Gender- and age-related differences in heart rate dynamics: are women more complex than men?
NASA Technical Reports Server (NTRS)
Ryan, S. M.; Goldberger, A. L.; Pincus, S. M.; Mietus, J.; Lipsitz, L. A.
1994-01-01
OBJECTIVES. This study aimed to quantify the complex dynamics of beat-to-beat sinus rhythm heart rate fluctuations and to determine their differences as a function of gender and age. BACKGROUND. Recently, measures of heart rate variability and the nonlinear "complexity" of heart rate dynamics have been used as indicators of cardiovascular health. Because women have lower cardiovascular risk and greater longevity than men, we postulated that there are important gender-related differences in beat-to-beat heart rate dynamics. METHODS. We analyzed heart rate dynamics during 8-min segments of continuous electrocardiographic recording in healthy young (20 to 39 years old), middle-aged (40 to 64 years old) and elderly (65 to 90 years old) men (n = 40) and women (n = 27) while they performed spontaneous and metronomic (15 breaths/min) breathing. Relatively high (0.15 to 0.40 Hz) and low (0.01 to 0.15 Hz) frequency components of heart rate variability were computed using spectral analysis. The overall "complexity" of each heart rate time series was quantified by its approximate entropy, a measure of regularity derived from nonlinear dynamics ("chaos" theory). RESULTS. Mean heart rate did not differ between the age groups or genders. High frequency heart rate power and the high/low frequency power ratio decreased with age in both men and women (p < 0.05). The high/low frequency power ratio during spontaneous and metronomic breathing was greater in women than men (p < 0.05). Heart rate approximate entropy decreased with age and was higher in women than men (p < 0.05). CONCLUSIONS. High frequency heart rate spectral power (associated with parasympathetic activity) and the overall complexity of heart rate dynamics are higher in women than men. These complementary findings indicate the need to account for gender-as well as age-related differences in heart rate dynamics. Whether these gender differences are related to lower cardiovascular disease risk and greater longevity in women requires further study.
Schonberger, Robert B.; Brandt, Cynthia; Feinleib, Jessica; Dai, Feng; Burg, Matthew M.
2012-01-01
Objectives We analyzed the association between outpatient beta-blocker type and day-of-surgery heart rate in ambulatory surgical patients. We further investigated whether differences in day of surgery heart rate between atenolol and metoprolol could be explained by once-daily versus twice-daily dosing regimens. Design Retrospective observational study. Setting VA Hospital Participants Ambulatory surgical patients on chronic atenolol or metoprolol. Interventions None. Measurements and Main Results Using a propensity-score matched cohort, we compared day of surgery heart rates of patients prescribed atenolol versus metoprolol. We then differentiated between once-daily and twice-daily metoprolol formulations and compared day of surgery heart rates within a general linear model. Day of surgery heart rates in patients prescribed atenolol vs. any metoprolol formulation were slower by a mean of 5.1 beats/min (66.6 vs. 71.7; 95% CI of difference 1.9 to 8.3, p=0.002), a difference that was not observed in preoperative primary care visits. The general linear model demonstrated that patients prescribed atenolol (typically QD dosing) had a mean day of surgery heart rate 5.6 beats/min lower compared to patients prescribed once-daily metoprolol succinate (68.9 vs. 74.5; 95% CI of difference: −8.6 to −2.6, p<0.001) and 3.8 beats/minute lower compared to patients prescribed twice-daily metoprolol tartrate (68.9 vs. 72.7; 95% CI of difference: −6.1 to −1.6, p<0.001). Day of surgery heart rates were similar between different formulations of metoprolol (95% CI of difference: −1.0 to +4.6, p=0.22). Conclusions Atenolol is associated with lower day of surgery heart rate vs. metoprolol. The heart rate difference is specific to the day of surgery and is not explained by once-daily versus twice-daily dosing regimens. PMID:22889605
... Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 Understanding the difference ... your blood moving through your blood vessels, your heart rate is the number of times your heart beats ...
Nomura, Atsushi; Kishimoto, Mitsumasa; Takahashi, Osamu; Deshpande, Gautam A; Yamaguchi, Kenichi; Okada, Masato
2014-05-01
Heart rate-corrected QT interval duration (QTc) has been shown to be related to cardiac autonomic dysfunction in patients with diabetes mellitus, although this association has not been previously described in patients with systemic lupus erythematosus (SLE). We retrospectively reviewed the medical records of 91 SLE patients and 144 non-SLE connective tissue disease patients visiting our clinic from November 2010 to April 2011. We compared ambulatory heart rate identified by pulse measured by automated machine in an outpatient waiting area versus resting heart rate identified on prior screening electrocardiogram. Heart rate differences were analyzed in relation to QTc interval and other characteristics. Ambulatory and resting heart rate differences were larger among SLE patients with QTc prolongation (QTc > 430 ms) than those without QTc prolongation (mean difference, 15.9 vs. 9.6, p = 0.001). In multivariate analysis, differences in heart rate were associated with QTc prolongation (OR 1.10, 95 % CI 1.01-1.21; p = 0.038), independent of age, duration of disease, immunosuppressant use, hydroxychloroquine use, diabetes mellitus, cardiac abnormality, anti-Ro/SS-A antibody positivity, or resting heart rate. Cardiac autonomic dysfunction is a common manifestation of SLE and may be related to QTc prolongation.
Cardiovascular Fitness and Maximal Heart Rate Differences Among Three Ethnic Groups.
ERIC Educational Resources Information Center
Farrell, S. W.
1988-01-01
Examination of differences in maximal heart rate and treadmill time among three ethnic groups revealed no significant age-adjusted differences among white, black, and Mexican-American males, and suggested that black females' lower maximal heart rate may be explained by their lower cardiovascular fitness level when compared to those of other…
Heart rate measurement as a tool to quantify sedentary behavior.
Åkerberg, Anna; Koshmak, Gregory; Johansson, Anders; Lindén, Maria
2015-01-01
Sedentary work is very common today. The aim of this pilot study was to attempt to differentiate between typical work situations and to investigate the possibility to break sedentary behavior, based on physiological measurement among office workers. Ten test persons used one heart rate based activity monitor (Linkura), one pulse oximeter device (Wrist) and one movement based activity wristband (Fitbit Flex), in different working situations. The results showed that both heart rate devices, Linkura and Wrist, were able to detect differences in heart rate between the different working situations (resting, sitting, standing, slow walk and medium fast walk). The movement based device, Fitbit Flex, was only able to separate differences in steps between slow walk and medium fast walk. It can be concluded that heart rate measurement is a promising tool for quantifying and separating different working situations, such as sitting, standing and walking.
Hamer, Mark; Boutcher, Yati N; Boutcher, Stephen H
2005-12-01
This study examined differentiated rating of perceived exertion (RPE), heart rate, and heart-rate variability during light cycle ergometry exercise at two different pedal rates. 30 healthy men (22.6 +/- 0.9 yr.) were recruited from a student population and completed a continuous 20-min. cycle ergometry exercise protocol, consisting of a 4-min. warm-up (60 rev./min., 30 Watts), followed by four bouts of 4 min. at different combinations of pedal rate (40 or 80 rev./min.) and power output (40 or 80 Watts). The order of the four combinations was counterbalanced across participants. Heart rate was measured using a polar heart-rate monitor, and parasympathetic balance was assessed through time series analysis of heart-rate variability. Measures were compared using a 2 (pedal rate) x 2 (power output) repeated-measures analysis of variance. RPE was significantly greater (p<.05) at 80 versus 40 rev./min. at 40 W. For both power outputs heart rate was significantly increased, and the high frequency component of heart-rate variability was significantly reduced at 80 compared with 40 rev./min. These findings indicate the RPE was greater at higher than at lower pedalling rates for a light absolute power output which contrasts with previous findings based on use of higher power output. Also, pedal rate had a significant effect on heart rate and heart-rate variability at constant power output.
The predictive value of resting heart rate following osmotherapy in brain injury: back to basics.
Hasanpour Mir, Mahsa; Yousefshahi, Fardin; Abdollahi, Mohammad; Ahmadi, Arezoo; Nadjafi, Atabak; Mojtahedzadeh, Mojtaba
2012-12-30
The importance of resting heart rate as a prognostic factor was described in several studies. An elevated heart rate is an independent risk factor for adverse cardiovascular events and total mortality in patients with coronary artery disease, chronic heart failure, and the general population. Also heart rate is elevated in the Multi Organ Dysfunction Syndrome (MODS) and the mortality due to MODS is highly correlated with inadequate sinus tachycardia.To evaluate the value of resting heart rate in predicting mortality in patients with traumatic brain injury along scoring systems like Acute Physiology and Chronic Health Evaluation(APACHE II), Sequential Organ Failure Assessment (SOFA) and Glasgow Coma Score (GCS). By analyzing data which was collected from an open labeled randomized clinical trial that compared the different means of osmotherapy (mannitol vs bolus or infusion hypertonic saline), heart rate, GCS, APACHE II and SOFA score were measured at baseline and daily for 7 days up to 60 days and the relationship between elevated heart rate and mortality during the first 7 days and 60th day were assessed. After adjustments for confounding factors, although there was no difference in mean heart rate between either groups of alive and expired patients, however, we have found a relative correlation between 60th day mortality rate and resting heart rate (P=0.07). Heart rate can be a prognostic factor for estimating mortality rate in brain injury patients along with APACHE II and SOFA scores in patients with brain injury.
Influence of ECG sampling rate in fetal heart rate variability analysis.
De Jonckheere, J; Garabedian, C; Charlier, P; Champion, C; Servan-Schreiber, E; Storme, L; Debarge, V; Jeanne, M; Logier, R
2017-07-01
Fetal hypoxia results in a fetal blood acidosis (pH<;7.10). In such a situation, the fetus develops several adaptation mechanisms regulated by the autonomic nervous system. Many studies demonstrated significant changes in heart rate variability in hypoxic fetuses. So, fetal heart rate variability analysis could be of precious help for fetal hypoxia prediction. Commonly used fetal heart rate variability analysis methods have been shown to be sensitive to the ECG signal sampling rate. Indeed, a low sampling rate could induce variability in the heart beat detection which will alter the heart rate variability estimation. In this paper, we introduce an original fetal heart rate variability analysis method. We hypothesize that this method will be less sensitive to ECG sampling frequency changes than common heart rate variability analysis methods. We then compared the results of this new heart rate variability analysis method with two different sampling frequencies (250-1000 Hz).
Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan
2013-01-01
This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels.
A randomised, simulated study assessing auscultation of heart rate at birth.
Voogdt, Kevin G J A; Morrison, Allison C; Wood, Fiona E; van Elburg, Ruurd M; Wyllie, Jonathan P
2010-08-01
Heart rate is a primary clinical indicator directing newborn resuscitation. The time taken to assess the heart rate by auscultation in relation to accuracy during newborn resuscitation is not known. To assess both the accuracy and time taken to assess heart rate by stethoscope in simulated resuscitation scenarios. The VitalSim((c)) manikin (Laerdal Medical, Stavanger, Norway) was used in this randomised, single blind study. Four heart rate settings (0, 40, 80, 120 beats per minute (bpm)) were randomly assigned. Participants assessed them by auscultation in three different scenarios. The first scenario was to assess the actual heart rate at birth. In the second scenario, heart rate was assessed during ventilation and assigned to standard ranges (<60, 60-100, >100bpm). In the third scenario, heart rate was assessed after three cycles of compressions and ventilation and assigned to standard ranges. In total 61 midwives, nurses and doctors performed 183 assessments. Mean time to estimate heart rate for scenarios 1, 2 and 3 was: 17.0, 9.8 and 7.8s respectively. Heart rate assessments were inaccurate in 31% (scenario 1), 28% (scenarios 2) and 26% (scenario 3). There was a trend for assessors who were accurate to be quicker and this achieved significance in scenario 2 (p<0.02). Inaccurate assessment would have made a difference to management in 28% of all cases. Mean time to estimate heart rate for the scenarios varied between 7.8 and 17.0s. Twenty-eight percent of all heart rate assessments would have prompted incorrect management during resuscitation or stabilization. Of incorrect assessments, 73% were overestimations. Further research is required to develop a rapid and accurate method for determining heart rate during newborn resuscitation. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Monfredi, Oliver; Lyashkov, Alexey E; Johnsen, Anne-Berit; Inada, Shin; Schneider, Heiko; Wang, Ruoxi; Nirmalan, Mahesh; Wisloff, Ulrik; Maltsev, Victor A; Lakatta, Edward G; Zhang, Henggui; Boyett, Mark R
2014-01-01
Heart rate variability (beat-to-beat changes in the RR interval) has attracted considerable attention over the last 30+ years (PubMed currently lists >17,000 publications). Clinically, a decrease in heart rate variability is correlated to higher morbidity and mortality in diverse conditions, from heart disease to foetal distress. It is usually attributed to fluctuation in cardiac autonomic nerve activity. We calculated heart rate variability parameters from a variety of cardiac preparations (including humans, living animals, Langendorff-perfused heart and single sinoatrial nodal cell) in diverse species, combining this with data from previously published papers. We show that regardless of conditions, there is a universal exponential decay-like relationship between heart rate variability and heart rate. Using two biophysical models, we develop a theory for this, and confirm that heart rate variability is primarily dependent on heart rate and cannot be used in any simple way to assess autonomic nerve activity to the heart. We suggest that the correlation between a change in heart rate variability and altered morbidity and mortality is substantially attributable to the concurrent change in heart rate. This calls for re-evaluation of the findings from many papers that have not adjusted properly or at all for heart rate differences when comparing heart rate variability in multiple circumstances. PMID:25225208
Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography
Penzel, Thomas; Kantelhardt, Jan W.; Bartsch, Ronny P.; Riedl, Maik; Kraemer, Jan F.; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph
2016-01-01
The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave). PMID:27826247
Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.
Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph
2016-01-01
The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).
Carvalho, Vitor Oliveira; Guimarães, Guilherme Veiga; Ciolac, Emmanuel Gomes; Bocchi, Edimar Alcides
2008-01-01
BACKGROUND Calculating the maximum heart rate for age is one method to characterize the maximum effort of an individual. Although this method is commonly used, little is known about heart rate dynamics in optimized beta-blocked heart failure patients. AIM The aim of this study was to evaluate heart rate dynamics (basal, peak and % heart rate increase) in optimized beta-blocked heart failure patients compared to sedentary, normal individuals (controls) during a treadmill cardiopulmonary exercise test. METHODS Twenty-five heart failure patients (49±11 years, 76% male), with an average LVEF of 30±7%, and fourteen controls were included in the study. Patients with atrial fibrillation, a pacemaker or noncardiovascular functional limitations or whose drug therapy was not optimized were excluded. Optimization was considered to be 50 mg/day or more of carvedilol, with a basal heart rate between 50 to 60 bpm that was maintained for 3 months. RESULTS Basal heart rate was lower in heart failure patients (57±3 bpm) compared to controls (89±14 bpm; p<0.0001). Similarly, the peak heart rate (% maximum predicted for age) was lower in HF patients (65.4±11.1%) compared to controls (98.6±2.2; p<0.0001). Maximum respiratory exchange ratio did not differ between the groups (1.2±0.5 for controls and 1.15±1 for heart failure patients; p=0.42). All controls reached the maximum heart rate for their age, while no patients in the heart failure group reached the maximum. Moreover, the % increase of heart rate from rest to peak exercise between heart failure (48±9%) and control (53±8%) was not different (p=0.157). CONCLUSION No patient in the heart failure group reached the maximum heart rate for their age during a treadmill cardiopulmonary exercise test, despite the fact that the percentage increase of heart rate was similar to sedentary normal subjects. A heart rate increase in optimized beta-blocked heart failure patients during cardiopulmonary exercise test over 65% of the maximum age-adjusted value should be considered an effort near the maximum. This information may be useful in rehabilitation programs and ischemic tests, although further studies are required. PMID:18719758
Heart Rate, Life Expectancy and the Cardiovascular System: Therapeutic Considerations.
Boudoulas, Konstantinos Dean; Borer, Jeffrey S; Boudoulas, Harisios
2015-01-01
It has long been known that life span is inversely related to resting heart rate in most organisms. This association between heart rate and survival has been attributed to the metabolic rate, which is greater in smaller animals and is directly associated with heart rate. Studies have shown that heart rate is related to survival in apparently healthy individuals and in patients with different underlying cardiovascular diseases. A decrease in heart rate due to therapeutic interventions may result in an increase in survival. However, there are many factors regulating heart rate, and it is quite plausible that these may independently affect life expectancy. Nonetheless, a fast heart rate itself affects the cardiovascular system in multiple ways (it increases ventricular work, myocardial oxygen consumption, endothelial stress, aortic/arterial stiffness, decreases myocardial oxygen supply, other) which, in turn, may affect survival. In this brief review, the effects of heart rate on the heart, arterial system and survival will be discussed. © 2015 S. Karger AG, Basel.
The predictive value of resting heart rate following osmotherapy in brain injury: back to basics
2012-01-01
Background The importance of resting heart rate as a prognostic factor was described in several studies. An elevated heart rate is an independent risk factor for adverse cardiovascular events and total mortality in patients with coronary artery disease, chronic heart failure, and the general population. Also heart rate is elevated in the Multi Organ Dysfunction Syndrome (MODS) and the mortality due to MODS is highly correlated with inadequate sinus tachycardia. To evaluate the value of resting heart rate in predicting mortality in patients with traumatic brain injury along scoring systems like Acute Physiology and Chronic Health Evaluation(APACHE II), Sequential Organ Failure Assessment (SOFA) and Glasgow Coma Score (GCS). Method By analyzing data which was collected from an open labeled randomized clinical trial that compared the different means of osmotherapy (mannitol vs bolus or infusion hypertonic saline), heart rate, GCS, APACHE II and SOFA score were measured at baseline and daily for 7 days up to 60 days and the relationship between elevated heart rate and mortality during the first 7 days and 60th day were assessed. Results After adjustments for confounding factors, although there was no difference in mean heart rate between either groups of alive and expired patients, however, we have found a relative correlation between 60th day mortality rate and resting heart rate (P=0.07). Conclusion Heart rate can be a prognostic factor for estimating mortality rate in brain injury patients along with APACHE II and SOFA scores in patients with brain injury. PMID:23351393
A new method to measure heart rate with EMFi and PVDF materials.
Kärki, S; Lekkala, J
2009-01-01
In this paper we propose a new simple method to measure the heart rate of a person sitting on a chair or lying in a bed. The heart rate is measured with a thin sensor pad consisting of separate electromechanical film (EMFi) and polyvinylidenefluoride (PVDF) transducers located beneath the leg of chair or bed. This study aims to evaluate the operation of the sensor system with measurements, and also to compare the results provided by the two transducer materials. Based on the results obtained here, the heart rates measured with the transducers mainly corresponded to the values of reference ECG signal. Some minor differences between the heart rate values of PVDF and EMFi appeared, especially in supine position, possible due to the material sensitivities to different force directions. However, to conclude, both materials seem to be convenient for this kind of measurement of heart rate.
Middle School Student's Heart Rates during Different Curricular Activities in Physical Education
ERIC Educational Resources Information Center
Gao, Zan; Hannon, James C.; Carson, Russell L.
2009-01-01
The purpose of this study was to determine if students' heart rate outcomes in physical education varied as a function of activity and grade. A total of 146 sixth to eighth graders participated in different activities (i.e., walking/jogging, line dancing, soccer, and catch ball). Their average heart rate (AHR) and percentage of time in and above…
Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan
2013-01-01
Background and Objectives. This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. Materials and Methods. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. Results. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). Conclusion. No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels. PMID:23781252
Osadchii, Oleg E
2014-12-01
In the clinical setting, patients with slower resting heart rate are less prone to cardiovascular death compared with those with elevated heart rate. However, electrophysiological adaptations associated with reduced cardiac rhythm have not been thoroughly explored. In this study, relationships between intrinsic heart rate and arrhythmic susceptibility were examined by assessments of action potential duration (APD) rate adaptation and inducibility of repolarization alternans in sinoatrial node (SAN)-driven and atrioventricular (AV)-blocked guinea-pig hearts perfused with Langendorff apparatus. Electrocardiograms, epicardial monophasic action potentials, and effective refractory periods (ERP) were assessed in normokalemic and hypokalemic conditions. Slower basal heart rate in AV-blocked hearts was associated with prolonged ventricular repolarization during spontaneous beating, and with attenuated APD shortening at increased cardiac activation rates during dynamic pacing, when compared with SAN-driven hearts. During hypokalemic perfusion, the inducibility of repolarization alternans and tachyarrhythmia by rapid pacing was found to be lower in AV-blocked hearts. This difference was ascribed to prolonged ERP in the setting of reduced basal heart rate, which prevented ventricular capture at critically short pacing intervals required to induce arrhythmia. Reduced basal heart rate is associated with electrophysiological changes that prevent electrical instability upon an abrupt cardiac acceleration.
[Heart failure mortality in Spain: is there an andalusian paradox?].
Jiménez-Navarro, M; Gómez-Doblas, J; Molero, E; Galván, E de Teresa
2006-06-01
Congestive heart failure has a high mortality, as reflected in different clinical trials and observational studies. Spain, as other countries around the Mediterranean basin, have a relatively low rate of coronary deaths, attributed to the so-called Mediterranean lifestyle. Andalusia, in the southern most part of Spain, constitutes the paradigm of Mediterranean lifestyle. However, different reports show that the prevalence of ischemic heart disease is higher in Andalusia than in other zones of Spain. Thus the mortality rate due to heart failure in Spain in the year 2000 per 100,000 inhabitants was 27.3 in men and 28.88 in women and each one of the eight Andalusia provinces had greater rates than the national mean in both men and woman. Even in countries with a relatively low prevalence of coronary heart disease as is the case in Spain, heart failure mortality seems to be parallel to local differences in IHD prevalence.
Ventilatory control of heart rate during inhalation of 5% CO2 and types of panic attacks.
Ley, R
1991-09-01
Differences in the magnitude of increases in heart rate during prolonged inhalation of 5% CO2 range from a mean of 25 b/min for a group of eight panic-disorder patients who panicked (Woods, Charney, Goodman, & Heninger, 1988. Archives of General Psychiatry, 45, 43-52) to zero b/min for 16 patients, eight of whom panicked (Craske & Barlow, 1990. Journal of Abnormal Psychology, 99, 302-307). What accounts for this disparity? The present paper describes how heart rate can be increased by means of voluntary overbreathing during prolonged inhalation of 5% CO2 in air. This suggests that differences in the degree of overbreathing may explain differences in the magnitude of increases in heart rate during inhalation of 5% CO2. An explanation is also offered for the curious finding that some patients experience "panic attacks" with zero increase in heart rate. Evidence suggests that this is likely to happen in cognitively based panic attacks, in contrast to hyperventilatory attacks or anticipatory attacks.
Robust sensor fusion of unobtrusively measured heart rate.
Wartzek, Tobias; Brüser, Christoph; Walter, Marian; Leonhardt, Steffen
2014-03-01
Contactless vital sign measurement technologies often have the drawback of severe motion artifacts and periods in which no signal is available. However, using several identical or physically different sensors, redundancy can be used to decrease the error in noncontact heart rate estimation, while increasing the time period during which reliable data are available. In this paper, we show for the first time two major results in case of contactless heart rate measurements deduced from a capacitive ECG and optical pulse signals. First, an artifact detection is an essential preprocessing step to allow a reliable fusion. Second, the robust but computationally efficient median already provides good results; however, using a Bayesian approach, and a short time estimation of the variance, best results in terms of difference to reference heart rate and temporal coverage can be achieved. In this paper, six sensor signals were used and coverage increased from 0-90% to 80-94%, while the difference between the estimated heart rate and the gold standard was less than ±2 BPM.
Wrzus, Cornelia; Müller, Viktor; Wagner, Gert G; Lindenberger, Ulman; Riediger, Michaela
2014-09-01
We propose that a comprehensive understanding of age differences in affective responses to emotional situations requires the distinction of 2 components of affect dynamics: reactivity, the deviation from a person's baseline, and recovery, the return to this baseline. The present study demonstrates the utility of this approach with a focus on age differences in responses of negative affect and heart rate to an unpleasant emotional situation in 92 participants aged 14 to 83. The emotional situation was elicited with a social-cognitive stress task. Participants' negative affect and heart rate were measured throughout the task. Results showed that heart rate reactivity decreased, but heart rate recovery time increased, with age. In contrast, no significant age differences were observed in either reactivity or recovery for negative affect. These findings confirm that reactivity to, and recovery from, unpleasant emotional situations are distinct components of affect dynamics. They underscore the multidirectional nature of age differences in affective processes. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Heart rate reduction and longevity in mice.
Gent, Sabine; Kleinbongard, Petra; Dammann, Philip; Neuhäuser, Markus; Heusch, Gerd
2015-03-01
Heart rate correlates inversely with life span across all species, including humans. In patients with cardiovascular disease, higher heart rate is associated with increased mortality, and such patients benefit from pharmacological heart rate reduction. However, cause-and-effect relationships between heart rate and longevity, notably in healthy individuals, are not established. We therefore prospectively studied the effects of a life-long pharmacological heart rate reduction on longevity in mice. We hypothesized, that the total number of cardiac cycles is constant, and that a 15% heart rate reduction might translate into a 15% increase in life span. C57BL6/J mice received either placebo or ivabradine at a dose of 50 mg/kg/day in drinking water from 12 weeks to death. Heart rate and body weight were monitored. Autopsy was performed on all non-autolytic cadavers, and parenchymal organs were evaluated macroscopically. Ivabradine reduced heart rate by 14% (median, interquartile range 12-15%) throughout life, and median life span was increased by 6.2% (p = 0.01). Body weight and macroscopic findings were not different between placebo and ivabradine. Life span was not increased to the same extent as heart rate was reduced, but nevertheless significantly prolonged by 6.2%.
Mulder, Bart A; Damman, Kevin; Van Veldhuisen, Dirk J; Van Gelder, Isabelle C; Rienstra, Michiel
2017-09-01
Heart rate has been associated with prognosis in patients with heart failure with reduced ejection fraction (HFREF) and sinus rhythm; whether this also holds true in patients with atrial fibrillation (AF) is unknown. To evaluate cardiac rhythm and baseline heart rate and the influence of outcome in patients with HFREF enrolled in the Cardiac Insufficiency Bisoprolol Study II. In total, 2539 patients were stratified according to their baseline heart rhythm (AF or sinus rhythm) and into quartiles of heart rate (≤70 bpm, 71-78 bpm, 79-90 bpm, and >90 bpm). The primary outcome was all-cause mortality. Mean follow-up was 1.3 years. Mean age was 61 years, mean left ventricular ejection fraction was 28%, and 80% were male. A total of 521 (21%) patients had AF at baseline. The risk associated with all-cause mortality for each 5 bpm increase in heart rate in patients with sinus rhythm (hazard ratio [HR]: 1.06, 95% confidence interval [CI]: 1.01-1.11, P = 0.012) was significantly different from those with AF (HR: 1.00, 95% CI: 0.94-1.07, P = 0.90, P for interaction = 0.041). The risk associated with higher heart rate in sinus rhythm was primarily attributable to excess risk in the highest quartile (HR: 1.64, 95% CI: 1.18-2.30, P = 0.003). Allocation to bisoprolol did not modify the interaction between heart rate, rhythm and outcome. In HFREF patients with AF, a higher heart rate is not associated with increased event rates in contrast to HFREF patients with sinus rhythm. © 2017 Wiley Periodicals, Inc.
Prostaglandins are important in thermoregulation of a reptile (Pogona vitticeps).
Seebacher, Frank; Franklin, Craig E
2003-01-01
The effectiveness of behavioural thermoregulation in reptiles is amplified by cardiovascular responses, particularly by differential rates of heart beat in response to heating and cooling (heart-rate hysteresis). Heart-rate hysteresis is ecologically important in most lineages of ectothermic reptile, and we demonstrate that heart-rate hysteresis in the lizard Pogona vitticeps is mediated by prostaglandins. In a control treatment (administration of saline), heart rates during heating were significantly faster than during cooling at any given body temperature. When cyclooxygenase 1 and 2 enzymes were inhibited, heart rates during heating were not significantly different from those during cooling. Administration of agonists showed that thromboxane B(2) did not have a significant effect on heart rate, but prostacyclin and prostaglandin F(2alpha) caused a significant increase (3.5 and 13.6 beats min(-1), respectively) in heart rate compared with control treatments. We speculate that heart-rate hysteresis evolved as a thermoregulatory mechanism that may ultimately be controlled by neurally induced stimulation of nitric oxide production, or maybe via photolytically induced production of vitamin D. PMID:12952634
Prostaglandins are important in thermoregulation of a reptile (Pogona vitticeps).
Seebacher, Frank; Franklin, Craig E
2003-08-07
The effectiveness of behavioural thermoregulation in reptiles is amplified by cardiovascular responses, particularly by differential rates of heart beat in response to heating and cooling (heart-rate hysteresis). Heart-rate hysteresis is ecologically important in most lineages of ectothermic reptile, and we demonstrate that heart-rate hysteresis in the lizard Pogona vitticeps is mediated by prostaglandins. In a control treatment (administration of saline), heart rates during heating were significantly faster than during cooling at any given body temperature. When cyclooxygenase 1 and 2 enzymes were inhibited, heart rates during heating were not significantly different from those during cooling. Administration of agonists showed that thromboxane B(2) did not have a significant effect on heart rate, but prostacyclin and prostaglandin F(2alpha) caused a significant increase (3.5 and 13.6 beats min(-1), respectively) in heart rate compared with control treatments. We speculate that heart-rate hysteresis evolved as a thermoregulatory mechanism that may ultimately be controlled by neurally induced stimulation of nitric oxide production, or maybe via photolytically induced production of vitamin D.
Heart Rate and Energy Expenditure in Division I Field Hockey Players During Competitive Play.
Sell, Katie M; Ledesma, Allison B
2016-08-01
Sell, KM and Ledesma, AB. Heart rate and energy expenditure in Division I field hockey players during competitive play. J Strength Cond Res 30(8): 2122-2128, 2016-The purpose of this study was to quantify energy expenditure and heart rate data for Division I female field hockey players during competitive play. Ten female Division I collegiate field hockey athletes (19.8 ± 1.6 years; 166.4 ± 6.1 cm; 58.2 ± 5.3 kg) completed the Yo-Yo intermittent endurance test to determine maximal heart rate. One week later, all subjects wore a heart rate monitor during a series of 3 matches in an off-season competition. Average heart rate (AvHR), average percentage of maximal heart rate (AvHR%), peak exercise heart rate (PExHR), and percentage of maximal heart rate (PExHR%), time spent in each of the predetermined heart rate zones, and caloric expenditure per minute of exercise (kcalM) were determined for all players. Differences between positions (backs, midfielders, and forwards) were assessed. No significant differences in AvHR, AvHR%, PExHR, PExHR%, and %TM were observed between playing positions. The AvHR% and PExHR% for each position fell into zones 4 (77-93% HRmax) and 5 (>93% HRmax), respectively, and significantly more time was spent in zone 4 compared with zones 1, 2, 3, and 5 across all players (p ≤ 0.05). The kcalM reflected very heavy intensity exercise. The results of this study will contribute toward understanding the sport-specific physiological demands of women's field hockey and has specific implications for the duration and schedule of training regimens.
Davidovic, Goran; Iric-Cupic, Violeta; Milanov, Srdjan; Dimitijevic, Aleksandra; Petrovic-Janicijevic, Mirjana
2013-01-01
Many prospective studies established association between high heart rate and increased cardiovascular morbidity and mortality, independently of other risk factors. Heart rate over 80 beats per minute more often leads to atherosclerotic plaque disruption, the main step in developing acute coronary syndrome. Purpose was to investigate the incidence of higher heart rate levels in patients with anterior wall acute myocardial infarction with ST-segment elevation and the influence of heart rate on mortality. Research included 140 patients with anterior wall acute myocardial infarction with ST-segment elevation treated in Coronary Unit, Clinical Center Kragujevac in the period from January 2001-June 2006. Heart rate was calculated as the mean value of baseline and heart rate in the first 30 minutes after admission. Other risk factors were also followed to determine their connection with elevated heart rate. Results showed that the majority of patients survived (over 70%). In a total number of patients, more than 75% had a heart rate levels greater than 80 beats per minute. There was a significant difference in heart rate on addmision between survivors and patients who died, with a greater levels in patients with fatal outcome. Both, univariate and multivariate regression analysis singled out heart rate greater than 80 beats per minute as independent mortality predictor in these patients. Heart rate greater than 80 beats per minute is a major, independent risk factor for morbidity and important predictor of mortality in patients with acute myocardial infarction. PMID:23991346
Oh, Myung Ok; Kim, Young Jeoum; Baek, Cho Hee; Kim, Ju Hee; Park, No Mi; Yu, Mi Jeong; Song, Han Sol
2016-06-01
The purpose of this cross-over experimental study was to examine effects of music intervention on maternal anxiety, fetal heart rate pattern and testing time during non-stress tests (NST) for antenatal fetal assessment. Sixty pregnant women within 28 to 40 gestational weeks were randomly assigned to either the experimental group (n=30) or control group (n=30). Music intervention was provided to pregnant women in the experimental group during NST. Degree of maternal anxiety and fetal heart rate pattern were our primary outcomes. State-trait anxiety inventory, blood pressure, pulse rate, and changes in peripheral skin temperature were assessed to determine the degree of maternal anxiety. Baseline fetal heart rate, frequency of acceleration in fetal heart rate, fetal movement test and testing time for reactive NST were assessed to measure the fetal heart rate pattern. The experimental group showed significantly lower scores in state anxiety than the control group. There were no significant differences in systolic blood pressure and pulse rate between the two groups. Baseline fetal heart rate was significantly lower in the experimental group than in the control group. Frequency of acceleration in fetal heart rate was significantly increased in the experimental group compared to the control group. There were no significant differences in fetal movement and testing time for reactive NST between the two groups. Present results suggest that music intervention could be an effective nursing intervention for alel viating anxiety during non-stress test.
Isoflurane increases cardiorespiratory coordination in rats
NASA Astrophysics Data System (ADS)
Kabir, Muammar M.; Beig, Mirza I.; Nalivaiko, Eugene; Abbott, Derek; Baumert, Mathias
2008-12-01
Anesthetics such as isoflurane adversely affect heart rate. In this study we analysed the interaction between heart rhythm and respiration at different concentrations of isoflurane and ventilation rates. In two rats, the electrocardiogram (ECG) and respiratory signals were recorded under the influence of isoflurane. For the assessment of cardiorespiratory coordination, we analysed the phase locking between heart rate, computed from the R-R intervals of body surface ECG, and respiratory rate, computed from impedance changes, using Hilbert transform. The changes in heart rate, percentage of synchronization and duration of synchronized epochs at different isoflurane concentrations and ventilation rates were assessed using linear regression model. From this study it appears that the amount of phase locking between cardiac and respiratory rates increases with the increase in concentration of isoflurane. Heart rate and duration of synchronized epochs increased significantly with the increase in the level of isoflurane concentration while respiratory rate was not significantly affected. Cardiorespiratory coordination also showed a considerable increase at the ventilation rates of 50- 55 cpm in both the rats, suggesting that the phase-locking between the cardiac and respiratory oscillators can be increased by breathing at a particular respiratory frequency.
NASA Technical Reports Server (NTRS)
Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.
1993-01-01
OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.
Ambulatory blood pressure and heart rate during shuttle flight, entry and landing
NASA Technical Reports Server (NTRS)
Thornton, W.; Moore, T. P.; Uri, J.
1993-01-01
Ambulatory blood pressures (BP) and heart rates (HR) were recorded on a series of early Shuttle flights during preflight and pre-entry, entry, landing and egress. There were no significant differences between flight and preflight values during routine activity. Systolic blood pressure was slightly elevated in the deorbit period and systolic and diastolic blood pressure and heart rates were all elevated with onset of gravitoinertial loads and remained so through egress. Two of seven subjects had orthostatic problems in egress but their data did not show significant differences from others except in heart rate. Comparison of this data to that from recent studies show even larger increase in HR/BP values during current deorbit and entry phases which is consistent with increased heat and weight loads imposed by added survival gear. Both value and limitations of ambulatory heart rate/blood pressure data in this situation are demonstrated.
Tőzsér, János; Szenci, Ottó; Póti, Péter; Pajor, Ferenc
2015-01-01
From the 1990s, extensive research was started on the physiological aspects of individual traits in animals. Previous research has established two extreme (proactive and reactive) coping styles in several animal species, but the means of reactivity with the autonomic nervous system (ANS) activity has not yet been investigated in cattle. The aim of this study was the characterization of cardiac autonomic activity under different conditions in cows with different individual characteristics. For this purpose, we investigated heart rate and ANS-related heart rate variability (HRV) parameters of dairy cows (N = 282) on smaller- and larger-scale farms grouped by (1) temperament and (2) behavioural reactivity to humans (BRH). Animals with high BRH scores were defined as impulsive, while animals with low BRH scores were defined as reserved. Cardiac parameters were calculated for undisturbed lying (baseline) and for milking bouts, the latter with the presence of an unfamiliar person (stressful situation). Sympathetic tone was higher, while vagal activity was lower in temperamental cows than in calm animals during rest both on smaller- and larger-scale farms. During milking, HRV parameters were indicative of a higher sympathetic and a lower vagal activity of temperamental cows as compared to calm ones in farms of both sizes. Basal heart rate did not differ between BRH groups either on smaller- or larger-scale farms. Differences between basal ANS activity of impulsive and reserved cows reflected a higher resting vagal and lower sympathetic activity of reserved animals compared to impulsive ones both on smaller- and larger-scale farms. There was no difference either in heart rate or in HRV parameters between groups during milking neither in smaller- nor in larger-scale farms. These two groupings allowed to draw possible parallels between personality and cardiac autonomic activity during both rest and milking in dairy cows. Heart rate and HRV seem to be useful for characterisation of physiological differences related to temperament and BRH. PMID:26291979
Koschate, Jessica; Drescher, Uwe; Baum, Klaus; Brinkmann, Christian; Schiffer, Thorsten; Latsch, Joachim; Brixius, Klara; Hoffmann, Uwe
2017-05-01
The aim of this pilot study was to investigate whether there are differences in heart rate and oxygen uptake kinetics in type 2 diabetes patients, considering their cardiovascular medication. It was hypothesized that cardiovascular medication would affect heart rate and oxygen uptake kinetics and that this could be detected using a standardized exercise test. 18 subjects were tested for maximal oxygen uptake. Kinetics were measured in a single test session with standardized, randomized moderate-intensity work rate changes. Time series analysis was used to estimate kinetics. Greater maxima in cross-correlation functions indicate faster kinetics. 6 patients did not take any cardiovascular medication, 6 subjects took peripherally acting medication and 6 patients were treated with centrally acting medication. Maximum oxygen uptake was not significantly different between groups. Significant main effects were identified regarding differences in muscular oxygen uptake kinetics and heart rate kinetics. Muscular oxygen uptake kinetics were significantly faster than heart rate kinetics in the group with no cardiovascular medication (maximum in cross-correlation function of muscular oxygen uptake vs. heart rate; 0.32±0.08 vs. 0.25±0.06; p=0.001) and in the group taking peripherally acting medication (0.34±0.05 vs. 0.28±0.05; p=0.009) but not in the patients taking centrally acting medication (0.28±0.05 vs. 0.30±0.07; n.s.). It can be concluded that regulatory processes for the achievement of a similar maximal oxygen uptake are different between the groups. The used standardized test provided plausible results for heart rate and oxygen uptake kinetics in a single measurement session in this patient group. © Georg Thieme Verlag KG Stuttgart · New York.
Davidovic, Goran; Iric-Cupic, Violeta; Milanov, Srdjan
2013-01-01
Acute myocardial infarction as a form of coronary heart disease is characterized by permanent damage/loss of anatomical and functional cardiac tissue. Diagnosis of STEMI includes data on anginal pain and persistent ST-segment elavation. According to the numerous epidemiological studies, arterial blood pressure and heart rate are offten increased especially during the first hours of pain due to domination of sympathetic response. We wanted to investigate the associated influence of heart rate greater than 80 beats per minute and hypertension on the mortality in patients with anterior wall STEMI. Research included 140 patients treated in Coronary Unit, Clinical Center Kragujevac form January 2001 to June 2006. Heart rate was calculated as the mean value of baseline and heart rate in the first 30 minutes after admission, recorded on monitor and electrocardiogram. Data for history of hypertension were collected and blood pressure levels were measured in a lying position after 5 minutes of rest, and classified according to the VII JNC recommendations as confirmation of hypertension. Collected data were analyzed in SPSS 13.0 for Windows. Heart rate greater than 80 bpm influences the hospital mortality. Systolic blood pressure levels were higher in the survivors, while for the diastolic there was no difference. History of hypertension was singled out as a significant predictor of mortality without difference between the respondents with heart rate greater and lower than 80 bpm in the survivors and fatal. Increased heart rate and hypertension at admission are significant predictors of mortality in patients with anterior wall STEMI. PMID:23724155
Heart Rates of Elementary Physical Education Students during the Dancing Classrooms Program
ERIC Educational Resources Information Center
Nelson, Larry; Evans, Melissa; Guess, Wendy; Morris, Mary; Olson, Terry; Buckwalter, John
2011-01-01
We examined how different types of dance activities, along with their duration, influenced heart rate responses among fifth-grade physical education students (N = 96) who participated in the Dancing Classrooms program. Results indicated that the overall Dancing Classrooms program elicits a moderate cardiovascular heart rate response (M = 124.4…
Luttkus, A K; Friedmann, W; Homm-Luttkus, C; Dudenhausen, J W
1998-03-01
The purpose of this study was the correlation of fetal oxygen saturation values to various fetal heart rate patterns, as well as to oxygen saturation values obtained by fetal blood analysis. These objectives need to be evaluated from the perspective that two generations of fetal oxisensors have been used. Two different oxisensor systems (FS10: 660+890 nm and FS14: 735+890 nm) and a blinded pulse oximeter (type N400, Nellcor Puritan Bennett) were utilized to monitor 112 fetuses. All data, including oxygen saturation, fetal heart rate patterns, signal and contact quality were stored on a personal computer and evaluated after delivery. The following median fetal oxygen saturation values were obtained: during reassuring fetal heart rate sequences 54% with the oxisensor FS10 and 48% with the newer FS14 oxisensor, during intervals of variable decelerations 43% with the FS10 oxisensor and 40% with the FS14 oxisensor. These differences between values obtained during normal and abnormal fetal heart rate patterns are significant. Due to non-reassuring fetal heart rate patterns 81 fetal blood analyses were performed. The values of pulse oximetry were 9% higher (6% for the FS14) than those of spectrophotometry. Correlation of both methods was r=0.66 (0.74 for the FS14). In combination with fetal heart rate monitoring, fetal pulse oximetry promises a better differentiation between low and high risk heart rate patterns. Oxygen saturation values from intermittent fetal blood sampling reassure the clinician concerning the accuracy of this new method of intrapartum fetal surveillance and underline the increased quality of the new generation of oxisensor using light of a wavelength of 735 and 890 nm.
Using complexity metrics with R-R intervals and BPM heart rate measures.
Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie
2013-01-01
Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics-fractal (DFA) and recurrence (RQA) analyses-reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, "oversampled" BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics.
Using complexity metrics with R-R intervals and BPM heart rate measures
Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie
2013-01-01
Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics—fractal (DFA) and recurrence (RQA) analyses—reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, “oversampled” BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics. PMID:23964244
Accuracy of smartphone apps for heart rate measurement.
Coppetti, Thomas; Brauchlin, Andreas; Müggler, Simon; Attinger-Toller, Adrian; Templin, Christian; Schönrath, Felix; Hellermann, Jens; Lüscher, Thomas F; Biaggi, Patric; Wyss, Christophe A
2017-08-01
Background Smartphone manufacturers offer mobile health monitoring technology to their customers, including apps using the built-in camera for heart rate assessment. This study aimed to test the diagnostic accuracy of such heart rate measuring apps in clinical practice. Methods The feasibility and accuracy of measuring heart rate was tested on four commercially available apps using both iPhone 4 and iPhone 5. 'Instant Heart Rate' (IHR) and 'Heart Fitness' (HF) work with contact photoplethysmography (contact of fingertip to built-in camera), while 'Whats My Heart Rate' (WMH) and 'Cardiio Version' (CAR) work with non-contact photoplethysmography. The measurements were compared to electrocardiogram and pulse oximetry-derived heart rate. Results Heart rate measurement using app-based photoplethysmography was performed on 108 randomly selected patients. The electrocardiogram-derived heart rate correlated well with pulse oximetry ( r = 0.92), IHR ( r = 0.83) and HF ( r = 0.96), but somewhat less with WMH ( r = 0.62) and CAR ( r = 0.60). The accuracy of app-measured heart rate as compared to electrocardiogram, reported as mean absolute error (in bpm ± standard error) was 2 ± 0.35 (pulse oximetry), 4.5 ± 1.1 (IHR), 2 ± 0.5 (HF), 7.1 ± 1.4 (WMH) and 8.1 ± 1.4 (CAR). Conclusions We found substantial performance differences between the four studied heart rate measuring apps. The two contact photoplethysmography-based apps had higher feasibility and better accuracy for heart rate measurement than the two non-contact photoplethysmography-based apps.
Kur'yanova, E V; Tryasuchev, A V; Stupin, V O; Teplyi, D L
2017-05-01
We studied heart rate variability and β-adrenergic responsiveness of erythrocytes and changes in these parameters in response to single administration of β-adrenoblocker propranolol (2 mg/kg) in outbred male rats against the background of activation of the noradrenergic, serotonergic, and dopaminergic neurotransmitter systems achieved by 4-fold injections maprotiline (10 mg/kg), 5-hydroxytryptophan (50 mg/kg) combined with fluoxetine (3 mg/kg), and L-DOPA (20 mg/kg) with amantadine (20 mg/kg), respectively. Stimulation of the noradrenergic system moderately enhanced the heart rhythm rigidity and β-adrenergic responsiveness of erythrocytes. In addition, it markedly augmented the moderating effect of subsequently administered propranolol on LF and VLF components in the heart rate variability and reversed the effect of propranolol on β-adrenergic responsiveness of erythrocytes. Stimulation of the serotonergic system dramatically decreased all components in the heart rate variability and pronouncedly enhanced β-adrenergic responsiveness of erythrocytes. Subsequent injection of propranolol slightly restored all components in the heart rate variability and decreased β-adrenergic responsiveness of erythrocytes to the control level. Stimulation of the dopaminergic system made the heart rate more rigid due to decrease of all components in the heart rate variability; in addition, it slightly but significantly enhanced β-adrenergic responsiveness of erythrocytes. Subsequent injection of propranolol produced no significant effects on all components in the heart rate variability and on β-adrenergic responsiveness of erythrocytes. Stimulation of noradrenergic, serotonergic, and dopaminergic neurotransmitter systems produced unidirectional and consorted effects on heart rate variability and β-adrenergic responsiveness of erythrocytes, although the magnitudes of these effects were different. Probably, the changes in the heart rate variability in rats with stimulated neurotransmitter systems results from modification of the cellular sensitivity in peripheral organs to adrenergic influences. However, the differences in the reactions to β-adrenoblocker attest to specificity of the mechanisms underlying the changes in membrane reception and adrenergic pathways in every experimental model employed in this study.
O'Neal, Wesley T; Qureshi, Waqas T; Judd, Suzanne E; Meschia, James F; Howard, Virginia J; Howard, George; Soliman, Elsayed Z
2015-12-01
The association between resting heart rate and ischemic stroke remains unclear. To examine the association between resting heart rate and ischemic stroke. A total of 24 730 participants (mean age: 64 ± 9·3 years; 59% women; 41% blacks) from the REasons for Geographic And Racial Differences in Stroke (REGARDS) study who were free of stroke at the time of enrollment (2003-2007) were included in this analysis. Resting heart rate was determined from baseline electrocardiogram data. Heart rate was examined as a continuous variable per 10 bpm increase and also as a categorical variable using tertiles ( <61 bpm, 61 to 70 bpm, and >70 bpm). First-time ischemic stroke events were identified during follow-up and adjudicated by physician review. Over a median follow-up of 7·6 years, a total of 646 ischemic strokes occurred. In a Cox regression model adjusted for socio-demographics, cardiovascular risk factors, and potential confounders, each 10 bpm increase in heart rate was associated with a 10% increase in the risk of ischemic stroke (hazard ratio = 1·10, 95% confidence interval = 1·02, 1·18). In the categorical model, an increased risk of ischemic stroke was observed for heart rates in the middle (hazard ratio = 1·29, 95% confidence interval = 1·06, 1·57) and upper (hazard ratio = 1·37, 95% confidence interval = 1·12, 1·67) tertiles compared with the lower tertile. The results were consistent when the analysis was stratified by age, gender, race, exercise habits, hypertension, and coronary heart disease. In REGARDS, high resting heart rates were associated with an increased risk of ischemic stroke compared with low heart rates. Further research is needed to examine whether interventions aimed to reduce heart rate decrease stroke risk. © 2015 World Stroke Organization.
Franklin, Craig E; Seebacher, Frank
2003-04-01
The effect of heating and cooling on heart rate in the estuarine crocodile Crocodylus porosus was studied in response to different heat transfer mechanisms and heat loads. Three heating treatments were investigated. C. porosus were: (1) exposed to a radiant heat source under dry conditions; (2) heated via radiant energy while half-submerged in flowing water at 23 degrees C and (3) heated via convective transfer by increasing water temperature from 23 degrees C to 35 degrees C. Cooling was achieved in all treatments by removing the heat source and with C. porosus half-submerged in flowing water at 23 degrees C. In all treatments, the heart rate of C. porosus increased markedly in response to heating and decreased rapidly with the removal of the heat source. Heart rate during heating was significantly faster than during cooling at any given body temperature, i.e. there was a significant heart rate hysteresis. There were two identifiable responses to heating and cooling. During the initial stages of applying or removing the heat source, there was a dramatic increase or decrease in heart rate ('rapid response'), respectively, indicating a possible cardiac reflex. This rapid change in heart rate with only a small change or no change in body temperature (<0.5 degrees C) resulted in Q(10) values greater than 4000, calling into question the usefulness of this measure on heart rate during the initial stages of heating and cooling. In the later phases of heating and cooling, heart rate changed with body temperature, with Q(10) values of 2-3. The magnitude of the heart rate response differed between treatments, with radiant heating during submergence eliciting the smallest response. The heart rate of C. porosus outside of the 'rapid response' periods was found to be a function of the heat load experienced at the animal surface, as well as on the mode of heat transfer. Heart rate increased or decreased rapidly when C. porosus experienced large positive (above 25 W) or negative (below -15 W) heat loads, respectively, in all treatments. For heat loads between -15 W and 20 W, the increase in heart rate was smaller for the 'unnatural' heating by convection in water compared with either treatment using radiant heating. Our data indicate that changes in heart rate constitute a thermoregulatory mechanism that is modulated in response to the thermal environment occupied by the animal, but that heart rate during heating and cooling is, in part, controlled independently of body temperature.
Galetin, Thomas; Tevoufouet, Etienne E; Sandmeyer, Jakob; Matthes, Jan; Nguemo, Filomain; Hescheler, Jürgen; Weiergräber, Marco; Schneider, Toni
2013-07-01
Voltage-gated Ca(2+) channels regulate cardiac automaticity, rhythmicity and excitation-contraction coupling. Whereas L-type (Cav 1·2, Cav 1·3) and T-type (Cav 3·1, Cav 3·2) channels are widely accepted for their functional relevance in the heart, the role of Cav 2·3 Ca(2+) channels expressing R-type currents remains to be elucidated. We have investigated heart rate dynamics in control and Cav 2·3-deficient mice using implantable electrocardiogram radiotelemetry and pharmacological injection experiments. Autonomic block revealed that the intrinsic heart rate does not differ between both genotypes. Systemic administration of isoproterenol resulted in a significant reduction in interbeat interval in both genotypes. It remained unaffected after administering propranolol in Cav 2·3(-|-) mice. Heart rate from isolated hearts as well as atrioventricular conduction for both genotypes differed significantly. Additionally, we identified and analysed the developmental expression of two splice variants, i.e. Cav 2·3c and Cav 2·3e. Using patch clamp technology, R-type currents could be detected in isolated prenatal cardiomyocytes and be related to R-type Ca(2+) channels. Our results indicate that on the systemic level, the pharmacologically inducible heart rate range and heart rate reserve are impaired in Cav 2·3 (-|-) mice. In addition, experiments on Langendorff perfused hearts elucidate differences in basic properties between both genotypes. Thus, Cav 2·3 does not only contribute to the cardiac autonomous nervous system but also to intrinsic rhythm propagation. Copyright © 2012 John Wiley & Sons, Ltd.
Effect of Age and Other Factors on Maximal Heart Rate.
ERIC Educational Resources Information Center
Londeree, Ben R.; Moeschberger, Melvin L.
1982-01-01
To reduce confusion regarding reported effects of age on maximal exercise heart rate, a comprehensive review of the relevant English literature was conducted. Data on maximal heart rate after exercising with a bicycle, a treadmill, and after swimming were analyzed with regard to physical fitness and to age, sex, and racial differences. (Authors/PP)
Arduino-based noise robust online heart-rate detection.
Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda
2017-04-01
This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.
Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M
2016-10-01
Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.
Association of educational status with heart rate recovery: a population-based propensity analysis.
Shishehbor, Mehdi H; Baker, David W; Blackstone, Eugene H; Lauer, Michael S
2002-12-01
An abnormally attenuated heart rate recovery after exercise is a predictor of mortality that is thought to reflect decreased parasympathetic activity. Lower educational level may be associated with automatic imbalance. We sought to assess the association of educational level with heart rate recovery. Among 5246 healthy adults from a population-based cohort who underwent exercise testing, 874 (17%) did not graduate from high school, 1823 (35%) completed high school, and 2549 (49%) attended at least some college. An abnormal heart rate recovery was defined as a difference of =42 beats per minute between the peak heart rate and that after 2 minutes of recovery. Propensity scores were used to account for differences by educational status. An abnormal heart rate recovery was more common among adults who did not graduate from high school compared with those who attended at least some college (50% [440/874] vs. 28% [701/2549]; odds ratio [OR]: 2.7; 95% confidence interval [CI]: 2.3 to 3.1; P <0.001). After using propensity scores, lower educational status remained associated with an abnormal heart rate recovery (OR = 1.9; 95% CI: 1.6 to 2.4; P <0.001). During 12-years of follow-up, there were 327 deaths. Poor educational status was associated with greater mortality (9% [80/874] vs. 6% [247/4372]; unadjusted hazard ratio [HR] = 1.9; 95% CI: 1.4 to 2.5; P <0.001). However, after accounting for age, sex, and heart rate recovery, educational status was a weaker predictor (HR = 1.3; 95% CI: 1.0 to 1.7). Educational status is independently associated with an abnormal heart rate recovery.
Arai, Kaori; Nakagawa, Yui; Iwata, Toyoto; Horiguchi, Hyogo; Murata, Katsuyuki
2013-01-01
To clarify the links between ECG QT-related parameters and heart rate variability (HRV) and the covariates possibly distorting them, the averaged RR and QT intervals in a single lead ECG were measured for 64 male and 86 female subjects aged 18-26. The QT index, defined by Rautaharju et al., in the young adults was not significantly related to any HRV parameters nor heart rate, but the Bazett's corrected QT (QTc) interval was associated negatively with the parasympathetic activity and positively with heart rate. No significant differences in the QTc interval, QT index or heart rate were seen between the men and women, but they significantly differed between both sexes after adjustment for possible covariates such as age and body mass index (BMI). Significant sex differences in parasympathetic parameters of the HRV were unchanged before and after the adjustment, but significant differences observed in the unadjusted sympathetic parameters disappeared after adjusting for covariates. Age, BMI and body fat percentage also were significant covariates affecting these ECG parameters. Consequently, QT index, unaffected by heart rate and HRV parameters, appears to be a more useful indicator than the QTc interval. Instead, the QT index and HRV parameters are recommended to be simultaneously measured in epidemiological research because they are probably complementary in assessing autonomic nervous function. Also, these parameters should be analyzed in men and women separately. Copyright © 2012 Elsevier B.V. All rights reserved.
Casillas, Jean-Marie; Joussain, Charles; Gremeaux, Vincent; Hannequin, Armelle; Rapin, Amandine; Laurent, Yves; Benaïm, Charles
2015-02-01
To develop a new predictive model of maximal heart rate based on two walking tests at different speeds (comfortable and brisk walking) as an alternative to a cardiopulmonary exercise test during cardiac rehabilitation. Evaluation of a clinical assessment tool. A Cardiac Rehabilitation Department in France. A total of 148 patients (133 men), mean age of 59 ±9 years, at the end of an outpatient cardiac rehabilitation programme. Patients successively performed a 6-minute walk test, a 200 m fast-walk test (200mFWT), and a cardiopulmonary exercise test, with measure of heart rate at the end of each test. An all-possible regression procedure was used to determine the best predictive regression models of maximal heart rate. The best model was compared with the Fox equation in term of predictive error of maximal heart rate using the paired t-test. Results of the two walking tests correlated significantly with maximal heart rate determined during the cardiopulmonary exercise test, whereas anthropometric parameters and resting heart rate did not. The simplified predictive model with the most acceptable mean error was: maximal heart rate = 130 - 0.6 × age + 0.3 × HR200mFWT (R(2) = 0.24). This model was superior to the Fox formula (R(2) = 0.138). The relationship between training target heart rate calculated from measured reserve heart rate and that established using this predictive model was statistically significant (r = 0.528, p < 10(-6)). A formula combining heart rate measured during a safe simple fast walk test and age is more efficient than an equation only including age to predict maximal heart rate and training target heart rate. © The Author(s) 2014.
Alterations in the heart rate and activity rhythms of three orbital astronauts on a space mission.
Liu, Zhizhen; Wan, Yufeng; Zhang, Lin; Tian, Yu; Lv, Ke; Li, Yinghui; Wang, Chunhui; Chen, Xiaoping; Chen, Shanguang; Guo, Jinhu
2015-01-01
Environmental factors in space are dramatically different from those on Earth. The spaceflight environment has been known to influence human physiology and behavior on orbital missions. In this study, we investigated alterations in the diurnal rhythms of activity and heart rate of three Chinese astronauts on a space mission. An analysis of the heart rate data showed a significant decrease in heart rate amplitudes during flight in all three subjects. The heart rate amplitudes of all the three astronauts were significantly dampened during flight, and the minimum as well as the maximum value of heart rate increased after flight. A phase shift in heart rate was observed in one of the three astronauts after flight. These results demonstrate the influence of spaceflight on heart physiology and function. In addition, a significant decrease in body trunk activity and rhythmicity occurred during flight, demonstrating that the spaceflight environment disturbs motion adaptation and diurnal activity rhythms. Copyright © 2015 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
Heart Rate Assessment Immediately after Birth.
Phillipos, Emily; Solevåg, Anne Lee; Pichler, Gerhard; Aziz, Khalid; van Os, Sylvia; O'Reilly, Megan; Cheung, Po-Yin; Schmölzer, Georg M
2016-01-01
Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. PubMed, EMBASE and Google Scholar were systematically searched using the following terms: 'infant', 'heart rate', 'monitoring', 'delivery room', 'resuscitation', 'stethoscope', 'auscultation', 'palpation', 'pulse oximetry', 'electrocardiogram', 'Doppler ultrasound', 'photoplethysmography' and 'wearable sensors'. Eighteen studies were identified that described various methods of heart rate assessment in newborn infants immediately after birth. Studies examining auscultation, palpation, pulse oximetry, electrocardiography and Doppler ultrasound as ways to measure heart rate were included. Heart rate measurements by pulse oximetry are superior to auscultation and palpation, but there is contradictory evidence about its accuracy depending on whether the sensor is connected to the infant or the oximeter first. Several studies indicate that electrocardiogram provides a reliable heart rate faster than pulse oximetry. Doppler ultrasound shows potential for clinical use, however future evidence is needed to support this conclusion. Heart rate assessment is important and there are many measurement methods. The accuracy of routinely applied methods varies, with palpation and auscultation being the least accurate and electrocardiogram being the most accurate. More research is needed on Doppler ultrasound before its clinical use. © 2015 S. Karger AG, Basel.
Chou, Chia-Ying; La Marca, Roberto; Steptoe, Andrew; Brewin, Chris R.
2018-01-01
ABSTRACT Voluntary recall of trauma is a key element in exposure-based psychotherapies and can trigger spontaneous dissociative responses such as flashbacks, depersonalisation, and derealisation. In order to examine the associations between cardiovascular and psychological responses to voluntary recollection of trauma, individuals with PTSD recalled a traumatic memory. Heart rate and heart rate variability were recorded continuously and the episodes when different forms of dissociation were experienced during the recall were identified. A significant increase in parasympathetic activity was found during trauma recall, with greater parasympathetic dominance being indicative of greater state depersonalisation/derealisation. Whereas overall decreases in heart rate during trauma recall were associated with increased fear and perceived threat, flashbacks were accompanied by short-term increases in heart rate. These findings demonstrate different types of cardiovascular responses associated with different psychological experiences during trauma recall. Future research directions were discussed. PMID:29887977
Sensor fusion methods for reducing false alarms in heart rate monitoring.
Borges, Gabriel; Brusamarello, Valner
2016-12-01
Automatic patient monitoring is an essential resource in hospitals for good health care management. While alarms caused by abnormal physiological conditions are important for the delivery of fast treatment, they can be also a source of unnecessary noise because of false alarms caused by electromagnetic interference or motion artifacts. One significant source of false alarms is related to heart rate, which is triggered when the heart rhythm of the patient is too fast or too slow. In this work, the fusion of different physiological sensors is explored in order to create a robust heart rate estimation. A set of algorithms using heart rate variability index, Bayesian inference, neural networks, fuzzy logic and majority voting is proposed to fuse the information from the electrocardiogram, arterial blood pressure and photoplethysmogram. Three kinds of information are extracted from each source, namely, heart rate variability, the heart rate difference between sensors and the spectral analysis of low and high noise of each sensor. This information is used as input to the algorithms. Twenty recordings selected from the MIMIC database were used to validate the system. The results showed that neural networks fusion had the best false alarm reduction of 92.5 %, while the Bayesian technique had a reduction of 84.3 %, fuzzy logic 80.6 %, majority voter 72.5 % and the heart rate variability index 67.5 %. Therefore, the proposed algorithms showed good performance and could be useful in bedside monitors.
Azevedo, Luciene Ferreira; Perlingeiro, Patricia; Hachul, Denise Tessariol; Gomes-Santos, Igor Lucas; Tsutsui, Jeane Mike; Negrao, Carlos Eduardo; De Matos, Luciana D N J
2016-01-01
Different season trainings may influence autonomic and non-autonomic cardiac control of heart rate and provokes specific adaptations on heart's structure in athletes. We investigated the influence of transition training (TT) and competitive training (CT) on resting heart rate, its mechanisms of control, spontaneous baroreflex sensitivity (BRS) and relationships between heart rate mechanisms and cardiac structure in professional cyclists (N = 10). Heart rate (ECG) and arterial blood pressure (Pulse Tonometry) were recorded continuously. Autonomic blockade was performed (atropine-0.04 mg.kg-1; esmolol-500 μg.kg-1 = 0.5 mg). Vagal effect, intrinsic heart rate, parasympathetic (n) and sympathetic (m) modulations, autonomic influence, autonomic balance and BRS were calculated. Plasma norepinephrine (high-pressure liquid chromatography) and cardiac structure (echocardiography) were evaluated. Resting heart rate was similar in TT and CT. However, vagal effect, intrinsic heart rate, autonomic influence and parasympathetic modulation (higher n value) decreased in CT (P≤0.05). Sympathetic modulation was similar in both trainings. The autonomic balance increased in CT but still showed parasympathetic predominance. Cardiac diameter, septum and posterior wall thickness and left ventricular mass also increased in CT (P<0.05) as well as diastolic function. We observed an inverse correlation between left ventricular diastolic diameter, septum and posterior wall thickness and left ventricular mass with intrinsic heart rate. Blood pressure and BRS were similar in both trainings. Intrinsic heart rate mechanism is predominant over vagal effect during CT, despite similar resting heart rate. Preserved blood pressure levels and BRS during CT are probably due to similar sympathetic modulation in both trainings.
A protocol to study ex vivo mouse working heart at human-like heart rate.
Feng, Han-Zhong; Jin, Jian-Ping
2018-01-01
Genetically modified mice are widely used as experimental models to study human heart function and diseases. However, the fast rate of normal mouse heart at 400-600bpm limits its capacity of assessing kinetic parameters that are important for the physiology and pathophysiology of human heart that beats at a much slower rate (75-180bpm). To extend the value of mouse models, we established a protocol to study ex vivo mouse working hearts at a human-like heart rate. In the presence of 300μM lidocaine to lower pacemaker and conductive activities and prevent arrhythmia, a stable rate of 120-130bpm at 37°C is achieved for ex vivo mouse working hearts. The negative effects of decreased heart rate on force-frequency dependence and lidocaine as a myocardial depressant on intracellular calcium can be compensated by using a higher but still physiological level of calcium (2.75mM) in the perfusion media. Multiple parameters were studied to compare the function at the human-like heart rate with that of ex vivo mouse working hearts at the standard rate of 480bpm. The results showed that the conditions for slower heart rate in the presence of 300μM lidocaine did not have depressing effect on left ventricular pressure development, systolic and diastolic velocities and stroke volume with maintained positive inotropic and lusitropic responses to β-adrenergic stimulation. Compared with that at 480bpm, the human-like heart rate increased ventricular filling and end diastolic volume with enhanced Frank-Starling responses. Coronary perfusion was increased from longer relaxation time and interval between beats whereas cardiac efficiency was significantly improved. Although the intrinsic differences between mouse and human heart remain, this methodology for ex vivo mouse hearts to work at human-like heart rate extends the value of using genetically modified mouse models to study cardiac function and human heart diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.
Goshvarpour, Ateke; Goshvarpour, Atefeh
2013-02-01
The human heartbeat is one of the important examples of complex physiologic fluctuations. For the first time in this study higher order spectra of heart rate signals during meditation have explored. Specifically, the aim of this study was to analysis and compares the contribution of quadratic phase coupling of human heart rate variability during two forms of meditation: (1) Chinese Chi (or Qigong) meditation and (2) Kundalini Yoga meditation. For this purpose, Bispectrum was estimated by using biased, parametric and the direct (FFT) method. The results show that the mean Bispectrum magnitude of heart rate signals increased during Kundalini Yoga meditation, but it decreased significantly during Chi meditation. However, in both meditation techniques phase-coupled harmonics are shifted to the higher frequencies during meditation. In addition, it has shown that not only there are significant differences between rest and meditation states, but also heart rate patterns appear to be influenced by different types of meditation.
Evaluation of Dry Electrodes in Canine Heart Rate Monitoring.
Virtanen, Juhani; Somppi, Sanni; Törnqvist, Heini; Jeyhani, Vala; Fiedler, Patrique; Gizatdinova, Yulia; Majaranta, Päivi; Väätäjä, Heli; Valldeoriola Cardó, Anna; Lekkala, Jukka; Tuukkanen, Sampo; Surakka, Veikko; Vainio, Outi; Vehkaoja, Antti
2018-05-30
The functionality of three dry electrocardiogram electrode constructions was evaluated by measuring canine heart rate during four different behaviors: Standing, sitting, lying and walking. The testing was repeated (n = 9) in each of the 36 scenarios with three dogs. Two of the electrodes were constructed with spring-loaded test pins while the third electrode was a molded polymer electrode with Ag/AgCl coating. During the measurement, a specifically designed harness was used to attach the electrodes to the dogs. The performance of the electrodes was evaluated and compared in terms of heartbeat detection coverage. The effect on the respective heart rate coverage was studied by computing the heart rate coverage from the measured electrocardiogram signal using a pattern-matching algorithm to extract the R-peaks and further the beat-to-beat heart rate. The results show that the overall coverage ratios regarding the electrodes varied between 45⁻95% in four different activity modes. The lowest coverage was for lying and walking and the highest was for standing and sitting.
The effects of incubation temperature and experimental design on heart rates of lizard embryos.
Hulbert, Austin C; Mitchell, Timothy S; Hall, Joshua M; Guiffre, Cassia M; Douglas, Danielle C; Warner, Daniel A
2017-08-01
Many studies of phenotypic plasticity alter environmental conditions during embryonic development, yet only measure phenotypes at the neonatal stage (after embryonic development). However, measuring aspects of embryo physiology enhances our understanding of how environmental factors immediately affect embryos, which aids our understanding of developmental plasticity. While current research on reptile developmental plasticity has demonstrated that fluctuating incubation temperatures affect development differently than constant temperatures, most research on embryo physiology is still performed with constant temperature experiments. In this study, we noninvasively measured embryonic heart rates of the brown anole (Anolis sagrei), across ecologically relevant fluctuating temperatures. We incubated eggs under temperatures measured from potential nests in the field and examined how heart rates change through a diel cycle and throughout embryonic development. We also evaluated how experimental design (e.g., repeated vs. single measures designs, constant vs. fluctuating temperatures) and different protocols (e.g., removing eggs from incubators) might influence heart rate. We found that heart rates were correlated with daily temperature and increased through development. Our findings suggest that experimenters have reasonable flexibility in choosing an experimental design to address their questions; however, some aspects of design and protocol can potentially influence estimations of heart rates. Overall, we present the first ecologically relevant measures of anole embryonic heart rates and provide recommendations for experimental designs for future experiments. © 2017 Wiley Periodicals, Inc.
Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.
Zhang, Wei; Bogale, Saivivek; Golriz, Farahnaz; Krishnamurthy, Rajesh
2017-11-01
Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole.
Arslan, Erşan; Aras, Dicle
2016-01-01
[Purpose] The aim of this study was to compare the body composition, heart rate variability, and aerobic and anaerobic performance between competitive cyclists and triathletes. [Subjects] Six cyclists and eight triathletes with experience in competitions voluntarily participated in this study. [Methods] The subjects’ body composition was measured with an anthropometric tape and skinfold caliper. Maximal oxygen consumption and maximum heart rate were determined using the incremental treadmill test. Heart rate variability was measured by 7 min electrocardiographic recording. The Wingate test was conducted to determine anaerobic physical performance. [Results] There were significant differences in minimum power and relative minimum power between the triathletes and cyclists. Anthropometric characteristics and heart rate variability responses were similar among the triathletes and cyclists. However, triathletes had higher maximal oxygen consumption and lower resting heart rates. This study demonstrated that athletes in both sports have similar body composition and aerobic performance characteristics. PMID:27190476
A Randomized Prospective Study Of The Use Of Ipads In Reducing Anxiety During Cast Room Procedures
Ko, Justine S.; Whiting, Zachariah; Nguyen, Cynthia; Liu, Raymond W; Gilmore, Allison
2016-01-01
Background Cast room procedures can be a source of anxiety for children. Various techniques, including music therapy, have been evaluated as a way to ease this anxiety. The use of iPads as a form of distraction during cast room procedures has not previously been evaluated and was the purpose of the current study. Methods 146 children and adolescents who underwent cast room procedures during June- August 2015 were randomly assigned to one of three groups: no-iPad, iPad with video, or iPad with game. Patient heart rates were measured using a pulse oximeter in the waiting room, before the procedure, during the procedure, and after the procedure. Mean values for each group were calculated at each time interval and compared both between groups and within groups over time. Results There were no significant differences in baseline (waiting room) heart rate between the no-iPad and iPad groups. When compared with the no-iPad group, there was a trend toward decreased heart rate in the video group (p=0.13) and a significant increase in heart rate in the game group (p=0.026) before the procedure. There were no significant decreases in heart rate within any of the groups when comparing the waiting room heart rates with the during procedure heart rates. There was a significant difference between the no-iPad and video groups (p=0.047) when comparing the change in heart rate from baseline to before the procedure, with a decreased heart rate observed in the video group. Conclusions The results of this study show a significant decrease in heart rate when transitioning from the waiting room to the cast room while watching videos on the iPad. iPad-based video delivery appears to decrease anxiety prior to cast room procedures. iPad-based game play is difficult to assess as elevations in heart rate prior to the procedure are presumed to be related to game play and confound the observed effect it may have on anxiety related to the procedure. PMID:27528849
Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit.
Singh, Jasbir K S B; Kamlin, C Omar F; Morley, Colin J; O'Donnell, Colm P F; Donath, Susan M; Davis, Peter G
2008-05-01
To determine the accuracy of pulse oximetry measurement of heart rate in the neonatal intensive care unit. Stable preterm infants were monitored with a pulse oximeter and an ECG. The displays of both monitors were captured on video. Heart rate data from both monitors, including measures of signal quality, were extracted and analysed using Bland Altman plots. In 30 infants the mean (SD) difference between heart rate measured by pulse oximetry and electrocardiography was -0.4 (12) beats per minute. Accuracy was maintained when the signal quality or perfusion was low. Pulse oximetry may provide a useful measurement of heart rate in the neonatal intensive care unit. Studies of this technique in the delivery room are indicated.
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms.
Jafari Tadi, Mojtaba; Lehtonen, Eero; Hurnanen, Tero; Koskinen, Juho; Eriksson, Jonas; Pänkäälä, Mikko; Teräs, Mika; Koivisto, Tero
2016-11-01
Heart rate monitoring helps in assessing the functionality and condition of the cardiovascular system. We present a new real-time applicable approach for estimating beat-to-beat time intervals and heart rate in seismocardiograms acquired from a tri-axial microelectromechanical accelerometer. Seismocardiography (SCG) is a non-invasive method for heart monitoring which measures the mechanical activity of the heart. Measuring true beat-to-beat time intervals from SCG could be used for monitoring of the heart rhythm, for heart rate variability analysis and for many other clinical applications. In this paper we present the Hilbert adaptive beat identification technique for the detection of heartbeat timings and inter-beat time intervals in SCG from healthy volunteers in three different positions, i.e. supine, left and right recumbent. Our method is electrocardiogram (ECG) independent, as it does not require any ECG fiducial points to estimate the beat-to-beat intervals. The performance of the algorithm was tested against standard ECG measurements. The average true positive rate, positive prediction value and detection error rate for the different positions were, respectively, supine (95.8%, 96.0% and ≃0.6%), left (99.3%, 98.8% and ≃0.001%) and right (99.53%, 99.3% and ≃0.01%). High correlation and agreement was observed between SCG and ECG inter-beat intervals (r > 0.99) for all positions, which highlights the capability of the algorithm for SCG heart monitoring from different positions. Additionally, we demonstrate the applicability of the proposed method in smartphone based SCG. In conclusion, the proposed algorithm can be used for real-time continuous unobtrusive cardiac monitoring, smartphone cardiography, and in wearable devices aimed at health and well-being applications.
Design of heart rate monitor based on piezoelectric sensor using an Arduino
NASA Astrophysics Data System (ADS)
Setyowati, Veni; Muninggar, Jodelin; Shanti. N. A, Made R. S.
2017-01-01
Reading of result heart rate using an acoustic stethoscope needs a particular skill, quiet environment, and hearing sensitivity. This project had the purpose design of a user-friendly automatic heart rate monitor and especially in a noisy area which to eliminate problems and incorrect reading of result. The liquid crystal display shows a heart rate as a result of measurements. The design of the heart rate monitor has two main parts; the signal recorder that a piezoelectric sensor, a filter, and an amplifier as recorder. The second parts was Arduino microcontroller with reinforced. Besides, three supporting buttons provided as the manual switches, the ‘on’, the ‘start’, and ‘reset’ buttons. The values acquired from the heart rate monitor indicate that those were on the Vernier BPS-BTA value range. The measurement error factor of the heart rate monitor then compared to the Vernier BPS-BTA test device was 3.15%. Besides, the value of statistical independent-test indicates that there is no significant difference (P = 0.971) between the heart rate monitor device and the Vernier BPS-BTA. In conclusion, this device was ready to be used because it has almost the same accuracy with the standart device.
Robust efficient estimation of heart rate pulse from video.
Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde
2014-04-01
We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity.
Robust efficient estimation of heart rate pulse from video
Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde
2014-01-01
We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity. PMID:24761294
Optogenetic pacing in Drosophila models (Conference Presentation)
NASA Astrophysics Data System (ADS)
Wu, Penghe; Li, Airong; Men, Jing; Tans, Rudolph E.; Zhou, Chao
2017-02-01
The Drosophila melanogaster shares many similarities with vertebrates in heart development. Comparison of heart structural and functional characteristic between male and female Drosophila melanogaster at different developmental stages is helpful to understand heart morphogenesis and function for different genders. And also, it opens up the possibility to uncover the role of sex-related genes in heart development. In this longitudinal study, we cultured and tracked dozens of individually labeled flies throughout their lifecycle. The heart characteristic was measured at different developmental stages during culturing. The gender of each individual fly was determined by adult stage so that the collected data of early stages could be classified to male or female group. We adapted a high-speed optical coherence microscopy (OCM) system with axial and transverse resolution of 2um and 4um, respectively, to perform non-invasive M-mode imaging at a frame rate of 132Hz in Drosophila heart at third instar larva, early pupa and adult stage. Based on those GPU processed M-mode OCM images, we segmented the fly heart region and then quantified the cardiac structural and functional parameters such as heart rate, heart chamber size and so on. Despite large variances of wild type Drosophila in terms of some cardiac characteristic, our results suggest that the heart rate is lower for male flies than for female flies, especially at third instar larva stage. The end diastolic area (EDA) and end systolic area (ESA) of the heart are both slightly larger in female flies than in male flies at larva and adult stage. In summary, we showed gender differences of wild type drosophila in heart functional and structural characteristic.
Vinkers, C H; Breuer, M E; Westphal, K G C; Korte, S M; Oosting, R S; Olivier, B; Groenink, L
2009-03-03
Olfactory bulbectomy (OBX) in rats causes several behavioral and neurochemical changes. However, the extent and onset of physiological and behavioral changes induced after bulbectomy have been little examined. Male Sprague-Dawley rats received telemetric implants. Before and immediately after OBX surgery, basal and stress-induced heart rate, body temperature, and locomotor activity were measured in the home cage in sham (n=9) and OBX animals (n=11). Stress was induced using novel cage stress or witness stress. Bulbectomized animals differed physiologically and behaviorally from shams. Nocturnally, OBX animals were significantly more active compared with shams, had a higher core body temperature and displayed a decreased heart rate variability. During the light period, OBX animals had a significantly lower basal heart rate and a reduced heart rate variability. These effects became apparent 2-3 days after OBX surgery, and were stable over time. After witness stress, OBX animals showed smaller autonomic (body temperature and heart rate) responses compared with shams, but showed no difference in locomotor responses. In contrast, novel cage stress led to increased locomotor responses in OBX rats compared with sham rats, while no differences were found in autonomic responses. Removal of the olfactory bulbs results in rapid, stable and persistent changes in basal locomotor activity, body temperature, heart rate and heart rate variability. Although the sleep-wake cycle of these parameters is not altered, increases in circadian amplitude are apparent within 3 days after surgery. This indicates that physiological changes in the OBX rat are the immediate result of olfactory bulb removal. Further, stress responsivity in OBX rats depends on stressor intensity. Bulbectomized rats display smaller temperature and heart rate responses to less intense witness stress compared with sham rats. Increased locomotor responses to more intense novel cage stress are present in the home cage as well as the open field. The present study shows that olfactory bulbectomy has rapid and persistent influence on basal and stress-induced physiological parameters.
