 270 simulations performed with moderate or less motion, only 2 resulted in visible residual artefacts in the MC images. The maximum range of motion in these simulations would encompass that encountered in the vast majority of clinical scans. With severe motion, residual artefacts were observed in about 60% of the simulations. We also evaluated a new method of mapping local data sufficiency based on the degree to which Tuy’s condition is locally satisfied, and observed that areas with high Tuy values corresponded to the locations of residual artefacts in the MC images. We conclude that our method can provide accurate and artefact-free MC images with most types of head motion likely to be encountered in CT imaging, provided that the motion can be accurately determined.

  7. Head-mounted active noise control system with virtual sensing technique

    NASA Astrophysics Data System (ADS)

    Miyazaki, Nobuhiro; Kajikawa, Yoshinobu

    2015-03-01

    In this paper, we apply a virtual sensing technique to a head-mounted active noise control (ANC) system we have already proposed. The proposed ANC system can reduce narrowband noise while improving the noise reduction ability at the desired locations. A head-mounted ANC system based on an adaptive feedback structure can reduce noise with periodicity or narrowband components. However, since quiet zones are formed only at the locations of error microphones, an adequate noise reduction cannot be achieved at the locations where error microphones cannot be placed such as near the eardrums. A solution to this problem is to apply a virtual sensing technique. A virtual sensing ANC system can achieve higher noise reduction at the desired locations by measuring the system models from physical sensors to virtual sensors, which will be used in the online operation of the virtual sensing ANC algorithm. Hence, we attempt to achieve the maximum noise reduction near the eardrums by applying the virtual sensing technique to the head-mounted ANC system. However, it is impossible to place the microphone near the eardrums. Therefore, the system models from physical sensors to virtual sensors are estimated using the Head And Torso Simulator (HATS) instead of human ears. Some simulation, experimental, and subjective assessment results demonstrate that the head-mounted ANC system with virtual sensing is superior to that without virtual sensing in terms of the noise reduction ability at the desired locations.

  8. Systemic antibiotic use for nonbacterial dermatological conditions among referring providers.

    PubMed

    Haynes, Dylan; Lasarev, Michael; Keller, Jesse

    2018-05-01

    As usage of systemic antibiotic therapies has increased, so too has bacterial resistance. Antibiotic stewardship thus rests in part on judicious use of empiric treatment. The specific factors which underlie erroneous prescription patterns for dermatological conditions have not yet been well elucidated. The objective of this study was to identify whether a predefined group of dermatologic conditions under the heading "pseudobacterial"-including eczematous conditions, arthropod assault, herpes zoster, neurodermatoses, autoimmune blistering disorders, and neutrophilic dermatoses-are associated with increased antibiotic use prior to dermatology referral. This observational prospective study included 207 participants referred to an academic dermatology referral center for acute skin conditions which were ultimately deemed to be of a nonbacterial cause. Preceding antibiotic prescription, final diagnosis, and patient, and provider characteristics were reviewed. Antibiotic prescription were provided to 31/207 individuals. Patients with pseudobacterial diagnoses (66/207 individuals) had 4.79 (95% CI, 2.03-11.3) times the odds of empiric antibiotic treatment compared to all others. Rural referring providers (OR, 8.54; 95% CI, 1.81-40.3) and referring providers in areas with a low density of medical specialists (OR, 3.70; 95% CI, 1.43-10.0) also displayed increased odds of empiric antibiotic prescription for nonbacterial skin disease, though the former finding may be limited by the low number of rural vs. urban providers (7 vs. 200) included in the study. Patients with noninfectious pseudobacterial dermatological conditions experienced greater odds for unnecessary exposure to antibiotics. Additional independent risk factors included rural settings and diminished access to specialist care. © 2018 The International Society of Dermatology.

  9. Fuzzy adaptive integration scheme for low-cost SINS/GPS navigation system

    NASA Astrophysics Data System (ADS)

    Nourmohammadi, Hossein; Keighobadi, Jafar

    2018-01-01

    Due to weak stand-alone accuracy as well as poor run-to-run stability of micro-electro mechanical system (MEMS)-based inertial sensors, special approaches are required to integrate low-cost strap-down inertial navigation system (SINS) with global positioning system (GPS), particularly in long-term applications. This paper aims to enhance long-term performance of conventional SINS/GPS navigation systems using a fuzzy adaptive integration scheme. The main concept behind the proposed adaptive integration is the good performance of attitude-heading reference system (AHRS) in low-accelerated motions and its degradation in maneuvered or accelerated motions. Depending on vehicle maneuvers, gravity-based attitude angles can be intelligently utilized to improve orientation estimation in the SINS. Knowledge-based fuzzy inference system is developed for decision-making between the AHRS and the SINS according to vehicle maneuvering conditions. Inertial measurements are the main input data of the fuzzy system to determine the maneuvering level during the vehicle motions. Accordingly, appropriate weighting coefficients are produced to combine the SINS/GPS and the AHRS, efficiently. The assessment of the proposed integrated navigation system is conducted via real data in airborne tests.

  10. Assembly And Initial Characterization Of A Panel Of 85 Genomically Validated Cell Lines From Diverse Head And Neck Tumor Sites

    PubMed Central

    Zhao, Mei; Sano, Daisuke; Pickering, Curtis R.; Jasser, Samar A.; Henderson, Ying C.; Clayman, Gary L.; Sturgis, Erich M.; Ow, Thomas J.; Lotan, Reuben; Carey, Thomas E.; Sacks, Peter G.; Grandis, Jennifer R.; Sidransky, David; Heldin, Nils Erik; Myers, Jeffrey N.

