Vignesh, S S; Jaya, V; Sasireka, B I; Sarathy, Kamala; Vanthana, M
2015-10-01
To estimate the prevalence and referral rates in well born and high risk babies using two step hearing screening protocol with Distortion Product Otoacoustic Emissions (DPOAE) and Automated Auditory Brainstem Response (AABR). A prospective study was carried out on 1405 neonates (983 well born babies and 422 high risk babies) who were screened during May 2013 to January 2015 at Institute of Obstetrics and Gynecology, Madras Medical College, Chennai. All neonates were screened using two step screening protocol. They were initially tested with DPOAE. Referred babies in DPOAE were screened with AABR subsequently. Among 1405 (100%) neonates 983 (69.96%) were well born babies and 422 (30.03%) were high risk babies. Total referral rate in DPOAE was found to be 311 (22.13%) among which 195 (13.87%) were well born babies and 116 (8.25%) were high risk babies. Out of 311 babies 31 (2.20%) babies were referred in AABR screening. In 31 babies referred in AABR 11(0.78%) were from well born group and 20 (1.42%) were from the high risk group. Further diagnostic evaluation of these babies, 2 (0.14%) were confirmed to have hearing loss. This study reveals, the prevalence of congenital hearing loss in our population is 1.42 per 1000 babies. Using two step protocol especially AABR along with DPOAE at the initial level of testing significantly reduces referral rates in new born screening programs. Also AABR decreases the false positive responses hence increasing the efficiency of screening program. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
A test protocol for assessing the hearing status of students with special needs.
Chen, Hsiao-Chuan; Wang, Nan-Mai; Chiu, Wen-Chen; Liu, Shu-Yu; Chang, Yi-Ping; Lin, Pei-Yu; Chung, King
2014-10-01
Individuals with disabilities are often reported to have a high prevalence of undetected hearing disorders/loss, but there is no standardized hearing test protocol for this population. The purposes of this study were (1) to examine the hearing status of students with special needs in Taiwan, and (2) to investigate the use of an on-site hearing test protocol that would adequately detect hearing problems in this population and reduce unnecessary referrals for off-site follow-up services. A total of 238 students enrolled in two schools for special education and one habilitation center participated in the study. Most students had intellectual disabilities and some also had additional syndromes or disorders. A hearing screening protocol including otoscopy, tympanometry, and distortion product otoacoustic emissions was administered to examine students' outer, middle, and inner ear functions, respectively. Pure tone tests were then administered as an on-site follow-up for those who failed or could not be tested using the screening protocol. Only 32.4% of students passed. When administered alone, the referral rate of otoscopy, tympanometry, and otoacoustic emissions were 38.7%, 46.0%, and 48.5%, respectively. The integration of these subtests revealed 52.1% of students needed follow-up services, 11.8% could not be tested, 2.5% had documented hearing loss, and 1.3% needed to be monitored because of negative middle ear pressure. The inclusion of pure tone audiometry increased the passing rate by 9.9% and provided information on hearing sensitivity for an additional 8.6% of students. Hearing assessments and regular hearing screening should be provided as an integral part of health care services for individuals with special needs because of high occurrences of excessive cerumen, middle ear dysfunction, and sensorineural hearing loss. The training of care-givers and teachers of students with special needs is encouraged so that they can help identify hearing problems and reduce the negative impact of hearing disorders and hearing loss. The screening protocol needs to include subtests that examine the status of different parts of their auditory system. The addition of pure tone audiometry as an on-site follow-up tool reduced the rate of off-site referrals and provided more information on hearing sensitivity. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Effective Identification of Functional Hearing Loss Using Behavioral Threshold Measures
ERIC Educational Resources Information Center
Schlauch, Robert S.; Koerner, Tess K.; Marshall, Lynne
2015-01-01
Purpose: Four functional hearing loss protocols were evaluated. Method: For each protocol, 30 participants feigned a hearing loss first on an audiogram and then for a screening test that began a threshold search from extreme levels (-10 or 90 dB HL). Two-tone and 3-tone protocols compared thresholds for ascending and descending tones for 2 (0.5…
Riga, Maria; Korres, George; Balatsouras, Dimitrios; Korres, Stavros
2010-07-01
Although occupational noise-induced hearing loss (NIHL) has become a major problem in industrialized societies, there is a notable lack of effective screening protocols to ensure its early diagnosis. The aim of this study was to detect a potential role of extended high frequency (EHF) audiometry in industrial hearing screening protocols. The population consisted of 151 persons, working for 8 hours daily in a noisy environment (90-110 dBA). The changes of hearing thresholds in industrial workers were analyzed, not only with respect to their age, as has been presented by previous studies, but also with respect to the duration of their previous employment. During the first 10 years of employment, the frequencies 12500, 14000 and 16000Hz were the only ones significantly affected. For the second decade of employment, thresholds were significantly elevated only at 2000 and 4000Hz. After exceeding 20 years of employment, the affected frequencies were 250, 500 and 1000Hz. The effects of age on hearing acuity were significant at all frequencies for the first 2 groups. EHF audiometry seems able to identify the first signs of NIHL, much earlier than conventional audiometry, and therefore may need to be implemented in the screening examinations especially of workers with less than 1 decade of employment. Hearing screening protocols could become more efficient by adjusting their frequency ranges according to the frequencies "at risk", which correspond to the duration of the workers' previous employment.
Jupiter, Tina
2009-12-01
To determine whether distortion product otoacoustic emissions (DPOAEs) could be used as a hearing screening tool with elderly individuals living independently, and to compare the utility of different screening protocols: (a) 3 pure-tone screening protocols consisting of 30 dB HL at 1, 2, and 3 kHz; 40 dB HL at 1, 2, and 3 kHz; or 40 dB HL at 1 and 2 kHz; (b) the Hearing Handicap Inventory for the Elderly-Screening version (HHIE-S); (c) pure tones at 40 dB HL at 1 and 2 kHz plus the HHIE-S; and (d) DPOAEs. A total of 106 elderly individuals age 65-91 years were screened using the above protocols. Pass/fail results showed that most individuals failed at 30 dB HL, followed by DPOAEs, the 40-dB HL protocols, the HHIE-S alone, and the combined pure-tone/HHIE-S protocol. All screening results were associated except the HHIE-S and 30 dB HL and the HHIE-S and DPOAEs. A McNemar analysis revealed that the differences between the correlated pass/fail results were significant except for the HHIE-S and 40 dB at 1 and 2 kHz. DPOAEs can be used to screen the elderly, with the advantage that individuals do not have to voluntarily respond to the test.
Mishra, Girish; Sharma, Yojana; Mehta, Kanishk; Patel, Gunjan
2013-04-01
Deafness is commonest curable childhood handicap. Most remedies and programmes don't address this issue at childhood level leading to detrimental impact on development of newborns. Aims and objectives are (A) screen all newborns for deafness and detect prevalence of deafness in children less than 2 years of age. and (B) assess efficacy of multi-staged OAE/ABR protocol for hearing screening. Non-randomized, prospective study from August 2008 to August 2011. All infants underwent a series of oto-acoustic emission (OAE) and final confirmatory auditory brainstem evoked response (ABR) audiometry. Finally, out of 1,101 children, 1,069 children passed the test while 12 children had impaired hearing after final testing, confirmed by ABR. Positive predictive value of OAE after multiple test increased to 100 %. OAE-ABR test series is effective in screening neonates and multiple tests reduce economic burden. High risk screening will miss nearly 50 % deaf children, thus universal screening is indispensable in picking early deafness.
Fall risk screening protocol for older hearing clinic patients.
Criter, Robin E; Honaker, Julie A
2017-10-01
The primary purposes of this study were (1) to describe measures that may contrast audiology patients who fall from those who do not fall and (2) to evaluate the clinical performance of measures that could be easily used for fall risk screening in a mainstream audiology hearing clinic. Cross-sectional study Study sample: Thirty-six community-dwelling audiology patient participants and 27 community-dwelling non-audiology patients over 60 years of age. The Hearing Handicap Inventory for the Elderly (HHIE) most accurately identified patients with a recent fall (sensitivity: 76.0%), while the Dizziness Handicap Inventory (DHI) most accurately identified patients without a recent fall (specificity: 90.9%). A combination of measures used in a protocol-including HHIE, DHI, number of medications, and the Timed Up and Go test-resulted in good, accurate identification of patients with or without a recent history of falls (92.0% sensitivity, 100% specificity). This study reports good sensitivity and excellent specificity for identifying patients with and without a recent history of falls when measures were combined into a screening protocol. Despite previously reported barriers, effective fall risk screenings may be performed in hearing clinic settings with measures often readily accessible to audiologists.
School hearing screening programme in the UK: practice and performance
Fonseca, S; Forsyth, H; Neary, W
2005-01-01
Background: Paediatric audiology services and screening programmes are currently under review. Aims and Methods: To investigate current practice and performance of the school hearing screening programme (SHSP) by means of a questionnaire. Results: SHSP was found to detect previously unrecognised hearing loss at low cost. Wide variation in practice was shown, and the majority of services had no computerised system for data collection. Conclusion: There is a need for nationally agreed protocols and quality assurance procedures. PMID:15665168
Kumar, U Ajith; Maruthy, Sandeep; Chandrakant, Vishwakarma
2009-03-01
Distortion product otoacoustic emissions are one form of evoked otoacoustic emissions. DPOAEs provide the frequency specific information about the hearing status in mid and high frequency regions. But in most screening protocols TEOAEs are preferred as it requires less time compared to DPOAE. This is because, in DPOAE each stimulus is presented one after the other and responses are analyzed. Grason and Stadler Incorporation 60 (GSI-60) offer simultaneous presentation of four sets of primary tones at a time and checks for the DPOAE. In this mode of presentation, all the pairs are presented at a time and following that response is extracted separately whereas, in sequential mode primaries are presented in orderly fashion one after the other. In this article simultaneous and sequential protocols were used to compare the Distortion product otoacoustic emission amplitude, noise floor and administration time in individuals with normal hearing and mild sensori-neural (SN) hearing loss. In simultaneous protocols four sets of primary tones (i.e. 8 tones) were presented together whereas, in sequential presentation mode one set of primary tones was presented each time. Simultaneous protocol was completed in less than half the time required for the completion of sequential protocol. Two techniques yielded similar results at frequencies above 1000 Hz only in normal hearing group. In SN hearing loss group simultaneous presentation yielded signifi cantly higher noise floors and distortion product amplitudes. This result challenges the use of simultaneous presentation technique in neonatal hearing screening programmes and on other pathologies. This discrepancy between two protocols may be due to some changes in biomechanical process in the cochlear and/or due to higher distortion/noise produced by the system during the simultaneous presentation mode.
Performance of two hearing screening protocols in NICU in Shanghai.
Xu, Zheng-Min; Cheng, Wen-Xia; Yang, Xiao-Lin
2011-10-01
To study the sensitivity and specificity of targeted neonatal hearing screening for the single-session distortion product otoacoustic emissions (DPOAE) technique and the combined DPOAE/automated auditory brain-stem response (AABR) technique. 3000 high-risk newborns were studied at Children's Hospital of Fudan University. They were required to take two different screening procedures separately. The first procedure consisted of DPOAE alone and the second consisted of DPOAE combined with the AABR. Based upon the etiology in high-risk babies, they were divided into four groups. In group I there were 670 very-low-birth-weight (VLBW) newborns (1340 ears), and in group II there were 890 preterm babies (1780 ears). 850 babies (1700 ears) suffered from hyperbilirubinemia in group III, whereas 790 babies (1580 ears) with asphyxia were in group IV. The babies in groups II, III, and IV came from the neonatal intensive-care unit (NICU) of our hospital. The study protocols consisted of the DPOAE alone and DPOAE combined with AABR hearing screening at an age of less than 1 month, and a diagnostic stage at the age of 2 months. With single-session DPOAE screening, the referral rate (8% of the NICU babies), the false-positive rate (4.96%) and the false-negative rate (0.8%) were higher. The different etiologies in NICU babies had significantly different referral rates (F-test, p<0.01). A 4.46% referral rate of hyperbilirubinemi babies was much lower. The combined DPOAE/AABR screening technique revealed a referral rate of 5.03%, a false-positive rate of 2% and a false-negative rate of 0.06%. The false-positive rate was well below the suggested 3% of the American Academy of Pediatric. Comparisons of the referral rate, false-positive rate and false-negative rate of two hearing screening protocols (DPOAE alone and combined DPOAE/AABR) revealed significant differences (t-test, p<0.05, p<0.01, p<0.01). 91 infants (3.03% of the NICU babies) who failed the combined DPOAE/AABR screening were confirmed on hearing impairment. Of 22 babies who passed DPOAE screening but failed the AABR screening had a severe to profound hearing loss based on classic ABR. These patients (24% of the NICU babies with hearing losses) with hyperbilirubinemia and asphyxia problems at newborn stage were diagnosed as auditory neuropathy based on evaluations of DPOAE screening passed, abnormal ABR and absent middle-ear muscle reflexes (MMR). Our study demonstrates the use of a combination of DPOAE and AABR testing ensures high sensitivity and acceptable specificity, and predict the AN profile in NICU babies. Our efforts identified 22 NICU babies with auditory neuropathy who hopefully will benefit from early remediation of their hearing deficit. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Current practice, accuracy, effectiveness and cost-effectiveness of the school entry hearing screen.
Bamford, J; Fortnum, H; Bristow, K; Smith, J; Vamvakas, G; Davies, L; Taylor, R; Watkin, P; Fonseca, S; Davis, A; Hind, S
2007-08-01
To describe and analyse in detail current practice of school entry hearing screening (SES) in the UK. Main electronic databases were searched up to May 2005. A national postal questionnaire survey was addressed to all leads for SES in the UK, considering current practice in terms of implementation, protocols, target population and performance data. Primary data from cohort studies in one area of London were examined. A systematic review of alternative SES tests, test performance and impact on outcomes was carried out. Finally, a review of published studies on costs, plus economic modelling of current and alternative programmes was prepared. The survey suggested that SES is used in most of England, Wales and Scotland; just over 10% of respondents have abandoned the screen; others are awaiting national guidance. Coverage of SES is variable, but is often over 90% for children in state schools. Referral rates are variable, with a median of about 8%. The test used for the screen is the pure tone sweep test but with wide variation in implementation, with differing frequencies, pass criteria and retest protocols; written examples of protocols were often poor and ambiguous. There is no national approach to data collection, audit and quality assurance, and there are variable approaches at local level. The screen is performed in less than ideal test conditions and resources are often limited, which has an impact on the quality of the screen. The primary cohort studies show that the prevalence of permanent childhood hearing loss continues to increase through infancy. Of the 3.47 in 1000 children with a permanent hearing loss at school screen age, 1.89 in 1000 required identification after the newborn screen. Newborn hearing screening is likely to reduce significantly the yield of SES for permanent bilateral and unilateral hearing impairments; yield had fallen from about 1.11 in 1000 before newborn screening to about 0.34 in 1000 for cohorts that had had newborn screening, of which only 0.07 in 1000 were unilateral impairments. Just under 20% of permanent moderate or greater bilateral, mild bilateral and unilateral impairments, known to services as 6-year-olds or older, remained to be identified around the time of school entry. No good-quality published comparative trials of alternative screens or tests for SES were identified and studies concerned with the relative accuracy of alternative tests are difficult to compare and often flawed by differing referral criteria and case definitions; with full pure tone audiometry as the reference test, the pure tone sweep test appears to have high sensitivity and high specificity for minimal, mild and greater hearing impairments, better than alternative tests for which evidence was identified. There is insufficient evidence regarding possible harm of the screen. There were no published studies identified that examined the possible effects of SES on longer term outcomes. No good-quality published economic evaluations of SES were identified and a universal SES based on pure tone sweep tests was associated with higher costs and slightly higher quality-adjusted life-years (QALYs) compared with no screen and other screen alternatives; the incremental cost-effectiveness ratio for such a screen is around 2500 pounds per QALY gained; the range of expected costs, QALYs and net benefits was broad, indicating a considerable degree of uncertainty. Targeted screening could be more cost-effective than universal school entry screening; however, the lack of primary data and the wide limits for variables in the modelling mean that any conclusions must be considered indicative and exploratory only. A national screening programme for permanent hearing impairment at school entry meets all but three of the criteria for a screening programme, but at least six criteria are not met for screening for temporary hearing impairment. The lack of good-quality evidence in this area remains a serious problem. Services should improve quality and audit screen performance for identification of previously unknown permanent hearing impairment, pending evidence-based policy decisions based on the research recommendations. Further research is needed into a number of important areas including the evaluation of an agreed national protocol for services delivering SES to make future studies and audits of screen performance more directly comparable.
Navarro-Locsin, C Gretchen
2003-01-01
Various centers around the world have implemented and evaluated universal hearing screening programs as a response to the US National Institute of Health policy statement on early identification of hearing loss. Several well conducted clinical trials have been devised to examine and evaluate various factors relevant to establishing a UNHS program. This paper aims to describe some of these factors and analyze their applications and implications for a UNHS program for a developing country in the Asia-Pacific Region. Specifically, three main issues will be discussed: hospital vs community based programs, choice of technology, and choice of screening protocol.
Early hearing detection and intervention: 2010 CODEPEH recommendation.
Trinidad-Ramos, Germán; de Aguilar, Valentín Alzina; Jaudenes-Casaubón, Carmen; Núñez-Batalla, Faustino; Sequí-Canet, José Miguel
2010-01-01
Newborn hearing screening is currently performed routinely in many regional health-care systems in Spain. Despite the remarkable expansion in newborn hearing screening since 2000, its feasibility and the benefits of early identification and intervention, many major challenges still remain. In this article, the Committee for the Early Detection of Hearing Loss (Comisión para la Detección Precoz de la Hipoacusia, CODEPEH) updates the recommendations that are considered important for the future development of early hearing detection and intervention (EDHI) systems in the following points: 1. Screening protocols: Separate protocols are recommended for NICU (Neonatal Intensive Care Units) and well-infant nurseries. 2. Diagnostic audiology evaluation. Professionals with skills and expertise in evaluating newborn and young infants should provide diagnosis, selection and fitting of amplification devices. 3. Medical evaluation. Risk factors for congenital and acquired hearing loss have been combined in a single list rather than grouped by time of onset. A stepwise diagnostic paradigm is diagnostically more efficient and cost-effective than a simultaneous testing approach. 4. Early intervention and surveillance. All individuals providing services to infants with hearing loss should have specialized training and expertise in the development of audition, speech and language. Regular surveillance should be performed on developmental milestones, auditory skills, parental concerns, and middle ear status. 5. Quality control. Data management as part of an integrated system is important to monitor and improve the quality of EDHI services. 2009 Elsevier España, S.L. All rights reserved.
Kanji, Amisha; Khoza-Shangase, Katijah
2012-12-01
The current study aimed at determining the type and frequency of high-risk factors for hearing loss in a group of very-low-birth-weight (VLBW) neonates in a tertiary hospital in South Africa with the objective of collating evidence that could be used in arguing for or against revisiting targeted hearing screening in developing countries. Furthermore, the study aimed at investigating the relationship between the identified high-risk factors and hearing screening results. In a retrospective data review design, data were collated from files from the VLBW project; this included hearing screening records, as well as records from participant medical and audiology files. Records of 86 neonates with birth weights ranging between 680 g and 1500 g were reviewed. Findings indicated that neonatal jaundice, exposure to human immunodeficiency virus (HIV), mechanical or assisted ventilation, and neonatal intensive care unit stay greater than 48 hours were the most frequently occurring high-risk factors for hearing loss in the current sample. These factors are consistent with those listed in the high-risk register of the Health Professions Council of South Africa for the South African context. Findings confirm the complexity of risk factors, and the influence that a variety of factors such as poor follow-up or return rate might have on the implementation of early hearing detection and intervention. The importance of establishing context-specific risk factors for effective implementation of targeted screening protocols where niversal newborn hearing screening is not yet a reality was highlighted by the current study.
Assessment of the efficacy of a hearing screening program for college students.
Taylor, Emily J; Emanuel, Diana C
2013-01-01
The Towson University (TU) Speech-Language-Hearing Center (SLHC) conducts annual hearing screenings for college students entering education or health-care professions. Hearing is screened in therapy rooms, and students who fail the screening are rescreened in a sound-treated booth. Students who fail the rescreening are referred for a comprehensive audiological assessment, which is offered at no cost to students at the SLHC. The purpose of this study was to examine the efficacy of the hearing screening program, to report trends in hearing screening statistics for the college student population, and to make recommendations regarding ways universities can optimize hearing screening programs. The study included retrospective and prospective portions. Hearing screening records were reviewed from 1999 to 2011. The prospective study involved recruiting students to participate in diagnostic testing following the hearing screening and measuring background noise levels in the therapy rooms. Hearing screening records from 1999 to 2011 were reviewed. In addition, during the three-day fall 2011 hearing screenings, 80 students were selected to participate in diagnostic testing. Data from the retrospective review were used to determine positive predictive value (PPV) between screening and rescreening. Return rates were also examined. For the prospective study, pure tone threshold results were compared to screening results to determine sensitivity, specificity, and PPV. The retrospective file review indicated that the hearing screening in the therapy room had poor PPV compared with the rescreening in the sound booth. Specifically, if a student failed the screening, they had only a 49% chance of failing the rescreening. This may have been due to background noise, as the prospective study found noise levels were higher than allowed by American National Standards Institute (ANSI) standard. Only a third of students referred for diagnostic testing from 1999 to 2010 returned for recommended diagnostic testing. For the prospective study, specificity and sensitivity were good when considering hearing loss present at the same frequencies as those screened (1000, 2000, 4000 Hz) but poor in comparison to hearing loss overall. The screening missed many students with a high frequency notch, which was most prevalent at 6000 Hz. The prevalence of a high frequency notch was 21 and 51%, using two different criteria for establishing the presence of a notch. If college hearing screenings are conducted in rooms that are not sound treated, poor PPV should be expected; thus, an immediate second stage rescreening for failures should be conducted in a sound booth. Hearing screenings limited to 1000, 2000, and 4000 Hz will miss many cases of hearing loss in the college-age population. College hearing screening program directors should carefully consider the purpose of the screening and adjust screening protocol, such as adding 6000 Hz and a question about noise exposure, in order to identify early signs of noise-induced hearing loss in college students. Programs should focus on ways to promote high return for follow-up rates. Estimates of prevalence of a high-frequency audiometric notch are highly dependent on the criteria used to define a notch. American Academy of Audiology.
Cognition and screening for hearing loss in nursing home residents.
Jupiter, Tina
2012-10-01
To compare hearing screening results using pure tones and distortion product otoacoustic emissions (DPOAEs) with nursing home residents who have dementia and explore the relationship of hearing impairment and cognitive function using the Mini- Mental Status Evaluation (MMSE). A correlational design was implemented to evaluate residents in a large inner city nursing home. One hundred one nursing home residents 65-108 years. DPOAEs and pure tone screenings were conducted at 30 dB HL and 40 dB HL at 1, 2, and 3 kHz. Pure tone thresholds at 1, 2, and 3 kHz were obtained. The MMSE was administered to all participants. Results showed that all residents failed the DPOAE screen, 97.1% failed at 30 dB HL, and 90.0% failed at 40 dB HL. Kendall's tau, phi correlation, linear by linear association, and χ(2) results indicated no significant relationship for any of the screening protocols and cognitive status other than a significant finding with left ear screening at 40 dB HL. Logistic regression analysis indicated that individuals who passed the screen had better MMSE scores. Results of the t test and Mann-Whitney U test revealed a significant difference in cognitive function for residents with a mild hearing loss compared with those with a more significant hearing loss. For screening nursing home residents, 40 dB HL screening level or DPOAEs can be used. The significant finding that residents with greater than a mild hearing loss have poorer cognitive function reinforces the importance of identifying residents with a hearing loss and providing rehabilitation and follow-up. Copyright © 2012 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.
Olusanya, Bolajoko O; Akinyemi, Oladele O
2009-02-23
Universal newborn hearing screening is now considered an essential public health care for the early detection of disabling life-long childhood hearing impairment globally. However, like any health interventions in early childhood, parental support and participation is essential for achieving satisfactory uptake of services. This study set out to determine maternal/infant socio-demographic factors associated with follow-up compliance in community-based infant hearing screening programmes in a developing country. After health educational/counselling sessions, infants attending routine childhood immunisation clinics at four primary care centres were enrolled into a two-stage infant hearing screening programme consisting of a first-stage screening with transient-evoked otoacoustic emissions and second-stage screening with automated auditory brainstem response. Infants referred after the second-stage screening were scheduled for diagnostic evaluation within three months. Maternal and infant factors associated with completion of the hearing screening protocol were determined with multivariable logistic regression analysis. No mother declined participation during the study period. A total of 285 out of 2,003 eligible infants were referred after the first-stage screening out of which 148 (51.9%) did not return for the second-stage, while 32 (39.0%) of the 82 infants scheduled for diagnostic evaluation defaulted. Mothers who delivered outside hospitals were significantly more likely to return for follow-up screening than those who delivered in hospitals (Odds ratio: 1.62; 95% confidence intervals: 0.98 - 2.70; p = 0.062). No other factors correlated with follow-up compliance for screening and diagnostic services. Place of delivery was the only factor that correlated albeit marginally with infant hearing screening compliance in this population. The likely influence of issues such as the number of return visits for follow-up services, ineffective tracking system and the prevailing unfavourable cultural perception towards childhood deafness on non-compliance independently or through these factors warrant further investigation.
Olusanya, Bolajoko O; Akinyemi, Oladele O
2009-01-01
Background Universal newborn hearing screening is now considered an essential public health care for the early detection of disabling life-long childhood hearing impairment globally. However, like any health interventions in early childhood, parental support and participation is essential for achieving satisfactory uptake of services. This study set out to determine maternal/infant socio-demographic factors associated with follow-up compliance in community-based infant hearing screening programmes in a developing country. Methods After health educational/counselling sessions, infants attending routine childhood immunisation clinics at four primary care centres were enrolled into a two-stage infant hearing screening programme consisting of a first-stage screening with transient-evoked otoacoustic emissions and second-stage screening with automated auditory brainstem response. Infants referred after the second-stage screening were scheduled for diagnostic evaluation within three months. Maternal and infant factors associated with completion of the hearing screening protocol were determined with multivariable logistic regression analysis. Results No mother declined participation during the study period. A total of 285 out of 2,003 eligible infants were referred after the first-stage screening out of which 148 (51.9%) did not return for the second-stage, while 32 (39.0%) of the 82 infants scheduled for diagnostic evaluation defaulted. Mothers who delivered outside hospitals were significantly more likely to return for follow-up screening than those who delivered in hospitals (Odds ratio: 1.62; 95% confidence intervals: 0.98 – 2.70; p = 0.062). No other factors correlated with follow-up compliance for screening and diagnostic services. Conclusion Place of delivery was the only factor that correlated albeit marginally with infant hearing screening compliance in this population. The likely influence of issues such as the number of return visits for follow-up services, ineffective tracking system and the prevailing unfavourable cultural perception towards childhood deafness on non-compliance independently or through these factors warrant further investigation. PMID:19236718
Narrative review of EHDI in South Africa
Storbeck, Claudine
2015-01-01
Background With 17 babies born with hearing loss every day in South Africa, there is a pressing need for systematic Early Hearing Detection and Intervention (EHDI) services. Progress is being made in offering newborn hearing screening and studies have been conducted to document these processes within South Africa. However, due to the lack of a national and holistic overview of EHDI services to date, an accurate picture of the current status of EHDI within the South African context is required. Objective To document and profile what has been published within the field of EHDI in South Africa over the last two decades (Jan 1995–Sept 2014) in order to gain a comprehensive overview of the current status and practice of screening and diagnosis in the field of paediatric hearing loss. Method A narrative review of peer-reviewed articles related to EHDI in South Africa was conducted by searching the EBSCOHOST, SCOPUS and JSTOR databases for the period January 1995 to September 2014. Results Results indicate that over the last two decades research and publications in the field of EHDI have increased considerably. These publications have revealed extensive knowledge related to paediatric hearing screening and intervention services in South Africa; however, this knowledge seems to be limited primarily to the provinces of Gauteng and the Western Cape. Furthermore, studies pertaining to diagnosis have revealed that, although much has been written on the scientific aspects on tools for diagnosis of hearing loss, there is a lack of comprehensive information on diagnostic protocols and procedures. Conclusion Despite the clear progress being made in South Africa in the field of early hearing detection and intervention, there is a need for comprehensive studies on protocols and procedures in diagnosing paediatric hearing loss. Finally, the narrative review revealed a clear need to ensure that development and growth in the field of EHDI is a national priority and extends beyond the two provinces currently showing growth.
Contralateral ear occlusion for improving the reliability of otoacoustic emission screening tests.
Papsin, Emily; Harrison, Adrienne L; Carraro, Mattia; Harrison, Robert V
2014-01-01
Newborn hearing screening is an established healthcare standard in many countries and testing is feasible using otoacoustic emission (OAE) recording. It is well documented that OAEs can be suppressed by acoustic stimulation of the ear contralateral to the test ear. In clinical otoacoustic emission testing carried out in a sound attenuating booth, ambient noise levels are low such that the efferent system is not activated. However in newborn hearing screening, OAEs are often recorded in hospital or clinic environments, where ambient noise levels can be 60-70 dB SPL. Thus, results in the test ear can be influenced by ambient noise stimulating the opposite ear. Surprisingly, in hearing screening protocols there are no recommendations for avoiding contralateral suppression, that is, protecting the opposite ear from noise by blocking the ear canal. In the present study we have compared transient evoked and distortion product OAEs measured with and without contralateral ear plugging, in environmental settings with ambient noise levels <25 dB SPL, 45 dB SPL, and 55 dB SPL. We found out that without contralateral ear occlusion, ambient noise levels above 55 dB SPL can significantly attenuate OAE signals. We strongly suggest contralateral ear occlusion in OAE based hearing screening in noisy environments.
Núñez-Batalla, Faustino; Carro-Fernández, Pilar; Antuña-León, María Eva; González-Trelles, Teresa
2008-03-01
Hyperbilirubinaemia is a neonatal risk factor that has been proved to be associated with sensorineural hearing loss. A high concentration of unconjugated bilirubin place newborn children at risk of suffering toxic effects, including hypoacusia. Review of the newborn screening results with a diagnosis of pathological hyperbilirubinaemia as part of a hearing-loss early detection protocol in the general population based on otoemissions and evoked potentials. Retrospective study of 21 590 newborn children screened between 2002 and 2006. The selection criteria for defining pathological hyperbilirubinaemia were bilirubin concentrations in excess of 14 mg/dL in pre-term infants and 20 mg/dL in full-term babies. The Universal Neonatal Hearing Screening Programme is a two-phase protocol in which all children are initially subjected to a transient otoacoustic emissions test (TOAE). Children presenting risk factors associated with auditory neuropathy were always given brainstem auditory evoked potentials (BAEP). The patients identified as having severe hyperbilirubinaemia in the neonatal period numbered 109 (0.5 %) and 96 of these (88.07 %) passed the otoacoustic emissions test at the first attempt and 13 (11.93 %) did not; 11 of the 13 children in whom the otoacoustic emissions test was repeated passed it successfully. The 2 children who failed to pass the otoacoustic emissions test has normal BAEP results; 3 (2.75 %) of the newborn infants who passed the TOAE test did not pass the BAEP. Hyperbilirubinaemia values previously considered safe may harm the hearing system and give rise to isolated problems in auditory processing without being associated with other signs of classical kernicterus. Our results show that hyperbilirubinaemia-related auditory neuropathy reveals changes over time in the audiometric outcomes.
McGilton, Katherine S; Höbler, Fiona; Campos, Jennifer; Dupuis, Kate; Labreche, Tammy; Guthrie, Dawn M; Jarry, Jonathan; Singh, Gurjit; Wittich, Walter
2016-01-01
Introduction Hearing and vision loss among long-term care (LTC) residents with dementia frequently goes unnoticed and untreated. Despite negative consequences for these residents, there is little information available about their sensory abilities and care assessments and practices seldom take these abilities or accessibility needs into account. Without adequate knowledge regarding such sensory loss, it is difficult for LTC staff to determine the level of an individual's residual basic competence for communication and independent functioning. We will conduct a scoping review to identify the screening measures used in research and clinical contexts that test hearing and vision in adults aged over 65 years with dementia, aiming to: (1) provide an overview of hearing and vision screening in older adults with dementia; and (2) evaluate the sensibility of the screening tools. Methods and analysis This scoping review will be conducted using the framework by Arksey and O'Malley and furthered by methodological enhancements from cited researchers. We will conduct electronic database searches in CENTRAL, CINAHL, EMBASE, MEDLINE and PsycINFO. We will also carry out a ‘grey literature’ search for studies or materials not formally published, both online and through interview discussions with healthcare professionals and research clinicians working in the field. Our aim is to find new and existing hearing and vision screening measures used in research and by clinical professionals of optometry and audiology. Abstracts will be independently reviewed twice for acceptance by a multidisciplinary team of researchers and research clinicians. Ethics and dissemination This review will inform health professionals working with this growing population. With the review findings, we aim to develop a toolkit and an algorithmic process to select the most appropriate hearing and vision screening assessments for LTC residents with dementia that will facilitate accurate testing and can inform care planning, thereby improving residents’ quality of life. PMID:27466242
McGilton, Katherine S; Höbler, Fiona; Campos, Jennifer; Dupuis, Kate; Labreche, Tammy; Guthrie, Dawn M; Jarry, Jonathan; Singh, Gurjit; Wittich, Walter
2016-07-26
Hearing and vision loss among long-term care (LTC) residents with dementia frequently goes unnoticed and untreated. Despite negative consequences for these residents, there is little information available about their sensory abilities and care assessments and practices seldom take these abilities or accessibility needs into account. Without adequate knowledge regarding such sensory loss, it is difficult for LTC staff to determine the level of an individual's residual basic competence for communication and independent functioning. We will conduct a scoping review to identify the screening measures used in research and clinical contexts that test hearing and vision in adults aged over 65 years with dementia, aiming to: (1) provide an overview of hearing and vision screening in older adults with dementia; and (2) evaluate the sensibility of the screening tools. This scoping review will be conducted using the framework by Arksey and O'Malley and furthered by methodological enhancements from cited researchers. We will conduct electronic database searches in CENTRAL, CINAHL, EMBASE, MEDLINE and PsycINFO. We will also carry out a 'grey literature' search for studies or materials not formally published, both online and through interview discussions with healthcare professionals and research clinicians working in the field. Our aim is to find new and existing hearing and vision screening measures used in research and by clinical professionals of optometry and audiology. Abstracts will be independently reviewed twice for acceptance by a multidisciplinary team of researchers and research clinicians. This review will inform health professionals working with this growing population. With the review findings, we aim to develop a toolkit and an algorithmic process to select the most appropriate hearing and vision screening assessments for LTC residents with dementia that will facilitate accurate testing and can inform care planning, thereby improving residents' quality of life. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Rojas, Jorge A; Bernal, Jaime E; García, Mary A; Zarante, Ignacio; Ramírez, Natalia; Bernal, Constanza; Gelvez, Nancy; Tamayo, Marta L
2014-10-01
The aim of this study was to investigate the characteristics and performance of transient evoked oto-acoustic emission (TEOAE) hearing screening in newborns in Colombia, and analyze all possible variables and factors affecting the results. An observational, descriptive and retrospective study with bivariate analysis was performed. The study population consisted of 56,822 newborns evaluated at the private institution, PREGEN. TEOAE testing was carried out as a pediatric hearing screening test from December 2003 to March 2012. The database from PREGEN was revised, and the protocol for evaluation included the same screening test performed twice. Demographic characteristics were recorded and the newborn's background was evaluated. Basic statistics of the qualitative and quantitative variables, and statistical analysis were obtained using the chi-square test. Of the 56,822 records examined, 0.28% were classed as abnormal, which corresponded to a prevalence of 1 in 350. In the screened newborns, 0.08% had a major abnormality or other clinical condition diagnosed, and 0.29% reported a family history of hearing loss. A prevalence of 6.7 in 10,000 was obtained for microtia, which is similar to the 6.4 in 10,000 previously reported in Colombia (database of the Latin-American Collaborative Study of Congenital Malformations - ECLAMC). Statistical analysis demonstrated an association between presenting with a major anomaly and a higher frequency of abnormal results on both TEOAE tests. Newborns in Colombia do not currently undergo screening for the early detection of hearing impairment. The results from this study suggest TEOAE screening tests, when performed twice, are able to detect hearing abnormalities in newborns. This highlights the need to improve the long-term evaluation and monitoring of patients in Colombia through diagnostic tests, and to provide tests that are both sensitive and specific. Furthermore, the use of TEOAE screening is justified by the favorable cost: benefit ratio demonstrated in many countries worldwide. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Labanca, Ludimila; Guimarães, Fernando Sales; Costa-Guarisco, Letícia Pimenta; Couto, Erica de Araújo Brandão; Gonçalves, Denise Utsch
2017-11-01
Given the high prevalence of presbycusis and its detrimental effect on quality of life, screening tests can be useful tools for detecting hearing loss in primary care settings. This study therefore aimed to determine the accuracy and reproducibility of the whispered voice test as a screening method for detecting hearing impairment in older people. This cross-sectional study was carried out with 210 older adults aged between 60 and 97 years who underwent the whispered voice test employing ten different phrases and using audiometry as a reference test. Sensitivity, specificity and positive and negative predictive values were calculated and accuracy was measured by calculating the area under the ROC curve. The test was repeated on 20% of the ears by a second examiner to assess inter-examiner reproducibility (IER). The words and phrases that showed the highest area under the curve (AUC) and IER values were: "shoe" (AUC = 0.918; IER = 0.877), "window" (AUC = 0.917; IER = 0.869), "it looks like it's going to rain" (AUC = 0.911; IER = 0.810), and "the bus is late" (AUC = 0.900; IER = 0.810), demonstrating that the whispered voice test is a useful screening tool for detecting hearing loss among older people. It is proposed that these words and phrases should be incorporated into the whispered voice test protocol.
Clinical Validity of hearScreen™ Smartphone Hearing Screening for School Children.
Mahomed-Asmail, Faheema; Swanepoel, De Wet; Eikelboom, Robert H; Myburgh, Hermanus C; Hall, James
2016-01-01
The study aimed to determine the validity of a smartphone hearing screening technology (hearScreen™) compared with conventional screening audiometry in terms of (1) sensitivity and specificity, (2) referral rate, and (3) test time. One thousand and seventy school-age children in grades 1 to 3 (8 ± 1.1 average years) were recruited from five public schools. Children were screened twice, once using conventional audiometry and once with the smartphone hearing screening. Screening was conducted in a counterbalanced sequence, alternating initial screen between conventional or smartphone hearing screening. No statistically significant difference in performance between techniques was noted, with smartphone screening demonstrating equivalent sensitivity (75.0%) and specificity (98.5%) to conventional screening audiometry. While referral rates were lower with the smartphone screening (3.2 vs. 4.6%), it was not significantly different (p > 0.05). Smartphone screening (hearScreen™) was 12.3% faster than conventional screening. Smartphone hearing screening using the hearScreen™ application is accurate and time efficient.
Cutler, Jodi; Lenzi, Giovanni; Berrettini, Stefano; Martini, Alessandro; Martinelli, Stefano
2012-10-01
The establishment of the Italian Pediatric Federation Newborn Hearing Screening Network and the Italian Society of Neonatology Infant Hearing Study Group is the result of an international collaboration between Parents and Medical Professionals in order to promote an effective model in developing Early Hearing Detection Intervention Programs that recognize the role of parents as partners in the process. Among other factors, one important component frequently underestimated in most early intervention programs, both in the USA and other countries, involves the role of parental involvement within the Early Hearing Detection Intervention (EHDI) process. When a parent receives the news of their child's hearing loss, reactions may include, but are not limited to denial, grief, guilt, shame, fear and impotency. A parent may begin to ask certain questions: How do we know if the professionals in our children's lives are capable, educated, trained, up to date in their chosen fields of expertise? Do they respect our children and us as parents? Do they understand the needs of children who are deaf or hard of hearing? A life-long health professional - parental collaboration begins at the moment of the diagnosis of that child. When analyzing the habilitation process of a deaf child, the relationship between health professionals and the crucial role of parents in raising that child is a 50-50 shared responsibility. An objective of EHDI programs must be to empower parents by providing support from the beginning of the process. Distributing informative literature regarding the newborn hearing screening process and providing parents with access to resources such as parental support groups upon diagnosis equips parents with the tools necessary to immediately begin advocating for their children. The Italian Federation Pediatric Audiology Network was created by combining the parental perspective and medical protocols in order to establish the roots for stronger EHDI programs.
Watson, Charles S; Kidd, Gary R; Miller, James D; Smits, Cas; Humes, Larry E
2012-01-01
An estimated 36 million US citizens have impaired hearing, but nearly half of them have never had a hearing test. As noted by a recent National Institutes of Health/National Institute on Deafness and Other Communication Disorders (NIH/NIDCD) Working Group, "In the United States (in contrast to many other nations) there are no readily accessible low cost hearing screening programs…" (Donahue et al, 2010, p. 2). Since 2004, telephone administered screening tests utilizing three-digit sequences presented in noise have been developed, validated, and implemented in seven countries. Each of these tests has been based on a test protocol conceived by Smits and colleagues in The Netherlands. Investigators from Communication Disorders Technology, Inc., Indiana University, and VU University Medical Center of Amsterdam agreed to collaborate in the development and validation of a screening test for hearing impairment suitable for delivery over the telephone, for use in the United States. This test, utilizing spoken three-digit sequences (triplets), was to be based on the design of Smits and his colleagues. A version of the digits-in-noise test was developed utilizing digit triplets spoken in Middle American dialect. The stimuli were individually adjusted to speech-to-noise ratio (SNR) values yielding 50% correct identification, on the basis of data collected from a group of 10 young adult listeners with normal hearing. A final set of 64 homogeneous stimuli were selected from an original 160 recorded triplets. Each test consisted of a series of 40 triplets drawn at random, presented in a noise background. The SNR threshold for 50% correct identification of the triplets was determined by a one-down, one-up adaptive procedure. The test was implemented by telephone, and administered to listeners with varying levels of hearing impairment. The listeners were then evaluated with pure-tone tests and other audiometric measures as clinically appropriate. Ninety participants included 72 who were volunteers from the regular client population at the Indiana University Hearing Clinic, and 18 who were recruited with a newspaper ad offering a free hearing test. Of the 90 participants, 49 were later determined to have mean pure-tone thresholds greater than 20 dB hearing level (HL). The primary data analyses were correlations between telephone test thresholds and other measures, including pure-tone thresholds and speech recognition tests, collected for the same participants. The correlation between the telephone test and pure-tone thresholds (r = 0.74) was within the range of correlations observed with successful telephone screening tests in use in other countries. Thresholds based on the average of only 21 trials (trials five through 25 of the 40-trial tracking history) yielded sensitivity and specificity values of 0.80 and 0.83, respectively, using pure-tone average((0.5, 1.0, 2.0 kHz)) >20 dB HL as the criterion measure. This US version of the digits-in-noise telephone screening test is sufficiently valid to be implemented for use by the general public. Its properties are quite similar to those telephone screening tests currently in use in most European countries. Telephone tests provide efficient, easy to use, and valid screening for functional hearing impairment. The results of this test are a reasonable basis for advising those who fail to seek a comprehensive hearing evaluation by an audiologist. American Academy of Audiology.
GIUNTINI, G.; NICASTRO, R.; CIABOTTI, A.; BRUSCHINI, L.; BERRETTINI, S.
2016-01-01
SUMMARY The implementation of regional protocols for newborn hearing screening and early audiologic diagnosis represent the first step of the entire diagnostic, rehabilitative and prosthetic programme for children with permanent hearing impairment. The maximum benefit of early diagnosis can indeed be obtained only by prompt rehabilitation aimed at fostering the child's communicative, linguistic and cognitive development. Within the framework of the CMM 2013 project of the Ministry of Health entitled "Preventing Communication Disorders: a Regional Program for Early Identification, Intervention and Care of Hearing Impaired Children", the problems concerning the promotion of the global development of children with PHI throughan early rehabilitation project based on shared knowledge and scientific evidence. In this project, our specific aim was to define the features and modes of access to a precise and specialised rehabilitation project for the small hearing-impaired child within three months from audiologic diagnosis. Three main recommendations relative to assessment and rehabilitation aspects of early care emerged from the study. PMID:27054391
Procedures for central auditory processing screening in schoolchildren.
Carvalho, Nádia Giulian de; Ubiali, Thalita; Amaral, Maria Isabel Ramos do; Santos, Maria Francisca Colella
2018-03-22
Central auditory processing screening in schoolchildren has led to debates in literature, both regarding the protocol to be used and the importance of actions aimed at prevention and promotion of auditory health. Defining effective screening procedures for central auditory processing is a challenge in Audiology. This study aimed to analyze the scientific research on central auditory processing screening and discuss the effectiveness of the procedures utilized. A search was performed in the SciELO and PUBMed databases by two researchers. The descriptors used in Portuguese and English were: auditory processing, screening, hearing, auditory perception, children, auditory tests and their respective terms in Portuguese. original articles involving schoolchildren, auditory screening of central auditory skills and articles in Portuguese or English. studies with adult and/or neonatal populations, peripheral auditory screening only, and duplicate articles. After applying the described criteria, 11 articles were included. At the international level, central auditory processing screening methods used were: screening test for auditory processing disorder and its revised version, screening test for auditory processing, scale of auditory behaviors, children's auditory performance scale and Feather Squadron. In the Brazilian scenario, the procedures used were the simplified auditory processing assessment and Zaidan's battery of tests. At the international level, the screening test for auditory processing and Feather Squadron batteries stand out as the most comprehensive evaluation of hearing skills. At the national level, there is a paucity of studies that use methods evaluating more than four skills, and are normalized by age group. The use of simplified auditory processing assessment and questionnaires can be complementary in the search for an easy access and low-cost alternative in the auditory screening of Brazilian schoolchildren. Interactive tools should be proposed, that allow the selection of as many hearing skills as possible, validated by comparison with the battery of tests used in the diagnosis. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Weber, Brittany C; Whitlock, Scott M; He, Kaidi; Kimbrell, Blake S; Derkay, Craig S
2018-04-12
To evaluate the prevalence of middle ear disease in infants referred for failed newborn hearing screening (NBHS) and to review patient outcomes after intervention in order to propose an evidence-based protocol for management of newborns with otitis media with effusion (OME) who fail NBHS. 85 infants with suspected middle ear pathology were retrospectively reviewed after referral for failed NBHS. All subjects underwent a diagnostic microscopic exam with myringotomy with or without placement of a ventilation tube in the presence of a middle ear effusion and had intra-operative auditory brainstem response (ABR) testing or testing at a later date. At the initial office visit, a normal middle ear space bilaterally was documented in 5 babies (6%), 29/85 (34%) had an equivocal exam while 51/85 (60%) had at least a unilateral OME. Myringotomy with or without tube placement due to presence of an effusion was performed on 65/85 (76%) neonates. Normal hearing was established in 17/85 (20%) after intervention, avoiding the need for any further audiologic workup. Bilateral or unilateral sensorineural hearing loss (SNHL) or mixed hearing loss was noted in 54/85 (64%) and these children were referred for amplification. Initially observation with follow up outpatient visits was initiated in 27/85 (32%) however, only 3/27 (11%) resolved with watchful waiting and 24/27 (89%) ultimately required at least unilateral tube placement due to OME and 14/24 (59%) were found to have at least a unilateral mixed or SNHL. An effective initial management plan for children with suspected middle ear pathology and failed NBHS is diagnostic operative microscopy with placement of a ventilation tube in the presence of a MEE along with either intra-operative ABR or close follow-up ABR. This allows for the identification and treatment of babies with a conductive component due to OME, accurate diagnosing of an underlying SNHL component and for prompt aural rehabilitation. Copyright © 2018 Elsevier Inc. All rights reserved.
Allen, Marvin; Allen, John; Naseri, Take; Gardner, Rebecca; Tolley, Dennis; Allen, Lori
2017-10-01
Echocardiography has been proposed as a method to screen children for rheumatic heart disease. The World Heart Federation has established guidelines for echocardiographic screening. In this study, we describe a rapid echocardiogram screening protocol according to the World Heart Federation guidelines in Samoa, endemic for rheumatic heart disease. We performed echocardiogram screening in schoolchildren in Samoa between 2013 and 2015. A brief screening echocardiogram was performed on all students. Children with predefined criteria suspicious for rheumatic hear diseases were referred for a more comprehensive echocardiogram. Complete echocardiograms were classified according to the World Heart Federation guidelines and severity of valve disease. Echocardiographic screening was performed on 11,434 children, with a mean age of 10.2 years; 51% of them were females. A total of 558 (4.8%) children underwent comprehensive echocardiography, including 49 students who were randomly selected as controls. Definite rheumatic heart disease was observed in 115 students (10.0 per 1000): 92 students were classified as borderline (8.0 per 1000) and 23 with CHD. Advanced disease was identified in 50 students (4.4 per 1000): 15 with severe mitral regurgitation, five with severe aortic regurgitation, 11 with mitral stenoses, and 19 with mitral and aortic valve disease. We successfully applied a rapid echocardiographic screening protocol to a large number of students over a short time period - 28 days of screening over a 3-year time period - to identify a high prevalence of rheumatic heart disease. We also reported a significantly higher rate of advanced disease compared with previously published echocardiographic screening programmes.
Ching, Teresa Y. C.; Zhang, Vicky W.; Hou, Sanna; Van Buynder, Patricia
2016-01-01
Hearing loss in children is detected soon after birth via newborn hearing screening. Procedures for early hearing assessment and hearing aid fitting are well established, but methods for evaluating the effectiveness of amplification for young children are limited. One promising approach to validating hearing aid fittings is to measure cortical auditory evoked potentials (CAEPs). This article provides first a brief overview of reports on the use of CAEPs for evaluation of hearing aids. Second, a study that measured CAEPs to evaluate nonlinear frequency compression (NLFC) in hearing aids for 27 children (between 6.1 and 16.8 years old) who have mild to severe hearing loss is reported. There was no significant difference in aided sensation level or the detection of CAEPs for /g/ between NLFC on and off conditions. The activation of NLFC was associated with a significant increase in aided sensation levels for /t/ and /s/. It also was associated with an increase in detection of CAEPs for /t/ and /s/. The findings support the use of CAEPs for checking audibility provided by hearing aids. Based on the current data, a clinical protocol for using CAEPs to validate audibility with amplification is presented. PMID:27587920
Using benefit-cost ratio to select Universal Newborn Hearing Screening test criteria.
Porter, Heather L; Neely, Stephen T; Gorga, Michael P
2009-08-01
Current protocols presumably use criteria that are chosen on the basis of the sensitivity and specificity rates they produce. Such an approach emphasizes test performance but does not include societal implications of the benefit of early identification. The purpose of the present analysis was to evaluate an approach to selecting criteria for use in Universal Newborn Hearing Screening (UNHS) programs that uses benefit-cost ratio (BCR) to demonstrate an alternative method to audiologists, administrators, and others involved in UNHS protocol decisions. Existing data from more than 1200 ears were used to analyze BCR as a function of Distortion Product Otoacoustic Emission (DPOAE) level. These data were selected because both audiometric and DPOAE data were available on every ear. Although these data were not obtained in newborns, this compromise was necessary because audiometric outcomes (especially in infants with congenital hearing loss) in neonates are either lacking or limited in number. As such, it is important to note that the characteristics of responses from the group of subjects that formed the bases of the present analyses are different from those for neonates. This limits the extent to which actual criterion levels can be selected but should not affect the general approach of using BCR as a framework for considering UNHS criteria. Estimates of the prevalence of congenital hearing loss identified through UNHS in 37 states and U.S. territories in 2004 were used to calculate BCR. A range of estimates for the lifetime monetary benefits and yearly costs for UNHS were used, based on data available in the literature. Still, exact benefits and costs are difficult to know. Both one-step (DPOAE alone) and two-step (DPOAE followed by automated auditory brainstem response, AABR) screening paradigms were considered in the calculation of BCR. The influence of middle ear effusion was simulated by incorporating a range of expected DPOAE level reductions into an additional BCR analyses Our calculations indicate that for a range of proposed benefit and cost estimates, the monetary benefits of both one-step (DPOAE alone) and two-step (DPOAE followed by AABR) NHS programs outweigh programmatic costs. Our calculations indicate that BCR is robust in that it can be applied regardless of the values that are assigned to benefit and cost. Maximum BCR was identified and remained stable regardless of these values; however, it was recognized that the use of maximum BCR could result in reduced test sensitivity and may not be optimal for use in UNHS programs. The inclusion of secondary AABR screening increases BCR but does not alter the DPOAE criterion level at which maximum BCR occurs. The model of middle ear effusion reduces overall DPOAE level, subsequently lowering the DPOAE criterion level at which maximum BCR was obtained BCR is one of several alternative methods for choosing UNHS criteria, in which the evaluation of costs and benefits allows clinical and societal considerations to be incorporated into the pass/refer decision in a meaningful way. Although some of the benefits of early identification of hearing impairment cannot be estimated through a monetary analysis, such as improved psychosocial development and quality of life, this article provides an alternative to audiologists and administrators for selecting UNHS protocols that includes consideration of societal implications of UNHS screening criteria. BCR suggests that UNHS is a worthwhile investment for society as benefits always outweigh costs, at least for the estimations included in this article. Although the use of screening criteria that maximize BCR results in lower test sensitivity compared with other criteria, BCR may be used to select criteria that result in increased test sensitivity and still provide a high, although not maximal, BCR. Using BCR analysis provides a framework in which the societal implications of NHS protocols are considered and emphasizes the value of UNHS.
Mosites, Emily; Neitzel, Richard; Galusha, Deron; Trufan, Sally; Dixon-Ernst, Christine; Rabinowitz, Peter
2016-12-01
We assessed the reliability of a hearing risk factor screening survey used by hearing conservation programmes for noise-exposed workers. We compared workers' answers from the screening survey to their answers to a confidential research questionnaire regarding hearing loss risk factors. We calculated kappa statistics to test the correlation between yes/no questions in the research questionnaire compared to answers from 1 and 5 years of screening surveys. We compared the screening survey and research questionnaire answers of 274 aluminum plant workers. Most of the questions in the in-company screening survey showed fair to moderate agreement with the research questionnaire (kappa range: -0.02, 0.57). Workers' answers to the screening survey had better correlation with the research questionnaire when we compared 5 years of screening answers. For nearly all questions, workers were more likely to respond affirmatively on the research questionnaire than the screening survey. Hearing conservation programmes should be aware that workers may underreport hearing loss risk factors and functional hearing status on an audiometric screening survey. Validating company screening tools could help provide more accurate information on hearing loss and risk factors.
Smartphone-Based Hearing Screening in Noisy Environments
Na, Youngmin; Joo, Hyo Sung; Yang, Hyejin; Kang, Soojin; Hong, Sung Hwa; Woo, Jihwan
2014-01-01
It is important and recommended to detect hearing loss as soon as possible. If it is found early, proper treatment may help improve hearing and reduce the negative consequences of hearing loss. In this study, we developed smartphone-based hearing screening methods that can ubiquitously test hearing. However, environmental noise generally results in the loss of ear sensitivity, which causes a hearing threshold shift (HTS). To overcome this limitation in the hearing screening location, we developed a correction algorithm to reduce the HTS effect. A built-in microphone and headphone were calibrated to provide the standard units of measure. The HTSs in the presence of either white or babble noise were systematically investigated to determine the mean HTS as a function of noise level. When the hearing screening application runs, the smartphone automatically measures the environmental noise and provides the HTS value to correct the hearing threshold. A comparison to pure tone audiometry shows that this hearing screening method in the presence of noise could closely estimate the hearing threshold. We expect that the proposed ubiquitous hearing test method could be used as a simple hearing screening tool and could alert the user if they suffer from hearing loss. PMID:24926692
Lok, Willeke; Anteunis, Lucien J. C.; Chenault, Michelene N.; Meesters, Cor; Haggard, Mark P.
2012-01-01
Objective The present study investigates whether general practitioner (GP) consultation initiated by failing the population hearing screening at age nine months or GP consultation because of parental concern over ear/hearing problems was more important in deciding on referral and/or surgical treatment of otitis media (OM). Design A questionnaire covering the history between birth and 21 months of age was used to obtain information on referral after failing the hearing screening, GP consultations for ear/hearing problems, and subsequent referral to a specialist and possible surgical treatment at an ENT department. Setting The province of Limburg, the Netherlands. Subjects Healthy infants invited for the hearing screening at age nine months, who responded in an earlier study called PEPPER (Persistent Ear Problems, Providing Evidence for Referral, response rate 58%). Main outcome measures The odds of a child being surgically treated for OM. Results The response rate for the present questionnaire was 72%. Of all children tested, 3.9% failed the hearing screening and were referred to their GP. Of all 2619 children in this study, 18.6% visited their GP with ear/hearing problems. Children failing the hearing screening without GP consultation for ear/hearing problems were significantly more often treated surgically for OM than children passing the hearing screening but with GP consultation for ear/hearing problems. Conclusion Objectified hearing loss, i.e. failing the hearing screening, was important in the decision for surgical treatment in infants in the Netherlands. PMID:22794165
Interventions following hearing screening in adults: a systematic descriptive review.
Pronk, Marieke; Kramer, Sophia E; Davis, Adrian C; Stephens, Dafydd; Smith, Pauline A; Thodi, Chryssoula; Anteunis, Lucien J C; Parazzini, Marta; Grandori, Ferdinando
2011-09-01
Adult hearing screening may be a solution to the under-diagnosis and under-treatment of hearing loss in adults. Limited use and satisfaction with hearing aids indicate that consideration of alternative interventions following hearing screening may be needed. The primary aim of this study is to provide an overview of all intervention types that have been offered to adult (≥ 18 years) screen-failures. Systematic literature review. Articles were identified through systematic searches in PubMed, EMBASE, Cinahl, the Cochrane Library, private libraries, and through reference checking. Of the initial 3027 papers obtained from the searches, a total of 37 were found to be eligible. The great majority of the screening programmes (i.e. 26) referred screen-failures to a hearing specialist without further rehabilitation being specified. Most of the others (i.e. seven) led to the provision of hearing aids. Four studies offered alternative interventions comprising communication programme elements (e.g. speechreading, hearing tactics) or advice on environmental aids. Interventions following hearing screening generally comprised referral to a hearing specialist or hearing aid rehabilitation. Some programmes offered alternative rehabilitation options. These may be valuable as an addition to or replacement of hearing aid rehabilitation. It is recommended that this be addressed in future research.
Mosites, Emily; Neitzel, Richard; Galusha, Deron; Trufan, Sally; Dixon-Ernst, Christine; Rabinowitz, Peter
2017-01-01
Objective We assessed the reliability of a hearing risk factor screening survey used by hearing conservation programs for noise-exposed workers. Design We compared workers’ answers from the screening survey to their answers to a confidential research questionnaire regarding hearing loss risk factors. We calculated kappa statistics to test the correlation between yes/no questions in the research questionnaire compared to answers from one and five years of screening surveys. Study Sample We compared the screening survey and research questionnaire answers of 274 aluminum plant workers. Results Most of the questions in the in-company screening survey showed fair to moderate agreement with the research questionnaire (kappa range: −0.02, 0.57). Workers’ answers to the screening survey had better correlation with the research questionnaire when we compared five years of screening answers. For nearly all questions, workers were more likely to respond affirmatively on the research questionnaire than the screening survey. Conclusions Hearing conservation programs should be aware that workers may underreport hearing loss risk factors and functional hearing status on an audiometric screening survey. Validating company screening tools could help provide more accurate information on hearing loss and risk factors. PMID:27609310
Sign Language and Spoken Language for Children With Hearing Loss: A Systematic Review.
Fitzpatrick, Elizabeth M; Hamel, Candyce; Stevens, Adrienne; Pratt, Misty; Moher, David; Doucet, Suzanne P; Neuss, Deirdre; Bernstein, Anita; Na, Eunjung
2016-01-01
Permanent hearing loss affects 1 to 3 per 1000 children and interferes with typical communication development. Early detection through newborn hearing screening and hearing technology provide most children with the option of spoken language acquisition. However, no consensus exists on optimal interventions for spoken language development. To conduct a systematic review of the effectiveness of early sign and oral language intervention compared with oral language intervention only for children with permanent hearing loss. An a priori protocol was developed. Electronic databases (eg, Medline, Embase, CINAHL) from 1995 to June 2013 and gray literature sources were searched. Studies in English and French were included. Two reviewers screened potentially relevant articles. Outcomes of interest were measures of auditory, vocabulary, language, and speech production skills. All data collection and risk of bias assessments were completed and then verified by a second person. Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) was used to judge the strength of evidence. Eleven cohort studies met inclusion criteria, of which 8 included only children with severe to profound hearing loss with cochlear implants. Language development was the most frequently reported outcome. Other reported outcomes included speech and speech perception. Several measures and metrics were reported across studies, and descriptions of interventions were sometimes unclear. Very limited, and hence insufficient, high-quality evidence exists to determine whether sign language in combination with oral language is more effective than oral language therapy alone. More research is needed to supplement the evidence base. Copyright © 2016 by the American Academy of Pediatrics.
Hu, Xiangyang; Gong, Rui; Wen, Xu
2018-01-01
Hearing loss is the most common sensory impairment, but limited studies focused on the association of socioeconomic status (SES) with hearing loss among adults of working age. This paper aimed to fill this gap among Chinese adults. We obtained data from Ear and Hearing Disorder Survey conducted in four provinces of China in 2014–2015. The survey was based on WHO Ear and Hearing Disorders Survey Protocol and 25,860 adults aged 25 to 59 years were selected in this study. Trained local examiners performed pure tone audiometry to screen people with hearing loss, and those who were screened positively for hearing loss were referred to audiologists to make final diagnosis. SES was measured by occupation, education and income. Results show after adjusting for SES measures and covariates, in urban areas, compared with white-collar workers, blue-collar workers and the unemployed were more likely to have hearing loss, with an odds ratio of 1.2 (95%CI: 1.0, 1.3) and 1.2 (95%CI: 1.0, 1.4), respectively. Compared with people with education of senior high school or above, those with junior high school, primary school and illiteracy had 1.6 (95%CI: 1.4, 1.8), 2.1(95%CI: 1.7, 2.5) and 2.6 (95%CI: 1.9, 3.7) times as likely to have hearing loss, respectively. In rural areas, the unemployed had 1.5 (95%CI: 1.0, 2.3) times the risk of hearing loss compared with white-collar workers, and illiterates had 1.6 (95%CI: 1.6, 2.1) times the risk of hearing loss compared with people with education of senior high school or above, after SES variables and covariates were taken into considerations. Income was not significantly associated with hearing loss in urban and rural areas. In conclusion, SES, in the form of occupation and education, was associated with hearing loss among working-aged population, and further studies are needed to explore the mechanism of such association. PMID:29596478
[Compliance with current standards for the early detection of neonatal hearing loss].
Rojas-Godoy, Andrea L; Gómez-Gómez, Olga; Rivas-Muñoz, Fabio A
2014-01-01
Assessing compliance with the section "Assessment of hearing" stipulated in the Technical Standard to Detect Alteration in children aged less than 10 years-old in Bogota. This was a cross-sectional study which involved reviewing the medical records of all children born between July 1st and December 31st 2010 in two healthcare institutions in Bogota. Records were selected in which any of the following risk factors appeared: neonatal hyperbilirubinaemia involving phototherapy, neonatal exposure to ototoxic substances and/or <1.500 gr low birth weight. It was also ascertained whether children had been referred to an auditory evoked potential test as the prescribed screening test for neonatal hearing, as stipulated in mandatory Colombian technical standards for detecting abnormal growth and developmental in children aged less than ten years-old. Neither of the two institutions was making the aforementioned referral test. The results indicated significant difficulties in adherence to the protocol for the early detection of hearing loss regarding pertinent/current neonatal Colombian regulations.
Medoro, Alexandra; Malhotra, Prashant; Shimamura, Masako; Hounam, Gina; Findlen, Ursula; Wozniak, Phillip; Foor, Nicholas; Adunka, Oliver; Sanchez, Pablo J
2017-01-01
Abstract Background Congenital CMV infection is the leading cause of non-genetic sensorineural hearing loss in infancy. Antiviral therapy has been shown to improve hearing outcomes, and thus “targeted” CMV screening for newborns who do not pass the hearing screen has been recommended. Diagnosis of congenital CMV infection requires that the infant be tested for CMV in the first 3 weeks of age. Our objective was to determine when infants in the neonatal intensive care unit (NICU) have their first hearing screen performed and thus inform the practice of targeted screening for determination of CMV-related hearing loss. Methods Retrospective review of the electronic health records of all infants admitted to the Level 4 outborn NICU at Nationwide Children’s Hospital, Columbus, OH from August 2016 to May 2017. Demographic and clinical data were obtained, and the age that the first hearing screen was performed was assessed. Results During the 10 month study period, 362 infants were admitted to the NICU and had a first hearing screen performed. The majority of neonates (204, 56%) had a first hearing screen performed in the first 3 weeks of age. However, 158 (44%; median birth weight [IQR], 1072 g [747–1766]; median gestational age [IQR], 28 weeks [25–32]) infants received the first hearing screen at >3 weeks of age when a positive CMV PCR or culture cannot distinguish congenital infection from intrapartum/postnatal acquisition of CMV. Of the 158 infants, 20 (13%) did not pass the first hearing screen (13, unilateral; 7, bilateral), and subsequently, 9 of them did pass a second hearing screen. However, 11 of the 20 infants did not pass a second hearing screen and had urine CMV PCR testing, and 1 (9%) was positive. This latter infant’s newborn dried blood spot CMV DNA PCR was negative so a diagnosis of congenital CMV infection was not possible. Conclusion Targeted screening in the NICU for CMV-related hearing loss is problematic as a substantial number of infants do not have a hearing screen performed until after 21 days of age, thus representing a missed opportunity for diagnosis of congenital CMV infection and institution of antiviral therapy if indicated. Our findings support universal CMV screening of neonates on admission to the NICU. Disclosures O. Adunka, MED-EL Corporation: Consultant, Consulting fee, Educational grant and Research support; Advanced Bionics: Consultant, Consulting fee and Licensing agreement or royalty; Advanced Cochlear Diagnostics: President, Ownership interest; AGTC Corporation: Consultant, Consulting fee
Targeted surveillance for postnatal hearing loss: a program evaluation.
Beswick, Rachael; Driscoll, Carlie; Kei, Joseph; Glennon, Shirley
2012-07-01
The importance of monitoring hearing throughout early childhood cannot be understated. However, there is a lack of evidence available regarding the most effective method of monitoring hearing following the newborn screen. The goal of this study was to describe a targeted surveillance program using a risk factor registry to identify children with a postnatal hearing loss. All children who were born in Queensland, Australia between September 2004 and December 2009, received a bilateral 'pass' on newborn hearing screening, and had at least one risk factor, were referred for targeted surveillance and were included in this study. The cohort was assessed throughout early childhood in accordance with Queensland's diagnostic assessment protocols. During the study period, 7320 (2.8% of 261,328) children were referred for targeted surveillance, of which 56 were identified with a postnatal hearing loss (0.77%). Of these, half (50.0%) were identified with a mild hearing loss, and 64.3% were identified with a sensorineural hearing loss. In regards to risk factors, syndrome, craniofacial anomalies, and severe asphyxia had the highest yield of positive cases of postnatal hearing loss for children referred for targeted surveillance, whereas, low birth weight, bacterial meningitis, and professional concern had a particularly low yield. Limitations of the targeted surveillance program were noted and include: (1) a lost contact rate of 32.4%; (2) delays in first surveillance assessment; (3) a large number of children who required on-going monitoring; and (4) extensive diagnostic assessments were completed on children with normal hearing. Examination of the lost contact rate revealed indigenous children were more likely to be documented as lost contact. In addition, children with one risk factor only were significantly more likely to not attend a surveillance appointment. Positive cases of postnatal hearing loss were detected through the targeted surveillance program. However, the limitations of the program question the usefulness of this service delivery model. For targeted surveillance to continue, time frames for assessment, assessments performed, and discharge criteria need to be revisited. The contribution of individual and combined risk factors in detecting postnatal hearing loss should also be examined in more detail. Crown Copyright © 2012. Published by Elsevier Ireland Ltd. All rights reserved.
An analysis of hearing screening test results in 2291 premature infants of Chinese population.
Huang, Lili; Xiong, Fei; Li, Jinrong; Yang, Fan
2017-04-01
The aim of this study was to analyze the hearing screening program among preterm infants as well as to identify risk factors associated with failing primary newborn hearing screening. The retrospectively selected population included all preterm infants who had primary hearing screening in a neonatal ward from January 1st, 2013 to December 31st, 2015 at West China Second University Hospital, Sichuan University. The newborn hearing screening (NHS) procedure was performed in all preterm infants by automated auditory brainstem response (AABR). Infants who failed the primary hearing screening received a second screening at 42 days after birth. Infants who failed both tests were referred to a tertiary audiology center for diagnostic confirmation and management before 6 months of age. The final diagnosis for referred infants was obtained by telephone follow-up. The risk factors associated with failure to pass the primary hearing screen were evaluated and analyzed for preterm infants. Among 2291 preterm infants recruited, 155 infants (6.8%) failed the primary hearing screening with an abnormal AABR. Of these 155 infants, 113 (72.9%) passed the secondary screening. At the end of the follow-up, 1 infant (0.04%) was diagnosed with hearing loss, 3 infants had delayed language development, and 40 infants were lost to follow up. Multivariate regression analysis revealed that gestational age ≤32 weeks (Odds ratio [OR] = 2.093, 95% confidence interval [CI] 1.370-3.196), super hyperbilirubinemia (≥25 mg/dl) (OR = 3.560, 95% CI 1.009-12.560), and respiratory failure (OR = 1.971, 95% CI 1.188-3.265) were associated with failure to pass newborn hearing screening. The prevalence of failure to pass primary hearing screening among preterm infants was 6.8% in our study, and we found a relatively low prevalence of hearing loss (0.04%). Super hyperbilirubinemia, gestational age ≤32weeks, and respiratory failure were risk factors associated with failure of preterm infants to pass the primary hearing screening. Our results suggest that preterm infants with hyperbilirubinemia, gestational age ≤32 weeks, and respiratory failure should be closely followed. Copyright © 2017 Elsevier B.V. All rights reserved.
Garrette, Rachel; Jones, Alisha L; Wilson, Martha W
2018-05-15
The purpose of this study is to investigate whether acoustic reflex threshold testing before administration of distortion product otoacoustic emissions can affect the results of the distortion product otoacoustic emissions testing using an automated protocol. Fifteen young adults with normal hearing ranging in age from 19 to 25 years participated in the study. All participants had clear external ear canals and normal Jerger Type A tympanograms and had passed a hearing screening. Testing was performed using the Interacoustics Titan acoustic reflex threshold and distortion product otoacoustic emissions protocol. Participants underwent baseline distortion product otoacoustic emissions. A paired-samples t test was conducted for both the right and left ears to assess within-group differences between baseline distortion product otoacoustic emissions and repeated distortion product otoacoustic emissions measures. No significant differences were found in distortion product otoacoustic emission measures following administration of acoustic reflexes. The use of a protocol when using an automated system that includes both acoustic reflexes and distortion product otoacoustic emissions is important. Overall, presentation of acoustic reflexes prior to measuring distortion product otoacoustic emission did not affect distortion product otoacoustic emission results; therefore, test sequence can be modified as needed.
Garinis, Angela C; Liao, Selena; Cross, Campbell P; Galati, Johnathan; Middaugh, Jessica L; Mace, Jess C; Wood, Anna-Marie; McEvoy, Lindsey; Moneta, Lauren; Lubianski, Troy; Coopersmith, Noe; Vigo, Nicholas; Hart, Christopher; Riddle, Artur; Ettinger, Olivia; Nold, Casey; Durham, Heather; MacArthur, Carol; McEvoy, Cynthia; Steyger, Peter S
2017-06-01
Hearing loss rates in infants admitted to neonatal intensive care units (NICU) run at 2-15%, compared to 0.3% in full-term births. The etiology of this difference remains poorly understood. We examined whether the level of ambient sound and/or cumulative gentamicin (an aminoglycoside) exposure affect NICU hearing screening results, as either exposure can cause acquired, permanent hearing loss. We hypothesized that higher levels of ambient sound in the NICU, and/or gentamicin dosing, increase the risk of referral on the distortion product otoacoustic emission (DPOAE) assessments and/or automated auditory brainstem response (AABR) screens. This was a prospective pilot outcomes study of 82 infants (<37 weeks gestational age) admitted to the NICU at Oregon Health & Science University. An ER-200D sound pressure level dosimeter was used to collect daily sound exposure in the NICU for each neonate. Gentamicin dosing was also calculated for each infant, including the total daily dose based on body mass (mg/kg/day), as well as the total number of treatment days. DPOAE and AABR assessments were conducted prior to discharge to evaluate hearing status. Exclusion criteria included congenital infections associated with hearing loss, and congenital craniofacial or otologic abnormalities. The mean level of ambient sound was 62.9 dBA (range 51.8-70.6 dBA), greatly exceeding American Academy of Pediatrics (AAP) recommendation of <45.0 dBA. More than 80% of subjects received gentamicin treatment. The referral rate for (i) AABRs, (frequency range: ∼1000-4000 Hz), was 5%; (ii) DPOAEs with a broad F2 frequency range (2063-10031 Hz) was 39%; (iii) DPOAEs with a low-frequency F2 range (<4172 Hz) was 29%, and (iv) DPOAEs with a high-frequency F2 range (>4172 Hz) was 44%. DPOAE referrals were significantly greater for infants receiving >2 days of gentamicin dosing compared to fewer doses (p = 0.004). The effect of sound exposure and gentamicin treatment on hearing could not be determined due to the low number of NICU infants without gentamicin exposure (for control comparisons). All infants were exposed to higher levels of ambient sound that substantially exceed AAP guidelines. More referrals were generated by DPOAE assessments than with AABR screens, with significantly more DPOAE referrals with a high-frequency F2 range, consistent with sound- and/or gentamicin-induced cochlear dysfunction. Adding higher frequency DPOAE assessments to existing NICU hearing screening protocols could better identify infants at-risk for ototoxicity. Copyright © 2017 Elsevier B.V. All rights reserved.
Garinis, Angela C.; Liao, Selena; Cross, Campbell P.; Galati, Johnathan; Middaugh, Jessica L.; Mace, Jess C.; Wood, Anna-Marie; McEvoy, Lindsey; Moneta, Lauren; Lubianski, Troy; Coopersmith, Noe; Vigo, Nicholas; Hart, Christopher; Riddle, Artur; Ettinger, Olivia; Nold, Casey; Durham, Heather; MacArthur, Carol; McEvoy, Cynthia; Steyger, Peter S.
