Sample records for heating substation efficiency

  1. Independent Power Generation in a Modern Electrical Substation Based on Thermoelectric Technology

    NASA Astrophysics Data System (ADS)

    Li, Z. M.; Zhao, Y. Q.; Liu, W.; Wei, B.; Qiu, M.; Lai, X. K.

    2017-05-01

    Because of many types of electrical equipment with high power in substations, the potentiality of energy conservation is quite large. From this viewpoint, thermoelectric materials may be chosen to produce electrical energy using the waste heat produced in substations. Hence, a thermoelectric generation system which can recycle the waste heat from electric transformers was proposed to improve the energy efficiency and reduce the burden of the oil cooling system. An experimental prototype was fabricated to perform the experiment and to verify the feasibility. The experimental results showed that the output power could achieve 16 W from waste heat of 900 W, and that the power conversion efficiency was approximately 1.8%. Therefore, power generation is feasible by using the waste heat from the transformers based on thermoelectric technology.

  2. A new test procedure to evaluate the performance of substations for collective heating systems

    NASA Astrophysics Data System (ADS)

    Baetens, Robin; Verhaert, Ivan

    2017-11-01

    The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  3. An application of data mining in district heating substations for improving energy performance

    NASA Astrophysics Data System (ADS)

    Xue, Puning; Zhou, Zhigang; Chen, Xin; Liu, Jing

    2017-11-01

    Automatic meter reading system is capable of collecting and storing a huge number of district heating (DH) data. However, the data obtained are rarely fully utilized. Data mining is a promising technology to discover potential interesting knowledge from vast data. This paper applies data mining methods to analyse the massive data for improving energy performance of DH substation. The technical approach contains three steps: data selection, cluster analysis and association rule mining (ARM). Two-heating-season data of a substation are used for case study. Cluster analysis identifies six distinct heating patterns based on the primary heat of the substation. ARM reveals that secondary pressure difference and secondary flow rate have a strong correlation. Using the discovered rules, a fault occurring in remote flow meter installed at secondary network is detected accurately. The application demonstrates that data mining techniques can effectively extrapolate potential useful knowledge to better understand substation operation strategies and improve substation energy performance.

  4. Application of service oriented architecture for sensors and actuators in district heating substations.

    PubMed

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-08-21

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation.

  5. Application of Service Oriented Architecture for Sensors and Actuators in District Heating Substations

    PubMed Central

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-01-01

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation. PMID:25196165

  6. Making the Connection: Beneficial Collaboration Between Army Installations and Energy Utility Companies

    DTIC Science & Technology

    2011-01-01

    natural gas vehicle-fueling station, improving the efficiency of boilers, installing a generating system to supplement the electricity purchased during...voltage regulation of transformers in its substations to improve energy efficiency and a small study on customer assistance, both at BPA’s own expense...Fort Campbell has installed more energy efficient boilers, HVAC systems , hot water heaters, lighting, 10 A ground source heat pump (GSHP), also

  7. Application of Superconducting Power Cables to DC Electric Railway Systems

    NASA Astrophysics Data System (ADS)

    Ohsaki, Hiroyuki; Lv, Zhen; Sekino, Masaki; Tomita, Masaru

    For novel design and efficient operation of next-generation DC electric railway systems, especially for their substantial energy saving, we have studied the feasibility of applying superconducting power cables to them. In this paper it is assumed that a superconducting power cable is applied to connect substations supplying electric power to trains. An analysis model line was described by an electric circuit, which was analyzed with MATLAB-Simulink. From the calculated voltages and currents of the circuit, the regenerative brake and the energy losses were estimated. In addition, assuming the heat loads of superconducting power cables and the cryogenic efficiency, the energy saving of the total system was evaluated. The results show that the introduction of superconducting power cables could achieve the improved use of regenerative brake, the loss reduction, the decreased number of substations, the reduced maintenance, etc.

  8. DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharya, Saptarshi; Chandan, Vikas; Arya, Vijay

    In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models ofmore » individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.« less

  9. Advanced concepts and solutions for geothermal heating applied in Oradea, Romania

    NASA Astrophysics Data System (ADS)

    Antal, C.; Popa, F.; Mos, M.; Tigan, D.; Popa, B.; Muresan, V.

    2017-01-01

    Approximately 70% of the total population of Oradea benefits from centralized heating, about 55,000 apartments and 159,000 inhabitants are connected. The heating system of Oradea consists of: sources of thermal energy production (Combined heat and power (CHP) I Oradea and geothermal water heating plants); a transport network of heat; heat distribution network for heating and domestic hot water; substations, most of them equipped with worn and obsolete equipment. Recently, only a few heat exchangers were rehabilitated and electric valves were installed to control the water flow. After heat extraction, geothermal chilled waters from the Oradea area are: discharged into the sewer system of the city, paying a fee to the local water company which manages the city’s sewers; discharged into the small river Peta; or re-injected into the reservoir. In order to ensure environmental protection and a sustainable energy development in Oradea, renewable sources of energy have been promoted in recent years. In this respect, the creation of a new well for geothermal water re-injection into the reservoir limits any accidental thermal pollution of the environment, while ensuring the conservation properties of the aquifer by recharging with geothermal chilled water. The paper presents the achievements of such a project whose aim is to replace thermal energy obtained from coal with geothermal heating. The novelty consists in the fact that within the substation we will replace old heat exchangers, circulation pumps and valves with fully automated substations operating in parallel on both a geothermal system and on a primary heating system of a thermal plant.

  10. Study on Noise Prediction Model and Control Schemes for Substation

    PubMed Central

    Gao, Yang; Liu, Songtao

    2014-01-01

    With the government's emphasis on environmental issues of power transmission and transformation project, noise pollution has become a prominent problem now. The noise from the working transformer, reactor, and other electrical equipment in the substation will bring negative effect to the ambient environment. This paper focuses on using acoustic software for the simulation and calculation method to control substation noise. According to the characteristics of the substation noise and the techniques of noise reduction, a substation's acoustic field model was established with the SoundPLAN software to predict the scope of substation noise. On this basis, 4 reasonable noise control schemes were advanced to provide some helpful references for noise control during the new substation's design and construction process. And the feasibility and application effect of these control schemes can be verified by using the method of simulation modeling. The simulation results show that the substation always has the problem of excessive noise at boundary under the conventional measures. The excess noise can be efficiently reduced by taking the corresponding noise reduction methods. PMID:24672356

  11. ESTIMATING RISK TO CALIFORNIA ENERGY INFRASTRUCTURE FROM PROJECTED CLIMATE CHANGE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sathaye, Jayant; Dale, Larry; Larsen, Peter

    2011-06-22

    This report outlines the results of a study of the impact of climate change on the energy infrastructure of California and the San Francisco Bay region, including impacts on power plant generation; transmission line and substation capacity during heat spells; wildfires near transmission lines; sea level encroachment upon power plants, substations, and natural gas facilities; and peak electrical demand. Some end-of-century impacts were projected:Expected warming will decrease gas-fired generator efficiency. The maximum statewide coincident loss is projected at 10.3 gigawatts (with current power plant infrastructure and population), an increase of 6.2 percent over current temperature-induced losses. By the end ofmore » the century, electricity demand for almost all summer days is expected to exceed the current ninetieth percentile per-capita peak load. As much as 21 percent growth is expected in ninetieth percentile peak demand (per-capita, exclusive of population growth). When generator losses are included in the demand, the ninetieth percentile peaks may increase up to 25 percent. As the climate warms, California's peak supply capacity will need to grow faster than the population.Substation capacity is projected to decrease an average of 2.7 percent. A 5C (9F) air temperature increase (the average increase predicted for hot days in August) will diminish the capacity of a fully-loaded transmission line by an average of 7.5 percent.The potential exposure of transmission lines to wildfire is expected to increase with time. We have identified some lines whose probability of exposure to fire are expected to increase by as much as 40 percent. Up to 25 coastal power plants and 86 substations are at risk of flooding (or partial flooding) due to sea level rise.« less

  12. Efficient evaluation of sampling quality of molecular dynamics simulations by clustering of dihedral torsion angles and Sammon mapping.

    PubMed

    Frickenhaus, Stephan; Kannan, Srinivasaraghavan; Zacharias, Martin

    2009-02-01

    A direct conformational clustering and mapping approach for peptide conformations based on backbone dihedral angles has been developed and applied to compare conformational sampling of Met-enkephalin using two molecular dynamics (MD) methods. Efficient clustering in dihedrals has been achieved by evaluating all combinations resulting from independent clustering of each dihedral angle distribution, thus resolving all conformational substates. In contrast, Cartesian clustering was unable to accurately distinguish between all substates. Projection of clusters on dihedral principal component (PCA) subspaces did not result in efficient separation of highly populated clusters. However, representation in a nonlinear metric by Sammon mapping was able to separate well the 48 highest populated clusters in just two dimensions. In addition, this approach also allowed us to visualize the transition frequencies between clusters efficiently. Significantly, higher transition frequencies between more distinct conformational substates were found for a recently developed biasing-potential replica exchange MD simulation method allowing faster sampling of possible substates compared to conventional MD simulations. Although the number of theoretically possible clusters grows exponentially with peptide length, in practice, the number of clusters is only limited by the sampling size (typically much smaller), and therefore the method is well suited also for large systems. The approach could be useful to rapidly and accurately evaluate conformational sampling during MD simulations, to compare different sampling strategies and eventually to detect kinetic bottlenecks in folding pathways.

  13. Characteristic Analysis of DC Electric Railway Systems with Superconducting Power Cables Connecting Power Substations

    NASA Astrophysics Data System (ADS)

    Ohsaki, H.; Matsushita, N.; Koseki, T.; Tomita, M.

    2014-05-01

    The application of superconducting power cables to DC electric railway systems has been studied. It could leads to an effective use of regenerative brake, improved energy efficiency, effective load sharing among the substations, etc. In this study, an electric circuit model of a DC feeding system is built and numerical simulation is carried out using MATLAB-Simulink software. A modified electric circuit model with an AC power grid connection taken into account is also created to simulate the influence of the grid connection. The analyses have proved that a certain amount of energy can be conserved by introducing superconducting cables, and that electric load distribution and concentration among the substations depend on the substation output voltage distribution.

  14. Experimental adoption of RCM in EDF substations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heroin, G.; Aupied, J.; Sanchis, G.

    1996-08-01

    EDF, after testing Reliability Centered Maintenance (RCM) on systems used in nuclear power plants, has now successfully extended RCM to all of its nuclear power plants. In the light of this experience, EDF has committed itself to a pilot study on a line bay of a 400 kV substation in 1992. The RCM method as applied benefited from EDF`s policy of maintenance, introduced five years ago on all substations, which has enhanced prospects of reliability. The original feature in the selection of maintenance tasks was that it brought into play two criteria for failure assessment - frequency and seriousness -more » and two criteria for maintenance task selection - efficiency and facility. The final outcome of RCM as applied to substation maintenance is to categorize maintenance tasks into: (1) essential maintenance tasks, (2) optional tasks, depending on the type and location of the substation, as well as on factors relating to local management of maintenance policy, and (3) unnecessary tasks.« less

  15. Advanced Micro Grid Energy Management Coupled with Integrated Volt/VAR Control for Improved Energy Efficiency, Energy Security, and Power Quality at DoD Installations

    DTIC Science & Technology

    2016-10-28

    constraints and wire routing issues. • Outside sites have more space, but require outdoor rated equipment (NEMA outdoor rated.. ) and more maintenance...sustainable power, in many different types, sizes and capacities, as follows: • Cogen Plant #1 B1579: 7.2MW gas-fired turbine at Substation “AA...Cogen Plant #2 B1991: (2) 4.6MW gas-fired turbines at “Gillespie” Substation • 300kW fuel cell at Substation “AA” • PPA: 1.015MW solar photovoltaic

  16. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  17. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  18. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  19. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  20. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  1. The influence of using heat storage with PCM on inlet and outlet temperatures in substation in DHS

    NASA Astrophysics Data System (ADS)

    Nogaj, Kinga; Turski, Michał; Sekret, Robert

    2017-11-01

    The main objective of this article is to indicate the direction of development of new generation heating systems that use phase change materials, and the important criteria needed when choosing a phase change material. The work contains a detailed classification of materials using the latent heat of organic and inorganic PCM. This references the technical possibilities of existing heat storage technologies. A specific objective was adopted to determine the effect of using heat storage with PCM on inlet and outlet temperatures in substation in district heating systems. The scope of the study included determining the parameters of the heat distribution network as a function of an outdoor air temperature within the range of -20°C to + 12°C. The object of analysis was chosen to be the heating system parameters: supply 120°C and return 60°C. It is located on the surface of 160km2, and supplies heat to 240,000 residents. The total length of the district heating network is 170 km. Based on the study, it was found that the most advantageous material that accumulates heat depends on the return temperature in the heating network. For the above analyzed case, the return temperature was in the range of 46°C to 57°C. The analysis showed that the most preferred materials using heat of phase change, have possible applications in heating networks and received a return temperature including salt hydrates, such as MgSO4·7H2O and Na2S2O3·5H2. The introduction of stored heat for the district heating system with the phase change material in the form of salt hydrates, allows the return temperature in the district heating to remain at temperatures compatible with the adopted regulatory table for temperatures outside the standard heating season.

  2. Feasibility study of wireless power transmission systems

    NASA Technical Reports Server (NTRS)

    Robinson, W. J., Jr.

    1968-01-01

    Wireless microwave or laser energy transfers power from a manned earth-orbiting central station to unmanned astronomical substations. More efficient systems are required for the microwave power transmission.

  3. New model of inverting substation for DC traction with regenerative braking system

    NASA Astrophysics Data System (ADS)

    Omar, Abdul Malek Saidina; Samat, Ahmad Asri Abd; Isa, Siti Sarah Mat; Shamsuddin, Sarah Addyani; Jamaludin, Nur Fadhilah; Khyasudeen, Muhammad Farris

    2017-08-01

    This paper presents a power electronic devices application focus on modeling, analysis, and control of switching power converter in the inverting DC substation with regenerative braking system which is used to recycle the surplus regenerative power by feed it back to the main AC grid. The main objective of this research is to improve the switching power electronic converter of the railway inverting substation and optimize the maximum kinetic energy recovery together with minimum power losses from the railway braking system. Assess performance including efficiency and robustness will be evaluated in order to get the best solution for the design configuration. Research methodology included mathematical calculation, simulation, and detail analysis on modeling of switching power converter on inverting substation. The design stage separates to four main areas include rectification mode, regenerative mode, control inverter mode and filtering mode. The simulation result has shown that the regenerative inverter has a capability to accept a maximum recovery power on the regeneration mode. Total energy recovery has increase and power losses have decreases because inverter abilities to transfer the surplus energy back to the main AC supply. An Inverter controller with PWM Generator and PI Voltage Regulator has been designed to control voltage magnitude and frequency of the DC traction system.

  4. Hiding Critical Targets in Smart Grid Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bao, Wei; Li, Qinghua

    With the integration of advanced communication technologies, the power grid is expected to greatly enhance efficiency and reliability of future power systems. However, since most electrical devices in power grid substations are connected via communication networks, cyber security of these communication networks becomes a critical issue. Real-World incidents such as Stuxnet have shown the feasibility of compromising a device in the power grid network to further launch more sophisticated attacks. To deal with security attacks of this spirit, this paper aims to hide critical targets from compromised internal nodes and hence protect them from further attacks launched by those compromisedmore » nodes. In particular, we consider substation networks and propose to add carefully-controlled dummy traffic to a substation network to make critical target nodes indistinguishable from other nodes in network traffic patterns. This paper describes the design and evaluation of such a scheme. Evaluations show that the scheme can effectively protect critical nodes with acceptable communication cost.« less

  5. Ground potential rise characteristics of urban step-down substations fed by power cables - A practical example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sobral, S.T.; Barbosa, J.O.; Numes, J.V.C.

    1988-10-01

    This paper shows some special ground potential rise characteristics of substations fed by power cables. These characteristics were detected during the study of the interconnected ground system of 14 step-down urban substations fed by the 138 kV underground cable network serving the South Zone of Rio de Janeiro city in Brazil. As this type of system is very common in large cities, the subject can be of general interest for the industry. It was verified that when a fault occurs at a ''cable substation'' (a substation fed exclusively by power cables), almost no ground potential effects were detected at themore » faulted substation or at the other ''cable substations'' of the 138 kV network. However, high values of ground potential occurred at the ''transition substations'' (substations in which the power cables are connected to overhead 138 kV transmission lines, with steel groundwires). That ground potential was enough to produce shocks and equipment damage in certain ''transition substations''. It was verified that this problem has no relation with potential transfer. The paper shows also that the utilization of overhead lines with ACSR groundwires on the initial spans closer to the ''transition substation'' would be enough to avoid the problem. Even if the ACSR conductor is used only at the initial section of one of the lines, a reduction of the problem would be obtained. The paper shows also that the utilization of ACSR ground-wires near the ''transition substations'' contributes to reduce the amount of the copper necessary to control step, touch and mess potentials in these substations. Additional mitigation procedures are also examined in the paper.« less

  6. 77 FR 58828 - Northern Indiana Public Service Company; Notice of Petition for Declaratory Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-24

    ... kV transmission line from the Reynolds substation to the Greentown substation and (2) substation upgrades at Reynolds substation, including a 765 kV/345kV transformer, a Multi-Value Project approved under...

  7. Model-centric distribution automation: Capacity, reliability, and efficiency

    DOE PAGES

    Onen, Ahmet; Jung, Jaesung; Dilek, Murat; ...

    2016-02-26

    A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditionalmore » system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.« less

  8. Model-centric distribution automation: Capacity, reliability, and efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onen, Ahmet; Jung, Jaesung; Dilek, Murat

    A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditionalmore » system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.« less

  9. 40 CFR 35.1615 - Substate agreements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Substate agreements. 35.1615 Section 35... STATE AND LOCAL ASSISTANCE Cooperative Agreements for Protecting and Restoring Publicly Owned Freshwater Lakes § 35.1615 Substate agreements. States may make financial assistance available to substate agencies...

  10. 40 CFR 35.1615 - Substate agreements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Substate agreements. 35.1615 Section 35... STATE AND LOCAL ASSISTANCE Cooperative Agreements for Protecting and Restoring Publicly Owned Freshwater Lakes § 35.1615 Substate agreements. States may make financial assistance available to substate agencies...

  11. Fault Current Distribution and Pole Earth Potential Rise (EPR) Under Substation Fault

    NASA Astrophysics Data System (ADS)

    Nnassereddine, M.; Rizk, J.; Hellany, A.; Nagrial, M.

    2013-09-01

    New high-voltage (HV) substations are fed by transmission lines. The position of these lines necessitates earthing design to ensure safety compliance of the system. Conductive structures such as steel or concrete poles are widely used in HV transmission mains. The earth potential rise (EPR) generated by a fault at the substation could result in an unsafe condition. This article discusses EPR based on substation fault. The pole EPR assessment under substation fault is assessed with and without mutual impedance consideration. Split factor determination with and without the mutual impedance of the line is also discussed. Furthermore, a simplified formula to compute the pole grid current under substation fault is included. Also, it includes the introduction of the n factor which determines the number of poles that required earthing assessments under substation fault. A case study is shown.

  12. Using Immersive Virtual Reality for Electrical Substation Training

    ERIC Educational Resources Information Center

    Tanaka, Eduardo H.; Paludo, Juliana A.; Cordeiro, Carlúcio S.; Domingues, Leonardo R.; Gadbem, Edgar V.; Euflausino, Adriana

    2015-01-01

    Usually, distribution electricians are called upon to solve technical problems found in electrical substations. In this project, we apply problem-based learning to a training program for electricians, with the help of a virtual reality environment that simulates a real substation. Using this virtual substation, users may safely practice maneuvers…

  13. Substation alarm multiplexing system (SAMS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ElBadaly, H.; Gaughan, J.; Ward, G.

    1996-03-01

    This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creekmore » substation in the Bronx for the purpose of a three month field evaluation.« less

  14. Probing RNA Native Conformational Ensembles with Structural Constraints.

    PubMed

    Fonseca, Rasmus; van den Bedem, Henry; Bernauer, Julie

    2016-05-01

    Noncoding ribonucleic acids (RNA) play a critical role in a wide variety of cellular processes, ranging from regulating gene expression to post-translational modification and protein synthesis. Their activity is modulated by highly dynamic exchanges between three-dimensional conformational substates, which are difficult to characterize experimentally and computationally. Here, we present an innovative, entirely kinematic computational procedure to efficiently explore the native ensemble of RNA molecules. Our procedure projects degrees of freedom onto a subspace of conformation space defined by distance constraints in the tertiary structure. The dimensionality reduction enables efficient exploration of conformational space. We show that the conformational distributions obtained with our method broadly sample the conformational landscape observed in NMR experiments. Compared to normal mode analysis-based exploration, our procedure diffuses faster through the experimental ensemble while also accessing conformational substates to greater precision. Our results suggest that conformational sampling with a highly reduced but fully atomistic representation of noncoding RNA expresses key features of their dynamic nature.

  15. Discovering Conformational Sub-States Relevant to Protein Function

    PubMed Central

    Ramanathan, Arvind; Savol, Andrej J.; Langmead, Christopher J.; Agarwal, Pratul K.; Chennubhotla, Chakra S.

    2011-01-01

    Background Internal motions enable proteins to explore a range of conformations, even in the vicinity of native state. The role of conformational fluctuations in the designated function of a protein is widely debated. Emerging evidence suggests that sub-groups within the range of conformations (or sub-states) contain properties that may be functionally relevant. However, low populations in these sub-states and the transient nature of conformational transitions between these sub-states present significant challenges for their identification and characterization. Methods and Findings To overcome these challenges we have developed a new computational technique, quasi-anharmonic analysis (QAA). QAA utilizes higher-order statistics of protein motions to identify sub-states in the conformational landscape. Further, the focus on anharmonicity allows identification of conformational fluctuations that enable transitions between sub-states. QAA applied to equilibrium simulations of human ubiquitin and T4 lysozyme reveals functionally relevant sub-states and protein motions involved in molecular recognition. In combination with a reaction pathway sampling method, QAA characterizes conformational sub-states associated with cis/trans peptidyl-prolyl isomerization catalyzed by the enzyme cyclophilin A. In these three proteins, QAA allows identification of conformational sub-states, with critical structural and dynamical features relevant to protein function. Conclusions Overall, QAA provides a novel framework to intuitively understand the biophysical basis of conformational diversity and its relevance to protein function. PMID:21297978

  16. Deep learning based state recognition of substation switches

    NASA Astrophysics Data System (ADS)

    Wang, Jin

    2018-06-01

    Different from the traditional method which recognize the state of substation switches based on the running rules of electrical power system, this work proposes a novel convolutional neuron network-based state recognition approach of substation switches. Inspired by the theory of transfer learning, we first establish a convolutional neuron network model trained on the large-scale image set ILSVRC2012, then the restricted Boltzmann machine is employed to replace the full connected layer of the convolutional neuron network and trained on our small image dataset of 110kV substation switches to get a stronger model. Experiments conducted on our image dataset of 110kV substation switches show that, the proposed approach can be applicable to the substation to reduce the running cost and implement the real unattended operation.

  17. Project FOOTPRINT: Substation modeling and simulations for E1 pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Scott D.; Larson, D. J.; Kirkendall, B. A.

    This report includes a presentation with an: Introduction to CW coupling; Introduction to single-pulse coupling; Description of E1 waveforms; Structures in a substation yard --articulated (as part of the substation's defined electrical functionality)--unarticulated (not as part of the substation's defined electrical functionality); Coupling --electrical coupling (capacitive coupling) --magnetic coupling (inductive coupling); Connectivity to long-line transmission lines; Control infrastructure; Summary; and References.

  18. View of EPA Farm power substation, facing westsouthwest Nevada ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of EPA Farm power substation, facing west-southwest - Nevada Test Site, Environmental Protection Agency Farm, Power Substation, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  19. Resilient Core Networks for Energy Distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuntze, Nicolai; Rudolph, Carsten; Leivesley, Sally

    2014-07-28

    Abstract—Substations and their control are crucial for the availability of electricity in today’s energy distribution. Ad- vanced energy grids with Distributed Energy Resources require higher complexity in substations, distributed functionality and communication between devices inside substations and between substations. Also, substations include more and more intelligent devices and ICT based systems. All these devices are connected to other systems by different types of communication links or are situated in uncontrolled environments. Therefore, the risk of ICT based attacks on energy grids is growing. Consequently, security measures to counter these risks need to be an intrinsic part of energy grids. Thismore » paper introduces the concept of a Resilient Core Network to interconnected substations. This core network provides essen- tial security features, enables fast detection of attacks and allows for a distributed and autonomous mitigation of ICT based risks.« less

  20. Inverse problem and variation method to optimize cascade heat exchange network in central heating system

    NASA Astrophysics Data System (ADS)

    Zhang, Yin; Wei, Zhiyuan; Zhang, Yinping; Wang, Xin

    2017-12-01

    Urban heating in northern China accounts for 40% of total building energy usage. In central heating systems, heat is often transferred from heat source to users by the heat network where several heat exchangers are installed at heat source, substations and terminals respectively. For given overall heating capacity and heat source temperature, increasing the terminal fluid temperature is an effective way to improve the thermal performance of such cascade heat exchange network for energy saving. In this paper, the mathematical optimization model of the cascade heat exchange network with three-stage heat exchangers in series is established. Aim at maximizing the cold fluid temperature for given hot fluid temperature and overall heating capacity, the optimal heat exchange area distribution and the medium fluids' flow rates are determined through inverse problem and variation method. The preliminary results show that the heat exchange areas should be distributed equally for each heat exchanger. It also indicates that in order to improve the thermal performance of the whole system, more heat exchange areas should be allocated to the heat exchanger where flow rate difference between two fluids is relatively small. This work is important for guiding the optimization design of practical cascade heating systems.

  1. Efficient catalysis of Nazarov cyclization using a cationic iridium complex possessing adjacent labile coordination sites.

    PubMed

    Janka, Mesfin; He, Wei; Frontier, Alison J; Eisenberg, Richard

    2004-06-09

    The dicationic Ir(III) complex [IrMe(CO)(dppe)(DIB)](BARF)2 having adjacent labile sites has been found to be a very effective catalyst for promoting the Nazarov cyclization of aryl vinyl and divinyl ketones. Spectroscopic evidence for a substate-catalyst complex before cyclization is presented. The efficiency of the cyclization is attributed to the electrophilicity of the Ir(III) complex and substrate activation via chelation.

  2. Workers' exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations.

    PubMed

    Korpinen, Leena; Pääkkönen, Rauno

    2018-02-26

    The objective of the study was to investigate occupational exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations. The aim was also to compare the results to Directive 2013/35/EU. At 16 substations, 255 electric field measurements were performed. The highest mean value of the electric fields was 9.6 kV⋅m -1 . At 63% of substations the maximum values were over 10.0 kV⋅m -1 , and at 31% of the substations the 75th percentiles were over 10.0 kV⋅m -1 , which is the low action level (AL) according to Directive 2013/35/EU. All measured values were below the high AL (20.0 kV⋅m -1 ). In the future, it is important to take into account that the measurements were only taken at Finnish 110-kV substations; therefore, it is not possible to generalize these results to other countries and different types of substations.

  3. AUTOMATED UTILITY SERVICE AREA ASSESSMENT UNDER EMERGENCY CONDITIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G. TOOLE; S. LINGER

    2001-01-01

    All electric utilities serve power to their customers through a variety of functional levels, notably substations. The majority of these components consist of distribution substations operating at lower voltages while a small fraction are transmission substations. There is an associated geographical area that encompasses customers who are served, defined as the service area. Analysis of substation service areas is greatly complicated by several factors: distribution networks are often highly interconnected which allows a multitude of possible switching operations; also, utilities dynamically alter the network topology in order to respond to emergency events. As a result, the service area for amore » substation can change radically. A utility will generally attempt to minimize the number of customers outaged by switching effected loads to alternate substations. In this manner, all or a portion of a disabled substation's load may be served by one or more adjacent substations. This paper describes a suite of analytical tools developed at Los Alamos National Laboratory (LANL), which address the problem of determining how a utility might respond to such emergency events. The estimated outage areas derived using the tools are overlaid onto other geographical and electrical layers in a geographic information system (GIS) software application. The effects of a power outage on a population, other infrastructures, or other physical features, can be inferred by the proximity of these features to the estimated outage area.« less

  4. Structural assessment of highway "N" power substation under earthquake loads.

    DOT National Transportation Integrated Search

    2009-10-01

    In this study, the Highway N Substation was analyzed with a finite element model (FEM) for its vulnerability. The rigid bus and electric switch components were characterized with full scale shake table tests. Each component of the substation wa...

  5. Substation Reactive Power Regulation Strategy

    NASA Astrophysics Data System (ADS)

    Zhang, Junfeng; Zhang, Chunwang; Ma, Daqing

    2018-01-01

    With the increasing requirements on the power supply quality and reliability of distribution network, voltage and reactive power regulation of substations has become one of the indispensable ways to ensure voltage quality and reactive power balance and to improve the economy and reliability of distribution network. Therefore, it is a general concern of the current power workers and operators that what kind of flexible and effective control method should be used to adjust the on-load tap-changer (OLTC) transformer and shunt compensation capacitor in a substation to achieve reactive power balance in situ, improve voltage pass rate, increase power factor and reduce active power loss. In this paper, based on the traditional nine-zone diagram and combining with the characteristics of substation, a fuzzy variable-center nine-zone diagram control method is proposed and used to make a comprehensive regulation of substation voltage and reactive power. Through the calculation and simulation of the example, this method is proved to have satisfactorily reconciled the contradiction between reactive power and voltage in real-time control and achieved the basic goal of real-time control of the substation, providing a reference value to the practical application of the substation real-time control method.

  6. 17. Photocopy of photograph showing excavation of South Bank Substation ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Photocopy of photograph showing excavation of South Bank Substation site, 15 May 1939 (from the BPA Photo Archives, Portland, Oregon, Negative No. 345), LOOKING WEST - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  7. 20 CFR 631.82 - Substate allocation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Substate allocation. 631.82 Section 631.82 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR PROGRAMS UNDER TITLE III OF THE JOB TRAINING PARTNERSHIP ACT Disaster Relief Employment Assistance § 631.82 Substate allocation...

  8. Global motions exhibited by proteins in micro- to milliseconds simulations concur with anisotropic network model predictions

    NASA Astrophysics Data System (ADS)

    Gur, M.; Zomot, E.; Bahar, I.

    2013-09-01

    The Anton supercomputing technology recently developed for efficient molecular dynamics simulations permits us to examine micro- to milli-second events at full atomic resolution for proteins in explicit water and lipid bilayer. It also permits us to investigate to what extent the collective motions predicted by network models (that have found broad use in molecular biophysics) agree with those exhibited by full-atomic long simulations. The present study focuses on Anton trajectories generated for two systems: the bovine pancreatic trypsin inhibitor, and an archaeal aspartate transporter, GltPh. The former, a thoroughly studied system, helps benchmark the method of comparative analysis, and the latter provides new insights into the mechanism of function of glutamate transporters. The principal modes of motion derived from both simulations closely overlap with those predicted for each system by the anisotropic network model (ANM). Notably, the ANM modes define the collective mechanisms, or the pathways on conformational energy landscape, that underlie the passage between the crystal structure and substates visited in simulations. In particular, the lowest frequency ANM modes facilitate the conversion between the most probable substates, lending support to the view that easy access to functional substates is a robust determinant of evolutionarily selected native contact topology.

  9. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  10. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  11. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  12. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  13. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  14. Research on Vibration Test in Urban Indoor Substation

    NASA Astrophysics Data System (ADS)

    Ma, Yuchao; Mo, Juan; Xu, Jin; Fan, Baozhen

    2018-01-01

    The problem of vibration and noise of urban indoor substations has becoming more and more socially concerned.The urban indoor substation of 110kV and its conjoined buildings were taken as the research object and the vibration tests of the transformer and each floor slab were respectively carried out.The sound vibration characteristics and sound transmission rules of the urban indoor substation were obtained through the time-frequency analysis and coherence analysis of the test data. The vibration spectrum of transformer body was mainly 100Hz together with its multiplying factors and the vibration characteristics of the floor slab were basically the same as those of the transformer body. it is crucial to control the vibration and noise transmission in the equipment floor of the urban indoor substation.