Miwa, Masafumi; Oishi, Kazato; Nakagawa, Yasuhiro; Maeno, Hiromichi; Anzai, Hiroki; Kumagai, Hajime; Okano, Kanji; Tobioka, Hisaya; Hirooka, Hiroyuki
2015-01-01
Estimating the energy expenditure of farm animals at pasture is important for efficient animal management. In recent years, an alternative technique for estimating energy expenditure by measuring body acceleration has been widely performed in wildlife and human studies, but the availability of the technique in farm animals has not yet been examined. In the present study, we tested the potential use of an acceleration index, overall dynamic body acceleration (ODBA), as a new proxy for estimating the energy expenditure of grazing farm animals (cattle, goats and sheep) at pasture with the simultaneous evaluation of a conventional proxy, heart rate. Body accelerations in three axes and heart rate for cows (n = 8, two breeds), goats (n = 6) and sheep (n = 5) were recorded, and the effect of ODBA calculated from the body accelerations on heart rate was analyzed. In addition, the effects of the two other activity indices, the number of steps and vectorial dynamic body acceleration (VeDBA), on heart rate were also investigated. The results of the comparison among three activity indices indicated that ODBA was the best predictor for heart rate. Although the relationship between ODBA and heart rate was different between the groups of species and breeds and between individuals (P<0.01), the difference could be explained by different body weights; a common equation could be established by correcting the body weights (M: kg): heart rate (beats/min) = 147.263∙M-0.141 + 889.640∙M-0.179∙ODBA (g). Combining this equation with the previously reported energy expenditure per heartbeat, we estimated the energy expenditure of the tested animals, and the results indicated that ODBA is a good proxy for estimating the energy expenditure of grazing farm animals across species and breeds. The utility and simplicity of the procedure with acceleration loggers could make the accelerometry technique a worthwhile option in field research and commercial farm use.
Walker, K A; Mellish, J E; Weary, D M
2011-10-01
This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.
Is sexual concordance related to awareness of physiological states?
Suschinsky, Kelly D; Lalumière, Martin L
2012-02-01
Sexual concordance refers to the degree to which two aspects of human sexual arousal (genital response and self-reported sexual arousal) correspond with each other. Researchers have consistently reported a sex difference in sexual concordance: The relationship between genital responses and reported feelings of sexual arousal in men is positive and large, whereas the relationship in women is positive but much smaller than that seen in men. The study of interoception--people's awareness of their physiological states--reveals a similar sex difference: Men are more aware of a variety of (non-genital) responses (e.g., heart rate) than women in the laboratory. The purpose of the current study was to investigate whether the sex difference in sexual concordance was related to a broader sex difference in interoception. Twenty men and 20 women were presented with twelve 90 s sexual and non-sexual film clips while their genital responses, heart rate, and respiration rate were measured. Participants also estimated their physiological responses. As expected, men were significantly more sexually concordant than women. Men were also significantly more aware of their heart rate, but there was no significant sex difference in respiration rate awareness. Sexual concordance was not significantly correlated with either heart rate or respiration rate awareness. The results suggest that the sex difference in sexual concordance may be a unique phenomenon, separate from general awareness of physiological states.
Jörn, H; Morgenstern, B; Wassenberg, B; Rath, W
2004-08-01
Is it useful to further analyse foetal heart rate to improve the prediction of pregnancy complications? The analysis of the foetal heart rate is usually based on the variability of the heart rate, i. e. the more variable the heart rate presents - except a decrease - the better the condition of the foetus is. The same concept is applied in our own analysis which differs only in the presentation of the data. We analysed 25 non-stress-tests from unselected third trimester pregnancies using sophisticated software. The recurrence plot (RP) is able to rearrange data from foetal heart rate monitoring in order to make the heart rate variability visible. We developed criteria for a normal and an abnormal test result describing the structure of the diagram to predict an uneventful and a high-risk pregnancy, respectively. 11 out of 11 patients with uneventful course and outcome of pregnancy showed a coarse and blurred RP pattern. 12 out of 14 (86 %) patients developing either intrauterine growth retardation or preeclampsia and requiring caesarean section because of foetal heart rate abnormalities showed a fine and clear RP pattern. Our preliminary results show that it makes sense to further evaluate foetal heart rate variability in order to predict pregnancy complications. Computer programs including the algorithms needed (calculation of the recurrence plot) are not expensive and easy to handle. A widespread use of these programs represents the basis requirement for large controlled clinical trials.
Kalantary, Saba; Dehghani, Ali; Yekaninejad, Mir Saeed; Omidi, Leila; Rahimzadeh, Mitra
2015-01-01
BACKGROUND One of the most important impacts of industrial noise is physiological and psychological effects. The increases in workers’ blood pressure and heart rate were detected during and after exposure to high levels of noise. The objectives of this research were to determine whether the noise exposures have any effects on blood pressure and heart rate of workers in the automotive parts industry. METHODS This case study was done in 2011 at different units of an automotive parts manufacturing in Tehran. Sound pressure level was measured at different units of the factory with a calibrated instrument. Demographic features of workers were gathered with an appropriate questionnaire. Heart rate and blood pressure were measured twice in a day in the start time of work day (before exposure to noise) and middle shift hours (during exposure to noise) in the occupational physician office. For analyzing data, chi-square, independent sample t-test, paired t-test, and analysis of covariance (ANCOVA) were used. P < 0.050 was considered statistically significant. RESULTS The average age of workers in the case and control groups was 35.71 ± 8.10 and 33.40 ± 10.41 years, respectively. There was no difference between the average age of case and control groups (P = 0.436). The results of ANCOVA revealed the significant differences between the mean changes of heart rate F (1, 37) = 26.68, P < 0.001, systolic blood pressure F (1, 37) = 21.70, P < 0.001, and diastolic blood pressure F (1, 37) = 26.20, P < 0.001 of workers in the case and control groups. CONCLUSION Exposure to industrial noise may increase the heart rate of workers. Although rises in heart rate, systolic, and diastolic blood pressure of workers in the case group were observed after exposure to noise, the values of heart rate, systolic, and diastolic blood pressure were in the normal range. Further experimental investigations are needed to determine the relationships between these variables. PMID:26478728
Tan, Fuitze; Tengah, Asrin; Nee, Lo Yah; Fredericks, Salim
2014-05-01
Music has been employed in various clinical settings to reduce anxiety. However, meta-analysis has shown music to have little influence on haemodynamic parameters. This study aimed at investigating the effect of relaxing music on heart rate recovery after exercise. Twenty-three student volunteers underwent treadmill exercise and were assessed for heart rate recovery and saliva analysis; comparing exposure to sedative music with exposure to silence during the recovery period immediately following exercise. No differences were found between music and non-music exposure regarding: heart rate recovery, resting pulse rate, and salivary cortisol. Music was no different to silence in affecting these physiological measures, which are all associated with anxiety. Relaxing music unaccompanied by meditation techniques or other such interventions may not have a major role in reducing anxiety in certain experimental settings. Copyright © 2014 Elsevier Ltd. All rights reserved.
Rate of change of heart size before congestive heart failure in dogs with mitral regurgitation.
Lord, P; Hansson, K; Kvart, C; Häggström, J
2010-04-01
The objective of the study was to examine the changes in vertebral heart scale, and left atrial and ventricular dimensions before and at onset of congestive heart failure in cavalier King Charles spaniels with mitral regurgitation. Records and radiographs from 24 cavalier King Charles spaniels with mitral regurgitation were used. Vertebral heart scale (24 dogs), and left atrial dimension and left ventricular end diastolic and end systolic diameters (18 dogs) and their rate of increase were measured at intervals over years to the onset of congestive heart failure. They were plotted against time to onset of congestive heart failure. Dimensions and rates of change of all parameters were highest at onset of congestive heart failure, the difference between observed and chance outcome being highly significant using a two-tailed chi-square test (P<0.001). The left heart chambers increase in size rapidly only in the last year before the onset of congestive heart failure. Increasing left ventricular end systolic dimension is suggestive of myocardial failure before the onset of congestive heart failure. Rate of increase of heart dimensions may be a useful indicator of impending congestive heart failure.
Heart rate estimation from FBG sensors using cepstrum analysis and sensor fusion.
Zhu, Yongwei; Fook, Victor Foo Siang; Jianzhong, Emily Hao; Maniyeri, Jayachandran; Guan, Cuntai; Zhang, Haihong; Jiliang, Eugene Phua; Biswas, Jit
2014-01-01
This paper presents a method of estimating heart rate from arrays of fiber Bragg grating (FBG) sensors embedded in a mat. A cepstral domain signal analysis technique is proposed to characterize Ballistocardiogram (BCG) signals. With this technique, the average heart beat intervals can be estimated by detecting the dominant peaks in the cepstrum, and the signals of multiple sensors can be fused together to obtain higher signal to noise ratio than each individual sensor. Experiments were conducted with 10 human subjects lying on 2 different postures on a bed. The estimated heart rate from BCG was compared with heart rate ground truth from ECG, and the mean error of estimation obtained is below 1 beat per minute (BPM). The results show that the proposed fusion method can achieve promising heart rate measurement accuracy and robustness against various sensor contact conditions.
Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P
2015-09-14
Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Sobotka, Kristina S.; Morley, Colin; Ong, Tracey; Polglase, Graeme R.; Aridas, James D. S.; Miller, Suzanne L.; Schmölzer, Georg M.; Klingenberg, Claus; Moss, Timothy J. M.; Jenkin, Graham; Hooper, Stuart B.
2014-01-01
Background A cornerstone of neonatal resuscitation teaching suggests that a rapid vagal-mediated bradycardia is one of the first signs of perinatal compromise. As this understanding is based primarily on fetal studies, we investigated whether the heart rate and blood pressure response to total asphyxia is influenced by whether the animal is in utero or ex utero. Methods Fetal sheep were instrumented at ∼139 days of gestation and then asphyxiated by umbilical cord occlusion until mean arterial blood pressure decreased to ∼20 mmHg. Lambs were either completely submerged in amniotic fluid (in utero; n = 8) throughout the asphyxia or were delivered and then remained ex utero (ex utero; n = 8) throughout the asphyxia. Heart rate and arterial blood pressure were continuously recorded. Results Heart rate was higher in ex utero lambs than in utero lambs. Heart rates in in utero lambs rapidly decreased, while heart rates in ex utero lambs initially increased following cord occlusion (for ∼1.5 min) before they started to decrease. Mean arterial pressure initially increased then decreased in both groups. Conclusions Heart rate response to asphyxia was markedly different depending upon whether the lamb was in utero or ex utero. This indicates that the cardiovascular responses to perinatal asphyxia are significantly influenced by the newborn's local environment. As such, based solely on heart rate, the stage and severity of a perinatal asphyxic event may not be as accurate as previously assumed. PMID:25393411
Sobotka, Kristina S; Morley, Colin; Ong, Tracey; Polglase, Graeme R; Aridas, James D S; Miller, Suzanne L; Schmölzer, Georg M; Klingenberg, Claus; Moss, Timothy J M; Jenkin, Graham; Hooper, Stuart B
2014-01-01
A cornerstone of neonatal resuscitation teaching suggests that a rapid vagal-mediated bradycardia is one of the first signs of perinatal compromise. As this understanding is based primarily on fetal studies, we investigated whether the heart rate and blood pressure response to total asphyxia is influenced by whether the animal is in utero or ex utero. Fetal sheep were instrumented at ∼ 139 days of gestation and then asphyxiated by umbilical cord occlusion until mean arterial blood pressure decreased to ∼ 20 mmHg. Lambs were either completely submerged in amniotic fluid (in utero; n = 8) throughout the asphyxia or were delivered and then remained ex utero (ex utero; n = 8) throughout the asphyxia. Heart rate and arterial blood pressure were continuously recorded. Heart rate was higher in ex utero lambs than in utero lambs. Heart rates in in utero lambs rapidly decreased, while heart rates in ex utero lambs initially increased following cord occlusion (for ∼ 1.5 min) before they started to decrease. Mean arterial pressure initially increased then decreased in both groups. Heart rate response to asphyxia was markedly different depending upon whether the lamb was in utero or ex utero. This indicates that the cardiovascular responses to perinatal asphyxia are significantly influenced by the newborn's local environment. As such, based solely on heart rate, the stage and severity of a perinatal asphyxic event may not be as accurate as previously assumed.
Zhao, Shun-yun; Wu, Xin-min; Guo, Ya-min; Zhang, Shu-shun; An, Yan-ming; Li, Bing; Wang, Hao
2013-06-11
To explore the blood oxygen saturation and heart rate changes of the Antarctic explorers. During August 2010 to April 2011, the changes in blood oxygen saturation, heart rate and plateau reaction of 16 Antarctic expedition team in different plateau environments (Tibetan plateau versus Antarctic plateau) were monitored with the noninvasive pulse oximeter MD300-C. The extent of acute mountain sickness was determined according to the Lake Louise Consensus acute mountain reaction symptom scores and judgment method. The changes of blood oxygen saturation, heart rate at different altitudes of 110, 3650, 4300 m (96.8% ± 1.2%,89.1% ± 1.2%, 86.1% ± 2.0%, (75.0 ± 5.4) times/min, (104.0 ± 4.3) times/min, (113.0 ± 5.2) times/min,F = 214.155, 240.088,both P < 0.05). With rising latitude and elevation gradient in Antarctic plateau, the changes of blood oxygen saturation, heart rate at different altitudes of 2000, 2500, 3000, 3500 and 4087 m(91.9% ± 1.3%,90.5% ± 1.3%,87.6% ± 1.4%,85.0% ± 1.8%,81.5% ± 2.2%, (85.9 ± 3.2) times/min, (90.6 ± 2.8) times/min, (97.8 ± 4.1) times/min, (102.0 ± 3.4) times/min, (106.3 ± 3.9) times/min, F = 105.418, 90.174, both P < 0.05). Levels of blood oxygen saturation and heart rate were both correlated with the risk of altitude sickness (r = -0.446 and 0.565, both P < 0.05). As the increases of altitude, there are significant changes in oxygen saturation, heart rate of the Antarctic explorers. And with the increases of altitude, the risk of altitude sickness gradually increases.
Algorithm for heart rate extraction in a novel wearable acoustic sensor
Imtiaz, Syed Anas; Aguilar–Pelaez, Eduardo; Rodriguez–Villegas, Esther
2015-01-01
Phonocardiography is a widely used method of listening to the heart sounds and indicating the presence of cardiac abnormalities. Each heart cycle consists of two major sounds – S1 and S2 – that can be used to determine the heart rate. The conventional method of acoustic signal acquisition involves placing the sound sensor at the chest where this sound is most audible. Presented is a novel algorithm for the detection of S1 and S2 heart sounds and the use of them to extract the heart rate from signals acquired by a small sensor placed at the neck. This algorithm achieves an accuracy of 90.73 and 90.69%, with respect to heart rate value provided by two commercial devices, evaluated on more than 38 h of data acquired from ten different subjects during sleep in a pilot clinical study. This is the largest dataset for acoustic heart sound classification and heart rate extraction in the literature to date. The algorithm in this study used signals from a sensor designed to monitor breathing. This shows that the same sensor and signal can be used to monitor both breathing and heart rate, making it highly useful for long-term wearable vital signs monitoring. PMID:26609401
Interictal cardiorespiratory variability in temporal lobe and absence epilepsy in childhood.
Varon, Carolina; Montalto, Alessandro; Jansen, Katrien; Lagae, Lieven; Marinazzo, Daniele; Faes, Luca; Van Huffel, Sabine
2015-04-01
It is well known that epilepsy has a profound effect on the autonomic nervous system, especially on the autonomic control of heart rate and respiration. This effect has been widely studied during seizure activity, but less attention has been given to interictal (i.e. seizure-free) activity. The studies that have been done on this topic, showed that heart rate and respiration can be affected individually, even without the occurrence of seizures. In this work, the interactions between these two individual physiological variables are analysed during interictal activity in temporal lobe and absence epilepsy in childhood. These interactions are assessed by decomposing the predictive information about heart rate variability, into different components like the transfer entropy, cross-entropy, self- entropy and the conditional self entropy. Each one of these components quantifies different types of shared information. However, when using the cross-entropy and the conditional self entropy, it is possible to split the information carried by the heart rate, into two main components, one related to respiration and one related to different mechanisms, like sympathetic activation. This can be done after assuming a directional link going from respiration to heart rate. After analysing all the entropy components, it is shown that in subjects with absence epilepsy the information shared by respiration and heart rate is significantly lower than for normal subjects. And a more remarkable finding indicates that this type of epilepsy seems to have a long term effect on the cardiac and respiratory control mechanisms of the autonomic nervous system.
AUTONOMIC CONTROL OF HEART RATE AFTER EXERCISE IN TRAINED WRESTLERS
Báez, San Martín E.; Von Oetinger, A.; Cañas, Jamett R.; Ramírez, Campillo R.
2013-01-01
The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW). A total of 18 male athletes were evaluated, ten highly trained (HT) and eight moderately trained (MT), who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s), and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability – SD1) analysis of heart rate variability (HRV), using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s). Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05) and in the non linear analysis of HRV from SD130-45s (p <0.05) and SD145-60s (p <0.05). The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW. PMID:24744476
Dynamic neural networking as a basis for plasticity in the control of heart rate.
Kember, G; Armour, J A; Zamir, M
2013-01-21
A model is proposed in which the relationship between individual neurons within a neural network is dynamically changing to the effect of providing a measure of "plasticity" in the control of heart rate. The neural network on which the model is based consists of three populations of neurons residing in the central nervous system, the intrathoracic extracardiac nervous system, and the intrinsic cardiac nervous system. This hierarchy of neural centers is used to challenge the classical view that the control of heart rate, a key clinical index, resides entirely in central neuronal command (spinal cord, medulla oblongata, and higher centers). Our results indicate that dynamic networking allows for the possibility of an interplay among the three populations of neurons to the effect of altering the order of control of heart rate among them. This interplay among the three levels of control allows for different neural pathways for the control of heart rate to emerge under different blood flow demands or disease conditions and, as such, it has significant clinical implications because current understanding and treatment of heart rate anomalies are based largely on a single level of control and on neurons acting in unison as a single entity rather than individually within a (plastically) interconnected network. Copyright © 2012 Elsevier Ltd. All rights reserved.
Autonomic control of heart rate after exercise in trained wrestlers.
Henríquez, Olguín C; Báez, San Martín E; Von Oetinger, A; Cañas, Jamett R; Ramírez, Campillo R
2013-06-01
The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW). A total of 18 male athletes were evaluated, ten highly trained (HT) and eight moderately trained (MT), who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s), and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability - SD1) analysis of heart rate variability (HRV), using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s). Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05) and in the non linear analysis of HRV from SD130-45s (p <0.05) and SD145-60s (p <0.05). The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW.
Zimmer, M B; Milsom, W K
2001-01-01
To determine whether metabolic rate is suppressed in a temperature-independent fashion in the golden-mantled ground squirrel during steady state hibernation, we measured body temperature and metabolic rate in ground squirrels during hibernation at different T(a)'s. In addition, we attempted to determine whether heart rate, ventilation rate, and breathing patterns changed as a function of body temperature or metabolic rate. We found that metabolic rate changed with T(a) as it was raised from 5 degrees to 14 degrees C, which supports the theory that different species sustain falls in metabolic rate during hibernation in different ways. Heart rate and breathing pattern also changed with changing T(a), while breathing frequency did not. That the total breathing frequency did not correlate closely with oxygen consumption or body temperature, while the breathing pattern did, raises important questions regarding the mechanisms controlling ventilation during hibernation.
Kong, Melissa H; Shaw, Linda K; O'Connor, Christopher; Califf, Robert M; Blazing, Michael A; Al-Khatib, Sana M
2010-07-01
Although no clinical trial data exist on the optimal management of atrial fibrillation (AF) in patients with diastolic heart failure, it has been hypothesized that rhythm-control is more advantageous than rate-control due to the dependence of these patients' left ventricular filling on atrial contraction. We aimed to determine whether patients with AF and heart failure with preserved ejection fraction (EF) survive longer with rhythm versus rate-control strategy. The Duke Cardiovascular Disease Database was queried to identify patients with EF > 50%, heart failure symptoms and AF between January 1,1995 and June 30, 2005. We compared baseline characteristics and survival of patients managed with rate- versus rhythm-control strategies. Using a 60-day landmark view, Kaplan-Meier curves were generated and results were adjusted for baseline differences using Cox proportional hazards modeling. Three hundred eighty-two patients met the inclusion criteria (285 treated with rate-control and 97 treated with rhythm-control). The 1-, 3-, and 5-year survival rates were 93.2%, 69.3%, and 56.8%, respectively in rate-controlled patients and 94.8%, 78.0%, and 59.9%, respectively in rhythm-controlled patients (P > 0.10). After adjustments for baseline differences, no significant difference in mortality was detected (hazard ratio for rhythm-control vs rate-control = 0.696, 95% CI 0.453-1.07, P = 0.098). Based on our observational data, rhythm-control seems to offer no survival advantage over rate-control in patients with heart failure and preserved EF. Randomized clinical trials are needed to verify these findings and examine the effect of each strategy on stroke risk, heart failure decompensation, and quality of life.
Koplay, Mustafa; Celik, Mahmut; Avcı, Ahmet; Erdogan, Hasan; Demir, Kenan; Sivri, Mesut; Nayman, Alaaddin
2015-01-01
We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated "Flash Spiral" technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT. A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared. A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60-75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47-2.01 mSv) for method A and 8.22 mSv (2.19-12.88 mSv) for method B. Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.
Quantification of fetal heart rate regularity using symbolic dynamics
NASA Astrophysics Data System (ADS)
van Leeuwen, P.; Cysarz, D.; Lange, S.; Geue, D.; Groenemeyer, D.
2007-03-01
Fetal heart rate complexity was examined on the basis of RR interval time series obtained in the second and third trimester of pregnancy. In each fetal RR interval time series, short term beat-to-beat heart rate changes were coded in 8bit binary sequences. Redundancies of the 28 different binary patterns were reduced by two different procedures. The complexity of these sequences was quantified using the approximate entropy (ApEn), resulting in discrete ApEn values which were used for classifying the sequences into 17 pattern sets. Also, the sequences were grouped into 20 pattern classes with respect to identity after rotation or inversion of the binary value. There was a specific, nonuniform distribution of the sequences in the pattern sets and this differed from the distribution found in surrogate data. In the course of gestation, the number of sequences increased in seven pattern sets, decreased in four and remained unchanged in six. Sequences that occurred less often over time, both regular and irregular, were characterized by patterns reflecting frequent beat-to-beat reversals in heart rate. They were also predominant in the surrogate data, suggesting that these patterns are associated with stochastic heart beat trains. Sequences that occurred more frequently over time were relatively rare in the surrogate data. Some of these sequences had a high degree of regularity and corresponded to prolonged heart rate accelerations or decelerations which may be associated with directed fetal activity or movement or baroreflex activity. Application of the pattern classes revealed that those sequences with a high degree of irregularity correspond to heart rate patterns resulting from complex physiological activity such as fetal breathing movements. The results suggest that the development of the autonomic nervous system and the emergence of fetal behavioral states lead to increases in not only irregular but also regular heart rate patterns. Using symbolic dynamics to examine the cardiovascular system may thus lead to new insight with respect to fetal development.
Shuvy, Mony; Arbelle, Jonathan E; Grosbard, Aviva; Katz, Amos
2008-01-01
Heart rate variability is a sensitive marker of cardiac sympathetic activity. To determine whether long-term hyperthyroidism induced by thyroxine suppressive therapy affects HRV. Nineteen patients treated with suppressive doses of thyroxin for thyroid cancer and 19 age-matched controls were enrolled. Thyroid function tests and 1 minute HRV were performed on all subjects and the results were compared between the groups. The 1 minute HRV was analyzed during deep breathing and defined as the difference in beats/minute between the shortest and the longest heart rate interval measured by eletrocardiographic recording during six cycles of deep breathing. One minute HRV during deep breathing was significantly lower among thyroxine-treated patients compared to healthy controls (25.6 +/- 10.5 vs. 34.3 +/- 12.6 beats/min, P < 0.05). There were no significant differences in mean, maximal and minimal heart rate between the groups. Thyroxine therapy administered for epithelial thyroid cancer resulted in subclinical hyperthyroidism and significantly decreased HRV due to autonomic dysfunction rather than basic elevated heart rate.
Relationships between heart rate and age, bodyweight and breed in 10,849 dogs.
Hezzell, M J; Dennis, S G; Humm, K; Agee, L; Boswood, A
2013-06-01
To evaluate relationships between heart rate and clinical variables in healthy dogs and dogs examined at a referral hospital. Clinical data were extracted from the electronic patient records of a first opinion group (5000 healthy dogs) and a referral hospital (5849 dogs). Univariable and multi-variable general linear models were used to assess associations between heart rate and clinical characteristics. Separate multi-variable models were constructed for first opinion and referral populations. In healthy dogs, heart rate was negatively associated with bodyweight (P<0.001) but was higher in Chihuahuas. The mean difference in heart rate between a 5 and 55 kg dog was 10.5 beats per minute. In dogs presenting to a referral hospital, heart rate was negatively associated with bodyweight (P<0.001) and the following breeds; border collie, golden retriever, Labrador retriever, springer spaniel and West Highland white terrier and positively associated with age, admitting service (emergency and critical care, emergency first opinion and cardiology) and the following breeds; Cavalier King Charles spaniel, Staffordshire bull terrier and Yorkshire terrier. Bodyweight, age, breed and disease status all influence heart rate in dogs, although these factors account for a relatively small proportion of the overall variability in heart rate. © 2013 British Small Animal Veterinary Association.
Heart rate and treatment effect in children with disruptive behavior disorders.
Stadler, Christina; Grasmann, Dörte; Fegert, Jörg M; Holtmann, Martin; Poustka, Fritz; Schmeck, Klaus
2008-09-01
To examine whether children with disruptive behavior disorders (DBDs; hyperkinetic conduct disorder, conduct disorder, hyperkinetic disorder) characterized by low heart rate profit less from an intensive cognitive behavioral intervention aimed at reducing impulsive, oppositional and aggressive behavior problems. Basal heart rate was studied in twenty-three children (aged 7-12 years) with DBD at the beginning of intervention comprising an intensive day-care treatment and parent training. The disruptive behavior of the child was assessed before treatment and after termination (12 weeks later). Therapy responders and non-responders were compared in regard to heart rate and other risk factors (cognitive functioning and socio-economic status). Statistical analyses yielded evidence for a significant reduction of disruptive problem behaviors (aggression, delinquency) that is more prominent in DBD children with high heart rate scores compared to patients with low heart rate scores. Heart rate was significantly lower in children who did not profit from therapy. A logistic regression analysis revealed that heart rate is a significant predictor for therapy success whereas other risk factors had no impact on therapy success. Further studies investigating biological and psychosocial predictors of treatment effectiveness are necessary. In addition, it might be helpful to consider different subtypes of aggressive behavior for selecting the best possible treatment options.
Accuracy of pulse oximeters in estimating heart rate at rest and during exercise.
Iyriboz, Y; Powers, S; Morrow, J; Ayers, D; Landry, G
1991-01-01
Pulse oximeters are being widely used for non-invasive, simultaneous assessment of haemoglobin oxygen saturation. They are reliable, accurate, relatively inexpensive and portable. Pulse oximeters are often used for estimating heart rate at rest and during exercise. However, at present the data available to validate their use as heart rate monitors are not sufficient. We evaluated the accuracy of two oximeters (Radiometer, ear and finger probe; Ohmeda 3700, ear probe) in monitoring heart rate during incremental exercise by comparing the pulse oximeters with simultaneous ECG readings. Data were collected on eight men (713 heart rate readings) during graded cycle ergometer and treadmill exercise to volitional fatigue. Analysis by linear regression revealed that general oximeter readings significantly correlated with those of ECG (r = 0.91, P less than 0.0001). However, comparison of heart rate at each level of work showed that oximeter readings significantly (P less than 0.05) under-estimated rates above 155 beats/min. These results indicate that the use of pulse oximeters as heart rate monitors during strenuous exercise is questionable. This inaccuracy may well originate from the instability of the probes, sweating, other artefacts during exercise, and measurement of different components in the cardiovascular cycle. PMID:1777787
Lerma, Claudia; Wessel, Niels; Schirdewan, Alexander; Kurths, Jürgen; Glass, Leon
2008-07-01
The objective was to determine the characteristics of heart rate variability and ventricular arrhythmias prior to the onset of ventricular tachycardia (VT) in patients with an implantable cardioverter defibrillator (ICD). Sixty-eight beat-to-beat time series from 13 patients with an ICD were analyzed to quantify heart rate variability and ventricular arrhythmias. The episodes of VT were classified in one of two groups depending on whether the sinus rate in the 1 min preceding the VT was greater or less than 90 beats per minute. In a subset of patients, increased heart rate and reduced heart rate variability was often observed up to 20 min prior to the VT. There was a non-significant trend to higher incidence of premature ventricular complexes (PVCs) before VT compared to control recordings. The patterns of the ventricular arrhythmias were highly heterogeneous among different patients and even within the same patient. Analysis of the changes of heart rate and heart rate variability may have predictive value about the onset of VT in selected patients. The patterns of ventricular arrhythmia could not be used to predict onset of VT in this group of patients.
Squara, F; Theodore, G; Scarlatti, D; Ferrari, E
2017-02-01
We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Griefahn, Barbara; Künemund, Christa; Blaszkewicz, Meinolf; Lerchl, Alexander; Degen, Gisela H
2002-10-01
Electromagnetic spectra reduce melatonin production and delay the nadirs of rectal temperature and heart rate. Seven healthy men (16-22 yrs) completed 4 permuted sessions. The control session consisted of a 24-hours bedrest at < 30 lux, 18 degrees C, and < 50 dBA. In the experimental sessions, either light (1500 lux), magnetic field (16.7 Hz, 0.2 mT), or infrared radiation (65 degrees C) was applied from 5 pm to 1 am. Salivary melatonin level was determined hourly, rectal temperature and heart rate were continuously recorded. Melatonin synthesis was completely suppressed by light but resumed thereafter. The nadirs of rectal temperature and heart rate were delayed. The magnetic field had no effect. Infrared radiation elevated rectal temperature and heart rate. Only bright light affected the circadian rhythms of melatonin synthesis, rectal temperature, and heart rate, however, differently thus causing a dissociation, which might enhance the adverse effects of shiftwork in the long run.
Clemente, Filipe Manuel; González-Víllora, Sixto; Delextrat, Anne; Martins, Fernando Manuel Lourenço; Vicedo, Juan Carlos Pastor
2017-01-01
Abstract The aim of this study was to analyze the effect of different small-sided and conditioning games (SSCG) with different tactical contents on heart rate responses, technical performance and collective organization of youth basketball players of different performance levels. Twenty male basketball players from U14 (13.7 ± 0.8 years old; 4.2 ± 1.4 years of practice) and U16 (15.3 ± 1.1 years old; 6.4 ± 2.1 years of practice) participated in this research study. The two-way MANOVA revealed that the sports level (p = 0.009; ηp2 = 0.151), format (p = 0.001; ηp2 = 0.246) and task condition (p = 0.023; ηp2 = 0.104; small effect size) had significant main effects on heart rate responses. It was also found that the format (p = 0.001; ηp2 = 0.182) had significant main effects on technical performance. A smaller format significantly increased the heart rate, volume of play, efficiency index and collective density during attacking plays. The SSCG with attacking content statistically increased the heart rate, efficiency index and performance score. Therefore, this study revealed that different SSCGs with tactical content influenced the physiological responses of youth players. PMID:28828085
Effect of Heart rate on Basketball Three-Point Shot Accuracy
Ardigò, Luca P.; Kuvacic, Goran; Iacono, Antonio D.; Dascanio, Giacomo; Padulo, Johnny
2018-01-01
The three-point shot (3S) is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S%) in 24 male (Under 17) basketball players (age 16.3 ± 0.6 yrs). 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spots just beyond the FIBA three-point line, i.e., about 7 m from the basket (two counter-clockwise “laps”) at different heart rates: rest (0HR), after warm-up (50%HRMAX [50HR]), and heart rate corresponding to 80% of its maximum value (80%HRMAX [80HR]). We found that 50HR does not significantly decrease 3S% (−15%, P = 0.255), while 80HR significantly does when compared to 0HR (−28%, P = 0.007). Given that 50HR does not decrease 3S% compared to 0HR, we believe that no preliminary warm-up is needed before entering a game in order to specifically achieve a high 3S%. Furthermore, 3S training should be performed in conditions of moderate-to-high fatigued state so that a high 3S% can be maintained during game-play. PMID:29467676
Mather, Mara; Yoo, Hyun Joo; Clewett, David V.; Lee, Tae-Ho; Greening, Steven G.; Ponzio, Allison; Min, Jungwon; Thayer, Julian F.
2017-01-01
The locus coeruleus (LC) is a key node of the sympathetic nervous system and suppresses parasympathetic activity that would otherwise increase heart rate variability. In the current study, we examined whether LC-MRI contrast reflecting neuromelanin accumulation in the LC was associated with high-frequency heart rate variability (HF-HRV), a measure reflecting parasympathetic influences on the heart. Recent evidence indicates that neuromelanin, a byproduct of catecholamine metabolism, accumulates in the LC through young and mid adulthood, suggesting that LC-MRI contrast may be a useful biomarker of individual differences in habitual LC activation. We found that, across younger and older adults, greater LC-MRI contrast was negatively associated with HF-HRV during fear conditioning and spatial detection tasks. This correlation was not accounted for by individual differences in age or anxiety. These findings indicate that individual differences in LC structure relate to key cardiovascular parameters. PMID:28215623
Cygankiewicz, Iwona
2013-01-01
Heart rate turbulence (HRT) is a baroreflex-mediated biphasic reaction of heart rate in response to premature ventricular beats. Heart rate turbulence is quantified by: turbulence onset (TO) reflecting the initial acceleration of heart rate following premature beat and turbulence slope (TS) describing subsequent deceleration of heart rate. Abnormal HRT identifies patients with autonomic dysfunction or impaired baroreflex sensitivity due to variety of disorders, but also may reflect changes in autonomic nervous system induced by different therapeutic modalities such as drugs, revascularization, or cardiac resynchronization therapy. More importantly, impaired HRT has been shown to identify patients at high risk of all-cause mortality and sudden death, particularly in postinfarction and congestive heart failure patients. It should be emphasized that abnormal HRT has a well-established role in stratification of postinfarction and heart failure patients with relatively preserved left ventricular ejection fraction. The ongoing clinical trials will document whether HRT can be used to guide implantation of cardioverter-defibrillators in this subset of patients, not covered yet by ICD guidelines. This review focuses on the current state-of-the-art knowledge regarding clinical significance of HRT in detection of autonomic dysfunction and regarding the prognostic significance of this parameter in predicting all-cause mortality and sudden death. © 2013.
Seebacher, F
2000-03-21
Thermally-induced changes in heart rate and blood flow in reptiles are believed to be of selective advantage by allowing animal to exert some control over rates of heating and cooling. This notion has become one of the principal paradigms in reptilian thermal physiology. However, the functional significance of changes in heart rate is unclear, because the effect of heart rate and blood flow on total animal heat transfer is not known. I used heat transfer theory to determine the importance of heat transfer by blood flow relative to conduction. I validated theoretical predictions by comparing them with field data from two species of lizard, bearded dragons (Pogona barbata) and lace monitors (Varanus varius). Heart rates measured in free-ranging lizards in the field were significantly higher during heating than during cooling, and heart rates decreased with body mass. Convective heat transfer by blood flow increased with heart rate. Rates of heat transfer by both blood flow and conduction decreased with mass, but the mass scaling exponents were different. Hence, rate of conductive heat transfer decreased more rapidly with increasing mass than did heat transfer by blood flow, so that the relative importance of blood flow in total animal heat transfer increased with mass. The functional significance of changes in heart rate and, hence, rates of heat transfer, in response to heating and cooling in lizards was quantified. For example, by increasing heart rate when entering a heating environment in the morning, and decreasing heart rate when the environment cools in the evening a Pogona can spend up to 44 min longer per day with body temperature within its preferred range. It was concluded that changes in heart rate in response to heating and cooling confer a selective advantage at least on reptiles of mass similar to that of the study animals (0. 21-5.6 kg). Copyright 2000 Academic Press.
NASA Astrophysics Data System (ADS)
Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.
Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.
Vedder, Oscar; Kürten, Nathalie; Bouwhuis, Sandra
Embryonic development time is thought to impact life histories through trade-offs against life-history traits later in life, yet the inference is based on interspecific comparative analyses only. It is largely unclear whether intraspecific variation in embryonic development time that is not caused by environmental differences occurs, which would be required to detect life-history trade-offs. Here we performed a classical common-garden experiment by incubating fresh eggs of free-living common terns (Sterna hirundo) in a controlled incubation environment at two different temperatures. Hatching success was high but was slightly lower at the lower temperature. While correcting for effects of year, incubation temperature, and laying order, we found significant variation in the incubation time embryos required until hatching and in their heart rate. Embryonic heart rate was significantly positively correlated within clutches, and a similar tendency was found for incubation time, suggesting that intrinsic differences in embryonic development rate between offspring of different parents exist. Incubation time and embryonic heart rate were strongly correlated: embryos with faster heart rates required shorter incubation time. However, after correction for heart rate, embryos still required more time for development at the lower incubation temperature. This suggests that processes other than development require a greater share of resources in a suboptimal environment and that relative resource allocation to development is, therefore, environment dependent. We conclude that there is opportunity to detect intraspecific life-history trade-offs with embryonic development time and that the resolution of trade-offs may differ between embryonic environments.
NASA Astrophysics Data System (ADS)
Chen, Liang-Kuang; Wu, Tung-Hsin; Yang, Ching-Ching; Tsai, Chia-Jung; Lee, Jason J. S.
2010-07-01
The aim of this study is to assess radiation dose and the corresponding image quality from suggested CT protocols which depends on different mean heart rate and high heart rate variability by using 256-slice CT. Fifty consecutive patients referred for a cardiac CT examination were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on a 256-slice CT scanner with one of five different protocols: retrospective ECG-gating (RGH) with full dose exposure in all R-R intervals (protocol A), RGH of 30-80% pulsing window with tube current modulation (B), RGH of 78±5% pulsing window with tube current modulation (C), prospective ECG-triggering (PGT) of 78% R-R interval with 5% padding window (D) and PGT of 78% R-R interval without padding window (E). Radiation dose parameters and image quality scoring were determined and compared. In this study, no significant differences were found in comparison on image quality of the five different protocols. Protocol A obtained the highest radiation dose comparing with those of protocols B, C, D and E by a factor of 1.6, 2.4, 2.5 and 4.3, respectively ( p<0.001), which were ranged between 2.7 and 11.8 mSv. The PGT could significantly reduce radiation dose delivered to patients, as compared to the RGH. However, the use of PGT has limitations and is only good in assessing cases with lower mean heart rate and stable heart rate variability. With higher mean heart rate and high heart rate variability circumstances, the RGH within 30-80% of R-R interval pulsing window is suggested as a feasible technique for assessing diagnostic performance.
Compression based entropy estimation of heart rate variability on multiple time scales.
Baumert, Mathias; Voss, Andreas; Javorka, Michal
2013-01-01
Heart rate fluctuates beat by beat in a complex manner. The aim of this study was to develop a framework for entropy assessment of heart rate fluctuations on multiple time scales. We employed the Lempel-Ziv algorithm for lossless data compression to investigate the compressibility of RR interval time series on different time scales, using a coarse-graining procedure. We estimated the entropy of RR interval time series of 20 young and 20 old subjects and also investigated the compressibility of randomly shuffled surrogate RR time series. The original RR time series displayed significantly smaller compression entropy values than randomized RR interval data. The RR interval time series of older subjects showed significantly different entropy characteristics over multiple time scales than those of younger subjects. In conclusion, data compression may be useful approach for multiscale entropy assessment of heart rate variability.
Clark, Steven L; Hamilton, Emily F; Garite, Thomas J; Timmins, Audra; Warrick, Philip A; Smith, Samuel
2017-02-01
Despite intensive efforts directed at initial training in fetal heart rate interpretation, continuing medical education, board certification/recertification, team training, and the development of specific protocols for the management of abnormal fetal heart rate patterns, the goals of consistently preventing hypoxia-induced fetal metabolic acidemia and neurologic injury remain elusive. The purpose of this study was to validate a recently published algorithm for the management of category II fetal heart rate tracings, to examine reasons for the birth of infants with significant metabolic acidemia despite the use of electronic fetal heart rate monitoring, and to examine critically the limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic acidemia. The potential performance of electronic fetal heart rate monitoring under ideal circumstances was evaluated in an outcomes-blinded examination fetal heart rate tracing of infants with metabolic acidemia at birth (base deficit, >12) and matched control infants (base deficit, <8) under the following conditions: (1) expert primary interpretation, (2) use of a published algorithm that was developed and endorsed by a large group of national experts, (3) assumption of a 30-minute period of evaluation for noncritical category II fetal heart rate tracings, followed by delivery within 30 minutes, (4) evaluation without the need to provide patient care simultaneously, and (5) comparison of results under these circumstances with those achieved in actual clinical practice. During the study period, 120 infants were identified with an arterial cord blood base deficit of >12 mM/L. Matched control infants were not demographically different from subjects. In actual practice, operative intervention on the basis of an abnormal fetal heart rate tracings occurred in 36 of 120 fetuses (30.0%) with metabolic acidemia. Based on expert, algorithm-assisted reviews, 55 of 120 patients with acidemia (45.8%) were judged to need operative intervention for abnormal fetal heart rate tracings. This difference was significant (P=.016). In infants who were born with a base deficit of >12 mM/L in which blinded, algorithm-assisted expert review indicated the need for operative delivery, the decision for delivery would have been made an average of 131 minutes before the actual delivery. The rate of expert intervention for fetal heart rate concerns in the nonacidemic control group (22/120; 18.3%) was similar to the actual intervention rate (23/120; 19.2%; P=1.0) Expert review did not mandate earlier delivery in 65 of 120 patients with metabolic acidemia. The primary features of these 65 cases included the occurrence of sentinel events with prolonged deceleration just before delivery, the rapid deterioration of nonemergent category II fetal heart rate tracings before realistic time frames for recognition and intervention, and the failure of recognized fetal heart rate patterns such as variability to identify metabolic acidemia. Expert, algorithm-assisted fetal heart rate interpretation has the potential to improve standard clinical performance by facilitating significantly earlier recognition of some tracings that are associated with metabolic acidemia without increasing the rate of operative intervention. However, this improvement is modest. Of infants who are born with metabolic acidemia, only approximately one-half potentially could be identified and have delivery expedited even under ideal circumstances, which are probably not realistic in current US practice. This represents the limits of electronic fetal heart rate monitoring performance. Additional technologies will be necessary if the goal of the prevention of neonatal metabolic acidemia is to be realized. Copyright © 2016 Elsevier Inc. All rights reserved.
Nemati, Shamim; Edwards, Bradley A.; Lee, Joon; Pittman-Polletta, Benjamin; Butler, James P.; Malhotra, Atul
2013-01-01
Aging and disease are accompanied with a reduction of complex variability in the temporal patterns of heart rate. This reduction has been attributed to a break down of the underlying regulatory feedback mechanisms that maintain a homeodynamic state. Previous work has established the utility of entropy as an index of disorder, for quantification of changes in heart rate complexity. However, questions remain regarding the origin of heart rate complexity and the mechanisms involved in its reduction with aging and disease. In this work we use a newly developed technique based on the concept of band-limited transfer entropy to assess the aging-related changes in contribution of respiration and blood pressure to entropy of heart rate at different frequency bands. Noninvasive measurements of heart beat interval, respiration, and systolic blood pressure were recorded from 20 young (21–34 years) and 20 older (68–85 years) healthy adults. Band-limited transfer entropy analysis revealed a reduction in high-frequency contribution of respiration to heart rate complexity (p < 0.001) with normal aging, particularly in men. These results have the potential for dissecting the relative contributions of respiration and blood pressure-related reflexes to heart rate complexity and their degeneration with normal aging. PMID:23811194
Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P
2015-01-01
Background Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. Methods and Results We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Conclusions Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. Clinical Trial Registration URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. PMID:26370445
Patterns of Interspecific Variation in the Heart Rates of Embryonic Reptiles
Du, Wei-Guo; Ye, Hua; Zhao, Bo; Pizzatto, Ligia; Ji, Xiang; Shine, Richard
2011-01-01
New non-invasive technologies allow direct measurement of heart rates (and thus, developmental rates) of embryos. We applied these methods to a diverse array of oviparous reptiles (24 species of lizards, 18 snakes, 11 turtles, 1 crocodilian), to identify general influences on cardiac rates during embryogenesis. Heart rates increased with ambient temperature in all lineages, but (at the same temperature) were faster in lizards and turtles than in snakes and crocodilians. We analysed these data within a phylogenetic framework. Embryonic heart rates were faster in species with smaller adult sizes, smaller egg sizes, and shorter incubation periods. Phylogenetic changes in heart rates were negatively correlated with concurrent changes in adult body mass and residual incubation period among the lizards, snakes (especially within pythons) and crocodilians. The total number of embryonic heart beats between oviposition and hatching was lower in squamates than in turtles or the crocodilian. Within squamates, embryonic iguanians and gekkonids required more heartbeats to complete development than did embryos of the other squamate families that we tested. These differences plausibly reflect phylogenetic divergence in the proportion of embryogenesis completed before versus after laying. PMID:22174948
Heart rate at first postdischarge visit and outcomes in patients with heart failure.
Kim, Tae-Hun; Kim, Hyungseop; Kim, In-Cheol; Yoon, Hyuck-Jun; Park, Hyoung-Seob; Cho, Yun-Kyeong; Nam, Chang-Wook; Han, Seongwook; Hur, Seung-Ho; Kim, Yoon-Nyun
2018-07-01
Heart rate control is important to prevent adverse outcomes in patients with heart failure (HF). However, postdischarge activity may worsen heart rate control, resulting in readmission. This study aimed to explore the implications of the heart rate differences between discharge and the first outpatient visit (D-O diff). We retrospectively identified 458 patients (male: 46%; mean age: 72 years) discharged after HF. The heart rates at admission, discharge and first outpatient visit were analysed. The primary outcome was a composite of cardiovascular (CV) death and readmission of non-fatal myocardial infarction (MI), non-fatal stroke or non-fatal HF over a mean follow-up of 16 months. During follow-up, the clinical outcomes were noted in 223 patients (49%): HF, 199; stroke, 9; MI, 6; CV death, 9. The heart rate at the first outpatient visit (r=-0.311, P<0.001) and D-O diff (r=0.416, P<0.001) showed a better correlation with the time-to-clinical event than the heart rate at admission or discharge. The events group displayed a pronounced heart rate increase (13 beats/min) from discharge to the first outpatient visit compared with the event-free group (a decrease of 2 beats/min). A decrease less than -15 in the D-O diff showed a 4.5-fold risk of clinical outcomes during follow-up (P<0.001). A decreased D-O diff was related to the adverse outcomes of HF. The failure of heart rate control within more than 15 beats/min at the first outpatient visit was an independent factor for CV events. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Sato, Maki; Kanikowska, Dominika; Iwase, Satoshi; Shimizu, Yuuki; Nishimura, Naoki; Inukai, Yoko; Sato, Motohiko; Sugenoya, Junichi
2013-09-01
During the past several decades, obesity has been increasing globally. In Japan, obesity is defined by a BMI of 25 kg/m2 or over; 28.6 % of men and 20.6 % of women are obese. Obese people have an increased incidence of developing cardiovascular, renal, and hormonal diseases and sleep disorders. Obese people also have shortened sleep durations. We investigated seasonal differences in melatonin concentrations, heart rates, and heart rate variability during sleep in obese subjects in Japan. Five obese (BMI, 32.0 ± 4.9 kg/m2) and five non-obese (BMI, 23.2 ± 2.9 kg/m2) men participated in this study in the summer and winter. Electrocardiograms were measured continuously overnight in a climatic chamber at 26 °C with a relative humidity of 50 %. Saliva samples for melatonin were collected at 2300 hours, 0200 hours, and 0600 hours. We found that melatonin concentrations during sleep in obese subjects were significantly lower than those in non-obese subjects in the winter. Heart rate during sleep in winter was significantly higher than that in summer in both obese and non-obese subjects. Heart rate variability was not significantly different in the summer and winter in both obese and non-obese subjects. Our results show that decreased nocturnal melatonin concentrations during winter in obese men may be related to higher heart rates, and this may suggest that obese men are at an increased risk of a cardiovascular incident during sleep, especially in the winter.
Grosek, Stefan; Mlakar, Gorazd; Vidmar, Ivan; Ihan, Alojz; Primozic, Janez
2009-01-01
To evaluate the effect of interhospital air and ground transportation of artificially ventilated neonates on heart rate and peripheral blood leukocyte counts. Prospective, observational study. Level III multidisciplinary Neonatal and Pediatric Intensive Care Unit. Fifty-eight near-term artificially ventilated transported neonates between May 2006 and April 2007. Day-helicopter, day- and night-ground transportation. Heart rate at retrieval, on admission to the ICU and 1 h later, and peripheral blood leukocyte counts on admission and 1 d later were compared. Fifteen neonates were transported by helicopter during the daytime (D-HEL), 20 by daytime ground and 23 by nighttime ground transportation (D-GROUND, N-GROUND). No differences in delivery mode, birth weight, gestational age, gender, primary diagnoses for transportation, response time and duration of transportation were found between the groups. Similarly, no differences in pH, pCO(2), blood pressure and skin temperature at retrieval and on admission to the ICU were found between the three groups. The mean heart rate at retrieval did not differ significantly, while on arrival in the ICU and 1 h later the D-GROUND group of patients showed a significantly higher mean heart rate compared to the D-HEL and N-GROUND groups. Moreover, leukocyte counts on arrival in the ICU showed significantly higher leukocyte counts in the D-GROUND group of patients compared to the D-HEL group of patients. These results demonstrate that there is an association between daytime ground transportation and higher heart rate and peripheral blood leukocytes.
An exploration of heart rate response to differing music rhythm and tempos.
da Silva, Ariany G; Guida, Heraldo L; Antônio, Ana Márcia Dos S; Marcomini, Renata S; Fontes, Anne M G G; Carlos de Abreu, Luiz; Roque, Adriano L; Silva, Sidney B; Raimundo, Rodrigo D; Ferreira, Celso; Valenti, Vitor E
2014-05-01
The aim of this study was to investigate acute cardiac response and heart rate variability (HRV) when listening to differing forms of music. Eleven healthy men aged between 18 and 25 years old were included in the study. HRV was recorded at rest for ten minutes with no music, then were asked to listen to classical baroque or heavy metal music for a period of 20 min. It was noted that heart rate variability did not affect HRV indices for time and frequency. In conclusion, music with different tempos does not influence cardiac autonomic regulation in men. However more studies are suggested to explore this topic in greater detail. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Heart Rate Fragmentation: A Symbolic Dynamical Approach.
Costa, Madalena D; Davis, Roger B; Goldberger, Ary L
2017-01-01
Background: We recently introduced the concept of heart rate fragmentation along with a set of metrics for its quantification. The term was coined to refer to an increase in the percentage of changes in heart rate acceleration sign, a dynamical marker of a type of anomalous variability. The effort was motivated by the observation that fragmentation, which is consistent with the breakdown of the neuroautonomic-electrophysiologic control system of the sino-atrial node, could confound traditional short-term analysis of heart rate variability. Objective: The objectives of this study were to: (1) introduce a symbolic dynamical approach to the problem of quantifying heart rate fragmentation; (2) evaluate how the distribution of the different dynamical patterns ("words") varied with the participants' age in a group of healthy subjects and patients with coronary artery disease (CAD); and (3) quantify the differences in the fragmentation patterns between the two sample populations. Methods: The symbolic dynamical method employed here was based on a ternary map of the increment NN interval time series and on the analysis of the relative frequency of symbolic sequences (words) with a pre-defined set of features. We analyzed annotated, open-access Holter databases of healthy subjects and patients with CAD, provided by the University of Rochester Telemetric and Holter ECG Warehouse (THEW). Results: The degree of fragmentation was significantly higher in older individuals than in their younger counterparts. However, the fragmentation patterns were different in the two sample populations. In healthy subjects, older age was significantly associated with a higher percentage of transitions from acceleration/deceleration to zero acceleration and vice versa (termed "soft" inflection points). In patients with CAD, older age was also significantly associated with higher percentages of frank reversals in heart rate acceleration (transitions from acceleration to deceleration and vice versa , termed "hard" inflection points). Compared to healthy subjects, patients with CAD had significantly higher percentages of soft and hard inflection points, an increased percentage of words with a high degree of fragmentation and a decreased percentage of words with a lower degree of fragmentation. Conclusion: The symbolic dynamical method employed here was useful to probe the newly recognized property of heart rate fragmentation. The findings from these cross-sectional studies confirm that CAD and older age are associated with higher levels of heart rate fragmentation. Furthermore, fragmentation with healthy aging appears to be phenotypically different from fragmentation in the context of CAD.
Effects of music listening on depressed women in Taiwan.
Lai, Y M
1999-01-01
This study investigated the physiological and psychological effects of music listening on depressed women in Taiwan. Through the use of a pretest-posttest, control group, experimental design, the heart rate, respiratory rate, blood pressure, and immediate mood states before and after a music/sound intervention were measured in 30 women. Quantitative data were analyzed descriptively and with t tests. A qualitative questionnaire was administered to participants to elicit information related to the subjective experience of music/sound listening. Significant posttest differences were found in experimental group participants' heart rates, respiratory rates, blood pressure, and tranquil mood states. Significant posttest differences also were found in control group participants' heart rates and tranquil mood states. The results support the use of music listening as a body-mind healing modality for depressed women.
Deriving temperature and age appropriate heart rate centiles for children with acute infections.
Thompson, M; Harnden, A; Perera, R; Mayon-White, R; Smith, L; McLeod, D; Mant, D
2009-05-01
To describe the reference range for heart rate in children aged 3 months-10 years presenting to primary care with self-limiting infections. Cross-sectional study of children presenting to primary care with suspected acute infection. Heart rate was measured using a pulse oximeter and axillary temperature using an electronic thermometer. Centile charts of heart rates expected at given temperatures for children with self-limiting infections were calculated. Ten general practice surgeries and two out-of-hours centres in England. 1933 children presenting with suspected acute infections were recruited from in-hours general practice surgeries (1050 or 54.3%) or out-of-hours centres (883 or 45.7%). After excluding children who subsequently attended hospital and those without a final diagnosis of acute infection, 1589 children were used to create the centile charts of whom (859 or 54.1%) had upper respiratory tract infections and (215 or 13.5%) non-specific viral illness. Median, 75th, 90th and 97th centiles of heart rate at each temperature level. Heart rate increased by 9.9-14.1 bpm with each 1 degrees C increment in temperature. The 50th, 75th, 90th and 97th centiles of heart rate at each temperature level are presented graphically. Age-specific centile charts of heart rates expected at different temperatures should be used by clinicians in the initial assessment of children with acute infections. The charts will identify children who have a heart rate higher than expected for a given temperature and facilitate the interpretation of changes in heart rate on reassessment. Further research on the predictive value of the centile charts is needed to optimise their diagnostic utility.
Shaffer, Fred
2015-01-01
Heart rate variability, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operates on different time scales to adapt to environmental and psychological challenges. This article briefly reviews neural regulation of the heart and offers some new perspectives on mechanisms underlying the very low frequency rhythm of heart rate variability. Interpretation of heart rate variability rhythms in the context of health risk and physiological and psychological self-regulatory capacity assessment is discussed. The cardiovascular regulatory centers in the spinal cord and medulla integrate inputs from higher brain centers with afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. We also discuss the intrinsic cardiac nervous system and the heart-brain connection pathways, through which afferent information can influence activity in the subcortical, frontocortical, and motor cortex areas. In addition, the use of real-time HRV feedback to increase self-regulatory capacity is reviewed. We conclude that the heart's rhythms are characterized by both complexity and stability over longer time scales that reflect both physiological and psychological functional status of these internal self-regulatory systems. PMID:25694852
McCraty, Rollin; Shaffer, Fred
2015-01-01
Heart rate variability, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operates on different time scales to adapt to environmental and psychological challenges. This article briefly reviews neural regulation of the heart and offers some new perspectives on mechanisms underlying the very low frequency rhythm of heart rate variability. Interpretation of heart rate variability rhythms in the context of health risk and physiological and psychological self-regulatory capacity assessment is discussed. The cardiovascular regulatory centers in the spinal cord and medulla integrate inputs from higher brain centers with afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. We also discuss the intrinsic cardiac nervous system and the heart-brain connection pathways, through which afferent information can influence activity in the subcortical, frontocortical, and motor cortex areas. In addition, the use of real-time HRV feedback to increase self-regulatory capacity is reviewed. We conclude that the heart's rhythms are characterized by both complexity and stability over longer time scales that reflect both physiological and psychological functional status of these internal self-regulatory systems.
Hastrup, J L; Johnson, C A; Hotchkiss, A P; Kraemer, D L
1986-11-01
Fowles (1983), citing evidence from separate studies, suggests that both incentive and response cost paradigms increase heart rate and should be subsumed under Gray's (1975) 'appetitive motivational system'. Shock avoidance and loss of reward (response cost) contingencies, while aversive, appear to evoke this motivational system; consequently both should elicit heart rate increases independent of anxiety. The present investigation compared magnitude of heart rate changes observed under conditions of winning and losing money. Results showed: no differences between incentive and response cost conditions; no effect of state anxiety on heart rate in these conditions, despite an elevation of state anxiety on the task day relative to a subsequent relaxation day assessment; and some evidence for the presence under both such appetitive conditions of cardiovascular hyperresponsivity among offspring of hypertensive parents. The results suggest a need for systematic parametric studies of experimental conditions.
Mackenzie, Michael J.; Zuniga, Krystle E.; Raine, Lauren B.; Awick, Elizabeth A.; Hillman, Charles H.; Kramer, Arthur F.
2016-01-01
Abstract Background: This study examined the effects of cardiorespiratory fitness, heart rate recovery, and physical activity on working memory in breast cancer survivors and age-matched controls. Method: Using a case-control design, 32 women who had received a breast cancer diagnosis and completed primary treatment within the past 36-months (11 radiation only; 21 chemotherapy) and 30 age-matched women with no previous cancer diagnosis completed a n-back continuous performance task commonly used as an assessment of working memory. In addition, cardiorespiratory fitness and heart rate recovery were measured during a submaximal graded exercise test and physical activity was measured using 7-days of accelerometer monitoring. Results: Breast cancer survivors who had received chemotherapy had poorer heart rate recovery (p = .010) and engaged in less physical activity than women who had received radiation only (p = .004) or non-cancer controls (p = .029). Cancer treatment (radiation; chemotherapy) predicted differences in reaction times on the 1-back working memory task (p = .029). However, more rapid heart rate recovery predicted shorter reaction times on the 1-back task in the age-matched control group (p = .002). All participants with greater cardiorespiratory fitness displayed greater accuracy independent of disease status on the 1-back task (p = .017). No significant group differences in reaction times were observed for 2-back target trials between breast cancer survivors and controls. However, greater total physical activity predicted shorter reaction times in breast cancer survivors (radiation, chemotherapy) on the 2-back task (p = .014). In addition, all participants who exhibited more rapid heart rate recovery demonstrated better greater accuracy regardless of disease status (p = .013). Conclusion: These findings support differences in physical activty participation, heart rate recovery, and 1- and 2-back working memory reaction times between breast cancer survivors and age-matched controls. Greater cardiorespiratory fitness, heart rate recovery, and physical activity were positively associated with better working memory performance across conditions. PMID:26418463
Gąsior, Jakub S.; Sacha, Jerzy; Jeleń, Piotr J.; Zieliński, Jakub; Przybylski, Jacek
2016-01-01
Background: Since heart rate variability (HRV) is associated with average heart rate (HR) and respiratory rate (RespRate), alterations in these parameters may impose changes in HRV. Hence the repeatability of HRV measurements may be affected by differences in HR and RespRate. The study aimed to evaluate HRV repeatability and its association with changes in HR and RespRate. Methods: Forty healthy volunteers underwent two ECG examinations 7 days apart. Standard HRV indices were calculated from 5-min ECG recordings. The ECG-derived respiration signal was estimated to assess RespRate. To investigate HR impact on HRV, HRV parameters were corrected for prevailing HR. Results: Differences in HRV parameters between the measurements were associated with the changes in HR and RespRate. However, in multiple regression analysis only HR alteration proved to be independent determinant of the HRV differences—every change in HR by 1 bpm changed HRV values by 16.5% on average. After overall removal of HR impact on HRV, coefficients of variation of the HRV parameters significantly dropped on average by 26.8% (p < 0.001), i.e., by the same extent HRV reproducibility improved. Additionally, the HRV correction for HR decreased association between RespRate and HRV. Conclusions: In stable conditions, HR but not RespRate is the most powerful factor determining HRV reproducibility and even a minimal change of HR may considerably alter HRV. However, the removal of HR impact may significantly improve HRV repeatability. The association between HRV and RespRate seems to be, at least in part, HR dependent. PMID:27588006
Measuring task-related changes in heart rate variability.
Moses, Ziev B; Luecken, Linda J; Eason, James C
2007-01-01
Small beat-to-beat differences in heart rate are the result of dynamic control of the cardiovascular system by the sympathetic and parasympathetic nervous systems. Heart rate variability (HRV) has been positively correlated with both mental and physical health. While many studies measure HRV under rest conditions, few have measured HRV during stressful situations. We describe an experimental protocol designed to measure baseline, task, and recovery values of HRV as a function of three different types of stressors. These stressors involve an attention task, a cold pressor test, and a videotaped speech presentation. We found a measurable change in heart rate in participants (n=10) during each task (all p's < 0.05). The relative increase or decrease from pre-task heart rate was predicted by task (one-way ANOVA, p= 0.0001). Spectral analysis of HRV during the attention task revealed consistently decreased measures of both high (68+/-7%, mean+/-S.E.) and low (62+/-13%) frequency HRV components as compared to baseline. HRV spectra for the cold pressor and speech tasks revealed no consistent patterns of increase or decrease from baseline measurements. We also found no correlation in reactivity measures between any of our tasks. These findings suggest that each of the tasks in our experimental design elicits a different type of stress response in an individual. Our experimental approach may prove useful to biobehavioral researchers searching for factors that determine individual differences in responses to stress in daily life.
Thompson, Keith A; Morrissey, Ryan P; Phan, Anita; Schwarz, Ernst R
2012-08-01
To determine the effects of the US economy on heart failure hospitalization rates. The recession was associated with worsening unemployment, loss of private insurance and prescription medication benefits, medication nonadherence, and ultimately increased rates of hospitalization for heart failure. We compared hospitalization rates at a large, single, academic medical center from July 1, 2006 to February 28, 2007, a time of economic stability, and July 1, 2008 to February 28, 2009, a time of economic recession in the United States. Significantly fewer patients had private medical insurance during the economic recession than during the control period (36.5% vs 46%; P = 0.04). Despite this, there were no differences in the heart failure hospitalization or readmission rates, length of hospitalization, need for admission to an intensive care unit, in-hospital mortality, or use of guideline-recommended heart failure medications between the 2 study periods. We conclude that despite significant effects on medical insurance coverage, rates of heart failure hospitalization at our institution were not significantly affected by the recession. Additional large-scale population-based research is needed to better understand the effects of fluctuations in the US economy on heart failure hospitalization rates. © 2012 Wiley Periodicals, Inc.
[Congenital heart disease mortality in Spain during a 10 year period (2003-2012)].
Pérez-Lescure Picarzo, Javier; Mosquera González, Margarita; Latasa Zamalloa, Pello; Crespo Marcos, David
2018-05-01
Congenital heart disease is a major cause of infant mortality in developed countries. In Spain, there are no publications at national level on mortality due to congenital heart disease. The aim of this study is to analyse mortality in infants with congenital heart disease, lethality of different types of congenital heart disease, and their variation over a ten-year period. A retrospective observational study was performed to evaluate mortality rate of children under one year old with congenital heart disease, using the minimum basic data set, from 2003 to 2012. Mortality rate and relative risk of mortality were estimated by Poisson regression. There were 2,970 (4.58%) infant deaths in a population of 64,831 patients with congenital heart disease, with 73.8% of deaths occurring during first week of life. Infant mortality rate in patients with congenital heart disease was 6.23 per 10,000 live births, and remained constant during the ten-year period of the study, representing 18% of total infant mortality rate in Spain. The congenital heart diseases with highest mortality rates were hypoplastic left heart syndrome (41.4%), interruption of aortic arch (20%), and total anomalous pulmonary drainage (16.8%). Atrial septal defect (1%) and pulmonary stenosis (1.1%) showed the lowest mortality rate. Congenital heart disease was a major cause of infant mortality with no variations during the study period. The proportion of infants who died in our study was similar to other similar countries. In spite of current medical advances, some forms of congenital heart disease show very high mortality rates. Copyright © 2017 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Beckers, Paul J; Possemiers, Nadine M; Van Craenenbroeck, Emeline M; Van Berendoncks, An M; Wuyts, Kurt; Vrints, Christiaan J; Conraads, Viviane M
2012-02-01
Exercise training efficiently improves peak oxygen uptake (V˙O2peak) in patients with chronic heart failure. To optimize training-derived benefit, higher exercise intensities are being explored. The correct identification of anaerobic threshold is important to allow safe and effective exercise prescription. During 48 cardiopulmonary exercise tests obtained in patients with chronic heart failure (59.6 ± 11 yrs; left ventricular ejection fraction, 27.9% ± 9%), ventilatory gas analysis findings and lactate measurements were collected. Three technicians independently determined the respiratory compensation point (RCP), the heart rate turning point (HRTP) and the second lactate turning point (LTP2). Thereafter, exercise intensity (target heart rate and workload) was calculated and compared between the three methods applied. Patients had significantly reduced maximal exercise capacity (68% ± 21% of predicted V˙O2peak) and chronotropic incompetence (74% ± 7% of predicted peak heart rate). Heart rate, workload, and V˙O2 at HRTP and at RCP were not different, but at LTP2, these parameters were significantly (P < 0.0001) higher. Mean target heart rate and target workload calculated using the LTP2 were 5% and 12% higher compared with those calculated using HRTP and RCP, respectively. The calculation of target heart rate based on LTP2 was 5% and 10% higher in 12 of 48 (25%) and 6 of 48 (12.5%) patients, respectively, compared with the other two methods. In patients with chronic heart failure, RCP and HRTP, determined during cardiopulmonary exercise tests, precede the occurrence of LTP2. Target heart rates and workloads used to prescribe tailored exercise training in patients with chronic heart failure based on LTP2 are significantly higher than those derived from HRTP and RCP.
De Tommasi, Elisabetta; Iacoviello, Massimo; Romito, Roberta; Ceconi, Claudio; Guida, Pietro; Massari, Francesco; Francolini, Gloria; Bertocchi, Federico; Ferrari, Roberto; Rizzon, Paolo; Pitzalis, Maria Vittoria
2003-11-01
In chronic heart failure (CHF), the derangement of autonomic nervous system activity has a deep impact on the progression of the disease. It has been demonstrated that modulation of the renin-angiotensin aldosterone system (RAAS) increases autonomic control of heart rate and reduces adrenergic activity. We sought to evaluate, in CHF, the different effects of an ACE inhibitor (lisinopril) and of an AT1 receptor antagonist (valsartan) on heart rate variability, baroreflex sensitivity and norepinephrine plasma levels. Ninety patients (61 +/- 10 years, 2.3 +/- 0.5, New York Heart Association class) with CHF and left ventricular ejection fraction <40% were randomly assigned in a double-blind fashion to receive lisinopril (uptitrated to 20 mg/d) or valsartan (uptitrated to 160 mg/d) therapy for 16 weeks. Heart rate variability (evaluated by measuring standard deviation of normal R-R intervals on 24-hour ECG recordings), spontaneous baroreflex sensitivity and aldosterone and norepinephrine plasma levels were assessed before and after drug therapy. There were no significant differences between valsartan and lisinopril in their effects on left ventricular function, arterial pressure, aldosterone plasma levels and autonomic control of heart rate. Both lisinopril and valsartan significantly reduced plasma norepinephrine levels, but the reduction induced by valsartan was significantly greater than that observed for lisinopril (27% vs 6%, P <.05). This study shows a comparable effect of ACE inhibition (lisinopril) and of AT1 receptor antagonism (valsartan) on cardiac vagal control of heart rate, whereas valsartan has shown a more effective modulation of sympathetic activity measured by plasma norepinephrine levels.
Universal design of a microcontroller and IoT system to detect the heart rate
NASA Astrophysics Data System (ADS)
Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar
2017-11-01
Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).
Murtazina, E P
2015-01-01
Investigation of the processes of studying human instructions relevant follow-up in terms of systemic mechanisms of learning and memory processes, and moreover affects such a fundamental issue as psychophysiology focused attention, understanding the meaning of the information provided and the formation of social motivation in human activities. Analysis of heart rate variability in reading the instructions compared to the initial state of operational rest showed that this stage of the activity causes pronounced emotional stress, which is manifested in increased heart rate, decrease in variability and pronounced changes in the spectral characteristics of heart rate. Besides, it was revealed that heart rate variability in a state of operational rest before testing, and in the process of reading instructions positively correlated with the duration of the instruction reading and inversely correlated with effectiveness and the level of resistance of the subjects to the error after error when follow-up activities. Showing pronounced gender differences in the relationships between changes in the variability of heart rate when reading the instructions and the subsequent execution indicators of visual-motor test.
Caffeine Consumption and Heart Rate and Blood Pressure Response to Regadenoson
Bitar, Abbas; Mastouri, Ronald; Kreutz, Rolf P.
2015-01-01
Background Current guidelines recommend that caffeinated products should be avoided for at least 12 hours prior to regadenoson administration. We intended to examine the effect of caffeine consumption and of timing of last dose on hemodynamic effects after regadenoson administration for cardiac stress testing. Methods 332 subjects undergoing regadenoson stress testing were enrolled. Baseline characteristics, habits of coffee/caffeine exposure, baseline vital signs and change in heart rate, blood pressure, percent of maximal predicted heart rate, and percent change in heart rate were prospectively collected. Results Non-coffee drinkers (group 1) (73 subjects) and subjects who last drank coffee >24 hours (group 3) (139 subjects) prior to regadenoson did not demonstrate any difference in systolic blood pressure, heart rate change, maximal predicted heart rate and percent change in heart rate. Systolic blood pressure change (15.2±17.1 vs. 7.2±10.2 mmHg, p = 0.001), heart rate change (32.2±14 vs. 27.3±9.6 bpm, p = 0.038) and maximal predicted heart rate (65.5±15.6 vs. 60.7±8.6%, p = 0.038) were significantly higher in non-coffee drinkers (group 1) compared to those who drank coffee 12–24 hours prior (group 2) (108 subjects). Subjects who drank coffee >24 hours prior (group 3) exhibited higher systolic blood pressure change (13±15.8 vs. 7±10.2, p = 0.007), and heart rate change (32.1±15.3 vs. 27.3±9.6, p = 0.017) as compared to those who drank coffee 12–24 hours prior to testing (group 2). Conclusions Caffeine exposure 12–24 hours prior to regadenoson administration attenuates the vasoactive effects of regadenoson, as evidenced by a blunted rise in heart rate and systolic blood pressure. These results suggest that caffeine exposure within 24 hours may reduce the effects of regadenoson administered for vasodilatory cardiac stress testing. PMID:26098883
Idiosyncratic heart rate response in men during sexual arousal.
Rowland, David L; Crawford, Sara B
2011-05-01
Heart rate, sensitive to sympathetic activation, is known to change during sexual arousal and therefore may be a useful tool for investigating psychosomatic differences between sexually functional and dysfunctional men. However, heart rate during arousal also tends to be highly variable across individual men, making its predictability based on group patterns relatively poor. We wanted to determine whether individual men show idiosyncratic heart rate patterns during sexual arousal, that is, whether they exhibit consistent patterns across similar (though not identical) stimulus situations. Agreement between heart rates under the two conditions, visual sexual stimulation (VSS) and VSS + vibrotactile (VIB), was assessed using the concordance correlation coefficient (CCC). Thirty-eight men, 25 of whom were diagnosed with premature ejaculation (PE), were monitored for penile response and heart rate under two similar (though not identical) conditions: a 9-minute erotic video (VSS), then a 9-minute erotic video combined with vibrotactile penile stimulation (VSS + VIB). CCC for men with PE was 0.65; for the sexually functional comparison group, CCC was 0.82. For both groups combined, CCC was 0.71. For all groupings, the CCC was relatively high, indicating agreement in heart rate from one session to the next within individual men. Despite high intersubject variation in heart rate patterns, individual men show signature heart rates across similar sexual stimulus sessions. Such stereotypy helps explain previous inconsistent findings and may also serve as a marker for the effectiveness of treatments designed to improve ejaculatory control in men with PE. © 2011 International Society for Sexual Medicine.
Estimating energy expenditure from heart rate in older adults: a case for calibration.
Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi
2014-01-01
Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.
NASA Astrophysics Data System (ADS)
Dey, Shibaji Ch.; Dey, Netai Chandra; Sharma, Gourab Dhara
2018-04-01
Indian underground mining (UGM) transport system largely deals with different fore and back bearing work processes associated with different occupational disorders and fatigue related work stress disorders (FRWSDs). Therefore, this research study is specifically aimed to determine the fatigue related problems in general and determination of Recovery Heart Rate (Rec HR) pattern and exact cause of FRWSDs in particular. A group of twenty (N = 20) UGM operators are selected for the study. Heart rate profiles and work intensities of selected workforces have been recorded continuously during their regular mine operation and the same workforces are tested on a treadmill on surface with almost same work intensity (%Maximal Heart Rate) which was earlier observed in the mine. Recovery Heart Rate (Rec HR) in both the experiment zones is recorded. It is observed that with almost same work intensity, the recovery patterns of submaximal prolonged work in mine are different as compared to treadmill. This research study indicates that non-biomechanical muscle activity along with environmental stressors may have an influence on recovery pattern and FRWSDs.
ERIC Educational Resources Information Center
Monk, Catherine; Sloan, Richard P.; Myers, Michael M.; Ellman, Lauren; Werner, Elizabeth; Jeon, Jiyeon; Tager, Felice; Fifer, William P.
2004-01-01
Objective: To determine whether there are differences in fetal heart rate (FHR) reactivity associated with women's psychiatric status. Method: In 57 women in their 36th to 38th week of pregnancy (mean age 27 [+ or -] 6 years), electrocardiogram, blood pressure (BP), respiration (RSP), and FHR were measured during baseline and a psychological…
Namdar, Hossein; Taban Sadeghi, Mohammadreza; Sabourimoghaddam, Hassan; Sadeghi, Babak; Ezzati, Davoud
2014-01-01
The present research investigated the effects of two different types of music on cardiovascular responses in essential hypertensive men in comparison with healthy men based on introversion and extraversion. One hundred and thirteen hypertensive men referred to Madani Heart Hospital in Tabriz completed the NEO-FFI Questionnaire and after obtaining acceptable scores were classified in four groups: introvert patients, extravert patients, introvert healthy subjects, and extravert healthy subjects (each group with 25 samples with age range 31-50). Baseline blood pressure and heart rate of each subject was recorded without any stimulus. Then subjects were exposed to slow-beat music and blood pressure and heart rate were recorded. After15 minute break, and a little cognitive task for distraction, subjects were exposed to fast-beat music and blood pressure and heart rate were recorded again. Multivariate analysis of covariance (MANCOVA) test showed that extravert patient subjects obtained greater reduction in systolic blood pressure and heart rate after presenting slow-beat music compared with introvert patients (P= 0.035, and P= 0.033 respectively). And extravert healthy subjects obtained greater reduction in heart rate after presenting slow-beat music compared with introvert healthy subjects (P= 0.036). However, there are no significant differences between introvert and extravert groups in systolic and diastolic blood pressure and heart rate after presenting fast-beat music. Based on our results, introvert subjects experience negative emotions more than extravert subjects and negative emotions cause less change in blood pressure in these subjects compared with extravert subjects.
Namdar, Hossein; Taban Sadeghi, Mohammadreza; Sabourimoghaddam, Hassan; Sadeghi, Babak; Ezzati, Davoud
2014-01-01
Introduction: The present research investigated the effects of two different types of music on cardiovascular responses in essential hypertensive men in comparison with healthy men based on introversion and extraversion. Methods: One hundred and thirteen hypertensive men referred to Madani Heart Hospital in Tabriz completed the NEO-FFI Questionnaire and after obtaining acceptable scores were classified in four groups: introvert patients, extravert patients, introvert healthy subjects, and extravert healthy subjects (each group with 25 samples with age range 31-50). Baseline blood pressure and heart rate of each subject was recorded without any stimulus. Then subjects were exposed to slow-beat music and blood pressure and heart rate were recorded. After15 minute break, and a little cognitive task for distraction, subjects were exposed to fast-beat music and blood pressure and heart rate were recorded again. Results: Multivariate analysis of covariance (MANCOVA) test showed that extravert patient subjects obtained greater reduction in systolic blood pressure and heart rate after presenting slow-beat music compared with introvert patients (P= 0.035, and P= 0.033 respectively). And extravert healthy subjects obtained greater reduction in heart rate after presenting slow-beat music compared with introvert healthy subjects (P= 0.036). However, there are no significant differences between introvert and extravert groups in systolic and diastolic blood pressure and heart rate after presenting fast-beat music. Conclusion: Based on our results, introvert subjects experience negative emotions more than extravert subjects and negative emotions cause less change in blood pressure in these subjects compared with extravert subjects. PMID:25320667
Musicant, Oren; Botzer, Assaf; Laufer, Ilan; Collet, Christian
2018-05-01
Objective To study the relationship between physiological indices and kinematic indices during braking events of different intensities. Background Based on mental workload theory, driving and other task demands may generate changes in physiological indices, such as the driver's heart rate and skin conductance. However, no attempts were made to associate changes in physiological indices with changes in vehicle kinematics that result from the driver attempts to meet task demands. Method Twenty-five drivers participated in a field experiment. We manipulated braking demands using roadside signs to communicate the speed (km/h) before braking (50 or 60) and the target speed for braking (30 or to a complete stop). In an additional session, we asked drivers to brake as if they were responding to an impending collision. We analyzed the relationship between the intensities of braking events as measured by deceleration values (g) and changes in heart rate, heart rate variability, and skin conductance. Results All physiological indices were associated with deceleration intensity. Especially salient were the differences in physiological indices between the intensive (|g| > 0.5) and nonintensive braking events. The strongest relationship was between braking intensity and skin conductance. Conclusions Skin conductance, heart rate, and heart rate variability can mirror the mental workload elicited by varying braking intensities. Application Associating vehicle kinematics with physiological indices related to short-term driving events may help improve the performance of driver assistance systems.