2017-01-01
Objective Hearing loss rates in infants admitted to neonatal intensive care units (NICU) run at 2–15%, compared to 0.3% in full-term births. The etiology of this difference remains poorly understood. We examined whether the level of ambient sound and/or cumulative gentamicin (an aminoglycoside) exposure affect NICU hearing screening results, as either exposure can cause acquired, permanent hearing loss. We hypothesized that higher levels of ambient sound in the NICU, and/or gentamicin dosing, increase the risk of referral on the distortion product otoacoustic emission (DPOAE) assessments and/or automated auditory brainstem response (AABR) screens. Methods This was a prospective pilot outcomes study of 82 infants (<37 weeks gestational age) admitted to the NICU at Oregon Health & Science University. An ER-200D sound pressure level dosimeter was used to collect daily sound exposure in the NICU for each neonate. Gentamicin dosing was also calculated for each infant, including the total daily dose based on body mass (mg/kg/day), as well as the total number of treatment days. DPOAE and AABR assessments were conducted prior to discharge to evaluate hearing status. Exclusion criteria included congenital infections associated with hearing loss, and congenital craniofacial or otologic abnormalities. Results The mean level of ambient sound was 62.9 dBA (range 51.8–70.6 dBA), greatly exceeding American Academy of Pediatrics (AAP) recommendation of <45.0 dBA. More than 80% of subjects received gentamicin treatment. The referral rate for (i) AABRs, (frequency range: ~1000–4000 Hz), was 5%; (ii) DPOAEs with a broad F2 frequency range (2063–10031 Hz) was 39%; (iii) DPOAEs with a low-frequency F2 range (<4172 Hz) was 29%, and (iv) DPOAEs with a high-frequency F2 range (>4172 Hz) was 44%. DPOAE referrals were significantly greater for infants receiving >2 days of gentamicin dosing compared to fewer doses (p= 0.004). The effect of sound exposure and gentamicin treatment on hearing could not be determined due to the low number of NICU infants without gentamicin exposure (for control comparisons). Conclusion All infants were exposed to higher levels of ambient sound that substantially exceed AAP guidelines. More referrals were generated by DPOAE assessments than with AABR screens, with significantly more DPOAE referrals with a high-frequency F2 range, consistent with sound- and/or gentamicin-induced cochlear dysfunction. Adding higher frequency DPOAE assessments to existing NICU hearing screening protocols could better identify at-risk infants to be referred for diagnostic evaluation. PMID:28483249
Hearing Screening Follow-Up: Completing the Process to Identify Hearing Health Needs
ERIC Educational Resources Information Center
Eiserman, William; Shisler, Lenore; Hoffman, Jeff
2015-01-01
Hearing is at the heart of language development and school readiness; increasing numbers of Early Head Start programs have come to rely on otoacoustic emissions (OAE) technology to screen all infants and toddlers for hearing loss. Successful identification of hearing health needs is dependent not only on an appropriate screening method, but also…
Identifying congenital hearing impairment. Personal experience based on selective hearing screening.
Molini, E; Ricci, G; Baroni, S; Ciorba, A; Bellocci, A; Simoncelli, C
2004-06-01
If all degrees of permanent uni- or bilateral hypoacusis are taken into consideration, hearing impairment is the most common congenital disease. Early detection of permanent infantile hearing impairment has become extremely important in preventive medicine, since steps can be taken with hearing aids and rehabilitation to ensure better development of language and higher cognitive functions. Aim of this study is to provide a critical review of the time of diagnosis of hypoacusis at our audiology laboratory, where two methods were used to screen hearing of children with/without risk indicators. Results of approximately 10 years' work were re-examined during which time outpatient screening was conducted on children referred by colleagues in neonatology and paediatrics. All were carriers of congenital risk indicators associated with sensorineural and/or conductive hearing loss, based on the Joint Committee on Infant Hearing findings, or were suspected of being hypoacusic even if they had no known congenital risk factors. Hearing screening was conducted in hospital on newborns with no risk factors, within the first few days of birth. Results of the present study showed that when selective hearing screening was performed, the mean age of high-risk patients diagnosed with hypoacusis was slightly higher than that in international guidelines. Moreover, these patients represent approximately half the hypoacusic population identified in the study period. The other half of congenital hypoacusic subjects identified had no risk indicators and there was a significant delay in diagnosis due to later manifestation of symptoms indicating hypoacusis, and thus, in turn, delayed referral for hearing tests. In contrast, subjects without risk indicators who underwent in-hospital hearing screening and proved to be hypoacusic, were diagnosed early. In our experience, however, universal screening has considerable disadvantages, such as difficulty in covering the entire population, difficulty in follow-up after discharge from hospital, and last, but by no means least, significant organisational and professional commitments, making it impossible to perform in all hospitals. In order to ensure effective hearing screening for congenital hearing loss and, thus permit prompt identification of hypoacusic children, use of hearing aids and rehabilitation screening should incorporate two aspects. First, selection should be compulsory, thereby reducing waiting time between collecting case histories and performing outpatient tests; second, hospital screening of children without risk factors should be performed whenever possible. Integrating these two aspects would make it possible to approach the "utopia" of universal hearing screening.
Hearing screening in children with skeletal dysplasia.
Tunkel, David E; Kerbavaz, Richard; Smith, Beth; Rose-Hardison, Danielle; Alade, Yewande; Hoover-Fong, Julie
2011-12-01
To determine the prevalence of hearing loss and abnormal tympanometry in children with skeletal dysplasia. Clinical screening program. National convention of the Little People of America. Convenience sample of volunteers aged 18 years or younger with skeletal dysplasias. Hearing screening with behavioral testing and/or otoacoustic emissions, otoscopy, and tympanometry. A failed hearing screen was defined as hearing 35 dB HL (hearing level) or greater at 1 or more tested frequencies or by a "fail" otoacoustic emissions response. Types B and C tympanograms were considered abnormal. A total of 58 children (aged ≤18 years) with skeletal dysplasia enrolled, and 56 completed hearing screening. Forty-one children had normal hearing (71%); 9 failed in 1 ear (16%); and 6 failed in both ears (10%). Forty-four children had achondroplasia, and 31 had normal hearing in both ears (71%); 8 failed hearing screening in 1 ear (18%), and 3 in both ears (7%). Tympanometry was performed in 45 children, with normal tympanograms found in 21 (47%), bilateral abnormal tympanograms in 15 (33%), and unilateral abnormal tympanograms in 9 (20%). Fourteen children with achondroplasia had normal tympanograms (42%); 11 had bilateral abnormal tympanograms (33%); and 8 had unilateral abnormal tympanograms (24%). For those children without functioning tympanostomy tubes, there was a 9.5 times greater odds of hearing loss if there was abnormal tympanometry (P = .03). Hearing loss and middle-ear disease are both highly prevalent in children with skeletal dysplasias. Abnormal tympanometry is highly associated with the presence of hearing loss, as expected in children with eustachian tube dysfunction. Hearing screening with medical intervention is recommended for these children.
Results of a neonatal hearing screening program in Maceió.
Dantas, Margareth Barbosa de Souza; Anjos, César Antônio Lira Dos; Camboim, Elizângela Dias; Pimentel, Marcella de Carvalho Ramos
2009-01-01
Since 1998, after we started the support group for neonatal hearing screening, many other hearing screening programs were held in Brazil. In Alagoas, the first program started in 2003, but none of its results were published. Hearing is paramount for human communication; therefore, childhood hearing loss can impair speech acquisition, emotional, educational and social development. to present the results achieved in a neonatal hearing screening program in Maceió. a retrospective analytical study was carried out in order to study the results from tests carried out from September 2003 to December 2006 in a private hospital of Maceió. from a total of 2002 newborns, 1,626 fitted the inclusion criteria, 835 (51.4%) males. The hearing screening was considered appropriate in 1416 cases (87.1%), and the most frequently found age was between 16 and 30 days. Finally, 163 (10.0%) children presented risk indicators for hearing loss, and hyperbilirubinemia was the most common indicator. statistical results obtained from this hearing screening program show the importance of holding such programs. This study is important because it contributes to further regional or multinational studies.
Driscoll, C; Kei, J; McPherson, B
2001-01-01
(1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at > or =1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery.
The Sensitivity of Adolescent Hearing Screens Significantly Improves by Adding High Frequencies.
Sekhar, Deepa L; Zalewski, Thomas R; Beiler, Jessica S; Czarnecki, Beth; Barr, Ashley L; King, Tonya S; Paul, Ian M
2016-09-01
One in 6 US adolescents has high-frequency hearing loss, often related to hazardous noise. Yet, the American Academy of Pediatrics (AAP) hearing screen (500, 1,000, 2,000, 4,000 Hertz) primarily includes low frequencies (<3,000 Hertz). Study objectives were to determine (1) sensitivity and specificity of the AAP hearing screen for adolescent hearing loss and (2) if adding high frequencies increases sensitivity, while repeat screening of initial referrals reduces false positive results (maintaining acceptable specificity). Eleventh graders (n = 134) participated in hearing screening (2013-2014) including "gold-standard" sound-treated booth testing to calculate sensitivity and specificity. Of the 43 referrals, 27 (63%) had high-frequency hearing loss. AAP screen sensitivity and specificity were 58.1% (95% confidence interval 42.1%-73.0%) and 91.2% (95% confidence interval 83.4-96.1), respectively. Adding high frequencies (6,000, 8,000 Hertz) significantly increased sensitivity to 79.1% (64.0%-90.0%; p = .003). Specificity with repeat screening was 81.3% (71.8%-88.7%; p = .003). Adolescent hearing screen sensitivity improves with high frequencies. Repeat testing maintains acceptable specificity. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Calcutt, Trent L; Dornan, Dimity; Beswick, Rachael; Tudehope, David I
2016-08-13
This study compares rates and timing of newborn hearing screening outcomes, audiological assessment and hearing loss diagnosis between infants of different gestational age groups. Early identification and management of sensorineural hearing loss (SNHL), ideally by 3-6 months of age, facilitates speech and language optimisation. Literature stratifying hearing screening and diagnostic audiology assessment by gestational age groups is lacking. Subjects were infants with recorded gestational ages receiving newborn hearing screening in Queensland between 2009 and 2011. Data were provided through the Queensland Healthy Hearing database. Infants were analysed in <34 weeks, 34-36 +6 weeks, 37-38 +6 weeks and ≥39 weeks gestational age groups. Infants (175 911) were eligible for analysis, 7.9% being preterm. Per 1000 infants analysed, bilateral SNHL of >40 dB occurred in 2.4 for <34, 1.4 for 34-36 +6 , 0.7 for 37-38 +6 and 0.7 for ≥39 weeks gestation. Diagnoses attributable to newborn hearing screening direct referral were 93.1% for bilateral >40 dB SNHL and 88.2% for other hearing loss. Relative to term, preterm infants had a higher incidence of direct and targeted surveillance referrals, audiology assessment and hearing loss diagnosis. Preterm infants were screened later after birth. Specific hearing screening and diagnosis characteristics differed between preterm infants <34 and 34-36 +6 weeks gestation, and term infants. Consideration of unique gestational age strata characteristics supports care individualisation. Preterm infants represent a diagnostic challenge, with higher rates of bilateral >40 dB SNHL than term but correspondingly higher false positive results on screening, justifying vigilant monitoring. Focused research into specific risk factors in preterm infants is warranted. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
[Hearing screening at nursery schools: results of an evaluation study].
Weichbold, Viktor; Rohrer, Monika; Winkler, Cornelia; Welzl-Müller, Kunigunde
2004-07-31
This study aimed to evaluate the hearing screening of pre-school children at nursery schools in Tyrol, Austria. 47 nursery schools with a total of 2199 enrolled children participated in the study. At the screening, the children were presented a series of tones at frequencies 0.5 kHz (25dB), 1 kHz, 2 kHz, 3 kHz, and 4 kHz (20 dB each) from portable audiometers. The tones were presented over headphones for each ear separately and at irregular intervals. Failure to respond to any of the frequencies was considered failure of the screening. Parents were then advised in written form to have the child examined by an ENT-specialist. 1832 individuals were screened (coverage: 83% of nursery school children; corresponding to at least 63% of all Tyrolean children aged 3 to 5 years). Of these, 390 failed the test (referral rate: 21% of all screened). Examination through an ENT-specialist occurred with 217 children, and this confirmed the positive test in 139 children (hit rate: 64%). In most cases, a temporary conductive hearing loss due to external or middle ear problems (glue ear, tube dysfunction, cerumen, otitis media) was diagnosed. A sensorineural hearing loss was found in 4 children (in 3 of them bilateral). The need for therapy was recognized in 81 children (4% of all screened). Pre-school hearing screening identifies children with ear and hearing problems that need therapeutical intervention. Although the hearing problems are mostly of a temporary nature, some may require monitoring over some period. Also some children with permanent sensorineural hearing loss may be detected through this measure. Hearing screening is an efficient means of assessing ear and hearing problems in pre-school children. However, the follow-up rate needs to be improved for optimizing the efficacy.
de Oliveira, Juliana Santos; Rodrigues, Liliane Barbosa; Aurélio, Fernanda Soares; da Silva, Virgínia Braz
2013-01-01
OBJECTIVE: To determine the prevalence of hearing loss and to analyze the results of newborn hearing screening and audiological diagnosis in private health care systems. METHODS Cross-sectional and retrospective study in a database of newborn hearing screening performed by a private clinic in neonates born in private hospitals of Porto Velho, Rondônia, Northern Brazil. The screening results, the risk for hearing loss, the risk indicators for hearing loss and the diagnosis were descriptively analyzed. Newborns cared in rooming in with their mothers were compared to those admitted to the Intensive Care Unit regarding risk factors for hearing loss. RESULTS: Among 1,146 (100%) enrolled newborns, 1,064 (92.8%) passed and 82 (7.2%) failed the hearing screening. Among all screened neonates, 1,063 (92.8%) were cared in rooming and 83 (7.2%) needed intensive care; 986 (86.0%) were considered at low risk and 160 (14.0%) at high risk for hearing problems. Of the 160 patients identified as having high risk for hearing loss, 83 (37.7%) were admitted to an hospitalized in the Intensive Care Unit, 76 (34.5%) used ototoxic drugs and 38 (17.2%) had a family history of hearing loss in childhood. Hearing loss was diagnosed in two patients (0.2% of the screened sample). CONCLUSIONS: The prevalence of hearing loss in newborns from private hospitals was two cases per 1,000 evaluated patients. The use of ototoxic drugs, admission to Intensive Care Unit and family history of hearing loss were the most common risk factors for hearing loss in the studied population. PMID:24142311
Silva, Daniela Polo Camargo da; Lopez, Priscila Suman; Ribeiro, Georgea Espíndola; Luna, Marcos Otávio de Mesquita; Lyra, João César; Montovani, Jair Cortez
2015-01-01
Early diagnosis of hearing loss minimizes its impact on child development. We studied factors that influence the effectiveness of screening programs. To investigate the relationship between gender, weight at birth, gestational age, risk factors for hearing loss, venue for newborn hearing screening and "pass" and "fail" results in the retest. Prospective cohort study was carried out in a tertiary referral hospital. The screening was performed in 565 newborns through transient evoked otoacoustic emissions in three admission units before hospital discharge and retest in the outpatient clinic. Gender, weight at birth, gestational age, presence of risk indicators for hearing loss and venue for newborn hearing screening were considered. Full-term infants comprised 86% of the cases, preterm 14%, and risk factors for hearing loss were identified in 11%. Considering the 165 newborns retested, only the venue for screening, Intermediate Care Unit, was related to "fail" result in the retest. Gender, weight at birth, gestational age and presence of risk factors for hearing loss were not related to "pass" and/or "fail" results in the retest. The screening performed in intermediate care units increases the chance of continued "fail" result in the Transient Otoacoustic Evoked Emissions test. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Targeting regional pediatric congenital hearing loss using a spatial scan statistic.
Bush, Matthew L; Christian, Warren Jay; Bianchi, Kristin; Lester, Cathy; Schoenberg, Nancy
2015-01-01
Congenital hearing loss is a common problem, and timely identification and intervention are paramount for language development. Patients from rural regions may have many barriers to timely diagnosis and intervention. The purpose of this study was to examine the spatial and hospital-based distribution of failed infant hearing screening testing and pediatric congenital hearing loss throughout Kentucky. Data on live births and audiological reporting of infant hearing loss results in Kentucky from 2009 to 2011 were analyzed. The authors used spatial scan statistics to identify high-rate clusters of failed newborn screening tests and permanent congenital hearing loss (PCHL), based on the total number of live births per county. The authors conducted further analyses on PCHL and failed newborn hearing screening tests, based on birth hospital data and method of screening. The authors observed four statistically significant (p < 0.05) high-rate clusters with failed newborn hearing screenings in Kentucky, including two in the Appalachian region. Hospitals using two-stage otoacoustic emission testing demonstrated higher rates of failed screening (p = 0.009) than those using two-stage automated auditory brainstem response testing. A significant cluster of high rate of PCHL was observed in Western Kentucky. Five of the 54 birthing hospitals were found to have higher relative risk of PCHL, and two of those hospitals are located in a very rural region of Western Kentucky within the cluster. This spatial analysis in children in Kentucky has identified specific regions throughout the state with high rates of congenital hearing loss and failed newborn hearing screening tests. Further investigation regarding causative factors is warranted. This method of analysis can be useful in the setting of hearing health disparities to focus efforts on regions facing high incidence of congenital hearing loss.
ERIC Educational Resources Information Center
Sekhar, Deepa L.; Zalewski, Thomas R.; Beiler, Jessica S.; Czarnecki, Beth; Barr, Ashley L.; King, Tonya S.; Paul, Ian M.
2016-01-01
High frequency hearing loss (HFHL), often related to hazardous noise, affects one in six U.S. adolescents. Yet, only 20 states include school-based hearing screens for adolescents. Only six states test multiple high frequencies. Study objectives were to (1) compare the sensitivity of state school-based hearing screens for adolescents to gold…
Hearing Screening in a Tertiary Care Hospital in India
Shah, Neha; Patel, Kalpesh B.; Vishwakarma, Rajesh
2015-01-01
Introduction: To study the incidence of hearing loss among children and to determine and confirm the distribution of common risk factors in children with hearing loss presenting at a tertiary care hospital in India. Materials and Methods: Babies underwent hearing screening using Transient Evoked Otoacoustic Emission (TEOAE) and Automated Auditory Brainstem Response (AABR) from November 2009 to September 2011. It was a cross-sectional study carried out at our institute involving 500 babies (≤2 y). To identify the high risk babies, Joint Committee on Infant Hearing (2007) High risk registry was used. Results: In our study 110 (22%) babies belonged to high risk category and 11(2.2%) of total screened babies had significant hearing loss. Total number of babies who passed the initial screening with TEOAE was 284 (56.8%). On diagnostic AABR screening of TEOAE REFERRED babies, the babies with no risk factor showed normal AABR tracings whereas from among those with one or multiple risk factors (110 babies), 11(10%) showed different levels of hearing impairment. Hearing loss was highly associated with Neonatal Intensive Care Unit (NICU) admission i.e. 8/11(72.7%), followed by Low Birth Weight (LBW) and hypoxia (6/11 i.e. 54.5% each). Conclusion: Hearing loss is more common in those babies with risk factors (majority being NICU admission, LBW and hypoxia). OAE and ABR screening of infants at risk for significant hearing loss is a clinically efficient and cost effective approach for early detection of significant hearing loss. PMID:25954639
ERIC Educational Resources Information Center
Johnson-Curiskis, Nanette
2012-01-01
Hearing levels are threatened by modern life--headsets for music, rock concerts, traffic noises, etc. It is crucial we know our hearing levels so that we can draw attention to potential problems. This exercise requires that students receive a hearing screening for their benefit as well as for making the connection of hearing to listening.
Greczka, Grazyna; Dabrowski, Piotr; Szyfter-Harris, Joanna; Mazela, Jan
2017-01-01
Objectives The incidence of sensorineural hearing loss is between 1 and 3 per 1000 in healthy neonates and 2–4 per 100 in high-risk infants. The national universal neonatal hearing screening carried out in Poland since 2002 enables selection of infants with suspicion and/or risk factors of hearing loss. In this study, we assessed the incidence and risk factors of hearing impairment in infants ≤33 weeks’ gestational age (wga). Methods We analyzed the database of the Polish Universal Newborns Hearing Screening Program from 2010 to 2013. The study group involved 11438 infants born before 33 wga, the control group—1487730 infants. Screening was performed by means of transient evoked otoacoustic emissions. The risk factors of hearing loss were recorded. Infants who failed the screening test and/or had risk factors were referred for further audiological evaluation. Results Hearing deficit was diagnosed in 11% of infants ≤25 wga, 5% at 26–27 wga, 3.46% at 28 wga and 2–3% at 29–32 wga. In the control group the incidence of hearing deficit was 0.2% (2.87% with risk factors). The most important risk factors were craniofacial malformations, very low birth weight, low Apgar score and mechanical ventilation. Hearing screening was positive in 22.42% newborns ≤28 wga and 10% at 29–32 wga and in the control group. Conclusions Hearing impairment is a severe consequence of prematurity. Its prevalence is inversely related to the maturity of the baby. Premature infants have many concomitant risk factors which influence the occurrence of hearing deficit. PMID:28910311
Carr, Jason; Xu, Dongxin; Yoshinaga-Itano, Christine
2014-11-01
The Language ENvironment Analysis Language and Autism Screen (LLAS) is an automated vocal production analysis that has been shown to be a valid screener for autism in hearing children between the ages of 24 to 48 months of age. Although there is reportedly a higher incidence of autism among children who are deaf or hard of hearing, the diagnosis of autism is usually later than that in children with hearing. None of the traditional screening instruments have been used with children with hearing loss. Data about the utility of LLAS with children who are deaf or hard of hearing will be presented and discussed. Though more data will be needed, an LLAS at-risk flag in conjunction with the Social Quotient from the Child Development Inventory holds significant promise for a screen for children who are deaf or hard of hearing. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Norton, S J; Gorga, M P; Widen, J E; Folsom, R C; Sininger, Y; Cone-Wesson, B; Vohr, B R; Mascher, K; Fletcher, K
2000-10-01
The purpose of this study was to compare the performance of transient evoked otoacoustic emissions (TEOAEs), distortion product otoacoustic emissions (DPOAEs), and auditory brain stem responses (ABRs) as tools for identification of neonatal hearing impairment. A total of 4911 infants including 4478 graduates of neonatal intensive care units, 353 well babies with one or more risk factors for hearing loss (Joint Committee on Infant Hearing, 1994) and 80 well babies without risk factor who did not pass one or more neonatal test were targeted as the potential subject pool on which test performance would be assessed. During the neonatal period, they were evaluated using TEOAEs in response to an 80 dB pSPL click, DPOAE responses to two stimulus conditions (L1 = L2 = 75 dB SPL and L1 = 65 dB SPL L2 = 50 dB SPL), and ABR elicited by a 30 dB nHL click. In an effort to describe test performance, these "at-risk" infants were asked to return for behavioral audiologic assessments, using visual reinforcement audiometry (VRA) at 8 to 12 mo corrected age, regardless of neonatal test results. Sixty-four percent of these subjects returned and reliable VRA data were obtained on 95.6% of these returnees. This approach is in contrast to previous studies in which, by necessity, efforts were made to follow only those infants who "failed" the neonatal screening tests. The accuracy of the neonatal measures in predicting hearing status at 8 to 12 mo corrected age was determined. Only those infants who provided reliable, monaural VRA test results were included in the analysis. Separate analyses were performed without regard to intercurrent events (i.e., events between the neonatal and VRA tests that could cause their results to disagree), and then after accounting for the possible influence of intercurrent events such as otitis media and late-onset or progressive hearing loss. Low refer rates were achieved for the stopping criteria used in the present study, especially when a protocol similar to the one recommended in the National Institutes of Health (1993) Consensus Conference Report was followed. These analyses, however, do not completely describe test performance because they did not compare neonatal screening test results with a gold standard test of hearing. Test performance, as measured by the area under a relative operating characteristic curve, were similar for all three neonatal tests when neonatal test results were compared with VRA data obtained at 8 to 12 mo corrected age. However, ABRs were more successful at determining auditory status at 1 kHz, compared with the otoacoustic emission (OAE) tests. Performance was more similar across all three tests when they were used to identify hearing loss at 2 and 4 kHz. No test performed perfectly. Using either the two- or three-frequency pure-tone average (PTA), with a fixed false alarm rate of 20%, hit rates for the neonatal tests, in general, exceeded 80% when hearing impairment was defined as behavioral thresholds > or =30 dB HL. All three tests performed similarly when a two-frequency (2 and 4 kHz) PTA was used as the gold standard; OAE test performance decreased when a three-frequency PTA (adding 1 kHz) was used as the gold standard definition. For both PTA and all three neonatal screening measures, however, hit rate increased as the magnitude of hearing loss increased. Singly, all three neonatal hearing screening tests resulted in low refer rates, especially if referrals for follow-up were made only for the cases in which stopping criteria were not met in both ears. Following a protocol similar to that recommended in the National Institutes of Health (1993) Consensus Conference report resulted in refer rates that were less than 4%. TEOAEs at 80 dB pSPL, DPOAE at L1 = 65, L2 = 50 dB SPL and ABR at 30 dB nHL measured during the neonatal period, and as implemented in the current study, performed similarly at predicting behavioral hearing status at 8 to 12
Gan, Kok Beng; Azeez, Dhifaf; Umat, Cila; Ali, Mohd Alauddin Mohd; Wahab, Noor Alaudin Abdul; Mukari, Siti Zamratol Mai-Sarah
2012-10-01
Hearing screening is important for the early detection of hearing loss. The requirements of specialized equipment, skilled personnel, and quiet environments for valid screening results limit its application in schools and health clinics. This study aimed to develop an automated hearing screening kit (auto-kit) with the capability of realtime noise level monitoring to ensure that the screening is performed in an environment that conforms to the standard. The auto-kit consists of a laptop, a 24-bit resolution sound card, headphones, a microphone, and a graphical user interface, which is calibrated according to the American National Standards Institute S3.6-2004 standard. The auto-kit can present four test tones (500, 1000, 2000, and 4000 Hz) at 25 or 40 dB HL screening cut-off level. The clinical results at 40 dB HL screening cut-off level showed that the auto-kit has a sensitivity of 92.5% and a specificity of 75.0%. Because the 500 Hz test tone is not included in the standard hearing screening procedure, it can be excluded from the auto-kit test procedure. The exclusion of 500 Hz test tone improved the specificity of the auto-kit from 75.0% to 92.3%, which suggests that the auto-kit could be a valid hearing screening device. In conclusion, the auto-kit may be a valuable hearing screening tool, especially in countries where resources are limited.
Fitzpatrick, Elizabeth M; Stevens, Adrienne; Garritty, Chantelle; Moher, David
2013-12-06
Permanent childhood hearing loss affects 1 to 3 per 1000 children and frequently disrupts typical spoken language acquisition. Early identification of hearing loss through universal newborn hearing screening and the use of new hearing technologies including cochlear implants make spoken language an option for most children. However, there is no consensus on what constitutes optimal interventions for children when spoken language is the desired outcome. Intervention and educational approaches ranging from oral language only to oral language combined with various forms of sign language have evolved. Parents are therefore faced with important decisions in the first months of their child's life. This article presents the protocol for a systematic review of the effects of using sign language in combination with oral language intervention on spoken language acquisition. Studies addressing early intervention will be selected in which therapy involving oral language intervention and any form of sign language or sign support is used. Comparison groups will include children in early oral language intervention programs without sign support. The primary outcomes of interest to be examined include all measures of auditory, vocabulary, language, speech production, and speech intelligibility skills. We will include randomized controlled trials, controlled clinical trials, and other quasi-experimental designs that include comparator groups as well as prospective and retrospective cohort studies. Case-control, cross-sectional, case series, and case studies will be excluded. Several electronic databases will be searched (for example, MEDLINE, EMBASE, CINAHL, PsycINFO) as well as grey literature and key websites. We anticipate that a narrative synthesis of the evidence will be required. We will carry out meta-analysis for outcomes if clinical similarity, quantity and quality permit quantitative pooling of data. We will conduct subgroup analyses if possible according to severity/type of hearing disorder, age of identification, and type of hearing technology. This review will provide evidence on the effectiveness of using sign language in combination with oral language therapies for developing spoken language in children with hearing loss who are identified at a young age. The information from this review can provide guidance to parents and intervention specialists, inform policy decisions and provide directions for future research. CRD42013005426.
How should hearing screening tests be offered?
Koopman, Jan; Davey, Elizabeth; Thomas, Neil; Wittkop, Thomas; Verschuure, Hans
2008-05-01
This paper deals with the question of how the general public should be addressed when offering hearing screening. Postal-based questionnaires in the United Kingdom, Germany, and The Netherlands were sent to users of hearing devices, those that are in the process of obtaining one, or those that have indicated that they have special interest in hearing. Results of the survey indicated that respondents were enthusiastic about the idea of being able to carry out hearing self-screening tests via the internet, telephone, or questionnaires. A questionnaire as a method to screen on hearing was generally preferred above using the internet, which was preferred over using the telephone for the test. About 27% of the respondents indicated to use exclusively one method. Most respondents indicated that either method provided would be of interest (41%), 17% indicated not to be interested in conducting screening tests using the internet.
Polish universal neonatal hearing screening program-4-year experience (2003-2006).
Szyfter, Witold; Wróbel, Maciej; Radziszewska-Konopka, Marzanna; Szyfter-Harris, Joanna; Karlik, Michał
2008-12-01
The aim of this paper is to share our experience and observations in running the Universal Neonatal Hearing Screening Program on a national level, present results and indicate some problems that have arisen during these 4 years. Polish Universal Neonatal Hearing Screening Program started back in 2002 in all neonatal units in Poland. Implemented testing methods consisted of test of transient evoked otoacoustic emission (TEOAE) performed in all new born children in their first 2-3 days of life and auditory brainstem response testing (ABR) conducted on children, who did not meet the TEOAE pass criteria. Additional questionnaire registered information on ototoxic drugs and family history of hearing impairment in every newborn. Diagnosed children were further referred for treatment and rehabilitation. After 4 years of running the program (between 2003 and 2006) a total number of 1,392,427 children were screened for hearing impairment, what stands for 96.3% of all delivered babies, registered in Poland. The screening program enabled to identify and refer for further treatment 2485 children with various types of hearing loss, 312 with profound (0.02% of population) and 145 with severe sensorineural hearing loss (0.11% of population). Our results indicate the accuracy of newborn hearing screening which remain an issue. Although improvement is needed in both intervention systems and diagnostic follow-up of hospitals, the Polish Universal Neonatal Hearing Program fully has achieved the main goal, the identification and treatment of hearing impaired children.
Moodley, Selvarani; Störbeck, Claudine
2016-12-01
Within the Early Hearing Detection and Intervention (EHDI) pathway, which includes the processes of screening, diagnosis and intervention for paediatric hearing loss, paediatric diagnostic audiology involves a battery of specific tests and procedures. International studies have highlighted a golden standard for diagnosis of paediatric hearing loss as based on the Joint Committee of Infant Hearing (2007) diagnostic guidelines, closely resembling the HPCSA diagnostic guidelines. There are limited South African studies on the processes and protocols followed in diagnostic paediatric audiology. This study aims to provide a comparison for how the tests used for diagnosis of paediatric hearing loss in South Africa (within both the public and private healthcare sectors) compare to the HPCSA recommended diagnostic guidelines. A retrospective record review of paediatric clients with hearing loss (recruited through nonprobability convenience sampling) was conducted. This study is part of a longitudinal study of 711 deaf or hard of hearing children referred to the HI HOPES early intervention programme from September 2006 to December 2011. Diagnostic data from audiology reports of 117 children between 0 and 36 months were coded and analysed. Large variation was found in the tests included in the diagnostic audiology reports. For 22 children (19%) a comprehensive test battery was used. Health Professions Council of South Africa (HPCSA) recommended guidelines for diagnostic testing were not followed in any of the records analysed. Components of the HPCSA recommended test battery most frequently omitted was bone conduction testing. For both electrophysiology and behavioural testing, there was limited frequency specificity information. This exclusion of information is evidence of deficiencies in data recording and management, as well as having an effect on accuracy of classification of degree and type of hearing loss. There are gaps in age-appropriate assessment protocols, which will have an effect on accurate differential diagnosis of paediatric hearing loss. Reasons for not including all testing components of the HPCSA recommended guidelines, as well as the possibility of developing guidelines more relevant to a developing world context, should be explored. There might be a need for. The impact of South African specific factors that have an effect on provision of accurate paediatric diagnostic audiology services should be determined. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Screening Procedures Used to Identify Children with Hearing Loss.
ERIC Educational Resources Information Center
Barringer, Donald G.; And Others
1993-01-01
Analysis of data on 1,404 young children with hearing losses indicated that 80% of the children were identified via informal hearing-screening procedures, such as parental suspicion and referral. Auditory brainstem response technology provided the lowest mean identification age. The study concludes that formal screening programs are not locating…
Hearing loss in the developing world: evaluating the iPhone mobile device as a screening tool.
Peer, S; Fagan, J J
2015-01-01
Developing countries have the world's highest prevalence of hearing loss, and hearing screening programmes are scarce. Mobile devices such as smartphones have potential for audiometric testing. To evaluate the uHear app using an Apple iPhone as a possible hearing screening tool in the developing world, and to determine accuracy of certain hearing thresholds that could prove useful in early detection of hearing loss for high-risk populations in resource-poor communities. This was a quasi-experimental study design. Participants recruited from the Otolaryngology Clinic, Groote Schuur Hospital, Cape Town, South Africa, completed a uHear test in three settings--waiting room (WR), quiet roon (QR) and soundproof room (SR). Thresholds were compared with formal audiograms. Twenty-five patients were tested (50 ears). The uHear test detected moderate or worse hearing loss (pure-tone average (PTA) > 40 dB accurately with a sensitivity of 100% in all three environments. Specificity was 88% (SR), 73% (QR) and 68% (WR). Its was highly accurate in detecting high-frequency hearing loss (2 000, 4 000, 6 000 Hz) in the QR and SR with 'good' and 'very good' kappa values, showing statistical significance (p < 0.05). It was moderately accurate in low-frequency hearing loss (250, 500, 1 000 Hz) in the SR, and poor in the QR and WR. Using the iPhone, uHear is a feasible screening test to rule out significant hearing loss (PTA > 40 dB). It is highly sensitive for detecting threshold changes at high frequencies, making it reasonably well suited to detect presbycusis and ototoxic hearing loss from HIV, tuberculosis therapy and chemotherapy. Portability and ease of use make it appropriate to use in developing world communities that lack screening programmes.
Doyle, J; Wong, L L
1996-12-01
This paper addresses the observation that some Cantonese-speaking adults do not perceive a hearing problem even when hearing screening identifies hearing loss. A sample of 49 Cantonese speakers was surveyed about their self-perceptions of hearing prior to a 25 dB HTL pure-tone screening test. All 49 persons failed the screening test, yet 34 (69.4%) reported that they had no problems hearing during conversations. Persons who admitted hearing difficulties tended to have mean hearing levels in excess of 45 dB HTL. A number of hypotheses concerning cultural and linguistic influences are proposed as explanations for the apparent lack of significance of auditory sensitivity loss for some Cantonese speakers. Ways in which these hypotheses might be tested are suggested.
Antenatal factors modulate hearing screen failure risk in preterm infants.
Leung, Jocelyn C; Cifra, Christina L; Agthe, Alexander G; Sun, Chen-Chih J; Viscardi, Rose M
2016-01-01
The objective of this study was to characterise the effects of antenatal inflammatory factors and maternal therapies on neonatal hearing screen outcomes in very low birthweight infants. We conducted a retrospective study of a cohort of infants <33 weeks' gestational age and <1501 g birth weight prospectively enrolled between 1999 and 2003 for whom placental pathology, cord blood interleukin (IL) 6, IL-1ß, tumour necrosis factor-α and neonatal hearing screen results were available. Of 289 infants with documented hearing screen results, 244 (84%) passed and 45 (16%) failed the hearing screen (unilateral, N=25 (56%); bilateral, N=20 (44%)). In the final logistic model, the fetal inflammatory response syndrome defined as the presence of fetal vasculitis and/or cord serum IL-6>18.2 pg/mL was the factor with greatest risk for hearing screen failure (OR 3.62, 95% CI 1.38 to 9.5). A patent ductus arteriosus treated with indomethacin significantly increased the risk (OR 3.3, 95% CI 1.3 to 8.26), while combined maternal steroid and magnesium sulfate exposure (0.37, 95% CI 0.11 to 0.81) reduced the risk for hearing screen failure. Intrauterine infection with a fetal inflammatory response is a risk factor for neonatal hearing loss while maternal therapies significantly reduced the risk of neonatal hearing loss in very low birthweight infants. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Vancor, Emily; Shapiro, Eugene D; Loyal, Jaspreet
2018-01-24
Congenital cytomegalovirus (CMV) infection is a major cause of sensorineural hearing loss. By law, newborns in Connecticut who fail newborn hearing screening are tested for infection with CMV. This targeted screening is controversial, because most children with congenital CMV infection are asymptomatic, and CMV-related hearing loss can have a delayed onset. Our hospital uses a saliva polymerase chain reaction (PCR) assay (confirmed by a urine PCR assay) to detect CMV. Here, we report the results of the first year of our screening program. We reviewed the medical records of newborns in the Yale New Haven Health System who failed the newborn hearing screening test between January 1 and December 31, 2016. Of 10964 newborns, 171 failed newborn hearing screening, and 3 of these newborns had positive saliva CMV PCR test results. Of these 3 newborns, 2 had positive results on the confirmatory test (for 1 of them the confirmatory test was not performed until the infant was 10 weeks old), and 1 had a negative result on the confirmatory test. Three additional newborns with congenital CMV infection were tested because of clinical indications (1 for ventriculomegaly on prenatal ultrasound and 2 for CMV infection of the mother). Results of audiology follow-up were available for 149 (87.1%) of the 171 newborns who failed newborn hearing screening; 127 (85.2%) had normal results. Our targeted screening program for congenital CMV infection had a low yield. Consideration should be given to other strategies for identifying children at risk of hearing loss as a result of congenital CMV infection. © The Author(s) 2018. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Núñez-Batalla, Faustino; Antuña-León, Eva; González-Trelles, Teresa; Carro-Fernández, Pilar
2009-01-01
Although measuring parent satisfaction has been recommended as one of the important outcome measures in assessing the effectiveness of neonatal hearing screening programs, there are few published studies investigating this issue. To validate the Spanish version of the Parent Satisfaction Questionnaire with Neonatal Hearing Screening Program (PSQ-NHSP). 112 parents whose children had received hearing screening participated in this study. High levels of satisfaction were reported with more than 90% of parents satisfied with all aspects of the program. The psychometric properties of the Spanish version of the PSQ-NHSP were analyzed and demonstrated good internal consistency (alpha=0.75). Construct validity was indicated by a significant positive relationship between overall satisfaction and the three specific dimensions in the questionnaire. The development of a valid and reliable parent satisfaction questionnaire is important for improving hearing screening programs.
Conference on Newborn Hearing Screening; Proceedings Summary and Recommendations.
ERIC Educational Resources Information Center
Alexander Graham Bell Association for the Deaf, Inc., Washington, DC.
Presented in the conference proceedings are schedule and list of participants, seven major papers, and the newborn hearing screening recommendations of the interdisciplinary conference on newborn hearing and early identification of hearing impairment. Neonatal auditory testing is reviewed by Sanford E. Gerber, and Sheldon B. Korones gives a…
Screening for Vision Problems in Children with Hearing Impairments.
ERIC Educational Resources Information Center
Demchak, MaryAnn; Elquist, Marty
Vision problems occur at higher rates in the deaf and hearing impaired population than in the general population. When an individual has a hearing impairment, vision becomes more significant in the instructional and learning process, as well as in social and communicative exchanges. Regular comprehensive visual screening of hearing impaired…
Poonual, Watcharapol; Navacharoen, Niramon; Kangsanarak, Jaran; Namwongprom, Sirianong
2016-01-01
Objective To define the risk factors for hearing loss in infants (aged 3 months) under universal hearing screening program. Materials and methods A total of 3,120 infants (aged 3 months) who underwent hearing screening using a universal hearing screening program using automated otoacoustic emission test between November 1, 2010 and May 31, 2012 in Uttaradit Hospital, Buddhachinaraj Hospital, and Sawanpracharuk Hospital (tertiary hospitals) located in Northern Thailand were included in this prospective cohort study. Results Of the 3,120 infants, 135 (4.3%) were confirmed to have hearing loss with the conventional otoacoustic emission test. Five of these 135 infants (3.7%) with hearing loss showed test results consistent with auditory brainstem responses. From the univariable analysis, there were eleven potential risk factors associated with hearing deterioration. On multivariable analysis, the risk factors independently associated with hearing loss at 3 months were birth weight 1,500–2,500 g (risk ratio [RR] 1.6, 95% confidence interval [CI] 1.1–2.6), APGAR score <6 at 5 minutes (RR 2.2, 95% CI 1.1–4.4), craniofacial anomalies (RR 2.5, 95% CI 1.6–4.2), sepsis (RR 1.8, 95% CI 1.0–3.2), and ototoxic exposure (RR 4.1, 95% CI 1.9–8.6). Conclusion This study concluded that low birth weight, APGAR score <6 at 5 minutes, craniofacial anomalies, sepsis, and ototoxic exposure are the risk factors for bilateral hearing loss in infants (aged 3 months) and proper tests should be performed to identify these risk factors. As an outcome, under the present circumstances, it is suggested that infirmary/physicians/general practitioners/health action centers/polyclinics should carry out universal hearing screening in all infants before 36 weeks. The public health policy of Thailand regarding a universal hearing screening program is important for the prevention of disability and to enhance people’s quality of life. PMID:26766912
Feasibility of a low-cost hearing screening in rural Indiana.
Khan, Khalid M; Bielko, Sylvanna L; Barnes, Priscilla A; Evans, Sydney S; Main, Anna L K
2017-09-18
Hearing loss remains a neglected public health issue in the rural and agricultural communities in the United States and therefore, promotion of a low-cost hearing screening may be important for these underserved populations. The major objectives of our study were to assess feasibility of a low-cost telephone-administered hearing test in rural Indiana and to identify the challenges, barriers and viable implementation strategies associated with this test. Also, we evaluated whether a focus group session could change the hearing health attitude of rural residents. We recruited 126 adults from six rural Indiana counties who participated in study activities in the following order: 1) a pre-focus group demographic, knowledge and attitude survey, 2) a focus group for discussing the feasibility of a telephone-administered hearing screening, 3) a post focus group attitude survey and 4) hearing was screened using an audiometer and self-assessment scale. These activities generated both qualitative and quantitative data, which were subsequently analyzed. Hearing impairment was perceived as an important public health issue. Many participants expressed interests to try the low-cost National Hearing Test (NHT). However, participants recommended NHT to be facilitated by community organizations to provide access to landline phones. The focus group turned out to be an excellent awareness building activity producing significant improvement in hearing health attitudes. Comparison of self and audiometric evaluations indicated underestimation of hearing handicap in our rural study population. The study results underscore the urgent need for an effective strategy to promote low-cost hearing screening in rural US communities.
Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia
2014-01-01
This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: "a hearing check is recommended" (red light), "a hearing check would be advisable" (yellow light), and "no hearing difficulties" (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.
The economics of screening infants at risk of hearing impairment: an international analysis.
Burke, Martyn J; Shenton, Ruth C; Taylor, Matthew J
2012-02-01
Hearing impairment in children across the world constitutes a particularly serious obstacle to their optimal development and education, including language acquisition. Around 0.5-6 in every 1000 neonates and infants have congenital or early childhood onset sensorineural deafness or severe-to-profound hearing impairment, with significant consequences. Therefore, early detection is a vitally important element in providing appropriate support for deaf and hearing-impaired babies that will help them enjoy equal opportunities in society alongside all other children. This analysis estimates the costs and effectiveness of various interventions to screen infants at risk of hearing impairment. The economic analysis used a decision tree approach to determine the cost-effectiveness of newborn hearing screening strategies. Two unique models were built to capture different strategic screening decisions. Firstly, the cost-effectiveness of universal newborn hearing screening (UNHS) was compared to selective screening of newborns with risk factors. Secondly, the cost-effectiveness of providing a one-stage screening process vs. a two-stage screening process was investigated. Two countries, the United Kingdom and India, were used as case studies to illustrate the likely cost outcomes associated with the various strategies to diagnose hearing loss in infants. In the UK, the universal strategy incurs a further cost of approximately £2.3 million but detected an extra 63 cases. An incremental cost per case detected of £36,181 was estimated. The estimated economic burden was substantially higher in India when adopting a universal strategy due to the higher baseline prevalence of hearing loss. The one-stage screening strategy accumulated an additional 13,480 and 13,432 extra cases of false-positives, in the UK and India respectively when compared to a two-stage screening strategy. This represented increased costs by approximately £1.3 million and INR 34.6 million. The cost-effectiveness of a screening intervention was largely dependent upon two key factors. As would be expected, the cost (per patient) of the intervention drives the model substantially, with higher costs leading to higher cost-effectiveness ratios. Likewise, the baseline prevalence (risk) of hearing impairment also affected the results. In scenarios where the baseline risk was low, the intervention was less likely to be cost-effective compared to when the baseline risk was high. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Screening Newborns | NIH MedlinePlus the Magazine
... signed the Newborn and Infant Hearing Screening and Intervention Act, authorizing the coordination and funding of statewide ... hearing loss before they leave the hospital. → Early interventions and treatments (hearing aids, cochlear implants, sign language, ...
Parents' preferences for services for children with hearing loss: a conjoint analysis study.
Fitzpatrick, Elizabeth; Coyle, Douglas E; Durieux-Smith, Andrée; Graham, Ian D; Angus, Douglas E; Gaboury, Isabelle
2007-12-01
Early identification of permanent childhood hearing loss through universal newborn hearing screening is rapidly becoming a standard of care. However, it is well recognized that hearing screening must be embedded within a comprehensive system of rehabilitation and parent support services. This study was undertaken with parents of young children with permanent hearing loss to examine their preferences for characteristics associated with intervention services. A secondary goal was to explore whether preferences may differ according to patient subgroups. Conjoint analysis, a preference-based economic technique, was used to investigate parents' strength of preferences. A cross-sectional survey that consisted of hypothetical clinic scenarios was developed based on information from qualitative interviews with parents. The questionnaire was administered to parents receiving intervention services in the province of Ontario, Canada, shortly after the implementation of a universal hearing screening program. The sample was recruited from three different clinical programs. A total of 48 of 75 respondents completed the questionnaire, a response rate of 64%. The participants varied by screening status of the child (25 screened, 23 not screened), type of device (23 hearing aids, 25 cochlear implants), and region. All five characteristics of care that were selected for inclusion in the survey were found to be statistically significant attributes of services: coordinated services, access to parent support, access to information, frequency of services, and location of services. Parents showed a preference for clinic-based rather than home-based services. Preferences toward once a week therapy services rather than services two to three times weekly were also found. In particular, parents valued service models that consisted of well-coordinated care with access to support from other parents. Differences in respondents according to hearing screening status (screened or unscreened), type of hearing device (hearing aid or cochlear implant), or region (Ottawa or Toronto) did not seem to affect parents' preferences for attributes of care. Conjoint analysis is a useful technique for quantifying parents' preferences for care. The values expressed by parents provide insights into the aspects of a service model that should receive consideration in the development of programs for young children with hearing loss and their families.
Certified School Nurse Perspectives on State-Mandated Hearing Screens
ERIC Educational Resources Information Center
Sekhar, Deepa L.; Beiler, Jessica S.; Schaefer, Eric W.; Henning, Antoinette; Dillon, Judith F.; Czarnecki, Beth; Zalewski, Thomas R.
2016-01-01
Background: Approximately 15% of children in the United States 6-19 years of age have hearing loss. Even mild, unilateral hearing loss may adversely affect educational success. In 2014, the Pennsylvania Department of Health (PA DOH) began updating the 2001 regulations on state-mandated school hearing screens. To inform the updates, a needs…
2013-01-01
Background Given that hearing loss occurs in 1 to 3 of 1,000 live births and approximately 90 to 95 percent of them are born into hearing families, it is of importance and necessity to get better understanding about the carrier rate and mutation spectrum of genes associated with hearing impairment in the general population. Methods 7,263 unrelated women of childbearing age with normal hearing and without family history of hearing loss were tested with allele-specific PCR-based universal array. Further genetic testing were provided to the spouses of the screened carriers. For those couples at risk, multiple choices were provided, including prenatal diagnosis. Results Among the 7,263 normal hearing participants, 303 subjects carried pathogenic mutations included in the screening chip, which made the carrier rate 4.17%. Of the 303 screened carriers, 282 harbored heterozygous mutated genes associated with autosomal recessive hearing loss, and 95 spouses took further genetic tests. 8 out of the 9 couples harbored deafness-causing mutations in the same gene received prenatal diagnosis. Conclusions Given that nearly 90 to 95 percent of deaf and hard-of-hearing babies are born into hearing families, better understanding about the carrier rate and mutation spectrum of genes associated with hearing impairment in the female population of childbearing age may be of importance in carrier screening and genetic counseling. PMID:23718755
Yin, Aihua; Liu, Chang; Zhang, Yan; Wu, Jing; Mai, Mingqin; Ding, Hongke; Yang, Jiexia; Zhang, Xiaozhuang
2013-05-29
Given that hearing loss occurs in 1 to 3 of 1,000 live births and approximately 90 to 95 percent of them are born into hearing families, it is of importance and necessity to get better understanding about the carrier rate and mutation spectrum of genes associated with hearing impairment in the general population. 7,263 unrelated women of childbearing age with normal hearing and without family history of hearing loss were tested with allele-specific PCR-based universal array. Further genetic testing were provided to the spouses of the screened carriers. For those couples at risk, multiple choices were provided, including prenatal diagnosis. Among the 7,263 normal hearing participants, 303 subjects carried pathogenic mutations included in the screening chip, which made the carrier rate 4.17%. Of the 303 screened carriers, 282 harbored heterozygous mutated genes associated with autosomal recessive hearing loss, and 95 spouses took further genetic tests. 8 out of the 9 couples harbored deafness-causing mutations in the same gene received prenatal diagnosis. Given that nearly 90 to 95 percent of deaf and hard-of-hearing babies are born into hearing families, better understanding about the carrier rate and mutation spectrum of genes associated with hearing impairment in the female population of childbearing age may be of importance in carrier screening and genetic counseling.
Prediction of permanent hearing loss in high-risk preterm infants at term age.
Valkama, A M; Laitakari, K T; Tolonen, E U; Väyrynen, M R; Vainionpää, L K; Koivisto, M E
2000-06-01
The aim of this series was to assess hearing screenings; auditory brainstem responses (ABR), transient evoked otoacoustic emissions (TEOAE) and free field auditory responses (FF) for the prediction of permanent bilateral hearing loss in high-risk preterm infants at term post-conceptional age. A total of 51 preterm infants (gestational age < 34 weeks, birth weight < 1500 g) underwent examinations at term and hearing, speech and neurological development were followed up until a corrected age of 18 months. Significant hearing defects were verified by broader ABR examinations under sedation and by clinical ward observation including responsiveness to sounds and enhancement of hearing using an amplification device. Seven bilateral fails in ABR were found, together with nine bilateral fails in TEOAE and four fails in FF screening at term age. Six preterm infants were later confirmed to have a significant permanent bilateral hearing loss, four of whom had also cerebral palsy. Bilateral failure in ABR screening predicted hearing loss with a sensitivity of 100% and a specificity of 98%, TEOAE with a sensitivity of 50% and a specificity of 84% and in the FF examination at the levels of 50% and 98%, respectively. Transient evoked otoacoustic emissions alone seem not to be so applicable to the neonatal screening of hearing in high-risk preterm infants as shown earlier in full-term infants, possibly because a hearing defect may be due to retrocochlear damage. Consequently, auditory brainstem response screening seems to be more suitable for very low birth weight preterm infants.
Auditory brainstem response screening for hearing loss in high risk neonates.
Watson, D R; McClelland, R J; Adams, D A
1996-07-01
The present paper reports the findings of a 7 year study evaluating the use of the auditory brainstem response (ABR) as the basis of a hearing screening procedure in a group of newborns at increased risk of hearing impairment. A Special Care Baby Unit (SCBU) population of 417 infants with diverse clinical backgrounds and treatment histories was tested for hearing impairment at birth using ABR audiometry. Some 332 passed the original screen at 30 dBnHL test level in both ears. Of the failure group, 18 did not survive and 32 had some degree of hearing impairment confirmed, nine of which were sensorineural in origin. An increased incidence of persistent middle ear disease was also noted in the failure group. A detailed operational analysis demonstrates that provided appropriate pass/fail criteria are adopted, the ABR technique offers excellent sensitivity and specificity for the detection of significant hearing loss in the test population. Furthermore, the study establishes that implementation of an ABR-based screening programme could reduce the average age at detection of permanent hearing loss by 7 months. A cost assessment shows that the introduction of such a targetted screening procedure could be done at a reasonable outlay.
Impact of Co-Occurring Birth Defects on the Timing of Newborn Hearing Screening and Diagnosis
Chapman, Derek A.; Stampfel, Caroline C.; Bodurtha, Joann N.; Dodson, Kelley M.; Pandya, Arti; Lynch, Kathleen B.; Kirby, Russell S.
2016-01-01
Purpose Early detection of hearing loss in all newborns and timely intervention are critical to children's cognitive, verbal, behavioral, and social development. The initiation of appropriate early intervention services before 6 months of age can prevent or reduce negative developmental consequences. The purpose of this study was to assess, using large, population-based registries, the effect of co-occurring birth defects (CBDs) on the timing and overall rate of hearing screening and diagnosis. Method The authors linked statewide data from newborn hearing screenings, a birth defects registry, and birth certificates to assess the timeliness of newborn hearing screening and diagnosis of hearing loss (HL) for infants with and without CBDs in 485 children with confirmed HL. Results Nearly one third (31.5%) of children with HL had 1 or more CBDs. The presence of CBDs prolonged the time of the initial infant hearing screening, which contributed to further delays in the subsequent diagnosis of HL. Conclusions Better coordination of HL assessment into treatment plans for children with CBDs may enable earlier diagnosis of HL and provide opportunities for intervention that will affect long-term developmental outcomes for these children. PMID:21940980
Consensus Statement of the Indian Academy of Pediatrics on Newborn Hearing Screening.
Paul, Abraham; Prasad, Chhaya; Kamath, S S; Dalwai, Samir; C Nair, M K; Pagarkar, Waheeda
2017-08-15
Hearing impairment is one of the most critical sensory impairments with significant social and psychological consequences. Evidence-based, standardized national guidelines are needed for professionals to screen for hearing impairment during the neonatal period. The meeting on formulation of national consensus guidelines on developmental disorders was organized by Indian Academy of Pediatrics in Mumbai, on 18th and 19th December, 2015. The invited experts included Pediatricians, Developmental Pediatricians, Pediatric Neurologists and Clinical Psychologists. The participants framed guidelines after extensive discussions. To provide guidelines on newborn hearing screening in India. The first screening should be conducted before the neonate's discharge from the hospital - if it 'fails', then it should be repeated after four weeks, or at first immunization visit. If it 'fails' again, then Auditory Brainstem Response (ABR) audiometry should be conducted. All babies admitted to intensive care unit should be screened via ABR. All babies with abnormal ABR should undergo detailed evaluation, hearing aid fitting and auditory rehabilitation, before six months of age. The goal is to screen newborn babies before one month of age, diagnose hearing loss before three months of age and start intervention before six months of age.
Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia
2014-01-01
This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: “a hearing check is recommended” (red light), “a hearing check would be advisable” (yellow light), and “no hearing difficulties” (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention. PMID:25247181
Auditory fitness for duty: a review.
Tufts, Jennifer B; Vasil, Kristin A; Briggs, Sarah
2009-10-01
Auditory fitness for duty (AFFD) refers to the possession of hearing abilities sufficient for safe and effective job performance. In jobs such as law enforcement and piloting, where the ability to hear is critical to job performance and safety, hearing loss can decrease performance, even to the point of being hazardous to self and others. Tests of AFFD should provide an employer with a valid assessment of an employee's ability to perform the job safely, without discriminating against the employee purely on the basis of hearing loss. The purpose of this review is to provide a basic description of the functional hearing abilities required in hearing-critical occupations, and a summary of current practices in AFFD evaluation. In addition, we suggest directions for research and standardization to ensure best practices in the evaluation of AFFD in the future. We conducted a systematic review of the English-language peer-reviewed literature in AFFD. "Popular" search engines were consulted for governmental regulations and trade journal articles. We also contacted professionals with expertise in AFFD regarding research projects, unpublished material, and current standards. The literature review provided information regarding the functional hearing abilities required to perform hearing-critical tasks, the development of and characteristics of AFFD protocols, and the current implementation of AFFD protocols. This review paper provides evidence of the need to institute job-specific AFFD protocols, move beyond the pure-tone audiogram, and establish the validity of test protocols. These needs are arguably greater now than in times past.
The Benefit of Remote Microphones Using Four Wireless Protocols.
Rodemerk, Krishna S; Galster, Jason A
2015-09-01
Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearing aids. As a result, commercial remote microphone systems use a variety of different protocols for wireless audio transmission. It is not known how these systems compare, with regard to adult speech recognition in noise. The primary goal of this investigation was to determine the speech recognition benefits of four different commercially available remote microphone systems, each with a different wireless audio transmission protocol. A repeated-measures design was used in this study. Sixteen adults, ages 52 to 81 yr, with mild to severe sensorineural hearing loss participated in this study. Participants were fit with three different sets of bilateral hearing aids and four commercially available remote microphone systems (FM, 900 MHz, 2.4 GHz, and Bluetooth(®) paired with near-field magnetic induction). Speech recognition scores were measured by an adaptive version of the Hearing in Noise Test (HINT). The participants were seated both 6 and 12' away from the talker loudspeaker. Participants repeated HINT sentences with and without hearing aids and with four commercially available remote microphone systems in both seated positions with and without contributions from the hearing aid or environmental microphone (24 total conditions). The HINT SNR-50, or the signal-to-noise ratio required for correct repetition of 50% of the sentences, was recorded for all conditions. A one-way repeated measures analysis of variance was used to determine statistical significance of microphone condition. The results of this study revealed that use of the remote microphone systems statistically improved speech recognition in noise relative to unaided and hearing aid-only conditions across all four wireless transmission protocols at 6 and 12' away from the talker. Participants showed a significant improvement in speech recognition in noise when comparing four remote microphone systems with different wireless transmission methods to hearing aids alone. American Academy of Audiology.
Rastogi, Shantanu; Mikhael, Michel; Filipov, Panayot; Rastogi, Deepa
2013-03-01
There is increased risk of hearing loss in preterm neonates. This risk is further increased by environmental noise exposure especially from life support equipment such as ventilation. Nasal continuous positive airway pressure (NCPAP) used for respiratory support of preterm neonates is known to be associated with prolonged exposure to high levels of noise. However, there is paucity of information on the effect of NCPAP as compared to mechanical ventilation on hearing loss among preterm neonates. A retrospective chart review was performed on neonates with birth weight (BW) <1500g. Association of clinical factors including the use of NCPAP and mechanical ventilation with failure of hearing screen were studied. Those who failed hearing screen were followed for 2 years to observe long term effects of NCPAP on the hearing loss. Of 344 neonates included in the study, 61 failed hearing screen. Gestational age (p=0.008), BW (p=0.03), ventilation (p=0.02), intrauterine growth retardation (p=0.02), necrotizing enterocolitis (NEC) (p=0.02), apnea (p<0.001), use of vancomycin (p=0.01) and furosemide (p=0.01) were associated with failure of hearing screen. On multivariate analysis, ventilation (OR 4.56, p=0.02), apnea (OR 2.2, p<0.001) and NEC (OR 2.4, p=0.02) were predictors of failed hearing screen. As compared to those not ventilated, the odds of failing hearing screen was 4.53 (p<0.01) and 4.59 (p<0.01) for those treated with NCPAP and mechanical ventilation respectively, with there being no difference between these two ventilatory modalities. Of the 61 neonates, 42 were followed for 2 years, of which 19 had confirmed hearing loss. Among these 19 neonates, there was no difference (p=0.12) between those who were treated with NCPAP or with mechanical ventilation. There is no increase in the hearing loss in preterm neonates treated with NCPAP as compared to mechanical ventilation despite being exposed to higher environmental noise generated by the NCPAP. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Aithal, Sreedevi; Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie
2012-10-01
Although newborn hearing screening programs have been introduced in most states in Australia, the prevalence of conductive hearing loss and middle ear pathology in the infants referred through these programs is not known. This study was designed to (1) evaluate the prevalence of conductive hearing loss and middle ear pathology in infants referred by a newborn hearing screening program in north Queensland, (2) compare prevalence rates of conductive hearing loss and middle ear pathology in indigenous and nonindigenous infants, and (3) review the outcomes of those infants diagnosed with conductive hearing loss and middle ear pathology. Retrospective chart review of infants referred to the Audiology Department of The Townsville Hospital was conducted. Chart review of 234 infants referred for one or both ears from a newborn hearing screening program in north Queensland was conducted. A total of 211 infants attended the diagnostic appointment. Review appointments to monitor hearing status were completed for 46 infants with middle ear pathology or conductive hearing loss. Diagnosis of hearing impairment was made using an age-appropriate battery of audiological tests. Results were analyzed for both initial and review appointments. Mean age at initial diagnostic assessment was 47.5 days (SD = 31.3). Of the 69 infants with middle ear pathology during initial diagnostic assessment, 18 had middle ear pathology with normal hearing, 47 had conductive hearing loss, and 4 had mixed hearing loss. Prevalence of conductive hearing loss in the newborns was 2.97 per 1,000 while prevalence of middle ear pathology (with or without conductive hearing loss) was 4.36 per 1,000. Indigenous Australians or Aboriginal and Torres Strait Islander (ATSI) infants had a significantly higher prevalence of conductive hearing loss and middle ear pathology than non-ATSI infants (35.19 and 44.45% vs 17.83 and 28.66%, respectively). ATSI infants also showed poor resolution of conductive hearing loss over time with 66.67% of ATSI infants reviewed showing persistent conductive hearing loss compared to 17.86% of non-ATSI infants. Medical management of 17 infants with persistent conductive hearing loss included monitoring, antibiotic treatment, examination under anesthesia, and grommet insertion. Conductive hearing loss was found to be a common diagnosis among infants referred through screening. ATSI infants had significantly higher rates of middle ear pathology and conductive hearing loss at birth and showed poor resolution of middle ear pathology over time compared to non-ATSI infants. Future research using a direct measure of middle ear function as an adjunct to the automated auditory brainstem response screening tool to distinguish conductive from sensorineural hearing loss may facilitate prioritization of infants for assessment, thus reducing parental anxiety and streamlining the management strategies for the respective types of hearing loss. American Academy of Audiology.
ERIC Educational Resources Information Center
Shannon, Dorothy A.; And Others
1984-01-01
The brainstem auditory evoked potential (BAEP) was evaluated as a hearing screening test in 168 high-risk newborns. The BAEP was found to be a sensitive procedure for the early identification of hearing-impaired newborns. However, the yield of significant hearing abnormalities was less than predicted in other studies using BAEP. (Author/CL)
Göpel, Wolfgang; Berkowski, Sandra; Preuss, Michael; Ziegler, Andreas; Küster, Helmut; Felderhoff-Müser, Ursula; Gortner, Ludwig; Mögel, Michael; Härtel, Christoph; Herting, Egbert
2014-08-26
The mitochondrial m.1555A>G mutation is associated with a high rate of permanent hearing loss, if aminoglycosides are given. Preterm infants have an increased risk of permanent hearing loss and are frequently treated with aminoglycoside antibiotics. We genotyped preterm infants with a birth weight below 1500 grams who were prospectively enrolled in a large cohort study for the m.1555A>G mutation. Treatment with aminoglycoside antibiotics in combination with mitochondrial m.1555A>G mutation was tested as a predictor for failed hearing screening at discharge in a multivariate logistic regression analysis. 7056 infants were genotyped and analysed. Low birth weight was the most significant predictor of failed hearing screening (p = 7.3 × 10-10). 12 infants (0.2%) had the m.1555A>G-mutation. In a multivariable logistic regression analysis, the combination of aminoglycoside treatment with m.1555A>G-carrier status was associated with failed hearing screening (p = 0.0058). However, only 3 out of 10 preterm m.1555A>G-carriers who were exposed to aminoglycosides failed hearing screening. The m.1555A>G-mutation was detected in all mothers of m.1555A>G-positive children, but in none of 2993 maternal DNA-samples of m.1555A>G-negative infants. Antenatal screening for the m.1555A>G mutation by maternal genotyping of pregnant women with preterm labour might be a reasonable approach to identify infants who are at increased risk for permanent hearing loss. Additional studies are needed to estimate the relevance of cofactors like aminoglycoside plasma levels and birth weight and the amount of preterm m.1555A>G-carriers with permanent hearing loss.
2014-01-01
Background The mitochondrial m.1555A>G mutation is associated with a high rate of permanent hearing loss, if aminoglycosides are given. Preterm infants have an increased risk of permanent hearing loss and are frequently treated with aminoglycoside antibiotics. Methods We genotyped preterm infants with a birth weight below 1500 grams who were prospectively enrolled in a large cohort study for the m.1555A>G mutation. Treatment with aminoglycoside antibiotics in combination with mitochondrial m.1555A>G mutation was tested as a predictor for failed hearing screening at discharge in a multivariate logistic regression analysis. Results 7056 infants were genotyped and analysed. Low birth weight was the most significant predictor of failed hearing screening (p = 7.3 × 10-10). 12 infants (0.2%) had the m.1555A>G-mutation. In a multivariable logistic regression analysis, the combination of aminoglycoside treatment with m.1555A>G-carrier status was associated with failed hearing screening (p = 0.0058). However, only 3 out of 10 preterm m.1555A>G-carriers who were exposed to aminoglycosides failed hearing screening. The m.1555A>G-mutation was detected in all mothers of m.1555A>G-positive children, but in none of 2993 maternal DNA-samples of m.1555A>G-negative infants. Conclusion Antenatal screening for the m.1555A>G mutation by maternal genotyping of pregnant women with preterm labour might be a reasonable approach to identify infants who are at increased risk for permanent hearing loss. Additional studies are needed to estimate the relevance of cofactors like aminoglycoside plasma levels and birth weight and the amount of preterm m.1555A>G-carriers with permanent hearing loss. PMID:25155176
Enhancing Ear and Hearing Health Access for Children With Technology and Connectivity.
Swanepoel, De Wet
2017-10-12
Technology and connectivity advances are demonstrating increasing potential to improve access of service delivery to persons with hearing loss. This article demonstrates use cases from community-based hearing screening and automated diagnosis of ear disease. This brief report reviews recent evidence for school- and home-based hearing testing in underserved communities using smartphone technologies paired with calibrated headphones. Another area of potential impact facilitated by technology and connectivity is the use of feature extraction algorithms to facilitate automated diagnosis of most common ear conditions from video-otoscopic images. Smartphone hearing screening using calibrated headphones demonstrated equivalent sensitivity and specificity for school-based hearing screening. Automating test sequences with a forced-choice response paradigm allowed persons with minimal training to offer screening in underserved communities. The automated image analysis and diagnosis system for ear disease demonstrated an overall accuracy of 80.6%, which is up to par and exceeds accuracy rates previously reported for general practitioners and pediatricians. The emergence of these tools that capitalize on technology and connectivity advances enables affordable and accessible models of service delivery for community-based ear and hearing care.
Ingo, Elisabeth; Brännström, K Jonas; Andersson, Gerhard; Lunner, Thomas; Laplante-Lévesque, Ariane
2016-07-01
Acceptance and readiness to seek professional help have shown to be important factors for favourable audiological rehabilitation outcomes. Theories from health psychology such as the transtheoretical (stages-of-change) model could help understand behavioural change in people with hearing impairment. In recent studies, the University of Rhode Island change assessment (URICA) has been found to have good predictive validity. In a previous study, 224 Swedish adults who had failed an online hearing screening completed URICA and two other measures of stages of change. This follow-up aimed to: (1) determine prevalence of help-seeking at a hearing clinic and hearing aid uptake, and (2) explore the predictive validity of the stages of change measures by a follow-up on the 224 participants who had failed a hearing screening 18 months previously. A total of 122 people (54%) completed the follow-up online questionnaire, including the three measures and questions regarding experience with hearing help-seeking and hearing aid uptake. Since failing the online hearing screening, 61% of participants had sought help. A good predictive validity for a one-item measure of stages of change was reported. The Staging algorithm was the stages of change measure with the best ability to predict help-seeking 18 months later.
Lim, Magdalene Yeok Leng; Loo, Jenny Hooi Yin
2018-07-01
To determine if there is an association between hearing loss and poorer cognitive scores on Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA) and to determine if poor hearing acuity affects scoring on the cognitive screening tests of MMSE and MoCA. One hundred fourteen elderly patients (Singapore residents) aged between 55 and 86 years were sampled. Participants completed a brief history questionnaire, pure tone audiometry, and 2 cognitive screening tests-the MMSE and MoCA. Average hearing thresholds of the better ear in the frequencies of 0.5, 1, 2, and 4 kHz were used for data analysis. Hearing loss was significantly associated with poorer cognitive scores in Poisson regression models adjusted for age. Mini-Mental State Examination scores were shown to decrease by 2.8% (P = .029), and MoCA scores by 3.5% (P = .013) for every 10 dB of hearing loss. Analysis of hearing-sensitive components of "Registration" and "Recall" in MMSE and MoCA using chi-square tests showed significantly poorer performance in the hearing loss group as compared to the normal hearing group. Phonetic analysis of target words with high error rates shows that the poor performance was likely contributed by decreased hearing acuity, on top of a possible true deficit in cognition in the hearing impaired. Hearing loss is associated with poorer cognitive scores on MMSE and MoCA, and cognitive scoring is likely confounded by poor hearing ability. This highlights an important, often overlooked aspect of sensory impairment during cognitive screening. Provisions should be made when testing for cognition in the hearing-impaired population to avoid over-referral and subsequent misdiagnoses of cognitive impairment. Copyright © 2018 John Wiley & Sons, Ltd.
Periodic Early Childhood Hearing Screening: The EHDI Perspective
ERIC Educational Resources Information Center
Hoffman, Jeff; Houston, K. Todd; Munoz, Karen F.; Bradham, Tamala S.
2011-01-01
State coordinators of early hearing detection and intervention (EHDI) programs completed a strengths, weaknesses, opportunities, and threats, or SWOT, analysis that examined 12 areas within state EHDI programs. Concerning periodic early childhood hearing screening, 47 coordinators listed 241 items and themes were identified within each SWOT…
Roets-Merken, Lieve M; Zuidema, Sytse U; Vernooij-Dassen, Myrra J F J; Kempen, Gertrudis I J M
2014-11-01
This study investigated the psychometric properties of the Severe Dual Sensory Loss screening tool, a tool designed to help nurses and care assistants to identify hearing, visual and dual sensory impairment in older adults. Construct validity of the Severe Dual Sensory Loss screening tool was evaluated using Crohnbach's alpha and factor analysis. Interrater reliability was calculated using Kappa statistics. To evaluate the predictive validity, sensitivity and specificity were calculated by comparison with the criterion standard assessment for hearing and vision. The criterion used for hearing impairment was a hearing loss of ≥40 decibel measured by pure-tone audiometry, and the criterion for visual impairment was a visual acuity of ≤0.3 diopter or a visual field of ≤0.3°. Feasibility was evaluated by the time needed to fill in the screening tool and the clarity of the instruction and items. Prevalence of dual sensory impairment was calculated. A total of 56 older adults receiving aged care and 12 of their nurses and care assistants participated in the study. Crohnbach's alpha was 0.81 for the hearing subscale and 0.84 for the visual subscale. Factor analysis showed two constructs for hearing and two for vision. Kappa was 0.71 for the hearing subscale and 0.74 for the visual subscale. The predictive validity showed a sensitivity of 0.71 and a specificity of 0.72 for the hearing subscale; and a sensitivity of 0.69 and a specificity of 0.78 for the visual subscale. The optimum cut-off point for each subscale was score 1. The nurses and care assistants reported that the Severe Dual Sensory Loss screening tool was easy to use. The prevalence of hearing and vision impairment was 55% and 29%, respectively, and that of dual sensory impairment was 20%. The Severe Dual Sensory Loss screening tool was compared with the criterion standards for hearing and visual impairment and was found a valid and reliable tool, enabling nurses and care assistants to identify hearing, visual and dual sensory impairment among older adults. Copyright © 2014 Elsevier Ltd. All rights reserved.
[Newborn hearing screening program: association between hearing loss and risk factors].
Pereira, Priscila Karla Santana; Martins, Adriana de Souza; Vieira, Márcia Ribeiro; Azevedo, Marisa Frasson de
2007-01-01
Hearing loss in newborns. To verify the prevalence of auditory alterations in newborns of Hospital São Paulo (hospital), observing if there are any correlations with the following variables: birth weight, gestational age, relation weight/gestational age and risk factors for hearing loss. A retrospective analysis of the hospital records of 1696 newborns; 648 records of preterm infants and 1048 records of infants born at term. All of the infants had been submitted to an auditory evaluation consisting of: Transient Otoacoustic Emissions, investigation of the cochleal-palpebral reflexes and acoustic imittance tests, identifying the type and level of hearing loss. Sensorineural hearing loss was identified in .82% of the infants who were born at term and in 3.1% of the preterm infants -- with a statistically significant difference. Conductive hearing loss was the most frequent type of hearing loss in both groups, occurring in 14.6% of the term infants and in 16.3% of the preterm infants. Alteration of the central auditory system was considered as a possible diagnosis for 5.8% of the preterm infants and for 3.3% of the term infants. For the group of infants who were born at term, a significant correlation was observed between failure in the hearing screening test and the presence of risk factors such as family history and presence of a syndrome -- the child who presented a syndrome had 37 times more chances of failing in the hearing screening test and seven times more chances of failing in the right ear when there was a family history for hearing loss. The lower the gestational age (< 30 weeks) and birth weight (< 1500 g), the higher the chances of failing in the hearing screening test (3 times more). Hearing loss had a higher occurrence in preterm infants who remained in the ICU. Gestational age and birth weight were important variables related to the possibility of failure in the hearing screening test. A correlation was observed between the presence of a syndrome and sensorineural hearing loss in infants who were born at term.
Stages of change in adults who have failed an online hearing screening.
Laplante-Lévesque, Ariane; Brännström, K Jonas; Ingo, Elisabeth; Andersson, Gerhard; Lunner, Thomas
2015-01-01
Hearing screening has been proposed to promote help-seeking and rehabilitation in adults with hearing impairment. However, some longitudinal studies point to low help-seeking and subsequent rehabilitation after a failed hearing screening (positive screening result). Some barriers to help-seeking and rehabilitation could be intrinsic to the profiles and needs of people who have failed a hearing screening. Theories of health behavior change could help to understand this population. One of these theories is the transtheoretical (stages-of-change) model of health behavior change, which describes profiles and needs of people facing behavior changes such as seeking help and taking up rehabilitation. According to this model, people go through distinct stages toward health behavior change: precontemplation, contemplation, action, and finally, maintenance. The present study describes the psychometric properties (construct validity) of the stages of change in adults who have failed an online hearing screening. Stages of change were measured with the University of Rhode Island Change Assessment (URICA). Principal component analysis is presented, along with cluster analysis. Internal consistency was investigated. Finally, relationships between URICA scores and speech-in-noise recognition threshold, self-reported hearing disability, and self-reported duration of hearing disability are presented. In total, 224 adults who had failed a Swedish online hearing screening test (measure of speech-in-noise recognition) completed further questionnaires online, including the URICA. A principal component analysis identified the stages of precontemplation, contemplation, and action, plus an additional stage, termed preparation (between contemplation and action). According to the URICA, half (50%) of the participants were in the preparation stage of change. The contemplation stage was represented by 38% of participants, while 9% were in the precontemplation stage. Finally, the action stage was represented by approximately 3% of the participants. Cluster analysis identified four stages-of-change clusters: they were named decision making (44% of sample), participation (28% of sample), indecision (16% of sample), and reluctance (12% of sample). The construct validity of the model was good. Participants who reported a more advanced stage of change had significantly greater self-reported hearing disability. However, participants who reported a more advanced stage of change did not have a significantly worse speech-in-noise recognition threshold or reported a significantly longer duration of hearing impairment. The additional stage this study uncovered, and which other studies have also uncovered, preparation, highlights the need for adequate guidance for adults who are yet to seek help for their hearing. The fact that very few people were in the action stage (approximately 3% of the sample) signals that screening alone is unlikely to be enough to improve help-seeking and rehabilitation rates. As expected, people in the later stages of change reported significantly greater hearing disability. The lack of significant relationships between stages-of-change measures and speech-in-noise recognition threshold and self-reported duration of hearing disability highlights the complex interplay between impairment, disability, and behaviors in adults who have failed an online hearing screening and who are yet to seek help.