  15. Protein Conformational Populations and Functionally Relevant Sub-states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, Pratul K; Burger, Virginia; Savol, Andrej

    2013-01-01

    Functioning proteins do not remain fixed in a unique structure, but instead they sample a range of conformations facilitated by motions within the protein. Even in the native state, a protein exists as a collection of interconverting conformations driven by thermodynamic fluctuations. Motions on the fast time scale allow a protein to sample conformations in the nearby area of its conformational landscape, while motions on slower time scales give it access to conformations in distal areas of the landscape. Emerging evidence indicates that protein landscapes contain conformational substates with dynamic and structural features that support the designated function of themore » protein. Nuclear magnetic resonance (NMR) experiments provide information about conformational ensembles of proteins. X-ray crystallography allows researchers to identify the most populated states along the landscape, and computational simulations give atom-level information about the conformational substates of different proteins. This ability to characterize and obtain quantitative information about the conformational substates and the populations of proteins within them is allowing researchers to better understand the relationship between protein structure and dynamics and the mechanisms of protein function. In this Account, we discuss recent developments and challenges in the characterization of functionally relevant conformational populations and substates of proteins. In some enzymes, the sampling of functionally relevant conformational substates is connected to promoting the overall mechanism of catalysis. For example, the conformational landscape of the enzyme dihydrofolate reductase has multiple substates, which facilitate the binding and the release of the cofactor and substrate and catalyze the hydride transfer. For the enzyme cyclophilin A, computational simulations reveal that the long time scale conformational fluctuations enable the enzyme to access conformational substates that allow it to attain the transition state, therefore promoting the reaction mechanism. In the long term, this emerging view of proteins with conformational substates has broad implications for improving our understanding of enzymes, enzyme engineering, and better drug design. Researchers have already used photoactivation to modulate protein conformations as a strategy to develop a hypercatalytic enzyme. In addition, the alteration of the conformational substates through binding of ligands at locations other than the active site provides the basis for the design of new medicines through allosteric modulation.« less

  16. 20. Photocopy of photograph showing the completed South Bank Substation, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Photocopy of photograph showing the completed South Bank Substation, 4 November 1939 (from the BPA Photo Archives, Negative No. 6556), LOOKING NORTHWEST WITH THE BONNEVILLE DAM POWERHOUSE AND TRANSMISSION TOWERS IN BACKGROUND - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  17. Research on the Best Root Span of 500kV Substation Frame Based on Finite Element

    NASA Astrophysics Data System (ADS)

    Chen, Hao; Fang, Qing; Chen, Haoyuan

    2018-01-01

    A-shaped and steel tube structures have been widely applied when designing 500kV substation frame in China. While, compared with steel tube, angle steels have an advantage of easy-transporting, especially in oversea projects. However, researches on substation frame with angle steel were not enough. In order to find out the best root span of 500kV substation frame under similar engineering conditions, using the overseas project substation frame as an example, the substation frames with different root span have been detailed calculated, to find the best root span according to the cost of it. When the height of column is about 30m, the root suggestion value is 6.1m×3.1m. And then, the buckling analysis of the overall structure has been carried out by ANSYS, to find out that the weak part of the structure is in the middle of it. The structural adjustment is carried out for the weak part, including adjusting the web members and the chord members, to obtain a higher bearing capacity of the structure.

  18. Hydrology Analysis and Modelling for Klang River Basin Flood Hazard Map

    NASA Astrophysics Data System (ADS)

    Sidek, L. M.; Rostam, N. E.; Hidayah, B.; Roseli, ZA; Majid, W. H. A. W. A.; Zahari, N. Z.; Salleh, S. H. M.; Ahmad, R. D. R.; Ahmad, M. N.

    2016-03-01

    Flooding, a common environmental hazard worldwide has in recent times, increased as a result of climate change and urbanization with the effects felt more in developing countries. As a result, the explosive of flooding to Tenaga Nasional Berhad (TNB) substation is increased rapidly due to existing substations are located in flood prone area. By understanding the impact of flood to their substation, TNB has provided the non-structure mitigation with the integration of Flood Hazard Map with their substation. Hydrology analysis is the important part in providing runoff as the input for the hydraulic part.

  19. 76 FR 45609 - Notice of Availability of the Draft Environmental Impact Statement for the Gateway West 230/500...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... Johnston Power Plant at Glenrock, Wyoming, to the proposed Hemingway Substation near Melba, Idaho. The... Johnston Power Plant at Glenrock, Wyoming, and the planned Aeolus Substation near Hanna, Wyoming. Segment... Anticline Substation near the Jim Bridger Power Plant, located approximately 30 miles east of Rock Springs...

  20. Conformational switching between protein substates studied with 2D IR vibrational echo spectroscopy and molecular dynamics simulations.

    PubMed

    Bagchi, Sayan; Thorpe, Dayton G; Thorpe, Ian F; Voth, Gregory A; Fayer, M D

    2010-12-30

    Myoglobin is an important protein for the study of structure and dynamics. Three conformational substates have been identified for the carbonmonoxy form of myoglobin (MbCO). These are manifested as distinct peaks in the IR absorption spectrum of the CO stretching mode. Ultrafast 2D IR vibrational echo chemical exchange experiments are used to observed switching between two of these substates, A(1) and A(3), on a time scale of <100 ps for two mutants of wild-type Mb. The two mutants are a single mutation of Mb, L29I, and a double mutation, T67R/S92D. Molecular dynamics (MD) simulations are used to model the structural differences between the substates of the two MbCO mutants. The MD simulations are also employed to examine the substate switching in the two mutants as a test of the ability of MD simulations to predict protein dynamics correctly for a system in which there is a well-defined transition over a significant potential barrier between two substates. For one mutant, L29I, the simulations show that translation of the His64 backbone may differentiate the two substates. The simulations accurately reproduce the experimentally observed interconversion time for the L29I mutant. However, MD simulations exploring the same His64 backbone coordinate fail to display substate interconversion for the other mutant, T67R/S92D, thus pointing to the likely complexity of the underlying protein interactions. We anticipate that understanding conformational dynamics in MbCO via ultrafast 2D IR vibrational echo chemical exchange experiments can help to elucidate fast conformational switching processes in other proteins.

  1. 50 kWp Photovoltaic Concentrator Application Experiment, Phase I. Final report, 1 June 1978-28 February 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maget, H.J.R.

    1979-06-15

    This program consists of a design study and component development for an experimental 50-kWp photovoltaic concentrator system to supply power to the San Ramon substation of the Pacific Gas and Electric Company. The photovoltaic system is optimized to produce peaking power to relieve the air conditioning load on the PG and E system during summer afternoons; and would therefore displace oil-fired power generation capacity. No electrical storage is required. The experiment would use GaAs concentrator cells with point-focus fresnel lenses operating at 400X, in independent tracking arrays of 440 cells each, generating 3.8 kWp. Fourteen arrays, each 9 feet bymore » 33 feet, are connected electrically in series to generate the 50 kWp. The high conversion efficiency possible with GaAs concentrator cells results in a projected annual average system efficiency (AC electric power output to sunlight input) of better than 15%. The capability of GaAs cells for high temperature operation made possible the design of a total energy option, whereby thermal power from selected arrays could be used to heat and cool the control center for the installation. System design and analysis, fabrication and installation, environmental assessment, and cost projections are described in detail. (WHK)« less

  2. Direct observation of fast protein conformational switching.

    PubMed

    Ishikawa, Haruto; Kwak, Kyungwon; Chung, Jean K; Kim, Seongheun; Fayer, Michael D

    2008-06-24

    Folded proteins can exist in multiple conformational substates. Each substate reflects a local minimum on the free-energy landscape with a distinct structure. By using ultrafast 2D-IR vibrational echo chemical-exchange spectroscopy, conformational switching between two well defined substates of a myoglobin mutant is observed on the approximately 50-ps time scale. The conformational dynamics are directly measured through the growth of cross peaks in the 2D-IR spectra of CO bound to the heme active site. The conformational switching involves motion of the distal histidine/E helix that changes the location of the imidazole side group of the histidine. The exchange between substates changes the frequency of the CO, which is detected by the time dependence of the 2D-IR vibrational echo spectrum. These results demonstrate that interconversion between protein conformational substates can occur on very fast time scales. The implications for larger structural changes that occur on much longer time scales are discussed.

  3. Analysis of the 35 KV substation secondary system

    NASA Astrophysics Data System (ADS)

    Zhao, Yong; Jiang, Jianguo; Jiang, Chunlei; Ren, Shuang; Liu, Songbin

    2017-04-01

    This paper analyzes the status of the two system of some 35KV users' substation in Daqing oil field, the deficiencies of the two system of the existing 35KV substation are found out. And put forward the opinion of acceptance in the future work. I hope it can able to work in the future on the protection of professional help.

  4. Shielding of substations against direct lightning strokes by shield wires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chowdhuri, P.

    1994-01-01

    A new analysis for shielding outdoor substations against direct lightning strokes by shield wires is proposed. The basic assumption of this proposed method is that any lightning stroke which penetrates the shields will cause damage. The second assumption is that a certain level of risk of failure must be accepted, such as one or two failures per 100 years. The proposed method, using electrogeometric model, was applied to design shield wires for two outdoor substations: (1) 161-kV/69-kV station, and (2) 500-kV/161-kV station. The results of the proposed method were also compared with the shielding data of two other substations.

  5. IET. Exclusion guard house (TAN621) and unit substation (TAN622). Elevations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    IET. Exclusion guard house (TAN-621) and unit substation (TAN-622). Elevations and floor plan. Also show concrete pad for substation. Ralph M. Parsons 902-4-ANP-621-622-A&S 411. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0621-60-693-106968 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  6. Simulation study on the lightning overvoltage invasion control transformer intelligent substation

    NASA Astrophysics Data System (ADS)

    Xi, Chuyan; Hao, Jie; Zhang, Ying

    2018-04-01

    By simulating lightning on substation line of one intelligent substation, research the influence of different lightning points on lightning invasion wave overvoltage, and the necessity of arrester for the main transformer. The results show, in a certain lightning protection measures, the installation of arrester nearby the main transformer can effectively reduce the overvoltage value of bus and the main transformer [1].

  7. An expansion plan for the 60 Hz power distribution system at KSC: LC-39 substations load allocation plan

    NASA Technical Reports Server (NTRS)

    Kalu, Alex

    1990-01-01

    The increasing load density in the LC-39 area of Kennedy Space Center (KSC) can be met by either modifying the existing substation and increasing its capacity or by planning an additional new substation. Evidence that the later approach is more economical, enhances the system reliability, and would produce more satisfactory performance indices is provided. Network theory is the basis for the optimal location determination of the proposed substation. A load reallocation plan which minimizes investment cost and power losses and meets other desirable system features is drafted. The report should be useful to the system designer and can be a useful guideline for future facility planners.

  8. Conformational Sub-states and Populations in Enzyme Catalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, Pratul K; Doucet, Nicholas; Chennubholta, C

    reactants in the active site, chemical turnover, and release of products. In addition to formation of crucial structural interactions between enzyme and substrate(s), coordinated motions within the enzyme substrate complex allow reaction to proceed at a much faster rate, compared to the reaction in solution and in the absence of enzyme. An increasing number of enzyme systems show the presence of conserved protein motions that are important for function. A wide variety of motions are naturally sampled (over femtosecond to millisecond time-scales) as the enzyme complex moves along the energetic landscape, driven by temperature and dynamical events from the surroundingmore » environment. Areas of low energy along the landscape form conformational sub-states, which show higher conformational populations than surrounding areas. A small number of these protein conformational sub-states contain functionally important structural and dynamical features, which assist the enzyme mechanism along the catalytic cycle. Identification and characterization of these higher-energy (also called excited) sub-states and the associated populations are challenging, as these sub-states are very short-lived and therefore rarely populated. Specialized techniques based on computer simulations, theoretical modeling, and nuclear magnetic resonance have been developed for quantitative characterization of these sub-states and populations. This chapter discusses these techniques and provides examples of their applications to enzyme systems.« less

  9. [Offshore substation workers' exposure to harmful factors - Actions minimizing risk of hazards].

    PubMed

    Piotrowski, Paweł Janusz; Robak, Sylwester; Polewaczyk, Mateusz Maksymilian; Raczkowski, Robert

    2016-01-01

    The current development of electric power industry in Poland, especially in the field of renewable energy sources, including wind power, brings about the need to introduce legislation on new work environment. The development of occupational safety and health (OSH) regulations that must be met by new workplaces, such as offshore substations becomes necessary in view of the construction of modern offshore wind power plants - offshore wind farms. Staying on offshore substation is associated with an increased exposure to harmful health factors: physical, chemical, biological and psychophysical. The main sources of health risks on offshore substations are: temperature, electromagnetic field, noise from operating wind turbines, direct and alternating current, chemicals, Legionella bacteria and social isolation of people. The aim of this article is to draw attention to the problem of offshore substation workers' exposure to harmful factors and to present methods of preventing and reducing the risk-related adverse health effects. In this paper, there are identified and described risks occurring on offshore substations (fire, explosion, lightning, accidents at work). Some examples of the means and the methods for reducing the negative impact of exposure on the human health are presented and discussed. The article also highlights the need to develop appropriate laws and health and safety regulations concerning the new working environment at the offshore substations. The review of researches and international standards shows that some of them can be introduced into the Polish labor market. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  10. Touch and step potential analysis at 23.9kV to 4.16kV & 13.8kV to 4.16kV distribution substations with pad-mounted transformers, floating grounds, and other exposed ungrounded metal bodies using WinIGS

    NASA Astrophysics Data System (ADS)

    Guzman, David G.

    An electrical substation is composed of various subsystems that allow for the effective and safe operation of the power grid. One of the subsystems integrating a conventional substation is defined as the ground grid system. This system allows for the effective operation of the power grid and all the electrical equipment connected to it by providing a ground potential reference, commonly known as the system ground. In addition, the ground grid system provides safety to the workers and the public transiting inside or living nearby a substation by reducing the step and touch potential (or voltage) levels present during a system fault. In today's utility industry practices there is an increasing trend for using pad-mounted electrical equipment for substation applications in an effort to construct new or upgrade existing electrical facilities inside limited property spaces. This thesis work presents an analysis for the effects of touch and step voltages at existing distribution substations where 23.9kV to 4.16kV & 13.8kV to 4.16kV pad-mounted transformers and other pad-mounted switchgear was installed to replace the traditional station class equipment. Moreover, this study will expose modeling techniques employed to define and determine the effects of floating grounds and other exposed metal bodies inside or surrounding these substations using WinIGS; this is in an effort to determine any risks of electric shock associated with this type of installations. The results presented in this work are intended to verify the requirements for the ground grid analysis and design for 4.16kV distribution substations with pad-mounted equipment in order to prevent dangerous step and touch voltage levels appearing at these sites during system faults; and ultimately prevent exposing individuals to the risk of an electric shock.

  11. Design of a laser navigation system for the inspection robot used in substation

    NASA Astrophysics Data System (ADS)

    Zhu, Jing; Sun, Yanhe; Sun, Deli

    2017-01-01

    Aimed at the deficiency of the magnetic guide and RFID parking system used by substation inspection robot now, a laser navigation system is designed, and the system structure, the method of map building and positioning are all introduced. The system performance is tested in a 500kV substation, and the result show that the repetitive precision of navigation system is precise enough to help the robot fulfill inspection tasks.

  12. An improved method for predicting the lightning performance of high and extra-high-voltage substation shielding

    NASA Astrophysics Data System (ADS)

    Vinh, T.

    1980-08-01

    There is a need for better and more effective lightning protection for transmission and switching substations. In the past, a number of empirical methods were utilized to design systems to protect substations and transmission lines from direct lightning strokes. The need exists for convenient analytical lightning models adequate for engineering usage. In this study, analytical lightning models were developed along with a method for improved analysis of the physical properties of lightning through their use. This method of analysis is based upon the most recent statistical field data. The result is an improved method for predicting the occurrence of sheilding failure and for designing more effective protection for high and extra high voltage substations from direct strokes.

  13. The Millimeter- and Submillimeter-Wave Spectrum of Gauche-Ethyl Alcohol

    NASA Technical Reports Server (NTRS)

    Pearson, J. C.; Sastry, K. V. L. N.; Herbst, Eric; DeLucia, Frank C.

    1996-01-01

    We report an investigation of the rotational-torsional spectrum of the gauche rotational isomers of ethyl alcohol in the 51-505 GHz frequency region. Over a thousand transitions between rotational levels in the gauche substates of the ground OH torsional state have been measured and assigned. These transitions involve rotational quantum numbers J and K(sub a) up to 30 and 15, respectively, and are of two types: alpha-type transitions between levels in either the gauche+ or the gauche-substate, and c-type transitions between rotational levels in the different substates. The majority of these transitions have been fit satisfactorily using a two-state Hamiltonian based on the Fixed Framework Axis Method (FFAM). The rotation, distortion, and interaction constants have been determined along with the energy difference between the two gauche substates. The derived constants can be used to predict many more transitions accurately for astronomical purposes. The J and K(sub a) region where the two-state analysis can be used has been determined. The basis for a three-state analysis including the trans substate is presented and the applicability of the FFAM approach is discussed.

  14. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.957 Construction in energized substations. (a) Work near energized equipment facilities. (1...

  15. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.957 Construction in energized substations. (a) Work near energized equipment facilities. (1...

  16. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.957 Construction in energized substations. (a) Work near energized equipment facilities. (1...

  17. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-101) Spokane Region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosales, Michael A.

    2002-09-13

    Vegetation Management for Substations and Non-Electric Facilities. BPA proposes to manage vegetation inside and around electrical substations and associated facilities. Vegetation management within the substation shall include the bare ground management of all graveled areas. These areas shall primarily be maintained with the use of herbicides. The management of vegetation outside the substation and associated facilities shall include: 1) bare ground management of perimeter roads and parking areas; 2) mechanical and/or spot herbicidal control of some broadleaves and noxious weeds; 3) mowing, fertilizing, and broadleaf control of landscaped lawn areas; 4) weed control in ornamental shrub areas; and 5) areasmore » requiring only mechanical control to manage unwanted/danger trees, grasses, and shrubs.« less

  18. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-64)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutchinson, Ken

    2002-04-26

    Vegetation Management for Substations and Non-Electric Facilities in the Walla Walla Region. BPA proposes to manage vegetation inside and around electrical substations and associated facilities. Vegetation management within the substation shall include the bare ground management of all graveled areas. These areas shall primarily be maintained with the use of herbicides. The management of vegetation outside the substation and associated facilities shall include: 1) bare ground management of perimeter roads and parking areas; 2) mechanical and/or spot herbicidal control of some broadleaves and noxious weeds; 3) mowing, fertilizing, and broadleaf control of landscaped lawn areas; 4) weed control in ornamentalmore » shrub areas; and 4) areas requiring only mechanical control to manage unwanted/danger trees, grasses, and shrubs.« less

  19. IEC 61850: Technology Standards and Cyber-Security Threats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youssef, Tarek A; El Hariri, mohamed; Bugay, Nicole

    Substations constitute a fundamental part in providing reliable electricity to consumers. For a substation to maintain electricity reliability and its own real-time operability, communication between its components is inevitable. Before the emergence of IEC 61850, inter-substation communication was established via expensive copper wires with limited capabilities. IEC 61850 is the standard set by the International Electrotechnical Commission (IEC) Technical Committee Number 57 Working Group 10 and IEEE for Ethernet (IEEE 802.3)-based communication in electrical substations. Like many power grid systems standards, IEC 61850 was set without extensive consideration for critical security measures. This paper discusses IEC 61850 technology standards andmore » applications thoroughly and points out major security vulnerabilities it introduces in the context of current cyber-physical smart grid systems.« less

  20. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 56.4130 Electric substations...

  1. 20. Zoo Substation. Philadelphia, Philadelphia Co., PA. Sec. 1101, MP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Zoo Substation. Philadelphia, Philadelphia Co., PA. Sec. 1101, MP 87.25. - Northeast Railroad Corridor, Amtrak route between Delaware-Pennsylvania & Pennsylvania-New Jersey state lines, Philadelphia, Philadelphia County, PA

  2. Energy storage and alternatives to improve train voltage on a mass transit system

    NASA Astrophysics Data System (ADS)

    Gordon, S. P.; Rorke, W. S.

    1995-04-01

    The wide separation of substations in the Bay Area Rapid Transit system's transbay tunnel contributes to voltage sag when power demand is high. In the future, expansions to the system will exacerbate this problem by increasing traffic density. Typically, this situation is remedied through the installation of additional substations to increase the system's power capacity. We have evaluated the efficacy of several alternatives to this approach - specifically, installation of an 8 megajoule energy storage system, modification of the existing substations, or reduction of the resistance of the running rails or the third rail. To support this analysis, we have developed a simple model of the traction power system in the tunnel. We have concluded that the storage system does not have sufficient capacity to deal with the expected voltage sags; in this application, the alternatives present more effective solutions. We have also investigated the potential impact of these system upgrades on expected future capital outlays by BART for traction power infrastructure additions. We have found that rail or substation upgrades may reduce the need for additional substations. These upgrades may also be effective on other parts of the BART system and on other traction power systems.

  3. 46. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF INFLOW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF INFLOW CONTROLLER WITH ORIGINAL CAPACITOR BANK. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  4. 125. TRANSFORMER SUBSTATIONS ON NORTH SIDE OF TRANSFORMER ROOM (112), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    125. TRANSFORMER SUBSTATIONS ON NORTH SIDE OF TRANSFORMER ROOM (112), FACING SOUTH - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  5. On issue of reconstruction at central distribution substation by example of one of plants of Chelyabinsk region

    NASA Astrophysics Data System (ADS)

    Brylina, O. G.; Semenova, K. D.; Shashkin, V. YU

    2018-03-01

    The article considers the issues of increasing the reliability and economy of the distribution substation. The result is found due to the reconstruction of the central distribution substation and one of the plants of Chelyabinsk region. The reasons for the reconstruction are explained. A comparison of oil and vacuum circuit breakers is made. The advantages of vacuum circuit breakers are shown. Alternative replacement of cables is offered. The basic technical characteristics of the cable brands are shown. The results of reconstruction are proved.

  6. 170. Credit SHS. Northern California Power Company substation, Bully Hill ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    170. Credit SHS. Northern California Power Company substation, Bully Hill Mine area. Note lack of vegetation, caused by nearby copper smelting works. - Battle Creek Hydroelectric System, Battle Creek & Tributaries, Red Bluff, Tehama County, CA

  7. NY32649 ELECTRICAL SUBSTATION (BUILDING 2675) AND EDUCATION CENTER (BUILDING 2670) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NY-326-49 ELECTRICAL SUBSTATION (BUILDING 2675) AND EDUCATION CENTER (BUILDING 2670) AT NORTH END OF ARIZONA AVENUE. VIEW TO NORTHEAST. - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermeston, Mark W.

    BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Covington District of the Snohomish Region. BPA proposes to manage vegetation inside and around electrical substations and associated facilities. Vegetation management within the substations will include bareground management by herbicides of all areas within the fenced perimeter of the facility including a bareground zone of up to 3 meters (10 feet) outside of the fenced area. The management of vegetation outside the substation and associated facilities willmore » include: 1) bare ground management of perimeter roads and parking areas; 2) control of noxious weeds throughout property boundaries; 3) mowing, fertilizing, and weed control of landscaped lawn and mulched areas; 4) weed control in ornamental shrub areas; and 5) areas requiring only mechanical control to manage unwanted/danger trees, grasses, and shrubs.« less

  9. 78 FR 9687 - Prineville Energy Storage, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-11

    ... PDCI to the Ponderosa substation, or (ii) the Bonneville Power Administration (BPA) existing transmission line corridor and then running parallel to the BPA line to the Ponderosa substation; and (9...

  10. POWERHOUSES, SOUTH ELEVATIONS SHOWING OIL HOUSE, FILER SUBSTATION, AND DRAFT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    POWERHOUSES, SOUTH ELEVATIONS SHOWING OIL HOUSE, FILER SUBSTATION, AND DRAFT TUBE OUTLET (TAILRACE), VERTICAL VIEW; FACING WEST - Shoshone Falls Hydroelectric Project, Canyon Road, North Bank of Snake River below Shoshone Falls, Tipperary Corner, Jerome County, ID

  11. Elliptic Curve Cryptography-Based Authentication with Identity Protection for Smart Grids

    PubMed Central

    Zhang, Liping; Tang, Shanyu; Luo, He

    2016-01-01

    In a smart grid, the power service provider enables the expected power generation amount to be measured according to current power consumption, thus stabilizing the power system. However, the data transmitted over smart grids are not protected, and then suffer from several types of security threats and attacks. Thus, a robust and efficient authentication protocol should be provided to strength the security of smart grid networks. As the Supervisory Control and Data Acquisition system provides the security protection between the control center and substations in most smart grid environments, we focus on how to secure the communications between the substations and smart appliances. Existing security approaches fail to address the performance-security balance. In this study, we suggest a mitigation authentication protocol based on Elliptic Curve Cryptography with privacy protection by using a tamper-resistant device at the smart appliance side to achieve a delicate balance between performance and security of smart grids. The proposed protocol provides some attractive features such as identity protection, mutual authentication and key agreement. Finally, we demonstrate the completeness of the proposed protocol using the Gong-Needham- Yahalom logic. PMID:27007951

  12. Elliptic Curve Cryptography-Based Authentication with Identity Protection for Smart Grids.

    PubMed

    Zhang, Liping; Tang, Shanyu; Luo, He

    2016-01-01

    In a smart grid, the power service provider enables the expected power generation amount to be measured according to current power consumption, thus stabilizing the power system. However, the data transmitted over smart grids are not protected, and then suffer from several types of security threats and attacks. Thus, a robust and efficient authentication protocol should be provided to strength the security of smart grid networks. As the Supervisory Control and Data Acquisition system provides the security protection between the control center and substations in most smart grid environments, we focus on how to secure the communications between the substations and smart appliances. Existing security approaches fail to address the performance-security balance. In this study, we suggest a mitigation authentication protocol based on Elliptic Curve Cryptography with privacy protection by using a tamper-resistant device at the smart appliance side to achieve a delicate balance between performance and security of smart grids. The proposed protocol provides some attractive features such as identity protection, mutual authentication and key agreement. Finally, we demonstrate the completeness of the proposed protocol using the Gong-Needham-Yahalom logic.

  13. 8. VIEW EASTNORTHEAST OF TRANSFORMER BAYS AND SUBSTATION; BUILDING 8 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW EAST-NORTHEAST OF TRANSFORMER BAYS AND SUB-STATION; BUILDING 8 IS AT EXTREME LEFT CENTER; BUILD-ING 50 IS VISIBLE AT LEFT CENTER BEHIND BUILDING 8 - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT

  14. Study on the system-level test method of digital metering in smart substation

    NASA Astrophysics Data System (ADS)

    Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing

    2017-03-01

    Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.

  15. Gauche Ethyl Alcohol: Laboratory Assignments and Interstellar Identification

    NASA Technical Reports Server (NTRS)

    Pearson, J. C.; Sastry, K. V. L. N.; Herbst, Eric; DeLucia, Frank C.

    1997-01-01

    Ethyl alcohol (ethanol) is known to possess a pair of closely spaced excited torsional substates (gauche+, gauche-) at an energy of approximately 57 K above the ground (trans) torsional substate. We report an extended analysis of some gauche - gauche+ Q-branch ((Delta)J = 0) transitions with a three-substate fixed frame axis method (FFAM) Hamiltonian. Our approach accounts for complex trans-gauche interactions for the first time. In addition, we are able to obtain intensities for perturbed rotational transitions, and to determine the trans to gauche+ separation to be 1185399.1 MHz. A complete ground state rotational-torsional partition function accounting for the previously neglected gauche substates is presented. Based on our analysis, a total of 14 U lines obtained towards Orion KL can now be assigned to gauche substates of ethanol. Analysis of these lines yields a rotational temperature of 223 K and a total (trans + gauche) column density of 7.0 x 10(exp 15)/sq cm. The column density is in reasonable agreement with the recent value of 2-3 x 10(exp 15)/sq cm based on observations of trans-ethanol by Ohishi et al., although there is some disparity in the rotational temperatures. Eight additional U lines in the literature are assigned to transitions of gauche ethanol.

  16. 47. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. VIEW OF STAGE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. VIEW OF STAGE TRANSMITTER AT ALTON, ILLINOIS MODEL SECTION, AND LOCK AND DAM (OLD #26) SIMULATOR. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  17. 7. VIEW OF THE MODERN SUBSTATION (FOREGROUND), WITH THE OLD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF THE MODERN SUBSTATION (FOREGROUND), WITH THE OLD SWITCHING BUILDING IN THE BACKGROUND, LOOKING SOUTHWEST. - Washington Water Power Company Post Falls Power Plant, Middle Channel Powerhouse & Dam, West of intersection of Spokane & Fourth Streets, Post Falls, Kootenai County, ID

  18. Harmonic Characteristics of Rectifier Substations and Their Impact on Audio Frequency Track Circuits

    DOT National Transportation Integrated Search

    1982-05-01

    This report describes the basic operation of substation rectifier equipment and the modes of possible interference with audio frequency track circuits used for train detection, cab signalling, and vehicle speed control. It also includes methods of es...

  19. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  20. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  1. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  2. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  3. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  4. DC Cable for Railway

    NASA Astrophysics Data System (ADS)

    Tomita, Masaru

    The development of a superconducting cable for railways has commenced, assuming that a DC transmission cable will be used for electric trains. The cable has been fabricated based on the results of current testing of a superconducting wire, and various evaluation tests have been performed to determine the characteristics of the cable. A superconducting transmission cable having zero electrical resistance and suitable for railway use is expected to enhance regeneration efficiency, reduce power losses, achieve load leveling and integration of sub-stations, and reduce rail potential.

  5. Fire protection system HMI in power plant

    NASA Astrophysics Data System (ADS)

    Zainal, Yuda Bakti

    2015-05-01

    The central power station, a place where there are machines that generate power, equipped with substation where the voltage is produced by the generator and increased to a certain voltage with a step up voltage transformer. Effect on transformer oil is very important, transformer may malfunction if the oil that serves as a coolant and insulator gradually decreased its ability, over time their use. Power transformer on usability is vital, so it needs to be maintained so that the temperature rise must be overcome by applying a temperature control that can inform and control the control valve to open the hydrant tap transformer cooling. HMI implemented to facilitate the operators cope with excess heat in the transformer using thermocouple censor. Test results show that the control transformer and monitored using PLC and HMI. Transformer can maintain the condition of a maximum of 80 degrees Celsius heat.

  6. 78 FR 50026 - Basin Electric Power Cooperative, Inc.: Notice of Intent To Prepare a Supplemental Draft...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-16

    ... transmission lines, 5 new substations, modifications to 4 existing substations, maintenance access roads... address the construction, operation, and maintenance of Basin Electric's proposed Project. The Project includes construction, operation and maintenance of approximately 275 [[Page 50027

  7. Kennedy Space Center, Space Shuttle Processing, and International Space Station Program Overview

    NASA Technical Reports Server (NTRS)

    Higginbotham, Scott Alan

    2011-01-01

    Topics include: International Space Station assembly sequence; Electrical power substation; Thermal control substation; Guidance, navigation and control; Command data and handling; Robotics; Human and robotic integration; Additional modes of re-supply; NASA and International partner control centers; Space Shuttle ground operations.

  8. A Fuzzy-Based Control Method for Smoothing Power Fluctuations in Substations along High-Speed Railways

    NASA Astrophysics Data System (ADS)

    Sugio, Tetsuya; Yamamoto, Masayoshi; Funabiki, Shigeyuki

    The use of an SMES (Superconducting Magnetic Energy Storage) for smoothing power fluctuations in a railway substation has been discussed. This paper proposes a smoothing control method based on fuzzy reasoning for reducing the SMES capacity at substations along high-speed railways. The proposed smoothing control method comprises three countermeasures for reduction of the SMES capacity. The first countermeasure involves modification of rule 1 for smoothing out the fluctuating electric power to its average value. The other countermeasures involve the modification of the central value of the stored energy control in the SMES and revision of the membership function in rule 2 for reduction of the SMES capacity. The SMES capacity in the proposed smoothing control method is reduced by 49.5% when compared to that in the nonrevised control method. It is confirmed by computer simulations that the proposed control method is suitable for smoothing out power fluctuations in substations along high-speed railways and for reducing the SMES capacity.

  9. Irvine Smart Grid Demonstration, a Regional Smart Grid Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yinger, Robert; Irwin, Mark

    ISGD was a comprehensive demonstration that spanned the electricity delivery system and extended into customer homes. The project used phasor measurement technology to enable substation-level situational awareness, and demonstrated SCE’s next-generation substation automation system. It extended beyond the substation to evaluate the latest generation of distribution automation technologies, including looped 12-kV distribution circuit topology using URCIs. The project team used DVVC capabilities to demonstrate CVR. In customer homes, the project evaluated HAN devices such as smart appliances, programmable communicating thermostats, and home energy management components. The homes were also equipped with energy storage, solar PV systems, and a number ofmore » energy efficiency measures (EEMs). The team used one block of homes to evaluate strategies and technologies for achieving ZNE. A home achieves ZNE when it produces at least as much renewable energy as the amount of energy it consumes annually. The project also assessed the impact of device-specific demand response (DR), as well as load management capabilities involving energy storage devices and plug-in electric vehicle charging equipment. In addition, the ISGD project sought to better understand the impact of ZNE homes on the electric grid. ISGD’s SENet enabled end-to-end interoperability between multiple vendors’ systems and devices, while also providing a level of cybersecurity that is essential to smart grid development and adoption across the nation. The ISGD project includes a series of sub-projects grouped into four logical technology domains: Smart Energy Customer Solutions, Next-Generation Distribution System, Interoperability and Cybersecurity, and Workforce of the Future. Section 2.3 provides a more detailed overview of these domains.« less

  10. 42. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 GALLON PER MINUTE INFLOW CONTROLLER WITH NEW PROGRAMMER, LOCATED ALONG THE NATCHEZ SECTION OF THE MODEL. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  11. Public magnetic field exposure based on internal current density for electric low voltage systems.