Baker, Jacquie; Racosta, Juan M; Balint, Brittany; Kimpinski, Kurt
2018-03-01
The clinical significance of heart rate variability in the context of autonomic dysfunction continues to be a matter of debate. A consensus is lacking on the best heart rate variability measures for clinical purposes. Therefore, the purpose of this study was to investigate the utility of heart rate variability parameters in healthy versus autonomic dysfunction. Healthy young (n = 134), healthy older (n = 32), and patients with mild (postural tachycardia syndrome; n = 25) and severe (neurogenic orthostatic hypotension; n = 34) autonomic dysfunction were included. Time and frequency parameters during baseline, head-up tilt (HUT), and heart rate response to deep breathing (HRDB) were compared. Cardiovagal time parameters were significantly reduced during HUT in healthy young and postural tachycardia syndrome (P < 0.001). Healthy young had significantly higher time parameters during baseline, HUT, and HRDB (P < 0.01). This was reflected by a significantly lower resting heart rate (HR) (61.4 ± 9.0 bpm vs. 76.8 ± 13.6 bpm; P < 0.001) and a smaller [INCREMENT]HR during HUT (32.8 ± 10.5 bpm vs. 44.4 ± 13.3 bpm; P < 0.001). Time parameters increased in young and postural tachycardia syndrome during HRDB, which was characterized by a nonsignificant difference in [INCREMENT]HR between both groups. Time parameters were significantly higher in healthy old versus neurogenic orthostatic hypotension at rest and during HRDB (P < 0.05). During HUT, only the SD of all normal RR intervals remained significantly higher. Heart rate changes corroborated these findings. Resting HR was significantly lower in healthy older (62.6 ± 11.0 bpm vs. 70.7 ± 12.4 bpm), and [INCREMENT]HR during HRDB was significantly higher (15.9 ± 9.2 bpm vs. 3.9 ± 4.2 bpm; P < 0.001). During HUT, [INCREMENT]HR showed no significant differences. Time domain parameters of heart rate variability have a greater utility than frequency parameters in clinical autonomic disorders.
Does respiratory sinus arrhythmia occur in fishes?
Campbell, Hamish A; Taylor, Edwin W; Egginton, Stuart
2005-01-01
The hypothesis that respiratory modulation of heart rate variability (HRV) or respiratory sinus arrhythmia (RSA) is restricted to mammals was tested on four Antarctic and four sub-Antarctic species of fish, that shared close genotypic or ecotypic similarities but, due to their different environmental temperatures, faced vastly different selection pressures related to oxygen supply. The intrinsic heart rate (fH) for all the fish species studied was ∼25% greater than respiration rate (fV), but vagal activity successively delayed heart beats, producing a resting fH that was synchronized with fV in a progressive manner. Power spectral statistics showed that these episodes of relative bradycardia occurred in a cyclical manner every 2–4 heart beats in temperate species but at >4 heart beats in Antarctic species, indicating a more relaxed selection pressure for cardio-respiratory coupling. This evidence that vagally mediated control of fH operates around the ventilatory cycle in fish demonstrates that influences similar to those controlling RSA in mammals operate in non-mammalian vertebrates. PMID:17148239
Girotra, Saket; Kitzman, Dalane W.; Kop, Willem J.; Stein, Phyllis K.; Gottdiener, John S.; Mukamal, Kenneth J.
2012-01-01
OBJECTIVES To determine the relationship between heart rate response during low-grade physical exertion (six-minute walk) with mortality and adverse cardiovascular outcomes in the elderly. METHODS Participants in the Cardiovascular Health Study, who completed a six-minute walk test, were included. We used delta heart rate (difference between post-walk heart rate and resting heart rate) as a measure of chronotropic response and examined its association with 1) all-cause mortality and 2) incident coronary heart disease (CHD) event, using multivariable Cox regression models. RESULTS We included 2224 participants (mean age 77±4 years; 60% women, 85% white). The average delta heart rate was 26 beats/min. Participants in the lowest tertile of delta heart rate (<20 beats/min) had higher risk-adjusted mortality (hazard ratio [HR] 1.18; 95% confidence interval [CI][1.00, 1.40]) and incident CHD (HR 1.37; 95% CI[1.05, 1.78]) compared to subjects in the highest tertile (≥30 beats/min), with a significant linear trend across tertiles (P for trend <0.05 for both outcomes). This relationship was not significant after adjustment for distance walked. CONCLUSION Impaired chronotropic response during six-minute walk test was associated with an increased risk of mortality and incident CHD among the elderly. This association was attenuated after adjusting for distance walked. PMID:22722364
Watanabe, Hiroyuki; Miyazaki, Hiroyasu
2006-01-01
Over- and/or under-correction of QT intervals for changes in heart rate may lead to misleading conclusions and/or masking the potential of a drug to prolong the QT interval. This study examines a nonparametric regression model (Loess Smoother) to adjust the QT interval for differences in heart rate, with an improved fitness over a wide range of heart rates. 240 sets of (QT, RR) observations collected from each of 8 conscious and non-treated beagle dogs were used as the materials for investigation. The fitness of the nonparametric regression model to the QT-RR relationship was compared with four models (individual linear regression, common linear regression, and Bazett's and Fridericia's correlation models) with reference to Akaike's Information Criterion (AIC). Residuals were visually assessed. The bias-corrected AIC of the nonparametric regression model was the best of the models examined in this study. Although the parametric models did not fit, the nonparametric regression model improved the fitting at both fast and slow heart rates. The nonparametric regression model is the more flexible method compared with the parametric method. The mathematical fit for linear regression models was unsatisfactory at both fast and slow heart rates, while the nonparametric regression model showed significant improvement at all heart rates in beagle dogs.
Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.
Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel
2018-03-01
Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).
South Asian people and heart disease: an assessment of the importance of socioeconomic position.
Nazroo, J Y
2001-01-01
Higher rates of mortality from ischemic heart disease among South Asian people are well established and appear to be unrelated to socioeconomic position. However, traditional indicators of socioeconomic position may be inadequate when making comparisons across ethnic groups. This study investigates these issues in a British morbidity survey. The Fourth National Survey was a British cross-sectional study conducted from 1993 to 1994. The study used a national representative community sample, consisting of 2867 white respondents, 2001 Indian respondents, and 1776 Pakistani and Bangladeshi respondents. Data on occupational class and standard of living were used to examine the contribution of socioeconomic factors to differences in rates of reported severe chest pain and diagnosed heart disease. White and Indian respondents had similar rates of reported indicators of heart disease, while Pakistani and Bangladeshi respondents had rates that were considerably higher. There was a clear socioeconomic gradient in reported heart disease for each ethnic group, with those who were poorer having higher rates. Controlling for occupational class made little difference to the greater risk of heart disease found in the Pakistani and Bangladeshi group; however, controlling for a more sensitive indicator of socioeconomic position-standard of living-greatly reduced their disproportionate risk. The findings suggest that South Asian people do not share a uniformly greater risk of heart disease. The more economically advantaged South Asian group, Indians, had rates that are similar to those found among white people, while the poorest groups, Pakistanis and Bangladeshis, had rates that are considerably higher. Socioeconomic position predicted risk in each ethnic group and made a key contribution to the higher risk found for Pakistani and Bangladeshi individuals. Other studies may have failed to identify the important contribution of socioeconomic position because the indicators used were too crude.
Mather, Mara; Joo Yoo, Hyun; Clewett, David V; Lee, Tae-Ho; Greening, Steven G; Ponzio, Allison; Min, Jungwon; Thayer, Julian F
2017-04-15
The locus coeruleus (LC) is a key node of the sympathetic nervous system and suppresses parasympathetic activity that would otherwise increase heart rate variability. In the current study, we examined whether LC-MRI contrast reflecting neuromelanin accumulation in the LC was associated with high-frequency heart rate variability (HF-HRV), a measure reflecting parasympathetic influences on the heart. Recent evidence indicates that neuromelanin, a byproduct of catecholamine metabolism, accumulates in the LC through young and mid adulthood, suggesting that LC-MRI contrast may be a useful biomarker of individual differences in habitual LC activation. We found that, across younger and older adults, greater LC-MRI contrast was negatively associated with HF-HRV during fear conditioning and spatial detection tasks. This correlation was not accounted for by individual differences in age or anxiety. These findings indicate that individual differences in LC structure relate to key cardiovascular parameters. Copyright © 2017 Elsevier Inc. All rights reserved.
Scheer, Krista S; Siebrant, Sarah M; Brown, Gregory A; Shaw, Brandon S; Shaw, Ina
Nintendo Wii, Sony Playstation Move , and Microsoft XBOX Kinect are home video gaming systems that involve player movement to control on-screen game play. Numerous investigations have demonstrated that playing Wii is moderate physical activity at best, but Move and Kinect have not been as thoroughly investigated. The purpose of this study was to compare heart rate, oxygen consumption, and ventilation while playing the games Wii Boxing, Kinect Boxing, and Move Gladiatorial Combat. Heart rate, oxygen consumption, and ventilation were measured at rest and during a graded exercise test in 10 males and 9 females (19.8 ± 0.33 y, 175.4 ± 2.0 cm, 80.2 ± 7.7 kg,). On another day, in a randomized order, the participants played Wii Boxing, K inect Boxing, and Move Gladiatorial Combat while heart rate, ventilation, and oxygen consumption were measured. There were no differences in heart rate (116.0 ± 18.3 vs. 119.3 ± 17.6 vs. 120.1 ± 17.6 beats/min), oxygen consumption (9.2 ± 3.0 vs. 10.6 ± 2.4 vs. 9.6 ± 2.4 ml/kg/min), or minute ventilation (18.9 ± 5.7 vs. 20.8 ± 8.0 vs. 19.7 ± 6.4 L/min) when playing Wii boxing, Kinect boxing, or Move Gladiatorial Combat (respectively). Playing Nintendo Wii Boxing, XBOX Kinect Boxing, and Sony PlayStation Move Gladiatorial Combat all increase heart rate, oxygen consumption, and ventilation above resting levels but there were no significant differences between gaming systems. Overall, playing a "physically active" home video game system does not meet the minimal threshold for moderate intensity physical activity, regardless of gaming system.
SCHEER, KRISTA S.; SIEBRANT, SARAH M.; BROWN, GREGORY A.; SHAW, BRANDON S.; SHAW, INA
2014-01-01
Nintendo Wii, Sony Playstation Move, and Microsoft XBOX Kinect are home video gaming systems that involve player movement to control on-screen game play. Numerous investigations have demonstrated that playing Wii is moderate physical activity at best, but Move and Kinect have not been as thoroughly investigated. The purpose of this study was to compare heart rate, oxygen consumption, and ventilation while playing the games Wii Boxing, Kinect Boxing, and Move Gladiatorial Combat. Heart rate, oxygen consumption, and ventilation were measured at rest and during a graded exercise test in 10 males and 9 females (19.8 ± 0.33 y, 175.4 ± 2.0 cm, 80.2 ± 7.7 kg,). On another day, in a randomized order, the participants played Wii Boxing, Kinect Boxing, and Move Gladiatorial Combat while heart rate, ventilation, and oxygen consumption were measured. There were no differences in heart rate (116.0 ± 18.3 vs. 119.3 ± 17.6 vs. 120.1 ± 17.6 beats/min), oxygen consumption (9.2 ± 3.0 vs. 10.6 ± 2.4 vs. 9.6 ± 2.4 ml/kg/min), or minute ventilation (18.9 ± 5.7 vs. 20.8 ± 8.0 vs. 19.7 ± 6.4 L/min) when playing Wii boxing, Kinect boxing, or Move Gladiatorial Combat (respectively). Playing Nintendo Wii Boxing, XBOX Kinect Boxing, and Sony PlayStation Move Gladiatorial Combat all increase heart rate, oxygen consumption, and ventilation above resting levels but there were no significant differences between gaming systems. Overall, playing a “physically active” home video game system does not meet the minimal threshold for moderate intensity physical activity, regardless of gaming system. PMID:27182399
Seebacher, Frank; Franklin, Craig E
2007-11-01
Changes in blood flow are a principal mechanism of thermoregulation in vertebrates. Changes in heart rate will alter blood flow, although multiple demands for limited cardiac output may compromise effective thermoregulation. We tested the hypothesis that regional differences in blood flow during heating and cooling can occur independently from changes in heart rate. We measured heart rate and blood pressure concurrently with blood flow in the crocodile, Crocodylus porosus. We measured changes in blood flow by laser Doppler flowmetry, and by injecting coloured microspheres. All measurements were made under different heat loads, with and without blocking cholinergic and beta-adrenergic receptors (autonomic blockade). Heart rates were significantly faster during heating than cooling in the control animals, but not when autonomic receptors were blocked. There were no significant differences in blood flow distribution between the control and autonomic blockade treatments. In both treatments, blood flow was directed to the dorsal skin and muscle and away from the tail and duodenum during heating. When the heat source was switched off, there was a redistribution of blood from the dorsal surface to the duodenum. Blood flow to the leg skin and muscle, and to the liver did not change significantly with thermal state. Blood pressure was significantly higher during the autonomic blockade than during the control. Thermal time constants of heating and cooling were unaffected by the blockade of autonomic receptors. We concluded that animals partially compensated for a lack of differential heart rates during heating and cooling by redistributing blood within the body, and by increasing blood pressure to increase flow. Hence, measures of heart rate alone are insufficient to assess physiological thermoregulation in reptiles.
Three Weeks of Overload Training Increases Resting Muscle Sympathetic Activity.
Coates, Alexandra M; Incognito, Anthony V; Seed, Jeremy D; Doherty, Connor J; Millar, Philip J; Burr, Jamie F
2018-05-01
Overload training is hypothesized to alter autonomic regulation, although interpretations using indirect measures of heart rate variability are conflicting. The aim of the present study was to examine the effects of overload training on muscle sympathetic nerve activity (MSNA), a direct measure of central sympathetic outflow, in recreational endurance athletes. Measurements of heart rate variability, cardiac baroreflex sensitivity (BRS), MSNA (microneurography), and sympathetic BRS were obtained in 17 healthy triathletes and cyclists after 1 wk of reduced training (baseline) and again after 3 wk of either regular (n = 7) or overload (n = 10) training. After training, the changes (Δ) in peak power output (10 ± 10 vs -12 ± 9 W, P < 0.001), maximal heart rate (-2 ± 4 vs -8 ± 3 bpm, P = 0.006), heart rate variability (SD of normal-to-normal intervals, 27 ± 31 vs -3 ± 25 ms; P = 0.04), and cardiac BRS (7 ± 6 vs -2 ± 8 ms·mm Hg, P = 0.02) differed between the control and overload groups. The change in MSNA burst frequency (-2 ± 2 vs 4 ± 5 bursts per minute, P = 0.02) differed between groups. Across all participants, the changes in resting MSNA and peak power output were correlated negatively (r = -0.51, P = 0.04). No between-group differences in resting heart rate or blood pressure were observed (all P > 0.05). Overload training increased MSNA and attenuated increases in cardiac BRS and heart rate variability observed with regular training. These results support neural adaptations after overload training and suggest that increased central sympathetic outflow may be linked with decreased exercise performance.
Murray, Joseph; Hallal, Pedro C; Mielke, Gregore I; Raine, Adrian; Wehrmeister, Fernando C; Anselmi, Luciana; Barros, Fernando C
2016-01-01
Abstract Background : Youth violence is a major global public health problem. Three UK and Swedish studies suggest that low resting heart rate predicts male youth violence, but this has not been tested in other social settings nor for females. Methods : A prospective, population-based birth cohort study was conducted in Pelotas, Brazil. Heart rate was measured using a wrist monitor at ages 11, 15 and 18 years. Violent crime and non-violent crime were measured at age 18 in self-reports and official records ( N = 3618). Confounding variables were assessed in the perinatal period and at age 11, in interviews with mothers and children. Logistic regression was used to estimate associations between quartiles of heart rate at each age, and violent and non-violent crime at age 18, separately for males and females. Results : Lower resting heart rate was a robust correlate of violent and non-violent crime for males. Comparing males in the lowest and top quartiles of heart rate at age 15 years, adjusted odds ratios were 1.9 for violent crime [95% confidence interval (CI) 1.4–2.7] and 1.7 for non-violent crime (95% CI 1.1–2.6). For females, crime outcomes were associated only with low resting heart rate at age 18. Associations were generally linear across the four heart rate quartiles. There was no evidence that associations differed according to socioeconomic status at age 15. Conclusions : Low resting heart rate predicted violent and non-violent crime for males, and was cross-sectionally associated with crime for females. Biological factors may contribute to individual propensity to commit crime, even in a middle-income setting with high rates of violence. PMID:26822937
A pilot randomized controlled trial of EKG for neonatal resuscitation
Katheria, Anup; Arnell, Kathy; Brown, Melissa; Hassen, Kasim; Maldonado, Mauricio; Finer, Neil
2017-01-01
Background The seventh edition of the American Academy of Pediatrics Neonatal Resuscitation Program recommends the use of a cardiac monitor in infants that need resuscitation. Previous trials have shown that EKG heart rate is available before pulse rate from a pulse oximeter. To date no trial has looked at how the availability of electrocardiogram (EKG) affects clinical interventions in the delivery room. Objective To determine whether the availability of an EKG heart rate value and tracing to the clinical team has an effect on physiologic measures and related interventions during the stabilization of preterm infants. Design/Methods Forty (40) premature infants enrolled in a neuro-monitoring study (The Neu-Prem Trial: NCT02605733) who had an EKG monitor available were randomized to have the heart rate information from the bedside EKG monitor either displayed or not displayed to the clinical team. Heart rate, oxygen saturation, FiO2 and mean airway pressure from a data acquisition system were recorded every 2 seconds. Results were averaged over 30 seconds and the differences analyzed using two-tailed t-test. Interventions analyzed included time to first change in FiO2, first positive pressure ventilation, first increase in airway pressure, and first intubation. Results There were no significant differences in time to clinical interventions between the blinded and unblinded group, despite the unblinded group having access to a visible heart rate at 66 +/- 20 compared to 114 +/- 39 seconds for the blinded group (p < .0001). Pulse rate from oximeter was lower than EKG heart rate during the first 2 minutes of life, but this was not significant. Conclusion(s) EKG provides an earlier, and more accurate heart rate than pulse rate from an oximeter during stabilization of preterm infants, allowing earlier intervention. All interventions were started earlier in the unblinded EKG group but these numbers were not significant in this small trial. Earlier EKG placement before pulse oximeter placement may affect other interventions, but this needs further study. PMID:29099872
Kaese, Sven; Bögeholz, Nils; Pauls, Paul; Dechering, Dirk; Olligs, Jan; Kölker, Katharina; Badawi, Sascha; Frommeyer, Gerrit; Pott, Christian; Eckardt, Lars
2017-08-01
The cardiac sodium/calcium (Na + /Ca 2+ ) exchanger (NCX) contributes to diastolic depolarization in cardiac pacemaker cells. Increased NCX activity has been found in heart failure and atrial fibrillation. The influence of increased NCX activity on resting heart rate, beta-adrenergic-mediated increase in heart rate, and cardiac conduction properties is unknown. The purpose of this study was to investigate the influence of NCX overexpression in a homozygous transgenic whole-heart mouse model (NCX-OE) on sinus and AV nodal function. Langendorff-perfused, beating whole hearts of NCX-OE and the corresponding wild-type (WT) were studied ± isoproterenol (ISO; 0.2 μM). Epicardial ECG, AV nodal Wenckebach cycle length (AVN-WCL), and retrograde AVN-WCL were obtained. At baseline, basal heart rate was unaltered between NCX-OE and WT (WT: cycle length [CL] 177.6 ± 40.0 ms, no. of hearts [n] = 20; NCX-OE: CL 185.9 ± 30.5 ms, n = 18; P = .21). In the presence of ISO, NCX-OE exhibited a significantly higher heart rate compared to WT (WT: CL 133.4 ± 13.4 ms, n = 20; NCX-OE: CL 117.7 ± 14.2 ms, n = 18; P <.001). ISO led to a significant shortening of the anterograde and retrograde AVN-WCL without differences between NCX-OE and WT. This study is the first to demonstrate that increased NCX activity enhances beta-adrenergic increase of heart rate. Mechanistically, increased NCX inward mode activity may promote acceleration of diastolic depolarization in sinus nodal pacemaker cells, thus enhancing chronotropy in NCX-OE. These findings suggest a novel potential therapeutic target for heart rate control in the presence of increased NCX activity, such as heart failure. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Sex differences in the fetal heart rate variability indices of twins.
Tendais, Iva; Figueiredo, Bárbara; Gonçalves, Hernâni; Bernardes, João; Ayres-de-Campos, Diogo; Montenegro, Nuno
2015-03-01
To evaluate the differences in linear and complex heart rate dynamics in twin pairs according to fetal sex combination [male-female (MF), male-male (MM), and female-female (FF)]. Fourteen twin pairs (6 MF, 3 MM, and 5 FF) were monitored between 31 and 36.4 weeks of gestation. Twenty-six fetal heart rate (FHR) recordings of both twins were simultaneously acquired and analyzed with a system for computerized analysis of cardiotocograms. Linear and nonlinear FHR indices were calculated. Overall, MM twins presented higher intrapair average in linear indices than the other pairs, whereas FF twins showed higher sympathetic-vagal balance. MF twins exhibited higher intrapair average in entropy indices and MM twins presented lower entropy values than FF twins considering the (automatically selected) threshold rLu. MM twin pairs showed higher intrapair differences in linear heart rate indices than MF and FF twins, whereas FF twins exhibited lower intrapair differences in entropy indices. The results of this exploratory study suggest that twins have sex-specific differences in linear and nonlinear indices of FHR. MM twins expressed signs of a more active autonomic nervous system and MF twins showed the most active complexity control system. These results suggest that fetal sex combination should be taken into consideration when performing detailed evaluation of the FHR in twins.
Practical remarks on the heart rate and saturation measurement methodology
NASA Astrophysics Data System (ADS)
Kowal, M.; Kubal, S.; Piotrowski, P.; Staniec, K.
2017-05-01
A surface reflection-based method for measuring heart rate and saturation has been introduced as one having a significant advantage over legacy methods in that it lends itself for use in special applications such as those where a person’s mobility is of prime importance (e.g. during a miner’s work) and excluding the use of traditional clips. Then, a complete ATmega1281-based microcontroller platform has been described for performing computational tasks of signal processing and wireless transmission. In the next section remarks have been provided regarding the basic signal processing rules beginning with raw voltage samples of converted optical signals, their acquisition, storage and smoothing. This chapter ends with practical remarks demonstrating an exponential dependence between the minimum measurable heart rate and the readout resolution at different sampling frequencies for different cases of averaging depth (in bits). The following section is devoted strictly to the heart rate and hemoglobin oxygenation (saturation) measurement with the use of the presented platform, referenced to measurements obtained with a stationary certified pulsoxymeter.
Pittig, Andre; Arch, Joanna J; Lam, Chi W R; Craske, Michelle G
2013-01-01
It remains unclear if diminished high frequency heart rate variability (HF-HRV) can be found across anxiety disorders. HF-HRV and heart rate (HR) were examined in panic (PD), generalized anxiety (GAD), social anxiety (SAD), and obsessive-compulsive disorder (OCD) relative to healthy controls at baseline and during anxiety stressors. All disorders evidenced diminished baseline HF-HRV relative to controls. Baseline HRV differences were maintained throughout relaxation. For hyperventilation, PD and GAD demonstrated greater HR than controls. Psychotropic medication did not account for HF-HRV differences except in OCD. Age and sex evidenced multiple main effects. Findings suggest that low baseline HF-HRV represents a common index for inhibitory deficits across PD, GAD, and SAD, which is consistent with the notion of autonomic inflexibility in anxiety disorders. Elevated HR responses to hyperventilation, however, are specific to PD and GAD. Copyright © 2012 Elsevier B.V. All rights reserved.
Evaluation of the metabolic rate based on the recording of the heart rate.
Malchaire, Jacques; d'AMBROSIO Alfano, Francesca Romana; Palella, Boris Igor
2017-06-08
The assessment of harsh working conditions requires a correct evaluation of the metabolic rate. This paper revises the basis described in the ISO 8996 standard for the evaluation of the metabolic rate at a work station from the recording of the heart rate of a worker during a representative period of time. From a review of the literature, formulas different from those given in the standard are proposed to estimate the maximum working capacity, the maximum heart rate, the heart rate and the metabolic rate at rest and the relation (HR vs. M) at the basis of the estimation of the equivalent metabolic rate, as a function of the age, height and weight of the person. A Monte Carlo simulation is used to determine, from the approximations of these parameters and formulas, the imprecision of the estimated equivalent metabolic rate. The results show that the standard deviation of this estimate varies from 10 to 15%.
Evaluation of the metabolic rate based on the recording of the heart rate
MALCHAIRE, Jacques; ALFANO, Francesca Romana d’AMBROSIO; PALELLA, Boris Igor
2017-01-01
The assessment of harsh working conditions requires a correct evaluation of the metabolic rate. This paper revises the basis described in the ISO 8996 standard for the evaluation of the metabolic rate at a work station from the recording of the heart rate of a worker during a representative period of time. From a review of the literature, formulas different from those given in the standard are proposed to estimate the maximum working capacity, the maximum heart rate, the heart rate and the metabolic rate at rest and the relation (HR vs. M) at the basis of the estimation of the equivalent metabolic rate, as a function of the age, height and weight of the person. A Monte Carlo simulation is used to determine, from the approximations of these parameters and formulas, the imprecision of the estimated equivalent metabolic rate. The results show that the standard deviation of this estimate varies from 10 to 15%. PMID:28250334
Nillni, Yael I.; Berenz, Erin C.; Rohan, Kelly J.; Zvolensky, Michael J.
2011-01-01
The current study examined sex differences in psychological (i.e., self-reported anxiety, panic symptoms, and avoidance) and physiological (i.e., heart rate and skin conductance level) response to, and recovery from, a laboratory biological challenge. Participants were a community-recruited sample of 128 adults (63.3% women; Mage = 23.2 years, SD = 8.9) who underwent a 4-minute 10% CO2-enriched air biological challenge. As predicted, women reported more severe physical panic symptoms and avoidance (i.e., less willingness to participate in another challenge) and demonstrated increased heart rate as compared to men above and beyond the variance accounted for by other theoretically-relevant variables (recent panic attack history, neuroticism, and anxiety sensitivity). Additionally, women demonstrated a faster rate of recovery with respect to heart rate compared to men. These results are in line with literature documenting sex-specific differences in panic psychopathology, and results are discussed in the context of possible mechanisms underlying sex differences in panic vulnerability. PMID:22115836
Heart Rate Recovery, Physical Activity Level, and Functional Status in Subjects With COPD.
Morita, Andrea A; Silva, Laís K O; Bisca, Gianna W; Oliveira, Joice M; Hernandes, Nidia A; Pitta, Fabio; Furlanetto, Karina C
2018-05-15
A normal heart rate reflects the balance between the sympathetic and parasympathetic autonomic nervous system. When the difference between heart rate at the end of an exercise test and after 1 min of recovery, known as the 1-min heart rate recovery, is ≤ 12 beats/min, this may indicate an abnormal delay. We sought to compare physical activity patterns and subjects' functional status with COPD with or without delayed 1-min heart rate recovery after the 6-min walk test (6MWT). 145 subjects with COPD (78 men, median [interquartile range (IQR)] age 65 [60-73] y, body mass index 25 [21-30] kg/m 2 , FEV 1 45 ± 15% predicted) were underwent the following assessments: spirometry, 6MWT, functional status, and physical activity in daily life (PADL). A delayed heart rate recovery of 1 min was defined as ≤ 12 beats/min. Subjects with delayed 1-min heart rate recovery walked a shorter distance in the 6MWT compared to subjects without delayed heart rate recovery (median [IQR] 435 [390-507] m vs 477 [425-515] m, P = .01; 81 [71-87] vs 87 [79-98]% predicted, P = .002). Regarding PADL, subjects with delayed heart rate recovery spent less time in the standing position (mean ± SD 185 ± 89 min vs 250 ± 107 min, P = .002) and more time in sedentary positions (472 ± 110 min vs 394 ± 129 min, P = .002). Scores based on the self-care domain of the London Chest Activity of Daily Living questionnaire and the activity domain of the Pulmonary Functional Status and Dyspnea questionnaire were also worse in the group with delayed heart rate recovery (6 ± 2 points vs 5 ± 2 points; P = .039 and 29 ± 24 points vs 19 ± 17 points; P = .037, respectively). Individuals with COPD who exhibit delayed 1-min heart rate recovery after the 6MWT exhibited worse exercise capacity as well as a more pronounced sedentary lifestyle and worse functional status than those without delayed heart rate recovery. Despite its assessment simplicity, heart rate recovery after the 6MWT can be further explored as a promising outcome in COPD. Copyright © 2018 by Daedalus Enterprises.
An, Sang Min; Park, Jong Suk; Kim, Sang Ho
2014-03-01
The purpose of this research was to investigate the effects of exercise capacity, heart rate recovery and heart rate variability after high-intensity exercise on caffeine concentration of energy drink. The volunteers for this study were 15 male university student. 15 subjects were taken basic physical examinations such as height, weight and BMI before the experiment. Primary tests were examined of VO2max per weight of each subjects by graded exercise test using Bruce protocol. Each of five subject was divided 3 groups (CON, ECGⅠ, ECGⅡ) by matched method based on weight and VO2max per weight what gained of primary test for minimize the differences of exercise capacity and ingestion of each groups. For the secondary tests, the groups of subjects were taken their materials before and after exercise as a blind test. After the ingestion, subjects were experimented on exercise test of VO2max 80% by treadmill until the all-out. Heart rate was measured by 1minute interval, and respiratory variables were analyzed VO2, VE, VT, RR and so on by automatic respiratory analyzer. And exercise exhaustion time was determined by stopwatch. Moreover, HRV was measured after exercise and recovery 3 min. Among the intake groups, ECGⅡ was showed the longest of exercise exhaustion time more than CON group (p = .05). Result of heart rate during exercise according to intake groups, there was significant differences of each time (p < .001), however, not significant differences of each groups and group verse time (p > .05). Result of RPE during exercise according to intake groups, there was significant differences of each time (p < .001), however, not significant differences of each groups and group verse time (p > .05). In conclusion, EDGⅡ showed the significant increase of exercise exhaustion time more than CON group (p=.05) and not significant differences in HR, RPE, RER, HRV, HRR, blood pressure (p > .05). Therefore, 2.5 mg/kg(-1) ingestion of energy drink might be positive effect to increase exercise performance capacity without side-effect in cardiovascular disease.
Laskey, Warren K.; Alomari, Ihab; Cox, Margueritte; Schulte, Phillip J.; Zhao, Xin; Hernandez, Adrian F.; Heidenreich, Paul A.; Eapen, Zubin J.; Yancy, Clyde; Bhatt, Deepak L.; Fonarow, Gregg C.
2015-01-01
Background Whether heart rate upon discharge following hospitalization for heart failure is associated with long‐term adverse outcomes and whether this association differs between patients with sinus rhythm (SR) and atrial fibrillation (AF) have not been well studied. Methods and Results We conducted a retrospective cohort study from clinical registry data linked to Medicare claims for 46 217 patients participating in Get With The Guidelines®–Heart Failure. Cox proportional‐hazards models were used to estimate the association between discharge heart rate and all‐cause mortality, all‐cause readmission, and the composite outcome of mortality/readmission through 1 year. For SR and AF patients with heart rate ≥75, the association between heart rate and mortality (expressed as hazard ratio [HR] per 10 beats‐per‐minute increment) was significant at 0 to 30 days (SR: HR 1.30, 95% CI 1.22 to 1.39; AF: HR 1.23, 95% CI 1.16 to 1.29) and 31 to 365 days (SR: HR 1.15, 95% CI 1.12 to 1.20; AF: HR 1.05, 95% CI 1.01 to 1.08). Similar associations between heart rate and all‐cause readmission and the composite outcome were obtained for SR and AF patients from 0 to 30 days but only in the composite outcome for SR patients over the longer term. The HR from 0 to 30 days exceeded that from 31 to 365 days for both SR and AF patients. At heart rates <75, an association was significant for mortality only for both SR and AF patients. Conclusions Among older patients hospitalized with heart failure, higher discharge heart rate was associated with increased risks of death and rehospitalization, with higher risk in the first 30 days and for SR compared with AF. PMID:25904590
Monazzam, Mohammad Reza; Shoja, Esmaeil; Zakerian, Seyed Abolfazl; Foroushani, Abbas Rahimi; Shoja, Mohsen; Gharaee, Masoumeh; Asgari, Amin
2018-07-01
This study aimed to investigate the effect of whole-body vibration and ambient lighting, as well as their combined effect on human discomfort, heart rate, and reaction time in laboratory conditions. 44 men were recruited with an average age of 25.4 ± 1.9 years. Each participant was subjected to 12 experimental steps, each step lasting five minutes for four different vibration accelerations in X, Y, and Z axes at a fixed frequency; three different lighting intensities of 50, 500, and 1000 lx were also considered. At each step, a visual computerized reaction test was taken from subjects and their heart rate recorded by pulse oximeter. In addition, the discomfort rate of subjects was measured using Borg scale. Increasing vibration acceleration significantly increased the discomfort rate and heart beat but not the reaction time. Lack of lighting caused more discomfort in the subjects, but there was no significant correlation between lighting intensity with heart rate and reaction time. The results also showed that the combined effect of vibration and lighting had no significant effect on any of the discomfort, heart rate, and reaction time variables. Whole-body vibration is an important factor in the development of human subjective and physiological reactions compared to lighting. Therefore, consideration of the level of vibration to which an individual is exposed in workplaces subject to vibration plays an important role in reducing the level of human discomfort, but its interaction with ambient lighting does not have a significant effect on human subjective and physiological responses.
Heart rate variability reactivity and new romance: Cause or consequence?
Bailey, Laura K; Davis, Ron
2017-09-01
There are documented physiological differences between single and coupled individuals during the "honeymoon period" of nascent romantic relationships. One such difference is in autonomic reactivity, specifically heart rate variability (HRV) reactivity. This finding had previously been interpreted as evidence of a stress buffering effect of relationship formation. The present study explored among university women two competing longitudinal hypotheses conceptualizing differences in HRV reactivity as either a cause or a consequence of romantic relationship formation. Results did not support the hypothesis that HRV reactivity changes as a consequence of beginning a new romantic relationship. Instead, lower HRV reactivity predicted greater relationship formation amongst women with low BMI and higher resting HRV. The functioning of the heart therefore predicted the likelihood that an individual would find love. These interactions may be the result of differing success rates of various mating strategies for women with low and high BMI and HRV. Copyright © 2017 Elsevier B.V. All rights reserved.
Influence of gestational age and time of day in baseline and heart rate variation of fetuses.
Li, Guangfei; Zhang, Song; Yang, Lin; Li, Shufang; Wang, Yan; Hao, Dongmei; Yang, Yimin; Li, Xuwen; Zhang, Lei; Xu, Mingzhou
2016-04-29
Fetal electrocardiography (FECG) places electrodes on the maternal abdomen to convert the fetal electrocardiosignals into fetal heart rate (FHR), improving the accuracy and comfort of pregnant woman. At the same time, FECG simplifies the procedure of long term monitoring in the perinatal period. Investigating the influence of gestational age and time of day on FHR features to distinguish between non-stress test (NST) normal fetuses and NST suspicious fetuses. A novel method of FHR baseline estimation was presented; then baseline value and fetal heart rate variation (FHRV) were analyzed in the time domain using FHR signals recorded from 52 fetuses. Baseline values in 1:00, 2:00, 4:00, 5:00 and heart rate variation (HRV) distribution showed a significant difference (p< 0.05) between NST normal fetuses and NST suspicious fetuses. The results suggest that NST normal and suspicious fetuses had same outcome and different FHR features. Accurately distinguishing normal fetuses and suspicious fetuses is important for lowering the false positive rate and reducing unnecessary clinical intervention.
Kellett, John; Li, Min; Rasool, Shahzeb; Green, Geoffrey C; Seely, Andrew
2011-11-01
Heart and breathing rates are predictors of disease severity and of a poor outcome. However, few reports have compared their machine measurements with traditional manual methods. A small rural Irish hospital. The heart and breathing rates of 377 acutely ill medical patients (mean age 68.3 SD 16.8 years) recorded by nursing staff at the time of admission to hospital was compared with those measured over 5 min by a piezoelectric belt and ECG monitor (the BT16 acquisition system). The mean breathing rate measured by the nursing staff (20.9 SD 4.8 breaths per min) and that measured by the BT16 piezoelectric belt (19.9 SD 4.5 breaths per min) were significantly different (p 0.004), as were the nurse and BT16 measured heart rates (85.4 SD 21.3 vs. 81.2 SD 18.7, p 0.004), and the correlation coefficient between the two methods of breathing and heart rate measurement were low. Nurse measured breathing rate measurements were clustered around rates of 18, 20 and 22 breaths per min. Unlike those obtained by nurses, BT16 measured heart and breathing rates were shown by logistic regression to be independent predictors of in-hospital mortality. There is a poor correlation between breathing and heart rates measured by traditional methods and those obtained by the BT16 device. BT16 derived breathing and heart rates, but not those measured manually, were independent predictors of in-hospital mortality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
[Respiratory infections, Down's syndrome and congenital heart disease: the CIVIC 21 study].
Medrano López, C; García-Guereta Silva, L; Lirio Casero, J; García Pérez, J
2009-07-01
We compare hospitalisation rates for acute respiratory tract infection in children younger than 24 months with significant congenital heart disease without Down's syndrome with those with Down's syndrome with or without congenital heart disease. This was an epidemiological, multicentre (53 Spanish hospitals), observational and prospective study, from October 2006 to April 2007. A total of 1085 patients were followed-up, of which 806 did not have Down's syndrome and 279 with Down's syndrome: 135 with significant, 38 with non significant and 105 without congenital heart disease. A total of 147 patients (13.1%; 95% CI, 11.2-15.2%) required hospitalisation due to respiratory infection. Rates in patients without and with Down's syndrome were 11% vs 19.1%. In the Down's group, 26.3% had no significant, a 23% had significant and 11.4% had no congenital heart disease. The main diagnosis was bronchiolitis (59.4%). An infectious agent was found in 36.2% cases. The specific admission rate due to respiratory syncytial virus was 4.4%, with differences in children without vs with Down's syndrome (3.2% vs 7.8%). In the Down's patients we found rates of 15.8%, 9.3% and 3% in the non-significant, significant and no congenital heart disease. Immunoprophylaxis against respiratory syncytial virus rates were 83.4% vs 39.9% in no Down's versus Down's syndrome patients. No differences were found in hospital stay or the severity. Hospital admission rates due to respiratory infection, and specifically respiratory syncytial virus, were higher in the Down's patients, particularly in the group with no significant congenital heart disease and low immunoprophylaxis against respiratory syncytial virus.
Antenatal fetal heart rate and "maternal intuition" as predictors of fetal sex.
Genuis, S; Genuis, S K; Chang, W C
1996-06-01
To determine if the antenatal fetal heart rate is a reliable predictor of fetal sex, if there is any correlation between "maternal intuition" and fetal gender, and if maternal intuition favors one sex over the other. Two hundred twelve consecutive maternity patients with singleton gestations underwent a total of 2,261 antepartum visits. Fetal heart rate assessment was carried out between 14 and 41 weeks of gestation. At 32 weeks, participants were asked if they had a strong intuitive feeling regarding the fetal gender. Following birth, data on the infant were recorded, and the information was analyzed. There was no significant difference in the baseline fetal heart rate between male and female fetuses at any recorded gestational age. One hundred ten patients (51.9%) in the sample indicated a strong belief about the sex of their fetuses, with the majority (63.6%) predicting a male. The accuracy of maternal intuition, however, was not significantly different from that of random guessing. In the current era of declining family size, an increased focus on absolute reproductive choice and proliferating reproductive technological services, prenatal sex determination and sex selection will continue to provoke increasing attention. Fetal heart rate determination and maternal intuition, however, are not valid predictors of fetal gender.
Metoprolol improves survival in severe traumatic brain injury independent of heart rate control.
Zangbar, Bardiya; Khalil, Mazhar; Rhee, Peter; Joseph, Bellal; Kulvatunyou, Narong; Tang, Andrew; Friese, Randall S; O'Keeffe, Terence
2016-02-01
Multiple prior studies have suggested an association between survival and beta-blocker administration in patients with severe traumatic brain injury (TBI). However, it is unknown whether this benefit of beta-blockers is dependent on heart rate control. The aim of this study was to assess whether rate control affects survival in patients receiving metoprolol with severe TBI. Our hypothesis was that improved survival from beta-blockade would be associated with a reduction in heart rate. We performed a 7-y retrospective analysis of all blunt TBI patients at a level-1 trauma center. Patients aged >16 y with head abbreviated injury scale 4 or 5, admitted to the intensive care unit (ICU) from the operating room or emergency room (ER), were included. Patients were stratified into two groups: metoprolol and no beta-blockers. Using propensity score matching, we matched the patients in two groups in a 1:1 ratio controlling for age, gender, race, admission vital signs, Glasgow coma scale, injury severity score, mean heart rate monitored during ICU admission, and standard deviation of heart rate during the ICU admission. Our primary outcome measure was mortality. A total of 914 patients met our inclusion criteria, of whom 189 received beta-blockers. A propensity-matched cohort of 356 patients (178: metoprolol and 178: no beta-blockers) was created. Patients receiving metoprolol had higher survival than those patients who did not receive beta-blockers (78% versus 68%; P = 0.04); however, there was no difference in the mean heart rate (89.9 ± 13.9 versus 89.9 ± 15; P = 0.99). Nor was there a difference in the mean of standard deviation of the heart rates (14.7 ± 6.3 versus 14.4 ± 6.5; P = 0.65) between the two groups. In Kaplan-Meier survival analysis, patients who received metoprolol had a survival advantage (P = 0.011) compared with patients who did not receive any beta-blockers. Our study shows an association with improved survival in patients with severe TBI receiving metoprolol, and this effect appears to be independent of any reduction in heart rate. We suggest that beta-blockers should be administered to all severe TBI patients irregardless of any perceived beta-blockade effect on heart rate. Published by Elsevier Inc.
Combinatorial effect of nicotine and black tea on heart rate variability: Useful or harmful?
Joukar, S; Sheibani, M
2017-06-01
The effect of nicotine on heart rate variability (HRV) is controversial. Autonomic nervous system is the main regulator of heart rhythm, and heart rate variability is an appropriate index to assessment of the effects of the autonomic system on heart. In this study, the combination effect of nicotine and black tea consumption on sympatho-vagal balance and heart rate variability was investigated in rats. Male Wistar rats were randomized into four groups as control, tea (2.5 g/100 cc, daily), nicotine (2 mg/kg/d) and tea plus nicotine groups which treated for 28 days, and in the 29th day, their electrocardiograms (lead II) were recorded. The mean of high-frequency power (HF) in tea, nicotine and tea plus nicotine groups was significantly more than control group (P < .05), and low-frequency power/high-frequency power (LF/HF) ratio in the nicotine and tea + nicotine groups was significantly less than control group (P < .05). LF values did not differ significantly among groups. Mean of standard deviation of normal RR intervals (SDNN) and square root of the mean squared differences of successive RR intervals (RMSSD) increased significantly in tea, nicotine and tea + nicotine groups in comparison with control group (P < .05) Overall, 4-week administration of black tea, nicotine or their combination with dosages used in this study can increase the heart rate variability and improve the sympatho-vagal balance in rat. © 2017 John Wiley & Sons Ltd.
Lemeshko, V V; Kaliman, P A; Belostotskaia, L I; Uchitel', A A
1982-04-01
The ATP-synthetase activity, the rate of oxygen uptake under different metabolic conditions, the tightness of coupling of respiration to oxidative phosphorylation and the cytochrome contents in heart mitochondria of rats from different age groups were studied under normal conditions and in hyperthyroidism. It was found that heart mitochondria of aged animals did not practically differ in terms of their functional activity from those of the young animals. Administration of thyroxin to the animals from all age groups produced no significant effects on the state of mitochondria, increasing the rate of ATP synthesis on alpha-glycerophosphate, which was especially well-pronounced in aged animals, and the cytochrome content in 1-month-old rats.
Perrichon, Prescilla; Grosell, Martin; Burggren, Warren W.
2017-01-01
Understanding cardiac function in developing larval fishes is crucial for assessing their physiological condition and overall health. Cardiac output measurements in transparent fish larvae and other vertebrates have long been made by analyzing videos of the beating heart, and modeling this structure using a conventional simple prolate spheroid shape model. However, the larval fish heart changes shape during early development and subsequent maturation, but no consideration has been made of the effect of different heart geometries on cardiac output estimation. The present study assessed the validity of three different heart models (the “standard” prolate spheroid model as well as a cylinder and cone tip + cylinder model) applied to digital images of complete cardiac cycles in larval mahi-mahi and red drum. The inherent error of each model was determined to allow for more precise calculation of stroke volume and cardiac output. The conventional prolate spheroid and cone tip + cylinder models yielded significantly different stroke volume values at 56 hpf in red drum and from 56 to 104 hpf in mahi. End-diastolic and stroke volumes modeled by just a simple cylinder shape were 30–50% higher compared to the conventional prolate spheroid. However, when these values of stroke volume multiplied by heart rate to calculate cardiac output, no significant differences between models emerged because of considerable variability in heart rate. Essentially, the conventional prolate spheroid shape model provides the simplest measurement with lowest variability of stroke volume and cardiac output. However, assessment of heart function—especially if stroke volume is the focus of the study—should consider larval heart shape, with different models being applied on a species-by-species and developmental stage-by-stage basis for best estimation of cardiac output. PMID:28725199
Knopf, Kerstin; Pössel, Patrick
2009-01-01
In contrast to previous stress research, studies concerning phobic disorders have never systematically investigated individual response differences between phobic participants integrating numerous different response measures. The aim of this article is to clarify the existence of significant individual response differences in psychophysiological responses (e.g., heart rate, skin conductance responses (SCR), corrugator, cortisol), subjective ratings (e.g., valence, arousal), and avoidance behavior in 46 spider phobic and 44 non-phobic women when exposed to 20 phobic and 20 neutral pictures. Previous studies that did not attend to individual response differences showed that, during phobic stimulation, phobic individuals have increased psychophysiological responses (heart rate, SCR, and corrugator responses), more negative valence rating, and more subjective arousal than non-phobic individuals. These results were confirmed by our data. With regard to individual response uniqueness, 1/3-2/3 of spider-phobic women with low responsiveness in heart rate, cortisol, and avoidance behavior were indistinguishable from non-phobic women during phobic stimulation. With SCR, corrugator EMG, and subjective ratings, no individual response uniqueness was found. Based on the findings, exposure therapy might be improved by tailoring interventions to individuals with a therapeutic focus on those psychophysiological measures that show the highest individual responsivity.
Cardiovascular reactivity patterns and pathways to hypertension: a multivariate cluster analysis.
Brindle, R C; Ginty, A T; Jones, A; Phillips, A C; Roseboom, T J; Carroll, D; Painter, R C; de Rooij, S R
2016-12-01
Substantial evidence links exaggerated mental stress induced blood pressure reactivity to future hypertension, but the results for heart rate reactivity are less clear. For this reason multivariate cluster analysis was carried out to examine the relationship between heart rate and blood pressure reactivity patterns and hypertension in a large prospective cohort (age range 55-60 years). Four clusters emerged with statistically different systolic and diastolic blood pressure and heart rate reactivity patterns. Cluster 1 was characterised by a relatively exaggerated blood pressure and heart rate response while the blood pressure and heart rate responses of cluster 2 were relatively modest and in line with the sample mean. Cluster 3 was characterised by blunted cardiovascular stress reactivity across all variables and cluster 4, by an exaggerated blood pressure response and modest heart rate response. Membership to cluster 4 conferred an increased risk of hypertension at 5-year follow-up (hazard ratio=2.98 (95% CI: 1.50-5.90), P<0.01) that survived adjustment for a host of potential confounding variables. These results suggest that the cardiac reactivity plays a potentially important role in the link between blood pressure reactivity and hypertension and support the use of multivariate approaches to stress psychophysiology.
Neshat, Hanieh; Jebreili, Mahnaz; Seyyedrasouli, Aleheh; Ghojazade, Morteza; Hosseini, Mohammad Bagher; Hamishehkar, Hamed
2016-06-01
Different studies have shown that the use of olfactory stimuli during painful medical procedures reduces infants' response to pain. The main purpose of the current study was to investigate the effect of breast milk odor and vanilla odor on premature infants' vital signs including heart rate and blood oxygen saturation during and after venipuncture. A total of 135 preterm infants were randomly selected and divided into three groups of control, vanilla odor, and breast milk odor. Infants in the breast milk group and the vanilla group were exposed to breast milk odor and vanilla odor from 5 minutes prior to sampling until 30 seconds after sampling. The results showed that breast milk odor has a significant effect on the changes of neonatal heart rate and blood oxygen saturation during and after venipuncture and decreased the variability of premature infants' heart rate and blood oxygen saturation. Vanilla odor has no significant effect on premature infants' heart rate and blood oxygen saturation. Breast milk odor can decrease the variability of premature infants' heart rate and blood oxygen saturation during and after venipuncture. Copyright © 2015. Published by Elsevier B.V.
Cognitive Performance and Heart Rate Variability: The Influence of Fitness Level
Luque-Casado, Antonio; Zabala, Mikel; Morales, Esther; Mateo-March, Manuel; Sanabria, Daniel
2013-01-01
In the present study, we investigated the relation between cognitive performance and heart rate variability as a function of fitness level. We measured the effect of three cognitive tasks (the psychomotor vigilance task, a temporal orienting task, and a duration discrimination task) on the heart rate variability of two groups of participants: a high-fit group and a low-fit group. Two major novel findings emerged from this study. First, the lowest values of heart rate variability were found during performance of the duration discrimination task, compared to the other two tasks. Second, the results showed a decrement in heart rate variability as a function of the time on task, although only in the low-fit group. Moreover, the high-fit group showed overall faster reaction times than the low-fit group in the psychomotor vigilance task, while there were not significant differences in performance between the two groups of participants in the other two cognitive tasks. In sum, our results highlighted the influence of cognitive processing on heart rate variability. Importantly, both behavioral and physiological results suggested that the main benefit obtained as a result of fitness level appeared to be associated with processes involving sustained attention. PMID:23437276
Gavurová, Beáta; Vagašová, Tatiana
2016-12-01
The aim of paper is to analyse the development of standardised mortality rates for ischemic heart diseases in relation to the income inequality in the regions of Slovakia. This paper assesses different types of income indicators, such as mean equivalised net income per household, Gini coefficient, unemployment rate, at risk of poverty threshold (60 % of national median), S80/S20 and their effect on mortality. Using data from the Slovak mortality database 1996-2013, the method of direct standardisation was applied to eliminate variances resulted from differences in age structures of the population across regions and over time. To examine the relationships between income indicators and standardised mortality rates, we used the tools of descriptive statistics and methods of correlation and regression analysis. At first, we show that Slovakia has the worst values of standardised mortality rates for ischemic heart diseases in EU countries. Secondly, mortality rates are significantly higher for males compared with females. Thirdly, mortality rates are improving from Eastern Slovakia to Western Slovakia; additionally, high differences in the results of variability are seen among Slovak regions. Finally, the unemployment rate, the poverty rate and equivalent disposable income were statistically significant income indicators. Main contribution of paper is to demonstrate regional differences between mortality and income inequality, and to point out the long-term unsatisfactory health outcomes.
Castellano, Julen; Casamichana, David; Dellal, Alexandre
2013-05-01
The aim of the study was to examine the extent to which changing the game format (possession play vs. regulation goals and goalkeepers vs. small goals only) and the number of players (3 vs. 3, 5 vs. 5 and 7 vs. 7) influenced the physiological and physical demands of small-sided games (SSGs) in soccer in semiprofessional players. Fourteen semiprofessional male soccer players were monitored with global positioning system and heart rate devices. Heart rate, player load, distance covered, running speed, and the number of accelerations were recorded for 9 different SSGs. The results show that changes both in game format and the number of players affect the players' physiological and physical demands. Possession play places greater physiological and physical demands on players, although reducing the number of players only increases the physiological load. In the 7 vs. 7 games, changing the game format did not alter the heart rate responses. Finally, in the possession play format, changing the number of players did not produce significant differences in heart rate responses, although physical demands did decrease in line with a reduction in the number of players. These results should help coaches to understand how modifying different aspects of SSGs has a differential effect on the players' physiological and physical demands. Moreover, coaches in semiprofessional and amateur teams have now consistent information to design and optimize their training time in mixing the technical, tactical, and physical aspects.
Motion-compensated detection of heart rate based on the time registration adaptive filter
NASA Astrophysics Data System (ADS)
Yang, Lei; Zhou, Jinsong; Jing, Juanjuan; Li, Yacan; Wei, Lidong; Feng, Lei; He, Xiaoying; Bu, Meixia; Fu, Xilu
2018-01-01
A non-contact heart rate detection method based on the dual-wavelength technique is proposed and demonstrated experimentally. The heart rate is obtained based on the PhotoPlethysmoGraphy (PPG). Each detection module uses the reflection detection probe which is composed of the LED and the photodiode. It is a well-known fact that the differences in the circuits of two detection modules result in different responses of two modules for motion artifacts. It will cause a time delay between the two signals. This poses a great challenge to compensate the motion artifacts during measurements. In order to solve this problem, we have firstly used the time registration and translated the signals to ensure that the two signals are consistent in time domain. Then the adaptive filter is used to compensate the motion artifacts. Moreover, the data obtained by using this non-contact detection system is compared with those of the conventional finger blood volume pulse (BVP) sensor by simultaneously measuring the heart rate of the subject. During the experiment, the left hand remains stationary and is detected by a conventional finger BVP sensor. Meanwhile, the moving palm of right hand is detected by the proposed system. The data obtained from the proposed non-contact system are consistent and comparable with that of the BVP sensor. This method can effectively suppress the interference caused by the two circuit differences and successfully compensate the motion artifacts. This technology can be used in medical and daily heart rate measurement.
Spaceflight-induced cardiovascular changes and recovery during NASA's Functional Task Test
NASA Astrophysics Data System (ADS)
Arzeno, Natalia M.; Stenger, Michael B.; Bloomberg, Jacob J.; Platts, Steven H.
2013-11-01
Microgravity-induced physiologic changes could impair a crewmember's performance upon return to a gravity environment. The Functional Task Test aims to correlate these physiologic alterations with changes in performance during mission-critical tasks. In this study, we evaluated spaceflight-induced cardiovascular changes during 11 functional tasks in 7 Shuttle astronauts before spaceflight, on landing day, and 1, 6, and 30 days after landing. Mean heart rate was examined during each task and autonomic activity was approximated by heart rate variability during the Recovery from Fall/Stand Test, a 2-min prone rest followed by a 3-min stand. Heart rate was increased on landing day during all of the tasks, and remained elevated 6 days after landing during 6 of the 11 tasks. Parasympathetic modulation was diminished and sympathovagal balance was increased on landing day. Additionally, during the stand test 6 days after landing, parasympathetic modulation remained suppressed and heart rate remained elevated compared to preflight levels. Heart rate and autonomic activity were not different from preflight levels 30 days after landing. We detected changes in heart rate and autonomic activity during a 3-min stand and a variety of functional tasks, where cardiovascular deconditioning was still evident 6 days after returning from short-duration spaceflight. The delayed recovery times for heart rate and parasympathetic modulation indicate the necessity of assessing functional performance after long-duration spaceflight to ensure crew health and safety.
NASA Astrophysics Data System (ADS)
Riedl, M.; Suhrbier, A.; Malberg, H.; Penzel, T.; Bretthauer, G.; Kurths, J.; Wessel, N.
2008-07-01
The parameters of heart rate variability and blood pressure variability have proved to be useful analytical tools in cardiovascular physics and medicine. Model-based analysis of these variabilities additionally leads to new prognostic information about mechanisms behind regulations in the cardiovascular system. In this paper, we analyze the complex interaction between heart rate, systolic blood pressure, and respiration by nonparametric fitted nonlinear additive autoregressive models with external inputs. Therefore, we consider measurements of healthy persons and patients suffering from obstructive sleep apnea syndrome (OSAS), with and without hypertension. It is shown that the proposed nonlinear models are capable of describing short-term fluctuations in heart rate as well as systolic blood pressure significantly better than similar linear ones, which confirms the assumption of nonlinear controlled heart rate and blood pressure. Furthermore, the comparison of the nonlinear and linear approaches reveals that the heart rate and blood pressure variability in healthy subjects is caused by a higher level of noise as well as nonlinearity than in patients suffering from OSAS. The residue analysis points at a further source of heart rate and blood pressure variability in healthy subjects, in addition to heart rate, systolic blood pressure, and respiration. Comparison of the nonlinear models within and among the different groups of subjects suggests the ability to discriminate the cohorts that could lead to a stratification of hypertension risk in OSAS patients.
ERIC Educational Resources Information Center
Dickey, Patsy A.
1980-01-01
Forty female students were used to compare the incremental difference in heart rate of shorthand writers when they were informed and not informed of shorthand speeds prior to dictation. It was concluded that students' performances were enhanced by receiving instructions as to speed of dictation prior to the take. (Author/CT)
Modeling heart rate variability including the effect of sleep stages
NASA Astrophysics Data System (ADS)
Soliński, Mateusz; Gierałtowski, Jan; Żebrowski, Jan
2016-02-01
We propose a model for heart rate variability (HRV) of a healthy individual during sleep with the assumption that the heart rate variability is predominantly a random process. Autonomic nervous system activity has different properties during different sleep stages, and this affects many physiological systems including the cardiovascular system. Different properties of HRV can be observed during each particular sleep stage. We believe that taking into account the sleep architecture is crucial for modeling the human nighttime HRV. The stochastic model of HRV introduced by Kantelhardt et al. was used as the initial starting point. We studied the statistical properties of sleep in healthy adults, analyzing 30 polysomnographic recordings, which provided realistic information about sleep architecture. Next, we generated synthetic hypnograms and included them in the modeling of nighttime RR interval series. The results of standard HRV linear analysis and of nonlinear analysis (Shannon entropy, Poincaré plots, and multiscale multifractal analysis) show that—in comparison with real data—the HRV signals obtained from our model have very similar properties, in particular including the multifractal characteristics at different time scales. The model described in this paper is discussed in the context of normal sleep. However, its construction is such that it should allow to model heart rate variability in sleep disorders. This possibility is briefly discussed.
Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years - United States, 1968-2015.
Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele
2018-03-30
Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. 1968-2015. The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968-2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968-2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases occurring during the 1970s and 1980s followed by small but steady increases until approximately 2005. Since 2005, modest decreases have occurred in the black-white ratio of heart disease death rates at the national level. The majority of states had increases in black-white mortality ratios from 1968 to 2015. The number of states with black-white mortality ratios >1 increased from 16 (40%) to 27 (67.5%). Although heart disease death rates decreased both for blacks and whites from 1968 to 2015, substantial differences in decreases were found by race and state. At the national level and in most states, blacks experienced smaller decreases in heart disease death rates than whites for the majority of the period. Overall, the black-white disparity in heart disease death rates increased from 1968 to 2005, with a modest decrease from 2005 to 2015. Since 1968, substantial increases have occurred in black-white disparities of heart disease death rates in the United States at the national level and in many states. These increases appear to be due to faster decreases in heart disease death rates for whites than blacks, particularly from the late 1970s until the mid-2000s. Despite modest decreases in black-white disparities at the national level since 2005, in 2015, heart disease death rates were 21% higher among blacks than among whites. This study demonstrates the use of NVSS data to conduct surveillance of heart disease death rates by race and of black-white disparities in heart disease death rates. Continued surveillance of temporal trends in heart disease death rates by race can provide valuable information to policy makers and public health practitioners working to reduce heart disease death rates both for blacks and whites and disparities between blacks and whites.
Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years — United States, 1968–2015
Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele
2018-01-01
Problem/Condition Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. Period Covered 1968–2015. Description of System The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968–2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968–2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. Results From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases occurring during the 1970s and 1980s followed by small but steady increases until approximately 2005. Since 2005, modest decreases have occurred in the black-white ratio of heart disease death rates at the national level. The majority of states had increases in black-white mortality ratios from 1968 to 2015. The number of states with black-white mortality ratios >1 increased from 16 (40%) to 27 (67.5%). Interpretation Although heart disease death rates decreased both for blacks and whites from 1968 to 2015, substantial differences in decreases were found by race and state. At the national level and in most states, blacks experienced smaller decreases in heart disease death rates than whites for the majority of the period. Overall, the black-white disparity in heart disease death rates increased from 1968 to 2005, with a modest decrease from 2005 to 2015. Public Health Action Since 1968, substantial increases have occurred in black-white disparities of heart disease death rates in the United States at the national level and in many states. These increases appear to be due to faster decreases in heart disease death rates for whites than blacks, particularly from the late 1970s until the mid-2000s. Despite modest decreases in black-white disparities at the national level since 2005, in 2015, heart disease death rates were 21% higher among blacks than among whites. This study demonstrates the use of NVSS data to conduct surveillance of heart disease death rates by race and of black-white disparities in heart disease death rates. Continued surveillance of temporal trends in heart disease death rates by race can provide valuable information to policy makers and public health practitioners working to reduce heart disease death rates both for blacks and whites and disparities between blacks and whites. PMID:29596406
Hanprasertpong, T; Petpichetchian, C; Ponglopisit, S; Suksai, M; Kor-Anantakul, O; Geater, A; Pruksanusak, N; Hanprasertpong, J
2016-05-01
A prospective study was conducted for comparing the incidence of fetal bradycardia and level of fetal heart rate change following a second-trimester genetic amniocentesis with and without placental injury. A total of 257 and 495 participants in injured and non-injured groups were analysed. The incidence of fetal bradycardia following amniocentesis was not statistically different between the two groups (1.17%, [95% CI 0.24, 3.37] and 0.20%, [95% CI 0.005, 1.12]) in injured and non-injured placenta groups, respectively; p = 0.118). The mean change in baseline fetal heart rate before and after amniocentesis was also not significantly different between the two groups (p = 0.844). No fetal death or pregnancy loss occurred within 4 weeks after the procedure. All 4 bradycardia participants were normal and healthy and had an appropriate weight for their gestational age. We conclude that placental injury during a second-trimester genetic amniocentesis due to advanced maternal age poses only a low risk of fetal bradycardia, and there is no evidence of differences between subjects with injured and non-injured placenta in the changes in fetal heart rate.
Jamner, L D; Shapiro, D; Goldstein, I B; Hug, R
1991-01-01
Ambulatory blood pressure and heart rate responses were obtained in 33 male paramedics during a 24-hour work shift to examine the effects of episodes of occupational stress on cardiovascular reactivity and subjective reports of stress. The aim of this study was to determine how individual differences in cynical hostility and defensiveness interacted with situational demands to affect cardiovascular responses in a natural setting. Defensiveness was found to interact significantly with cynical hostility in predicting subjects' heart rate responses in different work contexts. Specifically, in a hospital setting involving interpersonal conflict, subjects who were high in both defensiveness and hostility showed heart rate responses approximately 10 bpm higher than subjects who were high in hostility but low in defensiveness. The same pattern of relationships was obtained for diastolic blood pressure. High and low hostile subjects were also found to differ from each other in their daily mean levels of ambulatory blood pressure during awake and sleep periods. These findings obtained in a natural setting lend further support to the significance of cynical hostility for cardiovascular reactivity. The results for defensiveness suggest the need for further research on the role of conflicting attitudes in the pathophysiology of cardiovascular diseases.
Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle
NASA Technical Reports Server (NTRS)
Moore, A. D. Jr; Lee, S. M.; Greenisen, M. C.; Bishop, P.
1997-01-01
Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.
Heart rate variability based on risk stratification for type 2 diabetes mellitus.
Silva-E-Oliveira, Julia; Amélio, Pâmela Marina; Abranches, Isabela Lopes Laguardia; Damasceno, Dênis Derly; Furtado, Fabianne
2017-01-01
To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability. Avaliar a variabilidade da frequência cardíaca em adultos com diferentes níveis de risco para diabetes mellitus tipo 2. O grau de risco para diabetes mellitus tipo 2 de 130 participantes (41 homens) foi avaliado pelo questionário Finnish Diabetes Risk Score. Os participantes foram classificados em baixo risco (n=26), risco levemente elevado (n=41), risco moderado (n=27) e alto risco (n=32). Para medir a variabilidade da frequência cardíaca, utilizou-se o frequencímetro Polar S810i® para obter séries de intervalo RR para cada indivíduo, em repouso, durante 5 minutos; posteriormente, realizou-se análise por meio de índices lineares e não-lineares. O grupo com maior risco para diabetes mellitus tipo 2 teve uma diminuição significante nos índices lineares e não-lineares da variabilidade da frequência cardíaca. Os resultados apontam que indivíduos com risco alto para diabetes mellitus tipo 2 tem menor variabilidade da frequência cardíaca. To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability.
Cardiovascular responses to postural changes: differences with age for women and men
NASA Technical Reports Server (NTRS)
Frey, M. A.; Tomaselli, C. M.; Hoffler, W. G.
1994-01-01
The cardiovascular responses to postural change, and how they are affected by aging, are inadequately described in women. Therefore, the authors examined the influence of age and sex on the responses of blood pressure, cardiac output, heart rate, and other variables to change in posture. Measurements were made after 10 minutes each in the supine, seated, and standing positions in 22 men and 25 women who ranged in age from 21 to 59 years. Several variables differed, both by sex and by age, when subjects were supine. On rising, subjects' diastolic and mean arterial pressures, heart rate, total peripheral resistance (TPR), and thoracic impedance increased; cardiac output, stroke volume, and mean stroke ejection rate decreased; and changes in all variables, except heart rate, were greater from supine to sitting than sitting to standing. The increase in heart rate was greater in the younger subjects, and increases in TPR and thoracic impedance were greater in the older subjects. Stroke volume decreased less, and TPR and thoracic impedance increased more, in the women than in the men. The increase in TPR was particularly pronounced in the older women. These studies show that the cardiovascular responses to standing differ, in some respects, between the sexes and with age. The authors suggest that the sex differences are, in part, related to greater decrease of thoracic blood volume with standing in women than in men, and that the age differences result, in part, from decreased responsiveness of the high-pressure baroreceptor system.
Dae-Geun Jang; Byung-Hoon Ko; Sub Sunoo; Sang-Seok Nam; Hun-Young Park; Sang-Kon Bae
2016-08-01
This preliminary study investigates feasibility of a running speed based heart rate (HR) prediction. It is basically motivated from the assumption that there is a significant relationship between HR and the running speed. In order to verify the assumption, HR and running speed data from 217 subjects of varying aerobic capabilities were simultaneously collected during an incremental treadmill exercise. A running speed was defined as a treadmill speed and its corresponding heart rate was calculated by averaging the last one minute HR values of each session. The feasibility was investigated by assessing a correlation between the heart rate and the running speed using inter-subject (between-subject) and intra-subject (within-subject) datasets with regression orders of 1, 2, 3, and 4, respectively. Furthermore, HR differences between actual and predicted HRs were also employed to investigate the feasibility of the running speed in predicting heart rate. In the inter-subject analysis, a strong positive correlation and a reasonable HR difference (r = 0.866, 16.55±11.24 bpm @ 1st order; r = 0.871, 15.93±11.49 bpm @ 2nd order; r = 0.897, 13.98±10.80 bpm @ 3rd order; and r = 0.899, 13.93±10.64 bpm @ 4th order) were obtained, and a very high positive correlation and a very low HR difference (r = 0.978, 6.46±3.89 bpm @ 1st order; r = 0.987, 5.14±2.87 bpm @ 2nd order; r = 0.996, 2.61±2.03 bpm @ 3rd order; and r = 0.997, 2.04±1.73 bpm @ 4th order) were obtained in the intra-subject analysis. It can therefore be concluded that 1) heart rate is highly correlated with a running speed; 2) heart rate can be approximately estimated by a running speed with a proper statistical model (e.g., 3rd-order regression); and 3) an individual HR-speed calibration process may improve the prediction accuracy.
Evaluation of a strapless heart rate monitor during simulated flight tasks.
Wang, Zhen; Fu, Shan
2016-01-01
Pilots are under high task demands during flight. Monitoring pilot's physiological status is very important in the evaluation of pilot's workload and flight safety. Recently, physiological status monitor (PSM) has been embedded into a watch that can be used without a conventional chest strap. This makes it possible to unobtrusively monitor, log and transmit pilot's physiological measurements such as heart rate (HR) during flight tasks. The purpose of this study is to validate HR recorded by a strapless heart rate watch against criterion ECG-derived HR. Ten commercial pilots (mean ± SD : age: 39.1 ± 7.8 years; total flight hours 7173.2 ± 5270.9 hr) performed three routinely trained flight tasks in a full flight simulator: wind shear go-around (WG), takeoff and climb (TC), and hydraulic failure (HF). For all tasks combined (overall) and for each task, differences between the heart rate watch measurements and the criterion data were small (mean difference [95% CI]: overall: -0.71 beats/min [-0.85, -0.57]; WG: -0.90 beats/min [-1.15, -0.65]; TC: -0.69 beats/min [-0.98, -0.40]; HF: -0.61 beats/min [-0.80, -0.42]). There were high correlations between the heart rate watch measurements and the ECG-derived HR for all tasks (r ≥ 0.97, SEE < 3). Bland-Altman plots also show high agreements between the watch measurements and the criterion HR. These results suggest that the strapless heart rate watch provides valid measurements of HR during simulated flight tasks and could be a useful tool for pilot workload evaluation.
A comparison of the cardiovascular effects of simulated and spontaneous laughter.
Law, Mikaela M; Broadbent, Elizabeth A; Sollers, John J
2018-04-01
Laughter has long been regarded as beneficial for health, but the mechanisms are not clearly understood. The current study aimed to compare the acute cardiovascular effects of spontaneous and simulated laughter. A mixed factorial experiment was performed to examine changes in cardiovascular variables in response to experimental tasks across conditions. A sample of 72 participants were randomised to one of three 6 min interventions. Participants in the simulated laughter condition were asked to generate fake laughter, the spontaneous laughter condition viewed a humorous video, and the control condition watched a non-humorous documentary. This was followed by a laboratory stress task. Heart rate and heart rate variability (as indexed by rMSSD) were monitored continuously throughout the experiment using ECG. The simulated laughter condition had a significantly higher heart rate (p < .001, η p 2 = .26) and lower rMSSD (p < .001, η p 2 = .13) during the laughter task compared to the other two conditions. Follow-up hierarchical regressions indicated that the difference in heart rate was due to the fact that the simulated condition produced more laughter. The difference in rMSSD, however, was unique to the simulated condition even when controlling for the amount of laughter. The simulated laughter condition had a significantly lower mean HR during the stress task but this was not significant after controlling amount of laughter produced. Laughter leads to increased heart rate and reduced heart rate variability, which is similar to the effects of exercise. This finding is more pronounced in simulated laughter. Copyright © 2018 Elsevier Ltd. All rights reserved.
Kommers, Deedee R; Joshi, Rohan; van Pul, Carola; Atallah, Louis; Feijs, Loe; Oei, Guid; Bambang Oetomo, Sidarto; Andriessen, Peter
2017-03-01
To determine whether heart rate variability (HRV) can serve as a surrogate measure to track regulatory changes during kangaroo care, a period of parental coregulation distinct from regulation within the incubator. Nurses annotated the starting and ending times of kangaroo care for 3 months. The pre-kangaroo care, during-kangaroo care, and post-kangaroo care data were retrieved in infants with at least 10 accurately annotated kangaroo care sessions. Eight HRV features (5 in the time domain and 3 in the frequency domain) were used to visually and statistically compare the pre-kangaroo care and during-kangaroo care periods. Two of these features, capturing the percentage of heart rate decelerations and the extent of heart rate decelerations, were newly developed for preterm infants. A total of 191 kangaroo care sessions were investigated in 11 preterm infants. Despite clinically irrelevant changes in vital signs, 6 of the 8 HRV features (SD of normal-to-normal intervals, root mean square of the SD, percentage of consecutive normal-to-normal intervals that differ by >50 ms, SD of heart rate decelerations, high-frequency power, and low-frequency/high-frequency ratio) showed a visible and statistically significant difference (P <.01) between stable periods of kangaroo care and pre-kangaroo care. HRV was reduced during kangaroo care owing to a decrease in the extent of transient heart rate decelerations. HRV-based features may be clinically useful for capturing the dynamic changes in autonomic regulation in response to kangaroo care and other changes in environment and state. Copyright © 2016 Elsevier Inc. All rights reserved.
Hörnchen, H; Betz, R; Kotlarek, F; Roebruck, P
1983-01-01
In 1965 URBACH et al. and RUDOLPH et al. [35, 39] described a loss of heart rate variability in severely ill neonates. In this study we investigated the correlation between instantaneous heart rate patterns and status diagnosis. We used a microprocessor-based cardiorespirography system. Seventy five newborn infants (51 prematures and 24 term neonates) were studied for about 12 hours each. Twenty nine patients had a second record after the first investigation. Parameters were: Type of frequency and oscillation, long time variability (LTV), short time variability (STV) and the newly introduced P-value (maximal difference between two successive R-peaks in five minutes). We found clear differences between the study groups. With increasing severity of illness mean values ("group mean values") of long time variability, short time variability and P-value decreased. Fixed heart rate became predominant. The most pronounced loss of heart rate variability was seen in infants with severe intracranial bleeding, thus offering a tentative diagnosis. For statistical analysis long time variability and the silent oscillation type have been proved as best parameters for this diagnosis. Severely decreased heart rate variations also have been seen in infants with acute renal failure--possibly because of brain edema--, after application of muscle relaxants, repeated doses of sedatives, and after prolonged anesthesia. Otherwise, the heart rate variability was probably dependent on age and gestational age in prematures and newborn infants without intracranial bleeding. It is possible to use microprocessor-based long time cardiorespirography as a simple screening method for the diagnosis of neonatal intracerebral bleeding. In future experiences transcutaneous measurements of oxygen tension should be included.
2014-01-01
Background Extracting cardiorespiratory signals from non-invasive and non-contacting sensor arrangements, i.e. magnetic induction sensors, is a challenging task. The respiratory and cardiac signals are mixed on top of a large and time-varying offset and are likely to be disturbed by measurement noise. Basic filtering techniques fail to extract relevant information for monitoring purposes. Methods We present a real-time filtering system based on an adaptive Kalman filter approach that separates signal offsets, respiratory and heart signals from three different sensor channels. It continuously estimates respiration and heart rates, which are fed back into the system model to enhance performance. Sensor and system noise covariance matrices are automatically adapted to the aimed application, thus improving the signal separation capabilities. We apply the filtering to two different subjects with different heart rates and sensor properties and compare the results to the non-adaptive version of the same Kalman filter. Also, the performance, depending on the initialization of the filters, is analyzed using three different configurations ranging from best to worst case. Results Extracted data are compared with reference heart rates derived from a standard pulse-photoplethysmographic sensor and respiration rates from a flowmeter. In the worst case for one of the subjects the adaptive filter obtains mean errors (standard deviations) of -0.2 min −1 (0.3 min −1) and -0.7 bpm (1.7 bpm) (compared to -0.2 min −1 (0.4 min −1) and 42.0 bpm (6.1 bpm) for the non-adaptive filter) for respiration and heart rate, respectively. In bad conditions the heart rate is only correctly measurable when the Kalman matrices are adapted to the target sensor signals. Also, the reduced mean error between the extracted offset and the raw sensor signal shows that adapting the Kalman filter continuously improves the ability to separate the desired signals from the raw sensor data. The average total computational time needed for the Kalman filters is under 25% of the total signal length rendering it possible to perform the filtering in real-time. Conclusions It is possible to measure in real-time heart and breathing rates using an adaptive Kalman filter approach. Adapting the Kalman filter matrices improves the estimation results and makes the filter universally deployable when measuring cardiorespiratory signals. PMID:24886253
Foussier, Jerome; Teichmann, Daniel; Jia, Jing; Misgeld, Berno; Leonhardt, Steffen
2014-05-09
Extracting cardiorespiratory signals from non-invasive and non-contacting sensor arrangements, i.e. magnetic induction sensors, is a challenging task. The respiratory and cardiac signals are mixed on top of a large and time-varying offset and are likely to be disturbed by measurement noise. Basic filtering techniques fail to extract relevant information for monitoring purposes. We present a real-time filtering system based on an adaptive Kalman filter approach that separates signal offsets, respiratory and heart signals from three different sensor channels. It continuously estimates respiration and heart rates, which are fed back into the system model to enhance performance. Sensor and system noise covariance matrices are automatically adapted to the aimed application, thus improving the signal separation capabilities. We apply the filtering to two different subjects with different heart rates and sensor properties and compare the results to the non-adaptive version of the same Kalman filter. Also, the performance, depending on the initialization of the filters, is analyzed using three different configurations ranging from best to worst case. Extracted data are compared with reference heart rates derived from a standard pulse-photoplethysmographic sensor and respiration rates from a flowmeter. In the worst case for one of the subjects the adaptive filter obtains mean errors (standard deviations) of -0.2 min(-1) (0.3 min(-1)) and -0.7 bpm (1.7 bpm) (compared to -0.2 min(-1) (0.4 min(-1)) and 42.0 bpm (6.1 bpm) for the non-adaptive filter) for respiration and heart rate, respectively. In bad conditions the heart rate is only correctly measurable when the Kalman matrices are adapted to the target sensor signals. Also, the reduced mean error between the extracted offset and the raw sensor signal shows that adapting the Kalman filter continuously improves the ability to separate the desired signals from the raw sensor data. The average total computational time needed for the Kalman filters is under 25% of the total signal length rendering it possible to perform the filtering in real-time. It is possible to measure in real-time heart and breathing rates using an adaptive Kalman filter approach. Adapting the Kalman filter matrices improves the estimation results and makes the filter universally deployable when measuring cardiorespiratory signals.
van der Werf, N R; Willemink, M J; Willems, T P; Greuter, M J W; Leiner, T
2017-12-28
The objective of this study was to evaluate the influence of iterative reconstruction on coronary calcium scores (CCS) at different heart rates for four state-of-the-art CT systems. Within an anthropomorphic chest phantom, artificial coronary arteries were translated in a water-filled compartment. The arteries contained three different calcifications with low (38 mg), medium (80 mg) and high (157 mg) mass. Linear velocities were applied, corresponding to heart rates of 0, < 60, 60-75 and > 75 bpm. Data were acquired on four state-of-the-art CT systems (CT1-CT4) with routinely used CCS protocols. Filtered back projection (FBP) and three increasing levels of iterative reconstruction (L1-L3) were used for reconstruction. CCS were quantified as Agatston score and mass score. An iterative reconstruction susceptibility (IRS) index was used to assess susceptibility of Agatston score (IRS AS ) and mass score (IRS MS ) to iterative reconstruction. IRS values were compared between CT systems and between calcification masses. For each heart rate, differences in CCS of iterative reconstructed images were evaluated with CCS of FBP images as reference, and indicated as small (< 5%), medium (5-10%) or large (> 10%). Statistical analysis was performed with repeated measures ANOVA tests. While subtle differences were found for Agatston scores of low mass calcification, medium and high mass calcifications showed increased CCS up to 77% with increasing heart rates. IRS AS of CT1-T4 were 17, 41, 130 and 22% higher than IRS MS . Not only were IRS significantly different between all CT systems, but also between calcification masses. Up to a fourfold increase in IRS was found for the low mass calcification in comparison with the high mass calcification. With increasing iterative reconstruction strength, maximum decreases of 21 and 13% for Agatston and mass score were found. In total, 21 large differences between Agatston scores from FBP and iterative reconstruction were found, while only five large differences were found between FBP and iterative reconstruction mass scores. Iterative reconstruction results in reduced CCS. The effect of iterative reconstruction on CCS is more prominent with low-density calcifications, high heart rates and increasing iterative reconstruction strength.