    2011-01-01

    Purpose Human cell lines are useful for studying cancer biology and pre-clinically modeling cancer therapy, but can be misidentified and cross contamination is unfortunately common. The purpose of this study was to develop a panel of validated head and neck cell lines representing the spectrum of tissue sites and histologies that could be used for studying the molecular, genetic, and phenotypic diversity of head and neck cancer. Methods A panel of 122 clinically and phenotypically diverse head and neck cell lines from head and neck squamous cell carcinoma (HNSCC), thyroid cancer, cutaneous squamous cell carcinoma, adenoid cystic carcinoma, oral leukoplakia, immortalized primary keratinocytes, and normal epithelium, was assembled from the collections of several individuals and institutions. Authenticity was verified by performing short tandem repeat (STR) analysis. Human papillomavirus (HPV) status and cell morphology were also determined. Results Eighty-five of the 122 cell lines had unique genetic profiles. HPV-16 DNA was detected in 2 cell lines. These 85 cell lines included cell lines from the major head and neck primary tumor sites, and close examination demonstrates a wide range of in vitro phenotypes. Conclusion This panel of 85 genomically validated head and neck cell lines represents a valuable resource for the head and neck cancer research community that can help advance understanding of the disease by providing a standard reference for cell lines that can be utilized for biological as well as preclinical studies. PMID:21868764

  11. Neck muscle activation and head postures in common high performance aerial combat maneuvers.

    PubMed

    Netto, Kevin J; Burnett, Angus F

    2006-10-01

    Neck injuries are common in high performance combat pilots and have been attributed to high gravitational forces and the non-neutral head postures adopted during aerial combat maneuvers. There is still little known about the pathomechanics of these injuries. Six Royal Australian Air Force Hawk pilots flew a sortie that included combinations of three +Gz levels (1, 3, and 5) and four head postures (Neutral, Turn, Extension, and Check-6). Surface electromyography from neck and shoulder muscles was recorded in flight. Three-dimensional measures of head postures adopted in flight were estimated postflight with respect to end-range of the cervical spine using an electromagnetic tracking device. Mean muscle activation increased significantly with both increasing +Gz and non-neutral head postures. Check-6 at +5 Gz (mean activation of all muscles = 51% MVIC) elicited significantly greater muscle activation in most muscles when compared with Neutral, Extension, and Turn head postures. High levels of muscle co-contraction were evident in high acceleration and non-neutral head postures. Head kinematics showed Check-6 was closest to end-range in any movement plane (86% ROM in rotation) and produced the greatest magnitude of rotation in other planes. Turn and Extension showed a large magnitude of rotation with reference to end-range in the primary plane of motion but displayed smaller rotations in other planes. High levels of neck muscle activation and co-contraction due to high +Gz and head postures close to end range were evident in this study, suggesting the major influence of these factors on the pathomechanics of neck injuries in high performance combat pilots.

  12. Stabilization and mobility of the head, neck and trunk in horses during overground locomotion: comparisons with humans and other primates

    PubMed Central

    Dunbar, Donald C.; Macpherson, Jane M.; Simmons, Roger W.; Zarcades, Athina

    2009-01-01

    SUMMARY Segmental kinematics were investigated in horses during overground locomotion and compared with published reports on humans and other primates to determine the impact of a large neck on rotational mobility (>20deg.) and stability (≤20deg.) of the head and trunk. Three adult horses (Equus caballus) performing walks, trots and canters were videotaped in lateral view. Data analysis included locomotor velocity, segmental positions, pitch and linear displacements and velocities, and head displacement frequencies. Equine, human and monkey skulls and cervical spines were measured to estimate eye and vestibular arc length during head pitch displacements. Horses stabilized all three segments in all planes during all three gaits, unlike monkeys and humans who make large head pitch and yaw rotations during walks, and monkeys that make large trunk pitch rotations during gallops. Equine head angular displacements and velocities, with some exceptions during walks, were smaller than in humans and other primates. Nevertheless, owing to greater off-axis distances, orbital and vestibular arc lengths remained larger in horses, with the exception of head–neck axial pitch during trots, in which equine arc lengths were smaller than in running humans. Unlike monkeys and humans, equine head peak-frequency ranges fell within the estimated range in which inertia has a compensatory stabilizing effect. This inertial effect was typically over-ridden, however, by muscular or ligamentous intervention. Thus, equine head pitch was not consistently compensatory, as reported in humans. The equine neck isolated the head from the trunk enabling both segments to provide a spatial reference frame. PMID:19043061

  13. Individually customisable non-invasive head immobilisation system for non-human primates with an option for voluntary engagement.

    PubMed

    Slater, Heather; Milne, Alice E; Wilson, Benjamin; Muers, Ross S; Balezeau, Fabien; Hunter, David; Thiele, Alexander; Griffiths, Timothy D; Petkov, Christopher I

    2016-08-30

    Head immobilisation is often necessary for neuroscientific procedures. A number of Non-invasive Head Immobilisation Systems (NHIS) for monkeys are available, but the need remains for a feasible integrated system combining a broad range of essential features. We developed an individualised macaque NHIS addressing several animal welfare and scientific needs. The system comprises a customised-to-fit facemask that can be used separately or combined with a back piece to form a full-head helmet. The system permits presentation of visual and auditory stimuli during immobilisation and provides mouth access for reward. The facemask was incorporated into an automated voluntary training system, allowing the animals to engage with it for increasing periods leading to full head immobilisation. We evaluated the system during performance on several auditory or visual behavioural tasks with testing sessions lasting 1.5-2h, used thermal imaging to monitor for and prevent pressure points, and measured head movement using MRI. A comprehensive evaluation of the system is provided in relation to several scientific and animal welfare requirements. Behavioural results were often comparable to those obtained with surgical implants. Cost-benefit analyses were conducted comparing the system with surgical options, highlighting the benefits of implementing the non-invasive option. The system has a number of potential applications and could be an important tool in neuroscientific research, when direct access to the brain for neuronal recordings is not required, offering the opportunity to conduct non-invasive experiments while improving animal welfare and reducing reliance on surgically implanted head posts. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  14. The research on a novel type of the solar-blind UV head-mounted displays