    PubMed

    Keikko, Tommi; Seesvuori, Reino; Hyvönen, Martti; Valkealahti, Seppo

    2009-04-01

    A measurement concept utilizing a new magnetic field exposure metering system has been developed for indoor substations where voltage is transformed from a medium voltage of 10 or 20 kV to a low voltage of 400 V. The new metering system follows the guidelines published by the International Commission on Non-Ionizing Radiation Protection. It can be used to measure magnetic field values, total harmonic distortion of the magnetic field, magnetic field exposure ratios for public and workers, load current values, and total harmonic distortion of the load current. This paper demonstrates how exposure to non-sinusoidal magnetic fields and magnetic flux density exposure values can be compared directly with limit values for internal current densities in a human body. Further, we present how the magnetic field and magnetic field exposure behaves in the vicinity of magnetic field sources within the indoor substation and in the neighborhood. Measured magnetic fields around the substation components have been used to develop a measurement concept by which long-term measurements in the substations were performed. Long-term measurements revealed interesting and partly unexpected dependencies between the measured quantities, which have been further analyzed. The principle of this paper is to substitute a demanding exposure measurement with measurements of the basic quantities like the 50 Hz fundamental magnetic field component, which can be estimated based on the load currents for certain classes of substation lay-out.

  12. 43. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 GALLON PER MINUTE INFLOW CONTROLLER WITH NEW PROGRAMMER, LOCATED ALONG THE NATCHEZ SECTION OF THE MODEL. NOTE CONTROL BUILDING AT LEFT. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  13. 18. Photocopy of photograph showing foundation framing of South Bank ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Photocopy of photograph showing foundation framing of South Bank Substation, 11 June 1939 (from the BPA Photo Archives, Negative No. 347), LOOKING NORTH WITH THE BONNEVILLE DAM POWERHOUSE IN BACKGROUND - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  14. 123. ARAI Substation (ARA726) plan, elevation, security fence details, and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    123. ARA-I Substation (ARA-726) plan, elevation, security fence details, and sections. Norman Engineering Company 961-area/SF-726-E-1. Date: January 1959. Ineel index code no. 068-0726-10-613-102778. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  15. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric substations and liquid storage...

  16. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric substations and liquid storage...

  17. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric substations and liquid storage...

  18. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric substations and liquid storage...

  19. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR DEVELOPMENT AND IMPLEMENTATION OF STATE SOLID WASTE...

  20. 19. Photocopy of photograph showing framing of concrete walls of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Photocopy of photograph showing framing of concrete walls of South Bank Substation, 18 July 1939 (from the BPA Photo Archives, Negative No. 365), LOOKING NORTHWEST WITH THE BONNEVILLE DAM POWERHOUSE IN BACKGROUND - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  1. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  2. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  3. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  4. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  5. 75 FR 7470 - Pine Prairie Energy Center, LLC; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    ... electric motor drive compressor units instead of the four 4,700 hp natural gas-fueled units previously authorized; (2) construct and operate a new electrical substation at the Pine Prairie Gas Handling Facility and approximately 1,200 feet of aerial electric power lines between the new substation and the...

  6. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  7. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  8. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  9. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  10. Identification and Single-Cell Functional Characterization of an Endodermally Biased Pluripotent Substate in Human Embryonic Stem Cells.

    PubMed

    Allison, Thomas F; Smith, Andrew J H; Anastassiadis, Konstantinos; Sloane-Stanley, Jackie; Biga, Veronica; Stavish, Dylan; Hackland, James; Sabri, Shan; Langerman, Justin; Jones, Mark; Plath, Kathrin; Coca, Daniel; Barbaric, Ivana; Gokhale, Paul; Andrews, Peter W

    2018-05-09

    Human embryonic stem cells (hESCs) display substantial heterogeneity in gene expression, implying the existence of discrete substates within the stem cell compartment. To determine whether these substates impact fate decisions of hESCs we used a GFP reporter line to investigate the properties of fractions of putative undifferentiated cells defined by their differential expression of the endoderm transcription factor, GATA6, together with the hESC surface marker, SSEA3. By single-cell cloning, we confirmed that substates characterized by expression of GATA6 and SSEA3 include pluripotent stem cells capable of long-term self-renewal. When clonal stem cell colonies were formed from GATA6-positive and GATA6-negative cells, more of those derived from GATA6-positive cells contained spontaneously differentiated endoderm cells than similar colonies derived from the GATA6-negative cells. We characterized these discrete cellular states using single-cell transcriptomic analysis, identifying a potential role for SOX17 in the establishment of the endoderm-biased stem cell state. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Progress in American Superconductor's HTS wire and optimization for fault current limiting systems

    NASA Astrophysics Data System (ADS)

    Malozemoff, Alexis P.

    2016-11-01

    American Superconductor has developed composite coated conductor tape-shaped wires using high temperature superconductor (HTS) on a flexible substrate with laminated metal stabilizer. Such wires enable many applications, each requiring specific optimization. For example, coils for HTS rotating machinery require increased current density J at 25-50 K. A collaboration with Argonne, Brookhaven and Los Alamos National Laboratories and several universities has increased J using an optimized combination of precipitates and ion irradiation defects in the HTS. Major commercial opportunities also exist to enhance electric power grid resiliency by linking substations with distribution-voltage HTS power cables [10]. Such links provide alternative power sources if one substation's transmission-voltage power is compromised. But they must also limit fault currents which would otherwise be increased by such distribution-level links. This can be done in an HTS cable, exploiting the superconductor-to-resistive transition when current exceeds the wires' critical J. A key insight is that such transitions are usually nonuniform; so the wire must be designed to prevent localized hot spots from damaging the wire or even generating gas bubbles in the cable causing dielectric breakdown. Analysis shows that local heating can be minimized by increasing the composite tape's total thickness, decreasing its total resistance in the normal state and decreasing its critical J. This conflicts with other desirable wire characteristics. Optimization of these conflicting requirements is discussed.

  12. Substrate solder barriers for semiconductor epilayer growth

    DOEpatents

    Drummond, T.J.; Ginley, D.S.; Zipperian, T.E.

    1987-10-23

    During the growth of compound semiconductors by epitaxial processes, substrates are typically mounted to a support. In molecular beam epitaxy, mounting is done using indium as a solder. This method has two drawbacks: the indium reacts with the substrate, and it is difficult to uniformly wet the back of a large diameter substrate. Both of these problems have been successfully overcome by sputter coating the back of the substrate with a thin layer of tungsten carbide or tungsten carbide and gold. In addition to being compatible with the growth of high quality semiconductor epilayers this coating is also inert in all standard substate cleaning etchants used for compound semiconductors, and provides uniform distribution of energy in radiant heating. 1 tab.

  13. 43. Photographic copy of photograph, dated September 1973 (original print ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. Photographic copy of photograph, dated September 1973 (original print in possession of CSSD-HO, Huntsville, AL). Photographer unknown. Aerial view (southwest to northeast) of perimeter acquisition radar building, showing tactical and nontactical support buildings. From lest hand corner, note storage building (#709); to the right, gymnasium (715). Next row, left to BOQ (#708); Bachelor's enlisted men's quarters (#720). Above #720 can be seen industrial building (#730), and above that, a substation (#740). Below PARB, to left and right, are PARPP exhaust shafts and heat sink (#813) - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Building, Limited Access Area, between Limited Access Patrol Road & Service Road A, Nekoma, Cavalier County, ND

  14. Quantum coherence in photo-ionisation with tailored XUV pulses

    NASA Astrophysics Data System (ADS)

    Carlström, Stefanos; Mauritsson, Johan; Schafer, Kenneth J.; L'Huillier, Anne; Gisselbrecht, Mathieu

    2018-01-01

    Ionisation with ultrashort pulses in the extreme ultraviolet (XUV) regime can be used to prepare an ion in a superposition of spin-orbit substates. In this work, we study the coherence properties of such a superposition, created by ionising xenon atoms using two phase-locked XUV pulses at different frequencies. In general, if the duration of the driving pulse exceeds the quantum beat period, dephasing will occur. If however, the frequency difference of the two pulses matches the spin-orbit splitting, the coherence can be efficiently increased and dephasing does not occur.

  15. 77 FR 73651 - Cascade Energy Storage, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-11

    ... City Light's existing 230-kV transmission line, or (ii) Bonneville Power Administration's (BPA) existing Custer-Monroe 500-kV line, or (iii) BPA existing Murray substation, or (iv) a new 4.5-mile- long... and then to the BPA Murray substation; and (9) appurtenant facilities. The estimated annual generation...

  16. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-74)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-07-01

    Vegetation Management for five Substations in the Malin District. BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Malin District of the Redmond Region.

  17. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-82)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-08-13

    Vegetation Management for twenty-four Substations in the Burley District. BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Burley District of the Idaho Falls Region.

  18. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-78)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-07-01

    Vegetation Management for ten Substations in the Redmond District. BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Redmond District of the Redmond Region.

  19. CENet: A Cabinet Environmental Sensing Network

    PubMed Central

    Zhang, Zusheng; Yu, Fengqi; Chen, Liang; Cao, Guangmin

    2010-01-01

    For data center cooling and intelligent substation systems, real time cabinet environmental monitoring is a strong requirement. Monitoring data, such as temperature, humidity, and noise, is important for operators to manage the facilities in cabinets. We here propose a sensing network, called CENet, which is energy efficient and reliable for cabinet environmental monitoring. CENet achieves above 93% reliable data yield and sends fewer beacons compared to periodic beaconing. It does so through a data-aided routing protocol. In addition, based on B-MAC, we propose a scheduling scheme to increase the lifetime of the network by reducing unnecessary message snooping and channel listening, thus it is more energy efficient than B-MAC. The performance of CENet is evaluated by simulations and experiments. PMID:22205856

  20. View west of load dispatch model board; section covers substations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west of load dispatch model board; section covers substations from edgerly (right) to thorndale and west yard (left). Instruments at bottom of center board section formerly monitored energy usage and were replaced by a computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  1. 16. EXTERIOR NORTH END OF TULE RIVER POWERHOUSE SHOWING POWERHOUSE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. EXTERIOR NORTH END OF TULE RIVER POWERHOUSE SHOWING POWERHOUSE AT PHOTO CENTER, SUBSTATION AT PHOTO RIGHT FOREGROUND, OFFICE BEHIND SUBSTATION AT RIGHT OF POWERHOUSE, AND MACHINE SHOP AT LEFT OF POWERHOUSE. THIS PHOTOGRAPH DUPLICATES HISTORIC VIEW SHOWN IN PHOTO CA-216-17. VIEW TO SOUTHEAST. - Tule River Hydroelectric Project, Water Conveyance System, Middle Fork Tule River, Springville, Tulare County, CA

  2. Procedures and criteria for increasing the earthquake resistance level of electrical substations and special installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Couch, R.W.; Deacon, R.J.

    1973-09-30

    This report defines a procedure and provides basic information needed to determine the modifications required to make electrical substations and special installations of the Bonneville Power Administration (BPA) more resistant to strong earthquake ground motion. It also provides a procedure for developing an effective plan for establishing the sequence, or priority, of providing the required modifications.

  3. 78 FR 70546 - Erie Boulevard Hydropower, L.P.; Notice of Application Accepted for Filing, Soliciting Motions To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... (kV) generator leads extending about 25 feet to an adjacent electrical substation containing a 2.4/4.8-kV, 600-kilovolt-amperes, step-up transformer bank. A transmission line owned and operated by... with the electrical grid at the substation. At the time the Commission issued the original license for...

  4. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-96) - Snohomish District Substations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermeston, Mark W.

    2002-07-19

    Proposed Action: Vegetation Management for facilities located in the Snohomish District. BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Snohomish District of the Snohomish Region.

  5. 78 FR 62348 - Erie Boulevard Hydropower L.P.; Notice of Application Tendered for Filing With the Commission and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-18

    ... 100 feet; and (7) 2.4-kilovolt (kV) generator leads extending about 25 feet to an adjacent electrical substation containing a 2.4/4.8-kV, 600-kilovolt-amperes, step-up transformer bank. A transmission line owned... project interconnects with the electrical grid at the substation. At the time the Commission issued the...

  6. Service Building No. 620. Detail of north elevation and entrance ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Service Building No. 620. Detail of north elevation and entrance to substation & windowns in top of elevator shafts no. 2 & stair no. 1 & section thru substation (dry dock associates, June 12, 1941). In files of Cushman & Wakefield, building 501, Philadelphia Naval Business Center. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Service Building, Dry Docks No. 4 & 5, League Island, Philadelphia, Philadelphia County, PA

  7. Design of a two-level power system linear state estimator

    NASA Astrophysics Data System (ADS)

    Yang, Tao

    The availability of synchro-phasor data has raised the possibility of a linear state estimator if the inputs are only complex currents and voltages and if there are enough such measurements to meet observability and redundancy requirements. Moreover, the new digital substations can perform some of the computation at the substation itself resulting in a more accurate two-level state estimator. The objective of this research is to develop a two-level linear state estimator processing synchro-phasor data and estimating the states at both the substation level and the control center level. Both the mathematical algorithms that are different from those in the present state estimation procedure and the layered architecture of databases, communications and application programs that are required to support this two-level linear state estimator are described in this dissertation. Besides, as the availability of phasor measurements at substations will increase gradually, this research also describes how the state estimator can be enhanced to handle both the traditional state estimator and the proposed linear state estimator simultaneously. This provides a way to immediately utilize the benefits in those parts of the system where such phasor measurements become available and provides a pathway to transition to the smart grid of the future. The design procedure of the two-level state estimator is applied to two study systems. The first study system is the IEEE-14 bus system. The second one is the 179 bus Western Electricity Coordinating Council (WECC) system. The static database for the substations is constructed from the power flow data of these systems and the real-time measurement database is produced by a power system dynamic simulating tool (TSAT). Time-skew problems that may be caused by communication delays are also considered and simulated. We used the Network Simulator (NS) tool to simulate a simple communication system and analyse its time delay performance. These time delays were too small to affect the results especially since the measurement data is time-stamped and the state estimator for these small systems could be run with subseconf frequency. Keywords: State Estimation, Synchro-Phasor Measurement, Distributed System, Energy Control Center, Substation, Time-skew

  8. Hazard zoning around electric substations of petrochemical industries by stimulation of extremely low-frequency magnetic fields.

    PubMed

    Hosseini, Monireh; Monazzam, Mohammad Reza; Farhang Matin, Laleh; Khosroabadi, Hossein

    2015-05-01

    Electromagnetic fields in recent years have been discussed as one of the occupational hazards at workplaces. Hence, control and assessment of these physical factors is very important to protect and promote the health of employees. The present study was conducted to determine hazard zones based on assessment of extremely low-frequency magnetic fields at electric substations of a petrochemical complex in southern Iran, using the single-axis HI-3604 device. In measurement of electromagnetic fields by the single-axis HI-3604 device, the sensor screen should be oriented in a way to be perpendicular to the field lines. Therefore, in places where power lines are located in different directions, it is required to keep the device towards three axes of x, y, and z. For further precision, the measurements should be repeated along each of the three axes. In this research, magnetic field was measured, for the first time, in three axes of x, y, and z whose resultant value was considered as the value of magnetic field. Measurements were done based on IEEE std 644-1994. Further, the spatial changes of the magnetic field surrounding electric substations were stimulated using MATLAB software. The obtained results indicated that the maximum magnetic flux density was 49.90 μT recorded from boiler substation, while the minimum magnetic flux density of 0.02 μT was measured at the control room of the complex. As the stimulation results suggest, the spaces around incoming panels, transformers, and cables were recognized as hazardous zones of indoor electric substations. Considering the health effects of chronic exposure to magnetic fields, it would be possible to minimize exposure to these contaminants at workplaces by identification of risky zones and observation of protective considerations.

  9. Inter and intra substation communications: Requirements and solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamiak, M.; Patterson, R.; Melcher, J.

    1995-10-01

    As the substation communication world searches for the ``Promised LAN,`` it would be helpful to have a roadmap to give direction to the search. Many are the expectations of a LAN flowing with data and able to connect with any Intelligent Electronic Device (IED) that was ever made. Such expectations must be tempered with the cost and complexity of achieving them. This paper presents an outline of the communication requirements of the myriad of IED`s in existence in the substation today as well as the expectations of what second generation microprocessor based devices might be able to do. Requirements willmore » focus on language issues, system capabilities, performance requirements, external interfaces, environmental, and quality issues. Some attention will also be given to the architecture of a solution and some guidelines as to how this structure might be built.« less

  10. Autonomous navigation method for substation inspection robot based on travelling deviation

    NASA Astrophysics Data System (ADS)

    Yang, Guoqing; Xu, Wei; Li, Jian; Fu, Chongguang; Zhou, Hao; Zhang, Chuanyou; Shao, Guangting

    2017-06-01

    A new method of edge detection is proposed in substation environment, which can realize the autonomous navigation of the substation inspection robot. First of all, the road image and information are obtained by using an image acquisition device. Secondly, the noise in the region of interest which is selected in the road image, is removed with the digital image processing algorithm, the road edge is extracted by Canny operator, and the road boundaries are extracted by Hough transform. Finally, the distance between the robot and the left and the right boundaries is calculated, and the travelling distance is obtained. The robot's walking route is controlled according to the travel deviation and the preset threshold. Experimental results show that the proposed method can detect the road area in real time, and the algorithm has high accuracy and stable performance.

  11. Energy Saving in DC Electric Railways by Battery Substation

    NASA Astrophysics Data System (ADS)

    Sugimoto, Takeshi

    New rolling vehicles used in dc electric railways are of the regenerative type. At less busy time a part of regenerative power is not used for powering vehicles, and canceled by changed air brake. Recently, significant attention has been paid to the development of secondary batteries for hybrid and electric motorcars. The use of this battery enables reduction in electric power consumption. Because we can charge excess regenerative power and use for powering vehicles after. Before the fact we compared the actual and simulated effective coefficient of regenerative energy, we confirmed the suitability of the simulation model. In this simulation, we studied the energy-saving effect of the battery substations and determined the battery capacity at which maximum power saving is achieved. We found that the power consumption could be reduced remarkably by using a 15-20kWh battery substation.

  12. Geometric analysis characterizes molecular rigidity in generic and non-generic protein configurations

    PubMed Central

    Budday, Dominik; Leyendecker, Sigrid; van den Bedem, Henry

    2015-01-01

    Proteins operate and interact with partners by dynamically exchanging between functional substates of a conformational ensemble on a rugged free energy landscape. Understanding how these substates are linked by coordinated, collective motions requires exploring a high-dimensional space, which remains a tremendous challenge. While molecular dynamics simulations can provide atomically detailed insight into the dynamics, computational demands to adequately sample conformational ensembles of large biomolecules and their complexes often require tremendous resources. Kinematic models can provide high-level insights into conformational ensembles and molecular rigidity beyond the reach of molecular dynamics by reducing the dimensionality of the search space. Here, we model a protein as a kinematic linkage and present a new geometric method to characterize molecular rigidity from the constraint manifold Q and its tangent space Q at the current configuration q. In contrast to methods based on combinatorial constraint counting, our method is valid for both generic and non-generic, e.g., singular configurations. Importantly, our geometric approach provides an explicit basis for collective motions along floppy modes, resulting in an efficient procedure to probe conformational space. An atomically detailed structural characterization of coordinated, collective motions would allow us to engineer or allosterically modulate biomolecules by selectively stabilizing conformations that enhance or inhibit function with broad implications for human health. PMID:26213417

  13. Geometric analysis characterizes molecular rigidity in generic and non-generic protein configurations

    NASA Astrophysics Data System (ADS)

    Budday, Dominik; Leyendecker, Sigrid; van den Bedem, Henry

    2015-10-01

    Proteins operate and interact with partners by dynamically exchanging between functional substates of a conformational ensemble on a rugged free energy landscape. Understanding how these substates are linked by coordinated, collective motions requires exploring a high-dimensional space, which remains a tremendous challenge. While molecular dynamics simulations can provide atomically detailed insight into the dynamics, computational demands to adequately sample conformational ensembles of large biomolecules and their complexes often require tremendous resources. Kinematic models can provide high-level insights into conformational ensembles and molecular rigidity beyond the reach of molecular dynamics by reducing the dimensionality of the search space. Here, we model a protein as a kinematic linkage and present a new geometric method to characterize molecular rigidity from the constraint manifold Q and its tangent space Tq Q at the current configuration q. In contrast to methods based on combinatorial constraint counting, our method is valid for both generic and non-generic, e.g., singular configurations. Importantly, our geometric approach provides an explicit basis for collective motions along floppy modes, resulting in an efficient procedure to probe conformational space. An atomically detailed structural characterization of coordinated, collective motions would allow us to engineer or allosterically modulate biomolecules by selectively stabilizing conformations that enhance or inhibit function with broad implications for human health.

  14. Digital combined instrument transformer for automated electric power supply control systems of mining companies

    NASA Astrophysics Data System (ADS)

    Topolsky, D. V.; Gonenko, T. V.; Khatsevskiy, V. F.

    2017-10-01

    The present paper discusses ways to solve the problem of enhancing operating efficiency of automated electric power supply control systems of mining companies. According to the authors, one of the ways to solve this problem is intellectualization of the electric power supply control system equipment. To enhance efficiency of electric power supply control and electricity metering, it is proposed to use specially designed digital combined instrument current and voltage transformers. This equipment conforms to IEC 61850 international standard and is adapted for integration into the digital substation structure. Tests were performed to check conformity of an experimental prototype of the digital combined instrument current and voltage transformer with IEC 61850 standard. The test results have shown that the considered equipment meets the requirements of the standard.

  15. USSR and Eastern Europe Scientific Abstracts, Cybernetics, Computers and Automation Technology, Number 31

    DTIC Science & Technology

    1978-02-09

    incorporation of subsystems and tasks into systems are specified by state and industrial- sector standards. However, such rigid requirements interfere...construction of the step-down substation, without which the new sector is inoperable. The question of who will build the substation is still unresolved... economico -mathematical evaluation). Among such applications, program decks completed by the "Soyuzsistemprom" are those for data integra- tion and

  16. Conformational equilibria of light-activated rhodopsin in nanodiscs

    PubMed Central

    Van Eps, Ned; Caro, Lydia N.; Morizumi, Takefumi; Kusnetzow, Ana Karin; Szczepek, Michal; Hofmann, Klaus Peter; Bayburt, Timothy H.; Sligar, Stephen G.; Ernst, Oliver P.; Hubbell, Wayne L.

    2017-01-01

    Conformational equilibria of G-protein–coupled receptors (GPCRs) are intimately involved in intracellular signaling. Here conformational substates of the GPCR rhodopsin are investigated in micelles of dodecyl maltoside (DDM) and in phospholipid nanodiscs by monitoring the spatial positions of transmembrane helices 6 and 7 at the cytoplasmic surface using site-directed spin labeling and double electron–electron resonance spectroscopy. The photoactivated receptor in DDM is dominated by one conformation with weak pH dependence. In nanodiscs, however, an ensemble of pH-dependent conformational substates is observed, even at pH 6.0 where the MIIbH+ form defined by proton uptake and optical spectroscopic methods is reported to be the sole species present in native disk membranes. In nanodiscs, the ensemble of substates in the photoactivated receptor spontaneously decays to that characteristic of the inactive state with a lifetime of ∼16 min at 20 °C. Importantly, transducin binding to the activated receptor selects a subset of the ensemble in which multiple substates are apparently retained. The results indicate that in a native-like lipid environment rhodopsin activation is not analogous to a simple binary switch between two defined conformations, but the activated receptor is in equilibrium between multiple conformers that in principle could recognize different binding partners. PMID:28373559

  17. A comparative study of electric load curve changes in an urban low-voltage substation in Spain during the economic crisis (2008-2013).

    PubMed

    Lara-Santillán, Pedro M; Mendoza-Villena, Montserrat; Fernández-Jiménez, L Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008-2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002-2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period.

  18. Draft Supplement to the Environmental Statement Fiscal Year 1976 Proposed Program : Facilty Location Evaluation for Franklin-Badger Canyon 230-kV Line and Badger Canyon Substation Study Area 74-6B.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration.

    1974-10-22

    Proposed is the construction of a 15-mile, 230-kV double-circuit transmission line from Franklin Substation near Pasco, Washington, to a proposed new Badger Canyon Substation to be constructed 5 miles west of Kennewick, Washington. Depending on the final route location chosen, approximately 15 miles of 230-kV double circuit transmission line requiring 5.6 miles of new and 9.4 miles of existing right-of-way would be needed as well as approximately 2500 feet of new access road. Land use affected includes crossing Sacajawea State Park and passig through irrigated cropland and grassland on existing right-of-way, and depending on the alternative route chosen, could crossmore » land proposed for residential development and a proposed interstate highway. An additional 10 to 11 acres of potential cropland would be required for the proposed substation. Disturbance to wildlife during construction would occur and habitat associated with the above land uses would be eliminated. Some erosion and sedimentation would occur. Visual impacts would affect Sacajawea State Park, a proposed highway, and potential residential development land. Noise and other disturbances to residents will occur, primarily during construction.« less

  19. Kinematic analysis and simulation of a substation inspection robot guided by magnetic sensor

    NASA Astrophysics Data System (ADS)

    Xiao, Peng; Luan, Yiqing; Wang, Haipeng; Li, Li; Li, Jianxiang

    2017-01-01

    In order to improve the performance of the magnetic navigation system used by substation inspection robot, the kinematic characteristics is analyzed based on a simplified magnetic guiding system model, and then the simulation process is executed to verify the reasonability of the whole analysis procedure. Finally, some suggestions are extracted out, which will be helpful to guide the design of the inspection robot system in the future.

  20. 20 CFR 645.210 - What is meant by the terms “entity” and “project” in the statutory phrase “an entity that...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... a project”, means: (a) For WtW substate formula funds: (1) “Entity” means the PIC, local board (or... to § 645.400 of this part) which administers the WtW substate formula funds in a local area(s). This... formula funds allotted to the entity described in section (a)(1) of this paragraph. (b) For WtW Governors...

  1. 20 CFR 645.210 - What is meant by the terms “entity” and “project” in the statutory phrase “an entity that...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... a project”, means: (a) For WtW substate formula funds: (1) “Entity” means the PIC, local board (or... to § 645.400 of this part) which administers the WtW substate formula funds in a local area(s). This... formula funds allotted to the entity described in section (a)(1) of this paragraph. (b) For WtW Governors...

  2. Supplemental Environmental Assessment: Lighthouse Substation Cape Canaveral Air Force Station Florida

    DTIC Science & Technology

    2007-10-01

    associated with transmission lines is generally due to either corona or “spark gap” discharges. When the electric field at the surface of a conductor... corona , will be initiated from the conductor into the Chapter 3: Affected Environment Supplemental Environmental Assessment – Lighthouse Substation at...Cape Canaveral Air Force Station 24 surrounding air. The intensity of the corona increases with the voltage of the line and is dependent on the

  3. Two-way communication and analysis program on LANDSAT

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Community workshops, field visits, telephone surveys, and other research reveals that professionals at the substate level are interested in and open to consideration of LANDSAT as a planning and resource management tool, but are at the same time skeptical about some of the inherent problems with LANDSAT such as cost, resolution, frequency of coverage, and data continuity. The principal requirements for increasing the utilization of LANDSAT by potential substate users were identified and documented. Without a committment from the Federal Government for increased substrate utilization and the availability of trained professionals to meet the needs of a largely new user community, substrate activity is likely to remain at a minimum. Well conceived and well executed demonstration projects could play a critical role is shaping the technology's ability to be more sensitive to substate user needs and interests as well as validating the effectiveness of this data to a skeptical audience.

  4. Design of online monitoring and forecasting system for electrical equipment temperature of prefabricated substation based on WSN

    NASA Astrophysics Data System (ADS)

    Qi, Weiran; Miao, Hongxia; Miao, Xuejiao; Xiao, Xuanxuan; Yan, Kuo

    2016-10-01

    In order to ensure the safe and stable operation of the prefabricated substations, temperature sensing subsystem, temperature remote monitoring and management subsystem, forecast subsystem are designed in the paper. Wireless temperature sensing subsystem which consists of temperature sensor and MCU sends the electrical equipment temperature to the remote monitoring center by wireless sensor network. Remote monitoring center can realize the remote monitoring and prediction by monitoring and management subsystem and forecast subsystem. Real-time monitoring of power equipment temperature, history inquiry database, user management, password settings, etc., were achieved by monitoring and management subsystem. In temperature forecast subsystem, firstly, the chaos of the temperature data was verified and phase space is reconstructed. Then Support Vector Machine - Particle Swarm Optimization (SVM-PSO) was used to predict the temperature of the power equipment in prefabricated substations. The simulation results found that compared with the traditional methods SVM-PSO has higher prediction accuracy.

  5. Tracking problem solving by multivariate pattern analysis and Hidden Markov Model algorithms.

    PubMed

    Anderson, John R

    2012-03-01

    Multivariate pattern analysis can be combined with Hidden Markov Model algorithms to track the second-by-second thinking as people solve complex problems. Two applications of this methodology are illustrated with a data set taken from children as they interacted with an intelligent tutoring system for algebra. The first "mind reading" application involves using fMRI activity to track what students are doing as they solve a sequence of algebra problems. The methodology achieves considerable accuracy at determining both what problem-solving step the students are taking and whether they are performing that step correctly. The second "model discovery" application involves using statistical model evaluation to determine how many substates are involved in performing a step of algebraic problem solving. This research indicates that different steps involve different numbers of substates and these substates are associated with different fluency in algebra problem solving. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. The power grid monitoring promotion of Liaoning December 14th accident

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Gao, Ziji; He, Xiaoyang; Li, Tie; Jin, Xiaoming; Wang, Mingkai; Qu, Zhi; Sun, Chenguang

    2018-02-01

    This paper introduces the main responsibilities of power grid monitoring and the accident of Liaoning Power Grid 500kV Xujia transformer substation at December 14th, 2016. This paper analyzes the problems exposed in this accident from the aspects of abnormal information judgment, fault information collection, auxiliary video monitoring, online monitoring of substation equipment, puts forward the corresponding improvement methods and summarizes the methods of improving the professional level of power grid equipment monitoring.

  7. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013)

    PubMed Central

    Lara-Santillán, Pedro M.; Mendoza-Villena, Montserrat; Fernández-Jiménez, L. Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008–2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period. PMID:24895677

  8. National Maglev initiative: California line electric utility power system requirements

    NASA Technical Reports Server (NTRS)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  9. Modeling of District Heating Networks for the Purpose of Operational Optimization with Thermal Energy Storage

    NASA Astrophysics Data System (ADS)

    Leśko, Michał; Bujalski, Wojciech

    2017-12-01

    The aim of this document is to present the topic of modeling district heating systems in order to enable optimization of their operation, with special focus on thermal energy storage in the pipelines. Two mathematical models for simulation of transient behavior of district heating networks have been described, and their results have been compared in a case study. The operational optimization in a DH system, especially if this system is supplied from a combined heat and power plant, is a difficult and complicated task. Finding a global financial optimum requires considering long periods of time and including thermal energy storage possibilities into consideration. One of the most interesting options for thermal energy storage is utilization of thermal inertia of the network itself. This approach requires no additional investment, while providing significant possibilities for heat load shifting. It is not feasible to use full topological models of the networks, comprising thousands of substations and network sections, for the purpose of operational optimization with thermal energy storage, because such models require long calculation times. In order to optimize planned thermal energy storage actions, it is necessary to model the transient behavior of the network in a very simple way - allowing for fast and reliable calculations. Two approaches to building such models have been presented. Both have been tested by comparing the results of simulation of the behavior of the same network. The characteristic features, advantages and disadvantages of both kinds of models have been identified. The results can prove useful for district heating system operators in the near future.

  10. High temperature insulation for ceramic matrix composites

    DOEpatents

    Merrill, Gary B.; Morrison, Jay Alan

    2000-01-01

    A ceramic composition is provided to insulate ceramic matrix composites under high temperature, high heat flux environments. The composite comprises a plurality of hollow oxide-based spheres of varios dimentions, a phosphate binder, and at least one oxide filler powder, whereby the phosphate binder partially fills gaps between the spheres and the filler powders. The spheres are situated in the phosphate binder and the filler powders such that each sphere is in contact with at least one other sphere. The spheres may be any combination of Mullite spheres, Alumina spheres, or stabilized Zirconia spheres. The filler powder may be any combination of Alumina, Mullite, Ceria, or Hafnia. Preferably, the phosphate binder is Aluminum Ortho-Phosphate. A method of manufacturing the ceramic insulating composition and its application to CMC substates are also provided.

  11. Volt-VAR Optimization on American Electric Power Feeders in Northeast Columbus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, Kevin P.; Weaver, T. F.

    2012-05-10

    In 2007 American Electric Power launched the gridSMART® initiative with the goals of increasing efficiency of the electricity delivery system and improving service to the end-use customers. As part of the initiative, a coordinated Volt-VAR system was deployed on eleven distribution feeders at five substations in the Northeast Columbus Ohio Area. The goal of the coordinated Volt-VAR system was to decrease the amount of energy necessary to provide end-use customers with the same quality of service. The evaluation of the Volt-VAR system performance was conducted in two stages. The first stage was composed of simulation, analysis, and estimation, while themore » second stage was composed of analyzing collected field data. This panel paper will examine the analysis conducted in both stages and present the estimated improvements in system efficiency.« less

  12. Modelling GIC Flow in New Zealand's Electrical Transmission Grid

    NASA Astrophysics Data System (ADS)

    Divett, T.; Thomson, A. W. P.; Ingham, M.; Rodger, C. J.; Beggan, C.; Kelly, G.