Screening Newborns' Hearing Now Standard | NIH MedlinePlus the Magazine
... Possible Hearing Problem Your Baby's Hearing and Communicative Development Checklist Communication Considerations —for parents of children with hearing loss Cochlear Implants —surgically implanted hearing ...
Newborn Hearing Screening: An Analysis of Current Practices
ERIC Educational Resources Information Center
Houston, K. Todd; Bradham, Tamala S.; Munoz, Karen F.; Guignard, Gayla Hutsell
2011-01-01
State coordinators of early hearing detection and intervention (EHDI) programs completed a strengths, weaknesses, opportunities, and threats, or SWOT, analysis that consisted of 12 evaluative areas of EHDI programs. For the newborn hearing screening area, a total of 293 items were listed by 49 EHDI coordinators, and themes were identified within…
[Protocols for the health surveillance of fisherman].
Soleo, Leonardo; Cannizzaro, Emanuele; Lovreglio, Piero; Basso, Antonella; D'Errico, Maria Nicolà; Pira, Enrico
2013-01-01
To define protocols for health surveillance of workers in the marine fishing sector for specific occupational risk factors, considering the latest and most advanced scientific knowledge. The specific literature was analyzed to identify the occupational risk factors to which fishermen are exposed. Then, for each risk factor a protocol for the relative health checkups and their time schedule was defined. The risk factors to which fishermen are exposed are essentially noise, vibrations, solar and ultraviolet radiation, climatic agents (heat, cold, wind, rain, damp), chemical agents, shifts, work rate, night work, physical strain, stress, manual handling of loads, upper limb repetitive tasks, incongruous postures. The health protocols stipulate the health screening investigations to be carried out in all workers of a homogeneous group, and in-depth diagnostic investigations to be carried out in symptomatic workers. Complementary health investigations must be focused on a functional exploration of the organs specifically exposed to the risk factor. For hearing impairments due to noise exposure, the medico-legal measures with which the occupational health physician must comply, in cases of occupational disease, are indicated.
Acceptance of internet-based hearing healthcare among adults who fail a hearing screening.
Rothpletz, Ann M; Moore, Ashley N; Preminger, Jill E
2016-09-01
This study measured help-seeking readiness and acceptance of existing internet-based hearing healthcare (IHHC) websites among a group of older adults who failed a hearing screening (Phase 1). It also explored the effects of brief training on participants' acceptance of IHHC (Phase 2). Twenty-seven adults (age 55+) who failed a hearing screening participated. During Phase 1 participants were administered the University of Rhode Island Change Assessment (URICA) and patient technology acceptance model (PTAM) Questionnaire. During Phase 2 participants were randomly assigned to a training or control group. Training group participants attended an instructional class on existing IHHC websites. The control group received no training. The PTAM questionnaire was re-administered to both groups 4-6 weeks following the initial assessment. The majority of participants were either considering or preparing to do something about their hearing loss, and were generally accepting of IHHC websites (Phase 1). The participants who underwent brief IHHC training reported increases in hearing healthcare knowledge and slight improvements in computer self-efficacy (Phase 2). Older adults who fail hearing screenings may be good candidates for IHHC. The incorporation of a simple user-interface and short-term training may optimize the usability of future IHHC programs for this population.
Soli, Sigfrid D; Amano-Kusumoto, Akiko; Clavier, Odile; Wilbur, Jed; Casto, Kristen; Freed, Daniel; Laroche, Chantal; Vaillancourt, Véronique; Giguère, Christian; Dreschler, Wouter A; Rhebergen, Koenraad S
2018-05-01
Validate use of the Extended Speech Intelligibility Index (ESII) for prediction of speech intelligibility in non-stationary real-world noise environments. Define a means of using these predictions for objective occupational hearing screening for hearing-critical public safety and law enforcement jobs. Analyses of predicted and measured speech intelligibility in recordings of real-world noise environments were performed in two studies using speech recognition thresholds (SRTs) and intelligibility measures. ESII analyses of the recordings were used to predict intelligibility. Noise recordings were made in prison environments and at US Army facilities for training ground and airborne forces. Speech materials included full bandwidth sentences and bandpass filtered sentences that simulated radio transmissions. A total of 22 adults with normal hearing (NH) and 15 with mild-moderate hearing impairment (HI) participated in the two studies. Average intelligibility predictions for individual NH and HI subjects were accurate in both studies (r 2 ≥ 0.94). Pooled predictions were slightly less accurate (0.78 ≤ r 2 ≤ 0.92). An individual's SRT and audiogram can accurately predict the likelihood of effective speech communication in noise environments with known ESII characteristics, where essential hearing-critical tasks are performed. These predictions provide an objective means of occupational hearing screening.
Ravi, Rohit; Gunjawate, Dhanshree R; Yerraguntla, Krishna; Rajashekhar, Bellur
2018-01-01
The success of newborn hearing screening programs lies in the timely identification, diagnosis, and management of children with hearing loss accomplished via a multidisciplinary newborn hearing screening (NHS) team. The team is typically comprised of various healthcare professionals who act as decision makers as well as facilitators for different stages in the screening process. Team members' knowledge of, attitudes towards, and practices for early hearing detection and intervention programs are critical for success and prevention of loss to follow up. In this context, it becomes crucial to understand their knowledge of, attitudes towards, and practices for towards newborn hearing screening. A systematic review was conducted on the following databases; PubMed/Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Scopus, Web of Science, Science Direct and Cochrane Library. This search was carried out using various keywords such as practitioners, newborn hearing screening, knowledge, attitudes, and practices in different combinations. The review was conducted based on Preferred Reporting Items for Systematic Reviews and Meta-analyses statement guidelines. A total of 271 hits were obtained of which 20 articles were found suitable for inclusion in the final review. Overall, similar results were found regarding team members' knowledge of NHS programs, regardless of country of origin. Similarly, attitudes toward NHS programs were positive. Team members' experiences with NHS programs varied from country-to-country and across healthcare professionals. Results consistently showed gaps in team members' knowledge suggesting the need for outreach and professional education programs on NHS. NHS teams members from different countries, healthcare systems, and early hearing detection and intervention programs show gaps in critical knowledge warranting outreach and educational programs. Copyright © 2017 Elsevier B.V. All rights reserved.
Newborn hearing screening update for midwifery practice.
Narrigan, D
2000-01-01
Neonatal identification of congenital hearing impairment allows interventions during the first 3 years, the critical period for language and speech development. Two recently developed biophysical testing methods offer simple, accurate, and relatively inexpensive means to identify the one to three in 1,000 healthy newborns with hearing loss. Universal screening for auditory system integrity is advocated, because almost half of all newborns with hearing impairment have no risk factors associated with this impairment. Critics of universal screening cite the high rate of false positive tests (up to 7%), which increases program costs from follow-up and re-testing large numbers of infants to ensure identifying the few affected infants. As of early 2000, 24 states had introduced some type of auditory screening program, and the U.S. Congress had passed legislation with appropriations mandating state-based auditory screening for all newborns. Midwives practicing in states already mandating biophysical screening need to comply with their local requirements; those in other states may voluntarily incorporate new auditory test methods into practice.
Lam, Maggie Yee Yan; Wong, Eddie Chi Ming; Law, Chi Wai; Lee, Helena Hui Ling; McPherson, Bradley
2018-02-01
To facilitate early diagnosis of infants with hearing loss, a universal newborn hearing screening program (UNHS) has been implemented in Hong Kong's public hospitals for over a decade. However, there have been no known studies investigating parent attitudes to, and satisfaction with, UNHS since its launch in Hong Kong. The present study aimed to investigate knowledge of UNHS as well as infant hearing development, and attitudes and satisfaction with UNHS, in Hong Kong mothers with newborns. The study was designed to help evaluate and improve an established UNHS public hospital program, based on the perspectives of service users. A researcher-developed questionnaire was administered to 102 mothers whose newborn had received UNHS in the postnatal wards of a large public hospital in Hong Kong. The questionnaire considered parental knowledge of UNHS and infant hearing development, attitudes and satisfaction toward public hospital UNHS. In the knowledge dimension, parents' preferred time and location for pre-test information delivery, interpretation of screening results, and knowledge of hearing developmental milestones were surveyed. In addition, maternal attitudes to and satisfaction with UNHS screening services, the potential impact of UNHS on parent emotions and parent-baby bonding, attitudes toward informed consent, and willingness to comply with diagnostic assessment referral were also be surveyed. Mean participant scores on knowledge of infant hearing development were relatively low (M = 2.59/6.0, SD = 0.90). Many mothers also underestimated the potential ongoing risks of hearing impairment in babies. Around 80% of mothers thought an infant could not have hearing impairment after passing the screening. In addition, one-third of mothers thought a baby could not later develop hearing impairment in infancy or childhood. In terms of attitudes and satisfaction, participants gave somewhat negative ratings for questions regarding receiving sufficient information about the screening (M = 2.90/5.0, SD = 1.27), screening procedure (M = 2.20/5.0, SD = 1.08), and sufficiency of information about results (M = 2.87/5.0, SD = 1.14). Nonetheless, participants gave positive ratings concerning whether screening could lead to early diagnosis (M = 4.61/5.0, SD = 0.57) and over 95% of mothers supported UNHS despite potential for false positive results. Mothers reported a high willingness to bring their baby to follow-up assessments if required (M = 4.53/5.0, SD = 0.56). Participants gave positive ratings for their level of satisfaction with the time and location of first UNHS information provision (M = 4.34/5.0, SD = 0.80) and the way permission was asked for screening the baby (M = 4.04/5.0, SD = 0.97) but alternative procedures were also recommended. Most recommendations focused on providing more information about the test and a more detailed explanation of screening results. The survey results highlighted the need to provide more information to parents about infant hearing development to support home monitoring for signs of hearing loss after UNHS, as well as more detailed explanation and information regarding hearing screening and the implications of results to parents. Regardless of location, surveys of this type may provide valuable support for UNHS program quality assurance. Copyright © 2017. Published by Elsevier B.V.
... Hearing Loss Homepage Basics Noise-Induced Hearing Loss Genetics of Hearing Loss Screening & Diagnosis Types of Hearing Loss About Sound Treatment & Intervention Services Learning Language Bacterial Meningitis Studies Data & Statistics EHDI Annual Data 2016 2015 2014 2013 ...
... Hearing Loss Homepage Basics Noise-Induced Hearing Loss Genetics of Hearing Loss Screening & Diagnosis Types of Hearing Loss About Sound Treatment & Intervention Services Learning Language Bacterial Meningitis Studies Data & Statistics EHDI Annual Data 2016 2015 2014 2013 ...
Should patients with asymmetrical noise-induced hearing loss be screened for vestibular schwannomas?
Baker, R; Stevens-King, A; Bhat, N; Leong, P
2003-08-01
The Peterborough ENT department receives many referrals for MoD personnel who have suffered hearing loss from occupational noise exposure. Those patients with asymmetrical sensorineural hearing loss are routinely screened for vestibular schwannomas by MRI scanning. Scan reports from the past 5 years have been reviewed and out of 152 scans, four revealed vestibular schwannomas giving a pick-up rate of 2.5%, which compares favourably with other published pick-up rates. Review of the audiograms in these cases suggests that they can be misleading in this context. The conclusion is that patients with noise-induced asymmetrical hearing loss should be screened for acoustic neuromas.
Hearing loss screening tool (COBRA score) for newborns in primary care setting
Poonual, Watcharapol; Navacharoen, Niramon; Kangsanarak, Jaran; Namwongprom, Sirianong
2017-01-01
Purpose To develop and evaluate a simple screening tool to assess hearing loss in newborns. A derived score was compared with the standard clinical practice tool. Methods This cohort study was designed to screen the hearing of newborns using transiently evoked otoacoustic emission and auditory brain stem response, and to determine the risk factors associated with hearing loss of newborns in 3 tertiary hospitals in Northern Thailand. Data were prospectively collected from November 1, 2010 to May 31, 2012. To develop the risk score, clinical-risk indicators were measured by Poisson risk regression. The regression coefficients were transformed into item scores dividing each regression-coefficient with the smallest coefficient in the model, rounding the number to its nearest integer, and adding up to a total score. Results Five clinical risk factors (Craniofacial anomaly, Ototoxicity, Birth weight, family history [Relative] of congenital sensorineural hearing loss, and Apgar score) were included in our COBRA score. The screening tool detected, by area under the receiver operating characteristic curve, more than 80% of existing hearing loss. The positive-likelihood ratio of hearing loss in patients with scores of 4, 6, and 8 were 25.21 (95% confidence interval [CI], 14.69–43.26), 58.52 (95% CI, 36.26–94.44), and 51.56 (95% CI, 33.74–78.82), respectively. This result was similar to the standard tool (The Joint Committee on Infant Hearing) of 26.72 (95% CI, 20.59–34.66). Conclusion A simple screening tool of five predictors provides good prediction indices for newborn hearing loss, which may motivate parents to bring children for further appropriate testing and investigations. PMID:29234358
ERIC Educational Resources Information Center
Patterson, Karen; Dancer, Jess
1987-01-01
Describes program in which American Speech-Language-Hearing Association certified audiologists train protocol providers to assist older hearing-aid users in adjusting to using hearing aids on a daily basis. Training emphasizes empathy, effective communication skills, knowledge of the interaction of aging and hearing loss, phases outlined in…
Risk factors for sensorineural hearing loss in children.
Núñez-Batalla, Faustino; Trinidad-Ramos, Germán; Sequí-Canet, José Miguel; Alzina De Aguilar, Valentín; Jáudenes-Casaubón, Carmen
2012-01-01
In the last decade, tremendous progress has been made very rapidly in the development of Early Hearing Detection and Intervention (EHDI) systems as a major public health initiative. The percentage of infants screened annually in Spain has increased significantly since the EHDI systems have expanded to all autonomic regions. Historically, high risk indicators have been used for the identification of infants who should receive audiological evaluation but who live in geographic locations where universal hearing screening is not yet available, to help identify infants who pass neonatal screening but are at risk of developing delayed-onset hearing loss and to identify infants who may have passed neonatal screening but have mild forms of permanent hearing loss. In this review, the standard risk factors for hearing loss are analysed and the risk factors known to be associated with late onset or progressive hearing loss are identified. The recommendation for infants with a risk factor that may be considered as low risk is to perform at least one audiology assessment by 24-30 months. In contrast, for an infant with risk factors known to be associated with late onset or progressive hearing loss (such as cytomegalovirus infection or family history), early and more frequent assessment is appropriate. All infants should have an objective standardised screening of global development with a validated assessment tool at 9, 18 and 24-30 months of age or at any time if the health care professional or the family is concerned. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Hearing loss among high-risk newborns admitted to a tertiary Neonatal Intensive Care Unit.
Khairy, May Ahmed; Abuelhamed, Walaa Alsharany; Ahmed, Radwa Sayed; El Fouly, Hedayet El Sayed; Elhawary, Ismail Mohamed
2018-07-01
The aim of this work is to identify the most significant risk factors for hearing impairment in high risk neonates hospitalized at our Neonatal Intensive Care Unit (NICU) and to assess the sensitivity of hearing screening tests. This study involved 260 neonates admitted to a tertiary NICU; they were classified into two groups; 150 preterm and 110 full terms with risk factors for hearing loss. The hearing screening tests performed were transient evoked otoacoustic emissions (TEOAEs) and the automated auditory brainstem response (AABR). Forty-eight preterm neonates (32%) and 30 full term neonates (27.3%) had pathological AABR. In preterm group, mechanical ventilation more than five days, sepsis, usage of aminoglycosides, loop diuretics, vancomycin alone or in combination with aminoglycosides and prolonged duration of admission were considered risk factors of hearing affection whereas in full term group mechanical ventilation more than five days was the risk factor of hearing affection (p<.05). The prevalence of hearing loss is highest among high risk neonates and TEOAE and AABR were found to be reliable screening tools. Use of ototoxic drugs and mechanical ventilation for more than five days were significant risk factors for hearing loss in our study population.
Genetics Evaluation Guidelines for the Etiologic Diagnosis of Congenital Hearing Loss
2002-01-01
The advent of hearing screening in newborns in many states has led to an increase in the use of genetic testing and related genetic services in the follow-up of infants with hearing loss. A significant proportion of those with congenital hearing loss have genetic etiologies underlying their hearing loss. To ensure that those identified with congenital hearing loss receive the genetic services appropriate to their conditions, the Maternal and Child Health Bureau of the Health Resources and Services Administration funded the American College of Medical Genetics to convene an expert panel to develop guidelines for the genetic evaluation of congential hearing loss. After a brief overview of the current knowledge of hearing loss, newborn screening, and newborn hearing screening, we provide an overview of genetic services and a guideline that describes how best to ensure that patients receive appropriate genetic services. The significant contribution of genetic factors to these conditions combined with the rapid evolution of knowledge about the genetics of these conditions overlaid with the inherently multidisciplinary nature of genetic services provides an example of a condition for which a well-integrated multidisciplinary approach to care is clearly needed. PMID:12180152
Hearing conservation and noise management practices in professional orchestras.
O'Brien, Ian; Driscoll, Tim; Ackermann, Bronwen
2012-01-01
Hearing conservation and noise exposure management for professional orchestras is a difficult issue resistant to standard control measures as used in other industries with excessive noise problems. Although there has been a great deal of research into this area in terms of the audiological status of musicians and their exposure to noise, there are relatively few industry-specific strategies that can be adopted by an orchestra looking to address these issues. Australia does not have a uniform approach to hearing conservation management in its orchestras; however, each orchestra actively grapples with the challenges of balancing legal, practical, and artistic concerns. This study systematically investigated hearing conservation practices, noise exposure management, and audiological screening protocols in eight professional orchestras. The research involved personal interviews with staff at each orchestra, including inspection of venues and facilities. While all these orchestras were aware of the risks and were actively taking significant steps to reduce noise exposure, a range of approaches, with varying degrees of effectiveness and understanding of the issue, were found across the sector. There was limited evidence of educational programs for either the musicians at risk of excessive noise exposure or the staff responsible for devising and implementing control measures. In addition, the reported use of adequate personal hearing protection by musicians was poor. As Australia has recently introduced a national approach to workplace health and safety, a similar approach to noise and audiological management across the country's orchestral sector is proposed, drawn from existing research and practice. This will enable both consistent procedures and meaningful dialogue between the orchestras on the topics of hearing conservation, audiological monitoring, and educational practices.
Diagnostic utility of the acoustic reflex in predicting hearing in paediatric populations.
Pérez-Villa, Yolanda E; Mena-Ramírez, María E; Aguirre, Laura E Chamlati; Mora-Magaña, Ignacio; Gutiérrez-Farfán, Ileana S
2014-01-01
The sensitivity of prediction of acoustic reflex, in determining the level of hearing loss, is especially useful in paediatric populations. It is based on the difference between the pure tone stapedius reflex threshold and contralateral white noise. The white noise threshold was 60 dB and that of pure tone was 80 dB. Our objective was to determine the diagnostic sensitivity of the prediction of the acoustic reflex. We studied children aged <10 years, from October 2011 to May 2012, by measuring the acoustic reflex with white noise and pure tone. We used contrast tests, with X2 and student t-test. Concordance was measured with Kappa. Results were considered significant at P≤.05. Our protocol was approved by Institutional Ethics Committee. Informed consent was obtained from the parents in all cases. Prediction of normal hearing was 0.84 for the right ear and 0.78 in left ear, while for hearing loss of an unspecified grade, it was 0.98 for the right ear and 0.96 in the left ear. Kappa value was 0.7 to 0.6 for the right ear and left ear. The acoustic reflex is of little diagnostic utility in predicting the degree of hearing loss, but it predicts more than 80% of normal hearing. The clinical utility of the reflex is indisputable, as it is an objective method, simple and rapid to use, that can be performed from birth and whose results are independent of the cooperation and willingness of the subject. It is proposed as an obligatory part of hearing screening. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Association between language and hearing disorders – risk identification
Samelli, Alessandra Giannella; Rondon-Melo, Silmara; Rabelo, Camila Maia; Molini-Avejonas, Daniela Regina
2017-01-01
OBJECTIVE: To identify children at risk for hearing and/or language disorders and to investigate the association between these risks by conducting pre-validated hearing and language screenings. METHODS: The study was conducted during a polio vaccination campaign in August of 2013 in basic health units in western São Paulo. Parents of children between 2 and 5 years of age were asked to complete two screening tools: a hearing questionnaire (regarding hearing development) and a language production and comprehension scale (including the major language development milestones). The screening tools were administered by different researchers. We compared the risk of having language disorders among children at risk for hearing loss versus children not at risk, as well as the attributable risk and odds ratios. Chi-squared tests and logistic regression analyses were used. RESULTS: The study included 479 children with a mean age of three and one-half years, of whom 26.9% were identified as at risk for deficits in language production, 8.6% were at risk for deficits in language comprehension and 14% were at risk for hearing disorders. The children at risk for hearing disorders were twice as likely as those not at risk to exhibit language production and comprehension deficits. CONCLUSION: The results of this study highlight the importance of establishing and adopting low-cost procedures such as screenings to identify children at risk of developing language and/or hearing disorders in early childhood. PMID:28492720
Gussenhoven, Arjenne H M; Singh, Amika S; Goverts, S Theo; van Til, Marten; Anema, Johannes R; Kramer, Sophia E
2015-08-01
A multidisciplinary vocational rehabilitation programme, the Vocational Enablement Protocol (VEP) was developed to address the specific needs of employees with hearing difficulties. In the current study we evaluated the process of implementing the VEP in audiologic care among employees with hearing impairment. In conjunction with a randomized controlled trial, we collected and analysed data on seven process parameters: recruitment, reach, fidelity, dose delivered, dose received and implemented, satisfaction, and perceived benefit. Sixty-six employees with hearing impairment participated in the VEP. The multidisciplinary team providing the VEP comprised six professionals. The professionals performed the VEP according to the protocol. Of the recommendations delivered by the professionals, 31% were perceived as implemented by the employees. Compliance rate was highest for hearing-aid uptake (51%). Both employees and professionals were highly satisfied with the VEP. Participants rated good perceived benefit from it. Our results indicate that the VEP could be a useful treatment for employees with hearing difficulties from a process evaluation perspective. Implementation research in the audiological setting should be encouraged in order to further provide insight into parameters facilitating or hindering successful implementation of an intervention and to improve its quality and efficacy.
Wong, Lye-Yeng; Espinoza, Francisca; Alvarez, Karen Mojica; Molter, Dave; Saunders, James E
2017-05-01
Objective (1) Determine the incidence and risk factors for congenital hearing loss. (2) Perform cost analysis of screening programs. Study Design Proportionally distributed cross-sectional survey. Setting Jinotega, Nicaragua. Subjects and Methods Otoacoustic emissions (OAEs) were used to screen 640 infants <6 months of age from neonatal intensive care unit, institutional, and home birth settings. Data on 15 risk factors were analyzed. Cost of 4 implementation strategies was studied: universal screening, screening at the regional health center (RHC), targeted screening, and screening at the RHC plus targeted screening. Cost-effectiveness analysis over 10 years was based on disability-adjusted life year estimates, with the World Health Organization standard of cost-effectiveness ratio (CER) / gross domestic product (GDP) <3, with GDP set at $4884.15. Results Thirty-eight infants failed the initial OAE (5.94%). In terms of births, 325 (50.8%) were in the RHC, 69 (10.8%) in the neonatal intensive care unit, and 29 (4.5%) at home. Family history and birth defect were significant in univariate analysis; birth defect was significant in multivariate analysis. Cost-effectiveness analysis demonstrated that OAE screening is cost-effective without treatment (CER/GDP = 0.06-2.00) and with treatment (CER/GDP = 0.58-2.52). Conclusions Our rate of OAE failures was comparable to those of developed countries and lower than hearing loss rates noted among Nicaraguan schoolchildren, suggesting acquired or progressive etiology in the latter. Birth defects and familial hearing loss correlated with OAE failure. OAE screening of infants is feasible and cost-effective in rural Nicaragua, although highly influenced by estimated hearing loss severity in identified infants and the high travel costs incurred in a targeted screening strategy.
Utility of genetic testing for the detection of late-onset hearing loss in neonates.
Lim, B Gail; Clark, Reese H; Kelleher, Amy S; Lin, Zhili; Spitzer, Alan R
2013-12-01
The purpose of this study was to demonstrate the utility of molecular testing in the detection of potentially important causes of delayed hearing loss missed by current audiometric screening at birth. We enrolled infants who had received a newborn audiometric hearing screen and a filter paper blood collection for state newborn screening. A central laboratory ran the SoundGene® panel. Of 3,681 infants studied, 35 (0.95%) had a positive SoundGene panel, 16 had mitochondrial mutations, 9 had Pendred mutations, 5 were cytomegalovirus (CMV) DNA positive, 2 had connexin mutations, and 3 had a combination of different mutations. Infants with an abnormal SoundGene panel were at increased risk for hearing loss compared to neonates without mutations. Three (8.6%) of the 35 subjects had persistent hearing loss compared to 5 (0.21%) of 2,398 subjects with no report of mutation (p < .01). Of 3,681 infants studied, 8 (0.22%) had persistent hearing loss: 5 (62.5%) had abnormal newborn audiometric screens, 2 (25%) had an abnormal SoundGene panel (1 was CMV positive, 1 had a mitochondrial mutation), and 1 (12.5%) had no identifiable risk factors. A positive SoundGene panel identifies infants who are not identified by audiometric testing and may be at risk for hearing loss.
Item Response Theory Applied to Factors Affecting the Patient Journey Towards Hearing Rehabilitation
Chenault, Michelene; Berger, Martijn; Kremer, Bernd; Anteunis, Lucien
2016-01-01
To develop a tool for use in hearing screening and to evaluate the patient journey towards hearing rehabilitation, responses to the hearing aid rehabilitation questionnaire scales aid stigma, pressure, and aid unwanted addressing respectively hearing aid stigma, experienced pressure from others; perceived hearing aid benefit were evaluated with item response theory. The sample was comprised of 212 persons aged 55 years or more; 63 were hearing aid users, 64 with and 85 persons without hearing impairment according to guidelines for hearing aid reimbursement in the Netherlands. Bias was investigated relative to hearing aid use and hearing impairment within the differential test functioning framework. Items compromising model fit or demonstrating differential item functioning were dropped. The aid stigma scale was reduced from 6 to 4, the pressure scale from 7 to 4, and the aid unwanted scale from 5 to 4 items. This procedure resulted in bias-free scales ready for screening purposes and application to further understand the help-seeking process of the hearing impaired. PMID:28028428
Acclimatization in first-time hearing aid users using three different fitting protocols.
Reber, Monika Bertges; Kompis, Martin
2005-12-01
To study auditory acclimatization and outcome in first time hearing aid users fitted with state of the art hearing aids as a function of different hearing aid fitting protocols. Twenty-eight adult subjects participated in the study. Each subject was assigned to one of three study groups (named audiologist driven, AD; patient driven, PD; set-to-target, STT according to the fitting protocol used) and fitted with digital hearing aids (Bernafon Symbio). Speech recognition scores were measured in aided and unaided conditions over a 6-month period. Five subjects (three from the PD-group, two from the STT group) decided to withdraw from the study during the 6-month-study period, leaving a total of 23 complete data sets for analysis. Aided speech understanding increased significantly over this time period in all three groups. However, average hearing aid insertion gain changes were small over the same period. There were no statistically significant differences in aided or unaided speech recognition scores between the three groups after 2 weeks or after 6 months. On average, twice as many fine tunings of the hearing aids were requested by the patients in the AD and the STT group than in the PD group and subjects in the AD and STT group used their hearing aids approximately twice as much as subjects in the PD group. The substantial increase in speech intelligibility without significant changes of the insertion gain of the hearing aids over a 6-month period in all three groups suggests a significant acclimatization effect. Although the speech recognition with hearing aids did not differ significantly among the three study groups after 6 months, the lower average wearing time and the higher number of withdrawals from the study in the PD group suggest that the patients' needs are not adequately met. In terms of aided speech recognition scores and hearing aid wearing time the STT group and the AD group were very similar. However, comments of the patients and the higher rate of withdrawals in the STT group suggest an over-all advantage for the AD fitting protocol.
ERIC Educational Resources Information Center
De Raeve, Leo; Lichtert, Guido
2012-01-01
The purpose of this study is to show the changing trends within the population of children who are deaf and hard of hearing in Belgium over the last 12 years. The combination of Universal Newborn Hearing Screening programs, early intervention, and cochlear implants have tremendously influenced the education and support of children who are deaf or…
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 2 2014-01-01 2014-01-01 false Hearings. 785.12 Section 785.12... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.12 Hearings. (a) Scheduling. Upon receipt of a valid request for a hearing, the ALJ shall, by agreement with all...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Hearings. 785.12 Section 785.12... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.12 Hearings. (a) Scheduling. Upon receipt of a valid request for a hearing, the ALJ shall, by agreement with all...
Economic evaluation of long-term impacts of universal newborn hearing screening.
Chiou, Shu-Ti; Lung, Hou-Ling; Chen, Li-Sheng; Yen, Amy Ming-Fang; Fann, Jean Ching-Yuan; Chiu, Sherry Yueh-Hsia; Chen, Hsiu-Hsi
2017-01-01
Little is known about the long-term efficacious and economic impacts of universal newborn hearing screening (UNHS). An analytical Markov decision model was framed with two screening strategies: UNHS with transient evoked otoacoustic emission (TEOAE) test and automatic acoustic brainstem response (aABR) test against no screening. By estimating intervention and long-term costs on treatment and productivity losses and the utility of life years determined by the status of hearing loss, we computed base-case estimates of the incremental cost-utility ratios (ICURs). The scattered plot of ICUR and acceptability curve was used to assess the economic results of aABR versus TEOAE or both versus no screening. A hypothetical cohort of 200,000 Taiwanese newborns. TEOAE and aABR dominated over no screening strategy (ICUR = $-4800.89 and $-4111.23, indicating less cost and more utility). Given $20,000 of willingness to pay (WTP), the probability of being cost-effective of aABR against TEOAE was up to 90%. UNHS for hearing loss with aABR is the most economic option and supported by economically evidence-based evaluation from societal perspective.
Li, Pei-Chun; Chen, Wei-I; Huang, Chih-Ming; Liu, Ching-Ju; Chang, Hsiu-wen; Lin, Hung-Ching
2016-01-01
Objectives To determine whether newborn hearing screening in a well-baby nursery (WBN) and neonatal intensive care unit (NICU) nursery: 1) meet three targeted, screening, referral, and diagnostic follow-up rates; 2) compare the average age of diagnosis for infants admitted to the WIN and NICU; and 3) determine prevalence of hearing loss in neonatal population; and 4) try to find a practical newborn hearing screening time algorithm to reduce refer rate in NICU Materials and Methods It examined 15,624 newborns in the WBN (13,676) and NICU (1948) screened for congenital HL using AABR. The variables analyzed in it were the screening rate, referral rate, follow-up rate, diagnostic rate and diagnostic age, prevalence rate, degrees of congenital bilateral HL. The study was approved by the hospital’s institutional review board (13MMHISO23). Results The screening rates were 99.8% and 99.6% in the WBN and NICU groups, respectively, without significant difference. The referral rates were 0.7% and 2.8% in the WBN and NICU groups, with significant difference. Furthermore, the diagnostic follow-up rates were 76.7% and 89.1% in the WBN and NICU groups, without significant difference. The average initial diagnostic ages were 1.9 months and 3.8 months in the WBN and NICU groups, with significant difference. The prevalence of congenital bilateral hearing loss were 0.27% and 1.6% in the WBN and NICU groups, with significant difference. Conclusion The screening, referral and follow-up rate in the WBN and NICU groups were equivalent to the quality indicators. For NICU group, screening and diagnostic follow up were performed later than those in WBN group; however the lower referral rate in our NICU group was successfully achieved in this study and can be applied clinically. The prevalence of congenital bilateral hearing loss was higher in the NICU group than in the WBN group. PMID:27023324
Li, Pei-Chun; Chen, Wei-I; Huang, Chih-Ming; Liu, Ching-Ju; Chang, Hsiu-wen; Lin, Hung-Ching
2016-01-01
To determine whether newborn hearing screening in a well-baby nursery (WBN) and neonatal intensive care unit (NICU) nursery: 1) meet three targeted, screening, referral, and diagnostic follow-up rates; 2) compare the average age of diagnosis for infants admitted to the WIN and NICU; and 3) determine prevalence of hearing loss in neonatal population; and 4) try to find a practical newborn hearing screening time algorithm to reduce refer rate in NICU. It examined 15,624 newborns in the WBN (13,676) and NICU (1948) screened for congenital HL using AABR. The variables analyzed in it were the screening rate, referral rate, follow-up rate, diagnostic rate and diagnostic age, prevalence rate, degrees of congenital bilateral HL. The study was approved by the hospital's institutional review board (13MMHISO23). The screening rates were 99.8% and 99.6% in the WBN and NICU groups, respectively, without significant difference. The referral rates were 0.7% and 2.8% in the WBN and NICU groups, with significant difference. Furthermore, the diagnostic follow-up rates were 76.7% and 89.1% in the WBN and NICU groups, without significant difference. The average initial diagnostic ages were 1.9 months and 3.8 months in the WBN and NICU groups, with significant difference. The prevalence of congenital bilateral hearing loss were 0.27% and 1.6% in the WBN and NICU groups, with significant difference. The screening, referral and follow-up rate in the WBN and NICU groups were equivalent to the quality indicators. For NICU group, screening and diagnostic follow up were performed later than those in WBN group; however the lower referral rate in our NICU group was successfully achieved in this study and can be applied clinically. The prevalence of congenital bilateral hearing loss was higher in the NICU group than in the WBN group.
Two-Way Radio Modem Data Transfer for Newborn Hearing Screening Devices.
Matulat, Peter; Lepper, Ingo; Böttcher, Peter; Parfitt, Ross; Oswald, Hans; Am Zehnhoff-Dinnesen, Antoinette; Deuster, Dirk
2017-01-01
The success of a newborn hearing screening program depends on successful tracking and follow-up to ensure that children who have had positive screening results in the first few days of life receive appropriate and timely diagnostic and intervention services. The easy availability, through a suitable infrastructure, of the data necessary for the tracking, diagnosis, and care of children concerned is a major key to enhancing the quality and efficiency of newborn hearing screening programs. Two systems for the automated two-way transmission of newborn hearing screening and configuration data, based on mobile communication technology, for the screening devices MADSEN AccuScreen ® and Natus Echo-Screen ® were developed and tested in a field study. Radio modem connections were compared with conventional analogue modem transmissions from Natus Echo-Screen devices for duration, transmission rate, number of lost connections, and frequency of use. The average session duration was significantly lower with the MADSEN AccuScreen (12 s) and Natus Echo-Screen both with radio modem (15 s) than the Natus Echo-Screen with analogue modem (108 s). The transmission rate was significantly higher (898 and 1,758 vs. 181 bytes/s) for the devices with radio modems. Both radio modem devices had significantly lower rates of broken connections after initial connection (2.1 and 0.9 vs. 5.5%). An increase in the frequency of data transmission from the clinics with mobile radio devices was found. The use of mobile communication technology in newborn hearing screening devices offers improvements in the average session duration, transmission rate, and reliability of the connection over analogue solutions. We observed a behavioral change in clinical staff using the new technology: the data exchange with the tracking center is more often used. The requirements for on-site support were reduced. These savings outweigh the small increase in costs for the Internet service provider.
The University of Western Ontario Pediatric Audiological Monitoring Protocol (UWO PedAMP)
Moodie, Sheila T.; Malandrino, April C.; Richert, Frances M.; Clench, Debbie A.; Scollie, Susan D.
2011-01-01
This study proposed and evaluated a guideline for outcome evaluation for infants and children with hearing loss who wear hearing aids. The University of Western Ontario Pediatric Audiological Monitoring Protocol (UWO PedAMP) was developed following a critical review of pediatric outcome evaluation tools and was systematically examined by the Network of Pediatric Audiologists of Canada. It consists of tools to gather clinical process outcomes as well as functional caregiver reports. The UWO PedAMP was administered to a clinical population of infants and children with hearing aids. Sixty-eight children were administered the functional outcome evaluation tools (i.e., caregiver reports) a total of 133 times. Clinical process outcomes of hearing aid verification (e.g., real-ear-to-coupler difference) revealed typical aided audibility (e.g., Speech Intelligibility Index). Results for the LittlEARS® questionnaire revealed that typically developing children with hearing loss who wear hearing aids are meeting auditory development milestones. Children with mild to moderate comorbidities displayed typical auditory development during the 1st year of life after which development began to decline. Children with complex factors related to hearing aid use had lower scores on the LittlEARS, but auditory development was in parallel to norms. Parents’ Evaluation of Aural/Oral Performance (PEACH) results indicated no age effect on scoring for children above 2 years of age; however, the effect of degree of hearing loss was significant. This work provides clinicians with a systematic, evidence-based outcome evaluation protocol to implement as part of a complete pediatric hearing aid fitting. PMID:22194316
Schlund, M W
2000-10-01
Bedside hearing screenings are routinely conducted by speech and language pathologists for brain injury survivors during rehabilitation. Cognitive deficits resulting from brain injury, however, may interfere with obtaining estimates of auditory thresholds. Poor comprehension or attention deficits often compromise patient abilities to follow procedural instructions. This article describes the effects of jointly applying behavioral methods and psychophysical methods to improve two severely brain-injured survivors' attending and reporting on auditory test stimuli presentation. Treatment consisted of stimulus control training that involved differentially reinforcing responding in the presence and absence of an auditory test tone. Subsequent hearing screenings were conducted with novel auditory test tones and a common titration procedure. Results showed that prior stimulus control training improved attending and reporting such that hearing screenings were conducted and estimates of auditory thresholds were obtained.
A Targeted Approach for Congenital Cytomegalovirus Screening Within Newborn Hearing Screening
McCollister, Faye P.; Sabo, Diane L.; Shoup, Angela G.; Owen, Kris E.; Woodruff, Julie L.; Cox, Edith; Mohamed, Lisa S.; Choo, Daniel I.; Boppana, Suresh B.
2017-01-01
BACKGROUND AND OBJECTIVE: Congenital cytomegalovirus (cCMV) infection remains a leading cause of childhood hearing loss. Currently universal CMV screening at birth does not exist in the United States. An alternative approach could be testing infants who do not pass their newborn hearing screening (NHS) for cCMV. This study was undertaken to evaluate whether a targeted approach will identify infants with CMV-related sensorineural hearing loss (SNHL). METHODS: Infants born at 7 US medical centers received NHS and were also screened for cCMV while in the newborn nursery. Infants who tested positive for CMV received further diagnostic audiologic evaluations to identify or confirm hearing loss. RESULTS: Between 2007 and 2012, 99 945 newborns were screened for both hearing impairment and cCMV. Overall, 7.0% of CMV-positive infants did not pass NHS compared with 0.9% of CMV-negative infants (P < .0001). Among the cCMV infants who failed NHS, diagnostic testing confirmed that 65% had SNHL. In addition, 3.6% of CMV-infected infants who passed their NHS had SNHL confirmed by further evaluation during early infancy. NHS in this cohort identified 57% of all CMV-related SNHL that occurred in the neonatal period. CONCLUSIONS: A targeted CMV approach that tests newborns who fail their NHS identified the majority of infants with CMV-related SNHL at birth. However, 43% of the infants with CMV-related SNHL in the neonatal period and cCMV infants who are at risk for late onset SNHL were not identified by NHS. PMID:28049114
ERIC Educational Resources Information Center
Wilson, Richard H.; McArdle, Rachel A.; Smith, Sherri L.
2007-01-01
Purpose: The purpose of this study was to examine in listeners with normal hearing and listeners with sensorineural hearing loss the within- and between-group differences obtained with 4 commonly available speech-in-noise protocols. Method: Recognition performances by 24 listeners with normal hearing and 72 listeners with sensorineural hearing…
Improved Newborn Hearing Screening Follow-up Results in More Infants Identified
Alam, Suhana; Gaffney, Marcus; Eichwald, John
2015-01-01
Longitudinal research suggests that efforts at the national, state, and local levels are leading to improved follow-up and data reporting. Data now support the assumption that the number of deaf or hard-of-hearing infants identified through newborn hearing screening increases with a reduction in the number of infants lost to follow-up. Documenting the receipt of services has made a noticeable impact on reducing lost to follow-up rates and early identification of infants with hearing loss; however, continued improvement and monitoring of services are still needed. PMID:23803975
Improved newborn hearing screening follow-up results in more infants identified.
Alam, Suhana; Gaffney, Marcus; Eichwald, John
2014-01-01
Longitudinal research suggests that efforts at the national, state, and local levels are leading to improved follow-up and data reporting. Data now support the assumption that the number of deaf or hard-of-hearing infants identified through newborn hearing screening increases with a reduction in the number of infants lost to follow-up. Documenting the receipt of services has made a noticeable impact on reducing lost to follow-up rates and early identification of infants with hearing loss; however, continued improvement and monitoring of services are still needed.
Validated Smartphone-Based Apps for Ear and Hearing Assessments: A Review
Pallawela, Danuk
2016-01-01
Background An estimated 360 million people have a disabling hearing impairment globally, the vast majority of whom live in low- and middle-income countries (LMICs). Early identification through screening is important to negate the negative effects of untreated hearing impairment. Substantial barriers exist in screening for hearing impairment in LMICs, such as the requirement for skilled hearing health care professionals and prohibitively expensive specialist equipment to measure hearing. These challenges may be overcome through utilization of increasingly available smartphone app technologies for ear and hearing assessments that are easy to use by unskilled professionals. Objective Our objective was to identify and compare available apps for ear and hearing assessments and consider the incorporation of such apps into hearing screening programs Methods In July 2015, the commercial app stores Google Play and Apple App Store were searched to identify apps for ear and hearing assessments. Thereafter, six databases (EMBASE, MEDLINE, Global Health, Web of Science, CINAHL, and mHealth Evidence) were searched to assess which of the apps identified in the commercial review had been validated against gold standard measures. A comparison was made between validated apps. Results App store search queries returned 30 apps that could be used for ear and hearing assessments, the majority of which are for performing audiometry. The literature search identified 11 eligible validity studies that examined 6 different apps. uHear, an app for self-administered audiometry, was validated in the highest number of peer reviewed studies against gold standard pure tone audiometry (n=5). However, the accuracy of uHear varied across these studies. Conclusions Very few of the available apps have been validated in peer-reviewed studies. Of the apps that have been validated, further independent research is required to fully understand their accuracy at detecting ear and hearing conditions. PMID:28582261
Joo, Byung-Euk; Park, Sang-Ku; Cho, Kyung-Rae; Kong, Doo-Sik; Seo, Dae-Won; Park, Kwan
2016-11-01
OBJECTIVE The aim of this study was to define a new protocol for intraoperative monitoring (IOM) of brainstem auditory evoked potentials (BAEPs) during microvascular decompression (MVD) surgery to treat hemifacial spasm (HFS) and to evaluate the usefulness of this new protocol to prevent hearing impairment. METHODS To define the optimal stimulation rate, estimate the number of trials to be averaged, and identify useful warning criteria in IOM of BAEPs, the authors performed a preliminary study of 13 patients with HFS in 2010. They increased the stimulation rate from 10.1 Hz/sec to 100.1 Hz/sec by 10-Hz increments, and they elevated the average time from 100 times to 1000 times by 100-unit increments at a fixed stimulus rate of 43.9 Hz. After defining the optimal stimulation rate and the number of trials that needed to be averaged for IOM of BAEPs, they also identified the useful warning criteria for this protocol for MVD surgery. From January to December 2013, 254 patients with HFS underwent MVD surgery following the new IOM of BAEPs protocol. Pure-tone audiometry and speech discrimination scoring were performed before surgery and 1 week after surgery. To evaluate the usefulness of the new protocol, the authors compared the incidence of postoperative hearing impairment with the results from the group that underwent MVD surgery prior to the new protocol. RESULTS Through a preliminary study, the authors confirmed that it was possible to obtain a reliable wave when using a stimulation rate of 43.9 Hz/sec and averaging 400 trials. Only a Wave V amplitude loss > 50% was useful as a warning criterion when using the new protocol. A reliable BAEP could be obtained in approximately 9.1 seconds. When the new protocol was used, 2 patients (0.8%) showed no recovery of Wave V amplitude loss > 50%, and only 1 of those 2 patients (0.39%) ultimately had postoperative hearing impairment. When compared with the outcomes in the pre-protocol group, hearing impairment incidence decreased significantly among patients who underwent surgery with the new protocol (0.39% vs 4.02%, p = 0.002). There were no significant differences between the 2 surgery groups regarding other complications, including facial palsy, sixth cranial nerve palsy, and vocal cord palsy. CONCLUSIONS There was a significant decrease in postoperative hearing impairment after MVD for HFS when the new protocol for IOM of BAEPs was used. Real-time IOM of BAEPs, which can obtain a reliable BAEP in less than 10 seconds, is a successful new procedure for preventing hearing impairment during MVD surgery for HFS.
Introduction to the AJA research forum on aging and hearing: mechanisms and effects.
Paglialonga, Alessia; Grandori, Ferdinando
2013-12-01
PURPOSE This Research Forum, "Aging and Hearing: Mechanisms and Effects," highlights 6 contributions presented at the 2nd International Conference on Adult Hearing Screening (AHS 2012), held in Cernobbio (Lake Como, Italy) in June 2012. Overall, the articles in this Research Forum give insight into the causes, mechanisms, and consequences of auditory dysfunctions in adults, with particular focus on their implications for screening, assessment, and intervention.
Mason, Craig A; Gaffney, Marcus; Green, Denise R; Grosse, Scott D
2008-06-01
To demonstrate the need for standardized data definitions and reporting for early hearing detection and intervention (EHDI) programs collecting information on newborn hearing screening and follow-up, and types of information best collected in a standardized manner. A hypothetical birth cohort was used to show the potential effects of nonstandardized definitions and data classifications on rates of hearing screening, audiologic follow-up, and hearing loss. The true screening rate in this cohort was 92.4%. The calculated rate was between 90.0% and 96.5%, depending on the measure used. Among children documented as screened and referred for follow-up, 61.0% received this testing. Only 49.0% were documented to have been tested. Despite a true prevalence of 3.7 per 1,000 births, only 1.5 per 1,000 children were documented with a hearing loss. Ensuring that children receive recommended follow-up is challenging. Without complete reporting by audiologists to EHDI programs, accurate calculation of performance measures is impossible. Lack of documentation can lead to the overstatement of "loss to follow-up." Also, standardization of measures is essential for programs to evaluate how many children receive recommended services and assess progress toward national goals. A new survey has been implemented to collect more detailed and standardized information about recommended services.
Risk of Bacterial Meningitis in Children with Cochlear Implants
... Hearing Loss Homepage Basics Noise-Induced Hearing Loss Genetics of Hearing Loss Screening & Diagnosis Types of Hearing Loss About Sound Treatment & Intervention Services Learning Language Bacterial Meningitis Studies Data & Statistics EHDI Annual Data 2016 2015 2014 2013 ...
Infant hearing loss: the necessity for early identification.
Harney, C L
2000-01-01
There has been controversy in the health professions about the necessity for newborn infant hearing screening. It is well accepted that patient history or a birth that places the infant in the high-risk registry (HHR) can identify 50% of all infants born with permanent bilateral hearing loss. Two major factors which have been cited as reasons for not screening the well-baby nursery have been poor cost effectiveness and the lack of documentation as to the benefits derived from early identification and intervention. Recent technological developments and published data are presented which indicate that economical well-baby hearing screening can be done in any setting, and that the language acquisition of the infant is permanently affected if the intervention is not done in the first six months after birth.
Skarzynski, Piotr H; Wlodarczyk, Andrzej W; Kochanek, Krzysztof; Pilka, Adam; Jedrzejczak, Wiktor W; Olszewski, Lukasz; Bruski, Lukasz; Niedzielski, Artur; Skarzynski, Henryk
2015-01-01
Hearing disorders among school-age children are a current concern. Continuing studies have been performed in Poland since 2008, and on 2 December 2011 the EU Council adopted Conclusions on the Early Detection and Treatment of Communication Disorders in Children, Including the Use of e-Health Tools and innovative Solutions. The discussion now focuses not only on the efficacy of hearing screening programmes in schoolchildren, but what should be its general aim and what tests it should include? This paper makes the case that it is important to include central auditory processing disorder (CAPD) tests. One such test is the dichotic digits test (DDT). The aim of the presented study was to evaluate the usefulness of the DDT in detecting central hearing disorders in school-age children. During hearing screening programmes conducted in Poland in 2008-2010, exactly 235,664 children (7-12-years-old) were screened in 9,325 schools. Of this number, 7,642 were examined using the DDT test for CAPD. Screening programmes were conducted using the Sense Examination Platform. With the cut-off criterion set at the 5th percentile, results for the DDT applied in a divided attention mode were 11.4% positive for 7-year-olds and 11.3% for 12-year-olds. In the focused attention mode, the comparable result for 12-year-olds was 9.7%. There was a clear right ear advantage. In children with positive DDT results, a higher incidence of other disorders, such as dyslexia, was observed. A test for CAPD should be included in the hearing screening of school-age children. The results of this study form the basis for developing Polish standards in this area.
Molander, Peter; Hesser, Hugo; Weineland, Sandra; Bergwall, Kajsa; Buck, Sonia; Hansson-Malmlöf, Johan; Lantz, Henning; Lunner, Thomas; Andersson, Gerhard
2015-09-01
Psychological distress and psychiatric symptoms are prevalent among people with hearing loss or other audiological conditions, but psychological interventions for these groups are rare. This article describes the study protocol for a randomized controlled trial for evaluating the effect of a psychological treatment delivered over the Internet for individuals with hearing problems and concurrent psychological distress. Participants who are significantly distressed will be randomized to either an 8-week Internet-delivered acceptance-based cognitive behavioral therapy (i.e., acceptance and commitment therapy [ACT]), or wa it-list control. We aim to include measures of distress associated with hearing difficulties, anxiety, and depression. In addition, we aim to measure acceptance associated with hearing difficulties as well as quality of life. The results of the trial may further our understanding of how to best treat people who present problems with both psychological distress and hearing in using the Internet.
Identification of impaired hearing in early childhood.
Wong, D; Shah, C P
1979-01-01
Although the incidence of congenital deafness is high, routine neonatal screening for this problem is not practised, and early identification of congenital or early acquired deafness is relatively rare. Delaying therapy until a child is 3 or more years old severely limits speech development, language acquisition and learning. The commonest causes of delay in diagnosis are the refusal of physicians to listen to the parents' observations, their failure to screen children for hearing and speech problems, and their reluctance to arrange prompt referral for audiologic assessment. Diagnostic delay occurs even though half the children who have impaired hearing are known to be at increased risk. A plea is made for the setting up of a register of infants known to be at risk for impaired hearing. First-contact physicians should be alert to the possibility of hearing problems, particularly in children at high risk. Screening methods for use by nonspecialist practitioners are outlined. Images p535-a p536-a p540-a PMID:387194
[Results of audiometry screening in adolescent workers].
Hartmann, B
1990-11-01
Results of screening audiometry of male youths aged 16 to 25 (n = 3969) in occupations from metallurgy, machine-building industry and traffic are demonstrated. Part of persons they have hearing loss between 5 to 10 percent increases from 2.8% of pupils before starting vocational training to 4.5% or 7.1% of apprentices and 9.7% of skilled workers. The incidence of persons with respective without middle ear inflammation in anamnesis only differ in stages about 20 percent hearing loss. It shows sensitivity of screening audiometry nevertheless there are possibilities of mistakes. Adolescents already may show measurable hearing loss in connection with professional and nonprofessional expositions as well as individual dispositions.
Dewey, Rebecca Susan; Hall, Deborah A; Guest, Hannah; Prendergast, Garreth; Plack, Christopher J; Francis, Susan T
2018-03-09
Rodent studies indicate that noise exposure can cause permanent damage to synapses between inner hair cells and high-threshold auditory nerve fibers, without permanently altering threshold sensitivity. These demonstrations of what is commonly known as hidden hearing loss have been confirmed in several rodent species, but the implications for human hearing are unclear. Our Medical Research Council-funded program aims to address this unanswered question, by investigating functional consequences of the damage to the human peripheral and central auditory nervous system that results from cumulative lifetime noise exposure. Behavioral and neuroimaging techniques are being used in a series of parallel studies aimed at detecting hidden hearing loss in humans. The planned neuroimaging study aims to (1) identify central auditory biomarkers associated with hidden hearing loss; (2) investigate whether there are any additive contributions from tinnitus or diminished sound tolerance, which are often comorbid with hearing problems; and (3) explore the relation between subcortical functional magnetic resonance imaging (fMRI) measures and the auditory brainstem response (ABR). Individuals aged 25 to 40 years with pure tone hearing thresholds ≤20 dB hearing level over the range 500 Hz to 8 kHz and no contraindications for MRI or signs of ear disease will be recruited into the study. Lifetime noise exposure will be estimated using an in-depth structured interview. Auditory responses throughout the central auditory system will be recorded using ABR and fMRI. Analyses will focus predominantly on correlations between lifetime noise exposure and auditory response characteristics. This paper reports the study protocol. The funding was awarded in July 2013. Enrollment for the study described in this protocol commenced in February 2017 and was completed in December 2017. Results are expected in 2018. This challenging and comprehensive study will have the potential to impact diagnostic procedures for hidden hearing loss, enabling early identification of noise-induced auditory damage via the detection of changes in central auditory processing. Consequently, this will generate the opportunity to give personalized advice regarding provision of ear defense and monitoring of further damage, thus reducing the incidence of noise-induced hearing loss. ©Rebecca Susan Dewey, Deborah A Hall, Hannah Guest, Garreth Prendergast, Christopher J Plack, Susan T Francis. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 09.03.2018.
Rolfe, Crystal; Gardner, Benjamin
2016-11-01
Effective hearing loss rehabilitation support options are available. Yet, people often experience delays in receiving rehabilitation support. This study aimed to document support-seeking experiences among a sample of UK adults with hearing loss, and views towards potential strategies to increase rehabilitation support uptake. People with hearing loss were interviewed about their experiences of seeking support, and responses to hypothetical intervention strategies, including public awareness campaigns, a training programme for health professionals, and a national hearing screening programme. Semi-structured qualitative interview design with thematic analysis. Twenty-two people with hearing loss, aged 66-88. Three themes, representing barriers to receiving rehabilitation support and potential areas for intervention, were identified: making the journey from realization to readiness, combatting social stigma, and accessing appropriate services. Barriers to receiving support mostly focused on appraisal of hearing loss symptoms. Interventions enabling symptom appraisal, such as routine screening, or demonstrating how to raise the topic effectively with a loved one, were welcomed. Interventions to facilitate realization of hearing loss should be prioritized. Raising awareness of the symptoms and prevalence of hearing loss may help people to identify hearing problems and reduce stigma, in turn increasing hearing loss acceptance.
Korver, Anna M. H.; Smith, Richard J. H.; Van Camp, Guy; Schleiss, Mark R.; Bitner-Glindzicz, Maria A. K.; Lustig, Lawrence R.; Usami, Shin-ichi; Boudewyns, An N.
2017-01-01
Congenital hearing loss (hearing loss present at birth) is one of the most prevalent chronic conditions in children. In the majority of developed countries, neonatal hearing-screening programmes enable early detection; early intervention will prevent delays in speech and language development and have long-lasting beneficial effects on social and emotional development and quality of life. A hearing loss diagnosis is usually followed by a search for an underlying aetiology. Congenital hearing loss might be attributed to environmental and prenatal factors, which prevail in low-income settings; congenital infections, particularly cytomegalovirus, are also a common risk factor for hearing loss. Genetic causes probably account for the majority of cases in developed countries; mutations can affect any component of the hearing pathway, in particular inner ear homeostasis (endolymph production and maintenance) and mechano-electrical transduction (conversion of a mechanical stimulus into electrochemical activity). Once the underlying cause of hearing loss is established, it might direct therapeutic decision-making and guide prevention and (genetic) counseling. Management options include specific antimicrobial therapies, surgical treatment of cranio-facial abnormalities and hearing aids. An improved understanding of the pathophysiology and molecular mechanisms underlying hearing loss and increased awareness of recent advances in genetic testing will promote the development of new treatment and screening strategies. PMID:28079113
Auditory maturation in premature infants: a potential pitfall for early cochlear implantation.
Hof, Janny R; Stokroos, Robert J; Wix, Eduard; Chenault, Mickey; Gelders, Els; Brokx, Jan
2013-08-01
To describe spontaneous hearing improvement in the first years of life of a number of preterm neonates relative to cochlear implant candidacy. Retrospective case study. Hearing levels of 14 preterm neonates (mean gestational age at birth = 29 weeks) referred after newborn hearing screening were evaluated. Initial hearing thresholds ranged from 40 to 105 dBHL (mean = 85 dBHL). Hearing level improved to normal levels for four neonates and to moderate levels for five, whereas for five neonates, no improvement in hearing thresholds was observed and cochlear implantation was recommended. Three of the four neonates in whom the hearing improved to normal levels were born prior to 28 weeks gestational age. Hearing improvement was mainly observed prior to a gestational age of 80 weeks. Delayed maturation of an immature auditory pathway might be an important reason for referral after newborn hearing screening in premature infants. Caution is advised regarding early cochlear implantation in preterm born infants. Audiological follow-ups until at least 80 weeks gestational age are therefore recommended. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Structured Counseling for Auditory Dynamic Range Expansion.
Gold, Susan L; Formby, Craig
2017-02-01
A structured counseling protocol is described that, when combined with low-level broadband sound therapy from bilateral sound generators, offers audiologists a new tool for facilitating the expansion of the auditory dynamic range (DR) for loudness. The protocol and its content are specifically designed to address and treat problems that impact hearing-impaired persons who, due to their reduced DRs, may be limited in the use and benefit of amplified sound from hearing aids. The reduced DRs may result from elevated audiometric thresholds and/or reduced sound tolerance as documented by lower-than-normal loudness discomfort levels (LDLs). Accordingly, the counseling protocol is appropriate for challenging and difficult-to-fit persons with sensorineural hearing losses who experience loudness recruitment or hyperacusis. Positive treatment outcomes for individuals with the former and latter conditions are highlighted in this issue by incremental shifts (improvements) in LDL and/or categorical loudness judgments, associated reduced complaints of sound intolerance, and functional improvements in daily communication, speech understanding, and quality of life leading to improved hearing aid benefit, satisfaction, and aided sound quality, posttreatment.
Structured Counseling for Auditory Dynamic Range Expansion
Gold, Susan L.; Formby, Craig
2017-01-01
A structured counseling protocol is described that, when combined with low-level broadband sound therapy from bilateral sound generators, offers audiologists a new tool for facilitating the expansion of the auditory dynamic range (DR) for loudness. The protocol and its content are specifically designed to address and treat problems that impact hearing-impaired persons who, due to their reduced DRs, may be limited in the use and benefit of amplified sound from hearing aids. The reduced DRs may result from elevated audiometric thresholds and/or reduced sound tolerance as documented by lower-than-normal loudness discomfort levels (LDLs). Accordingly, the counseling protocol is appropriate for challenging and difficult-to-fit persons with sensorineural hearing losses who experience loudness recruitment or hyperacusis. Positive treatment outcomes for individuals with the former and latter conditions are highlighted in this issue by incremental shifts (improvements) in LDL and/or categorical loudness judgments, associated reduced complaints of sound intolerance, and functional improvements in daily communication, speech understanding, and quality of life leading to improved hearing aid benefit, satisfaction, and aided sound quality, posttreatment. PMID:28286367
[Results from ten years newborn hearing screening in a secondary hospital].
Sequi Canet, José Miguel; Sala Langa, Maria José; Collar Del Castillo, José Ignacio
2016-10-01
A critical analysis is performed on the results of a newborn hearing screening program in a regional hospital. Screening results from 14,247 newborns in our maternity ward from 2002 to 2013. Two step recordings of bilateral otoacoustic emissions (initial and repeat, if failed, at about one month of life). Assessment by clinical brainstem responses. The first step was performed on 14,015 newborns (98.3% of the total) reaching the screening objective. The first step pass figures were 93.7%, which implies a good pass rate with a few patients to repeat. The second step is also good because it has a pass rate of 88.9% of newborns examined (only 0.63% of initial group needed brainstem responses assessment), but 10.6% were lost to follow up, and that is a major problem. In newborns, scheduled for brainstem responses, the loss to follow-up is worse, with a figure of 29.5%, despite the high accuracy of this test given that 69.4% of those assessed showed hearing loss. This figure represents a 0.31% of the initial group, and is a similar to that published for congenital hearing loss. Including patients that were lost to follow up this figure could be greater. Newborn hearing screening is useful but needs stronger control to avoid the follow up loss. In order to achieve this, it is crucial to have a good database and a screening coordinator. Copyright © 2015 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
ERIC Educational Resources Information Center
Hardonk, Stefan; Desnerck, Greetje; Loots, Gerrit; Matthijs, Liesbeth; Van Hove, Geert; Van Kerschaver, Erwin; Sigurjonsdottir, Hanna Bjorg; Vanroelen, Christophe; Louckx, Fred
2011-01-01
The objective of this study is to analyze parental perspectives concerning the use of (re)habilitation services after Universal Newborn Hearing Screening (UNHS). A qualitative study design was used involving children with moderate-to-profound hearing loss who were born between 1999 and 2001 and who are registered in the UNHS program in Flanders,…
A Novel Therapeutic for the Treatment and Prevention of Hearing Loss from Acoustic Trauma
2016-10-01
hearing thresholds at various times post noise exposure. Although numerous exposure conditions were evaluated , this impulse model resulted in a severe...a treatment protocol , to l imit hearing impairment. Establ i sh the kinetics of P13 peptide transfer across the tympanic membrane and quanti fy
Screening for Vision Problems, Including Usher's Syndrome, among Hearing Impaired Students.
ERIC Educational Resources Information Center
Fillman, Robyn D.; And Others
1987-01-01
A screening program for vision problems and Usher's Syndrome (a common cause of deaf-blindness) among 210 hearing-impaired students found 44 percent had significant vision problems and 1 percent had Usher's Syndrome. The program involved an interagency network of school, health care, and support personnel and utilized a dilated ophathalmological…
Is There a Silent Hearing Loss among Children in Jordan?
ERIC Educational Resources Information Center
Alaqrabawi, Wala' S.; Alshawabka, Amneh Z.; Al-Addasi, Zainab M.
2016-01-01
This study measured the prevalence of hearing loss among school children in Jordan. A random sample of 1649 children (990 males and 659 females) was collected from randomly chosen 40 schools in Amman. Screening was conducted between November 2010 and October 2014. Otoscopic examination, tympanometry, and audiometry were used for screening. Based…
Suzuki, Hideaki; Wakasugi, Tetsuro; Kitamura, Takuro; Koizumi, Hiroki; Do, Ba Hung; Ohbuchi, Toyoaki
2018-04-01
We studied the effect of intratympanic steroid administration with different total injection times on hearing outcomes in patients with idiopathic sudden sensorineural hearing loss (ISSNHL). The subjects were 191 consecutive patients (192 ears) with ISSNHL (hearing level ≥40 dB, interval between onset and treatment ≤30 days). They received systemic prednisolone (100 mg followed by tapered doses) combined with intratympanic injection of dexamethasone (4 mg/ml). Intratympanic injection was performed 4 times (days 1, 2, 4, and 7) in 92 patients (92 ears) or 2 times (days 1 and 2) in 99 patients (100 ears). The hearing outcomes were evaluated at 1 week from the start of treatment and 1 to 2 months after the completion of treatment. There was no significant difference in hearing outcomes between the 4- and 2-injection groups at either time point. Multiple regression analysis also showed that the hearing level after treatment did not depend on the total number of intratympanic steroid injections. These results indicate that a protocol using only 2 intratympanic steroid injections exerts a sufficient effect on the hearing outcomes of ISSNHL. This simplified treatment protocol would be greatly beneficial to relieve the physical and mental stress of patients.
Paglialonga, Alessia; Tognola, Gabriella; Grandori, Ferdinando
2014-09-01
A novel, user-operated test of suprathreshold acuity in noise for use in adult hearing screening (AHS) was developed. The Speech Understanding in Noise test (SUN) is a speech-in-noise test that makes use of a list of vowel-consonant-vowel (VCV) stimuli in background noise presented in a three-alternative forced choice (3AFC) paradigm by means of a touch sensitive screen. The test is automated, easy-to-use, and provides self-explanatory results (i.e., 'no hearing difficulties', or 'a hearing check would be advisable', or 'a hearing check is recommended'). The test was developed from its building blocks (VCVs and speech-shaped noise) through two main steps: (i) development of the test list through equalization of the intelligibility of test stimuli across the set and (ii) optimization of the test results through maximization of the test sensitivity and specificity. The test had 82.9% sensitivity and 85.9% specificity compared to conventional pure-tone screening, and 83.8% sensitivity and 83.9% specificity to identify individuals with disabling hearing impairment. Results obtained so far showed that the test could be easily performed by adults and older adults in less than one minute per ear and that its results were not influenced by ambient noise (up to 65dBA), suggesting that the test might be a viable method for AHS in clinical as well as non-clinical settings. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hearing Loss in Hospice and Palliative Care: A National Survey of Providers.
Smith, Alexander K; Ritchie, Christine S; Wallhagen, Margaret L
2016-08-01
Age-related hearing loss can impair patient-provider communication about symptom management, goals of care, and end-of-life decision-making. To determine whether hospice and palliative care providers screen for or received training about hearing loss, believe it impacts patient care, and use strategies to optimize communication. This was a national survey of hospice and palliative care providers conducted via email and social media. Survey questions were pilot tested with multidisciplinary providers in San Francisco. Of 510 responses (55% age 50+ years, 65% female, 64% in practice 5+ years, 57% practiced hospital-based palliative care, 45% hospice), 315 were physicians, 50 nurses, 48 nurse practitioners, 58 social workers, and 39 chaplains. Ninety-one percent reported that hearing loss has some or great impact on the quality of care for older adults. Eighty-eight percent recalled a situation where hearing loss created a communication problem with a patient and 56% a communication problem with a caregiver. Eighty-seven percent of physicians, nurses, and nurse practitioners reported not screening for hearing loss. Although 61% felt comfortable with their communication skills for patients with hearing loss, only 21% reported having received formal training in its management, 31% were unfamiliar with resources for patients with hearing loss, and 38% had never heard of a pocket talker amplification device. Hospice and palliative medicine providers believe age-related hearing loss impacts care yet most do not screen. Although they feel they are managing well, few have formal training. Knowledge about management approaches and resources is suboptimal. Published by Elsevier Inc.
Progress towards early detection services for infants with hearing loss in developing countries
Olusanya, Bolajoko O; Swanepoel, De Wet; Chapchap, Mônica J; Castillo, Salvador; Habib, Hamed; Mukari, Siti Z; Martinez, Norberto V; Lin, Hung-Ching; McPherson, Bradley
2007-01-01
Background Early detection of infants with permanent hearing loss through infant hearing screening is recognised and routinely offered as a vital component of early childhood care in developed countries. This article investigates the initiatives and progress towards early detection of infants with hearing loss in developing countries against the backdrop of the dearth of epidemiological data from this region. Methods A cross-sectional, descriptive study based on responses to a structured questionnaire eliciting information on the nature and scope of early hearing detection services; strategies for financing services; parental and professional attitudes towards screening; and the performance of screening programmes. Responses were complemented with relevant data from the internet and PubMed/Medline. Results Pilot projects using objective screening tests are on-going in a growing number of countries. Screening services are provided at public/private hospitals and/or community health centres and at no charge only in a few countries. Attitudes amongst parents and health care workers are typically positive towards such programmes. Screening efficiency, as measured by referral rate at discharge, was generally found to be lower than desired but several programmes achieved other international benchmarks. Coverage is generally above 90% but poor follow-up rates remain a challenge in some countries. The mean age of diagnosis is usually less than six months, even for community-based programmes. Conclusion Lack of adequate resources by many governments may limit rapid nationwide introduction of services for early hearing detection and intervention, but may not deter such services altogether. Parents may be required to pay for services in some settings in line with the existing practice where healthcare services are predominantly financed by out-of-pocket spending rather than public funding. However, governments and their international development partners need to complement current voluntary initiatives through systematic scaling-up of public awareness and requisite manpower development towards sustainable service capacities at all levels of healthcare delivery. PMID:17266763
Socio-demographic determinants of hearing impairment studied in 103,835 term babies.
Van Kerschaver, Erwin; Boudewyns, An N; Declau, Frank; Van de Heyning, Paul H; Wuyts, Floris L
2013-02-01
Serious hearing problems appear in approximately one in 1000 newborns. In 2000, the Joint Committee on Infant Hearing defined a list of risk factors for neonatal hearing impairment relating to health, physical characteristics and family history. The aim of this study is to determine which personal, environmental and social factors are associated with the prevalence of congenital hearing impairment (CHI). The entire population of 103,835 term newborns in Flanders, Belgium, was tested by a universal neonatal hearing screening (UNHS) programme using automated auditory brainstem responses (AABR). In the case of a positive result, a CHI diagnosis was verified in specialized referral centres. Socio-demographic risk factors were investigated across the entire population to study any relationship with CHI. The prevalence of bilateral CHI of 35 dB nHL (normal hearing level) or more was 0.87/1000 newborns. The sensitivity and specificity of the screening test were 94.02 and 99.96%, respectively. The socio-demographic factors of gender, birth order, birth length, feeding type, level of education and origin of the mother were found to be independent predictors of CHI. The socio-demographic factors found to be associated with CHI extend the list of classic risk factors as defined by the American Academy of Pediatrics (AAP). Assessment of these additional factors may alert the treating physician to the increased risk of newborn hearing impairment and urge the need for accurate follow-up. Moreover, this extended assessment may improve decision making in medical practice and screening policy.
Bringing Text Display Digital Radio to Consumers with Hearing Loss
ERIC Educational Resources Information Center
Sheffield, Ellyn G.; Starling, Michael; Schwab, Daniel
2011-01-01
Radio is migrating to digital transmission, expanding its offerings to include captioning for individuals with hearing loss. Text display radio requires a large amount of word throughput with minimal screen display area, making good user interface design crucial to its success. In two experiments, we presented hearing, hard-of-hearing, and deaf…
Rolfe, Crystal; Gardner, Benjamin
2016-01-01
Abstract Objective: Effective hearing loss rehabilitation support options are available. Yet, people often experience delays in receiving rehabilitation support. This study aimed to document support-seeking experiences among a sample of UK adults with hearing loss, and views towards potential strategies to increase rehabilitation support uptake. People with hearing loss were interviewed about their experiences of seeking support, and responses to hypothetical intervention strategies, including public awareness campaigns, a training programme for health professionals, and a national hearing screening programme. Design: Semi-structured qualitative interview design with thematic analysis. Study sample: Twenty-two people with hearing loss, aged 66–88. Results: Three themes, representing barriers to receiving rehabilitation support and potential areas for intervention, were identified: making the journey from realization to readiness, combatting social stigma, and accessing appropriate services. Barriers to receiving support mostly focused on appraisal of hearing loss symptoms. Interventions enabling symptom appraisal, such as routine screening, or demonstrating how to raise the topic effectively with a loved one, were welcomed. Conclusions: Interventions to facilitate realization of hearing loss should be prioritized. Raising awareness of the symptoms and prevalence of hearing loss may help people to identify hearing problems and reduce stigma, in turn increasing hearing loss acceptance. PMID:27379464
Newborn hearing screening programme in Belgium: a consensus recommendation on risk factors.
Vos, Bénédicte; Senterre, Christelle; Lagasse, Raphaël; Levêque, Alain
2015-10-16
Understanding the risk factors for hearing loss is essential for designing the Belgian newborn hearing screening programme. Accordingly, they needed to be updated in accordance with current scientific knowledge. This study aimed to update the recommendations for the clinical management and follow-up of newborns with neonatal risk factors of hearing loss for the newborn screening programme in Belgium. A literature review was performed, and the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) system assessment method was used to determine the level of evidence quality and strength of the recommendation for each risk factor. The state of scientific knowledge, levels of evidence quality, and graded recommendations were subsequently assessed using a three-round Delphi consensus process (two online questionnaires and one face-to-face meeting). Congenital infections (i.e., cytomegalovirus, toxoplasmosis, and syphilis), a family history of hearing loss, consanguinity in (grand)parents, malformation syndromes, and foetal alcohol syndrome presented a 'high' level of evidence quality as neonatal risk factors for hearing loss. Because of the sensitivity of auditory function to bilirubin toxicity, hyperbilirubinaemia was assessed at a 'moderate' level of evidence quality. In contrast, a very low birth weight, low Apgar score, and hospitalisation in the neonatal intensive care unit ranged from 'very low' to 'low' levels, and ototoxic drugs were evidenced as 'very low'. Possible explanations for these 'very low' and 'low' levels include the improved management of these health conditions or treatments, and methodological weaknesses such as confounding effects, which make it difficult to conclude on individual risk factors. In the recommendation statements, the experts emphasised avoiding unidentified neonatal hearing loss and opted to include risk factors for hearing loss even in cases with weak evidence. The panel also highlighted the cumulative effect of risk factors for hearing loss. We revised the recommendations for the clinical management and follow-up of newborns exhibiting neonatal risk factors for hearing loss on the basis of the aforementioned evidence-based approach and clinical experience from experts. The next step is the implementation of these findings in the Belgian screening programme.
National Newborn Screening and Genetics Resource Center
... GENERAL INFORMATION Conditions Screened by US Programs General Resources Genetics Birth Defects Hearing Screening FOR PROFESSIONALS ACT Sheets(ACMG) General Resources Newborn Screening Genetics Birth Defects FOR FAMILIES FAQs ...
Evaluation of the risk of noise-induced hearing loss among unscreened male industrial workers.
Prince, Mary M; Gilbert, Stephen J; Smith, Randall J; Stayner, Leslie T
2003-02-01
Variability in background risk and distribution of various risk factors for hearing loss may explain some of the diversity in excess risk of noise-induced hearing loss (NIHL). This paper examines the impact of various risk factors on excess risk estimates of NIHL using data from the 1968-1972 NIOSH Occupational Noise and Hearing Survey (ONHS). Previous analyses of a subset of these data focused on 1172 highly "screened" workers. In the current analysis, an additional 894 white males (609 noise-exposed and 285 controls), who were excluded for various reasons (i.e., nonoccupational noise exposure, otologic or medical conditions affecting hearing, prior occupational noise exposure) have been added 2066) to assess excess risk of noise-induced material impairment in an unscreened population. Data are analyzed by age, duration of exposure, and sound level (8-h TWA) for four different definitions of noise-induced hearing impairment, defined as the binaural pure-tone average (PTA) hearing threshold level greater than 25 dB for the following frequencies: (a) 1-4 kHz (PTA1234), (b) 1-3 kHz (PTA123), (c) 0.5, 1, and 2 kHz (PTA512), and (d) 3, 4, and 6 kHz (PTA346). Results indicate that populations with higher background risks of hearing loss may show lower excess risks attributable to noise relative to highly screened populations. Estimates of lifetime excess risk of hearing impairment were found to be significantly different between screened and unscreened population for noise levels greater than 90 dBA. Predicted age-related risk of material hearing impairment in the ONHS unscreened population was similar to that predicted from Annex B and C of ANSI S3.44 for ages less than 60 years. Results underscore the importance of understanding differential risk patterns for hearing loss and the use of appropriate reference (control) populations when evaluating risk of noise-induced hearing impairment among contemporary industrial populations.