    NASA Astrophysics Data System (ADS)

    Zhao, Shun-long

    2011-08-01

    Ultraviolet technology of detecting is playing a more and more important role in the field of civil application, especially in the corona discharge detection, in modern society. Now the UV imaging detector is one of the most important equipments in power equipment flaws detection. And the modern head-mounted displays (HMDs) have shown the applications in the fields of military, industry production, medical treatment, entertainment, 3D visualization, education and training. We applied the system of head-mounted displays to the UV image detection, and a novel type of head-mounted displays is presented: the solar-blind UV head-mounted displays. And the structure is given. By the solar-blind UV head-mounted displays, a real-time, isometric and visible image of the corona discharge is correctly displayed upon the background scene where it exists. The user will see the visible image of the corona discharge on the real scene rather than on a small screen. Then the user can easily find out the power equipment flaws and repair them. Compared with the traditional UV imaging detector, the introducing of the HMDs simplifies the structure of the whole system. The original visible spectrum optical system is replaced by the eye in the solar-blind UV head-mounted displays. And the optical image fusion technology would be used rather than the digital image fusion system which is necessary in traditional UV imaging detector. That means the visible spectrum optical system and digital image fusion system are not necessary. This makes the whole system cheaper than the traditional UV imaging detector. Another advantage of the solar-blind UV head-mounted displays is that the two hands of user will be free. So while observing the corona discharge the user can do some things about it. Therefore the solar-blind UV head-mounted displays can make the corona discharge expose itself to the user in a better way, and it will play an important role in corona detection in the future.

  15. Top tether effectiveness during side impacts.

    PubMed

    Majstorovic, Jordan; Bing, Julie; Dahle, Eric; Bolte, John; Kang, Yun-Seok

    2018-02-28

    Few studies have looked at the effectiveness of the top tether during side impacts. In these studies, limited anthropomorphic test device (ATD) data were collected and/or few side impact scenarios were observed. The goal of this study was to further understand the effects of the top tether on ATD responses and child restraint system (CRS) kinematics during various side impact conditions. A series of high-speed near-side and far-side sled tests were performed using the FMVSS213 side impact sled buck and Q3s ATD. Tests were performed at both 10° and 30° impacts with respect to the pure lateral direction. Two child restraints, CRS A and CRS B, were attached to the bench using flexible lower anchors. Each test scenario was performed with the presence and absence of a top tether. Instrumentation recorded Q3s responses and CRS kinematics, and the identical test scenarios with and without a top tether attachment were compared. For the far-side lateral (10°) and oblique (30°) impacts, top tether attachment increased resultant head accelerations by 8-38% and head injury criterion (HIC 15 ) values by 20-140%. However, the top tether was effective in reducing lateral head excursion by 5-25%. For near-side impacts, the top tether resulted in less than 10% increases in both resultant head acceleration and HIC 15 in the lateral impact direction. For near-side oblique impacts, the top tether increased HIC 15 by 17.3% for CRS A and decreased it by 19.5% for CRS B. However, the injury values determined from both impact conditions were below current injury assessment reference values (IARVs). Additionally, the top tether proved beneficial in preventing forward and lateral CRS rotations. The results show that the effects of the top tether on Q3s responses were dependent on impact type, impact angle, and CRS. Tether attachments that increased head accelerations and HIC 15 values were generally counterbalanced by a reduction in head excursion and CRS rotation compared to nontethered scenarios.

  16. Simulation of Sub-Drains Performance Using Visual MODFLOW for Slope Water Seepage Problem

    NASA Astrophysics Data System (ADS)

    Baharuddin, M. F. T.; Tajudin, S. A. A.; Abidin, M. H. Z.; Yusoff, N. A.

    2016-07-01

    Numerical simulation technique was used for investigating water seepage problem at the Botanic Park Kuala Lumpur. A proposed sub-drains installation in problematic site location was simulated using Modular Three-Dimensional Finite Difference Groundwater Flow (MODFLOW) software. The results of simulation heads during transient condition showed that heads in between 43 m (water seepage occurred at level 2) until 45 m (water seepage occurred at level 4) which heads measurement are referred to mean sea level. However, elevations measurements for level 2 showed the values between 41 to 42 m from mean sea level and elevations for level 4 between 42 to 45 m from mean sea level. These results indicated an increase in heads for level 2 and level 4 between 1 to 2 m when compared to elevations slope at the level 2 and level 4. The head increases surpass the elevation level of the slope area that causing water seepage at level 2 and level 4. In order to overcome this problems, the heads level need to be decrease to 1 until 2 m by using two options of sub-drain dimension size. Sub-drain with the dimension of 0.0750 m (diameter), 0.10 m (length) and using 4.90 m spacing was the best method to use as it was able to decrease the heads to the required levels of 1 to 2 m.

  17. [Clinical application and optimization of HEAD-US quantitative ultrasound assessment scale for hemophilic arthropathy].