    2016-12-01

    Transformers in Transpower New Zealand Ltd's electrical grid have been impacted by geomagnetically induced currents (GIC) during geomagnetic storms, for example in November 2001. In this study we have developed an initial model of the South Island's power grid to advance understanding of the impact of GIC on New Zealand's (NZ) grid. NZ's latitude and island setting mean that modelling approaches successfully used in the UK in the past can be used. Vasseur and Weidelt's thin sheet model is applied to model the electric field as a function of magnetic field and conductance. However the 4 km deep ocean near NZ's coast compared to the UK's relatively shallow continental shelf waters restricts the range of frequency and spatial grid that can be used due to assumptions in the thin sheet model. Some early consequences of these restrictions will be discussed. Lines carrying 220kV, 110kV and 66kV make up NZ's electrical transmission grid with multiple earthing nodes at each substation. Transpower have measured DC earth currents at 17 nodes in NZ's South Island grid for 15 years, including observations at multiple transformers for some substations. Different transformers at the same substation can experience quite different GIC during space weather events. Therefore we have initially modelled each transformer in some substations separately to compare directly with measured currents.Ultimately this study aims to develop a validated modelling tool that will be used to strengthen NZ's grid against the risks of space weather. Further, mitigation tactics which could be used to reduce the threat to the electrical grid will be evaluated. In particular we will focus at the transformer level where the risk lies, and not at the substation level as has been commonly done to date. As we will validate our model against the extensive Transpower observations, this will be a valuable confirmation of the approaches used by the wider international community.

  13. The research of full automatic oil filtering control technology of high voltage insulating oil

    NASA Astrophysics Data System (ADS)

    Gong, Gangjun; Zhang, Tong; Yan, Guozeng; Zhang, Han; Chen, Zhimin; Su, Chang

    2017-09-01

    In this paper, the design scheme of automatic oil filter control system for transformer oil in UHV substation is summarized. The scheme specifically includes the typical double tank filter connection control method of the transformer oil of the UHV substation, which distinguishes the single port and the double port connection structure of the oil tank. Finally, the design scheme of the temperature sensor and respirator is given in detail, and the detailed evaluation and application scenarios are given for reference.

  14. Image acquisition device of inspection robot based on adaptive rotation regulation of polarizer

    NASA Astrophysics Data System (ADS)

    Dong, Maoqi; Wang, Xingguang; Liang, Tao; Yang, Guoqing; Zhang, Chuangyou; Gao, Faqin

    2017-12-01

    An image processing device of inspection robot with adaptive polarization adjustment is proposed, that the device includes the inspection robot body, the image collecting mechanism, the polarizer and the polarizer automatic actuating device. Where, the image acquisition mechanism is arranged at the front of the inspection robot body for collecting equipment image data in the substation. Polarizer is fixed on the automatic actuating device of polarizer, and installed in front of the image acquisition mechanism, and that the optical axis of the camera vertically goes through the polarizer and the polarizer rotates with the optical axis of the visible camera as the central axis. The simulation results show that the system solves the fuzzy problems of the equipment that are caused by glare, reflection of light and shadow, and the robot can observe details of the running status of electrical equipment. And the full coverage of the substation equipment inspection robot observation target is achieved, which ensures the safe operation of the substation equipment.

  15. A Novel Wide-Area Backup Protection Based on Fault Component Current Distribution and Improved Evidence Theory

    PubMed Central

    Zhang, Zhe; Kong, Xiangping; Yin, Xianggen; Yang, Zengli; Wang, Lijun

    2014-01-01

    In order to solve the problems of the existing wide-area backup protection (WABP) algorithms, the paper proposes a novel WABP algorithm based on the distribution characteristics of fault component current and improved Dempster/Shafer (D-S) evidence theory. When a fault occurs, slave substations transmit to master station the amplitudes of fault component currents of transmission lines which are the closest to fault element. Then master substation identifies suspicious faulty lines according to the distribution characteristics of fault component current. After that, the master substation will identify the actual faulty line with improved D-S evidence theory based on the action states of traditional protections and direction components of these suspicious faulty lines. The simulation examples based on IEEE 10-generator-39-bus system show that the proposed WABP algorithm has an excellent performance. The algorithm has low requirement of sampling synchronization, small wide-area communication flow, and high fault tolerance. PMID:25050399

  16. A Study on Effect of Concrete Foundations on Resistance and Surface Potentials of Gas Insulated Substation Grounding Systems

    NASA Astrophysics Data System (ADS)

    Rao, Mandava Mohana

    2017-10-01

    Ground resistance of high voltage substations must be as low as possible for safe grounding of their equipment both during normal and fault conditions. However, in gas insulated substations (GIS), even though resistance is low, it does not ensure the step and touch potentials of the grounding system within permissible levels. In the present study, an analytical model has been developed to calculate ground resistance, step and touch potentials of a grounding system used for GIS. Different models have been proposed for the evaluation of number of grounding rods to be inserted in to the ground. The effect of concrete foundations on above performance parameters has been analyzed by considering various fault currents, soil/earth resistivities and number of grounding rods. Finally, design optimization of GIS grounding system has been reported for fault currents in the order of 63 kA located in earth resistivity of 100Ω-m and above.

  17. On-rail solution for autonomous inspections in electrical substations

    NASA Astrophysics Data System (ADS)

    Silva, Bruno P. A.; Ferreira, Rafael A. M.; Gomes, Selson C.; Calado, Flavio A. R.; Andrade, Roberto M.; Porto, Matheus P.

    2018-05-01

    This work presents an alternative solution for autonomous inspections in electrical substations. The autonomous system is a robot that moves on rails, collects infrared and visible images of selected targets, also processes the data and predicts the components lifetime. The robot moves on rails to overcome difficulties found in not paved substations commonly encountered in Brazil. We take advantage of using rails to convey the data by them, minimizing the electromagnetic interference, and at the same time transmitting electrical energy to feed the autonomous system. As part of the quality control process, we compared thermographic inspections made by the robot with inspections made by a trained thermographer using a scientific camera Flir® SC660. The results have shown that the robot achieved satisfactory results, identifying components and measuring temperature accurately. The embodied routine considers the weather changes along the day, providing a standard result of the components thermal response, also gives the uncertainty of temperature measurement, contributing to the quality in the decision making process.

  18. The Effects of Temperature on Political Violence: Global Evidence at the Subnational Level

    PubMed Central

    Bollfrass, Alexander; Shaver, Andrew

    2015-01-01

    A number of studies have demonstrated an empirical relationship between higher ambient temperatures and substate violence, which have been extrapolated to make predictions about the security implications of climate change. This literature rests on the untested assumption that the mechanism behind the temperature-conflict link is that disruption of agricultural production provokes local violence. Using a subnational-level dataset, this paper demonstrates that the relationship: (1) obtains globally, (2) exists at the substate level — provinces that experience positive temperature deviations see increased conflict; and (3) occurs even in regions without significant agricultural production. Diminished local farm output resulting from elevated temperatures is unlikely to account for the entire increase in substate violence. The findings encourage future research to identify additional mechanisms, including the possibility that a substantial portion of the variation is brought about by the well-documented direct effects of temperature on individuals' propensity for violence or through macroeconomic mechanisms such as food price shocks. PMID:25992616

  19. Grizzly Substation Fiber Optics : Environmental Assessment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration.

    1998-02-01

    This notice announces BPA`s decision to construct, operate, and maintain the Grizzly Substation Fiber Optic Project (Project). This Project is part of a continuing effort by BPA to complete a regionwide upgrade of its existing telecommunications system. The US Forest Service and BPA jointly prepared the Grizzly Substation Fiber Optic Project Environmental Assessment (EA) (DOE/EA-1241) evaluating the potential environmental impacts of the Proposed Action, the Underground Installation Alternative, and the No Action Alternative. Based on the analysis in the EA, the US Forest Service and BPA have determined that the Proposed Action is not a major Federal action significantly affectingmore » the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an Environmental Impact Statement (EIS) is not required and BPA is issuing this FONSI. The US Forest Service has separately issued a FONSI and Decision Notice authorizing BPA to construct, operate, and maintain the Project within the Crooked River National Grassland (Grassland).« less

  20. A health examination of railway high-voltage substation workers exposed to ELF electromagnetic fields.

    PubMed

    Baroncelli, P; Battisti, S; Checcucci, A; Comba, P; Grandolfo, M; Serio, A; Vecchia, P

    1986-01-01

    This is a cross-sectional survey on the health conditions of railways workers active in 258 interconnection and conversion substations all over Italy. Measurements performed in both kinds of substations operating at 220 kV have shown that maximum levels of the electric field strength and of the magnetic flux density at 50 Hz are of the order of 5 kV/m and 15 microT, respectively. Three subject groups, differently exposed (1, 10, 20 h/week), and an unexposed control group, for a total number of 627 workers, constitute the population at study. All subjects underwent a general medical examination, laboratory investigations, and a series of selected examinations relative to three systems (nervous, cardiovascular, and haematopoietic) considered at higher risk. No differences have been found between the exposed and the control groups. It is concluded that workers exposed to ELF electromagnetic fields of moderate strength do not show the presence of clear effects on their state of health.

  1. Assessment of the risk of failure of high voltage substations due to environmental conditions and pollution on insulators.

    PubMed

    Castillo Sierra, Rafael; Oviedo-Trespalacios, Oscar; Candelo, John E; Soto, Jose D

    2015-07-01

    Pollution on electrical insulators is one of the greatest causes of failure of substations subjected to high levels of salinity and environmental pollution. Considering leakage current as the main indicator of pollution on insulators, this paper focuses on establishing the effect of the environmental conditions on the risk of failure due to pollution on insulators and determining the significant change in the magnitude of the pollution on the insulators during dry and humid periods. Hierarchical segmentation analysis was used to establish the effect of environmental conditions on the risk of failure due to pollution on insulators. The Kruskal-Wallis test was utilized to determine the significant changes in the magnitude of the pollution due to climate periods. An important result was the discovery that leakage current was more common on insulators during dry periods than humid ones. There was also a higher risk of failure due to pollution during dry periods. During the humid period, various temperatures and wind directions produced a small change in the risk of failure. As a technical result, operators of electrical substations can now identify the cause of an increase in risk of failure due to pollution in the area. The research provides a contribution towards the behaviour of the leakage current under conditions similar to those of the Colombian Caribbean coast and how they affect the risk of failure of the substation due to pollution.

  2. Energy landscape of LeuT from molecular simulations

    NASA Astrophysics Data System (ADS)

    Gur, Mert; Zomot, Elia; Cheng, Mary Hongying; Bahar, Ivet

    2015-12-01

    The bacterial sodium-coupled leucine transporter (LeuT) has been broadly used as a structural model for understanding the structure-dynamics-function of mammalian neurotransmitter transporters as well as other solute carriers that share the same fold (LeuT fold), as the first member of the family crystallographically resolved in multiple states: outward-facing open, outward-facing occluded, and inward-facing open. Yet, a complete picture of the energy landscape of (sub)states visited along the LeuT transport cycle has been elusive. In an attempt to visualize the conformational spectrum of LeuT, we performed extensive simulations of LeuT dimer dynamics in the presence of substrate (Ala or Leu) and co-transported Na+ ions, in explicit membrane and water. We used both conventional molecular dynamics (MD) simulations (with Anton supercomputing machine) and a recently introduced method, collective MD, that takes advantage of collective modes of motions predicted by the anisotropic network model. Free energy landscapes constructed based on ˜40 μs trajectories reveal multiple substates occluded to the extracellular (EC) and/or intracellular (IC) media, varying in the levels of exposure of LeuT to EC or IC vestibules. The IC-facing transmembrane (TM) helical segment TM1a shows an opening, albeit to a smaller extent and in a slightly different direction than that observed in the inward-facing open crystal structure. The study provides insights into the spectrum of conformational substates and paths accessible to LeuT and highlights the differences between Ala- and Leu-bound substates.

  3. Energy landscape of LeuT from molecular simulations.

    PubMed

    Gur, Mert; Zomot, Elia; Cheng, Mary Hongying; Bahar, Ivet

    2015-12-28

    The bacterial sodium-coupled leucine transporter (LeuT) has been broadly used as a structural model for understanding the structure-dynamics-function of mammalian neurotransmitter transporters as well as other solute carriers that share the same fold (LeuT fold), as the first member of the family crystallographically resolved in multiple states: outward-facing open, outward-facing occluded, and inward-facing open. Yet, a complete picture of the energy landscape of (sub)states visited along the LeuT transport cycle has been elusive. In an attempt to visualize the conformational spectrum of LeuT, we performed extensive simulations of LeuT dimer dynamics in the presence of substrate (Ala or Leu) and co-transported Na(+) ions, in explicit membrane and water. We used both conventional molecular dynamics (MD) simulations (with Anton supercomputing machine) and a recently introduced method, collective MD, that takes advantage of collective modes of motions predicted by the anisotropic network model. Free energy landscapes constructed based on ∼40 μs trajectories reveal multiple substates occluded to the extracellular (EC) and/or intracellular (IC) media, varying in the levels of exposure of LeuT to EC or IC vestibules. The IC-facing transmembrane (TM) helical segment TM1a shows an opening, albeit to a smaller extent and in a slightly different direction than that observed in the inward-facing open crystal structure. The study provides insights into the spectrum of conformational substates and paths accessible to LeuT and highlights the differences between Ala- and Leu-bound substates.

  4. Comparison of electric field exposure monitoring instrumentation. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bracken, T.D.

    1985-06-01

    Electric field exposure monitoring instrumentation was compared and evaluated during three days of tests performed in 60-Hz electric fields. A conducting vest exposure meter and a small electric field exposure meter (EFEM) located in a shirt pocket, arm band or hard hat were compared in a series of static and dynamic tests. In some tests, the devices were worn simultaneously without interference to provide separate measures of identical exposure. Tests with stationary subjects wearing the instruments were used to measure the effects of grounding, and to establish the meter response in a standard posture for each subject. Dynamic occupational exposuremore » simulations were used to compare accumulated measurements of exposure between instruments and to compare measurements with predicted exposures. The simulations were based on analysis of the work-related behavior of substation electricians and operators. Electrician's tasks at ground level and in a bucket truck were simulated near an energized test line. A simulated substation inspection was performed in a 230 kV substation. The exposure measurements demonstrated an overall consistency between the meters. The vest demonstrated less intersubject variability and less detailed exposure characterization. Measurements with the shirt pocket EFEM were below those made with the vest and with the EFEM in other locations. Insulation provided by shoe soles appeared to be the largest factor in reducing measured exposures during the substation inspection below those predicted from the unperturbed field. Improvements in meter design and additional measurements are suggested. 11 refs., 20 figs., 28 tabs.« less

  5. Energy landscape of LeuT from molecular simulations

    PubMed Central

    Gur, Mert; Zomot, Elia; Cheng, Mary Hongying; Bahar, Ivet

    2015-01-01

    The bacterial sodium-coupled leucine transporter (LeuT) has been broadly used as a structural model for understanding the structure-dynamics-function of mammalian neurotransmitter transporters as well as other solute carriers that share the same fold (LeuT fold), as the first member of the family crystallographically resolved in multiple states: outward-facing open, outward-facing occluded, and inward-facing open. Yet, a complete picture of the energy landscape of (sub)states visited along the LeuT transport cycle has been elusive. In an attempt to visualize the conformational spectrum of LeuT, we performed extensive simulations of LeuT dimer dynamics in the presence of substrate (Ala or Leu) and co-transported Na+ ions, in explicit membrane and water. We used both conventional molecular dynamics (MD) simulations (with Anton supercomputing machine) and a recently introduced method, collective MD, that takes advantage of collective modes of motions predicted by the anisotropic network model. Free energy landscapes constructed based on ∼40 μs trajectories reveal multiple substates occluded to the extracellular (EC) and/or intracellular (IC) media, varying in the levels of exposure of LeuT to EC or IC vestibules. The IC-facing transmembrane (TM) helical segment TM1a shows an opening, albeit to a smaller extent and in a slightly different direction than that observed in the inward-facing open crystal structure. The study provides insights into the spectrum of conformational substates and paths accessible to LeuT and highlights the differences between Ala- and Leu-bound substates. PMID:26723619

  6. High-precision multi-node clock network distribution.

    PubMed

    Chen, Xing; Cui, Yifan; Lu, Xing; Ci, Cheng; Zhang, Xuesong; Liu, Bo; Wu, Hong; Tang, Tingsong; Shi, Kebin; Zhang, Zhigang

    2017-10-01

    A high precision multi-node clock network for multiple users was built following the precise frequency transmission and time synchronization of 120 km fiber. The network topology adopts a simple star-shaped network structure. The clock signal of a hydrogen maser (synchronized with UTC) was recovered from a 120 km telecommunication fiber link and then was distributed to 4 sub-stations. The fractional frequency instability of all substations is in the level of 10 -15 in a second and the clock offset instability is in sub-ps in root-mean-square average.

  7. Leukaemia and residence near electricity transmission equipment: a case-control study.

    PubMed Central

    Coleman, M. P.; Bell, C. M.; Taylor, H. L.; Primic-Zakelj, M.

    1989-01-01

    A population-based case-control study of leukaemia and residential proximity to electricity supply equipment has been carried out in south-east England. A total of 771 leukaemias was studied, matched for age, sex, year of diagnosis and district of residence to 1,432 controls registered with a solid tumour excluding lymphoma; 231 general population controls aged 18 and over from one part of the study area were also used. The potential for residential exposure to power frequency magnetic fields from power-lines and transformer substations was assessed indirectly from the distance, type and loading of the equipment near each subject's residence. Only 0.6% of subjects lived within 100 m of an overhead power-line, and the risk of leukaemia relative to cancer controls for residence within 100 m was 1.45 (95% confidence interval (CI) 0.54-3.88); within 50 m the relative risk was 2.0 but with a wider confidence interval (95% CI 0.4-9.0). Over 40% of subjects lived within 100 m of a substation, for which the relative risk of leukaemia was 0.99. Residence within 25 m carried a risk of 1.3 (95% CI 0.8-2.0). Weighted exposure indices incorporating measures of the current load carried by the substations did not materially alter these risks estimates. For persons aged less than 18 the relative risk of leukaemia from residence within 50 m of a substation was higher than in adults (PR = 1.5, 95% CI 0.7-3.4). PMID:2486298

  8. Event Detection and Sub-state Discovery from Bio-molecular Simulations Using Higher-Order Statistics: Application To Enzyme Adenylate Kinase

    PubMed Central

    Ramanathan, Arvind; Savol, Andrej J.; Agarwal, Pratul K.; Chennubhotla, Chakra S.

    2012-01-01

    Biomolecular simulations at milli-second and longer timescales can provide vital insights into functional mechanisms. Since post-simulation analyses of such large trajectory data-sets can be a limiting factor in obtaining biological insights, there is an emerging need to identify key dynamical events and relating these events to the biological function online, that is, as simulations are progressing. Recently, we have introduced a novel computational technique, quasi-anharmonic analysis (QAA) (PLoS One 6(1): e15827), for partitioning the conformational landscape into a hierarchy of functionally relevant sub-states. The unique capabilities of QAA are enabled by exploiting anharmonicity in the form of fourth-order statistics for characterizing atomic fluctuations. In this paper, we extend QAA for analyzing long time-scale simulations online. In particular, we present HOST4MD - a higher-order statistical toolbox for molecular dynamics simulations, which (1) identifies key dynamical events as simulations are in progress, (2) explores potential sub-states and (3) identifies conformational transitions that enable the protein to access those sub-states. We demonstrate HOST4MD on micro-second time-scale simulations of the enzyme adenylate kinase in its apo state. HOST4MD identifies several conformational events in these simulations, revealing how the intrinsic coupling between the three sub-domains (LID, CORE and NMP) changes during the simulations. Further, it also identifies an inherent asymmetry in the opening/closing of the two binding sites. We anticipate HOST4MD will provide a powerful and extensible framework for detecting biophysically relevant conformational coordinates from long time-scale simulations. PMID:22733562

  9. Electrical distribution studies for the 200 Area tank farms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisler, J.B.

    1994-08-26

    This is an engineering study providing reliability numbers for various design configurations as well as computer analyses (Captor/Dapper) of the existing distribution system to the 480V side of the unit substations. The objective of the study was to assure the adequacy of the existing electrical system components from the connection at the high voltage supply point through the transformation and distribution equipment to the point where it is reduced to its useful voltage level. It also was to evaluate the reasonableness of proposed solutions of identified deficiencies and recommendations of possible alternate solutions. The electrical utilities are normally considered themore » most vital of the utility systems on a site because all other utility systems depend on electrical power. The system accepts electric power from the external sources, reduces it to a lower voltage, and distributes it to end-use points throughout the site. By classic definition, all utility systems extend to a point 5 feet from the facility perimeter. An exception is made to this definition for the electric utilities at this site. The electrical Utility System ends at the low voltage section of the unit substation, which reduces the voltage from 13.8 kV to 2,400, 480, 277/480 or 120/208 volts. These transformers are located at various distances from existing facilities. The adequacy of the distribution system which transports the power from the main substation to the individual area substations and other load centers is evaluated and factored into the impact of the future load forecast.« less

  10. Molecular dynamics of conformational substates for a simplified protein model

    NASA Astrophysics Data System (ADS)

    Grubmüller, Helmut; Tavan, Paul

    1994-09-01

    Extended molecular dynamics simulations covering a total of 0.232 μs have been carried out on a simplified protein model. Despite its simplified structure, that model exhibits properties similar to those of more realistic protein models. In particular, the model was found to undergo transitions between conformational substates at a time scale of several hundred picoseconds. The computed trajectories turned out to be sufficiently long as to permit a statistical analysis of that conformational dynamics. To check whether effective descriptions neglecting memory effects can reproduce the observed conformational dynamics, two stochastic models were studied. A one-dimensional Langevin effective potential model derived by elimination of subpicosecond dynamical processes could not describe the observed conformational transition rates. In contrast, a simple Markov model describing the transitions between but neglecting dynamical processes within conformational substates reproduced the observed distribution of first passage times. These findings suggest, that protein dynamics generally does not exhibit memory effects at time scales above a few hundred picoseconds, but confirms the existence of memory effects at a picosecond time scale.

  11. Casper to Dave Johnston 230-kV Transmission Line Project: Environmental assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-01-01

    Western proposes to reconstruct the existing Casper-Glendo North 115-kV Transmission Line to 230-kV between a point 1.1 miles northeast of the Pacific Power and Light (Pacific) Casper Substation and the Dave Johnston (DJ) Powerplant near Glenrock, Wyoming. As part of the proposed action, Western proposes to remove the portion of the existing Casper-Glendo South 115-kV Transmission Line between Western's Casper Substation and the intersection with the Casper-Glendo North Transmission Line, about 15 miles east of Casper. The removed portion of the Casper-Glendo North Transmission Line would be rebuilt on steel, single-shaft, structures. The section between the point northeast of themore » Pacific Substation and the intersection with the Casper-Glendo South Transmission Line would be double circuit (230-kV/115-kV). At the intersection of the north and south lines, the new 115-kV section would be tied to the remaining portion of the Casper-Glendo South Line to complete the 115-kV Casper-Glendo circuit. 52 refs.,12 figs., 14 tabs.« less

  12. Historical precedence and technical requirements of biological weapons use : a threat assessment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estes, Daniel P.; Vogel, Kathleen Margaret; Gaudioso, Jennifer Marie

    2004-05-01

    The threat from biological weapons is assessed through both a comparative historical analysis of the patterns of biological weapons use and an assessment of the technological hurdles to proliferation and use that must be overcome. The history of biological weapons is studied to learn how agents have been acquired and what types of states and substate actors have used agents. Substate actors have generally been more willing than states to use pathogens and toxins and they have focused on those agents that are more readily available. There has been an increasing trend of bioterrorism incidents over the past century, butmore » states and substate actors have struggled with one or more of the necessary technological steps. These steps include acquisition of a suitable agent, production of an appropriate quantity and form, and effective deployment. The technological hurdles associated with the steps present a real barrier to producing a high consequence event. However, the ever increasing technological sophistication of society continually lowers the barriers, resulting in a low but increasing probability of a high consequence bioterrorism event.« less

  13. Intercomparison of magnetic field measurements near MV/LV transformer substations: methodological planning and results.

    PubMed

    Violanti, S; Fraschetta, M; Adda, S; Caputo, E

    2009-12-01

    Within the framework of Environmental Agencies system's activities, coordinated by ISPRA (superior institute for environmental protection and research), a comparison among measurements was designed and accomplished, in order to go into depth on the matter of measurement problems and to evaluate magnetic field at power frequencies. These measurements have been taken near medium voltage /low voltage transformer substation. This project was developed with the contribution of several experts who belong to different Regional Agencies. In three of these regions, substations having specific international standard characteristics were chosen; then a measurement and data analysis protocol was arranged. Data analysis showed a good level of coherence among results obtained by different laboratories. However, a range of problems emerged, either during the protocol predisposition and definition of the data analysis procedure or during the execution of measures and data reprocessing, because of the spatial and temporal variability of magnetic field. These problems represent elements of particular interest in determining a correct measurement methodology, whose purpose is the comparison with limits of exposure, attention values and quality targets.

  14. Functional Sub-states by High-pressure Macromolecular Crystallography.

    PubMed

    Dhaussy, Anne-Claire; Girard, Eric

    2015-01-01

    At the molecular level, high-pressure perturbation is of particular interest for biological studies as it allows trapping conformational substates. Moreover, within the context of high-pressure adaptation of deep-sea organisms, it allows to decipher the molecular determinants of piezophily. To provide an accurate description of structural changes produced by pressure in a macromolecular system, developments have been made to adapt macromolecular crystallography to high-pressure studies. The present chapter is an overview of results obtained so far using high-pressure macromolecular techniques, from nucleic acids to virus capsid through monomeric as well as multimeric proteins.

  15. The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gusev, S. I.; Karpov, V. N.; Kiselev, A. N.

    2009-09-15

    The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

  16. Thermally Driven Transport and Relaxation Switching Self-Powered Electromagnetic Energy Conversion.

    PubMed

    Cao, Maosheng; Wang, Xixi; Cao, Wenqiang; Fang, Xiaoyong; Wen, Bo; Yuan, Jie

    2018-06-07

    Electromagnetic energy radiation is becoming a "health-killer" of living bodies, especially around industrial transformer substation and electricity pylon. Harvesting, converting, and storing waste energy for recycling are considered the ideal ways to control electromagnetic radiation. However, heat-generation and temperature-rising with performance degradation remain big problems. Herein, graphene-silica xerogel is dissected hierarchically from functions to "genes," thermally driven relaxation and charge transport, experimentally and theoretically, demonstrating a competitive synergy on energy conversion. A generic approach of "material genes sequencing" is proposed, tactfully transforming the negative effects of heat energy to superiority for switching self-powered and self-circulated electromagnetic devices, beneficial for waste energy harvesting, conversion, and storage. Graphene networks with "well-sequencing genes" (w = P c /P p > 0.2) can serve as nanogenerators, thermally promoting electromagnetic wave absorption by 250%, with broadened bandwidth covering the whole investigated frequency. This finding of nonionic energy conversion opens up an unexpected horizon for converting, storing, and reusing waste electromagnetic energy, providing the most promising way for governing electromagnetic pollution with self-powered and self-circulated electromagnetic devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Development of a plasma sprayed ceramic gas path seal for high pressure turbine application

    NASA Technical Reports Server (NTRS)

    Shiembob, L. T.

    1978-01-01

    Development of the plasma sprayed graded, layered ZRO2/CoCrAlY seal system for gas turbine engine blade tip seal applications up to 1589 K (2400 F) surface temperature was continued. The effect of changing ZRO2/CoCrAlY ratios in the intermediate layers on thermal stresses was evaluated analytically with the goal of identifying the materials combinations which would minimize thermal stresses in the seal system. Three methods of inducing compressive residual stresses in the sprayed seal materials to offset tensile thermal stresses were analyzed. The most promising method, thermal prestraining, was selected based upon potential, feasibility and complexity considerations. The plasma spray equipment was modified to heat, control and monitor the substrate temperature during spraying. Specimens were fabricated and experimentally evaluated to: (1) substantiate the capability of the thermal prestrain method to develop compressive residual stresses in the sprayed structure and (2) define the effect of spraying on a heated substate on abradability, erosion and thermal shock characteristics of the seal system. Thermal stress analysis, including residual stresses and material properties variations, was performed and correlated with thermal shock test results. Seal system performance was assessed and recommendations for further development were made.

  18. Event detection and sub-state discovery from biomolecular simulations using higher-order statistics: application to enzyme adenylate kinase.

    PubMed

    Ramanathan, Arvind; Savol, Andrej J; Agarwal, Pratul K; Chennubhotla, Chakra S

    2012-11-01

    Biomolecular simulations at millisecond and longer time-scales can provide vital insights into functional mechanisms. Because post-simulation analyses of such large trajectory datasets can be a limiting factor in obtaining biological insights, there is an emerging need to identify key dynamical events and relating these events to the biological function online, that is, as simulations are progressing. Recently, we have introduced a novel computational technique, quasi-anharmonic analysis (QAA) (Ramanathan et al., PLoS One 2011;6:e15827), for partitioning the conformational landscape into a hierarchy of functionally relevant sub-states. The unique capabilities of QAA are enabled by exploiting anharmonicity in the form of fourth-order statistics for characterizing atomic fluctuations. In this article, we extend QAA for analyzing long time-scale simulations online. In particular, we present HOST4MD--a higher-order statistical toolbox for molecular dynamics simulations, which (1) identifies key dynamical events as simulations are in progress, (2) explores potential sub-states, and (3) identifies conformational transitions that enable the protein to access those sub-states. We demonstrate HOST4MD on microsecond timescale simulations of the enzyme adenylate kinase in its apo state. HOST4MD identifies several conformational events in these simulations, revealing how the intrinsic coupling between the three subdomains (LID, CORE, and NMP) changes during the simulations. Further, it also identifies an inherent asymmetry in the opening/closing of the two binding sites. We anticipate that HOST4MD will provide a powerful and extensible framework for detecting biophysically relevant conformational coordinates from long time-scale simulations. Copyright © 2012 Wiley Periodicals, Inc.

  19. Conformational flexibility of arginine-82 as source for the heterogeneous and pH-dependent kinetics of the primary proton transfer step in the bacteriorhodopsin photocycle: An electrostatic model

    NASA Astrophysics Data System (ADS)

    Scharnagl, Christina; Fischer, Sighart F.

    1996-11-01

    We use equilibrium thermodynamic concepts to relate protein conformational and protonation substates and their pH-dependent population to kinetic schemes for the rise of the M intermediate in the photocycle of bacteriorhodopsin. Conformational flexibility of arginine R82 is described by a two-state model. The analysis accounts for the electrostatic coupling between its orientation and hydrogen ion titration and presents a structural basis for the linkage between the protonation states of the primary proton acceptor, aspartate D85, and the extracellular release group, glutamate E204. We find that the charge state of D85 is a significant determinant for the orientation of R82. The molecular model predicts the following: the primary proton transfer to D85 can be described by a kinetic scheme with two heterogeneous substates. They control the event with different activation parameters due to the reorientation of R82 away from the chromophore binding site. Their population depends on the external pH and the proton exchange equilibrium between the membrane buried residues and the bulk aqueous solvent. Proton transfer in the physiologic pH range is strongly activated and followed by the reorientation of R82 which shifts the equilibrium toward complete transfer. In the alkaline pH region a different mechanism operates, which involves the increased population of a substate with already reoriented R82 as a consequence of the deprotonation of E204, leading to accelerated proton transfer. Assuming full proton exchange equilibrium with the bulk water on the millisecond time scale leads to an increased population of substates which are non-productive for proton transfer.

  20. Cocaine use in the past year is associated with altitude of residence.

    PubMed

    Fiedler, Kristen K; Kim, Namkug; Kondo, Douglas G; Renshaw, Perry F

    2012-06-01

    Recently, increased rates of suicide in US counties at higher altitudes have been noted. Because of the documented association between cocaine use and suicide, we hypothesized that there would be a correlation between incidence of cocaine use and altitude of residence. Cocaine use data were obtained from the Substate Substance Abuse Estimates from the 1999-2001 National Surveys on Drug Use and Health. Data related to the percentages of people 12 years or older who used cocaine in the past year. Average elevation for US counties was calculated using the Shuttle Radar Topography Mission elevation data set, and subject region elevation was calculated by averaging the weighted elevations of each region's relevant counties. The correlation between elevation of a substate region and incidence of cocaine use in that region was calculated using Pearson correlation coefficients. A significant correlation exists between mean altitude of a substate region and incidence of cocaine use in that region (r = 0.34; P < 0.0001). Regression analysis controlling for age, sex, race, education level, income, unemployment, and population density was performed. Altitude remained a significant factor (P = 0.007), whereas male sex (P = 0.008) and possessing less than a college education (P < 0.0001) were also significant predictors of self-reported cocaine use in the past year. It is important to note that cocaine use was assessed in isolation of other drugs of abuse, an additional confounding variable. This study demonstrates a significant correlation between altitude of substate region of residence and incidence of cocaine use. It is possible that stress response due to hypoxia is responsible; however, this requires further investigation. However, because other substance use was not assessed, specificity of this association is unknown. In addition, this correlation may help explain the increased rate of suicide in areas of higher elevation.