2014-01-01
Background The Kingdon model, based on the convergence of three streams (problem, policy, and politics) and the opening of a policy window, analyses the process by which a health issue is placed on the political agenda. We used this model to document the political agenda-setting process of the newborn hearing screening programme in Belgium. Methods A qualitative study based on a document review and on semi-directed interviews was carried out. The interviews were conducted with nine people who had played a role in putting the issue in question on the political agenda, and the documents reviewed included scientific literature and internal reports and publications from the newborn hearing screening programme. The thematic analysis of the data collected was carried out on the basis of the Kingdon model’s three streams. Results The political agenda-setting of this screening programme was based on many factors. The problem stream included factors external to the context under study, such as the technological developments and the contribution of the scientific literature which led to the recommendation to provide newborn hearing screening. The two other streams (policy and politics) covered factors internal to the Belgian context. The fact that it was locally feasible with financial support, the network of doctors convinced of the need for newborn hearing screening, the drafting of various proposals, and the search for financing were all part of the policy stream. The Belgian political context and the policy opportunities concerning preventive medicine were identified as significant factors in the third stream. When these three streams converged, a policy window opened, allowing newborn hearing screening onto the political agenda and enabling the policy decision for its introduction. Conclusions The advantage of applying the Kingdon model in our approach was the ability to demonstrate the political agenda-setting process, using the three streams. This made it possible to identify the many factors involved in the process. However, the roles of the stakeholders and of the context were somewhat inexplicit in this model. PMID:24986647
Vos, Bénédicte; Lagasse, Raphaël; Levêque, Alain
2014-07-01
The Kingdon model, based on the convergence of three streams (problem, policy, and politics) and the opening of a policy window, analyses the process by which a health issue is placed on the political agenda. We used this model to document the political agenda-setting process of the newborn hearing screening programme in Belgium. A qualitative study based on a document review and on semi-directed interviews was carried out. The interviews were conducted with nine people who had played a role in putting the issue in question on the political agenda, and the documents reviewed included scientific literature and internal reports and publications from the newborn hearing screening programme. The thematic analysis of the data collected was carried out on the basis of the Kingdon model's three streams. The political agenda-setting of this screening programme was based on many factors. The problem stream included factors external to the context under study, such as the technological developments and the contribution of the scientific literature which led to the recommendation to provide newborn hearing screening. The two other streams (policy and politics) covered factors internal to the Belgian context. The fact that it was locally feasible with financial support, the network of doctors convinced of the need for newborn hearing screening, the drafting of various proposals, and the search for financing were all part of the policy stream. The Belgian political context and the policy opportunities concerning preventive medicine were identified as significant factors in the third stream. When these three streams converged, a policy window opened, allowing newborn hearing screening onto the political agenda and enabling the policy decision for its introduction. The advantage of applying the Kingdon model in our approach was the ability to demonstrate the political agenda-setting process, using the three streams. This made it possible to identify the many factors involved in the process. However, the roles of the stakeholders and of the context were somewhat inexplicit in this model.
Screening the High-Risk Newborn for Hearing Loss: The Crib-O-Gram v the Auditory Brainstem Response.
ERIC Educational Resources Information Center
Cox, L. Clarke
1988-01-01
Presented are a rationale for identifying hearing loss in infancy and a history of screening procedures. The Crib-O-Gram and auditory brainstem response (ABR) tests are evaluated for reliability, validity, and cost-effectiveness. The ABR is recommended, and fully automated ABR instrumentation, which lowers expenses for trained personnel and…
The Need for Hearing Conservation in Our (Jos Municipality) Public Schools. Brief Research Report.
ERIC Educational Resources Information Center
Boison, Kwame Bessa
1986-01-01
Audiometric screening tests administered to students ages 5-21 in five Nigerian schools (N=2315) revealed hearing problems in 13.5% of the student population. Among findings was a high incidence of acute suppurative otitis media. Related recommendations include twice-yearly audiometric screening for children perceived to be at risk. (JW)
Delays in Diagnosis of Congenital Hearing Loss in Rural Children
Bush, Matthew L.; Bianchi, Kristin; Lester, Cathy; Shinn, Jennifer B.; Gal, TJ; Fardo, David W.; Schoenberg, Nancy
2013-01-01
Objective To examine the incidence of pediatric congenital hearing loss and the timing of diagnosis in a rural region of hearing healthcare disparity. Study design Data from the Kentucky newborn hearing-screening program was accessed to determine the incidence of congenital hearing loss in Kentucky, both in the extremely rural region of Appalachia and non-Appalachian region of Kentucky. We also performed a retrospective review of records of children with congenital hearing loss at our institution to determine the timing of diagnostic testing. Results In Kentucky, during 2009–2011, there were 6,970 newborns who failed hearing screening; the incidence of newborn hearing loss was 1.71 per 1000 births (1.28/1000 in Appalachia and 1.87/1000 in non-Appalachia). 23.8% of Appalachian newborns compared with 17.3% of non-Appalachian children failed to obtain follow-up diagnostic testing. Children from Appalachia were significantly delayed in obtaining a final diagnosis of hearing loss compared with children from non-Appalachian regions (p=0.04). Conclusion Congenital hearing loss in children from rural regions with hearing healthcare disparities is a common problem and these children are at risk for a delay in the timing of diagnosis, which has the potential to limit language and social development. It is important to further assess the causative factors and develop interventions that can address this hearing healthcare disparity issue. PMID:24183213
ERIC Educational Resources Information Center
Fitzpatrick, Elizabeth; Grandpierre, Viviane; Durieux-Smith, Andrée; Gaboury, Isabelle; Coyle, Doug; Na, Eunjung; Sallam, Nusaiba
2016-01-01
Children with mild bilateral and unilateral hearing loss are now commonly identified early through newborn hearing screening initiatives. There remains considerable uncertainty about how to support parents and about which services to provide for children with mild bilateral and unilateral hearing loss. The goal of this study was to learn about…
Deepthi, R; Kasthuri, Arvind
2012-01-01
Hearing loss is a potentially disabling problem among elderly leading to physical and social dysfunction. Though audiometric assessment of hearing loss is considered as gold standard, it is not feasible in community settings. Several questionnaires measuring hearing handicap have been developed. Knowledge regarding applicability of these questionnaires among rural elderly is limited, hence a study was planned to validate single question and Shortened Hearing Handicap Inventory for Elderly (HHIE-S) in detecting hearing loss against pure tone-audiometry among rural Indian elderly. A single question 'do you feel you have a hearing loss?' and the HHIE-S was administered to 175 elderly in two rural areas. Hearing ability was assessed using pure tone audiometry. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of both screening tools were compared with pure tone averages (PTAs) greater than 25, 40 and 55 dB hearing level (mild, moderate and severe hearing loss, respectively). The single question yielded low sensitivity (30.9%) and high specificity (93.9%) for mild hearing loss. Similarly HHIE-S yielded a sensitivity of 26.2% and specificity of 95.9%. Sensitivity with single question increased to 76.2% and specificity decreased to 83.1% with severe hearing loss. Sensitivity with HHIE-S also increased to 76.2% and specificity decreased to 87.7% with severe hearing loss. These hearing screening questionnaires will be useful in identifying more disabling hearing losses among rural elderly which helps in rehabilitation services planning. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Cristobal, R; Oghalai, J S
2013-01-01
An association between birth weight <1500 g (very low birth weight (VLBW)) and hearing loss has been long recognised. As universal hearing screening programmes have become widely implemented and the survival rate of VLBW babies in modern intensive care units has increased, we have gained a substantially better understanding of the nature of this problem. However, many gaps in our knowledge base exist. This review describes recent data on hearing loss in the VLBW population and explains the current level of understanding about the physiological basis underlying the auditory deficits in these patients. Although VLBW alone may not have a severe impact on hearing, it is commonly associated with multiple other risk factors that can alter hearing in a synergistic fashion. Therefore, the risk of hearing loss is substantially higher than in the general newborn population. Also, it is important to perform a more comprehensive audiometric evaluation than standard otoacoustic emission screening for infants who are in the neonatal intensive care unit in order not to miss hearing loss due to retrocochlear pathology. Furthermore, children with VLBW are also at increased risk of experiencing progressive or delayed-onset hearing loss, and thus should continue to have serial hearing evaluations after discharge from the neonatal intensive care unit. PMID:18941031
Hall, Deborah A; Guest, Hannah; Prendergast, Garreth; Plack, Christopher J; Francis, Susan T
2018-01-01
Background Rodent studies indicate that noise exposure can cause permanent damage to synapses between inner hair cells and high-threshold auditory nerve fibers, without permanently altering threshold sensitivity. These demonstrations of what is commonly known as hidden hearing loss have been confirmed in several rodent species, but the implications for human hearing are unclear. Objective Our Medical Research Council–funded program aims to address this unanswered question, by investigating functional consequences of the damage to the human peripheral and central auditory nervous system that results from cumulative lifetime noise exposure. Behavioral and neuroimaging techniques are being used in a series of parallel studies aimed at detecting hidden hearing loss in humans. The planned neuroimaging study aims to (1) identify central auditory biomarkers associated with hidden hearing loss; (2) investigate whether there are any additive contributions from tinnitus or diminished sound tolerance, which are often comorbid with hearing problems; and (3) explore the relation between subcortical functional magnetic resonance imaging (fMRI) measures and the auditory brainstem response (ABR). Methods Individuals aged 25 to 40 years with pure tone hearing thresholds ≤20 dB hearing level over the range 500 Hz to 8 kHz and no contraindications for MRI or signs of ear disease will be recruited into the study. Lifetime noise exposure will be estimated using an in-depth structured interview. Auditory responses throughout the central auditory system will be recorded using ABR and fMRI. Analyses will focus predominantly on correlations between lifetime noise exposure and auditory response characteristics. Results This paper reports the study protocol. The funding was awarded in July 2013. Enrollment for the study described in this protocol commenced in February 2017 and was completed in December 2017. Results are expected in 2018. Conclusions This challenging and comprehensive study will have the potential to impact diagnostic procedures for hidden hearing loss, enabling early identification of noise-induced auditory damage via the detection of changes in central auditory processing. Consequently, this will generate the opportunity to give personalized advice regarding provision of ear defense and monitoring of further damage, thus reducing the incidence of noise-induced hearing loss. PMID:29523503
Pye, Annie; Charalambous, Anna Pavlina; Leroi, Iracema; Thodi, Chrysoulla; Dawes, Piers
2017-11-01
Cognitive screening tests frequently rely on items being correctly heard or seen. We aimed to identify, describe, and evaluate the adaptation, validity, and availability of cognitive screening and assessment tools for dementia which have been developed or adapted for adults with acquired hearing and/or vision impairment. Electronic databases were searched using subject terms "hearing disorders" OR "vision disorders" AND "cognitive assessment," supplemented by exploring reference lists of included papers and via consultation with health professionals to identify additional literature. 1,551 papers were identified, of which 13 met inclusion criteria. Four papers related to tests adapted for hearing impairment; 11 papers related to tests adapted for vision impairment. Frequently adapted tests were the Mini-Mental State Examination (MMSE) and the Montreal Cognitive Assessment (MOCA). Adaptations for hearing impairment involved deleting or creating written versions for hearing-dependent items. Adaptations for vision impairment involved deleting vision-dependent items or spoken/tactile versions of visual tasks. No study reported validity of the test in relation to detection of dementia in people with hearing/vision impairment. Item deletion had a negative impact on the psychometric properties of the test. While attempts have been made to adapt cognitive tests for people with acquired hearing and/or vision impairment, the primary limitation of these adaptations is that their validity in accurately detecting dementia among those with acquired hearing or vision impairment is yet to be established. It is likely that the sensitivity and specificity of the adapted versions are poorer than the original, especially if the adaptation involved item deletion. One solution would involve item substitution in an alternative sensory modality followed by re-validation of the adapted test.
Farzal, Zainab; Walsh, Jonathan; Ahmad, Faisal I; Roberts, Jason; Ferns, Sunita J; Zdanski, Carlton J
2018-03-01
Objective The purpose is to determine the prevalence of electrocardiogram (ECG) abnormalities, including borderline and prolonged QT, among screened children with sensorineural hearing loss (SNHL) and to analyze their subsequent medical workup. Study Design Institutional Review Board-approved case series with chart review. Setting Tertiary academic center. Subjects and Methods Cases from 1996 to 2014 involving pediatric patients (N = 1994) with SNHL were analyzed. Abnormal ECGs were categorized as borderline/prolonged QT or other. A board-certified pediatric cardiologist retrospectively determined the clinical significance of ECG changes. For follow-up analysis, children with heart disease, known syndromes, or inaccessible records were excluded. Results Among 772 children who had ECGs, 215 (27.8%) had abnormal results: 35 (4.5%) with QT abnormalities and 180 (23.3%) with other abnormalities. For children with QT abnormalities meeting inclusion criteria (n = 30), follow-up measures included cardiology referral (46.6%), repeat ECG by ear, nose, and throat (ENT) specialist (20%), clearance by ENT specialist with clinical correlation and/or comparison with old ECGs (20%), and pediatrician follow-up (6.7%). Documentation of further workup by ENT or referral was absent for 6.7%. For children with other ECG changes meeting inclusion criteria (n = 136), abnormalities were documented for 57 (41.9%); normal QT without other abnormality was documented for 18 (13.2%). The most common follow-up referrals were to pediatricians (16.9%) and cardiologists (10.3%). Among patients with clinically significant non-QT abnormalities mandating further evaluation (n = 122), 38 (31.1%) had documented follow-up in medical records. Conclusion There is a high prevalence of ECG abnormalities among children with congenital SNHL. If findings are confirmed by future studies, screening should be considered for congenital unilateral or bilateral SNHL, regardless of severity. We describe a standardized protocol for ECG screening/follow-up.
Molander, Peter; Nordqvist, Peter; Öberg, Marie; Lunner, Thomas; Lyxell, Björn; Andersson, Gerhard
2013-01-01
Objectives For the last decade a host of different projects have been launched to allow persons who are concerned about their hearing status to quickly and at a low cost test their hearing ability. Most often, this is carried out without collecting complementary information that could be correlated with hearing impairment. In this two-part study we first, present the development and validation of a novel Internet-based hearing test, and second, report on the associations between this test and phonological representation, quality of life and self-reported hearing difficulties. Design Cross-sectional study. Setting An opportunity sample of participants was recruited at the Stockholm central station for the first study. All parts of the second study were conducted via the Internet, with testing and self-report forms adapted for online use. Participants The first part of the study was carried out in direct contact with the participants, and participants from the second study were recruited by means of advertisements in newspapers and on webpages. The only exclusion criterion was that participants had to be over 18 years old. Most participants were between 60 and 69 years old. There were almost an equal number of men and women (total n=316). Outcome measures 48 participants failed the Internet-based hearing screening test. The group failing the test reported more problems on the Amsterdam Inventory of Auditory Disability. In addition, they were found to have diminished phonological representational skills. However, no difference in quality of life was found. Conclusions Almost one in five participants was in need of contacting their local hearing clinic. This group had more complaints regarding tinnitus and hyperacusis, rated their own hearing as worse than those who passed, and had a poorer capability of generating accurate phonological representations. This study suggests that it is feasible to screen for hearing status online, and obtain valid data. PMID:24041846
The Impact of the National Newborn Hearing Screening Programme on Educational Services in England
ERIC Educational Resources Information Center
McCracken, Wendy; Young, Alys; Tattersall, Helen; Uus, Kai; Bamford, John
2005-01-01
This article presents results related to the impact on educational support services of the introduction of the first phase of the national Newborn Hearing Screening Programme (NHSP) in England. This study was funded by the Department of Health and undertaken as one element of a national evaluation of NHSP across a range of domains. It presents…
ERIC Educational Resources Information Center
Hardonk, Stefan; Desnerck, Greetje; Loots, Gerrit; Van Hove, Geert; Van Kerschaver, Erwin; Sigurjonsdottir, Hanna Bjorg; Vanroelen, Christophe; Louckx, Fred
2011-01-01
The objective of this study is to examine the early care trajectories of congenitally deaf children from a parental perspective, starting with universal neonatal hearing screenings. The analysis using a three-dimensional care trajectory concept is aimed at developing a basic typology of postscreening care trajectories. Children with…
The Effect of Integrated Hearing Protection Surround Levels on Sound Localization
2015-02-01
perceived hearing loss, and tinnitus . 4 DRDC-RDDC-2015-R012 Individuals who met the telephone screening criteria were examined by...and military service: Implications for hearing loss and tinnitus . Institute of Medicine of the National Academy of Science. National Academies Press
[Issues Related to Screening and Caring for Newborns With Hearing Impairments].
Liou, Mei-Show; Tsao, Ying
2016-12-01
The critical period for auditory development in humans begins at around the 20th gestational week and continues until 3 years of age. Both genetic and environmental factors are known to cause impaired hearing. Without early identification and intervention, hearing-impaired children face a high risk of experiencing significant difficulties with speech and language development, social behavior, and emotional functioning. Two types of commonly used hearing screening technologies include transient evoked otoacoustic emission (TEOAE) and automated auditory brainstem response (aABR). aABR is considered to have high sensitivity and specificity, to have a relatively low referral rate, and to generate a relatively low rate of false-positive results in identifying newborn hearing impairment. The present paper outlines the psychosocial issues that are commonly experienced by parents of hearing-impaired children. Parents and other family members may benefit from medical, financial, social, and education supports in order to facilitate their adjustment to this challenging situation. The relevant literature is reviewed and recommendations for improving care for this population are provided.
Li, Degao; Zhang, Fan; Zeng, Xihong
2016-01-01
An affective priming task was used with two cohorts of college students, one deaf or hard of hearing (D/HH), the other hearing, in two experiments. The same set of affective-word targets, preceded by "※※" in Experiment 1 but by affective-word primes of the same valence as the targets in Experiment 2, were presented vertically above or below the screen center. Stimuli that preceded the targets were shown at the screen center. D/HH participants generally performed more poorly than hearing participants, but both groups performed similarly in that both did better on the positive targets than on the negative in both experiments, and on supporting metaphorical associations between valence and vertical positions (Meier & Robinson, 2004), as indicated by reaction times, in Experiment 2. The researchers concluded that D/HH and hearing college students perform similarly in developing cognition-grounded representations of affective words in written language.
Ramkumar, Vidya; Selvakumar, K; Vanaja, C S; Hall, James W; Nagarajan, Roopa; Neethi, J
2016-10-01
Tele-diagnostic audiological testing in a hearing screening program for infants and young children is a novel practice, and this study is the first to explore its application in a rural community. It is important to understand parental perceptions and confidence when introducing a new process such as tele-audiological diagnostic testing in rural areas. A questionnaire with 17 rater-administered items was designed to elicit comments concerning the quality of tele-hearing testing and video-conferencing, access to tele-hearing testing, and parents' attitudes regarding tele-hearing testing in the village. The questionnaire was administered by an audiologist not involved in tele-diagnostic testing to avoid bias. Parents perceived tele-hearing testing as equal in quality to in-person testing. Technical factors such as good video-conferencing quality and logistical factors such as ease of access due to reasonable travel time to testing facility could have influenced these perceptions. While these results show tele-hearing testing is an acceptable alternative, occasional poor signal quality should be addressed prior to large-scale implementation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Maidment, David W; Barker, Alex B; Xia, Jun; Ferguson, Melanie A
2016-10-27
Hearing loss is a major public health concern, affecting over 11 million people in the UK. While hearing aids are the most common clinical intervention for hearing loss, the majority of people that would benefit from using hearing aids do not take them up. Recent technological advances have led to a rapid increase of alternative listening devices to conventional hearing aids. These include hearing aids that can be customised using a smartphone, smartphone-based 'hearing aid' apps, personal sound amplification products and wireless hearing products. However, no systematic review has been published evaluating whether alternative listening devices are an effective management strategy for people with hearing loss. The objective of this systematic review is to assess whether alternative listening devices are an effective intervention for adults with hearing loss. Methods are reported according to the Preferred Reporting Items for Systematic reviews and Meta-analyses Protocols (PRISMA-P) 2015 checklist. Retrospective or prospective studies, randomised controlled trials, non-randomised controlled trials, and before-after comparison studies will be eligible for inclusion. We will include studies with adult participants (≥18 years) with a mild or moderate hearing loss. The intervention should be an alternative listening device to a conventional hearing aid (comparison). Studies will be restricted to outcomes associated with the consequences of hearing loss. We will search relevant databases to identify published, completed but unpublished and ongoing trials. The overall quality of included evidence will be evaluated using the GRADE system, and meta-analysis performed if appropriate. No ethical issues are foreseen. The findings will be reported at national and international conferences, primarily audiology, and ear, nose and throat, and in a peer-reviewed journal using the PRISMA guidelines. PROSPERO CRD4201502958. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Barker, Alex B; Xia, Jun
2016-01-01
Introduction Hearing loss is a major public health concern, affecting over 11 million people in the UK. While hearing aids are the most common clinical intervention for hearing loss, the majority of people that would benefit from using hearing aids do not take them up. Recent technological advances have led to a rapid increase of alternative listening devices to conventional hearing aids. These include hearing aids that can be customised using a smartphone, smartphone-based ‘hearing aid’ apps, personal sound amplification products and wireless hearing products. However, no systematic review has been published evaluating whether alternative listening devices are an effective management strategy for people with hearing loss. Methods and analysis The objective of this systematic review is to assess whether alternative listening devices are an effective intervention for adults with hearing loss. Methods are reported according to the Preferred Reporting Items for Systematic reviews and Meta-analyses Protocols (PRISMA-P) 2015 checklist. Retrospective or prospective studies, randomised controlled trials, non-randomised controlled trials, and before-after comparison studies will be eligible for inclusion. We will include studies with adult participants (≥18 years) with a mild or moderate hearing loss. The intervention should be an alternative listening device to a conventional hearing aid (comparison). Studies will be restricted to outcomes associated with the consequences of hearing loss. We will search relevant databases to identify published, completed but unpublished and ongoing trials. The overall quality of included evidence will be evaluated using the GRADE system, and meta-analysis performed if appropriate. Ethics and dissemination No ethical issues are foreseen. The findings will be reported at national and international conferences, primarily audiology, and ear, nose and throat, and in a peer-reviewed journal using the PRISMA guidelines. Review registration number PROSPERO CRD4201502958. PMID:27789514
The use of transient evoked otoacoustic emissions as a hearing screen following grommet insertion.
Dale, O T; McCann, L J; Thio, D; Wells, S C; Drysdale, A J
2011-07-01
This study aimed to evaluate the sensitivity of transient evoked otoacoustic emission testing as a screening tool for hearing loss in children, after grommet insertion. A prospective study was conducted of 48 children (91 ears) aged three to 16 years who had undergone grommet insertion for glue ear. At post-operative review, pure tone audiometry was performed followed by transient evoked otoacoustic emission testing. Outcomes for both tests, in each ear, were compared. The pure tone audiometry threshold was ≤ 20 dB in 85 ears (93.4 per cent), 25 dB in two ears (2.2 per cent) and ≥ 30 dB in four ears (4.4 per cent). Transient evoked otoacoustic emissions were detected in 69 ears (75.8 per cent). The sensitivity of transient evoked otoacoustic emission testing for detecting hearing loss was 100 per cent for ≥ 30 dB loss but only 66.7 per cent for ≥ 25 dB loss. Transient evoked otoacoustic emission testing offers a sensitive means of detecting hearing loss of ≥ 30 dB following grommet insertion in children. However, the use of such testing as a screening tool may miss some cases of mild hearing loss.
ERIC Educational Resources Information Center
Hild, U.; Hey, C.; Baumann, U.; Montgomery, J.; Euler, H. A.; Neumann, K.
2008-01-01
Background: Persons with intellectual disabilities (ID) are at increased risk for hearing impairment which often remains undetected. If left untreated, such hearing impairments may worsen the social and communicative problems of these persons. The aims of this study are to determine the prevalence of hearing impairment, to specify type and degree…
Manchaiah, Vinaya K C; Stephens, Dafydd; Andersson, Gerhard; Rönnberg, Jerker; Lunner, Thomas
2013-01-24
Hearing impairment is one of the most frequent chronic conditions. Persons with a hearing impairment (PHI) have various experiences during their 'journey' through hearing loss. In our previous studies we have developed a 'patient journey' model of PHI and their communication partners (CPs). We suggest this model could be useful in internet-based pre-fitting counseling of a person with hearing disability (PHD). A randomized controlled trial (RCT) with waiting list control (WLC) design will be used in this study. One hundred and fifty eight participants with self-reported hearing disability (that is, score > 20 in the Hearing Handicap Questionnaire (HHQ)) will be recruited to participate in this study. They will be assigned to one of two groups (79 participants in each group): (1) Information and counseling provision using the 'patient journey' model; and (2) WLC. They will participate in a 30 day (4 weeks) internet-based counseling program based on the 'patient journey' model. Various outcome measures which focuses on hearing disability, depression and anxiety, readiness to change and acceptance of hearing disability will be administered pre (one week before) and post (one week and six months after) intervention to evaluate the effectiveness of counseling. Internet-based counseling is being introduced as a viable option for audiological rehabilitation. We predict that the 'patient journey' model will have several advantages during counseling of a PHD. Such a program, if proven effective, could yield cost and time-efficient ways of managing hearing disability. ClinicalTrials.gov Protocol Registration System NCT01611129.
Improving regional universal newborn hearing screening programmes in Italy.
Molini, E; Cristi, M C; Lapenna, R; Calzolaro, L; Muzzi, E; Ciciriello, E; Della Volpe, A; Orzan, E; Ricci, G
2016-02-01
The Universal Newborn Hearing Screening (UNHS) programme aims at achieving early detection of hearing impairment. Subsequent diagnosis and intervention should follow promptly. Within the framework of the Ministry of Health project CCM 2013 "Preventing Communication Disorders: a Regional Program for early Identification, Intervention and Care of Hearing Impaired Children", the limitations and strengths of current UNHS programs in Italy have been analysed by a group of professionals working in tertiary centres involved in regional UNHS programmes, using SWOT analysis and a subsequent TOWS matrix. Coverage and lost-to-follow up rates are issues related to UNHS programmes. Recommendations to improve the effectiveness of the UNHS programme have been identified. The need for homogeneous policies, high-quality information and dissemination of knowledge for operators and families of hearing-impaired children emerged from the discussion. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale.
Strategic Planning to Improve EHDI Programs
ERIC Educational Resources Information Center
White, Karl R.; Blaiser, Kristina M.
2011-01-01
Because newborn hearing screening has become the standard of care in the United States, every state has established an early hearing detection and intervention (EHDI) program responsible for establishing, maintaining, and improving the system of services needed to serve children with hearing loss and their families. While significant developments…
Kuban, Karl C K; O'Shea, T Michael; Allred, Elizabeth N; Tager-Flusberg, Helen; Goldstein, Donald J; Leviton, Alan
2009-04-01
To test the hypothesis that children born preterm are more likely to screen positive on the M-CHAT for an autism spectrum disorder. We compared the M-CHAT positive rate of those with cerebral palsy, cognitive impairment, and vision and hearing impairments to those without such deficits. Relative to children who could walk, the odds for screening positive on the M-CHAT were increased 23-fold for those unable to sit or stand independently and more than 7-fold for those requiring assistance to walk. Compared with children without a diagnosis of cerebral palsy, those with quadriparesis were 13 times more likely to screen positive, and those with hemiparesis were 4 times more likely to screen positive. Children with major vision or hearing impairments were 8 times more likely to screen positive than those without such impairments. Relative to those with a Mental Development Index (MDI) of >70, the odds for screening positive were increased 13-fold for those with an MDI of <55 and more than 4-fold for those with an MDI of 55 to 69. Major motor, cognitive, visual, and hearing impairments appear to account for more than half of the positive M-CHAT screens in extremely low gestational age newborns. Even after those with such impairments were eliminated, 10% of children--nearly double the expected rate--screened positive.
An Introduction to the Outcomes of Children with Hearing Loss Study
Moeller, Mary Pat; Tomblin, J. Bruce
2015-01-01
The landscape of service provision for young children with hearing loss has shifted in recent years as a result of newborn hearing screening and the early provision of interventions, including hearing technologies. It is expected that early service provision will minimize or prevent linguistic delays that typically accompany untreated permanent childhood hearing loss. The post-newborn hearing screening era has seen a resurgence of interest in empirically examining the outcomes of children with hearing loss to determine if service innovations have resulted in expected improvements in children’s functioning. The Outcomes of Children with Hearing Loss (OCHL) project was among these recent research efforts, and this introductory article provides background in the form of literature review and theoretical discussion to support the goals of the study. The OCHL project was designed to examine the language and auditory outcomes of infants and preschool-aged children with permanent, bilateral, mild-to-severe hearing loss and to identify factors that moderate the relationship between hearing loss and longitudinal outcomes. We propose that children who are hard of hearing experience limitations in access to linguistic input, which lead to a decrease in uptake of language exposure and an overall reduction in linguistic experience. We explore this hypothesis in relation to three primary factors that are proposed to influence children’s access to linguistic input: aided audibility, duration and consistency of hearing aid (HA) use, and characteristics of caregiver input. PMID:26731159
Kimberling, William J; Hildebrand, Michael S; Shearer, A Eliot; Jensen, Maren L; Halder, Jennifer A; Trzupek, Karmen; Cohn, Edward S; Weleber, Richard G; Stone, Edwin M; Smith, Richard J H
2010-08-01
Usher syndrome is a major cause of genetic deafness and blindness. The hearing loss is usually congenital and the retinitis pigmentosa is progressive and first noticed in early childhood to the middle teenage years. Its frequency may be underestimated. Newly developed molecular technologies can detect the underlying gene mutation of this disorder early in life providing estimation of its prevalence in at risk pediatric populations and laying a foundation for its incorporation as an adjunct to newborn hearing screening programs. A total of 133 children from two deaf and hard of hearing pediatric populations were genotyped first for GJB2/6 and, if negative, then for Usher syndrome. Children were scored as positive if the test revealed > or =1 pathogenic mutations in any Usher gene. Fifteen children carried pathogenic mutations in one of the Usher genes; the number of deaf and hard of hearing children carrying Usher syndrome mutations was 15/133 (11.3%). The population prevalence was estimated to be 1/6000. Usher syndrome is more prevalent than has been reported before the genome project era. Early diagnosis of Usher syndrome has important positive implications for childhood safety, educational planning, genetic counseling, and treatment. The results demonstrate that DNA testing for Usher syndrome is feasible and may be a useful addition to newborn hearing screening programs.
Kimberling, William J.; Hildebrand, Michael S.; Shearer, A. Eliot; Jensen, Maren L.; Halder, Jennifer A.; Cohn, Edward S.; Weleber, Richard G.; Stone, Edwin M.; Smith, Richard J. H.
2011-01-01
Purpose Usher syndrome is a major cause of genetic deafblindness. The hearing loss is usually congenital and the retinitis pigmentosa is progressive and first noticed in early childhood to the middle teenage years. Its frequency may be underestimated. Newly developed molecular technologies can detect the underlying gene mutation of this disorder early in life providing estimation of its prevalence in at risk pediatric populations and laying a foundation for its incorporation as an adjunct to newborn hearing screening programs. Methods A total of 133 children from two deaf and hard of hearing pediatric populations were genotyped first for GJB2/6 and, if negative, then for Usher syndrome. Children were scored as positive if the test revealed ≥1 pathogenic mutations in any Usher gene. Results Fifteen children carried pathogenic mutations in one of the Usher genes; the number of deaf and hard of hearing children carrying Usher syndrome mutations was 15/133 (11.3%). The population prevalence was estimated to be 1/6000. Conclusion Usher syndrome is more prevalent than has been reported prior to the genome project era. Early diagnosis of Usher syndrome has important positive implications for childhood safety, educational planning, genetic counseling, and treatment. The results demonstrate that DNA testing for Usher syndrome is feasible and may be a useful addition to newborn hearing screening programs. PMID:20613545
Verhaert, N; Willems, M; Van Kerschaver, E; Desloovere, C
2008-05-01
Early intervention in hearing-impaired children may improve language outcomes and subsequent school and occupational performance. The objective of this study was to retrospectively analyze over 6 years the educational outcome and language development of a first cohort of children, detected by the Flemish universal newborn hearing screening (UNHS) program based on automated auditory brainstem response (AABR), with the oldest children being in primary school. We studied 229 hearing-impaired children from 1998 till 2003. The following variables were considered: the age during the school year 2005-2006, the degree of hearing loss, additional impairments including presence of intellectual disability, school placement and early intervention. Analysis showed that 85.4% of the children with moderate, severe or profound hearing loss and no additional disability, older than 5.5 years, reach mainstream education. Further detailed description was provided for the outcomes of children with uni- and bilateral cochlear implants. Overall results stress that 46% of all children with a cochlear implant obtain mainstream education. Of all cochlear implant (CI) children above 5.5 years, without additional handicaps, 78.9% of children attend primary mainstream school. Data on language development show that up to 45% of the children with unilateral cochlear implant and no additional disabilities had normal to slight delay on language development. These data are fulfilling the goals stated by the JCIH and the American Academy of Pediatrics (AAP) in 2000. The role and impact of additional handicaps is discussed. The importance of early hearing loss identification and hearing therapy for appropriate language development is highlighted. Finally our preliminary results on children with bilateral cochlear implants without additional handicaps present an improved language development in comparison to unilateral CI-children. A vast majority of the children detected by the UNHS program, with moderate, severe or profound hearing loss and no additional disability, older than 5.5 years, reach mainstream education. Additional disabilities have a major influence.
Perceived industrial deafness and hearing loss among people in a small Queensland rural community.
Jirojwong, Sansnee; Joubert, Darren; Anastasi, Stephen
2005-07-01
This paper aims to describe chronic diseases including hearing loss reported by people in a small rural community. It will present the results of audiometric screening among a group of people in this community and their self reported risk factors of hearing loss. Different risk factors experienced by men and women will be compared. Two surveys were conducted in a small Queensland rural community. The first survey gathered information relating to chronic diseases among 604 people using a telephone interview method. The second survey assessed the level of hearing among 64 people who presented themselves for audiometric screening, their history of exposure to loud noise and their previous use of hearing protective measures. A higher rate of "industrial deafness" was reported (110.75 per 1,000 population) than the 1995 National rate (95.2 per 1,000 population). Of 64 people who attended the audiometric assessment, 60 (93.8%) had some level of hearing loss using the 2000 International Standard of hearing level (ISO 7029: 2000) taking age and gender into account. However, 15 persons (23.4%) perceived that they had good hearing. When compared to ISO 7029: 2000 standard, men and women had a similar pattern of hearing loss. Compared to men, a lower percentage of women were exposed to different sources of loud noise and were less likely to use hearing protection devices.
Early Detection and Diagnosis of Hearing Impairment: A United Kingdom Perspective.
ERIC Educational Resources Information Center
Bamford, John M.; McSporran, Eileen
1993-01-01
The incidence of congenital hearing loss in the United Kingdom is noted, and the use of a universal behavioral hearing screen at the age of seven or eight months, implemented by Health Visitors, is described. Procedures involved in identification, diagnosis, and management are discussed. (JDD)
ERIC Educational Resources Information Center
Harris, Margaret; Terlektsi, Emmanouela; Kyle, Fiona E.
2017-01-01
Purpose: In this study, we compared the language and literacy of two cohorts of children with severe-profound hearing loss, recruited 10 years apart, to determine if outcomes had improved in line with the introduction of newborn hearing screening and access to improved hearing aid technology. Method: Forty-two children with deafness, aged 5-7…
ERIC Educational Resources Information Center
Hayes, Heather
2010-01-01
Developments in universal newborn hearing screening programs and assistive hearing technology have had considerable effects on the speech, language, and educational success of children who are deaf or hard of hearing. Several recent research studies of children who are deaf or hard of hearing and who use spoken language as their primary method of…
Servidoni, Alexandre Barbosa; Conterno, Lucieni de Oliveira
2018-01-01
Introduction Hearing losses inherent to the natural process of aging represent today a major public health issue, despite the little attention that their adequate care still receives. Early recognition and proper management of these shortcomings can significantly improve hearing, as well as the patient's general quality of life, reducing the overall impact of this important and prevalent condition of the aging process. Objective The aim of this research was to evaluate the accuracy of the Hearing Handicap Inventory for the Elderly - Screening Version (HHIE-S) in the diagnosis of hearing loss in the elderly when compared with the audiometric test. Methods Through a cross-sectional study, our target population was composed of 138 individuals, aged over 60 and with any otorhinolaryngological complaints, recruited at the Clinic of Otorhinolaryngology and Speech Therapy of the Faculdade de Medicina de Marília (Famema), in the city of Marília, SP, Brazil. Patients already in the process of auditory rehabilitation were excluded, as well as those who did not demonstrate the minimum level of oral understanding necessary to allow the interview. Results The prevalence of hearing loss according to the questionnaire was of 76.1%, while audiometry showed 79.7%. We found the diagnostic accuracy of the instrument to be of 86.2%, with a sensitivity of 89.1% and a specificity of 75.0%, regardless of gender. Conclusion Thereby, we conclude that the standardized questionnaire under rating is suitable for the screening of hearing loss in the elderly, given its high accuracy and user-friendly quality. PMID:29371892
Nurses with Undiagnosed Hearing Loss: Implications for Practice.
Spencer, Cara S; Pennington, Karen
2015-01-05
Hearing loss affects 36 million people in the United States of America, including 17% of the adult population. This suggests some nurses will have hearing losses that affect their communication skills and their ability to perform auscultation assessments, potentially compromising patient care and safety. In this article, the authors begin by reviewing the hearing process, describing various types of hearing loss, and discussing noise-induced hearing loss and noise levels in hospitals. Next, they consider the role of hearing in nursing practice, review resources for hearing-impaired nurses, identify the many costs associated with untreated hearing loss, and note nurses' responsibility for maintaining their hearing health. The authors conclude that nurses need to be aware of their risk for hearing loss and have their hearing screened every five years.
An Alternative to Impedance Screening: Unoccluded Frontal Bone Conduction Screening.
ERIC Educational Resources Information Center
Square, Regina; And Others
1985-01-01
A bone conduction hearing screening test using frontal bone oscillator placement was compared with pure-tone air-conduction screening and impedance audiometry with 114 preschoolers. Unoccluded frontal bone conduction testing produced screening results not significantly different from results obtained by impedance audiometry. (CL)!
Genetics of non syndromic hearing loss.
Venkatesh, M D; Moorchung, Nikhil; Puri, Bipin
2015-10-01
Non Syndromic Hearing Loss is an important cause for hearing loss. One in 1000 newborns have some hearing impairment. Over 400 genetic syndromes have been described. Non Syndromic Hearing Loss (NSHL) can be inherited in an Autosomal Dominant, Autosomal Recessive or a Sex Linked fashion. There are several reasons why genetic testing should be done in cases of NSHL, the main reasons being for genetic screening and for planning treatment. This review describes the genes involved in NSHL and the genetic mechanisms involved in the pathogenesis of the disease.
2013-01-01
Background Hearing impairment is one of the most frequent chronic conditions. Persons with a hearing impairment (PHI) have various experiences during their ‘journey’ through hearing loss. In our previous studies we have developed a ‘patient journey’ model of PHI and their communication partners (CPs). We suggest this model could be useful in internet-based pre-fitting counseling of a person with hearing disability (PHD). Methods/Design A randomized controlled trial (RCT) with waiting list control (WLC) design will be used in this study. One hundred and fifty eight participants with self-reported hearing disability (that is, score >20 in the Hearing Handicap Questionnaire (HHQ)) will be recruited to participate in this study. They will be assigned to one of two groups (79 participants in each group): (1) Information and counseling provision using the ‘patient journey’ model; and (2) WLC. They will participate in a 30 day (4 weeks) internet-based counseling program based on the ‘patient journey’ model. Various outcome measures which focuses on hearing disability, depression and anxiety, readiness to change and acceptance of hearing disability will be administered pre (one week before) and post (one week and six months after) intervention to evaluate the effectiveness of counseling. Discussion Internet-based counseling is being introduced as a viable option for audiological rehabilitation. We predict that the ‘patient journey’ model will have several advantages during counseling of a PHD. Such a program, if proven effective, could yield cost and time-efficient ways of managing hearing disability. Trial registration ClinicalTrials.gov Protocol Registration System NCT01611129. PMID:23347711
Code of Federal Regulations, 2010 CFR
2010-01-01
... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.9 Subpoenas..., records or other documentary or physical evidence for the purpose of the hearing, as the ALJ deems... least 10 business days before the scheduled hearing or deposition, unless the ALJ determines, for good...
[The model of aged-hearing monitoring under the hospital information system].
Bao, Xiao-lin; Xu, Hua; Sun, Qiang; Liu, Ji-hong; Guo, Jia-liang
2013-03-01
To study the oldly people's hearing screening and dynamic monitoring mode, and to discuss the new diseases and health management mode in current information network era. To establish the network connection between the hospital and the communities in the internet through the function expansion of the Hospital Information Systems and to realize "dual systems, double platforms" integrated management modes and establish the audiology workstation. The routine physical examination, pure tone hearing threshold tests and middle ear analysis were performed on four hundred and twenty elderly people from the fourteen communities every three months, and the changes of hearing and related symptoms were observed. Resources sharing was established between the hospital and these fourteen communities. Health records were established for all the aged people, the hearing screening lasted only half a day each time. Fourteen hearing loss cases were found during one year. A statistically significant difference (P < 0.01) were found, the ratio of hearing loss with diabetes, high blood pressure and other diseases were much higher than people without concomitant. The advantage of disease management mode under the Hospital Information System is convenient, the work efficiency and qualities are improved, which is worthy of popularizing.
PALUDETTI, G.; CONTI, G.; DI NARDO, W.; DE CORSO, E.; ROLESI, R.; PICCIOTTI, P.M.; FETONI, A.R.
2012-01-01
SUMMARY Hearing loss is one of the most common disabilities and has lifelong consequences for affected children and their families. Both conductive and sensorineural hearing loss (SNHL) may be caused by a wide variety of congenital and acquired factors. Its early detection, together with appropriate intervention, is critical to speech, language and cognitive development in hearing-impaired children. In the last two decades, the application of universal neonatal hearing screening has improved identification of hearing loss early in life and facilitates early intervention. Developments in molecular medicine, genetics and neuroscience have improved the aetiological classification of hearing loss. Once deafness is established, a systematic approach to determining the cause is best undertaken within a dedicated multidisciplinary setting. This review addresses the innovative evidences on aetiology and management of deafness in children, including universal neonatal screening, advances in genetic diagnosis and the contribution of neuroimaging. Finally, therapy remains a major challenge in management of paediatric SNHL. Current approaches are represented by hearing aids and cochlear implants. However, recent advances in basic medicine which are identifying the mechanisms of cochlear damage and defective genes causing deafness, may represent the basis for novel therapeutic targets including implantable devices, auditory brainstem implants and cell therapy. PMID:23349554
Software intelligent system for effective solutions for hearing impaired subjects.
S, Rajkumar; S, Muttan; V, Sapthagirivasan; V, Jaya; S S, Vignesh
2017-01-01
The anatomy and physiology of the ear is complex in nature, which makes it a challenge for audiologists to prescribe solutions for varied hearing-impaired subjects. There is a need to increase the satisfaction level of hearing-aid users by adopting better strategies that involve modern technological advancements. To design and develop a decision support Software Intelligent System (SIS) that performs audiological investigations to assess the degree of hearing loss and to suggest appropriate hearing-aid gain values. SIS is developed based on the study conducted in the Government General Hospital, Chennai, India, between 2013 and 2015. In the study period, audiological investigations were performed on 368 subjects, using the clinical audiometer (Inventis-Piano, Italy) and the SIS. Gain suggestions were recommended for hearing-aid users (Siemens Intuis life & Intuis-SP) using standard prescriptive procedures, alterations made by the audiologists, and by the SIS. It was developed with artificial neural network-based gain predictions. Of the tested subjects, 256 were identified as hearing-impaired. The calculated sensitivity, specificity and accuracy of the computerised audiometer incorporated in the SIS are 93%, 85% and 90% respectively. Furthermore, 86% of the hearing-impaired subjects were satisfied during their first hearing-aid trial with the gain recommendations from SIS. The findings suggest that the proposed SIS could be used to perform audiological screening tests and to recommend appropriate hearing-aid gain values to the hearing-impaired subjects. This could eventually be helpful for audiologists in the areas where routine mass audiological screening and fast hearing-aid solution is required. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Mild and Unilateral Hearing Loss: Implications for Early Intervention
ERIC Educational Resources Information Center
Holstrum, W. June; Biernath, Krista; McKay, Sarah; Ross, Danielle S.
2009-01-01
Newborn hearing screening has become a standard practice in most birthing hospitals in the United States. Historically, the primary target for the identification of hearing loss has been infants with permanent bilateral loss of moderate degree or greater (i.e., greater than 40 dB). However, research indicates that without early identification and…
Early Hearing Detection and Intervention in Developing Countries: Current Status and Prospects
ERIC Educational Resources Information Center
Olusanya, Bolajoko O.
2006-01-01
Infant hearing screening is emerging rapidly as a silent global revolution for the early detection of children with congenital or early onset hearing loss to ensure timely enrollment in family-oriented intervention programs for the development of spoken language. This article examines the overriding and interrelated scientific, ethical and…
Genetic basis of hearing loss in Spanish, Hispanic and Latino populations.
Mittal, Rahul; Patel, Amit P; Nguyen, Desiree; Pan, Debbie R; Jhaveri, Vasanti M; Rudman, Jason R; Dharmaraja, Arjuna; Yan, Denise; Feng, Yong; Chapagain, Prem; Lee, David J; Blanton, Susan H; Liu, Xue Zhong
2018-03-20
Hearing loss (HL) is the most common neurosensory disorder affecting humans. The screening, prevention and treatment of HL require a better understanding of the underlying molecular mechanisms. Genetic predisposition is one of the most common factors that leads to HL. Most HL studies include few Spanish, Hispanic and Latino participants, leaving a critical gap in our understanding about the prevalence, impact, unmet health care needs, and genetic factors associated with hearing impairment among Spanish, Hispanic and Latino populations. The few studies which have been performed show that the gene variants commonly associated with HL in non-Spanish and non-Hispanic populations are infrequently responsible for hearing impairment in Spanish as well as Hispanic and Latino populations (hereafter referred to as Hispanic). To design effective screening tools to detect HL in Spanish and Hispanic populations, studies must be conducted to determine the gene variants that are most commonly associated with hearing impairment in this racial/ethnic group. In this review article, we summarize gene variants and loci associated with HL in Spanish and Hispanic populations. Identifying new genetic variants associated with HL in Spanish and Hispanic populations will pave the way to develop effective screening tools and therapeutic strategies for HL. Copyright © 2018 Elsevier B.V. All rights reserved.
Purpose of Newborn Hearing Screening
... services, babies will have trouble with speech and language development. For some babies, early intervention services may include ... baby will have the best chance for normal language development if any hearing loss is discovered and treatment ...
Hearing Loss in Children: Screening and Diagnosis
... and Statistical Hub (DASH) Articles & Key Findings Research & Tracking EHDI Funded Projects EHDI FOA 1701 Funding Map ... audiologist can do to find out if a person has a hearing loss, how much of a ...
Hearing impairment and language delay in infants: Diagnostics and genetics
Lang-Roth, Ruth
2014-01-01
This overview study provides information on important phoniatric and audiological aspects of early childhood hearing and language development with the aim of presenting diagnostic and therapeutic approaches. The article first addresses the universal newborn hearing screening that has been implemented in Germany for all infants since January 2009. The process of newborn hearing screening from the maternity ward to confirmation diagnostics is presented in accordance with a decision by the Federal Joint Committee (G-BA). The second topic is pediatric audiology diagnostics. Following confirmation of a permanent early childhood hearing disorder, the search for the cause plays an important role. Hereditary hearing disorders and intrauterine cytomegalovirus (CMV) infection, probably the most common cause of an acquired hearing disorder, are discussed and compared with the most common temporary hearing disorder, otitis media with effusion, which in some cases is severe enough to be relevant for hearing and language development and therefore requires treatment. The third topic covered in this article is speech and language development in the first 3 years of life, which is known today to be crucial for later language development and learning to read and write. There is a short overview and introduction to modern terminology, followed by the abnormalities and diagnostics of early speech and language development. Only some aspects of early hearing and language development are addressed here. Important areas such as the indication for a cochlear implant in the first year of life or because of unilateral deafness are not included due to their complexity. PMID:25587365
Results of an early hearing detection program.
Borkoski Barreiro, Silvia A; Falcón González, Juan C; Bueno Yanes, Jorge; Pérez Bermúdez, José L; López Cano, Zoraida; Ramos Macías, Ángel
2013-01-01
Neonatal hearing loss is a public health problem that meets the requirements for submission to universal screening. Our objective was to analyse the results of the early hearing detection and intervention program implemented at our centre between January 2007 and December 2010. We studied 26,717 newborns during the period mentioned, using transient otoacoustic emissions (TOAEs) for the screening. The diagnostic phase was carried out at the hearing loss department. In our area, there were 27,935 births between January 2007 and December 2010. The screening was performed on 26,717 children. Of these, 24,173 had positive TOAEs, 1,040 had no TOAEs and 1,504 presented TOAEs in 1 ear with absence of TOAEs in the contralateral ear. Risk factors associated with hearing loss were found in 4,674 infants. In a second phase of the program, TOAEs were given to 5,156 children, of whom 4,626 had positive otoacoustic emissions in both ears, 323 had no TOAEs in 1 ear and 207 failed this second phase. Of all children studied, 3.8% were referred to auditory brainstem response (ABR) testing and 26 children entered the cochlear implant program. The program reached coverage of 95.64%. The early hearing detection and intervention program at our hospital is suitable for our environment, reaching 95.64% of coverage. We consider the relationship between effectiveness and efficiency to be positive. Copyright © 2012 Elsevier España, S.L. All rights reserved.
How Are My Newborn's Screening Results Used?
... Pinterest Email Print How are my newborn’s screening results used? In most cases, parents don't hear ... for a particular condition(s). 1 Out of Range Results If the screening detects one or more conditions, ...
Whitlon, Donna S
2017-06-01
In the United States there are, at present, no drugs that are specifically FDA approved to treat hearing loss. Although several clinical trials are ongoing, including one testing D-methionine that is supported by the US Army, none of these trials directly address the effect of noise exposure on cochlear spiral ganglion neurons. We recently published the first report of a systematic chemical compound screen using primary, mammalian spiral ganglion cultures in which we were able to detect a compound and others in its class that increased neurite elongation, a critical step in restoring cochlear synapses after noise induced hearing loss. Here we discuss the issues, both pro and con, that influenced the development of our approach. These considerations may be useful for future compound screens that target the same or other attributes of cochlear spiral ganglion neurons. Copyright © 2016 Elsevier B.V. All rights reserved.
Claes, Annes J; Mertens, Griet; Gilles, Annick; Hofkens-Van den Brandt, Anouk; Fransen, Erik; Van Rompaey, Vincent; Van de Heyning, Paul
2016-01-01
Background: Currently, an independent relationship between hearing loss and cognitive decline in older adults is suggested by large prospective studies. In general, cochlear implants improve hearing and the quality of life in severely to profoundly hearing impaired older persons. However, little is known about the effects of cochlear implantation on the cognitive evolution in this population. Aim of the study: The primary goal of this prospective, longitudinal cohort study is to explore the cognitive profile of severely to profoundly postlingually hearing impaired subjects before and after cochlear implantation. In addition, the current study aims to investigate the relationship between the cognitive function, audiometric performances, quality of life, and self-reliance in these patients. Methods: Twenty-five patients aged 55 or older, scheduled for cochlear implantation, will be enrolled in the study. They will be examined prior to implantation, at 6 and 12 months after implantation and annually thereafter. The test battery consists of (1) a cognitive examination, using the Repeatable Battery for the Assessment of Neuropsychological Status adapted for Hearing impaired persons (RBANS-H), (2) an audiological examination, including unaided and aided pure tone audiometry, speech audiometry in quiet and speech audiometry in noise, (3) the administration of four questionnaires evaluating quality of life and subjective hearing benefit and (4) a semi-structured interview about the self-reliance of the participant. Discussion: Up until now only one study has been conducted on this topic, focusing on the short-term effects of cochlear implantation on cognition in older adults. The present study is the first study to apply a comprehensive neuropsychological assessment adapted for severely to profoundly hearing impaired subjects in order to investigate the cognitive capabilities before and after cochlear implantation. Trial registration: The present protocol is retrospectively registered at Clinical Trials (ClinicalTrials.gov) on June 9th, 2016. The first participant was enrolled on June 22nd, 2015. The protocol identifier is NCT02794350.
Claes, Annes J.; Mertens, Griet; Gilles, Annick; Hofkens-Van den Brandt, Anouk; Fransen, Erik; Van Rompaey, Vincent; Van de Heyning, Paul
2016-01-01
Background: Currently, an independent relationship between hearing loss and cognitive decline in older adults is suggested by large prospective studies. In general, cochlear implants improve hearing and the quality of life in severely to profoundly hearing impaired older persons. However, little is known about the effects of cochlear implantation on the cognitive evolution in this population. Aim of the study: The primary goal of this prospective, longitudinal cohort study is to explore the cognitive profile of severely to profoundly postlingually hearing impaired subjects before and after cochlear implantation. In addition, the current study aims to investigate the relationship between the cognitive function, audiometric performances, quality of life, and self-reliance in these patients. Methods: Twenty-five patients aged 55 or older, scheduled for cochlear implantation, will be enrolled in the study. They will be examined prior to implantation, at 6 and 12 months after implantation and annually thereafter. The test battery consists of (1) a cognitive examination, using the Repeatable Battery for the Assessment of Neuropsychological Status adapted for Hearing impaired persons (RBANS-H), (2) an audiological examination, including unaided and aided pure tone audiometry, speech audiometry in quiet and speech audiometry in noise, (3) the administration of four questionnaires evaluating quality of life and subjective hearing benefit and (4) a semi-structured interview about the self-reliance of the participant. Discussion: Up until now only one study has been conducted on this topic, focusing on the short-term effects of cochlear implantation on cognition in older adults. The present study is the first study to apply a comprehensive neuropsychological assessment adapted for severely to profoundly hearing impaired subjects in order to investigate the cognitive capabilities before and after cochlear implantation. Trial registration: The present protocol is retrospectively registered at Clinical Trials (ClinicalTrials.gov) on June 9th, 2016. The first participant was enrolled on June 22nd, 2015. The protocol identifier is NCT02794350. PMID:27895549
Paschoal, Monique Ramos; Cavalcanti, Hannalice Gottschalck; Ferreira, Maria Ângela Fernandes
2017-11-01
This article seeks to establish the coverage of neonatal hearing screening in Brazil between January 2008 and June 2015. It is an ecological study that uses the country, through the Urban Articulation Regions, as a base. To calculate the screening coverage percentage, the Live Births Information System, the Outpatient Information System and the Beneficiaries of the National Supplementary Health Agency Information System were used. An exploratory analysis of maps and spatial statistical analysis was conducted using TerraView 4.2.2 software. The coverage of neonatal hearing screening saw an increase of 9.3% to 37.2% during the study period. In 2008-2009 it was observed that the percentage of coverage ranged from 0% to 79.92%, but most areas received coverage from 0% to 20%, though in 2014-2015 coverage ranged from 0% to 171.77%, and there was a visible increase in the percentage of coverage in the country, mainly in the Southern Region. The screening coverage has increased over time, but is still low with an uneven distribution in the territory, which may be explained by local laws and policies and by the existence of different types of auditory health service in the country.
Cannon, Michael J.; Griffiths, Paul D.; Aston, Van; Rawlinson, William D.
2015-01-01
SUMMARY Congenital CMV infection is a leading cause of childhood disability. Many children born with congenital CMV infection are asymptomatic or have nonspecific symptoms and therefore are typically not diagnosed. A strategy of newborn CMV screening could allow for early detection and intervention to improve clinical outcomes. Interventions might include antiviral drugs or nonpharmaceutical therapies such as speech-language therapy or cochlear implants. Using published data from developed countries, we analyzed existing evidence of potential benefit that could result from newborn CMV screening. We first estimated the numbers of children with the most important CMV-related disabilities (i.e. hearing loss, cognitive deficit, and vision impairment), including the age at which the disabilities occur. Then, for each of the disabilities, we examined the existing evidence for the effectiveness of various interventions. We concluded that there is good evidence of potential benefit from nonpharmaceutical interventions for children with delayed hearing loss that occurs by 9 months of age. Similarly, we concluded that there is fair evidence of potential benefit from antiviral therapy for children with hearing loss at birth and from nonpharmaceutical interventions for children with delayed hearing loss occurring between 9 and 24 months of age and for children with CMV-related cognitive deficits. We found poor evidence of potential benefit for children with delayed hearing loss occurring after 24 months of age and for children with vision impairment. Overall, we estimated that in the United States, several thousand children with congenital CMV could benefit each year from newborn CMV screening, early detection, and interventions. Copyright © 2014 John Wiley & Sons, Ltd. PMID:24760655
Fletcher, Kyle T; Horrell, Erin M Wolf; Ayugi, John; Irungu, Catherine; Muthoka, Maria; Creel, Liza M; Lester, Cathy; Bush, Matthew L
2018-06-15
The purpose of this study was to examine the literature regarding the natural history and rehabilitative outcomes of sensorineural hearing loss from congenital cytomegalovirus infections. A systematic search was performed in PubMed, PsychINFO, CINAHL, and Web of Science to identify peer-reviewed research. Eligible studies were those containing original peer-reviewed research in English addressing either the natural history or rehabilitative outcomes of sensorineural hearing loss (SNHL) in congenital cytomegalovirus (cCMV). Two investigators independently reviewed all articles and extracted data. Bias was assessed using the Cochrane Collaboration's tool and the Newcastle-Ottawa Assessment Scale. Thirty-six articles were reviewed. Universal screening identifies 0.2 to 1% of newborns with cCMV infection. SNHL ranged from 8 to 32% of infants and was more prevalent in symptomatic versus asymptomatic cases. Nine to 68% of hearing loss occurs in a late or delayed fashion. In 7 to 71% of cases hearing loss is progressive. Cochlear implantation (CI) is a viable option for patients with cCMV associated hearing loss and leads to improvements in hearing and language. There is limited literature comparing rehabilitation outcomes in cCMV and non-cCMV CI recipients. Late onset and progressive hearing loss is seen in children who develop hearing loss from cCMV. Frequent audiologic follow-up is necessary considering the natural history of cCMV hearing loss. Universal screening should be pursued due to the number of asymptomatic children, at birth, who develop late onset/delayed hearing loss. CI is an effective means of improving speech and language in this population.
ERIC Educational Resources Information Center
Porter, Ann; Edirippulige, Sisira
2007-01-01
Parents whose children are diagnosed in an infant screening program are required to make some difficult choices about the management of the hearing loss at a time when they are emotionally vulnerable. They are required to evaluate information and outcomes regarding issues such as technology for hearing impairment, communication options, education,…
ERIC Educational Resources Information Center
Grandpierre, Viviane; Fitzpatrick, Elizabeth M.; Na, Eunjung; Mendonca, Oreen
2018-01-01
Following the establishment of newborn hearing screening programs, age of identification and length of time before receiving interventions has been reduced for children, including those with milder degrees of hearing loss who were previously not identified until school age. This population of early-identified children requires new support programs…
First Information Parents Receive after UNHS Detection of Their Baby's Hearing Loss
ERIC Educational Resources Information Center
Matthijs, Liesbeth; Loots, Gerrit; Mouvet, Kimberley; Van Herreweghe, Mieke; Hardonk, Stefan; Van Hove, Geert; Van Puyvelde, Martine; Leigh, Greg
2012-01-01
The first information parents receive after referral through Universal Newborn Hearing Screening (UNHS) has significant consequences for later care-related decisions they take and thus for the future of the child with a hearing loss. In this study, 11 interviews were conducted with a representative sample of Flemish service providers to discover…
Age of diagnosis of congenital hearing loss: Private v. public healthcare sector.
Butler, I R T; Ceronio, D; Swart, T; Joubert, G
2015-11-01
The age of diagnosis of congenital hearing loss is one of the most important determinants of communication outcome. A previous study by the lead author had evaluated the performance of the public health services in Bloemfontein, South Africa (SA), in this regard. This study aimed to examine whether the private health services in the same city were any better. To determine whether the age of diagnosis of congenital hearing loss (CHL) in children seen in the private healthcare sector in Bloemfontein, Free State Province, SA, was lower than that in the public healthcare system in the same city. A comparative study design was utilised and a retrospective database review conducted. Data obtained from this study in the private healthcare sector were compared with data from a previous study in the public healthcare sector using the same study design. Forty-eight children aged <6 years with disabling hearing impairment (DHI) were identified in the private healthcare sector during the study period; 33/47 (70.2%) did not undergo hearing screening at birth. The median age of diagnosis of DHI in the private healthcare sector was 2.24 years, and this was statistically significantly lower than the median age of diagnosis of 3.71 years in the public healthcare sector (p<0.0001; 95% confidence interval (CI) 0.99-2.0). The median age of diagnosis of congenital hearing loss (CHL) in the private healthcare sector was 3.01 years in children who were not screened at birth, and 1.25 years in those who were screened at birth. This difference was statistically significant (p<0.01; 95% CI 0.72-2.47). We also compared the median age of diagnosis of CHL in children from the private healthcare sector who were not screened at birth (median 3.01 years) with that in children in the public healthcare sector (median 3.71 years). This difference was statistically significant (p<0.01; 95% CI 0.41-1.56). Children in the Free State are diagnosed with CHL at a younger age in the private healthcare sector than in the public healthcare sector. With the social and economic benefits of early intervention in cases of DHI well established internationally, SA healthcare providers in both the public and private sectors need to develop screening, diagnostic and (re)habilitation services for children with hearing impairment.
What's New with Newborn Screening
ERIC Educational Resources Information Center
Exceptional Parent, 2008
2008-01-01
Newborn screening is the process of testing and screening newborns shortly after birth for certain, potentially dangerous, conditions and/or impairments--conditions that include everything from inborn errors of metabolism and other genetic disorders to hearing impairment. Early detection through newborn screening is paramount, often allowing the…
Saliba, Joe; Al-Reefi, Mahmoud; Carriere, Junie S; Verma, Neil; Provencal, Christiane; Rappaport, Jamie M
2017-04-01
Objectives (1) To compare the accuracy of 2 previously validated mobile-based hearing tests in determining pure tone thresholds and screening for hearing loss. (2) To determine the accuracy of mobile audiometry in noisy environments through noise reduction strategies. Study Design Prospective clinical study. Setting Tertiary hospital. Subjects and Methods Thirty-three adults with or without hearing loss were tested (mean age, 49.7 years; women, 42.4%). Air conduction thresholds measured as pure tone average and at individual frequencies were assessed by conventional audiogram and by 2 audiometric applications (consumer and professional) on a tablet device. Mobile audiometry was performed in a quiet sound booth and in a noisy sound booth (50 dB of background noise) through active and passive noise reduction strategies. Results On average, 91.1% (95% confidence interval [95% CI], 89.1%-93.2%) and 95.8% (95% CI, 93.5%-97.1%) of the threshold values obtained in a quiet sound booth with the consumer and professional applications, respectively, were within 10 dB of the corresponding audiogram thresholds, as compared with 86.5% (95% CI, 82.6%-88.5%) and 91.3% (95% CI, 88.5%-92.8%) in a noisy sound booth through noise cancellation. When screening for at least moderate hearing loss (pure tone average >40 dB HL), the consumer application showed a sensitivity and specificity of 87.5% and 95.9%, respectively, and the professional application, 100% and 95.9%. Overall, patients preferred mobile audiometry over conventional audiograms. Conclusion Mobile audiometry can correctly estimate pure tone thresholds and screen for moderate hearing loss. Noise reduction strategies in mobile audiometry provide a portable effective solution for hearing assessments outside clinical settings.
Simplified risk assessment of noise induced hearing loss by means of 2 spreadsheet models.
Lie, Arve; Engdahl, Bo; Tambs, Kristian
2016-11-18
The objective of this study has been to test 2 spreadsheet models to compare the observed with the expected hearing loss for a Norwegian reference population. The prevalence rates of the Norwegian and the National Institute for Occupational Safety and Health (NIOSH) definitions of hearing outcomes were calculated in terms of sex and age, 20-64 years old, for a screened (with no occupational noise exposure) (N = 18 858) and unscreened (N = 38 333) Norwegian reference population from the Nord-Trøndelag Hearing Loss Study (NTHLS). Based on the prevalence rates, 2 different spreadsheet models were constructed in order to compare the prevalence rates of various groups of workers with the expected rates. The spreadsheets were then tested on 10 different occupational groups with varying degrees of hearing loss as compared to a reference population. Hearing of office workers, train drivers, conductors and teachers differed little from the screened reference values based on the Norwegian and the NIOSH criterion. The construction workers, miners, farmers and military had an impaired hearing and railway maintenance workers and bus drivers had a mildly impaired hearing. The spreadsheet models give a valid assessment of the hearing loss. The use of spreadsheet models to compare hearing in occupational groups with that of a reference population is a simple and quick method. The results are in line with comparable hearing thresholds, and allow for significance testing. The method is believed to be useful for occupational health services in the assessment of risk of noise induced hearing loss (NIHL) and the preventive potential in groups of noise-exposed workers. Int J Occup Med Environ Health 2016;29(6):991-999. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Social inequalities in pure-tone hearing assessed using occupational stratification schemes.
von Gablenz, Petra; Holube, Inga
2017-07-01
The objective of this study is to analyse the performance of two occupational stratification approaches and the impact of social position on adult hearing. The prevalence of hearing impairment, pure-tone averages (PTA) and prevalence ratios (PR) for relative hearing loss, which focuses on the position of one's PTA in the age- and gender-specific distribution, were compared in groups defined by ISCO Skill Level and the International Socio-Economic Index (ISEI). About 1571 subjects aged 30-89, including 677 highly screened adults, from the cross-sectional study HÖRSTAT. ISCO Skill Level and ISEI yielded qualitatively the same results. The prevalence difference between the socially least and most advantaged group ranges between 10 and 16%, varying with the scheme applied. Low- and high-frequency PTA and PR for relative hearing loss confirm the gradient. Screening reduced, but did not negate the social differences. The prevalence difference dropped to 6-7% in the otologically normal subsample. Social groups defined by hierarchical, occupational measures differ in their pure-tone hearing, even if the main risk factors are controlled for. This underlines the need for population-based sampling, the relevance of reporting the study group's social composition and the importance of advancing the discussion on appropriate social measures in hearing research.
Firefighter hearing health: an informatics approach to screening, measurement, and research.
Hong, OiSaeng; Monsen, Karen A; Kerr, Madeleine J; Chin, Dal Lae; Lytton, Amy B; Martin, Karen S
2012-10-01
The purpose of this study was to evaluate the use of a standardized interface terminology, the Omaha System, with respect to noise-induced hearing loss (NIHL). A descriptive, correlational design was employed for this secondary analysis with the data from an ongoing hearing protection intervention study. A total of 346 firefighters were included. First, an evidence-based standardized care plan (EB-SCP) for hearing screening was developed and validated by clinical experts. Second, occupational health records were used to compute Omaha System Knowledge, Behavior, and Status outcomes. Third, research data were mapped to Omaha System rating scales. For Knowledge, the mean score was close to 'adequate' (3.7). For Behavior, the mean score was close to 'rarely appropriate' (2.2). For Status, the mean score was close to 'minimal sign/symptom' (4.4). Significant positive relationships were found between Knowledge and Behavior (Spearman's rho =.13, p =.01), and between Behavior and hearing Status (Spearman's rho =.12, p =.02). Findings support the validity of the new Knowledge, Behavior, and hearing Status. Informatics methods such as the standardized NIHL EB-SCP and outcome data sets will create opportunities for clinical decision support and data exchange across various health care settings, thus supporting population-based hearing health assessments and outcomes.
Punch, Simone; Van Dun, Bram; King, Alison; Carter, Lyndal; Pearce, Wendy
2016-01-01
This article presents the clinical protocol that is currently being used within Australian Hearing for infant hearing aid evaluation using cortical auditory evoked potentials (CAEPs). CAEP testing is performed in the free field at two stimulus levels (65 dB sound pressure level [SPL], followed by 55 or 75 dB SPL) using three brief frequency-distinct speech sounds /m/, /ɡ/, and /t/, within a standard audiological appointment of up to 90 minutes. CAEP results are used to check or guide modifications of hearing aid fittings or to confirm unaided hearing capability. A retrospective review of 83 client files evaluated whether clinical practice aligned with the clinical protocol. It showed that most children could be assessed as part of their initial fitting program when they were identified as a priority for CAEP testing. Aided CAEPs were most commonly assessed within 8 weeks of the fitting. A survey of 32 pediatric audiologists provided information about their perception of cortical testing at Australian Hearing. The results indicated that clinical CAEP testing influenced audiologists' approach to rehabilitation and was well received by parents and that they were satisfied with the technique. Three case studies were selected to illustrate how CAEP testing can be used in a clinical environment. Overall, CAEP testing has been effectively integrated into the infant fitting program. PMID:27587921
A Whole New World: Technology and Its Impact on Students Who Are Deaf or Hard-of-Hearing
ERIC Educational Resources Information Center
Miller, Kevin
2015-01-01
In this article, the author describes technology used with children or students who are deaf or hard-of-hearing. Specifically, three technological developments are highlighted: cochlear implants, universal newborn infant hearing screening, and telepractice. The positive impact of each type of technology on students who are deaf or hard-of-hearing…
ERIC Educational Resources Information Center
Bozzay, Melanie L.; O'Leary, Kimberly N.; De Nadai, Alessandro S.; Gryglewicz, Kim; Romero, Gabriela; Karver, Marc S.
2017-01-01
The present study examined differences in symptom presentation in screening for pediatric depression via evaluation of the Patient Health Questionnaire-9 (PHQ-9). In particular, we examined whether PHQ-9 items function differentially among deaf and hard-of-hearing (DHH; n = 75) and hearing (n = 75) youth based on participants recruited from crisis…
Dement, John; Ringen, Knut; Welch, Laura; Bingham, Eula; Quinn, Patricia
2005-11-01
Medical screening programs at three Departments of Energy (DOE) nuclear weapons facilities (Hanford Nuclear Reservation, Oak Ridge, and the Savannah River Site) have included audiometric testing since approximately 1996. This report summarizes hearing evaluations through March 31, 2003. Occupational examinations included a medical history, limited physical examination, and tests for medical effects from specific hazards, including audiometric testing. Hearing thresholds by frequency for DOE workers were compared to age-standardized thresholds among an external comparison population of industrial workers with noise exposures <80 dBA. Multivariate analyses were used to explore the risk of hearing impairment by duration of construction trade work and self-reported noise exposure, while controlling for potential confounders such as age, race, sex, smoking, elevated serum cholesterol, hypertension, solvent exposures, and recreational noise exposures. Hearing thresholds among DOE workers were much higher than observed in a comparison population of industrial workers with low noise exposures. Overall, 59.7% of workers examined were found to have material hearing impairment by NIOSH criteria. Age, duration of construction work, smoking, and self-reported noise exposure increased the risk of hearing loss. The risk of material hearing impairment was significantly elevated for construction trade workers compared to the external comparison population (odds-ratio = 1.6, 95% CI = 1.3-2.1) and increased with the duration of trade work. These medical screening programs confirm worker concerns about risks for hearing loss and the need for hearing conservation programs for construction workers, with emphasis on the prevention of noise exposures.
Zokoll, Melanie A; Wagener, Kirsten C; Brand, Thomas; Buschermöhle, Michael; Kollmeier, Birger
2012-09-01
A review is given of internationally comparable speech-in-noise tests for hearing screening purposes that were part of the European HearCom project. This report describes the development, optimization, and evaluation of such tests for headphone and telephone presentation, using the example of the German digit triplet test. In order to achieve the highest possible comparability, language- and speaker-dependent factors in speech intelligibility should be compensated for. The tests comprise spoken numbers in background noise and estimate the speech reception threshold (SRT), i.e. the signal-to-noise ratio (SNR) yielding 50% speech intelligibility. The respective reference speech intelligibility functions for headphone and telephone presentation of the German version for 15 and 10 normal-hearing listeners are described by a SRT of -9.3 ± 0.2 and -6.5 ± 0.4 dB SNR, and slopes of 19.6 and 17.9%/dB, respectively. Reference speech intelligibility functions of all digit triplet tests optimized within the HearCom project allow for investigation of the comparability due to language specificities. The optimization criteria established here should be used for similar screening tests in other languages.
Predicting speech intelligibility in noise for hearing-critical jobs
NASA Astrophysics Data System (ADS)
Soli, Sigfrid D.; Laroche, Chantal; Giguere, Christian
2003-10-01
Many jobs require auditory abilities such as speech communication, sound localization, and sound detection. An employee for whom these abilities are impaired may constitute a safety risk for himself or herself, for fellow workers, and possibly for the general public. A number of methods have been used to predict these abilities from diagnostic measures of hearing (e.g., the pure-tone audiogram); however, these methods have not proved to be sufficiently accurate for predicting performance in the noise environments where hearing-critical jobs are performed. We have taken an alternative and potentially more accurate approach. A direct measure of speech intelligibility in noise, the Hearing in Noise Test (HINT), is instead used to screen individuals. The screening criteria are validated by establishing the empirical relationship between the HINT score and the auditory abilities of the individual, as measured in laboratory recreations of real-world workplace noise environments. The psychometric properties of the HINT enable screening of individuals with an acceptable amount of error. In this presentation, we will describe the predictive model and report the results of field measurements and laboratory studies used to provide empirical validation of the model. [Work supported by Fisheries and Oceans Canada.
Salina, Husain; Abdullah, Asma; Mukari, Siti Zamratol Mai-sarah; Azmi, Mohd Tamil
2010-04-01
Transient-evoked otoacoustic emission (TEOAE) is a well-established screening tool for universal newborn hearing screening. The aims of this study are to measure the effects of background noise on recording of TEOAE and the duration required to complete the test at various noise levels. This study is a prospective study from June 2006 until May 2007. The study population were newborns from postnatal wards who were delivered at term pregnancy. Newborns who were more than 8-h old and passed a hearing screening testing using screening auditory brainstem response (SABRe) were further tested with TEOAE in four different test environments [isolation room in the ward during non-peak hour (E1), isolation room in the ward during peak hour (E2), maternal bedside in the ward during non-peak hour (E3) and maternal bedside in the ward during peak hour (E4)]. This study showed that test environment significantly influenced the time required to complete testing in both ears with F [534.23] = 0.945; P < 0.001 on the right ear and F [636.54] = 0.954; P < 0.001 on the left. Our study revealed that TEOAE testing was efficient in defining the presence of normal hearing in our postnatal wards at maternal bedside during non-peak hour with a specificity of 96.8%. Our study concludes that background noise levels for acceptable and accurate TEOAE recording in newborns should not exceed 65 dB A. In addition, when using TEOAE assessment in noisy environments, the time taken to obtain accurate results will greatly increase.
Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry
Grysiński, Tomasz; Kręcicki, Tomasz
2018-01-01
Background Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. Objective This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Methods Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. Results A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. Conclusions The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. PMID:29321124
Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry.
Masalski, Marcin; Grysiński, Tomasz; Kręcicki, Tomasz
2018-01-10
Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headphones, the reference sound level can be calculated once for all devices of the same model. This study aimed to compare the hearing threshold measured by a mobile device that was calibrated using a model-specific, biologically determined reference sound level with the hearing threshold obtained in pure-tone audiometry. Trial participants were recruited offline using face-to-face prompting from among Otolaryngology Clinic patients, who own Android-based mobile devices with bundled headphones. The hearing threshold was obtained on a mobile device by means of an open access app, Hearing Test, with incorporated model-specific reference sound levels. These reference sound levels were previously determined in uncontrolled conditions in relation to the hearing threshold of normal-hearing persons. An audiologist-assisted self-measurement was conducted by the participants in a sound booth, and it involved determining the lowest audible sound generated by the device within the frequency range of 250 Hz to 8 kHz. The results were compared with pure-tone audiometry. A total of 70 subjects, 34 men and 36 women, aged 18-71 years (mean 36, standard deviation [SD] 11) participated in the trial. The hearing threshold obtained on mobile devices was significantly different from the one determined by pure-tone audiometry with a mean difference of 2.6 dB (95% CI 2.0-3.1) and SD of 8.3 dB (95% CI 7.9-8.7). The number of differences not greater than 10 dB reached 89% (95% CI 88-91), whereas the mean absolute difference was obtained at 6.5 dB (95% CI 6.2-6.9). Sensitivity and specificity for a mobile-based screening method were calculated at 98% (95% CI 93-100.0) and 79% (95% CI 71-87), respectively. The method of hearing self-test carried out on mobile devices with bundled headphones demonstrates high compatibility with pure-tone audiometry, which confirms its potential application in hearing monitoring, screening tests, or epidemiological examinations on a large scale. ©Marcin Masalski, Tomasz Grysiński, Tomasz Kręcicki. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 10.01.2018.