    PubMed

    Li, J; Guo, X J; Ding, X L; Lyu, B M; Xiao, J; Sun, Q L; Li, D S; Zhang, W F; Zhou, J C; Li, C P; Yang, R C

    2018-02-14

    Objective: To assess the feasibility of HEAD-US scale in the clinical application of hemophilic arthropathy (HA) and propose an optimized ultrasound scoring system. Methods: From July 2015 to August 2017, 1 035 joints ultrasonographic examinations were performed in 91 patients. Melchiorre, HEAD-US (Hemophilic Early Arthropathy Detection with UltraSound) and HEAD-US-C (HEAD-US in China) scale scores were used respectively to analyze the results. The correlations between three ultrasound scales and Hemophilia Joint Health Scores (HJHS) were evaluated. The sensitivity differences of the above Ultrasonic scoring systems in evaluation of HA were compared. Results: All the 91 patients were male, with median age of 16 (4-55) years old, including 86 cases of hemophilia A and 5 cases hemophilia B. The median ( P 25 , P 75 ) of Melchiorre, HEAD-US and HEAD-US-C scores of 1 035 joints were 2(0,6), 1(0,5) and 2(0,6), respectively, and the correlation coefficients compared with HJHS was 0.747, 0.762 and 0.765 respectively, with statistical significance ( P <0.001). The positive rates of Melchiorre, HEAD-US-C and HEAD-US scale score were 63.0% (95% CI 59.7%-65.9%), 59.5% (95% CI 56.5%-62.4%) and 56.6% (95% CI 53.6%-59.6%) respectively, and the difference was statistically significant ( P <0.001). Even for 336 cases of asymptomatic joints, the positive rates of Melchiorre, HEAD-US-C and HEAD-US scale score were 25.0% (95% CI 20.6%-29.6%), 17.0% (95% CI 12.6%-21.1%) and 11.9% (95% CI 8.4%-15.7%) respectively, and the difference was statistically significant ( P <0.001). There were significant changes ( P <0.05) in the ultrasonographic score of HA before and after onset of hemorrhage in 107 joints of 40 patients. The difference in variation amplitude of HEAD-US-C scores and HEAD-US scores before and after joint bleeding was statistically significant ( P <0.001). Conclusion: Compared with Melchiorre, there were similar good correlations between HEAD-US, HEAD-US-C and HJHS. HEAD-US ultrasound scoring system is quick, convenient and simple to use. The optimized HEAD-US-C scale score is more sensitive than HEAD-US, especially for patients with HA who have subclinical state, which make up for insufficiency of sensitivity in HEAD-US scoring system.

  18. Augmented reality as an aid in maxillofacial surgery: validation of a wearable system allowing maxillary repositioning.

    PubMed

    Badiali, Giovanni; Ferrari, Vincenzo; Cutolo, Fabrizio; Freschi, Cinzia; Caramella, Davide; Bianchi, Alberto; Marchetti, Claudio

    2014-12-01

    We present a newly designed, localiser-free, head-mounted system featuring augmented reality as an aid to maxillofacial bone surgery, and assess the potential utility of the device by conducting a feasibility study and validation. Our head-mounted wearable system facilitating augmented surgery was developed as a stand-alone, video-based, see-through device in which the visual features were adapted to facilitate maxillofacial bone surgery. We implement a strategy designed to present augmented reality information to the operating surgeon. LeFort1 osteotomy was chosen as the test procedure. The system is designed to exhibit virtual planning overlaying the details of a real patient. We implemented a method allowing performance of waferless, augmented-reality assisted bone repositioning. In vitro testing was conducted on a physical replica of a human skull, and the augmented reality system was used to perform LeFort1 maxillary repositioning. Surgical accuracy was measured with the aid of an optical navigation system that recorded the coordinates of three reference points (located in anterior, posterior right, and posterior left positions) on the repositioned maxilla. The outcomes were compared with those expected to be achievable in a three-dimensional environment. Data were derived using three levels of surgical planning, of increasing complexity, and for nine different operators with varying levels of surgical skill. The mean error was 1.70 ± 0.51 mm. The axial errors were 0.89 ± 0.54 mm on the sagittal axis, 0.60 ± 0.20 mm on the frontal axis, and 1.06 ± 0.40 mm on the craniocaudal axis. The simplest plan was associated with a slightly lower mean error (1.58 ± 0.37 mm) compared with the more complex plans (medium: 1.82 ± 0.71 mm; difficult: 1.70 ± 0.45 mm). The mean error for the anterior reference point was lower (1.33 ± 0.58 mm) than those for both the posterior right (1.72 ± 0.24 mm) and posterior left points (2.05 ± 0.47 mm). No significant difference in terms of error was noticed among operators, despite variations in surgical experience. Feedback from surgeons was acceptable; all tests were completed within 15 min and the tool was considered to be both comfortable and usable in practice. We used a new localiser-free, head-mounted, wearable, stereoscopic, video see-through display to develop a useful strategy affording surgeons access to augmented reality information. Our device appears to be accurate when used to assist in waferless maxillary repositioning. Our results suggest that the method can potentially be extended for use with many surgical procedures on the facial skeleton. Further, our positive results suggest that it would be appropriate to proceed to in vivo testing to assess surgical accuracy under real clinical conditions. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Shrunken head (tsantsa): a complete forensic analysis procedure.

    PubMed

    Charlier, P; Huynh-Charlier, I; Brun, L; Hervé, C; de la Grandmaison, G Lorin

    2012-10-10

    Based on the analysis of shrunken heads referred to our forensic laboratory for anthropological expertise, and data from both anthropological and medical literature, we propose a complete forensic procedure for the analysis of such pieces. A list of 14 original morphological criteria has been developed, based on the global aspect, color, physical deformation, anatomical details, and eventual associated material (wood, vegetal fibers, sand, charcoals, etc.). Such criteria have been tested on a control sample of 20 tsantsa (i.e. shrunken heads from the Jivaro or Shuar tribes of South America). Further complementary analyses are described such as CT-scan and microscopic examination. Such expertise is more and more asked to forensic anthropologists and practitioners in a context of global repatriation of human artifacts to native communities. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Micro-fluid exchange coupling apparatus

    NASA Technical Reports Server (NTRS)

    Johnson, J. E., Jr.; Swartz, P. F. (Inventor)

    1980-01-01

    In a macro-fluid exchange, a hollow needle, such as a syringe needle, is provided for penetrating the fluid conduit of the animal. The syringe needle is coupled to a plenum chamber having an inlet and outlet port. The plenum chamber is coupled to the syringe needle via the intermediary of a standard quick disconnect coupling fitting. The plenum chamber is carried at the end of a drive rod which is coupled to a micrometer drive head. The micrometer drive head is slidably and pivotably coupled to a pedestal for adjusting the height and angle of inclination of the needle relative to a reference base support. The needle is positioned adjacent to the incised trachea or a blood vessel of a small animal and the micrometer drive head is operated for penetrating the fluid conduit of the animal.