Addison, Paul S; Jacquel, Dominique; Foo, David M H; Borg, Ulf R
2017-11-09
The robust monitoring of heart rate from the video-photoplethysmogram (video-PPG) during challenging conditions requires new analysis techniques. The work reported here extends current research in this area by applying a motion tolerant algorithm to extract high quality video-PPGs from a cohort of subjects undergoing marked heart rate changes during a hypoxic challenge, and exhibiting a full range of skin pigmentation types. High uptimes in reported video-based heart rate (HR vid ) were targeted, while retaining high accuracy in the results. Ten healthy volunteers were studied during a double desaturation hypoxic challenge. Video-PPGs were generated from the acquired video image stream and processed to generate heart rate. HR vid was compared to the pulse rate posted by a reference pulse oximeter device (HR p ). Agreement between video-based heart rate and that provided by the pulse oximeter was as follows: Bias = - 0.21 bpm, RMSD = 2.15 bpm, least squares fit gradient = 1.00 (Pearson R = 0.99, p < 0.0001), with a 98.78% reporting uptime. The difference between the HR vid and HR p exceeded 5 and 10 bpm, for 3.59 and 0.35% of the reporting time respectively, and at no point did these differences exceed 25 bpm. Excellent agreement was found between the HR vid and HR p in a study covering the whole range of skin pigmentation types (Fitzpatrick scales I-VI), using standard room lighting and with moderate subject motion. Although promising, further work should include a larger cohort with multiple subjects per Fitzpatrick class combined with a more rigorous motion and lighting protocol.
Takahashi, Anielle C M; Porta, Alberto; Melo, Ruth C; Quitério, Robison J; da Silva, Ester; Borghi-Silva, Audrey; Tobaldini, Eleonora; Montano, Nicola; Catai, Aparecida M
2012-06-01
Increasing age is associated with a reduction in overall heart rate variability as well as changes in complexity of physiologic dynamics. The aim of this study was to verify if the alterations in autonomic modulation of heart rate caused by the aging process could be detected by Shannon entropy (SE), conditional entropy (CE) and symbolic analysis (SA). Complexity analysis was carried out in 44 healthy subjects divided into two groups: old (n = 23, 63 ± 3 years) and young group (n = 21, 23 ± 2). It was analyzed SE, CE [complexity index (CI) and normalized CI (NCI)] and SA (0V, 1V, 2LV and 2ULV patterns) during short heart period series (200 cardiac beats) derived from ECG recordings during 15 min of rest in a supine position. The sequences characterized by three heart periods with no significant variations (0V), and that with two significant unlike variations (2ULV) reflect changes in sympathetic and vagal modulation, respectively. The unpaired t test (or Mann-Whitney rank sum test when appropriate) was used in the statistical analysis. In the aging process, the distributions of patterns (SE) remain similar to young subjects. However, the regularity is significantly different; the patterns are more repetitive in the old group (a decrease of CI and NCI). The amounts of pattern types are different: 0V is increased and 2LV and 2ULV are reduced in the old group. These differences indicate marked change of autonomic regulation. The CE and SA are feasible techniques to detect alteration in autonomic control of heart rate in the old group.
Effects and after-effects of chewing gum on vigilance, heart rate, EEG and mood.
Allen, Andrew P; Jacob, Tim J C; Smith, Andrew P
2014-06-22
Research has shown that chewing gum improves attention, although the mechanism for this effect remains unclear. This study investigated the effects and after-effects of chewing gum on vigilance, mood, heart rate and EEG. Participants completed a vigilance task four times; at baseline, with or without chewing gum, and twice post-chewing. EEG alpha and beta power at left frontal and temporal lobes, subjective mood and heart rate were assessed. Chewing gum shortened reaction time and increased the rate of hits, although hits fell during the second post-chewing task. Chewing gum heightened heart rate, but only during chewing. Gum also increased beta power at F7 and T3 immediately post-chewing, but not following the post-chewing tasks. The findings show that chewing gum affects several different indicators of alertness. Copyright © 2014 Elsevier Inc. All rights reserved.
Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K
2018-03-01
Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P < 0.001. There were no such differences for turbulence slope (Ts). In the 24-hour analysis almost all heart rate variability parameters were significantly lower in the systemic lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R = 0.464; P < 0.05, a negative correlation between low/high frequency ratio and r-MSSD, R = -0.454; P < 0.05; p50NN, R = -0.435; P < 0.05 and high frequency, R = -0.478; P < 0.05. In contrast, there was no statistically significant correlation between heart rate turbulence and other variables evaluated, including disease duration and the type of autoantibodies. Our study confirms the presence of autonomic disorders with respect to both heart rate variability and heart rate turbulence parameters and the presence of diurnal disturbances of sympathetic-parasympathetic balance. Further studies are required.
Role of paediatric assist device in bridge to transplant
Hetzer, Roland; Javier, Mariano Francisco del Maria
2018-01-01
Background While heart transplantation has gained recognition as the gold standard therapy for advanced heart failure, the scarcity of donor organs has become an important concern. The evolution of surgical alternatives such as ventricular assist devices (VADs), allow for recovery of the myocardium and ensure patient survival until heart transplantation becomes possible. This report elaborates the role of VADs as a bridge to heart transplantation in infants and children (≤18 years old) with end-stage heart failure. Methods A retrospective review of the medical records of 201 heart transplant recipients between May 1986 and September 2014 identified 78 children [38.8%; mean age 7.2 (7.8±6.0) years old; IQR: 2.6–11.8 years] with advanced heart failure who were supported with a VAD [left VAD (LVAD) =21; biventricular VAD (BVAD) =57] as a bridge to heart transplantation. Fourteen (17.9%) patients were less than 1 year old; 15 (19.2%) children had a cardiac arrest and underwent cardiopulmonary resuscitation, with 7 of these patients also requiring extracorporeal membrane oxygenation (ECMO) support prior to implantation of a VAD. The aetiology of heart failure was primarily cardiomyopathy (dilative, restrictive from endocardial fibrosis, idiopathic or toxic-induced), reported in 56 (71.8%) patients. The VADs employed were primarily Berlin Heart EXCOR® (n=63), HeartWare (n=13), Berlin Heart INCOR® (n=1), and Toyobo (n=1). Results Mean duration of VAD support was 59 (133.37±191.57) days (range, 1–945 days; IQR: 23–133 days) before a donor heart became available. The primary complication encountered while patients were being bridged to transplant was mediastinal bleeding (7.8%). The main indication for pump exchanges was thrombus formation in the valves. There was no incidence of technical failure of the blood pump or driving system components. Skin infections around the cannulae occurred in 2.5%. Adverse neurological symptoms (thromboembolism 11.1%, cerebral haemorrhage 3.6%) that occurred did not have any permanent neurological sequelae that could be detected on clinical examination in this study. Mean duration of follow-up was 9.4 (10.3±7.6) years (IQR: 3.74–15.14 years). Cumulative survival rates of patients bridged to transplantation with VAD were 93.6%±2.8%, 84.6%±4.1%, 79.1%±4.7%, 63.8%±6.2%, 61.6%±7.1%, and 52.1%±9.3% at 30 days, 1, 5, 10, 15 and 20 years, respectively. There was no statistically significant difference (P=0.79) in survival rates of patients bridged to heart transplantation with VAD compared to those who underwent primary heart transplantation. Post-transplant survival rates stratified according to the type of VAD implanted and number of ventricles supported were not statistically different (P=0.93 and 0.73, respectively). In addition, post-transplant survival rates were not significantly different when age, gender and diagnosis were adjusted for. Furthermore, no statistically significant difference was found when post-transplant survival rates of children who had episodes of rejection were compared to those who did not have episodes of rejection. Conclusions The results in this series demonstrate that VADs satisfactorily support paediatric patients with advanced heart failure from a variety of aetiologies until heart transplantation. The data further suggests that patients bridged with VADs have comparable long-term post-transplant survival as those undergoing primary heart transplantation. PMID:29492386
Fatty acid utilization in pressure-overload hypertrophied rat hearts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reibel, D.K.; O'Rourke, B.
1986-03-05
The authors have previously shown that the levels of total tissue coenzyme A and carnitine are reduced in hypertrophied hearts of rats subjected to aortic constriction. It was therefore of interest to determine if these changes were associated with alterations in fatty acid oxidation by the hypertrophied myocardium. Hearts were excised from sham-operated and aortic-constricted rats and perfused at 10 cm H/sub 2/O left atrial filling pressure with a ventricular afterload of 80 cm of H/sub 2/O with buffer containing 1.2 mM /sup 14/C-linoleate. Heart rate and peak systolic pressure were not different in control and hypertrophied hearts. /sup 14/CO/submore » 2/ production was linear in both groups of hearts between 10 and 30 minutes of perfusion. The rate of fatty acid oxidation determined by /sup 14/CO/sub 2/ production during this time was 0.728 +/- 0.06 ..mu..moles/min/g dry in control hearts and 0.710 +/- 0.02 ..mu..moles/min/g dry in hypertrophied hearts. Comparable rates of fatty acid oxidation were associated with comparable rates of O/sub 2/ consumption in the two groups of hearts (39.06 +/- 3.50 and 36.78 +/- 2.39 ..mu..moles/g dry/min for control and hypertrophied hearts, respectively). The data indicate that the ability of the hypertrophied heart to oxidize fatty acids under these perfusion conditions is not impaired in spite of significant reductions in tissue levels of coenzyme A and carnitine.« less
Heart rate profile during exercise in patients with early repolarization.
Cay, Serkan; Cagirci, Goksel; Atak, Ramazan; Balbay, Yucel; Demir, Ahmet Duran; Aydogdu, Sinan
2010-09-01
Both early repolarization and altered heart rate profile are associated with sudden death. In this study, we aimed to demonstrate an association between early repolarization and heart rate profile during exercise. A total of 84 subjects were included in the study. Comparable 44 subjects with early repolarization and 40 subjects with normal electrocardiogram underwent exercise stress testing. Resting heart rate, maximum heart rate, heart rate increment and decrement were analyzed. Both groups were comparable for baseline characteristics including resting heart rate. Maximum heart rate, heart rate increment and heart rate decrement of the subjects in early repolarization group had significantly decreased maximum heart rate, heart rate increment and heart rate decrement compared to control group (all P < 0.05). The lower heart rate increment (< 106 beats/min) and heart rate decrement (< 95 beats/min) were significantly associated with the presence of early repolarization. After adjustment for age and sex, the multiple-adjusted OR of the risk of presence of early repolarization was 2.98 (95%CI 1.21-7.34) (P = 0.018) and 7.73 (95%CI 2.84-21.03) (P < 0.001) for the lower heart rate increment and heart rate decrement compared to higher levels, respectively. Subjects with early repolarization have altered heart rate profile during exercise compared to control subjects. This can be related to sudden death.
Mellecker, R R; McManus, A M
2014-05-01
The current study was designed to evaluate the intensity levels of three exergames and determine the association with physical activity recommendations that correspond to specific outcomes. The variation in cardiovascular responses between the three exergames was also examined. We employed a cross-sectional laboratory design. We recruited 18 girls to participate in a peak VO2 test and to play Gamercize, Kinect River Rush, XaviX J-Mat at three separate exergaming sessions. Linear regression equations of heart rate and percentage of peak VO2 were calculated for each participant to determine the intensity of exergame play. Differences in intensity between the three exergames and time spent in the recommended moderate (heart rate at ≥ 55% peak VO2) and vigorous (heart rate at ≥ 75% peak VO2) intensity levels were analyzed. We calculated the coefficient of variation for the mean heart rate to determine the difference in variance in heart rate values for the three exergames. When playing Gamercize and Kinect the girls did not play at recommended moderate or vigorous levels. Although the girls did not play at vigorous levels when playing XaviX J-Mat, our results showed that when playing XaviX J-Mat they did play at moderate intensity levels. No significant differences in the coefficient of variation between the three exergames were apparent. If active gaming is to be used to increase physical activity levels then individual differences in levels of exertion and specific activity recommendations need to be taken into consideration. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Ivabradine in stable coronary artery disease without clinical heart failure.
Fox, Kim; Ford, Ian; Steg, Philippe Gabriel; Tardif, Jean-Claude; Tendera, Michal; Ferrari, Roberto
2014-09-18
An elevated heart rate is an established marker of cardiovascular risk. Previous analyses have suggested that ivabradine, a heart-rate-reducing agent, may improve outcomes in patients with stable coronary artery disease, left ventricular dysfunction, and a heart rate of 70 beats per minute or more. We conducted a randomized, double-blind, placebo-controlled trial of ivabradine, added to standard background therapy, in 19,102 patients who had both stable coronary artery disease without clinical heart failure and a heart rate of 70 beats per minute or more (including 12,049 patients with activity-limiting angina [class ≥II on the Canadian Cardiovascular Society scale, which ranges from I to IV, with higher classes indicating greater limitations on physical activity owing to angina]). We randomly assigned patients to placebo or ivabradine, at a dose of up to 10 mg twice daily, with the dose adjusted to achieve a target heart rate of 55 to 60 beats per minute. The primary end point was a composite of death from cardiovascular causes or nonfatal myocardial infarction. At 3 months, the mean (±SD) heart rate of the patients was 60.7±9.0 beats per minute in the ivabradine group versus 70.6±10.1 beats per minute in the placebo group. After a median follow-up of 27.8 months, there was no significant difference between the ivabradine group and the placebo group in the incidence of the primary end point (6.8% and 6.4%, respectively; hazard ratio, 1.08; 95% confidence interval, 0.96 to 1.20; P=0.20), nor were there significant differences in the incidences of death from cardiovascular causes and nonfatal myocardial infarction. Ivabradine was associated with an increase in the incidence of the primary end point among patients with activity-limiting angina but not among those without activity-limiting angina (P=0.02 for interaction). The incidence of bradycardia was higher with ivabradine than with placebo (18.0% vs. 2.3%, P<0.001). Among patients who had stable coronary artery disease without clinical heart failure, the addition of ivabradine to standard background therapy to reduce the heart rate did not improve outcomes. (Funded by Servier; SIGNIFY Current Controlled Trials number, ISRCTN61576291.).
Exploring Individual Differences in Workload Assessment
2014-12-26
83 Question 3: Do the physiological measures: blinks, saccades, HR, HRV , correlate with the objective workload profile for all...Electrooculography (EOG) signals, and heart rate (HR) and heart rate variability ( HRV ) as determined from Electrocardiography (ECG...3) Do the physiological measures blinks, saccades, HR, and HRV , correlate with the objective workload profile for all divergent participants and
Use of heart rate variability differentiates between physical and psychological states
USDA-ARS?s Scientific Manuscript database
The major goal of animal welfare scientists is to determine when animals are experiencing a state of good welfare or poor welfare. The goal of this research was to determine if measures of heart rate variability can be used to differentiate whether animals are experiencing differing states of physi...
Metabolic Syndrome and Short-Term Heart Rate Variability in Adults with Intellectual Disabilities
ERIC Educational Resources Information Center
Chang, Yaw-Wen; Lin, Jin-Ding; Chen, Wei-Liang; Yen, Chia-Feng; Loh, Ching-Hui; Fang, Wen-Hui; Wu, Li-Wei
2012-01-01
Metabolic syndrome (MetS) increases the risk of cardiovascular events. Heart rate variability (HRV) represents autonomic functioning, and reduced HRV significantly increases cardiovascular mortality. The aims of the present paper are to assess the prevalence of MetS in adults with intellectual disabilities (ID), the difference in short-term HRV…
Albanese, Antonio; Limei Cheng; Ursino, Mauro; Chbat, Nicolas W
2015-01-01
Apnea via breath-holding (BH) in air induces cardiorespiratory adaptation that involves the activation of several reflex mechanisms and their complex interactions. Hence, the effects of BH in air on cardiorespiratory function can become hardly predictable and difficult to be interpreted. Particularly, the effect on heart rate is not yet completely understood because of the contradicting results of different physiological studies. In this paper we apply our previously developed cardiopulmonary model (CP Model) to a scenario of BH with a twofold intent: (1) further validating the CP Model via comparison against experimental data; (2) gaining insights into the physiological reasoning for such contradicting experimental results. Model predictions agreed with published experimental animal and human data and indicated that heart rate increases during BH in air. Changes in the balance between sympathetic and vagal effects on heart rate within the model proved to be effective in inverting directions of the heart rate changes during BH. Hence, the model suggests that intra-subject differences in such sympatho-vagal balance may be one of the reasons for the contradicting experimental results.
Asymmetric acceleration/deceleration dynamics in heart rate variability
NASA Astrophysics Data System (ADS)
Alvarez-Ramirez, J.; Echeverria, J. C.; Meraz, M.; Rodriguez, E.
2017-08-01
The heart rate variability (HRV) is an important physiological signal used either to assess the risk of cardiac death or to model the cardiovascular regulatory dynamics. Asymmetries in HRV data have been observed using 2D Poincare plots, which have been linked to a non-equilibrium operation of the cardiac autonomic system. This work further explores the presence of asymmetries but in the serial correlations of the dynamics of HRV data. To this end, detrended fluctuation analysis (DFA) was used to estimate the Hurst exponent both when the heart rate is accelerating and when it is decelerating. The analysis is conducted using data collected from subjects under normal sinus rhythm (NSR), congestive heart failure (CHF) and atrial fibrillation (AF) . For the NSR cases, it was found that correlations are stronger (p < 0 . 05) when the heart rate is accelerating than when it is decelerating over different scales in the range 20-40 beats. In contrast, the opposite behavior was detected for the CHF and AF patients. Possible links between asymmetric correlations in the dynamics and the mechanisms controlling the operation of the heart rate are discussed, as well as their implications for modeling the cardiovascular regulatory dynamics.
Nillni, Yael I; Berenz, Erin C; Rohan, Kelly J; Zvolensky, Michael J
2012-01-01
The current study examined sex differences in psychological (i.e., self-reported anxiety, panic symptoms, and avoidance) and physiological (i.e., heart rate and skin conductance level) response to, and recovery from, a laboratory biological challenge. Participants were a community-recruited sample of 128 adults (63.3% women; M(age)=23.2 years, SD=8.9) who underwent a 4-min 10% CO(2)-enriched air biological challenge. As predicted, women reported more severe physical panic symptoms and avoidance (i.e., less willingness to participate in another challenge) and demonstrated increased heart rate as compared to men above and beyond the variance accounted for by other theoretically relevant variables (recent panic attack history, neuroticism, and anxiety sensitivity). Additionally, women demonstrated a faster rate of recovery with respect to heart rate compared to men. These results are in line with literature documenting sex-specific differences in panic psychopathology, and results are discussed in the context of possible mechanisms underlying sex differences in panic vulnerability. Copyright © 2011 Elsevier Ltd. All rights reserved.
Association of heart rate profile during exercise with the severity of coronary artery disease.
Cay, Serkan; Ozturk, Sezgin; Biyikoglu, Funda; Yildiz, Abdulkadir; Cimen, Tolga; Uygur, Belma; Tuna, Funda
2009-05-01
Coronary artery disease is the leading cause of morbidity and mortality around the world. Autonomic nervous system abnormalities are associated with coronary artery disease and its complications. Exercise stress tests are routinely used for the detection of the presence of coronary artery disease. In this study, we observed the association between heart rate profile during exercise and the severity of coronary artery disease. One hundred and sixty patients with abnormal exercise treadmill test (> or =1 mm horizontal or downsloping ST-segment depression; 119 men, 41 women; mean age = 57 +/- 9 years) were included in the study. Use of any drug affecting heart rate was not permitted. Resting heart rate before exercise, maximum heart rate during exercise, and resting heart rate after exercise (5 min later) were measured and two parameters were calculated: heart rate increment (maximum heart rate - resting heart rate before exercise) and heart rate decrement (maximum heart rate - resting heart rate after exercise). All patients underwent selective coronary angiography and subclassified into two groups according to stenotic lesion severity. Group 1 had at least 50% of stenotic lesion and group 2 had less than 50%. Patients in the first group had increased resting heart rate, decreased maximum heart rate, decreased heart rate increment, and decreased heart rate decrement compared with second group. All patients were classified into tertiles of resting heart rate, heart rate increment, and heart rate decrement level to evaluate whether these parameters were associated with severity of coronary artery stenosis in the study. The multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 21.888 (95% confidence interval 6.983-68.606) for the highest tertile of resting heart rate level compared with the lowest tertile. In addition, the multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 20.987 (95% confidence interval 6.635-66.387) for the lowest tertile of heart rate increment level compared with the highest tertile and 2.360 (95% confidence interval 1.004-5.544) for the lowest tertile of heart rate decrement level compared with the highest tertile. Altered autonomic nervous system regulation affects heart rate profile, increased resting heart rate, decreased heart rate increment, and decreased heart rate decrement, during exercise and this effect is strongly and independently associated with the severity of coronary artery disease.
Rowlands, Derek J
2012-01-01
The QT interval on the electrocardiogram is an increasingly important measurement, especially in relation to drug action and interaction. The QT interval varies inversely as the heart rate and numerous rate correction formulae have been proposed. It is difficult to compare the effect of applying different formulae at different heart rates and for different measured QT intervals. A simple graphical display of the results from different formulae is proposed. This display is dependent on the concept of the absolute correction factor. This graphical presentation is useful (a) in comparing the effect of the application of different formulae and (b) in directly reading the correction produced by any individual formula. Copyright © 2012 Elsevier Inc. All rights reserved.
Aerobic Exercise during Pregnancy and Presence of Fetal-Maternal Heart Rate Synchronization
Van Leeuwen, Peter; Gustafson, Kathleen M.; Cysarz, Dirk; Geue, Daniel; May, Linda E.; Grönemeyer, Dietrich
2014-01-01
It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. Methods In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. Results In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. Conclusion The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates. PMID:25162592
Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.
Van Leeuwen, Peter; Gustafson, Kathleen M; Cysarz, Dirk; Geue, Daniel; May, Linda E; Grönemeyer, Dietrich
2014-01-01
It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.
The Influence of Bearing-Down Technique on the Fetal Heart Rate during the Second Stage of Labor.
NASA Astrophysics Data System (ADS)
Perlis, Deborah Woolley
This experimental study contrasted the effects of sustained bearing-down efforts with short bearing-down efforts during the first twelve contractions of the second stage of labor. A single subject design with intrasubject replication was used to compare the incidence, duration, and amplitude of fetal heart rate decelerations, as well as the beat-to-beat variability of those decelerations. Neonatal outcome was evaluated with umbilical arterial cord blood pH values and the one- and five-minute APGAR scores. Thirty -two nulliparous women alternated the use of vigorous, sustained Valsalva-style bearing-down efforts with shorter efforts called minipushes every three contractions during the second stage of labor. Sixteen women began the second stage using the Valsalva-style bearing-down technique; sixteen began the second stage using the minipush. The fetal heart rate was recorded by an internal fetal scalp electrode. Uterine contractility was measured by an internal uterine pressure catheter. A repeated-measures MANOVA showed a significant interaction between the order of implementation of the bearing-down techniques and the amplitude of the fetal heart rate decelerations. A similar comparison of the duration of the decelerations showed no significant differences between the two bearing-down techniques. Likewise, analysis of the incidence of fetal heart rate decelerations and the magnitude of the beat-to-beat variability revealed no significant differences between the two techniques.
Enhancing treatment effectiveness through social modelling: A pilot study.
Faasse, Kate; Perera, Anna; Loveys, Kate; Grey, Andrew; Petrie, Keith J
2017-05-01
Medical treatments take place in social contexts; however, little research has investigated how social modelling might influence treatment outcomes. This experimental pilot study investigated social modelling of treatment effectiveness and placebo treatment outcomes. Fifty-nine participants took part in the study, ostensibly examining the use of beta-blockers (actually placebos) for examination anxiety. Participants were randomly assigned to observe a female confederate report positive treatment effects (reduced heart rate, relaxed, calm) or feeling no different. Heart rate, anxiety and blood pressure were assessed, as were symptoms and attributed side effects. Heart rate decreased significantly more in the social modelling compared to control condition, p = .027 (d = .63), and there were trends towards effects in the same direction for both anxiety, p = .097 (d = .46), and systolic blood pressure, p = .077 (d = .51). Significant pre-post placebo differences in heart rate, anxiety and diastolic blood pressure were found in the social modelling group, ps < .007 (ds = .77-1.37), but not the control condition, ps > .28 (ds = .09-.59). Social observation of medication effectiveness enhanced placebo effectiveness in heart rate, and showed a trend towards enhancing treatment effectiveness in both anxiety and systolic blood pressure. Social modelling may have utility in enhancing the effectiveness of many active medical treatments.
Heart transplant outcomes in recipients of Centers for Disease Control (CDC) high risk donors.
Tsiouris, Athanasios; Wilson, Lynn; Sekar, Rajesh B; Mangi, Abeel A; Yun, James J
2016-12-01
A lack of donor hearts remains a major limitation of heart transplantation. Hearts from Centers for Disease Control (CDC) high-risk donors can be utilized with specific recipient consent. However, outcomes of heart transplantation with CDC high-risk donors are not well known. We sought to define outcomes, including posttransplant hepatitis and human immunodeficiency virus (HIV) status, in recipients of CDC high-risk donor hearts at our institution. All heart transplant recipients from August 2010 to December 2014 (n = 74) were reviewed. Comparison of 1) CDC high-risk donor (HRD) versus 2) standard-risk donor (SRD) groups were performed using chi-squared tests for nominal data and Wilcoxon two-sample tests for continuous variables. Survival was estimated with Kaplan-Meier curves. Of 74 heart transplant recipients reviewed, 66 (89%) received a SRD heart and eight (11%) received a CDC HRD heart. We found no significant differences in recipient age, sex, waiting list 1A status, pretransplant left ventricular assist device (LVAD) support, cytomegalovirus (CMV) status, and graft ischemia times (p = NS) between the HRD and SRD groups. All of the eight HRD were seronegative at the time of transplant. Postoperatively, there was no significant difference in rejection rates at six and 12 months posttransplant. Importantly, no HRD recipients acquired hepatitis or HIV. Survival in HRD versus SRD recipients was not significantly different by Kaplan-Meier analysis (log rank p = 0.644) at five years posttransplant. Heart transplants that were seronegative at the time of transplant had similar posttransplant graft function, rejection rates, and five-year posttransplant survival versus recipients of SRD hearts. At our institution, no cases of hepatitis or HIV occurred in HRD recipients in early follow-up. © 2016 Wiley Periodicals, Inc.
Heart rate detection from an electronic weighing scale.
González-Landaeta, R; Casas, O; Pallàs-Areny, R
2007-01-01
We propose a novel technique for heart rate detection on a subject that stands on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear, and does not require any sensors attached to the body. We have applied our method to three different weighing scales, and estimated whether their sensitivity and frequency response suited heart rate detection. Scale sensitivities were from 490 nV/V/N to 1670 nV/V/N, all had an underdamped transient response and their dynamic gain error was below 19% at 10 Hz, which are acceptable values for heart rate estimation. We also designed a pulse detection system based on off-the-shelf integrated circuits, whose gain was about 70x10(3) and able to sense force variations about 240 mN. The signal-to-noise ratio (SNR) of the main peaks of the pulse signal detected was higher than 48 dB, which is large enough to estimate the heart rate by simple signal processing methods. To validate the method, the ECG and the force signal were simultaneously recorded on 12 volunteers. The maximal error obtained from heart rates determined from these two signals was +/-0.6 beats/minute.
Do former preterm infants remember and respond to neonatal intensive care unit noise?
Barreto, Edwin D; Morris, Brenda H; Philbin, M Kathleen; Gray, Lincoln C; Lasky, Robert E
2006-11-01
Previous studies have shown that 4-month-old infants have a decrease in heart rate, a component of the orienting reflex, in response to interesting auditory stimuli and an increase in heart rate to aversive auditory stimuli. To compare the heart rate responses of former preterm and term infants at 4-5 months corrected age to a recording of NICU noises. 13 former preterm infants and 17 full-term infants were presented NICU noise and another noise of similar level and frequency content in random order. Heart rate 10s prior to the stimulus and for 20s during the stimulus was analyzed. Group differences in second by second heart rate changes in response to the two noise stimuli were compared by analysis of covariance. Both the preterm and term newborns responded similarly to the NICU noise and the control noise. The preterm infants did not alter their heart rate in response to either stimulus. In contrast, the term infants displayed an orienting response to the second stimulus presented regardless of whether it was the NICU or control noise. Former preterm infants at 4-5 months corrected age have reduced responsiveness to auditory stimulation in comparison to 4- to 5-month-old term infants. Furthermore, they did not respond to the NICU noise as an aversive stimulus.
Wavelet and receiver operating characteristic analysis of heart rate variability
NASA Astrophysics Data System (ADS)
McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.
2002-02-01
Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.
Metabolic circadian rhythms in embryonic turtles.
Loudon, Fiona Kay; Spencer, Ricky-John; Strassmeyer, Alana; Harland, Karen
2013-07-01
Oviparous species are model organisms for investigating embryonic development of endogenous physiological circadian rhythms without the influence of maternal biorhythms. Recent studies have demonstrated that heart rates and metabolic rates of embryonic turtles are not constant or always maximal and can be altered in response to the presence of embryos at a more advanced stage of development within the nest. A first step in understanding the physiological mechanisms underpinning these responses in embryonic ectothermic organisms is to develop metabolic profiles (e.g., heart rate) at different temperatures throughout incubation. Heart beat and rhythmic patterns or changes in development may represent important signals or cues within a nest and may be vital to coordinate synchronous hatching well in advance of the final stages of incubation. We developed baseline embryonic heart-rate profiles of embryos of the short-necked Murray River turtle (Emydura macquarii) to determine the stage of embryogenesis that metabolic circadian rhythms become established, if at all. Eggs were incubated at constant temperatures (26°C and 30°C) and heart rates were monitored at 6-h intervals over 24 h every 7-11 days until hatching. Circadian heart rate rhythms were detected at the mid-gestation period and were maintained until hatching. Heart rates throughout the day varied by up to 20% over 24 h and were not related to time of day. This study demonstrated that endogenous metabolic circadian rhythms in developing embryos in turtle eggs establish earlier in embryogenesis than those documented in other vertebrate taxa during embryogenesis. Early establishment of circadian rhythms in heart rates may be critical for communication among embryos and synchrony in hatching and emergence from the nest.
Job strain and resting heart rate: a cross-sectional study in a Swedish random working sample.
Eriksson, Peter; Schiöler, Linus; Söderberg, Mia; Rosengren, Annika; Torén, Kjell
2016-03-05
Numerous studies have reported an association between stressing work conditions and cardiovascular disease. However, more evidence is needed, and the etiological mechanisms are unknown. Elevated resting heart rate has emerged as a possible risk factor for cardiovascular disease, but little is known about the relation to work-related stress. This study therefore investigated the association between job strain, job control, and job demands and resting heart rate. We conducted a cross-sectional survey of randomly selected men and women in Västra Götalandsregionen, Sweden (West county of Sweden) (n = 1552). Information about job strain, job demands, job control, heart rate and covariates was collected during the period 2001-2004 as part of the INTERGENE/ADONIX research project. Six different linear regression models were used with adjustments for gender, age, BMI, smoking, education, and physical activity in the fully adjusted model. Job strain was operationalized as the log-transformed ratio of job demands over job control in the statistical analyses. No associations were seen between resting heart rate and job demands. Job strain was associated with elevated resting heart rate in the unadjusted model (linear regression coefficient 1.26, 95 % CI 0.14 to 2.38), but not in any of the extended models. Low job control was associated with elevated resting heart rate after adjustments for gender, age, BMI, and smoking (linear regression coefficient -0.18, 95 % CI -0.30 to -0.02). However, there were no significant associations in the fully adjusted model. Low job control and job strain, but not job demands, were associated with elevated resting heart rate. However, the observed associations were modest and may be explained by confounding effects.
Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?
Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J
2017-07-01
For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P < .001, R 2 = .67, SEE = 2.78). HRR after a standardized warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gunter, Thomas E., E-mail: thomas_gunter@urmc.rochester.ed; Gerstner, Brent, E-mail: brent_gerstner@urmc.rochester.ed; Lester, Tobias, E-mail: Tlester200@gmail.co
2010-11-15
Manganese (Mn) toxicity is partially mediated by reduced ATP production. We have used oxidation rate assays-a measure of ATP production-under rapid phosphorylation conditions to explore sites of Mn{sup 2+} inhibition of ATP production in isolated liver, brain, and heart mitochondria. This approach has several advantages. First, the target tissue for Mn toxicity in the basal ganglia is energetically active and should be studied under rapid phosphorylation conditions. Second, Mn may inhibit metabolic steps which do not affect ATP production rate. This approach allows identification of inhibitions that decrease this rate. Third, mitochondria from different tissues contain different amounts of themore » components of the metabolic pathways potentially resulting in different patterns of ATP inhibition. Our results indicate that Mn{sup 2+} inhibits ATP production with very different patterns in liver, brain, and heart mitochondria. The primary Mn{sup 2+} inhibition site in liver and heart mitochondria, but not in brain mitochondria, is the F{sub 1}F{sub 0} ATP synthase. In mitochondria fueled by either succinate or glutamate + malate, ATP production is much more strongly inhibited in brain than in liver or heart mitochondria; moreover, Mn{sup 2+} inhibits two independent sites in brain mitochondria. The primary site of Mn-induced inhibition of ATP production in brain mitochondria when succinate is substrate is either fumarase or complex II, while the likely site of the primary inhibition when glutamate plus malate are the substrates is either the glutamate/aspartate exchanger or aspartate aminotransferase.« less
Pirhadi, Masume; Valiani, Mahboube
2017-01-01
One of the main goals of antenatal testing is to identify fetuses at the risk of neurologic injury or death so that these adverse outcomes can be prevented. We want to assess the effects of BL67 points' stimulation on fetal heart rate parameters and fetal movements during nonstress test (NST). We did a quasi-experimental design in Shahid Beheshti Hospital in Isfahan in 2011. This study aims to assessment of the effects of BL67 points' stimulation on fetal heart rate parameters and fetal movements. We did a randomized controlled clinical trial in Shahid Beheshti Hospital in Isfahan in 2011. This study is a quasi-experimental design that was conducted in one group and the two steps (before-after study). Participants were pregnant women (primigravida) who were 35-18 years that refer to Shahid Beheshti Hospital in Isfahan in 2011 to receive routine prenatal care. The 32 pregnant women were selected for acupressure during the second NST. The statistical processing was performed by descriptive, paired t -test through SPSS version 20. There was no significant difference in mean number of accelerations in fetal heart rate and mean number of fetal movement before and after intervention; however, there was a significant difference in mean time to the second acceleration before and after the intervention ( P = 0.04). No difference between parameters of the fetal heart rate before and after stimulation and lack of uterine response by this method is a significant advantage and is probably why stimulating this point could not create a risk to the fetuses.
Speed and heart-rate profiles in skating and classical cross-country skiing competitions.
Bolger, Conor M; Kocbach, Jan; Hegge, Ann Magdalen; Sandbakk, Øyvind
2015-10-01
To compare the speed and heart-rate profiles during international skating and classical competitions in male and female world-class cross-country skiers. Four male and 5 female skiers performed individual time trials of 15 km (men) and 10 km (women) in the skating and classical techniques on 2 consecutive days. Races were performed on the same 5-km course. The course was mapped with GPS and a barometer to provide a valid course and elevation profile. Time, speed, and heart rate were determined for uphill, flat, and downhill terrains throughout the entire competition by wearing a GPS and a heart-rate monitor. Times in uphill, flat, and downhill terrain were ~55%, 15-20%, and 25-30%, respectively, of the total race time for both techniques and genders. The average speed differences between skating and classical skiing were 9% and 11% for men and women, respectively, and these values were 12% and 15% for uphill, 8% and 13% for flat (all P < .05), and 2% and 1% for downhill terrain. The average speeds for men were 9% and 11% faster than for women in skating and classical, respectively, with corresponding numbers of 11% and 14% for uphill, 6% and 11% for flat, and 4% and 5% for downhill terrain (all P < .05). Heart-rate profiles were relatively independent of technique and gender. The greatest performance differences between the skating and classical techniques and between the 2 genders were found on uphill terrain. Therefore, these speed differences could not be explained by variations in exercise intensity.
Sims, J; Carroll, D
1990-03-01
Heart rate, systolic and diastolic blood pressure, and respiratory and metabolic activity were recorded prior to and during mental arithmetic and a video game task in 20 young men with mildly elevated casual systolic blood pressures. Twenty-five unambiguously normotensive young men were tested under the same protocol. For pretask baseline physiological activity, group differences emerged for all cardiovascular and metabolic variables; thus the elevated blood pressure group displayed not only higher resting cardiovascular levels than normotensive subjects, but higher levels of metabolic activity too. With regard to change in physiological activity from rest to task, the group with mildly elevated blood pressure showed reliably larger increases in heart rate to the mental arithmetic task than the normotensive subjects. These effects, however, were not paralleled by group differences in metabolic activity increase. Physiological measures were also taken prior to and during graded dynamic exercise. The subsequent calculation of individual heart rate-oxygen consumption exercise regression lines allowed the comparison of actual and predicted heart rates during psychological challenge. The subjects with mildly elevated blood pressure displayed significantly greater discrepancies between actual and predicted heart rate values than normotensives during the psychological tasks in general and mental arithmetic in particular. Group differences in physiological activity during exercise largely reflected the pattern seen at rest. A possible exception here was systolic blood pressure. Not only were systolic blood pressure levels higher throughout the exercise phase for mildly elevated blood pressure subjects, but this group evidenced more of an increase from rest to exercise than the normotensives.
NASA Astrophysics Data System (ADS)
Vyhnalek, Brian; Zurcher, Ulrich; O'Dwyer, Rebecca; Kaufman, Miron
2009-10-01
A wide range of heart rate irregularities have been reported in small studies of patients with temporal lobe epilepsy [TLE]. We hypothesize that patients with TLE display cardiac dysautonomia in either a subclinical or clinical manner. In a small study, we have retrospectively identified (2003-8) two groups of patients from the epilepsy monitoring unit [EMU] at the Cleveland Clinic. No patients were diagnosed with cardiovascular morbidities. The control group consisted of patients with confirmed pseudoseizures and the experimental group had confirmed right temporal lobe epilepsy through a seizure free outcome after temporal lobectomy. We quantified the heart rate variability using the approximate entropy [ApEn]. We found similar values of the ApEn in all three states of consciousness (awake, sleep, and proceeding seizure onset). In the TLE group, there is some evidence for greater variability in the awake than in either the sleep or proceeding seizure onset. Here we present results for mathematically-generated time series: the heart rate fluctuations ξ follow the γ statistics i.e., p(ξ)=γ-1(k) ξ^k exp(-ξ). This probability function has well-known properties and its Shannon entropy can be expressed in terms of the γ-function. The parameter k allows us to generate a family of heart rate time series with different statistics. The ApEn calculated for the generated time series for different values of k mimic the properties found for the TLE and pseudoseizure group. Our results suggest that the ApEn is an effective tool to probe differences in statistics of heart rate fluctuations.
Bogucki, Sz; Noszczyk-Nowak, A
2017-03-28
Heart rate variability is an established risk factor for mortality in both healthy dogs and animals with heart failure. The aim of this study was to compare short-term heart rate variability (ST-HRV) parameters from 60-min electrocardiograms in dogs with sick sinus syndrome (SSS, n=20) or chronic mitral valve disease (CMVD, n=20) and healthy controls (n=50), and to verify the clinical application of ST-HRV analysis. The study groups differed significantly in terms of both time - and frequency- domain ST-HRV parameters. In the case of dogs with SSS and healthy controls, particularly evident differences pertained to HRV parameters linked directly to the variability of R-R intervals. Lower values of standard deviation of all R-R intervals (SDNN), standard deviation of the averaged R-R intervals for all 5-min segments (SDANN), mean of the standard deviations of all R-R intervals for all 5-min segments (SDNNI) and percentage of successive R-R intervals >50 ms (pNN50) corresponded to a decrease in parasympathetic regulation of heart rate in dogs with CMVD. These findings imply that ST-HRV may be useful for the identification of dogs with SSS and for detection of dysautonomia in animals with CMVD.
Lee, Jae Eun; Kim, Bum Soo; Park, Wan; Huh, Jung Kwon; Kim, Byung Jin; Sung, Ki Chul; Kang, Jin Ho; Lee, Man Ho; Park, Jung Ro
2010-04-01
The correlation between brain natruretic peptide (BNP) level and cardiac autonomic function has been studied in type 2 diabetic patients. However, there is limited data from patients with normal systolic function. We evaluated the association between heart rate recovery (HRR) representing autonomic dysfunction and three plasma BNP levels: pre-exercise, post-exercise, and change during exercise in patients with normal systolic function. Subjects included 105 patients with chest pain and normal systolic function. HRR was defined as the difference between the peak heart rate and the rate measured two minutes after completion of a treadmill exercise test. We measured plasma BNP levels before exercise, 5 minutes after completion of exercise, and during exercise (absolute value of difference between pre- and post-exercise BNP levels). Patients with abnormal HRR values (=24 beats for the first 2 minutes of HRR) had lower high-density lipoprotein, lower peak heart rates, and higher pre- and post-exercise BNP levels than patients with normal HRR values. The patients with coronary artery disease (CAD) had abnormal HRR. However, no significant differences were found between the two groups in terms of history of hypertension (HTN), diabetes, and peak systolic blood pressure (SBP) and diastolic blood pressure (DBP). HRR was significantly associated with pre-exercise BNP (r=-0.36, p=0.004) and post-exercise BNP (r=-0.27, p=0.006), but not BNP changes. Further, pre-exercise BNP levels showed a greater association with HRR than post-exercise BNP levels. HRR is independently associated with pre-exercise and post-exercise BNP levels, even in patients with normal systolic function.
Sobieszczańska-Małek, Małgorzata; Zieliński, Tomasz; Rywik, Tomasz; Piotrowska, Małgorzata; Religa, Grzegorz; Przybyłowski, Piotr; Rózański, Jacek; Korewicki, Jerzy
2010-01-01
Atrial fibrillation (AF) is the most common arrhythmia among patients (pts) with heart failure and has significant influence on survival. to assess prognosis of pts with refractory heart failure (HF) qualified for heart transplantation (HTX). 872 pts (107 W and 765 M) were qualified for HTX between Dec 2003 and Oct 2007. Patient's death or super urgent heart transplantation were considered the end point in Kaplan-Meier survival curves. 680 pts were on sinus rhythm (SR) and 192(22.0%) had atrial fibrillation (AF). During follow-up (1-1464 days, mean 550 days) 155 pts (17.7%) died, 17.65% with SR and 18.23% with AF (ns). EF - mean 21,6 (SR) and 21,8 (FA), NYHA 3,1 (SR), NTproBNP- mean 3635, 4 (SR) and 4349,4 (FA), Arronson - mean 7,8 (SR) and 7,7 (FA). There were no significant differences between groups. We analyzed influence of heart rate (Kaplan-Maier method) on survival. The pts were divided according to HR: gr.I <70/min, gr II 71-89/min, gr III >90/min. The shortest survival rate was noticed in group III. There was no difference in survival between group I and II. The prognosis for patients qualified for heart transplant does not depend on the type of the dominant cardiac rhythm (atrial fibrillation or sinus rhythm). The prognosis is significantly better for those patients whose basic, resting heart rate does not exceed 90 bpm regardless of the rhythm type.
Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander
2018-01-01
A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3-5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To overcome current knowledge deficits and methodological inconsistencies, future investigations should systematically evaluate the validity and usefulness of the various approaches available to guide and improve the implementation of decision-support systems in (team) sports practice.
Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander
2018-01-01
A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3–5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To overcome current knowledge deficits and methodological inconsistencies, future investigations should systematically evaluate the validity and usefulness of the various approaches available to guide and improve the implementation of decision-support systems in (team) sports practice. PMID:29904351
Herzig, David; Eser, Prisca; Radtke, Thomas; Wenger, Alina; Rusterholz, Thomas; Wilhelm, Matthias; Achermann, Peter; Arhab, Amar; Jenni, Oskar G.; Kakebeeke, Tanja H.; Leeger-Aschmann, Claudia S.; Messerli-Bürgy, Nadine; Meyer, Andrea H.; Munsch, Simone; Puder, Jardena J.; Schmutz, Einat A.; Stülb, Kerstin; Zysset, Annina E.; Kriemler, Susi
2017-01-01
Background: Recent studies have claimed a positive effect of physical activity and body composition on vagal tone. In pediatric populations, there is a pronounced decrease in heart rate with age. While this decrease is often interpreted as an age-related increase in vagal tone, there is some evidence that it may be related to a decrease in intrinsic heart rate. This factor has not been taken into account in most previous studies. The aim of the present study was to assess the association between physical activity and/or body composition and heart rate variability (HRV) independently of the decline in heart rate in young children. Methods: Anthropometric measurements were taken in 309 children aged 2–6 years. Ambulatory electrocardiograms were collected over 14–18 h comprising a full night and accelerometry over 7 days. HRV was determined of three different night segments: (1) over 5 min during deep sleep identified automatically based on HRV characteristics; (2) during a 20 min segment starting 15 min after sleep onset; (3) over a 4-h segment between midnight and 4 a.m. Linear models were computed for HRV parameters with anthropometric and physical activity variables adjusted for heart rate and other confounding variables (e.g., age for physical activity models). Results: We found a decline in heart rate with increasing physical activity and decreasing skinfold thickness. HRV parameters decreased with increasing age, height, and weight in HR-adjusted regression models. These relationships were only found in segments of deep sleep detected automatically based on HRV or manually 15 min after sleep onset, but not in the 4-h segment with random sleep phases. Conclusions: Contrary to most previous studies, we found no increase of standard HRV parameters with age, however, when adjusted for heart rate, there was a significant decrease of HRV parameters with increasing age. Without knowing intrinsic heart rate correct interpretation of HRV in growing children is impossible. PMID:28286485
Herzig, David; Eser, Prisca; Radtke, Thomas; Wenger, Alina; Rusterholz, Thomas; Wilhelm, Matthias; Achermann, Peter; Arhab, Amar; Jenni, Oskar G; Kakebeeke, Tanja H; Leeger-Aschmann, Claudia S; Messerli-Bürgy, Nadine; Meyer, Andrea H; Munsch, Simone; Puder, Jardena J; Schmutz, Einat A; Stülb, Kerstin; Zysset, Annina E; Kriemler, Susi
2017-01-01
Background: Recent studies have claimed a positive effect of physical activity and body composition on vagal tone. In pediatric populations, there is a pronounced decrease in heart rate with age. While this decrease is often interpreted as an age-related increase in vagal tone, there is some evidence that it may be related to a decrease in intrinsic heart rate. This factor has not been taken into account in most previous studies. The aim of the present study was to assess the association between physical activity and/or body composition and heart rate variability (HRV) independently of the decline in heart rate in young children. Methods: Anthropometric measurements were taken in 309 children aged 2-6 years. Ambulatory electrocardiograms were collected over 14-18 h comprising a full night and accelerometry over 7 days. HRV was determined of three different night segments: (1) over 5 min during deep sleep identified automatically based on HRV characteristics; (2) during a 20 min segment starting 15 min after sleep onset; (3) over a 4-h segment between midnight and 4 a.m. Linear models were computed for HRV parameters with anthropometric and physical activity variables adjusted for heart rate and other confounding variables (e.g., age for physical activity models). Results: We found a decline in heart rate with increasing physical activity and decreasing skinfold thickness. HRV parameters decreased with increasing age, height, and weight in HR-adjusted regression models. These relationships were only found in segments of deep sleep detected automatically based on HRV or manually 15 min after sleep onset, but not in the 4-h segment with random sleep phases. Conclusions: Contrary to most previous studies, we found no increase of standard HRV parameters with age, however, when adjusted for heart rate, there was a significant decrease of HRV parameters with increasing age. Without knowing intrinsic heart rate correct interpretation of HRV in growing children is impossible.
Control of skin blood flow, sweating, and heart rate - Role of skin vs. core temperature
NASA Technical Reports Server (NTRS)
Wyss, C. R.; Brengelmann, G. L.; Johnson, J. M.; Rowell, L. B.; Niederberger, M.
1974-01-01
A study was conducted to generate quantitative expressions for the influence of core temperature, skin temperature, and the rate of change of skin temperature on sweat rate, skin blood flow, and heart rate. A second goal of the study was to determine whether the use of esophageal temperature rather than the right atrial temperature as a measure of core temperature would lead to different conclusions about the control of measured effector variables.
Impact of space weather on human heart rate during the years 2011-2013
NASA Astrophysics Data System (ADS)
Galata, E.; Ioannidou, S.; Papailiou, M.; Mavromichalaki, H.; Paravolidakis, K.; Kouremeti, M.; Rentifis, L.; Simantirakis, E.; Trachanas, K.
2017-08-01
During the last years a possible link between different levels of solar and geomagnetic disturbances and human physiological parameters is suggested by several published studies. In this work the examination of the potential association between heart rate variations and specific space weather activities was performed. A total of 482 individuals treated at Hippocratio General Hospital in Athens, the Cardiology clinics of Nikaia General Hospital in Piraeus and the Heraklion University Hospital in Crete, Greece, were assessed from July 2011 to April 2013. The heart rate of the individuals was recorded by a Holter monitor on a n hourly basis, while the hourly variations of the cosmic ray intensity measured by the Neutron Monitor Station of the Athens University and of the geomagnetic index Dst provided by the Kyoto Observatory were used. The ANalysis Of VAriance (ANOVA) and the Multiple Linear Regression analysis were used for analysis of these data. A statistically significant effect of both cosmic rays and geomagnetic activity on heart rate was observed, which may indicate that changes in space weather could be linked to heart rate variations.
Diminished heart rate complexity in adolescent girls: a sign of vulnerability to anxiety disorders?
Fiol-Veny, Aina; De la Torre-Luque, Alejandro; Balle, Maria; Bornas, Xavier
2018-07-01
Diminished heart rate variability has been found to be associated with high anxiety symptomatology. Since adolescence is the period of onset for many anxiety disorders, this study aimed to determine sex- and anxiety-related differences in heart rate variability and complexity in adolescents. We created four groups according to sex and anxiety symptomatology: high-anxiety girls (n = 24) and boys (n = 25), and low-anxiety girls (n = 22) and boys (n = 24) and recorded their cardiac function while they performed regular school activities. A series of two-way (sex and anxiety) MANOVAs were performed on time domain variability, frequency domain variability, and non-linear complexity. We obtained no multivariate interaction effects between sex and anxiety, but highly anxious participants had lower heart rate variability than the low-anxiety group. Regarding sex, girls showed lower heart rate variability and complexity than boys. The results suggest that adolescent girls have a less flexible cardiac system that could be a marker of the girls' vulnerability to developing anxiety disorders.
Khvedelidze, M; Chitanava, E; Nadareishvili, D; Jiqia, G; Gvasalia, M
2007-05-01
Effects of low ethanol doses on the vagosympathetic mechanisms of heart rate regulation were studied in rabbits. Analysis of heart rate variability showed that single intravenous administration of 0.5 mg/kg ethanol caused a higher probability of heart electrophysiological instability in sympathicotonics in contrast to vagotonics. This was associated with activation of the whole complex of regulatory mechanisms. In vagotonics, perturbations in power spectrum indicated on rapidly shunting of regulatory activity from lower to high levels of regulatory mechanisms to realize a "first class" undifferentiated response on stress induction. Sympathicotonics were unready to ethanol intravenous administration that resulted in reduction of all spectral component. Intravenous administration of ethanol caused a higher probability of heart electrophysiological instability in sympathicotonics then in vagotonics. It is important to consider these differences for therapeutic application of ethanol to some acute poisoning (methyl alcohol, ethylene glycol).
Liu, Jie; Liu, Zhao-Qian; Tan, Zhi-Rong; Chen, Xiao-Ping; Wang, Lian-Sheng; Zhou, Gan; Zhou, Hong-Hao
2003-10-01
Our objectives were to determine whether the Gly389 polymorphism of the beta(1)-adrenergic receptor exhibits reduced responsiveness in vivo and to test the hypothesis that the Gly389Arg polymorphism affects the blood pressure and heart rate response to metoprolol. beta(1)-Adrenergic receptor genotype was determined by polymerase chain reaction-restriction fragment length polymorphism assay. Exercise-induced heart rate increases were compared to determine the functional significance in vivo in 8 healthy Chinese men homozygous for Gly389 and 8 homozygous for Arg389. All of the subjects were given 25, 50, or 75 mg of metoprolol every 8 hours; the dosages were given in a random order, and each dosage was given for 1 day. The degree of beta-blockade was measured as the reduction in resting and exercise heart rates and blood pressures. Plasma metoprolol concentrations were measured by the use of HPLC-fluorescence detection. Exercise led to a workload-dependent increase in heart rate. There were no differences in exercise-induced heart rate increases between Arg389 and Gly389 homozygotes. Oral metoprolol caused significant dose-dependent decreases in both resting and exercise heart rates in both groups. The reductions in the resting heart rate in 3 dosage levels of metoprolol were 6.3% +/- 0.8% versus 4.1% +/- 0.7%, 10.1% +/- 1.0% versus 6.2% +/- 1.1%, and 14.4% +/- 1.4% versus 10.9% +/- 1.3% in homozygous Arg389 subjects and Gly389 subjects, respectively (P =.008). We also found differences with respect to the exercise heart rate (8.9% +/- 0.5%, 14.0% +/- 0.9%, and 20.1% +/- 1.5% in Arg389 subjects and 6.6% +/- 0.7%, 11.7% +/- 1.0%, and 16.4% +/- 1.3% in Gly389 subjects; P =.017) and systolic pressure (5.9% +/- 0.7%, 9.2% +/- 1.0%, and 11.6% +/- 1.2% in Arg389 subjects and 4.6% +/- 0.5%, 6.0% +/- 0.8%, and 9.9% +/- 0.9% in Gly389 subjects; P =.011). However, the difference in the fall in diastolic pressure was not statistically significant (P =.442). The Arg389 variant of the beta(1)-adrenergic receptor was associated with a greater response to metoprolol than that of Gly389 in young, male Chinese subjects. These data suggested that the beta(1)-adrenergic receptor Gly389Arg polymorphism is of major functional importance in vivo.
The effects of heart rate control in chronic heart failure with reduced ejection fraction.
Grande, Dario; Iacoviello, Massimo; Aspromonte, Nadia
2018-07-01
Elevated heart rate has been associated with worse prognosis both in the general population and in patients with heart failure. Heart rate is finely modulated by neurohormonal signals and it reflects the balance between the sympathetic and the parasympathetic limbs of the autonomic nervous system. For this reason, elevated heart rate in heart failure has been considered an epiphenomenon of the sympathetic hyperactivation during heart failure. However, experimental and clinical evidence suggests that high heart rate could have a direct pathogenetic role. Consequently, heart rate might act as a pathophysiological mediator of heart failure as well as a marker of adverse outcome. This hypothesis has been supported by the observation that the positive effect of beta-blockade could be linked to the degree of heart rate reduction. In addition, the selective heart rate control with ivabradine has recently been demonstrated to be beneficial in patients with heart failure and left ventricular systolic dysfunction. The objective of this review is to examine the pathophysiological implications of elevated heart rate in chronic heart failure and explore the mechanisms underlying the effects of pharmacological heart rate control.
Fetal heart rate and fetal heart rate variability in Lipizzaner broodmares.
Baska-Vincze, Boglárka; Baska, Ferenc; Szenci, Ottó
2015-03-01
Monitoring fetal heart rate (FHR) and fetal heart rate variability (FHRV) helps to understand and evaluate normal and pathological conditions in the foal. The aim of this study was to establish normal heart rate reference values for the ongoing equine pregnancy and to perform a heart rate variability (HRV) time-domain analysis in Lipizzaner mares. Seventeen middle- and late-term (days 121-333) pregnant Lipizzaner mares were examined using fetomaternal electrocardiography (ECG). The mean FHR (P = 0.004) and the standard deviation of FHR (P = 0.012) significantly decreased during the pregnancy. FHR ± SD values decreased from 115 ± 35 to 79 ± 9 bpm between months 5 and 11. Our data showed that HRV in the foal decreased as the pregnancy progressed, which is in contrast with the findings of earlier equine studies. The standard deviation of normal-normal intervals (SDNN) was higher (70 ± 25 to 166 ± 108 msec) than described previously. The root mean square of successive differences (RMSSD) decreased from 105 ± 69 to 77 ± 37 msec between the 5th and 11th month of gestation. Using telemetric ECG equipment, we could detect equine fetal heartbeat on day 121 for the first time. In addition, the large differences observed in the HR values of four mare-fetus pairs in four consecutive months support the assumption that there might be 'high-HR' and 'low-HR' fetuses in horses. It can be concluded that the analysis of FHR and FHRV is a promising tool for the assessment of fetal well-being but the applicability of these parameters in the clinical setting and in studs requires further investigation.
Isoda, Wakana C; Segal, Jack L
2003-02-01
To determine the effects of 4-aminopyridine (4-AP) on heart rate and PR, QT, and QTc intervals in patients with longstanding spinal cord injury (SCI). Randomized, active-treatment-controlled, dose level-blinded study, with allocation concealed. University-affiliated, tertiary care medical center. Sixty otherwise healthy male and female outpatients with traumatic SCI of more than 1 year's duration. Intervention. Oral administration and dose titration to tolerance of an immediate-release formulation of 4-AP. The PR interval, heart rate, QT interval, and QTc interval obtained from standard 12-lead electrocardiograms (ECGs) at baseline (before administration of 4-AP) and after 1 month of treatment were compared. The QTc intervals were derived by using Bazett's formula (equation) incorporated into standard computerized analyses of 12-lead ECG printouts. The paired t test was performed to test for the significance of differences between means and variances. No statistically significant differences were noted in heart rate or between ECG time intervals measured at baseline and after 1 month of treatment with 4-AP among all patients with SCI or between subgroups stratified by injury level (tetraplegia, paraplegia) or sex. During the 1-month period that 4-AP was administered, the heart rate and PR, QT, and QTc intervals all remained unchanged and stayed well within normal range in comparison to literature-derived control values. 4-Aminopyridine does not appear to influence the length of cardiac time intervals or heart rate and, hence, is unlikely to cause potentially life-threatening ventricular dysrrhythmias when administered long-term and taken orally in dosages of up to 30 mg/day. Specifically, cardiac repolarization (QTc interval) is unaffected in patients with SCI who continuously receive 4-AP for up to 1 month.
Park, Gewnhi; Moon, Eunok; Kim, Do-Won; Lee, Seung-Hwan
2012-12-01
A previous study has shown that greater cardiac vagal tone, reflecting effective self-regulatory capacity, was correlated with superior visual discrimination of fearful faces at high spatial frequency Park et al. (Biological Psychology 90:171-178, 2012b). The present study investigated whether individual differences in cardiac vagal tone (indexed by heart rate variability) were associated with different event-related brain potentials (ERPs) in response to fearful and neutral faces. Thirty-six healthy participants discriminated the emotion of fearful and neutral faces at broad, high, and low spatial frequencies, while ERPs were recorded. Participants with low resting heart rate variability-characterized by poor functioning of regulatory systems-exhibited significantly greater N200 activity in response to fearful faces at low spatial frequency and greater LPP responses to neutral faces at high spatial frequency. Source analyses-estimated by standardized low-resolution brain electromagnetic tomography (sLORETA)-tended to show that participants with low resting heart rate variability exhibited increased source activity in visual areas, such as the cuneus and the middle occipital gyrus, as compared with participants with high resting heart rate variability. The hyperactive neural activity associated with low cardiac vagal tone may account for hypervigilant response patterns and emotional dysregulation, which heightens the risk of developing physical and emotional problems.
Bae, Sanghyuk; Hong, Yun-Chul
2015-02-01
Bisphenol A (BPA) is a chemical used in plastic bottles and inner coating of beverage cans, and its exposure is almost ubiquitous. BPA has been associated with hypertension and decreased heart rate variability in the previous studies. The aim of the present study was to determine whether increased BPA exposure from consumption of canned beverage actually affects blood pressure and heart rate variability. We conducted a randomized crossover trial with noninstitutionalized adults, who were aged ≥60 years and recruited from a local community center. A total of 60 participants visited the study site 3 times, and they were provided the same beverage in 2 glass bottles, 2 cans, or 1 can and 1 glass bottle at a time. The sequence of the beverage was randomized. We then measured urinary BPA concentration, blood pressure, and heart rate variability 2 hours after the consumption of each beverage. The paired t test and mixed model were used to compare the differences. The urinary BPA concentration increased after consuming canned beverages by >1600% compared with that after consuming glass bottled beverages. Systolic blood pressure adjusted for daily variance increased by ≈4.5 mm Hg after consuming 2 canned beverages compared with that after consuming 2 glass bottled beverages, and the difference was statistically significant. The parameters of the heart rate variability did not show statistically significant differences.The present study demonstrated that consuming canned beverage and consequent increase of BPA exposure increase blood pressure acutely. © 2014 American Heart Association, Inc.
Wang, Yan; Cao, Li; Liang, Dong; Meng, Lulu; Wu, Yun; Qiao, Fengchang; Ji, Xiuqing; Luo, Chunyu; Zhang, Jingjing; Xu, Tianhui; Yu, Bin; Wang, Leilei; Wang, Ting; Pan, Qiong; Ma, Dingyuan; Hu, Ping; Xu, Zhengfeng
2018-02-01
Currently, chromosomal microarray analysis is considered the first-tier test in pediatric care and prenatal diagnosis. However, the diagnostic yield of chromosomal microarray analysis for prenatal diagnosis of congenital heart disease has not been evaluated based on a large cohort. Our aim was to evaluate the clinical utility of chromosomal microarray as the first-tier test for chromosomal abnormalities in fetuses with congenital heart disease. In this prospective study, 602 prenatal cases of congenital heart disease were investigated using single nucleotide polymorphism array over a 5-year period. Overall, pathogenic chromosomal abnormalities were identified in 125 (20.8%) of 602 prenatal cases of congenital heart disease, with 52.0% of them being numerical chromosomal abnormalities. The detection rates of likely pathogenic copy number variations and variants of uncertain significance were 1.3% and 6.0%, respectively. The detection rate of pathogenic chromosomal abnormalities in congenital heart disease plus additional structural anomalies (48.9% vs 14.3%, P < .0001) or intrauterine growth retardation group (50.0% vs 14.3%, P = .044) was significantly higher than that in isolated congenital heart disease group. Additionally, the detection rate in congenital heart disease with additional structural anomalies group was significantly higher than that in congenital heart disease with soft markers group (48.9% vs 19.8%, P < .0001). No significant difference was observed in the detection rates between congenital heart disease with additional structural anomalies and congenital heart disease with intrauterine growth retardation groups (48.9% vs 50.0%), congenital heart disease with soft markers and congenital heart disease with intrauterine growth retardation groups (19.8% vs 50.0%), or congenital heart disease with soft markers and isolated congenital heart disease groups (19.8% vs 14.3%). The detection rate in fetuses with congenital heart disease plus mild ventriculomegaly was significantly higher than in those with other types of soft markers (50.0% vs 15.6%, P < .05). Our study suggests chromosomal microarray analysis is a reliable and high-resolution technology and should be used as the first-tier test for prenatal diagnosis of congenital heart disease in clinical practice. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, III, Robert A. (Inventor)
1996-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, Robert A., III (Inventor)
1994-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate is presented. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
Heart Rate Complexity in Response to Upright Tilt in Persons with Down Syndrome
ERIC Educational Resources Information Center
Agiovlasitis, Stamatis; Baynard, Tracy; Pitetti, Kenneth H.; Fernhall, Bo
2011-01-01
People with Down syndrome (DS) show altered autonomic response to sympatho-excitation. Cardiac autonomic modulation may be examined with heart rate (HR) complexity which is associated uniquely with cardiovascular risk. This study examined whether the response of HR complexity to passive upright tilt differs between persons with and without DS and…
Sleep and wake phase of heart beat dynamics by artificial insymmetrised patterns
NASA Astrophysics Data System (ADS)
Dudkowska, A.; Makowiec, D.
2004-05-01
In order to determine differences between healthy patients and patients with congestive heart failure we apply the artificial insymmetrised pattern (AIP) method. The AIP method by exploring a human eye ability to extract regularities and read symmetries in a dot pattern, serves a tool for qualitative discrimination of heart rate states.
Gender-based differences in the cardiovascular response to standing
NASA Technical Reports Server (NTRS)
Gotshall, Robert W.; Tsai, Pai-Feng; Frey, Mary A. B.
1991-01-01
The cardiovascular responses of men and women to the stand test were compared by measuring respective values for heart rate, blood pressure, stroke volume, cardiac output, and total peripheral resistance during a 5-min supine and a 5-min standing test in ten subjects of each gender. It was found that, while the male and female subjects had similar heart rate values, all other responses exhibited greater changes in men than in women. While differences in the height of the subjects did not account for differences in cardiovascular responses, no mechanism responsible for these differences could be identified.
Cardiovascular responses to stress in Singapore and India.
Kaur, Divjyot; Bishop, George D
2013-02-01
Epidemiological studies have shown significant ethnic differences in coronary heart disease death rates with South Asians showing significantly greater coronary heart disease mortality than other groups. This research examined ethnic differences in cardiovascular reactivity (CVR) among Chinese, Malays and Indians in Singapore as well as a sample of Indians living in India. Experiment 1 examined differences across 303 Chinese, Malay and Indian undergraduates in Singapore, while Experiment 2 looked at differences in CVR between Indian participants from Singapore, and 145 Indians living in India. Systolic and diastolic blood pressure (SBP, DBP), heart rate (HR), cardiac index (CI) and total peripheral resistance index (TPRI) were measured during baselines and five laboratory tasks. Ethnicity main effects for SBP and CI reactivity were obtained in Experiment 1, with Indians showing significantly lower BP and CI reactivity than the Chinese and Malays. Significant main effects for sex were found with females showing lower reactivity than males for TPRI, and greater reactivity than males for HR and CI. Experiment 2 found that participants from India showed higher reactivity for SBP, HR and CI, while Indian participants from Singapore showed higher TPRI reactivity. These differences, however, often varied by task. These results point to differences in CVR among ethnic groups in Singapore as well as between Indians living in India and those living in Singapore. These differences may reflect cultural differences and need to be explored further with respect to their relationship to different rates of coronary heart disease among these groups. Copyright © 2012 Elsevier B.V. All rights reserved.
Wada, Koji; Eguchi, Hisashi; Prieto-Merino, David
2016-12-01
Occupation- and industry-based risks for stroke and ischemic heart disease may vary among Japanese working-aged men. We examined the differences in mortality rates between stroke and ischemic heart disease by occupation and industry among employed Japanese men aged 25-59 years. In 2010, we obtained occupation- and industry-specific vital statistics data from the Japanese Ministry of Health, Labour, and Welfare dataset. We analyzed data for Japanese men who were aged 25-59 years in 2010, grouped in 5-year age intervals. We estimated the mortality rates of stroke and ischemic heart disease in each age group for occupation and industry categories as defined in the national census. We did not have detailed individual-level variables. We used the number of employees in 2010 as the denominator and the number of events as the numerator, assuming a Poisson distribution. We conducted separate regression models to estimate the incident relative risk for stroke and ischemic heart disease for each category compared with the reference categories "sales" (occupation) and "wholesale and retail" (industry). When compared with the reference groups, we found that occupations and industries with a relatively higher risk of stroke and ischemic heart disease were: service, administrative and managerial, agriculture and fisheries, construction and mining, electricity and gas, transport, and professional and engineering. This suggests there are occupation- and industry-based mortality risk differences of stroke and ischemic heart disease for Japanese working-aged men. These differences in risk might be explained to factors associated with specific occupations or industries, such as lifestyles or work styles, which should be explored in further research. The mortality risk differences of stroke and ischemic heart disease shown in the present study may reflect an excessive risk of Karoshi (death from overwork).
Murphy, Jennifer; Millgate, Edward; Geary, Hayley; Ichijo, Eri; Coll, Michel-Pierre; Brewer, Rebecca; Catmur, Caroline; Bird, Geoffrey
2018-03-01
Evidence suggests that intelligence is positively associated with performance on the heartbeat counting task (HCT). The HCT is often employed as measure of interoception - the ability to perceive the internal state of one's body - however it's use remains controversial as performance on the HCT is strongly influenced by knowledge of resting heart rate. This raises the possibility that heart rate knowledge may mediate the previously-observed association between intelligence and HCT performance. Study One demonstrates an association between intelligence and HCT performance (N = 94), and Study Two demonstrates that this relationship is mediated by knowledge of the average resting heart rate (N = 134). These data underscore the need to account for the influence of prior knowledge and beliefs when examining individual differences in cardiac interoceptive accuracy using the HCT. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.
Finch, M B; O'Connor, P C; Harron, D W; Shanks, R G
1983-01-01
1 The present study compared the effects in healthy volunteers of the acute and chronic administration of placebo, pindolol and propranolol to see if the partial agonist activity of pindolol was reduced by the beta-adrenoceptor blocking activity of pindolol on chronic administration. 2 Five subjects received in random order for 8 days placebo, propranolol 160 mg and pindolol 10 mg; on days 1 and 8 treatments were given twice at 0 and 2 h. Heart rate in supine position and at end of exercise was recorded before dosing and at 2 and 4 h post-dosing on days 1 and 8. 3 Propranolol and pindolol reduced exercise heart rate to the same extent on days 1 and 8. 4 Propranolol reduced supine heart rate more than pindolol on days 1 and 8 but the difference was only significant on day 8. PMID:6849778
Carnevali, Luca; Trombini, Mimosa; Graiani, Gallia; Madeddu, Denise; Quaini, Federico; Landgraf, Rainer; Neumann, Inga D; Nalivaiko, Eugene; Sgoifo, Andrea
2014-04-10
In humans, there is a documented association between anxiety disorders and cardiovascular disease. Putative underlying mechanisms may include an impairment of the autonomic nervous system control of cardiac function. The primary objective of the present study was to characterize cardiac autonomic modulation and susceptibility to arrhythmias in genetic lines of rats that differ largely in their anxiety level. To reach this goal, electrocardiographic recordings were performed in high-anxiety behavior (HAB, n=10) and low-anxiety behavior (LAB, n=10) rats at rest, during stressful stimuli and under autonomic pharmacological manipulations, and analyzed by means of time- and frequency-domain indexes of heart rate variability. During resting conditions, HAB rats displayed a reduced heart rate variability, mostly in terms of lower parasympathetic (vagal) modulation compared to LAB rats. In HAB rats, this relatively low cardiac vagal control was associated with smaller heart rate responsiveness to acute stressors compared to LAB counterparts. In addition, beta-adrenergic pharmacological stimulation induced a larger incidence of ventricular tachyarrhythmias in HABs compared to LABs. At sacrifice, a moderate increase in heart-body weight ratio was observed in HAB rats. We conclude that high levels of anxiety-related behavior in rats are associated with signs of i) impaired autonomic modulation of heart rate (low vagally-mediated heart rate variability), ii) poor adaptive heart rate responsiveness to stressful stimuli, iii) increased arrhythmia susceptibility, and iv) cardiac hypertrophy. These results highlight the utility of the HAB/LAB model for investigating the mechanistic basis of the comorbidity between anxiety disorders and cardiovascular disease. Copyright © 2014 Elsevier Inc. All rights reserved.
Heart rate and suicide: findings from two cohorts of 533 000 Taiwanese and 75 000 Norwegian adults.
Chang, S-S; Bjørngaard, J H; Tsai, M K; Bjerkeset, O; Wen, C P; Yip, P S F; Tsao, C K; Gunnell, D
2016-04-01
To investigate the association of resting heart rate with suicide in two large cohorts. The MJ cohort (Taiwan) included 532 932 adults from a health check-up programme (1994-2008). The HUNT cohort (Norway) included 74 977 adults in the Nord-Trøndelag County study (1984-1986), followed up to 2004. In both cohorts heart rate was measured at baseline, and suicide was ascertained through linkage to cause-of-death registers. Risk of suicide was estimated using Cox proportional hazards models. There were 569 and 188 suicides (average follow-up period of 8.1 and 16.9 years) in the MJ and HUNT cohorts respectively. Sex- and age-adjusted hazard ratio for every 10 beat increase in heart rate per minute was 1.08 (95% Confidence Interval 1.00-1.16) and 1.24 (1.12-1.38) in the MJ and HUNT cohorts, respectively. In the MJ cohort this association was confined to individuals with a history of heart diseases vs. those without such a history (P for interaction = 0.008). In the HUNT cohort the association did not differ by history of heart diseases and was robust to adjustment for health-related life style, medication use, and symptoms of anxiety and depression. Elevated resting heart rate may be a marker of increased suicide risk. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Adhikari, Richa; D’Souza, Jennifer; Solimon, Elsayed Z.; Burke, Gregory L.; Daviglus, Martha; Jacobs, David R.; Park, Sung Kyun; Sheppard, Lianne; Thorne, Peter S.; Kaufman, Joel D.; Larson, Timothy V.; Adar, Sara D.
2017-01-01
Background Reduced heart rate variability, a marker of impaired cardiac autonomic function, has been linked to short-term exposure to airborne particles. This research adds to the literature by examining associations with long-term exposures to coarse particles (PM10-2.5). Methods Using electrocardiogram recordings from 2,780 participants (45-84 years) from three Multi-Ethnic Study of Atherosclerosis sites, we assessed the standard deviation of normal-to-normal intervals (SDNN) and root-mean square differences of successive normal-to-normal intervals (rMSSD) at a baseline (2000-2002) and follow-up (2010-2012) examination (mean visits/person=1.5). Annual average concentrations of PM10-2.5 mass, copper, zinc, phosphorus, silicon, and endotoxin were estimated using site-specific spatial prediction models. We assessed associations for baseline heart rate variability and rate of change in heart rate variability over time using multivariable mixed models adjusted for time, sociodemographic, lifestyle, health, and neighborhood confounders, including co-pollutants. Results In our primary models adjusted for demographic and lifestyle factors and site, PM10-2.5 mass was associated with 1.0% (95% CI: -4.1, 2.1%) lower SDNN levels per interquartile range of 2 μg/m3. Stronger associations, however, were observed prior to site adjustment and with increasing residential stablity. Similar patterns were found for rMSSD. We found little evidence for associations with other chemical species and with with the rate of change in heart rate variability, though endotoxin was associated with increasing heart rate variability over time. Conclusion We found only weak evidence that long-term PM10-2.5 exposures are associated with lowered heart rate variability. Stronger associations among residentially stable individuals suggest that confirmatory studies are needed. PMID:27035690
Ukena, Christian; Mahfoud, Felix; Kindermann, Ingrid; Barth, Christine; Lenski, Matthias; Kindermann, Michael; Brandt, Mathias C; Hoppe, Uta C; Krum, Henry; Esler, Murray; Sobotka, Paul A; Böhm, Michael
2011-09-06
This study sought to investigate the effects of interventional renal sympathetic denervation (RD) on cardiorespiratory response to exercise. RD reduces blood pressure at rest in patients with resistant hypertension. We enrolled 46 patients with therapy-resistant hypertension as extended investigation of the Symplicity HTN-2 (Renal Denervation With Uncontrolled Hypertension) trial. Thirty-seven patients underwent bilateral RD and 9 patients were assigned to the control group. Cardiopulmonary exercise tests were performed at baseline and 3-month follow-up. In the RD group, compared with baseline examination, blood pressure at rest and at maximum exercise after 3 months was significantly reduced by 31 ± 13/9 ± 13 mm Hg (p < 0.0001) and by 21 ± 20/5 ± 14 mm Hg (p < 0.0001), respectively. Achieved work rate increased by 5 ± 13 W (p = 0.029) whereas peak oxygen uptake remained unchanged. Blood pressure 2 min after exercise was significantly reduced by 29 ± 17/8 ± 15 mm Hg (p < 0.001 for systolic blood pressure; p = 0.002 for diastolic blood pressure). Heart rate at rest decreased after RD (4 ± 11 beats/min; p = 0.028), whereas maximum heart rate and heart rate increase during exercise were not different. Heart rate recovery improved significantly by 4 ± 7 beats/min after renal denervation (p = 0.009). In the control group, there were no significant changes in blood pressure, heart rate, maximum work rate, or ventilatory parameters after 3 months. RD reduces blood pressure during exercise without compromising chronotropic competence in patients with resistant hypertension. Heart rate at rest decreased and heart rate recovery improved after the procedure. (Renal Denervation With Uncontrolled Hypertension; [Symplicity HTN-2]; NCT00888433). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Assessing Heart Rate in Physical Education. Assessment Series: K-12 Physical Education.