A small molecule mitigates hearing loss in a mouse model of Usher syndrome III.
Alagramam, Kumar N; Gopal, Suhasini R; Geng, Ruishuang; Chen, Daniel H-C; Nemet, Ina; Lee, Richard; Tian, Guilian; Miyagi, Masaru; Malagu, Karine F; Lock, Christopher J; Esmieu, William R K; Owens, Andrew P; Lindsay, Nicola A; Ouwehand, Krista; Albertus, Faywell; Fischer, David F; Bürli, Roland W; MacLeod, Angus M; Harte, William E; Palczewski, Krzysztof; Imanishi, Yoshikazu
2016-06-01
Usher syndrome type III (USH3), characterized by progressive deafness, variable balance disorder and blindness, is caused by destabilizing mutations in the gene encoding the clarin-1 (CLRN1) protein. Here we report a new strategy to mitigate hearing loss associated with a common USH3 mutation CLRN1(N48K) that involves cell-based high-throughput screening of small molecules capable of stabilizing CLRN1(N48K), followed by a secondary screening to eliminate general proteasome inhibitors, and finally an iterative process to optimize structure-activity relationships. This resulted in the identification of BioFocus 844 (BF844). To test the efficacy of BF844, we developed a mouse model that mimicked the progressive hearing loss associated with USH3. BF844 effectively attenuated progressive hearing loss and prevented deafness in this model. Because the CLRN1(N48K) mutation causes both hearing and vision loss, BF844 could in principle prevent both sensory deficiencies in patients with USH3. Moreover, the strategy described here could help identify drugs for other protein-destabilizing monogenic disorders.
2012-01-01
Background Hearing impairment at the workplace, and the resulting psychosocial problems are a major health problem with substantial costs for employees, companies, and society. Therefore, it is important to develop interventions to support hearing impaired employees. The objective of this article is to describe the design of a randomized controlled trial evaluating the (cost-) effectiveness of a Vocational Enablement Protocol (VEP) compared with usual care. Methods/Design Participants will be selected with the 'Hearing and Distress Screener'. The study population will consist of 160 hearing impaired employees. The VEP intervention group will be compared with usual care. The VEP integrated care programme consists of a multidisciplinary assessment of auditory function, work demands, and personal characteristics. The goal of the intervention is to facilitate participation in work. The primary outcome measure of the study is 'need for recovery after work'. Secondary outcome measures are coping with hearing impairment, distress, self-efficacy, psychosocial workload, job control, general health status, sick leave, work productivity, and health care use. Outcome measures will be assessed by questionnaires at baseline, and 3, 6, 9, and 12 months after baseline. The economic evaluation will be performed from both a societal and a company perspective. A process evaluation will also be performed. Discussion Interventions addressing occupational difficulties of hearing impaired employees are rare but highly needed. If the VEP integrated care programme proves to be (cost-) effective, the intervention can have an impact on the well-being of hearing impaired employees, and thereby, on the costs for the company as well for the society. Trial registration Netherlands Trial Register (NTR): NTR2782 PMID:22380920
Digital retinal imaging in a residency-based patient-centered medical home.
Newman, Robert; Cummings, Doyle M; Doherty, Lisa; Patel, Nick R
2012-03-01
Diabetic retinopathy is the leading cause of blindness in adults in the United States, and early screening/treatment may preserve vision. This study examined the feasibility of using non-mydriatic digital retinal imaging (DRI) for retinopathy screening in a busy family medicine residency program at the point of care using a nurse-driven protocol. We compared the number of diabetics screened during a 1-year period before and after DRI protocol implementation. We also determined the prevalence of retinopathy, assessed patient satisfaction with the alternative screening process, and tracked ophthalmologic appointment compliance for patients referred because of abnormal screening results. Screening approximately doubled from 161 patients/year before the protocol to 330 patients/year after protocol implementation. However, DRI screening had no impact on ophthalmologic appointment compliance; only 58% of 153 patients referred for ophthalmologic evaluation because of positive screening findings completed their referral appointment. Seven cases needing urgent ophthalmologic treatment were identified. Satisfaction with primary care retinopathy screening was high. Use of a nurse-driven protocol for digital retinal imaging at the point of care dramatically improves rates of annual retinopathy screening in academic family medicine practice and can identify patients who require subspecialty referral. However, DRI screening does not improve visit compliance rates with ophthalmologists for evaluation and management.
Keohane, Bernie M; Mason, Steve M; Baguley, David M
2004-02-01
A novel auditory brainstem response (ABR) detection and scoring algorithm, entitled the Vector algorithm is described. An independent clinical evaluation of the algorithm using 464 tests (120 non-stimulated and 344 stimulated tests) on 60 infants, with a mean age of approximately 6.5 weeks, estimated test sensitivity greater than 0.99 and test specificity at 0.87 for one test. Specificity was estimated to be greater than 0.95 for a two stage screen. Test times were of the order of 1.5 minutes per ear for detection of an ABR and 4.5 minutes per ear in the absence of a clear response. The Vector algorithm is commercially available for both automated screening and threshold estimation in hearing screening devices.
Störbeck, Claudine; Young, Alys
2016-03-22
Identification of deafness before 3 months of age substantially improves the socio-linguistic and cognitive development of deaf children. Existing studies demonstrating the feasibility of newborn hearing screening in South Africa have used small samples unrepresentative of general population characteristics. This study establishes the characteristics of the largest data set of deaf infants and their families in South Africa on which there is baseline and longitudinal data (n = 532); explores its representativeness in terms of socio-demographic features and reports on access to and quality of newborn hearing screening within the sample. It examines specifically the relationship between age of maternal suspicion of childhood deafness and age of identification of deafness by cohort characteristics. Secondary analysis, using descriptive and inferential statistics, of a pre-existing longitudinal data set (n = 532) of deaf infants under 6 years of age, and their families, collected as routine monitoring of the HI HOPES (HH) early intervention programme. The HH cohort is representative in terms of racial profile and private/public health care use but displays slightly higher level of maternal education and slightly lower socio-economic status than national comparators. 102 out of 532 infants had undergone newborn hearing screening, resulting in 29 true positives, 15 of whom would have met the criteria for targeted screening. Later onset deafness does not account for the 73 false negatives. The median age of maternal suspicion (n = 247) of infant deafness was 18 months; the median age of identification of 28 months. Age of identification was unrelated to private/public health care status. The median delay between age of suspicion and age of identification was significantly longer in the public sector (7 m; IQR 0-15 m) compared to the private sector (2 m; IQR 0-8.5 m) (p = 0.035). Age of suspicion was unrelated to level of maternal education. Earlier age of suspicion did not predict earlier identification. Targeted screening as timely response to maternal suspicion offers a viable means to reduce substantially the age of identification of deafness in South Africa until implementation of newborn hearing screening on a population-wide basis can be justified.
Vas, Venessa; Akeroyd, Michael A; Hall, Deborah A
2016-01-01
Introduction Hearing loss is a highly prevalent condition that affects around 1 in 6 people in the UK alone. This number is predicted to rise by the year 2031 to a staggering 14.5 million people due to the ageing population of the UK. Currently, the most common intervention for hearing loss is amplification with hearing aid(s) which serve to address the issue of audibility due to hearing loss, but cannot reverse its effects. The consequences of hearing loss are multifaceted, as it is a complex condition that can detrimentally affect various aspects of an individual's life, including communication and personal relationships. The scope of these reported issues is so broad that it calls on the need for patient-centred management plans that are tailored to each patient as well as appropriate measures to assess intervention benefit. It is unclear whether current outcome instruments adequately match what patients report as the most important problems for them. Methods and analysis The systematic review aims to capture existing knowledge about patients and their communication partner's perspective on the everyday impact of hearing loss. Methods are defined according to the Preferred Reporting Items for Systematic reviews and Meta-analyses for Protocols (PRISMA-P) 2015. Ethics and dissemination No ethical issues are foreseen. Findings will be reported in student's thesis as well as at national and international ENT/audiology conferences and in a peer-reviewed journal. Systematic review registration number PROSPERO CRD42015024914. PMID:27645555
Zebrack, Brad; Kayser, Karen; Bybee, Deborah; Padgett, Lynne; Sundstrom, Laura; Jobin, Chad; Oktay, Julianne
2017-07-01
Background: This study examined the extent to which cancer programs demonstrated adherence to their own prescribed screening protocol, and whether adherence to that protocol was associated with medical service utilization. The hypothesis is that higher rates of service utilization are associated with lower rates of adherence to screening protocols. Methods: Oncology social workers at Commission on Cancer-accredited cancer programs reviewed electronic health records (EHRs) in their respective cancer programs during a 2-month period in 2014. Rates of overall adherence to a prescribed distress screening protocol were calculated based on documentation in the EHR that screening adherence and an appropriate clinical response had occurred. We examined documentation of emergency department (ED) use and hospitalization within 2 months after the screening visit. Results: Review of 8,409 EHRs across 55 cancer centers indicated that the overall adherence rate to screening protocols was 62.7%. The highest rates of adherence were observed in Community Cancer Programs (76.3%) and the lowest rates were in NCI-designated Cancer Centers (43.3%). Rates of medical service utilization were significantly higher than expected when overall protocol adherence was lacking. After controlling for patient and institutional characteristics, risk ratios for ED use (0.82) and hospitalization (0.81) suggest that when overall protocol adherence was documented, 18% to 19% fewer patients used these medical services. Conclusions: The observed associations between a mandated psychosocial care protocol and medical service utilization suggest opportunities for operational efficiencies and costs savings. Further investigations of protocol integrity, as well as the clinical care models by which psychosocial care is delivered, are warranted. Copyright © 2017 by the National Comprehensive Cancer Network.
The use of a photoionization detector to detect harmful volatile chemicals by emergency personnel
Patel, Neil D; Fales, William D; Farrell, Robert N
2009-01-01
Objective The objective of this investigation was to determine if a photoionization detector (PID) could be used to detect the presence of a simulated harmful chemical on simulated casualties of a chemical release. Methods A screening protocol, based on existing radiation screening protocols, was developed for the purposes of the investigation. Three simulated casualties were contaminated with a simulated chemical agent and two groups of emergency responders were involved in the trials. The success–failure ratio of the participants was used to judge the performance of the PID in this application. Results A high success rate was observed when the screening protocol was properly adhered to (97.67%). Conversely, the success rate suffered when participants deviated from the protocol (86.31%). With one exception, all failures were noted to have been the result of a failure to correctly observe the established screening protocol. Conclusions The results of this investigation indicate that the PID may be an effective screening tool for emergency responders. However, additional study is necessary to both confirm the effectiveness of the PID and refine the screening protocol if necessary. PMID:27147829
Follow-Up Activities for the HISD Kindergarten Screening Instrument.
ERIC Educational Resources Information Center
Perry, Pat; Cater, Margot
The Kindergarten Screening Instrument consists of five sub-scales and attempts to screen for possible difficulty in the areas of distant vision, hearing, eye-hand coordination, language learning, and gross motor performance. In response to many requests for follow-up activities after screening, this manual was prepared by Volunteers in Public…
A Comparison of Health Screenings in Rural and Urban Schools in Missouri.
ERIC Educational Resources Information Center
Waignandt, Alex; Brown, James
1991-01-01
Studied health screening methods of schools in mid-Missouri. Found significant differences between rural and urban schools in terms of number of school nurses employed and percentage of schools screening in all areas studied: physical assessment, vision, hearing, scoliosis, and dental. Recommends improved health screenings in rural schools. (KS)
Liu, Xin-Ying; Han, Ying; Yang, Shi-Ming
2016-12-01
HHIE-S can be a useful tool in investigating hearing loss among people over 80 years old, with the same validity as HHIE. To investigate the effect of hearing loss on the quality-of-life in people over 80 years of age in China, and to compare the results of the Chinese mandarin version Hearing Handicap Inventory for the Elderly (HHIE) and its screening version (HHIE-S). Eighty-four people over 80 years participated in the study. Both HHIE and HHIE-S were completed, and the hearing handicap degrees were rated according to HHIE scores and HHIE-S scores, respectively. Results obtained by HHIE and HHIE-S were compared. Multi-factor analysis of variance was used to analyze the impact of eight factors on hearing handicap in the oldest old people over 80 years of age, including age, noise exposure, ear surgery, infection, ototoxic drugs use, cardiovascular and cerebrovascular diseases, diabetes, and tumors. Both HHIE and HHIE-S revealed 48 subjects (57.1%) with no self-perceived hearing problem, and 36 subjects (42.9%) with hearing handicap. No statistical difference was found between results of the functional hearing handicap rating by HHIE and HHIE-S (Chi-square = 1.532, p = 0.465). The HHIE and HHIE-S were in agreement with each other (kappa = 0.772, p < 0.001). All the eight factors had no significance on both HHIE and HHIE-S scores (p > 0.05), except noise exposure on S-score of HHIE-S (p = 0.032), and the R-squares of these factors were less than 5%.
Núñez-Batalla, Faustino; Noriega-Iglesias, Sabel; Guntín-García, Maite; Carro-Fernández, Pilar; Llorente-Pendás, José Luis
2016-01-01
Conventional audiometry is the gold standard for quantifying and describing hearing loss. Alternative methods become necessary to assess subjects who are too young to respond reliably. Auditory evoked potentials constitute the most widely used method for determining hearing thresholds objectively; however, this stimulus is not frequency specific. The advent of the auditory steady-state response (ASSR) leads to more specific threshold determination. The current study describes and compares ASSR, auditory brainstem response (ABR) and conventional behavioural tone audiometry thresholds in a group of infants with various degrees of hearing loss. A comparison was made between ASSR, ABR and behavioural hearing thresholds in 35 infants detected in the neonatal hearing screening program. Mean difference scores (±SD) between ABR and high frequency ABR thresholds were 11.2 dB (±13) and 10.2 dB (±11). Pearson correlations between the ASSR and audiometry thresholds were 0.80 and 0.91 (500Hz); 0.84 and 0.82 (1000Hz); 0.85 and 0.84 (2000Hz); and 0.83 and 0.82 (4000Hz). The ASSR technique is a valuable extension of the clinical test battery for hearing-impaired children. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Weiss, Jakob; Martirosian, Petros; Notohamiprodjo, Mike; Kaufmann, Sascha; Othman, Ahmed E; Grosse, Ulrich; Nikolaou, Konstantin; Gatidis, Sergios
2018-03-01
The aims of this study were to establish a 5-minute magnetic resonance (MR) screening protocol for prostate cancer in men before biopsy and to evaluate effects on Prostate Imaging Reporting and Data System (PI-RADS) V2 scoring in comparison to a conventional, fully diagnostic multiparametric MR imaging (mpMRI) approach. Fifty-two patients with elevated prostate-specific antigen levels and without prior biopsy were prospectively included in this institutional review board-approved study. In all patients, an mpMRI protocol according to the PI-RADS recommendations was acquired on a 3 T MRI system. In addition, an accelerated diffusion-weighted imaging sequence was acquired using simultaneous multislice technique (DW-EPISMS). Two readers independently evaluated the images for the presence/absence of prostate cancer according to the PI-RADS criteria and for additional findings. In a first reading session, only the screening protocol consisting of axial T2-weighted and DW-EPISMS images was made available. In a subsequent reading session, the mpMRI protocol was assessed blinded to the results of the first reading, serving as reference standard. Both readers successfully established a final diagnosis according to the PI-RADS criteria in the screening and mpMRI protocol. Mean lesion size was 1.2 cm in the screening and 1.4 cm in the mpMRI protocol (P = 0.4) with 35% (18/52) of PI-RADS IV/V lesions. Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100% for both readers with no significant differences in comparison to the mpMRI standard (P = 1.0). In 3 patients, suspicious lymph nodes were reported as additional finding, which were equally detectable in the screening and mpMRI protocol. A 5-minute MR screening protocol for prostate cancer in men with elevated prostate-specific antigen levels before biopsy is applicable for clinical routine with similar diagnostic performance as the full diagnostic mpMRI approach.
Cordblood-Based High-Throughput Screening for Deafness Gene of 646 Newborns in Jinan Area of China
Li, Shou-Xia; Chen, Ding-Li; Zhao, Su-Bin; Guo, Li-Li; Feng, Hai-Qin; Zhang, Xiao-Fang; Ping, Li-Li; Yang, Zhi-Ming; Sun, Cai-Xia
2015-01-01
Objectives Infants with slight/mild or late-onset hearing impairment might be missed in universal newborn hearing screening (UNHS). We identified the mutation hot spot of common deaf gene in the newborns in Jinan area population by screening the mutation spot with neonate cord blood, in order to make clear whether the neonate cord blood for screening is feasible. Methods Six hundred and forty-six newborns were subjected to both UNHS and genetic screening for deafness by using neonate cord blood. The newborn genetic screening targeted four deafness-associated genes, which were commonly found in the Chinese population including gap junction beta-2 protein (GJB2), gap junction beta-3 protein (GJB3), solute carrier family 26 member 4 (SLC26A4), and mtDNA 12S rRNA. The most common 20 spot mutations in 4 deaf genes were detected by MassARRAY iPLEX platform and mitochondrial 12S rRNA A1555G and C1494T mutations were sequenced using Sanger sequencing. Results Among the 646 newborns, 635 cases passed the UNHS and the other 11 cases (1.7%) did not. Of the 11 failures, two cases were found to carry homozygous GJB2 p.R143W pathogenic mutation, one case was found to have heterozygous GJB2 235delC mutation, and another one case carried heterozygous GJB3 p.R180X pathogenic mutation. Six hundred and thirty-five babies passed the newborn hearing screening, in which 25 babies were identified to carry pathogenic mutations, including 12 heterozygotes (1.9%) for GJB2 235delC, eight heterozygotes (1.3%) for SLC26A4 IVS7-2A>G, one heterozygote (0.2%) for p.R409H, two homozygotes (0.3%) for m.1494C>T, and two homozygotes (0.3%) for m.1555A>G. Conclusion Newborn genetic screening through the umbilical cord blood for common deafness-associated mutations may identify carriers sensitive to aminoglycoside antibiotic, and can effectively prevent or delay hearing loss occurs. PMID:26330914
Hearing Loss in HIV-Infected Children in Lilongwe, Malawi
Hrapcak, Susan; Kuper, Hannah; Bartlett, Peter; Devendra, Akash; Makawa, Atupele; Kim, Maria; Kazembe, Peter; Ahmed, Saeed
2016-01-01
Introduction With improved access to antiretroviral therapy (ART), HIV infection is becoming a chronic illness. Preliminary data suggest that HIV-infected children have a higher risk of disabilities, including hearing impairment, although data are sparse. This study aimed to estimate the prevalence and types of hearing loss in HIV-infected children in Lilongwe, Malawi. Methods This was a cross-sectional survey of 380 HIV-infected children aged 4–14 years attending ART clinic in Lilongwe between December 2013-March 2014. Data was collected through pediatric quality of life and sociodemographic questionnaires, electronic medical record review, and detailed audiologic testing. Hearing loss was defined as >20 decibels hearing level (dBHL) in either ear. Predictors of hearing loss were explored by regression analysis generating age- and sex-adjusted odds ratios. Children with significant hearing loss were fitted with hearing aids. Results Of 380 patients, 24% had hearing loss: 82% conductive, 14% sensorineural, and 4% mixed. Twenty-one patients (23% of those with hearing loss) were referred for hearing aid fitting. There was a higher prevalence of hearing loss in children with history of frequent ear infections (OR 7.4, 4.2–13.0) and ear drainage (OR 6.4, 3.6–11.6). Hearing loss was linked to history of WHO Stage 3 (OR 2.4, 1.2–4.5) or Stage 4 (OR 6.4, 2.7–15.2) and history of malnutrition (OR 2.1, 1.3–3.5), but not to duration of ART or CD4. Only 40% of caregivers accurately perceived their child’s hearing loss. Children with hearing impairment were less likely to attend school and had poorer emotional (p = 0.02) and school functioning (p = 0.04). Conclusions There is an urgent need for improved screening tools, identification and treatment of hearing problems in HIV-infected children, as hearing loss was common in this group and affected school functioning and quality of life. Clear strategies were identified for prevention and treatment, since most hearing loss was conductive in nature, likely due to frequent ear infections, and many children with hearing loss qualified for hearing aids. Screening strategies need to be developed and tested since caregivers were not reliable at identifying hearing loss, and often mis-identified children with normal hearing as having hearing loss. Children with frequent ear infections, ear drainage, TB, severe HIV disease, or low BMI should receive more frequent ear assessments and hearing evaluations. PMID:27551970
Bush, Matthew L; Taylor, Zachary R; Noblitt, Bryce; Shackleford, Taylor; Gal, Thomas J; Shinn, Jennifer B; Creel, Liza M; Lester, Cathy; Westgate, Philip M; Jacobs, Julie A; Studts, Christina R
2017-11-01
To assess the efficacy of a patient navigator intervention to decrease nonadherence to obtain audiological testing following failed screening, compared to those receiving the standard of care. Using a randomized controlled design, guardian-infant dyads, in which the infants had abnormal newborn hearing screening, were recruited within the first week after birth. All participants were referred for definitive audiological diagnostic testing. Dyads were randomized into a patient navigator study arm or standard of care arm. The primary outcome was the percentage of patients with follow-up nonadherence to obtain diagnostic testing. Secondary outcomes were parental knowledge of infant hearing testing recommendations and barriers in obtaining follow-up testing. Sixty-one dyads were enrolled in the study (patient navigator arm = 27, standard of care arm = 34). The percentage of participants nonadherent to diagnostic follow-up during the first 6 months after birth was significantly lower in the patient navigator arm compared with the standard of care arm (7.4% vs. 38.2%) (P = .005). The timing of initial follow-up was significantly lower in the navigator arm compared with the standard of care arm (67.9 days after birth vs. 105.9 days, P = .010). Patient navigation increased baseline knowledge regarding infant hearing loss diagnosis recommendations compared with the standard of care (P = .004). Patient navigation decreases nonadherence rates following abnormal infant hearing screening and improves knowledge of follow-up recommendations. This intervention has the potential to improve the timeliness of delivery of infant hearing healthcare; future research is needed to assess the cost and feasibility of larger scale implementation. 1b. Laryngoscope, 127:S1-S13, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Lino, Valéria Teresa Saraiva; Portela, Margareth Crisóstomo; Camacho, Luiz Antonio Bastos; Rodrigues, Nadia Cristina Pinheiro; Andrade, Monica Kramer de Noronha; O'Dwyer, Gisele
2016-07-21
The objectives were to examine psychometric properties of a screening test for the elderly and to propose a protocol for use in primary care. The method consisted of four stages: (1) inter-evaluator reliability for performance tests and self-assessment questions for eight functions; (2) sensitivity and specificity of questions on depression and social support; (3) meeting of experts to select instrumental activities of daily living (IADL); and (4) elaboration of the protocol. Screening lasted 16 minutes. Inter-evaluator reliability was excellent for performance tests but poor for questions. Depression and social support showed satisfactory sensitivity and specificity (0.74/0.77 and 0.77/0.96). Four IADL were selected by more than 55% of the experts. Following the results, a screening protocol was elaborated that prioritized the use of performance tests, maintaining questions on mood, social support, and IADL. The study suggests better reproducibility of performance tests when compared to questions. For mood and social support, the questions may provide a first screening stage. The proposed protocol allows rapid screening of problems.
Implementation of lung cancer CT screening in the Nordic countries.
Pedersen, Jesper Holst; Sørensen, Jens Benn; Saghir, Zaigham; Fløtten, Øystein; Brustugun, Odd Terje; Ashraf, Haseem; Strand, Trond-Eirik; Friesland, Signe; Koyi, Hirsh; Ek, Lars; Nyrén, Sven; Bergman, Per; Jekunen, Antti; Nieminen, Eeva-Maija; Gudbjartsson, Tomas
2017-10-01
We review the current knowledge of CT screening for lung cancer and present an expert-based, joint protocol for the proper implementation of screening in the Nordic countries. Experts representing all the Nordic countries performed literature review and concensus for a joint protocol for lung cancer screening. Areas of concern and caution are presented and discussed. We suggest to perform CT screening pilot studies in the Nordic countries in order to gain experience and develop specific and safe protocols for the implementation of such a program.
Calibration of an In-Ear Dosimeter for a Single Hearing Protection Device
2014-02-01
history of ototoxic medication use, audiological history of tinnitus , etc. A total of 54 subjects were screened to participate in this study.1 subject...was excluded from this study based on a history of seizures. 18 subjects were excluded based on hearing threshold results. 15 subjects were...Military Service: Implications for hearing loss and tinnitus ”, Washington, DC, National Academies Press. 7. United States Government Accountability Office
Wang, Yue; Mo, Lingyan; Li, Yagang; Zheng, Zhongwei; Qi, Yu
2017-04-01
The aim of the present study was to investigate the use of Chinese version of HHIE-S as a hearing screening tool for the elderly in an industrial area in northeast China. Prevalence, sensitivity and specificity of Chinese version of HHIE-S were calculated. Factors that had impact on HHIE-S were analysed. Five hundred and seventy Mandarin speaking participants, aged from 50 to 85 years were included. They were tested with pure tone audiometry and Chinese version of HHIE-S. The prevalence of hearing handicap was 55.3%. The sensitivity and specificity of HHIE-S were 84.5% and 58.3% respectively when the pass/fail criteria were set at PTA 0.5-4kHz >40 dBHL. In general, HHIE-S total and subscale scores were significantly associated with severity of hearing impairment. After stratified by severity of hearing impairment, both the prevalence of reported handicap and the scores of HHIE-S were not significantly associated with age. Male participants had significantly higher HHIE-S scores than female participants did. The Chinese version of HHIE-S contributes useful information to identifying hearing handicap and addressing the rehabilitative needs in the elderly in an industrial city in Mainland China.
Newborn Hearing Screening and Early Diagnostic in the NICU
Colella-Santos, Maria Francisca; Hein, Thaís Antonelli Diniz; de Souza, Gabriele Libano; do Amaral, Maria Isabel Ramos; Casali, Raquel Leme
2014-01-01
The aim was to describe the outcome of neonatal hearing screening (NHS) and audiological diagnosis in neonates in the NICU. The sample was divided into Group I: neonates who underwent NHS in one step and Group II: neonates who underwent a test and retest NHS. NHS procedure was automated auditory brainstem response. NHS was performed in 82.1% of surviving neonates. For GI, referral rate was 18.6% and false-positive was 62.2% (normal hearing in the diagnostic stage). In GII, with retest, referral rate dropped to 4.1% and false-positive to 12.5%. Sensorineural hearing loss was found in 13.2% of infants and conductive in 26.4% of cases. There was one case of auditory neuropathy spectrum (1.9%). Dropout rate in whole process was 21.7% for GI and 24.03% for GII. We concluded that it was not possible to perform universal NHS in the studied sample or, in many cases, to apply it within the first month of life. Retest reduced failure and false-positive rate and did not increase evasion, indicating that it is a recommendable step in NHS programs in the NICU. The incidence of hearing loss was 2.9%, considering sensorineural hearing loss (0.91%), conductive (1.83%) and auditory neuropathy spectrum (0.19%). PMID:24999481
Readability of Internet Information on Hearing: Systematic Literature Review.
Laplante-Lévesque, Ariane; Thorén, Elisabet Sundewall
2015-09-01
This systematic literature review asks the following question: “ What is the readability of Internet information on hearing that people with hearing impairment and their significant others can access in the context of their hearing care?” Searches were completed in three databases: CINAHL, PubMed, and Scopus. Seventy-eight records were identified and systematically screened for eligibility: 8 records were included that contained data on the readability of Internet information on hearing that people with hear ing impairment and their significant others can access in the context of their hearing care. Records reported mean readability levels from 9 to over 14. In other words, people with hearing impairment and their significant others need 9 to 14 years of education to read and understand Internet information on hearing that they access in the context of their hearing care. The poor readability of Internet information on hearing has been well documented; it is time to focus on valid and sustainable initiatives that address this problem.
Health Vulnerability Index and newborn hearing screening: urban inequality.
Januário, Gabriela Cintra; Alves, Claudia Regina Lindgren; Lemos, Stela Maris Aguiar; Almeida, Maria Cristina de Mattos; Cruz, Ramon Costa; Friche, Amélia Augusta de Lima
To analyze the intra-urban differentials related to the outcome of the Newborn Hearing Screening (NHS) of children living in Belo Horizonte tested in a reference service using the Health Vulnerability Index (HVI). cross-sectional study with children living in Belo Horizonte evaluated by a Newborn Hearing Screening Reference Service (NHSRS) between 2010 and 2011. The HVI of the census tract of each child was obtained by the georeferencing of their respective addresses. Multivariate analysis was conducted using the decision tree technique, considering a statistical model for each response. A thematic map of points representing the geographic distribution of the children evaluated by the NHS program was also developed. The NHS failure rate for children living in areas with very high HVI, or without HVI data, was 1.5 times higher than that for children living in other census tracts. For children living in areas of low, medium, and high HVI, who underwent NHS after 30 days of life, the NHS failure rate was 2.1 times higher in children that presented Risk Indicator for Hearing Loss (RIHL) (17.2%) than in those who did not (8.1%). Uneven distribution was observed between areas for children that underwent the NHS and those who failed it. Significant intra-urban differentials were found in Belo Horizonte, indicating correlation between health vulnerability and NHS outcomes.
[Ear, nose and throat disease profile in children with Down syndrome].
Paul D, María A; Bravo V, Alejandra; Beltrán M, Constanza; Cerda L, Jaime; Angulo M, Daniela; Lizama C, Macarena
2015-01-01
The children with Down syndrome (DS) are at increased risk of ear-nose-throat (ENT) disorders. International recommendations suggest early hearing screening and periodic specialist evaluation. Our goal was to characterize ENT disorders in children with DS, and propose recommendations for the Chilean population. Cross-sectional, descriptive study, of children with DS, between 6 months and 15 years of age. The data was obtained by a health interview to the parents and review of medical records. We analyzed 134 patients with an average age of 44.5 months. The 78.8% had ENT disorders, the most frequent ENT disorders was allergic rhinitis and otitis media with effusion. Hearing screening was abnormal in a quarter of the patients, 50% of children over 3 years of age had obstructive sleep apnea diagnosed by polysomnogram. Older children had a statistically higher frequency of ENT disorders. This series shows a high rate of ENT disorders in children with DS, which supports recommendations for hearing screening, high suspicion of obstructive sleep apnea and routine referral to an ENT specialist for prevention and aggressive therapy in order to reduce hearing loss and improve development of the child with DS. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.
Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J
2012-08-01
Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.
Screening for Usher Syndrome: A Hands-On Guide for School Nurses.
ERIC Educational Resources Information Center
Houghton, Joan; Coonts, Teresa; Jordan, Beth; Schafer, Jacqueline, Ed.
This manual was written specifically to help school nurses conduct screenings for Usher syndrome, a genetic condition that involves deafness or hearing loss and the progressive loss of vision. It provides information on the step-by-step process of how to conduct a screening, the actual forms needed for a screening, and resources for referring…
Moulin, A; Ferber-Viart, C; Berland, M; Dubreuil, C; Duclaux, R
2001-09-01
Evaluation of the feasibility and parental attitudes towards a hearing screening programme using evoked otoacoustic emissions, implemented in a maternity ward in France. A hearing screening test using transiently evoked otoacoustic emissions (TEOAE) was proposed to each baby, and an anonymous questionnaire was given to parents to assess their attitudes towards the screening procedure. Although the refusal of the test reached 16% (mainly during the first two weeks of the program), more than 92% of parents judged the test as being useful, and 65% wished it to be systematically done. However, nearly 35% of parents admitted to have a low level anxiety about being unnecessarily worried by the test results. One hundred and twenty-four babies were screened. Fifty three per cent of the tests have been performed in less than ten minutes, with an average of 12.2 minutes. This duration does not include delays due to programme and babies management. False positive rate (uni or bilateral fail) was 10.5% at the first stage. Repeating the test before discharge decreased the false positive rate to 6.5%. Although limited in time, this study shows that a systematic hearing screening programme using TEOAE is possible and should be done in France. False positive rate was below 7%, and the test was considered as useful by more than 90% of parents, although knowledge about deafness in childhood and its consequences were clearly insufficient.
Abbreviated MRI Protocols: Wave of the Future for Breast Cancer Screening.
Chhor, Chloe M; Mercado, Cecilia L
2017-02-01
The purpose of this article is to describe the use of abbreviated breast MRI protocols for improving access to screening for women at intermediate risk. Breast MRI is not a cost-effective modality for screening women at intermediate risk, including those with dense breast tissue as the only risk. Abbreviated breast MRI protocols have been proposed as a way of achieving efficiency and rapid throughput. Use of these abbreviated protocols may increase availability and provide women with greater access to breast MRI.
A Retrospective Estimate of Ear Disease Detection Using the "Red Flags" in a Clinical Sample.
Klyn, Niall A M; Kleindienst Robler, Samantha; Alfakir, Razan; Nielsen, Donald W; Griffith, James W; Carlson, Deborah L; Lundy, Larry; Dhar, Sumitrajit; Zapala, David A
2018-03-01
The purpose of this study was to evaluate the specificity and sensitivity of two red flag protocols in detecting ear diseases associated with changes in hearing. The presence of red-flag symptoms was determined in a chart review of 307 adult patients from the Mayo Clinic Florida Departments of Otorhinolaryngology and Audiology. Participants formed a convenience sample recruited for a separate study. Neurotologist diagnosis was the criterion for comparisons. Of the 251 patient files retained for analysis, 191 had one or more targeted diseases and 60 had age- or noise-related hearing loss. Food and Drug Administration red flags sensitivity was 91% (confidence interval [CI], 86 to 95%) and specificity was 72% (CI, 59 to 83%). American Academy of Otolaryngology-Head and Neck Surgery red flags sensitivity was 98% (CI, 95 to 99%) and specificity was 20% (CI, 11 to 32%). Stakeholders must determine which diseases are meaningful contraindications for hearing aid use and whether these red-flag protocols have acceptable levels of sensitivity and specificity. As direct-to-consumer models of hearing devices increase, a disease detection method that does not require provider intercession would be useful.
Chang, Hsin-Pin; Ho, Chin-Yu; Chou, Pesus
2009-10-01
Elderly persons with a physiologic hearing deficit (hearing impairment) are not necessarily socially or emotionally disturbed by the deficit in everyday life (hearing handicap). The self-perception of a hearing handicap in elderly people is a key element in seeking consultation for a hearing impairment or using hearing aids. Thus, it is important to determine the factors associated with the self-perception of a hearing handicap. The aims of the present study were to report the relation between a hearing impairment and the self-perception of a hearing handicap, and the factors associated with a self-perceived hearing handicap among a group of randomly recruited, community-dwelling elderly persons, aged 65 yr and older, in Taipei, Taiwan. A cross-sectional survey of community-dwelling elderly persons aged 65 yr and older (N = 1220) participating in an annual general purpose geriatric health examination in 2005 in Taipei. Pure-tone audiometry and a questionnaire including the Hearing Handicap Inventory for the Elderly-Screening Version (HHIE-S) were administered, after obtaining the subject's consent to participate in the study. Demographic information, lifestyle, self-report health status, and biochemical data were also collected. There was a moderate association (gamma(s) = 0.52) between hearing impairment and self-perceived handicap. Only 21.4% of the study subjects with moderate to profound hearing impairment (M4 >or=41 dB HL, N = 555) perceived themselves as hearing-handicapped (HHIE-S total score >or=10). Besides hearing level, marital status (widowed) and self-perceived general health (bad or neutral) were factors that are significantly associated with a self-perceived hearing handicap among elderly subjects with moderate to profound hearing impairment. For study subjects with moderate to profound hearing impairment (M4 >or=41 dB HL), 5.0% of those with HHIE-S <10 and 45.4% of those with HHIE-S >or=10 used or felt that they required hearing aids (chi2 test, p < 0.001). These data suggested that a self-perceived hearing handicap (HHIE-S >or=10) is an important indicator for referral of elderly persons for hearing-aid fitting. Our study findings, consistent with those of previous studies, demonstrated that not all elderly persons with impaired hearing function (hearing impairment) perceived a hearing deficit socially or emotionally in everyday life (hearing handicap). Marital status (widowed) and bad/neutral general health were nonaudiologically associated factors with a hearing handicap in the present study. Further, those with a self-perceived hearing handicap reported a higher rate of the use of, or requirement for, hearing aids. Because hearing deterioration is a common biologic process of aging, the results of this study can be used to identify the groups among elderly people with a greater need for hearing screening and hearing rehabilitation services.
Screening of Visually Impaired Children for Health Problems.
Açıl, Dilay; Ayaz, Sultan
2015-12-01
Disability is a significant problem and is accepted globally as a health priority in childhood. Like nonvisually impaired children, visually impaired children also need to use health services during childhood. The purpose of this study was to determine the health problems of visually impaired children. A descriptive design was used. The subjects were 74 children with visual impairment attending primary school (aged 5-14 years), who agreed to participate and whose parents gave permission. Data were collected via physical examination including questionnaires and a physical assessment form. The health screening included physical measurements for height, weight, blood pressure, dental health, hearing, and scoliosis. The mean age of children was 10.43 ± 2.9 years. When the health screening results of children were examined, it was found that 25.7% of the children were overweight or obese, 35.1% of them had dental problems, 27.0% had hearing problems, and 39.2% had scoliosis risk. Systolic and diastolic blood pressures were normal in 91.8% and 93.2% of the children, respectively. These findings showed the important role of school health nurses in performing health screenings directed at visually impaired children who constitute a special group for school health services. Health screening for height, weight, dental health, hearing, and scoliosis is suggested for visually impaired children. Copyright © 2015. Published by Elsevier B.V.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-26
... of display screens, wireless headsets, and simultaneous transmission capabilities in handsets. The... Communications Commission. ACTION: Proposed rule. SUMMARY: In this document, the Wireless Telecommunications... relating to hearing aid compatibility of wireless handsets. The Bureau seeks updated comment on whether, in...
76 FR 2625 - Comment Sought on 2010 Review of Hearing Aid Compatibility Regulations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-14
... compatibility, as well as the effects of display screens, wireless headsets, and simultaneous transmission.... ACTION: Proposed rule. SUMMARY: The Wireless Telecommunications Bureau (Bureau) seeks comments on the operation and effectiveness of the Commission's rules relating to hearing aid compatibility of wireless...
Vas, Venessa; Akeroyd, Michael A; Hall, Deborah A
2016-09-19
Hearing loss is a highly prevalent condition that affects around 1 in 6 people in the UK alone. This number is predicted to rise by the year 2031 to a staggering 14.5 million people due to the ageing population of the UK. Currently, the most common intervention for hearing loss is amplification with hearing aid(s) which serve to address the issue of audibility due to hearing loss, but cannot reverse its effects. The consequences of hearing loss are multifaceted, as it is a complex condition that can detrimentally affect various aspects of an individual's life, including communication and personal relationships. The scope of these reported issues is so broad that it calls on the need for patient-centred management plans that are tailored to each patient as well as appropriate measures to assess intervention benefit. It is unclear whether current outcome instruments adequately match what patients report as the most important problems for them. The systematic review aims to capture existing knowledge about patients and their communication partner's perspective on the everyday impact of hearing loss. Methods are defined according to the Preferred Reporting Items for Systematic reviews and Meta-analyses for Protocols (PRISMA-P) 2015. No ethical issues are foreseen. Findings will be reported in student's thesis as well as at national and international ENT/audiology conferences and in a peer-reviewed journal. PROSPERO CRD42015024914. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Audiology in Latin America: hearing impairment, resources and services.
Madriz, J J
2001-01-01
Evidence is presented about the limitation of information available on prevalence/incidence of deafness and hearing impairment in the developing world; particularly in Latin America. Two questionnaires on audiological resources and services were mailed to Latin American and Caribbean countries in general and to Central American nations in particular. The information returned by Argentina, Chile, Colombia, Costa Rica, Cuba, Belize, El Salvador, Grenada, Guatemala, Honduras, Mexico, Nicaragua, Panama, Puerto Rico and Uruguay was analysed. Data was gathered about epidemiological studies on hearing impairment, about specific programmes, such as early identification of hearing impairment, national registers on deafness and programmes on hearing screening. Training programmes and availability of professionals in the field of hearing and deafness is also shown. Hearing services, hearing aids provision, hearing testing equipment, professional organization and legislation in audiology is also documented. It is our conclusion that hearing impairment is a low priority for health systems in the developing world, technology continues to be excessively costly and material and human resources are limited, and services are poor and restricted.
Survey on Infant Hearing Loss at Caritas Baby Hospital in Bethlehem-Palestine.
Corradin, Lucia; Hindiyeh, Musa; Khaled, Rasha; Rishmawi, Fadi; Zidan, Marwan; Marzouqa, Hiyam
2014-03-06
This study describes the epidemiology of infants' hearing loss (IHL) among patients under 3 months of age at Caritas Baby Hospital, the only pediatric hospital in Palestine. It was aimed to demonstrate that IHL is a major health problem in Palestine and to assess the first available data of the newborn hearing screening program conducted between September 25, 2006 and December 31, 2011. Data was uploaded and analyzed using Microsoft Excel and the Statistical Package for the Social Sciences software (SPSS version 21). A total of 8144 infants were tested, 4812 (59%) were males and 3332 (41%) were females. As to their origin, 72% (5886) came from the Bethlehem district, 25% (2044) from the Hebron district, while 3% (214) from the other Palestinian districts (Jericho, Ramallah, Nablus, Jenin and Jerusalem). The transient evoked otoacoustic emissions (TEOAEs) and the automated auditory brainstem response were used according to the manufacturer guidelines. The results were interpreted according to the indications of the American Academy of Pediatrics, the National Institutes of Health, and the European Consensus Development Conference on Neonatal Hearing Screening. Out of the 8144 infants tested, 1507 (14.6%) did not pass the 1(st) test, 477 (32.8%) of these 1507 infants failed retesting, while 498 (33%) patients were lost to follow-up. Only 152 (31.9%) patients that failed retesting went to an audiologist. The audiologist evaluation revealed that 101 (66.4%) patients presented with a mild-moderate or profound hearing loss according to the Bureau International of Audiophonologie standards, 44 (28.9%) patients had otitis media, whereas 7 cases (4.7%) had no hearing disorders. The overall unadjusted percentage of hearing loss was 1.24%, and the adjusted overall percentage was 1.85%. The chart review showed that jaundice, sepsis, prematurity, lung disease were more common among the affected patients. The high prevalence of childhood deafness in Palestine is of utmost importance and deserves immediate attention on the part of the Palestinian government. Meanwhile, Caritas Baby Hospital undertook to set up a newborn hearing screening unit utilizing the TEOAE method.
[Working with hearing impairment: an integrated approach].
van Til, Marten J; Kramer, Sophia E; Anema, Johannes R; Goverts, S T Theo
2016-01-01
Patients with hearing impairment are more likely to encounter health problems and difficulties at work than their colleagues with normal hearing. This is often not realised by either patients or professionals. In this article we describe three cases that illustrate how working conditions can influence the health of workers with hearing loss. We have implemented a vocational enablement protocol that follows a multidisciplinary approach in order to meet these patients' needs. Due to a mismatch between the demands of a job and an individual's auditory capacities, even a mild hearing impairment can cause serious problems if a patient works in adverse conditions. In addition, in many workplaces the ability to hear well is a safety issue. Professionals have to be aware of both possibilities. Specialized centres offer good facilities and ensure the optimal transfer of insight into the working environment by involving an occupational physician in their team.
Identifying hearing loss by means of iridology.
Stearn, Natalie; Swanepoel, De Wet
2006-11-13
Isolated reports of hearing loss presenting as markings on the iris exist, but to date the effectiveness of iridology to identify hearing loss has not been investigated. This study therefore aimed to determine the efficacy of iridological analysis in the identification of moderate to profound sensorineural hearing loss in adolescents. A controlled trial was conducted with an iridologist, blind to the actual hearing status of participants, analyzing the irises of participants with and without hearing loss. Fifty hearing impaired and fifty normal hearing subjects, between the ages of 15 and 19 years, controlled for gender, participated in the study. An experienced iridologist analyzed the randomised set of participants' irises. A 70% correct identification of hearing status was obtained by iridological analyses with a false negative rate of 41% compared to a 19% false positive rate. The respective sensitivity and specificity rates therefore came to 59% and 81%. Iridological analysis of hearing status indicated a statistically significant relationship to actual hearing status (P < 0.05). Although statistically significant sensitivity and specificity rates for identifying hearing loss by iridology were not comparable to those of traditional audiological screening procedures.
Road Traffic Noise Exposure and Hearing Impairment Among Traffic Policemen in Surat, Western India
NASA Astrophysics Data System (ADS)
Tandel, B. N.; Macwan, J. E. M.
2017-06-01
Among all of the sources responsible for noise pollution, traffic related sources are of great environmental concern and increasing level of discomfort in urban areas with increasing traffic concentration. It will be a larger and serious problem in the future, if effective precautions are not taken addressed and attended to. Hence, a study was undertaken to measure the levels of road traffic noise at major intersections of Surat city, located in Western India and assess the hearing impairment among the exposed group of population i.e. the traffic policemen. Manual noise measurements and vehicle counts were performed at three of the busiest traffic intersections in the city for a period of 12 h. Audiometric screening was done on 46 policemen working at these intersections to determine the occurrence of hearing impairment. At all the three intersections, Leq measured was well above the permissible levels of 65 dBA for daytime. The Lmax recorded for three intersections were 84.6 dBA (07:36 pm), 87.3 dBA (06:32 pm) and 85.6 dBA (11:41 am). Audiometric screening showed that only 10 policemen (22%) had normal hearing. Slight, moderate and severe hearing impairment was recorded among 13 (28%), 18 (39%) and 5 (11%) policemen respectively. Of the total 46 policemen, none had profound impairment (deafness, hearing loss >81 dB). Of the 36 policemen having hearing impairment, 27 had bilateral impairment.
A new real-time PCR protocol for detection of avian haemosporidians.
Bell, Jeffrey A; Weckstein, Jason D; Fecchio, Alan; Tkach, Vasyl V
2015-07-19
Birds possess the most diverse assemblage of haemosporidian parasites; including three genera, Plasmodium, Haemoproteus, and Leucocytozoon. Currently there are over 200 morphologically identified avian haemosporidian species, although true species richness is unknown due to great genetic diversity and insufficient sampling in highly diverse regions. Studies aimed at surveying haemosporidian diversity involve collecting and screening samples from hundreds to thousands of individuals. Currently, screening relies on microscopy and/or single or nested standard PCR. Although effective, these methods are time and resource consuming, and in the case of microscopy require substantial expertise. Here we report a newly developed real-time PCR protocol designed to quickly and reliably detect all three genera of avian haemosporidians in a single biochemical reaction. Using available DNA sequences from avian haemosporidians we designed primers R330F and R480RL, which flank a 182 base pair fragment of mitochondrial conserved rDNA. These primers were initially tested using real-time PCR on samples from Malawi, Africa, previously screened for avian haemosporidians using traditional nested PCR. Our real time protocol was further tested on 94 samples from the Cerrado biome of Brazil, previously screened using a single PCR assay for haemosporidian parasites. These samples were also amplified using modified nested PCR protocols, allowing for comparisons between the three different screening methods (single PCR, nested PCR, real-time PCR). The real-time PCR protocol successfully identified all three genera of avian haemosporidians from both single and mixed infections previously detected from Malawi. There was no significant difference between the three different screening protocols used for the 94 samples from the Brazilian Cerrado (χ(2) = 0.3429, df = 2, P = 0.842). After proving effective, the real-time protocol was used to screen 2113 Brazilian samples, identifying 693 positive samples. Our real-time PCR assay proved as effective as two widely used molecular screening techniques, single PCR and nested PCR. However, the real-time protocol has the distinct advantage of detecting all three genera in a single reaction, which significantly increases efficiency by greatly decreasing screening time and cost. Our real-time PCR protocol is therefore a valuable tool in the quickly expanding field of avian haemosporidian research.
American Sign Language and Early Intervention
ERIC Educational Resources Information Center
Snoddon, Kristin
2008-01-01
Since the beginning of the twenty-first century, the introduction in several countries of universal neonatal hearing screening programs has changed the landscape of education for deaf children. Due to the increasing provision of early intervention services for children identified with hearing loss, public education for deaf children often starts…
Nkyekyer, Joanna; Meyer, Denny; Blamey, Peter J; Pipingas, Andrew; Bhar, Sunil
2018-03-23
Sensorineural hearing loss is the most common sensory deficit among older adults. Some of the psychosocial consequences of this condition include difficulty in understanding speech, depression, and social isolation. Studies have shown that older adults with hearing loss show some age-related cognitive decline. Hearing aids have been proven as successful interventions to alleviate sensorineural hearing loss. In addition to hearing aid use, the positive effects of auditory training-formal listening activities designed to optimize speech perception-are now being documented among adults with hearing loss who use hearing aids, especially new hearing aid users. Auditory training has also been shown to produce prolonged cognitive performance improvements. However, there is still little evidence to support the benefits of simultaneous hearing aid use and individualized face-to-face auditory training on cognitive performance in adults with hearing loss. This study will investigate whether using hearing aids for the first time will improve the impact of individualized face-to-face auditory training on cognition, depression, and social interaction for adults with sensorineural hearing loss. The rationale for this study is based on the hypothesis that, in adults with sensorineural hearing loss, using hearing aids for the first time in combination with individualized face-to-face auditory training will be more effective for improving cognition, depressive symptoms, and social interaction rather than auditory training on its own. This is a crossover trial targeting 40 men and women between 50 and 90 years of age with either mild or moderate symmetric sensorineural hearing loss. Consented, willing participants will be recruited from either an independent living accommodation or via a community database to undergo a 6-month intensive face-to-face auditory training program (active control). Participants will be assigned in random order to receive hearing aid (intervention) for either the first 3 or last 3 months of the 6-month auditory training program. Each participant will be tested at baseline, 3, and 6 months using a neuropsychological battery of computer-based cognitive assessments, together with a depression symptom instrument and a social interaction measure. The primary outcome will be cognitive performance with regard to spatial working memory. Secondary outcome measures include other cognition performance measures, depressive symptoms, social interaction, and hearing satisfaction. Data analysis is currently under way and the first results are expected to be submitted for publication in June 2018. Results from the study will inform strategies for aural rehabilitation, hearing aid delivery, and future hearing loss intervention trials. ClinicalTrials.gov NCT03112850; https://clinicaltrials.gov/ct2/show/NCT03112850 (Archived by WebCite at http://www.webcitation.org/6xz12fD0B). ©Joanna Nkyekyer, Denny Meyer, Peter J Blamey, Andrew Pipingas, Sunil Bhar. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 23.03.2018.
Moodie, Sheila; Rall, Eileen; Eiten, Leisha; Lindley, George; Gordey, Dave; Davidson, Lisa; Bagatto, Marlene; Scollie, Susan
2016-03-01
There is broad consensus that screening and diagnosis of permanent hearing loss in children must be embedded within a comprehensive, evidence-based, family-centered intervention program. Clinical practice guidelines (CPGs) for pediatric hearing assessment and hearing aid verification aim to reduce variability in practice and increase the use of effective evidence-based diagnostic and treatment options so that optimal outcomes may be achieved. To be of value, guidelines must be translated and implemented into practice and ongoing monitoring of their use in practice should occur. This paper provides the results of two studies that aim to examine current pediatric audiology and amplification practice in North America. A concurrent embedded mixed methods design was used. An electronic survey was distributed to North American audiologists who delivered pediatric audiology services with 350 audiologists participating in study 1 and 63 audiologists participating in study 2. A quantitative approach was the predominant method of data collection. Respondents were prompted to provide additional qualitative text and detail regarding their quantitative response choice. This qualitative text was used during the analysis phase and combined with quantitative results to assist understanding of respondents' knowledge, skills, and barriers/facilitators to implement best practice in pediatric amplification. Approximately 70% of audiologists reported using best-practice protocols for pediatric hearing aid fitting. Despite widespread knowledge and increased use of CPGs over the last 18 yrs, results of these studies show that variation in practice patterns continue to exist. Several examples of implementation challenges are discussed with recommendations provided. In order for audiologists working with children who are deaf or hard of hearing and their families to achieve the principles of family-centered early intervention, practice guidelines must continue to be developed, disseminated, and translated as they have a positive impact on the services provided. Researchers and clinical audiologists who deliver services must continue to collaborate to understand the "how" and "why" of implementing guidelines into practice and to identify the barriers/facilitators encountered in trying to do so. American Academy of Audiology.
[Audiological characteristics of young children with otitis media with effusion].
Wang, Qiu-ju; Shi, Wei; Lan, Lan; Wang, Da-yong; Zhang, Ya-mei
2008-12-01
To characterize the audiological features in the infants with otitis media with effusion (OME) and to investigate the utility of variety of objective audiometry methods in diagnosis and intervention on OME. Fifty six infants (40 males and 16 females) were investigated, who were referred to our clinic at the General Hospital of Chinese People's Liberation Army by the other hospitals from December 2004 to June 2007 when the infants were diagnosed or highly suspected of OME. The ages at the initial diagnosis ranged from 42 days to three years, with an average of five months. The infants, after receiving the conventional otolaryngological exams, were subjected to the tests of auditory brainstem response (ABR), otoacoustic emission (OAE), tympanometry (226 Hz and 1000 Hz) and behaviors audiometry. Among 56 affected infants, 87 ears were diagnosed with OME, of which 31 infants were affected bilateral and 25 with monaural. For the 49 infants who received hearing screening at birth, 36 infants were referred at the initial screening. For the 52 infants who received repeated screening, all subjects were referred. Six infants without receiving hearing screening came to clinic when their parents observed their kids' hearing impairment. Among the 52 cases (104 ears) who received tympanometry test, 20 subjects (28 ears) showed B or C type tympanometry curve. Thirty-nine cases (78 ears) were given tympanometry test at 1000 Hz, of which 38 cases (55 ears) showed abnormal hearing. Among 56 infants (112 ears) with ABR test, 49 subjects (74 ears) exhibited prolonged ABR type I curve. All 56 infants (112 ears) received OAE test, of which 55 subjects (81 ears) were referred. Four infants (8 ears) accepted the behavior test and all of them showed A-B Gap. The combined tympanometry test at both 226 Hz and 1000 Hz, ABR latency or threshold test, infant's behavior test and OAE, used jointly, enable characterizing better OME in infants, thus helping early diagnosis of this hearing disorder.
Six year effectiveness of a population based two tier infant hearing screening programme.
Russ, S A; Rickards, F; Poulakis, Z; Barker, M; Saunders, K; Wake, M
2002-04-01
To determine whether a two tier universal infant hearing screening programme (population based risk factor ascertainment and universal distraction testing) lowered median age of diagnosis of bilateral congenital hearing impairment (CHI) >40 dB HL in Victoria, Australia. Comparison of whole population birth cohorts pre and post introduction of the Victorian Infant Hearing Screening Program (VIHSP). All babies surviving the neonatal period born in Victoria in 1989 (pre-VIHSP) and 1993 (post-VIHSP) were studied. (1) Pre-1992: distraction test at 7-9 months. (2) Post-1992: infants with risk factors for CHI referred for auditory brain stem evoked response (ABR) assessment; all others screened by modified distraction test at 7-9 months. Of the 1989 cohort (n = 63 454), 1.65/1000 were fitted with hearing aids for CHI by end 1995, compared with 2.09/1000 of the 1993 cohort (n = 64 116) by end 1999. Of these, 79 cases from the 1989 cohort (1.24/1000) and 72 cases from the 1993 cohort (1.12/1000) had CHI >40 dB HL. Median age at diagnosis of CHI >40 dB HL for the 1989 birth cohort was 20.3 months, and for the 1993 cohort was 14.2 months. Median age at diagnosis fell significantly for severe CHI but not for moderate or profound CHI. Significantly more babies with CHI >40 dB HL were diagnosed by 6 months of age in 1993 than in 1989 (21.7% v 6.3%). Compared to the six years pre-VIHSP, numbers aided by six months were consistently higher in the six years post-VIHSP (1.05 per 100 000 births versus 13.4 per 100 000 births per year). VIHSP resulted in very early diagnosis for more infants and lowered median age of diagnosis of severe CHI. However, overall results were disappointing.
Six year effectiveness of a population based two tier infant hearing screening programme
Russ, S; Rickards, F; Poulakis, Z; Barker, M; Saunders, K; Wake, M
2002-01-01
Aims: To determine whether a two tier universal infant hearing screening programme (population based risk factor ascertainment and universal distraction testing) lowered median age of diagnosis of bilateral congenital hearing impairment (CHI) >40 dB HL in Victoria, Australia. Methods: Comparison of whole population birth cohorts pre and post introduction of the Victorian Infant Hearing Screening Program (VIHSP). All babies surviving the neonatal period born in Victoria in 1989 (pre-VIHSP) and 1993 (post-VIHSP) were studied. (1) Pre-1992: distraction test at 7–9 months. (2) Post-1992: infants with risk factors for CHI referred for auditory brain stem evoked response (ABR) assessment; all others screened by modified distraction test at 7–9 months. Results: Of the 1989 cohort (n = 63 454), 1.65/1000 were fitted with hearing aids for CHI by end 1995, compared with 2.09/1000 of the 1993 cohort (n = 64 116) by end 1999. Of these, 79 cases from the 1989 cohort (1.24/1000) and 72 cases from the 1993 cohort (1.12/1000) had CHI >40 dB HL. Median age at diagnosis of CHI >40 dB HL for the 1989 birth cohort was 20.3 months, and for the 1993 cohort was 14.2 months. Median age at diagnosis fell significantly for severe CHI but not for moderate or profound CHI. Significantly more babies with CHI >40 dB HL were diagnosed by 6 months of age in 1993 than in 1989 (21.7% v 6.3%). Compared to the six years pre-VIHSP, numbers aided by six months were consistently higher in the six years post-VIHSP (1.05 per 100 000 births versus 13.4 per 100 000 births per year). Conclusions: VIHSP resulted in very early diagnosis for more infants and lowered median age of diagnosis of severe CHI. However, overall results were disappointing. PMID:11919095
Infants and Toddlers (Ages 0-3) - Raising Healthy Children
... Washing Hearing Screening Infant & Toddler Health Infant & Toddler Nutrition Maternal and Infant Health Newborn Screening Parenting Tips Perchlorate in Baby Formula Special Needs Families Test Your Knowledge about Kids’ Health Tips for Calming a Crying ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marsh, G.M.; Callahan, C.; Pavlock, D.
In 1986, the Drake Health Registry Study initiated bladder cancer screening for 366 persons at high risk because of occupational exposure to beta-naphthylamine. The Drake Health Registry Study screening protocol consists of urinalysis, Papanicolaou cytology, and quantitative fluorescence image analysis. A positive screening test qualifies participants for a full diagnostic evaluation. The screening protocol has been modified during the first 3 years of the program's existence to address unexpected patterns of test results and to incorporate advances in screening technology. The current protocol, which has a two-tiered screening schedule, has been utilized successfully for 15 months. Of the 26 positivemore » results to date most have been based on abnormal Papanicolaou cytology and/or quantitative fluorescence image analysis. Bladder abnormalities were cited among most of the 18 study members who underwent diagnostic evaluation, including chronic cystitis, inflammation, hyperplasia, and dysplasia. We conclude that the screening program is detecting very early changes in a relatively young cohort and that these persons must be monitored over a number of years to ensure adequate medical surveillance.« less
Impedance in School Screening Programs.
ERIC Educational Resources Information Center
Robarts, John T.
1985-01-01
This paper examines the controversy over use of impedance screening in public schools to identify students with hearing problems, including otitis media, a common ear condition in infants and young children. It cites research that questions the value of pure tone screening as a single test and raises critics' objections to the use of impedance,…
Jung, Eun Young; Choi, Byung Yoon; Rhee, Jihye; Park, Jaehong; Cho, Soo-Hyun; Park, Kyo Hoon
2017-02-01
To determine whether the presence of intra-amniotic infection and elevated proinflammatory cytokine levels in amniotic fluid (AF) are associated with failure in the newborn hearing screen (NHS) test in very preterm neonates. This is a retrospective cohort study of 112 premature singleton neonates born to women with preterm labor or preterm premature rupture of membranes at ≤32 wk. AF obtained through amniocentesis was cultured, and interleukin-6 (IL-6) and IL-8 levels were determined. Fourteen (12.5%) neonates failed the NHS test. The prevalence of a positive AF culture was 40% (45/112). Multiple logistic regression analyses indicated that intra-amniotic infection was significantly associated with failure in the NHS test after adjusting for baseline covariates such as maternal white blood cell count (WBC) and periventricular leukomalacia. However, the IL-6 and IL-8 levels in AF were not significantly associated with hearing screen failure. Moreover, neither gestational age at birth nor birth weight was associated with NHS failure. The presence of intra-amniotic infection, but not elevated levels of AF IL-6 and IL-8, may contribute to the risk for failure in the NHS test in very preterm neonates. This finding suggests that intra-amniotic infection in utero might contribute to the development of congenital sensorineural hearing loss.
Prevalence and causes of hearing impairment in Fundong Health District, North-West Cameroon.
Ferrite, Silvia; Mactaggart, Islay; Kuper, Hannah; Oye, Joseph; Polack, Sarah
2017-04-01
To estimate the prevalence and causes of hearing impairment in Fundong Health District, North-West Cameroon. We selected 51 clusters of 80 people (all ages) through probability proportionate to size sampling. Initial hearing screening was undertaken through an otoacoustic emission (OAE) test. Participants aged 4+ years who failed this test in both ears or for whom an OAE reading could not be taken underwent a manual pure-tone audiometry (PTA) screening. Cases of hearing impairment were defined as those with pure-tone average ≥41 dBHL in adults and ≥35 dBHL in children in the better ear, or children under age 4 who failed the OAE test in both ears. Each case with hearing loss was examined by an ear, nose and throat nurse who indicated the main likely cause. We examined 3567 (86.9%) of 4104 eligible people. The overall prevalence of hearing impairment was 3.6% (95% confidence interval [CI]: 2.8-4.6). The prevalence was low in people aged 0-17 (1.1%, 0.7-1.8%) and 18-49 (1.1%, 0.5-2.6%) and then rose sharply in people aged 50+ (14.8%, 11.7-19.1%). Among cases, the majority were classified as moderate (76%), followed by severe (15%) and profound (9%). More than one-third of cases of hearing impairment were classified as unknown (37%) or conductive (37%) causes, while sensorineural causes were less common (26%). Prevalence of hearing impairment in North-West Cameroon is in line with the WHO estimate for sub-Saharan Africa. The majority of cases with known causes are treatable, with impacted wax playing a major role. © 2017 John Wiley & Sons Ltd.
Swanepoel, De Wet; Eikelboom, Robert H; Hunter, Michael L; Friedland, Peter L; Atlas, Marcus D
2013-06-01
The baby boomer population will become high users of the health-care system in coming years. Self-report of hearing loss at a primary health-care visit may offer timely referrals to audiological services, but there has been no population-based study of self-reported hearing loss in the baby boomer generation. To determine the clinical value and audiometric correspondence of self-reported hearing loss as a screening tool for the baby boomer population. A population-based study, Busselton Healthy Ageing Study (BHAS), surveying baby boomers born between 1946 and 1964 from the shire of Busselton, Western Australia. A randomized sample of noninstitutionalized baby-boomers listed on the electoral roll (n = 6690) and resident in the shire are eligible to participate. This study reports on data from the first 1004 attendees (53.5% female) with a mean age of 56.23 (SD = 5.43). Data from a self-report question on hearing loss and diagnostic pure tone audiometry was utilized for this study. Analysis included screening performance measures of self-report compared to audiometric cut-offs, receiver operator curve (ROC) to determine optimal level, analysis of variance to compare hearing status to self-report, and binary logistic regression to determine best audiometric predictors. Of the sample, 16% self-reported hearing loss (72.1% males). Logistic regression indicated 4000 Hz as the most important individual frequency related to self-report while the four-frequency average (500, 1000, 2000, and 4000 Hz) >25 dB in the worse ear was the most significant averaged cutoff with 68% sensitivity and 87% specificity. Of those who self-reported a hearing loss, 80% had either a four-frequency average hearing loss >25 dB in the worse ear or a high-frequency average (4000 and 8000 Hz) hearing loss greater than 35 dB in the worse ear. Baby boomer adults who self-report hearing impairment on direct inquiry are most likely to have a hearing loss. A simple question at a primary health care visit may facilitate a timely referral for audiological services in a baby boomer adult, who may be more amenable to rehabilitation. American Academy of Audiology.
Audiovestibular consequences of congenital cytomegalovirus infection.
Teissier, N; Bernard, S; Quesnel, S; Van Den Abbeele, T
2016-12-01
Congenital cytomegalovirus (CMV) infection is the second most frequent cause of mental retardation and sensorineural hearing loss, after genetic factors. Recently, pediatric forensic and fetopathological studies have led to progress in understanding the pathophysiological mechanisms underlying the various neurosensory sequelae. Thanks to the identification of certain prognostic factors of hearing loss, therapeutic protocols based on antiviral molecules are now proposed for target populations. This treatment has shown efficacy in limiting hearing threshold deterioration and even, in some cases, seems to provide partial recovery of hearing in symptomatic congenitally infected CMV neonates. However, optimal treatment duration and administration modalities are not clearly defined. This article reviews recent data concerning audiovestibular sequelae and their management in children congenitally infected by CMV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Baltussen, Rob; Smith, Andrew
2012-03-02
To determine the relative costs, effects, and cost effectiveness of selected interventions to control cataract, trachoma, refractive error, hearing loss, meningitis and chronic otitis media. Cost effectiveness analysis of or combined strategies for controlling vision and hearing loss by means of a lifetime population model. Two World Health Organization sub-regions of the world where vision and hearing loss are major burdens: sub-Saharan Africa and South East Asia. Biological and behavioural parameters from clinical and observational studies and population based surveys. Intervention effects and resource inputs based on published reports, expert opinion, and the WHO-CHOICE database. Cost per disability adjusted life year (DALY) averted, expressed in international dollars ($Int) for the year 2005. Treatment of chronic otitis media, extracapsular cataract surgery, trichiasis surgery, treatment for meningitis, and annual screening of schoolchildren for refractive error are among the most cost effective interventions to control hearing and vision impairment, with the cost per DALY averted <$Int285 in both regions. Screening of both schoolchildren (annually) and adults (every five years) for hearing loss costs around $Int1000 per DALY averted. These interventions can be considered highly cost effective. Mass treatment with azithromycin to control trachoma can be considered cost effective in the African but not the South East Asian sub-region. Vision and hearing impairment control interventions are generally cost effective. To decide whether substantial investments in these interventions is warranted, this finding should be considered in relation to the economic attractiveness of other, existing or new, interventions in health.
Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva
2016-07-01
The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.
Neuro-rehabilitation Approach for Sudden Sensorineural Hearing Loss
Sekiya, Kenichi; Fukushima, Munehisa; Teismann, Henning; Lagemann, Lothar; Kakigi, Ryusuke; Pantev, Christo; Okamoto, Hidehiko
2016-01-01
Sudden sensorineural hearing loss (SSHL) is characterized by acute, idiopathic hearing loss. The estimated incidence rate is 5-30 cases per 100,000 people per year. The causes of SSHL and the mechanisms underlying SSHL currently remain unknown. Based on several hypotheses such as a circulatory disturbance to the cochlea, viral infection, and autoimmune disease, pharmaco-therapeutic approaches have been applied to treat SSHL patients; however, the efficacy of the standard treatment, corticosteroid therapy, is still under debate. Exposure to intense sounds has been shown to cause permanent damage to the auditory system; however, exposure to a moderate level enriched acoustic environment after noise trauma may reduce hearing impairments. Several neuroimaging studies recently suggested that the onset of SSHL induced maladaptive cortical reorganization in the human auditory cortex, and that the degree of cortical reorganization in the acute SSHL phase negatively correlated with the recovery rate from hearing loss. This article reports the development of a novel neuro-rehabilitation approach for SSHL, "constraint-induced sound therapy (CIST)". The aim of the CIST protocol is to prevent or reduce maladaptive cortical reorganization by using an enriched acoustic environment. The canal of the intact ear of SSHL patients is plugged in order to motivate them to actively use the affected ear and thereby prevent progress of maladaptive cortical reorganization. The affected ear is also exposed to music via a headphone for 6 hr per day during hospitalization. The CIST protocol appears to be a safe, easy, inexpensive, and effective treatment for SSHL. PMID:26863274
Intelligence and Academic Achievement With Asymptomatic Congenital Cytomegalovirus Infection.
Lopez, Adriana S; Lanzieri, Tatiana M; Claussen, Angelika H; Vinson, Sherry S; Turcich, Marie R; Iovino, Isabella R; Voigt, Robert G; Caviness, A Chantal; Miller, Jerry A; Williamson, W Daniel; Hales, Craig M; Bialek, Stephanie R; Demmler-Harrison, Gail
2017-11-01
To examine intelligence, language, and academic achievement through 18 years of age among children with congenital cytomegalovirus infection identified through hospital-based newborn screening who were asymptomatic at birth compared with uninfected infants. We used growth curve modeling to analyze trends in IQ (full-scale, verbal, and nonverbal intelligence), receptive and expressive vocabulary, and academic achievement in math and reading. Separate models were fit for each outcome, modeling the change in overall scores with increasing age for patients with normal hearing ( n = 78) or with sensorineural hearing loss (SNHL) diagnosed by 2 years of age ( n = 11) and controls ( n = 40). Patients with SNHL had full-scale intelligence and receptive vocabulary scores that were 7.0 and 13.1 points lower, respectively, compared with controls, but no significant differences were noted in these scores among patients with normal hearing and controls. No significant differences were noted in scores for verbal and nonverbal intelligence, expressive vocabulary, and academic achievement in math and reading among patients with normal hearing or with SNHL and controls. Infants with asymptomatic congenital cytomegalovirus infection identified through newborn screening with normal hearing by age 2 years do not appear to have differences in IQ, vocabulary or academic achievement scores during childhood, or adolescence compared with uninfected children. Copyright © 2017 by the American Academy of Pediatrics.
Merugumala, Sri Vamshi; Pothula, Vijay; Cooper, Max
2017-10-01
In low income countries, deaf children are identified late due to the absence of a universal screening. Hearing impairment is a common yet neglected disability in India that leads to loss of speech and language. This qualitative study explored barriers to accessing appropriate hearing services in one city in southern India. To identify the barriers in timely management of deafness, 25 semi-structured interviews were conducted. Data were examined using Applied Thematic Analysis. Seventeen mothers of deaf children, primarily from low socioeconomic backgrounds, and eight staff members at a charitable hearing centre in Hyderabad. Barriers to accessing hearing services included failure to recognise deafness, the dominant role of elders in household decisions, belief that deafness would resolve, reassurance from a child's overall good health, lack of funds and transportation barriers to reach the centre particularly from rural areas. Parents frequently learned about services through word of mouth. The challenges to accessing appropriate services for deafness operate prior to presentation and include educational, cultural, navigational and financial barriers especially for those of lower socioeconomic status and residents of rural areas. The findings highlighted the need to raise awareness and implement wider screening programmes for early interventions.
Mulwafu, Wakisa; Kuper, Hannah; Viste, Asgaut; Goplen, Frederik K
2017-10-11
To assess the feasibility and acceptability of training community health workers (CHWs) in ear and hearing care, and their ability to identify patients with ear and hearing disorders. Cluster randomised controlled trial (RCT). Health centres in Thyolo district, Malawi. Ten health centres participated, 5 intervention (29 CHWs) and 5 control (28 CHWs). Intervention CHWs received 3 days of training in primary ear and hearing care, while among control CHWs, training was delayed for 6 months. Both groups were given a pretest that assessed knowledge about ear and hearing care, only the intervention group was given the posttest on the third day of training. The intervention group was given 1 month to identify patients with ear and hearing disorders in their communities, and these people were screened for hearing disorders by ear, nose and throat clinical specialists. Primary outcome measure was improvement in knowledge of ear and hearing care among CHWs after the training. Secondary outcome measures were number of patients with ear or hearing disorders identified by CHWs and number recorded at health centres during routine activities, and the perceived feasibility and acceptability of the intervention. The average overall correct answers increased from 55% to 68% (95% CI 65 to 71) in the intervention group (p<0.001). A total of 1739 patients with potential ear and hearing disorders were identified by CHWs and 860 patients attended the screening camps, of whom 400 had hearing loss (73 patients determined through bilateral fail on otoacoustic emissions, 327 patients through audiometry). Where cause could be determined, the most common cause of ear and hearing disorders was chronic suppurative otitis media followed by impacted wax. The intervention was perceived as feasible and acceptable to implement. Training was effective in improving the knowledge of CHW in ear and hearing care in Malawi and allowing them to identify patients with ear and hearing disorders. This intervention could be scaled up to other CHWs in low-income and middle-income countries. Pan African Clinical Trial Registry (201705002285194); Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Alanazi, Ahmad A; Nicholson, Nannette; Atcherson, Samuel R; Franklin, Clifford; Anders, Michael; Nagaraj, Naveen; Franklin, Jennifer; Highley, Patricia
2016-09-01
The primary purpose of this study was to test the effect of the combined use of trained standardized parents and a baby simulator on students' hearing screening and parental counseling knowledge and skills. A one-group pretest-posttest quasi-experimental study design was used to assess self-ratings of confidence in knowledge and skills and satisfaction of the educational experience with standardized parents and a baby simulator. The mean age of the 14 audiology students participating in this study was 24.79 years (SD = 1.58). Participants completed a pre- and postevent questionnaire in which they rated their level of confidence for specific knowledge and skills. Six students (2 students in each scenario) volunteered to participate in the infant hearing screening and counseling scenarios, whereas others participated as observers. All participants participated in the briefing and debriefing sessions immediately before and after each of 3 scenarios. After the last scenario, participants were asked to complete a satisfaction survey of their learning experience using simulation and standardized parents. Overall, the pre- and post-simulation event questionnaire revealed a significant improvement in the participants' self-rated confidence levels regarding knowledge and skills. The mean difference between pre- and postevent scores was 0.52 (p < .01). The mean satisfaction level was 4.71 (range = 3.91-5.00; SD = 0.30) based on a Likert scale, where 1 = not satisfied and 5 = very satisfied. The results of this novel educational activity demonstrate the value of using infant hearing screening and parental counseling simulation sessions to enhance student learning. In addition, this study demonstrates the use of simulation and standardized parents as an important pedagogical tool for audiology students. Students experienced a high level of satisfaction with the learning experience.