  1. The importance of substate surveillance in detection of geographic oral health inequalities in a small state.

    PubMed

    Anderson, Ludmila; Martin, Nancy R; Flynn, Regina T; Knight, Susan

    2012-01-01

    Considering that 42% of children and adolescents and 91% of dentate adults experience dental caries, oral disease is a public health problem. Although the population's oral health is improving, certain subgroups remain at increased risk for dental disease. To assess the oral health status at the substate level and explore the possibility of geographic oral health inequalities in New Hampshire while building upon existing surveillance data sets. We used the Third Grade Oral Health and NH Behavioral Risk Factor Surveillance System surveys. We ensured the availability of substate level data and compared county/region specific estimates. New Hampshire. Adults and third-grade students in public schools. The prevalence of dental caries, untreated caries, and dental sealants among children; and the insurance status, utilization of dental services, and edentulism among adults. Of the 10 counties, the northernmost Coos County had consistently worse outcomes when compared with other counties. Only 64% of adult Coos County residents reported a dental visit in the past year; of these, 66% reported dental cleaning. Among adults 65 years and older, 29% were edentulous. In comparison with the state overall, these estimates were 76%, 77%, and 19%, respectively. Coos County third-grade students had the highest prevalence of dental caries experience (64% compared with 44% in New Hampshire) and untreated caries (31% compared with 12%), and only 24% had dental sealants (state prevalence is 60%). Overall oral health status in our state is favorable and comparable with the nation, yet significant geographic inequalities exist among children and adults. The oral health status of disparate groups can be improved using tailored interventions such as community water fluoridation or expansion of school-based dental sealant programs. Surveillance at the substate level is an essential part of the planning, targeting, and progress monitoring.

  2. Spontaneous ordering and vortex states of active fluids in circular confinement

    NASA Astrophysics Data System (ADS)

    Theillard, Maxime; Ezhilan, Barath; Saintillan, David

    2015-11-01

    Recent experimental, theoretical and simulation studies have shown that confinement can profoundly affect self-organization in active suspensions leading to striking features such as directed fluid pumping in planar confinement, formation of steady and spontaneous vortices in radial confinement. Motivated by this, we study the dynamics in a suspension of biologically active particles confined in spherical geometries using a mean-field kinetic theory for which we developed a novel numerical solver. In the case of circular confinement, we conduct a systematic exploration of the entire parameter space and distinguish 3 broad states: no-flow, stable vortex and chaotic and several interesting sub-states. Our efficient numerical framework is also employed to study 3D effects and dynamics in more complex geometries.

  3. A quantum leap into the IED age

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, R.C.

    1996-11-01

    The integration of pattern recognition, artificial intelligence and advanced communication technologies in utility substation IED`s (Intelligent Electronic Devices) has opened the door to practical and cost effective automation of power distribution systems. A major driver for the application of these new technologies has been the research directed toward the detection of high-impedance faults. The commercial products which embody these complex detection functions have already expanded to include most of the protection, control, and monitoring required at a utility substation. These new Super-IED`s enable major utility initiatives, such as power quality management, improved public safety, operation and maintenance productivity, and powermore » system automation.« less

  4. Doubly Fed Induction Generator in an Offshore Wind Power Plant Operated at Rated V/Hz: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2012-06-01

    This paper introduces the concept of constant Volt/Hz operation of offshore wind power plants. The deployment of offshore WPPs requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cables, there is a need to use High-Voltage Direct Current transmission, which is economical for transmission distances longer than 50 kilometers. In the concept presented here, the onshore substation is operated at 60 Hz synced with the grid, and the offshore substation is operated at variable frequency and voltage, thus allowing the WPP to be operated at constant Volt/Hz.

  5. Analysis of the 60-Hz power system at KSC: The Orsino substation

    NASA Technical Reports Server (NTRS)

    Kalu, Alex O.

    1989-01-01

    An analysis of the Orsino Substation, a component (50 percent) of the 60-Hertz electric power system at the Kennedy Space Center, is presented. Presented here are separate single-line diagrams of the sixteen feeder circuits to permit easy access to information on the individual feeders for future planning. The load condition of each feeder and load break switch are presented and a heuristic reliability analysis of the system is performed. Information is given about the system fashion useful for decision making purposes. The beauty of it is in the simplified manner by which information about the system can be obtained.

  6. Study on the Transient Process of 500kV Substations Secondary Equipment

    NASA Astrophysics Data System (ADS)

    Li, Hongbo; Li, Pei; Zhang, Yanyan; Niu, Lin; Gao, Nannan; Si, Tailong; Guo, Jiadong; Xu, Min-min; Li, Guofeng; Guo, Liangfeng

    2017-05-01

    By analyzing on the reason of the lightning accident occur in the substation, the way of lightning incoming surge invading the secondary system is summarized. The interference source acts on the secondary system through various coupling paths. It mainly consists of four ways: the conductance coupling mode, the Capacitive Coupling Mode, the inductive coupling mode, The Radiation Interference Model. Then simulated the way with the program-ATP. At last, from the three aspects of low-voltage power supply system, the impact potential distribution of grounding grid, the secondary system and the computer system. The lightning protection measures is put forward.

  7. An Economic Analysis and Approach for Health Care Preparedness in a Substate Region.

    PubMed

    Stryckman, Benoit; Grace, Thomas L; Schwarz, Peter; Marcozzi, David

    2015-08-01

    To demonstrate the application of economics to health care preparedness by estimating the financial return on investment in a substate regional emergency response team and to develop a financial model aimed at sustaining community-level disaster readiness. Economic evaluation methods were applied to the experience of a regional Pennsylvania response capability. A cost-benefit analysis was performed by using information on funding of the response team and 17 real-world events the team responded to between 2008 and 2013. By use of the results of the cost-benefit analysis as well as information on the response team's catchment area, a risk-based insurance-like membership model was built. The cost-benefit analysis showed a positive return after 6 years of investment in the regional emergency response team. Financial modeling allowed for the calculation of premiums for 2 types of providers within the emergency response team's catchment area: hospitals and long-term care facilities. The analysis indicated that preparedness activities have a positive return on their investment in this substate region. By applying economic principles, communities can estimate their return on investment to make better business decisions in an effort to increase the sustainability of emergency preparedness programs at the regional level.

  8. Progress of gas-insulated transformers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Togawa, Y.; Ikeda, M.; Toda, K.

    The world`s first transformer was manufactured at Ganz in Hungary in 1885. Two years later in 1887 patents applications were made for about oil immersed transformers in the US. Since then, oil immersed types have predominated for medium- and large-capacity transformers, which are now giving way to gas insulated transformers in some areas. Behind such trends are plans to construct substations inside buildings or underground, because of the difficulty in acquiring land for substations in large cities where power demand is concentrated. Requirements are protection against accidents, compactness and overall economy. Total gas insulated substations combining GIS units and gasmore » insulated transformers these needs. Demand for gas insulated transformers has been increasing rapidly, particularly in Japan and Hong Kong. First, relatively small-capacity models below 20--30 MVA were put into practical use and today 275 kV, 300 MVa models are in use and 500kV, 1,500 MVA models are coming into use. Engineering is progressing very rapidly in these areas. This paper describes the design techniques and important maintenance techniques for the latest gas insulated transformers from 5,000 kVA to 300 MVA.« less

  9. IEA Wind Task 26: Offshore Wind Farm Baseline Documentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smart, Gavin; Smith, Aaron; Warner, Ethan

    This document has been produced to provide the definition and rationale for the Baseline Offshore Wind Farm established within IEA Wind Task 26--Cost of Wind Energy. The Baseline has been developed to provide a common starting point for country comparisons and sensitivity analysis on key offshore wind cost and value drivers. The baseline project reflects an approximate average of the characteristics of projects installed between 2012 and 2014, with the project life assumed to be 20 years. The baseline wind farm is located 40 kilometres (km) from construction and operations and maintenance (O&M) ports and from export cable landfall. Themore » wind farm consists of 100 4-megawatt (MW) wind turbines mounted on monopile foundations in an average water depth of 25 metres (m), connected by 33-kilovolt (kV) inter-array cables. The arrays are connected to a single offshore substation (33kV/220kV) mounted on a jacket foundation, with the substation connected via a single 220kV export cable to an onshore substation, 10km from landfall. The wind farm employs a port-based O&M strategy using crew-transfer vessels.« less

  10. Occupational exposure to electric and magnetic fields during work tasks at 110 kV substations in the Tampere region.

    PubMed

    Korpinen, Leena H; Pääkkönen, Rauno J

    2010-04-01

    The occupational exposure to electric and magnetic fields during various work tasks at seven 110 kV substations in Finland's Tampere region was studied. The aim was to investigate if the action values (10 kV/m for the E-field and 500 microT for the B-field) of the EU Directive 2004/40/EC were exceeded. Electric and magnetic fields were measured during the following work tasks: (1) walking or operating devices on the ground; (2) working from a service platform; (3) working around the power transformer on the ground or using a ladder; and (4) changing a bulb from a man hoist. In work task 2 "working from a service platform" the measured electric field (maximum value 16.6 kV/m) exceeded 10 kV/m in three cases. In the future it is important to study if the limit value (10 mA/m(2)) of Directive 2004/40/EC is exceeded at 110 kV substations. The occupational 500 microT action value of the magnetic flux density field (B-field) was not exceeded in any working situation.

  11. Integrated, Automated Distributed Generation Technologies Demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Kevin

    2014-09-01

    The purpose of the NETL Project was to develop a diverse combination of distributed renewable generation technologies and controls and demonstrate how the renewable generation could help manage substation peak demand at the ATK Promontory plant site. The Promontory plant site is located in the northwestern Utah desert approximately 25 miles west of Brigham City, Utah. The plant encompasses 20,000 acres and has over 500 buildings. The ATK Promontory plant primarily manufactures solid propellant rocket motors for both commercial and government launch systems. The original project objectives focused on distributed generation; a 100 kW (kilowatt) wind turbine, a 100 kWmore » new technology waste heat generation unit, a 500 kW energy storage system, and an intelligent system-wide automation system to monitor and control the renewable energy devices then release the stored energy during the peak demand time. The original goal was to reduce peak demand from the electrical utility company, Rocky Mountain Power (RMP), by 3.4%. For a period of time we also sought to integrate our energy storage requirements with a flywheel storage system (500 kW) proposed for the Promontory/RMP Substation. Ultimately the flywheel storage system could not meet our project timetable, so the storage requirement was switched to a battery storage system (300 kW.) A secondary objective was to design/install a bi-directional customer/utility gateway application for real-time visibility and communications between RMP, and ATK. This objective was not achieved because of technical issues with RMP, ATK Information Technology Department’s stringent requirements based on being a rocket motor manufacturing facility, and budget constraints. Of the original objectives, the following were achieved: • Installation of a 100 kW wind turbine. • Installation of a 300 kW battery storage system. • Integrated control system installed to offset electrical demand by releasing stored energy from renewable sources during peak hours of the day. Control system also monitors the wind turbine and battery storage system health, power output, and issues critical alarms. Of the original objectives, the following were not achieved: • 100 kW new technology waste heat generation unit. • Bi-directional customer/utility gateway for real time visibility and communications between RMP and ATK. • 3.4% reduction in peak demand. 1.7% reduction in peak demand was realized instead.« less

  12. Atomistic details of the disordered states of KID and pKID. Implications in coupled binding and folding.

    PubMed

    Ganguly, Debabani; Chen, Jianhan

    2009-04-15

    Intrinsically disordered proteins (IDPs) are a newly recognized class of functional proteins for which a lack of stable tertiary fold is required for function. Because of the heterogeneous and dynamical nature, molecular modeling is necessary to provide the missing details of disordered states of IDP that are crucial for understanding their functions. In particular, generalized Born (GB) implicit solvent, combined with replica exchange (REX), might offer an optimal balance between accuracy and efficiency for modeling IDPs. We carried out extensive REX simulations in an optimized GB force field to characterize the disordered states of a regulatory IDP, KID domain of transcription factor CREB, and its phosphorylated form, pKID. The results revealed that both KID and pKID, though highly disordered on the tertiary level, are compact and mainly occupy a small number of helical substates. Interestingly, although phosphorylation of KID Ser133 leads only to marginal changes in average helicities on the ensemble level, underlying conformational substates differ significantly. In particular, pSer133 appears to restrict the accessible conformational space of the loop region and thus reduces the entropic cost of KID folding upon binding to the KIX domain of CREB-binding protein. Such an expanded role of phosphorylation in the KID:KIX recognition was not previously recognized because of a lack of substantial conformational changes on the ensemble level and inaccessibility of the structural details from experiments. The results also suggest that an implicit solvent-based modeling framework, despite various existing limitations, might be feasible for accurate atomistic simulation of small IDPs in general.

  13. Epidermal cell-shape regulation and subpopulation kinetics during butyrate-induced terminal maturation of normal and SV40-transformed human keratinocytes: epithelial models of differentiation therapy.

    PubMed

    Staiano-Coico, L; Steinberg, M; Higgins, P J

    1990-10-15

    Recent data indicate that malignant human epidermal cells may be appropriate targets for sodium butyrate (NaB)-mediated differentiation therapy. The response of pre- and post-crisis populations of SV40-transformed human keratinocytes (SVKs) to this differentiation-inducing agent was assessed, therefore, within the framework of NaB-directed normal human keratinocyte (NHK) maturation. NaB augmented cornified envelope (CE) production in NHK and pre-crisis SVK cultures; the time-course and efficiency of induced maturation were similar in the 2 cell systems. In NHKs, the percentage of amplifying ("B" substate) cells decreased with time in NaB correlating with increases in both "C" stage keratinocytes and CEs. The latter formed over one or 2 layers of nucleated basal-like cells. Inductions were accompanied by immediate cell cycle blocks (in both the G1 and G2/M phases), reorganization within the actin cytoskeleton, and transient early increases in cellular actin content. Increased NHK and pre-crisis SVK cytoskeletal-associated actin reached a maximum approximately 48 hr after NaB addition and preceded development of CEs. The CE precursors, thus, probably reside in the "B" substate. Post-crisis SVKs, in contrast, were refractive to NaB-induced terminal maturation or cell-cycle perturbation, failed to initiate actin filament rearrangements, and retained a basal cell-like phenotype. Stable transformation of human SVKs in post-crisis phase, therefore, appears to be associated with loss of maturation "competence" within the "B" keratinocyte subpopulation.

  14. Run-Curve Design for Energy Saving Operation in a Modern DC-Electrification

    NASA Astrophysics Data System (ADS)

    Koseki, Takafumi; Noda, Takashi

    Mechanical brakes are often used by electric trains. These brakes have a few problems like response speed, coefficient of friction, maintenance cost and so on. As a result, methods for actively using regenerative brakes are required. In this paper, we propose the useful pure electric braking, which would involve ordinary brakes by only regenerative brakes without any mechanical brakes at high speed. Benefits of our proposal include a DC-electrification system with regenerative substations that can return powers to the commercial power system and a train that can use the full regenerative braking force. We furthermore evaluate the effects on running time and energies saved by regenerative substations in the proposed method.

  15. A survey of industry practices regarding shielding of substations against direct lightning strokes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mousa, A.M.; Wehling, R.J.

    1993-01-01

    A survey of industry practices regarding shielding of substations against direct lightning strokes is presented and analyzed. The survey is based on responses from 114 companies including consultants and utilities both from within and from outside North America. The survey identifies the shielding design methods in use, the factors affecting the selection of a shielding method, the shielding design criteria and the governing factors, the performance of the different shielding methods and miscellaneous related aspects. The survey revealed a large number (35) of shielding failure incidents; 34 of which occurred in systems designed using either the fixed shielding angle methodmore » or Wagner's 1942 method.« less

  16. Development of Protection and Control Unit for Distribution Substation

    NASA Astrophysics Data System (ADS)

    Iguchi, Fumiaki; Hayashi, Hideyuki; Takeuchi, Motohiro; Kido, Mitsuyasu; Kobayashi, Takashi; Yanaoka, Atsushi

    The Recently, electronics and IT technologies have been rapidly innovated and have been introduced to power system protection & control system to achieve high reliability, maintainability and more functionality. Concerning the distribution substation application, digital relays have been applied for more than 10 years. Because of a number of electronic devices used for it, product cost becomes higher. Also, products installed during the past high-growth period will be at the end of lifetime and will be replaced. Therefore, replacing market is expected to grow and the reduction of cost is demanded. Considering above mentioned background, second generation digital protection and control unit as a successor is designed to have following concepts. Functional integration based on advanced digital technologies, Ethernet LAN based indoor communication network, cost reduction and downsizing. Pondering above concepts, integration of protection and control function is adopted in contrary to the functional segregation applied to the previous system in order to achieve one-unit concept. Also the adoption of Ethernet LAN for inter-unit communication is objective. This report shows the development of second-generation digital relay for distribution substation, which is equipped with control function and Ethernet LAN by reducing the size of auxiliary transformer unit and the same size as previous product is realized.

  17. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines.

    PubMed

    Tourab, Wafa; Babouri, Abdesselam

    2016-06-01

    This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  18. Heterogeneous Wireless Networks for Smart Grid Distribution Systems: Advantages and Limitations.

    PubMed

    Khalifa, Tarek; Abdrabou, Atef; Shaban, Khaled; Gaouda, A M

    2018-05-11

    Supporting a conventional power grid with advanced communication capabilities is a cornerstone to transferring it to a smart grid. A reliable communication infrastructure with a high throughput can lay the foundation towards the ultimate objective of a fully automated power grid with self-healing capabilities. In order to realize this objective, the communication infrastructure of a power distribution network needs to be extended to cover all substations including medium/low voltage ones. This shall enable information exchange among substations for a variety of system automation purposes with a low latency that suits time critical applications. This paper proposes the integration of two heterogeneous wireless technologies (such as WiFi and cellular 3G/4G) to provide reliable and fast communication among primary and secondary distribution substations. This integration allows the transmission of different data packets (not packet replicas) over two radio interfaces, making these interfaces act like a one data pipe. Thus, the paper investigates the applicability and effectiveness of employing heterogeneous wireless networks (HWNs) in achieving the desired reliability and timeliness requirements of future smart grids. We study the performance of HWNs in a realistic scenario under different data transfer loads and packet loss ratios. Our findings reveal that HWNs can be a viable data transfer option for smart grids.

  19. Heterogeneous Wireless Networks for Smart Grid Distribution Systems: Advantages and Limitations

    PubMed Central

    Khalifa, Tarek; Abdrabou, Atef; Gaouda, A. M.

    2018-01-01

    Supporting a conventional power grid with advanced communication capabilities is a cornerstone to transferring it to a smart grid. A reliable communication infrastructure with a high throughput can lay the foundation towards the ultimate objective of a fully automated power grid with self-healing capabilities. In order to realize this objective, the communication infrastructure of a power distribution network needs to be extended to cover all substations including medium/low voltage ones. This shall enable information exchange among substations for a variety of system automation purposes with a low latency that suits time critical applications. This paper proposes the integration of two heterogeneous wireless technologies (such as WiFi and cellular 3G/4G) to provide reliable and fast communication among primary and secondary distribution substations. This integration allows the transmission of different data packets (not packet replicas) over two radio interfaces, making these interfaces act like a one data pipe. Thus, the paper investigates the applicability and effectiveness of employing heterogeneous wireless networks (HWNs) in achieving the desired reliability and timeliness requirements of future smart grids. We study the performance of HWNs in a realistic scenario under different data transfer loads and packet loss ratios. Our findings reveal that HWNs can be a viable data transfer option for smart grids. PMID:29751633

  20. Draft Supplement to the Environmental Statement Fiscal Year 1975 Proposed Program : Facility Location Evaluation for San Juan Island Service : Decatur Land Line and East Lopez Island Substation Study Area 74-7.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration.

    1974-03-08

    Proposed construction of a 1.7-mile 34.5-kV double-circuit transmission line crossing Decatur Island from east to west. The new line would replace 0.7 of a mile of an existing BPA 24.5-kV line and would then parallel and existing 24.5-kV line for a distance of 1.0 mile. The proposal also requires the construction of a new substation to be located on the eastern side of Lopez Island, Washington. The additional easement required for the proposed transmission line would remove about 1.1 acres of forestland from timber production diverting it to nonforest uses compatable with the transmission line right-of-way. Depending upon the actualmore » site location the Lopez Island Substation could remove from 1 to 3.2 acres of forestland and 2 acres of pastureland from production. Disturbance of game in the immediate vicintiy of the transmission facilities will occur during construction, as will some soil erosion primarily during and immediately after construction, siltation in nearby streams, disturbance of nearby residents from noise and dust during construction, and some degradation of AM reception immediately adjacent to the right-of-way. 7 figs.« less

  1. Proposed Columbia Wind Farm No. 1 : Final Environmental Impact Statement, Joint NEPA/SEPA.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration; Klickitat County

    1995-09-01

    CARES proposes to construct and operate the 25 megawatt Columbia Wind Farm No. 1 (Project) in the Columbia Hills area of Klickitat County, Washington known as Juniper Point. Wind is not a constant resource and based on the site wind measurement data, it is estimated that the Project would generate approximately 7 average annual MWs of electricity. BPA proposes to purchase the electricity generated by the Project. CARES would execute a contractual agreement with a wind developer, to install approximately 91 wind turbines and associated facilities to generate electricity. The Project`s construction and operation would include: install concrete pier foundationsmore » for each wind turbine; install 91 model AWT-26 wind turbines using 43 m high guyed tubular towers on the pier foundations; construct a new 115/24-kv substation; construct a 149 m{sup 2} steel operations and maintenance building; install 25 pad mount transformers along the turbine access roads; install 4.0 km of underground 24 kv power collection lines to collect power from individual turbines to the end of turbine strings; install 1.2 km of underground communication and transmission lines from each turbine to a pad mount transformer; install 5.6 km of 24 kv wood pole transmission lines to deliver electricity from the pad mount transformers to the Project substation; install 3.2 km of 115 kv wood pole transmission lines to deliver electricity from the Project substation to the Public Utility District No. 1 of Klickitat County(PUD)115 kv Goldendale line; interconnect with the BPA transmission system through the Goldendale line and Goldendale substation owned by the PUD; reconstruct, upgrade, and maintain 8.0 km of existing roads; construct and maintain 6.4 km of new graveled roads along the turbine strings and to individual turbines; and install meteorological towers guyed with rebar anchors on the Project site.« less

  2. An applied methodology for assessment of the sustainability of biomass district heating systems

    NASA Astrophysics Data System (ADS)

    Vallios, Ioannis; Tsoutsos, Theocharis; Papadakis, George

    2016-03-01

    In order to maximise the share of biomass in the energy supplying system, the designers should adopt the appropriate changes to the traditional systems and become more familiar with the design details of the biomass heating systems. The aim of this study is to present the development of methodology and its associated implementation in software that is useful for the design of biomass thermal conversion systems linked with district heating (DH) systems, taking into consideration the types of building structures and urban settlement layout around the plant. The methodology is based on a completely parametric logic, providing an impact assessment of variations in one or more technical and/or economic parameters and thus, facilitating a quick conclusion on the viability of this particular energy system. The essential energy parameters are presented and discussed for the design of biomass power and heat production system which are in connection with DH network, as well as for its environmental and economic evaluation (i.e. selectivity and viability of the relevant investment). Emphasis has been placed upon the technical parameters of biomass logistics, energy system's design, the economic details of the selected technology (integrated cogeneration combined cycle or direct combustion boiler), the DH network and peripheral equipment (thermal substations) and the greenhouse gas emissions. The purpose of this implementation is the assessment of the pertinent investment financial viability taking into account the available biomass feedstock, the economical and market conditions, and the capital/operating costs. As long as biomass resources (forest wood and cultivation products) are available and close to the settlement, disposal and transportation costs of biomass, remain low assuring the sustainability of such energy systems.

  3. Research of waste heat energy efficiency for absorption heat pump recycling thermal power plant circulating water

    NASA Astrophysics Data System (ADS)

    Zhang, Li; Zhang, Yu; Zhou, Liansheng; E, Zhijun; Wang, Kun; Wang, Ziyue; Li, Guohao; Qu, Bin

    2018-02-01

    The waste heat energy efficiency for absorption heat pump recycling thermal power plant circulating water has been analyzed. After the operation of heat pump, the influences on power generation and heat generation of unit were taken into account. In the light of the characteristics of heat pump in different operation stages, the energy efficiency of heat pump was evaluated comprehensively on both sides of benefits belonging to electricity and benefits belonging to heat, which adopted the method of contrast test. Thus, the reference of energy efficiency for same type projects was provided.

  4. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-137- Chemawa-Salem 1&2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherer, Brett M.

    Vegetation Management for the Chemawa-Salem #1 115 kV and #2 230 kV transmission lines from Chemawa Substation to Salem Substation. BPA proposes to remove unwanted vegetation along the right-of-way, access roads, switch platforms, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have lowgrowing plant communities along the rights-of-way to control the development of potentiallymore » threatening vegetation.« less

  5. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-141- Salem Albany #2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barndt, Shawn L.

    Vegetation Management for the Salem Albany #2 115 kV transmission line from Salem Substation to Albany Substation. BPA proposes to remove unwanted vegetation along the right-of-way, access roads, switch platforms, microwave beam paths, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentiallymore » threatening vegetation.« less

  6. Type B investigation of electrical fault in 351 Substation, December 4, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debban, H.L.; Shearer, C.A.; Boger, R.M.

    1995-02-01

    On December 4, 1994, at 2132:10 hours, an electrical failure of a cable-tapping splice resulted in a fire in the 300 Area of the DOE Hanford Site. The fire occurred in the yard of Substation 351 in electrical Vault R122V, where the cable-tapping splice was located. The fire incinerated all cables passing to and through the vault causing them to fail. The failure of the cables resulted in a power outage to twenty customers in the 300 Area. The vault was electrically isolated, and power was restored to the electrical distribution system at 2311 hours. This report contains the accidentmore » scenario, accident analysis, direct cause and root and contributing causes.« less

  7. Effect of the load size on the efficiency of microwave heating under stop flow and continuous flow conditions.

    PubMed

    Patil, Narendra G; Rebrov, Evgeny V; Eränen, Kari; Benaskar, Faysal; Meuldijk, Jan; Mikkola, Jyri-Pekka; Hessel, Volker; Hulshof, Lumbertus A; Murzin, Dmitry Yu; Schouten, Jaap C

    2012-01-01

    A novel heating efficiency analysis of the microwave heated stop-flow (i.e. stagnant liquid) and continuous-flow reactors has been presented. The thermal losses to the surrounding air by natural convection have been taken into account for heating efficiency calculation of the microwave heating process. The effect of the load diameter in the range of 4-29 mm on the heating efficiency of ethylene glycol was studied in a single mode microwave cavity under continuous flow and stop-flow conditions. The variation of the microwave absorbing properties of the load with temperature was estimated. Under stop-flow conditions, the heating efficiency depends on the load diameter. The highest heating efficiency has been observed at the load diameter close to the half wavelength of the electromagnetic field in the corresponding medium. Under continuous-flow conditions, the heating efficiency increased linearly. However, microwave leakage above the propagation diameter restricted further experimentation at higher load diameters. Contrary to the stop-flow conditions, the load temperature did not raise monotonously from the inlet to outlet under continuous-flow conditions. This was due to the combined effect of lagging convective heat fluxes in comparison to volumetric heating. This severely disturbs the uniformity of the electromagnetic field in the axial direction and creates areas of high and low field intensity along the load Length decreasing the heating efficiency as compared to stop-flow conditions.

  8. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  9. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  10. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  11. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  12. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  13. 36 CFR 292.21 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .../forest/grazing uses may also consist of uses related to and in furtherance of the protection of... transmission line systems, substations, commercial radio transmitters, relays or repeater stations, antennas...

  14. 36 CFR 292.21 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .../forest/grazing uses may also consist of uses related to and in furtherance of the protection of... transmission line systems, substations, commercial radio transmitters, relays or repeater stations, antennas...

  15. Architecture and Methods for Substation SCADA Cybersecurity: Best Practices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albunashee, Hamdi; Al Sarray, Muthanna; McCann, Roy

    There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize themore » R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.« less

  16. Effects of the distribution density of a biomass combined heat and power plant network on heat utilisation efficiency in village-town systems.

    PubMed

    Zhang, Yifei; Kang, Jian

    2017-11-01

    The building of biomass combined heat and power (CHP) plants is an effective means of developing biomass energy because they can satisfy demands for winter heating and electricity consumption. The purpose of this study was to analyse the effect of the distribution density of a biomass CHP plant network on heat utilisation efficiency in a village-town system. The distribution density is determined based on the heat transmission threshold, and the heat utilisation efficiency is determined based on the heat demand distribution, heat output efficiency, and heat transmission loss. The objective of this study was to ascertain the optimal value for the heat transmission threshold using a multi-scheme comparison based on an analysis of these factors. To this end, a model of a biomass CHP plant network was built using geographic information system tools to simulate and generate three planning schemes with different heat transmission thresholds (6, 8, and 10 km) according to the heat demand distribution. The heat utilisation efficiencies of these planning schemes were then compared by calculating the gross power, heat output efficiency, and heat transmission loss of the biomass CHP plant for each scenario. This multi-scheme comparison yielded the following results: when the heat transmission threshold was low, the distribution density of the biomass CHP plant network was high and the biomass CHP plants tended to be relatively small. In contrast, when the heat transmission threshold was high, the distribution density of the network was low and the biomass CHP plants tended to be relatively large. When the heat transmission threshold was 8 km, the distribution density of the biomass CHP plant network was optimised for efficient heat utilisation. To promote the development of renewable energy sources, a planning scheme for a biomass CHP plant network that maximises heat utilisation efficiency can be obtained using the optimal heat transmission threshold and the nonlinearity coefficient for local roads. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. QAARM: quasi-anharmonic autoregressive model reveals molecular recognition pathways in ubiquitin

    PubMed Central

    Savol, Andrej J.; Burger, Virginia M.; Agarwal, Pratul K.; Ramanathan, Arvind; Chennubhotla, Chakra S.

    2011-01-01

    Motivation: Molecular dynamics (MD) simulations have dramatically improved the atomistic understanding of protein motions, energetics and function. These growing datasets have necessitated a corresponding emphasis on trajectory analysis methods for characterizing simulation data, particularly since functional protein motions and transitions are often rare and/or intricate events. Observing that such events give rise to long-tailed spatial distributions, we recently developed a higher-order statistics based dimensionality reduction method, called quasi-anharmonic analysis (QAA), for identifying biophysically-relevant reaction coordinates and substates within MD simulations. Further characterization of conformation space should consider the temporal dynamics specific to each identified substate. Results: Our model uses hierarchical clustering to learn energetically coherent substates and dynamic modes of motion from a 0.5 μs ubiqutin simulation. Autoregressive (AR) modeling within and between states enables a compact and generative description of the conformational landscape as it relates to functional transitions between binding poses. Lacking a predictive component, QAA is extended here within a general AR model appreciative of the trajectory's temporal dependencies and the specific, local dynamics accessible to a protein within identified energy wells. These metastable states and their transition rates are extracted within a QAA-derived subspace using hierarchical Markov clustering to provide parameter sets for the second-order AR model. We show the learned model can be extrapolated to synthesize trajectories of arbitrary length. Contact: ramanathana@ornl.gov; chakracs@pitt.edu PMID:21685101

  18. Molecular dynamics simulation of nitric oxide in myoglobin

    USGS Publications Warehouse

    Lee, Myung Won; Meuwly, Markus

    2012-01-01

    The infrared (IR) spectroscopy and ligand migration of photodissociated nitric oxide (NO) in and around the active sites in myoglobin (Mb) are investigated. A distributed multipolar model for open-shell systems is developed and used, which allows one to realistically describe the charge distribution around the diatomic probe molecule. The IR spectra were computed from the trajectories for two conformational substates at various temperatures. The lines are narrow (width of 3–7 cm–1 at 20–100 K), in agreement with the experimental observations where they have widths of 4–5 cm–1 at 4 K. It is found that within one conformational substate (B or C) the splitting of the spectrum can be correctly described compared with recent experiments. Similar to photodissociated CO in Mb, additional substates exist for NO in Mb, which are separated by barriers below 1 kcal/mol. Contrary to full quantum mechanical calculations, however, the force field and mixed QM/MM simulations do not correctly describe the relative shifts between the B- and C-states relative to gas-phase NO. Free energy simulations establish that NO preferably localizes in the distal site and the barrier for migration to the neighboring Xe4 pocket is ΔGB→C = 1.7–2.0 kcal/mol. The reverse barrier is ΔGB←C = 0.7 kcal/mol, which agrees well with the experimental value of 0.7 kcal/mol, estimated from kinetic data.

  19. 40 CFR 98.438 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... substations, circuit breakers, other switchgear, gas-insulated lines, or power transformers. Fluorinated GHG... transformers containing a fluorinated GHG prior to sale or distribution, or offer for sale or distribution in...

  20. 40 CFR 98.438 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... substations, circuit breakers, other switchgear, gas-insulated lines, or power transformers. Fluorinated GHG... transformers containing a fluorinated GHG prior to sale or distribution, or offer for sale or distribution in...

  1. 40 CFR 98.438 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... substations, circuit breakers, other switchgear, gas-insulated lines, or power transformers. Fluorinated GHG... transformers containing a fluorinated GHG prior to sale or distribution, or offer for sale or distribution in...

  2. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  3. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  4. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  5. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  6. Dualism of the 5f electrons of the ferromagnetic superconductor UGe2 as seen in magnetic, transport, and specific-heat data

    NASA Astrophysics Data System (ADS)

    Troć, R.; Gajek, Z.; Pikul, A.