ERIC Educational Resources Information Center
Buck, Marilyn M.
This guide discusses the assessment of heart rate and, in particular, the assessment of heart rate using a heart monitor. Part 1, "Foundation for the Use of Heart Rate," reviews literature about heart rate assessment and heart rate monitors, offering an overview of national guidelines for physical activity. It focuses on the importance…
Evaluation and management of bradycardia in neonates and children.
Baruteau, Alban-Elouen; Perry, James C; Sanatani, Shubhayan; Horie, Minoru; Dubin, Anne M
2016-02-01
Heart rate is commonly used in pediatric early warning scores. Age-related changes in the anatomy and physiology of infants and children produce normal ranges for electrocardiogram features that differ from adults and vary with age. Bradycardia is defined as a heart rate below the lowest normal value for age. Pediatric bradycardia most commonly manifests as sinus bradycardia, junctional bradycardia, or atrioventricular block. As a result of several different etiologies, it may occur in an entirely structurally normal heart or in association with concomitant congenital heart disease. Genetic variants in multiple genes have been described to date in the pathogenesis of inherited sinus node dysfunction or progressive cardiac conduction disorders. Management and eventual prognosis of bradycardia in the young are entirely dependent upon the underlying cause. Reasons to intervene for bradycardia are the association of related symptoms and/or the downstream risk of heart failure or pause-dependent tachyarrhythmia. The simplest aspect of severe bradycardia management is reflected in the Pediatric and Advanced Life Support (PALS) guidelines. Early diagnosis and appropriate management are critical in many cases in order to prevent sudden death, and this review critically assesses our current practice for evaluation and management of bradycardia in neonates and children. Bradycardia is defined as a heart rate below the lowest normal value for age. Age related changes in the anatomy and physiology of infants and children produce normal ranges for electrocardiogram features that differ from adults and vary with age. Pediatric bradycardia most commonly manifests as sinus bradycardia, junctional bradycardia, or atrioventricular block. Management and eventual prognosis of bradycardia in the young are entirely dependent upon the underlying cause. Bradycardia may occur in a structurally normal heart or in association with congenital heart disease. Genetic variants in multiple genes have been described. Reasons to intervene for bradycardia are the association of related symptoms and/or the downstream risk of heart failure or pause-dependent tachyarrhythmia. Early diagnosis and appropriate management are critical in order to prevent sudden death.
Heart rate variability is associated with social value orientation in males but not females.
Lischke, Alexander; Mau-Moeller, Anett; Jacksteit, Robert; Pahnke, Rike; Hamm, Alfons O; Weippert, Matthias
2018-05-09
Phylogenetic and neurobiological theories suggest that inter-individual differences in high frequency heart rate variability (HF-HRV) are associated with inter-individual differences in social behavior and social cognition. To test these theories, we investigated whether individuals with high and low HF-HRV would show different preferences for cooperative behavior in social contexts. We recorded resting state HF-HRV in 84 healthy individuals before they completed the Social Value Orientation task, a well-established measure of cooperative preferences. HF-HRV was derived from short-term (300 s) and ultra-short-term (60 s, 120 s) recordings of participants' heart rate to determine the robustness of possible findings. Irrespective of recording length, we found a sex-dependent association between inter-individual differences in HF-HRV and inter-individual differences in social value orientation: The preference for cooperation was more pronounced among individuals with high as compared low HF-HRV, albeit only in male and not in female participants. These findings suggest that males with high HF-HRV are more inclined to engage in cooperative behavior than males with low HF-HRV.
Prevalence of obesity among patients with congenital and acquired heart disease.
Shustak, Rachel J; McGuire, Sharda B; October, Tessie W; Phoon, Colin K L; Chun, Anne J L
2012-01-01
Overweight and obesity rates have risen dramatically in the United States, with subsequent detrimental comorbidity risks. The rates for obesity among children with congenital and acquired heart disease have rarely been reported. A retrospective cross-sectional study was conducted to determine the prevalence of overweight and obesity in children with heart disease and to identify subgroups at increased risk. A total of 795 cases were identified from a chart review of patients presenting to an urban center's Pediatric Cardiology Program between 1 January and 31 December 2006. A body mass index (BMI) at the 85th percentile or higher was defined as overweight, and a BMI at the 95th percentile or higher was defined as obese. Subjects with comorbidities affecting body habitus were excluded from the study. Overall, overweight and obesity rates were similar to national data. No significant differences in overweight or obesity rates were detected between heart disease and non-heart disease groups (P = 0.50). According to multivariate analysis, Hispanic ethnicity and male gender were the only predictors of obesity. This study shows that children with heart disease are not immune to the common predictors of obesity such as gender and ethnicity and that the future care of children with heart disease should include general discussions about the risks for obesity.
PREDICE score as a predictor of 90 days mortality in patients with heart failure
NASA Astrophysics Data System (ADS)
Purba, D. P. S.; Hasan, R.
2018-03-01
Hospitalization in chronic heart failure patients associated with high mortality and morbidity rate. The 90 days post-discharge period following hospitalization in heart failure patients is known as the vulnerable phase, it carries the high risk of poor outcomes. Identification of high-risk individuals by using prognostic evaluation was intended to do a closer follow up and more intensive to decreasing the morbidity and mortality rate of heart failure.To determine whether PREDICE score could predict mortality within 90 days in patients with heart failure, an observational cohort study in patients with heart failure who were hospitalized due to worsening chronic heart failure. Patients were in following-up for up to 90 days after initial evaluation with the primary endpoint is death.We found a difference of the significantstatistical between PREDICE score in survival and mortality group (p=0.001) of 84% (95% CI: 60.9% - 97.4%).In conclusion, PREDICE score has a good ability to predict mortality within 90 days in patients with heart failure.
Evaluation of heart rate variability indices using a real-time handheld remote ECG monitor.
Singh, Swaroop S; Carlson, Barbara W; Hsiao, Henry S
2007-12-01
Studies on retrospective electrocardiogram (ECG) recordings of patients during cardiac arrest have shown significant changes in heart rate variability (HRV) indices prior to the onset of cardiac arrhythmia. The early detection of these changes in HRV indices increases the chances for a successful medical intervention by increasing the response time window. A portable, handheld remote ECG monitor designed in this research detects the QRS complex and calculates short-term HRV indices in real-time. The QRS detection of the ECG recordings of subjects from the MIT-Arrhythmia database yielded a mean sensitivity of 99.34% and a specificity of 99.31%. ECG recordings from normal subjects and subjects with congestive heart failure were used to identify the differences in HRV indices. An increase in heart rate, high-frequency spectral power (HFP), total spectral power, the ratio of HFP to low-frequency spectral power (LFP), and a decrease in root mean square sum of RR differences were observed. No difference was found on comparison of the standard deviation of normal to normal interval between adjacent R-waves, LFP, and very-low-frequency spectral power. Based on these, additional analytical calculations could be made to provide early warnings of impending cardiac conditions.
Web-Based Mindfulness Intervention in Heart Disease: A Randomized Controlled Trial
Younge, John O.; Wery, Machteld F.; Gotink, Rinske A.; Utens, Elisabeth M. W. J.; Michels, Michelle; Rizopoulos, Dimitris; van Rossum, Elisabeth F. C.
2015-01-01
Background Evidence is accumulating that mindfulness training has favorable effects on psychological outcomes, but studies on physiological outcomes are limited. Patients with heart disease have a high incidence of physiological and psychological problems and may benefit from mindfulness training. Our aim was to determine the beneficial physiological and psychological effects of online mindfulness training in patients with heart disease. Methods The study was a pragmatic randomized controlled single-blind trial. Between June 2012 and April 2014 we randomized 324 patients (mean age 43.2 years, 53.7% male) with heart disease in a 2:1 ratio (n = 215 versus n = 109) to a 12-week online mindfulness training in addition to usual care (UC) compared to UC alone. The primary outcome was exercise capacity measured with the 6 minute walk test (6MWT). Secondary outcomes were other physiological parameters (heart rate, blood pressure, respiratory rate, and NT-proBNP), subjective health status (SF-36), perceived stress (PSS), psychological well-being (HADS), social support (PSSS12) and a composite endpoint (all-cause mortality, heart failure, symptomatic arrhythmia, cardiac surgery, and percutaneous cardiac intervention). Linear mixed models were used to evaluate differences between groups on the repeated outcome measures. Results Compared to UC, mindfulness showed a borderline significant improved 6MWT (effect size, meters: 13.2, 95%CI: -0.02; 26.4, p = 0.050). There was also a significant lower heart rate in favor of the mindfulness group (effect size, beats per minute: -2.8, 95%CI: -5.4;-0.2, p = 0.033). No significant differences were seen on other outcomes. Conclusions Mindfulness training showed positive effects on the physiological parameters exercise capacity and heart rate and it might therefore be a useful adjunct to current clinical therapy in patients with heart disease. Trial Registration Dutch Trial Register 3453 PMID:26641099
Gender differences in patients with heart failure.
Strömberg, Anna; Mårtensson, Jan
2003-04-01
The aim of this literature review was to review and discuss the differences between men and women with heart failure with regard to epidemiology, aetiology, diagnostics, prognosis, pharmacological and non-pharmacological treatment, and the impact of heart failure on psychosocial factors and healthcare utilisation. Two primary health care resources, MEDLINE and CINAHL, were selected to review the current literature. In MEDLINE, 234 abstracts dealing with heart failure and gender/sex were found and in CINAHL, 20 abstracts. Men have a higher incidence of heart failure, but the overall prevalence rate is similar in both sexes, since women survive longer after the onset of heart failure. Women tend to be older when diagnosed with heart failure and more often have diastolic dysfunction than men. The extent of sex differences in treatment, hospital cost and quality of care can partly be explained by age differences. The life situations for men and women with heart failure are different. Physical and social restrictions affecting daily life activities are experienced as most bothersome for men, whereas restrictions affecting the possibility to support family and friends are most difficult to accept for women. Women with heart failure ascribe more positive meanings to their illness. Despite this, women seem to experience a lower overall quality of life than men. The known gender differences in patients with heart failure need to be highlighted in guidelines as well as implemented in standard care.
Mozina, Hugo; Podbregar, Matej
2010-01-01
Discrepancies of 5-24% between superior vena cava oxygen saturation (ScvO2) and mixed venous oxygen saturation (SvO2) have been reported in patients with severe heart failure. Thenar muscle tissue oxygenation (StO2) measured with near-infrared spectroscopy (NIRS) during arterial occlusion testing decreases slower in sepsis/septic shock patients (lower StO2 deoxygenation rate). The StO2 deoxygenation rate is influenced by dobutamine. The aim of this study was to determine the relationship between the StO2 deoxygenation rate and the ScvO2-SvO2 discrepancy in patients with severe left heart failure and additional sepsis/septic shock treated with or without dobutamine. Fifty-two patients with severe left heart failure due to primary heart disease with additional severe sepsis/septic shock were included. SvO2 and ScvO2 were compared to the thenar muscle StO2 before and during arterial occlusion. SvO2 correlated significantly with ScvO2 (Pearson correlation 0.659, P = 0.001), however, Bland Altman analysis showed a clinically important difference between both variables (ScvO2-SvO2 mean 72 +/- 8%, ScvO2-SvO2 difference 9.4 +/- 7.5%). The ScvO2-SvO2 difference correlated with plasma lactate (Pearson correlation 0.400, P = 0.003) and the StO2 deoxygenation rate (Pearson correlation 0.651, P = 0.001). In the group of patients treated with dobutamine, the ScvO2-SvO2 difference correlated with plasma lactate (Pearson correlation 0.389, P = 0.011) and the StO2 deoxygenation rate (Pearson correlation 0.777, P = 0.0001). In patients with severe heart failure with additional severe sepsis/septic shock the ScvO2-SvO2 discrepancy presents a clinical problem. In these patients the skeletal muscle StO2 deoxygenation rate is inversely proportional to the difference between ScvO2 and SvO2; dobutamine does not influence this relationship. When using ScvO2 as a treatment goal, the NIRS measurement may prove to be a useful non-invasive diagnostic test to uncover patients with a normal ScvO2 but potentially an abnormally low SvO2. NCT00384644 ClinicalTrials.Gov.
Effect of training mode on post-exercise heart rate recovery of trained cyclists.
McDonald, Kelia G; Grote, Silvie; Shoepe, Todd C
2014-06-28
The sympathetic nervous system dominates the regulation of body functions during exercise. Therefore after exercise, the sympathetic nervous system withdraws and the parasympathetic nervous system helps the body return to a resting state. In the examination of this relationship, the purpose of this study was to compare recovery heart rates (HR) of anaerobically versus aerobically trained cyclists. With all values given as means ± SD, anaerobically trained track cyclists (n=10, age=25.9 ± 6.0 yrs, body mass=82.7 ± 7.1 kg, body fat=10.0 ± 6.3%) and aerobically trained road cyclists (n=15, age=39.9 ± 8.5 yrs, body mass=75.3 ± 9.9 kg, body fat=13.1 ± 4.5%) underwent a maximal oxygen uptake test. Heart rate recovery was examined on a relative basis using heart rate reserve as well as the absolute difference between maximum HR and each of two recovery HRs. The post-exercise change in HR at minute one for the track cyclists and road cyclists respectively were 22 ± 8 bpm and 25 ± 12 bpm. At minute two, the mean drop for track cyclists was significantly (p<0.05) greater than the road cyclists (52 ± 15 bpm and 64 ± 11 bpm). Training mode showed statistically significant effects on the speed of heart rate recovery in trained cyclists. Greater variability in recovery heart rate at minute two versus minute one suggests that the heart rate should be monitored longer than one minute of recovery for a better analysis of post-exercise autonomic shift.
Al Rasheed, N M; Al Sayed, M I; Al Zuhair, H H; Al Obaid, A R; Fatani, A J
2001-04-01
Two new analogues of lidocaine were synthesized at the College of Pharmacy, King Saud University: compound I (Methyl-2-[2-(N,N-diethylamino) acetamido]-3-cyano-4,5-dimethylbenzoate) and compound II (Methyl-2-[2-(piperidino) acetamido]-3-cyano-4,5-dimethylbenzoate). Their influence on the arterial blood pressure and the heart rate of urethane-anaesthetized rats was studied and compared with the actions of lidocaine. Compounds I, II and lidocaine induced significant dose-dependent decreases in the arterial blood pressure and heart rate, which usually returned to basal values within 3-5 min. There were significant differences in the potency of the three compounds in producing their effects on blood pressure and heart rate (P< 0.0001, ANOVA). Compound II was 14 and 6 times more potent in reducing blood pressure and 8 and 2 times more capable of reducing the heart rate than lidocaine and compound I, respectively. The results of this study also indicated the ineffectiveness of antagonists of autonomic, histaminergic and 5-HT receptor, and various vasodilators in blocking the actions of the three compounds on blood pressure and heart rate. Pretreatment with CaCl(2)significantly reduced the hypotension and bradycardia induced by the three compounds, suggesting the involvement of calcium channels, probably of the L type. Several possible mechanisms are postulated. In conclusion, the results direct attention to the capability of the two new compounds to decrease blood pressure and heart rate; affects that may have clinical potential. Copyright 2001 Academic Press.
Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J; Wintersperger, Bernd J; Li, Qin; Forero, Julian; Paul, Narinder S; Nguyen, Elsie T
2016-10-01
To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. • Relaxation music does not reduce heart rate in cardiac CT • Relaxation music does not reduce beta-blocker use in cardiac CT • Relaxation music has no effect on cardiac CT image quality • Low levels of anxiety are present in patients prior to cardiac CT • Patients enjoyed the relaxation music and this results in improved patient experience.
Randomised controlled trial of intrapartum fetal heart rate monitoring.
Mahomed, K; Nyoni, R; Mulambo, T; Kasule, J; Jacobus, E
1994-02-19
To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. Prospective randomised controlled trial. Referral maternity hospital, Harare, Zimbabwe. 1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources.
Randomised controlled trial of intrapartum fetal heart rate monitoring.
Mahomed, K.; Nyoni, R.; Mulambo, T.; Kasule, J.; Jacobus, E.
1994-01-01
OBJECTIVE--To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. DESIGN--Prospective randomised controlled trial. SETTING--Referral maternity hospital, Harare, Zimbabwe. SUBJECTS--1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. INTERVENTIONS--Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. MAIN OUTCOME MEASURES--Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. RESULTS--Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. CONCLUSIONS--Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources. PMID:8136665
Mendonca, Goncalo V; Teixeira, Micael S; Heffernan, Kevin S; Fernhall, Bo
2013-06-01
Ingestion of water attenuates the chronotropic response to submaximal exercise. However, it is not known whether this effect is equally manifested during dynamic exercise below and above the ventilatory threshold (VT). We explored the effects of water ingestion on the heart rate response to an incremental cycle-ergometer protocol. In a randomized fashion, 19 healthy adults (10 men and nine women, age 20.9 ± 1.8 years) ingested 50 and 500 ml of water before completing a cycle-ergometer protocol on two separate days. The heart rate and oxygen uptake ( ) responses to water ingestion were analysed both at rest and during exercise performed below and above the VT. The effects of water intake on brachial blood pressure were measured only at rest. Resting mean arterial pressure increased and resting heart rate decreased, but only after 500 ml of water (P < 0.05). Compared with that seen after 50 ml of water, the 500 ml volume elicited an overall decrease in submaximal heart rate (P < 0.05). In contrast, drinking 500 ml of water did not affect submaximal . The participants' maximal heart rate, maximal and VT were similar between conditions. Our results therefore indicate that, owing to its effects on submaximal heart rate over a broad spectrum of intensities, the drinking of water should be recognized as a potential confounder in cardiovascular exercise studies. However, by showing no differences between conditions for submaximal , they also suggest that the magnitude of heart rate reduction after drinking 500 ml of water may be of minimal physiological significance for exercise cardiorespiratory capacity.
Chanchai, Rattanachai; Kanjanavanit, Rungsrit; Leemasawat, Krit; Amarittakomol, Anong; Topaiboon, Paleerat; Phrommintikul, Arintaya
2018-01-01
Background: Beta-blockers have been shown to decrease mortality and morbidity in heart failure with reduced ejection fraction (HFrEF) patients. However, the side effects are also dose-related, leading to the underdosing. Cost constraint may be one of the limitations of appropriate beta-blocker use; this can be improved with generic drugs. However, the effects in real life practice have not been investigated. Methods and results: This study aimed to compare the efficacy and safety of generic and brand beta-blockers in HFrEF patients. We performed a retrospective cohort analysis in HFrEF patients who received either generic or brand beta-blocker in Chiang Mai Heart Failure Clinic. The primary endpoint was the proportion of patients who received at least 50% target dose of beta-blocker between generic and brand beta-blockers. Adverse events were secondary endpoints. 217 patients (119 and 98 patients received generic and brand beta-blocker, respectively) were enrolled. There were no differences between groups regarding age, gender, etiology of heart failure, New York Heart Association (NYHA) functional class, left ventricular ejection fraction (LVEF), rate of receiving angiotensin converting enzyme inhibitor (ACEI), angiotensin recepter blocker (ARB), or spironolactone. Patients receiving brand beta-blockers had lower resting heart rate at baseline (74.9 and 84.2 bpm, p = .001). Rate of achieved 50% target dose and target daily dose did not differ between groups (40.4 versus 44.5% and 48.0 versus 55.0%, p > .05, respectively). Rate of side effects was not different between groups (32.3 versus 29.5%, p > .05) and the most common side effect was hypotension. Conclusion: This study demonstrated that beta-blocker tolerability was comparable between brand and generic formulations. Generic or brand beta-blockers should be prescribed to HFrEF patients who have no contraindications.
Chanchai, Rattanachai; Kanjanavanit, Rungsrit; Leemasawat, Krit; Amarittakomol, Anong; Topaiboon, Paleerat; Phrommintikul, Arintaya
2018-01-01
Abstract Background: Beta-blockers have been shown to decrease mortality and morbidity in heart failure with reduced ejection fraction (HFrEF) patients. However, the side effects are also dose-related, leading to the underdosing. Cost constraint may be one of the limitations of appropriate beta-blocker use; this can be improved with generic drugs. However, the effects in real life practice have not been investigated. Methods and results: This study aimed to compare the efficacy and safety of generic and brand beta-blockers in HFrEF patients. We performed a retrospective cohort analysis in HFrEF patients who received either generic or brand beta-blocker in Chiang Mai Heart Failure Clinic. The primary endpoint was the proportion of patients who received at least 50% target dose of beta-blocker between generic and brand beta-blockers. Adverse events were secondary endpoints. 217 patients (119 and 98 patients received generic and brand beta-blocker, respectively) were enrolled. There were no differences between groups regarding age, gender, etiology of heart failure, New York Heart Association (NYHA) functional class, left ventricular ejection fraction (LVEF), rate of receiving angiotensin converting enzyme inhibitor (ACEI), angiotensin recepter blocker (ARB), or spironolactone. Patients receiving brand beta-blockers had lower resting heart rate at baseline (74.9 and 84.2 bpm, p = .001). Rate of achieved 50% target dose and target daily dose did not differ between groups (40.4 versus 44.5% and 48.0 versus 55.0%, p > .05, respectively). Rate of side effects was not different between groups (32.3 versus 29.5%, p > .05) and the most common side effect was hypotension. Conclusion: This study demonstrated that beta-blocker tolerability was comparable between brand and generic formulations. Generic or brand beta-blockers should be prescribed to HFrEF patients who have no contraindications. PMID:29379674
Bounded Kalman filter method for motion-robust, non-contact heart rate estimation
Prakash, Sakthi Kumar Arul; Tucker, Conrad S.
2018-01-01
The authors of this work present a real-time measurement of heart rate across different lighting conditions and motion categories. This is an advancement over existing remote Photo Plethysmography (rPPG) methods that require a static, controlled environment for heart rate detection, making them impractical for real-world scenarios wherein a patient may be in motion, or remotely connected to a healthcare provider through telehealth technologies. The algorithm aims to minimize motion artifacts such as blurring and noise due to head movements (uniform, random) by employing i) a blur identification and denoising algorithm for each frame and ii) a bounded Kalman filter technique for motion estimation and feature tracking. A case study is presented that demonstrates the feasibility of the algorithm in non-contact estimation of the pulse rate of subjects performing everyday head and body movements. The method in this paper outperforms state of the art rPPG methods in heart rate detection, as revealed by the benchmarked results. PMID:29552419
Ojeda, Soledad; Anguita, Manuel; Muñoz, Juan F; Rodríguez, Marcos T; Mesa, Dolores; Franco, Manuel; Ureña, Isabel; Vallés, Federico
2003-11-01
To assess the prevalence, clinical profile and medium-term prognosis in patients with heart failure and preserved systolic ventricular function compared to those with systolic dysfunction. 153 patients were included, 62 with preserved systolic ventricular function (left ventricular ejection fraction > or = 45%) and 91 with impaired systolic ventricular function (left ventricular ejection fraction < 45%). The mean follow-up period was 25 10 months. Mean age was similar (66 10 vs. 65 10; p = 0.54). There was a higher proportion of women among patients with preserved systolic function (53% vs. 28%; p < 0.01). Ischemic and idiopathic cardiomyopathy were the most common causes of heart failure in patients with systolic dysfunction, whereas valvular disease and hypertensive cardiopathy were the most common in patients with preserved systolic function. Angiotensin-converting enzyme inhibitors and beta-blockers were more often prescribed in patients with impaired systolic ventricular function (86% vs. 52%; p < 0.01 and 33% vs. 11%; p < 0.01, respectively). There were no differences between the groups in terms of mortality rate (37% vs. 29%), readmission rate for other causes (29% vs. 23%), readmission rate for heart failure (45% vs. 45%), cumulative survival (51% vs. 62%) and the likelihood of not being readmitted for heart failure (50% vs. 52%). In the multivariate analysis, left ventricular ejection fraction was not a predictor of death or readmission because of heart failure. In a large proportion of patients with heart failure, systolic ventricular function is preserved. Despite the clinical differences between patients with preserved and impaired systolic ventricular function, the medium-term prognosis was similar in both groups.
Frequency-dependent baroreflex control of blood pressure and heart rate during physical exercise.
Spadacini, Giammario; Passino, Claudio; Leuzzi, Stefano; Valle, Felice; Piepoli, Massimo; Calciati, Alessandro; Sleight, Peter; Bernardi, Luciano
2006-02-15
It is widely recognised that during exercise vagal heart rate control is markedly impaired but blood pressure control may or may not be retained. We hypothesised that this uncertainty arose from the differing responses of the vagus (fast) and sympathetic (slow) arms of the autonomic effectors, and to differing sympatho-vagal balance at different exercise intensities. We studied 12 normals at rest, during moderate (50% maximal heart rate) and submaximal (80% maximal heart rate) exercise. The carotid baroreceptors were stimulated by sinusoidal neck suction at the frequency of the spontaneous high- (during moderate exercise) and low-frequency (during submaximal) fluctuations in heart period and blood pressure. The increases in these oscillations induced by neck suction were measured by autoregressive spectral analysis. At rest neck stimulation increased variability at low frequency (RR: from 6.99+/-0.24 to 8.87+/-0.18 ln-ms2; systolic pressure: from 3.05+/-1.7 to 4.09+/-0.17 ln-mm Hg2) and high frequency (RR: from 4.67+/-0.25 to 6.79+/-0.31 ln-ms2; systolic pressure: from 1.93+/-0.2 to 2.67+/-0.125 ln-mm Hg2) (all p<0.001). During submaximal exercise RR variability decreased but systolic pressure variability rose (p<0.01 vs rest); during submaximal exercise low-frequency neck stimulation increased the low-frequency fluctuations in blood pressure (2.35+/-0.51 to 4.25+/-0.38 ln-mm Hg2, p<0.05) and RR. Conversely, neck suction at high frequency was ineffective on systolic pressure, and had only minor effects on RR interval during moderate exercise. During exercise baroreflex control is active on blood pressure, but the efferent response on blood pressure and heart rate is only detected during low frequency stimulation, indicating a frequency-dependent effect.
Soncini, Emanuele; Paganelli, Simone; Vezzani, Cristina; Gargano, Giancarlo; Giovanni Battista, La Sala
2014-09-01
To assess the ability of the intrapartum fetal heart rate interpretation system developed in 2008 by the National Institute of Child Health and Human Development (NICHD) to predict fetal metabolic acidosis at delivery and neonatal neurological morbidity. We analyzed the intrapartum fetal heart rate tracings of 314 singleton fetuses at ≥ 37 weeks using the NICHD three-tier system of interpretation: Category I (normal), Category II (indeterminate) and Category III (abnormal). Category II was further divided into Category IIA, with moderate fetal heart rate variability or accelerations, and Category IIB, with minimal/absent fetal heart rate variability and no accelerations. The presence and duration of the different patterns were compared with several clinical neonatal outcomes and with umbilical artery acid-base balance at birth. The mean values of pH and base excess decreased proportionally as tracings worsened (p < 0.001). The duration of at least 30 min for Category III tracings was highly predictive of a pH <7.00 and a base excess ≤-12 mmol/L. The same was true for the duration of Category IIB tracings that lasted for at least 50 min. Our study demonstrates that the interpretation of fetal heart rate tracings based on a strictly standardized system is closely associated with umbilical artery acid-base status at delivery.
Heart rate variability in normal-weight patients with polycystic ovary syndrome.
Kilit, Celal; Paşalı Kilit, Türkan
2017-05-01
Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.
Nyberg, G
1977-01-01
1 In a double-blind crossover study, six volunteers performed sustained handgrip at 50% of maximal voluntary contraction before and 90 min following oral administration of 0.25 and 100 mg metoprolol tartrate, a beta1 selective adrenoceptor blocking agent. Blood pressure and heart rate were measured with the Auto-Manometer, an electronic semi-automatic device based on the principles of the London School of Hygiene and Tropical Medicine sphygmomanometer. It eliminates observer and digital bias completely, and also records heart rate at the same time as blood pressure is recorded. 2 Resting heart rate fell 15% after 25 mg, 21% after 100 mg and was unchanged after placebo. Systolic blood pressure fell 6% on both doses and was unchanged on placebo. Diastolic pressure did not change with any of the doses. 3 At 1 min of handgrip, heart rate was significantly lower after 25 and 100 mg than before drug or after placebo. There was no difference between the blood pressure levels attained before or after any of the dose levels. The rise of heart rate tended to be somewhat dampened after 100 mg only. The rise in blood pressure was unchanged after any dose compared with before. Images Figure 1 PMID:901695
Heart failure after conventional metal-on-metal hip replacements
Gillam, Marianne H; Pratt, Nicole L; Inacio, Maria C S; Roughead, Elizabeth E; Shakib, Sepehr; Nicholls, Stephen J; Graves, Stephen E
2017-01-01
Background and purpose — It is unclear whether metal particles and ions produced by mechanical wear and corrosion of hip prostheses with metal-on-metal (MoM) bearings have systemic adverse effects on health. We compared the risk of heart failure in patients with conventional MoM total hip arthroplasty (THA) and in those with metal-on-polyethylene (MoP) THA. Patients and methods — We conducted a retrospective cohort study using data from the Australian Government Department of Veterans’ Affairs health claims database on patients who received conventional THA for osteoarthritis between 2004 and 2012. The MoM THAs were classified into groups: Articular Surface Replacement (ASR) XL Acetabular System, other large-head (LH) (> 32 mm) MoM, and small-head (SH) (≤ 32 mm) MoM. The primary outcome was hospitalization for heart failure after THA. Results — 4,019 patients with no history of heart failure were included (56% women). Men with an ASR XL THA had a higher rate of hospitalization for heart failure than men with MoP THA (hazard ratio (HR) = 3.2, 95% CI: 1.6–6.5). No statistically significant difference in the rate of heart failure was found with the other LH MoM or SH MoM compared to MoP in men. There was no statistically significant difference in heart failure rate between exposure groups in women. Interpretation — An association between ASR XL and hospitalization for heart failure was found in men. While causality between ASR XL and heart failure could not be established in this study, it highlights an urgent need for further studies to investigate the possibility of systemic effects associated with MoM THA. PMID:27759468
Sasaki, Takashi; Takeda, Yuko; Ohnakatomi, Yasuko; Asou, Toshihide
2016-09-01
The preferred surgical approach for systemic-pulmonary shunts has changed from thoracotomy to sternotomy in our institution, to concomitantly manage the ductus arteriosus during surgery. The purpose of this study was to compare the outcomes of systemic-pulmonary shunts for neonates with functionally univentricular hearts based on surgical approach. Fifty-two neonates with functionally univentricular hearts underwent systemic-pulmonary shunt via sternotomy (n = 28) or thoracotomy (n = 24). Patient characteristics, achievement rates of right heart bypass, and survival rates were compared for the different approaches. Prenatal diagnosis was made more common in the sternotomy group (p = 0.006). The shunt was placed more centrally in the sternotomy group. The ductus arteriosus was ligated or banded in most patients in the sternotomy group (26/28) and in a few patients in the thoracotomy group (6/24). Frequency of ductal management in the early postoperative phase was not different between the groups (21 vs 25 %), but three new incisions had to be made in the thoracotomy group. No differences were seen in the achievement rates of bidirectional cavopulmonary shunts (86 vs 87 % at 10 months of age) and total cavopulmonary connection (81 vs 81 % at 2 years of age), or in the survival rates (92 vs 96 % at 8 years). There were no differences in short- and long-term outcomes between the groups. The sternotomy approach might be preferable in the current era of prenatal diagnosis, to allow simultaneous duct management during systemic-pulmonary shunt surgery, particularly in patients with large ducts associated with functionally univentricular hearts.
Casilda-López, Jesús; Valenza, Marie Carmen; Cabrera-Martos, Irene; Díaz-Pelegrina, Ana; Moreno-Ramírez, Maria Paz; Valenza-Demet, Gerald
2017-07-01
To evaluate the effects of a dance-based aquatic exercise program on functionality, cardiorespiratory capacity, postexercise heart rate, and fatigue in obese postmenopausal women with knee osteoarthritis. A randomized controlled trial was performed. In all, 34 obese women diagnosed with knee osteoarthritis participated. Women were randomly allocated to an experimental group (n = 17) or a control group (n = 17). Participants in the experimental group were included in an 8-week dance-based aquatic exercise program conducted in community swimming pools. Those in the control group underwent a global aquatic exercise program. The primary outcome measure was functionality assessed with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Secondary outcomes were cardiorespiratory capacity evaluated with the 6-minute walk test, and postexercise heart rate and fatigue assessed using a visual analog scale. Variables were measured at baseline, after the intervention, and at 3-month follow-up. A between-group analysis showed significant postintervention differences in functionality (aggregate postintervention WOMAC score of 37.30 ± 16.61 vs 41.83 ± 13.69; P = 0.048) in favor of the experimental group. In addition, significant between-group differences were found after the 8 weeks in cardiorespiratory capacity, postexercise heart rate, and fatigue. Follow-up continued to show significant differences between groups in function (aggregate WOMAC score of 38.60 ± 13.61 vs 42.60 ± 9.05; P = 0.038), postexercise heart rate, and fatigue. An 8-week dance-based exercise program significantly improved function and cardiorespiratory capacity, and decreased postexercise heart rate and fatigue. Most of these improvements were maintained at 3-month follow-up in obese postmenopausal women.
Abernethy, P; Batman, P
1994-01-01
The purpose of the investigation was to determine the relative oxygen consumption (VO2), heart rate and oxygen pulse associated with the constituent elements of an exercise-to-music class. Six women exercise-to-music leaders with a mean(s.d.) age, weight and height of 33.2(5.2) years, 51.0(2.8) kg and 157.9(5.6) cm respectively, completed five distinct exercise-to-music movement elements. The movement elements were of a locomoter (circuit, jump and low impact) and callisthenic (prone and side/supine) nature. The movement elements were distinguishable from one another in terms of their movement patterns, posture and tempo. Relative VO2 values were greatest for the circuit element (40.6 ml kg-1 min-1) and least for the side/supine element (20.0 ml kg-1 min-1). The differences in VO2 between the locomotrr and callisthenic elements were significant (circuit approximately jump approximately low impact > prone approximately side/supine). However, effect size data suggested that the differences between the low impact and jump elements and the prone and side/supine elements were of practical significance (circuit approximately jump > low impact > prone > side/supine). With a single exception similar parametric statistics and effect size trends were identified for absolute heart rate. Specifically, the heart rate associated with the low impact element was not significantly greater than the prone element. The oxygen pulse associated with the locomotor elements was significantly greater than the callisthenic elements (circuit approximately jump approximately low impact > prone > side/supine). This suggested that heart rate may be an inappropriate index for making comparisons between exercise-to-music elements. Reasons for differences in oxygen uptake values between movement elements are discussed. PMID:8044493
Astrand, Annika; Bohlooly-Y, Mohammad; Larsdotter, Sara; Mahlapuu, Margit; Andersén, Harriet; Tornell, Jan; Ohlsson, Claes; Snaith, Mike; Morgan, David G A
2004-10-01
Melanin-concentrating hormone (MCH) plays an important role in energy balance. The current studies were carried out on a new line of mice lacking the rodent MCH receptor (MCHR1(-/-) mice). These mice confirmed the previously reported lean phenotype characterized by increased energy expenditure and modestly increased caloric intake. Because MCH is expressed in the lateral hypothalamic area, which also has an important role in the regulation of the autonomic nervous system, heart rate and blood pressure were measured by a telemetric method to investigate whether the increased energy expenditure in these mice might be due to altered autonomic nervous system activity. Male MCHR1(-/-) mice demonstrated a significantly increased heart rate [24-h period: wild type 495 +/- 4 vs. MCHR1(-/-) 561 +/- 8 beats/min (P < 0.001); dark phase: wild type 506 +/- 8 vs. MCHR1(-/-) 582 +/- 9 beats/min (P < 0.001); light phase: wild type 484 +/- 13 vs. MCHR1(-/-) 539 +/- 9 beats/min (P < 0.005)] with no significant difference in mean arterial pressure [wild type 110 +/- 0.3 vs. MCHR1(-/-) 113 +/- 0.4 mmHg (P > 0.05)]. Locomotor activity and core body temperature were higher in the MCHR1(-/-) mice during the dark phase only and thus temporally dissociated from heart rate differences. On fasting, wild-type animals rapidly downregulated body temperature and heart rate. MCHR1(-/-) mice displayed a distinct delay in the onset of this downregulation. To investigate the mechanism underlying these differences, autonomic blockade experiments were carried out. Administration of the adrenergic antagonist metoprolol completely reversed the tachycardia seen in MCHR1(-/-) mice, suggesting an increased sympathetic tone.
NASA Technical Reports Server (NTRS)
Evans, J. M.; Ziegler, M. G.; Patwardhan, A. R.; Ott, J. B.; Kim, C. S.; Leonelli, F. M.; Knapp, C. F.
2001-01-01
The autonomic nervous system drives variability in heart rate, vascular tone, cardiac ejection, and arterial pressure, but gender differences in autonomic regulation of the latter three parameters are not well documented. In addition to mean values, we used spectral analysis to calculate variability in arterial pressure, heart rate (R-R interval, RRI), stroke volume, and total peripheral resistance (TPR) and measured circulating levels of catecholamines and pancreatic polypeptide in two groups of 25 +/- 1.2-yr-old, healthy men and healthy follicular-phase women (40 total subjects, 10 men and 10 women per group). Group 1 subjects were studied supine, before and after beta- and muscarinic autonomic blockades, administered singly and together on separate days of study. Group 2 subjects were studied supine and drug free with the additional measurement of skin perfusion. In the unblocked state, we found that circulating levels of epinephrine and total spectral power of stroke volume, TPR, and skin perfusion ranged from two to six times greater in men than in women. The difference (men > women) in spectral power of TPR was maintained after beta- and muscarinic blockades, suggesting that the greater oscillations of vascular resistance in men may be alpha-adrenergically mediated. Men exhibited muscarinic buffering of mean TPR whereas women exhibited beta-adrenergic buffering of mean TPR as well as TPR and heart rate oscillations. Women had a greater distribution of RRI power in the breathing frequency range and a less negative slope of ln RRI power vs. ln frequency, both indicators that parasympathetic stimuli were the dominant influence on women's heart rate variability. The results of our study suggest a predominance of sympathetic vascular regulation in men compared with a dominant parasympathetic influence on heart rate regulation in women.
Katheria, Anup; Rich, Wade; Finer, Neil
2012-11-01
To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions.
Ergonomic Intervention on the Occupational Stress of Selective Railway Workshop's Fitters
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Partha; Dey, Netai Chandra
2017-12-01
In India, progressively rigorous health, safety and environmental regulation, together with rapid technological advances have caused job demands of man machine interface. Any deviations in implementing rules and regulations leave many workers at severe risks. In different railway workshops where periodic overhauling (POH) of different coaches and locomotives are obtained, the exhaustive nature of work results strain within the workers. Unfortunately physiological work studies on railway workers are highly inadequate in India. The present study is aimed to relate the ergonomic intervention on the occupational stress of railway workshop's fitters. Working heart rate (WHR) is measured continuously during their work schedule by portable heart rate monitor. Recovery heart rate and other essential occupational stress indexes are also measured along with total working environmental details. The working heart rate (WHR) of the subjects are found as 138 beats/min (bpm) and 121 bpm for the junior (age < 40 years) and senior fitters (age > 40 years), respectively. Net cardiac cost (NCC) and relative cardiac cost (RCC) values exhibit their range in a non-safe zone. No recovery in resting heart rate denotes the hostile environmental effect on the worker's physiology. The effective temperature (ET) and wet bulb globe temperature (WBGT) of work site cross the recommended value. Clear evidences of a direct relationship between occupational hazard and fatigue is found and it can be considered as an environmental stresses which, in conjunction with other environmental and host factors induced a chronic fatigue that lead to non-specific health disorders.
Marek, W; Marek, E; Vogel, P; Mückenhoff, K; Kotschy-Lang, N
2008-11-01
AIMS OF THE INVESTIGATION: The 6-minute-walk-test (6-MW) is an effective tool for measuring physical fitness in elderly patients. The increased walking distance is taken as a parameter for improved physical conditions. Frequently an unaltered walking distance is found after clinical treatment, but heart rate is significantly lower in the second challenge, indicating an improved physical fitness. This positive effect is not recognised when only the walking distance is analysed. An analysis of the 6-MW test was performed on 263 patients before and after 3 - 4 weeks clinical rehabilitation. In a control group of 26 patients 6-MW was repeated after recovery at the beginning and the end of the clinical treatment. Instrumented by a mobile pulse oximeter for recording oxygen saturation and heart rate, patients were instructed to walk as fast as they can do during 6 minutes. Measurements were performed every 30 seconds and printed out. Two new parameters, efficiency (E = S/f (C)), the ratio of distance and mean heart rate, and the theoretical increase in walking distance (S (z) = Delta f (C1)/Delta f (C2) x S (2) - S (1)) were introduced and tested. S (z) = theoretical increase in distance, Delta f (C1) = difference in heart rate at rest and mean heart rate at steady state during the first walk test with distance, S1. Delta f (C2), and S2 are measured during the second walk. Thus, the increase in distance is calculated under the assumption that the second walk test would have been performed by the patient with the same difference in heart rate that he/she achieved in the first walk. The patient groups walked 353 +/- 80 m at 106 +/- 14.3 beats/min in the 1st. 6-MW and 368 +/- 76.9 m at a heart rate of 105 +/- 14.0 beats/min in the final test. The increase of the walking distance was most significant in patients with shorter distances in the 1st 6-MW. A significant increase in the walking distance and in efficiency was found in patients with shorter walking distances or lower heart rates in the final test, using the numerical procedure described above. The patient's performance of the second walk test with an unchanged distance at a lower heart rate reveals an improved physical fitness. This is solely described by an increase by the parameter of efficiency, E. The calculation of the parameter, Sz, theoretical difference in walking distance (i. e., theoretical increase in almost all tests) provides a quantification of the effect of exercise training, even if the patient is not cooperative during the tests. Both parameters have proved to be suitable estimations for the assessment of physical fitness as a beneficial effect of clinical rehabilitation.
ERIC Educational Resources Information Center
Sijtsema, Jelle J.; Veenstra, Rene; Lindenberg, Siegwart; van Roon, Arie M.; Verhulst, Frank C.; Ormel, Johan; Riese, Harriette
2010-01-01
Objective: Why is low resting heart rate (HR) associated with antisocial behavior (ASB), i.e., aggression and rule breaking, in adolescence? Theory suggests that personality traits mediate this relationship but differently with age. In the present study this age-effect hypothesis is tested; we expected that the relationship between HR and…
ERIC Educational Resources Information Center
Scarpa, Angela; Tanaka, Akiho; Haden, Sara Chiara
2008-01-01
In order to more fully understand how individual differences influence adaptation to violence, this study examined the moderating influence of resting heart rate (HR) and HR variability (HRV) between community violence (CV) exposure and child reactive/proactive aggression. Forty 7-13-year-old community children self-reported CV exposure (i.e.,…
ERIC Educational Resources Information Center
Crone, Eveline A.; Somsen, Riek J. M.; Zanolie, Kiki; Van der Molen, Maurits W.
2006-01-01
Over the course of development, the ability to switch between different tasks on the basis of feedback cues increases profoundly, but the role of performance monitoring remains unclear. Heart rate indexes can provide critical information about how individuals monitor feedback cues indicating that performance should be adjusted. In this study,…
ERIC Educational Resources Information Center
Crone, Eveline A.; van der Molen, Maurits W.
2007-01-01
Age differences in decision making indicate that children fail to anticipate outcomes of their decisions. Using heart rate and skin conductance analyses, we tested whether developmental changes in decision making are associated with (a) a failure to process outcomes of decisions, or (b) a failure to anticipate future outcomes of decisions.…
Evaluating the Prediction of Maximal Heart Rate in Children and Adolescents
ERIC Educational Resources Information Center
Mahon, Anthony D.; Marjerrison, Andrea D.; Lee, Jonah D.; Woodruff, Megan E.; Hanna, Lauren E.
2010-01-01
In this study, we compared measured maximal heart rate (HRmax) to two different HRmax prediction equations [220-age and 208-0.7(age)] in 52 children ages 7-17 years. We determined the relationship of chronological age, maturational age, and resting HR to measured HRmax and assessed seated resting HR and HRmax during a graded exercise test.…
Heart Rate and VO[subscript 2] Responses to Cycle Ergometry in White and African American Men
ERIC Educational Resources Information Center
Vehrs, Pat R.; Fellingham, Gilbert W.
2006-01-01
The validity of estimates of peak oxygen consumption (VO[subscript 2]peak) using submaximal exercise tests may be compromised when the participants being tested are not similar to the participants used to develop the test. This study compared ethnic differences in the heart rate (HR) and oxygen consumption (VO[subscript 2]) responses to submaximal…
Prophylactic versus therapeutic amnioinfusion for oligohydramnios in labour.
Novikova, Natalia; Hofmeyr, G Justus; Essilfie-Appiah, George
2012-09-12
Amnioinfusion aims to relieve umbilical cord compression during labour by infusing a liquid into the uterine cavity. The objective of this review was to assess the effects of prophylactic amnioinfusion for women in labour with oligohydramnios, but not fetal heart deceleration, compared with therapeutic amnioinfusion only if fetal heart rate decelerations or thick meconium-staining of the liquor occur. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (28 February 2012). Randomised trials comparing prophylactic amnioinfusion in women in labour with oligohydramnios but not fetal heart rate deceleration in labour with therapeutic amnioinfusion. The authors assessed trial quality and extracted data. One randomized trial of 116 women was included. No differences were found in the rate of caesarean section (risk ratio 1.29, 95% confidence interval 0.60 to 2.74). There were no differences in cord arterial pH, oxytocin augmentation, neonatal pneumonia or postpartum endometritis. Prophylactic amnioinfusion was associated with increased intrapartum fever (risk ratio 3.48, 95% confidence interval 1.21 to 10.05). There appears to be no advantage of prophylactic amnioinfusion over therapeutic amnioinfusion carried out only when fetal heart rate decelerations or thick meconium-staining of the liquor occur.
Gaussian Mixture Model of Heart Rate Variability
Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario
2012-01-01
Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386
Optimization of pharmacotherapy in chronic heart failure: is heart rate adequately addressed?
Franke, Jennifer; Wolter, Jan Sebastian; Meme, Lillian; Keppler, Jeannette; Tschierschke, Ramon; Katus, Hugo A; Zugck, Christian
2013-01-01
The aim of the study is to evaluate the use of beta-blockers in chronic heart failure (CHF) and the extent of heart rate reduction achieved in clinical practice and to determine differences in outcome of patients who fulfilled select inclusion criteria of the SHIFT study according to resting heart rate modulated by beta-blocker therapy. We evaluated an all-comer population of our dedicated CHF outpatient clinic between 2006 and 2010. For inclusion, individually optimized doses of guideline-recommended pharmacotherapy including beta-blockers had to be maintained for at least 3 months and routine follow-up performed at our outpatient CHF-clinic thereafter. Treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate were assessed. The outcome of patients who fulfilled select inclusion criteria of the SHIFT study (left-ventricular ejection fraction (LVEF) ≤35 %, sinus rhythm, NYHA II-IV) and were followed-up for at least 1 year was stratified according to resting heart rates: ≥75 versus <75 bpm and ≥70 versus <70 bpm. The composite primary endpoint was defined as all-cause death or hospital admission for worsening heart failure during 12-month follow-up. In total, 3,181 patients were assessed in regard to treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate. Of the overall studied population, 443 patients fulfilled all inclusion criteria and entered outcome analysis. Median observation time of survivors was 27.5 months with 1,039.7 observation-years in total. Up-titration to at least half the evidence-based target dose of beta-blockers was achieved in 69 % and full up-titration in 29 % of these patients. Patients with increased heart rates were younger, more often male, exhibited a higher NYHA functional class and lower LVEF. The primary endpoint occurred in 21 % of patients in the ≥70 bpm group versus 9 % of patients in the group with heart rates <70 bpm (p <0.01). Likewise, comparing the groups ≥75 and <75 bpm, the primary endpoint was significantly increased in the group of patients with heart rates ≥75 bpm 27 vs. 12.2 %; p < 0.01). 5-year event-free survival was significantly lower among patients with heart rates ≥70 bpm as compared to those with <70 bpm (log-rank test p < 0.05) and among patients in the ≥75 bpm group versus <75 bpm group (log-rank test p < 0.01). In conclusion, in clinical practice, 53 % of CHF patients have inadequate heart rate control (heart rates ≥75 bpm) despite concomitant beta-blocker therapy. In this non-randomized cohort, adequate heart rate control under individually optimized beta-blocker therapy was associated with improved mid- and long-term clinical outcome up to 5 years. As further up titration of beta-blockers is not achievable in many patients, the administration of a selective heart rate lowering agent, such as ivabradine adjuvant to beta-blockers may pose an opportunity to further modulate outcome.
The effect of restraining on the heart rate in guinea pigs
NASA Technical Reports Server (NTRS)
Mikiskova, H.
1980-01-01
The emotional effect of different applications of electrodes and the fixation for cariographic examination was investigated using guinea pigs. The effect of the stress is discussed in terms of heart rhythm and behavior.
Makimoto, Hisaki; Blockhaus, Christian; Meyer, Christian; Lin, Tina; Jungen, Christiane; Eickholt, Christian; Clasen, Lukas; Schmidt, Jan; Kurt, Muhammed; Müller, Patrick; Shin, Dong-In; Kelm, Malte; Fürnkranz, Alexander
2018-03-01
The severity of symptoms during atrial fibrillation (AF) may be influenced by heart rate and blood pressure variation, due to irregular beats and the related adaptations in baroreflex sensitivity. This study investigated whether heart rate turbulence (HRT) as a reflection of baroreflex sensitivity is related to symptom severity during AF. Ninety-seven patients (pts) who underwent electrophysiological study were enrolled. Consecutive 56 pts had paroxysmal AF (21 with milder symptoms [EHRA I or II; Group-M], 35 with severe symptoms [EHRA III or IV; Group-S]), and 41 age-matched controls without AF were included. After delivering a single ventricular extrastimulus during sinus rhythm and repeating the process 10 times, the quantification of HRT was performed by measuring turbulence onset (TO: heart rate acceleration) and turbulence slope (TS: rate of heart rate deceleration). Group-M pts showed significantly diminished TO as compared to controls and Group-S pts (P = 0.012). There was no significant difference of the TS between the 3 groups. Given that a TO ≥ 0% or TS ≤ 2.5 ms/RR was considered abnormal, Group-M pts showed significantly higher incidences of abnormal HRT as compared to controls and Group-S pts (71% vs 40% vs 21%, respectively, P = 0.0012). Regression analysis demonstrated an independent and significant association between a diminished TO and milder AF symptoms (P < 0.05). The usual heart rate acceleration after premature ventricular contraction is significantly diminished in pts with milder AF symptoms as compared to pts with severe AF symptoms. The mechanism of association between this diminished response and symptoms should be further investigated.
Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa
2008-01-01
The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe. PMID:18327970
Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa
2008-01-01
The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.
Moses, Monday Omoniyi; Osei, Francis; Appiah, Eric Juniour; Obour, Agnes; Akwa, Lady Gwendoline; Baffour-Awuah, Biggie; Asamoah, Benjamin; Sarpong, Peter Akwasi; Adams, Caleb; D’Onofrio, Rosario
2017-01-01
This study examined and compared, based on year of study and gender, the health and performance indices of university undergraduate students. Eighty-nine students (mean±standard deviation age, 22.47±2.22 years) were randomly selected for assessment prior to second semester examination of 2015/2016 academic year. body mass index, resting metabolic rate, visceral fat, skeletal muscle mass, body fat, systolic & diastolic blood pressure, resting heart rate, upper & lower body endurance, handgrip strength, and lower back and hamstring flexibility were assessed. The students had sedentary heart rate, low skeletal muscle mass, average upper and lower body endurance, and weak handgrip strength. Significant difference existed in the visceral fat (P=0.008) between third and fourth year students. There were significant gender differences in resting metabolic rate (P=0.000), skeletal muscle mass (P=0.000), body fat (P=0.000), systolic blood pressure (P=0.001), heart rate (P=0.005) and handgrip strength (P=0.000). There are gender differences in association between health and performance indices. Dependable health education and pragmatic involvement of undergraduate university students in structured exercise programmes are recommended. PMID:29114505
Verdiani, Valerio; Lastrucci, Vieri; Nozzoli, Carlo
2010-10-11
Objectives. To determine the prevalence, the clinical predictors, and the prognostic significances of Worsening Renal Function (WRF) in hospitalized patients with Acute Heart Failure (AHF). Methods. 394 consecutively hospitalized patients with AHF were evaluated. WRF was defined as an increase in serum creatinine of ≥0.3 mg/dL from baseline to discharge. Results. Nearly 11% of patients developed WRF. The independent predictors of WRF analyzed with a multivariable logistic regression were history of chronic kidney disease (P = .047), age >75 years (P = .049), and admission heart rates ≥100 bpm (P = .004). Mortality or rehospitalization rates at 1 month, 6 months, and 1year were not significantly different between patients with WRF and those without WRF. Conclusion. Different clinical predictors at hospital admission can be used to identify patients at increased risk for developing WRF. Patients with WRF compared with those without WRF experienced no significant differences in hospital length of stay, mortality, or rehospitalization rates.
Verdiani, Valerio; Lastrucci, Vieri; Nozzoli, Carlo
2011-01-01
Objectives. To determine the prevalence, the clinical predictors, and the prognostic significances of Worsening Renal Function (WRF) in hospitalized patients with Acute Heart Failure (AHF). Methods. 394 consecutively hospitalized patients with AHF were evaluated. WRF was defined as an increase in serum creatinine of ≥0.3 mg/dL from baseline to discharge. Results. Nearly 11% of patients developed WRF. The independent predictors of WRF analyzed with a multivariable logistic regression were history of chronic kidney disease (P = .047), age >75 years (P = .049), and admission heart rates ≥100 bpm (P = .004). Mortality or rehospitalization rates at 1 month, 6 months, and 1year were not significantly different between patients with WRF and those without WRF. Conclusion. Different clinical predictors at hospital admission can be used to identify patients at increased risk for developing WRF. Patients with WRF compared with those without WRF experienced no significant differences in hospital length of stay, mortality, or rehospitalization rates. PMID:21188211
Van Dyke, Miriam E; Komro, Kelli A; Shah, Monica P; Livingston, Melvin D; Kramer, Michael R
2018-07-01
Despite substantial declines since the 1960's, heart disease remains the leading cause of death in the United States (US) and geographic disparities in heart disease mortality have grown. State-level socioeconomic factors might be important contributors to geographic differences in heart disease mortality. This study examined the association between state-level minimum wage increases above the federal minimum wage and heart disease death rates from 1980 to 2015 among 'working age' individuals aged 35-64 years in the US. Annual, inflation-adjusted state and federal minimum wage data were extracted from legal databases and annual state-level heart disease death rates were obtained from CDC Wonder. Although most minimum wage and health studies to date use conventional regression models, we employed marginal structural models to account for possible time-varying confounding. Quasi-experimental, marginal structural models accounting for state, year, and state × year fixed effects estimated the association between increases in the state-level minimum wage above the federal minimum wage and heart disease death rates. In models of 'working age' adults (35-64 years old), a $1 increase in the state-level minimum wage above the federal minimum wage was on average associated with ~6 fewer heart disease deaths per 100,000 (95% CI: -10.4, -1.99), or a state-level heart disease death rate that was 3.5% lower per year. In contrast, for older adults (65+ years old) a $1 increase was on average associated with a 1.1% lower state-level heart disease death rate per year (b = -28.9 per 100,000, 95% CI: -71.1, 13.3). State-level economic policies are important targets for population health research. Copyright © 2018 Elsevier Inc. All rights reserved.
Baranchuk, Adrian; Healey, Jeff S; Thorpe, Kevin E; Morillo, Carlos A; Nair, Girish; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J
2007-08-01
Although several randomized trials have detected no reduction in major cardiovascular events with the routine use of dual-chamber as opposed to ventricular pacemakers, many individuals continue to advocate their use as a means of improving exercise capacity. The Canadian Trial of Physiological Pacing (CTOPP) trial is the largest trial comparing ventricular pacing to atrial-based pacing (atrial or dual-chamber) in patients with bradycardia. All patients in this trial were asked to complete a 6-minute hall walk test (6MWT) at the time of their first study follow-up. The distance walked in 6 minutes and the patient's heart rate before and immediately after the walk were recorded. Of the 2568 patients in the CTOPP, 76% completed the 6MWT. The mean distance walked was 350 +/- 127 m in the ventricular pacing group and 356 +/- 127 m in the atrial-based group (P = NS). Similarly, there was no difference in the change in heart rate between the two groups (17 +/- 13 vs. 18 +/- 12 bpm: P = NS). However, among patients with an unpaced heart rate of =60 bpm, patients assigned to atrial-based pacing walked farther than those randomized to ventricular pacing (361 +/- 127 vs. 343 +/- 121 m; P = .04). This was not associated with a difference in heart rate. The use of rate-adaptive pacing, irrespective of the pacing mode, resulted in a greater increase in heart rate with the 6MWT but no increase in the total distance walked. The routine use of atrial-based pacemakers, instead of ventricular pacemakers, does not improve exercise capacity, as measured by the 6MWT. However, patients with an unpaced heart rate of =60 bpm may achieve a modest increase in their exercise capacity with atrial-based pacing.
Effect of uterine contractions on fetal heart rate in pregnancy: a prospective observational study.
Sletten, Julie; Kiserud, Torvid; Kessler, Jörg
2016-10-01
The new Holter monitoring technology enables long-term electrocardiographic recording of the fetal heart rate without discomfort for the mother. The aim of the study was to assess the feasibility of a fetal Holter monitor. This technology was further used to study fetal heart rate outside the hospital setting during normal daily activities and to test the hypothesis that uterine activity during pregnancy influences fetal heart rate. Prospective observational study including 12 healthy pregnant women at 20-40 weeks of gestation. Data were collected using the Monica AN24 system. Outcome measures were fetal heart rate, maternal heart rate, and uterine activity categorized according to the strength of the electrohysterographic signal. The recordings had a median length of 18.8 h, and fetal heart rate and maternal heart rate were obtained with success rates of 73.1 and 99.9%, respectively. Uterine activity was found to affect fetal heart rate in all participants. Compared with the basal tone and mild levels of uterine activity, moderate and strong levels of uterine activity were associated with increases in fetal heart rate of 4.0 and 5.7 beats/min, respectively. At night, the corresponding increases were 4.9 and 7.6 beats/min. Linear correlations were found between maternal heart rate and fetal heart rate in 11 of the 12 cases, with a mean coefficient beta of 0.189. Both maternal heart rate and fetal heart rate exhibited a diurnal pattern, with lower heart rates being recorded at night. Uterine activity during pregnancy is associated with a graded response in fetal heart rate and may represent a physiological challenge for the development and adaptation of the fetal cardiovascular system. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Lo Turco, Giovanni; Grimaldi Di Terresena, Liria
2012-01-01
The aim of this study was to test the primary hypothesis of altered Heart Rate Variability (HRV) and heart rate in a sample of patients with mental disorders and the secondary hypothesis of normalization of HRV values as a result of clinical improvement. The study was conducted on a sample of 90 patients with psychotic, anxiety and mood disorders. Each patient was subjected to detection of HRV and heart rate via a photoplethysmographic sensor and evaluated with rating scales based on the specific disorder. The parameters detected in the sample were compared with a control group of healthy subjects. There were no significant differences of cardiac autonomic modulation between the group of patients in whom is possible exclude the drug influence and the control group; significantly lower values of HRV parameters in the group of patients with drug influence, and especially in subgroup of psychotic patients, compared to controls, are, instead, detected. The study also shows a significant increase in heart rate as a common feature in mental disorders, regardless of treatment. Clinical improvement appears to promote the normalization of the variability in patients with high DS of tachogram. The study suggests a potential increased risk of cardiovascular mortality in patients, as evidenced by the increased values of heart rate, regardless of drug treatment. This risk is even more pronounced in psychotic patients in drug treatment because of the simultaneous significant reduction of HRV parameters.
Role of ivabradine in management of stable angina in patients with different clinical profiles
Kaski, Juan Carlos; Gloekler, Steffen; Ferrari, Roberto; Fox, Kim; Lévy, Bernard I; Komajda, Michel; Vardas, Panos; Camici, Paolo G
2018-01-01
In chronic stable angina, elevated heart rate contributes to the development of symptoms and signs of myocardial ischaemia by increasing myocardial oxygen demand and reducing diastolic perfusion time. Accordingly, heart rate reduction is a well-known strategy for improving both symptoms of myocardial ischaemia and quality of life (QOL). The heart rate-reducing agent ivabradine, a direct and selective inhibitor of the I f current, decreases myocardial oxygen consumption while increasing diastolic time, without affecting myocardial contractility or coronary vasomotor tone. Ivabradine is indicated for treatment of stable angina and chronic heart failure (HF). This review examines available evidence regarding the efficacy and safety of ivabradine in stable angina, when used as monotherapy or in combination with beta-blockers, in particular angina subgroups and in patients with stable angina with left ventricular systolic dysfunction (LVSD) or HF. Trials involving more than 45 000 patients receiving treatment with ivabradine have shown that this agent has antianginal and anti-ischaemic effects, regardless of age, sex, severity of angina, revascularisation status or comorbidities. This heart rate-lowering agent might also improve prognosis, reduce hospitalisation rates and improve QOL in angina patients with chronic HF and LVSD. PMID:29632676
Ethnic Minorities and Coronary Heart Disease: an Update and Future Directions
Leigh, J. Adam; Alvarez, Manrique
2016-01-01
Heart disease remains the leading cause of death in the USA. Overall, heart disease accounts for about 1 in 4 deaths with coronary heart disease (CHD) being responsible for over 370,000 deaths per year. It has frequently and repeatedly been shown that some minority groups in the USA have higher rates of traditional CHD risk factors, different rates of treatment with revascularization procedures, and excess morbidity and mortality from CHD when compared to the non-Hispanic white population. Numerous investigations have been made into the causes of these disparities. This review aims to highlight the recent literature which examines CHD in ethnic minorities and future directions in research and care. PMID:26792015
Ethnic Minorities and Coronary Heart Disease: an Update and Future Directions.
Leigh, J Adam; Alvarez, Manrique; Rodriguez, Carlos J
2016-02-01
Heart disease remains the leading cause of death in the USA. Overall, heart disease accounts for about 1 in 4 deaths with coronary heart disease (CHD) being responsible for over 370,000 deaths per year. It has frequently and repeatedly been shown that some minority groups in the USA have higher rates of traditional CHD risk factors, different rates of treatment with revascularization procedures, and excess morbidity and mortality from CHD when compared to the non-Hispanic white population. Numerous investigations have been made into the causes of these disparities. This review aims to highlight the recent literature which examines CHD in ethnic minorities and future directions in research and care.
Uzeda, Marcelo José; Moura, Brenda; Louro, Rafael Seabra; da Silva, Licínio Esmeraldo; Calasans-Maia, Mônica Diuana
2014-05-01
The control of hypertensive patients' blood pressure and heart rate using vasoconstrictors during surgical procedures under anesthesia is still a major concern in everyday surgical practice. This clinical trial aimed to evaluate the variation of blood pressure and heart rate in nonhypertensive and controlled hypertensive voluntary subjects undergoing oral surgery under local anesthesia with lidocaine hydrochloride and epinephrine at 1:100,000 (Alphacaine; DFL, Brazil), performed in the Oral Surgery Department, Dentistry School, Fluminense Federal University. In total, 25 voluntary subjects were divided into 2 groups: nonhypertensive (n = 15) and controlled hypertensives (n = 10). Blood pressure and heart rate were measured at 4 different times: T0, in the waiting room; T1, after placement of the surgical drapes; T2, 10 minutes after anesthesia injection; and T3, at the end of the surgical procedure. A statistically significant difference (P < 0.05) between the groups was found at times T0 and T2 for the systolic pressure but only at time T0 for the diastolic pressure. The assessment of the heart rate of both groups showed a statistically significant difference (P < 0.05) at time T1. An analysis of the employed anesthetic volume indicated no statistically significant difference (P > 0.05) between the amount administered to nonhypertensive and hypertensive subjects. It was concluded that the local anesthetics studied could safely be used in controlled hypertensive and nonhypertensive patients in compliance with the maximum recommended doses.
Visibility graph analysis of heart rate time series and bio-marker of congestive heart failure
NASA Astrophysics Data System (ADS)
Bhaduri, Anirban; Bhaduri, Susmita; Ghosh, Dipak
2017-09-01
Study of RR interval time series for Congestive Heart Failure had been an area of study with different methods including non-linear methods. In this article the cardiac dynamics of heart beat are explored in the light of complex network analysis, viz. visibility graph method. Heart beat (RR Interval) time series data taken from Physionet database [46, 47] belonging to two groups of subjects, diseased (congestive heart failure) (29 in number) and normal (54 in number) are analyzed with the technique. The overall results show that a quantitative parameter can significantly differentiate between the diseased subjects and the normal subjects as well as different stages of the disease. Further, the data when split into periods of around 1 hour each and analyzed separately, also shows the same consistent differences. This quantitative parameter obtained using the visibility graph analysis thereby can be used as a potential bio-marker as well as a subsequent alarm generation mechanism for predicting the onset of Congestive Heart Failure.
SenseMyHeart: A cloud service and API for wearable heart monitors.
Pinto Silva, P M; Silva Cunha, J P
2015-01-01
In the era of ubiquitous computing, the growing adoption of wearable systems and body sensor networks is trailing the path for new research and software for cardiovascular intensity, energy expenditure and stress and fatigue detection through cardiovascular monitoring. Several systems have received clinical-certification and provide huge amounts of reliable heart-related data in a continuous basis. PhysioNet provides equally reliable open-source software tools for ECG processing and analysis that can be combined with these devices. However, this software remains difficult to use in a mobile environment and for researchers unfamiliar with Linux-based systems. In the present paper we present an approach that aims at tackling these limitations by developing a cloud service that provides an API for a PhysioNet-based pipeline for ECG processing and Heart Rate Variability measurement. We describe the proposed solution, along with its advantages and tradeoffs. We also present some client tools (windows and Android) and several projects where the developed cloud service has been used successfully as a standard for Heart Rate and Heart Rate Variability studies in different scenarios.
Cubbon, Richard M; Ruff, Naomi; Groves, David; Eleuteri, Antonio; Denby, Christine; Kearney, Lorraine; Ali, Noman; Walker, Andrew M N; Jamil, Haqeel; Gierula, John; Gale, Chris P; Batin, Phillip D; Nolan, James; Shah, Ajay M; Fox, Keith A A; Sapsford, Robert J; Witte, Klaus K; Kearney, Mark T
2016-01-01
Objective We aimed to define the prognostic value of the heart rate range during a 24 h period in patients with chronic heart failure (CHF). Methods Prospective observational cohort study of 791 patients with CHF associated with left ventricular systolic dysfunction. Mode-specific mortality and hospitalisation were linked with ambulatory heart rate range (AHRR; calculated as maximum minus minimum heart rate using 24 h Holter monitor data, including paced and non-sinus complexes) in univariate and multivariate analyses. Findings were then corroborated in a validation cohort of 408 patients with CHF with preserved or reduced left ventricular ejection fraction. Results After a mean 4.1 years of follow-up, increasing AHRR was associated with reduced risk of all-cause, sudden, non-cardiovascular and progressive heart failure death in univariate analyses. After accounting for characteristics that differed between groups above and below median AHRR using multivariate analysis, AHRR remained strongly associated with all-cause mortality (HR 0.991/bpm increase in AHRR (95% CI 0.999 to 0.982); p=0.046). AHRR was not associated with the risk of any non-elective hospitalisation, but was associated with heart-failure-related hospitalisation. AHRR was modestly associated with the SD of normal-to-normal beats (R2=0.2; p<0.001) and with peak exercise-test heart rate (R2=0.33; p<0.001). Analysis of the validation cohort revealed AHRR to be associated with all-cause and mode-specific death as described in the derivation cohort. Conclusions AHRR is a novel and readily available prognosticator in patients with CHF, which may reflect autonomic tone and exercise capacity. PMID:26674986
Ho, Vivian; Ross, Joseph S.; Steiner, Claudia A.; Mandawat, Aditya; Short, Marah; Ku-Goto, Meei-Hsiang; Krumholz, Harlan M.
2016-01-01
Multiple studies claim that public place smoking bans are associated with reductions in smoking-related hospitalization rates. No national study using complete hospitalization counts by area that accounts for contemporaneous controls including state cigarette taxes has been conducted. We examine the association between county-level smoking-related hospitalization rates and comprehensive smoking bans in 28 states from 2001 to 2008. Differences-in-differences analysis measures changes in hospitalization rates before versus after introducing bans in bars, restaurants, and workplaces, controlling for cigarette taxes, adjusting for local health and provider characteristics. Smoking bans were not associated with acute myocardial infarction or heart failure hospitalizations, but lowered pneumonia hospitalization rates for persons ages 60 to 74 years. Higher cigarette taxes were associated with lower heart failure hospitalizations for all ages and fewer pneumonia hospitalizations for adults aged 60 to 74. Previous studies may have overestimated the relation between smoking bans and hospitalizations and underestimated the effects of cigarette taxes. PMID:27624634
Ho, Vivian; Ross, Joseph S; Steiner, Claudia A; Mandawat, Aditya; Short, Marah; Ku-Goto, Meei-Hsiang; Krumholz, Harlan M
2017-12-01
Multiple studies claim that public place smoking bans are associated with reductions in smoking-related hospitalization rates. No national study using complete hospitalization counts by area that accounts for contemporaneous controls including state cigarette taxes has been conducted. We examine the association between county-level smoking-related hospitalization rates and comprehensive smoking bans in 28 states from 2001 to 2008. Differences-in-differences analysis measures changes in hospitalization rates before versus after introducing bans in bars, restaurants, and workplaces, controlling for cigarette taxes, adjusting for local health and provider characteristics. Smoking bans were not associated with acute myocardial infarction or heart failure hospitalizations, but lowered pneumonia hospitalization rates for persons ages 60 to 74 years. Higher cigarette taxes were associated with lower heart failure hospitalizations for all ages and fewer pneumonia hospitalizations for adults aged 60 to 74. Previous studies may have overestimated the relation between smoking bans and hospitalizations and underestimated the effects of cigarette taxes.
Waninge, Aly; van der Putten, Annette A J; Stewart, Roy E; Steenbergen, Bert; van Wijck, Ruud; van der Schans, Cees P
2013-11-01
Because physical fitness and health are related to physical activity, it is important to gain an insight into the physical activity levels of persons with profound intellectual and multiple disabilities (PIMD). The purpose of this study was to examine heart rate patterns to measure the activity levels of persons with PIMD and to analyze these heart rate patterns according to participant characteristics, observed level of activity, days, and time of day. The heart rate patterns of 24 participants with PIMD were measured continuously using a heart rate monitor for 8 h · d for a period of 6 days. Physical activity levels were measured with questionnaires. Data were analyzed using multilevel analysis. The results indicate that the participants use only 32% of their heart rate reserve over 6 days. The intensity of heart rate reserve ranged from 1 to 62%. On a given day, wide ranges in heart rates between participants and within persons were observed. Between days, only small ranges in the heart rate were found. The participants could be grouped into 4 classes according to their heart rate. In addition, factors such as time of day, physical activity, and age are significantly related to heart rate patterns. In conclusion, this study is an important first step in exploring activity patterns based on heart rate patterns in persons with PIMD. The participants used relatively small fractions of their heart rate reserves. Time of day and age appear to have a considerable influence on heart rate patterns. The observed classes in heart rate patterns suggest that other probably more personal and psychosocial factors have significant influences on heart rate patterns, as well.
Human exposure to environmental health concern by types of urban environment: The case of Tel Aviv.
Schnell, Izhak; Potchter, Oded; Yaakov, Yaron; Epstein, Yoram
2016-01-01
This study classifies urban environments into types characterized by different exposure to environmental risk factors measured by general sense of discomfort and Heart Rate Variability (HRV). We hypothesize that a set of environmental factors (micro-climatic, CO, noise and individual heart rate) that were measured simultaneously in random locations can provide a better understanding of the distribution of human exposure to environmental loads throughout the urban space than results calculated based on measurements from close fixed stations. We measured micro-climatic and thermal load, CO and noise, individual Heart Rate, Subjective Social Load and Sense of Discomfort (SD) were tested by questionnaire survey. The results demonstrate significant differences in exposure to environmental factors among 8 types of urban environments. It appears that noise and social load are the more significant environmental factors to enhance health risks and general sense of discomfort. Copyright © 2015 Elsevier Ltd. All rights reserved.
Liu, Hai Lun; Garzoni, Luca; Herry, Christophe; Durosier, Lucien Daniel; Cao, Mingju; Burns, Patrick; Fecteau, Gilles; Desrochers, André; Patey, Natalie; Seely, Andrew J E; Faure, Christophe; Frasch, Martin G
2016-04-01
Necrotizing enterocolitis of the neonate is an acute inflammatory intestinal disease that can cause necrosis and sepsis. Chorioamnionitis is a risk factor of necrotizing enterocolitis. The gut represents the biggest vagus-innervated organ. Vagal activity can be measured via fetal heart rate variability. We hypothesized that fetal heart rate variability can detect fetuses with incipient gut inflammation. Prospective animal study. University research laboratory. Chronically instrumented near-term fetal sheep (n = 21). Animals were surgically instrumented with vascular catheters and electrocardiogram to allow manipulation and recording from nonanesthetized animals. In 14 fetal sheep, inflammation was induced with lipopolysaccharide (IV) to mimic chorioamnionitis. Fetal arterial blood samples were drawn at selected time points over 54 hours post lipopolysaccharide for blood gas and cytokines (interleukin-6 and tumor necrosis factor-α enzymelinked immunosorbent assay). Fetal heart rateV was quantified throughout the experiment. The time-matched fetal heart rate variability measures were correlated to the levels of interleukin-6 and tumor necrosis factor-α. Upon necropsy, ionized calcium binding adaptor molecule 1+ (Iba1+), CD11c+ (M1), CD206+ (M2 macrophages), and occludin (leakiness marker) immunofluorescence in the terminal ileum was quantified along with regional Iba1+ signal in the brain (microglia). Interleukin-6 peaked at 3 hours post lipopolysaccharide accompanied by mild cardiovascular signs of sepsis. At 54 hours, we identified an increase in Iba1+ and, specifically, M1 macrophages in the ileum accompanied by increased leakiness, with no change in Iba1 signal in the brain. Preceding this change on tissue level, at 24 hours, a subset of nine fetal heart rate variability measures correlated exclusively to the Iba+ markers of ileal, but not brain, inflammation. An additional fetal heart rate variability measure, mean of the differences of R-R intervals, correlated uniquely to M1 ileum macrophages increasing due to lipopolysaccharide. We identified a unique subset of fetal heart rate variability measures reflecting 1.5 days ahead of time the levels of macrophage activation and increased leakiness in terminal ileum. We propose that such subset of fetal heart rate variability measures reflects brain-gut communication via the vagus nerve. Detecting such noninvasively obtainable organ-specific fetal heart rate variability signature of inflammation would alarm neonatologists about neonates at risk of developing necrotizing enterocolitis and sepsis. Clinical validation studies are required.
Individually Coded Telemetry: a Tool for Studying Heart Rate and Behaviour in Reindeer Calves
Eloranta, E; Norberg, H; Nilsson, A; Pudas, T; Säkkinen, H
2002-01-01
The aim of the study was to test the performance of a silver wire modified version of the coded telemetric heart rate monitor Polar Vantage NV™ (PVNV) and to measure heart rate (HR) in a group of captive reindeer calves during different behaviour. The technical performance of PVNV HR monitors was tested in cold conditions (-30°C) using a pulse generator and the correlation between generated pulse and PVNV values was high (r = 0.9957). The accuracy was tested by comparing the HR obtained with the PVNV monitor with the standard ECG, and the correlation was significant (r = 0.9965). Both circadian HR and HR related to behavioural pattern were recorded. A circadian rhythm was observed in the HR in reindeer with a minimum during night and early morning hours and maximum at noon and during the afternoon, the average HR of the reindeer calves studied being 42.5 beats/min in February. The behaviour was recorded by focal individual observations and the data was synchronized with the output of the HR monitors. Running differed from all other behavioural categories in HR. Inter-individual differences were seen expressing individual responses to external and internal stimuli. The silver wire modified Polar Vantage NV™ provides a suitable and reliable tool for measuring heart rate in reindeer, also in natural conditions. PMID:12564543
The role of the autonomic nervous system in the resting tachycardia of human hyperthyroidism.
Maciel, B C; Gallo, L; Marin Neto, J A; Maciel, L M; Alves, M L; Paccola, G M; Iazigi, N
1987-02-01
The mechanisms that control resting heart rate in hyperthyroidism were evaluated in six patients before and after treatment with propylthiouracil. The patients were subjected to pharmacological blockade under resting conditions in two experimental sessions: first session, propranolol (0.2 mg/kg body weight); second session, atropine (0.04 mg/kg body weight) followed by propranolol (0.2 mg/kg body weight). All drugs were administered intravenously. Resting heart rate was significantly reduced from 100 +/- 6.5 beats/min to 72 +/- 2.5 beats/min (P less than 0.005) after clinical and laboratory control of the disease. After double blockade, intrinsic heart rate was reduced from 105 +/- 6.8 beats/min before treatment to 98 +/- 6.0 beats/min after treatment (P less than 0.025). The reduction in heart rate caused by propranolol was not significantly different before (-13 +/- 1.4 beats/min) and after (-9 +/- 1.0 beats/min) propylthiouracil. In contrast, atropine induced a higher elevation of heart rate after treatment (45 +/- 8.6 beats/min) than before treatment (26 +/- 4.0 beats/min). The present results suggest no appreciable participation of the sympathetic component of the autonomic nervous system in the tachycardia of hyperthyroidism, at least under the conditions of the present study. The small change observed in intrinsic heart rate, although significant, seems to indicate that this is not the most important mechanism involved in this tachycardia. Our results suggest that an important reduction in the efferent activity of the parasympathetic component participates in the mechanisms that modify resting heart rte in hyperthyroidism.