  1. 48 CFR 702.170-10 - Head of the contracting activity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Head of the contracting activity. 702.170-10 Section 702.170-10 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT GENERAL DEFINITIONS OF WORDS AND TERMS Definitions 702.170-10 Head of the contracting activity. (a...

  2. The reference frame of figure-ground assignment.

    PubMed

    Vecera, Shaun P

    2004-10-01

    Figure-ground assignment involves determining which visual regions are foreground figures and which are backgrounds. Although figure-ground processes provide important inputs to high-level vision, little is known about the reference frame in which the figure's features and parts are defined. Computational approaches have suggested a retinally based, viewer-centered reference frame for figure-ground assignment, but figural assignment could also be computed on the basis of environmental regularities in an environmental reference frame. The present research used a newly discovered cue, lower region, to examine the reference frame of figure-ground assignment. Possible reference frames were misaligned by changing the orientation of viewers by having them tilt their heads (Experiments 1 and 2) or turn them upside down (Experiment 3). The results of these experiments indicated that figure-ground perception followed the orientation of the viewer, suggesting a viewer-centered reference frame for figure-ground assignment.

  3. Biomechanical considerations for assessing interactions of children and small occupants with inflatable seat belts.

    PubMed

    Rouhana, Stephen W; Sundararajan, Srinivasan; Board, Derek; Prasad, Priya; Rupp, Jonathan D; Miller, Carl S; Jeffreys, Thomas A; Schneider, Lawrence W

    2013-11-01

    NHTSA estimates that more than half of the lives saved (168,524) in car crashes between 1960 and 2002 were due to the use of seat belts. Nevertheless, while seat belts are vital to occupant crash protection, safety researchers continue efforts to further enhance the capability of seat belts in reducing injury and fatality risk in automotive crashes. Examples of seat belt design concepts that have been investigated by researchers include inflatable, 4-point, and reverse geometry seat belts. In 2011, Ford Motor Company introduced the first rear seat inflatable seat belts into production vehicles. A series of tests with child and small female-sized Anthropomorphic Test Devices (ATD) and small, elderly female Post Mortem Human Subjects (PMHS) was performed to evaluate interactions of prototype inflatable seat belts with the chest, upper torso, head and neck of children and small occupants, from infants to young adolescents. Tests simulating a 6-year-old child asleep in a booster seat, with its head lying directly on its shoulder on top of the inflatable seat belt, were considered by engineering judgment, to represent a worst case scenario for interaction of an inflating seat belt with the head and neck of a child and/or small occupant. All evaluations resulted in ATD responses below Injury Assessment Reference Values reported by Mertz et al. (2003). In addition, the tests of the PMHS subjects resulted in no injuries from interaction of the inflating seat belt with the heads, necks, and chests of the subjects. Given the results from the ATD and PMHS tests, it was concluded that the injury risk to children and small occupants from deployment of inflatable seat belt systems is low.

  4. A longitudinal analysis of intimacy processes and psychological distress among couples coping with head and neck or lung cancers.

    PubMed

    Manne, Sharon; Badr, Hoda; Kashy, Deborah A

    2012-06-01

    Individuals diagnosed with lung and head and neck (HN) cancers and their spouses are at increased risk for distress. This study assessed whether the way couples communicate about cancer and their perceptions of relationship intimacy influenced both partners' adjustment. One-hundred thirty-nine patients and their spouses [For purposes of clarity, we refer to the patients' intimate partner as the spouse, regardless of actual marital status and we reserve the term partner to refer to the other person in the couple (i.e., the patient's partner is the spouse and the spouse's partner is the patient)] completed measures of spousal communication, intimacy, and distress at three time points over 6 months. Using multilevel modeling, an over-time actor-partner interdependence model was specified that examined whether intimacy mediated associations between one's own and one's partner's reports of communication at baseline and later distress. Patients and spouses who reported greater baseline distress reported more negative baseline communication as well as lower levels of intimacy and greater distress over time. Mediation analyses showed patients' and spouses' reports of positive spousal communication were associated with less subsequent distress largely through their effects on intimacy. Clinicians working with head and neck or lung cancer patients should assess communication and intimacy because both impact couples' distress.

  5. Analysis of real-time head accelerations in collegiate football players.

    PubMed

    Duma, Stefan M; Manoogian, Sarah J; Bussone, William R; Brolinson, P Gunnar; Goforth, Mike W; Donnenwerth, Jesse J; Greenwald, Richard M; Chu, Jeffrey J; Crisco, Joseph J

    2005-01-01

    To measure and analyze head accelerations during American collegiate football practices and games. A newly developed in-helmet 6-accelerometer system that transmits data via radio frequency to a sideline receiver and laptop computer system was implemented. From the data transfer of these accelerometer traces, the sideline staff has real-time data including the head acceleration, the head injury criteria value, the severity index value, and the impact location. Data are presented for instrumented players for the entire 2003 football season, including practices and games. American collegiate football. Thirty-eight players from Virginia Tech's varsity football team. Accelerations and pathomechanics of head impacts. : A total of 3312 impacts were recorded over 35 practices and 10 games for 38 players. The average peak head acceleration, Gadd Severity Index, and Head Injury Criteria were 32 g +/- 25 g, 36 g +/- 91 g, and 26 g +/- 64 g, respectively. One concussive event was observed with a peak acceleration of 81 g, a 267 Gadd Severity Index, and 200 Head Injury Criteria. Because the concussion was not reported until the day after of the event, a retrospective diagnosis based on his history and clinical evaluation suggested a mild concussion. The primary finding of this study is that the helmet-mounted accelerometer system proved effective at collecting thousands of head impact events and providing contemporaneous head impact parameters that can be integrated with existing clinical evaluation techniques.