    2012-12-01

    Single-crystalline UGe2 was investigated by means of magnetic susceptibility, magnetization, electrical resistivity, magnetoresistivity, and specific-heat measurements, all carried out in wide temperature and magnetic-field ranges. An analysis of the obtained data points out the dual behavior of the 5f electrons in this compound, i.e., possessing simultaneously local and itinerant characters in two substates. The magnetic and thermal characteristics of the compound were modeled using the effective crystal field (CF) in the intermediate coupling scheme and initial parameters obtained in the angular overlap model. Various configurations of the localized 5fn (n = 1, 2, and 3) electrons on the uranium ion have been probed. The best results were obtained for the 5f2 (U4+) configuration. The CF parameters obtained in the paramagnetic region allowed us to reproduce satisfactorily the experimental findings in the whole temperature range including also the magnitude of the ordered magnetic moment of uranium at low temperature. The electrical resistivity data after subtraction of the phonon contribution reveal the presence of a Kondo-like interaction in UGe2 supporting the idea of partial localization of the 5f electrons in UGe2. On the other hand, magnetoresistivity and an excess of specific heat originated from the hybridized (itinerant) part of 5f states, apparent around the characteristic temperature T*, give a distinct signature for the presence of the coupled charge-density wave and spin-density wave fluctuations over all the ferromagnetic region with a maximum at T*, postulated earlier in the literature.

  7. 30 CFR 75.380 - Escapeways; bituminous and lignite mines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Underground transformer stations, battery charging stations, substations, and rectifiers except— (A) Where... rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid...

  8. Variation in Vaccination Data Available at School Entry Across the United States.

    PubMed

    Leslie, Timothy F; Street, Erica J; Delamater, Paul L; Yang, Y Tony; Jacobsen, Kathryn H

    2016-12-01

    To compile substate-level data on US school-age children's vaccination rates. For states that did not have suitable data online, in 2015 we submitted information requests to the state health department and followed up with the state's Freedom of Information Act when necessary. The accessibility, scale, and types of vaccination data varied considerably. Whereas 26 states provided data online, 14 released data only after a Freedom of Information Act request. School or school-district data were available for 24 states, 19 at the county level, 2 at the health department level, and 6 provided no substate-level data. Effective vaccination policy requires a robust understanding of vaccination behavior. Some states make it difficult to access data or provide low-resolution data of limited value for identifying vaccination behavior.

  9. Characterization of the conformational equilibrium between the two major substates of RNase A using NMR chemical shifts.

    PubMed

    Camilloni, Carlo; Robustelli, Paul; De Simone, Alfonso; Cavalli, Andrea; Vendruscolo, Michele

    2012-03-07

    Following the recognition that NMR chemical shifts can be used for protein structure determination, rapid advances have recently been made in methods for extending this strategy for proteins and protein complexes of increasing size and complexity. A remaining major challenge is to develop approaches to exploit the information contained in the chemical shifts about conformational fluctuations in native states of proteins. In this work we show that it is possible to determine an ensemble of conformations representing the free energy surface of RNase A using chemical shifts as replica-averaged restraints in molecular dynamics simulations. Analysis of this surface indicates that chemical shifts can be used to characterize the conformational equilibrium between the two major substates of this protein. © 2012 American Chemical Society

  10. Experience in the installation of a microprocessor system for controlling converter units of the Vyborg substation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gusakovskii, K. B.; Zmaznov, E. Yu.; Katantsev, S. V.

    The experience in the installation of modern digital systems for controlling converter units at the Vyborg converter substation on the basis of advanced microprocessor devices is considered. It is shown that debugging of a control and protection system on mathematical and physical models does not guarantee optimum control of actual converter devices. Examples of advancing the control and protection system are described, the necessity for which has become obvious in tests of actual equipment. Comparison of oscillograms of processes before optimization of the control system and after its optimization and adjustment shows that the digital control system makes it possiblemore » to improve substantially the algorithms of control and protection in the short term and without changing the hardware component.« less

  11. View southeast of main supervisory board showing panels 3 through ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View southeast of main supervisory board showing panels 3 through 11; panel 3 at far left contains meters for monitoring power in the system; panel 4 contains controls for controlling heaters to keep track twitches free of ice and snow; panels 5, 6, and 7 date to the 1935 installation and control the catenary in the area of the station yard. These work on 120 volts direct current; panel 8 contains circuit breakers (rupture switches) which control power to individual tracks in the station area; panels 9 and 10 house controls for the West Philadelphia sub-station; panel 11 controls sub-station 13 in South Wilmington Delaware and miscellaneous meters - Thirtieth Street Station, Power Director Center, Thirtieth & Market Streets in Amtrak Railroad Station, Philadelphia, Philadelphia County, PA

  12. Holographic heat engine within the framework of massive gravity

    NASA Astrophysics Data System (ADS)

    Mo, Jie-Xiong; Li, Gu-Qiang

    2018-05-01

    Heat engine models are constructed within the framework of massive gravity in this paper. For the four-dimensional charged black holes in massive gravity, it is shown that the existence of graviton mass improves the heat engine efficiency significantly. The situation is more complicated for the five-dimensional neutral black holes since the constant which corresponds to the third massive potential also contributes to the efficiency. It is also shown that the existence of graviton mass can improve the heat engine efficiency. Moreover, we probe how the massive gravity influences the behavior of the heat engine efficiency approaching the Carnot efficiency.

  13. Application of sorption heat pumps for increasing of new power sources efficiency

    NASA Astrophysics Data System (ADS)

    Vasiliev, L.; Filatova, O.; Tsitovich, A.

    2010-07-01

    In the 21st century the way to increase the efficiency of new sources of energy is directly related with extended exploration of renewable energy. This modern tendency ensures the fuel economy needs to be realized with nature protection. The increasing of new power sources efficiency (cogeneration, trigeneration systems, fuel cells, photovoltaic systems) can be performed by application of solid sorption heat pumps, regrigerators, heat and cold accumulators, heat transformers, natural gas and hydrogen storage systems and efficient heat exchangers.

  14. 76 FR 26286 - Environmental Impacts Statements; Notice of Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ... the Red Bluff Substation, California Desert Conservation Area (CDCA Plan, Riverside County, CA, Review..., Biodiversity, and Natural Production of Anadromous Salmonids, Kittitas County, WA, Review Period Ends: 05/16...

  15. Relaxation Dynamics in Heme Proteins.

    NASA Astrophysics Data System (ADS)

    Scholl, Reinhard Wilhelm

    A protein molecule possesses many conformational substates that are likely arranged in a hierarchy consisting of a number of tiers. A hierarchical organization of conformational substates is expected to give rise to a multitude of nonequilibrium relaxation phenomena. If the temperature is lowered, transitions between substates of higher tiers are frozen out, and relaxation processes characteristic of lower tiers will dominate the observational time scale. This thesis addresses the following questions: (i) What is the energy landscape of a protein? How does the landscape depend on the environment such as pH and viscosity, and how can it be connected to specific structural parts? (ii) What relaxation phenomena can be observed in a protein? Which are protein specific, and which occur in other proteins? How does the environment influence relaxations? (iii) What functional form best describes relaxation functions? (iv) Can we connect the motions to specific structural parts of the protein molecule, and are these motions important for the function of the protein?. To this purpose, relaxation processes after a pressure change are studied in carbonmonoxy (CO) heme proteins (myoglobin-CO, substrate-bound and substrate-free cytochrome P450cam-CO, chloroperoxidase-CO, horseradish peroxidase -CO) between 150 K and 250 K using FTIR spectroscopy to monitor the CO bound to the heme iron. Two types of p -relaxation experiments are performed: p-release (200 to ~eq40 MPa) and p-jump (~eq40 to 200 MPa) experiments. Most of the relaxations fall into one of three groups and are characterized by (i) nonexponential time dependence and non-Arrhenius temperature dependence (FIM1( nu), FIM1(Gamma)); (ii) exponential time dependence and non-Arrhenius temperature dependence (FIM0(A_{i}to A_{j})); exponential time dependence and Arrhenius temperature dependence (FIMX( nu)). The influence of pH is studied in myoglobin-CO and shown to have a strong influence on the substate population of the highest tier, tier 0, but not on the relaxation rates. Two different viscosities in myoglobin-CO are compared. The dependence of relaxations on the thermodynamic history of a sample is shown. For substrate-free P450cam-CO, relaxations after a p-jump are observed far above the glass transition of the protein-solvent system.

  16. Thermal and Denaturation Studies of the Time-Resolved Fluorescence Decay of Human Superoxide Dismutase

    NASA Astrophysics Data System (ADS)

    Silva, Norberto De Jesus

    Previous studies have shown that time-resolved fluorescence decay of various single tryptophan proteins is best described by a distribution of fluorescence lifetimes rather than one or two lifetimes. The thermal dependence of the lifetime distributions is consistent with the hypothesis that proteins fluctuate between a hierarchy of many conformational substates. With this scenario as a theoretical framework, the correlations between protein dynamic and structure are investigated by studying the time-resolved fluorescence and anisotropy decay of the single tryptophan (Trp) residue of human superoxide dismutase (HSOD) over a wide range of temperatures and at different denaturant concentrations. First, it is demonstrated that the center of the lifetime distribution can characterize the average deactivation environment of the excited Trp-protein system. A qualitative model is introduced to explain the time-resolved fluorescence decay of HSOD in 80% glycerol over a wide range of temperatures. The dynamical model features isoenergetic conformational substates separated by a hierarchy of energy barriers. The HSOD system is also investigated as a function of denaturant concentration in aqueous solution. As a function of guanidine hydrochloride (GdHCl), the width of the fluorescence lifetime distribution of HSOD displays a maximum which is not coincident with the fully denatured form of HSOD at 6.5M GdHCl. Furthermore, the width for the fully denatured form of HSOD is greater than that of the native form. This is consistent with the scenario that more conformational substates are being created upon denaturation of HSOD. HSOD is a dimeric protein and it was observed that the width of the lifetime distribution of HSOD at intermediate GdHCl concentrations increased with decreasing protein concentration. In addition, the secondary structure of HSOD at intermediate GdHCl concentration does not change with protein concentration. These results suggest that HSOD display structural microheterogeneity which is consistent with the hypothesis of conformational substates. Further analysis show that, during denaturation, the monomeric form of HSOD is an intermediate which displays native-like secondary structure and fluctuating tertiary structure; i.e., the monomeric form of HSOD is a molten globule.

  17. Large Efficient Intelligent Heating Relay Station System

    NASA Astrophysics Data System (ADS)

    Wu, C. Z.; Wei, X. G.; Wu, M. Q.

    2017-12-01

    The design of large efficient intelligent heating relay station system aims at the improvement of the existing heating system in our country, such as low heating efficiency, waste of energy and serious pollution, and the control still depends on the artificial problem. In this design, we first improve the existing plate heat exchanger. Secondly, the ATM89C51 is used to control the whole system and realize the intelligent control. The detection part is using the PT100 temperature sensor, pressure sensor, turbine flowmeter, heating temperature, detection of user end liquid flow, hydraulic, and real-time feedback, feedback signal to the microcontroller through the heating for users to adjust, realize the whole system more efficient, intelligent and energy-saving.

  18. Evaluation of Advanced Stirling Convertor Net Heat Input Correlation Methods Using a Thermal Standard

    NASA Technical Reports Server (NTRS)

    Briggs, Maxwell; Schifer, Nicholas

    2011-01-01

    Test hardware used to validate net heat prediction models. Problem: Net Heat Input cannot be measured directly during operation. Net heat input is a key parameter needed in prediction of efficiency for convertor performance. Efficiency = Electrical Power Output (Measured) divided by Net Heat Input (Calculated). Efficiency is used to compare convertor designs and trade technology advantages for mission planning.

  19. 75 FR 80807 - Environmental Impact Statements; Notice of Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-23

    ..., CA, East County Substation/Tule Wind/ Energia Sierra Juarez Gen-Tie Projects, Construction and.... 20100462, Draft EIS, FWS, CA, Santa Clara Valley Habitat Plan, To Protect and Enhance Ecological Diversity...

  20. The study of the mobile compressor unit heat losses recovery system waste heat exchanger thermal insulation types influence on the operational efficiency

    NASA Astrophysics Data System (ADS)

    Yusha, V. L.; Chernov, G. I.; Kalashnikov, A. M.

    2017-08-01

    The paper examines the mobile compressor unit (MCU) heat losses recovery system waste heat exchanger prototype external thermal insulation types influence on the operational efficiency. The study is conducted by means of the numerical method through the modellingof the heat exchange processes carried out in the waste heat exchanger in ANSUS. Thermaflex, mineral wool, penofol, water and air were applied as the heat exchanger external insulation. The study results showed the waste heat exchanger external thermal insulationexistence or absence to have a significant impact on the heat exchanger operational efficiency.

  1. SOUTH FRONT AND EAST SIDE. January, 1998 Edwards Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SOUTH FRONT AND EAST SIDE. January, 1998 - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Electrical Substation, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  2. 75 FR 4338 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... administered by Rural Business Service (RBS) through Rural Development State and sub-State Offices serving each... current economic crisis. The information is used by RBS loan officers and approval officials to determine...

  3. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4130 Surface electric...

  4. A Multi-agent Based Cooperative Voltage and Reactive Power Control

    NASA Astrophysics Data System (ADS)

    Ishida, Masato; Nagata, Takeshi; Saiki, Hiroshi; Shimada, Ikuhiko; Hatano, Ryousuke

    In order to maintain system voltage within the optimal range and prevent voltage instability phenomena before they occur, a variety of phase modifying equipment is installed in optimal locations throughout the power system network and a variety of methods of voltage reactive control are employed. The proposed system divided the traditional method to control voltage and reactive power into two sub problems; “voltage control” to adjust the secondary bus voltage of substations, and “reactive power control” to adjust the primary bus voltage. In this system, two types of agents are installed in substations in order to cooperate “voltage control” and “reactive power control”. In order to verify the performance of the proposed method, it has been applied to the model network system. The results confirm that our proposed method is able to control violent fluctuations in load.

  5. ANCA: Anharmonic Conformational Analysis of Biomolecular Simulations.

    PubMed

    Parvatikar, Akash; Vacaliuc, Gabriel S; Ramanathan, Arvind; Chennubhotla, S Chakra

    2018-05-08

    Anharmonicity in time-dependent conformational fluctuations is noted to be a key feature of functional dynamics of biomolecules. Although anharmonic events are rare, long-timescale (μs-ms and beyond) simulations facilitate probing of such events. We have previously developed quasi-anharmonic analysis to resolve higher-order spatial correlations and characterize anharmonicity in biomolecular simulations. In this article, we have extended this toolbox to resolve higher-order temporal correlations and built a scalable Python package called anharmonic conformational analysis (ANCA). ANCA has modules to: 1) measure anharmonicity in the form of higher-order statistics and its variation as a function of time, 2) output a storyboard representation of the simulations to identify key anharmonic conformational events, and 3) identify putative anharmonic conformational substates and visualization of transitions between these substates. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  6. Digital interface of electronic transformers based on embedded system

    NASA Astrophysics Data System (ADS)

    Shang, Qiufeng; Qi, Yincheng

    2008-10-01

    Benefited from digital interface of electronic transformers, information sharing and system integration in substation can be realized. An embedded system-based digital output scheme of electronic transformers is proposed. The digital interface is designed with S3C44B0X 32bit RISC microprocessor as the hardware platform. The μCLinux operation system (OS) is transplanted on ARM7 (S3C44B0X). Applying Ethernet technology as the communication mode in the substation automation system is a new trend. The network interface chip RTL8019AS is adopted. Data transmission is realized through the in-line TCP/IP protocol of uClinux embedded OS. The application result and character analysis show that the design can meet the real-time and reliability requirements of IEC60044-7/8 electronic voltage/current instrument transformer standards.

  7. Research on the Wire Network Signal Prediction Based on the Improved NNARX Model

    NASA Astrophysics Data System (ADS)

    Zhang, Zipeng; Fan, Tao; Wang, Shuqing

    It is difficult to obtain accurately the wire net signal of power system's high voltage power transmission lines in the process of monitoring and repairing. In order to solve this problem, the signal measured in remote substation or laboratory is employed to make multipoint prediction to gain the needed data. But, the obtained power grid frequency signal is delay. In order to solve the problem, an improved NNARX network which can predict frequency signal based on multi-point data collected by remote substation PMU is describes in this paper. As the error curved surface of the NNARX network is more complicated, this paper uses L-M algorithm to train the network. The result of the simulation shows that the NNARX network has preferable predication performance which provides accurate real time data for field testing and maintenance.

  8. Dynamic Simulation on the Installation Process of HGIS in Transformer Substation

    NASA Astrophysics Data System (ADS)

    Lin, Tao; Li, Shaohua; Wang, Hu; Che, Deyong; Qi, Guangcai; Yao, Jianfeng; Zhang, Qingzhe

    The technological requirements of Hypid Gas Insulated Switchgear (HGIS) installation in transformer substation is high and the control points of quality is excessive. Most of the engineers and technicians in the construction enterprises are not familiar with equipments of HGIS. In order to solve these problem, equipments of HGIS is modeled on the computer by SolidWorks software. Installation process of civil foundation and closed-type equipments is optimized dynamically with virtual assemble technology. Announcements and application work are composited into animation file. Skills of modeling and simulation is tidied classify as well. The result of the visual dynamic simulation can instruct the actual construction process of HGIS to a certain degree and can promote reasonable construction planning and management. It can also improve the method and quality of staff training for electric power construction enterprises.

  9. Frustration-guided motion planning reveals conformational transitions in proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Budday, Dominik; Fonseca, Rasmus; Leyendecker, Sigrid

    Proteins exist as conformational ensembles, exchanging between substates to perform their function. Advances in experimental techniques yield unprecedented access to structural snapshots of their conformational landscape. However, computationally modeling how proteins use collective motions to transition between substates is challenging owing to a rugged landscape and large energy barriers. Here in this paper, we present a new, robotics-inspired motion planning procedure called dCCRRT that navigates the rugged landscape between substates by introducing dynamic, interatomic constraints to modulate frustration. The constraints balance non-native contacts and flexibility, and instantaneously redirect the motion towards sterically favorable conformations. On a test set of eightmore » proteins determined in two conformations separated by, on average, 7.5Å root mean square deviation (RMSD), our pathways reduced the Cα atom RMSD to the goal conformation by 78%, outperforming peer methods. Additionally, we then applied dCC-RRT to examine how collective, small-scale motions of four side-chains in the active site of cyclophilin A propagate through the protein. dCC-RRT uncovered a spatially contiguous network of residues linked by steric interactions and collective motion connecting the active site to a recently proposed, non-canonical capsid binding site 25Å away, rationalizing NMR and multi-temperature crystallography experiments. In all, dCC-RRT can reveal detailed, all-atom molecular mechanisms for small and large amplitude motions.Source code and binaries are freely available at https://github.com/ExcitedStates/KGS/.« less

  10. Frustration-guided motion planning reveals conformational transitions in proteins.

    PubMed

    Budday, Dominik; Fonseca, Rasmus; Leyendecker, Sigrid; van den Bedem, Henry

    2017-10-01

    Proteins exist as conformational ensembles, exchanging between substates to perform their function. Advances in experimental techniques yield unprecedented access to structural snapshots of their conformational landscape. However, computationally modeling how proteins use collective motions to transition between substates is challenging owing to a rugged landscape and large energy barriers. Here, we present a new, robotics-inspired motion planning procedure called dCC-RRT that navigates the rugged landscape between substates by introducing dynamic, interatomic constraints to modulate frustration. The constraints balance non-native contacts and flexibility, and instantaneously redirect the motion towards sterically favorable conformations. On a test set of eight proteins determined in two conformations separated by, on average, 7.5 Å root mean square deviation (RMSD), our pathways reduced the Cα atom RMSD to the goal conformation by 78%, outperforming peer methods. We then applied dCC-RRT to examine how collective, small-scale motions of four side-chains in the active site of cyclophilin A propagate through the protein. dCC-RRT uncovered a spatially contiguous network of residues linked by steric interactions and collective motion connecting the active site to a recently proposed, non-canonical capsid binding site 25 Å away, rationalizing NMR and multi-temperature crystallography experiments. In all, dCC-RRT can reveal detailed, all-atom molecular mechanisms for small and large amplitude motions. Source code and binaries are freely available at https://github.com/ExcitedStates/KGS/. © 2017 Wiley Periodicals, Inc.

  11. Frustration-guided motion planning reveals conformational transitions in proteins

    DOE PAGES

    Budday, Dominik; Fonseca, Rasmus; Leyendecker, Sigrid; ...

    2017-07-12

    Proteins exist as conformational ensembles, exchanging between substates to perform their function. Advances in experimental techniques yield unprecedented access to structural snapshots of their conformational landscape. However, computationally modeling how proteins use collective motions to transition between substates is challenging owing to a rugged landscape and large energy barriers. Here in this paper, we present a new, robotics-inspired motion planning procedure called dCCRRT that navigates the rugged landscape between substates by introducing dynamic, interatomic constraints to modulate frustration. The constraints balance non-native contacts and flexibility, and instantaneously redirect the motion towards sterically favorable conformations. On a test set of eightmore » proteins determined in two conformations separated by, on average, 7.5Å root mean square deviation (RMSD), our pathways reduced the Cα atom RMSD to the goal conformation by 78%, outperforming peer methods. Additionally, we then applied dCC-RRT to examine how collective, small-scale motions of four side-chains in the active site of cyclophilin A propagate through the protein. dCC-RRT uncovered a spatially contiguous network of residues linked by steric interactions and collective motion connecting the active site to a recently proposed, non-canonical capsid binding site 25Å away, rationalizing NMR and multi-temperature crystallography experiments. In all, dCC-RRT can reveal detailed, all-atom molecular mechanisms for small and large amplitude motions.Source code and binaries are freely available at https://github.com/ExcitedStates/KGS/.« less

  12. Finite-size effect on optimal efficiency of heat engines.

    PubMed

    Tajima, Hiroyasu; Hayashi, Masahito

    2017-07-01

    The optimal efficiency of quantum (or classical) heat engines whose heat baths are n-particle systems is given by the strong large deviation. We give the optimal work extraction process as a concrete energy-preserving unitary time evolution among the heat baths and the work storage. We show that our optimal work extraction turns the disordered energy of the heat baths to the ordered energy of the work storage, by evaluating the ratio of the entropy difference to the energy difference in the heat baths and the work storage, respectively. By comparing the statistical mechanical optimal efficiency with the macroscopic thermodynamic bound, we evaluate the accuracy of the macroscopic thermodynamics with finite-size heat baths from the statistical mechanical viewpoint. We also evaluate the quantum coherence effect on the optimal efficiency of the cycle processes without restricting their cycle time by comparing the classical and quantum optimal efficiencies.

  13. Relations between the efficiency, power and dissipation for linear irreversible heat engine at maximum trade-off figure of merit

    NASA Astrophysics Data System (ADS)

    Iyyappan, I.; Ponmurugan, M.

    2018-03-01

    A trade of figure of merit (\\dotΩ ) criterion accounts the best compromise between the useful input energy and the lost input energy of the heat devices. When the heat engine is working at maximum \\dotΩ criterion its efficiency increases significantly from the efficiency at maximum power. We derive the general relations between the power, efficiency at maximum \\dotΩ criterion and minimum dissipation for the linear irreversible heat engine. The efficiency at maximum \\dotΩ criterion has the lower bound \

  14. Characterizing RNA ensembles from NMR data with kinematic models

    PubMed Central

    Fonseca, Rasmus; Pachov, Dimitar V.; Bernauer, Julie; van den Bedem, Henry

    2014-01-01

    Functional mechanisms of biomolecules often manifest themselves precisely in transient conformational substates. Researchers have long sought to structurally characterize dynamic processes in non-coding RNA, combining experimental data with computer algorithms. However, adequate exploration of conformational space for these highly dynamic molecules, starting from static crystal structures, remains challenging. Here, we report a new conformational sampling procedure, KGSrna, which can efficiently probe the native ensemble of RNA molecules in solution. We found that KGSrna ensembles accurately represent the conformational landscapes of 3D RNA encoded by NMR proton chemical shifts. KGSrna resolves motionally averaged NMR data into structural contributions; when coupled with residual dipolar coupling data, a KGSrna ensemble revealed a previously uncharacterized transient excited state of the HIV-1 trans-activation response element stem–loop. Ensemble-based interpretations of averaged data can aid in formulating and testing dynamic, motion-based hypotheses of functional mechanisms in RNAs with broad implications for RNA engineering and therapeutic intervention. PMID:25114056

  15. Magnetic Heat Pump Containing Flow Diverters

    NASA Technical Reports Server (NTRS)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  16. Beale Air Force Base, Perimeter Acquisition Vehicle Entry PhasedArray Warning ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Electric Substation, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  17. Looking north Beale Air Force Base, Perimeter Acquisition Vehicle ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking north - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Electric Substation, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  18. CNPQ/INPE LANDSAT system

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Barbosa, M. N.; Escada, J. B., Jr.

    1983-01-01

    The current status of the Brazilian LANDSAT facilities is described and main accomplishments are outlined. Receiving, recording, and processing substations and data distribution centers are discussed. Examples of the preliminary TM product produced by the Brazilian station are given.

  19. Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Jacobson, David

    The high-efficiency boiler and furnace measure produces gas heating savings resulting from installation of more energy-efficient heating equipment in a residence. Such equipment, which ranges in size from 60 kBtu/hr to 300 kBtu/hr, is installed primarily in single-family homes and multifamily buildings with individual heating systems for each dwelling unit. This protocol does not cover integrated heating and water heating units which can be used in lieu of space heating only equipment.

  20. Efficiency optimization of a closed indirectly fired gas turbine cycle working under two variable-temperature heat reservoirs

    NASA Astrophysics Data System (ADS)

    Ma, Zheshu; Wu, Jieer

    2011-08-01

    Indirectly or externally fired gas turbines (IFGT or EFGT) are interesting technologies under development for small and medium scale combined heat and power (CHP) supplies in combination with micro gas turbine technologies. The emphasis is primarily on the utilization of the waste heat from the turbine in a recuperative process and the possibility of burning biomass even "dirty" fuel by employing a high temperature heat exchanger (HTHE) to avoid the combustion gases passing through the turbine. In this paper, finite time thermodynamics is employed in the performance analysis of a class of irreversible closed IFGT cycles coupled to variable temperature heat reservoirs. Based on the derived analytical formulae for the dimensionless power output and efficiency, the efficiency optimization is performed in two aspects. The first is to search the optimum heat conductance distribution corresponding to the efficiency optimization among the hot- and cold-side of the heat reservoirs and the high temperature heat exchangers for a fixed total heat exchanger inventory. The second is to search the optimum thermal capacitance rate matching corresponding to the maximum efficiency between the working fluid and the high-temperature heat reservoir for a fixed ratio of the thermal capacitance rates of the two heat reservoirs. The influences of some design parameters on the optimum heat conductance distribution, the optimum thermal capacitance rate matching and the maximum power output, which include the inlet temperature ratio of the two heat reservoirs, the efficiencies of the compressor and the gas turbine, and the total pressure recovery coefficient, are provided by numerical examples. The power plant configuration under optimized operation condition leads to a smaller size, including the compressor, turbine, two heat reservoirs and the HTHE.

  1. Experimental evaluation of heat transfer efficiency of nanofluid in a double pipe heat exchanger and prediction of experimental results using artificial neural networks

    NASA Astrophysics Data System (ADS)

    Maddah, Heydar; Ghasemi, Nahid

    2017-12-01

    In this study, heat transfer efficiency of water and iron oxide nanofluid in a double pipe heat exchanger equipped with a typical twisted tape is experimentally investigated and impacts of the concentration of nanofluid and twisted tape on the heat transfer efficiency are also studied. Experiments were conducted under the laminar and turbulent flow for Reynolds numbers in the range of 1000 to 6000 and the concentration of nanofluid was 0.01, 0.02 and 0.03 wt%. In order to model and predict the heat transfer efficiency, an artificial neural network was used. The temperature of the hot fluid (nanofluid), the temperature of the cold fluid (water), mass flow rate of hot fluid (nanofluid), mass flow rate of cold fluid (water), the concentration of nanofluid and twist ratio are input data in artificial neural network and heat transfer is output or target. Heat transfer efficiency in the presence of 0.03 wt% nanofluid increases by 30% while using both the 0.03 wt% nanofluid and twisted tape with twist ratio 2 increases the heat transfer efficiency by 60%. Implementation of various structures of neural network with different number of neurons in the middle layer showed that 1-10-6 arrangement with the correlation coefficient 0.99181 and normal root mean square error 0.001621 is suggested as a desirable arrangement. The above structure has been successful in predicting 72% to 97%of variation in heat transfer efficiency characteristics based on the independent variables changes. In total, comparing the predicted results in this study with other studies and also the statistical measures shows the efficiency of artificial neural network.

  2. Maximum efficiency of ideal heat engines based on a small system: correction to the Carnot efficiency at the nanoscale.

    PubMed

    Quan, H T

    2014-06-01

    We study the maximum efficiency of a heat engine based on a small system. It is revealed that due to the finiteness of the system, irreversibility may arise when the working substance contacts with a heat reservoir. As a result, there is a working-substance-dependent correction to the Carnot efficiency. We derive a general and simple expression for the maximum efficiency of a Carnot cycle heat engine in terms of the relative entropy. This maximum efficiency approaches the Carnot efficiency asymptotically when the size of the working substance increases to the thermodynamic limit. Our study extends Carnot's result of the maximum efficiency to an arbitrary working substance and elucidates the subtlety of thermodynamic laws in small systems.

  3. Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler

    NASA Astrophysics Data System (ADS)

    Cao, Weixue; Liu, Fengguo; You, Xue-yi

    2018-07-01

    Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.

  4. Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler

    NASA Astrophysics Data System (ADS)

    Cao, Weixue; Liu, Fengguo; You, Xue-yi

    2018-01-01

    Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.

  5. Integration of Decentralized Thermal Storages Within District Heating (DH) Networks

    NASA Astrophysics Data System (ADS)

    Schuchardt, Georg K.

    2016-12-01

    Thermal Storages and Thermal Accumulators are an important component within District Heating (DH) systems, adding flexibility and offering additional business opportunities for these systems. Furthermore, these components have a major impact on the energy and exergy efficiency as well as the heat losses of the heat distribution system. Especially the integration of Thermal Storages within ill-conditioned parts of the overall DH system enhances the efficiency of the heat distribution. Regarding an illustrative and simplified example for a DH system, the interactions of different heat storage concepts (centralized and decentralized) and the heat losses, energy and exergy efficiencies will be examined by considering the thermal state of the heat distribution network.

  6. Thermodynamic analysis of alternate energy carriers, hydrogen and chemical heat pipes

    NASA Technical Reports Server (NTRS)

    Cox, K. E.; Carty, R. H.; Conger, W. L.; Soliman, M. A.; Funk, J. E.

    1976-01-01

    The paper discusses the production concept and efficiency of two new energy transmission and storage media intended to overcome the disadvantages of electricity as an overall energy carrier. These media are hydrogen produced by water-splitting and the chemical heat pipe. Hydrogen can be transported or stored, and burned as energy is needed, forming only water and thus obviating pollution problems. The chemical heat pipe envisions a system in which heat is stored as the heat of reaction in chemical species. The thermodynamic analysis of these two methods is discussed in terms of first-law and second-law efficiency. It is concluded that chemical heat pipes offer large advantages over thermochemical hydrogen generation schemes on a first-law efficiency basis except for the degradation of thermal energy in temperature thus providing a source of low-temperature (800 K) heat for process heat applications. On a second-law efficiency basis, hydrogen schemes are superior in that the amount of available work is greater as compared to chemical heat pipes.

  7. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  8. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  9. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  10. Electricity Delivery and its Environmental Impacts

    EPA Pesticide Factsheets

    Explains electricity delivery in the U.S. and its impacts on the environment. After a centralized power plant generates electricity, the electricity must be delivered to the end-user. Follow the path of electricity through transmission, substation, and dis

  11. 6. SECOND FLOOR, LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. SECOND FLOOR, LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR

  12. 5. WEST MEZZANINE, LOOKING NORTH, AREA PREVIOUSLY CONTAINED HIGH TENSION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. WEST MEZZANINE, LOOKING NORTH, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR

  13. 7 CFR 1728.98 - Electric standards and specifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... for Pad-Mounted Transformers (Single and Three-Phase) (1-77). (19) Bulletin 50-74 (U-6), RUS... Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78). (21) Bulletin 1728F-700...

  14. 7 CFR 1728.98 - Electric standards and specifications.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... for Pad-Mounted Transformers (Single and Three-Phase) (1-77). (19) Bulletin 50-74 (U-6), RUS... Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78). (21) Bulletin 1728F-700...

  15. 7 CFR 1728.98 - Electric standards and specifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... for Pad-Mounted Transformers (Single and Three-Phase) (1-77). (19) Bulletin 50-74 (U-6), RUS... Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78). (21) Bulletin 1728F-700...

  16. 7 CFR 1728.97 - Incorporation by reference of electric standards and specifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...-73 (U-5), RUS Specifications for Pad-Mounted Transformers (Single and Three-Phase) (1-77) Bulletin 50...), RUS Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78) Bulletin...

  17. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  18. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  19. Effects of aging on the structural, mechanical, and thermal properties of the silicone rubber current transformer insulation bushing for a 500 kV substation.