Labranche, D; Mestre-Fernandes, C; Delahaye, F; Sanchez, S
2016-11-01
Heart failure was a public health problem for one million of French patients. Patients are particularly concerned in rehospitalisation for this chronic pathology. A specific healthcare network was created to take care of patients with heart failure directly at home. This healthcare network (named VISage) brings a specific and adapted monitoring in heart failure. The main of this study was to evaluate the impact of healthcare network in rehospitalisation rate for heart failure of patients. We conducted a retrospective cohort study with patients' hospital files of the CH Vienne. Patients who were included in our healthcare network (VISage) were screened. Primary endpoint was 30days, 6 months, and 1year rehospitalisation rate for heart failure before and after using healthcare network. One hundred and four patients with comorbidities were included between February 2009 and November 2015. A significant reduction of rehospitalisation rate for heart failure was observed before and after network: 0.65 (±0.52) vs. 0.17 (±0.43) 30days, 1.17 (±0.74) vs. 0.42 (±0.71) at 6 months and 1.35 (±0.95) vs. 0.47 (±0.74) at 1 year (P<0.0001). Results were significant for global rehospitalisation rate too. No significant differences were shown on hospital length of stay. Coordinated healthcare by a specific network at home for elderly is benefic for the rehospitalisation rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
The automated counting of beating rates in individual cultured heart cells.
Collins, G A; Dower, R; Walker, M J
1981-12-01
The effect of drugs on the beating rate of cultured heart cells can be monitored in a number of ways. The simultaneous automated measurement of beating rates of a number of cells allows drug effects to be rapidly quantified. A photoresistive detector placed on a television image of a cell, when coupled to operational amplifiers, gives binary signals that can be processed by a microprocessor. On this basis, we have devised a system that is capable of simultaneously monitoring the individual beating of six single cultured heart cells. A microprocessor automatically processes data obtained under different experimental conditions and records it in suitable descriptive formats such as dose-response curves and double reciprocal plots.
HYPNOTIZABILITY AND PAIN MODULATION: A Body-Mind Perspective.
Varanini, Maurizio; Balocchi, Rita; Carli, Giancarlo; Paoletti, Giulia; Santarcangelo, Enrica L
2018-01-01
The study investigated whether the cardiac activity and cognitive-emotional traits sustained by the behavioral inhibition/activation system (BIS/BAS) may contribute to hypnotizability-related pain modulation. Nociceptive stimulation (cold-pressor test) was administered to healthy participants with high (highs) and low (lows) hypnotizability in the presence and absence of suggestions for analgesia. Results showed that heart rate increased abruptly at the beginning of nociceptive stimulation in all participants. Then, only in highs heart rate decreased for the entire duration of hand immersion. During stimulation with suggestions of analgesia, pain threshold negatively correlated with heart rate. BIS/BAS activity partially accounted for the observed hypnotizability-related differences in the relation between cardiac interoception and pain experience.
Effects of active recovery on autonomic and haemodynamic responses after aerobic exercise.
Soares, Antonio H G; Oliveira, Tiago P; Cavalcante, Bruno R; Farah, Breno Q; Lima, Aluísio H R A; Cucato, Gabriel G; Cardoso, Crivaldo G; Ritti-Dias, Raphael M
2017-01-01
The aim of this study was to examine the effect of active recovery on autonomic and haemodynamic responses after exercise in healthy adults. Nineteen healthy young male individuals underwent two experimental sessions: exercise with active recovery (AR) and exercise with passive recovery (PR). The exercise sessions comprised three phases: warm-up (5 min), exercise phase (cycle ergometer, 30 min, intensity between 60 and 70% of the heart rate reserve) and recovery (5 min). In the AR, the subjects remained cycling in the recovery phase at intensity between 30% and 35% of heart rate reserve, while in the PR, the subjects stopped the exercise after finishing the exercise phase. Blood pressure and heart rate were measured before and over the 30 min after the interventions. There were no differences for systolic and diastolic blood pressures, heart rate and rate pressure product between active and passive recovery sessions. Also, all heart rate variability parameters changed similarly after exercise with passive or active recovery sessions. In summary, exercise with active recovery does not affect the autonomic and haemodynamic responses after moderate-intensity aerobic exercise in healthy young male individuals. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Perdue, Katherine L.; Edwards, Laura A.; Tager-Flusberg, Helen; Nelson, Charles A.
2017-01-01
We investigated heart rate (HR) in infants at 3, 6, 9, and 12 months of age, at high (HRA) and low (LRC) familial risk for ASD, to identify potential endophenotypes of ASD risk related to attentional responses. HR was extracted from functional near-infrared spectroscopy recordings while infants listened to speech stimuli. Longitudinal analysis…
ERIC Educational Resources Information Center
Elsner, Birgit; Pauen, Sabina; Jeschonek, Susanna
2006-01-01
This report investigates the relations between duration of examining and heart rate (HR) across several trials of an object-examination task. A total of N= 20 11-month-olds were familiarized with a sequence of 10 different exemplars from the same global category (animals or furniture) before they received an exemplar from the contrasting category…
Cognition Effects of Low-Grade Hypoxia
2016-07-01
oxygen con- tent and/or cerebral blood flow . Hypocapnia shifts the oxygen dissociation curve to the left, resulting in an increase in blood oxygen ...pressure chamber in a balanced design. Oxygen saturation, heart rate, and cognitive performance on seven different cognitive tasks were measured. In...addition, subjects indicated their symptoms from a 33-item subjective symptom survey. As designed, oxygen saturation decreased and heart rate increased
Randomised controlled trial of thiopental for intubation in neonates
Bhutada, A; Sahni, R; Rastogi, S; Wung, J
2000-01-01
AIMS—To determine the effects of premedication with thiopental on heart rate, blood pressure, and oxygen saturation during semi-elective nasotracheal intubation in neonates. METHODS—A randomised, placebo controlled, non-blinded study design was used to study 30 neonates (mean birthweight 3.27 kg) requiring semi-elective nasotracheal intubation. The babies were randomly allocated to receive either 6 mg/kg of thiopental (study group) or an equivalent volume of physiological saline (control group) one minute before the start of the procedure. Six infants were intubated primarily and 24 were changed from orotracheal to a nasotracheal tube. The electrocardiogram, arterial pressure wave, and transcutaneous oxygen saturation were recorded continuously 10 minutes before, during, and 20 minutes after intubation. Minute by minute measurements of heart rate, heart rate variability, mean blood pressure (MBP) and transcutaneous oxygen saturation (SpO2) were computed. The differences for all of these between the baseline measurements and those made during and after intubation were determined. Differences in the measurements made in the study and the control groups were compared using Student's t test. RESULTS—During intubation, heart rate increased to a greater degree (12.0 vs−0.5 beats per minute, p < 0.03) and MBP increased to a lesser degree (−2.9 vs 4.4 mm Hg; p < 0.002) in the infants who were premedicated with thiopental. After intubation only the changes in MBP differed significantly between the two groups (−3.8 vs 4.6 mm Hg; p < 0.001). There were no significant changes in the oxygen saturation between the two groups during or after intubation. The time taken for intubation was significantly shorter in the study group (p < 0.04). CONCLUSIONS—The heart rate and blood pressure of infants who are premedicated with thiopental are maintained nearer to baseline values than those of similar infants who receive no premedication. Whether this lessening of the acute drop in the heart rate and increase in blood pressure typically seen during intubation of unmedicated infants is associated with long term advantages to the infants remains to be determined. PMID:10634839
Cozza, Izabela Campos; Zanetta, Dirce Maria Trevisan; Fernandes, Frederico Leon Arrabal; da Rocha, Francisco Marcelo Monteiro; de Andre, Paulo Afonso; Garcia, Maria Lúcia Bueno; Paceli, Renato Batista; Prado, Gustavo Faibischew; Terra-Filho, Mario; do Nascimento Saldiva, Paulo Hilário; de Paula Santos, Ubiratan
2015-07-01
The effects of air pollution on health are associated with the amount of pollutants inhaled which depends on the environmental concentration and the inhaled air volume. It has not been clear whether statistical models of the relationship between heart rate and ventilation obtained using laboratory cardiopulmonary exercise test (CPET) can be applied to an external group to estimate ventilation. To develop and evaluate a model to estimate respiratory ventilation based on heart rate for inhaled load of pollutant assessment in field studies. Sixty non-smoking men; 43 public street workers (public street group) and 17 employees of the Forest Institute (park group) performed a maximum cardiopulmonary exercise test (CPET). Regression equation models were constructed with the heart rate and natural logarithmic of minute ventilation data obtained on CPET. Ten individuals were chosen randomly (public street group) and were used for external validation of the models (test group). All subjects also underwent heart rate register, and particulate matter (PM2.5) monitoring for a 24-hour period. For the public street group, the median difference between estimated and observed data was 0.5 (CI 95% -0.2 to 1.4) l/min and for the park group was 0.2 (CI 95% -0.2 to 1.2) l/min. In the test group, estimated values were smaller than the ones observed in the CPET, with a median difference of -2.4 (CI 95% -4.2 to -1.8) l/min. The mixed model estimated values suggest that this model is suitable for situations in which heart rate is around 120-140bpm. The mixed effect model is suitable for ventilation estimate, with good accuracy when applied to homogeneous groups, suggesting that, in this case, the model could be used in field studies to estimate ventilation. A small but significant difference in the median of external validation estimates was observed, suggesting that the applicability of the model to external groups needs further evaluation. Copyright © 2015 Elsevier B.V. All rights reserved.
Adlakha, Himanshu; Gupta, Ruchi; Hassan, Romana; Kern, Jeffrey H
2018-01-28
Vasovagal syncope is the most common cause of syncope in children and adults, accounting for 50-66% of unexplained syncope. There are no studies establishing the relationship between syncope, baseline heart rate, and blood pressure. To identify a possible association between baseline blood pressure and heart rate with syncope. We conducted a questionnaire-based chart review study. A questionnaire was distributed to the guardian of children between eight and 18 years of age who attended the Pediatric Ambulatory Care Clinic at Flushing Hospital Medical Center. Based on the responses in the questionnaire, subjects were classified either as cases (positive for syncope) or controls (negative for syncope). Children and adolescents with neurological, cardiac, or any medical condition that can cause syncopal episodes were excluded from the study. Data collected from the questionnaire included age, gender, ethnicity, medical history, family history of syncope, and the amount of salt used in food. Anthropometric and vital signs for the current visit (height, weight, BMI, blood pressure, and heart rate) and vital signs from two previous visits were collected from electronic medical records. The data was analyzed using t-test and chi-square test with Microsoft Excel software (Microsoft Office Standard, v. 14, Microsoft; 2010); p<0.05 was considered significant. A total of 197 subjects were included in this study. There were 18 cases and 179 controls. Of the cases, (4/18) 22.2% were more likely to have a systolic blood pressure lower than the 10th percentile for their gender, age, and height as compared with controls (7/179) 3.9%, p = 0.003. The subjects with a history of syncope were more likely to add salt to their food (p = 0.004). There were no significant differences between cases and controls for age, gender, ethnicity between cases and controls for systolic blood pressure. No significant difference was observed between the heart rates of cases and controls. Children and adolescents with syncope were more likely to have a systolic blood pressure lower than the 10th percentile, and there was no difference in the baseline heart rate. In addition, children with syncope were more likely to add salt to their food.
Zhou, F-J; Zhou, C-Y; Tian, Y-J; Xiao, A-J; Li, P-L; Wang, Y-H; Jia, J-W
2014-01-01
To analyze the expression of heart-fatty acid-binding protein (H-FABP), N-terminal pro-brain natriuretic peptide (NT-proBNP), and cTnI in children with congenital heart disease (CHD) and pneumonia, and evaluate its diagnostic value in heart failure (HF). The levels of serum H-FABP, NT-proBNP, and cardiac troponin 1 (cTnI) were measured by immunoassays in 22 children with CHD, pneumonia, and HF (group I), 25 children with CHD and pneumonia (group II), and 25 healthy children without CHD or pneumonia (control group). The concentration and positive rate of serum H-FABP, NT-proBNP, and cTnI were significantly higher in group I than those in group II. Compared to control group, these indexes were increased in both group I and group II. There were statistical significant differences in the positive rate of NT-proBNP and cTnI but not H-FABP between groups of patients with different classes of heart function. The levels of H-FABP, NT-proBNP, and cTnI were correlated with heart function, and can be used for the diagnosis of early-stage HF in children with CHD.
Changes in heart rate variability during the induction and decay of heat acclimation.
Flouris, Andreas D; Poirier, Martin P; Bravi, Andrea; Wright-Beatty, Heather E; Herry, Christophe; Seely, Andrew J; Kenny, Glen P
2014-10-01
We evaluated the changes in core temperature, heart rate, and heart rate variability (HRV) during the induction and decay of heat acclimation. Ten males (23 ± 3 years; 79.5 ± 3.5 kg; 15.2 ± 4.5 percent body fat; 51.13 ± 4.61 mLO(2)∙kg(-1)∙min(-1) peak oxygen uptake) underwent a 14-day heat acclimation protocol comprising of 90-min cycling at ~50 % peak oxygen uptake at 40 °C and ~20 % relative humidity. Core temperature, heart rate, and 102 HRV measures were recorded during a heat tolerance test conducted at baseline (day 0) and at the end of the induction (day 14) and decay (day 28) phases. Heat acclimation resulted in significantly reduced core temperature [rectal (χ (2) = 1298.14, p < 0.001); esophageal (χ (2) = 1069.88, p < 0.001)] and heart rate (χ (2) = 1230.17, p < 0.001). Following the decay phase, 26, 40, and 60 % of the heat acclimation-induced reductions in rectal temperature, esophageal temperature, and heart rate, respectively, were lost. Heat acclimation was accompanied by profound and broad changes in HRV: at the end of the induction phase, 75 of the 102 variability measures computed were significantly different (p < 0.001), compared to only 47 of the 102 at the end of the decay phase. Heat acclimation is accompanied by reduced core temperature, significant bradycardia, and marked alterations in HRV, which we interpret as being related to vagal dominance. The observed changes in core temperature persist for at least 2 weeks of non-exposure to heat, while the changes in heart rate and HRV decay faster and are only partly evident after 2 weeks of non-exposure to heat.
Li, Yingxin; Zhang, Xiaoxiao; Zhang, Chen; Zhang, Xiaoying; Li, Ying; Qi, Zhao; Szeto, Christopher; Tang, Mingxin; Peng, Yizhi; Molkentin, Jeffery D; Houser, Steven R; Xie, Mingxing; Chen, Xiongwen
2018-04-01
Cav3.1 T-type Ca 2+ channel current (I Ca-T ) contributes to heart rate genesis but is not known to contribute to heart rate regulation by the sympathetic/β-adrenergic system (SAS). We show that the loss of Cav3.1 makes the beating rates of the heart in vivo and perfused hearts ex vivo, as well as sinoatrial node cells, less sensitive to β-adrenergic stimulation; it also renders less conduction acceleration through the atrioventricular node by β-adrenergic stimulation. Increasing Cav3.1 in cardiomyocytes has the opposite effects. I Ca-T in sinoatrial nodal cells can be upregulated by β-adrenergic stimulation. The results of the present study add a new contribution to heart rate regulation by the SAS system and provide potential new mechanisms for the dysregulation of heart rate and conduction by the SAS in the heart. T-type Ca 2+ channel can be a target for heart disease treatments that aim to slow down the heart rate ABSTRACT: Cav3.1 (α 1G ) T-type Ca 2+ channel (TTCC) is expressed in mouse sinoatrial node cells (SANCs) and atrioventricular (AV) nodal cells and contributes to heart rate (HR) genesis and AV conduction. However, its role in HR regulation and AV conduction acceleration by the β-adrenergic system (SAS) is unclear. In the present study, L- (I Ca-L ) and T-type (I Ca-T ) Ca 2+ currents were recorded in SANCs from Cav3.1 transgenic (TG) and knockout (KO), and control mice. I Ca-T was absent in KO SANCs but enhanced in TG SANCs. In anaesthetized animals, different doses of isoproterenol (ISO) were infused via the jugular vein and the HR was recorded. The EC 50 of the HR response to ISO was lower in TG mice but higher in KO mice, and the maximal percentage of HR increase by ISO was greater in TG mice but less in KO mice. In Langendorff-perfused hearts, ISO increased HR and shortened PR intervals to a greater extent in TG but to a less extent in KO hearts. KO SANCs had significantly slower spontaneous beating rates than control SANCs before and after ISO; TG SANCs had similar basal beating rates as control SANCs probably as a result of decreased I Ca-L but a greater response to ISO than control SANCs. I Ca-T in SANCs was significantly increased by ISO. I Ca-T upregulation by β-adrenergic stimulation contributes to HR and conduction regulation by the SAS. TTCC can be a target for slowing the HR. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
Lass, Achim; Agarwal, Sanjiv; Sohal, Rajindar S.
2010-01-01
Rates of mitochondrial superoxide anion radical ( O2·¯) generation are known to be inversely correlated with the maximum life span potential of different mammalian species. The objective of this study was to understand the possible mechanism(s) underlying such variations in the rate of O2·¯ generation. The hypothesis that the relative amounts of the ubiquinones or coenzyme Q (CoQ) homologues, CoQ9 and CoQ10, are related with the rate of O2·¯ generation was tested. A comparison of nine different mammalian species, namely mouse, rat, guinea pig, rabbit, pig, goat, sheep, cow, and horse, which vary from 3.5 to 46 years in their maximum longevity, indicated that the rate of O2·¯ generation in cardiac submitochondrial particles (SMPs) was directly related to the relative amount of CoQ9 and inversely related to the amount of CoQ10, extractable from their cardiac mitochondria. To directly test the relationship between CoQ homologues and the rate of O2·¯ generation, rat heart SMPs, naturally containing mainly CoQ9 and cow heart SMPs, with high natural CoQ10 content, were chosen for depletion/reconstitution experiments. Repeated extractions of rat heart SMPs with pentane exponentially depleted both CoQ homologues while the corresponding rates of O2·¯ generation and oxygen consumption were lowered linearly. Reconstitution of both rat and cow heart SMPs with different amounts of CoQ9 or CoQ10 caused an initial increase in the rates of O2·¯ generation, followed by a plateau at high concentrations. Within the physiological range of CoQ concentrations, there were no differences in the rates of O2·¯ generation between SMPs reconstituted with CoQ9 or CoQ10. Only at concentrations that were considerably higher than the physiological level, the SMPs reconstituted with CoQ9 exhibited higher rates of O2·¯ generation than those obtained with CoQ10. These in vitro findings do not support the hypothesis that differences in the distribution of CoQ homologues are responsible for the variations in the rates of mitochondrial O2·¯ generation in different mammalian species. PMID:9235911
Quinn, T Alexander; Kohl, Peter
2016-12-01
Mechanical stimulation (MS) represents a readily available, non-invasive means of pacing the asystolic or bradycardic heart in patients, but benefits of MS at higher heart rates are unclear. Our aim was to assess the maximum rate and sustainability of excitation by MS vs. electrical stimulation (ES) in the isolated heart under normal physiological conditions. Trains of local MS or ES at rates exceeding intrinsic sinus rhythm (overdrive pacing; lowest pacing rates 2.5±0.5 Hz) were applied to the same mid-left ventricular free-wall site on the epicardium of Langendorff-perfused rabbit hearts. Stimulation rates were progressively increased, with a recovery period of normal sinus rhythm between each stimulation period. Trains of MS caused repeated focal ventricular excitation from the site of stimulation. The maximum rate at which MS achieved 1:1 capture was lower than during ES (4.2±0.2 vs. 5.9±0.2 Hz, respectively). At all overdrive pacing rates for which repetitive MS was possible, 1:1 capture was reversibly lost after a finite number of cycles, even though same-site capture by ES remained possible. The number of MS cycles until loss of capture decreased with rising stimulation rate. If interspersed with ES, the number of MS to failure of capture was lower than for MS only. In this study, we demonstrate that the maximum pacing rate at which MS can be sustained is lower than that for same-site ES in isolated heart, and that, in contrast to ES, the sustainability of successful 1:1 capture by MS is limited. The mechanism(s) of differences in MS vs. ES pacing ability, potentially important for emergency heart rhythm management, are currently unknown, thus warranting further investigation. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.
Quinn, T. Alexander; Kohl, Peter
2016-01-01
Aims Mechanical stimulation (MS) represents a readily available, non-invasive means of pacing the asystolic or bradycardic heart in patients, but benefits of MS at higher heart rates are unclear. Our aim was to assess the maximum rate and sustainability of excitation by MS vs. electrical stimulation (ES) in the isolated heart under normal physiological conditions. Methods and results Trains of local MS or ES at rates exceeding intrinsic sinus rhythm (overdrive pacing; lowest pacing rates 2.5±0.5 Hz) were applied to the same mid-left ventricular free-wall site on the epicardium of Langendorff-perfused rabbit hearts. Stimulation rates were progressively increased, with a recovery period of normal sinus rhythm between each stimulation period. Trains of MS caused repeated focal ventricular excitation from the site of stimulation. The maximum rate at which MS achieved 1:1 capture was lower than during ES (4.2±0.2 vs. 5.9±0.2 Hz, respectively). At all overdrive pacing rates for which repetitive MS was possible, 1:1 capture was reversibly lost after a finite number of cycles, even though same-site capture by ES remained possible. The number of MS cycles until loss of capture decreased with rising stimulation rate. If interspersed with ES, the number of MS to failure of capture was lower than for MS only. Conclusion In this study, we demonstrate that the maximum pacing rate at which MS can be sustained is lower than that for same-site ES in isolated heart, and that, in contrast to ES, the sustainability of successful 1:1 capture by MS is limited. The mechanism(s) of differences in MS vs. ES pacing ability, potentially important for emergency heart rhythm management, are currently unknown, thus warranting further investigation. PMID:28011835
Autonomic regulation in fetuses with Congenital Heart Disease
Siddiqui, Saira; Wilpers, Abigail; Myers, Michael; Nugent, J. David; Fifer, William P.; Williams, Ismée A.
2015-01-01
Background Exposure to antenatal stressors affects autonomic regulation in fetuses. Whether the presence of congenital heart disease (CHD) alters the developmental trajectory of autonomic regulation is not known. Aims/Study Design This prospective observational cohort study aimed to further characterize autonomic regulation in fetuses with CHD; specifically hypoplastic left heart syndrome (HLHS), transposition of the great arteries (TGA), and tetralogy of Fallot (TOF). Subjects From 11/2010 – 11/2012, 92 fetuses were enrolled: 41 controls and 51 with CHD consisting of 19 with HLHS, 12 with TGA, and 20 with TOF. Maternal abdominal fetal electrocardiogram (ECG) recordings were obtained at 3 gestational ages: 19-27 weeks (F1), 28-33 weeks (F2), and 34-38 weeks (F3). Outcome measures Fetal ECG was analyzed for mean heart rate along with 3 measures of autonomic variability of the fetal heart rate: interquartile range, standard deviation, and root mean square of the standard deviation of the heart rate (RMSSD), a measure of parasympathetic activity. Results During F1 and F2 periods, HLHS fetuses demonstrated significantly lower mean HR than controls (p<0.05). Heart rate variability at F3, as measured by standard deviation, interquartile range, and RMSSD was lower in HLHS than controls (p<0.05). Other CHD subgroups showed a similar, though non-significant trend towards lower variability. Conclusions Autonomic regulation in CHD fetuses differs from controls with HLHS fetuses most markedly affected. PMID:25662702
Autonomic regulation in fetuses with congenital heart disease.
Siddiqui, Saira; Wilpers, Abigail; Myers, Michael; Nugent, J David; Fifer, William P; Williams, Ismée A
2015-03-01
Exposure to antenatal stressors affects autonomic regulation in fetuses. Whether the presence of congenital heart disease (CHD) alters the developmental trajectory of autonomic regulation is not known. This prospective observational cohort study aimed to further characterize autonomic regulation in fetuses with CHD; specifically hypoplastic left heart syndrome (HLHS), transposition of the great arteries (TGA), and tetralogy of Fallot (TOF). From 11/2010 to 11/2012, 92 fetuses were enrolled: 41 controls and 51 with CHD consisting of 19 with HLHS, 12 with TGA, and 20 with TOF. Maternal abdominal fetal electrocardiogram (ECG) recordings were obtained at 3 gestational ages: 19-27 weeks (F1), 28-33 weeks (F2), and 34-38 weeks (F3). Fetal ECG was analyzed for mean heart rate along with 3 measures of autonomic variability of the fetal heart rate: interquartile range, standard deviation, and root mean square of the standard deviation of the heart rate (RMSSD), a measure of parasympathetic activity. During F1 and F2 periods, HLHS fetuses demonstrated significantly lower mean HR than controls (p<0.05). Heart rate variability at F3, as measured by standard deviation, interquartile range, and RMSSD was lower in HLHS than controls (p<0.05). Other CHD subgroups showed a similar, though non-significant trend towards lower variability. Autonomic regulation in CHD fetuses differs from controls, with HLHS fetuses most markedly affected. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lessons from the Heart: Individualizing Physical Education with Heart Rate Monitors.
ERIC Educational Resources Information Center
Kirkpatrick, Beth; Birnbaum, Burton H.
Learning about the relationship between heart rate and physical activity is an important aspect of fitness education. Use of a heart rate monitor (HRM) helps a student to understand how stretching and large muscle movements gradually increase the heart rate and blood flow, and enables students to measure their exercise heart rates and set goals…
An adaptive Kalman filter technique for context-aware heart rate monitoring.
Xu, Min; Goldfain, Albert; Dellostritto, Jim; Iyengar, Satish
2012-01-01
Traditional physiological monitoring systems convert a person's vital sign waveforms, such as heart rate, respiration rate and blood pressure, into meaningful information by comparing the instant reading with a preset threshold or a baseline without considering the contextual information of the person. It would be beneficial to incorporate the contextual data such as activity status of the person to the physiological data in order to obtain a more accurate representation of a person's physiological status. In this paper, we proposed an algorithm based on adaptive Kalman filter that describes the heart rate response with respect to different activity levels. It is towards our final goal of intelligent detection of any abnormality in the person's vital signs. Experimental results are provided to demonstrate the feasibility of the algorithm.
van Gils, Lennart; Tchetche, Didier; Lhermusier, Thibault; Abawi, Masieh; Dumonteil, Nicolas; Rodriguez Olivares, Ramón; Molina-Martin de Nicolas, Javier; Stella, Pieter R; Carrié, Didier; De Jaegere, Peter P; Van Mieghem, Nicolas M
2017-03-03
Right bundle branch block is an established predictor for new conduction disturbances and need for a permanent pacemaker (PPM) after transcatheter aortic valve replacement. The aim of the study was to evaluate the absolute rates of transcatheter aortic valve replacement related PPM implantations in patients with pre-existent right bundle branch block and categorize for different transcatheter heart valves. We pooled data on 306 transcatheter aortic valve replacement patients from 4 high-volume centers in Europe and selected those with right bundle branch block at baseline without a previously implanted PPM. Logistic regression was used to evaluate whether PPM rate differed among transcatheter heart valves after adjustment for confounders. Mean age was 83±7 years and 63% were male. Median Society of Thoracic Surgeons score was 6.3 (interquartile range, 4.1-10.2). The following transcatheter valve designs were used: Medtronic CoreValve (n=130; Medtronic, Minneapolis, MN); Edwards Sapien XT (ES-XT; n=124) and Edwards Sapien 3 (ES-3; n=32; Edwards Lifesciences, Irvine, CA); and Boston Scientific Lotus (n=20; Boston Scientific Corporation, Marlborough, MA). Overall permanent pacemaker implantation rate post-transcatheter aortic valve replacement was 41%, and per valve design: 75% with Lotus, 46% with CoreValve, 32% with ES-XT, and 34% with ES-3. The indication for PPM implantation was total atrioventricular block in 98% of the cases. Lotus was associated with a higher PPM rate than all other valves. PPM rate did not differ between ES-XT and ES-3. Ventricular paced rhythm at 30-day and 1-year follow-up was present in 81% at 89%, respectively. Right bundle branch block at baseline is associated with a high incidence of PPM implantation for all transcatheter heart valves. PPM rate was highest for Lotus and lowest for ES-XT and ES-3. Pacemaker dependency remained high during follow-up. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Effect of Different Phases of Menstrual Cycle on Heart Rate Variability (HRV).
Brar, Tejinder Kaur; Singh, K D; Kumar, Avnish
2015-10-01
Heart Rate Variability (HRV), which is a measure of the cardiac autonomic tone, displays physiological changes throughout the menstrual cycle. The functions of the ANS in various phases of the menstrual cycle were examined in some studies. The aim of our study was to observe the effect of menstrual cycle on cardiac autonomic function parameters in healthy females. A cross-sectional (observational) study was conducted on 50 healthy females, in the age group of 18-25 years. Heart Rate Variability (HRV) was recorded by Physio Pac (PC-2004). The data consisted of Time Domain Analysis and Frequency Domain Analysis in menstrual, proliferative and secretory phase of menstrual cycle. Data collected was analysed statistically using student's pair t-test. The difference in mean heart rate, LF power%, LFnu and HFnu in menstrual and proliferative phase was found to be statistically significant. The difference in mean RR, Mean HR, RMSSD (the square root of the mean of the squares of the successive differences between adjacent NNs.), NN50 (the number of pairs of successive NNs that differ by more than 50 ms), pNN50 (the proportion of NN50 divided by total number of NNs.), VLF (very low frequency) power, LF (low frequency) power, LF power%, HF power %, LF/HF ratio, LFnu and HFnu was found to be statistically significant in proliferative and secretory phase. The difference in Mean RR, Mean HR, LFnu and HFnu was found to be statistically significant in secretory and menstrual phases. From the study it can be concluded that sympathetic nervous activity in secretory phase is greater than in the proliferative phase, whereas parasympathetic nervous activity is predominant in proliferative phase.
Effect of Different Phases of Menstrual Cycle on Heart Rate Variability (HRV)
Singh, K. D.; Kumar, Avnish
2015-01-01
Background Heart Rate Variability (HRV), which is a measure of the cardiac autonomic tone, displays physiological changes throughout the menstrual cycle. The functions of the ANS in various phases of the menstrual cycle were examined in some studies. Aims and Objectives The aim of our study was to observe the effect of menstrual cycle on cardiac autonomic function parameters in healthy females. Materials and Methods A cross-sectional (observational) study was conducted on 50 healthy females, in the age group of 18-25 years. Heart Rate Variability (HRV) was recorded by Physio Pac (PC-2004). The data consisted of Time Domain Analysis and Frequency Domain Analysis in menstrual, proliferative and secretory phase of menstrual cycle. Data collected was analysed statistically using student’s pair t-test. Results The difference in mean heart rate, LF power%, LFnu and HFnu in menstrual and proliferative phase was found to be statistically significant. The difference in mean RR, Mean HR, RMSSD (the square root of the mean of the squares of the successive differences between adjacent NNs.), NN50 (the number of pairs of successive NNs that differ by more than 50 ms), pNN50 (the proportion of NN50 divided by total number of NNs.), VLF (very low frequency) power, LF (low frequency) power, LF power%, HF power %, LF/HF ratio, LFnu and HFnu was found to be statistically significant in proliferative and secretory phase. The difference in Mean RR, Mean HR, LFnu and HFnu was found to be statistically significant in secretory and menstrual phases. Conclusion From the study it can be concluded that sympathetic nervous activity in secretory phase is greater than in the proliferative phase, whereas parasympathetic nervous activity is predominant in proliferative phase. PMID:26557512
Playing a violent television game affects heart rate variability.
Ivarsson, Malena; Anderson, Martin; Akerstedt, Torbjörn; Lindblad, Frank
2009-01-01
To investigate how playing a violent/nonviolent television game during the evening affects sympathetic and parasympathetic reactions during and after playing as well as sleep quality during the night after playing. In total, 19 boys, 12-15 years of age, played television games on two occasions in their homes and participated once without gaming. Heart rate, heart rate variability (HRV) and physical activity were measured during gaming/participating and the night to follow using a portable combined heart rate and movement sensor. A sleep diary and questionnaires about gaming experiences and session-specific experiences were filled in. Criteria for Selection of Games: Violent game involves/rewards direct physical violence (no handguns) against another person, and nonviolent game involves/rewards no violence; same game design ('third-person game'); conducted in the same manner; no differences concerning motor activity; similar sound and light effects; no sexual content, violence against women or racial overtones. During violent (vs. nonviolent) gaming, there was significantly higher activity of the very low frequency component of the HRV and total power. During the night after playing, very low frequency, low frequency and high frequency components were significantly higher during the violent (vs. nonviolent) condition, just as total power. There were no significant differences between the three conditions (violent/nonviolent/no gaming) with respect to an index reflecting subjectively perceived sleep difficulties. Nor was there any difference between violent and nonviolent condition for any single sleep item. Violent gaming induces different autonomic responses in boys compared to nonviolent gaming--during playing and during the following night--suggesting different emotional responses. Subjectively perceived sleep quality is not influenced after a single gaming experience. Future studies should address the development of the autonomic balance after gaming over longer time than a night, physiological adaptation to frequent gaming and potential gender differences.
Salvi, Paolo; Palombo, Carlo; Salvi, Giovanni Matteo; Labat, Carlos; Parati, Gianfranco; Benetos, Athanase
2013-12-01
Several studies showed a positive association between heart rate and pulse wave velocity, a sensitive marker of arterial stiffness. However, no study involving a large population has specifically addressed the dependence of pulse wave velocity on different components of the cardiac cycle. The aim of this study was to explore in subjects of different age the link between pulse wave velocity with heart period (the reciprocal of heart rate) and the temporal components of the cardiac cycle such as left ventricular ejection time and diastolic time. Carotid-femoral pulse wave velocity was assessed in 3,020 untreated subjects (1,107 men). Heart period, left ventricular ejection time, diastolic time, and early-systolic dP/dt were determined by carotid pulse wave analysis with high-fidelity applanation tonometry. An inverse association was found between pulse wave velocity and left ventricular ejection time at all ages (<25 years, r(2) = 0.043; 25-44 years, r(2) = 0.103; 45-64 years, r(2) = 0.079; 65-84 years, r(2) = 0.044; ≥ 85 years, r(2) = 0.022; P < 0.0001 for all). A significant (P < 0.0001) negative but always weaker correlation between pulse wave velocity and heart period was also found, with the exception of the youngest subjects (P = 0.20). A significant positive correlation was also found between pulse wave velocity and dP/dt (P < 0.0001). With multiple stepwise regression analysis, left ventricular ejection time and dP/dt remained the only determinant of pulse wave velocity at all ages, whereas the contribution of heart period no longer became significant. Our data demonstrate that pulse wave velocity is more closely related to left ventricular systolic function than to heart period. This may have methodological and pathophysiological implications.
Heart rate monitoring mobile applications.
Chaudhry, Beenish M
2016-01-01
Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone's camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, 'Unique Heart Rate Monitor', you can also maintain your heart rate history for personal reflection and sharing with a provider.
Cooling, J; Blundell, J
1998-07-01
To investigate physiological differences between habitual high-fat (HF) and low-fat (LF) consumers, which could influence the balance between energy expenditure and energy intake, and the potential for weight gain. 16 young, lean males (eight HF and eight LF consumers; % energy from fat 44.3 and 32.0, respectively). Habitual dietary variables (from FFQ), body mass index (BMI), body fat % (measured by impedance), resting metabolic rate (RMR) (indirect calorimetry), substrate oxidation and basal heart rate, postprandial thermogenesis and heart rate in response to a high-fat (low carbohydrate (CHO)) and high-CHO (low fat) challenge. HF and LF (selected for their intake of fat) did not differ significantly in BMI or % body fat. HF had a significantly higher RMR (1624 vs 1455 kcal/d) and basal heart rate (66 vs 57 bpm) than LF. Differences in oxygen utilisation and heart rate were maintained over a 180 min period, following the high-fat and high-CHO challenge meals. HF had a significantly lower resting respiratory quotient (RQ) than LF and the differences in average RQ were significant over the 180 min examination period. HF had a significantly lower RQ response to the high fat (low CHO) than to the high CHO (low fat) challenge; this effect was not observed in LF. HF had higher total energy intake than LF and a higher absolute (but not %) intake of protein. Significant differences in basal energy expenditure and fat oxidation between habitual HF and LF consumers have been observed. The contributions of energy intake and protein intake (g not %) remain to be determined. In this particular group of subjects (young adult males) a high energy intake characterised by a large fat component is associated with metabolic adaptations which could offset the weight inducing properties of a high-fat diet. These physiological differences may be important when considering the relationship between dietary-fat and obesity.
Rubik, Beverly
2017-01-01
This study investigated whether short-term exposure to a passive online software application of purported subtle energy technology would affect heart rate variability (HRV) and associated autonomic nervous system measures. This was a randomized, double-blinded, sham-controlled clinical trial (RCT). The study took place in a nonprofit laboratory in Emeryville, California. Twenty healthy, nonsmoking subjects (16 females), aged 40-75 years, participated. Quantum Code Technology ™ (QCT), a purported subtle energy technology, was delivered through a passive software application (Heart+ App) on a smartphone placed <1 m from subjects who were seated and reading a catalog. HRV was measured for 5 min in triplicate for each condition via finger plethysmography using a Food and Drug Administration medically approved HRV measurement device. Measurements were made at baseline and 35 min following exposure to the software applications. The following parameters were calculated and analyzed: heart rate, total power, standard deviation node-to-node, root mean square sequential difference, low frequency to high frequency ratio (LF/HF), low frequency (LF), and high frequency (HF). Paired samples t-tests showed that for the Heart+ App, mean LF/HF decreased (p = 9.5 × 10 -4 ), while mean LF decreased in a trend (p = 0.06), indicating reduced sympathetic dominance. Root mean square sequential difference increased for the Heart+ App, showing a possible trend (p = 0.09). Post-pre differences in LF/HF for sham compared with the Heart+ App were also significant (p < 0.008) by independent t-test, indicating clinical relevance. Significant beneficial changes in mean LF/HF, along with possible trends in mean LF and root mean square sequential difference, were observed in subjects following 35 min exposure to the Heart+ App that was working in the background on an active smartphone untouched by the subjects. This may be the first RCT to show that specific frequencies of a purported non-Hertzian type of subtle energy conveyed by software applications broadcast from personal electronic devices can be bioactive and beneficially impact autonomic nervous system balance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marino, Kady B.; Hoover-Miller, Anne; Conlon, Suzanne
This study quantified the Hg levels in the liver (n=98) and heart (n=43) tissues of Harbor Seals (Phoca vitulina) (n=102) harvested from Prince William Sound and Kodiak Island Alaska. Mercury tissue dry weight (dw) concentrations in the liver ranged from 1.7 to 393 ppm dw, and in the heart from 0.19 to 4.99 ppm dw. Results of this study indicate liver and heart tissues' Hg ppm dw concentrations significantly increase with age. Male Harbor Seals bioaccumulated Hg in both their liver and heart tissues at a significantly faster rate than females. The liver Hg bioaccumulation rates between the harvest locationsmore » Kodiak Island and Prince William Sound were not found to be significantly different. On adsorption Hg is transported throughout the Harbor Seal's body with the partition coefficient higher for the liver than the heart. No significant differences in the bio-distribution (liver:heart Hg ppm dw ratios (n=38)) values were found with respect to either age, sex or geographic harvest location. In this study the age at which Hg liver and heart bioaccumulation levels become significantly distinct in male and female Harbor Seals were identified through a Tukey's analysis. Of notably concern to human health was a male Harbor Seal's liver tissue harvested from Kodiak Island region. Mercury accumulation in this sample tissue was determined through a Q-test to be an outlier, having far higher Hg concentrarion (liver 392 Hg ppm dw) than the general population sampled. - Highlights: Black-Right-Pointing-Pointer Mercury accumulation in the liver and heart of seals exceed food safety guidelines. Black-Right-Pointing-Pointer Accumulation rate is greater in males than females with age. Black-Right-Pointing-Pointer Liver mercury accumulation is greater than in the heart tissues. Black-Right-Pointing-Pointer Mercury determination by USA EPA Method 7473 using thermal decomposition.« less
A comparison of heart rate responses in racquet games.
Docherty, D.
1982-01-01
The present study investigated the heart rate response to playing tennis with special reference to the skill levels and ages of the participants. Data obtained in a similar manner during earlier studies of badminton and squash players were compared with that obtained during tennis. The number of rallies, mean rally time and actual playing time in 30 minutes of play was also compared for the different skill levels and sports. Results showed that playing tennis raised the players' heart rates to 68-70% of their predicted maximum heart rate (PMHR). Playing squash and badminton could raise heart rates to 80-85% of the players' PMHR which was significantly higher than the values obtained for tennis. The actual skill level of the participants within their chosen sport did not have a significant effect in predicting the physical demands of squash or tennis but was important in predicting the heart rate response of badminton players. The more skillful the badminton player the greater the cardiac response as a result of game play. Analysis of time spent in actual play revealed that tennis players were involved in play for only five of the thirty minutes of game play, compared to 15 and 10 min respectively for squash and badminton. Skill level within each sport was only a significant factor in predicting length of play for squash players in which the medium and highly skilled groups played significantly longer than those of a lower level of skill. Images p96-a PMID:7104564
Prahm, Kira P.; Witting, Nanna; Vissing, John
2014-01-01
Objective The 6-minute walk test is widely used to assess functional status in neurological disorders. However, the test is subject to great inter-test variability due to fluctuating motivation, fatigue and learning effects. We investigated whether inter-test variability of the 6MWT can be reduced by heart rate correction. Methods Sixteen patients with neuromuscular diseases, including Facioscapulohumeral muscular dystrophy, Limb-girdle muscular dystrophy, Charcot-Marie-Tooths, Dystrophia Myotonica and Congenital Myopathy and 12 healthy subjects were studied. Patients were excluded if they had cardiac arrhythmias, if they received drug treatment for hypertension or any other medical conditions that could interfere with the interpretation of the heart rate and walking capability. All completed three 6-minute walk tests on three different test-days. Heart rate was measured continuously. Results Successive standard 6-minute walk tests showed considerable learning effects between Tests 1 and 2 (4.9%; P = 0.026), and Tests 2 and 3 (4.5%; P = 0.020) in patients. The same was seen in controls between Tests 1 and 2 (8.1%; P = 0.039)). Heart rate correction abolished this learning effect. Conclusion A modified 6-minute walk test, by correcting walking distance with average heart rate during walking, decreases the variability among repeated 6-minute walk tests, and should be considered as an alternative outcome measure to the standard 6-minute walk test in future clinical follow-up and treatment trials. PMID:25479403
Crew workload in JASDF C-1 transport flights: I. Change in heart rate and salivary cortisol.
Kakimoto, Y; Nakamura, A; Tarui, H; Nagasawa, Y; Yagura, S
1988-06-01
The physiological responses of heart rate and salivary cortisol for six paired captains and co-pilots during JASDF scheduled transport flights were compared to assess crew workload. The relative change of both responses showed similar patterns and were influenced significantly by whether pilots were controlling the aircraft. Moreover, differences in flying experience and responsibility of captains and co-pilots influenced the two physiological responses; heart rate and salivary cortisol measures increased more for both captains and co-pilots while they were in control of the aircraft than when they were not. Compared to captains, co-pilots showed much higher activation and variability in relative change of heart rate and salivary cortisol between periods of controlling and non-controlling the aircraft. On the other hand, captains showed relatively constant responses comparing aircraft controlling and non-controlling periods, especially in the cruise phase of flight. Salivary cortisol may be a useful, non-invasive method of assess crew workload.
Cardiorespiratory responses to orthostasis and the effects of propranolol
NASA Technical Reports Server (NTRS)
Loeppky, J. A.
1975-01-01
Cardiac output and gas exchange were determined serially using the single-breath method of Kim et al. before, during, and after orthostasis on six subjects after beta-adrenergic blockage and in duplicate controls. In the latter, heart rate increased and pulse pressure dropped immediately on tilting to 60 deg and remained stable while cardiac output and stroke volume declined gradually over 21 min upright. On propranolol, heart rate was 10 bpm lower supine and 20 bpm less at 60 deg but cardiac output was only slightly lower before and following tilt-up. However, after 15 min upright, stroke volume and cardiac output recovered on propranolol exceeding the controls after 21 min without change in heart rate. Returning to supine, heart rate dropped in all tests with a transitory increase in stroke volume, cardiac output and arteriovenous O2 difference. At the same time, apparent O2 uptake increased temporarily, reflecting the return of pooled venous blood to the lungs. Orthostatic tolerance did not appear to be affected by beta-adrenergic blockade.
De Rubeis, Jannika; Sütterlin, Stefan; Lange, Diane; Pawelzik, Markus; van Randenborgh, Annette; Victor, Daniela; Vögele, Claus
2016-01-01
Depression is assumed to be both a risk factor for rejection and a result of it, and as such constitutes an important factor in rejection research. Attachment theory has been applied to understand psychological disorders, such as depression, and can explain individual differences in responses to rejection. Research on autonomic nervous system activity to rejection experiences has been contradictory, with opposing strings of argumentation (activating vs. numbing). We investigated autonomic nervous system-mediated peripheral physiological responses (heart rate) to experimentally manipulated ostracism (Cyberball) in 97 depressed patients with organized (n = 52) and disorganized attachment status (n = 45). Controlling for baseline mean heart rate levels, depressed patients with disorganized attachment status responded to ostracism with significantly higher increases in heart rate than depressed patients with organized attachment status (p = .029; ηp2 = .051). These results suggest that attachment status may be a useful indicator of autonomic responses to perceived social threat, which in turn may affect the therapeutic process and the patient-therapist relationship. PMID:26943924
The effect of a scalp massage on stress hormone, blood pressure, and heart rate of healthy female
Kim, In-Hong; Kim, Tae-Young; Ko, Young-Wan
2016-01-01
[Purpose] A scalp massage was conducted on female office workers divided into a 15 minute group and 25 minute group and its effect on stress hormone, blood pressure and heart rate was analyzed in order to provide a theoretical rationale to apply scalp massage as stress therapy. [Subjects and Methods] A scalp massage was applied to 34 female office workers twice a week for a total of 10 weeks; the subjects were classified into 15 min., 25 min. and control groups, and their stress hormone levels, blood pressure and heart rate were evaluated. [Results] Significant differences in norepinephrine, cortisol and blood pressure (SBP & DBP) were found in terms of interaction by time interval and between groups. [Conclusion] As a result of applying scalp massage to female office workers for 15 and 25 minutes, positive effects were observed on stress hormone, blood pressure and heart rate. Therefore, scalp massage can be used for stress control with no spatial or time limit. PMID:27821918
The effect of a scalp massage on stress hormone, blood pressure, and heart rate of healthy female.
Kim, In-Hong; Kim, Tae-Young; Ko, Young-Wan
2016-10-01
[Purpose] A scalp massage was conducted on female office workers divided into a 15 minute group and 25 minute group and its effect on stress hormone, blood pressure and heart rate was analyzed in order to provide a theoretical rationale to apply scalp massage as stress therapy. [Subjects and Methods] A scalp massage was applied to 34 female office workers twice a week for a total of 10 weeks; the subjects were classified into 15 min., 25 min. and control groups, and their stress hormone levels, blood pressure and heart rate were evaluated. [Results] Significant differences in norepinephrine, cortisol and blood pressure (SBP & DBP) were found in terms of interaction by time interval and between groups. [Conclusion] As a result of applying scalp massage to female office workers for 15 and 25 minutes, positive effects were observed on stress hormone, blood pressure and heart rate. Therefore, scalp massage can be used for stress control with no spatial or time limit.
[Assessment of medical management of heart failure at National Hospital Blaise COMPAORE].
Kambiré, Y; Konaté, L; Diallo, I; Millogo, G R C; Kologo, K J; Tougouma, J B; Samadoulougou, A K; Zabsonré, P
2018-05-09
The aim of this study was to assess the quality of medical management of heart failure at the National Hospital Blaise Compaoré according to the international guidelines. A retrospective study was performed including consecutive patients admitted for heart failure documented sonographically from October 2012 to March 2015 in the Medicine and Medical Specialties Department of National Hospital Blaise Compaore with a minimum follow-up of six weeks. Data analysis was made by the SPSS 20.0 software. Eighty-four patients, mean age of 57.61±18.24 years, were included. It was an acute heart failure in 84.5% of patients with systolic left ventricular function impaired (77.4%). The rate of prescription of different drugs in heart failure any type was 88.1% for loop diuretics; 77.1% for angiotensin-converting enzyme inhibitors/angiotensin receptor blockers and 65.5% for betablockers. In patients with systolic dysfunction, 84.62% of patients were received the combination of angiotensin-converting enzyme inhibitors/angiotensin receptor blockers and 75.38% for betablockers. Exercise rehabilitation was undergoing in 10.7% of patients. The death rate was 16.7% and hospital readmission rate of 16.7%. The prescription rate of major heart failure drugs is satisfactory. Cardiac rehabilitation should be developed. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Music close to one's heart: heart rate variability with music, diagnostic with e-bra and smartphone
NASA Astrophysics Data System (ADS)
Hegde, Shantala; Kumar, Prashanth S.; Rai, Pratyush; Mathur, Gyanesh N.; Varadan, Vijay K.
2012-04-01
Music is a powerful elicitor of emotions. Emotions evoked by music, through autonomic correlates have been shown to cause significant modulation of parameters like heart rate and blood pressure. Consequently, Heart Rate Variability (HRV) analysis can be a powerful tool to explore evidence based therapeutic functions of music and conduct empirical studies on effect of musical emotion on heart function. However, there are limitations with current studies. HRV analysis has produced variable results to different emotions evoked via music, owing to variability in the methodology and the nature of music chosen. Therefore, a pragmatic understanding of HRV correlates of musical emotion in individuals listening to specifically chosen music whilst carrying out day to day routine activities is needed. In the present study, we aim to study HRV as a single case study, using an e-bra with nano-sensors to record heart rate in real time. The e-bra developed previously, has several salient features that make it conducive for this study- fully integrated garment, dry electrodes for easy use and unrestricted mobility. The study considers two experimental conditions:- First, HRV will be recorded when there is no music in the background and second, when music chosen by the researcher and by the subject is playing in the background.
Tactical swimming activity and heart rate aspects of youth water polo game.
Lupo, Corrado; Capranica, Laura; Cugliari, Giovanni; Gomez, Miguel A; Tessitore, Antonio
2016-09-01
Although physical demands could differently occur during particular phases of the youth water polo game, at present, literature lacks of time-motion and heart rate data referred to specific tactical situation. Therefore, the present study aimed to analyze a youth water polo game, specifying heart rate, and swimming activity aspects in relation to game situations. Twenty-six youth male players (15.6±0.5 years old) voluntary played a friendly game, which was tactically analyzed (offensive and defensive Even and Counterattack situation, and Power-play, Inferiority and Game Breaks) using notational analysis procedures. Successively, the heart rate (aerobic, anaerobic) and time motion (horizontal, vertical, and duel swimming patterns, with and without ball possession, backstroke) analyses were applied only to six (3 for team) players because they performed at list half of the total game duration. The tactical scenarios were mainly characterized by offensive (33%) and defensive (33%) even possessions, and game breaks (23%). No effect emerged between situations in terms of heart rate distribution, because it principally resulted as aerobic (range: 58-97%). The swimming activity analysis mainly showed differences (P≤0.05) between offensive counterattack and power-play in terms of distance (1 min of game, single pattern), time duration (1 min of game), and speed (single pattern) related to the horizontal activity. Repeated high intensity activities were performed 3.0±2.8 (range: 1-7) during the game. The findings of the present study provide important information for the planning of youth water polo training, with specific reference to playing situations.
Comparison of Ventilatory Measures and 20 km Time Trial Performance.
Peveler, Willard W; Shew, Brandy; Johnson, Samantha; Sanders, Gabe; Kollock, Roger
2017-01-01
Performance threshold measures are used to predict cycling performance. Previous research has focused on long time trials (≥ 40 km) using power at ventilatory threshold and respiratory threshold to estimate time trial performance. As intensity greatly differs during shorter time trails applying findings from longer time trials may not be appropriate. The use of heart rate measures to determine 20 km time trial performance has yet to be examined. The purpose of this study was to determine the effectiveness of heart rate measures at ventilatory threshold (VE/VO 2 Plotted and VT determined by software) and respiratory threshold (RER of 0.95, 1.00, and 1.05) to predict 20 km time trial performance. Eighteen cyclists completed a VO 2max protocol and two 20 km time trials. Average heart rates from 20 km time trials were compared with heart rates from performance threshold measures (VT plotted, VT software, and an RER at 0.95, 1.00, and 1.05) using repeated measures ANOVA. Significance was set a priori at P ≤ 0.05. The only measure not found to be significantly different in relation to time trial performance was HR at an RER of 1.00 (166.61±12.70 bpm vs. 165.89 ± 9.56 bpm, p = .671). VT plotting and VT determined by software were found to underestimate time trial performance by 3% and 8% respectively. From these findings it is recommended to use heart rate at a RER of 1.00 in order to determine 20 km time trial intensity.
Best anesthetics for assessing left ventricular systolic function by echocardiography in mice
Pachon, Ronald E.; Scharf, Bruce A.; Vatner, Dorothy E.
2015-01-01
Our review of the literature of the major cardiovascular journals for the past three years showed that for all studies using anesthesia for mouse echocardiography, the predominant anesthetic was isoflurane, which was used in 76% of the studies. The goal of this investigation was to determine if isoflurane is indeed the best anesthetic. Accordingly, we compared isoflurane with 2,2,2-tribromoethanol (Avertin), ketamine-xylazine, and ketamine on different days in the same 14 mice, also studied in the conscious state without anesthesia. A randomized crossover study design was employed to compare the effects on left ventricular (LV) systolic function and heart rate of the four different anesthetic agents assessed by transthoracic echocardiography. As expected, each anesthetic depressed LV ejection fraction and heart rate when compared with values in conscious mice. Surprisingly, isoflurane was not the best, but actually second to last in maintaining normal LV function and heart rate. The anesthetic with the least effect on LV function and heart rate was ketamine alone at a dose of 150 mg/kg, followed by Avertin at 290 mg/kg, isoflurane at 3% induction and 1 to 2% maintenance, and lastly ketamine-xylazine at 100 and 10 mg/kg, respectively. In summary, these results indicate that ketamine alone exerts the least depressant effects on LV function and heart rate, with Avertin second, suggesting that these anesthetics should be used when it is not feasible to study the animals in the conscious state as opposed to the most commonly used anesthetic, isoflurane. PMID:25862835
Best anesthetics for assessing left ventricular systolic function by echocardiography in mice.
Pachon, Ronald E; Scharf, Bruce A; Vatner, Dorothy E; Vatner, Stephen F
2015-06-15
Our review of the literature of the major cardiovascular journals for the past three years showed that for all studies using anesthesia for mouse echocardiography, the predominant anesthetic was isoflurane, which was used in 76% of the studies. The goal of this investigation was to determine if isoflurane is indeed the best anesthetic. Accordingly, we compared isoflurane with 2,2,2-tribromoethanol (Avertin), ketamine-xylazine, and ketamine on different days in the same 14 mice, also studied in the conscious state without anesthesia. A randomized crossover study design was employed to compare the effects on left ventricular (LV) systolic function and heart rate of the four different anesthetic agents assessed by transthoracic echocardiography. As expected, each anesthetic depressed LV ejection fraction and heart rate when compared with values in conscious mice. Surprisingly, isoflurane was not the best, but actually second to last in maintaining normal LV function and heart rate. The anesthetic with the least effect on LV function and heart rate was ketamine alone at a dose of 150 mg/kg, followed by Avertin at 290 mg/kg, isoflurane at 3% induction and 1 to 2% maintenance, and lastly ketamine-xylazine at 100 and 10 mg/kg, respectively. In summary, these results indicate that ketamine alone exerts the least depressant effects on LV function and heart rate, with Avertin second, suggesting that these anesthetics should be used when it is not feasible to study the animals in the conscious state as opposed to the most commonly used anesthetic, isoflurane. Copyright © 2015 the American Physiological Society.
Tagliarolo, Morgana; McQuaid, Christopher D.
2016-01-01
Attempts to predict the response of species to long-term environmental change are generally based on extrapolations from laboratory experiments that inevitably simplify the complex interacting effects that occur in the field. We recorded heart rates of two genetic lineages of the brown mussel Perna perna over a full tidal cycle in-situ at two different sites in order to evaluate the cardiac responses of the two genetic lineages present on the South African coast to temperature and the immersion/emersion cycle. “Robomussel” temperature loggers were used to monitor thermal conditions at the two sites over one year. Comparison with live animals showed that robomussels provided a good estimate of mussel body temperatures. A significant difference in estimated body temperatures was observed between the sites and the results showed that, under natural conditions, temperatures regularly approach or exceed the thermal limits of P. perna identified in the laboratory. The two P. perna lineages showed similar tidal and diel patterns of heart rate, with higher cardiac activity during daytime immersion and minimal values during daytime emersion. Comparison of the heart rates measured in the field with data previously measured in the laboratory indicates that laboratory results seriously underestimate heart rate activity, by as much as 75%, especially during immersion. Unexpectedly, field estimates of body temperatures indicated an ability to tolerate temperatures considered lethal on the basis of laboratory measurements. This suggests that the interaction of abiotic conditions in the field does not necessarily raise vulnerability to high temperatures. PMID:26840775
Nagel, C; Erber, R; Bergmaier, C; Wulf, M; Aurich, J; Möstl, E; Aurich, C
2012-09-01
The mechanisms leading to parturition in the horse in many aspects differ from those in other species. Pregnancy is maintained not by progesterone but by 5α-pregnanes and the progestin precursor pregnenolone originates from the fetus. As parturition approaches, the fetal adrenal switches from pregnenolone to cortisol synthesis but it is not known whether cortisol crosses the placenta. We hypothesized that in parallel to fetal cortisol release, cortisol in the maternal circulation increases before foaling and this increase can be determined in both saliva and plasma. In addition, maternal, fetal and neonatal heart rate and heart rate variability were measured. In 25 pregnant mares, saliva for cortisol analysis was collected 4 times daily from 15 days before to 5 days after foaling. In 13 mares, in addition, fetomaternal electrocardiogram (ECG) recordings were made and blood samples for progestin and cortisol analysis were collected once daily. Heart rate (HR) was recorded until 5 days after foaling. The heart rate variability (HRV) variables standard deviation of the beat-to-beat (RR) interval (SDRR) and root mean square of successive RR differences (RMSSD) were calculated. From Days 15 to 4 before parturition, progestin concentration increased (peak 267 ± 42 ng/mL) and decreased thereafter (P < 0.05, day of foaling 113 ± 18 ng/mL). A prepartum increase in maternal cortisol concentrations was evident in blood (P < 0.05) and saliva (P < 0.05) and paralleled the decrease in progestin concentrations. In mares, HR remained constant during the last days of pregnancy but decreased within one day after parturition (P < 0.05) while maternal HRV did not change. In the fetus and neonate, HR increased from before to after birth (P < 0.05) indicating increasing demands on the cardiovascular system with adaptation to extrauterine life. Copyright © 2012 Elsevier Inc. All rights reserved.
Diego, Rodrigo; Douet, Cécile; Reigner, Fabrice; Blard, Thierry; Cognié, Juliette; Deleuze, Stefan; Goudet, Ghylène
2016-10-15
Transvaginal ultrasound-guided follicular punctures are widely used in the mare for diagnosis, research, and commercial applications. The objective of our study was to determine their influence on pain, stress, and well-being in the mare, by evaluating heart rate, breath rate, facial expression changes, and salivary cortisol before, during, and after puncture. For this experiment, 21 pony mares were used. Transvaginal ultrasound-guided aspirations were performed on 11 mares. After injections for sedation, analgesia, and antispasmodia, the follicles from both ovaries were aspirated with a needle introduced through the vagina wall into the ovary. In the control group, 10 mares underwent similar treatments and injections, but no follicular aspiration. Along the session, heart rate and breath rate were evaluated by a trained veterinarian, ears position, eyelid closure, and contraction of facial muscles were evaluated, and salivary samples were taken for evaluation of cortisol concentration. A significant relaxation was observed after sedative injection in the punctured and control mares, according to ear position, eyelid closure, and contraction of facial muscles, but no difference between punctured and control animals was recorded. No significant modification of salivary cortisol concentration during puncture and no difference between punctured and control mares at any time were observed. No significant modification of the breath rate was observed along the procedure for the punctured and the control mares. Heart rate increased significantly but transiently when the needle was introduced in the ovary and was significantly higher at that time for the punctured mares than that for control mares. None of the other investigated parameters were affected at that time, suggesting discomfort is minimal and transient. Improving analgesia, e.g., through a multimodal approach, during that possibly more sensitive step could be recommended. The evaluation of facial expression changes and heart rate is easy-to-use and accurate tools to evaluate pain and well-being of the mare. Copyright © 2016 Elsevier Inc. All rights reserved.
Adaptive motion artifact reducing algorithm for wrist photoplethysmography application
NASA Astrophysics Data System (ADS)
Zhao, Jingwei; Wang, Guijin; Shi, Chenbo
2016-04-01
Photoplethysmography (PPG) technology is widely used in wearable heart pulse rate monitoring. It might reveal the potential risks of heart condition and cardiopulmonary function by detecting the cardiac rhythms in physical exercise. However the quality of wrist photoelectric signal is very sensitive to motion artifact since the thicker tissues and the fewer amount of capillaries. Therefore, motion artifact is the major factor that impede the heart rate measurement in the high intensity exercising. One accelerometer and three channels of light with different wavelengths are used in this research to analyze the coupled form of motion artifact. A novel approach is proposed to separate the pulse signal from motion artifact by exploiting their mixing ratio in different optical paths. There are four major steps of our method: preprocessing, motion artifact estimation, adaptive filtering and heart rate calculation. Five healthy young men are participated in the experiment. The speeder in the treadmill is configured as 12km/h, and all subjects would run for 3-10 minutes by swinging the arms naturally. The final result is compared with chest strap. The average of mean square error (MSE) is less than 3 beats per minute (BPM/min). Proposed method performed well in intense physical exercise and shows the great robustness to individuals with different running style and posture.
All human Na(+)-K(+)-ATPase alpha-subunit isoforms have a similar affinity for cardiac glycosides.
Wang, J; Velotta, J B; McDonough, A A; Farley, R A
2001-10-01
Three alpha-subunit isoforms of the sodium pump, which is the receptor for cardiac glycosides, are expressed in human heart. The aim of this study was to determine whether these isoforms have distinct affinities for the cardiac glycoside ouabain. Equilibrium ouabain binding to membranes from a panel of different human tissues and cell lines derived from human tissues was compared by an F statistic to determine whether a single population of binding sites or two populations of sites with different affinities would better fit the data. For all tissues, the single-site model fit the data as well as the two-site model. The mean equilibrium dissociation constant (K(d)) for all samples calculated using the single-site model was 18 +/- 6 nM (mean +/- SD). No difference in K(d) was found between nonfailing and failing human heart samples, although the maximum number of binding sites in failing heart was only approximately 50% of the number of sites in nonfailing heart. Measurement of association rate constants and dissociation rate constants confirmed that the binding affinities of the different human alpha-isoforms are similar to each other, although calculated K(d) values were lower than those determined by equilibrium binding. These results indicate both that the affinity of all human alpha-subunit isoforms for ouabain is similar and that the increased sensitivity of failing human heart to cardiac glycosides is probably due to a reduction in the number of pumps in the heart rather than to a selective inhibition of a subset of pumps with different affinities for the drugs.
Heart Rate Variability and Wavelet-based Studies on ECG Signals from Smokers and Non-smokers
NASA Astrophysics Data System (ADS)
Pal, K.; Goel, R.; Champaty, B.; Samantray, S.; Tibarewala, D. N.
2013-12-01
The current study deals with the heart rate variability (HRV) and wavelet-based ECG signal analysis of smokers and non-smokers. The results of HRV indicated dominance towards the sympathetic nervous system activity in smokers. The heart rate was found to be higher in case of smokers as compared to non-smokers ( p < 0.05). The frequency domain analysis showed an increase in the LF and LF/HF components with a subsequent decrease in the HF component. The HRV features were analyzed for classification of the smokers from the non-smokers. The results indicated that when RMSSD, SD1 and RR-mean features were used concurrently a classification efficiency of > 90 % was achieved. The wavelet decomposition of the ECG signal was done using the Daubechies (db 6) wavelet family. No difference was observed between the smokers and non-smokers which apparently suggested that smoking does not affect the conduction pathway of heart.
Menown, Ian BA; Davies, Simon; Gupta, Sandeep; Kalra, Paul R; Lang, Chim C; Morley, Chris; Padmanabhan, Sandosh
2013-01-01
Background Data from large epidemiological studies suggest that elevated heart rate is independently associated with cardiovascular and all-cause mortality in patients with hypertension and in those with established cardiovascular disease. Clinical trial findings also suggest that the favorable effects of beta-blockers and other heart rate–lowering agents in patients with acute myocardial infarction and congestive heart failure may be, at least in part, due to their heart rate–lowering effects. Contemporary clinical outcome prediction models such as the Global Registry of Acute Coronary Events (GRACE) score include admission heart rate as an independent risk factor. Aims This article critically reviews the key epidemiology concerning heart rate and cardiovascular risk, potential mechanisms through which an elevated resting heart rate may be disadvantageous and evaluates clinical trial outcomes associated with pharmacological reduction in resting heart rate. Conclusions Prospective randomised data from patients with significant coronary heart disease or heart failure suggest that intervention to reduce heart rate in those with a resting heart rate >70 bpm may reduce cardiovascular risk. Given the established observational data and randomised trial evidence, it now appears appropriate to include reduction of elevated resting heart rate by lifestyle +/− pharmacological therapy as part of a secondary prevention strategy in patients with cardiovascular disease. PMID:22954325
Comparison of heart rate variability and pulse rate variability detected with photoplethysmography
NASA Astrophysics Data System (ADS)
Rauh, Robert; Limley, Robert; Bauer, Rainer-Dieter; Radespiel-Troger, Martin; Mueck-Weymann, Michael
2004-08-01
This study compares ear photoplethysmography (PPG) and electrocardiogram (ECG) in providing accurate heart beat intervals for use in calculations of heart rate variability (HRV, from ECG) or of pulse rate variability (PRV, from PPG) respectively. Simultaneous measurements were taken from 44 healthy subjects at rest during spontaneous breathing and during forced metronomic breathing (6/min). Under both conditions, highly significant (p > 0.001) correlations (1.0 > r > 0.97) were found between all evaluated common HRV and PRV parameters. However, under both conditions the PRV parameters were higher than HRV. In addition, we calculated the limits of agreement according to Bland and Altman between both techniques and found good agreement (< 10% difference) for heart rate and standard deviation of normal-to-normal intervals (SDNN), but only moderate (10-20%) or even insufficient (> 20%) agreement for other standard HRV and PRV parameters. Thus, PRV data seem to be acceptable for screening purposes but, at least at this state of knowledge, not for medical decision making. However, further studies are needed before more certain determination can be made.
Effects of different training amplitudes on heart rate and heart rate variability in young rowers.
Vaz, Marcelo S; Picanço, Luan M; Del Vecchio, Fabrício B
2014-10-01
The aim of this study was to investigate the autonomic nervous system recovery and the psychological response as a result of 3 training amplitudes on heart rate (HR), heart rate variability (HRV), and rate of perceived exertion (RPE) in rowing. Eight young rowers (16.8 ± 1.4 years) performed, in a randomized fashion, 2 sessions of high-intensity interval training, with high and low amplitude and a continuous training (CT) session, with the same exercise duration (10 minutes) and mean intensity (60% of maximal stroke test). The data of HR, HRV, and RPE were collected 5 minutes before, immediately after each session, and 24 hours later. High amplitude promoted higher impact in maximum HR (p ≤ 0.05) and RPE (p < 0.001) when compared with CT. For the time domain HRV variable, there was a statistically significant difference between moments of rest (pretraining or post 24 hours) and posttraining in all training sessions. Originally, we conclude that training with higher load variation between effort and recovery impacts HRV, HR, and RPE with greater intensity, but the younger rowers were ready for new training sessions 24 hours after either training method. Coaches can use the polarized training method, observing the stimulus nature and time required for recovery, because it may be an adequate strategy for the development of rower's conditioning.
The mitochondrial uniporter controls fight or flight heart rate increases.
Wu, Yuejin; Rasmussen, Tyler P; Koval, Olha M; Joiner, Mei-Ling A; Hall, Duane D; Chen, Biyi; Luczak, Elizabeth D; Wang, Qiongling; Rokita, Adam G; Wehrens, Xander H T; Song, Long-Sheng; Anderson, Mark E
2015-01-20
Heart rate increases are a fundamental adaptation to physiological stress, while inappropriate heart rate increases are resistant to current therapies. However, the metabolic mechanisms driving heart rate acceleration in cardiac pacemaker cells remain incompletely understood. The mitochondrial calcium uniporter (MCU) facilitates calcium entry into the mitochondrial matrix to stimulate metabolism. We developed mice with myocardial MCU inhibition by transgenic expression of a dominant-negative (DN) MCU. Here, we show that DN-MCU mice had normal resting heart rates but were incapable of physiological fight or flight heart rate acceleration. We found that MCU function was essential for rapidly increasing mitochondrial calcium in pacemaker cells and that MCU-enhanced oxidative phoshorylation was required to accelerate reloading of an intracellular calcium compartment before each heartbeat. Our findings show that MCU is necessary for complete physiological heart rate acceleration and suggest that MCU inhibition could reduce inappropriate heart rate increases without affecting resting heart rate.
Web-based comparison of historical vs contemporary methods of fetal heart rate interpretation.
Epstein, Aaron J; Iriye, Brian K; Hancock, Lyle; Quilligan, Edward J; Rumney, Pamela J; Hancock, Judy; Ghamsary, Mark; Eakin, Cortney M; Smith, Cheryl; Wing, Deborah A
2016-10-01
Contemporary interpretation of fetal heart rate patterns is based largely on the tenets of Drs Quilligan and Hon. This method differs from an older method that was championed by Dr Caldeyro-Barcia in recording speed and classification of decelerations. The latter uses a paper speed of 1 cm/min and classifies decelerations referent to uterine contractions as type I or II dips, compared with conventional classification as early, late, or variable with paper speed of 3 cm/min. We hypothesized that 3 cm/min speed may lead to over-analysis of fetal heart rate and that 1 cm/min may provide adequate information without compromising accuracy or efficiency. The purpose of this study was to compare the Hon-Quilligan method of fetal heart rate interpretation with the Caldeyro-Barcia method among groups of obstetrics care providers with the use of an online interactive testing tool. We deidentified 40 fetal heart rate tracings from the terminal 30 minutes before delivery. A website was created to view these tracings with the use of the standard Hon-Quilligan method and adjusted the same tracings to the 1 cm/min monitoring speed for the Caldeyro-Barcia method. We invited 2-4 caregivers to participate: maternal-fetal medicine experts, practicing maternal-fetal medicine specialists, maternal-fetal medicine fellows, obstetrics nurses, and certified nurse midwives. After completing an introductory tutorial and quiz, they were asked to interpret the fetal heart rate tracings (the order was scrambled) to manage and predict maternal and neonatal outcomes using both methods. Their results were compared with those of our expert, Edward Quilligan, and were compared among groups. Analysis was performed with the use of 3 measures: percent classification, Kappa, and adjusted Gwet-Kappa (P < .05 was considered significant). Overall, our results show from moderate to almost perfect agreement with the expert and both between and within examiners (Gwet-Kappa 0.4-0.8). The agreement at each stratum of practitioner was generally highest for ascertainment of baseline and for management; the least agreement was for assessment of variability. We examined the agreement of fetal heart rate interpretation with a defined set of rules among a number of different obstetrics practitioners using 3 different statistical methods and found moderate-to-substantial agreement among the clinicians for matching the interpretation of the expert. This implies that the simpler Caldeyro-Barcia method may perform as well as the newer classification system. Copyright © 2016 Elsevier Inc. All rights reserved.
Chen, Chien-Liang; Tang, Jing-Shia; Li, Ping-Chia; Chou, Pi-Ling
2015-01-01
This study compared the immediate effects of smoking on cardiorespiratory responses to dynamic arm and leg exercises. This randomized crossover study recruited 14 college students. Each participant underwent two sets of arm-cranking (AC) and leg-cycling (LC) exercise tests. The testing sequences of the control trial (participants refrained from smoking for 8 h before testing) and the experimental trial (participants smoked two cigarettes immediately before testing) were randomly chosen. We observed immediate changes in pulmonary function and heart rate variability after smoking and before the exercise test. The participants then underwent graded exercise tests of their arms and legs until reaching exhaustion. We compared the peak work achieved and time to exhaustion during the exercise tests with various cardiorespiratory indices [i.e., heart rate, oxygen consumption (VO2), minute ventilation (VE)]. The differences between the smoking and control trials were calculated using paired t-tests. For the exercise test periods, VO2, heart rate, and VE values were calculated at every 10% increment of the maximal effort time. The main effects of the time and trial, as well as their trial-by-time (4 × 10) interaction effects on the outcome measures, were investigated using repeated measure ANOVA with trend analysis. 5 min after smoking, the participants exhibited reduced forced vital capacities and forced expiratory volumes in the first second (P < 0.05), in addition to elevated resting heart rates (P < 0.001). The high-frequency, low-frequency, and the total power of the heart rate variability were also reduced (P < 0.05) at rest. For the exercise test periods, smoking reduced the time to exhaustion (P = 0.005) and the ventilatory threshold (P < 0.05) in the LC tests, whereas no significant effects were observed in the AC tests. A trend analysis revealed a significant trial-by-time interaction effect for heart rate, VO2, and VE during the graded exercise test (all P < 0.001). Lower VO2 and VE levels were exhibited in the exercise response of the smoking trial than in those of the control LC trials, whereas no discernable inter-trial difference was observed in the AC trials. Moreover, the differences in heart rate and VE response between the LC and AC exercises were significantly smaller after the participants smoked. This study verified that smoking significantly decreased performance and cardiorespiratory responses to leg exercises. However, the negative effects of smoking on arm exercise performance were not as pronounced.
Cobretti, Michael R; Bowman, Benjamin; Grabarczyk, Ted; Potter, Emily
2018-03-01
The dipeptidyl peptidase-4 inhibitors (DPP-4 inhibitors) are effective modulators of fasting and postprandial hyperglycemia in patients with type 2 diabetes mellitus (T2DM). In 2013 the Saxagliptin Assessment of Vascular Outcomes Recorded in Patients with Diabetes Mellitus-Thrombolysis in Myocardial Infarction 53 (SAVOR-TIMI 53) clinical trial found an increased risk of heart failure exacerbation, as a secondary outcome, among patients treated with saxagliptin. This study examines the safety of DPP-4 inhibitors as a class in T2DM in relation to risk of heart failure exacerbations. Retrospective cohort study of two groups of patients using data from the national Department of Veteran's Affairs (VA) Health Care System: patients initially prescribed DPP-4 inhibitors with or without second-generation sulfonylureas and/or metformin (exposed group) compared with patients initially prescribed only second-generation sulfonylureas and/or metformin (unexposed group) between August 1, 2013, and August 30, 2016. The primary aim of this study was to determine the difference in 1-year heart failure exacerbation rate in patients with T2DM between the exposed and unexposed groups. Data were analyzed using the χ 2 Student t test and Kaplan-Meier analysis. Significance was set at p<0.05. The study evaluated 672,265 patients: 33,614 patients in the exposed group and 638,651 patients in the unexposed group. Overall, 130 (0.38%) heart failure exacerbations were documented in the exposed group, and 2222 (0.34%) heart failure exacerbations were documented in the unexposed group; the difference in exacerbation rate was nonsignificant between groups (p=0.24). In a subgroup analysis of patients with a baseline diagnosis of heart failure, the difference in rate of heart failure exacerbations remained nonsignificant (p=0.334). Patients in the veteran population with T2DM treated with DPP-4 inhibitors did not demonstrate a significant increase in risk for heart failure exacerbation, regardless of whether a patient had been previously diagnosed with heart failure. This finding potentially supports safe usage of DPP-4 inhibitors in this patient population regardless of heart failure diagnosis. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Austin, Peter C; Goldwasser, Meredith A
2008-03-01
We examined the impact on statistical inference when a chi(2) test is used to compare the proportion of successes in the level of a categorical variable that has the highest observed proportion of successes with the proportion of successes in all other levels of the categorical variable combined. Monte Carlo simulations and a case study examining the association between astrological sign and hospitalization for heart failure. A standard chi(2) test results in an inflation of the type I error rate, with the type I error rate increasing as the number of levels of the categorical variable increases. Using a standard chi(2) test, the hospitalization rate for Pisces was statistically significantly different from that of the other 11 astrological signs combined (P=0.026). After accounting for the fact that the selection of Pisces was based on it having the highest observed proportion of heart failure hospitalizations, subjects born under the sign of Pisces no longer had a significantly higher rate of heart failure hospitalization compared to the other residents of Ontario (P=0.152). Post hoc comparisons of the proportions of successes across different levels of a categorical variable can result in incorrect inferences.
Gröpel, Peter; Urner, Maren; Pruessner, Jens C; Quirin, Markus
2018-01-01
Evidence shows that regular physical exercise reduces physiological reactivity to psychosocial stress. However, previous research mainly focused on the effect of endurance exercise, with only a few studies looking at the effect of resistance exercise. The current study tested whether individuals who regularly participate in either endurance or resistance training differ from untrained individuals in adrenal and cardiovascular reactivity to psychosocial stress. Twelve endurance-trained men, 10 resistance-trained men, and 12 healthy but untrained men were exposed to a standardized psychosocial stressor, the Trier Social Stress Test. Measurements of heart rate, free salivary cortisol levels, and mood were obtained throughout the test and compared among the three groups. Overall, both endurance- and resistance-trained men had lower heart rate levels than untrained men, indicating higher cardiac performance of the trained groups. Trained men also exhibited lower heart rate responses to psychosocial stress compared with untrained men. There were no significant group differences in either cortisol responses or mood responses to the stressor. The heart rate results are consistent with previous studies indicating reduced cardiovascular reactivity to psychosocial stress in trained individuals. These findings suggest that long-term endurance and resistance trainings may be related to the same cardiovascular benefits, without exhibiting strong effects on the cortisol reactivity to stress.
When an Increase in Central Systolic Pressure Overrides the Benefits of Heart Rate Lowering.