  6. Imaging system for cardiac planar imaging using a dedicated dual-head gamma camera

    DOEpatents

    Majewski, Stanislaw [Morgantown, VA; Umeno, Marc M [Woodinville, WA

    2011-09-13

    A cardiac imaging system employing dual gamma imaging heads co-registered with one another to provide two dynamic simultaneous views of the heart sector of a patient torso. A first gamma imaging head is positioned in a first orientation with respect to the heart sector and a second gamma imaging head is positioned in a second orientation with respect to the heart sector. An adjustment arrangement is capable of adjusting the distance between the separate imaging heads and the angle between the heads. With the angle between the imaging heads set to 180 degrees and operating in a range of 140-159 keV and at a rate of up to 500kHz, the imaging heads are co-registered to produce simultaneous dynamic recording of two stereotactic views of the heart. The use of co-registered imaging heads maximizes the uniformity of detection sensitivity of blood flow in and around the heart over the whole heart volume and minimizes radiation absorption effects. A normalization/image fusion technique is implemented pixel-by-corresponding pixel to increase signal for any cardiac region viewed in two images obtained from the two opposed detector heads for the same time bin. The imaging system is capable of producing enhanced first pass studies, bloodpool studies including planar, gated and non-gated EKG studies, planar EKG perfusion studies, and planar hot spot imaging.

  7. Light-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

    NASA Technical Reports Server (NTRS)

    Wells, Dennis L. (Inventor); Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1997-01-01

    A laser-directed ranging system has utility for use in various fields, such as telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a single video camera and a directional light source such as a laser mounted on a camera platform, and a remotely positioned operator. In one embodiment, the position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. The laser is offset vertically and horizontally from the camera, and the laser/camera platform is directed by the user to point the laser and the camera toward a target device. The image produced by the video camera is processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. A reference point is defined at a point in the video frame, which may be located outside of the image area of the camera. The disparity between the digital image of the laser spot and the reference point is calculated for use in a ranging analysis to determine range to the target.

  8. Head-target tracking control of well drilling

    NASA Astrophysics Data System (ADS)

    Agzamov, Z. V.

    2018-05-01

    The method of directional drilling trajectory control for oil and gas wells using predictive models is considered in the paper. The developed method does not apply optimization and therefore there is no need for the high-performance computing. Nevertheless, it allows following the well-plan with high precision taking into account process input saturation. Controller output is calculated both from the present target reference point of the well-plan and from well trajectory prediction with using the analytical model. This method allows following a well-plan not only on angular, but also on the Cartesian coordinates. Simulation of the control system has confirmed the high precision and operation performance with a wide range of random disturbance action.

  9. Incidental findings on computed tomography scans in children with mild head trauma.

    PubMed

    Ortega, Henry W; Vander Velden, Heidi; Reid, Samuel

    2012-09-01

    Computed tomography (CT) scans are frequently used in managing traumatic brain injuries in children. To assess incidental findings in children with head trauma undergoing CT scan and to describe any associated clinical ramifications. Retrospective review of 524 children treated in 2 emergency departments for closed head injury who received a CT scan. Overall, 137 (26.2%) patients had an incidental finding on CT scan. The most common incidental finding was sinus opacification with an air fluid level (115/137, 83.9%). Thirty-five interventions were reported in children with incidental findings. Children 2 years old or younger were more likely to receive a prescription for antibiotics (relative risk [RR] = 2.66, 95% confidence interval [CI] = 1.08-6.51) and be referred to a specialist (RR = 10.26, 95% CI = 3.56-29.56) than older children. Incidental findings in minor head trauma are common. Clinicians should be prepared to address these findings if clinically indicated.

  10. Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads.

    PubMed

    Ma, Jieshi; Xu, Canhua; Dai, Meng; You, Fusheng; Shi, Xuetao; Dong, Xiuzhen; Fu, Feng

    2014-01-01

    Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.

  11. Exploratory Study on the Methodology of Fast Imaging of Unilateral Stroke Lesions by Electrical Impedance Asymmetry in Human Heads

    PubMed Central

    Xu, Canhua; Dai, Meng; You, Fusheng; Shi, Xuetao

    2014-01-01

    Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke. PMID:25006594

  12. Otolaryngology/Head and Neck Surgery

    PubMed Central

    Trachy, R. E.; Cummings, C. W.

    1984-01-01

    The Scientific Board of the California Medical Association presents the following inventory of items of progress in otolaryngology/head and neck surgery. Each item, in the judgment of a panel of knowledgeable physicians, has recently become reasonably firmly established, both as to scientific fact and important clinical significance. The items are presented in simple epitome and an authoritative reference, both to the item itself and to the subject as a whole, is generally given for those who may be unfamiliar with a particular item. The purpose is to assist busy practitioners, students, research workers or scholars to stay abreast of these items of progress in otolaryngology/head and neck surgery that have recently achieved a substantial degree of authoritative acceptance, whether in their own field of special interest or another. The items of progress listed below were selected by the Advisory Panel to the Section on Otolaryngology/Head and Neck Surgery of the California Medical Association and the summaries were prepared under its direction. PMID:18749653

  13. Head-Up; An interdisciplinary, participatory and co-design process informing the development of a novel head and neck support for people living with progressive neck muscle weakness.