    PubMed

    Wang, Zhigao; Zhang, Xinghai; Wang, Fangqiang; Lan, Xinsheng; Zhou, Yiqian

    2016-01-01

    In order to analyze the cracking and aging reason of the silicone rubber current transformer (CT) insulation bushing used for 8 years from a 500 kV alternating current substation, characteristics including Fourier transform infrared (FTIR) spectroscopy, mechanical properties analysis, hardness, and thermo gravimetric analysis have been carried out. The FTIR results indicated that the external surface of the silicone rubber CT insulation bushing suffered from more serious aging than the internal part, fracture of side chain Si-C bond was much more than the backbone. Mechanical properties and thermal stability results illustrated that the main aging reasons were the breakage of side chain Si-C bond and the excessive cross-linking reaction of the backbone. This study can provide valuable basis for evaluating degradation mechanism and aging state of the silicone rubber insulation bushing in electric power field.

  20. Extremum Seeking Control of Smart Inverters for VAR Compensation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, Daniel; Negrete-Pincetic, Matias; Stewart, Emma

    2015-09-04

    Reactive power compensation is used by utilities to ensure customer voltages are within pre-defined tolerances and reduce system resistive losses. While much attention has been paid to model-based control algorithms for reactive power support and Volt Var Optimization (VVO), these strategies typically require relatively large communications capabilities and accurate models. In this work, a non-model-based control strategy for smart inverters is considered for VAR compensation. An Extremum Seeking control algorithm is applied to modulate the reactive power output of inverters based on real power information from the feeder substation, without an explicit feeder model. Simulation results using utility demand informationmore » confirm the ability of the control algorithm to inject VARs to minimize feeder head real power consumption. In addition, we show that the algorithm is capable of improving feeder voltage profiles and reducing reactive power supplied by the distribution substation.« less

  1. The laboratory millimeter-wave spectrum of methyl formate in its ground torsional E state

    NASA Technical Reports Server (NTRS)

    Plummer, G. M.; Herbst, E.; De Lucia, F. C.; Blake, G. A.

    1986-01-01

    Over 250 rotational transitions of the internal rotor methyl formate (HCOOCH3) in its ground v(t) = 0 degenerate (E) torsional substate have been measured in the millimeter-wave spectral region. These data and a number of E-state lines identified by several other workers have been analyzed using an extension of the classical principal-axis method in the high barrier limit. The resulting rotational constants allow accurate prediction of the v(t) = 0 E substate methyl formate spectrum below 300 GHz between states with angular momentum J not greater than 30 and rotational energy of not more than 350/cm. The calculated transition frequencies for the E state, when combined with the results of the previous analysis of the ground-symmetric, nondegenerate state, account for over 200 of the emission lines observed toward Orion in a recent survey of the 215-265 GHz band.

  2. Preventive overhaul time for power transformers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarmadi, M.; Rouhi, J.; Fayyaz, A.

    Power transformers are the major piece of equipment in high-voltage substations. A considerable number of these transformers exist in Iran`s integrated network. Due to the climate diversity and improper usage, many of these transformers age rapidly, suffer failure and are taken out of service before half their useful life. At the present time the utility companies have no specific time-frame and plan for preventive overhaul. Detection of preventive overhaul time will increase the remaining life of transformers and improve the reliability of substations. An exact check of the remaining lifetime of transformers is not yet possible by available diagnostic techniques.more » In this paper, the authors present a method of identifying the right time for preventive overhaul in 63 kV power transformers. This method is developed based on 25 year transformer performance records in Northern Iran (subtropical climate) and with the utilization of studies done by electrical engineering communities world-wide.« less

  3. Study of seismic response and vibration control of High voltage electrical equipment damper based on TMD

    NASA Astrophysics Data System (ADS)

    Liu, Chuncheng; Wang, Chongyang; Mao, Long; Zha, Chuanming

    2016-11-01

    Substation high voltage electrical equipment such as mutual inductor, circuit interrupter, disconnecting switch, etc., has played a key role in maintaining the normal operation of the power system. When the earthquake disaster, the electrical equipment of the porcelain in the transformer substation is the most easily to damage, causing great economic losses. In this paper, using the method of numerical analysis, the establishment of a typical high voltage electrical equipment of three dimensional finite element model, to study the seismic response of a typical SF6 circuit breaker, at the same time, analysis and contrast the installation ring tuned mass damper (TMD damper for short), by changing the damper damping coefficient and the mass block, install annular TMD vibration control effect is studied. The results of the study for guiding the seismic design of high voltage electrical equipment to provide valuable reference.

  4. A dynamic mechanism for allosteric activation of Aurora kinase A by activation loop phosphorylation.

    PubMed

    Ruff, Emily F; Muretta, Joseph M; Thompson, Andrew R; Lake, Eric W; Cyphers, Soreen; Albanese, Steven K; Hanson, Sonya M; Behr, Julie M; Thomas, David D; Chodera, John D; Levinson, Nicholas M

    2018-02-21

    Many eukaryotic protein kinases are activated by phosphorylation on a specific conserved residue in the regulatory activation loop, a post-translational modification thought to stabilize the active DFG-In state of the catalytic domain. Here we use a battery of spectroscopic methods that track different catalytic elements of the kinase domain to show that the ~100 fold activation of the mitotic kinase Aurora A (AurA) by phosphorylation occurs without a population shift from the DFG-Out to the DFG-In state, and that the activation loop of the activated kinase remains highly dynamic. Instead, molecular dynamics simulations and electron paramagnetic resonance experiments show that phosphorylation triggers a switch within the DFG-In subpopulation from an autoinhibited DFG-In substate to an active DFG-In substate, leading to catalytic activation. This mechanism raises new questions about the functional role of the DFG-Out state in protein kinases. © 2018, Ruff et al.

  5. Photovoltaic central station step and touch potential considerations in grounding system design

    NASA Technical Reports Server (NTRS)

    Engmann, G.

    1983-01-01

    The probability of hazardous step and touch potentials is an important consideration in central station grounding system design. Steam turbine generating station grounding system design is based on accepted industry practices and there is extensive in-service experience with these grounding systems. A photovoltaic (PV) central station is a relatively new concept and there is limited experience with PV station grounding systems. The operation and physical configuration of a PV central station is very different from a steam electric station. A PV station bears some similarity to a substation and the PV station step and touch potentials might be addressed as they are in substation design. However, the PV central station is a generating station and it is appropriate to examine the effect that the differences and similarities of the two types of generating stations have on step and touch potential considerations.

  6. Two-dimensional vibrational spectroscopy of the amide I band of crystalline acetanilide: Fermi resonance, conformational substates, or vibrational self-trapping?

    NASA Astrophysics Data System (ADS)

    Edler, J.; Hamm, P.

    2003-08-01

    Two-dimensional infrared (2D-IR) spectroscopy is applied to investigate acetanilide, a molecular crystal consisting of quasi-one-dimensional hydrogen bonded peptide units. The amide-I band exhibits a double peak structure, which has been attributed to different mechanisms including vibrational self-trapping, a Fermi resonance, or the existence of two conformational substates. The 2D-IR spectrum of crystalline acetanilide is compared with that of two different molecular systems: (i) benzoylchloride, which exhibits a strong symmetric Fermi resonance and (ii) N-methylacetamide dissolved in methanol which occurs in two spectroscopically distinguishable conformations. Both 2D-IR spectra differ significantly from that of crystalline acetanilide, proving that these two alternative mechanisms cannot account for the anomalous spectroscopy of crystalline acetanilide. On the other hand, vibrational self-trapping of the amide-I band can naturally explain the 2D-IR response.

  7. How main-chains of proteins explore the free-energy landscape in native states.

    PubMed

    Senet, Patrick; Maisuradze, Gia G; Foulie, Colette; Delarue, Patrice; Scheraga, Harold A

    2008-12-16

    Understanding how a single native protein diffuses on its free-energy landscape is essential to understand protein kinetics and function. The dynamics of a protein is complex, with multiple relaxation times reflecting a hierarchical free-energy landscape. Using all-atom molecular dynamics simulations of an alpha/beta protein (crambin) and a beta-sheet polypeptide (BS2) in their "native" states, we demonstrate that the mean-square displacement of dihedral angles, defined by 4 successive C(alpha) atoms, increases as a power law of time, t(alpha), with an exponent alpha between 0.08 and 0.39 (alpha = 1 corresponds to Brownian diffusion), at 300 K. Residues with low exponents are located mainly in well-defined secondary elements and adopt 1 conformational substate. Residues with high exponents are found in loops/turns and chain ends and exist in multiple conformational substates, i.e., they move on multiple-minima free-energy profiles.

  8. How main-chains of proteins explore the free-energy landscape in native states

    PubMed Central

    Senet, Patrick; Maisuradze, Gia G.; Foulie, Colette; Delarue, Patrice; Scheraga, Harold A.

    2008-01-01

    Understanding how a single native protein diffuses on its free-energy landscape is essential to understand protein kinetics and function. The dynamics of a protein is complex, with multiple relaxation times reflecting a hierarchical free-energy landscape. Using all-atom molecular dynamics simulations of an α/β protein (crambin) and a β-sheet polypeptide (BS2) in their “native” states, we demonstrate that the mean-square displacement of dihedral angles, defined by 4 successive Cα atoms, increases as a power law of time, tα, with an exponent α between 0.08 and 0.39 (α = 1 corresponds to Brownian diffusion), at 300 K. Residues with low exponents are located mainly in well-defined secondary elements and adopt 1 conformational substate. Residues with high exponents are found in loops/turns and chain ends and exist in multiple conformational substates, i.e., they move on multiple-minima free-energy profiles. PMID:19073932

  9. Economic evaluation of distribution system smart grid investments

    DOE PAGES

    Onen, Ahmet; Cheng, Danling; Broadwater, Robert P.; ...

    2014-12-31

    This paper investigates economic benefits of smart grid automation investments. A system consisting of 7 substations and 14 feeders is used in the evaluation. Here benefits that can be quantified in terms of dollar savings are considered, termed “hard dollar” benefits. Smart Grid investment evaluations to be considered include investments in improved efficiency, more cost effective use of existing system capacity with automated switches, and coordinated control of capacitor banks and voltage regulators. These Smart Grid evaluations are sequentially ordered, resulting in a series of incremental hard dollar benefits. Hard dollar benefits come from improved efficiency, delaying large capital equipmentmore » investments, shortened storm restoration times, and reduced customer energy use. Analyses used in the evaluation involve hourly power flow analysis over multiple years and Monte Carlo simulations of switching operations during storms using a reconfiguration for restoration algorithm. The economic analysis uses the time varying value of the Locational Marginal Price. Algorithms used include reconfiguration for restoration involving either manual or automated switches and coordinated control involving two modes of control. Field validations of phase balancing and capacitor design results are presented. The evaluation shows that investments in automation can improve performance while at the same time lowering costs.« less

  10. Assessment of thermal efficiency of heat recovery coke making

    NASA Astrophysics Data System (ADS)

    Tiwari, H. P.; Saxena, V. K.; Haldar, S. K.; Sriramoju, S. K.

    2017-08-01

    The heat recovery stamp charge coke making process is quite complicated due to the evolved volatile matter during coking, is partially combusted in oven crown and sole flue in a controlled manner to provide heat for producing metallurgical coke. Therefore, the control and efficient utilization of heat in the oven crown, and sole flue is difficult, which directly affects the operational efficiency. Considering the complexity and importance of thermal efficiency, evolution of different gases, combustion of gasses in oven crown and sole flue, and heating process of coke oven has been studied. A nonlinear regression methodology was used to predict temperature profile of different depth of coal cake during the coking. It was observed that the predicted temperature profile is in good agreement with the actual temperature profile (R2 = 0.98) and is validated with the actual temperature profile of other ovens. A complete study is being done to calculate the material balance, heat balance, and heat losses. This gives an overall understanding of heat flow which affects the heat penetration into the coal cake. The study confirms that 60% heat was utilized during coking.

  11. Long-duration heat load measurement approach by novel apparatus design and highly efficient algorithm

    NASA Astrophysics Data System (ADS)

    Zhu, Yanwei; Yi, Fajun; Meng, Songhe; Zhuo, Lijun; Pan, Weizhen

    2017-11-01

    Improving the surface heat load measurement technique for vehicles in aerodynamic heating environments is imperative, regarding aspects of both the apparatus design and identification efficiency. A simple novel apparatus is designed for heat load identification, taking into account the lessons learned from several aerodynamic heating measurement devices. An inverse finite difference scheme (invFDM) for the apparatus is studied to identify its surface heat flux from the interior temperature measurements with high efficiency. A weighted piecewise regression filter is also proposed for temperature measurement prefiltering. Preliminary verification of the invFDM scheme and the filter is accomplished via numerical simulation experiments. Three specific pieces of apparatus have been concretely designed and fabricated using different sensing materials. The aerodynamic heating process is simulated by an inductively coupled plasma wind tunnel facility. The identification of surface temperature and heat flux from the temperature measurements is performed by invFDM. The results validate the high efficiency, reliability and feasibility of heat load measurements with different heat flux levels utilizing the designed apparatus and proposed method.

  12. Determining insulation condition of 110kV instrument transformers. Linking PD measurement results from both gas chromatography and electrical method

    NASA Astrophysics Data System (ADS)

    Dan, C.; Morar, R.

    2017-05-01

    Working methods for on site testing of insulations: Gas chromatography (using the TFGA-P200 chromatographer); Electrical measurements of partial discharge levels using the digital detection, recording, analysis and partial discharge acquisition system, MPD600. First performed, between 2000-2015, were the chromatographic analyses concerning electrical insulating environments of: 102 current transformers, 110kV. Items in operation, functioning in 110/20kV substations. 38 voltage transformers, 110kV also in operation, functioning in 110/20kV substations. Then, electrical measurements of partial discharge inside instrument transformers, on site (power substations) were made (starting in the year 2009, over a 7-year period, collecting data until the year 2015) according to the provisions of standard EN 61869-1:2007 „Instrument transformers. General requirements”, applying, assimilated to it, type A partial discharge test procedure, using as test voltage the very rated 110kV distribution grid voltage. Given the results of two parallel measurements, containing: to this type of failure specific gas amount (H 2) and the quantitative partial discharge’ level, establishing a clear dependence between the quantity of partial discharges and the type and amount of in oil dissolved gases inside equipments affected by this type of defect: partial discharges, was expected. Of the „population” of instrument transformers subject of the two parallel measurements, the dependency between Q IEC (apparent charge) and (H 2) (hydrogen, gas amount dissolved within their insulating environment) represents a finite assemblage situated between the two limits developed on an empirical basis.

  13. 8. Photocopy of Station Grounding drawing showing floor plans (from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Photocopy of Station Grounding drawing showing floor plans (from the BPA Engineering Vault, Drawing 005319, 3 May 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  14. NORTH REAR AND WEST SIDE, Looking southeast down Saturn Boulevard. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTH REAR AND WEST SIDE, Looking southeast down Saturn Boulevard. February, 1998 - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Electrical Substation, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  15. 30 CFR 57.4160 - Underground electric substations and liquid storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4160... noncombustible materials with equivalent fire protection characteristics. ...

  16. 76 FR 63920 - Eldorado Pumped Storage, LLC.; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-14

    ... Marketplace, McCullough, or Eldorado substations. The tentative source for initial fill of water and evaporation compensation would be the Southern Nevada Water Authority. The specific routing for that water...

  17. 15 CFR 90.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... non-functioning county or statistical equivalent means a sub-state entity that does not function as an... program, an eligible governmental unit also includes the District of Columbia and non-functioning counties or statistical equivalents represented by a FSCPE member agency. ...

  18. 76 FR 16766 - ECOsponsible, Inc.; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... feasibility of the Niagara River Community Hydro Project (Niagara Project or project) to be located on the... electricity to an onshore collection substation and point of interconnection switchyard; (3) an operations and...

  19. River Gardens Intermediate-Care Facility water-to-air heating and air-conditioning demonstration project. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, R.C.

    An integrated system of heat pumps is used to reject heat into or extract heat from circulating water from a shallow well adjacent to the river to demonstrate the efficiency and fuel cost savings of water-to-air heat pumps, without the expense of drilling a deep well. Water is returned unpolluted to the Guadalupe River and is circulated through a five-building complex at River Gardens Intermediate Care Facility for the Mentally Retarded in New Braunfels, Texas. The water is used as a heat source or sink for 122 heat pumps providing space heating and cooling, and for refrigeration and freezer units.more » The system was not installed as designed, which resulted in water pumping loads being higher than the original design. Electrical consumption for pumping water represented 36 to 37% of system electrical consumption. Without the water pumping load, the water-to-air system was an average of 25% more efficient in heating than a comparable air-to-air unit with resistance heating. With water pumping load included, the installed system averaged 17% less efficient in cooling and 19% more efficient in heating than the comparable unit.« less

  20. Unified trade-off optimization for general heat devices with nonisothermal processes.

    PubMed

    Long, Rui; Liu, Wei

    2015-04-01

    An analysis of the efficiency and coefficient of performance (COP) for general heat engines and refrigerators with nonisothermal processes is conducted under the trade-off criterion. The specific heat of the working medium has significant impacts on the optimal configurations of heat devices. For cycles with constant specific heat, the bounds of the efficiency and COP are found to be the same as those obtained through the endoreversible Carnot ones. However, they are independent of the cycle time durations. For cycles with nonconstant specific heat, whose dimensionless contact time approaches infinity, the general alternative upper and lower bounds of the efficiency and COP under the trade-off criteria have been proposed under the asymmetric limits. Furthermore, when the dimensionless contact time approaches zero, the endoreversible Carnot model is recovered. In addition, the efficiency and COP bounds of different kinds of actual heat engines and refrigerators have also been analyzed. This paper may provide practical insight for designing and operating actual heat engines and refrigerators.

  1. Energy saving analysis on mine-water source heat pump in a residential district of Henan province, central China

    NASA Astrophysics Data System (ADS)

    Wang, Hong; Duan, Huanlin; Chen, Aidong

    2018-02-01

    In this paper, the mine-water source heat pump system is proposed in residential buildings of a mining community. The coefficient of performance (COP) and the efficiency of exergy are analyzed. The results show that the COP and exergy efficiency of the mine-water source heat pump are improved, the exergy efficiency of mine-water source heat pump is more than 10% higher than that of the air source heat pump.The electric power conservation measure of “peak load shifting” is also emphasized in this article. It shows that itis a very considerable cost in the electric saving by adopting the trough period electricity to produce hot water. Due to the proper temperature of mine water, the mine-watersource heat pump unit is more efficient and stable in performance, which further shows the advantage of mine-water source heat pump in energy saving and environmental protection. It provides reference to the design of similar heat pump system as well.

  2. Increasing the Efficiency of Maple Sap Evaporators with Heat Exchangers

    Treesearch

    Lawrence D. Garrett; Howard Duchacek; Mariafranca Morselli; Frederick M. Laing; Neil K. Huyler; James W. Marvin

    1977-01-01

    A study of the engineering and economic effects of heat exchangers in conventional maple syrup evaporators indicated that: (1) Efficiency was increased by 15 to 17 percent with heat exchangers; (2) Syrup produced in evaporators with heat exchangers was similar to syrup produced in conventional systems in flavor and in chemical and physical composition; and (3) Heat...

  3. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers

    NASA Astrophysics Data System (ADS)

    Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.

    2017-01-01

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.

  4. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers.

    PubMed

    Tu, Y D; Wang, R Z; Ge, T S; Zheng, X

    2017-01-12

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump's efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.

  5. Secondary Heat Exchanger Design and Comparison for Advanced High Temperature Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piyush Sabharwall; Ali Siahpush; Michael McKellar

    2012-06-01

    The goals of next generation nuclear reactors, such as the high temperature gas-cooled reactor and advance high temperature reactor (AHTR), are to increase energy efficiency in the production of electricity and provide high temperature heat for industrial processes. The efficient transfer of energy for industrial applications depends on the ability to incorporate effective heat exchangers between the nuclear heat transport system and the industrial process heat transport system. The need for efficiency, compactness, and safety challenge the boundaries of existing heat exchanger technology, giving rise to the following study. Various studies have been performed in attempts to update the secondarymore » heat exchanger that is downstream of the primary heat exchanger, mostly because its performance is strongly tied to the ability to employ more efficient conversion cycles, such as the Rankine super critical and subcritical cycles. This study considers two different types of heat exchangers—helical coiled heat exchanger and printed circuit heat exchanger—as possible options for the AHTR secondary heat exchangers with the following three different options: (1) A single heat exchanger transfers all the heat (3,400 MW(t)) from the intermediate heat transfer loop to the power conversion system or process plants; (2) Two heat exchangers share heat to transfer total heat of 3,400 MW(t) from the intermediate heat transfer loop to the power conversion system or process plants, each exchanger transfers 1,700 MW(t) with a parallel configuration; and (3) Three heat exchangers share heat to transfer total heat of 3,400 MW(t) from the intermediate heat transfer loop to the power conversion system or process plants. Each heat exchanger transfers 1,130 MW(t) with a parallel configuration. A preliminary cost comparison will be provided for all different cases along with challenges and recommendations.« less

  6. Localized mold heating with the aid of selective induction for injection molding of high aspect ratio micro-features

    NASA Astrophysics Data System (ADS)

    Park, Keun; Lee, Sang-Ik

    2010-03-01

    High-frequency induction is an efficient, non-contact means of heating the surface of an injection mold through electromagnetic induction. Because the procedure allows for the rapid heating and cooling of mold surfaces, it has been recently applied to the injection molding of thin-walled parts or micro/nano-structures. The present study proposes a localized heating method involving the selective use of mold materials to enhance the heating efficiency of high-frequency induction heating. For localized induction heating, a composite injection mold of ferromagnetic material and paramagnetic material is used. The feasibility of the proposed heating method is investigated through numerical analyses in terms of its heating efficiency for localized mold surfaces and in terms of the structural safety of the composite mold. The moldability of high aspect ratio micro-features is then experimentally compared under a variety of induction heating conditions.

  7. Efficiency of health care system at the sub-state level in Madhya Pradesh, India.

    PubMed

    Purohit, Brijesh C

    2010-01-01

    This paper attempts a sub-state-level analysis of health system for a low-income Indian state, namely, Madhya Pradesh. The objective of our study is to establish efficiency parameters that may help health policy makers to improve district-level and thus state-level health system performance. It provides an idealized yardstick to evaluate the performance of the health sector by using stochastic frontier technique. The study was carried out in two stages of estimation, and our results suggest that life expectancy in the Indian state could be enhanced considerably by correcting the factors that are adversely influencing sub-state-level health system efficiency. Our results indicate that main factors within the health system for discrepancy in interdistrict performance are inequitable distribution of supplies, availability of skilled attention at birth, and inadequate staffing relative to patient load of rural population at primary health centers. Overcoming these factors through additional resources in the deficient districts, mobilized partly from grants in aid and partly from patient welfare societies, may help the state to improve life expectancy speedily and more equitably. Besides the direct inputs from the health sector, a more conducive environment for gender development, reducing inequality in opportunities for women in health, education and other rights may provide the necessary impetus towards reducing maternal morbidity and mortality and add to overall life expectancy in the state.

  8. Using microwave heating to improve the desorption efficiency of high molecular weight VOC from beaded activated carbon.

    PubMed

    Fayaz, Mohammadreza; Shariaty, Pooya; Atkinson, John D; Hashisho, Zaher; Phillips, John H; Anderson, James E; Nichols, Mark

    2015-04-07

    Incomplete regeneration of activated carbon loaded with organic compounds results in heel build-up that reduces the useful life of the adsorbent. In this study, microwave heating was tested as a regeneration method for beaded activated carbon (BAC) loaded with n-dodecane, a high molecular weight volatile organic compound. Energy consumption and desorption efficiency for microwave-heating regeneration were compared with conductive-heating regeneration. The minimum energy needed to completely regenerate the adsorbent (100% desorption efficiency) using microwave regeneration was 6% of that needed with conductive heating regeneration, owing to more rapid heating rates and lower heat loss. Analyses of adsorbent pore size distribution and surface chemistry confirmed that neither heating method altered the physical/chemical properties of the BAC. Additionally, gas chromatography (with flame ionization detector) confirmed that neither regeneration method detectably altered the adsorbate composition during desorption. By demonstrating improvements in energy consumption and desorption efficiency and showing stable adsorbate and adsorbent properties, this paper suggests that microwave heating is an attractive method for activated carbon regeneration particularly when high-affinity VOC adsorbates are present.

  9. The equivalence of minimum entropy production and maximum thermal efficiency in endoreversible heat engines.

    PubMed

    Haseli, Y

    2016-05-01

    The objective of this study is to investigate the thermal efficiency and power production of typical models of endoreversible heat engines at the regime of minimum entropy generation rate. The study considers the Curzon-Ahlborn engine, the Novikov's engine, and the Carnot vapor cycle. The operational regimes at maximum thermal efficiency, maximum power output and minimum entropy production rate are compared for each of these engines. The results reveal that in an endoreversible heat engine, a reduction in entropy production corresponds to an increase in thermal efficiency. The three criteria of minimum entropy production, the maximum thermal efficiency, and the maximum power may become equivalent at the condition of fixed heat input.

  10. Novikov Engine with Fluctuating Heat Bath Temperature

    NASA Astrophysics Data System (ADS)

    Schwalbe, Karsten; Hoffmann, Karl Heinz

    2018-04-01

    The Novikov engine is a model for heat engines that takes the irreversible character of heat fluxes into account. Using this model, the maximum power output as well as the corresponding efficiency of the heat engine can be deduced, leading to the well-known Curzon-Ahlborn efficiency. The classical model assumes constant heat bath temperatures, which is not a reasonable assumption in the case of fluctuating heat sources. Therefore, in this article the influence of stochastic fluctuations of the hot heat bath's temperature on the optimal performance measures is investigated. For this purpose, a Novikov engine with fluctuating heat bath temperature is considered. Doing so, a generalization of the Curzon-Ahlborn efficiency is found. The results can help to quantify how the distribution of fluctuating quantities affects the performance measures of power plants.

  11. Estimation of low-potential heat recuperation efficiency of smoke fumes in a condensation heat utilizer under various operation conditions of a boiler and a heating system

    NASA Astrophysics Data System (ADS)

    Ionkin, I. L.; Ragutkin, A. V.; Luning, B.; Zaichenko, M. N.

    2016-06-01

    For enhancement of the natural gas utilization efficiency in boilers, condensation heat utilizers of low-potential heat, which are constructed based on a contact heat exchanger, can be applied. A schematic of the contact heat exchanger with a humidifier for preheating and humidifying of air supplied in the boiler for combustion is given. Additional low-potential heat in this scheme is utilized for heating of the return delivery water supplied from a heating system. Preheating and humidifying of air supplied for combustion make it possible to use the condensation utilizer for heating of a heat-transfer agent to temperature exceeding the dewpoint temperature of water vapors contained in combustion products. The decision to mount the condensation heat utilizer on the boiler was taken based on the preliminary estimation of the additionally obtained heat. The operation efficiency of the condensation heat utilizer is determined by its structure and operation conditions of the boiler and the heating system. The software was developed for the thermal design of the condensation heat utilizer equipped by the humidifier. Computation investigations of its operation are carried out as a function of various operation parameters of the boiler and the heating system (temperature of the return delivery water and smoke fumes, air excess, air temperature at the inlet and outlet of the condensation heat utilizer, heating and humidifying of air in the humidifier, and portion of the circulating water). The heat recuperation efficiency is estimated for various operation conditions of the boiler and the condensation heat utilizer. Recommendations on the most effective application of the condensation heat utilizer are developed.

  12. Developing HEAT Scores with H-Res Thermal Imagery to Support Urban Energy Efficiency

    NASA Astrophysics Data System (ADS)

    Hemachandran, Bharanidharan

    As part of The Calgary Community GHG Reduction Plan (2009) The City is seeking an implementation strategy to reduce GHGs and promote low-carbon living, with a focus on improving urban energy efficiency. The most cited obstacle to energy efficiency improvements is the lack of interest from consumers (CUI, 2008). However, Darby (2006) has shown that effective feedback significantly reduces energy consumption. To exploit these findings, the HEAT (Heat Energy Assessment Technologies) Geoweb project integrates high-resolution (H-Res) airborne thermal imagery (TABI 1800) to provide unique energy efficiency feedback to Calgary homeowners in the form of interactive HEAT Maps and Hot Spots (Hay et al., 2011). As a part of the HEAT Phase II program, the goal of this research is to provide enhanced feedback support for urban energy efficiency by meeting two key objectives: (i) develop an appropriate method to define HEAT Scores using TABI 1800 imagery that allows for the comparison of waste heat of one or more houses with all other mapped houses in the community and city, and (ii) develop a multi-scale interactive Geoweb interface that displays the HEAT Scores at City, Community and Residential scales. To achieve these goals, we describe the evolution of three novel HEAT Score techniques based on: (i) a Standardized Score, (ii) the WUFIRTM model and Logistic Regression and (iii ) a novel criteria weighted method that considers: (a) heat transfer through different roofing materials, (b) local climatic conditions and (c) house age and living area attributes. Furthermore, (d) removing or adding houses to analysis based on this 3rd technique, does not affect the HEAT Score of other houses and (e) HEAT Scores can be compared within and across different cities. We also describe how HEAT Scores are incorporated within the HEAT Geoweb architecture. It is envisioned that HEAT Scores will promote energy efficiency among homeowners and urban city planners, as they will quantify and visualize invisible waste heat, and provide a public comparison of urban energy efficiency at the scale of homes, communities and cities. Analysis is conducted on 9279 houses in 12 communities over the SW quadrant of The City of Calgary and their results are publically available for comparison at www.saveheat.co.

  13. The maximum efficiency of nano heat engines depends on more than temperature

    NASA Astrophysics Data System (ADS)

    Woods, Mischa; Ng, Nelly; Wehner, Stephanie

    Sadi Carnot's theorem regarding the maximum efficiency of heat engines is considered to be of fundamental importance in the theory of heat engines and thermodynamics. Here, we show that at the nano and quantum scale, this law needs to be revised in the sense that more information about the bath other than its temperature is required to decide whether maximum efficiency can be achieved. In particular, we derive new fundamental limitations of the efficiency of heat engines at the nano and quantum scale that show that the Carnot efficiency can only be achieved under special circumstances, and we derive a new maximum efficiency for others. A preprint can be found here arXiv:1506.02322 [quant-ph] Singapore's MOE Tier 3A Grant & STW, Netherlands.

  14. Michigan sub-state area long range plans : final summary report

    DOT National Transportation Integrated Search

    1995-09-01

    Extensive change will mark the future of transportation in Michigan. To meet this challenge, the Michigan Department of Transportation (M.DOT) embarked upon the creation of a statewide plan to chart improvements to the transportation system and to de...

  15. 76 FR 35874 - Union Electric Company (dba Ameren Missouri); Notice of Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-20

    ... generators with a total installed capacity of 408 megawatts; (5) an excavated tailrace and open channel to the lower reservoir; (6) a 138-kilovolt switchyard/ substation; (7) a gravel and sedimentation trap...

  16. 51. LOOKING NORTHEAST AT EIMCO WASTE WATER TREATMENT THICKENER No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. LOOKING NORTHEAST AT EIMCO WASTE WATER TREATMENT THICKENER No. 2, ELECTRIC POWERHOUSE No. 2, AND OUTDOOR ELECTRICAL SUBSTATION IN BACKGROUND. (Jet Lowe) - U.S. Steel Duquesne Works, Blast Furnace Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  17. 7. SECOND FLOOR, EAST SIDE OF BUILDING LOOKING SOUTHEAST, AREA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. SECOND FLOOR, EAST SIDE OF BUILDING LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR

  18. 1. ENVIRONMENT, FROM NORTHWEST, SHOWING B&P INTERLOCKING TOWER AND POWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. ENVIRONMENT, FROM NORTHWEST, SHOWING B&P INTERLOCKING TOWER AND POWER SUBSTATIONS - Baltimore & Potomac Interlocking Tower, Adjacent to AMTRAK railroad tracks in block bounded by Howard Street, Jones Falls Expressway, Maryland Avenue & Falls Road, Baltimore, Independent City, MD

  19. 76 FR 48853 - FFP Project 70, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-09

    ...-up transformer and high-side and low-side disconnects; (8) a 900-foot-long, 161-kilovolt (kV) transmission line connecting the substation to Ameren UE's existing infrastructure; and (9) appurtenant...

  20. 76 FR 16766 - ECOsponsible, Inc.; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... feasibility of the Niagara River Community Hydro Project 2 (Niagara 2 Project or project) to be located on the... electricity to an onshore collection substation and point of interconnection switchyard; (3) an operations and...

  1. An assessment of efficient water heating options for an all-electric single family residence in a mixed-humid climate.

    PubMed

    Balke, Elizabeth C; Healy, William M; Ullah, Tania

    2016-12-01

    An evaluation of a variety of efficient water heating strategies for an all-electric single family home located in a mixed-humid climate is conducted using numerical modeling. The strategies considered include various combinations of solar thermal, heat pump, and electric resistance water heaters. The numerical model used in the study is first validated against a year of field data obtained on a dual-tank system with a solar thermal preheat tank feeding a heat pump water heater that serves as a backup. Modeling results show that this configuration is the most efficient of the systems studied over the course of a year, with a system coefficient of performance (COP sys ) of 2.87. The heat pump water heater alone results in a COP sys of 1.9, while the baseline resistance water heater has a COP sys of 0.95. Impacts on space conditioning are also investigated by considering the extra energy consumption required of the air source heat pump to remove or add heat from the conditioned space by the water heating system. A modified COP sys that incorporates the heat pump energy consumption shows a significant drop in efficiency for the dual tank configuration since the heat pump water heater draws the most heat from the space in the heating season while the high temperatures in the solar storage tank during the cooling season result in an added heat load to the space. Despite this degradation in the COP sys , the combination of the solar thermal preheat tank and the heat pump water heater is the most efficient option even when considering the impacts on space conditioning.