Messerli, Franz H; Rimoldi, Stefano F; Bangalore, Sripal; Bavishi, Chirag; Laurent, Stephane
2016-08-16
An elevated resting heart rate has been unequivocally linked to adverse cardiovascular events. Conversely, a physiologically low heart rate may confer longevity benefits. Moreover, pharmacological heart rate lowering reduces cardiovascular outcomes in patients with heart failure, with the magnitude of the reduction associated with survival benefit. In contrast, pharmacological heart rate lowering paradoxically increases cardiovascular events in hypertension, possibly because it elicits a ventricular-vascular mismatch, leading to increased central systolic blood pressure (BP). By the same hemodynamic mechanism, pharmacological heart rate lowering also engenders an increase in central (aortic) BP in coronary heart disease and, as a consequence, fails to decrease myocardial oxygen consumption. Whether in heart failure, hypertension, or coronary heart disease, or even athletes, heart rate lowering consistently increases central systolic pressure. The increase in central systolic BP is prone to abolish the potential benefits of heart rate lowering interventions, possibly accounting for failure to reduce outcomes in patients with hypertension and coronary artery disease. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Heart rate monitoring mobile applications
2016-01-01
Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone’s camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, ‘Unique Heart Rate Monitor’, you can also maintain your heart rate history for personal reflection and sharing with a provider. PMID:28293594
Heart rate variability of human in hypoxic oxygen-argon environment
NASA Astrophysics Data System (ADS)
Khayrullina, Rezeda; Smoleevskiy, Alexandr; Bubeev, Yuri
Human adaptive capacity, reliability and stability in extreme environments depend primarily on the individual resistance to stresses, includes both innate and acquired components. We have conducted studies in six healthy subjects - men aged between 24 to 42 years who psychophysiological indicators acterizing the severity of stress reactions studied directly during an emergency situation, before and after it. The subjects were in a hypoxic oxygen-argon atmosphere 10 days. Cardiovascular system is one of the first to respond to stressful reaction. The method of heart rate variability (HRV) allows us to estimate balance of sympathetic and parasympathetic parts of vegetative nervous system. In the course of the baseline study it was found that resting heart rate (HR) in the examined individuals is within normal limits. During the experiment in all subjects there was a trend towards more frequent heartbeat. Each subject at one stage or another stay in a hypoxic oxygen-argon environment heart rate go beyond the group norm, but the extent and duration of these abnormalities were significantly different. Marked increase in middle heart rate during of subjects experiment, fluctuating within a wide range (from 2.3% to 29.1%). Marked increase in middle heart rate during of subjects experiment, fluctuating within a wide range (from 2.3% to 29.1%). This suggests that the ability to adapt to living in the investigated gas environment have marked individual differences. SDNN (mean square deviation of all R-R intervals) is the integral indicator of the total effect of the sinus node to the sympathetic and parasympathetic parts of vegetative nervous system, as well as indicating the higher functional reserves of the cardiovascular systems. Increase in heart rate in the majority of subject was accompanied by an increase in individual SDNN. This suggests that the parasympathetic system is able to balance the increase in activity of the sympathetic system, and functional reserves are sufficient. However, the opposite dynamic test 02 - accompanied by a decrease heart rate increase SDNN. The survey detected that all subjects marked signs of increased activity of the sympathetic nervous system. Besides when short-term exposure (up to 10 days) in most researched factor in the majority of patients was enough functional reserves to adapt to the conditions of a changed atmosphere. However, the adaptation process was accompanied by severe stress and compensatory mechanisms for longer stay in hypoxic conditions, oxygen-argon environment may develop adverse effects associated with sympathicotony.
Tu, Jack V.; Nardi, Lorelei; Fang, Jiming; Liu, Juan; Khalid, Laila; Johansen, Helen
2009-01-01
Background Rates of death from cardiovascular and cerebrovascular diseases have been steadily declining over the past few decades. Whether such declines are occurring to a similar degree for common disorders such as acute myocardial infarction, heart failure and stroke is uncertain. We examined recent national trends in mortality and rates of hospital admission for these 3 conditions. Methods We analyzed mortality data from Statistic Canada’s Canadian Mortality Database and data on hospital admissions from the Canadian Institute for Health Information’s Hospital Morbidity Database for the period 1994–2004. We determined age- and sex-standardized rates of death and hospital admissions per 100 000 population aged 20 years and over as well as in-hospital case-fatality rates. Results The overall age- and sex-standardized rate of death from cardiovascular disease in Canada declined 30.0%, from 360.6 per 100 000 in 1994 to 252.5 per 100 000 in 2004. During the same period, the rate fell 38.1% for acute myocardial infarction, 23.5% for heart failure and 28.2% for stroke, with improvements observed across most age and sex groups. The age- and sex-standardized rate of hospital admissions decreased 27.6% for stroke and 27.2% for heart failure. The rate for acute myocardial infarction fell only 9.2%. In contrast, the relative decline in the inhospital case-fatality rate was greatest for acute myocardial infarction (33.1%; p < 0.001). Much smaller relative improvements in case-fatality rates were noted for heart failure (8.1%) and stroke (8.9%). Interpretation The rates of death and hospital admissions for acute myocardial infarction, heart failure and stroke in Canada changed at different rates over the 10-year study period. Awareness of these trends may guide future efforts for health promotion and health care planning and help to determine priorities for research and treatment. PMID:19546444
Meyer, Markus; Rambod, Mehdi; LeWinter, Martin
2018-07-01
Epidemiological studies have demonstrated that high resting heart rates are associated with increased mortality. Clinical studies in patients with heart failure and reduced ejection fraction have shown that heart rate lowering with beta-blockers and ivabradine improves survival. It is therefore often assumed that heart rate lowering is beneficial in other patients as well. Here, we critically appraise the effects of pharmacological heart rate lowering in patients with both normal and reduced ejection fraction with an emphasis on the effects of pharmacological heart rate lowering in hypertension and heart failure. Emerging evidence from recent clinical trials and meta-analyses suggest that pharmacological heart rate lowering is not beneficial in patients with a normal or preserved ejection fraction. This has just begun to be reflected in some but not all guideline recommendations. The detrimental effects of pharmacological heart rate lowering are due to an increase in central blood pressures, higher left ventricular systolic and diastolic pressures, and increased ventricular wall stress. Therefore, we propose that heart rate lowering per se reproduces the hemodynamic effects of diastolic dysfunction and imposes an increased arterial load on the left ventricle, which combine to increase the risk of heart failure and atrial fibrillation. Pharmacologic heart rate lowering is clearly beneficial in patients with a dilated cardiomyopathy but not in patients with normal chamber dimensions and normal systolic function. These conflicting effects can be explained based on a model that considers the hemodynamic and ventricular structural effects of heart rate changes.
Marso, Steven P; Hardy, Elise; Han, Jenny; Wang, Hui; Chilton, Robert J
2018-04-01
Glucagon-like peptide-1 receptor agonists (GLP-1RAs) improve glycemia in patients with type 2 diabetes, but heart rate increases have been observed. A pooled post hoc analysis of 11 randomized clinical trials (N = 4595) of 10-30 weeks' duration from the exenatide once-weekly (QW) development program evaluated heart rate with exenatide QW (intervention group) and exenatide twice daily (BID), liraglutide, and non-GLP-1RAs (insulin, metformin, pioglitazone, and sitagliptin) (comparison groups). The time course and size of heart rate changes from baseline and the relationship of heart rate change with baseline heart rate were studied. A multivariate analysis (9 studies; N = 3903) examined associations between patient characteristics or treatments and heart rate increases. Mean baseline heart rate ± standard deviation was 75.0 ± 8.5 beats per minute (bpm) with exenatide QW (n = 2096), 75.8 ± 8.7 bpm with exenatide BID (n = 606), 75.2 ± 8.9 bpm with liraglutide (n = 450), and 74.5 ± 8.6 bpm with non-GLP-1RAs (n = 1443). Least-squares mean ± standard error changes from baseline to final heart rate were + 2.7 ± 0.2, + 1.0 ± 0.3, and + 3.0 ± 0.4 bpm with exenatide QW, exenatide BID, and liraglutide, respectively, and - 0.8 ± 0.2 bpm with non-GLP-1RAs. The size and direction of heart rate changes in individual patients varied within each treatment group at all time points. At posttreatment follow-up, heart rate reverted to the baseline level after GLP-1RA discontinuation. Heart rate changes correlated negatively with baseline heart rate for all therapies (r = - 0.3 to - 0.4). Baseline heart rate was the strongest predictor of increased heart rate. Small increases in heart rate were associated with exenatide QW, exenatide BID, and liraglutide treatments but reverted to baseline after discontinuation. Increases were more likely in patients with a low baseline heart rate. The clinical relevance of these heart rate increases is unknown but will be clarified by several ongoing and recently completed cardiovascular outcome studies.
Effects of changes in vertical occlusal dimension on heart rate fluctuations in guinea pigs.
Taga, Hitoshi; Azuma, Yukio; Maehara, Kiyoshi; Nomura, Shuichi
2012-01-01
We have previously reported that the decrease of the vertical occlusal dimension (VOD) led to heart failure and abnormalities in creatine phosphokinase (CPK) in guinea pigs. In the present study, we investigated the autonomic activity and the origin of the abnormality in CPK under different occlusal conditions. Guinea pigs were separated into the following five groups: untreated control, reduced VOD, slit, restored VOD and increased VOD groups and compared for their electrocardiogram and heart rate fluctuations for two weeks using Fluclet, computer software. The control group revealed no changes in heart rate fluctuations or posture. The reduced VOD group exhibited a two-phase wave of heart rate fluctuations, with the first peak 0-2 days after teeth grinding, and the second peak starting from 4 days after teeth grinding until sudden death (usually 12th day), accompanied by head drop. The slit and the restored VOD groups exhibited only the first peak. The increased VOD group, with approximately 3 mm-thick acrylic pellets bonded to the posterior teeth, showed no heart rate fluctuations. Body weight loss was most prominent in the reduced VOD group, and became much milder in the order of increased VOD, restored and slit groups. The reduced VOD group exhibited transient elevation of skeletal muscle type of CPK isozyme activity within two days after treatment. The present study suggests that the first peak of heart rate fluctuations is caused by pulpal stimulation, and the second peak by excessive contraction (excessive excitation of the motor output system and the autonomic nervous system) of the masticatory muscles. On the other hand, increased VOD did not influence either the motor or the autonomic nervous system.
Kizilay, Deniz; Dal, Didem; Saracoglu, Kemal T; Eti, Zeynep; Gogus, Fevzi Y
2016-02-01
The aim of this study is to compare the hemodynamic effects of neostigmine-atropine combination and sugammadex in patients with cardiac problems undergoing noncardiac surgery. Prospective randomized study. In the operating room. Ninety patients with a class 2 or 3 cardiovascular disease according to the New York Heart Association classification and aged between 18 and 75 years undergoing noncardiac surgery were randomized. Group N (n = 45) received 0.03 mg/kg IV neostigmine when T2 appeared as measured with a nerve muscle stimulator. When heart rate was 5 beats/min (±10 beats/min) lower than the heart rate before administration of the medication, 0.5 mg IV atropine sulfate was given. Group S (n = 45) received 3 mg/kg IV sugammadex when T2 appeared as measured with a nerve muscle stimulator. Heart rate, mean systolic and diastolic blood pressures, and electrocardiographic alterations including the QTc (QT Fredericia and QT Bazett) were recorded. There were no significant differences between and within the groups in terms of QTc values. Sugammadex group had a significant decrease on heart rate 1 minute after the medication when compared to the measurement before the medication (P < .05). Heart rate and systolic blood pressure increased in neostigmine group 3 minutes after the medication and during postoperative measurements (P < .05). Sugammadex group had lower systolic, diastolic, and mean blood pressures and heart rate when compared to neostigmine group (P < .05). We suggest that sugammadex might be preferred as it provides more hemodynamic stability compared to neostigmine-atropine combination to reverse rocuronium-induced neuromuscular blockage in cardiac patients undergoing noncardiac surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Framing the ultimatum game: gender differences and autonomic responses.
Sarlo, Michela; Lotto, Lorella; Palomba, Daniela; Scozzari, Simona; Rumiati, Rino
2013-01-01
The present study aimed at investigating whether the way offers are framed in the Ultimatum Game (UG) affects behavioral and autonomic responses in men and women. The "I give you" and "I take" expressions were used as gain and loss frames, respectively. Skin conductance and heart rate were recorded as indices of autonomic activation in response to unfair, mid-value, and fair offers. Acceptance rates were higher in men than in women under the gain frame. Moreover, men showed higher acceptance rates under the gain than under the loss frame with mid-value offers, whereas women's choices were not affected by frame. On the physiological level, men produced differential autonomic response patterns during decision-making when offers were presented under gain and loss framing. The "I take" frame, by acting as a loss frame, elicited in men the characteristic defensive response pattern that is evoked by aversive stimulation, in which increases in skin conductance are coupled with increases in heart rate. On the other hand, the "I give you" frame, by acting as a gain frame, elicited in men increases in skin conductance associated with prevailing heart rate deceleratory responses, reflecting a state of enhanced attention and orienting. In contrast, women's autonomic reactivity was not affected by frame, consistent with behavioral results. Phasic changes in heart rate were crucial in revealing differential functional significance of skin conductance responses under different frames in men, thus questioning the assumption that this autonomic measure can be used as an index of negative emotional arousal in the UG.
Losa-Iglesias, Marta Elena; Becerro-de-Bengoa-Vallejo, Ricardo; Becerro-de-Bengoa-Losa, Klark Ricardo
2016-06-01
There are downloadable applications (Apps) for cell phones that can measure heart rate in a simple and painless manner. The aim of this study was to assess the reliability of this type of App for a Smartphone using an Android system, compared to the radial pulse and a portable pulse oximeter. We performed a pilot observational study of diagnostic accuracy, randomized in 46 healthy volunteers. The patients' demographic data and cardiac pulse were collected. Radial pulse was measured by palpation of the radial artery with three fingers at the wrist over the radius; a low-cost portable, liquid crystal display finger pulse oximeter; and a Heart Rate Plus for Samsung Galaxy Note®. This study demonstrated high reliability and consistency between systems with respect to the heart rate parameter of healthy adults using three systems. For all parameters, ICC was > 0.93, indicating excellent reliability. Moreover, CVME values for all parameters were between 1.66-4.06 %. We found significant correlation coefficients and no systematic differences between radial pulse palpation and pulse oximeter and a high precision. Low-cost pulse oximeter and App systems can serve as valid instruments for the assessment of heart rate in healthy adults. © The Author(s) 2014.
Noncontact measurement of emotional and physiological changes in heart rate from a webcam.
Madan, Christopher R; Harrison, Tyler; Mathewson, Kyle E
2018-04-01
Heart rate, measured in beats per minute, can be used as an index of an individual's physiological state. Each time the heart beats, blood is expelled and travels through the body. This blood flow can be detected in the face using a standard webcam that is able to pick up subtle changes in color that cannot be seen by the naked eye. Due to the light absorption spectrum of blood, we are able to detect differences in the amount of light absorbed by the blood traveling just below the skin (i.e., photoplethysmography). By modulating emotional and physiological stress-that is, viewing arousing images and sitting versus standing, respectively-to elicit changes in heart rate, we explored the feasibility of using a webcam as a psychophysiological measurement of autonomic activity. We found a high level of agreement between established physiological measures, electrocardiogram, and blood pulse oximetry, and heart rate estimates obtained from the webcam. We thus suggest webcams can be used as a noninvasive and readily available method for measuring psychophysiological changes, easily integrated into existing stimulus presentation software and hardware setups. © 2017 Society for Psychophysiological Research.
Kur'yanova, E V; Teplyi, D L; Zhukova, Yu D; Zhukovina, N V
2015-12-01
The basic behavioral activity of nonlinear rats was evaluated from the sum of crossed peripheral and central squares and peripheral and central rearing postures in the open fi eld test. This index was low (<20 episodes), intermediate (20-29 episodes), or high (>30 episodes). Male rats with high score of orientation and exploratory activity were characterized by higher indexes of total heart rate variability than rats with low or intermediate activity. Specimens with a greater contribution of VLF waves into the total power spectrum of heart rate variability were shown to dominate among the rats with high behavioral activity. Our results are consistent with the notions of a suprasegmental nature of VLF waves.
Ozcelik, O; Kelestimur, H
2004-01-01
Anaerobic threshold which describes the onset of systematic increase in blood lactate concentration is a widely used concept in clinical and sports medicine. A deflection point between heart rate-work rate has been introduced to determine the anaerobic threshold non-invasively. However, some researchers have consistently reported a heart rate deflection at higher work rates, while others have not. The present study was designed to investigate whether the heart rate deflection point accurately predicts the anaerobic threshold under the condition of acute hypoxia. Eight untrained males performed two incremental exercise tests using an electromagnetically braked cycle ergometer: one breathing room air and one breathing 12 % O2. The anaerobic threshold was estimated using the V-slope method and determined from the increase in blood lactate and the decrease in standard bicarbonate concentration. This threshold was also estimated by in the heart rate-work rate relationship. Not all subjects exhibited a heart rate deflection. Only two subjects in the control and four subjects in the hypoxia groups showed a heart rate deflection. Additionally, the heart rate deflection point overestimated the anaerobic threshold. In conclusion, the heart rate deflection point was not an accurate predictor of anaerobic threshold and acute hypoxia did not systematically affect the heart rate-work rate relationships.
2011-01-01
Background Carvedilol has been shown to be superior to metoprolol tartrate to improve clinical outcomes in patients with heart failure (HF), yet the mechanisms responsible for these differences remain unclear. We examined if there were differences in endothelial function, insulin stimulated endothelial function, 24 hour ambulatory blood pressure and heart rate during treatment with carvedilol, metoprolol tartrate and metoprolol succinate in patients with HF. Methods Twenty-seven patients with mild HF, all initially treated with carvedilol, were randomized to a two-month treatment with carvedilol, metoprolol tartrate or metoprolol succinate. Venous occlusion plethysmography, 24-hour blood pressure and heart rate measurements were done before and after a two-month treatment period. Results Endothelium-dependent vasodilatation was not affected by changing from carvedilol to either metoprolol tartrate or metoprolol succinate. The relative forearm blood flow at the highest dose of serotonin was 2.42 ± 0.33 in the carvedilol group at baseline and 2.14 ± 0.24 after two months continuation of carvedilol (P = 0.34); 2.57 ± 0.33 before metoprolol tartrate treatment and 2.42 ± 0.55 after treatment (p = 0.74) and in the metoprolol succinate group 1.82 ± 0.29 and 2.10 ± 0.37 before and after treatment, respectively (p = 0.27). Diurnal blood pressures as well as heart rate were also unchanged by changing from carvedilol to metoprolol tartrate or metoprolol succinate. Conclusion Endothelial function remained unchanged when switching the beta blocker treatment from carvedilol to either metoprolol tartrate or metoprolol succinate in this study, where blood pressure and heart rate also remained unchanged in patients with mild HF. Trial registration Current Controlled Trials NCT00497003 PMID:21999413
Lacome, Mathieu; Simpson, Ben M; Cholley, Yannick; Buchheit, Martin
2018-05-01
To (1) compare the locomotor and heart rate responses between floaters and regular players during both small and large small-sided games (SSGs) and (2) examine whether the type of game (ie, game simulation [GS] vs possession game [PO]) affects the magnitude of the difference between floaters and regular players. Data were collected in 41 players belonging to an elite French football team during 3 consecutive seasons (2014-2017). A 5-Hz global positionning system was used to collect all training data, with the Athletic Data Innovation analyzer (v5.4.1.514) used to derive total distance (m), high-speed distance (>14.4 km·h -1 , m), and external mechanical load (MechL, a.u.). All SSGs included exclusively 1 floater and were divided into 2 main categories, according to the participation of goalkeepers (GS) or not (PO) and then further divided into small and large (>100 m 2 per player) SSGs based on the area per player ratio. Locomotor activity and MechL performed were likely-to-most likely lower (moderate to large magnitude) in floaters compared with regular players, whereas differences in heart rate responses were unclear to possibly higher (small) in floaters. The magnitude of the difference in locomotor activity and MechL between floaters and regular players was substantially greater during GS compared with PO. Compared with regular players, floaters present decreased external load (both locomotor and MechL) despite unclear to possibly slightly higher heart rate responses during SSGs. Moreover, the responses of floaters compared with regular players are not consistent across different sizes of SSGs, with greater differences during GS than PO.
Gender- and hydration- associated differences in the physiological response to spinning.
Ramos-Jiménez, Arnulfo; Hernández-Torres, Rosa Patricia; Wall-Medrano, Abraham; Torres-Durán, Patricia Victoria; Juárez-Oropeza, Marco Antonio; Viloria, María; Villalobos-Molina, Rafael
2014-03-01
There is scarce and inconsistent information about gender-related differences in the hydration of sports persons, as well as about the effects of hydration on performance, especially during indoor sports. To determine the physiological differences between genders during in indoor physical exercise, with and without hydration. 21 spinning sportspeople (12 men and 9 women) participated in three controlled, randomly assigned and non-sequential hydration protocols, including no fluid intake and hydration with plain water or a sports drink (volume adjusted to each individual every 15 min), during 90 min of spinning exercise. The response variables included body mass, body temperature, heart rate and blood pressure. During exercise without hydration, men and women lost ~2% of body mass, and showed higher body temperature (~0.2°C), blood pressure (~4 mmHg) and heart rate (~7 beats/min) compared to exercises with hydration. Body temperature and blood pressure were higher for men than for women during exercise without hydration, differences not observed during exercise with hydration. Between 42-99% of variance in body temperature, blood pressure and heart rate could be explained by the physical characteristics of subjects and the work done. During exercise with hydration (either with water or sport drink), the physiological response was similar for both genders. Exercise without hydration produced physical stress, which could be prevented with either of the fluids (plain water was sufficient). Gender differences in the physiological response to spinning (body temperature, mean blood pressure and heart rate) can be explained in part by the distinct physical characteristics of each individual. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Cook, Rosalind F; Bussey, Carol T; Mellor, Kimberley M; Cragg, Patricia A; Lamberts, Regis R
2017-08-01
What is the central question of the study? The sympathetic system regulates heart rate via β-adrenoceptors; this is impaired during diabetes. However, the specific β-adrenoceptor subtype contributions in heart rate regulation in diabetes in vivo are unknown. What is the main finding and its importance? Telemetric recordings in conscious non-diabetic and type 2 diabetic rats demonstrated that the β 1 -adrenoceptor subtype, and not the β 2 -adrenoceptor, regulated the lower resting heart rate and increased β-adrenoceptor responsiveness in diabetes in vivo. This provides new physiological insight into the dysregulation of heart rate in type 2 diabetes, which is important for improving therapeutic strategies targeting the diabetic chronotropic incompetence. β-Adrenoceptor blockers are widely used to reduce heart rate, the strongest predictor of mortality in cardiac patients, but are less effective in diabetic patients. This study aimed to determine the specific contributions of β 1 - and β 2 -adrenoceptor subtypes to chronotropic responses in type 2 diabetes in vivo, which are currently unknown. Type 2 diabetic and non-diabetic rats were implanted with radiotelemeters to measure arterial blood pressure and derive heart rate in conscious conditions. Vascular access ports were implanted to inject isoprenaline (β 1 - and β 2 -adrenoceptor agonist, 0.1-300 μg kg -1 ) in the presence of atenolol (β 1 -adrenoceptor antagonist, 2000 μg kg -1 ) or nadolol (β 1 - and β 2 -adrenoceptor agonist, 4000 μg kg -1 ) to determine the chronotropic contributions of the β-adrenoceptor subtypes. Resting heart rate was reduced in diabetic rats (388 ± 62 versus 290 ± 37 beats min -1 non-diabetic versus diabetic, P < 0.05, mean ± SD), which remained after atenolol or nadolol administration. Overall β-adrenoceptor chronotropic responsiveness was increased in diabetic rats (change in heart rate at highest dose of isoprenaline: 135 ± 66 versus 205 ± 28 beats min -1 , non-diabetic versus diabetic, P < 0.05), a difference that diminished after β 1 -adrenoceptor blockade with atenolol (change in heart rate at highest dose of isoprenaline: 205 ± 37 versus 195 ± 22 beats min -1 , non-diabetic versus diabetic, P < 0.05). In conclusion, the β 1 -adrenoceptor is the main subtype to modulate chronotropic β-adrenoceptor responses in healthy and diabetic rats. This study provides new insights into the pathological basis of dysregulation of heart rate in type 2 diabetes, which could be important for improving the current therapeutic strategies targeting diabetic chronotropic incompetence. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
Pre-transplant obesity in heart transplantation: are there predictors of worse outcomes?
Macha, Mahender; Molina, Ezequiel J; Franco, Michael; Luyun, Lisa; Gaughan, John P; McClurken, James B; Furukawa, Satoshi
2009-01-01
Morbid obesity is increasingly observed in patients being evaluated for heart transplantation and represents a relative contraindication. We sought to evaluate the influence of pre-transplant obesity on morbidity and mortality after heart transplantation. We retrospectively reviewed 90 consecutive patients with preoperative obesity (BMI > or = 30) and 90 age matched patients with normal weight (BMI 19 - 26) who underwent heart transplantation at our institution between January 1997 and December 2005. Morbidly obese patients experienced higher rates of pre-transplant diabetes (29% vs 15%, p < 0.05) and prolonged waiting time before transplantation (191.4+/-136.1 vs 117.4+/-143.2 days, p < 0.001). There were no significant differences in post-operative complications including rejection and major and minor infections. There was no difference in actuarial survival between the obese and control groups after a mean follow-up of 4.26+/-2.95 years (p = 0.513, log-rank statistic 0.452). Causes of death did not differ. Cox proportional hazard analysis revealed increased association of peripheral vascular disease (HR 31.718, p = 0.001), and pre operative inotropic support (HR 33.725, p = 0.013) with increased mortality in the obese group. This study suggests morbid obesity does not affect survival or rates of infection and rejection after heart transplantation.
Complexity of heart rate fluctuations in near-term sheep and human fetuses during sleep.
Frank, Birgit; Frasch, Martin G; Schneider, Uwe; Roedel, Marcus; Schwab, Matthias; Hoyer, Dirk
2006-10-01
We investigated how the complexity of fetal heart rate fluctuations (fHRF) is related to the sleep states in sheep and human fetuses. The complexity as a function of time scale for fetal heart rate data for 7 sheep and 27 human fetuses was estimated in rapid eye movement (REM) and non-REM sleep by means of permutation entropy and the associated Kullback-Leibler entropy. We found that in humans, fHRF complexity is higher in non-REM than REM sleep, whereas in sheep this relationship is reversed. To show this relation, choice of the appropriate time scale is crucial. In sheep fetuses, we found differences in the complexity of fHRF between REM and non-REM sleep only for larger time scales (above 2.5 s), whereas in human fetuses the complexity was clearly different between REM and non-REM sleep over the whole range of time scales. This may be due to inherent time scales of complexity, which reflect species-specific functions of the autonomic nervous system. Such differences have to be considered when animal data are translated to the human situation.
Phillips, Margaret; Flemming, Nicola; Tsintzas, Kostas
2009-08-01
To determine activity patterns and perceived barriers to exercise in ambulant people with neuromuscular disease compared with ambulatory controls. Prospective controlled parallel group design. Outpatient clinic and community. Thirteen ambulatory people with neuromuscular disease and 18 ambulatory controls. Heart rates were recorded during sedentary activity and treadmill walking at various speeds to indicate activity threshold (flex heart rate), followed by ambulatory heart rate monitoring over two weekdays and one weekend day. The EPIC-Norfolk Physical Activity Questionnaire-2 and Barriers to Physical Activity and Disability Survey were completed. Participants with neuromuscular disease were less active than controls as estimated by both the EPIC-Norfolk Physical Activity Questionnaire-2, P<0.004, and the flex heart rate method, P<0.05. The number of perceived barriers was greater in the neuromuscular group, a mean of 7 (SD 4.2) barriers, compared with mean 3 (SD 2.1) barriers for controls, P<0.05. Specific barriers differed, with the barriers of 'pain', 'lack of energy' and 'exercise is too difficult' showing the greatest discrepancy and being higher in the neuromuscular disease group. Physical activity, as determined by two different methods, was less and barriers to exercise greater in people with neuromuscular disease compared with healthy controls. Specific barriers were different in the two groups. This information could assist in the design of achievable and effective exercise programmes for people with neuromuscular disease.
Deep-Diving California Sea Lions: Are They Pushing Their Physiological Limit
2015-09-30
resting heart rate (70 bpm ) (Ponganis et al. 1997) is reached, and e) duration of and heart rate during the ascent tachycardia. If possible, heart rate...Resting heart rates were 54 + 6 beats min-1 ( bpm ), and in dives of 1-3 min, 3-5 min, and > 5 min, dive heart rates (number of beats/dive duration...were 55 + 8, 51 + 6, and 40 + bpm . As illustrated in Figs. 1 and 2, the heart rate profile was characterized by rapid development of a bradycardia
Wozniak, Jacek; Dabrowski, Rafal; Luczak, Dariusz; Kwiatkowska, Malgorzata; Musiej-Nowakowska, Elzbieta; Kowalik, Ilona; Szwed, Hanna
2009-01-01
To evaluate possible disturbances in autonomic regulation and cardiac arrhythmias in children with localized and systemic scleroderma. There were 40 children included in the study: 20 with systemic and 20 with localized scleroderma. The control group comprised 20 healthy children. In 24-hour Holter recording, the average rate of sinus rhythm was significantly higher in the groups with systemic and localized scleroderma than in the control group, but there was no significant difference between them. The variability of heart rhythm in both groups was significantly decreased. In the group with systemic scleroderma, single supraventricular ectopic beats were observed in 20% and runs were seen in 40% of patients. In the group with localized scleroderma, supraventricular single ectopic beats occurred in 35% of patients and runs in 45% of those studied. Ventricular arrhythmia occurred in 2 children with systemic scleroderma, but in 1 child, it was complex. The most frequent cardiac arrhythmias in both types of scleroderma in children were of supraventricular origin, whereas ventricular arrhythmias did not occur very often. There were no significant differences in autonomic disturbances manifesting as a higher heart rate and decreased heart rate variability between localized and systemic scleroderma.
Wick, Carson A.; Su, Jin-Jyh; McClellan, James H.; Brand, Oliver; Bhatti, Pamela T.; Buice, Ashley L.; Stillman, Arthur E.; Tang, Xiangyang; Tridandapani, Srini
2013-01-01
Seismocardiography (SCG), a representation of mechanical heart motion, may more accurately determine periods of cardiac quiescence within a cardiac cycle than the electrically derived electrocardiogram (EKG) and, thus, may have implications for gating in cardiac computed tomography. We designed and implemented a system to synchronously acquire echocardiography, EKG, and SCG data. The device was used to study the variability between EKG and SCG and characterize the relationship between the mechanical and electrical activity of the heart. For each cardiac cycle, the feature of the SCG indicating Aortic Valve Closure was identified and its time position with respect to the EKG was observed. This position was found to vary for different heart rates and between two human subjects. A color map showing the magnitude of the SCG acceleration and computed velocity was derived, allowing for direct visualization of quiescent phases of the cardiac cycle with respect to heart rate. PMID:22581141
Westfall, J M; McGloin, J
2001-05-01
Ischemic heart disease is the leading cause of death in the United States. Recent studies report inconsistent findings on the changes in the incidence of hospitalizations for ischemic heart disease. These reports have relied primarily on hospital discharge data. Preliminary data suggest that a significant percentage of patients suffering acute myocardial infarction (MI) in rural communities are transferred to urban centers for care. Patients transferred to a second hospital may be counted twice for one episode of ischemic heart disease. To describe the impact of double counting and transfer bias on the estimation of incidence rates and outcomes of ischemic heart disease, specifically acute MI, in the United States. Analysis of state hospital discharge data from Kansas, Colorado (State Inpatient Database [SID]), Nebraska, Arizona, New Jersey, Michigan, Pennsylvania, and Illinois (SID) for the years 1995 to 1997. A matching algorithm was developed for hospital discharges to determine patients counted twice for one episode of ischemic heart disease. Validation of our matching algorithm. Patients reported to have suffered ischemic heart disease (ICD9 codes 410-414, 786.5). Number of patients counted twice for one episode of acute MI. It is estimated that double count rates range from 10% to 15% for all states and increased over the 3 years. Moderate sized rural counties had the highest estimated double count rates at 15% to 20% with a few counties having estimated double count rates a high as 35% to 50%. Older patients and females were less likely to be double counted (P <0.05). Double counting patients has resulted in a significant overestimation in the incidence rate for hospitalization for acute MI. Correction of this double counting reveals a significantly lower incidence rate and a higher in-hospital mortality rate for acute MI. Transferred patients differ significantly from nontransferred patients, introducing significant bias into MI outcome studies. Double counting and transfer bias should be considered when conducting and interpreting research on ischemic heart disease, particularly in rural regions.
Sandblom, Erik; Clark, Timothy D; Hinch, Scott G; Farrell, Anthony P
2009-10-01
Some male salmonids (e.g., rainbow trout) display profound cardiovascular adjustments during sexual maturation, including cardiac growth and hypertension, and tachycardia has been observed in free-ranging male salmonids near their spawning grounds. In the present study, we investigated cardiac control, dorsal aortic blood pressure, cardiac morphometrics, and hematological variables in wild, sexually maturing sockeye salmon (Oncorhynchus nerka) with a particular aim to decipher any sex-specific differences. Routine heart rate (f(H)) was significantly higher in females (52 vs. 43 beats/min), which was due to significantly lower cholinergic tone (28 vs. 46%), because there were no differences in adrenergic tone or intrinsic heart rate between sexes. No differences in blood pressure were observed despite males possessing an 11% greater relative ventricular mass. Concomitant with higher routine heart rates, female sockeye had significantly higher levels of cortisol, testosterone, and 17beta-estradiol, whereas the level of 11-ketotestosterone was higher in males. There were no differences in hematocrit or hemoglobin concentration between the sexes. The findings of this study highlight the importance of considering sex as a variable in research fields such as conservation biology and when modeling the consequences of local and global climate change. Indeed, this study helps to provide a mechanistic basis for the significantly higher rates of female mortality observed in previous studies of wild-caught sockeye salmon.
Zaylaa, Amira; Oudjemia, Souad; Charara, Jamal; Girault, Jean-Marc
2015-09-01
This paper presents two new concepts for discrimination of signals of different complexity. The first focused initially on solving the problem of setting entropy descriptors by varying the pattern size instead of the tolerance. This led to the search for the optimal pattern size that maximized the similarity entropy. The second paradigm was based on the n-order similarity entropy that encompasses the 1-order similarity entropy. To improve the statistical stability, n-order fuzzy similarity entropy was proposed. Fractional Brownian motion was simulated to validate the different methods proposed, and fetal heart rate signals were used to discriminate normal from abnormal fetuses. In all cases, it was found that it was possible to discriminate time series of different complexity such as fractional Brownian motion and fetal heart rate signals. The best levels of performance in terms of sensitivity (90%) and specificity (90%) were obtained with the n-order fuzzy similarity entropy. However, it was shown that the optimal pattern size and the maximum similarity measurement were related to intrinsic features of the time series. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hwang, Jing-Shiang; Nadziejko, Christine; Chen, Lung Chi
2005-04-01
Normal mice (C57) and mice prone to develop atherosclerosis (ApoE-/-) were implanted with electrocardiograph (EKG), core body temperature, and motion transmitters were exposed daily for 6 h to Tuxedo, NY, concentrated ambient particles (CAPs) for 5 day/wk during the spring and summer of 2003. The series of 5-min EKG monitoring and body-temperature measurements were obtained for each animal in the CAPs and filtered air sham exposure groups. Our hypothesis was that chronic exposure could cause cumulative health effects. We used our recently developed nonparametric method to estimate the daily time periods that mean heart rates (HR), body temperature, and physical activity differed significantly between the CAPs and sham exposed group. CAPs exposure most affected heart rate between 1:30 a.m. and 4:30 a.m. With the response variables being the average heart rate, body temperature, and physical activity, we adopted a two-stage modeling approach to obtain the estimates of chronic and acute effects on the changes of these three response variables. In the first stage, a time-varying model estimated daily crude effects. In the second stage, the true means of the estimated crude effects were modeled with a polynominal function of time for chronic effects, a linear term of daily CAPs exposure concentrations for acute effects, and a random component for unknown noise. A Bayesian framework combined these two stages. There were significant decreasing patterns of HR, body temperature, and physical activity for the ApoE-/- mice over the 5 mo of CAPs exposure, with smaller and nonsignificant changes for the C57 mice. The chronic effect changes of the three response variables for ApoE-/- mice were maximal in the last few weeks. There was also a significant relationship between CAPs exposure concentration and short-term changes of heart rate in ApoE-/- mice during exposure. Response variables were also defined for examining fluctuations of 5-min heart rates within long (i.e., 3-6 h) and short time periods (i.e., approximately 15 min). The results for the ApoE-/- mice showed that heart-rate fluctuation within the longer periods increased to 1.35-fold by the end of exposure experiment, while the heart-rate fluctuation within 15 min decreased to 0.7-fold.
Cardiorespiratory interactions in humans and animals: Rhythms for life.
Elstad, Maja; O'Callaghan, Erin L; Smith, Alexander J; Ben-Tal, A; Ramchandra, Rohit
2018-03-09
The cardiorespiratory system exhibits oscillations from a range of sources. One of the most studied oscillations is heart rate variability, which is thought to be beneficial and can serve as an index of a healthy cardiovascular system. Heart rate variability is dampened in many diseases including depression, autoimmune diseases, hypertension and heart failure. Thus, understanding the interactions that lead to heart rate variability, and its physiological role, could help with prevention, diagnosis and treatment of cardiovascular diseases. In this review we consider three types of cardiorespiratory interactions; Respiratory Sinus Arrhythmia - variability in heart rate at the frequency of breathing, Cardioventilatory Coupling - synchronization between the heart beat and the onset of inspiration, and Respiratory Stroke Volume Synchronization - constant phase difference between the right and the left stroke volumes over one respiratory cycle. While the exact physiological role of these oscillations continues to be debated, the redundancies in the mechanisms responsible for its generation and its strong evolutionary conservation point to the importance of cardiorespiratory interactions. The putative mechanisms driving cardiorespiratory oscillations as well as the physiological significance of these oscillations will be reviewed. We suggest that cardiorespiratory interactions have the capacity to both dampen the variability in systemic blood flow as well as improve the efficiency of work done by the heart while maintaining physiological levels of arterial CO 2 . Given that reduction in variability is a prognostic indicator of disease, we argue that restoration of this variability via pharmaceutical or device-based approaches may be beneficial in prolonging life.
Taylor, Edwin W; Leite, Cleo A C; Sartori, Marina R; Wang, Tobias; Abe, Augusto S; Crossley, Dane A
2014-03-01
Heart rate in vertebrates is controlled by activity in the autonomic nervous system. In spontaneously active or experimentally prepared animals, inhibitory parasympathetic control is predominant and is responsible for instantaneous changes in heart rate, such as occur at the first air breath following a period of apnoea in discontinuous breathers like inactive reptiles or species that surface to air breathe after a period of submersion. Parasympathetic control, exerted via fast-conducting, myelinated efferent fibres in the vagus nerve, is also responsible for beat-to-beat changes in heart rate such as the high frequency components observed in spectral analysis of heart rate variability. These include respiratory modulation of the heartbeat that can generate cardiorespiratory synchrony in fish and respiratory sinus arrhythmia in mammals. Both may increase the effectiveness of respiratory gas exchange. Although the central interactions generating respiratory modulation of the heartbeat seem to be highly conserved through vertebrate phylogeny, they are different in kind and location, and in most species are as yet little understood. The heart in vertebrate embryos possesses both muscarinic cholinergic and β-adrenergic receptors very early in development. Adrenergic control by circulating catecholamines seems important throughout development. However, innervation of the cardiac receptors is delayed and first evidence of a functional cholinergic tonus on the heart, exerted via the vagus nerve, is often seen shortly before or immediately after hatching or birth, suggesting that it may be coordinated with the onset of central respiratory rhythmicity and subsequent breathing.
Zheng, Xia; Hu, Shen-Jiang
2006-03-01
Simvastatin, a 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitor, has long been thought to exert its benefits by reducing cholesterol synthesis, and has been shown to significantly reduce cardiovascular events and mortality in patients with or without coronary artery disease. However, it is still unknown whether acute administration of simvastatin beneficially affects the cardiac function prior or during ischemia-reperfusion. The aim of this study is to evaluate the cardioprotective effect of acute simvastatin treatment on isolated rat hearts or isolated ischemia-reperfusion hearts. Hearts were isolated from male Sprague-Dawley rats and attached to a Langendorff apparatus. The isolated hearts with or without ischemia (15 min) and reperfusion (60 min) were perfused with different concentrations of simvastatin. The parameters of cardiac function (such as left ventricular developed pressure [LVDP], +dp/dt max, and -dp/dt max), heart rate, and coronary flow were recorded. Simvastatin (3-30 micromol/l) significantly increased LVDP, +dp/dt max, and -dp/dt max in isolated rat hearts perfused for 60 min. Heart rate was depressed by 30 micromol/l simvastatin and the coronary flow was increased by 10 and 30 micromol/l simvastatin. At a concentration of 100 micromol/l simvastatin, worsening of heart function and subsequent cardiac arrest occurred. Administration of simvastatin (3-30 micromol/l) significantly preserved cardiac function detected by LVDP, +dp/dt max, and -dp/dt max in the isolated ischemia/reperfused (15/60 min) rat hearts. Simvastatin also significantly decreased heart rate at 30 micromol/l, and increased coronary flow at 10 and 30 micromol/l in these rat hearts. However, the protective effect of simvastatin reverted to increased damage at 100 micromol/l. Only 3 micromol/l simvastatin pretreatment before 15/60 min ischemia-reperfusion altered LVDP, +dp/dt max, and -dp/dt max. Both heart rate and coronary flow were unaltered after simvastatin pretreatment. Since simvastatin at a concentration lower than 100 micromol/l exerted beneficial effects on cardiac function in isolated perfused rat hearts, it could be applied just after myocardial ischemia and reperfusion.
Shah, Ankit B; Patel, Jignesh K; Rafiei, Matthew; Morrissey, Ryan P; Kittleson, Michelle M; Kobashigawa, Jon A
2013-01-01
Cardiac denervation following transplantation has a variable effect on heart rate (HR), and the consequence of this is not known. We examined the impact of first-year HR on five-yr outcomes after heart transplant. We evaluated 544 heart transplant recipients from 1994 to 2008. Patients were divided into groups by mean first-year HR: group 1, HR < 90 (mean 85.0 ± 4.3); group 2, 90 ≤ HR < 110 (mean 97.8 ± 4.9); group 3, HR ≥ 110 (mean 111.5 ± 1.8). Endpoints included one-yr freedom from treated rejection, five-yr survival, five-yr freedom from cardiac allograft vasculopathy (CAV), and five-yr freedom from non-fatal major adverse cardiac events (NF-MACE). One-yr freedom from treated rejection, five-yr survival and freedom from CAV were not significantly different between groups. Five-yr freedom from NF-MACE was significantly lower in group 3 compared with group 2, 69% vs. 91%, p < 0.01, mainly due to higher prevalence of congestive heart failure (CHF) in group 3 over five yr. Mean first-year HR does not provide prognostic significance for one-yr freedom from treated rejection, five-yr survival or development of CAV five yr after heart transplant. These results suggest that HR post-heart transplantation does not affect long-term outcomes, but high first-year HRs may be associated with new-onset CHF. © 2013 John Wiley & Sons A/S.
Long‐term Cardiovascular Risks Associated With an Elevated Heart Rate: The Framingham Heart Study
Ho, Jennifer E.; Larson, Martin G.; Ghorbani, Anahita; Cheng, Susan; Coglianese, Erin E.; Vasan, Ramachandran S.; Wang, Thomas J.
2014-01-01
Background Higher heart rate has been associated with an adverse prognosis, but most prior studies focused on individuals with known cardiovascular disease or examined a limited number of outcomes. We sought to examine the association of baseline heart rate with both fatal and nonfatal outcomes during 2 decades of follow‐up. Methods and Results Our study included 4058 Framingham Heart Study participants (mean age 55 years, 56% women). Cox models were performed with multivariable adjustment for clinical risk factors and physical activity. A total of 708 participants developed incident cardiovascular disease (303 heart failure, 343 coronary heart disease, and 216 stroke events), 48 received a permanent pacemaker, and 1186 died. Baseline heart rate was associated with incident cardiovascular disease (hazard ratio [HR] 1.15 per 1 SD [11 bpm] increase in heart rate, 95% CI 1.07 to 1.24, P=0.0002), particularly heart failure (HR 1.32, 95% CI 1.18 to 1.48, P<0.0001). Higher heart rate was also associated with higher all‐cause (HR 1.17, 95% CI 1.11 to 1.24, P<0.0001) and cardiovascular mortality (HR 1.18, 95% CI 1.04 to 1.33, P=0.01). Spline analyses did not suggest a lower threshold beyond which the benefit of a lower heart rate abated or increased. In contrast, individuals with a higher heart rate had a lower risk of requiring permanent pacemaker placement (HR 0.55, 95% CI 0.38 to 0.79, P=0.001). Conclusions Individuals with a higher heart rate are at elevated long‐term risk for cardiovascular events, in particular, heart failure, and all‐cause death. On the other hand, a higher heart rate is associated with a lower risk of future permanent pacemaker implantation. PMID:24811610
Goudkamp, Jacqueline E; Seebacher, Frank; Ahern, Mark; Franklin, Craig E
2004-07-01
Differential heart rates during heating and cooling (heart rate hysteresis) are an important thermoregulatory mechanism in ectothermic reptiles. We speculate that heart rate hysteresis has evolved alongside vascularisation, and to determine whether this phenomenon occurs in a lineage with vascularised circulatory systems that is phylogenetically distant from reptiles, we measured the response of heart rate to convective heat transfer in the Australian freshwater crayfish, Cherax destructor. Heart rate during convective heating (from 20 to 30 degrees C) was significantly faster than during cooling for any given body temperature. Heart rate declined rapidly immediately following the removal of the heat source, despite only negligible losses in body temperature. This heart rate 'hysteresis' is similar to the pattern reported in many reptiles and, by varying peripheral blood flow, it is presumed to confer thermoregulatory benefits particularly given the thermal sensitivity of many physiological rate functions in crustaceans.
G protein-coupled estrogen receptor regulates embryonic heart rate in zebrafish
Romano, Shannon N.; Edwards, Hailey E.; Ryan, Kevin J.
2017-01-01
Estrogens act by binding to estrogen receptors alpha and beta (ERα, ERβ), ligand-dependent transcription factors that play crucial roles in sex differentiation, tumor growth and cardiovascular physiology. Estrogens also activate the G protein-coupled estrogen receptor (GPER), however the function of GPER in vivo is less well understood. Here we find that GPER is required for normal heart rate in zebrafish embryos. Acute exposure to estrogens increased heart rate in wildtype and in ERα and ERβ mutant embryos but not in GPER mutants. GPER mutant embryos exhibited reduced basal heart rate, while heart rate was normal in ERα and ERβ mutants. We detected gper transcript in discrete regions of the brain and pituitary but not in the heart, suggesting that GPER acts centrally to regulate heart rate. In the pituitary, we observed gper expression in cells that regulate levels of thyroid hormone triiodothyronine (T3), a hormone known to increase heart rate. Compared to wild type, GPER mutants had reduced levels of T3 and estrogens, suggesting pituitary abnormalities. Exposure to exogenous T3, but not estradiol, rescued the reduced heart rate phenotype in gper mutant embryos, demonstrating that T3 acts downstream of GPER to regulate heart rate. Using genetic and mass spectrometry approaches, we find that GPER regulates maternal estrogen levels, which are required for normal embryonic heart rate. Our results demonstrate that estradiol plays a previously unappreciated role in the acute modulation of heart rate during zebrafish embryonic development and suggest that GPER regulates embryonic heart rate by altering maternal estrogen levels and embryonic T3 levels. PMID:29065151
G protein-coupled estrogen receptor regulates embryonic heart rate in zebrafish.
Romano, Shannon N; Edwards, Hailey E; Souder, Jaclyn Paige; Ryan, Kevin J; Cui, Xiangqin; Gorelick, Daniel A
2017-10-01
Estrogens act by binding to estrogen receptors alpha and beta (ERα, ERβ), ligand-dependent transcription factors that play crucial roles in sex differentiation, tumor growth and cardiovascular physiology. Estrogens also activate the G protein-coupled estrogen receptor (GPER), however the function of GPER in vivo is less well understood. Here we find that GPER is required for normal heart rate in zebrafish embryos. Acute exposure to estrogens increased heart rate in wildtype and in ERα and ERβ mutant embryos but not in GPER mutants. GPER mutant embryos exhibited reduced basal heart rate, while heart rate was normal in ERα and ERβ mutants. We detected gper transcript in discrete regions of the brain and pituitary but not in the heart, suggesting that GPER acts centrally to regulate heart rate. In the pituitary, we observed gper expression in cells that regulate levels of thyroid hormone triiodothyronine (T3), a hormone known to increase heart rate. Compared to wild type, GPER mutants had reduced levels of T3 and estrogens, suggesting pituitary abnormalities. Exposure to exogenous T3, but not estradiol, rescued the reduced heart rate phenotype in gper mutant embryos, demonstrating that T3 acts downstream of GPER to regulate heart rate. Using genetic and mass spectrometry approaches, we find that GPER regulates maternal estrogen levels, which are required for normal embryonic heart rate. Our results demonstrate that estradiol plays a previously unappreciated role in the acute modulation of heart rate during zebrafish embryonic development and suggest that GPER regulates embryonic heart rate by altering maternal estrogen levels and embryonic T3 levels.
Monitoring nocturnal heart rate with bed sensor.
Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M
2014-01-01
This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.
Diminution of Heart Rate Variability in Bipolar Depression
Hage, Brandon; Britton, Briana; Daniels, David; Heilman, Keri; Porges, Stephen W.; Halaris, Angelos
2017-01-01
Autonomic nervous system (ANS) dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV) provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD) patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia) was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20) than controls (ln = 5.50) (p < 0.01). Baseline heart period was significantly shorter (i.e., faster heart rate) in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients. PMID:29270399
Kim, Dae-Young; Seo, Byoung-Do; Choi, Pan-Am
2014-04-01
[Purpose] This study was conducted to determine the influence of Taekwondo as security martial arts training on anaerobic threshold, cardiorespiratory fitness, and blood lactate recovery. [Subjects and Methods] Fourteen healthy university students were recruited and divided into an exercise group and a control group (n = 7 in each group). The subjects who participated in the experiment were subjected to an exercise loading test in which anaerobic threshold, value of ventilation, oxygen uptake, maximal oxygen uptake, heart rate, and maximal values of ventilation / heart rate were measured during the exercise, immediately after maximum exercise loading, and at 1, 3, 5, 10, and 15 min of recovery. [Results] At the anaerobic threshold time point, the exercise group showed a significantly longer time to reach anaerobic threshold. The exercise group showed significantly higher values for the time to reach VO2max, maximal values of ventilation, maximal oxygen uptake and maximal values of ventilation / heart rate. Significant changes were observed in the value of ventilation volumes at the 1- and 5-min recovery time points within the exercise group; oxygen uptake and maximal oxygen uptake were significantly different at the 5- and 10-min time points; heart rate was significantly different at the 1- and 3-min time points; and maximal values of ventilation / heart rate was significantly different at the 5-min time point. The exercise group showed significant decreases in blood lactate levels at the 15- and 30-min recovery time points. [Conclusion] The study results revealed that Taekwondo as a security martial arts training increases the maximal oxygen uptake and anaerobic threshold and accelerates an individual's recovery to the normal state of cardiorespiratory fitness and blood lactate level. These results are expected to contribute to the execution of more effective security services in emergencies in which violence can occur.
Context Specificity of the ANS Stress Response during Two Regrouping Experiments in Goats
Patt, Antonia; Gygax, Lorenz; Wechsler, Beat; Hillmann, Edna; Langbein, Jan; Keil, Nina M.
2016-01-01
The aim of this study was to analyze whether the activity of the autonomic nervous system (ANS) differs between two regrouping procedures in goats, which would indicate stimulus specificity of these stressors. Applying two regrouping procedures, we evaluated heart rate and heart rate variability (RMSSD, SDNN, and RMSSD/SDNN). The two regrouping procedures were (1) introduction of individual goats into established groups (“introduction experiment”) and (2) temporary separation and subsequent reintegration of individuals from/into their group with two levels of contact during separation (“separation experiment”). In the “introduction experiment,” the heart rate of introduced goats while lying decreased continuously from an average 78 to 68 beats/min from before the introduction to the last day of the introduction period. Inversely, RMSSD increased continuously from 41 to 62 ms, which, on its own, would indicate an adaptation to the situation. During the “separation experiment,” heart rate while lying was higher when goats were separated in the “acoustic contact treatment” (82 beats/min on average) compared with the “restricted physical contact treatment” (75 beats/min on average). This difference reflected a higher level of arousal during the “acoustic contact treatment.” However, heart rate activity did not allow detecting effects of separation or reintegration. Even though it can be assumed that both the separation and introduction of goats are stressful for goats, the ANS reactions observed in this study differed between the two management procedures indicating that the ANS activation was specific to each situation. In addition, we discuss the ANS results in context with earlier findings of variables of the hypothalamic pituitary adrenal (HPA) axis (fecal cortisol metabolites) and behavior (lying and feeding). As correspondence between ANS, HPA, and behavioral reactions was limited both within and across experiments, the results of this study underline the concept that stress response patterns are context specific. PMID:27551679
Dantas, Mara de Oliveira Rodrigues Luiz; Auler, José Otávio Costa; Andrade, Claudia Regina Furquim de
2010-01-01
Swallowing evaluation of older individuals with coronary disease referred to heart surgery. To identify the characteristics of the swallowing function in older individuals referred to myocardial revascularization surgery (MR), using an evaluating protocol composed by a water test, cervical auscultation and pulse oximetry. The Assessment Protocol for Dysphagia Risk through a Combined Swallowing test and Vital Signs monitoring was used (PADTC)--measurements of HR and SpO2 (heart rate and oxygen saturation), water swallowing test with 1, 3, 5, 10, 15 e 20 ml, measurement of respiratory rate and cervical auscultation. The electronic stethoscope was used to analyze the number of swallows, response time and swallowing sound classification. In the Research Group (RG) older individuals with heart disease who were referred to MR were included. In the Control Group (CG) healthy older individuals were included. 38 older individuals were evaluated in the RG (mean age 68 years). In the CG, 30 older individuals were evaluated (mean age 70 years). There was a significant difference for the swallowing response time in older individuals with heart disease who presented HR below 60: swallowing response was shorter for 3 ml, 10 ml, 15 ml e 20 ml. HR was lower for individuals with heart disease. No significant difference was found between the groups for the other analyzed parameters. Older individuals with heart disease presented differences in the swallowing function when compared to healthy older individuals. Older individuals with heart disease presented alterations in the temporal coordination between breathing and swallowing, thus indicating risk for dysphagia.
A call to action: bold ideas from the Minnesota Women's Heart Summit.
Ali, Nora; Lindquist, Ruth; Boucher, Jackie L; Witt, Dawn; Ambroz, Teresa; Konety, Suma H; Luepker, Russell; Windenburg, Denise; Hayes, Sharonne N
2012-05-01
Minnesota has the lowest overall coronary heart disease mortality rate in the United States. Yet disparities between men and women persist with regard to prevention, detection, and treatment. This has led to a gender gap not only in terms of care but also in survival rates. In an effort to better understand and close the gender gap, the Minneapolis Heart Institute, the Minneapolis Heart Institute Foundation, the University of Minnesota, and Mayo Clinic hosted a multidisciplinary Women's Heart Summit in April 2010. The goals of the summit were to stimulate dialogue and devise strategies to eliminate untimely deaths of women from heart disease. Summit participants were asked to contribute suggestions--called "Bold Ideas"--to address sex-based differences in the prevention, detection, and treatment of heart disease. Ideas were categorized according to three themes: educational programming, modifications to the health care system, and government involvement and funding. From these, several solutions emerged: 1) Involve obstetric/gynecologic physicians in providing heart-health education; 2) involve mid-level providers (midwives and other advanced practice women's health care providers) and other health professionals in women's heart health education, and 3) maximize the use of social media and online newsfeeds to raise awareness of heart disease in women. This article summarizes the discussion of the main ideas submitted by summit participants.
Dreyer, Rachel P; Dharmarajan, Kumar; Hsieh, Angela F; Welsh, John; Qin, Li; Krumholz, Harlan M
2017-05-01
Women have an increased risk of rehospitalization in the immediate postdischarge period; however, few studies have determined how readmission risk dynamically changes on a day-to-day basis over the full year after hospitalization by sex and how these differences compare with the risk for mortality. We identified >3 000 000 hospitalizations of patients with a principal discharge diagnosis of heart failure, acute myocardial infarction, or pneumonia and estimated sex differences in the daily risk of rehospitalization/death 1 year after discharge from a population of Medicare fee-for-service beneficiaries aged 65 years and older. We calculated the (1) time required for adjusted rehospitalization/mortality risks to decline 50% from maximum values after discharge, (2) time required for the adjusted readmission risk to approach plateau periods of minimal day-to-day change, and (3) extent to which adjusted risks are greater among recently hospitalized patients versus Medicare patients. We identified 1 392 289, 530 771, and 1 125 231 hospitalizations for heart failure, acute myocardial infarction, and pneumonia, respectively. The adjusted daily risk of rehospitalization varied by admitting condition (hazard rate ratio for women versus men, 1.10 for acute myocardial infarction; hazard rate ratio, 1.04 for heart failure; and hazard rate ratio, 0.98 for pneumonia). However, for all conditions, the adjusted daily risk of death was higher among men versus women (hazard rate ratio women versus with men, <1). For both sexes, there was a similar timing of peak daily risk, half daily risk, and reaching plateau. Although the association of sex with daily risk of rehospitalization varies across conditions, women are at highest risk after discharge for acute myocardial infarction. Future studies should focus on understanding the determinants of sex differences in rehospitalization risk among conditions. © 2017 American Heart Association, Inc.
Zarei, M; Ghoddusi, J; Sharifi, E; Forghani, M; Afkhami, F; Marouzi, Parviz
2012-10-01
To compare the efficacy of supplemental anaesthesia using periodontal ligament injections (PDL) and intraosseous injections with the X-Tip system in terms of the measured heart rate and patient reported pain level. In this single-blind randomized clinical trial, 40 patients (22 women, 18 men) with irreversible pulpitis who had experienced unsuccessful pain management by inferior alveolar nerve block with 2% lidocaine and 1 : 100 000 epinephrine were selected. Patients were divided equally and randomly into two groups. Supplementary anaesthesia was provided through intraosseous injection with the X-Tip system (X-Tip group) or by PDL injection (PDL group). After each step of injection, pain severity was assessed using a visual analogue scale. Patient heart rate was recorded with a pulse oximeter. Data were coded and analysed using Mann-Whitney U-test with SPSS (version 16) software. Anaesthetic success was obtained in 100% of X-Tip and 70% of PDL group patients after the first supplemental injection. Compared with the first PDL injection, the first intraosseous injection resulted in a significant increase in heart rate (P = 0.001); however, this increase was short-lived (mean increase: 9-10 beats per min). No significant difference in heart rate or anaesthesia success was observed between men and women. Intraosseous injection using the X-Tip system was more effective than PDL injection as a supplementary anaesthetic for pulpectomy in mandibular molars or second premolars. However, the former resulted in a transient increase in heart rate. © 2012 International Endodontic Journal.
Development of electrocardiogram intervals during growth of FVB/N neonate mice
2010-01-01
Background Electrocardiography remains the best diagnostic tool and therapeutic biomarker for a spectrum of pediatric diseases involving cardiac or autonomic nervous system defects. As genetic links to these disorders are established and transgenic mouse models produced in efforts to understand and treat them, there is a surprising lack of information on electrocardiograms (ECGs) and ECG abnormalities in neonate mice. This is likely due to the trauma and anaesthesia required of many legacy approaches to ECG recording in mice, exacerbated by the fragility of many mutant neonates. Here, we use a non-invasive system to characterize development of the heart rate and electrocardiogram throughout the growth of conscious neonate FVB/N mice. Results We examine ECG waveforms as early as two days after birth. At this point males and females demonstrate comparable heart rates that are 50% lower than adult mice. Neonatal mice exhibit very low heart rate variability. Within 12 days of birth PR, QRS and QTc interval durations are near adult values while heart rate continues to increase until weaning. Upon weaning FVB/N females quickly develop slower heart rates than males, though PR intervals are comparable between sexes until a later age. This suggests separate developmental events may contribute to these gender differences in electrocardiography. Conclusions We provide insight with a new level of detail to the natural course of heart rate establishment in neonate mice. ECG can now be conveniently and repeatedly used in neonatal mice. This should serve to be of broad utility, facilitating further investigations into development of a diverse group of diseases and therapeutics in preclinical mouse studies. PMID:20735846
Adams, Jenny; Schneider, Jonna; Hubbard, Matthew; McCullough-Shock, Tiffany; Cheng, Dunlei; Simms, Kay; Hartman, Julie; Hinton, Paul; Strauss, Danielle
2010-01-01
This study was designed to measure the functional capacity of healthy subjects during strenuous simulated police tasks, with the goal of developing occupation-specific training for cardiac rehabilitation of police officers. A calibrated metabolic instrument and an oxygen consumption data collection mask were used to measure the oxygen consumption and heart rates of 30 Dallas Police Academy officers and cadets as they completed an 8-event obstacle course that simulated chasing, subduing, and handcuffing a suspect. Standard target heart rates (85% of age-predicted maximum heart rate, or 0.85 x [220 - age]) and metabolic equivalents (METs) were calculated; a matched-sample t test based on differences between target and achieved heart rate and MET level was used for statistical analysis. Peak heart rates during the obstacle course simulation were significantly higher than the standard target heart rates (those at which treadmill stress tests in physicians' offices are typically stopped) (t(29) = 12.81, P < 0.001) and significantly higher than the suggested maximum of 150 beats/min during cardiac rehabilitation training (t(29) = 17.84, P < 0.001). Peak MET levels during the obstacle course simulation were also significantly higher than the goal level (8 METs) that patients typically achieve in a cardiac rehabilitation program (t(29) = 14.73, P < 0.001). We conclude that police work requires a functional capacity greater than that typically attained in traditional cardiac rehabilitation programs. Rehabilitation professionals should consider performing maximal stress tests and increasing the intensity of cardiac rehabilitation workouts to effectively train police officers who have had a cardiac event.
Self-esteem levels and cardiovascular and inflammatory responses to acute stress.
O'Donnell, Katie; Brydon, Lena; Wright, Caroline E; Steptoe, Andrew
2008-11-01
Acute mental stress tests have helped to clarify the pathways through which psychosocial factors are linked to disease risk. This methodology is now being used to investigate potentially protective psychosocial factors. We investigated whether global self-esteem might buffer cardiovascular and inflammatory responses to acute stress. One hundred and one students completed the Rosenberg Self-Esteem Scale. Heart rate and heart rate variability (HRV) were recorded for 5 min periods at baseline, during two mental stress tasks, (a speech and a color-word task) and 10, 25 and 40 min into a recovery period. Plasma levels of tumor-necrosis factor-alpha (TNF-alpha), interleukin-6 (IL-6) and interleukin-1 receptor antagonist (IL-1Ra) were assessed at baseline, immediately post-stress and after 45 min recovery. Repeated measures analysis of variance demonstrated that heart rate levels were lower across all time points in those with high self-esteem, although heart rate reactivity to stress was not related to self-esteem. There were no differences in baseline HRV, TNF-alpha, IL-6 or IL-1Ra. Multiple linear regressions revealed that greater self-esteem was associated with a smaller reduction in heart rate variability during the speech task, but not the color-word task. Greater self-esteem was associated with smaller TNF-alpha and IL-1Ra responses immediately following acute stress and smaller IL-1Ra responses at 45 min post-stress. In conclusion, global self-esteem is associated with lower heart rate and attenuated HRV and inflammatory responses to acute stress. These responses could be processes through which self-esteem protects against the development of disease.
Portable electrocardiogram device using Android smartphone.
Brucal, S G E; Clamor, G K D; Pasiliao, L A O; Soriano, J P F; Varilla, L P M
2016-08-01
Portable electrocardiogram (ECG) capturing device can be interfaced to a smart phone installed with an android-based application (app). This app processes and analyses the data sent by the device to provide an interpretation of the patient/user's heart current condition (e.g.: beats per minute, heart signal waveform, R-R interval). The ECG recorded by the app is stored in the smart phone's Secure Digital (SD) card and cloud storage which can be accessed remotely by a physician to aid in providing medical diagnosis. The project aims to help patients living at a far distance from hospitals and experience difficulty in consulting their physician for regular check-ups, and assist doctors in regularly monitoring their patient's heart condition. The hardware data acquisition device and software application were subjected to trials in a clinic with volunteer-patients to measure the ECG and heart rate, data saving speed on the SD card, success rate of the saved data and uploaded file. Different ECG tests using the project prototype were done for 12 patients/users and yielded a reading difference of 7.61% in an R-R interval reading and 5.35% in heart rate reading as compared with the cardiologist's conventional 12-electrode ECG machine. Using the developed ECG device, it took less than 5 seconds to save ECG reading using SD card and approximately 2 minutes to upload via cloud.
Increased pulmonary transit times in asymptomatic dogs with mitral regurgitation.
Lord, Peter; Eriksson, Anders; Häggström, Jens; Järvinen, Anna-Kaisa; Kvart, Clarence; Hansson, Kerstin; Maripuu, Enn; Mäkelä, Olli
2003-01-01
Pulmonary transit time (PTT) normalized to heart rate (nPTT) is a measure of the pulmonary blood volume (PBV) to stroke volume ratio (PBV/SV). It is an index of cardiac performance. To determine the effect of compensated mitral regurgitation (CMR) and decompensated mitral regurgitation (DMR) caused by valvular endocardiosis on the index nPTT, we measured nPTT by first-pass radionuclide angiocardiography and ECG in 13 normal dogs, 18 dogs with CMR, and 13 dogs with DMR. PTT was measured as time between onset of appearance of activity at the pulmonary trunk and the left atrium. In the normal dogs, the relationship between PTT and mean R-R interval (mRR) was PTT = 4.08 x mRR + 0.15 (R2 = 0.71). Normal nPTT was 4.4 +/- 0.6 (SD) (range. 3.6-5.3). in CMR, 6.3 +/- 1.6 (SD) (range, 4.0-9.7). and in DMR, 11.9 +/- 3.4 (SD) (range, 8.0-18.8). The differences among all groups were significant. Heart rates were 110 +/- 22 bpm in normal dogs, 111 +/- 20 in dogs with CMR, and 144 +/- 18 in dogs with DMR (P < .001 for difference between DMR group and normal and CMR groups). Increased nPTT in CMR indicates preclinical heart pump dysfunction. Heart rate-normalized pulmonary transit times may be a useful index of heart function in mitral regurgitation.
The relationship between sexual concordance and interoception in anxious and nonanxious women.
Suschinsky, Kelly D; Lalumière, Martin L
2014-04-01
Sexual concordance refers to the association between physiological and self-reported sexual arousal. Women typically exhibit lower sexual concordance scores than men. There is also a sex difference in interoception--awareness of (nonsexual) physiological states or responses--such that women, compared with men, tend to be less aware of and less accurate at detecting changes in their physiological responses. Women with anxiety problems tend to have better interoceptive abilities than nonanxious women. To investigate whether women's lower sexual concordance is associated with interoception using a sample likely to show high variation in interoceptive abilities. Sixteen anxious and 15 nonanxious women were presented with twelve 90 seconds sexual and nonsexual film clips while their genital response, heart rate, and respiration rate were measured. A heartbeat mental tracking task was also employed. Genital response was measured with a vaginal photoplethysmograph. Heart rate was measured with an electrocardiogram and respiration rate with a thermistor. Participants estimated their physiological responses after each film. A mental tracking task was also used to assess participants' awareness of heart rate. Within-subject correlations were computed for each physiological/self-reported response combination. Overall, sexual concordance (i.e., the correlation between genital responses and perceptions of genital response) was not significantly associated with heart rate awareness or respiration rate awareness. Anxious women did not exhibit significantly higher sexual concordance or heart rate awareness than nonanxious women; the nonanxious women actually exhibited higher respiration rate awareness. The results suggest that sexual concordance may be a distinct phenomenon from interoception and in need of its own explanation. © 2013 International Society for Sexual Medicine.
Unobtrusive monitoring of heart rate using a cost-effective speckle-based SI-POF remote sensor
NASA Astrophysics Data System (ADS)
Pinzón, P. J.; Montero, D. S.; Tapetado, A.; Vázquez, C.
2017-03-01
A novel speckle-based sensing technique for cost-effective heart-rate monitoring is demonstrated. This technique detects periodical changes in the spatial distribution of energy on the speckle pattern at the output of a Step-Index Polymer Optical Fiber (SI-POF) lead by using a low-cost webcam. The scheme operates in reflective configuration thus performing a centralized interrogation unit scheme. The prototype has been integrated into a mattress and its functionality has been tested with 5 different patients lying on the mattress in different positions without direct contact with the fiber sensing lead.
Hoeker, Gregory S.; Hood, Ashleigh R.; Katra, Rodolphe P.; Poelzing, Steven; Pogwizd, Steven M.
2014-01-01
Cardioprotection in females, as observed in the setting of heart failure, has been attributed to sex differences in intracellular calcium handling and its modulation by β-adrenergic signaling. However, further studies examining sex differences in β-adrenergic responsiveness have yielded inconsistent results and have mostly been limited to studies of contractility, ion channel function, or calcium handling alone. Given the close interaction of the action potential (AP) and intracellular calcium transient (CaT) through the process of excitation-contraction coupling, the need for studies exploring the relationship between agonist-induced AP and calcium handling changes in female and male hearts is evident. Thus, the aim of this study was to use optical mapping to examine sex differences in ventricular APs and CaTs measured simultaneously from Langendorff-perfused hearts isolated from naïve adult rabbits during β-adrenergic stimulation. The non-selective β-agonist isoproterenol (Iso) decreased AP duration (APD90), CaT duration (CaD80), and the decay constant of the CaT (τ) in a dose-dependent manner (1–316.2 nM), with a plateau at doses ≥31.6 nM. The Iso-induced changes in APD90 and τ (but not CaD80) were significantly smaller in female than male hearts. These sex differences were more significant at faster (5.5 Hz) than resting rates (3 Hz). Treatment with Iso led to the development of spontaneous calcium release (SCR) with a dose threshold of 31.6 nM. While SCR occurrence was similar in female (49%) and male (53%) hearts, the associated ectopic beats had a lower frequency of occurrence (16% versus 40%) and higher threshold (100 nM versus 31.6 nM) in female than male hearts (p<0.05). In conclusion, female hearts had a decreased capacity to respond to β-adrenergic stimulation, particularly under conditions of increased demand (i.e. faster pacing rates and “maximal” levels of Iso effects), however this reduced β-adrenergic responsiveness of female hearts was associated with reduced arrhythmic activity. PMID:25340795
Estimation of Measurement Characteristics of Ultrasound Fetal Heart Rate Monitor
NASA Astrophysics Data System (ADS)
Noguchi, Yasuaki; Mamune, Hideyuki; Sugimoto, Suguru; Yoshida, Atsushi; Sasa, Hidenori; Kobayashi, Hisaaki; Kobayashi, Mitsunao
1995-05-01
Ultrasound fetal heart rate monitoring is very useful to determine the status of the fetus because it is noninvasive. In order to ensure the accuracy of the fetal heart rate (FHR) obtained from the ultrasound Doppler data, we measure the fetal electrocardiogram (ECG) directly and obtain the Doppler data simultaneously. The FHR differences of the Doppler data from the direct ECG data are concentrated at 0 bpm (beats per minute), and are practically symmetrical. The distribution is found to be very close to the Student's t distribution by the test of goodness of fit with the chi-square test. The spectral density of the FHR differences shows the white noise spectrum without any dominant peaks. Furthermore, the f-n (n>1) fluctuation is observed both with the ultrasound Doppler FHR and with the direct ECG FHR. Thus, it is confirmed that the FHR observation and observation of the f-n (n>1) fluctuation using the ultrasound Doppler FHR are as useful as the direct ECG.
Latham, Daniel T; Hill, Grant M; Petray, Clayre K
2013-04-01
The purpose of this study was to assess whether a treadmill mile is an acceptable FitnessGram Test substitute for the traditional one-mile run for middle school boys and girls. Peak heart rate and perceived physical exertion of the participants were also measured to assess students' effort. 48 boys and 40 girls participated, with approximately 85% classified as Hispanic. Boys' mean time for the traditional one-mile run, as well as peak heart rate and perceived exertion, were statistically significantly faster and higher, respectively, than for the treadmill mile. Girls' treadmill mile times were not statistically significantly different from the traditional one-mile run. There were no statistically significant differences for girl's peak heart rate or perceived exertion. The results suggest that providing middle school students a choice of completing the FitnessGram mile run in either traditional one-mile run or treadmill one-mile format may positively affect performance.
Introducing a novel mechanism to control heart rate in the ancestral Pacific hagfish.
Wilson, Christopher M; Roa, Jinae N; Cox, Georgina K; Tresguerres, Martin; Farrell, Anthony P
2016-10-15
Although neural modulation of heart rate is well established among chordate animals, the Pacific hagfish (Eptatretus stoutii) lacks any cardiac innervation, yet it can increase its heart rate from the steady, depressed heart rate seen in prolonged anoxia to almost double its normal normoxic heart rate, an almost fourfold overall change during the 1-h recovery from anoxia. The present study sought mechanistic explanations for these regulatory changes in heart rate. We provide evidence for a bicarbonate-activated, soluble adenylyl cyclase (sAC)-dependent mechanism to control heart rate, a mechanism never previously implicated in chordate cardiac control. © 2016. Published by The Company of Biologists Ltd.
Cubbon, Richard M; Ruff, Naomi; Groves, David; Eleuteri, Antonio; Denby, Christine; Kearney, Lorraine; Ali, Noman; Walker, Andrew M N; Jamil, Haqeel; Gierula, John; Gale, Chris P; Batin, Phillip D; Nolan, James; Shah, Ajay M; Fox, Keith A A; Sapsford, Robert J; Witte, Klaus K; Kearney, Mark T
2016-02-01
We aimed to define the prognostic value of the heart rate range during a 24 h period in patients with chronic heart failure (CHF). Prospective observational cohort study of 791 patients with CHF associated with left ventricular systolic dysfunction. Mode-specific mortality and hospitalisation were linked with ambulatory heart rate range (AHRR; calculated as maximum minus minimum heart rate using 24 h Holter monitor data, including paced and non-sinus complexes) in univariate and multivariate analyses. Findings were then corroborated in a validation cohort of 408 patients with CHF with preserved or reduced left ventricular ejection fraction. After a mean 4.1 years of follow-up, increasing AHRR was associated with reduced risk of all-cause, sudden, non-cardiovascular and progressive heart failure death in univariate analyses. After accounting for characteristics that differed between groups above and below median AHRR using multivariate analysis, AHRR remained strongly associated with all-cause mortality (HR 0.991/bpm increase in AHRR (95% CI 0.999 to 0.982); p=0.046). AHRR was not associated with the risk of any non-elective hospitalisation, but was associated with heart-failure-related hospitalisation. AHRR was modestly associated with the SD of normal-to-normal beats (R(2)=0.2; p<0.001) and with peak exercise-test heart rate (R(2)=0.33; p<0.001). Analysis of the validation cohort revealed AHRR to be associated with all-cause and mode-specific death as described in the derivation cohort. AHRR is a novel and readily available prognosticator in patients with CHF, which may reflect autonomic tone and exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Beider, Shay; Boulanger, Karen T; Joshi, Milind; Pan, Yann Ping; Chang, Ruey-Kang R
2010-09-28
Congenital heart disease, a common and serious birth defect, affects 8 per 1000 live-born infants. Decreased exercise capacity and development of obesity is common in this population. These children may benefit from therapies, such as massage therapy, that could enhance cardiovascular and skeletal muscle function when they exercise. A pilot study conducted at the pediatric cardiology clinic of the Mattel Children's Hospital of the University of California-Los Angeles examined the safety and feasibility of measuring the effects of pre-exercise massage on exercise performance and cardiopulmonary response in children with and without heart disease. SIXTEEN CHILDREN (MEAN AGE: 9.2 ± 2.2 years) participated in the study. Ten participants had various forms of heart disease, and six children were healthy. A female certified massage therapist with specialized training in pediatric massage provided a 30-minute massage to the participants. Using a standard protocol, each participant underwent two exercise tests: one test with and one without pre-exercise massage. Heart rate, blood pressure, and oxygen uptake (VO(2)) were measured in the participants. All recruited participants completed the study. No adverse events occurred during any of the exercise tests or massage sessions. Measurements during exercise with or without a preceding massage were compared, and the pre-exercise massage condition yielded a significantly higher heart rate and higher minute ventilation. Measurements during exercise in children with heart disease and in healthy participants showed no significant differences in peak heart rate, blood pressure, peak VO(2), peak work rate, minute ventilation, or respiratory quotient. In this study, peak heart rate, peak VO(2), and peak minute ventilation were higher when children received a massage before exercise testing. Larger studies will be needed to investigate the strength of this finding. Future studies should include measurements of anxiety and psychological factors in addition to cardiopulmonary measures.
Cardiovascular responses associated with daily walking in subacute stroke.
Prajapati, Sanjay K; Mansfield, Avril; Gage, William H; Brooks, Dina; McIlroy, William E
2013-01-01
Despite the importance of regaining independent ambulation after stroke, the amount of daily walking completed during in-patient rehabilitation is low. The purpose of this study is to determine if (1) walking-related heart rate responses reached the minimum intensity necessary for therapeutic aerobic exercise (40%-60% heart rate reserve) or (2) heart rate responses during bouts of walking revealed excessive workload that may limit walking (>80% heart rate reserve). Eight individuals with subacute stroke attending in-patient rehabilitation were recruited. Participants wore heart rate monitors and accelerometers during a typical rehabilitation day. Walking-related changes in heart rate and walking bout duration were determined. Patients did not meet the minimum cumulative requirements of walking intensity (>40% heart rate reserve) and duration (>10 minutes continuously) necessary for cardiorespiratory benefit. Only one patient exceeded 80% heart rate reserve. The absence of significant increases in heart rate associated with walking reveals that patients chose to walk at speeds well below a level that has meaningful cardiorespiratory health benefits. Additionally, cardiorespiratory workload is unlikely to limit participation in walking. Measurement of heart rate and walking during in-patient rehabilitation may be a useful approach to encourage patients to increase the overall physical activity and to help facilitate recovery.