Chiong, Charlotte M; Llanes, Erasmo Gonzalo Dv; Tirona-Remulla, Agnes N; Calaquian, Christopher Malorre E; Reyes-Quintos, Maria-Rina T
2003-01-01
To determine pass and refer rates, and identify risk factors relating to refer responses, in neonates screened using distortion-product otoacoustic emissions (DPOAEs). A total of 435 neonates admitted to the neonatal intensive care unit (NICU) of the Philippine General Hospital between May and October 2000 were screened using DPOAEs within 48 h of admission. The male:female ratio in the sample was 1.05. In total, 56% of neonates were born preterm, the mean birthweight was 2,428.39 +/- 710.39 g and 8.9% weighed < 1,500 g. In total, 47.9% were delivered by Caesarian section and 44.9% were delivered vaginally. Almost 14% of neonates had 1-min Apgar scores of < 6, and 4% had 5-min Apgar scores of < 7. Approximately 95% of neonates had a poor perinatal history. Using pediatric aging it was noted that 46% of these neonates were born preterm. and 30.4% were small for gestational age. At least one neonatal disease was found in 42% of neonates, whilst 95.7% had to be given medication. The bilateral refer rate was 29.1%. Two-by-two analysis of risk factors for hearing loss and DPOAE measurements showed that only male sex seemed to have a significant association with a refer response. Neonates weighing < 1,500 g at birth showed a marginally significant association with a refer response (p = 0.07). All other neonates showed no crude association with DPOAE measurements. These preliminary data show that a high proportion of NICU patients may have poor outer hair cell function, and thus poor hearing. In order to develop an effective neonatal hearing screening program, further studies of prevalence and risk factors should be pursued in the same setting.
Bergevin, Anna; Zick, Cathleen D; McVicar, Stephanie Browning; Park, Albert H
2015-12-01
In this study, we estimate an ex ante cost-benefit analysis of a Utah law directed at improving early cytomegalovirus (CMV) detection. We use a differential cost of treatment analysis for publicly insured CMV-infected infants detected by a statewide hearing-directed CMV screening program. Utah government administrative data and multi-hospital accounting data are used to estimate and compare costs and benefits for the Utah infant population. If antiviral treatment succeeds in mitigating hearing loss for one infant per year, the public savings will offset the public costs incurred by screening and treatment. If antiviral treatment is not successful, the program represents a net cost, but may still have non-monetary benefits such as accelerated achievement of diagnostic milestones. The CMV education and treatment program costs are modest and show potential for significant cost savings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Fish in a Dish: Drug Discovery for Hearing Habilitation.
Esterberg, Robert; Coffin, Allison B; Ou, Henry; Simon, Julian A; Raible, David W; Rubel, Edwin W
2013-01-01
The majority of hearing loss is caused by the permanent loss of inner ear hair cells. The identification of drugs that modulate the susceptibility to hair cell loss or spur their regeneration is often hampered by the difficulties of assaying for such complex phenomena in mammalian models. The zebrafish has emerged as a powerful animal model for chemical screening in many contexts. Several characteristics of the zebrafish, such as its small size and external location of sensory hair cells, uniquely position it as an ideal model organism for the study of hair cell toxicity, protection, and regeneration. We have used this model to screen for drugs that affect each of these aspects of hair cell biology and have identified compounds that affect each of these processes. The identification of such drugs and drug-like compounds holds promise in the future ability to stem hearing loss in the human population.
Parent educational materials regarding the newborn hearing screening process.
Krishnan, Lata A; Lawler, Breanne; Van Hyfte, Shannon
2017-04-01
Newborn hearing screening (NHS) procedures and implementation vary from state to state in the US. The purpose of this study was to evaluate the content and nature of information provided to parents about their infant's NHS across states to answer two questions: 1) what information is included in each state's parent information brochure? and 2) do the brochures include educational information requested by parents that may help reduce parental anxiety, improve satisfaction, and decrease the potential for misunderstandings? Each state's parent brochures and educational resources provided to parents were accessed via the National Center for Hearing Assessment and Management (NCHAM) website, categorized, and reviewed for content. Results indicate that the information provided to parents varies considerably across states and many brochures do not contain important information that is desired by parents. NHS procedures may be improved by providing standardized information regarding the process to parents in all states. Copyright © 2017 Elsevier B.V. All rights reserved.
Identification of Childhood Disability in Jamaica: Evaluation of the Ten Question Screen.
ERIC Educational Resources Information Center
Thorburn, Marigold; And Others
1992-01-01
This study examined the internal validity and reasons for false positives for the Ten Question Screen (with and without probes), used by community workers in developing nations to assess type and severity of disability. Results support the use of the screen but only if paired with measurements of hearing and visual impairments. (DB)
Optimizing otoacoustic emission protocols for a UNHS program.
Hatzopoulos, S; Petruccelli, J; Ciorba, A; Martini, A
2009-01-01
To identify the optimal test protocol to screen for hearing problems in newborns, an evaluation of three distortion product otoacoustic emission (DPOAE) protocols was conducted in neonates, from a well-baby nursery (WBN) and from a neonatal intensive care unit (NICU) and compared to the performance in newborns of a more standard protocol based on transient-evoked OAEs (TEOAEs). The DPOAE protocols used asymmetrical stimulus intensities (L(1) > L(2)) with a frequency ratio of 1.22, in the following format: (P1), L(1) = 60, L(2) = 50 dB SPL; (P2), L(1) = 65, L(2) = 55 dB SPL, and (P3), L(1) = 75, L(2) = 65 dB SPL. Linear TEOAE responses, evoked by click stimuli of 75 dB peSPL, were used as controls of normal cochlear function. Five frequencies at 1.5, 2.0, 3.0, 4.0 and 5.0 kHz were tested with a common commercially available macro-based software subroutine (Otodynamics Corp, ILO-92). The project evaluated the responses from 1200 WBN infants (average age 48 h) and 350 low-birth-weight NICU infants, all randomly selected. Statistical analyses comparing the signal-to-noise ratios (S/N), at the predefined f(2) frequencies, indicated that the P1 and P2 DPOAE protocols generated similar responses. Significant S/N differences were observed in the P3 to P2 dataset comparisons. DPOAE scoring criteria were estimated from the P3 dataset using a one-sided, distribution-free confidence intervals. The scoring criteria for a 'pass' were estimated as a minimum S/N of 6.0, 7.0 and 6.0 dB at 2.0, 3.0 and 4.0 kHz, respectively. In terms of feasibility, the P3 protocol generated responses in 98% of the WBN and 94.8% of the NICU infants. All three DPOAE protocols demonstrated shorter time-recording requirements than the standard TEOAE test. The false-positive and false-negative rates for the NICU infants were estimated as 0.0028 and 0.003%, respectively.
Preliminary Outcomes Report for CO2 Laser Assisted Electric-Acoustic Cochlear Implantation.
Stevens, Shawn M; Redmann, Andrew; Whitaker, Kayla; Ruotanen, Alyson; Houston, Lisa; Hammer, Theresa; Samy, Ravi N
2018-06-01
Report on the safety/efficacy of a novel, carbon dioxide (CO2) laser-assisted protocol for hearing-preservation cochlear implantation (HPCI) and electric-acoustic stimulation (EAS). Retrospective case review. Tertiary referral center. Adult patients meeting established criteria for HPCI and EAS. Therapeutic/rehabilitative. A standardized protocol used CO2 laser to achieve meticulous hemostasis and perform cochleostomy was evaluated. Audiometric assessments included low-tone pure tone average (LtPTA), consonant-nucleus-consonant (CNC), and AzBio scores. Primary outcomes were low-tone hearing-preservation (LtHP) and EAS usage rates. Secondary outcomes included change in LtPTA, outcomes durability, and the rate/onset/presentation of delayed hearing loss (DHL). Subset analyses stratified data by presenting LtPTA and surgeon experience. Forty-seven patients and 52 ears were included. Mean follow-up was 20.7 ± 12.6 months. When adjusted for preoperative LtPTA less than 60 dB, the LtHP rate was 77%. This was significantly better than for patients with LtPTA more than 60 dB (24%; p < 0.0001). Outcomes were highly durable. EAS usage was excellent in those with LtPTA less than 60 dB (100%). Nine patients developed DHL. Three additional patients (25%) were successfully salvaged via steroids. Both CNC and AzBio scores improved significantly (p < 0.0001) at definitive testing. Speech-hearing scores did not differ significantly between patients using/not using EAS. The complication rate was 3.8%; none were caused by the laser. Surgeon experience was associated with significantly better outcomes. Use of a CO2 laser-assisted HPCI protocol was safe and effective. Outcomes were consistent with contemporary literature reporting. Patient selection and surgeon experience both significantly impacted outcomes.
(De)stigmatizing the silent epidemic: representations of hearing loss in entertainment television.
Foss, Katherine A
2014-01-01
The number of adolescents, young adults, and senior citizens experiencing hearing loss has significantly increased over the last 30 years. Despite this prevalence, hearing loss receives little attention in popular and political discourse, except in its connection to aging. Thus, hearing loss and the use of hearing aids have been stigmatized, discouraging adults from seeking hearing evaluation and screening, and justifying the lack of insurance coverage for hearing devices. This research explored how and why hearing loss continues to be stigmatized through a study of media messages about hearing loss. A textual analysis was conducted on 276 television episodes that involved d/Deaf characters and/or storylines about hearing loss and deafness from 1987 through 2013 (see Table 1). Only 11 fictional programs addressed the experience of hearing loss through 47 episodes, including Criminal Minds, Switched at Birth, House, M.D., and New Girl. Contrary to the assumption that hearing loss exclusively impacts older people, characters were typically young, attractive, working professionals who held prominent roles in the programs. For most characters, hearing loss developed suddenly and was restored by the end of the episode, with only four characters using hearing aids. Hearing loss was depicted as comical, embarrassing, lonely, and threatening to one's work. The scarcity of hearing loss portrayals, combined with the negative representations of hearing loss, could help explain why hearing loss continues to be stigmatized and overlooked, even though almost half of all Americans will eventually experience difficulty hearing.
Evaluation of Hydroxyatrazine in the Endocrine Disruptor Screening and Testing Program’s Male and Female Pubertal Protocols. ABSTRACT Two critical components of the validation of any in vivo screening assay are to demonstrate sensitivity (ability to detect weak endocrine ...
Almontashiri, Naif A M; Alswaid, Abdulrahman; Oza, Andrea; Al-Mazrou, Khalid A; Elrehim, Omnia; Tayoun, Ahmad Abou; Rehm, Heidi L; Amr, Sami S
2018-01-01
Purpose Hearing loss is more prevalent in the Saudi Arabian population than in other populations; however, the full range of genetic etiologies in this population is unknown. We report the genetic findings from 33 Saudi hearing-loss probands of tribal ancestry, with predominantly prelingual severe to profound hearing loss. Methods Testing was performed over the course of 2012–2016, and involved initial GJB2 sequence and GJB6-D13S1830 deletion screening, with negative cases being reflexed to a next-generation sequencing panel with 70, 71, or 87 hearing-loss genes. Results A “positive” result was reached in 63% of probands, with two recurrent OTOF variants (p.Glu57* and p.Arg1792His) accountable for a third of all “positive” cases. The next most common cause was pathogenic variants in MYO7A and SLC26A4, each responsible for three “positive” cases. Interestingly, only one “positive” diagnosis had a DFNB1-related cause, due to a homozygous GJB6-D13S1830 deletion, and no sequence variants in GJB2 were detected. Conclusion Our findings implicate OTOF as a potential major contributor to hearing loss in the Saudi population, while highlighting the low contribution of GJB2, thus offering important considerations for clinical testing strategies for Saudi patients. Further screening of Saudi patients is needed to characterize the genetic spectrum in this population. PMID:29048421
Apps for Hearing Science and Care.
Paglialonga, Alessia; Tognola, Gabriella; Pinciroli, Francesco
2015-09-01
Our research aims at the identification and assessment of applications (referred to as apps) in the hearing health care domain. This research forum article presents an overview of the current availability, affordability, and variety of hearing-related apps. The available apps were reviewed by searching on the leading platforms (iOS, Android, Windows Phone stores) using the keywords hearing, audiology, audio, auditory, speech, language, tinnitus, hearing loss, hearing aid, hearing sys tem, cochlear implant, implantable device, auditory training, hearing rehabilitation, and assistive technology/tool/device. O n the bas is of the offered services, apps were classified into 4 application domains: (a) screening and assessment, (b) intervention and rehabilitation, (c) education and information, and (d) assistive tools. A large variety of apps are available in the hearing health care domain. These cover a wide range of services for people with hearing or communication problems as well as for hearing professionals, families, or informal caregivers. This evolution can potentially bring along considerable advantages and improved outcomes in the field of hearing health care. Nevertheless, potential risks and threats (e.g., safety, quality, effectiveness, privacy, and regulation) should not be overlooked. Significant research—particularly in terms of assessment and guidance—is still needed for the informed, aware, and safe adoption of hearing-related apps by patients and professionals.
The Need for Improved Detection and Management of Adult-Onset Hearing Loss in Australia
McMahon, Catherine M.; Gopinath, Bamini; Schneider, Julie; Reath, Jennifer; Hickson, Louise; Leeder, Stephen R.; Mitchell, Paul; Cowan, Robert
2013-01-01
Adult-onset hearing loss is insidious and typically diagnosed and managed several years after onset. Often, this is after the loss having led to multiple negative consequences including effects on employment, depressive symptoms, and increased risk of mortality. In contrast, the use of hearing aids is associated with reduced depression, longer life expectancy, and retention in the workplace. Despite this, several studies indicate high levels of unmet need for hearing health services in older adults and poor use of prescribed hearing aids, often leading to their abandonment. In Australia, the largest component of financial cost of hearing loss (excluding the loss of well-being) is due to lost workplace productivity. Nonetheless, the Australian public health system does not have an effective and sustainable hearing screening strategy to tackle the problem of poor detection of adult-onset hearing loss. Given the increasing prevalence and disease burden of hearing impairment in adults, two key areas are not adequately met in the Australian healthcare system: (1) early identification of persons with chronic hearing impairment; (2) appropriate and targeted referral of these patients to hearing health service providers. This paper reviews the current literature, including population-based data from the Blue Mountains Hearing Study, and suggests different models for early detection of adult-onset hearing loss. PMID:23710184
Real-Time Transliteration of Speech into Print for Hearing-Impaired Students in Regular Classes.
ERIC Educational Resources Information Center
Stuckless, E. Ross
1983-01-01
A system is described whereby a stenotypist records the classroom instructor's and students' speech which a computer then translates to words on the screen for hearing impaired postsecondary students. Initial results include a high degree of verbatim accuracy, support for real-time operation, and several technical problems including lack of…
Predictors of Early-Onset Permanent Hearing Loss in Malnourished Infants in Sub-Saharan Africa
ERIC Educational Resources Information Center
Olusanya, Bolajoko O.
2011-01-01
The objective of this study was to determine the predictors of early-onset permanent hearing loss (EPHL) among undernourished infants in a low-income country where routine screening for developmental disabilities in early childhood is currently unattainable. All infants attending four community-based clinics for routine immunization who met the…
Language Planning for the 21st Century: Revisiting Bilingual Language Policy for Deaf Children
ERIC Educational Resources Information Center
Knoors, Harry; Marschark, Marc
2012-01-01
For over 25 years in some countries and more recently in others, bilingual education involving sign language and the written/spoken vernacular has been considered an essential educational intervention for deaf children. With the recent growth in universal newborn hearing screening and technological advances such as digital hearing aids and…
Future Directions for EHDI Programs: Recommendations from a Strategic Analysis
ERIC Educational Resources Information Center
Bradham, Tamala S.; Houston, K. Todd
2011-01-01
Over the past 20 years, tremendous strides have been made in establishing and strengthening early hearing detection and intervention (EHDI) programs in all 50 states and the U.S. territories. Although EHDI programs have become more robust, considerable work remains to ensure that all children who do not pass a hearing screening receive the…
The Roller-Coaster of Experiences: Becoming the Parent of a Deaf Child
ERIC Educational Resources Information Center
Bosteels, Sigrid; Van Hove, Geert; Vandenbroeck, Michel
2012-01-01
When early testing indicates a hearing loss, parents find themselves on a roller-coaster of experiences leaving little time or space for reflection. This study is based on interviews with families in the Flemish region of Belgium, one of the earliest in the world to introduce universal neonatal screening for hearing loss. Starting from a…
Fang, Xingang; Li, Xi; Zhang, Qi; Wan, Jin; Sun, Mei; Chang, Fengshui; Lü, Jun; Chen, Gang
2016-11-01
By comparing the Universal Neonatal Hearing Screening (UNHS) program as implemented in Shanghai and other regions in China and countries around the world, this study makes an assessment of the Shanghai model and summarizes the experiences implementing the UNHS program, so as to provide a valuable reference for other countries or regions to carry out UNHS more effectively. Since Shanghai is one of the most developed regions in China, we also examined the relationship between economic development and the UNHS starting year and coverage rate. The study conducted a systematic review of published studies in Chinese and English on the program status of neonatal hearing screening to compare and analyze the implementation of the UNHS program in 20 cities or provinces in China and 24 regions or countries around the world. The literature search in Chinese was conducted in the three most authoritative publication databases, CNKI (China National Knowledge Infrastructure), WANFANGDATA, and CQVIP (http://www.cqvip.com/). We searched all publications in those databases with the keywords "neonatal hearing screening" (in Chinese) between 2005 and 2014. English literature was searched using the same keywords (in English). The publication database included Medline and Web of Science, and the search time period was 2000-2014. Shanghai was one of the first regions in China to implement UNHS, and its coverage rate was among the top regions by international comparison. The starting time of the UNHS program had no relationship with the Gross Domestic Product (GDP) per capita in the same year. Economic level serves as a threshold for carrying out UNHS but is not a linear contributor to the exact starting time of such a program. The screening coverage rate generally showed a rising trend with the increasing GDP per capita in China, but it had no relationship with the area's GDP per capita in selected regions and countries around the world. The system design of UNHS is the key factor influencing screening coverage. Policy makers, program administrators, and cost-sharing structures are important factors that influence the coverage rates of UNHS. When to carry out a UNHS program is determined by the willingness and preference of the local government, which is influenced by the area's social, political and cultural conditions. Mandatory hearing screening and minimal-cost to no-cost intervention are two pillars for a good coverage rate of UNHS. In terms of system design, decision-making, implementation, funding and the concrete implementation plan are all important factors affecting the implementation of the UNHS. Copyright © 2016 The Author(s). Published by Elsevier Ireland Ltd.. All rights reserved.
McMahon, Catherine M; Schneider, Julie; Dunsmore, Moira; Gopinath, Bamini; Kifley, Annette; Mitchell, Paul; Wang, Jie-Jin; Leeder, Stephen R
Combined vision and hearing impairment, termed dual sensory impairment (DSI), is associated with poorer health outcomes compared with a single sensory loss alone. Separate systems of care exist for visual and hearing impairment which potentially limit the effectiveness of managing DSI. To address this, a Hearing Screening Education Model (HSEM) was offered to older adults attending a low-vision clinic in Australia within this pilot study. The present study aimed to evaluate the benefits of seeking help on hearing handicap, self-perceived health, and use of community services among those identified with unmet hearing needs after participation in the HSEM. Of 210 older adults (>55 years of age) who completed the HSEM and were referred for follow-up, 169 returned for a follow-up interview at least 12 months later. Of these, 68 (40.2%) sought help, and the majority were seen by a hearing healthcare provider (89.7%). Changes in hearing handicap, quality of life, and reliance on community services between the baseline and 12-month follow-up were compared between those who sought help and those who did not. In addition, the perceived value of the HSEM was assessed. Results showed that there was no significant difference in hearing handicap between those who sought help (mean change -1.02 SD = 7.97, p = 0.3) and those who did not (mean change 0.94 SD = 7.68, p = 0.3), p = 0.18. The mental component of the SF-36 worsened significantly between baseline and follow-up measures across the whole group (mean change -2.49 SD = 9.98, p = 0.002). This was largely driven by those not seeking help, rather than those seeking help, but was not significantly different between the two groups. Those who sought help showed a significant reduction in the use of community services compared with those who did not. Further, all participants positively viewed the HSEM's underlying principle of greater integration between vision and hearing services. These findings suggest a need to further develop and evaluate integrated models of healthcare for older adults with DSI. It also highlights the importance of using broader measures of benefit, other than use of hearing aids to evaluate outcomes of hearing healthcare programs.
Health care screening for people with mental handicap living in the community.
Wilson, D N; Haire, A
1990-01-01
OBJECTIVE--To determine what contact people with mental handicap had had with their general practitioner in the previous year; what prescribed drugs they were taking and whether these had been reviewed; when hearing and vision had last been screened; and what medical problems were found on examination. DESIGN--Case series. SETTING-Day centre for adults with mental handicap. SUBJECTS--A balanced sample of 75 of the 150 people attending the day centre. 10 Were excluded because consent was not given. RESULTS--The subjects did not consult their general practitioners more frequently than the general population but were more likely to be taking prescribed drugs, and 57% of these prescriptions had not been reviewed by a doctor. Thirty three people failed vision screening, including 13 who wore glasses. Twenty seven of the 62 who were testable had a hearing impairment. CONCLUSIONS--As only eight out of 65 people examined in the study did not have an appreciable problem brought to light, screening seems to be worth while. Whether such screening needs to be done by a medically qualified person needs further research. PMID:2148703
Evaluation of the localization auditory screening test in children 6-18 months of age.
Tillis, C H; Grimm, W A
1978-01-01
The present paper is a report of a project to develop an automated auditory screening test for infants six to 18 months of age. The first year of the project was devoted to developing equipment and test procedures; the second year was concerned with testing the effectiveness of the equipment and procedures on an actual population of six to 18 month old infants. Two-hundred and fifty infants were screened auditorily as part of a county health department child development clinic. The pass/fail results of the screening test were evaluated in terms of physical and developmental examination following the screening and by means of a case review of the child's previous history. The results indicate that the procedure under investigation can be used to differentiate the normal hearing infant from the infant with possible hearing problems. It is shown by the test environment in which this study was conducted that the procedure reported can be successfully incorporated into a public health program, i.e., child development clinics or EPSDT programs.
Sato, Teruyuki; Nakazawa, Misao; Takahashi, Shin; Ishikawa, Kazuo
2013-06-01
The dissemination of newborn hearing screening has detected children with mild-moderate hearing impairment at an early age. However, there is no nation-wide welfare system for children with mild-moderate hearing impairment in Japan. Under these kinds of social conditions, a subsidized project of hearing aid purchase for mild-moderate hearing impaired children has come into force from April 2010 in Akita prefecture. All 18 candidates who applied for this project were subsidized in Akita prefecture. Eighteen children purchased their hearing aids using this subsidy. The feature of this project was that every child could have access to subsidies as long as their doctor recognized the effectiveness of hearing aids because children with hearing impairment need to learn language. They contacted the hospital, prefectural government and institutes related to hearing loss before this project come into force. We recognized parents who are raising a child with mild-moderate hearing impairment have high interest in this project. Hearing aids can represent a considerable expense for young parents who are raising a child. We encountered some children who had to give up the idea of hearing aids due to their parents' economic circumstances before this project become effective. These situations were completely avoided after this project came into being. This administrative purpose was of demonstrated value in children with mild-moderate hearing impairment.
NASA Astrophysics Data System (ADS)
Polgár, Tímea; Menyhárd, Dóra K.; Keserű, György M.
2007-09-01
An effective virtual screening protocol was developed against an extended active site of CYP2C9, which was derived from X-ray structures complexed with flubiprofen and S-warfarin. Virtual screening has been effectively supported by our structure-based pharmacophore model. Importance of hot residues identified by mutation data and structural analysis was first estimated in an enrichment study. Key role of Arg108 and Phe114 in ligand binding was also underlined. Our screening protocol successfully identified 76% of known CYP2C9 ligands in the top 1% of the ranked database resulting 76-fold enrichment relative to random situation. Relevance of the protocol was further confirmed in selectivity studies, when 89% of CYP2C9 ligands were retrieved from a mixture of CYP2C9 and CYP2C8 ligands, while only 22% of CYP2C8 ligands were found applying the structure-based pharmacophore constraints. Moderate discrimination of CYP2C9 ligands from CYP2C18 and CYP2C19 ligands could also be achieved extending the application domain of our virtual screening protocol for the entire CYP2C family. Our findings further demonstrate the existence of an active site comprising of at least two binding pockets and strengthens the need of involvement of protein flexibility in virtual screening.
Evaluation of Extended-wear Hearing Aid Technology for Operational Military Use
2015-07-01
AFRL), Battlespace Acoustics Branch has been updated and approved to include the Lyric device. The AFRL protocol was sent to the Human Research...Jackson Foundation for the Advancement of Military Medicine Battlespace Acoustics Branch AFRL Wright-Patterson AFB, OH 45433 elizabeth_anne.mckenna.1...just after Hearing Aid 10 Drive speaker Incased in Foam 11 3.0 MEASUREMENTS PERFORMED 3.1 RE102 - Radiated Emissions, Electric Field, 2 MHz to 18
Phase 3 Clinical Trials: D-Methionine to Reduce Noise-Induced Hearing Loss
2013-03-01
tympanometry, and pure-tone hearing threshold testing at .5, 1, 2, 3, 4, 6, 8 kHz bilaterally. Tinnitus will be measured using standardized ...chemistry, and urinalysis ) on all study participants. The purpose of these recommendations were 1) to exclude participants with mild renal impairment until...analysis and urinalysis for the study participants to the study protocol. Therefore, during the third quarter, no additions were made to the original
Jonker, Dirk; Gustafsson, Ewa; Rolander, Bo; Arvidsson, Inger; Nordander, Catarina
2015-01-01
A new health surveillance protocol for work-related upper-extremity musculoskeletal disorders has been validated by comparing the results with a reference protocol. The studied protocol, Health Surveillance in Adverse Ergonomics Conditions (HECO), is a new version of the reference protocol modified for application in the Occupational Health Service (OHS). The HECO protocol contains both a screening part and a diagnosing part. Sixty-three employees were examined. The screening in HECO did not miss any diagnosis found when using the reference protocol, but in comparison to the reference protocol considerable time savings could be achieved. Fair to good agreement between the protocols was obtained for one or more diagnoses in neck/shoulders (86%, k = 0.62) and elbow/hands (84%, k = 0.49). Therefore, the results obtained using the HECO protocol can be compared with a reference material collected with the reference protocol, and thus provide information of the magnitude of disorders in an examined work group. Practitioner Summary: The HECO protocol is a relatively simple physical examination protocol for identification of musculoskeletal disorders in the neck and upper extremities. The protocol is a reliable and cost-effective tool for the OHS to use for occupational health surveillance in order to detect workplaces at high risk for developing musculoskeletal disorders.
Tobe, Ruoyan Gai; Mori, Rintaro; Huang, Lihui; Xu, Lingzhong; Han, Demin; Shibuya, Kenji
2013-01-01
Background In 2009, the Chinese Ministry of Health recommended scale-up of routine neonatal hearing screening - previously performed primarily only in select urban hospitals - throughout the entire country. Methods A decision analytical model for a simulated population of all live births in China was developed to compare the costs and health effects of five mutually exclusive interventions: 1) universal screening using Otoacoustic Emission (OAE) and Automated Auditory Brainstem Response (AABR); 2) universal OAE; 3) targeted OAE and AABR; 4) targeted OAE; and 5) no screening. Disability-Adjusted Life Years (DALYs) were calculated for health effects. Results and Discussion Based on the cost-effectiveness and potential health outcomes, the optimal path for scale-up would be to start with targeted OAE and then expand to universal OAE and universal OAE plus AABR. Accessibility of screening, diagnosis, and intervention services significantly affect decision of the options. Conclusion In conclusion, to achieve cost-effectiveness and best health outcomes of the NHS program, the accessibility of screening, diagnosis, and intervention services should be expanded to reach a larger population. The results are thus expected to be of particular benefit in terms of the ‘rolling out’ of the national plan. PMID:23341887
Pilot study on the use of data mining to identify cochlear implant candidates.
Grisel, Jedidiah J; Schafer, Erin; Lam, Anne; Griffin, Terry
2018-05-01
The goal of this pilot study was to determine the clinical utility of data-mining software that screens for cochlear implant (CI) candidacy. The Auditory Implant Initiative developed a software module that screens for CI candidates via integration with a software system (Noah 4) that serves as a depository for hearing test data. To identify candidates, patient audiograms from one practice were exported into the screening module. Candidates were tracked to determine if any eventually underwent implantation. After loading 4836 audiograms from the Noah 4 system, the screening module identified 558 potential CI candidates. After reviewing the data for the potential candidates, 117 were targeted and invited to an educational event. Following the event, a total of six candidates were evaluated, and two were implanted. This objective approach to identifying candidates has the potential to address the gross underutilization of CIs by removing any bias or lack of knowledge regarding the management of severe to profound sensorineural hearing loss with CIs. The screening module was an effective tool for identifying potential CI candidates at one ENT practice. On a larger scale, the screening module has the potential to impact thousands of CI candidates worldwide.
Yoshinaga-Itano, Christine; Wiggin, Mallene
2016-11-01
Hearing is essential for the development of speech, spoken language, and listening skills. Children previously went undiagnosed with hearing loss until they were 2.5 or 3 years of age. The auditory deprivation during this critical period of development significantly impacted long-term listening and spoken language outcomes. Due to the advent of universal newborn hearing screening, the average age of diagnosis has dropped to the first few months of life, which sets the stage for outcomes that include children with speech, spoken language, and auditory skill testing in the normal range. However, our work is not finished. The future holds even greater possibilities for children with hearing loss. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
The Role of Audiologic Evaluation in Progressive Audiologic Tinnitus Management
Henry, James A.; Zaugg, Tara L.; Myers, Paula J.; Schechter, Martin A.
2008-01-01
Progressive Audiologic Tinnitus Management (PATM) is based on the premise that tinnitus is managed most efficiently using a hierarchy of clinical services that address different levels of need. PATM includes five levels of management: (a) triage; (b) audiologic evaluation; (c) group education; (d) tinnitus evaluation; and (e) individualized management. This article provides an overview of PATM and focuses on the procedures that make up the Level 2 Audiologic Evaluation. The evaluation is conducted to assess the potential need for medical, audiologic (hearing loss, tinnitus, hyperacusis), and/or mental health services. The Tinnitus Handicap Inventory, Hearing Handicap Inventory, and Tinnitus and Hearing Survey are used to differentiate effects of tinnitus and hearing loss. If indicated, patients are interviewed with the Tinnitus-Impact Screening Interview. Patients requiring amplification receive hearing aids. Often, management of hearing loss at Level 2 addresses any problems that were attributed to the tinnitus, which obviates further tinnitus-specific intervention. PMID:18628281
Wilson, Richard H; Noe, Colleen M; Cruickshanks, Karen J; Wiley, Terry L; Nondahl, David M
2010-01-01
The Epidemiology of Hearing Loss Study (EHLS) conducted in Beaver Dam, Wisconsin, was a population-based study that focused on the prevalence of hearing loss among 3,753 participants between 1993 and 1995. This article reports the results of several auditory measures from 999 veteran and 590 nonveteran males 48 to 92 years of age included in the EHLS. The auditory measures included pure tone thresholds, tympanometry and acoustic reflexes, word recognition in quiet and in competing message, and the Hearing Handicap Inventory for the Elderly-Screening (HHIE-S) version. Hearing loss in the auditory domains of pure tone thresholds, word recognition in quiet, and word recognition in competing message increased with age but were not significantly different for the veterans and nonveterans. No significant differences were found between participant groups on the HHIE-S; however, regarding hearing aid usage, mixed differences were found.
Mental health and self-image among deaf and hard of hearing children.
Mejstad, Lena; Heiling, Kerstin; Svedin, Carl Göran
2009-01-01
Mental health and self-image among deaf and hard of hearing children (ages 11-18 years) in southern Sweden was investigated. The children (N = 111) attended special schools for the deaf (n = 28), special schools for the hard of hearing (n = 23), and regular schools where hard of hearing children were mainstreamed (n = 60). The Strengths and Difficulties Questionnaire (Goodman, 1997) was used to screen mental health and the "I Think I Am" questionnaire Ouvinen-Birgerstam (1982, 1984) to measure self-esteem. The study shows that hard of hearing children seem to do as well, as a group, as other children in Swedish society. Mean SDQ and ITIA scores indicated that the mainstreamed students and the students in special schools for the hard of hearing had higher levels of rated mental health and self-image than the students in schools for the deaf.
An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.
Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa
2016-04-01
To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS(®) assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1%) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.
Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa
2016-11-01
To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS ® assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1 %) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Palomaki, Glenn E; Lee, Jo Ellen S; Canick, Jacob A; McDowell, Geraldine A; Donnenfeld, Alan E
2009-09-01
This statement is intended to augment the current general ACMG Standards and Guidelines for Clinical Genetics Laboratories and to address guidelines specific to first-trimester screening for Down syndrome. The aim is to provide the laboratory the necessary information to ensure accurate and reliable Down syndrome screening results given a screening protocol (e.g., combined first trimester and integrated testing). Information about various test combinations and their expected performance are provided, but other issues such as availability of reagents, patient interest in early test results, access to open neural tube defect screening, and availability of chorionic villus sampling are all contextual factors in deciding which screening protocol(s) will be selected by individual health care providers. Individual laboratories are responsible for meeting the quality assurance standards described by the Clinical Laboratory Improvement Act, the College of American Pathologists, and other regulatory agencies, with respect to appropriate sample documentation, assay validation, general proficiency, and quality control measures. These guidelines address first-trimester screening that includes ultrasound measurement and interpretation of nuchal translucency thickness and protocols that combine markers from both the first and second trimesters. Laboratories can use their professional judgment to make modification or additions.
Castiglione, Alessandro; Benatti, Alice; Velardita, Carmelita; Favaro, Diego; Padoan, Elisa; Severi, Daniele; Pagliaro, Michela; Bovo, Roberto; Vallesi, Antonino; Gabelli, Carlo; Martini, Alessandro
2016-01-01
A growing interest in cognitive effects associated with speech and hearing processes is spreading throughout the scientific community essentially guided by evidence that central and peripheral hearing loss is associated with cognitive decline. For the present research, 125 participants older than 65 years of age (105 with hearing impairment and 20 with normal hearing) were enrolled, divided into 6 groups according to their degree of hearing loss and assessed to determine the effects of the treatment applied. Patients in our research program routinely undergo an extensive audiological and cognitive evaluation protocol providing results from the Digit Span test, Stroop color-word test, Montreal Cognitive Assessment and Geriatric Depression Scale, before and after rehabilitation. Data analysis was performed for a cross-sectional and longitudinal study of the outcomes for the different treatment groups. Each group demonstrated improvement after auditory rehabilitation or training on short- and long-term memory tasks, level of depression and cognitive status scores. Auditory rehabilitation by cochlear implants or hearing aids is effective also among older adults (median age of 74 years) with different degrees of hearing loss, and enables positive improvements in terms of social isolation, depression and cognitive performance. © 2016 The Author(s) Published by S. Karger AG, Basel.
Palmer, Christina G.S.; Martinez, Ariadna; Fox, Michelle; Zhou, Jin; Shapiro, Nina; Sininger, Yvonne; Grody, Wayne W.; Schimmenti, Lisa A.
2010-01-01
There are limited data on the impact of incorporating genetic counseling and testing into the newborn hearing screening process. We report on results from a prospective, longitudinal study to determine the impact of genetic counseling and GJB2/GJB6 genetic testing on parental knowledge, attitudes, and beliefs about genetic testing. One hundred thirty culturally hearing parents of 93 deaf or hard-of-hearing children ages 0 – 3 years primarily identified through newborn hearing screening received pre- and post-test genetic counseling for GJB2 and GJB6. Parents completed questionnaires following pre-test counseling, and 1- and 6-months post-test result disclosure. Results indicate that following pre-test counseling all parents perceived benefits to genetic testing. While parents who received positive results continued to perceive benefits from testing, perceived benefit declined among parents who received inconclusive or negative results. Parents did not perceive genetic testing as harmful following pre-test counseling or receipt of test results. Parents who received positive test results performed better in understanding recurrence and causation of their child’s deafness and indicated greater interest in prenatal genetic testing than those who received inconclusive or negative test results. Parents felt that pediatricians and audiologists should inform parents of genetic testing availability; however, there was no consensus on timing of this discussion. Thus culturally hearing parents do not perceive genetic testing of their deaf or hard-of-hearing infants/toddlers as harmful; they feel that primary care providers should discuss genetic testing with them; and positive genetic test results with genetic counseling give rise to better understanding and perceived benefit than negative or inconclusive results. PMID:19449415
Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva
2015-01-01
Introduction The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. Objective This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. Data Synthesis This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: “Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?” The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. Conclusion The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace. PMID:27413413
Palmer, Christina G S; Martinez, Ariadna; Fox, Michelle; Zhou, Jin; Shapiro, Nina; Sininger, Yvonne; Grody, Wayne W; Schimmenti, Lisa A
2009-06-01
There are limited data on the impact of incorporating genetic counseling and testing into the newborn hearing screening process. We report on results from a prospective, longitudinal study to determine the impact of genetic counseling and GJB2/GJB6 genetic testing on parental knowledge, attitudes, and beliefs about genetic testing. One hundred thirty culturally hearing parents of 93 deaf or hard-of-hearing children ages 0-3 years primarily identified through newborn hearing screening received pre- and post-test genetic counseling for GJB2 and GJB6. Parents completed questionnaires following pre-test counseling, and 1- and 6-month post-test result disclosure. Results indicate that following pre-test counseling all parents perceived benefits to genetic testing. While parents who received positive results continued to perceive benefits from testing, perceived benefit declined among parents who received inconclusive or negative results. Parents did not perceive genetic testing as harmful following pre-test counseling or receipt of test results. Parents who received positive test results performed better in understanding recurrence and causation of their child's deafness and indicated greater interest in prenatal genetic testing than those who received inconclusive or negative test results. Parents felt that pediatricians and audiologists should inform parents of genetic testing availability; however, there was no consensus on timing of this discussion. Thus culturally hearing parents do not perceive genetic testing of their deaf or hard-of-hearing infants/toddlers as harmful; they feel that primary care providers should discuss genetic testing with them; and positive genetic test results with genetic counseling give rise to better understanding and perceived benefit than negative or inconclusive results. (c) 2009 Wiley-Liss, Inc.
Zdrazil, B.; Neefs, J.-M.; Van Vlijmen, H.; Herhaus, C.; Caracoti, A.; Brea, J.; Roibás, B.; Loza, M. I.; Queralt-Rosinach, N.; Furlong, L. I.; Gaulton, A.; Bartek, L.; Senger, S.; Chichester, C.; Engkvist, O.; Evelo, C. T.; Franklin, N. I.; Marren, D.; Ecker, G. F.
2016-01-01
Phenotypic screening is in a renaissance phase and is expected by many academic and industry leaders to accelerate the discovery of new drugs for new biology. Given that phenotypic screening is per definition target agnostic, the emphasis of in silico and in vitro follow-up work is on the exploration of possible molecular mechanisms and efficacy targets underlying the biological processes interrogated by the phenotypic screening experiments. Herein, we present six exemplar computational protocols for the interpretation of cellular phenotypic screens based on the integration of compound, target, pathway, and disease data established by the IMI Open PHACTS project. The protocols annotate phenotypic hit lists and allow follow-up experiments and mechanistic conclusions. The annotations included are from ChEMBL, ChEBI, GO, WikiPathways and DisGeNET. Also provided are protocols which select from the IUPHAR/BPS Guide to PHARMACOLOGY interaction file selective compounds to probe potential targets and a correlation robot which systematically aims to identify an overlap of active compounds in both the phenotypic as well as any kinase assay. The protocols are applied to a phenotypic pre-lamin A/C splicing assay selected from the ChEMBL database to illustrate the process. The computational protocols make use of the Open PHACTS API and data and are built within the Pipeline Pilot and KNIME workflow tools. PMID:27774140
The effects and outcomes of electrolyte disturbances and asphyxia on newborns hearing
Liang, Chun; Hong, Qi; Jiang, Tao-Tao; Gao, Yan; Yao, Xiao-Fang; Luo, Xiao-Xing; Zhuo, Xiu-Hui; Shinn, Jennifer B.; Jones, Raleigh O.; Zhao, Hong-Bo; Lu, Guang-Jin
2013-01-01
Objective To determine the effect of electrolyte disturbances (ED) and asphyxia on infant hearing and hearing outcomes. Study Design We conducted newborn hearing screening with transient evoked otoacoustic emission (TEOAE) test on a large scale (>5,000 infants). The effects of ED and asphyxia on infant hearing and hearing outcomes were evaluated. Result The pass rate of TEOAE test was significantly reduced in preterm infants with ED (83.1%, multiple logistic regression analysis: P<0.01) but not in full-term infants with ED (93.6%, P=0.41). However, there was no significant reduction in the pass rate in infants with asphyxia (P=0.85). We further found that hypocalcaemia significantly reduced the pass rate of TEOAE test (86.8%, P<0.01). In the follow-up recheck at 3 months of age, the pass rate remained low (44.4%, P<0.01). Conclusion ED is a high-risk factor for preterm infant hearing. Hypocalcaemia can produce more significant impairment with a low recovery rate. PMID:23648318
Sudden onset unilateral sensorineural hearing loss after rabies vaccination.
Okhovat, Saleh; Fox, Richard; Magill, Jennifer; Narula, Antony
2015-12-15
A 33-year-old man developed profound sudden onset right-sided hearing loss with tinnitus and vertigo, within 24 h of pretravel rabies vaccination. There was no history of upper respiratory tract infection, systemic illness, ototoxic medication or trauma, and normal otoscopic examination. Pure tone audiograms (PTA) demonstrated right-sided sensorineural hearing loss (thresholds 90-100 dB) and normal left-sided hearing. MRI internal acoustic meatus, viral serology (hepatitis B, C, HIV and cytomegalovirus) and syphilis screen were normal. Positive Epstein-Barr virus IgG, viral capsid IgG and anticochlear antibodies (anti-HSP-70) were noted. Initial treatment involved a course of high-dose oral prednisolone and acyclovir. Repeat PTAs after 12 days of treatment showed a small improvement in hearing thresholds. Salvage intratympanic steroid injections were attempted but failed to improve hearing further. Sudden onset sensorineural hearing loss (SSNHL) is an uncommon but frightening experience for patients. This is the first report of SSNHL following rabies immunisation in an adult. 2015 BMJ Publishing Group Ltd.
Portnuff, Cory D F; Kleindienst, Samantha; Bogle, Jamie M
2017-09-01
Vestibular-evoked myogenic potentials (VEMPs) are commonly used clinical assessments for patients with complaints of dizziness. However, relatively high air-conducted stimuli are required to elicit the VEMP, and ultimately may compromise safe noise exposure limits. Recently, research has reported the potential for noise-induced hearing loss (NIHL) from VEMP stimulus exposure through studies of reduced otoacoustic emission levels after VEMP testing, as well as a recent case study showing permanent sensorineural hearing loss associated with VEMP exposure. The purpose of this report is to review the potential for hazardous noise exposure from VEMP stimuli and to suggest clinical parameters for safe VEMP testing. Literature review with presentation of clinical guidelines and a clinical tool for estimating noise exposure. The literature surrounding VEMP stimulus-induced hearing loss is reviewed, including several cases of overexposure. The article then presents a clinical calculation tool for the estimation of a patient's safe noise exposure from VEMP stimuli, considering stimulus parameters, and includes a discussion of how varying stimulus parameters affect a patient's noise exposure. Finally, recommendations are provided for recognizing and managing specific patient populations who may be at higher risk for NIHL from VEMP stimulus exposure. A sample protocol is provided that allows for safe noise exposure. VEMP stimuli have the potential to cause NIHL due to high sound exposure levels. However, with proper safety protocols in place, clinicians may reduce or eliminate this risk to their patients. Use of the tools provided, including the noise exposure calculation tool and sample protocols, may help clinicians to understand and ensure safe use of VEMP stimuli. American Academy of Audiology
The U.S EPA Endocrine Disruptor Screening Program Tier 1 male pubertal protocol was designed to detect reproductive development and thyroid function. One purpose of this in vivo protocol is to detect thyrotoxicants via a number of different mechanisms of action. Here we evaluate ...
DE-71, a commercial mixture, was used to test the sensitivity of the female and male pubertal protocol to detect thyroid active chemicals. These protocols are being evaluated for the U.S. EPA's Endocrine Disruptor Screening Program as part of a Tier I Screening Battery. To exa...
ERIC Educational Resources Information Center
Strong, Carol J.; And Others
SKI*HI is a program designed to identify children with hearing impairments as early as possible and to provide them and their families with complete home programming that will facilitate development. The delivery model includes identification/screening services, home visit services, support services, and program management. A parent advisor makes…
Visual Attention in Deaf and Normal Hearing Adults: Effects of Stimulus Compatibility
ERIC Educational Resources Information Center
Sladen, Douglas P.; Tharpe, Anne Marie; Ashmead, Daniel H.; Grantham, D. Wesley; Chun, Marvin M.
2005-01-01
Visual perceptual skills of deaf and normal hearing adults were measured using the Eriksen flanker task. Participants were seated in front of a computer screen while a series of target letters flanked by similar or dissimilar letters was flashed in front of them. Participants were instructed to press one button when they saw an "H," and another…
ERIC Educational Resources Information Center
Li, Degao; Gao, Kejuan; Wu, Xueyun; Xong, Ying; Chen, Xiaojun; He, Weiwei; Li, Ling; Huang, Jingjia
2015-01-01
Two experiments investigated Chinese deaf and hard of hearing (DHH) adolescents' recognition of category names in an innovative task of semantic categorization. In each trial, the category-name target appeared briefly at the screen center followed by two words or two pictures for two basic-level exemplars of high or middle typicality, which…
ERIC Educational Resources Information Center
Snoddon, Kristin
2015-01-01
No formal Canadian curriculum presently exists for teaching American Sign Language (ASL) as a second language to parents of deaf and hard of hearing children. However, this group of ASL learners is in need of more comprehensive, research-based support, given the rapid expansion in Canada of universal neonatal hearing screening and the…
Newborn screening for cystic fibrosis in Wisconsin: comparison of biochemical and molecular methods.
Gregg, R G; Simantel, A; Farrell, P M; Koscik, R; Kosorok, M R; Laxova, A; Laessig, R; Hoffman, G; Hassemer, D; Mischler, E H; Splaingard, M
1997-06-01
To evaluate neonatal screening for cystic fibrosis (CF), including study of the screening procedures and characteristics of false-positive infants, over the past 10 years in Wisconsin. An important objective evolving from the original design has been to compare use of a single-tier immunoreactive trypsinogen (IRT) screening method with that of a two-tier method using IRT and analyses of samples for the most common cystic fibrosis transmembrane regulator (CFTR) (DeltaF508) mutation. We also examined the benefit of including up to 10 additional CFTR mutations in the screening protocol. From 1985 to 1994, using either the IRT or IRT/DNA protocol, 220 862 and 104 308 neonates, respectively, were screened for CF. For the IRT protocol, neonates with an IRT >/=180 ng/mL were considered positive, and the standard sweat chloride test was administered to determine CF status. For the IRT/DNA protocol, samples from the original dried-blood specimen on the Guthrie card of neonates with an IRT >/=110 ng/mL were tested for the presence of the DeltaF508 CFTR allele, and if the DNA test revealed one or two DeltaF508 alleles, a sweat test was obtained. Both screening procedures had very high specificity. The sensitivity tended to be higher with the IRT/DNA protocol, but the differences were not statistically significant. The positive predictive value of the IRT/DNA screening protocol was 15.2% compared with 6.4% if the same samples had been screened by the IRT method. Assessment of the false-positive IRT/DNA population revealed that the two-tier method eliminates the disproportionate number of infants with low Apgar scores and also the high prevalence of African-Americans identified previously in our study of newborns with high IRT levels. We found that 55% of DNA-positive CF infants were homozygous for DeltaF508 and 40% had one DeltaF508 allele. Adding analyses for 10 more CFTR mutations has only a small effect on the sensitivity but is likely to add significantly to the cost of screening. Advantages of the IRT/DNA protocol over IRT analysis include improved positive predictive value, reduction of false-positive infants, and more rapid diagnosis with elimination of recall specimens.
Therrell, Bradford L
2003-01-01
At birth, patient demographic and health information begin to accumulate in varied databases. There are often multiple sources of the same or similar data. New public health programs are often created without considering data linkages. Recently, newborn hearing screening (NHS) programs and immunization programs have virtually ignored the existence of newborn dried blood spot (DBS) newborn screening databases containing similar demographic data, creating data duplication in their 'new' systems. Some progressive public health departments are developing data warehouses of basic, recurrent patient information, and linking these databases to other health program databases where programs and services can benefit from such linkages. Demographic data warehousing saves time (and money) by eliminating duplicative data entry and reducing the chances of data errors. While newborn screening data are usually the first data available, they should not be the only data source considered for early data linkage or for populating a data warehouse. Birth certificate information should also be considered along with other data sources for infants that may not have received newborn screening or who may have been born outside of the jurisdiction and not have birth certificate information locally available. This newborn screening serial number provides a convenient identification number for use in the DBS program and for linking with other systems. As a minimum, data linkages should exist between newborn dried blood spot screening, newborn hearing screening, immunizations, birth certificates and birth defect registries.
Smith, Eric E; Kent, David M; Bulsara, Ketan R; Leung, Lester Y; Lichtman, Judith H; Reeves, Mathew J; Towfighi, Amytis; Whiteley, William N; Zahuranec, Darin B
2018-03-01
Dysphagia screening protocols have been recommended to identify patients at risk for aspiration. The American Heart Association convened an evidence review committee to systematically review evidence for the effectiveness of dysphagia screening protocols to reduce the risk of pneumonia, death, or dependency after stroke. The Medline, Embase, and Cochrane databases were searched on November 1, 2016, to identify randomized controlled trials (RCTs) comparing dysphagia screening protocols or quality interventions with increased dysphagia screening rates and reporting outcomes of pneumonia, death, or dependency. Three RCTs were identified. One RCT found that a combined nursing quality improvement intervention targeting fever and glucose management and dysphagia screening reduced death and dependency but without reducing the pneumonia rate. Another RCT failed to find evidence that pneumonia rates were reduced by adding the cough reflex to routine dysphagia screening. A smaller RCT randomly assigned 2 hospital wards to a stroke care pathway including dysphagia screening or regular care and found that patients on the stroke care pathway were less likely to require intubation and mechanical ventilation; however, the study was small and at risk for bias. There were insufficient RCT data to determine the effect of dysphagia screening protocols on reducing the rates of pneumonia, death, or dependency after stroke. Additional trials are needed to compare the validity, feasibility, and clinical effectiveness of different screening methods for dysphagia. © 2018 American Heart Association, Inc.
Validation of a school-based amblyopia screening protocol in a kindergarten population.
Casas-Llera, Pilar; Ortega, Paula; Rubio, Inmaculada; Santos, Verónica; Prieto, María J; Alio, Jorge L
2016-08-04
To validate a school-based amblyopia screening program model by comparing its outcomes to those of a state-of-the-art conventional ophthalmic clinic examination in a kindergarten population of children between the ages of 4 and 5 years. An amblyopia screening protocol, which consisted of visual acuity measurement using Lea charts, ocular alignment test, ocular motility assessment, and stereoacuity with TNO random-dot test, was performed at school in a pediatric 4- to 5-year-old population by qualified healthcare professionals. The outcomes were validated in a selected group by a conventional ophthalmologic examination performed in a fully equipped ophthalmologic center. The ophthalmologic evaluation was used to confirm whether or not children were correctly classified by the screening protocol. The sensitivity and specificity of the test model to detect amblyopia were established. A total of 18,587 4- to 5-year-old children were subjected to the amblyopia screening program during the 2010-2011 school year. A population of 100 children were selected for the ophthalmologic validation screening. A sensitivity of 89.3%, specificity of 93.1%, positive predictive value of 83.3%, negative predictive value of 95.7%, positive likelihood ratio of 12.86, and negative likelihood ratio of 0.12 was obtained for the amblyopia screening validation model. The amblyopia screening protocol model tested in this investigation shows high sensitivity and specificity in detecting high-risk cases of amblyopia compared to the standard ophthalmologic examination. This screening program may be highly relevant for amblyopia screening at schools.
Evaluation of auditory functions for Royal Canadian Mounted Police officers.
Vaillancourt, Véronique; Laroche, Chantal; Giguère, Christian; Beaulieu, Marc-André; Legault, Jean-Pierre
2011-06-01
Auditory fitness for duty (AFFD) testing is an important element in an assessment of workers' ability to perform job tasks safely and effectively. Functional hearing is particularly critical to job performance in law enforcement. Most often, assessment is based on pure-tone detection thresholds; however, its validity can be questioned and challenged in court. In an attempt to move beyond the pure-tone audiogram, some organizations like the Royal Canadian Mounted Police (RCMP) are incorporating additional testing to supplement audiometric data in their AFFD protocols, such as measurements of speech recognition in quiet and/or in noise, and sound localization. This article reports on the assessment of RCMP officers wearing hearing aids in speech recognition and sound localization tasks. The purpose was to quantify individual performance in different domains of hearing identified as necessary components of fitness for duty, and to document the type of hearing aids prescribed in the field and their benefit for functional hearing. The data are to help RCMP in making more informed decisions regarding AFFD in officers wearing hearing aids. The proposed new AFFD protocol included unaided and aided measures of speech recognition in quiet and in noise using the Hearing in Noise Test (HINT) and sound localization in the left/right (L/R) and front/back (F/B) horizontal planes. Sixty-four officers were identified and selected by the RCMP to take part in this study on the basis of hearing thresholds exceeding current audiometrically based criteria. This article reports the results of 57 officers wearing hearing aids. Based on individual results, 49% of officers were reclassified from nonoperational status to operational with limitations on fine hearing duties, given their unaided and/or aided performance. Group data revealed that hearing aids (1) improved speech recognition thresholds on the HINT, the effects being most prominent in Quiet and in conditions of spatial separation between target and noise (Noise Right and Noise Left) and least considerable in Noise Front; (2) neither significantly improved nor impeded L/R localization; and (3) substantially increased F/B errors in localization in a number of cases. Additional analyses also pointed to the poor ability of threshold data to predict functional abilities for speech in noise (r² = 0.26 to 0.33) and sound localization (r² = 0.03 to 0.28). Only speech in quiet (r² = 0.68 to 0.85) is predicted adequately from threshold data. Combined with previous findings, results indicate that the use of hearing aids can considerably affect F/B localization abilities in a number of individuals. Moreover, speech understanding in noise and sound localization abilities were poorly predicted from pure-tone thresholds, demonstrating the need to specifically test these abilities, both unaided and aided, when assessing AFFD. Finally, further work is needed to develop empirically based hearing criteria for the RCMP and identify best practices in hearing aid fittings for optimal functional hearing abilities. American Academy of Audiology.
Lewis, Dawna E; Smith, Nicholas A; Spalding, Jody L; Valente, Daniel L
Visual information from talkers facilitates speech intelligibility for listeners when audibility is challenged by environmental noise and hearing loss. Less is known about how listeners actively process and attend to visual information from different talkers in complex multi-talker environments. This study tracked looking behavior in children with normal hearing (NH), mild bilateral hearing loss (MBHL), and unilateral hearing loss (UHL) in a complex multi-talker environment to examine the extent to which children look at talkers and whether looking patterns relate to performance on a speech-understanding task. It was hypothesized that performance would decrease as perceptual complexity increased and that children with hearing loss would perform more poorly than their peers with NH. Children with MBHL or UHL were expected to demonstrate greater attention to individual talkers during multi-talker exchanges, indicating that they were more likely to attempt to use visual information from talkers to assist in speech understanding in adverse acoustics. It also was of interest to examine whether MBHL, versus UHL, would differentially affect performance and looking behavior. Eighteen children with NH, eight children with MBHL, and 10 children with UHL participated (8-12 years). They followed audiovisual instructions for placing objects on a mat under three conditions: a single talker providing instructions via a video monitor, four possible talkers alternately providing instructions on separate monitors in front of the listener, and the same four talkers providing both target and nontarget information. Multi-talker background noise was presented at a 5 dB signal-to-noise ratio during testing. An eye tracker monitored looking behavior while children performed the experimental task. Behavioral task performance was higher for children with NH than for either group of children with hearing loss. There were no differences in performance between children with UHL and children with MBHL. Eye-tracker analysis revealed that children with NH looked more at the screens overall than did children with MBHL or UHL, though individual differences were greater in the groups with hearing loss. Listeners in all groups spent a small proportion of time looking at relevant screens as talkers spoke. Although looking was distributed across all screens, there was a bias toward the right side of the display. There was no relationship between overall looking behavior and performance on the task. The present study examined the processing of audiovisual speech in the context of a naturalistic task. Results demonstrated that children distributed their looking to a variety of sources during the task, but that children with NH were more likely to look at screens than were those with MBHL/UHL. However, all groups looked at the relevant talkers as they were speaking only a small proportion of the time. Despite variability in looking behavior, listeners were able to follow the audiovisual instructions and children with NH demonstrated better performance than children with MBHL/UHL. These results suggest that performance on some challenging multi-talker audiovisual tasks is not dependent on visual fixation to relevant talkers for children with NH or with MBHL/UHL.
Ensuring financial access to hearing AIDS for infants and young children.
Limb, Stephanie J; McManus, Margaret A; Fox, Harriette B; White, Karl R; Forsman, Irene
2010-08-01
Many young children with permanent hearing loss do not receive hearing aids and related professional services, in part because of public and private financing limitations. In 2006 the Children's Audiology Financing Workgroup was convened by the National Center for Hearing Assessment and Management to evaluate and make recommendations about public and private financing of hearing aids and related professional services for 0- to 3-year-old children. The workgroup recommended 4 possible strategies for ensuring that all infants and young children with hearing loss have access to appropriate hearing aids and professional services: (1) clarify that the definition of assistive technology, which is a required service under Part C of the Individuals With Disabilities Education Act (IDEA), includes not only analog hearing aids but also digital hearing aids with appropriate features as needed by young children with hearing loss; (2) clarify for both state Medicaid and Children's Health Insurance Programs that digital hearing aids are almost always the medically necessary type of hearing aid required for infants and young children and should be covered under the Early and Periodic Screening, Diagnosis, and Treatment (EPSDT) program; (3) encourage the passage of private health insurance legislative mandates to require coverage of appropriate digital hearing aids and related professional services for infants and young children; and (4) establish hearing-aid loaner programs in every state. The costs of providing hearing aids to all 0- to 3-year old children in the United States are estimated here.
Kong, Tae Hoon; Park, Yoon Ah; Bong, Jeong Pyo; Park, Sang Yoo
2017-07-01
Spatial hearing refers to the ability to understand speech and identify sounds in various environments. We assessed the validity of the Korean version of the Spatial Hearing Questionnaire (K-SHQ). We performed forward translation of the original English SHQ to Korean and backward translation from the Korean to English. Forty-eight patients who were able to read and understand Korean and received a score of 24 or higher on the Mini-Mental Status Examination were included in the study. Patients underwent pure tone audiometry (PTA) using a standard protocol and completed the K-SHQ. Internal consistency was evaluated using Cronbach's alpha, and factor analysis was performed to prove reliability. Construct validity was tested by comparing K-SHQ scores from patients with normal hearing to those with hearing impairment. Scores were compared between subjects with unilateral or bilateral hearing loss and between symmetrical and asymmetrical hearing impairment. Cronbach's alpha showed good internal consistency (0.982). Two factors were identified by factor analysis: There was a significant difference in K-SHQ scores for patients with normal hearing compared to those with hearing impairment. Patients with asymmetric hearing impairment had higher K-SHQ scores than those with symmetric hearing impairment. This is related to a lower threshold of PTA in the better ear of subjects. The hearing ability of the better ear is correlated with K-SHQ score. The K-SHQ is a reliable and valid tool with which to assess spatial hearing in patients who speak and read Korean. K-SHQ score reflects the severity and symmetry of hearing impairment. © Copyright: Yonsei University College of Medicine 2017
The effect of tinnitus retraining therapy on chronic tinnitus: A controlled trial
Berry, Jennifer L.; Brozoski, Thomas J.
2017-01-01
Objectives The goal of this study was to compare treatment outcomes for chronic bothersome tinnitus after Tinnitus Retraining Therapy (TRT) versus standard of care treatment (SC) and to determine the longevity of the effect over an 18‐month period. Study Design A randomized controlled trial comparing TRT to SC for chronic tinnitus. Methods Adults with subjective, stable, bothersome chronic tinnitus associated with hearing loss amenable to aural rehabilitation with hearing aids were recruited. The Tinnitus Handicap Inventory (THI) was the primary outcome measure and the Tinnitus Functional Index (TFI) the secondary outcome measure of tinnitus severity and impact. Data were collected at screening, entry (0 months), and 6, 12, and 18 months after the beginning of treatment, using an integrated digitized suite of evaluation modules. TRT consisted of directive counseling and acoustic enrichment using combination hearing aids and sound generators; SC consisted of general aural rehabilitation counseling and hearing aids. Results Significant improvement in tinnitus impact occurred after both TRT and SC therapy, with a larger treatment effect obtained in the TRT group. Lasting therapeutic benefit was evident at 18 months in both groups. THI initial scores were unstable in 10% of enrolled participants, showing moderate bidirectional fluctuation between screening and baseline (0 month) assessment. Conclusion Adults with moderate to severe tinnitus and hearing loss amenable to amplification, benefit from either TRT or SC treatment when combined with hearing aid use. TRT benefit may exceed that of SC. The global improvement in tinnitus severity that accrued over an 18‐month period appeared to be robust and clinically significant. Level of Evidence I PMID:28894836
Miyagawa, Maiko; Nishio, Shin-Ya; Usami, Shin-Ichi
2016-01-01
Objective: Cochlear implantation is the most important treatment currently available for profound sensorineural hearing loss. The aim of this study was to investigate the etiology of hearing loss in patients with cochlear implantation, and to compare outcomes. Methods: Japanese hearing loss patients who received cochlear implants (CIs) or electric acoustic stimulation (EAS) in Shinshu University hospital (n = 173, prelingual onset: 92, postlingual onset: 81) participated in this study. Invader assay followed by the targeted exon-sequencing of 63 deafness genes using Massively parallel DNA sequencing (MPS) was applied. For prelingual patients, additional imaging examination, cCMV screening, and pediatric examination were performed for precise diagnosis. Results: Genetic screening successfully identified the causative mutation in 60% of patients with prelingual onset hearing loss and in 36% of those with postlingual hearing loss. Differences in the kinds of genes identified were observed between the two groups. Although there were marked variations in the outcome of cochlear implantation, patients with specific deafness gene mutations showed relatively good results. Conclusion: The present study showed genetic etiology is a major cause of hearing loss in CI/EAS patients. Patients possessing mutations in a number of deafness genes known to be expressed within inner ear have achieved satisfactory auditory performance, suggesting that the identification of the genetic background facilitates the prediction of post-CI performance. MPS is a powerful tool for the identification of causative deafness genes in patients receiving cochlear implantation. Therefore, determination of the involved region inside/outside of the cochlea by identification of the responsible gene is essential. PMID:26756145
Pomerleau, Geneviève; Hurteau, Anne-Marie; Parent, Line; Doucet, Katrine; Corbin-Berrigan, Laurie-Ann; Gagnon, Isabelle
2012-01-01
The purpose of this study was to review the feasibility and usefulness of instituting a clinical protocol of scheduled assessments for children after a moderate or severe traumatic brain injury (TBI) sustained before the age of 2 years and showing no immediate deficits at hospital discharge, as well as to explore the early developmental trajectories of these children. Exploratory analytical cohort study. Pediatric Trauma Center Out-patient services. 31 children were followed within the clinical protocol of scheduled assessments. The protocol included an immediate post-injury clinical assessment of infants who sustained a TBI and follow-up assessments at the ages of 9 months, 18 months (if injured prior to that age), 30 months, and 42 months. Domains assessed at each scheduled visit included hearing, speech and language, motor performance, personal social abilities, and adaptive behaviors. Clinicians reported few difficulties with scheduling or administering the assessments, maintaining a 67% participation rate at the end of the follow-up period, thus demonstrating the feasibility of the protocol in this population. Scores on the majority of formal tests showed high variability and 15-20% of children presented with clinically significant motor and/or language delays. By 42 months of age, difficulties with adaptive behavior and personal social abilities were identified in our sample of children when compared to published norms. Qualitative clinical findings from professionals identified between 25-50% of children with potential attentional difficulties throughout the follow-up period. Findings from this study demonstrate the feasibility of implementing a clinical protocol of assessment for infants and toddlers who sustain a TBI before the age of 2 years and present with no impairments at the time of discharge from hospital. Developmental problems in this population appear to be easier to identify later in the toddler years as opposed to immediately following the TBI, emphasizing the importance of providing screening for developmental issues in this population prior to school entry.
Jonker, Dirk; Gustafsson, Ewa; Rolander, Bo; Arvidsson, Inger; Nordander, Catarina
2015-01-01
A new health surveillance protocol for work-related upper-extremity musculoskeletal disorders has been validated by comparing the results with a reference protocol. The studied protocol, Health Surveillance in Adverse Ergonomics Conditions (HECO), is a new version of the reference protocol modified for application in the Occupational Health Service (OHS). The HECO protocol contains both a screening part and a diagnosing part. Sixty-three employees were examined. The screening in HECO did not miss any diagnosis found when using the reference protocol, but in comparison to the reference protocol considerable time savings could be achieved. Fair to good agreement between the protocols was obtained for one or more diagnoses in neck/shoulders (86%, k = 0.62) and elbow/hands (84%, k = 0.49). Therefore, the results obtained using the HECO protocol can be compared with a reference material collected with the reference protocol, and thus provide information of the magnitude of disorders in an examined work group. Practitioner Summary: The HECO protocol is a relatively simple physical examination protocol for identification of musculoskeletal disorders in the neck and upper extremities. The protocol is a reliable and cost-effective tool for the OHS to use for occupational health surveillance in order to detect workplaces at high risk for developing musculoskeletal disorders. PMID:25761380
Nair, Erika L; Sousa, Rhonda; Wannagot, Shannon
Guidelines established by the AAA currently recommend behavioral testing when fitting frequency modulated (FM) systems to individuals with cochlear implants (CIs). A protocol for completing electroacoustic measures has not yet been validated for personal FM systems or digital modulation (DM) systems coupled to CI sound processors. In response, some professionals have used or altered the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting FM systems to CI sound processors. More recently steps were outlined in a proposed protocol. The purpose of this research is to review and compare the electroacoustic test measures outlined in a 2013 article by Schafer and colleagues in the Journal of the American Academy of Audiology titled "A Proposed Electroacoustic Test Protocol for Personal FM Receivers Coupled to Cochlear Implant Sound Processors" to the AAA electroacoustic verification steps for fitting FM systems to hearing aids when fitting DM systems to CI users. Electroacoustic measures were conducted on 71 CI sound processors and Phonak Roger DM systems using a proposed protocol and an adapted AAA protocol. Phonak's recommended default receiver gain setting was used for each CI sound processor manufacturer and adjusted if necessary to achieve transparency. Electroacoustic measures were conducted on Cochlear and Advanced Bionics (AB) sound processors. In this study, 28 Cochlear Nucleus 5/CP810 sound processors, 26 Cochlear Nucleus 6/CP910 sound processors, and 17 AB Naida CI Q70 sound processors were coupled in various combinations to Phonak Roger DM dedicated receivers (25 Phonak Roger 14 receivers-Cochlear dedicated receiver-and 9 Phonak Roger 17 receivers-AB dedicated receiver) and 20 Phonak Roger Inspiro transmitters. Employing both the AAA and the Schafer et al protocols, electroacoustic measurements were conducted with the Audioscan Verifit in a clinical setting on 71 CI sound processors and Phonak Roger DM systems to determine transparency and verify FM advantage, comparing speech inputs (65 dB SPL) in an effort to achieve equal outputs. If transparency was not achieved at Phonak's recommended default receiver gain, adjustments were made to the receiver gain. The integrity of the signal was monitored with the appropriate manufacturer's monitor earphones. Using the AAA hearing aid protocol, 50 of the 71 CI sound processors achieved transparency, and 59 of the 71 CI sound processors achieved transparency when using the proposed protocol at Phonak's recommended default receiver gain. After the receiver gain was adjusted, 3 of 21 CI sound processors still did not meet transparency using the AAA protocol, and 2 of 12 CI sound processors still did not meet transparency using the Schafer et al proposed protocol. Both protocols were shown to be effective in taking reliable electroacoustic measurements and demonstrate transparency. Both protocols are felt to be clinically feasible and to address the needs of populations that are unable to reliably report regarding the integrity of their personal DM systems. American Academy of Audiology
Evidence of hearing loss in a “normally-hearing” college-student population
Le Prell, C. G.; Hensley, B.N.; Campbell, K. C. M.; Hall, J. W.; Guire, K.
2011-01-01
We report pure-tone hearing threshold findings in 56 college students. All subjects reported normal hearing during telephone interviews, yet not all subjects had normal sensitivity as defined by well-accepted criteria. At one or more test frequencies (0.25–8 kHz), 7% of ears had thresholds ≥25 dB HL and 12% had thresholds ≥20 dB HL. The proportion of ears with abnormal findings decreased when three-frequency pure-tone-averages were used. Low-frequency PTA hearing loss was detected in 2.7% of ears and high-frequency PTA hearing loss was detected in 7.1% of ears; however, there was little evidence for “notched” audiograms. There was a statistically reliable relationship in which personal music player use was correlated with decreased hearing status in male subjects. Routine screening and education regarding hearing loss risk factors are critical as college students do not always self-identify early changes in hearing. Large-scale systematic investigations of college students’ hearing status appear to be warranted; the current sample size was not adequate to precisely measure potential contributions of different sound sources to the elevated thresholds measured in some subjects. PMID:21288064
Amplitude changes in otoacoustic emissions after exposure to industrial noise.
Baradarnfar, Mohammad Hossein; Karamifar, Kayvan; Mehrparvar, Amir Houshang; Mollasadeghi, Abolfazl; Gharavi, Marjan; Karimi, Ghasem; Vahidy, Mohammad Reza; Baradarnfar, Amin; Mostaghaci, Mehrdad
2012-01-01
Noise-induced hearing loss (NIHL) is a frequent problem in industrial settings, especially where a high noise level is present. It is permanent, and irreversible, but preventable. Routine audiometry (an objective and time consuming) test is used for NIHL screening. Otoacoustic emissions (OAEs) are recently proposed as a more sensitive test for early diagnosis of NIHL. In this study, we aimed to compare the results of pure tone audiometry (PTA) with OAE in the diagnosis of NIHL. In a cross-sectional study on 120 workers (in three groups: Not exposed to noise, exposed to noise without NIHL and exposed to noise with NIHL), we compared the results of PTA and OAE. OAE can detect some changes in the function of hearing system in subjects exposed to noise, and these changes are apparently prior to hearing loss, which is diagnosed by PTA. OAE is a more sensitive method for the early diagnosis of cochlear damage than PTA, and can be performed in industrial settings for NIHL screening.
Comparison of muzzle suppression and ear-level hearing protection in firearm use.
Branch, Matthew Parker
2011-06-01
To compare noise reduction of commercially available ear-level hearing protection (muffs/inserts) to that of firearm muzzle suppressors. Experimental sound measurements under consistent environmental conditions. None. Muzzle suppressors for 2 pistol and 2 rifle calibers were tested using the Bruel & Kjaer 2209 sound meter and Bruel & Kjaer 4136 microphone calibrated with the Bruel & Kjaer Pistonphone using Military-Standard 1474D placement protocol. Five shots were recorded unsuppressed and 10 shots suppressed under consistent environmental conditions. Sound reduction was then compared with the real-world noise reduction rate of the best available ear-level protectors. All suppressors offered significantly greater noise reduction than ear-level protection, usually greater than 50% better. Noise reduction of all ear-level protectors is unable to reduce the impulse pressure below 140 dB for certain common firearms, an international standard for prevention of sensorineural hearing loss. Modern muzzle-level suppression is vastly superior to ear-level protection and the only available form of suppression capable of making certain sporting arms safe for hearing. The inadequacy of standard hearing protectors with certain common firearms is not recognized by most hearing professionals or their patients and should affect the way hearing professionals counsel patients and the public.
Making sense of listening: the IMAP test battery.
Barry, Johanna G; Ferguson, Melanie A; Moore, David R
2010-10-11
The ability to hear is only the first step towards making sense of the range of information contained in an auditory signal. Of equal importance are the abilities to extract and use the information encoded in the auditory signal. We refer to these as listening skills (or auditory processing AP). Deficits in these skills are associated with delayed language and literacy development, though the nature of the relevant deficits and their causal connection with these delays is hotly debated. When a child is referred to a health professional with normal hearing and unexplained difficulties in listening, or associated delays in language or literacy development, they should ideally be assessed with a combination of psychoacoustic (AP) tests, suitable for children and for use in a clinic, together with cognitive tests to measure attention, working memory, IQ, and language skills. Such a detailed examination needs to be relatively short and within the technical capability of any suitably qualified professional. Current tests for the presence of AP deficits tend to be poorly constructed and inadequately validated within the normal population. They have little or no reference to the presenting symptoms of the child, and typically include a linguistic component. Poor performance may thus reflect problems with language rather than with AP. To assist in the assessment of children with listening difficulties, pediatric audiologists need a single, standardized child-appropriate test battery based on the use of language-free stimuli. We present the IMAP test battery which was developed at the MRC Institute of Hearing Research to supplement tests currently used to investigate cases of suspected AP deficits. IMAP assesses a range of relevant auditory and cognitive skills and takes about one hour to complete. It has been standardized in 1500 normally-hearing children from across the UK, aged 6-11 years. Since its development, it has been successfully used in a number of large scale studies both in the UK and the USA. IMAP provides measures for separating out sensory from cognitive contributions to hearing. It further limits confounds due to procedural effects by presenting tests in a child-friendly game-format. Stimulus-generation, management of test protocols and control of test presentation is mediated by the IHR-STAR software platform. This provides a standardized methodology for a range of applications and ensures replicable procedures across testers. IHR-STAR provides a flexible, user-programmable environment that currently has additional applications for hearing screening, mapping cochlear implant electrodes, and academic research or teaching.
Wilson, Todd; Chang, Arthur; Berro, Andre; Still, Aaron; Brown, Clive; Demma, Andrew; Nemhauser, Jeffrey; Martin, Colleen; Salame-Alfie, Adela; Fisher-Tyler, Frieda; Smith, Lee; Grady-Erickson, Onalee; Alvarado-Ramy, Francisco; Brunette, Gary; Ansari, Armin; McAdam, David; Marano, Nina
2012-10-01
On March 11, 2011, a magnitude 9.0 earthquake and subsequent tsunami damaged nuclear reactors at the Fukushima Daiichi complex in Japan, resulting in radionuclide release. In response, US officials augmented existing radiological screening at its ports of entry (POEs) to detect and decontaminate travelers contaminated with radioactive materials. During March 12 to 16, radiation screening protocols detected 3 travelers from Japan with external radioactive material contamination at 2 air POEs. Beginning March 23, federal officials collaborated with state and local public health and radiation control authorities to enhance screening and decontamination protocols at POEs. Approximately 543 000 (99%) travelers arriving directly from Japan at 25 US airports were screened for radiation contamination from March 17 to April 30, and no traveler was detected with contamination sufficient to require a large-scale public health response. The response highlighted synergistic collaboration across government levels and leveraged screening methods already in place at POEs, leading to rapid protocol implementation. Policy development, planning, training, and exercising response protocols and the establishment of federal authority to compel decontamination of travelers are needed for future radiological responses. Comparison of resource-intensive screening costs with the public health yield should guide policy decisions, given the historically low frequency of contaminated travelers arriving during radiological disasters.