    PubMed

    Reed, Heath; Langley, Joe; Stanton, Andy; Heron, Nicola; Clarke, Zoe; Judge, Simon; McCarthy, Avril; Squire, Gill; Quinn, Ann; Wells, Oliver; Tindale, Wendy; Baxter, Susan; Shaw, Pamela J; McDermott, Christopher J

    2014-01-01

    This paper presents the Head-Up project, that aims to provide innovative head support to help improve posture, relieve pain and aid communication for people living with progressive neck muscle weakness. The initial focus is motor neurone disease. The case study illustrates collaborative, interdisciplinary research and new product development underpinned by participatory design. The study was initiated by a 2-day stakeholder workshop followed by early proof-of-concept modelling and patient need evidence building. The work subsequently led to a successful NIHR i4i application funding a 24-month iterative design process, patenting, CE marking and clinical evaluation. The evaluation has informed amendments to the proposed design refered to here as the Sheffield Support Snood (SSS). The outcome positively demonstrates use and performance improvements over current neck orthoses and the process of multidisciplinary and user engagement has created a sense of ownership by MND participants, who have since acted as advocates for the product.

  14. BabyMEG: A whole-head pediatric magnetoencephalography system for human brain development research

    NASA Astrophysics Data System (ADS)

    Okada, Yoshio; Hämäläinen, Matti; Pratt, Kevin; Mascarenas, Anthony; Miller, Paul; Han, Menglai; Robles, Jose; Cavallini, Anders; Power, Bill; Sieng, Kosal; Sun, Limin; Lew, Seok; Doshi, Chiran; Ahtam, Banu; Dinh, Christoph; Esch, Lorenz; Grant, Ellen; Nummenmaa, Aapo; Paulson, Douglas

    2016-09-01

    We developed a 375-channel, whole-head magnetoencephalography (MEG) system ("BabyMEG") for studying the electrophysiological development of human brain during the first years of life. The helmet accommodates heads up to 95% of 36-month old boys in the USA. The unique two-layer sensor array consists of: (1) 270 magnetometers (10 mm diameter, ˜15 mm coil-to-coil spacing) in the inner layer, (2) thirty-five three-axis magnetometers (20 mm × 20 mm) in the outer layer 4 cm away from the inner layer. Additionally, there are three three-axis reference magnetometers. With the help of a remotely operated position adjustment mechanism, the sensor array can be positioned to provide a uniform short spacing (mean 8.5 mm) between the sensor array and room temperature surface of the dewar. The sensors are connected to superconducting quantum interference devices (SQUIDs) operating at 4.2 K with median sensitivity levels of 7.5 fT/√Hz for the inner and 4 fT/√Hz for the outer layer sensors. SQUID outputs are digitized by a 24-bit acquisition system. A closed-cycle helium recycler provides maintenance-free continuous operation, eliminating the need for helium, with no interruption needed during MEG measurements. BabyMEG with the recycler has been fully operational from March, 2015. Ongoing spontaneous brain activity can be monitored in real time without interference from external magnetic noise sources including the recycler, using a combination of a lightly shielded two-layer magnetically shielded room, an external active shielding, a signal-space projection method, and a synthetic gradiometer approach. Evoked responses in the cortex can be clearly detected without averaging. These new design features and capabilities represent several advances in MEG, increasing the utility of this technique in basic neuroscience as well as in clinical research and patient studies.

  15. BabyMEG: A whole-head pediatric magnetoencephalography system for human brain development research.

    PubMed

    Okada, Yoshio; Hämäläinen, Matti; Pratt, Kevin; Mascarenas, Anthony; Miller, Paul; Han, Menglai; Robles, Jose; Cavallini, Anders; Power, Bill; Sieng, Kosal; Sun, Limin; Lew, Seok; Doshi, Chiran; Ahtam, Banu; Dinh, Christoph; Esch, Lorenz; Grant, Ellen; Nummenmaa, Aapo; Paulson, Douglas

    2016-09-01

    We developed a 375-channel, whole-head magnetoencephalography (MEG) system ("BabyMEG") for studying the electrophysiological development of human brain during the first years of life. The helmet accommodates heads up to 95% of 36-month old boys in the USA. The unique two-layer sensor array consists of: (1) 270 magnetometers (10 mm diameter, ∼15 mm coil-to-coil spacing) in the inner layer, (2) thirty-five three-axis magnetometers (20 mm × 20 mm) in the outer layer 4 cm away from the inner layer. Additionally, there are three three-axis reference magnetometers. With the help of a remotely operated position adjustment mechanism, the sensor array can be positioned to provide a uniform short spacing (mean 8.5 mm) between the sensor array and room temperature surface of the dewar. The sensors are connected to superconducting quantum interference devices (SQUIDs) operating at 4.2 K with median sensitivity levels of 7.5 fT/√Hz for the inner and 4 fT/√Hz for the outer layer sensors. SQUID outputs are digitized by a 24-bit acquisition system. A closed-cycle helium recycler provides maintenance-free continuous operation, eliminating the need for helium, with no interruption needed during MEG measurements. BabyMEG with the recycler has been fully operational from March, 2015. Ongoing spontaneous brain activity can be monitored in real time without interference from external magnetic noise sources including the recycler, using a combination of a lightly shielded two-layer magnetically shielded room, an external active shielding, a signal-space projection method, and a synthetic gradiometer approach. Evoked responses in the cortex can be clearly detected without averaging. These new design features and capabilities represent several advances in MEG, increasing the utility of this technique in basic neuroscience as well as in clinical research and patient studies.