Vasků, A; Soucek, M; Goldbergová, M; Vácha, J
2003-01-01
The aim of the study was to assess the association between promoter polymorphism [A(-596)G] in interleukin-6 gene and office systolic and diastolic blood pressures, and the heart rate (HR) in apparently healthy Czech subjects. Furthermore, we evaluated the possible influence of gender, BMI and smoking on these supposed associations. An age-matched (40-50 years) and gender-matched (F/M=81/89) sample of apparently healthy Czech subjects (n=170, F/M=81/89) without hypertension, other cardiovascular diseases or diabetes was examined. The A(-596)G Il-6 gene polymorphism was detected by the PCR method. No differences in genotype distribution and/or allelic frequency was found between groups with lower systolic blood pressure (Ł 122 mm Hg) and higher systolic blood pressure (> 122 mm Hg). Similarly, no differences in the IL-6 polymorphism were found between lower (Ł 86 mm Hg) and higher (> 86 mm Hg) diastolic blood pressure groups. However, we proved a significant increase of genotypes AG+GG as well as the allele (-596)G in higher (>78 beats/min) heart rate group. The genotypes AG+GG represent significantly higher relative risk for higher HR frequency, especially in women. Among lean persons with a low heart rate frequency, fewer AG+GG genotypes were determined than among any other subjects. The genotypes AG+GG are more frequent in non-smoking persons with higher HR compared to non-smoking subjects with lower HR, especially in women. Gender, BMI and smoking substantially modify the distribution of A(-596)G Il-6 gene polymorphism in apparently healthy persons with lower or higher heart rate.
Lenoir, Augustin; Trachsel, Dagmar S; Younes, Mohamed; Barrey, Eric; Robert, Céline
2017-01-01
Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland-Altman analysis and the Lin's coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, root mean square of successive differences, SD1, SD2, low frequency, high frequency), the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device.
Ferreira, João Fernando Monteiro; César, Luiz Antonio Machado; Gruppi, César J; Giorgi, Dante M A; Hueb, Whady A; Mansur, Antonio P; Ramires, José A F
2007-11-01
Few data are available on the behavior of myocardial ischemia during daily activities in patients with coronary artery disease receiving antianginal drug therapy. To study the mechanism generating myocardial ischemia by evaluating blood pressure and heart rate changes in patients with stable atherosclerotic disease receiving drug therapy and with evidence of myocardial ischemia. Fifty non-hospitalized patients (40 males) underwent 24-hour electrocardiographic monitoring synchronized with blood pressured monitoring. Thirty five episodes of myocardial ischemia were detected in 17 patients, with a total duration of 146.3 minutes; angina was reported in five cases. Twenty nine episodes (100.3 minutes) occurred during wakefulness, with 11 episodes (35.3 + 3.7 min) in the period from 11 a.m. to 3 p.m. Blood pressure and heart rate evaluation in the three ten-minute intervals following the ischemic episodes showed a statistically significant difference (p< 0.05), unlike that shown for the three intervals preceding the episodes. However, during the ischemic episode, a higher than 10-mmHg elevation in blood pressure and 5 beats per minute in heart rate were observed when compared with the time interval between 20 and 10 minutes before the episode. The mean heart rate at the onset of ischemia during the exercise test performed before the study was 118.2 + 14.0, and 81.1 + 20.8 beats per minute on the 24-hour electrocardiogram (p < 0.001). The incidence of silent myocardial ischemia is high in stable coronary artery disease and is related to alterations in blood pressure and heart rate, with different thresholds for ischemia for the same patient.
Studies in Fetal Behavior: Revisited, Renewed, and Reimagined
DiPietro, Janet A.; Costigan, Kathleen A.; Voegtline, Kristin M.
2016-01-01
Among the earliest volumes of this Monograph series was a report by Lester Sontag and colleagues, of the esteemed Fels Institute, on the heart rate of the human fetus as an expression of the developing nervous system. Here, some 75 years later, we commemorate this work and provide historical and contemporary context on knowledge regarding fetal development, as well as results from our own research. These are based on synchronized monitoring of maternal and fetal parameters assessed between 24 and 36 weeks gestation on 740 maternal-fetal pairs compiled from eight separate longitudinal studies, which commenced in the early 1990s. Data include maternal heart rate, respiratory sinus arrhythmia, and electrodermal activity and fetal heart rate, motor activity, and their integration. Hierarchical linear modeling of developmental trajectories reveals that the fetus develops in predictable ways consistent with advancing parasympathetic regulation. Findings also include: within-fetus stability (i.e., preservation of rank ordering over time) for heart rate, motor, and coupling measures; a transitional period of decelerating development near 30 weeks gestation; sex differences in fetal heart rate measures but not in most fetal motor activity measures; modest correspondence in fetal neurodevelopment among siblings as compared to unrelated fetuses; and deviations from normative fetal development in fetuses affected by intrauterine growth restriction and other conditions. Maternal parameters also change during this period of gestation and there is evidence that fetal sex and individual variation in fetal neurobehavior influence maternal physiological processes and the local intrauterine context. Results are discussed within the framework of neuromaturation, the emergence of individual differences, and the bidirectional nature of the maternal-fetal relationship. We pose a number of open questions for future research. Although the human fetus remains just out of reach, new technologies portend an era of accelerated discovery of the earliest period of development. PMID:26303396
Temporal resolution improvement using PICCS in MDCT cardiac imaging
Chen, Guang-Hong; Tang, Jie; Hsieh, Jiang
2009-01-01
The current paradigm for temporal resolution improvement is to add more source-detector units and∕or increase the gantry rotation speed. The purpose of this article is to present an innovative alternative method to potentially improve temporal resolution by approximately a factor of 2 for all MDCT scanners without requiring hardware modification. The central enabling technology is a most recently developed image reconstruction method: Prior image constrained compressed sensing (PICCS). Using the method, cardiac CT images can be accurately reconstructed using the projection data acquired in an angular range of about 120°, which is roughly 50% of the standard short-scan angular range (∼240° for an MDCT scanner). As a result, the temporal resolution of MDCT cardiac imaging can be universally improved by approximately a factor of 2. In order to validate the proposed method, two in vivo animal experiments were conducted using a state-of-the-art 64-slice CT scanner (GE Healthcare, Waukesha, WI) at different gantry rotation times and different heart rates. One animal was scanned at heart rate of 83 beats per minute (bpm) using 400 ms gantry rotation time and the second animal was scanned at 94 bpm using 350 ms gantry rotation time, respectively. Cardiac coronary CT imaging can be successfully performed at high heart rates using a single-source MDCT scanner and projection data from a single heart beat with gantry rotation times of 400 and 350 ms. Using the proposed PICCS method, the temporal resolution of cardiac CT imaging can be effectively improved by approximately a factor of 2 without modifying any scanner hardware. This potentially provides a new method for single-source MDCT scanners to achieve reliable coronary CT imaging for patients at higher heart rates than the current heart rate limit of 70 bpm without using the well-known multisegment FBP reconstruction algorithm. This method also enables dual-source MDCT scanner to achieve higher temporal resolution without further hardware modifications. PMID:19610302
Temporal resolution improvement using PICCS in MDCT cardiac imaging.
Chen, Guang-Hong; Tang, Jie; Hsieh, Jiang
2009-06-01
The current paradigm for temporal resolution improvement is to add more source-detector units and/or increase the gantry rotation speed. The purpose of this article is to present an innovative alternative method to potentially improve temporal resolution by approximately a factor of 2 for all MDCT scanners without requiring hardware modification. The central enabling technology is a most recently developed image reconstruction method: Prior image constrained compressed sensing (PICCS). Using the method, cardiac CT images can be accurately reconstructed using the projection data acquired in an angular range of about 120 degrees, which is roughly 50% of the standard short-scan angular range (approximately 240 degrees for an MDCT scanner). As a result, the temporal resolution of MDCT cardiac imaging can be universally improved by approximately a factor of 2. In order to validate the proposed method, two in vivo animal experiments were conducted using a state-of-the-art 64-slice CT scanner (GE Healthcare, Waukesha, WI) at different gantry rotation times and different heart rates. One animal was scanned at heart rate of 83 beats per minute (bpm) using 400 ms gantry rotation time and the second animal was scanned at 94 bpm using 350 ms gantry rotation time, respectively. Cardiac coronary CT imaging can be successfully performed at high heart rates using a single-source MDCT scanner and projection data from a single heart beat with gantry rotation times of 400 and 350 ms. Using the proposed PICCS method, the temporal resolution of cardiac CT imaging can be effectively improved by approximately a factor of 2 without modifying any scanner hardware. This potentially provides a new method for single-source MDCT scanners to achieve reliable coronary CT imaging for patients at higher heart rates than the current heart rate limit of 70 bpm without using the well-known multisegment FBP reconstruction algorithm. This method also enables dual-source MDCT scanner to achieve higher temporal resolution without further hardware modifications.
... The baby may also have a: Drop in heart rate. This heart rate drop is called bradycardia or, sometimes, a "brady." ... hospital. The monitors keep track of their breathing, heart rate, and oxygen levels. Apnea, drop in heart rate, ...
Feng, Qun; Li, Xiao-yu; Luan, Yong-fu; Sun, Sai-nan; Sun, Rong
2015-03-01
To study the effect of single administration of aqueous extracts from aconite on "dose-toxicity" relationship and "time-toxicity" relationship of mice hearts, through changes in electrocardiogram (ECG) and serum biochemical indexes. Mice were grouped according to different drug doses and time points, and orally administered with water extracts from aconite for once to observe the changes of mice ECG before and after the administration, calculate visceral indexes heart, liver and kidney, and detect levels of CK, LDH, BNP and CTn-I in serum. According to the "time-toxicity" relationship study, at 5 min after oral administration with aqueous extracts from aconite in mice, the heart rate of mice began rising, reached peak at 60 min and then slowly reduced; QRS, R amplitude, T duration and amplitude and QT interval declined at 5 min, reduced to the bottom at 60 min and then gradually elevated. The levels of CK, LDH, BNP and CTn-I in serum elevated at 5 min and reached the peak at 60 min, with no significant change in ratios of organs to body at different time points. On the basis of the "dose-toxicity" relationship, with the increase in single dose of aqueous extracts from aconite, the heart rate of mice. QRS, T duration and amplitude and QT interval declined gradually, and levels of CK, LDH, BNP and CTn-I in serum slowly elevated, with a certain dose dependence and no significant change in ratios of organs to body in mice. Single oral administration of different doses of aqueous extracts from aconite could cause different degrees of heart injury at different time points, with a certain dose dependence. Its peak time of toxicity is at 60 min after the administration of aqueous extracts from aconite.
Seebacher, F; Franklin, C E
2001-12-01
During thermoregulation in the bearded dragon Pogona barbata, heart rate when heating is significantly faster than when cooling at any given body temperature (heart rate hysteresis), resulting in faster rates of heating than cooling. However, the mechanisms that control heart rate during heating and cooling are unknown. The aim of this study was to test the hypothesis that changes in cholinergic and adrenergic tone on the heart are responsible for the heart rate hysteresis during heating and cooling in P. barbata. Heating and cooling trials were conducted before and after the administration of atropine, a muscarinic antagonist, and sotalol, a beta-adrenergic antagonist. Cholinergic and beta-adrenergic blockade did not abolish the heart rate hysteresis, as the heart rate during heating was significantly faster than during cooling in all cases. Adrenergic tone was extremely high (92.3 %) at the commencement of heating, and decreased to 30.7 % at the end of the cooling period. Moreover, in four lizards there was an instantaneous drop in heart rate (up to 15 beats min(-1)) as the heat source was switched off, and this drop in heart rate coincided with either a drop in beta-adrenergic tone or an increase in cholinergic tone. Rates of heating were significantly faster during the cholinergic blockade, and least with a combined cholinergic and beta-adrenergic blockade. The results showed that cholinergic and beta-adrenergic systems are not the only control mechanisms acting on the heart during heating and cooling, but they do have a significant effect on heart rate and on rates of heating and cooling.
Maternal cardiac and obstetric performance in consecutive pregnancies in women with heart disease.
Gelson, E; Curry, R; Gatzoulis, M A; Swan, L; Lupton, M; Steer, P J; Johnson, M R
2015-10-01
Second pregnancies are usually less complicated than first pregnancies, and have a better outcome in terms of fetal growth. We studied a group of women with heart disease to assess whether their second pregnancy was less complicated and resulted in a larger baby. Retrospective case control study. Tertiary referral academic obstetric unit. First and second pregnancies in 77 women with congenital and acquired heart disease and in 154 control women were identified. Data were collected from medical and obstetric records. Cardiac complications, obstetric complications, intra-partum events, birthweight and perinatal complications. The rate of obstetric complication was greater in first pregnancies in both the heart disease and the control groups (38% versus 26%, cf. 20% versus 17%). In the heart disease group, the rate of cardiac complications was similar in first and second pregnancies (9% versus 6%). Overall, significantly more perinatal complications were seen in the heart disease group, with no significant difference between first and second pregnancies (36% versus 27%, cf. 14% versus 12%). Median birthweight was significantly higher in second pregnancies in the control group (3308 versus 3519 g P < 0.001), but not significantly different between pregnancies in the heart disease group (3014 versus 3133 g, P = 0.19). This case control study demonstrates that women with mild to moderate heart disease have similar pregnancy outcomes in consecutive pregnancies. However, while the median birthweight was higher in the control second pregnancies, it was not increased in the women with heart disease. A study of women with heart disease to assess whether their second pregnancy was less complicated. © 2015 Royal College of Obstetricians and Gynaecologists.
den Hoed, Marcel; Eijgelsheim, Mark; Esko, Tõnu; Brundel, Bianca J J M; Peal, David S; Evans, David M; Nolte, Ilja M; Segrè, Ayellet V; Holm, Hilma; Handsaker, Robert E; Westra, Harm-Jan; Johnson, Toby; Isaacs, Aaron; Yang, Jian; Lundby, Alicia; Zhao, Jing Hua; Kim, Young Jin; Go, Min Jin; Almgren, Peter; Bochud, Murielle; Boucher, Gabrielle; Cornelis, Marilyn C; Gudbjartsson, Daniel; Hadley, David; van der Harst, Pim; Hayward, Caroline; den Heijer, Martin; Igl, Wilmar; Jackson, Anne U; Kutalik, Zoltán; Luan, Jian'an; Kemp, John P; Kristiansson, Kati; Ladenvall, Claes; Lorentzon, Mattias; Montasser, May E; Njajou, Omer T; O'Reilly, Paul F; Padmanabhan, Sandosh; St Pourcain, Beate; Rankinen, Tuomo; Salo, Perttu; Tanaka, Toshiko; Timpson, Nicholas J; Vitart, Veronique; Waite, Lindsay; Wheeler, William; Zhang, Weihua; Draisma, Harmen H M; Feitosa, Mary F; Kerr, Kathleen F; Lind, Penelope A; Mihailov, Evelin; Onland-Moret, N Charlotte; Song, Ci; Weedon, Michael N; Xie, Weijia; Yengo, Loic; Absher, Devin; Albert, Christine M; Alonso, Alvaro; Arking, Dan E; de Bakker, Paul I W; Balkau, Beverley; Barlassina, Cristina; Benaglio, Paola; Bis, Joshua C; Bouatia-Naji, Nabila; Brage, Søren; Chanock, Stephen J; Chines, Peter S; Chung, Mina; Darbar, Dawood; Dina, Christian; Dörr, Marcus; Elliott, Paul; Felix, Stephan B; Fischer, Krista; Fuchsberger, Christian; de Geus, Eco J C; Goyette, Philippe; Gudnason, Vilmundur; Harris, Tamara B; Hartikainen, Anna-Liisa; Havulinna, Aki S; Heckbert, Susan R; Hicks, Andrew A; Hofman, Albert; Holewijn, Suzanne; Hoogstra-Berends, Femke; Hottenga, Jouke-Jan; Jensen, Majken K; Johansson, Asa; Junttila, Juhani; Kääb, Stefan; Kanon, Bart; Ketkar, Shamika; Khaw, Kay-Tee; Knowles, Joshua W; Kooner, Angrad S; Kors, Jan A; Kumari, Meena; Milani, Lili; Laiho, Päivi; Lakatta, Edward G; Langenberg, Claudia; Leusink, Maarten; Liu, Yongmei; Luben, Robert N; Lunetta, Kathryn L; Lynch, Stacey N; Markus, Marcello R P; Marques-Vidal, Pedro; Mateo Leach, Irene; McArdle, Wendy L; McCarroll, Steven A; Medland, Sarah E; Miller, Kathryn A; Montgomery, Grant W; Morrison, Alanna C; Müller-Nurasyid, Martina; Navarro, Pau; Nelis, Mari; O'Connell, Jeffrey R; O'Donnell, Christopher J; Ong, Ken K; Newman, Anne B; Peters, Annette; Polasek, Ozren; Pouta, Anneli; Pramstaller, Peter P; Psaty, Bruce M; Rao, Dabeeru C; Ring, Susan M; Rossin, Elizabeth J; Rudan, Diana; Sanna, Serena; Scott, Robert A; Sehmi, Jaban S; Sharp, Stephen; Shin, Jordan T; Singleton, Andrew B; Smith, Albert V; Soranzo, Nicole; Spector, Tim D; Stewart, Chip; Stringham, Heather M; Tarasov, Kirill V; Uitterlinden, André G; Vandenput, Liesbeth; Hwang, Shih-Jen; Whitfield, John B; Wijmenga, Cisca; Wild, Sarah H; Willemsen, Gonneke; Wilson, James F; Witteman, Jacqueline C M; Wong, Andrew; Wong, Quenna; Jamshidi, Yalda; Zitting, Paavo; Boer, Jolanda M A; Boomsma, Dorret I; Borecki, Ingrid B; van Duijn, Cornelia M; Ekelund, Ulf; Forouhi, Nita G; Froguel, Philippe; Hingorani, Aroon; Ingelsson, Erik; Kivimaki, Mika; Kronmal, Richard A; Kuh, Diana; Lind, Lars; Martin, Nicholas G; Oostra, Ben A; Pedersen, Nancy L; Quertermous, Thomas; Rotter, Jerome I; van der Schouw, Yvonne T; Verschuren, W M Monique; Walker, Mark; Albanes, Demetrius; Arnar, David O; Assimes, Themistocles L; Bandinelli, Stefania; Boehnke, Michael; de Boer, Rudolf A; Bouchard, Claude; Caulfield, W L Mark; Chambers, John C; Curhan, Gary; Cusi, Daniele; Eriksson, Johan; Ferrucci, Luigi; van Gilst, Wiek H; Glorioso, Nicola; de Graaf, Jacqueline; Groop, Leif; Gyllensten, Ulf; Hsueh, Wen-Chi; Hu, Frank B; Huikuri, Heikki V; Hunter, David J; Iribarren, Carlos; Isomaa, Bo; Jarvelin, Marjo-Riitta; Jula, Antti; Kähönen, Mika; Kiemeney, Lambertus A; van der Klauw, Melanie M; Kooner, Jaspal S; Kraft, Peter; Iacoviello, Licia; Lehtimäki, Terho; Lokki, Marja-Liisa L; Mitchell, Braxton D; Navis, Gerjan; Nieminen, Markku S; Ohlsson, Claes; Poulter, Neil R; Qi, Lu; Raitakari, Olli T; Rimm, Eric B; Rioux, John D; Rizzi, Federica; Rudan, Igor; Salomaa, Veikko; Sever, Peter S; Shields, Denis C; Shuldiner, Alan R; Sinisalo, Juha; Stanton, Alice V; Stolk, Ronald P; Strachan, David P; Tardif, Jean-Claude; Thorsteinsdottir, Unnur; Tuomilehto, Jaako; van Veldhuisen, Dirk J; Virtamo, Jarmo; Viikari, Jorma; Vollenweider, Peter; Waeber, Gérard; Widen, Elisabeth; Cho, Yoon Shin; Olsen, Jesper V; Visscher, Peter M; Willer, Cristen; Franke, Lude; Erdmann, Jeanette; Thompson, John R; Pfeufer, Arne; Sotoodehnia, Nona; Newton-Cheh, Christopher; Ellinor, Patrick T; Stricker, Bruno H Ch; Metspalu, Andres; Perola, Markus; Beckmann, Jacques S; Smith, George Davey; Stefansson, Kari; Wareham, Nicholas J; Munroe, Patricia B; Sibon, Ody C M; Milan, David J; Snieder, Harold; Samani, Nilesh J; Loos, Ruth J F
2013-06-01
Elevated resting heart rate is associated with greater risk of cardiovascular disease and mortality. In a 2-stage meta-analysis of genome-wide association studies in up to 181,171 individuals, we identified 14 new loci associated with heart rate and confirmed associations with all 7 previously established loci. Experimental downregulation of gene expression in Drosophila melanogaster and Danio rerio identified 20 genes at 11 loci that are relevant for heart rate regulation and highlight a role for genes involved in signal transmission, embryonic cardiac development and the pathophysiology of dilated cardiomyopathy, congenital heart failure and/or sudden cardiac death. In addition, genetic susceptibility to increased heart rate is associated with altered cardiac conduction and reduced risk of sick sinus syndrome, and both heart rate-increasing and heart rate-decreasing variants associate with risk of atrial fibrillation. Our findings provide fresh insights into the mechanisms regulating heart rate and identify new therapeutic targets.
Comparison of 2 heterotopic heart transplant techniques in rats: cervical and abdominal heart.
Ma, Yi; Wang, Guodong
2011-04-01
Heterotopic heart transplant in rats has been accepted as the most commonly used animal model to investigate the mechanisms of transplant immunology. Many ingenious approaches to this model have been reported. We sought to improve this model and compare survival rates and histologic features of acute rejection in cervical and abdominal heart transplants. Rats were divided into cervical and abdominal groups. Microsurgical techniques were introduced for vascular anastomoses. In the abdominal heart transplant group, the donor's thoracic aorta was anastomosed end-to-side to the recipient's infrarenal abdominal aorta, and the donor's pulmonary artery was anastomosed to the recipient's inferior vena cava. In the cervical heart transplant group, the donor's thoracic aorta was anastomosed to the recipient's common carotid artery, and the donor's pulmonary artery was anastomosed to the recipient's external jugular vein. Survival time of the 2 models was followed and pathology was examined. Histologic features of allogeneic rejection also were compared in the cervical and abdominal heart transplant groups. The mean time to recover the donor's hearts was 7.4 ± 2.2 minutes in the cervical group and 7.2 ± 1.8 minutes in the abdominal group. In the cervical and abdominal heart transplant models, the mean recipient's operative time was 23.2 ± 2.6 minutes and 21.6 ± 2.8 minutes. Graft survival was 98% and 100% in the cervical and abdominal heart transplant groups. There was no significant difference in graft survival between the 2 methods. Heart allografts rejected at 5.7 and 6.2 days in the cervical and abdominal transplant groups. There was no difference in the histologic features of acute allogenic rejection in cervical and abdominal heart transplant. Both cervical and abdominal heart transplants can achieve a high rate of success. The histologic features of acute allogeneic rejection in the models are comparable.
Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity.
Jarchi, Delaram; Casson, Alexander J
2017-09-01
Recently numerous methods have been proposed for estimating average heart rate using photoplethysmography (PPG) during physical activity, overcoming the significant interference that motion causes in PPG traces. We propose a new algorithm framework for extracting instantaneous heart rate from wearable PPG and Electrocardiogram (ECG) signals to provide an estimate of heart rate variability during exercise. For ECG signals, we propose a new spectral masking approach which modifies a particle filter tracking algorithm, and for PPG signals constrains the instantaneous frequency obtained from the Hilbert transform to a region of interest around a candidate heart rate measure. Performance is verified using accelerometry and wearable ECG and PPG data from subjects while biking and running on a treadmill. Instantaneous heart rate provides more information than average heart rate alone. The instantaneous heart rate can be extracted during motion to an accuracy of 1.75 beats per min (bpm) from PPG signals and 0.27 bpm from ECG signals. Estimates of instantaneous heart rate can now be generated from PPG signals during motion. These estimates can provide more information on the human body during exercise. Instantaneous heart rate provides a direct measure of vagal nerve and sympathetic nervous system activity and is of substantial use in a number of analyzes and applications. Previously it has not been possible to estimate instantaneous heart rate from wrist wearable PPG signals.
Gay, Estelle; Bornallet, Géraldine; Gaucherand, Pascal; Doret, Muriel
2015-11-01
To assess if the fetal electrocardiogram especially ST segment is modified by congenital heart diseases: modifications in frequencies of the different ST events and modifications in signal quality. A retrospective case-control study, comparing frequencies of the different ST events and the quality of the signal between fetuses with congenital heart diseases and fetuses without congenital heart disease. From 2000 to 2011, fifty-eight fetuses with congenital heart disease had their heart rate recording using a STAN device during labor. Control group was fetuses who were born just before a case and had a STAN as a second line for intrapartum surveillance. Cases and controls were matched on parity, gestational age at birth, presence of growth restriction and umbilical artery pH. Frequencies of the different ST event and quality of the signal were first analyzed for the global labor recording, and then separately for the first and the second phase of labor. No statistically significant difference in ST event frequencies between fetuses with congenital heart disease and the control group was found. Regarding the quality of the signal, 11.49% (±18.82) of recording time is a signal loss for fetus with congenital heart disease whereas only 5.18% (±10.67) for the control group (p=0.028). This is the first study investigating for intrapartum electrocardiogram modification in fetus with congenital heart disease. Congenital heart diseases do not modify frequencies of ST events. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L
2014-01-01
Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.
Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L.
2014-01-01
Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain. PMID:25324790
Barak, Otto F.; Ovcin, Zoran B.; Jakovljevic, Djordje G.; Lozanov-Crvenkovic, Zagorka; Brodie, David A.; Grujic, Nikola G.
2011-01-01
The effects of different recovery protocols on heart rate recovery (HRR) trend through fitted heart rate (HR) decay curves were assessed. Twenty one trained male athletes and 19 sedentary male students performed a submaximal cycle exercise test on four occasions followed by 5 min: 1) inactive recovery in the upright seated position, 2) active (cycling) recovery in the upright seated position, 3) supine position, and 4) supine position with elevated legs. The HRR was assessed as the difference between the peak exercise HR and the HR recorded following 60 seconds of recovery (HRR60). Additionally the time constant decay was obtained by fitting the 5 minute post-exercise HRR into a first-order exponential curve. Within- subject differences of HRR60 for all recovery protocols in both groups were significant (p < 0. 001) except for the two supine positions (p > 0.05). Values of HRR60 were larger in the group of athletes for all conditions (p < 0.001). The time constant of HR decay showed within-subject differences for all recovery conditions in both groups (p < 0.01) except for the two supine positions (p > 0.05). Between group difference was found for active recovery in the seated position and the supine position with elevated legs (p < 0.05). We conclude that the supine position with or without elevated legs accelerated HRR compared with the two seated positions. Active recovery in the seated upright position was associated with slower HRR compared with inactive recovery in the same position. The HRR in athletes was accelerated in the supine position with elevated legs and with active recovery in the seated position compared with non-athletes. Key points In order to return to a pre-exercise value following exercise, heart rate (HR) is mediated by changes in the autonomic nervous system but the underlying mechanisms governing these changes are not well understood. Even though HRR is slower with active recovery, lactate elimination after high intensity exercise might be more important for athletes than the de-cline of heart rate. Lying supine during recovery after exercise may be an effective means of transiently restoring HR and vagal modulation and a safe position for prevention of syncope. PMID:24149885
Guglielmo, A; Reader, A; Nist, R; Beck, M; Weaver, J
1999-03-01
The purpose of this study was to determine the anesthetic efficacy and heart rate effects of a supplemental intraosseous injection of 2% mepivacaine with 1:20,000 levonordefrin. Through use of a repeated-measures design, 40 subjects randomly received 3 combinations of injections at 3 separate appointments. The combinations were as follows: inferior alveolar nerve (IAN) block (with 3% mepivacaine) + intraosseous injection of 1.8 mL of 2% mepivacaine with 1:20,000 levonordefrin; IAN block + intraosseous injection of 1.8 mL of 2% lidocaine with 1:100,000 epinephrine (positive control); IAN block + mock intraosseous injection (negative control). Each first molar, second molar, and second premolar was blindly tested with a pulp tester at 2-minute cycles for 60 minutes after injection. Anesthesia was considered successful when 2 consecutive readings of 80 were obtained. Heart rate (pulse rate) was measured with a pulse oximeter. One hundred percent of the subjects had lip numbness with the IAN block + intraosseous mock technique and IAN block + intraosseous techniques. The anesthetic success rates for IAN block + mock intraosseous injection, IAN block + intraosseous lidocaine, and IAN block + intraosseous mepivacaine, respectively, were as follows: 80%, 100%, and 100% for the first molar; 90%, 100%, and 100% for the second molar; 77%, 97%, and 97% for the second premolar. For the first molar and second premolar, the differences were significant (P< .05) when the intraosseous mepivacaine and lidocaine techniques were compared with the IAN block + mock intraosseous injection. There were no significant differences between the intraosseous mepivacaine and lidocaine techniques. Eighty percent of the subjects had a mean increase in heart rate of 23-24 beats per minute with the intraosseous injection of the mepivacaine and lidocaine solutions; there were no significant differences between results with the 2 solutions. We concluded that intraosseous injection of 1.8 mL of 2% lidocaine with 1:100,000 epinephrine or 2% mepivacaine with 1:20,000 levonordefrin, used to supplement an IAN block, significantly increased anesthetic success in first molars and second premolars. The 2 solutions were equivalent with regard to intraosseous anesthetic success rate, failure rate, and heart rate increase after IAN block.
NASA Astrophysics Data System (ADS)
Baum, K.; Essfeld, D.; Stegemann, J.
To investigate the effect of μg-induced peripheral extracellular fluid reductions on heart rate and blood pressure during isometric exercise, six healthy male subjects performed three calf ergometer test with different extracellular volumes of working muscles. In all tests, body positions during exercise were identical (supine with the knee joint flexed to 900). After a pre-exercise period of 25 min, during which calf volumes were manipulated, subjects had to counteract an external force of 180 N for 5 min. During the pre-exercise period three different protocols were applied. Test A: Subjects rested in the exercise position; test B: Body position was the same as in A but calf volume was increased by venous congestion (cuffs inflated to 80 mm Hg); test C: Calf volumes were decreased by a negative hydrostatic pressure (calves about 40 cm above heart level with the subjects supine). To clamp the changed calf volumes in tests B and C, cuffs were inflated to 300 mm Hg 5 min before the onset of exercise. This occlusion was maintained until termination of exercise. Compared to tests A and B, the reduced volume of test C led to significant increases in heart rate and blood pressure during exercise. Oxygen uptake did not exceed resting levels in B and C until cuffs were deflated, indicating that exclusively calf muscles contributed to the neurogenic peripheral drive. It is concluded that changes in extracellular muscle volume have to be taken into account when comparing heart rate and blood pressure during lg- and μg- exercise.
The Study of Biobehavioral Rhythms in a Psychology Laboratory Course.
ERIC Educational Resources Information Center
Rowland, David L.; Wesselhoft, Theresa
1998-01-01
Reports on a laboratory experiment where students measured their heart rate, blood pressure, mood, alertness, and cognitive performance. Measures showed significant circadian heart rhythm variations. They were strongly correlated and peaked at different times. Discusses the implications of this and students' reactions to the experiment. (MJP)
Guzik, Przemyslaw; Piekos, Caroline; Pierog, Olivia; Fenech, Naiman; Krauze, Tomasz; Piskorski, Jaroslaw; Wykretowicz, Andrzej
2018-05-01
We compared classic ECG-derived versus a mobile approach to heart rate variability (HRV) measurement. 29 young adult healthy volunteers underwent a simultaneous recording of heart rate using an ECG and a chest heart rate monitor at supine rest, during mental stress and active standing. Mean RR interval, Standard Deviation of Normal-to-Normal (SDNN) of RR intervals, and Root Mean Square of the Successive Differences (RMSSD) between RR intervals were computed in 168 pairs of 5-minute epochs by in-house software on a PC (only sinus beats) and by mobile application "ELITEHRV" on a smartphone (no beat type identification). ECG analysis showed that 33.9% of the recordings contained at least one non-sinus beat or artefact, the mobile app did not report this. The mean RR intervals were significantly longer (p = 0.0378), while SDNN (p = 0.0001) and RMSSD (p = 0.0199) were smaller for the mobile approach. Measures of identical HRV parameters by ECG-based and mobile approaches are not equivalent. Copyright © 2018 Elsevier B.V. All rights reserved.
Wood, Mark; Reader, Al; Nusstein, John; Beck, Mike; Padgett, David; Weaver, Joel
2005-06-01
The purpose of this prospective, randomized study was to compare the venous blood levels of lidocaine and heart rate changes after intraosseous and infiltration injections of 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. Using a crossover design, 20 subjects randomly received an intraosseous and infiltration injection at two separate appointments. The heart rate was measured using a pulse oximeter. Venous blood samples were collected before the injections and at 2, 5, 10, 15, 20, 25, 30, 45, and 60 min after the injections. The blinded plasma samples were analyzed for lidocaine concentrations using high-performance liquid chromatography (HPLC). The intraosseous injection resulted in a statistically significant increase in heart rate, when compared to the infiltration injection, during solution deposition and for 2 min after the injection. The plasma levels of lidocaine were not statistically different for maxillary anterior intraosseous and infiltration injections when using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine.
Patterson, Jae T; Hart, Amanda; Hansen, Steve; Carter, Michael J; Ditor, David
2016-04-01
Heart rate variability (i.e., low frequency:high frequency ratio) was measured to differentiate invested cognitive effort during the acquisition and retention of a novel task. Participants (12 male, M = 25.1 year, SD = 3.6; 12 female, M = 22.8 year, SD = 1.1) were required to produce Braille equivalents of English letter primes on a standardized keyboard in proactive or retroactive conditions (groups, each n = 12). The correct Braille response was either provided before (i.e., proactively) or after (i.e., retroactively) the participant's response. During acquisition, participants in the proactive group demonstrated shorter study time, greater recall success, and reported lower cognitive investment. Participants in the proactive and retroactive groups did not statistically differ in heart rate variability. For retention, the retroactive group showed greater recall success, lower perceived cognitive effort investment, and lower heart rate variability. The results highlight the usefulness of heart rate variability in discriminating the cognitive effort invested for a recently acquired skill. © The Author(s) 2016.
Association of auricular pressing and heart rate variability in pre-exam anxiety students.
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-03-25
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety.
Association of auricular pressing and heart rate variability in pre-exam anxiety students
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-01-01
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety. PMID:25206734
Heart Rate During Sleep: Implications for Monitoring Training Status
Waldeck, Miriam R.; Lambert, Michael I.
2003-01-01
Resting heart rate has sometimes been used as a marker of training status. It is reasonable to assume that the relationship between heart rate and training status should be more evident during sleep when extraneous factors that may influence heart rate are reduced. Therefore the aim of the study was to assess the repeatability of monitoring heart rate during sleep when training status remained unchanged, to determine if this measurement had sufficient precision to be used as a marker of training status. The heart rate of ten female subjects was monitored for 24 hours on three occasions over three weeks whilst training status remained unchanged. Average, minimum and maximum heart rate during sleep was calculated. The average heart rate of the group during sleep was similar on each of the three tests (65 ± 9, 63 ± 6 and 67 ± 7 beats·min-1 respectively). The range in minimum heart rate variation during sleep for all subjects over the three testing sessions was from 0 to 10 beats·min-1 (mean = 5 ± 3 beats·min-1) and for maximum heart rate variation was 2 to 31 beats·min-1 (mean = 13 ± 9 beats·min-1). In summary it was found that on an individual basis the minimum heart rate during sleep varied by about 8 beats·min-1. This amount of intrinsic day-to-day variation needs to be considered when changes in heart rate that may occur with changes in training status are interpreted. PMID:24688273
Matusik, P S; Matusik, P T; Stein, P K
2018-07-01
Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.
Cnota, James F; Gupta, Resmi; Michelfelder, Erik C; Ittenbach, Richard F
2011-11-01
To describe congenital heart disease death rates in infants born between 34 and 40 weeks, estimate the relationship between gestational age and congenital heart disease infant death rates, and compare congenital heart disease death rates across 1- and 2-week intervals in gestational age. The 2000 to 2003 national linked birth/infant death cohort datasets were obtained. Congenital heart disease deaths were identified by using International Statistical Classification of Diseases, 10th Revision codes. Proportional death rates were calculated by using congenital heart disease deaths and all live births. The relationship between congenital heart disease death rates and gestational age was determined. Death rates were compared across intervals. A total of 14.9 million records were analyzed. Congenital heart disease deaths occurred in 4736 infants (0.04%) born between 34 and 40 weeks. There was a significant, negative linear relationship between congenital heart disease death rate and gestational age (R(2) = 0.97). Comparisons across 1-week intervals varied (P = .02-.23). All 2-week intervals were statistically significant (P < .01). Congenital heart disease death rates decrease as gestational age approaches 40 weeks. These results should be considered before elective delivery for the sole indication of prenatally diagnosed congenital heart disease. Copyright © 2011 Mosby, Inc. All rights reserved.
Chu, Jennifer; Bruyninckx, Frans; Neuhauser, Duncan V
2017-07-01
Favourable pain relief results on evoking autonomous twitches at myofascial trigger points with Electrical Twitch Obtaining Intramuscular Stimulation (ETOIMS). To document autonomic nervous system (ANS) dysfunction in Complex Regional Pain Syndrome (CRPS) from blood pressure (BP) and pulse/heart rate changes with ETOIMS. A patient with persistent pain regularly received serial ETOIMS sessions of 60, 90, 120 or ≥150 min over 24 months. Outcome measures include BP: systolic, diastolic, pulse pressure and pulse/heart rate, pre-session/immediate-post-session summed differences (SDPPP index), and pain reduction. His results were compared with that of two other patients and one normal control. Each individual represented the following maximal elicitable twitch forces (TWF) graded 1-5: maximum TWF2: control subject; maximum TWF3: CRPS patient with suspected ANS dysfunction; and maximum TWF4 and TWF5: two patients with respective slow-fatigue and fast-fatigue twitches who during ETOIMS had autonomous twitching at local and remote myotomes simultaneously from denervation supersensitivity. ETOIMS results between TWFs were compared using one-way analysis of variance test. The patients showed immediate significant pain reduction, BP and pulse/heart rate changes/reduction(s) except for diastolic BP in the TWF5 patient. TWF2 control subject had diastolic BP reduction with ETOIMS but not with rest. Linear regression showed TWF grade to be the most significant variable in pain reduction, more so than the number of treatments, session duration and treatment interval. TWF grade was the most important variable in significantly reducing outcome measures, especially pulse/heart rate. Unlike others, the TWF3 patient had distinctive reductions in SDPPP index. Measuring BP and pulse/heart rate is clinically practical for alerting ANS dysfunction maintained CRPS. SDPPP index (≥26) and pulse/heart rate (≥8) reductions with almost every ETOIMS treatment, plus inability to evoke autonomous twitches due to pain-induced muscle hypertonicity, are pathognomonic of this problem.
A less stressful alternative to oral gavage for pharmacological and toxicological studies in mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Mary K., E-mail: mwalker@salud.unm.edu; Boberg, Jason R.; Walsh, Mary T.
Oral gavage dosing can induce stress and potentially confound experimental measurements, particularly when blood pressure and heart rate are endpoints of interest. Thus, we developed a pill formulation that mice would voluntarily consume and tested the hypothesis that pill dosing would be significantly less stressful than oral gavage. C57Bl/6 male mice were singly housed and on four consecutive days were exposed to an individual walking into the room (week 1, control), a pill being placed into the cage (week 2), and a dose of water via oral gavage (week 3). Blood pressure and heart rate were recorded by radiotelemetry continuouslymore » for 5 h after treatment, and feces collected 6–10 h after treatment for analysis of corticosterone metabolites. Both pill and gavage dosing significantly increased mean arterial pressure (MAP) during the first hour, compared to control. However, the increase in MAP was significantly greater after gavage and remained elevated up to 5 h, while MAP returned to normal within 2 h after a pill. Neither pill nor gavage dosing significantly increased heart rate during the first hour, compared to control; however, pill dosing significantly reduced heart rate while gavage significantly increased heart rate 2–5 h post dosing. MAP and heart rate did not differ 24 h after dosing. Lastly, only gavage dosing significantly increased fecal corticosterone metabolites, indicating a systemic stress response via activation of the hypothalamic–pituitary–adrenal axis. These data demonstrated that this pill dosing method of mice is significantly less stressful than oral gavage. -- Highlights: ► Developed a novel oral dosing method using a pill that mice will readily consume. ► Assessed stress by blood pressure, heart rate, and fecal corticosterone metabolites. ► Demonstrated that pill dosing is significantly less stressful than oral gavage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
McAuliffe, J.J.; Perry, S.B.; Brooks, E.E.
1991-03-12
Here the authors define the kinetics of the creatine kinase (CK) reaction in an intact mammalian heart containing the full rnage of CK isoenzymes. Previously derived kinetic constants were refit for the reaction occurring at 37C. Steady-state metabolite concentrations from {sup 31}P NMR and standard biochemical techniques were determined. {sup 31}P magnetization transfer data were obtained to determine unidirectional creatine kinase fluxes in hearts with differing total creatine contents and differing mitochondrial CK activities during KCl arrest and isovolumic work for both the forward reaction (MgATP synthesis) and reverse reaction (phosphocreatine synthesis). The NMR kinetic data and substrate concentrations datamore » were used in conjunction with a kinetic model based on MM-CK in solution to determine the applicability of the solution-based kinetic models to the CK kinetics of the intact heart. The results indicated that no single set of rate equation constants could describe both the KCl-arrested and working hearts. Analysis of the results indicated that the CK reaction is rate limited in the direction of ATP synthesis, the size of the guanidino substrate pool drives the measured CK flux in the intact heart, and during isovolumic work, the CK reaction operates under saturating conditions; that is, the substrate concentrations are at least 2-fold greater than the K{sub m} or K{sub im} for each substrate. However, during KCl arrest the reaction does not operate under saturating conditions and the CK reaction velocity is strongly influenced by the guanidino substrate pool size.« less
Graham, Rebecca A; Scott, Brandon G; Weems, Carl F
2017-05-01
Adolescence is a potentially important time in the development of emotion regulation and parenting behaviors may play a role. We examined associations among parenting behaviors, parent resting heart rate variability, adolescent resting heart rate variability and parenting behaviors as moderators of the association between parent and adolescent resting heart rate variability. Ninety-seven youth (11-17 years; 49.5 % female; 34 % African American, 37.1 % Euro-American, 22.6 % other/mixed ethnic background, and 7.2 % Hispanic) and their parents (n = 81) completed a physiological assessment and questionnaires assessing parenting behaviors. Inconsistent discipline and corporal punishment were negatively associated with adolescent resting heart rate variability, while positive parenting and parental involvement were positively associated. Inconsistent discipline and parental involvement moderated the relationship between parent and adolescent resting heart rate variability. The findings provide evidence for a role of parenting behaviors in shaping the development of adolescent resting heart rate variability with inconsistent discipline and parental involvement potentially influencing the entrainment of resting heart rate variability in parents and their children.
Endothelin-1 signalling controls early embryonic heart rate in vitro and in vivo.
Karppinen, S; Rapila, R; Mäkikallio, K; Hänninen, S L; Rysä, J; Vuolteenaho, O; Tavi, P
2014-02-01
Spontaneous activity of embryonic cardiomyocytes originates from sarcoplasmic reticulum (SR) Ca(2+) release during early cardiogenesis. However, the regulation of heart rate during embryonic development is still not clear. The aim of this study was to determine how endothelin-1 (ET-1) affects the heart rate of embryonic mice, as well as the pathway through which it exerts its effects. The effects of ET-1 and ET-1 receptor inhibition on cardiac contraction were studied using confocal Ca(2+) imaging of isolated mouse embryonic ventricular cardiomyocytes and ultrasonographic examination of embryonic cardiac contractions in utero. In addition, the amount of ET-1 peptide and ET receptor a (ETa) and b (ETb) mRNA levels were measured during different stages of development of the cardiac muscle. High ET-1 concentration and expression of both ETa and ETb receptors was observed in early cardiac tissue. ET-1 was found to increase the frequency of spontaneous Ca(2+) oscillations in E10.5 embryonic cardiomyocytes in vitro. Non-specific inhibition of ET receptors with tezosentan caused arrhythmia and bradycardia in isolated embryonic cardiomyocytes and in whole embryonic hearts both in vitro (E10.5) and in utero (E12.5). ET-1-mediated stimulation of early heart rate was found to occur via ETb receptors and subsequent inositol trisphosphate receptor activation and increased SR Ca(2+) leak. Endothelin-1 is required to maintain a sufficient heart rate, as well as to prevent arrhythmia during early development of the mouse heart. This is achieved through ETb receptor, which stimulates Ca(2+) leak through IP3 receptors. © 2013 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.
Increased walking variability in elderly persons with congestive heart failure
NASA Technical Reports Server (NTRS)
Hausdorff, J. M.; Forman, D. E.; Ladin, Z.; Goldberger, A. L.; Rigney, D. R.; Wei, J. Y.
1994-01-01
OBJECTIVES: To determine the effects of congestive heart failure on a person's ability to walk at a steady pace while ambulating at a self-determined rate. SETTING: Beth Israel Hospital, Boston, a primary and tertiary teaching hospital, and a social activity center for elderly adults living in the community. PARTICIPANTS: Eleven elderly subjects (aged 70-93 years) with well compensated congestive heart failure (NY Heart Association class I or II), seven elderly subjects (aged 70-79 years) without congestive heart failure, and 10 healthy young adult subjects (aged 20-30 years). MEASUREMENTS: Subjects walked for 8 minutes on level ground at their own selected walking rate. Footswitches were used to measure the time between steps. Step rate (steps/minute) and step rate variability were calculated for the entire walking period, for 30 seconds during the first minute of the walk, for 30 seconds during the last minute of the walk, and for the 30-second period when each subject's step rate variability was minimal. Group means and 5% and 95% confidence intervals were computed. MAIN RESULTS: All measures of walking variability were significantly increased in the elderly subjects with congestive heart failure, intermediate in the elderly controls, and lowest in the young subjects. There was no overlap between the three groups using the minimal 30-second variability (elderly CHF vs elderly controls: P < 0.001, elderly controls vs young: P < 0.001), and no overlap between elderly subjects with and without congestive heart failure when using the overall variability. For all four measures, there was no overlap in any of the confidence intervals, and all group means were significantly different (P < 0.05).
Milani-Nejad, Nima; Canan, Benjamin D; Elnakish, Mohammad T; Davis, Jonathan P; Chung, Jae-Hoon; Fedorov, Vadim V; Binkley, Philip F; Higgins, Robert S D; Kilic, Ahmet; Mohler, Peter J; Janssen, Paul M L
2015-12-15
Cross-bridge cycling rate is an important determinant of cardiac output, and its alteration can potentially contribute to reduced output in heart failure patients. Additionally, animal studies suggest that this rate can be regulated by muscle length. The purpose of this study was to investigate cross-bridge cycling rate and its regulation by muscle length under near-physiological conditions in intact right ventricular muscles of nonfailing and failing human hearts. We acquired freshly explanted nonfailing (n = 9) and failing (n = 10) human hearts. All experiments were performed on intact right ventricular cardiac trabeculae (n = 40) at physiological temperature and near the normal heart rate range. The failing myocardium showed the typical heart failure phenotype: a negative force-frequency relationship and β-adrenergic desensitization (P < 0.05), indicating the expected pathological myocardium in the right ventricles. We found that there exists a length-dependent regulation of cross-bridge cycling kinetics in human myocardium. Decreasing muscle length accelerated the rate of cross-bridge reattachment (ktr) in both nonfailing and failing myocardium (P < 0.05) equally; there were no major differences between nonfailing and failing myocardium at each respective length (P > 0.05), indicating that this regulatory mechanism is preserved in heart failure. Length-dependent assessment of twitch kinetics mirrored these findings; normalized dF/dt slowed down with increasing length of the muscle and was virtually identical in diseased tissue. This study shows for the first time that muscle length regulates cross-bridge kinetics in human myocardium under near-physiological conditions and that those kinetics are preserved in the right ventricular tissues of heart failure patients. Copyright © 2015 the American Physiological Society.
Effect of Inhalation of Lavender Essential Oil on Vital Signs in Open Heart Surgery ICU.
Salamati, Armaiti; Mashouf, Soheyla; Mojab, Faraz
2017-01-01
This study evaluated the effects of inhalation of Lavender essential oil on vital signs in open heart surgery ICU. The main complaint of patients after open-heart surgery is dysrhythmia, tachycardia, and hypertension due to stress and pain. Due to the side effects of chemical drugs, such as opioids, use of non-invasive methods such as aromatherapy for relieving stress and pain parallel to chemical agents could be an important way to decrease the dose and side effects of analgesics. In a multicenter, single-blind trial, 40 patients who had open-heart surgery were recruited. Inclusion criteria were full consciousness, lack of hemorrhage, heart rate >60 beats/min, systolic blood pressure > 100 mmHg, and diastolic blood pressure > 60 mmHg, not using beta blockers in the operating room or ICU, no history of addiction to opioids or use of analgesics in regular, spontaneous breathing ability and not receiving synthetic opioids within 2 h before extubation. Ten minutes after extubation, the patients› vital signs [including BP, HR, Central Venous Pressure (CVP), SPO2, and RR] were measured. Then, a cotton swab, which was impregnated with 2 drops of Lavender essential oil 2%, was placed in patients' oxygen mask and patients breathed for 10 min. Thirty minutes after aromatherapy, the vital signs were measured again. Main objective of this study was the change in vital sign before and after aromatherapy. Statistical significance was accepted for P < 0.05. There was a significant difference in systolic blood pressure (p > 0.001), diastolic blood pressure (p = 0.001), and heart rate (p = 0.03) before and after the intervention using paired t-test. Although, the results did not show any significant difference in respiratory rate (p = 0.1), SpO2 (p = 0.5) and CVP (p = 0.2) before and after inhaling Lavender essential oil. Therefore, the aromatherapy could effectively reduce blood pressure and heart rate in patients admitted to the open heart surgery ICU and can be used as an independent nursing intervention in stabilizing mentioned vital signs. The limitations of our study were sample size and lack of control group. Randomized clinical trials with larger sample size are recommended.
Multiscale power analysis for heart rate variability
NASA Astrophysics Data System (ADS)
Zeng, Peng; Liu, Hongxing; Ni, Huangjing; Zhou, Jing; Xia, Lan; Ning, Xinbao
2015-06-01
We first introduce multiscale power (MSP) method to assess the power distribution of physiological signals on multiple time scales. Simulation on synthetic data and experiments on heart rate variability (HRV) are tested to support the approach. Results show that both physical and psychological changes influence power distribution significantly. A quantitative parameter, termed power difference (PD), is introduced to evaluate the degree of power distribution alteration. We find that dynamical correlation of HRV will be destroyed completely when PD>0.7.
Han, Lin; Li, Ji P; Sit, Janet W H; Chung, Loretta; Jiao, Zuo Y; Ma, Wei G
2010-04-01
To examine the effects of music intervention on the physiological stress response and the anxiety level among mechanically ventilated patients in intensive care unit. Despite the fact that previous studies have found music interventions to be effective in stress and anxiety reduction, effects of music on the Chinese population are inconclusive and warranted systematic study to evaluate its effect fully for a different Asian culture. A randomised placebo-controlled trial. A total of 137 patients receiving mechanical ventilation were randomly assigned to either music listening group, headphone group or control group. Outcome measures included the Chinese version of Spielberger State-Trait Anxiety Scale and physiological parameters (heart rate, respiratory rate, saturation of oxygen and blood pressure). Comparison of mean differences (pretest score-posttest score) showed significant differences in heart rate, respiratory rate, systolic blood pressure and diastolic blood pressure as well as the Chinese version of Spielberger State-Trait Anxiety Scale, but not in SaO(2) among the three groups (ranging from p < 0.001 to p = 0.007), of which greater mean differences were found in music listening group. A significant reduction in physiological stress response (heart rate and respiratory rate) over time was found in music listening group (p < 0.001 for both variables) and a significant increase in heart rate and respiratory rate over time in control group (p < 0.001 and p = 0.032), with no significant change over time in headphone group. Within group pretest-posttest comparison of the Chinese version of Spielberger State-Trait Anxiety Scale demonstrated a significant reduction in anxiety for the music listening group (p < 0.001) and headphone group (p < 0.001) but not the control group. Our findings confirm that short-term therapeutic effects of music listening results in substantial reduction in physiological stress responses arising from anxiety in mechanically ventilated patients. Music as a non-pharmacological nursing intervention can be used as complementary adjunct in the care of patients with low-energy states who tire easily, such as those requiring mechanical ventilator support.
Olkowski, A A; Nain, S; Wojnarowicz, C; Laarveld, B; Alcorn, J; Ling, B B
2007-09-01
In order to explain the biochemical mechanisms associated with deteriorating heart function in broiler chickens, this study compared myocardial high energy phosphate substrates in leghorns, feed restricted (Broilers-Res) broilers, ad libitum fed broilers (Broilers-AL), and in broilers that developed heart failure and ascites. The profile of adenine nucleotide content in the heart tissue did not differ between leghorns and Broilers-Res, but there were significant differences among Broilers-Res, Broilers-AL, and broilers with ascites. During intensive growth periods, leghorns and Broilers-Res showed increasing trends in heart ATP levels, whereas in fast growing broilers the heart ATP declined (p<0.021). ATP:ADP and ATP:CrP ratios increased with age in both leghorn and Broilers-Res, declined in fast growing broilers, and were the lowest in broilers that developed heart failure. The changes in heart high energy phosphate profile in broilers suggest that the energy demand of the heart during a rapid growth phase may exceed the bird's metabolic capacity to supply adequate levels of high energy phosphate substrate. The insufficiency of energy substrate likely contributes to the declining heart rate. In some individuals this may lead to impaired heart pump function, and in more severe cases may progress to heart pump failure.
Becker-Birck, M; Schmidt, A; Wulf, M; Aurich, J; von der Wense, A; Möstl, E; Berz, R; Aurich, C
2013-04-01
Bringing the head and neck of ridden horses into a position of hyperflexion is widely used in equestrian sports. In our study, the hypothesis was tested that hyperflexion is an acute stressor for horses. Salivary cortisol concentrations, heart rate, heart rate variability (HRV) and superficial body temperature were determined in horses (n = 16) lunged on two subsequent days. The head and neck of the horse was fixed with side reins in a position allowing forward extension on day A and fixed in hyperflexion on day B. The order of treatments alternated between horses. In response to lunging, cortisol concentration increased (day A from 0.73 ± 0.06 to 1.41 ± 0.13 ng/ml, p < 0.001; day B from 0.68 ± 0.07 to 1.38 ± 0.13 ng/ml, p < 0.001) but did not differ between days A and B. Beat-to-beat (RR) interval decreased in response to lunging on both days. HRV variables standard deviation of RR interval (SDRR) and RMSSD (root mean square of successive RR differences) decreased (p < 0.001) but did not differ between days. In the cranial region of the neck, the difference between maximum and minimum temperature was increased in hyperflexion (p < 0.01). In conclusion, physiological parameters do not indicate an acute stress response to hyperflexion of the head alone in horses lunged at moderate speed and not touched with the whip. However, if hyperflexion is combined with active intervention of a rider, a stressful experience for the horse cannot be excluded. © 2012 Blackwell Verlag GmbH.
Side effects and complications of intraosseous anesthesia and conventional oral anesthesia
Peñarrocha-Oltra, David; Ata-Ali, Javier; Oltra-Moscardó, María J.; Peñarrocha, Miguel
2012-01-01
Objective: To analyze the side effects and complications following intraosseous anesthesia (IA), comparing them with those of the conventional oral anesthesia techniques. Material and method: A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for respective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. Heart rate was recorded in all cases before injection of the anesthetic solution and again 30 seconds after injection. The complications observed after anesthetic administration were recorded. Results: A total of 200 oral anesthetic procedures were carried out in 100 patients. Both IA and conventional anesthesia resulted in a significant increase in heart rate, though the increase was greater with the latter technique. Incidents were infrequent with either anesthetic technique, with no significant differences between them. Regarding the complications, there were significant differences in pain at the injection site, with more intense pain in the case of IA (x2=3.532, p=0.030, Φ2=0.02), while the limitation of oral aperture was more pronounced with conventional anesthesia (x2=5.128, p<0.05, Φ2=0.014). Post-anesthetic biting showed no significant differences (x2=4.082, p=0.121, Φ2=0.009). Conclusions: Both anesthetic techniques significantly increased heart rate, and IA caused comparatively more pain at the injection site, while limited oral aperture was more frequent with conventional anesthesia. Post-anesthetic biting showed no significant differences between the two techniques. Key words:Intraosseous anesthesia, oral anesthesia, mandibular block, heart rate, adrenalin, complications. PMID:22143716
Lee, Elisa T.; Peterson, Leif E.; Devereux, Richard B.; Rhoades, Everett R.; Umans, Jason G.; Best, Lyle G.; Howard, William J.; Paranilam, Jaya; Howard, Barbara V.
2012-01-01
Context: Coronary heart disease (CHD) is the leading cause of death in the United States. Objective: This study compares differences in risk factors for CHD in diabetic vs. nondiabetic Strong Heart Study participants. Design: This was an observational study. Setting: The study was conducted at three centers in Arizona, Oklahoma, and North and South Dakota. Participants: Data were obtained from 3563 of 4549 American Indians free of cardiovascular disease at baseline. Intervention(s): CHD events were ascertained during follow-up. Main Outcome Measure: CHD events were classified using standardized criteria. Results: In diabetic and nondiabetic participants, 545 and 216 CHD events, respectively, were ascertained during follow-up (21,194 and 22,990 person-years); age- and sex-adjusted incidence rates of CHD were higher for the diabetic group (27.5 vs. 12.1 per 1,000 person-years). Risk factors for incident CHD common to both groups included older age, male sex, prehypertension or hypertension, and elevated low-density lipoprotein cholesterol. Risk factors specific to the diabetic group were lower high-density lipoprotein cholesterol, current smoking, macroalbuminuria, lower estimated glomerular filtration rate, use of diabetes medication, and longer duration of diabetes. Higher body mass index was a risk factor only for the nondiabetic group. The association of male sex and CHD was greater in those without diabetes than in those with diabetes. Conclusions: In addition to higher incidence rates of CHD events in persons with diabetes compared with those without, the two groups differed in CHD risk factors. These differences must be recognized in estimating CHD risk and managing risk factors. PMID:22802089
Kyriacou, Andreas; Li Kam Wa, Matthew E; Pabari, Punam A; Unsworth, Beth; Baruah, Resham; Willson, Keith; Peters, Nicholas S; Kanagaratnam, Prapa; Hughes, Alun D; Mayet, Jamil; Whinnett, Zachary I; Francis, Darrel P
2013-08-10
In atrial fibrillation (AF), VV optimization of biventricular pacemakers can be examined in isolation. We used this approach to evaluate internal validity of three VV optimization methods by three criteria. Twenty patients (16 men, age 75 ± 7) in AF were optimized, at two paced heart rates, by LVOT VTI (flow), non-invasive arterial pressure, and ECG (minimizing QRS duration). Each optimization method was evaluated for: singularity (unique peak of function), reproducibility of optimum, and biological plausibility of the distribution of optima. The reproducibility (standard deviation of the difference, SDD) of the optimal VV delay was 10 ms for pressure, versus 8 ms (p=ns) for QRS and 34 ms (p<0.01) for flow. Singularity of optimum was 85% for pressure, 63% for ECG and 45% for flow (Chi(2)=10.9, p<0.005). The distribution of pressure optima was biologically plausible, with 80% LV pre-excited (p=0.007). The distributions of ECG (55% LV pre-excitation) and flow (45% LV pre-excitation) optima were no different to random (p=ns). The pressure-derived optimal VV delay is unaffected by the paced rate: SDD between slow and fast heart rate is 9 ms, no different from the reproducibility SDD at both heart rates. Using non-invasive arterial pressure, VV delay optimization by parabolic fitting is achievable with good precision, satisfying all 3 criteria of internal validity. VV optimum is unaffected by heart rate. Neither QRS minimization nor LVOT VTI satisfy all validity criteria, and therefore seem weaker candidate modalities for VV optimization. AF, unlinking interventricular from atrioventricular delay, uniquely exposes resynchronization concepts to experimental scrutiny. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Alberton, C L; Kanitz, A C; Pinto, S S; Antunes, A H; Finatto, P; Cadore, E L; Kruel, L F M
2013-08-01
The aim of this study was to compare the cardiorespiratory variables corresponding to the anaerobic threshold (AT) between different water-based exercises using two methods of determining the AT, the heart rate deflection point and ventilatory method, and to correlate the variables in both methods. Twenty young women performed three exercise sessions in the water. Maximal tests were performed in the water-based exercises stationary running, frontal kick and cross country skiing. The protocol started at a rate of 80 cycles per minute (cycle.min-1) for 2 min with subsequent increments of 10 cycle.min-1 every minute until exhaustion, with measurements of heart rate, oxygen uptake and ventilation throughout test. After, the two methods were used to determine the values of these variables corresponding to the AT for each of the exercises. Comparisons were made using two-way ANOVA for repeated measures with Bonferroni's post hoc test. To correlate the same variables determined by the two methods, the intra-class correlation coefficient test (ICC) was used. For all the variables, no significant differences were found between the methods of determining the AT and the three exercises. Moreover, the ICC values of each variable determined by the two methods were high and significant. The estimation of the heart rate deflection point can be used as a simple and practical method of determining the AT, which can be used when prescribing these exercises. In addition, these cardiorespiratory parameters may be determined performing the test with only one of the evaluated exercises, since there were no differences in the evaluated variables.
Behavioral correlates of heart rates of free-living Greater White-fronted Geese
Ely, Craig R.; Ward, D.H.; Bollinger, K.S.
1999-01-01
We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged < 10 sec. During agonistic encounters, heart rate exceeded 400 BPM; heart rates during social interactions were not predictable solely from postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.
Physiology responses of Rhesus monkeys to vibration
NASA Astrophysics Data System (ADS)
Hajebrahimi, Zahra; Ebrahimi, Mohammad; Alidoust, Leila; Arabian Hosseinabadi, Maedeh
Vibration is one of the important environmental factors in space vehicles that it can induce severe physiological responses in most of the body systems such as cardiovascular, respiratory, skeletal, endocrine, and etc. This investigation was to assess the effect of different vibration frequencies on heart rate variability (HRV), electrocardiograms (ECG) and respiratory rate in Rhesus monkeys. Methods: two groups of rhesus monkey (n=16 in each group) was selected as control and intervention groups. Monkeys were held in a sitting position within a specific fixture. The animals of this experiment were vibrated on a table which oscillated right and left with sinusoidal motion. Frequency and acceleration for intervention group were between the range of 1 to 2000 Hz and +0.5 to +3 G during 36 weeks (one per week for 15 min), respectively. All of the animals passed the clinical evaluation (echocardiography, sonography, radiography and blood analysis test) before vibration test and were considered healthy and these tests repeated during and at the end of experiments. Results and discussions: Our results showed that heart and respiratory rates increased significantly in response to increased frequency from 1 to 60 Hz (p <0.05) directly with the +G level reaching a maximum (3G) within a seconds compare to controls. There were no significant differences in heart and respiratory rate from 60 t0 2000 Hz among studied groups. All monkeys passed vibration experiment successfully without any arrhythmic symptoms due to electrocardiography analysis. Conclusion: Our results indicate that vibration in low frequency can effect respiratory and cardiovascular function in rhesus monkey. Keywords: Vibration, rhesus monkey, heart rate, respiratory rate
The Accuracy and Validity of iOS-Based Heart Rate Apps During Moderate to High Intensity Exercise.
Bouts, Alexa M; Brackman, Lauren; Martin, Elizabeth; Subasic, Adam M; Potkanowicz, Edward S
2018-01-01
People use their smartphones for everything from web browsing to tracking fitness metrics. However, it is unclear whether smartphone-based apps that use photoplethysmography to measure heart rate are an accurate or valid measure of exercise intensity. Purpose was to determine the accuracy and validity of two iOS-based heart rate monitors, Runtastic Heart Rate Monitor and Pulse Tracker PRO by Runtastic (Runtastic) and Instant Heart Rate+: Heart Rate and Pulse Monitor by Azumio (Instant Heart Rate), when compared to the electrocardiogram (ECG) and Polar® T31 uncoded heart rate monitor from moderate to vigorous intensity exercise. Participants were 15 male and female regularly active college students. Pre-exercise heart rate and blood pressure were recorded and then participants exercised on a stationary bike at a pedal rate of between 50-60 rpms. After completing a warm-up stage at 40% of age estimated maximum heart rate (AEMHR), exercise intensity progressed from 50% of AEMHR through to 85% of AEMHR in eight, 5-minute stages. At the end of each stage, and having achieved steady-state, heart rates were recorded from each apparatus. After completing the final stage, participants completed a cooldown at 40% of their AEMHR. Post-exercise heart rate and blood pressure were also recorded to ensure full recovery to baseline. There was a strong positive correlation between the Polar® monitor and the ECG during all stages. However, there were not strong correlations for either of the smartphone-based apps at any time point. Although there were weak correlations between the smartphone-based apps and ECG and Polar®, further studies need to be conducted to determine if inaccuracy is due to user error (finger placement, finger temperature, etc.) or the technology behind the apps.
The Accuracy and Validity of iOS-Based Heart Rate Apps During Moderate to High Intensity Exercise
BOUTS, ALEXA M.; BRACKMAN, LAUREN; MARTIN, ELIZABETH; SUBASIC, ADAM M.; POTKANOWICZ, EDWARD S.
2018-01-01
People use their smartphones for everything from web browsing to tracking fitness metrics. However, it is unclear whether smartphone-based apps that use photoplethysmography to measure heart rate are an accurate or valid measure of exercise intensity. Purpose was to determine the accuracy and validity of two iOS-based heart rate monitors, Runtastic Heart Rate Monitor and Pulse Tracker PRO by Runtastic (Runtastic) and Instant Heart Rate+: Heart Rate and Pulse Monitor by Azumio (Instant Heart Rate), when compared to the electrocardiogram (ECG) and Polar® T31 uncoded heart rate monitor from moderate to vigorous intensity exercise. Participants were 15 male and female regularly active college students. Pre-exercise heart rate and blood pressure were recorded and then participants exercised on a stationary bike at a pedal rate of between 50–60 rpms. After completing a warm-up stage at 40% of age estimated maximum heart rate (AEMHR), exercise intensity progressed from 50% of AEMHR through to 85% of AEMHR in eight, 5-minute stages. At the end of each stage, and having achieved steady-state, heart rates were recorded from each apparatus. After completing the final stage, participants completed a cooldown at 40% of their AEMHR. Post-exercise heart rate and blood pressure were also recorded to ensure full recovery to baseline. There was a strong positive correlation between the Polar® monitor and the ECG during all stages. However, there were not strong correlations for either of the smartphone-based apps at any time point. Although there were weak correlations between the smartphone-based apps and ECG and Polar®, further studies need to be conducted to determine if inaccuracy is due to user error (finger placement, finger temperature, etc.) or the technology behind the apps. PMID:29541341
Role of Biofeedback in Optimizing Psychomotor Performance in Sports
Paul, Maman; Garg, Kanupriya; Singh Sandhu, Jaspal
2012-01-01
Purpose Biofeedback is an emerging tool to acquire and facilitate physiological and psychological domains of the human body like response time and concentration. Thus, the present study aims at determining the reconstitution of psychomotor and performance skills in basketball players through biofeedback training. Methods Basketball players (N=30) with different levels of expertise (university, state and national) aged 18-28 years (both male and female) were randomly divided into 3 equal groups - Experimental group, Placebo group and Control group. The experimental group received Heart Rate Variability Biofeedback training for 10 consecutive days for 20 minutes that included breathing at individual's resonant frequency through a pacing stimulus; Placebo group was shown motivational video clips for 10 consecutive days for 10 minutes, whereas Control group was not given any intervention. At session 1, 10 and 1month follow up, heart rate variability, respiration rate, response time (reaction and movement time), concentration and shooting performance were assessed. Results Two way repeated measure ANOVA was used to simultaneously compare within and between group differences. Response time, concentration, heart rate variability, respiration rate and shooting differences were statistically significant in each group along with interaction of group and time (P<0.001). Also, all the measures showed statistically significant inter group difference (P<0.05). Conclusion The results of the study suggest that biofeedback training may help to train stressed athletes to acquire a control over their psychophysiological processes, thus helping an athlete to perform maximally. PMID:22461963
Patterns of Sympathetic Responses Induced by Different Stress Tasks
Fechir, M; Schlereth, T; Purat, T; Kritzmann, S; Geber, C; Eberle, T; Gamer, M; Birklein, F
2008-01-01
Stress tasks are used to induce sympathetic nervous system (SNS) arousal. However, the efficacy and the patterns of SNS activation have not been systematically compared between different tasks. Therefore, we analyzed SNS activation during the following stress tasks: Presentation of negative, positive, and – as a control – neutral affective pictures, Color-Word interference test (CWT), mental arithmetic under time limit, singing a song aloud, and giving a spontaneous talk. We examined 11 healthy subjects and recorded the following SNS parameters: Activation of emotional sweating by quantitative sudometry, skin vasoconstriction by laser-Doppler flowmetry, heart rate by ECG, blood pressure by determination of pulse wave transit time (PWTT), and electromyographic (EMG) activity of the trapezius muscle. Moreover, subjective stress ratings were acquired for each task using a visual analog scale. All tasks were felt significantly stressful when compared to viewing neutral pictures. However, SNS activation was not reliable: Affective pictures did not induce a significant SNS response; singing, giving a talk and mental arithmetic selectively increased heart rate and emotional sweating. Only the CWT globally activated the SNS. Regarding all tasks, induction of emotional sweating, increase of heart rate and blood pressure significantly correlated with subjective stress ratings, in contrast to EMG and skin vasoconstriction. Our results show that the activation of the SNS widely varies depending on the stress task. Different stress tasks differently activate the SNS, which is an important finding when considering sympathetic reactions - in clinical situations and in research. PMID:19018304
Implementation of a wireless sensor network for heart rate monitoring in a senior center.
Huang, Jyh-How; Su, Tzu-Yao; Raknim, Paweeya; Lan, Kun-Chan
2015-06-01
Wearable sensor systems are widely used to monitor vital sign in hospitals and in recent years have also been used at home. In this article we present a system that includes a ring probe, sensor, radio, and receiver, designed for use as a long-term heart rate monitoring system in a senior center. The primary contribution of this article is successfully implementing a cheap, large-scale wireless heart rate monitoring system that is stable and comfortable to use 24 h a day. We developed new finger ring sensors for comfortable continuous wearing experience and used dynamic power adjustment on the ring so the sensor can detect pulses at different strength levels. Our system has been deployed in a senior center since May 2012, and 63 seniors have used this system in this period. During the 54-h system observation period, 10 alarms were set off. Eight of them were due to abnormal heart rate, and two of them were due to loose probes. The monitoring system runs stably with the senior center's existing WiFi network, and achieves 99.48% system availability. The managers and caregivers use our system as a reliable warning system for clinical deterioration. The results of the year-long deployment show that the wireless group heart rate monitoring system developed in this work is viable for use within a designated area.
... or a heart function test. What's a Normal Heart Rate? Heart rate is measured by counting the number of beats per minute. Someone's normal heart rate depends on things like the person's age and ...
Jones, Peter; Ovenden, Nick; Dauger, Stéphane; Peters, Mark J
2014-01-01
Reductions in heart rate occur frequently in children during critical care intubation and are currently considered the gold standard for haemodynamic instability. Our objective was to estimate loss of heart beats during intubation and compare this to reduction in heart rate alone whilst testing the impact of atropine pre-medication. Data were extracted from a prospective 2-year cohort study of intubation ECGs from critically ill children in PICU/Paediatric Transport. A three step algorithm was established to exclude variation in pre-intubation heart rate (using a 95%CI limit derived from pre-intubation heart rate variation of the children included), measure the heart rate over time and finally the estimate the numbers of lost beats. 333 intubations in children were eligible for inclusion of which 245 were available for analysis (74%). Intubations where the fall in heart rate was less than 50 bpm were accompanied almost exclusively by less than 25 lost beats (n = 175, median 0 [0-1]). When there was a reduction of >50 bpm there was a poor correlation with numbers of lost beats (n = 70, median 42 [15-83]). During intubation the median number of lost beats was 8 [1]-[32] when atropine was not used compared to 0 [0-0] when atropine was used (p<0.001). A reduction in heart rate during intubation of <50 bpm reliably predicted a minimal loss of beats. When the reduction in heart rate was >50 bpm the heart rate was poorly predictive of lost beats. A study looking at the relationship between lost beats and cardiac output needs to be performed. Atropine reduces both fall in heart rate and loss of beats. Similar area-under-the-curve methodology may be useful for estimating risk when biological parameters deviate outside normal range.
Zhao, R-C; Han, W; Han, J; Yu, J; Guo, J; Fu, J-L; Li, Z; Zhao, R-Z
2016-10-01
To study the efficacy and safety of radiofrequency catheter ablation (RFCA) in patients with different forms of atrial fibrillation. By retrospective analysis, we summarize 720 cases, where patients diagnosed with atrial fibrillation in our hospital were treated with RFCA from February 2010 to October 2014. Among the cases, 425 were diagnosed with paroxysmal atrial fibrillation and 295 with non-paroxysmal atrial fibrillation (including persistent atrial fibrillation and permanent atrial fibrillation). All patients were followed up until June 2015 to compare and analyze the differences in operation success rates, complications and recurrence rates. 395 cases (92.9%) of paroxysmal atrial fibrillation and 253 cases (85.8%) with non-paroxysmal atrial fibrillation were subject to surgery and followed up. The age of onset, disease course, underlying diseases, left atrial diameter and combined anti-arrhythmics of patients with paroxysmal atrial fibrillation were lower than those of patients with non-paroxysmal atrial fibrillation, and the differences were statistically significant (p < 0.05). The success rate of the first ablation was higher than that of non-paroxysmal atrial fibrillation. Procedure time, procedure method, complications and recurrence rate of patients with paroxysmal atrial fibrillation were lower than those of non-paroxysmal atrial fibrillation group, and the differences were statistically significant (p < 0.05). When we compared apoplexy and heart failure caused by atrial fibrillation in the two groups, the difference was not statistically significant (Apoplexy: p = 0.186; Heart failure: p = 0.170). The individual ablation success rate was higher for paroxysmal atrial fibrillation, and long-term follow-up showed that the occurrence of apoplexy and heart failure was not different from the non-paroxysmal atrial fibrillation group.
Woo, M A; Moser, D K; Stevenson, L W; Stevenson, W G
1997-09-01
The 6-minute walk and heart rate variability have been used to assess mortality risk in patients with heart failure, but their relationship to each other and their usefulness for predicting mortality at 1 year are unknown. To assess the relationships between the 6-minute walk test, heart rate variability, and 1-year mortality. A sample of 113 patients in advanced stages of heart failure (New York Heart Association Functional Class III-IV, left ventricular ejection < 0.25) were studied. All 6-minute walks took place in an enclosed, level, measured corridor and were supervised by the same nurse. Heart rate variability was measured by using (1) a standard-deviation method and (2) Poincaré plots. Data on RR intervals obtained by using 24-hour Holter monitoring were analyzed. Survival was determined at 1 year after the Holter recording. The results showed no significant associations between the results of the 6-minute walk and the two measures of heart rate variability. The results of the walk were related to 1-year mortality but not to the risk of sudden death. Both measures of heart rate variability had significant associations with 1-year mortality and with sudden death. However, only heart rate variability measured by using Poincaré plots was a predictor of total mortality and risk of sudden death, independent of left ventricular ejection fraction, serum levels of sodium, results of the 6-minute walk test, and the standard-deviation measure of heart rate variability. Results of the 6-minute walk have poor association with mortality and the two measures of heart rate variability in patients with advanced-stage heart failure and a low ejection fraction. Further studies are needed to determine the optimal clinical usefulness of the 6-minute walk and heart rate variability in patients with advanced-stage heart failure.
Geyer, Siegfried; Norozi, Kambiz; Buchhorn, Reiner; Wessel, Armin
2009-01-01
It was examined whether women and men (17-45 years) with operated congenital heart disease differ with respect to chances of employment. Patients were compared with the general population. Patients (n = 314) were classified by type of surgery (curative, reparative, palliative) as indicator of initial severity of disease. The second classification was performed according to a system proposed by the New York Heart Association in order to take reported impairments into account. Controls (n = 1165) consisted of a 10% random sample drawn from the German Socio-Economic Panel. Chances of full-time employment decreased as disease severity increased. Chances of part-time and minor employment were higher in patients than among controls. These general effects were because of male patients, while the employment patterns of women did not differ from the control group. Independent of patient status, women were more likely to have lower rates of full-time employment, and the rates of part-time and minor employment were higher. Long-term adaptation to impairments as a result of congenital heart disease differs between women and men with respect to employment status. While female patients do not differ from the general population, males may lower their engagement in paid work.
Variability in heart rate recovery measurements over 1 year in healthy, middle-aged adults.
Mellis, M G; Ingle, L; Carroll, S
2014-02-01
This study assessed the longer-term (12-month) variability in post-exercise heart rate recovery following a submaximal exercise test. Longitudinal data was analysed for 97 healthy middle-aged adults (74 male, 23 female) from 2 occasions, 12 months apart. Participants were retrospectively selected if they had stable physical activity habits, submaximal treadmill fitness and anthropometric measurements between the 2 assessment visits. A submaximal Bruce treadmill test was performed to at least 85% age-predicted maximum heart rate. Absolute heart rate and Δ heart rate recovery (change from peak exercise heart rate) were recorded for 1 and 2 min post-exercise in an immediate supine position. Heart rate recovery at both time-points was shown to be reliable with intra-class correlation coefficient values ≥ 0.714. Absolute heart rate 1-min post-exercise showed the strongest agreement between repeat tests (r = 0.867, P < 0.001). Lower coefficient of variation (≤ 10.2%) and narrower limits of agreement were found for actual heart rate values rather than Δ heart rate recovery, and for 1-min rather than 2-min post-exercise recovery time points. Log-transformed values generated better variability with acceptable coefficient of variation for all measures (2.2-10%). Overall, 1 min post-exercise heart rate recovery data had least variability over the 12-month period in apparently healthy middle-aged adults. © Georg Thieme Verlag KG Stuttgart · New York.