ERIC Educational Resources Information Center
Niclasen, Janni; Dammeyer, Jesper
2016-01-01
More knowledge is needed about the characteristics of mental health problems among deaf or hard of hearing (D/HH) children. This study investigates the factor structure of one of the most widely used screening tools, the Strengths and Difficulties Questionnaire (SDQ), and the prevalence of mental health problems among D/HH children. Our data were…
Saito, Hideyuki; Nishiwaki, Yuji; Michikawa, Takehiro; Kikuchi, Yuriko; Mizutari, Kunio; Takebayashi, Toru; Ogawa, Kaoru
2010-01-01
To examine the association between hearing handicap and depressive symptoms in older community-dwelling Japanese. Community-based cohort study. Kurabuchi Town, Gunma Prefecture, Japan. Five hundred eighty residents (261 men, 319 women) aged 65 and older without depressive symptoms. In a baseline examination performed in 2005/06, participants answered the 10-item screening version of the Hearing Handicap Inventory for Elderly (HHIE-S). They were divided into two groups according to their scores: a group with no hearing handicap (HHIE-S scores of < or =8) and a hearing handicap group (HHIE-S scores of > or =10). The Geriatric Depression Scale was used to identify depressive symptoms in face-to-face home visit interviews conducted in 2008, and the association between hearing handicap and depressive symptoms was assessed using logistic regression. The incidence of depressive symptoms was 19.6% in the group with a hearing handicap and 8.0% in the group without a hearing handicap. When compared with the subjects without hearing handicap, subjects with a hearing handicap had a multiadjusted odds ratio of depressive symptoms of 2.45 (95% confidence interval=1.26-4.77). The association remained significant even when hearing impairment measured with pure-tone audiometry was added to the multiadjusted model. A hearing handicap can predict future depressive symptoms in older community-dwelling people.
Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka
2016-02-01
To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.
Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka
2016-01-01
Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612
Developing an appropriate digital hearing aid for low-resource countries: a case study.
Israsena, P; Isaradisaikul, S; Noymai, A; Boonyanukul, S; Hemakom, A; Chinnarat, C; Navacharoen, N; Lekagul, S
2013-01-01
This paper reviews the development process and discusses the key findings which resulted from our multidisciplinary research team's effort to develop an alternative digital hearing suitable for low-resource countries such as Thailand. A cost-effective, fully programmable digital hearing aid, with its specifications benchmarking against WHO's recommendations, was systematically designed, engineered, and tested. Clinically it had undergone a full clinical trial that employed the outcome measurement protocol adopted from the APHAB, the first time implemented in Thai language. Results indicated that using the hearing aid improves user's satisfaction in terms of ease of communication, background noises, and reverberation, with clear benefit after 3 and 6 months, confirming its efficacy. In terms of engineering, the hearing aid also proved to be robust, passing all the designated tests. As the technology has successfully been transferred to a local company for the production phase, we also discuss other challenges that may arise before the device can be introduced into the market.
The prevalence of hearing impairment within the Cape Town Metropolitan area
Ramma, Lebogang
2016-01-01
Background There is a lack of data on the prevalence of hearing impairment in South Africa. Current data is unreliable as it is based on national census information which tends to underestimate the prevalence of hearing impairment. Aim The aim of this study was to estimate the prevalence of hearing impairment in the Cape Town Metropolitan area and to determine factors associated with hearing impairment. Method A cross-sectional household survey involving 2494 partcipants from 718 households was conducted between the months of February and October 2013. Random cluster sampling was used to select four health sub-districts from eight health sub-districts in the Cape Town Metropolitan area using a method of probability proportional to size (PPS). The survey was conducted according to the World Health Organization (WHO) Ear and Hearing Disorders Survey Protocol and the classifcation of hearing impairment matched the WHO’s criteria for the grading of hearing impairment. Results The overall prevalence of hearing impairment in the population of this study was 12.35% (95% CI: 11.06% – 13.64%) and prevalence of disabling hearing impairment was 4.57% (95% CI: 3.75% – 5.39%) amongst individuals ≥ 4 years old. The following factors were found to be associated with hearing impairment; male gender, age, hypertension, a history of head and neck trauma and a family history of hearing impairment. Conclusion Based on the data from communities surveyed during this study, hearing impairment is more prevalent than previously estimated based on national population census information. Interventions for the prevention of hearing impairment in these communities should focus on individuals with associated risk factors. PMID:27247255
Uçar, Ahmet; Abacı, Ayhan; Pirgon, Özgür; Dündar, Bumin; Tütüncüler, Filiz; Çatlı, Gönül; Anık, Ahmet; Kılınç Uğurlu, Aylin; Büyükgebiz, Atilla
2018-04-27
A comprehensive survey was conducted courtesy of the Turkish Turner study group to evaluate the shortcomings of clinical care in patients with Turner syndrome (TS) in Turkey. A structured questionnaire prepared by the Turner study group in Turkey, which covers relevant aspects of the care of patients with TS, was sent to all pediatric endocrinology centers. Eighteen centers (41%) returned the questionnaire. In the majority of the centers, diagnostic genetic testing, screening for Y chromosomal material, protocols regarding the timing and posology of growth hormone (GH) and estrogen, thrombophilia screening, fertility information, and screening for glucose intolerance, thyroid, and coeliac diseases in patients with TS were in line with the current consensus. Thirteen centers (72.2%) performed GH stimulation tests. Only four centers (22.2%) used oxandrolone in patients with TS with very short stature. The majority of the centers relied on bone age and breast development to assess estrogen adequacy, though together with variable combinations of oestrogen surrogates. Two centers (11.1%) reported performing serum estradiol measurements. Eight centers (44.4% ) routinely conducted cardiac/thoracic aorta magnetic resonance imaging. Screening for hearing, dental, and ophthalmologic problems were performed by thirteen (72.2%), six (33.3%), and ten (55.6 %) centers, respectively. Psychiatric assessments were made by four centers (22.2%) at diagnosis, with only one center (5.6% ) requiring annual reassessments. Although we found some conformity between the current consensus and practice of the participating centers in Turkey regarding TS, further improvements are mandatory in the multi-disciplinary approach to address co-morbidities, which if unrecognized, may be associated with reduced quality of life, and even mortality.
The Gap-Startle Paradigm for Tinnitus Screening in Animal Models: Limitations and Optimization
Lobarinas, Edward; Hayes, Sarah H.; Allman, Brian L.
2012-01-01
In 2006, Turner and colleagues (Behav Neurosci, 120:188–195) introduced the gap-startle paradigm as a high-throughput method for tinnitus screening in rats. Under this paradigm, gap detection ability was assessed by determining the level of inhibition of the acoustic startle reflex produced by a short silent gap inserted in an otherwise continuous background sound prior to a loud startling stimulus. Animals with tinnitus were expected to show impaired gap detection ability (i.e., lack of inhibition of the acoustic startle reflex) if the background sound containing the gap was qualitatively similar to the tinnitus pitch. Thus, for the gap-startle paradigm to be a valid tool to screen for tinnitus, a robust startle response from which to inhibit must be present. Because recent studies have demonstrated that the acoustic startle reflex could be dramatically reduced following noise exposure, we endeavored to 1) modify the gap-startle paradigm to be more resilient in the presence of hearing loss, and 2) evaluate whether a reduction in startle reactivity could confound the interpretation of gap prepulse inhibition and lead to errors in screening for tinnitus. In the first experiment, the traditional broadband noise (BBN) startle stimulus was replaced by a bandpass noise in which the sound energy was concentrated in the lower frequencies (5–10 kHz) in order to maintain audibility of the startle stimulus after unilateral high frequency noise exposure (16 kHz). However, rats still showed a 57% reduction in startle amplitude to the bandpass noise post-noise exposure. A follow-up experiment on a separate group of rats with transiently-induced conductive hearing loss revealed that startle reactivity was better preserved when the BBN startle stimulus was replaced by a rapid airpuff to the back of the rats neck. Furthermore, it was found that transient unilateral conductive hearing loss, which was not likely to induce tinnitus, caused an impairment in gap prepulse inhibition as assessed with the traditional BBN gap-startle paradigm, resulting in a false-positive screening for tinnitus. Thus, the present study identifies significant caveats of the traditional gap-startle paradigm, and describes experimental parameters using an airpuff startle stimulus which may help to limit the negative consequences of reduced startle reactivity following noise exposure, thereby allowing researchers to better screen for tinnitus in animals with hearing loss. PMID:22728305
Crary, Michael A.; Carnaby, Giselle D.; Sia, Isaac
2017-01-01
Background The aim of this study was to compare spontaneous swallow frequency analysis (SFA) with clinical screening protocols for identification of dysphagia in acute stroke. Methods In all, 62 patients with acute stroke were evaluated for spontaneous swallow frequency rates using a validated acoustic analysis technique. Independent of SFA, these same patients received a routine nurse-administered clinical dysphagia screening as part of standard stroke care. Both screening tools were compared against a validated clinical assessment of dysphagia for acute stroke. In addition, psychometric properties of SFA were compared against published, validated clinical screening protocols. Results Spontaneous SFA differentiates patients with versus without dysphagia after acute stroke. Using a previously identified cut point based on swallows per minute, spontaneous SFA demonstrated superior ability to identify dysphagia cases compared with a nurse-administered clinical screening tool. In addition, spontaneous SFA demonstrated equal or superior psychometric properties to 4 validated, published clinical dysphagia screening tools. Conclusions Spontaneous SFA has high potential to identify dysphagia in acute stroke with psychometric properties equal or superior to clinical screening protocols. PMID:25088166
Crary, Michael A; Carnaby, Giselle D; Sia, Isaac
2014-09-01
The aim of this study was to compare spontaneous swallow frequency analysis (SFA) with clinical screening protocols for identification of dysphagia in acute stroke. In all, 62 patients with acute stroke were evaluated for spontaneous swallow frequency rates using a validated acoustic analysis technique. Independent of SFA, these same patients received a routine nurse-administered clinical dysphagia screening as part of standard stroke care. Both screening tools were compared against a validated clinical assessment of dysphagia for acute stroke. In addition, psychometric properties of SFA were compared against published, validated clinical screening protocols. Spontaneous SFA differentiates patients with versus without dysphagia after acute stroke. Using a previously identified cut point based on swallows per minute, spontaneous SFA demonstrated superior ability to identify dysphagia cases compared with a nurse-administered clinical screening tool. In addition, spontaneous SFA demonstrated equal or superior psychometric properties to 4 validated, published clinical dysphagia screening tools. Spontaneous SFA has high potential to identify dysphagia in acute stroke with psychometric properties equal or superior to clinical screening protocols. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. House Committee on Energy and Commerce.
These hearings addressed cooperative efforts of the United States and the People's Republic of China under the 1979 agreement on science and technology. Thus far, there are more than 20 signed protocols (included in appendices) implementing the agreement in various scientific and technological areas. Activities in such areas as energy, health,…
Cameron, Janette D; Gallagher, Robyn; Pressler, Susan J; McLennan, Skye N; Ski, Chantal F; Tofler, Geoffrey; Thompson, David R
2016-02-01
Cognitive impairment occurs in up to 80% of patients with heart failure (HF). The National Institute for Neurological Disorders and Stroke (NINDS) and the Canadian Stroke Network (CSN) recommend a 5-minute cognitive screening protocol that has yet to be psychometrically evaluated in HF populations. The aim of this study was to conduct a secondary analysis of the sensitivity and specificity of the NINDS-CSN brief cognitive screening protocol in HF patients. The Montreal Cognitive Assessment (MoCA) was administered to 221 HF patients. The NINDS-CSN screen comprises 3 MoCA items, with lower scores indicating poorer cognitive function. Receiver operator characteristic (ROC) curves were constructed, determining the sensitivity, specificity and appropriate cutoff scores of the NINDS-CSN screen. In an HF population aged 76 ± 12 years, 136 (62%) were characterized with cognitive impairment (MoCA <26). Scores on the NINDS-CSN screen ranged from 3-11. The area under the receiver operating characteristic curve indicated good accuracy in screening for cognitive impairment (0.88; P < .01; 95% CI 0.83-0.92). A cutoff score of ≤9 provided 89% sensitivity and 71% specificity. The NINDS-CSN protocol offers clinicians a feasible telephone method to screen for cognitive impairment in patients with HF. Future studies should include a neuropsychologic battery to more comprehensively examine the diagnostic accuracy of brief cognitive screening protocols. Copyright © 2016 Elsevier Inc. All rights reserved.
Vincent, Claude; Gagné, Jean-Pierre; Leroux, Tony; Clothier, Audrey; Larivière, Marianne; Dumont, Frédéric S; Gendron, Martine
2017-04-01
Questionnaires evaluating hearing impairment are available in English but there is a need for French standardised questionnaires for researchers as well as for audiologists and other clinicians. The objective of this study is to describe the translation and validation of four questionnaires that assess different aspects of hearing impairment and handicap among elders with hearing loss, by comparing the main score and psychometric evaluation of original and French-Canadian (FC) versions of the World Health Organization Disability Assessment Scale II (WHO-DAS II), the Screening Test for Hearing Problems (STHP), the Abbreviated Profile of Hearing Aid Benefit (APHAB) and the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids (MARS-HA). Vallerand method: translation and back-translation by two translators, revision by a committee of experts and pre-tested with five bilingual older participants. Participants (n = 29) were 65 years of age or older including 21 with hearing aids. The psychometric properties (internal consistency, temporal stability after four weeks) indicate good reliability for most of the translated questionnaires and their subscales, especially the WHO-DAS II. The translations in FC of two hearing loss and two hearing aid questionnaires were validated. It is recommended to pursue the demonstration for temporal stability for the STHP.
[Using an employee survey as a means of quality assurance in newborn hearing screening].
Depenbrock, A; Matulat, P; am Zehnhoff-Dinnesen, A
2013-03-01
Studies drawing information not only from technical data but also from surveying human resources behind the universal newborn hearing screening (UNHS) appear to be a rarity. This study aims at showing how the state of both knowledge and practical skills among the screening staff are essential aspects in future quality management. A self-developed questionnaire was sent to hospital staff addressing a total of 710 nurses who were registered as having undertaken a UNHS training course. Questions were aimed at aspects of organization, personal practical skills, current problems and improvement possibilities. High rates of occupancy, lack of trained personnel, technical issues and background noise disturbances were considered to be factors that increased time pressure and slowed down procedures. Of the participants 16 % considered communicating a "refer" result to parents a difficult step and 8 % felt insecure when explaining the aims and procedures to parents. There was a high interest in further training sessions. This survey served well to reveal aspects of improvement in screening procedures and meeting staff needs. The training sessions should outline practical aspects of conducting screening and also professional, sensitive communication to parents.
Hearing in Noise Test Brazil: standardization for young adults with normal hearing.
Sbompato, Andressa Forlevise; Corteletti, Lilian Cassia Bornia Jacob; Moret, Adriane de Lima Mortari; Jacob, Regina Tangerino de Souza
2015-01-01
Individuals with the same ability of speech recognition in quiet can have extremely different results in noisy environments. To standardize speech perception in adults with normal hearing in the free field using the Brazilian Hearing in Noise Test. Contemporary, cross-sectional cohort study. 79 adults with normal hearing and without cognitive impairment participated in the study. Lists of Hearing in Noise Test sentences were randomly in quiet, noise front, noise right, and noise left. There were no significant differences between right and left ears at all frequencies tested (paired t-1 test). Nor were significant differences observed when comparing gender and interaction between these conditions. A difference was observed among the free field positions tested, except in the situations of noise right and noise left. Results of speech perception in adults with normal hearing in the free field during different listening situations in noise indicated poorer performance during the condition with noise and speech in front, i.e., 0°/0°. The values found in the standardization of the Hearing in Noise Test free field can be used as a reference in the development of protocols for tests of speech perception in noise, and for monitoring individuals with hearing impairment. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
A Cost Analysis of a Pancreatic Cancer Screening Protocol in High-Risk Populations
Bruenderman, Elizabeth; Martin, Robert CG
2016-01-01
Background Pancreatic cancer is the 4th leading cause of cancer death in the U.S. A screening protocol is needed to catch early stage, resectable disease. This study suggests a protocol for high-risk individuals and assesses the cost in the context of the Affordable Care Act. Methods Medicare and national average pricing were used for cost analysis of a protocol using MRI/MRCP biannually in high-risk groups. Results: ‘ Costs per year of life added’ based on Medicare and national average costs, respectively, are: $638.62 and $2542.37 for Peutz-Jehgers Syndrome, $945.33 and $3763.44 for Hereditary Pancreatitis, $1141.77 and $4545.45 for Familial Pancreatic Cancer and p16-Leiden mutations, and $356.42 and $1418.92 for new-onset diabetes over age 50 with weight loss or smoking. Conclusion A screening program using MRI/MRCP is affordable in high-risk populations. The U.S. Preventive Services Task Force must reevaluate its pancreatic cancer screening guidelines to make screening more cost-effective for the individual. PMID:26003200
Randomized Comparison of 3 Methods to Screen for Domestic Violence in Family Practice
Chen, Ping-Hsin; Rovi, Sue; Washington, Judy; Jacobs, Abbie; Vega, Marielos; Pan, Ko-Yu; Johnson, Mark S.
2007-01-01
PURPOSE We undertook a study to compare 3 ways of administering brief domestic violence screening questionnaires: self-administered questionnaire, medical staff interview, and physician interview. METHODS We conducted a randomized trial of 3 screening protocols for domestic violence in 4 urban family medicine practices with mostly minority patients. We randomly assigned 523 female patients, aged 18 years or older and currently involved with a partner, to 1 of 3 screening protocols. Each included 2 brief screening tools: HITS and WAST-Short. Outcome measures were domestic violence disclosure, patient and clinician comfort with the screening, and time spent screening. RESULTS Overall prevalence of domestic violence was 14%. Most patients (93.4%) and clinicians (84.5%) were comfortable with the screening questions and method of administering them. Average time spent screening was 4.4 minutes. Disclosure rates, patient and clinician comfort with screening, and time spent screening were similar among the 3 protocols. In addition, WAST-Short was validated in this sample of minority women by comparison with HITS and with the 8-item WAST. CONCLUSIONS Domestic violence is common, and we found that most patients and clinicians are comfortable with domestic violence screening in urban family medicine settings. Patient self-administered domestic violence screening is as effective as clinician interview in terms of disclosure, comfort, and time spent screening. PMID:17893385
Acoustic Reflex Testing in Neonatal Hearing Screening and Subsequent Audiological Evaluation.
Jacob-Corteletti, Lilian Cássia Bórnia; Araújo, Eliene Silva; Duarte, Josilene Luciene; Zucki, Fernanda; Alvarenga, Kátia de Freitas
2018-06-18
The aims of the study were to examine the acoustic reflex screening and threshold in healthy neonates and those at risk of hearing loss and to determine the effect of birth weight and gestational age on acoustic stapedial reflex (ASR). We assessed 18 healthy neonates (Group I) and 16 with at least 1 risk factor for hearing loss (Group II); all of them passed the transient evoked otoacoustic emission test that assessed neonatal hearing. The test battery included an acoustic reflex screening with activators of 0.5, 1, 2, and 4 kHz and broadband noise and an acoustic reflex threshold test with all of them, except for the broadband noise activator. In the evaluated neonates, the main risk factors were the gestational age at birth and a low birth weight; hence, these were further analyzed. The lower the gestational age at birth and birth weight, the less likely that an acoustic reflex would be elicited by pure-tone activators. This effect was significant at the frequencies of 0.5, 1, and 2 kHz for gestational age at birth and at the frequencies of 1 and 2 kHz for birth weight. When the broadband noise stimulus was used, a response was elicited in all neonates in both groups. When the pure-tone stimulus was used, the Group II showed the highest acoustic reflex thresholds and the highest percentage of cases with an absent ASR. The ASR threshold varied from 50 to 100 dB HL in both groups. Group II presented higher mean ASR thresholds than Group I, this difference being significant at frequencies of 1, 2, and 4 kHz. Birth weight and gestational age at birth were related to the elicitation of the acoustic reflex. Neonates with these risk factors for hearing impairment were less likely to exhibit the acoustic reflex and had higher thresholds.
Progressive Hearing Loss in Mice Carrying a Mutation in Usp53
Kazmierczak, Marcin; Harris, Suzan L.; Kazmierczak, Piotr; Shah, Prahar; Starovoytov, Valentin; Ohlemiller, Kevin K.
2015-01-01
Disordered protein ubiquitination has been linked to neurodegenerative disease, yet its role in inner ear homeostasis and hearing loss is essentially unknown. Here we show that progressive hearing loss in the ethylnitrosourea-generated mambo mouse line is caused by a mutation in Usp53, a member of the deubiquitinating enzyme family. USP53 contains a catalytically inactive ubiquitin-specific protease domain and is expressed in cochlear hair cells and a subset of supporting cells. Although hair cell differentiation is unaffected in mambo mice, outer hair cells degenerate rapidly after the first postnatal week. USP53 colocalizes and interacts with the tight junction scaffolding proteins TJP1 and TJP2 in polarized epithelial cells, suggesting that USP53 is part of the tight junction complex. The barrier properties of tight junctions of the stria vascularis appeared intact in a biotin tracer assay, but the endocochlear potential is reduced in adult mambo mice. Hair cell degeneration in mambo mice precedes endocochlear potential decline and is rescued in cochlear organotypic cultures in low potassium milieu, indicating that hair cell loss is triggered by extracellular factors. Remarkably, heterozygous mambo mice show increased susceptibility to noise injury at high frequencies. We conclude that USP53 is a novel tight junction-associated protein that is essential for the survival of auditory hair cells and normal hearing in mice, possibly by modulating the barrier properties and mechanical stability of tight junctions. SIGNIFICANCE STATEMENT Hereditary hearing loss is extremely prevalent in the human population, but many genes linked to hearing loss remain to be discovered. Forward genetics screens in mice have facilitated the identification of genes involved in sensory perception and provided valuable animal models for hearing loss in humans. This involves introducing random mutations in mice, screening the mice for hearing defects, and mapping the causative mutation. Here, we have identified a mutation in the Usp53 gene that causes progressive hearing loss in the mambo mouse line. We demonstrate that USP53 is a catalytically inactive deubiquitinating enzyme and a novel component of tight junctions that is necessary for sensory hair cell survival and inner ear homeostasis. PMID:26609154
Scheper, Verena; Leifholz, Melanie; von der Leyen, Heiko; Keller, Miriam; Denkena, Ute; Koch, Armin; Karch, Annika; Miller, Josef; Lenarz, Thomas
2016-08-08
The indications for a cochlear implant (CI) have been extended to include patients with some residual hearing. Shorter and thinner atraumatic electrodes have been designed to preserve the residual hearing in the implanted ear. However, the insertion of the electrode array into the cochlea, with potential mechanical trauma and the presence of this foreign body inside the cochlea, may lead to free radical formation and reduced blood perfusion of the cochlea which can result in the loss of residual hearing. In this single-center, randomized, placebo-controlled, double-blind phase II clinical trial the effect of free radical scavengers and a vasodilator on the residual hearing of 140 CI patients will be evaluated. The formulation is composed of β-carotene (vitamin A), ascorbic acid (vitamin C), dl-α-tocopherol acetate (vitamin E) and the vasodilator magnesium (Mg), or ACEMg. Medication is administered twice daily per os for approximately 3 months. The primary measure is based upon the reduction in postoperative low-frequency air-conducted pure-tone thresholds compared to preoperative thresholds in ACEMg-treated patients compared to those of a placebo group. Additionally, the effect of different electrode lengths (20, 24 and 28 mm) is analyzed. Study visits are scheduled 2 days before surgery, at first fitting, which is the adjustment and start of stimulation via CI 4 weeks after surgery and 3, 6, 9 and 12 months after first fitting. The primary endpoint is the air-conduction hearing loss at 500 Hz 3 months after first fitting. Additionally, speech recognition tests, hearing aid benefit in the implanted ear and electrophysiological measurements of implant function are assessed. Since this is a blinded clinical trial and recruitment is still ongoing, data continue to accrue and we cannot yet analyze the outcome of the ACEMg treatment. There is an unfulfilled need for new strategies to preserve acoustic hearing in CI patients. This study will provide first-in-man data on ACEMg-mediated protection of residual hearing in CI patients. Performing all surgeries and patient follow-up at one study site improves consistency in diagnosis and therapy and less variability in surgery, audiological test techniques and fitting. This approach will allow investigation of the influence of ACEMg on residual hearing in CI patients. The German Bundesinstitut für Arzneimittel und Medizinprodukte (BfArM) application number 4039192, was registered on 6 December 2013 with protocol amendment version 3.0 from 19 August 2014. EudraCT number: 2012-005002-22 .
Evaluation of very low birth weight (≤ 1,500 g) as a risk indicator for sensorineural hearing loss.
Borkoski-Barreiro, Silvia A; Falcón-González, Juan C; Limiñana-Cañal, José M; Ramos-Macías, Angel
2013-01-01
Hearing plays an essential role in the acquisition, development and maintenance of the properties of the speech and language. Birth weight is an indicator of biological maturation of the newborn. Premature newborns with very low birth weight (VLBW<1,500 g) constitute a group with the highest risk of sensorineural hearing loss. Our objective was to ascertain the degree of hearing loss, sensorineural hearing loss and presence of the association to other risk factors for hearing loss in VLBW infants included in the Universal Hearing Loss Screening Programme at the University Mother-Child Hospital of Gran Canaria (Spain) in the 2007-2010 period. This was a retrospective study of 364 infants with VLBW, measured by transient evoked otoacoustic emissions and auditory brainstem response. There were 112 newborn (30.8%) referred for auditory brainstem response. A diagnosis of hearing loss was given to 22 newborns (2.2%), 14 had conductive hearing loss and 8, sensorineural hearing loss (SNHL), of which 2 had bilateral profound hearing loss. The VLBW newborn presented the association to another risk factor in more than a quarter of the sample studied. All those diagnosed with SNHL were premature. The percentage of VLBW newborns diagnosed with hearing loss is higher than expected in the general population. All those diagnosed with SNHL were premature and presented one or 2 hearing risk factors associated with VLBW. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Screening Protocol for Early Identification of Brazilian Children at Risk for Dyslexia
Germano, Giseli D.; César, Alexandra B. P. de C.; Capellini, Simone A.
2017-01-01
Early identification of students at risk of dyslexia has been an educational challenge in the past years. This research had two main goals. First, we aimed to develop a screening protocol for early identification of Brazilian children at risk for dyslexia; second, we aimed to identify the predictive variables of this protocol using Principal Component Analysis. The major step involved in developing this protocol was the selection of variables, which were chosen based on the literature review and linguistic criteria. The screening protocol was composed of seven cognitive-linguistic skills: Letter naming; Phonological Awareness (which comprises the following subtests: Rhyme production, Rhyme identification, Syllabic segmentation, Production of words from a given phoneme, Phonemic Synthesis, and Phonemic analysis); Phonological Working memory, Rapid naming Speed; Silent reading; Reading of words and non-words; and Auditory Comprehension of sentences from pictures. A total of 149 children, aged from 6 years to 6 and 11, of both genders who were enrolled in the 1st grade of elementary public schools were submitted to the screening protocol. Principal Component Analysis revealed four factors, accounting for 64.45% of the variance of the Protocol variables: first factor (“pre-reading”), second factor (“decoding”), third factor (“Reading”), and fourth factor “Auditory processing.” The factors found corroborate those reported in the National and International literature and have been described as early signs of dyslexia and reading problems. PMID:29163246
SU-E-P-03: Implementing a Low Dose Lung Screening CT Program Meeting Regulatory Requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFrance, M; Marsh, S; O'Donnell, G
Purpose: To provide information pertaining to IROC Houston QA Center's (RPC) credentialing process for institutions participating in NCI-sponsored clinical trials. Purpose: Provide guidance to the Radiology Departments with the intent of implementing a Low Dose CT Screening Program using different CT Scanners with multiple techniques within the framework of the required state regulations. Method: State Requirements for the purpose of implementing a Low Dose CT Lung Protocol required working with the Radiology and Pulmonary Department in setting up a Low Dose Screening Protocol designed to reduce the radiation burden to the patients enrolled. Radiation dose measurements (CTDIvol) for various CTmore » manufacturers (Siemens16, Siemens 64, Philips 64, and Neusoft128) for three different weight based protocols. All scans were reviewed by the Radiologist. Prior to starting a low dose lung screening protocol, information had to be submitted to the state for approval. Performing a Healing Arts protocol requires extensive information. This not only includes name and address of the applicant but a detailed description of the disease, the x-ray examination and the population to be examined. The unit had to be tested by a qualified expert using the technique charts. The credentials of all the operators, the supervisors and the Radiologists had to be submitted to the state. Results: All the appropriate documentation was sent to the state for review. The measured results between the Low Dose Protocol versus the default Adult Chest Protocol showed that there was a dose reduction of 65% for small (100-150 lb.) patient, 75% for the Medium patient (151-250 lbs.), and a 55% reduction for the Large patient ( over 250 lbs.). Conclusion: Measured results indicated that the Low Dose Protocol indeed lowered the screening patient's radiation dose and the institution was able to submit the protocol to the State's regulators.« less
Overview of a public health approach to pediatric hearing impairment in the Pacific Islands.
Kaspar, Annette; Kei, Joseph; Driscoll, Carlie; Swanepoel, De Wet; Goulios, Helen
2016-07-01
Childhood hearing impairment is a significant cause of disability in developing countries. Otitis media and meningitis are leading infectious causes of preventable hearing loss in children. It is estimated that the Pacific Islands have among the greatest global burden of childhood hearing impairment due to infectious causes, and yet there is currently very little in the research literature on pediatric hearing disorders in this region. (1) To review existing research literature on pediatric hearing impairment in the Pacific Islands, and (2) to present a public health approach to the development and improvement of childhood hearing services in the Pacific Islands. The primary tool was a comprehensive literature review. MEDLINE and ScienceDirect databases were searched for relevant journal articles. There was no limit on the date of publication. Any article reporting on hearing impairment in the Pacific Region was included. A total of 23 journal articles were found that satisfied the above inclusion criteria. The limited information available in the literature suggests that otitis media and vaccine-preventable infections are a significant cause of avoidable childhood hearing impairment in the Pacific Islands. Pediatric audiology services are limited in this region. Further research is required to develop effective public health programs that should reduce the burden of preventable childhood hearing loss in the Pacific Islands. There is limited information in the research literature on pediatric hearing impairment and audiology services in the Pacific Islands. Epidemiological data based on the WHO Ear and Hearing Disorders Survey Protocol are urgently needed, and the development of audiology services within the existing public and primary health care framework should reduce the burden of preventable hearing loss in the Pacific Islands. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kaspar, Annette; Newton, Obiga; Kei, Joseph; Driscoll, Carlie; Swanepoel, De Wet; Goulios, Helen
2017-12-01
An understanding of parental knowledge and attitudes towards childhood hearing loss is essential to the successful implementation of audiology services. The present study aimed to investigate parental knowledge and attitudes among parents in the Solomon Islands. A total of 100 mothers and 50 fathers were administered a questionnaire via semi-structured interviews. Highest parental awareness of aetiology of childhood hearing loss was noted for otitis media (94%), noise exposure (87.3%), and family history (72.7%). The highest parental awareness concerning public health initiatives to reduce/prevent otitis media was noted for routine childhood immunizations (84%) and breast-feeding (76%). Higher rates of knowledge in fathers than in mothers included otitis media (p = 0.038), noise exposure (p = 0.007), and breast-feeding (p = 0.031). Approximately half of parents (56%) agreed that curses may cause hearing loss. Overall parental responses showed positive support for infant hearing screening programs (96%) and school-based ear and hearing health examinations (99.3%). High levels of parental readiness and support for childhood hearing services in the Solomon Islands was evident. Knowledge of aetiology of childhood hearing loss was highest for otitis media, noise exposure, and family history. Knowledge and attitudes of fathers to childhood hearing loss and hearing services was either the same or better than that of mothers. Copyright © 2017 Elsevier B.V. All rights reserved.
The objective of this research is to develop in vivo screening protocols for endocrine disruption in marine crustaceans, invertebrates of ecological and economic importance. A series of comparative developmental and reproductive studies were performed on several species of estuar...
Leal, Mariana C; Muniz, Lilian F; Ferreira, Tamires S A; Santos, Cristiane M; Almeida, Luciana C; Van Der Linden, Vanessa; Ramos, Regina C F; Rodrigues, Laura C; Neto, Silvio S Caldas
2016-09-02
Congenital infection with Zika virus causes microcephaly and other brain abnormalities (1). Hearing loss associated with other congenital viral infections is well described; however, little is known about hearing loss in infants with congenital Zika virus infection. A retrospective assessment of a series of 70 infants aged 0-10 months with microcephaly and laboratory evidence of Zika virus infection was conducted by the Hospital Agamenon Magalhães in Brazil and partners. The infants were enrolled during November 2015-May 2016 and had screening and diagnostic hearing tests. Five (7%) infants had sensorineural hearing loss, all of whom had severe microcephaly; however, one child was tested after receiving treatment with an ototoxic antibiotic. If this child is excluded, the prevalence of sensorineural hearing loss was 5.8% (four of 69), which is similar to that seen in association with other congenital viral infections. Additional information is needed to understand the prevalence and spectrum of hearing loss in children with congenital Zika virus infection; all infants born to women with evidence of Zika virus infection during pregnancy should have their hearing tested, including infants who appear normal at birth.
Scholes, Shaun; Biddulph, Jane; Davis, Adrian; Mindell, Jennifer S.
2018-01-01
Background Hearing loss impacts on cognitive, social and physical functioning. Both hearing loss and hearing aid use vary across population subgroups. We examined whether hearing loss, and reported current hearing aid use among persons with hearing loss, were associated with different markers of socioeconomic status (SES) in a nationally representative sample of community-dwelling middle-aged and older adults. Methods Hearing was measured using an audiometric screening device in the Health Survey for England 2014 (3292 participants aged 45 years and over). Hearing loss was defined as >35 dB HL at 3.0 kHz in the better-hearing ear. Using sex-specific logistic regression modelling, we evaluated the associations between SES and hearing after adjustment for potential confounders. Results 26% of men and 20% of women aged 45 years and over had hearing loss. Hearing loss was higher among men in the lowest SES groups. For example, the multivariable-adjusted odds of hearing loss were almost two times as high for those in the lowest versus the highest income tertile (OR 1.77, 95% CI 1.15 to 2.74). Among those with hearing loss, 30% of men and 27% of women were currently using a hearing aid. Compared with men in the highest income tertile, the multivariable-adjusted odds of using a hearing aid nowadays were lower for men in the middle (OR 0.50, 95% CI 0.25 to 0.99) and the lowest (OR 0.47, 95% CI 0.23 to 0.97) income tertiles. Associations between SES and hearing were weaker or null among women. Conclusions While the burden of hearing loss fell highest among men in the lowest SES groups, current hearing aid use was demonstrably lower. Initiatives to detect hearing loss early and increase the uptake and the use of hearing aids may provide substantial public health benefits and reduce socioeconomic inequalities in health. PMID:29391384
A Protocol for Decellularizing Mouse Cochleae for Inner Ear Tissue Engineering.
Neal, Christopher A; Nelson-Brantley, Jennifer G; Detamore, Michael S; Staecker, Hinrich; Mellott, Adam J
2018-01-01
In mammals, mechanosensory hair cells that facilitate hearing lack the ability to regenerate, which has limited treatments for hearing loss. Current regenerative medicine strategies have focused on transplanting stem cells or genetic manipulation of surrounding support cells in the inner ear to encourage replacement of damaged stem cells to correct hearing loss. Yet, the extracellular matrix (ECM) may play a vital role in inducing and maintaining function of hair cells, and has not been well investigated. Using the cochlear ECM as a scaffold to grow adult stem cells may provide unique insights into how the composition and architecture of the extracellular environment aids cells in sustaining hearing function. Here we present a method for isolating and decellularizing cochleae from mice to use as scaffolds accepting perfused adult stem cells. In the current protocol, cochleae are isolated from euthanized mice, decellularized, and decalcified. Afterward, human Wharton's jelly cells (hWJCs) that were isolated from the umbilical cord were carefully perfused into each cochlea. The cochleae were used as bioreactors, and cells were cultured for 30 days before undergoing processing for analysis. Decellularized cochleae retained identifiable extracellular structures, but did not reveal the presence of cells or noticeable fragments of DNA. Cells perfused into the cochlea invaded most of the interior and exterior of the cochlea and grew without incident over a duration of 30 days. Thus, the current method can be used to study how cochlear ECM affects cell development and behavior.
Mamon, J; Green, L; Levine, D M; Gibson, G; Gurley, H T
1987-08-01
This study describes the development and testing of a high blood pressure protocol for use in emergency departments (ED) to enhance detection of those patients appropriate for subsequent referral. The protocol involves two serial blood pressure measurements and a patient interview to determine: 1) previous history of high blood pressure (HBP), 2) treatment in past year for HBP, and 3) usual source of medical care. The accuracy of patient reporting was validated by comparison with the patients' hospital record (reflecting outpatient and inpatient visits). Results indicate that these self-reports have high levels of sensitivity (range 90-100%) and specificity (range 79-96%). Use of the additional patient information increased the sensitivity of the screening protocol in identifying when and where a patient should be referred. Use of this methodology indicates that the protocol is a simple and effective method for HBP screening. The findings also suggest that the ED is an ideal site for screening the "hard-to-reach" hypertensive population.
Characteristics of children with unilateral hearing loss.
Fitzpatrick, Elizabeth M; Al-Essa, Rakan S; Whittingham, JoAnne; Fitzpatrick, Jessica
2017-11-01
The purpose of this study was to describe the clinical characteristics of children with unilateral hearing loss (UHL), examine deterioration in hearing, and explore amplification decisions. Population-based data were collected prospectively from time of diagnosis. Serial audiograms and amplification details were retrospectively extracted from clinical charts to document the trajectory and management of hearing loss. The study included all children identified with UHL in one region of Canada over a 13-year period (2003-2015) after implementation of universal newborn hearing screening. Of 537 children with permanent hearing loss, 20.1% (108) presented with UHL at diagnosis. They were identified at a median age of 13.9 months (IQR: 2.8, 49.0). Children with congenital loss were identified at 2.8 months (IQR: 2.0, 3.6) and made up 47.2% (n = 51), reflecting that a substantial portion had late-onset, acquired or late-identified loss. A total of 42.4% (n = 39) showed deterioration in hearing, including 16 (17.4%) who developed bilateral loss. By study end, 73.1% (79/108) of children had received amplification recommendations. Up to 20% of children with permanent HL are first diagnosed with UHL. About 40% are at risk for deterioration in hearing either in the impaired ear and/or in the normal hearing ear.
2016-10-01
approval and initiated advertising , recruitment, participant screening, participant enrollment, and the study protocol. All start up subtasks have been...be made to enroll these during the next reporting period. Advertisement , recruitment, screening, and enrollment are ongoing as we work toward the...Regulatory Approvals 100% Completed. • Task 3: Start up 100% Completed. Milestone: Protocol ready to begin—Completed • Task 4: Advertisement 40
2006-01-01
Environmental Protection Agency (USEPA) Endocrine Disruptor Screening and Testing Program. The frogs were exposed to the model anti- androgenic...the study were to develop a protocol that could be used for a standard U.S. EPA testing procedure in the Endocrine Disruptor Screening and Testing...compounds. As a consequence of this requirement, the USEPA established an Endocrine Disruptor Screening and Testing Advisory Committee (EDSTAC
Physician Nonadherence With a Hepatitis C Screening Program
Southern, William N.; Drainoni, Mari-Lynn; Smith, Bryce D.; Koppelman, Elisa; McKee, M. Diane; Christiansen, Cindy L.; Gifford, Allen L.; Weinbaum, Cindy M.; Litwin, Alain H.
2017-01-01
Background Testing for patients at risk for hepatitis C virus (HCV) infection is recommended, but it is unclear whether providers adhere to testing guidelines. We aimed to measure adherence to an HCV screening protocol during a multifaceted continuous intervention. Subjects and Methods Prospective cohort design to examine the associations between patient-level, physician-level, and visit-level characteristics and adherence to an HCV screening protocol. Study participants included all patients with a visit to 1 of the 3 study clinics and the physicians who cared for them. Adherence to the HCV screening protocol and patient-level, physician-level, and visit-level predictors of adherence were measured. Results A total of 8981 patients and 154 physicians were examined. Overall protocol adherence rate was 36.1%. In multivariate analysis, patient male sex (odds ratio [OR] = 1.18), new patient (OR = 1.23), morning visit (OR = 1.32), and patients’ preferred language being non-English (OR = 0.87) were significantly associated with screening adherence. There was a wide variation in overall adherence among physicians (range, 0%–92.4%). Screening adherence continuously declined from 59.1% in week 1 of the study to 13.7% in week 15 (final week). When implementing complex clinical practice guidelines, planners should address physician attitudinal barriers as well as gaps in knowledge to maximize adherence. PMID:24368717
Gu, Xiaodong; Su, Wenling; Tang, Mingliang; Guo, Luo; Zhao, Liping
2016-01-01
DFNA9 is a late-onset, progressive, autosomal dominantly inherited sensorineural hearing loss with vestibular dysfunction, which is caused by mutations in the COCH (coagulation factor C homology) gene. In this study, we investigated a Chinese family segregating autosomal dominant nonsyndromic sensorineural hearing loss. We identified a missense mutation c.T275A p.V92D in the LCCL domain of COCH cosegregating with the disease and absent in 100 normal hearing controls. This mutation leads to substitution of the hydrophobic valine to an acidic amino acid aspartic acid. Our data enriched the mutation spectrum of DFNA9 and implied the importance for mutation screening of COCH in age related hearing loss with vestibular dysfunctions. PMID:28116169
MOLINI, E.; CRISTI, M.C.
2016-01-01
SUMMARY The Universal Newborn Hearing Screening (UNHS) programme aims at achieving early detection of hearing impairment. Subsequent diagnosis and intervention should follow promptly. Within the framework of the Ministry of Health project CCM 2013 "Preventing Communication Disorders: a Regional Program for early Identification, Intervention and Care of Hearing Impaired Children", the limitations and strengths of current UNHS programs in Italy have been analysed by a group of professionals working in tertiary centres involved in regional UNHS programmes, using SWOT analysis and a subsequent TOWS matrix. Coverage and lost-to-follow up rates are issues related to UNHS programmes. Recommendations to improve the effectiveness of the UNHS programme have been identified. The need for homogeneous policies, high-quality information and dissemination of knowledge for operators and families of hearing-impaired children emerged from the discussion. PMID:27054385
Meijerink, Janine FJ; Pronk, Marieke; Paulissen, Bernadette; Witte, Birgit I; van der Wouden, Bregje; Jansen, Vera; Kramer, Sophia E
2017-01-01
Background An educational SUpport PRogramme called SUPR has been developed for hearing aid users (HAUs) and their communication partners (CPs) offering care beyond hearing aid fitting. SUPR teaches its users communication strategies, hearing aid handling skills and personal adjustment to hearing impairment. Methods/design Using a cluster randomised controlled trial design, 70 Dutch hearing aid dispenser practices were randomised into hearing aid fitting (care as usual, 34 practices) and hearing aid fitting including SUPR (36 practices). The aim was to recruit a total of 569 older (aged 50+ years) first-time (n=258) and experienced (n=311) HAUs and their CPs. SUPR consists of a Practical Support Booklet and online material offered via email over a period of 6–7 months. The booklet provides practical information on hearing aids, advice on communication strategies and home exercises. The online material consists of educational videos on hearing aid functionality and usage, communication strategies and peer testimonials. Finally, noncommittal email contact with the dispenser is offered. Every HAU is asked to assign a CP who is advised to be involved intensively. Effect measurements for HAUs and their CPs will occur at baseline and at 6, 12 and 18 months follow-up via online questionnaires. The primary outcomes for HAUs will be the use of communication strategies as measured by the subscales of the Communication Profile for the Hearing Impaired. A process evaluation will be performed. Ethics and dissemination The study was approved by the Dutch Institutional Review Board of the VU Medical University Center Amsterdam. This intervention could contribute to lowering the hearing impairment burden in our ageing society. The results will be disseminated through peer-reviewed publications and scientific conferences. Trial registration number ISRCTN77340339; Pre-results. PMID:28634259
Omondi, Dickens; Ogol, Calistus; Otieno, Syprine; Macharia, Isaac
2007-03-01
Hearing-impaired children who are identified early and appropriately managed have improved outcomes in speech, language, cognitive and social development. Enhanced parental awareness of their child's hearing disability, behavioral, developmental and psychosocial limitations is essential to sustaining timely detection and appropriate intervention. Additionally, availability of services for diagnosis, treatment and habilitation would improve the demand for pedaudiological care in this community. To describe level of parental awareness of childhood HI and the pattern of access to and utilization of ambulatory care services. Thirty-three parents of lower primary school-going children who failed audiometric screening from sampled schools in Kisumu district, western Kenya. First person to detect HI, age of child at first suspicion of HI, source of ambulatory health care and use of the health care facilities. The prevalence of HI was 2.48%. Most parents/guardians (69.7%) were aware of their child's hearing impairment. Of these, 63.6% were first to detect HI in the pupils, while 30.3% were detected by screen. Most children (57.2%) were first recognized with (HI) after age 2 years. The mean age at identification was 5.5 years. The median travel distance to the preferred health care facility was 2 km (IQR 1-2.5). Parents seldom sought or lacked help for their hearing-impaired children. Of 27.3% who asked for hearing assessment, 9.1% received some counsel on HI and 12.1% received medication, one (3%) was referred for audiological assessment and none used a hearing aid. Use of health facilities for maternal care was (65.7%) and immunization (62.9%). Despite adequate parental awareness of chronic childhood disability, health facilities were underutilized. This indicates the need to further stimulate and maintain a desirable level of uptake of services for diagnosis, treatment and habilitation of childhood HI, while sustaining delivery of effective and acceptable high quality paediatric care.
Yeung, Jeffrey C; Heley, Sophie; Beauregard, Yves; Champagne, Sandra; Bromwich, Matthew A
2015-08-01
The timely diagnosis and treatment of acquired hearing loss in the pediatric population has significant implications for a child's development. Audiological assessment in children, however, carries both technological and logistical challenges. Typically, specialized methods (such as play audiometry) are required to maintain the child's attention and can be resource intensive. These challenges were previously addressed by a novel, calibrated, interactive play audiometer for Apple(®) iOS(®) called "ShoeBOX Audiometry". This device has potential applications for deployment in environments where traditional clinical audiometry is either unavailable or impractical. The objective of this study was to assess the screening capability of the tablet audiometer in an uncontrolled environment using consumer ear-bud headphones. Consecutive patients presenting to the Audiology Clinic at the Children's Hospital of Eastern Ontario (ages 4 and older) were recruited. Participants' hearing was evaluted using the tablet audiometer calibrated to Apple(®) In-Ear headphones. The warble tone thresholds obtained were compared to gold standard measurements taken with a traditional clinical audiometer inside a soundbooth. 80 patients were enrolled. The majority of participants were capable of completing an audiologic assessment using the tablet computer. Due to ambient noise levels outside a soundbooth, thresholds obtained at 500Hz were not consistent with traditional audiometry. Excluding 500Hz threholds, the tablet audiometer demonstrated strong negative predictive value (89.7%) as well as strong sensitivity (91.2%) for hearing loss. Thresholds obtained in an uncontrolled setting are not reflective of diagnostic thresholds due to the uncalibrated nature of the headphones and variability of the setting without a booth. Nevertheless, the tablet audiometer proved to be both a valid and sensitive instrument for unsupervised screening of warble-tone thresholds in children. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Tikka, T; Mistry, N; Janjua, A
2016-03-01
Unilateral sudden sensorineural hearing loss due to an infarct in the vertebrobasilar system has been widely reported. Most patients have a background of traditional coronary risk factors related to these cerebrovascular episodes. A 32-year-old male, a regular user of anabolic steroids, presented to the emergency department with unilateral sensorineural hearing loss and symptoms suggestive of an infarct of the anterior inferior cerebellar artery but in the absence of risk factors for ischaemic stroke. Magnetic resonance imaging confirmed the presence of infarction in the region supplied by the anterior inferior cerebellar artery. Polycythaemia was found on haematological analysis, which we believe was secondary to the use of anabolic steroids. The patient was commenced on aspirin as per the stroke management protocol. There was resolution of neurological symptomatology six weeks after the episode, but no improvement in hearing. To our knowledge, this is the first case report of unilateral sensorineural hearing loss secondary to the use of anabolic steroids causing polycythaemia. This cause should be considered in the differential diagnosis of patients presenting with sensorineural hearing loss, especially in young males, when no other risk factors can be identified.
Mikkola, Tuija M; Polku, Hannele; Sainio, Päivi; Koponen, Päivikki; Koskinen, Seppo; Viljanen, Anne
2016-11-08
Older adults with hearing difficulties face problems of communication which may lead to underuse of health services. This study investigated the association of hearing loss and self-reported hearing difficulty with the use of health services and unmet health care needs in older adults. Data on persons aged 65 and older (n = 2144) drawn from a population-based study, Health 2000, were analyzed. Hearing loss was determined with screening audiometry (n = 1680). Structured face-to-face interviews were used to assess self-reported hearing difficulty (n = 1962), use of health services (physician and nurse visits, health examinations, mental health services, physical therapy, health promotion groups, vision test, hearing test, mammography, PSA test) and perceived unmet health care needs. Multivariable logistic regression analyses were used. After adjusting for socio-economic and health-related confounders, persons with hearing loss (hearing level of better ear 0.5-2 kHz > 40 dB) were more likely to have used mental health services than those with non-impaired hearing (OR = 3.2, 95 % CI 1.3-7.9). Self-reported hearing difficulty was also associated with higher odds for mental health service use (OR = 2.1 95 % CI 1.2-3.5). Hearing was not associated with use of the other health services studied, except presenting for a hearing test. Persons with self-reported hearing difficulty were more likely to perceive unmet health care needs than those without hearing difficulty (OR = 1.7, 95 % CI 1.4-2.1). Older adults with hearing loss or self-reported hearing difficulty are as likely to use most health services as those without hearing loss. However, self-reported hearing difficulty is associated with experiencing unmet health care needs. Adequate health services should be ensured for older adults with hearing difficulties.
Turğut, Nedim; Karlıdağ, Turgut; Başar, Figen; Yalçın, Şinasi; Kaygusuz, İrfan; Keleş, Erol; Birkent, Ömer Faruk
2015-01-01
This study aims to review the relationship between written language skills and factors which are thought to affect this skill such as mean hearing loss, duration of auditory deprivation, speech discrimination score, and pre-school education attendance and socioeconomic status of hearing impaired children who attend 4th-7th grades in primary school in inclusive environment. The study included 25 hearing impaired children (14 males, 11 females; mean age 11.4±1.4 years; range 10 to 14 years) (study group) and 20 children (9 males, 11 females; mean age 11.5±1.3 years; range 10 to 14 years) (control group) with normal hearing in the same age group and studying in the same class. Study group was separated into two subgroups as group 1a and group 1b since some of the children with hearing disability used hearing aid while some used cochlear implant. Intragroup comparisons and relational screening were performed for those who use hearing aids and cochlear implants. Intergroup comparisons were performed to evaluate the effect of the parameters on written language skills. Written expression skill level of children with hearing disability was significantly lower than their normal hearing peers (p=0.001). A significant relationship was detected between written language skills and mean hearing loss (p=0.048), duration of auditory deprivation (p=0.021), speech discrimination score (p=0.014), and preschool attendance (p=0.005), when it comes to socioeconomic status we were not able to find any significant relationship (p=0.636). It can be said that hearing loss affects written language skills negatively and hearing impaired individuals develop low-level written language skills compared to their normal hearing peers.
Development of an HPV Educational Protocol for Adolescents
Wetzel, Caitlin; Tissot, Abbigail; Kollar, Linda M.; Hillard, Paula A.; Stone, Rachel; Kahn, Jessica A.
2007-01-01
Study Objectives To develop an educational protocol about HPV and Pap tests for adolescents, to evaluate the protocol for understandability and clarity, and to evaluate the protocol for its effectiveness in increasing knowledge about HPV. Design In phase 1, investigators and adolescents developed the protocol. In phase 2, adolescents evaluated the protocol qualitatively, investigators evaluated its effectiveness in increasing HPV knowledge in a sample of adolescents, and the protocol was revised. In phase 3, investigators evaluated the effectiveness of the revised protocol in an additional adolescent sample. Setting Urban, hospital-based teen health center. Participants A total of 252 adolescent girls and boys in the three study phases. Main Outcome Measures Pre- and post-protocol knowledge about HPV, measured using a 10- or 11-item scale. Results Scores on the HPV knowledge scale increased significantly (p<.0001) among adolescents who participated in phases 2 and 3 after they received the protocol. Initial differences in scores based on race, insurance type and condom use were not noted post-protocol. Conclusion The protocol significantly increased knowledge scores about HPV in this population, regardless of sociodemographic characteristics and risk behaviors. Effective, developmentally appropriate educational protocols about HPV and Pap tests are particularly important in clinical settings as cervical cancer screening guidelines evolve, HPV DNA testing is integrated into screening protocols, and HPV vaccines become available. In-depth, one-on-one education about HPV may also prevent adverse psychosocial responses and promote healthy sexual and Pap screening behaviors in adolescents with abnormal HPV or Pap test results. Synopsis The investigators developed an educational protocol about HPV and Pap tests and evaluated its effectiveness in increasing knowledge about HPV among adolescents. PMID:17868894
Dudda, Ravi; Muniyappa, Hanumanth Prasad; Puttaraju, Sahana; Lakshmi, M S
2017-07-01
Maternal active participation and their support are critical for the success of early hearing loss detection program. Erroneous maternal decisions may have large life long consequences on the infant's life. The mothers' knowledge and their attitudes towards infant hearing loss is the basis for their decisions. The present study was done to determine the mothers' knowledge and their attitude towards risk factors of infant hearing loss, its early identification and intervention and also awareness of effect of consanguinity on hearing loss. In this cross-sectional questionnaire survey study, a total of 100 mothers were interviewed using the questionnaire which consisted of three sections namely risk factors, early identification and early intervention of hearing loss. Chi-square test was used to establish relationship between consanguineous and non-consanguineous mother's responses to its effect on hearing loss. A p-value < 0.05 was considered as significant. Mothers' awareness was significantly high for visible causes (ear pain/discharge, head injury and slap to ear) of hearing loss. Positive attitude was seen for importance of screening programs and follow up testing. Moderate level of awareness was found on hazards of consanguinity and benefits of early identification. However, mothers were least aware of neonatal jaundice, NICU admission (>5 days), signs of late-onset and neural hearing loss, management of hearing loss, hearing aid fitting and therapy necessity, which might interfere in early detection and intervention of hearing loss. It is crucial to educate mothers on few risk factors and management of hearing loss to reduce its consequences.
Teeuw, Arianne H; Sieswerda-Hoogendoorn, Tessa; Sangers, Esmée J; Heymans, Hugo S A; van Rijn, Rick R
2016-01-01
This study examines the results of the implementation of a new screening protocol for child maltreatment (CM) at the Emergency Department (ED) of the Academic Medical Center in Amsterdam, The Netherlands. This protocol consists of adding a so called 'top-toe' inspection (TTI), an inspection of the fully undressed child, to the screening checklist for child maltreatment, the SPUTOVAMO. We collected data from all patients 0-18 years old directly after introduction (February 2010) and 9 months later. Outcome measures were: completion of the screening and reasons for non-adherence. Data were collected on age, gender, reason for visiting the ED (defined by International Classification of Disease, ICD), presence of a chronic illness, type of professional performing the TTI and admission during week or weekend days. In February 560 and in November 529 paediatric patients were admitted. In February the complete screening protocol was performed in 42% of all children, in November in 17%. A correlation between completion of the SPUTOVAMO and having a TTI performed was found. Older age and presence of a chronic illness influenced the chance of having both SPUTOVAMO and TTI performed negatively. The completion rate of SPUTOVAMO was influenced by ICD code. Completion of TTI was influenced by type of investigator. The best performing professional was the ED physician followed by the paediatrician followed by the ED nurse. The reasons for not performing a TTI were not documented. Refusal of the TTI by a patient or parent was reported three times. Implementation of this new screening protocol for CM was only mildly successful and declined in time. A negative correlation between older child age and having a chronic illness and completion of the screening was found. A practical recommendation resulting from this study could be that, if CM screening protocols prove to be effective in detecting CM, regular training sessions have to be held. Filling out the checklist is something that could be performed by ED nurses. Performing a TTI is perhaps easier for the ED physicians to make part of their daily routine. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sheikh Rashid, Marya; Leensen, Monique C J; de Laat, Jan A P M; Dreschler, Wouter A
2017-11-01
The "Occupational Earcheck" (OEC) is a Dutch online self-screening speech-in-noise test developed for the detection of occupational high-frequency hearing loss (HFHL). This study evaluates an optimised version of the test and determines the most appropriate masking noise. The original OEC was improved by homogenisation of the speech material, and shortening the test. A laboratory-based cross-sectional study was performed in which the optimised OEC in five alternative masking noise conditions was evaluated. The study was conducted on 18 normal-hearing (NH) adults, and 15 middle-aged listeners with HFHL. The OEC in a low-pass (LP) filtered stationary background noise (test version LP 3: with a cut-off frequency of 1.6 kHz, and a noise floor of -12 dB) was the most accurate version tested. The test showed a reasonable sensitivity (93%), and specificity (94%) and test reliability (intra-class correlation coefficient: 0.84, mean within-subject standard deviation: 1.5 dB SNR, slope of psychometric function: 13.1%/dB SNR). The improved OEC, with homogenous word material in a LP filtered noise, appears to be suitable for the discrimination between younger NH listeners and older listeners with HFHL. The appropriateness of the OEC for screening purposes in an occupational setting will be studied further.
High-Throughput Screening Assay for Embryoid Body Differentiation of Human Embryonic Stem Cells
Outten, Joel T.; Gadue, Paul; French, Deborah L.; Diamond, Scott L.
2012-01-01
Serum-free human pluripotent stem cell media offer the potential to develop reproducible clinically applicable differentiation strategies and protocols. The vast array of possible growth factor and cytokine combinations for media formulations makes differentiation protocol optimization both labor and cost-intensive. This unit describes a 96-well plate, 4-color flow cytometry-based screening assay to optimize pluripotent stem cell differentiation protocols. We provide conditions both to differentiate human embryonic stem cells (hESCs) to the three primary germ layers, ectoderm, endoderm, and mesoderm, and to utilize flow cytometry to distinguish between them. This assay exhibits low inter-well variability and can be utilized to efficiently screen a variety of media formulations, reducing cost, incubator space, and labor. Protocols can be adapted to a variety of differentiation stages and lineages. PMID:22415836
Serpanos, Yula C; Senzer, Deborah
2015-05-01
This study presents a piloted training model of experiential instruction in outer and middle ear (OE-ME) screening for graduate speech-language pathology students with peer teaching by doctor of audiology (AuD) students. Six individual experiential training sessions in screening otoscopy and tympanometry were conducted for 36 graduate-level speech-language pathology students led by a supervised AuD student. Postexperiential training, survey outcomes from 24 speech-language pathology students revealed a significant improvement (p = .01) in perceptions of attaining adequate knowledge and comfort in performing screening otoscopy (handheld and video otoscopy) and tympanometry. In a group of matched controls who did not receive experiential training in OE-ME screening (n = 24), ratings on the same learning outcomes survey in otoscopy and tympanometry were significantly poorer (p = .01) compared with students who did receive experiential training. A training model of experiential instruction for speech-language pathology students by AuD students improved learning outcomes, illustrating its promise in affecting clinical practices. The instructional model also meets the Council on Academic Accreditation in Audiology and Speech-Language Pathology (CAA; American Speech-Language-Hearing Association, 2008) and American Speech-Language-Hearing Association (2014) Certificate of Clinical Competence (ASHA CCC) standards for speech-language pathology in OE-ME screening and CAA (2008) and ASHA (2012) CCC standards in the supervisory process for audiology.
Gupta, Nishi; Chawla, Neeraj; Gupta, Digant; Dhawan, Nidhi; Janaki, Vidya R
2017-07-01
Chronic otitis media is a major contributor to acquired hearing loss in developing countries. Developing countries such as India, with huge populations and poor health infrastructures, have always felt the shortage of trained specialists who can provide quality care to meet the enormous demand for treatment of this disease. This pilot study assessed the feasibility of empowering trained health workers equipped with ENTraview, a store-and-forward telemedicine device that integrates a camera- enabled smart phone with an otoscope. This device allows the screening of otology patients within the community. Three months of extensive training was provided to five community health workers on primary ear and hearing care, including training on the use of the ENTraview device. Community otology screenings were conducted to triage otology patients and provide them with specialized ENT care at a tertiary hospital. In the initial 6 months of the project, 45 screening camps were organized, which screened 3,000 patients free of cost. Of these 3,000 screened patients, 54% (1,619) were referred for ENT consultation and 215 patients reported. Nearly 50% (103) of the 215 reporting patients required surgical intervention, and 29 patients underwent surgery. Reaching out to the community by remote screening of ear diseases by trained technicians with a telemedicine device seems to be an effective and cost-effective way to triage patients with otologic pathologies.
Eras, Zeynep; Konukseven, Ozlem; Aksoy, Hatice Tatar; Canpolat, Fuat Emre; Genç, Aydan; Sakrucu, Evrim Durgut; Develioğlu, Omer; Dilmen, Ugur
2014-06-01
The aim of this study was to determine the postnatal risk factors associated with hearing loss as well as the prevalence of hearing loss among high-risk preterm infants in newborn hearing screening (NHS). We performed a retrospective study of high-risk preterm infants born with a gestational age ≤32 weeks and/or a birth weight ≤1,500 g. A NHS procedure was performed by automated auditory brainstem response (AABR) and automated evoked otoacoustic emission (TEOAE). Infants who failed TEOAE or AABR or both tests were referred to a tertiary audiology center for diagnosis confirmation and management. Postnatal risk factors associated with hearing loss were evaluated and compared for preterm infants with and without hearing loss. 1,360 high-risk preterm infants were assessed. Permanent hearing loss was found in 19 (1.4%) infants. Multivariate analysis revealed that proven sepsis (p = 0.019), mechanical ventilation ≥5 days (p = 0.024), loop diuretics (p = 0.001), patent ductus arteriosus ligation (p = 0.018) and operation for retinopathy of prematurity (ROP) (p = 0.034) were significant related factors for the hearing loss. This study showed a low prevalence of hearing loss and an association between operation for ROP and hearing loss in preterm infants, which has not been defined previously. Our results suggest that every neonatal intensive care unit should determine their own risk factors and take precautions to prevent hearing loss for these high-risk preterm infants.
Rapport, Frances L; Boisvert, Isabelle; McMahon, Catherine M; Hutchings, Hayley A
2017-01-01
Introduction In the UK, it is estimated that a disabling hearing loss (HL) affects 1 in 6 people. HL has functional, economic and social-emotional consequences for affected individuals. Intervention for HL focuses on improving access to the auditory signal using hearing aids or cochlear implants. However, even if sounds are audible and speech is understood, individuals with HL often report increased effort when listening. Listening effort (LE) may be measured using self-reported measures such as patient-reported outcome measures (PROMs). PROMs are validated questionnaires completed by patients to measure their perceptions of their own functional status and well-being. When selecting a PROM for use in research or clinical practice, it is necessary to appraise the evidence of a PROM’s acceptability to patients, validity, responsiveness and reliability. Methods and analysis A systematic review of studies evaluating the measurement properties of PROMs available to measure LE in HL will be undertaken. MEDLINE, EMBASE, CINAHL, PsychINFO and Web of Science will be searched electronically. Reference lists of included studies, key journals and the grey literature will be hand-searched to identify further studies for inclusion. Two reviewers will independently complete title, abstract and full-text screening to determine study eligibility. Data on the characteristics of each study and each PROM will be extracted. Methodological quality of the included studies will be appraised using the COnsensus-based Standards for the selection of health Measurement INstruments, the quality of included PROMs appraised and the credibility of the evidence assessed. A narrative synthesis will summarise extracted data. Ethics and dissemination Ethical permission is not required, as this study uses data from published research. Dissemination will be through publication in peer-reviewed journals, conference presentations and the lead author’s doctoral dissertation. Findings may inform the selection of PROMs used to measure LE in HL. PMID:28592576
de Kleijn, Jasper L; van Kalmthout, Ludwike W M; van der Vossen, Martijn J B; Vonck, Bernard M D; Topsakal, Vedat; Bruijnzeel, Hanneke
2018-05-24
Although current guidelines recommend cochlear implantation only for children with profound hearing impairment (HI) (>90 decibel [dB] hearing level [HL]), studies show that children with severe hearing impairment (>70-90 dB HL) could also benefit from cochlear implantation. To perform a systematic review to identify audiologic thresholds (in dB HL) that could serve as an audiologic candidacy criterion for pediatric cochlear implantation using 4 domains of speech and language development as independent outcome measures (speech production, speech perception, receptive language, and auditory performance). PubMed and Embase databases were searched up to June 28, 2017, to identify studies comparing speech and language development between children who were profoundly deaf using cochlear implants and children with severe hearing loss using hearing aids, because no studies are available directly comparing children with severe HI in both groups. If cochlear implant users with profound HI score better on speech and language tests than those with severe HI who use hearing aids, this outcome could support adjusting cochlear implantation candidacy criteria to lower audiologic thresholds. Literature search, screening, and article selection were performed using a predefined strategy. Article screening was executed independently by 4 authors in 2 pairs; consensus on article inclusion was reached by discussion between these 4 authors. This study is reported according to the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. Title and abstract screening of 2822 articles resulted in selection of 130 articles for full-text review. Twenty-one studies were selected for critical appraisal, resulting in selection of 10 articles for data extraction. Two studies formulated audiologic thresholds (in dB HLs) at which children could qualify for cochlear implantation: (1) at 4-frequency pure-tone average (PTA) thresholds of 80 dB HL or greater based on speech perception and auditory performance subtests and (2) at PTA thresholds of 88 and 96 dB HL based on a speech perception subtest. In 8 of the 18 outcome measures, children with profound HI using cochlear implants performed similarly to children with severe HI using hearing aids. Better performance of cochlear implant users was shown with a picture-naming test and a speech perception in noise test. Owing to large heterogeneity in study population and selected tests, it was not possible to conduct a meta-analysis. Studies indicate that lower audiologic thresholds (≥80 dB HL) than are advised in current national and manufacturer guidelines would be appropriate as audiologic candidacy criteria for pediatric cochlear implantation.
Results obtained with a low cost software-based audiometer for hearing screening.
Ferrari, Deborah Viviane; Lopez, Esteban Alejandro; Lopes, Andrea Cintra; Aiello, Camila Piccini; Jokura, Pricila Reis
2013-07-01
The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. To evaluate the TS audiometer for conducting audiometric screening. A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.
It Is Time to Rethink Central Auditory Processing Disorder Protocols for School-Aged Children.
DeBonis, David A
2015-06-01
The purpose of this article is to review the literature that pertains to ongoing concerns regarding the central auditory processing construct among school-aged children and to assess whether the degree of uncertainty surrounding central auditory processing disorder (CAPD) warrants a change in current protocols. Methodology on this topic included a review of relevant and recent literature through electronic search tools (e.g., ComDisDome, PsycINFO, Medline, and Cochrane databases); published texts; as well as published articles from the Journal of the American Academy of Audiology; the American Journal of Audiology; the Journal of Speech, Language, and Hearing Research; and Language, Speech, and Hearing Services in Schools. This review revealed strong support for the following: (a) Current testing of CAPD is highly influenced by nonauditory factors, including memory, attention, language, and executive function; (b) the lack of agreement regarding the performance criteria for diagnosis is concerning; (c) the contribution of auditory processing abilities to language, reading, and academic and listening abilities, as assessed by current measures, is not significant; and (d) the effectiveness of auditory interventions for improving communication abilities has not been established. Routine use of CAPD test protocols cannot be supported, and strong consideration should be given to redirecting focus on assessing overall listening abilities. Also, intervention needs to be contextualized and functional. A suggested protocol is provided for consideration. All of these issues warrant ongoing research.
Hearing Impairment Among Children Referred to a Public Audiology Clinic in Gaborone, Botswana.
Banda, Francis M; Powis, Kathleen M; Mokoka, Agnes B; Mmapetla, Moalosi; Westmoreland, Katherine D; David, Thuso; Steenhoff, Andrew P
2018-01-01
Objective . To describe and quantify hearing impairment among children referred to the audiology clinic in Princess Marina Hospital, a public referral hospital in Botswana. Methods . In a retrospective case series, we reviewed medical records of children aged 10 years and younger whose hearing was assessed between January 2006 and December 2015 at the audiology clinic of Princess Marina Hospital in Gaborone, Botswana. Results . Of 622 children, 50% were male, and median age was 6.7 years (interquartile range = 5.0-8.3). Hearing impairment was diagnosed in 32% of clinic attendees, comprising sensorineural (23%), conductive (25%), and mixed (11%) hearing loss, while 41% of children with diagnosed hearing impairment did not have a classification type. Hearing impairment was mild in 22.9%, moderate in 22.4%, severe in 19.4%, profound in 16.9%, and of undocumented severity in 18.4%. Children younger than 5 years were 2.7 times (95% confidence interval = 1.29-5.49; P = .008) more likely to be diagnosed with sensorineural hearing impairment compared with those older than 5 years. By contrast, children older than 5 years were 9.6 times (95% confidence interval = 2.22-41.0; P = .002) more likely to be diagnosed with conductive hearing loss compared with those under 5 years. Conclusion . Hearing impairment was common among children referred to this audiology clinic in Botswana. Of those with hearing impairment, more than a third had moderate or severe deficits, suggesting that referrals for hearing assessments are not occurring early enough. Hearing awareness programs individually tailored to parents, educators, and health care workers are needed. Neonatal and school hearing screening programs would also be beneficial.
Beliaev, Andrei M; Barber, P Alan; Marshall, Roger J; Civil, Ian
2014-06-01
Blunt cerebrovascular injury (BCVI) occurs in 0.2-2.7% of blunt trauma patients and has up to 30% mortality. Conventional screening does not recognize up to 20% of BCVI patients. To improve diagnosis of BCVI, both an expanded battery of screening criteria and a multi-detector computed tomography angiography (CTA) have been suggested. The aim of this study is to investigate whether the use of CTA restricted to the Denver protocol screen-positive patients would reduce the unnecessary use of CTA as a pre-emptive screening tool. This is a registry-based study of blunt trauma patients admitted to Auckland City Hospital from 1998 to 2012. The diagnosis of BCVI was confirmed or excluded with CTA, magnetic resonance angiography and, if these imaging were non-conclusive, four-vessel digital subtraction angiography. Thirty (61%) BCVI and 19 (39%) non-BCVI patients met eligibility criteria. The Denver protocol applied to our cohort of patients had a sensitivity of 97% (95% confidence interval (CI): 83-100%) and a specificity of 42% (95% CI: 20-67%). With a prevalence of BCVI in blunt trauma patients of 0.2% and 2.7%, post-test odds of a screen-positive test were 0.03 (95% CI: 0.002-0.005) and 0.046 (95% CI: 0.314-0.068), respectively. Application of the CTA to the Denver protocol screen-positive trauma patients can decrease the use of CTA as a pre-emptive screening tool by 95-97% and reduces its hazards. © 2013 Royal Australasian College of Surgeons.
Aller, E; Jaijo, T; Oltra, S; Alió, J; Galán, F; Nájera, C; Beneyto, M; Millán, J M
2004-12-01
Usher syndrome type III is an autosomal recessive disorder clinically characterized by the association of retinitis pigmentosa (RP), variable presence of vestibular dysfunction and progressive hearing loss, being the progression of the hearing impairment the critical parameter classically used to distinguish this form from Usher syndrome type I and Usher syndrome type II. Usher syndrome type III clinical subtype is the rarest form of Usher syndrome in Spain, accounting only for 6% of all Usher syndrome Spanish cases. The gene responsible for Usher syndrome type III is named clarin-1 and it is thought to be involved in hair cell and photoreceptor cell synapses. Here, we report a screening for mutations in clarin-1 gene among our series of Usher syndrome Spanish patients. Clarin-1 has been found to be responsible for the disease in only two families: the first one is a previously reported family homozygous for Y63X mutation and the second one, described here, is homozygous for C40G. This accounts for 1.7% of Usher syndrome Spanish families. It is noticeable that, whereas C40G family is clinically compatible with Usher syndrome type III due to the progression of the hearing loss, Y63X family could be diagnosed as Usher syndrome type I because the hearing impairment is profound and stable. Thus, we consider that the progression of hearing loss is not the definitive key parameter to distinguish Usher syndrome type III from Usher syndrome type I and Usher syndrome type II.
Bastanza, G; Gallus, R; De Carlini, M; Picciotti, P M; Muzzi, E; Ciciriello, E; Orzan, E; Conti, G
2016-02-01
Diagnosis of child permanent hearing impairment (PHI) can be made with extreme timeliness compared to the past thanks to improvements in PHI identification through newborn hearing screening programmes. It now becomes essential to provide an effective amplification as quickly as possible in order to restore auditory function and favour speech and language development. The early fitting of hearing aids and possible later cochlear implantation indeed prompts the development of central auditory pathways, connections with secondary sensory brain areas, as well as with motor and articulatory cortex. The aim of this paper is to report the results of a strategic analysis that involves identification of strengths, weaknesses, opportunities and threats regarding the process of achieving early amplification in all cases of significant childhood PHI. The analysis is focused on the Italian situation and is part of the Italian Ministry of Health project CCM 2013 "Preventing Communication Disorders: a Regional Program for Early Identification, Intervention and Care of Hearing Impaired Children". © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale.
Genetic Landscape of Auditory Dysfunction.
Bowl, Michael R; Brown, S D M
2018-05-02
Over the past 25 years, human and mouse genetics research together has identified several hundred genes essential for mammalian hearing, leading to a greater understanding of the molecular mechanisms underlying auditory function. However, from the number of still as yet uncloned human deafness loci and the findings of large-scale mouse mutant screens, it is clear we are still far from identifying all of the genes critical for auditory function. In particular, while we have made great progress in understanding the genetic bases of congenital and early-onset hearing loss, we have only just begun to elaborate upon the genetic landscape of age-related hearing loss. With an aging population and a growing literature suggesting links between age-related hearing loss and neuropsychiatric conditions, such as dementia and depression, understanding the genetics and subsequently the molecular mechanisms underlying this very prevalent condition is of paramount importance. Increased knowledge of genes and molecular pathways required for hearing will ultimately provide the foundation upon which novel therapeutic approaches can be built. Here we discuss the current status of deafness genetics research and the ongoing efforts being undertaken for discovery of novel genes essential for hearing.
78 FR 39017 - Investigative Hearing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... emergency response operations, roles of the response teams, evacuations and communications, incident response protocols, hazmat training, oversight of Paulsboro emergency preparedness, roles of local, state... of 2 locomotives and 82 cars, derailed 7 cars near milepost 13.7 on the Conrail Penn's Grove...
Are hearing losses among young Maori different to those found in the young NZ European population?
Digby, Janet E; Purdy, Suzanne C; Kelly, Andrea S; Welch, David; Thorne, Peter R
2014-07-18
This study was undertaken to determine if young Maori have more permanent bilateral hearing loss, or less severe and profound hearing loss than New Zealand (NZ) Europeans. Data include hearing-impaired children from birth to 19 years of age from the New Zealand Deafness Notification Database (DND) and covering the periods 1982-2005 and 2009-2013. These were retrospectively analysed, as was information on children and young people with cochlear implants. Young Maori are more likely to be diagnosed with permanent hearing loss greater than 26 dB HL, averaged across speech frequencies, with 39-43% of hearing loss notifications listed as Maori. Maori have a lower prevalence of severe/profound losses (n=1571, chi squared=22.08, p=0.01) but significantly more bilateral losses than their NZ European peers (n=595, Chi-squared=9.05, p=0.01). The difference in severity profile is supported by cochlear implant data showing Maori are less likely to receive a cochlear implant. There are significant differences in the proportion of bilateral (compared to unilateral) losses and in the rates and severity profile of hearing loss among young Maori when compared with their NZ European peers. This has implications for screening and other hearing services in NZ.