  16. A multimodal physical therapy approach to the management of a patient with temporomandibular dysfunction and head and neck lymphedema: a case report

    PubMed Central

    Crane, Patricia; Feinberg, Lauren; Morris, John

    2015-01-01

    Objective and importance: There is a paucity of research that investigates therapeutic interventions of patients with concurrent head and neck lymphedema and temporomandibular dysfunction (TMD). The purpose of this case report is to describe the management and outcomes of a patient with head and neck lymphedema and TMD using a multimodal physical therapy approach. Clinical presentation: A 74-year-old male with a past medical history of head and neck lymphedema and TMD was referred to physical therapy with chief complaints of inability to open his mouth in order to eat solid food, increased neck lymphedema, temporomadibular joint pain, and inability to speak for prolonged periods of time. Interventions: The patient was treated for three visits over 4 weeks. Treatment included complete decongestive therapy (CDT), manual therapy, therapeutic exercise, and a home exercise program. Upon discharge, the patient had improved mandibular depression, decreased head and neck lymphedema, improved deep neck flexor endurance, decreased pain, and improved function on the Patient Specific Functional Scale (PSFS). Conclusion: Utilization of a multimodal physical therapy approach to treat a patient with a complex presentation yielded positive outcomes. Further research on outcomes and treatment approaches in patients with TMD and head and neck lymphedema is warranted. PMID:26309380

  17. A multimodal physical therapy approach to the management of a patient with temporomandibular dysfunction and head and neck lymphedema: a case report.

    PubMed

    Crane, Patricia; Feinberg, Lauren; Morris, John

    2015-02-01

    There is a paucity of research that investigates therapeutic interventions of patients with concurrent head and neck lymphedema and temporomandibular dysfunction (TMD). The purpose of this case report is to describe the management and outcomes of a patient with head and neck lymphedema and TMD using a multimodal physical therapy approach. A 74-year-old male with a past medical history of head and neck lymphedema and TMD was referred to physical therapy with chief complaints of inability to open his mouth in order to eat solid food, increased neck lymphedema, temporomadibular joint pain, and inability to speak for prolonged periods of time. The patient was treated for three visits over 4 weeks. Treatment included complete decongestive therapy (CDT), manual therapy, therapeutic exercise, and a home exercise program. Upon discharge, the patient had improved mandibular depression, decreased head and neck lymphedema, improved deep neck flexor endurance, decreased pain, and improved function on the Patient Specific Functional Scale (PSFS). Utilization of a multimodal physical therapy approach to treat a patient with a complex presentation yielded positive outcomes. Further research on outcomes and treatment approaches in patients with TMD and head and neck lymphedema is warranted.

  18. Use of NLM medical subject headings with the MeSH2010 thesaurus in the PORTAL-DOORS system.

    PubMed

    Taswell, Carl

    2010-01-01

    The NLM MeSH Thesaurus has been incorporated for use in the PORTAL-DOORS System (PDS) for resource metadata management on the semantic web. All 25588 descriptor records from the NLM 2010 MeSH Thesaurus have been exposed as web accessible resources by the PDS MeSH2010 Thesaurus implemented as a PDS PORTAL Registry operating as a RESTful web service. Examples of records from the PDS MeSH2010 PORTAL are demonstrated along with their use by records in other PDS PORTAL Registries that reference the concepts from the MeSH2010 Thesaurus. Use of this important biomedical terminology will greatly enhance the quality of metadata content of other PDS records thus improving cross-domain searches between different problem oriented domains and amongst different clinical specialty fields.

  19. A MATLAB-based eye tracking control system using non-invasive helmet head restraint in the macaque.

    PubMed

    De Luna, Paolo; Mohamed Mustafar, Mohamed Faiz Bin; Rainer, Gregor

    2014-09-30

    Tracking eye position is vital for behavioral and neurophysiological investigations in systems and cognitive neuroscience. Infrared camera systems which are now available can be used for eye tracking without the need to surgically implant magnetic search coils. These systems are generally employed using rigid head fixation in monkeys, which maintains the eye in a constant position and facilitates eye tracking. We investigate the use of non-rigid head fixation using a helmet that constrains only general head orientation and allows some freedom of movement. We present a MATLAB software solution to gather and process eye position data, present visual stimuli, interact with various devices, provide experimenter feedback and store data for offline analysis. Our software solution achieves excellent timing performance due to the use of data streaming, instead of the traditionally employed data storage mode for processing analog eye position data. We present behavioral data from two monkeys, demonstrating that adequate performance levels can be achieved on a simple fixation paradigm and show how performance depends on parameters such as fixation window size. Our findings suggest that non-rigid head restraint can be employed for behavioral training and testing on a variety of gaze-dependent visual paradigms, reducing the need for rigid head restraint systems for some applications. While developed for macaque monkey, our system of course can work equally well for applications in human eye tracking where head constraint is undesirable. Copyright © 2014. Published by Elsevier B.V.

  20. Destabilization of Human Balance Control by Static and Dynamic Head Tilts

    NASA Technical Reports Server (NTRS)

    Paloski, William H.; Wood, Scott J.; Feiveson, Alan H.; Black, F. Owen; Hwang, Emma Y.; Reschke, Millard F.

    2004-01-01

    To better understand the effects of varying head movement frequencies on human balance control, 12 healthy adult humans were studied during static and dynamic (0.14,0.33,0.6 Hz) head tilts of +/-30deg in the pitch and roll planes. Postural sway was measured during upright stance with eyes closed and altered somatosensory inputs provided by a computerized dynamic posturography (CDP) system. Subjects were able to maintain upright stance with static head tilts, although postural sway was increased during neck extension. Postural stability was decreased during dynamic head tilts, and the degree of destabilization varied directly with increasing frequency of head tilt. In the absence of vision and accurate foot support surface inputs, postural stability may be compromised during dynamic head tilts due to a decreased ability of the vestibular system to discern the orientation of gravity.

Top