Gardner-Berry, Kirsty; Chang, Hsiuwen; Ching, Teresa Y. C.; Hou, Sanna
2016-01-01
With the introduction of newborn hearing screening, infants are being diagnosed with hearing loss during the first few months of life. For infants with a sensory/neural hearing loss (SNHL), the audiogram can be estimated objectively using auditory brainstem response (ABR) testing and hearing aids prescribed accordingly. However, for infants with auditory neuropathy spectrum disorder (ANSD) due to the abnormal/absent ABR waveforms, alternative measures of auditory function are needed to assess the need for amplification and evaluate whether aided benefit has been achieved. Cortical auditory evoked potentials (CAEPs) are used to assess aided benefit in infants with hearing loss; however, there is insufficient information regarding the relationship between stimulus audibility and CAEP detection rates. It is also not clear whether CAEP detection rates differ between infants with SNHL and infants with ANSD. This study involved retrospective collection of CAEP, hearing threshold, and hearing aid gain data to investigate the relationship between stimulus audibility and CAEP detection rates. The results demonstrate that increases in stimulus audibility result in an increase in detection rate. For the same range of sensation levels, there was no difference in the detection rates between infants with SNHL and ANSD. PMID:27587922
Functional genomics platform for pooled screening and mammalian genetic interaction maps
Kampmann, Martin; Bassik, Michael C.; Weissman, Jonathan S.
2014-01-01
Systematic genetic interaction maps in microorganisms are powerful tools for identifying functional relationships between genes and defining the function of uncharacterized genes. We have recently implemented this strategy in mammalian cells as a two-stage approach. First, genes of interest are robustly identified in a pooled genome-wide screen using complex shRNA libraries. Second, phenotypes for all pairwise combinations of hit genes are measured in a double-shRNA screen and used to construct a genetic interaction map. Our protocol allows for rapid pooled screening under various conditions without a requirement for robotics, in contrast to arrayed approaches. Each stage of the protocol can be implemented in ~2 weeks, with additional time for analysis and generation of reagents. We discuss considerations for screen design, and present complete experimental procedures as well as a full computational analysis suite for identification of hits in pooled screens and generation of genetic interaction maps. While the protocols outlined here were developed for our original shRNA-based approach, they can be applied more generally, including to CRISPR-based approaches. PMID:24992097
Asymmetric Hearing During Development: The Aural Preference Syndrome and Treatment Options.
Gordon, Karen; Henkin, Yael; Kral, Andrej
2015-07-01
Deafness affects ∼2 in 1000 children and is one of the most common congenital impairments. Permanent hearing loss can be treated by fitting hearing aids. More severe to profound deafness is an indication for cochlear implantation. Although newborn hearing screening programs have increased the identification of asymmetric hearing loss, parents and caregivers of children with single-sided deafness are often hesitant to pursue therapy for the deaf ear. Delayed intervention has consequences for recovery of hearing. It has long been reported that asymmetric hearing loss/single-sided deafness compromises speech and language development and educational outcomes in children. Recent studies in animal models of deafness and in children consistently show evidence of an "aural preference syndrome" in which single-sided deafness in early childhood reorganizes the developing auditory pathways toward the hearing ear, with weaker central representation of the deaf ear. Delayed therapy consequently compromises benefit for the deaf ear, with slow rates of improvement measured over time. Therefore, asymmetric hearing needs early identification and intervention. Providing early effective stimulation in both ears through appropriate fitting of auditory prostheses, including hearing aids and cochlear implants, within a sensitive period in development has a cardinal role for securing the function of the impaired ear and for restoring binaural/spatial hearing. The impacts of asymmetric hearing loss on the developing auditory system and on spoken language development have often been underestimated. Thus, the traditional minimalist approach to clinical management aimed at 1 functional ear should be modified on the basis of current evidence. Copyright © 2015 by the American Academy of Pediatrics.
Screening for Spiritual Struggle in an Adolescent Transgender Clinic: Feasibility and Acceptability.
Grossoehme, Daniel H; Teeters, Alexis; Jelinek, Sue; Dimitriou, Sophia M; Conard, Lee Ann E
2016-01-01
Spiritual struggles are associated with poorer health outcomes, including depression, which has higher prevalence among transgender individuals than the general population. This study's objective was to improve the quality of care in an outpatient transgender clinic by screening patients and caregivers for spiritual struggle and future intervention. The quality improvement questions addressed were whether screening for spiritual struggle was feasible and acceptable; and whether the sensitivity and specificity of the Rush Protocol were acceptable. Revision of the screening was based on cognitive interviews with the 115 adolescents and caregivers who were screened. Prevalence of spiritual struggle was 38-47%. Compared to the Negative R-COPE, the Rush Protocol screener had sensitivities of 44-80% and specificities of 60-74%. The Rush Protocol was acceptable to adolescents seen in a transgender clinic, caregivers, and clinic staff; was feasible to deliver during outpatient clinic visits, and offers a straightforward means of identifying transgender persons and caregivers experiencing spiritual struggle.
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. House Committee on Energy and Commerce.
These hearings examine the problem of lead poisoning in children and explore the consequences of the transfer of funds for lead-screening efforts to the maternal child health block grant. Lead toxicity is described as probably the most significant and pervasive environmental illness in the United States. Testimony asserts that the effect of the…
A Public-Use, Full-Screen Interface for SPIRES Databases.
ERIC Educational Resources Information Center
Kriz, Harry M.
This paper describes the techniques for implementing a full-screen, custom SPIRES interface for a public-use library database. The database-independent protocol that controls the system is described in detail. Source code for an entire working application using this interface is included. The protocol, with less than 170 lines of procedural code,…
CDK2 inhibitors as candidate therapeutics for cisplatin- and noise-induced hearing loss.
Teitz, Tal; Fang, Jie; Goktug, Asli N; Bonga, Justine D; Diao, Shiyong; Hazlitt, Robert A; Iconaru, Luigi; Morfouace, Marie; Currier, Duane; Zhou, Yinmei; Umans, Robyn A; Taylor, Michael R; Cheng, Cheng; Min, Jaeki; Freeman, Burgess; Peng, Junmin; Roussel, Martine F; Kriwacki, Richard; Guy, R Kiplin; Chen, Taosheng; Zuo, Jian
2018-04-02
Hearing loss caused by aging, noise, cisplatin toxicity, or other insults affects 360 million people worldwide, but there are no Food and Drug Administration-approved drugs to prevent or treat it. We screened 4,385 small molecules in a cochlear cell line and identified 10 compounds that protected against cisplatin toxicity in mouse cochlear explants. Among them, kenpaullone, an inhibitor of multiple kinases, including cyclin-dependent kinase 2 (CDK2), protected zebrafish lateral-line neuromasts from cisplatin toxicity and, when delivered locally, protected adult mice and rats against cisplatin- and noise-induced hearing loss. CDK2-deficient mice displayed enhanced resistance to cisplatin toxicity in cochlear explants and to cisplatin- and noise-induced hearing loss in vivo. Mechanistically, we showed that kenpaullone directly inhibits CDK2 kinase activity and reduces cisplatin-induced mitochondrial production of reactive oxygen species, thereby enhancing cell survival. Our experiments have revealed the proapoptotic function of CDK2 in postmitotic cochlear cells and have identified promising therapeutics for preventing hearing loss. © 2018 Teitz et al.
CDK2 inhibitors as candidate therapeutics for cisplatin- and noise-induced hearing loss
Teitz, Tal; Fang, Jie; Goktug, Asli N.; Bonga, Justine D.; Diao, Shiyong; Iconaru, Luigi; Morfouace, Marie; Currier, Duane; Zhou, Yinmei; Umans, Robyn A.; Taylor, Michael R.; Cheng, Cheng; Peng, Junmin; Roussel, Martine F.; Kriwacki, Richard; Guy, R. Kiplin; Chen, Taosheng
2018-01-01
Hearing loss caused by aging, noise, cisplatin toxicity, or other insults affects 360 million people worldwide, but there are no Food and Drug Administration–approved drugs to prevent or treat it. We screened 4,385 small molecules in a cochlear cell line and identified 10 compounds that protected against cisplatin toxicity in mouse cochlear explants. Among them, kenpaullone, an inhibitor of multiple kinases, including cyclin-dependent kinase 2 (CDK2), protected zebrafish lateral-line neuromasts from cisplatin toxicity and, when delivered locally, protected adult mice and rats against cisplatin- and noise-induced hearing loss. CDK2-deficient mice displayed enhanced resistance to cisplatin toxicity in cochlear explants and to cisplatin- and noise-induced hearing loss in vivo. Mechanistically, we showed that kenpaullone directly inhibits CDK2 kinase activity and reduces cisplatin-induced mitochondrial production of reactive oxygen species, thereby enhancing cell survival. Our experiments have revealed the proapoptotic function of CDK2 in postmitotic cochlear cells and have identified promising therapeutics for preventing hearing loss. PMID:29514916
The Effectiveness of a Vocational Enablement Protocol for Employees With Hearing Difficulties
Gussenhoven, Arjenne H. M.; Anema, Johannes R.; Witte, Birgit I.; Goverts, S. Theo
2017-01-01
The aim of this study was to evaluate the effectiveness of a vocational enablement protocol (VEP) on need for recovery (NFR) after work as compared with usual care for employees with hearing difficulties. In a randomized controlled trial design, 136 employees with hearing impairment were randomly assigned to either the VEP or the control group. VEP is a multidisciplinary program integrating audiological and occupational care for individuals experiencing difficulties in the workplace due to hearing loss. The primary outcome measure was NFR. Secondary outcome measures were communication strategy subscales (e.g., self-acceptance and maladaptive behavior), distress, and self-efficacy. Data were collected using questionnaires at baseline and at 3, 6, 9, and 12 months follow-up. No significant difference over the complete follow-up period was found between the intervention and control group for NFR. However, we observed a significant difference for one of the secondary outcomes after 12 months. “Self-acceptance” increased significantly in the VEP group, compared with the controls. The mean difference between the two groups was small, being only 0.24 (95% CI [0.04, 0.44]) on a scale of 1 to 5. The results do not support the use of VEP if the aim is to reduce NFR after work at 12 months follow-up. It may be that NFR does not adequately capture what is covered in the VEP. Although marginal, the effect on self-acceptance was significant. This is encouraging given that positive effects on self-acceptance have rarely been shown for audiological rehabilitation programs. Suggestions for further improvement of the VEP are discussed. PMID:29298599
Hearing loss in children with growth hormone deficiency.
Muus, John S; Weir, Forest W; Kreicher, Kathryn L; Bowlby, Deborah A; Discolo, Christopher M; Meyer, Ted A
2017-09-01
Although insulin-like growth factor 1 (IGF-1) has been shown to be important for inner-ear development in animal models, little is known about the otologic and audiologic findings of children with growth hormone deficiency (GHD). The goal of this study is to evaluate the prevalence, type, and severity of hearing impairment in children with GHD. Audiologic, otologic, and demographic data were recorded for children with a diagnosis of GHD in the AudGen database. Data for each patient were selected based on the first encounter with available complete audiometric data or the first encounter with a type of hearing loss documented. The patients were then stratified by type and severity of hearing loss, and otologic issues were documented. A separate cohort comprised of children with GHD without hearing loss was compared as a control. 209 children with GHD met inclusion criteria. 173 (83%) of these patients had hearing loss. 79% of losses were bilateral and 21% were unilateral (309 total ears with hearing loss). 293 of the 309 ears with hearing loss had audiograms with ear-specific thresholds; 47 had conductive, 24 had sensorineural, 65 had mixed and 157 had undefined hearing loss with incomplete audiograms. Pure-tone averages (PTA) were higher among patients with mixed hearing loss compared to patients with all other loss types. Hearing loss is prevalent in children with GHD with a predisposition to be bilateral. These findings suggest the need for increased awareness and routine hearing screening for patients with GHD. Further studies may elucidate the etiology of the hearing impairment in children with GHD to better aid pediatricians, endocrinologists, otolaryngologists and audiologists when assessing and managing these children. Copyright © 2017 Elsevier B.V. All rights reserved.
Prevalence of Hearing Loss in Teachers of Singing and Voice Students.
Isaac, Mitchell J; McBroom, Deanna H; Nguyen, Shaun A; Halstead, Lucinda A
2017-05-01
Singers and voice teachers are exposed to a range of noise levels during a normal working day. This study aimed to assess the hearing thresholds in a large sample of generally healthy professional voice teachers and voice students to determine the prevalence of hearing loss in this population. A cross-sectional study was carried out. Voice teachers and vocal students had the option to volunteer for a hearing screening of six standard frequencies in a quiet room with the Shoebox audiometer (Clearwater Clinical Limited) and to fill out a brief survey. Data were analyzed for the prevalence and severity of hearing loss in teachers and students based on several parameters assessed in the surveys. All data were analyzed using Microsoft Excel (Microsoft Corp.) and SPSS Statistics Software (IBM Corp.). A total of 158 participants were included: 58 self-identified as voice teachers, 106 as voice students, and 6 as both. The 6 participants who identified as both, were included in both categories for statistical purposes. Of the 158 participants, 36 had some level of hearing loss: 51.7% of voice teachers had hearing loss, and 7.5% of voice students had hearing loss. Several parameters of noise exposure were found to positively correlate with hearing loss and tinnitus (P < 0.05). Years as a voice teacher and age were both predictors of hearing loss (P < 0.05). Hearing loss in a cohort of voice teachers appears to be more prevalent and severe than previously thought. There is a significant association between years teaching and hearing loss. Raising awareness in this population may prompt teachers and students to adopt strategies to protect their hearing. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Dudda, Ravi; Muniyappa, Hanumanth Prasad; Lakshmi, M.S
2017-01-01
Introduction Maternal active participation and their support are critical for the success of early hearing loss detection program. Erroneous maternal decisions may have large life long consequences on the infant’s life. The mothers’ knowledge and their attitudes towards infant hearing loss is the basis for their decisions. Aim The present study was done to determine the mothers’ knowledge and their attitude towards risk factors of infant hearing loss, its early identification and intervention and also awareness of effect of consanguinity on hearing loss. Materials and Methods In this cross-sectional questionnaire survey study, a total of 100 mothers were interviewed using the questionnaire which consisted of three sections namely risk factors, early identification and early intervention of hearing loss. Chi-square test was used to establish relationship between consanguineous and non-consanguineous mother’s responses to its effect on hearing loss. A p-value < 0.05 was considered as significant. Results Mothers’ awareness was significantly high for visible causes (ear pain/discharge, head injury and slap to ear) of hearing loss. Positive attitude was seen for importance of screening programs and follow up testing. Moderate level of awareness was found on hazards of consanguinity and benefits of early identification. However, mothers were least aware of neonatal jaundice, NICU admission (>5 days), signs of late-onset and neural hearing loss, management of hearing loss, hearing aid fitting and therapy necessity, which might interfere in early detection and intervention of hearing loss. Conclusion It is crucial to educate mothers on few risk factors and management of hearing loss to reduce its consequences. PMID:28892940
Feldmann, H
2001-12-01
Investigating cases of noise induced hearing loss the expert is often confronted with the situation that the hearing loss is progressive although the noise exposure has been reduced to almost non-damaging levels. Other causes such as age, hereditary deafness, head injuries, blasts, internal diseases can be excluded. Hearing aids as sources of damaging noise? By consulting the protocol of the hearing-aid acoustician and by own examinations the expert should obtain the following data: loudness level that yields best discrimination score of speech; level of discomfort for tones and speech, discrimination score that is achieved under free field condition with a speech level of 65 dB, using the hearing aids. Furthermore he should explore the circumstances under which the hearing aids are used: how many hours per day, at what occasions etc.? It is likely that in using the hearing aids they are adjusted to emit an intensity level identical to the one yielding the optimal discrimination score. If this e. g. is 100 dB and the hearing aids are used for 2 hours per day this would be equivalent to an exposure to industrial noise of 94 dB (A) for 8 hours daily without ear protection. Among all individuals working under industrial noise exposure today only about 1 - 2 % having unusually vulnerable inner ears will suffer a noise induced hearing loss. On the other hand workers in industrial noise are accustomed to loud noise levels, usually have a raised threshold of discomfort and therefore are likely to adjust their hearing aids to such high intensities. The expert will have to decide whether in an individual case the industrial noise exposure or the use of the hearing aids is the dominant risk for further damage. The consequences in respect to the regulations of the workers' health insurance are discussed.
Adherence to, and outcomes of, a galactomannan screening protocol in high-risk hematology patients.
Harricharan, S; Biederman, K; Bombassaro, A M; Lazo-Langner, A; Elsayed, S; Fulford, A; Delport, J A; Xenocostas, A
2018-04-01
A twice-weekly galactomannan (gm) screening protocol was implemented in high-risk hematology inpatients. Study objectives were to determine adherence to the protocol, use of selected resources, and patient outcomes. This retrospective cohort study compared outcomes of interest before and after implementation of gm screening. Adults undergoing matched related allogeneic hematopoietic stem-cell transplantation or induction chemotherapy for acute leukemia were eligible. Patients could be enrolled more than once and were evaluated as episodes. Adherence to the gm protocol was assessed in post-implementation episodes. Use of broad-spectrum antifungals (bsafs), consultations (infectious diseases, respirology), and diagnostic procedures (computed tomography imaging, bronchoalveolar lavage) were compared between phases, as were the patient outcomes of all-cause mortality and clinical success (alive and not taking a bsaf). Of 182 episodes consecutively screened, 70 per phase were enrolled. Clinical characteristics and duration of assessment were similar for the phases. Full or partial adherence to the protocol was observed in 61 post-implementation episodes (87%), with full adherence in 40 episodes (57%). More episodes in the pre-implementation phase than in the post-implementation phase involved receipt of bsafs, consultations, and diagnostics (27% vs. 7%, p = 0.02; 46% vs. 26%, p = 0.014; and 46% vs. 31%, p = 0.083 respectively). Although mortality was similar in the two phases, clinical success at the final assessment was observed in fewer pre-implementation than post-implementation episodes (79% vs. 98%, p < 0.001). Implementation of a gm screening protocol was feasible and associated with significantly fewer episodes involving receipt of bsafs and consultations, and with significantly more episodes showing clinical success.
Tinnitus in normally hearing patients: clinical aspects and repercussions.
Sanchez, Tanit Ganz; Medeiros, Italo Roberto Torres de; Levy, Cristiane Passos Dias; Ramalho, Jeanne da Rosa Oiticica; Bento, Ricardo Ferreira
2005-01-01
Patients with tinnitus and normal hearing constitute an important group, given that findings do not suffer influence of the hearing loss. However, this group is rarely studied, so we do not know whether its clinical characteristics and interference in daily life are the same of those of the patients with tinnitus and hearing loss. To compare tinnitus characteristics and interference in daily life among patients with and without hearing loss. Historic cohort. Among 744 tinnitus patients seen at a Tinnitus Clinic, 55 with normal audiometry were retrospectively evaluated. The control group consisted of 198 patients with tinnitus and hearing loss, following the same protocol. We analyzed the patients' data as well as the tinnitus characteristics and interference in daily life. The mean age of the studied group (43.1 +/- 13.4 years) was significantly lower than that of the control group (49.9 +/- 14.5 years). In both groups, tinnitus was predominant in women, bilateral, single tone and constant, but there were no differences between both groups. The interference in concentration and emotional status (25.5% and 36.4%) was significantly lower in the studied group than that of the control group (46% and 61.6%), but it did not happen in regard to interference over sleep and social life. Patients with tinnitus and normal hearing showed similar characteristics when compared to those with hearing loss. However, the age of the patients and the interference over concentration and emotional status were significantly lower in this group.
Hildebrand, Michael S; Morín, Matías; Meyer, Nicole C; Mayo, Fernando; Modamio-Hoybjor, Silvia; Mencía, Angeles; Olavarrieta, Leticia; Morales-Angulo, Carmelo; Nishimura, Carla J; Workman, Heather; DeLuca, Adam P; del Castillo, Ignacio; Taylor, Kyle R; Tompkins, Bruce; Goodman, Corey W; Schrauwen, Isabelle; Wesemael, Maarten Van; Lachlan, K; Shearer, A Eliot; Braun, Terry A; Huygen, Patrick L M; Kremer, Hannie; Van Camp, Guy; Moreno, Felipe; Casavant, Thomas L; Smith, Richard J H; Moreno-Pelayo, Miguel A
2011-07-01
The prevalence of DFNA8/DFNA12 (DFNA8/12), a type of autosomal dominant nonsyndromic hearing loss (ADNSHL), is unknown as comprehensive population-based genetic screening has not been conducted. We therefore completed unbiased screening for TECTA mutations in a Spanish cohort of 372 probands from ADNSHL families. Three additional families (Spanish, Belgian, and English) known to be linked to DFNA8/12 were also included in the screening. In an additional cohort of 835 American ADNSHL families, we preselected 73 probands for TECTA screening based on audiometric data. In aggregate, we identified 23 TECTA mutations in this process. Remarkably, 20 of these mutations are novel, more than doubling the number of reported TECTA ADNSHL mutations from 13 to 33. Mutations lie in all domains of the α-tectorin protein, including those for the first time identified in the entactin domain, as well as the vWFD1, vWFD2, and vWFD3 repeats, and the D1-D2 and TIL2 connectors. Although the majority are private mutations, four of them-p.Cys1036Tyr, p.Cys1837Gly, p.Thr1866Met, and p.Arg1890Cys-were observed in more than one unrelated family. For two of these mutations founder effects were also confirmed. Our data validate previously observed genotype-phenotype correlations in DFNA8/12 and introduce new correlations. Specifically, mutations in the N-terminal region of α-tectorin (entactin domain, vWFD1, and vWFD2) lead to mid-frequency NSHL, a phenotype previously associated only with mutations in the ZP domain. Collectively, our results indicate that DFNA8/12 hearing loss is a frequent type of ADNSHL. © 2011 Wiley-Liss, Inc.
[Objective functional compensation in NHIL: INAIL prosthesic protocol in Lombardy, 2007-2010].
Calcinoni, O; Polo, L
2011-01-01
Even if NHIL gives already right to economic compensation, our Insurance aimed to real functional compensation, to reduce handicap in everyday life. Together with Professor Giordano, Audioprosthesists' Association and Manufacturers' representatives, INAIL Medical Superintendence started in 2003 a study on this problem, involving some of his forensic physician and ENT staff; in 2007-2009 INAIL issued directives innovating and planning the rules in prosthesis provision, not only acoustical ones. In 2010 started an experimental protocol to rule hearing aid provision in all INAIL centers, throughout Italy. Authors present first results of this protocol in Lombardy, related to previous and national ones.
Shabbir, Shagufta H.; Regan, Clinton J.; Anslyn, Eric V.
2009-01-01
A general approach to high-throughput screening of enantiomeric excess (ee) and concentration was developed by using indicator displacement assays (IDAs), and the protocol was then applied to the vicinal diol hydrobenzoin. The method involves the sequential utilization of what we define herein as screening, training, and analysis plates. Several enantioselective boronic acid-based receptors were screened by using 96-well plates, both for their ability to discriminate the enantiomers of hydrobenzoin and to find their optimal pairing with indicators resulting in the largest optical responses. The best receptor/indicator combination was then used to train an artificial neural network to determine concentration and ee. To prove the practicality of the developed protocol, analysis plates were created containing true unknown samples of hydrobenzoin generated by established Sharpless asymmetric dihydroxylation reactions, and the best ligand was correctly identified. PMID:19332790
Shabbir, Shagufta H; Regan, Clinton J; Anslyn, Eric V
2009-06-30
A general approach to high-throughput screening of enantiomeric excess (ee) and concentration was developed by using indicator displacement assays (IDAs), and the protocol was then applied to the vicinal diol hydrobenzoin. The method involves the sequential utilization of what we define herein as screening, training, and analysis plates. Several enantioselective boronic acid-based receptors were screened by using 96-well plates, both for their ability to discriminate the enantiomers of hydrobenzoin and to find their optimal pairing with indicators resulting in the largest optical responses. The best receptor/indicator combination was then used to train an artificial neural network to determine concentration and ee. To prove the practicality of the developed protocol, analysis plates were created containing true unknown samples of hydrobenzoin generated by established Sharpless asymmetric dihydroxylation reactions, and the best ligand was correctly identified.
The socioeconomic impact of hearing loss in U.S. adults.
Emmett, Susan D; Francis, Howard W
2015-03-01
To evaluate the associations between hearing loss and educational attainment, income, and unemployment/underemployment in U.S. adults. National cross-sectional survey. Ambulatory examination centers. Adults aged 20 to 69 years who participated in the 1999 to 2002 cycles of the NHANES (National Health and Nutrition Examination Survey) audiometric evaluation and income questionnaire (N = 3,379). Pure-tone audiometry, with hearing loss defined by World Health Organization criteria of bilateral pure-tone average of more than 25 dB (0.5, 1, 2, 4 kHz). Low educational attainment, defined as not completing high school; low income, defined as family income less than $20,000 per year; and unemployment or underemployment, defined as not having a job or working less than 35 hours per week. Individuals with hearing loss had 3.21 times higher odds of low educational attainment (95% confidence interval [95% CI], 2.20-4.68) compared with normal-hearing individuals. Controlling for education, age, sex, and race, individuals with hearing loss had 1.58 times higher odds of low income (95% CI, 1.16-2.15) and 1.98 times higher odds of being unemployed or underemployed (95% CI, 1.38-2.85) compared with normal-hearing individuals. Hearing loss is associated with low educational attainment in U.S. adults. Even after controlling for education and important demographic factors, hearing loss is independently associated with economic hardship, including both low income and unemployment/underemployment. The societal impact of hearing loss is profound in this nationally representative study and should be further evaluated with longitudinal cohorts. Received institutional review board approval (National Center for Health Statistics Institutional Review Board Protocol no. 98-12).
A significant number (80%) of organic contaminants that represent health risks in drinking water are better suited to screening by LC/MS rather than GC/MS analysis. We report progress with the draft Library System Protocol 1.1 from a round robin of private, state and federal lab...
Mouse mutants from chemically mutagenized embryonic stem cells
Munroe, Robert J.; Bergstrom, Rebecca A.; Zheng, Qing Yin; Libby, Brian; Smith, Richard; John, Simon W.M.; Schimenti, Kerry J.; Browning, Victoria L.; Schimenti, John C.
2010-01-01
The drive to characterize functions of human genes on a global scale has stimulated interest in large-scale generation of mouse mutants. Conventional germ-cell mutagenesis with N-ethyl-N-nitrosourea (ENU) is compromised by an inability to monitor mutation efficiency, strain1 and interlocus2 variation in mutation induction, and extensive husbandry requirements. To overcome these obstacles and develop new methods for generating mouse mutants, we devised protocols to generate germline chi-maeric mice from embryonic stem (ES) cells heavily mutagenized with ethylmethanesulphonate (EMS). Germline chimaeras were derived from cultures that underwent a mutation rate of up to 1 in 1,200 at the Hprt locus (encoding hypoxanthine guanine phosphoribosyl transferase). The spectrum of mutations induced by EMS and the frameshift mutagen ICR191 was consistent with that observed in other mammalian cells. Chimaeras derived from ES cells treated with EMS transmitted mutations affecting several processes, including limb development, hair growth, hearing and gametogenesis. This technology affords several advantages over traditional mutagenesis, including the ability to conduct shortened breeding schemes and to screen for mutant phenotypes directly in ES cells or their differentiated derivatives. PMID:10700192
Thamsborg, Lise Holst; Andersen, Berit; Larsen, Lise Grupe; Christensen, Jette; Johansen, Tonje; Hariri, Jalil; Christiansen, Sanne; Rygaard, Carsten; Lynge, Elsebeth
2018-05-26
The first birth cohorts of women offered human papillomavirus (HPV) vaccination as girls are now entering cervical screening. However, there is no international consensus on how to screen HPV vaccinated women. These women are better protected against cervical cancer and could therefore be offered less intensive screening. Primary HPV testing is more sensitive than cytology, allowing for a longer screening interval. The aim of Trial23 is to investigate if primary HPV testing with cytology triage of HPV positive samples is a reasonable screening scheme for women offered HPV vaccination as girls. Trial23 is a method study embedded in the existing cervical screening programme in four out of five Danish regions. Without affecting the screening programme, women born in 1994 are randomised to present screening with liquid-based cytology every third year (present programme arm) or present screening plus an HPV test (HPV arm). The study started 1 February 2017 and will run over three screening rounds corresponding to 7-8 years. The primary endpoint is cervical intraepithelial neoplasia grade 3 or above. The trial is undertaken as a non-inferiority study including intention-to-treat and per-protocol analyses. The potential effect of primary HPV screening with a 6-year interval will be calculated from the observed data. The study protocol has been submitted to the ethical committee and deemed a method study. All women are screened according to routine guidelines. The study will contribute new evidence on the future screening of HPV vaccinated birth cohorts of women. All results will be published in open-access journal. NCT03049553; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Valido Quintana, Mercedes; Oviedo Santos, Ángeles; Borkoski Barreiro, Silvia; Santana Rodríguez, Alfredo; Ramos Macías, Ángel
Sixty percent of prelingual hearing loss is of genetic origin. A family history of permanent childhood hearing loss is a risk factor. The objective of the study is to determine the relationship between this risk factor and hearing loss. We have evaluated clinical and epidemiological characteristics and related nonsyndromic genetic variation. This was a retrospective, descriptive and observational study of newborns between January 2007 and December 2010 with family history as risk factor for hearing loss using transient evoked otoacoustic emissions and auditory brainstem response. A total of 26,717 children were born. Eight hundred and fifty-seven (3.2%) had family history. Fifty-seven(0.21%) failed to pass the second test. A percentage of 29.1 (n=16) had another risk factor, and 17.8% (n=9) had no classical risk factor. No risk factor was related to the hearing loss except heart disease. Seventy-six point four percent had normal hearing and 23.6% hearing loss. The mean of family members with hearing loss was 1.25. On genetic testing, 82.86% of homozygotes was normal, 11.43% heterozygosity in Connexin 26 gene (35delG), 2.86% R143W heterozygosity in the same gene and 2.86% mutant homozygotes (35delG). We found no relationship between hearing loss and mutated allele. The percentage of children with a family history and hearing loss is higher than expected in the general population. The genetic profile requires updating to clarify the relationship between hearing loss and heart disease, family history and the low prevalence in the mutations analyzed. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Harger, Marília Rabelo Holanda Camarano; Barbosa-Branco, Anadergh
2004-01-01
To evaluate the prevalence of hearing loss, its degree and type, among workers in the marble industry in the Brazilian Federal District (FD). Workers from eight marble industries in the FD were evaluated by means of a cross sectional epidemiological study. An audiometry screening test (air conduction) was performed. Workers with hearing loss were submitted to liminal tonal audiometry air & bone conduction and speech audiometry tests using an audiometer AD-28 (Interacoustics). All subjects studied were submitted to a visual inspection of the external acoustic meatus. One hundred and fifty two workers were examined; mean age was 32 years (SD = 8.6); average occupational noise exposure was of 8.3 years (SD = 6.8). Audiometries demonstrated that 48.0% (n = 73) had some type of hearing loss. Among the workers with hearing loss, 50.0% had results compatible with noise-induced hearing loss (NIHL); 41.0% with incipient noise induced hearing loss, 5.0% with sensorineural hearing loss (all except NIHL) and 4.0% with conductive and mixed hearing losses. Among workers with NIHL, 57.1% had bilateral involvement, 17.1% in the right ear and 25.7% in the left ear. Among those with incipient NIHL, 13.9% were bilateral, 19.4% were only in the right ear and 66.7% were only in the left ear. Abnormal audiograms were found in 48.0% of the sample. Among those with hearing loss, the predominant cause was NIHL, followed by those classified as having incipient noise induced hearing loss. Hearing loss usually started at 6 kHz, frequently in the left ear.
... able to assess your child’s speech production and language development and make appropriate therapy recommendations. It is also ... pathologist should consistently assess your child’s speech and language development, as well as screen for hearing problems (with ...
School Health Screening of Indochinese Refugee Children.
ERIC Educational Resources Information Center
Pickwell, Sheila M.
1981-01-01
Indochinese children registering for the first time in American schools are appearing with multiple health problems. These frequently include lice and scabies, intestinal parasites, vision and hearing defects, and severe dental decay. (JN)
Peters, Remco P H; Verweij, Stephan P; Nijsten, Noëmi; Ouburg, Sander; Mutsaers, Johan; Jansen, Casper L; van Leeuwen, A Petra; Morré, Servaas A
2011-07-26
Sexually transmitted infection (STI) screening programmes are implemented in many countries to decrease burden of STI and to improve sexual health. Screening for Chlamydia trachomatis and Neisseria gonorrhoeae has a prominent role in these protocols. Most of the screening programmes concerning men having sex with men (MSM) are based on opportunistic urethral testing. In The Netherlands, a history-based approach is used. The aim of this study is to evaluate the protocol of screening anatomic sites for C. trachomatis and N. gonorrhoeae infection based on sexual history in MSM in routine practice in The Netherlands. All MSM visiting the clinic for STI in The Hague are routinely asked about their sexual practice during consulting. As per protocol, tests for urogenital, oropharyngeal and anorectal infection are obtained based on reported site(s) of sexual contact. All consultations are entered into a database as part of the national STI monitoring system. Data of an 18 months period were retrieved from this database and analysed. A total of 1455 consultations in MSM were registered during the study period. The prevalence of C. trachomatis and N. gonorrhoeae per anatomic site was: urethral infection 4.0% respectively and 2.8%, oropharynx 1.5% and 4.2%, and anorectum 8.2% and 6.0%. The majority of chlamydia cases (72%) involved a single anatomic site, which was especially manifest for anorectal infections (79%), while 42% of gonorrhoea cases were single site. Twenty-six percent of MSM with anorectal chlamydia and 17% with anorectal gonorrhoea reported symptoms of proctitis; none of the oropharyngeal infections were symptomatic. Most cases of anorectal infection (83%) and oropharyngeal infection (100%) would have remained undiagnosed with a symptom-based protocol. The current strategy of sexual-history based screening of multiple anatomic sites for chlamydia and gonorrhoea in MSM is a useful and valid guideline which is to be preferred over a symptom-based screening protocol.
Biodegradability study of high-erucic-acid-rapeseed-oil-based lubricant additives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, E.; Crawford, R.L.; Shanahan, A.
1995-12-31
A variety of high-erucic-acid-rapeseed (HEAR)-oil-based lubricants, lubricant additives, and greases were examined for biodegradability at the University of Idaho Center for Hazardous Waste Remediation Research. Two standard biodegradability tests were employed, a currently accepted US Environmental Protection Agency (EPA) protocol and the Sturm Test. As is normal for tests that employ variable inocula such as sewage as a source of microorganisms, these procedures yielded variable results from one repetition to another. However, a general trend of rapid and complete biodegradability of the HEAR-oil-based materials was observed.
Tawil, Rabi; Kissel, John T.; Heatwole, Chad; Pandya, Shree; Gronseth, Gary; Benatar, Michael
2015-01-01
Objective: To develop recommendations for the evaluation, diagnosis, prognostication, and treatment of facioscapulohumeral muscular dystrophy (FSHD) from a systematic review and analysis of the evidence. Methods: Relevant articles were analyzed in accordance with the American Academy of Neurology classification of evidence schemes for diagnostic, prognostic, and treatment studies. Recommendations were linked to the strength of the evidence and other factors. Results and recommendations: Available genetic testing for FSHD type 1 is highly sensitive and specific. Although respiratory insufficiency occurs rarely in FSHD, patients with severe FSHD should have routine pulmonary function testing. Routine cardiac screening is not necessary in patients with FSHD without cardiac symptoms. Symptomatic retinal vascular disease is very rare in FSHD. Exudative retinopathy, however, is potentially preventable, and patients with large deletions should be screened through dilated indirect ophthalmoscopy. The prevalence of clinically relevant hearing loss is not clear. In clinical practice, patients with childhood-onset FSHD may have significant hearing loss. Because undetected hearing loss may impair language development, screening through audiometry is recommended for such patients. Musculoskeletal pain is common in FSHD and treating physicians should routinely inquire about pain. There is at present no effective pharmacologic intervention in FSHD. Available studies suggest that scapular fixation is safe and effective. Surgical scapular fixation might be cautiously offered to selected patients. Aerobic exercise in FSHD appears to be safe and potentially beneficial. On the basis of the evidence, patients with FSHD might be encouraged to engage in low-intensity aerobic exercises. PMID:26215877
ERIC Educational Resources Information Center
Cone-Wesson, Barbara
1995-01-01
This article discusses the accuracy of bone-conduction auditory brainstem response (BC-ABR) tests to determine the presence and severity of conductive hearing impairment. It provides warnings about technical pitfalls and recommends incorporating BC-ABR protocols for routine clinical use. It concludes that the method allows estimating cochlear…
Protocol of a randomized controlled trial of hearing protection interventions for farm operators.
McCullagh, Marjorie C; Ronis, David L
2015-04-18
Hearing loss and tinnitus are prevalent in America, and noise-induced hearing loss is a leading cause of hearing loss. Noise-induced hearing loss has negative impact on quality of life, physical and emotional functioning, social life, and employment. In addition, noise-induced hearing loss results in heavy social and economic burdens on families and communities from all ethnic and socioeconomic groups. Farmers are a group that is particularly high risk for noise-induced hearing loss, and is underserved by programs designed to limit that risk. They are among the most noise-exposed group of workers, and experience the second highest prevalence of noise-induced hearing loss among all occupational categories. In agriculture, 1.5 million workers (43.3%) report exposure to hazardous noise. Although use of hearing protection devices (HPDs) would protect them from noise-induced hearing loss, use among farmers is low. The purpose of this project is to compare the effectiveness of several approaches to influencing hearing protector use. Approaches include: a) an interactive, predictors-based intervention delivered via the Internet; b) a static informational web site; and c) a mailed sampler of hearing protectors. The goals are to further develop an intervention to promote farmers' use of HPDs, and compare the effectiveness of the interventions delivered in various combinations. Participants will include 701 farmers. Sites will be affiliates of a major farmer organization. Data will be collected at baseline, 6, and 12 months. A random intercept mixed model will be used to explore the fixed effects of the three NIHL prevention interventions over time while adjusting for age and gender. This project will involve a partnership between the University of Michigan and a major farmer organization to accomplish project aims. Results of this study will be used to inform future research-to-practice studies to increase hearing protector use. Increased use of hearing protectors is expected to reduce rates of noise-induced hearing loss and other negative effects of high noise exposure, and improve quality of life in this high-risk and underserved group. Clinicaltrials.gov NCT01454895 Registered 14 October, 2011.
Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results.
Ari-Even Roth, Daphne; Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael
2016-12-06
The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. © The Author(s) 2016.
Results of newborn screening for hearing loss: effects on the family in the first 2 years of life.
Vohr, Betty R; Jodoin-Krauzyk, Julie; Tucker, Richard; Johnson, Mary Jane; Topol, Deborah; Ahlgren, Marianne
2008-03-01
To determine whether there was increased stress and impact on the family for mothers of infants whose screening results and subsequent diagnostic findings indicated hearing loss (HL) and mothers of infants with a positive screening result who subsequently pass the rescreening (false-positive group), compared with mothers of infants who pass the initial screening (control group), when their children were aged 6 to 10, 12 to 16, and 18 to 24 months. Matched cohort analytic study. Home visits. Patients/ Mothers of 33 infants with confirmed HL, 42 infants with a false-positive screening result, and 70 infants in the control group. Screening for HL. Scores on the Parenting Stress Index and the Impact on Family-Adapted Version G. Mothers of infants in the false-positive group did not report increased stress or impact. Mothers of infants with HL reported greater financial impact, total impact, and caretaker burden compared with mothers of infants in the control group. In multivariate analysis of the total cohort, the presence of HL was associated with increased total impact on the family; a neonatal intensive care unit stay was associated with increased stress and total impact on the family; and older maternal age and greater family resources were associated with decreased stress and total impact on the family. Although a false-positive result or a pass of the screening for HL was not associated with increased stress or impact, identification of HL was independently associated with greater total impact on the family when the child was 18 to 24 months of age.
Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results
Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael
2016-01-01
The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. PMID:27927982
Meijerink, Janine Fj; Pronk, Marieke; Paulissen, Bernadette; Witte, Birgit I; Wouden, Bregje van der; Jansen, Vera; Kramer, Sophia E
2017-06-20
An educational SUpport PRogramme called SUPR has been developed for hearing aid users (HAUs) and their communication partners (CPs) offering care beyond hearing aid fitting. SUPR teaches its users communication strategies, hearing aid handling skills and personal adjustment to hearing impairment. Using a cluster randomised controlled trial design, 70 Dutch hearing aid dispenser practices were randomised into hearing aid fitting (care as usual, 34 practices) and hearing aid fitting including SUPR (36 practices). The aim was to recruit a total of 569 older (aged 50+ years) first-time (n=258) and experienced (n=311) HAUs and their CPs. SUPR consists of a Practical Support Booklet and online material offered via email over a period of 6-7 months. The booklet provides practical information on hearing aids, advice on communication strategies and home exercises. The online material consists of educational videos on hearing aid functionality and usage, communication strategies and peer testimonials. Finally, noncommittal email contact with the dispenser is offered. Every HAU is asked to assign a CP who is advised to be involved intensively. Effect measurements for HAUs and their CPs will occur at baseline and at 6, 12 and 18 months follow-up via online questionnaires. The primary outcomes for HAUs will be the use of communication strategies as measured by the subscales of the Communication Profile for the Hearing Impaired. A process evaluation will be performed. The study was approved by the Dutch Institutional Review Board of the VU Medical University Center Amsterdam. This intervention could contribute to lowering the hearing impairment burden in our ageing society. The results will be disseminated through peer-reviewed publications and scientific conferences. ISRCTN77340339; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
GALLUS, R.; DE CARLINI, M.; PICCIOTTI, P.M.; MUZZI, E.; CICIRIELLO, E.; ORZAN, E.; CONTI, G.
2016-01-01
SUMMARY Diagnosis of child permanent hearing impairment (PHI) can be made with extreme timeliness compared to the past thanks to improvements in PHI identification through newborn hearing screening programmes. It now becomes essential to provide an effective amplification as quickly as possible in order to restore auditory function and favour speech and language development. The early fitting of hearing aids and possible later cochlear implantation indeed prompts the development of central auditory pathways, connections with secondary sensory brain areas, as well as with motor and articulatory cortex. The aim of this paper is to report the results of a strategic analysis that involves identification of strengths, weaknesses, opportunities and threats regarding the process of achieving early amplification in all cases of significant childhood PHI. The analysis is focused on the Italian situation and is part of the Italian Ministry of Health project CCM 2013 "Preventing Communication Disorders: a Regional Program for Early Identification, Intervention and Care of Hearing Impaired Children". PMID:27054389
Kubba, H; Smyth, A; Wong, S C; Mason, A
2017-06-01
Turner's syndrome (TS) is a common chromosomal disorder, affecting one in 2000 newborn girls, in which part or all of one X chromosome is missing. Ear and hearing problems are very common in girls and women with TS. The aim of this review was to review the published literature to suggest recommendations for otological health surveillance. A keyword search of Ovid Medline was performed for published literature on the subject and evidence rated according to the GRADE criteria. Middle ear disorders are very common and persistent in girls and women with TS as are progressive sensorineural hearing loss and balance disorders. Otolaryngologists should be aware of the high prevalence and challenging nature of all forms of ear disease in individuals with TS. Early intervention may offer benefits to health and education, and we advocate routine lifelong annual hearing screening in this group. © 2016 John Wiley & Sons Ltd.
Association Between Childhood Hearing Disorders and Tinnitus in Adulthood.
Aarhus, Lisa; Engdahl, Bo; Tambs, Kristian; Kvestad, Ellen; Hoffman, Howard J
2015-11-01
The association between childhood hearing disorders and adult tinnitus has not been examined in longitudinal cohort studies. To determine the association between different types of childhood hearing loss and tinnitus in adulthood and evaluate whether tinnitus risk is mediated by adult hearing loss. Population-based cohort study of 32 430 adults (aged 20-56 years) who underwent pure-tone audiometry and completed a tinnitus questionnaire in the Nord-Trøndelag Hearing Loss Study, which was a part of the Nord-Trøndelag Health Study 2 (HUNT2). The study was conducted from January 1, 2014, to April 1, 2015. Data analysis was performed from April 1, 2014, to April 1, 2015. As children, the same individuals had undergone screening audiometry in a longitudinal primary school hearing investigation, including ear, nose, and throat examinations when indicated. Pure-tone audiometry, questionnaires, and ear, nose, and throat examinations. Self-reported tinnitus (yes or no) in adulthood measured by questionnaires. Adults who had hearing loss at the time of the school investigation (n = 3026) reported more tinnitus, measured as odds ratio (95% CI), than did adults with normal childhood hearing (n = 29 404) (1.4 [1.3-1.6]). Childhood hearing disorders associated with tinnitus in adulthood included sensorineural hearing loss, chronic suppurative otitis media, and hearing loss associated with a history of recurrent acute otitis media (2.4 [1.9-3.0], 2.4 [1.5-3.9], and 1.6 [1.3-2.0], respectively). These estimates were adjusted for age, sex, and noise exposure in adulthood. After further analyses that included adjustment for adult hearing threshold, none of these childhood hearing disorders remained positively associated with tinnitus. Childhood hearing disorders associated with tinnitus in adulthood include sensorineural hearing loss, chronic suppurative otitis media, and hearing loss associated with a history of recurrent acute otitis media. After adjustment for the adult hearing threshold, none of the childhood hearing disorders was positively associated with tinnitus. Hence, it appears that these significant associations are mediated or transmitted through adult hearing loss.
Improving hearing health for farming families.
Lower, Tony; Fragar, Lyn; Depcynzksi, Julie; Challinor, Kathy; Mills, Jan; Williams, Warwick
2010-01-01
Occupational noise injury and hearing loss are common features of agricultural workforces internationally. Farmsafe Australia has identified hearing health as one of its 4 key priority goals and targets. Currently, approximately 60-70% of Australian farmers have measurable hearing loss, compared with 27% of those in the general Australian community. This article describes the findings of a community based demonstration project to address hearing health issues conducted in the Australian state of New South Wales. This program sought to implement local demonstration projects in 3 communities to identify what works well in hearing health promotion with farmers and what could be applied more broadly throughout Australia. Local advisory groups were established in each community to guide project development and implementation. Project implementation focused on 3 major aspects: (1) increasing awareness of priority noise injury prevention and hearing health practices; (2) improving access to hearing health services; and (3) networking services in local communities. Area-specific training was undertaken for stakeholders to maximize local information links. Service utilization data were monitored and analysed. There was variability among sites; however in general there was an increased awareness of hearing health issues by farming families and expanded opportunities for farmers to access screening services. Utilization rates of hearing services also increased markedly in one community. Local hearing health networks were strengthened by linkages to key stakeholders outside the health sector. Previously unidentified methods of promoting hearing health (eg using agricultural retail outlets that supply hearing protection equipment and are accepted by farmers as an information source) were identified and utilized. Hearing health promotion with farmers in local communities can be enhanced through utilization and strengthening of local networks. Integration of hearing health initiatives with other agencies already working with farming families will be important in developing and enhancing long-term sustainable outcomes. Continued work at a national level to assist in stimulating local action will be required to build on the potential gains in reducing noise injury in the farming community.
Yamamoto, Aparecida Y; Mussi-Pinhata, Marisa Marcia; Isaac, Myriam de Lima; Amaral, Fabiana R; Carvalheiro, Cristina G; Aragon, Davi C; Manfredi, Alessandra K da Silva; Boppana, Suresh B; Britt, William J
2011-12-01
The burden of congenital cytomegalovirus (CMV)-associated sensorineural hearing loss (SNHL) in populations with CMV seroprevalence approaching 100% is unknown. The purpose of this study was to assess the rate, associated factors, and predictors of SNHL in CMV-infected infants identified by newborn screening in a highly seropositive maternal population. Newborns with positive saliva CMV-DNA that was confirmed by virus isolation in the first 2 weeks of life were enrolled in a prospective follow-up study to monitor hearing outcome. Of 12,195 infants screened, 121 (1%) were infected with CMV and 12 (10%) had symptomatic infection at birth. Hearing function could be assessed in 102/121 children who underwent at least one auditory brainstem evoked response testing at a median age of 12 months. SNHL was observed in 10/102 (9.8%; 95% confidence interval: 5.1-16.7) children. Median age at the latest hearing evaluation was 47 months (12-84 months). Profound loss (>90 dB) was found in 4/5 children with bilateral SNHL while all 5 children with unilateral loss had moderate to severe deficit. The presence of symptomatic infection at birth (odds ratio, 38.1; 95% confidence interval: 1.6-916.7) was independently associated with SNHL after adjusting for intrauterine growth restriction, gestational age, gravidity, and maternal age. Among 10 infants with SNHL, 6 (60%) were born to mothers with nonprimary CMV infection. Even in populations with near universal immunity to CMV, congenital CMV infection is a significant cause of SNHL demonstrating the importance of CMV as a major cause of SNHL in children worldwide. As in other populations, SNHL is more frequently observed in symptomatic CMV infection.
Development and evaluation of the LittlEARS® Early Speech Production Questionnaire - LEESPQ.
Wachtlin, Bianka; Brachmaier, Joanna; Amann, Edda; Hoffmann, Vanessa; Keilmann, Annerose
2017-03-01
Universal Newborn Hearing Screening programs, now instituted throughout the German-speaking countries, allow hearing loss to be detected and treated much earlier than ever before. With this earlier detection, arises the need for tools fit for assessing the very early speech and language production development of today's younger (0-18 month old) children. We have created the LittlEARS ® Early Speech Production Questionnaire, with the aim of meeting this need. 600 questionnaires of the pilot version of the LittlEARS ® Early Speech Production Questionnaire were distributed to parents via pediatricians' practices, day care centers, and personal contact. The completed questionnaires were statistically analyzed to determine their reliability, predictive accuracy, internal consistency, and to what extent gender or unilingualism influenced a child's score. Further, a norm curve was generated to plot the children's increased expected speech production ability with age. Analysis of the data from the 352/600 returned questionnaires revealed that scores on LittlEARS ® Early Speech Production Questionnaire correlate positively with a child's age, with older children scoring higher than do younger children. Further, the questionnaire has a high measuring reliability, high predictability, high unidemensionality of scale, and is not significantly gender or uni-/multilingually biased. A norm curve for expected development with age was created. The LittlEARS ® Early Speech Production Questionnaire (LEESPQ) is a valid tool for assessing the most important milestones in very early development of speech and language production of German language children with normal hearing aged 0-18 months old. The questionnaire is a potentially useful tool for long-term infant screening and follow-up testing and for children with normal hearing and those who would benefit from or use hearing devices. Copyright © 2017 Elsevier B.V. All rights reserved.
The history of sign language and deaf education in Turkey.
Kemaloğlu, Yusuf Kemal; Kemaloğlu, Pınar Yaprak
2012-01-01
Sign language is the natural language of the prelingually deaf people particularly without hearing-speech rehabilitation. Otorhinolaryngologists, regarding health as complete physical, mental and psychosocial well-being, aim hearing by diagnosing deafness as deviance from normality. However, it's obvious that the perception conflicted with the behavior which does not meet the mental and social well-being of the individual also contradicts with the definition mentioned above. This article aims to investigate the effects of hearing-speech target ignoring the sign language in Turkish population and its consistency with the history through statistical data, scientific publications and historical documents and to support critical perspective on this issue. The study results showed that maximum 50% of the deaf benefited from hearing-speech program for last 60 years before hearing screening programs; however, systems including sign language in education were not generated. In the light of these data, it is clear that the approach ignoring sign language particularly before the development of screening programs is not reasonable. In addition, considering sign language being part of the Anatolian history from Hittites to Ottomans, it is a question to be answered that why evaluation, habilitation and education systems excluding sign language are still the only choice for deaf individuals in Turkey. Despite legislative amendments in the last 6-7 years, the primary cause of failure to come into force is probably because of inadequate conception of the issue content and importance, as well as limited effort to offer solutions by academicians and authorized politicians. Within this context, this paper aims to make a positive effect on this issue offering a review for the medical staff, particularly otorhinolaryngologists and audiologists.
Sequi-Canet, José M; Sala-Langa, María J; Collar Del Castillo, José I
2014-01-01
Most hospitals perform neonatal hearing screening because it is a very useful procedure. Otoacoustic emissions are an ideal technique for this screening. We analyse the possible influence on screening results of some perinatal factors. We collected retrospective data from 8,239 healthy newborns delivered vaginally at the maternity ward of our hospital. We compared multiple perinatal factors vs the results of otoacoustic emissions performed within the first 48 h of life, before discharge. A total of 6.4% of newborns had an abnormal response and failed the screening. Univariate and multivariate analysis showed a significant (P<.0001) positive relationship between breastfeeding and normal otoacoustic emissions (OR: 0.65). Another, less significant factor was female gender. The remaining variables, including origin, education or employment status of the mother, maternal smoking, dystocic delivery, presentation, need for resuscitation, preterm labour (34-36 weeks), weight, length and frequent maternal pathology, such as streptococcus detection, hypothyroidism, hypertension or diabetes, were not significant. Breastfeeding was the most important factor related to a normal response in otoacoustic emissions. It may improve final results and reduce the number of neonates who need to be rescheduled for a repeated test, as well as the associated anxiety and the possibility of losing patients during follow-up. These are major problems in neonatal hearing screening. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Behavioral Screening for Toxicology | Science Inventory | US ...
Screening for behavioral toxicity, or neurotoxicity, has been in use for decades; however, only in the past 20 years has this become a standard practice in toxicology. Current screening batteries, such as the functional observational battery (FOB), are derived from protocols used in pharmacology, toxicology, and psychology. Although there is a range of protocols in use today, all focus on detailed observations and specific tests of reflexes and responses. Several neurological functions are typically assessed, including autonomic, neuromuscular, and sensory, as well as levels of activity and excitability. The tests have been shown to be valid in detecting expected effects of known neurotoxicants, and reliable and reproducible whn compared across laboratories. Regardless of the specific protocol used, proper conduct and statistical analyses of the data are critical. Interpretation is based on the information from individual end points as well as the profile, or pattern, of effects observed. As long as continual refinements are made, behavioral screening methods will continue to be important tools with which to protect human health in the future.autonomic function; behavior; behavioral phenotypes; behavioral toxicity; excitability; functional observational battery ; motor activity; mouse; neuromuscular function; positive controls; rat; screening battery ; sensory function Screening for behavioral toxicity, or neurotoxicity, has been in use for decades; how
Potgieter, Jenni-Marí; Swanepoel, De Wet; Myburgh, Hermanus Carel; Smits, Cas
2017-11-20
This study determined the effect of hearing loss and English-speaking competency on the South African English digits-in-noise hearing test to evaluate its suitability for use across native (N) and non-native (NN) speakers. A prospective cross-sectional cohort study of N and NN English adults with and without sensorineural hearing loss compared pure-tone air conduction thresholds to the speech reception threshold (SRT) recorded with the smartphone digits-in-noise hearing test. A rating scale was used for NN English listeners' self-reported competence in speaking English. This study consisted of 454 adult listeners (164 male, 290 female; range 16 to 90 years), of whom 337 listeners had a best ear four-frequency pure-tone average (4FPTA; 0.5, 1, 2, and 4 kHz) of ≤25 dB HL. A linear regression model identified three predictors of the digits-in-noise SRT, namely, 4FPTA, age, and self-reported English-speaking competence. The NN group with poor self-reported English-speaking competence (≤5/10) performed significantly (p < 0.01) poorer than the N and NN (≥6/10) groups on the digits-in-noise test. Screening characteristics of the test improved with separate cutoff values depending on English-speaking competence for the N and NN groups (≥6/10) and NN group alone (≤5/10). Logistic regression models, which include age in the analysis, showed a further improvement in sensitivity and specificity for both groups (area under the receiver operating characteristic curve, 0.962 and 0.903, respectively). Self-reported English-speaking competence had a significant influence on the SRT obtained with the smartphone digits-in-noise test. A logistic regression approach considering SRT, self-reported English-speaking competence, and age as predictors of best ear 4FPTA >25 dB HL showed that the test can be used as an accurate hearing screening tool for N and NN English speakers. The smartphone digits-in-noise test, therefore, allows testing in a multilingual population familiar with English digits using dynamic cutoff values that can be chosen according to self-reported English-speaking competence and age.
Griest, Susan; Zaugg, Tara L.; Thielman, Emily; Kaelin, Christine; Galvez, Gino; Carlson, Kathleen F.
2015-01-01
Purpose Individuals complaining of tinnitus often attribute hearing problems to the tinnitus. In such cases some (or all) of their reported “tinnitus distress” may in fact be caused by trouble communicating due to hearing problems. We developed the Tinnitus and Hearing Survey (THS) as a tool to rapidly differentiate hearing problems from tinnitus problems. Method For 2 of our research studies, we administered the THS twice (mean of 16.5 days between tests) to 67 participants who did not receive intervention. These data allow for measures of statistical validation of the THS. Results Reliability of the THS was good to excellent regarding internal consistency (α = .86–.94), test–retest reliability (r = .76–.83), and convergent validity between the Tinnitus Handicap Inventory (Newman, Jacobson, & Spitzer, 1996; Newman, Sandridge, & Jacobson, 1998) and the A (Tinnitus) subscale of the THS (r = .78). Factor analysis confirmed that the 2 subscales, A (Tinnitus) and B (Hearing), have strong internal structure, explaining 71.7% of the total variance, and low correlation with each other (r = .46), resulting in a small amount of shared variance (21%). Conclusion These results provide evidence that the THS is statistically validated and reliable for use in assisting patients and clinicians in quickly (and collaboratively) determining whether intervention for tinnitus is appropriate. PMID:25551458
Harris, Margaret; Terlektsi, Emmanouela; Kyle, Fiona E
2017-03-01
In this study, we compared the language and literacy of two cohorts of children with severe-profound hearing loss, recruited 10 years apart, to determine if outcomes had improved in line with the introduction of newborn hearing screening and access to improved hearing aid technology. Forty-two children with deafness, aged 5-7 years with a mean unaided loss of 102 DB, were assessed on language, reading, and phonological skills. Their performance was compared with that of a similar group of 32 children with deafness assessed 10 years earlier and also a group of 40 children with normal hearing of similar single word reading ability. English vocabulary was significantly higher in the new cohort although it was still below chronological age. Phonological awareness and reading ability had not significantly changed over time. In both cohorts, English vocabulary predicted reading, but phonological awareness was only a significant predictor for the new cohort. The current results show that vocabulary knowledge of children with severe-profound hearing loss has improved over time, but there has not been a commensurate improvement in phonological skills or reading. They suggest that children with severe-profound hearing loss will require continued support to develop robust phonological coding skills to underpin reading.
Bess, F H; Dodd-Murphy, J; Parker, R A
1998-10-01
This study was designed to determine the prevalence of minimal sensorineural hearing loss (MSHL) in school-age children and to assess the relationship of MSHL to educational performance and functional status. To determine prevalence, a single-staged sampling frame of all schools in the district was created for 3rd, 6th, and 9th grades. Schools were selected with probability proportional to size in each grade group. The final study sample was 1218 children. To assess the association of MSHL with educational performance, children identified with MSHL were assigned as cases into a subsequent case-control study. Scores of the Comprehensive Test of Basic Skills (4th Edition) (CTBS/4) then were compared between children with MSHL and children with normal hearing. School teachers completed the Screening Instrument for Targeting Education Risk (SIFTER) and the Revised Behavior Problem Checklist for a subsample of children with MSHL and their normally hearing counterparts. Finally, data on grade retention for a sample of children with MSHL were obtained from school records and compared with school district norm data. To assess the relationship between MSHL and functional status, test scores of all children with MSHL and all children with normal hearing in grades 6 and 9 were compared on the COOP Adolescent Chart Method (COOP), a screening tool for functional status. MSHL was exhibited by 5.4% of the study sample. The prevalence of all types of hearing impairment was 11.3%. Third grade children with MSHL exhibited significantly lower scores than normally hearing controls on a series of subtests of the CTBS/4; however, no differences were noted at the 6th and 9th grade levels. The SIFTER results revealed that children with MSHL scored poorer on the communication subtest than normal-hearing controls. Thirty-seven percent of the children with MSHL failed at least one grade. Finally, children with MSHL exhibited significantly greater dysfunction than children with normal hearing on several subtests of the COOP including behavior, energy, stress, social support, and self-esteem. The prevalence of hearing loss in the schools almost doubles when children with MSHL are included. This large, education-based study shows clinically important associations between MSHL and school behavior and performance. Children with MSHL experienced more difficulty than normally hearing children on a series of educational and functional test measures. Although additional research is necessary, results suggest the need for audiologists, speech-language pathologists, and educators to evaluate carefully our identification and management approaches with this population. Better efforts to manage these children could result in meaningful improvement in their educational progress and psychosocial well-being.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.
High-throughput behavioral screening method for detecting auditory response defects in zebrafish.
Bang, Pascal I; Yelick, Pamela C; Malicki, Jarema J; Sewell, William F
2002-08-30
We have developed an automated, high-throughput behavioral screening method for detecting hearing defects in zebrafish. Our assay monitors a rapid escape reflex in response to a loud sound. With this approach, 36 adult zebrafish, restrained in visually isolated compartments, can be simultaneously assessed for responsiveness to near-field 400 Hz sinusoidal tone bursts. Automated, objective determinations of responses are achieved with a computer program that obtains images at precise times relative to the acoustic stimulus. Images taken with a CCD video camera before and after stimulus presentation are subtracted to reveal a response to the sound. Up to 108 fish can be screened per hour. Over 6500 fish were tested to validate the reliability of the assay. We found that 1% of these animals displayed hearing deficits. The phenotypes of non-responders were further assessed with radiological analysis for defects in the gross morphology of the auditory system. Nearly all of those showed abnormalities in conductive elements of the auditory system: the swim bladder or Weberian ossicles. Copyright 2002 Elsevier Science B.V.
Guillen-Ahlers, Hector; Erbe, Christy B; Chevalier, Frédéric D; Montoya, Maria J; Zimmerman, Kip D; Langefeld, Carl D; Olivier, Michael; Runge, Christina L
2018-04-19
Sensorineural hearing loss (SNHL) is a common form of hearing loss that can be inherited or triggered by environmental insults; auditory neuropathy spectrum disorder (ANSD) is a SNHL subtype with unique diagnostic criteria. The genetic factors associated with these impairments are vast and diverse, but causal genetic factors are rarely characterized. A family dyad, both cochlear implant recipients, presented with a hearing history of bilateral, progressive SNHL, and ANSD. Whole-exome sequencing was performed to identify coding sequence variants shared by both family members, and screened against genes relevant to hearing loss and variants known to be associated with SNHL and ANSD. Both family members are successful cochlear implant users, demonstrating effective auditory nerve stimulation with their devices. Genetic analyses revealed a mutation (rs35725509) in the TMTC2 gene, which has been reported previously as a likely genetic cause of SNHL in another family of Northern European descent. This study represents the first confirmation of the rs35725509 variant in an independent family as a likely cause for the complex hearing loss phenotype (SNHL and ANSD) observed in this family dyad. © 2018 The Authors. Molecular Genetics & Genomic Medicine published by Wiley Periodicals, Inc.
Cross-cultural adaptation of an Arabic version of the 10-item hearing handicap inventory.
Weinstein, Barbara E; Rasheedy, Doha; Taha, Hend M; Fatouh, Fathy N
2015-05-01
The purpose of this study was to translate and culturally adapt an Arabic version of the hearing handicap inventory for the elderly - screening (HHIE-S). The HHIE-S was translated following cross-cultural adaptation guidelines, and pretested in 20 elderly patients with hearing impairment. Next, the adapted Arabic HHIE-S underwent psychometric evaluation. The results were confirmed by pure-tone audiometer (PTA) examination. The patients completed the HHIE-S again after one hour. The validation of the questionnaire using Cronbach's alpha (internal consistency), (construct validity), and intraclass correlation coefficients (repeatability) was performed. Twenty elderly subjects with hearing impairment were recruited for the pretesting stage, and 100 elderly subjects were recruited for the psychometric evaluation stage. Patients with acute illness, functional dependency, cognitive impairment, and previous users of hearing aids were excluded. The adapted Arabic HHIE-S showed good internal consistency (α = 0.902). Construct validity was good, as high correlations were found between the scale and the PTA outcome (r = 0.688, p = 0.000). Repeatability was high (ICC = 0.986). This study showed that the adapted Arabic HHIE-S is a valid and reliable questionnaire for the assessment of handicapping hearing impairment in Egyptian elderly patients.
Hearing loss in former prisoners of war of the Japanese.
Grossman, T W; Kerr, H D; Byrd, J C
1996-09-01
To describe the prevalence, degree, and types of hearing loss present in a group of older American veterans who had been prisoners of war of the Japanese. A descriptive study. A Veterans Affairs university hospital. Seventy-five male veterans, mean age 68 (+/- 3.6) years. Hearing aids were prescribed for eight veterans. Subjects were examined, and pure tone air and bone conduction, speech reception threshold, and speech discrimination were determined. Results were compared with age- and sex-matched controls from the largest recent American population study of hearing loss. 95% of subjects had been imprisoned longer than 33 months. Starvation conditions (100%), head trauma (85%), and trauma-related loss of consciousness (23%) were commonly reported. A total of 73% complained of hearing loss, and 29% (22/75) dated its onset to captivity. Most of those with the worst losses in hearing and speech discrimination were found in this subgroup. When the entire group was compared with published age- and sex-matched controls from the Framingham Study, no significant differences were found. We advocate screening examinations and long-term follow-up of populations with similar histories of starvation, head trauma, and torture.
Speak on time! Effects of a musical rhythmic training on children with hearing loss.
Hidalgo, Céline; Falk, Simone; Schön, Daniele
2017-08-01
This study investigates temporal adaptation in speech interaction in children with normal hearing and in children with cochlear implants (CIs) and/or hearing aids (HAs). We also address the question of whether musical rhythmic training can improve these skills in children with hearing loss (HL). Children named pictures presented on the screen in alternation with a virtual partner. Alternation rate (fast or slow) and the temporal predictability (match vs mismatch of stress occurrences) were manipulated. One group of children with normal hearing (NH) and one with HL were tested. The latter group was tested twice: once after 30 min of speech therapy and once after 30 min of musical rhythmic training. Both groups of children (NH and with HL) can adjust their speech production to the rate of alternation of the virtual partner. Moreover, while children with normal hearing benefit from the temporal regularity of stress occurrences, children with HL become sensitive to this manipulation only after rhythmic training. Rhythmic training may help children with HL to structure the temporal flow of their verbal interactions. Copyright © 2017 Elsevier B.V. All rights reserved.
Consequences of Early Conductive Hearing Loss on Long-Term Binaural Processing.
Graydon, Kelley; Rance, Gary; Dowell, Richard; Van Dun, Bram
The aim of the study was to investigate the long-term effects of early conductive hearing loss on binaural processing in school-age children. One hundred and eighteen children participated in the study, 82 children with a documented history of conductive hearing loss associated with otitis media and 36 controls who had documented histories showing no evidence of otitis media or conductive hearing loss. All children were demonstrated to have normal-hearing acuity and middle ear function at the time of assessment. The Listening in Spatialized Noise Sentence (LiSN-S) task and the masking level difference (MLD) task were used as the two different measures of binaural interaction ability. Children with a history of conductive hearing loss performed significantly poorer than controls on all LiSN-S conditions relying on binaural cues (DV90, p = <0.001 and SV90, p = 0.003). No significant difference was found between the groups in listening conditions without binaural cues. Fifteen children with a conductive hearing loss history (18%) showed results consistent with a spatial processing disorder. No significant difference was observed between the conductive hearing loss group and the controls on the MLD task. Furthermore, no correlations were found between LiSN-S and MLD. Results show a relationship between early conductive hearing loss and listening deficits that persist once hearing has returned to normal. Results also suggest that the two binaural interaction tasks (LiSN-S and MLD) may be measuring binaural processing at different levels. Findings highlight the need for a screening measure of functional listening ability in children with a history of early otitis media.
Federici, Stefano; Stefano, Federici; Borsci, Simone; Stamerra, Gianluca
2010-08-01
A verbal protocol technique, adopted for a web usability evaluation, requires that the users are able to perform a double task: surfing and talking. Nevertheless, when blind users surf by using a screen reader and talk about the way they interact with the computer, the evaluation is influenced by a structural interference: users are forced to think aloud and listen to the screen reader at the same time. The aim of this study is to build up a verbal protocol technique for samples of visual impaired users in order to overcome the limits of concurrent and retrospective protocols. The technique we improved, called partial concurrent thinking aloud (PCTA), integrates a modified set of concurrent verbalization and retrospective analysis. One group of 6 blind users and another group of 6 sighted users evaluated the usability of a website using PCTA. By estimating the number of necessary users by the means of an asymptotic test, it was found out that the two groups had an equivalent ability of identifying usability problems, both over 80%. The result suggests that PCTA, while respecting the properties of classic verbal protocols, also allows to overcome the structural interference and the limits of concurrent and retrospective protocols when used with screen reader users. In this way, PCTA reduces the efficiency difference of usability evaluation between blind and sighted users.
Automated recycling of chemistry for virtual screening and library design.
Vainio, Mikko J; Kogej, Thierry; Raubacher, Florian
2012-07-23
An early stage drug discovery project needs to identify a number of chemically diverse and attractive compounds. These hit compounds are typically found through high-throughput screening campaigns. The diversity of the chemical libraries used in screening is therefore important. In this study, we describe a virtual high-throughput screening system called Virtual Library. The system automatically "recycles" validated synthetic protocols and available starting materials to generate a large number of virtual compound libraries, and allows for fast searches in the generated libraries using a 2D fingerprint based screening method. Virtual Library links the returned virtual hit compounds back to experimental protocols to quickly assess the synthetic accessibility of the hits. The system can be used as an idea generator for library design to enrich the screening collection and to explore the structure-activity landscape around a specific active compound.
Genetics of Hearing Loss – Syndromic
Koffler, Tal; Ushakov, Kathy; Avraham, Karen B.
2015-01-01
Synopsis Hearing loss (HL) is one of the most common birth defects in developed countries and is a diverse pathology with different classifications. One of these is based on the association with other clinical features, defined as syndromic hearing loss (SHL). Determining the etiology of the HL in these patients is extremely beneficial as it enables a personalized approach to caring for the individual. Early screening can further aid in optimal rehabilitation for a child’s development and growth. Pathogenic variants in forty-five genes, encoding proteins functioning as ion channels, transcription factors, molecular motors and more, are known to lead to eleven forms of SHL. The development of high-throughput sequencing technology is facilitating rapid and low-cost diagnostics for patients with SHL. PMID:26443487
Prevalence and causes of hearing impairment in Africa.
Mulwafu, W; Kuper, H; Ensink, R J H
2016-02-01
To systematically assess the data on the prevalence and causes of hearing impairment in Africa. Systematic review on the prevalence and causes of hearing loss in Africa. We undertook a literature search of seven electronic databases (EMBASE, PubMed, Medline, Global Health, Web of Knowledge, Academic Search Complete and Africa Wide Information) and manually searched bibliographies of included articles. The search was restricted to population-based studies on hearing impairment in Africa. Data were extracted using a standard protocol. We identified 232 articles and included 28 articles in the final analysis. The most common cut-offs used for hearing impairment were 25 and 30 dB HL, but this ranged between 15 and 40 dB HL. For a cut-off of 25 dB, the median was 7.7% for the children- or school-based studies and 17% for population-based studies. For a cut-off of 30 dB HL, the median was 6.6% for the children or school-based studies and 31% for population-based studies. In schools for the deaf, the most common cause of hearing impairment was cryptogenic deafness (50%) followed by infectious causes (43%). In mainstream schools and general population, the most common cause of hearing impairment was middle ear disease (36%), followed by undetermined causes (35%) and cerumen impaction (24%). There are very few population-based studies available to estimate the prevalence of hearing impairment in Africa. Those studies that are available use different cut-offs, making comparison difficult. However, the evidence suggests that the prevalence of hearing impairment is high and that much of it is avoidable or treatable. © 2015 John Wiley & Sons Ltd.
Távora-Vieira, Dayse; Marino, Roberta; Acharya, Aanand; Rajan, Gunesh P
2015-03-01
This study aimed to determine the impact of cochlear implantation on speech understanding in noise, subjective perception of hearing, and tinnitus perception of adult patients with unilateral severe to profound hearing loss and to investigate whether duration of deafness and age at implantation would influence the outcomes. In addition, this article describes the auditory training protocol used for unilaterally deaf patients. This is a prospective study of subjects undergoing cochlear implantation for unilateral deafness with or without associated tinnitus. Speech perception in noise was tested using the Bamford-Kowal-Bench speech-in-noise test presented at 65 dB SPL. The Speech, Spatial, and Qualities of Hearing Scale and the Abbreviated Profile of Hearing Aid Benefit were used to evaluate the subjective perception of hearing with a cochlear implant and quality of life. Tinnitus disturbance was measured using the Tinnitus Reaction Questionnaire. Data were collected before cochlear implantation and 3, 6, 12, and 24 months after implantation. Twenty-eight postlingual unilaterally deaf adults with or without tinnitus were implanted. There was a significant improvement in speech perception in noise across time in all spatial configurations. There was an overall significant improvement on the subjective perception of hearing and quality of life. Tinnitus disturbance reduced significantly across time. Age at implantation and duration of deafness did not influence the outcomes significantly. Cochlear implantation provided significant improvement in speech understanding in challenging situations, subjective perception of hearing performance, and quality of life. Cochlear implantation also resulted in reduced tinnitus disturbance. Age at implantation and duration of deafness did not seem to influence the outcomes.
Khateb, Samer; Zelinger, Lina; Ben-Yosef, Tamar; Crystal-Shalit, Ornit; Gross, Menachem; Banin, Eyal; Sharon, Dror
2012-01-01
We used a combined approach of homozygosity mapping and whole exome sequencing (WES) to search for the genetic cause of autosomal recessive retinitis pigmentosa (arRP) in families of Yemenite Jewish origin. Homozygosity mapping of two arRP Yemenite Jewish families revealed a few homozygous regions. A subsequent WES analysis of the two index cases revealed a shared homozygous novel nucleotide deletion (c.1220delG) leading to a frameshift (p.Gly407Glufs*56) in an alternative exon (#15) of USH1C. Screening of additional Yemenite Jewish patients revealed a total of 16 homozygous RP patients (with a carrier frequency of 0.008 in controls). Funduscopic and electroretinography findings were within the spectrum of typical RP. While other USH1C mutations usually cause Usher type I (including RP, vestibular dysfunction and congenital deafness), audiometric screening of 10 patients who are homozygous for c.1220delG revealed that patients under 40 years of age had normal hearing while older patients showed mild to severe high tone sensorineural hearing loss. This is the first report of a mutation in a known USH1 gene that causes late onset rather than congenital sensorineural hearing loss. The c.1220delG mutation of USH1C accounts for 23% of RP among Yemenite Jewish patients in our cohort. PMID:23251578
Parzefall, Thomas; Lucas, Trevor; Koenighofer, Martin; Ramsebner, Reinhard; Frohne, Alexandra; Czeiger, Shelly; Baumgartner, Wolf-Dieter; Schoefer, Christian; Gstoettner, Wolfgang; Frei, Klemens
2017-04-01
Alterations within a novel putative Exon 1a within the gap junction beta 2 (GJB2) gene may play a role in the development of genetic hearing impairment in Austria. Mutations in the GJB2 gene are the most common cause of hereditary sensorineural deafness. Genome-wide screening for alternative transcriptional start sites in the human genome has revealed the presence of an additional GJB2 exon (E1a). This study tested the hypothesis of whether alternative GJB2 transcription involving E1a may play a role in the development of congenital sensorineural deafness in Austria. GJB2 E1a and flanking regions were sequenced in randomized normal hearing control subjects and three different patient groups with non-syndromic hearing impairment (NSHI), and bioinformatic analysis was performed. Statistical analysis of disease association was carried out using the Cochran-Armitage test for trend. A single change 2410 bp proximal to the translational start site (c.-2410T > C, rs7994748, NM_004004.5:c.-23 + 792T > C) was found to be significantly associated with the common c.35delG GJB2 mutation (p = .009). c.35delG in combination with c.-2410CC occurred at a 6.9-fold increased frequency compared to the control group. Additionally, one patient with idiopathic congenital hearing loss was found to be homozygous c.-2410CC.