  2. An assessment of efficient water heating options for an all-electric single family residence in a mixed-humid climate

    PubMed Central

    Balke, Elizabeth C.; Healy, William M.; Ullah, Tania

    2016-01-01

    An evaluation of a variety of efficient water heating strategies for an all-electric single family home located in a mixed-humid climate is conducted using numerical modeling. The strategies considered include various combinations of solar thermal, heat pump, and electric resistance water heaters. The numerical model used in the study is first validated against a year of field data obtained on a dual-tank system with a solar thermal preheat tank feeding a heat pump water heater that serves as a backup. Modeling results show that this configuration is the most efficient of the systems studied over the course of a year, with a system coefficient of performance (COPsys) of 2.87. The heat pump water heater alone results in a COPsys of 1.9, while the baseline resistance water heater has a COPsys of 0.95. Impacts on space conditioning are also investigated by considering the extra energy consumption required of the air source heat pump to remove or add heat from the conditioned space by the water heating system. A modified COPsys that incorporates the heat pump energy consumption shows a significant drop in efficiency for the dual tank configuration since the heat pump water heater draws the most heat from the space in the heating season while the high temperatures in the solar storage tank during the cooling season result in an added heat load to the space. Despite this degradation in the COPsys, the combination of the solar thermal preheat tank and the heat pump water heater is the most efficient option even when considering the impacts on space conditioning. PMID:27990058

  3. Estimation procedure of the efficiency of the heat network segment

    NASA Astrophysics Data System (ADS)

    Polivoda, F. A.; Sokolovskii, R. I.; Vladimirov, M. A.; Shcherbakov, V. P.; Shatrov, L. A.

    2017-07-01

    An extensive city heat network contains many segments, and each segment operates with different efficiency of heat energy transfer. This work proposes an original technical approach; it involves the evaluation of the energy efficiency function of the heat network segment and interpreting of two hyperbolic functions in the form of the transcendental equation. In point of fact, the problem of the efficiency change of the heat network depending on the ambient temperature was studied. Criteria dependences used for evaluation of the set segment efficiency of the heat network and finding of the parameters for the most optimal control of the heat supply process of the remote users were inferred with the help of the functional analysis methods. Generally, the efficiency function of the heat network segment is interpreted by the multidimensional surface, which allows illustrating it graphically. It was shown that the solution of the inverse problem is possible as well. Required consumption of the heating agent and its temperature may be found by the set segment efficient and ambient temperature; requirements to heat insulation and pipe diameters may be formulated as well. Calculation results were received in a strict analytical form, which allows investigating the found functional dependences for availability of the extremums (maximums) under the set external parameters. A conclusion was made that it is expedient to apply this calculation procedure in two practically important cases: for the already made (built) network, when the change of the heat agent consumption and temperatures in the pipe is only possible, and for the projecting (under construction) network, when introduction of changes into the material parameters of the network is possible. This procedure allows clarifying diameter and length of the pipes, types of insulation, etc. Length of the pipes may be considered as the independent parameter for calculations; optimization of this parameter is made in accordance with other, economical, criteria for the specific project.

  4. Study on heat pipe assisted thermoelectric power generation system from exhaust gas

    NASA Astrophysics Data System (ADS)

    Chi, Ri-Guang; Park, Jong-Chan; Rhi, Seok-Ho; Lee, Kye-Bock

    2017-11-01

    Currently, most fuel consumed by vehicles is released to the environment as thermal energy through the exhaust pipe. Environmentally friendly vehicle technology needs new methods to increase the recycling efficiency of waste exhaust thermal energy. The present study investigated how to improve the maximum power output of a TEG (Thermoelectric generator) system assisted with a heat pipe. Conventionally, the driving energy efficiency of an internal combustion engine is approximately less than 35%. TEG with Seebeck elements is a new idea for recycling waste exhaust heat energy. The TEG system can efficiently utilize low temperature waste heat, such as industrial waste heat and solar energy. In addition, the heat pipe can transfer heat from the automobile's exhaust gas to a TEG. To improve the efficiency of the thermal power generation system with a heat pipe, effects of various parameters, such as inclination angle, charged amount of the heat pipe, condenser temperature, and size of the TEM (thermoelectric element), were investigated. Experimental studies, CFD simulation, and the theoretical approach to thermoelectric modules were carried out, and the TEG system with heat pipe (15-20% charged, 20°-30° inclined configuration) showed the best performance.

  5. Review on Microwave-Matter Interaction Fundamentals and Efficient Microwave-Associated Heating Strategies

    PubMed Central

    Sun, Jing; Wang, Wenlong; Yue, Qinyan

    2016-01-01

    Microwave heating is rapidly emerging as an effective and efficient tool in various technological and scientific fields. A comprehensive understanding of the fundamentals of microwave–matter interactions is the precondition for better utilization of microwave technology. However, microwave heating is usually only known as dielectric heating, and the contribution of the magnetic field component of microwaves is often ignored, which, in fact, contributes greatly to microwave heating of some aqueous electrolyte solutions, magnetic dielectric materials and certain conductive powder materials, etc. This paper focuses on this point and presents a careful review of microwave heating mechanisms in a comprehensive manner. Moreover, in addition to the acknowledged conventional microwave heating mechanisms, the special interaction mechanisms between microwave and metal-based materials are attracting increasing interest for a variety of metallurgical, plasma and discharge applications, and therefore are reviewed particularly regarding the aspects of the reflection, heating and discharge effects. Finally, several distinct strategies to improve microwave energy utilization efficiencies are proposed and discussed with the aim of tackling the energy-efficiency-related issues arising from the application of microwave heating. This work can present a strategic guideline for the developed understanding and utilization of the microwave heating technology. PMID:28773355

  6. Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016

    NASA Astrophysics Data System (ADS)

    Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas

    2017-06-01

    A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.

  7. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of commercial air conditioners and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... efficiency of commercial air conditioners and heat pumps. 431.96 Section 431.96 Energy DEPARTMENT OF ENERGY... Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps. (a) Scope. This section contains test...

  8. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of commercial air conditioners and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... efficiency of commercial air conditioners and heat pumps. 431.96 Section 431.96 Energy DEPARTMENT OF ENERGY... Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the measurement of energy efficiency of commercial air conditioners and heat pumps. (a) Scope. This section contains test...

  9. Geometric Heat Engines Featuring Power that Grows with Efficiency.

    PubMed

    Raz, O; Subaşı, Y; Pugatch, R

    2016-04-22

    Thermodynamics places a limit on the efficiency of heat engines, but not on their output power or on how the power and efficiency change with the engine's cycle time. In this Letter, we develop a geometrical description of the power and efficiency as a function of the cycle time, applicable to an important class of heat engine models. This geometrical description is used to design engine protocols that attain both the maximal power and maximal efficiency at the fast driving limit. Furthermore, using this method, we also prove that no protocol can exactly attain the Carnot efficiency at nonzero power.

  10. The efficiency of combustion turbines with constant-pressure combustion

    NASA Technical Reports Server (NTRS)

    Piening, Werner

    1941-01-01

    Of the two fundamental cycles employed in combustion turbines, namely, the explosion (or constant-volume) cycle and the constant-pressure cycle, the latter is considered more in detail and its efficiency is derived with the aid of the cycle diagrams for the several cases with adiabatic and isothermal compression and expansion strokes and with and without utilization of the exhaust heat. Account is also taken of the separate efficiencies of the turbine and compressor and of the pressure losses and heat transfer in the piping. The results show that without the utilization of the exhaust heat the efficiencies for the two cases of adiabatic and isothermal compression is offset by the increase in the heat supplied. It may be seen from the curves that it is necessary to attain separate efficiencies of at least 80 percent in order for useful results to be obtained. There is further shown the considerable effect on the efficiency of pressure losses in piping or heat exchangers.

  11. Heat Shock-Enhanced Conjugation Efficiency in Standard Campylobacter jejuni Strains

    PubMed Central

    Zeng, Ximin; Ardeshna, Devarshi

    2015-01-01

    Campylobacter jejuni, the leading bacterial cause of human gastroenteritis in the United States, displays significant strain diversity due to horizontal gene transfer. Conjugation is an important horizontal gene transfer mechanism contributing to the evolution of bacterial pathogenesis and antimicrobial resistance. It has been observed that heat shock could increase transformation efficiency in some bacteria. In this study, the effect of heat shock on C. jejuni conjugation efficiency and the underlying mechanisms were examined. With a modified Escherichia coli donor strain, different C. jejuni recipient strains displayed significant variation in conjugation efficiency ranging from 6.2 × 10−8 to 6.0 × 10−3 CFU per recipient cell. Despite reduced viability, heat shock of standard C. jejuni NCTC 11168 and 81-176 strains (e.g., 48 to 54°C for 30 to 60 min) could dramatically enhance C. jejuni conjugation efficiency up to 1,000-fold. The phenotype of the heat shock-enhanced conjugation in C. jejuni recipient cells could be sustained for at least 9 h. Filtered supernatant from the heat shock-treated C. jejuni cells could not enhance conjugation efficiency, which suggests that the enhanced conjugation efficiency is independent of secreted substances. Mutagenesis analysis indicated that the clustered regularly interspaced short palindromic repeats system and the selected restriction-modification systems (Cj0030/Cj0031, Cj0139/Cj0140, Cj0690c, and HsdR) were dispensable for heat shock-enhanced conjugation in C. jejuni. Taking all results together, this study demonstrated a heat shock-enhanced conjugation efficiency in standard C. jejuni strains, leading to an optimized conjugation protocol for molecular manipulation of this organism. The findings from this study also represent a significant step toward elucidation of the molecular mechanism of conjugative gene transfer in C. jejuni. PMID:25911489

  12. Heat Shock-Enhanced Conjugation Efficiency in Standard Campylobacter jejuni Strains.

    PubMed

    Zeng, Ximin; Ardeshna, Devarshi; Lin, Jun

    2015-07-01

    Campylobacter jejuni, the leading bacterial cause of human gastroenteritis in the United States, displays significant strain diversity due to horizontal gene transfer. Conjugation is an important horizontal gene transfer mechanism contributing to the evolution of bacterial pathogenesis and antimicrobial resistance. It has been observed that heat shock could increase transformation efficiency in some bacteria. In this study, the effect of heat shock on C. jejuni conjugation efficiency and the underlying mechanisms were examined. With a modified Escherichia coli donor strain, different C. jejuni recipient strains displayed significant variation in conjugation efficiency ranging from 6.2 × 10(-8) to 6.0 × 10(-3) CFU per recipient cell. Despite reduced viability, heat shock of standard C. jejuni NCTC 11168 and 81-176 strains (e.g., 48 to 54°C for 30 to 60 min) could dramatically enhance C. jejuni conjugation efficiency up to 1,000-fold. The phenotype of the heat shock-enhanced conjugation in C. jejuni recipient cells could be sustained for at least 9 h. Filtered supernatant from the heat shock-treated C. jejuni cells could not enhance conjugation efficiency, which suggests that the enhanced conjugation efficiency is independent of secreted substances. Mutagenesis analysis indicated that the clustered regularly interspaced short palindromic repeats system and the selected restriction-modification systems (Cj0030/Cj0031, Cj0139/Cj0140, Cj0690c, and HsdR) were dispensable for heat shock-enhanced conjugation in C. jejuni. Taking all results together, this study demonstrated a heat shock-enhanced conjugation efficiency in standard C. jejuni strains, leading to an optimized conjugation protocol for molecular manipulation of this organism. The findings from this study also represent a significant step toward elucidation of the molecular mechanism of conjugative gene transfer in C. jejuni. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. Analysis of the efficiency of a hybrid foil tunnel heating system

    NASA Astrophysics Data System (ADS)

    Kurpaska, Sławomir; Pedryc, Norbert

    2017-10-01

    The paper analyzes the efficiency of the hybrid system used to heat the foil tunnel. The tested system was built on the basis of heat gain in a cascade manner. The first step is to heat the water in the storage tank using the solar collectors. The second stage is the use of a heat pump (HP) in order to heat the diaphragm exchangers. The lower HP heat source is a cascade first stage buffer. In the storage tank, diaphragm exchangers used for solar collectors and heat pumps are installed. The research was carried out at a research station located in the University of Agriculture in Cracow. The aim was to perform an analysis of the efficiency of a hybrid system for the heating of a foil tunnel in the months from May to September. The efficiency of the entire hybrid system was calculated as the relation of the effect obtained in reference to the electrical power used to drive the heat pump components (compressor drive, circulation pump), circulation pumps and fans installed in the diaphragm heaters. The resulting effect was the amount of heat supplied to the interior of the object as a result of the internal air being forced through the diaphragm exchangers.

  14. Efficiency of some heat engines at maximum-power conditions

    NASA Astrophysics Data System (ADS)

    De Vos, Alexis

    1985-06-01

    In the present paper a simple model is presented for a heat engine, where the power output is limited by the rate of heat supply (and/or heat release). The model leads to a variety of results. Some of them are established laws such as the Carnot law, the Curzon-Ahlborn efficiency, and the Castañs efficiency. Other results are new, and are related to phenomena as different as geothermal energy conversion and the Penfield paradox of electric circuits.

  15. Mounting for diodes provides efficient heat sink

    NASA Technical Reports Server (NTRS)

    1964-01-01

    Efficient heat sink is provided by soldering diodes to metal support bars which are brazed to a ceramic base. Electrical connections between diodes on adjacent bars are made flexible by metal strips which aid in heat dissipation.

  16. Improving urban district heating systems and assessing the efficiency of the energy usage therein

    NASA Astrophysics Data System (ADS)

    Orlov, M. E.; Sharapov, V. I.

    2017-11-01

    The report describes issues in connection with improving urban district heating systems from combined heat power plants (CHPs), to propose the ways for improving the reliability and the efficiency of the energy usage (often referred to as “energy efficiency”) in such systems. The main direction of such urban district heating systems improvement suggests transition to combined heating systems that include structural elements of both centralized and decentralized systems. Such systems provide the basic part of thermal power via highly efficient methods for extracting thermal power plants turbines steam, while peak loads are covered by decentralized peak thermal power sources to be mounted at consumers’ locations, with the peak sources being also reserve thermal power sources. The methodology was developed for assessing energy efficiency of the combined district heating systems, implemented as a computer software product capable of comparatively calculating saving on reference fuel for the system.

  17. Design and simulation of a novel high-efficiency cooling heat-sink structure using fluid-thermodynamics

    NASA Astrophysics Data System (ADS)

    Hongqi, Jing; Li, Zhong; Yuxi, Ni; Junjie, Zhang; Suping, Liu; Xiaoyu, Ma

    2015-10-01

    A novel high-efficiency cooling mini-channel heat-sink structure has been designed to meet the package technology demands of high power density laser diode array stacks. Thermal and water flowing characteristics have been simulated using the Ansys-Fluent software. Owing to the increased effective cooling area, this mini-channel heat-sink structure has a better cooling effect when compared with the traditional macro-channel heat-sinks. Owing to the lower flow velocity in this novel high efficient cooling structure, the chillers' water-pressure requirement is reduced. Meanwhile, the machining process of this high-efficiency cooling mini-channel heat-sink structure is simple and the cost is relatively low, it also has advantages in terms of high durability and long lifetime. This heat-sink is an ideal choice for the package of high power density laser diode array stacks. Project supported by the Defense Industrial Technology Development Program (No. B1320133033).

  18. Subsurface Thermal Energy Storage for Improved Heating and Air Conditioning Efficiency

    DTIC Science & Technology

    2016-11-21

    This project involved a field demonstration of subsurface thermal energy storage for improving the geothermal heat pump air conditioning efficiency... geothermal heat pump systems, undesirable heating of the ground may occur. This demonstration was performed at the MCAS, Beaufort, SC, where several...buildings with geothermal heat pump systems were exhibiting excessively high ground loop temperatures. These buildings were retrofitted with dry fluid

  19. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers

    PubMed Central

    Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.

    2017-01-01

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8–3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications. PMID:28079171

  20. 75 FR 13299 - Lower Colorado River Authority Transmission Services Corporation; Construction, Operation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-19

    ...] Lower Colorado River Authority Transmission Services Corporation; Construction, Operation, Maintenance... activities associated with LCRA TSC's construction, maintenance, operation, and repair of four Competitive..., substation upgrades, and access roads) required to be constructed by the Public Utility Commission of Texas...

  1. 76 FR 54752 - Union Electric Company (dba Ameren Missouri); Notice of Application Ready for Environmental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-02

    ... open channel to the lower reservoir; (6) a 138-kilovolt switchyard/ substation; (7) a gravel and sedimentation trap (bin wall) on the East Fork of the Black River; and (8) associated ancillary equipment. m. A...

  2. 7. Photocopy of Elevations drawing (from the BPA Engineering Vault, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photocopy of Elevations drawing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 3, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  3. Big Creek Hydroelectric System, East & West Transmission Line, 241mile ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Big Creek Hydroelectric System, East & West Transmission Line, 241-mile transmission corridor extending between the Big Creek Hydroelectric System in the Sierra National Forest in Fresno County and the Eagle Rock Substation in Los Angeles, California, Visalia, Tulare County, CA

  4. 76 FR 53437 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... a matrix on the bottom of the river; (2) the total capacity of the installation would be up to 35,000 kilowatts; (3) shielded underwater cables would convey each matrix power to a substation; and (4...

  5. 76 FR 53430 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14076-000 would consist of: (1) Up to 376 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  6. 76 FR 53435 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14089-000 would consist of: (1) Up to 260 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  7. 76 FR 53436 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14091-000 would consist of: (1) Up to 400 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  8. 76 FR 53443 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... would consist of the following: (1) Up to 120 TREK generating units installed in a matrix on the bottom...) shielded underwater cables would convey each matrix power to a substation; and (4) a transmission line...

  9. 76 FR 53434 - Free Flow Power Corporation, Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...) Up to 160 TREK generating units installed in a matrix on the bottom of the river; (2) the total... each matrix power to a substation; and (4) a transmission line would interconnect with the power grid...

  10. 76 FR 53433 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...-000 would consist of: (1) Up to 400 TREK generating units installed in a matrix on the bottom of the... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  11. 76 FR 53436 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14090-000 would consist of: (1) Up to 200 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix's power to a substation; and (4) a transmission line would...

  12. 76 FR 53427 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14074-000 would consist of: (1) Up to 376 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  13. 76 FR 53438 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14081-000 would consist of: (1) Up to 50 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  14. 76 FR 53434 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14093-000 would consist of: (1) Up to 160 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  15. 76 FR 53431 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14072-000 would consist of: (1) Up to 150 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  16. 76 FR 53443 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... of the following: (1) Up to 75 TREK generating units installed in a matrix on the bottom of the river... cables would convey each matrix power to a substation; and (4) a transmission line would interconnect...

  17. 76 FR 53427 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14092-000 would consist of: (1) Up to 180 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  18. 76 FR 53432 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14099-000 would consist of: (1) Up to 380 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  19. 76 FR 53438 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14096-000 would consist of: (1) Up to 340 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  20. Electrical Equipment of Electrical Stations and Substations,

    DTIC Science & Technology

    1979-10-25

    of Communist society. In 1921 he wrote: "fhe sole material base of socialism can be the large/coarse machine industry, capable of reorganizing and...produced with the aid of special switching system, structurally/ constructionally being part transformer itself. The transformers, supplied with this

  1. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF....107 Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters...

  2. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF....107 Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters...

  3. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF....107 Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters...

  4. Utilizing Radioisotope Power System Waste Heat for Spacecraft Thermal Management

    NASA Technical Reports Server (NTRS)

    Pantano, David R.; Dottore, Frank; Geng, Steven M.; Schrieber, Jeffrey G.; Tobery, E. Wayne; Palko, Joseph L.

    2005-01-01

    One of the advantages of using a Radioisotope Power System (RPS) for deep space or planetary surface missions is the readily available waste heat, which can be used to maintain electronic components within a controlled temperature range, to warm propulsion tanks and mobility actuators, and to gasify liquid propellants. Previous missions using Radioisotope Thermoelectric Generators (RTGs) dissipated a very large quantity of waste heat due to the relatively low efficiency of the thermoelectric conversion technology. The next generation RPSs, such as the 110-watt Stirling Radioisotope Generator (SRG110) will have much higher conversion efficiencies than their predecessors and therefore may require alternate approaches to transferring waste heat to the spacecraft. RTGs, with efficiencies of approx. 6 to 7% and 200 C housing surface temperatures, would need to use large and heavy radiator heat exchangers to transfer the waste heat to the internal spacecraft components. At the same time, sensitive spacecraft instruments must be shielded from the thermal radiation by using the heat exchangers or additional shields. The SRG110, with an efficiency around 22% and 50 C nominal housing surface temperature, can use the available waste heat more efficiently by more direct heat transfer methods such as heat pipes, thermal straps, or fluid loops. The lower temperatures allow the SRG110 much more flexibility to the spacecraft designers in configuring the generator without concern of overheating nearby scientific instruments, thereby eliminating the need for thermal shields. This paper will investigate using a high efficiency SRG110 for spacecraft thermal management and outline potential methods in several conceptual missions (Lunar Rover, Mars Rover, and Titan Lander) to illustrate the advantages with regard to ease of assembly, less complex interfaces, and overall mass savings.

  5. Design and Development of a Residential Gas-Fired Heat Pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vineyard, Edward Allan; Abu-Heiba, Ahmad; Mahderekal, Dr. Isaac

    2017-01-01

    Heating, ventilating, and air-conditioning equipment consumes 43% of the total primary energy consumption in U.S. households. Presently, conventional gas furnaces have maximum heating efficiencies of 98%. Electric air conditioners used in association with the furnace for cooling have a minimum seasonal energy efficiency ratio (SEER) of 14.0. A residential gas-fired heat pump (RGHP) was developed and tested under standard rating conditions, resulting in a significant increase in heating efficiency of over 40% versus conventional natural gas furnaces. The associated efficiency of the RGHP in cooling mode is comparable in efficiency to an electric air conditioner (14.0 SEER) when compared onmore » a primary energy basis. The RGHP is similar in nature to a conventional heat pump but with two main differences. First, the primary energy savings are higher, based on a site versus source comparison, as the result of using natural gas to supply shaft power to the compressor rather than an electric motor. Second, waste heat is recovered from the engine to supplement space heating and reduce the energy input. It can also be used to provide supplemental water heating. The system utilizes a programmable logic controller that allows variable-speed operation to achieve improved control to meet building loads. RGHPs significantly reduce peak electric use during periods of high demand, especially peak summer loads, as well as peak winter loads in regions with widespread use of electric heating. This contributes to leveling year-round gas loads, with the potential to increase annual gas demand in some regions. The widespread adoption of RGHPs will contribute to significant reductions in primary energy consumption and carbon emissions through improved efficiencies.« less

  6. Giant K-doubling and in-plane/out-of-plane mixing in the asymmetric methyl-bending bands of CH3SH

    NASA Astrophysics Data System (ADS)

    Guislain, B. G.; Reid, E. M.; Lees, R. M.; Xu, Li-Hong; Twagirayezu, S.; Perry, D. S.; Thapaliya, B. P.; Dawadi, M. B.; Billinghurst, B. E.

    2017-05-01

    In analyzing high-resolution spectra of the methyl-deformation bands of methyl mercaptan recorded at the Canadian Light Source synchrotron, we have encountered interesting interactions between certain levels of the ν4 in-plane asymmetric CH3-bending mode and its ν10 out-of-plane bending partner below. The origin of the K = 0A ν4 substate is just 0.2 cm-1 higher than that of the K = 2A ν10 substate, while the K = 0E ν4 origin is only 0.035 cm-1 below the K = 2E ν10 origin. These very close accidental near-degeneracies lead to substantial perturbations in the spectrum. For the former, the A+/A- asymmetry K-doublet coupling rules are such that the A- component of the 2A ν10 doublet interacts and mixes strongly with the 0A+ ν4 levels whereas the 2A+ component is unaffected. The 2A- levels are pushed rapidly downwards by the coupling creating an extremely large apparent K = 2A asymmetry splitting. We call this "giant K-doubling" by analogy with a comparable phenomenon seen for methanol. The 0A+ ν4 state, in turn, is perturbed upward and passes through the descending K = 1A+ ν4 state between J = 22 and 23, leading to distinct local perturbations near the level-crossing. The 0E ν4 and 2E ν10 coupling produces a correspondingly strong repulsion and mixing between those two substates, and gives rise to a forbidden K = 0 ← 3E intermode sub-band in the spectrum via intensity borrowing.

  7. Giant K-doubling and in-plane/out-of-plane mixing in the asymmetric methyl-bending bands of CH 3SH

    DOE PAGES

    Guislain, B. G.; Reid, E. M.; Lees, R. M.; ...

    2017-03-02

    In analyzing high-resolution spectra of the methyl-deformation bands of methyl mercaptan recorded at the Canadian Light Source synchrotron, we have encountered interesting interactions between certain levels of the ν 4 in-plane asymmetric CH 3-bending mode and its ν 10 out-of-plane bending partner below. The origin of the K = 0A ν 4 substate is just 0.2 cm -1 higher than that of the K = 2A ν 10 substate, while the K = 0E ν 4 origin is only 0.035 cm -1 below the K = 2E ν 10 origin. These very close accidental near-degeneracies lead to substantial perturbations inmore » the spectrum. For the former, the A +/A - asymmetry K-doublet coupling rules are such that the A - component of the 2A ν 10 doublet interacts and mixes strongly with the 0A + ν 4 levels whereas the 2A + component is unaffected. The 2A - levels are pushed rapidly downwards by the coupling creating an extremely large apparent K = 2A asymmetry splitting. We call this “giant K-doubling” by analogy with a comparable phenomenon seen for methanol. The 0A + ν 4 state, in turn, is perturbed upward and passes through the descending K = 1A + ν 4 state between J = 22 and 23, leading to distinct local perturbations near the level-crossing. The 0E ν 4 and 2E ν 10 coupling produces a correspondingly strong repulsion and mixing between those two substates, and gives rise to a forbidden K = 0 ← 3E intermode sub-band in the spectrum via intensity borrowing.« less

  8. Giant K-doubling and in-plane/out-of-plane mixing in the asymmetric methyl-bending bands of CH 3SH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guislain, B. G.; Reid, E. M.; Lees, R. M.

    In analyzing high-resolution spectra of the methyl-deformation bands of methyl mercaptan recorded at the Canadian Light Source synchrotron, we have encountered interesting interactions between certain levels of the ν 4 in-plane asymmetric CH 3-bending mode and its ν 10 out-of-plane bending partner below. The origin of the K = 0A ν 4 substate is just 0.2 cm -1 higher than that of the K = 2A ν 10 substate, while the K = 0E ν 4 origin is only 0.035 cm -1 below the K = 2E ν 10 origin. These very close accidental near-degeneracies lead to substantial perturbations inmore » the spectrum. For the former, the A +/A - asymmetry K-doublet coupling rules are such that the A - component of the 2A ν 10 doublet interacts and mixes strongly with the 0A + ν 4 levels whereas the 2A + component is unaffected. The 2A - levels are pushed rapidly downwards by the coupling creating an extremely large apparent K = 2A asymmetry splitting. We call this “giant K-doubling” by analogy with a comparable phenomenon seen for methanol. The 0A + ν 4 state, in turn, is perturbed upward and passes through the descending K = 1A + ν 4 state between J = 22 and 23, leading to distinct local perturbations near the level-crossing. The 0E ν 4 and 2E ν 10 coupling produces a correspondingly strong repulsion and mixing between those two substates, and gives rise to a forbidden K = 0 ← 3E intermode sub-band in the spectrum via intensity borrowing.« less

  9. Phosphorylation of rat brain purified mitochondrial Voltage-Dependent Anion Channel by c-Jun N-terminal kinase-3 modifies open-channel noise.

    PubMed

    Gupta, Rajeev

    2017-09-02

    The drift kinetic energy of ionic flow through single ion channels cause vibrations of the pore walls which are observed as open-state current fluctuations (open-channel noise) during single-channel recordings. Vibration of the pore wall leads to transitions among different conformational sub-states of the channel protein in the open-state. Open-channel noise analysis can provide important information about the different conformational sub-state transitions and how biochemical modifications of ion channels would affect their transport properties. It has been shown that c-Jun N-terminal kinase-3 (JNK3) becomes activated by phosphorylation in various neurodegenerative diseases and phosphorylates outer mitochondrion associated proteins leading to neuronal apoptosis. In our earlier work, JNK3 has been reported to phosphorylate purified rat brain mitochondrial voltage-dependent anion channel (VDAC) in vitro and modify its conductance and opening probability. In this article we have compared the open-state noise profile of the native and the JNK3 phosphorylated VDAC using Power Spectral Density vs frequency plots. Power spectral density analysis of open-state noise indicated power law with average slope value α ≈1 for native VDAC at both positive and negative voltage whereas average α value < 0.5 for JNK3 phosphorylated VDAC at both positive and negative voltage. It is proposed that 1/f 1 power law in native VDAC open-state noise arises due to coupling of ionic transport and conformational sub-states transitions in open-state and this coupling is perturbed as a result of channel phosphorylation. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Occupational exposure to electric fields and induced currents associated with 400 kV substation tasks from different service platforms.

    PubMed

    Korpinen, Leena H; Elovaara, Jarmo A; Kuisti, Harri A

    2011-01-01

    The aim of the study was to investigate the occupational exposure to electric fields, average current densities, and average total contact currents at 400 kV substation tasks from different service platforms (main transformer inspection, maintenance of operating device of disconnector, maintenance of operating device of circuit breaker). The average values are calculated over measured periods (about 2.5 min). In many work tasks, the maximum electric field strengths exceeded the action values proposed in the EU Directive 2004/40/EC, but the average electric fields (0.2-24.5 kV/m) were at least 40% lower than the maximum values. The average current densities were 0.1-2.3 mA/m² and the average total contact currents 2.0-143.2 µA, that is, clearly less than the limit values of the EU Directive. The average values of the currents in head and contact currents were 16-68% lower than the maximum values when we compared the average value from all cases in the same substation. In the future it is important to pay attention to the fact that the action and limit values of the EU Directive differ significantly. It is also important to take into account that generally, the workers' exposure to the electric fields, current densities, and total contact currents are obviously lower if we use the average values from a certain measured time period (e.g., 2.5 min) than in the case where exposure is defined with only the help of the maximum values. © 2010 Wiley-Liss, Inc.

  11. Generation of a Parabolic Trough Collector Efficiency Curve from Separate Measurements of Outdoor Optical Efficiency and Indoor Receiver Heat Loss: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kutscher, C.; Burkholder, F.; Stynes, K.

    2010-10-01

    The overall efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The overall efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain an overall efficiency curve. Further, it presents a new way to plot efficiency that is more robust overmore » a range of receiver operating temperatures.« less

  12. Heat pump/refrigerator using liquid working fluid

    DOEpatents

    Wheatley, John C.; Paulson, Douglas N.; Allen, Paul C.; Knight, William R.; Warkentin, Paul A.

    1982-01-01

    A heat transfer device is described that can be operated as a heat pump or refrigerator, which utilizes a working fluid that is continuously in a liquid state and which has a high temperature-coefficient of expansion near room temperature, to provide a compact and high efficiency heat transfer device for relatively small temperature differences as are encountered in heating or cooling rooms or the like. The heat transfer device includes a pair of heat exchangers that may be coupled respectively to the outdoor and indoor environments, a regenerator connecting the two heat exchangers, a displacer that can move the liquid working fluid through the heat exchangers via the regenerator, and a means for alternately increasing and decreasing the pressure of the working fluid. The liquid working fluid enables efficient heat transfer in a compact unit, and leads to an explosion-proof smooth and quiet machine characteristic of hydraulics. The device enables efficient heat transfer as the indoor-outdoor temperature difference approaches zero, and enables simple conversion from heat pumping to refrigeration as by merely reversing the direction of a motor that powers the device.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  14. Utilizing Radioisotope Power System Waste Heat for Spacecraft Thermal Management

    NASA Technical Reports Server (NTRS)

    Pantano, David R.; Dottore, Frank; Tobery, E. Wayne; Geng, Steven M.; Schreiber, Jeffrey G.; Palko, Joseph L.

    2005-01-01

    An advantage of using a Radioisotope Power System (RPS) for deep space or planetary surface missions is the readily available waste heat, which can be used for a number of beneficial purposes including: maintaining electronic components within a controlled temperature range, warming propulsion tanks and mobility actuators, and maintaining liquid propellants above their freezing temperature. Previous missions using Radioisotope Thermoelectric Generators (RTGs) dissipated large quantities of waste heat due to the low efficiency of the thermoelectric conversion technology. The next generation RPSs, such as the 110-Watt Stirling Radioisotope Generator (SRG110) will have higher conversion efficiencies, thereby rejecting less waste heat at a lower temperature and may require alternate approaches to transferring waste heat to the spacecraft. RTGs, with efficiencies of 6 to 7 percent, reject their waste heat at the relatively high heat rejection temperature of 200 C. This is an advantage when rejecting heat to space; however, transferring heat to the internal spacecraft components requires a large and heavy radiator heat exchanger. At the same time, sensitive spacecraft instruments must be shielded from the thermal radiation of the RTG. The SRG110, with an efficiency around 22 percent and 50 C nominal housing surface temperature, can readily transfer the available waste heat directly via heat pipes, thermal straps, or fluid loops. The lower temperatures associated with the SRG110 avoid the chances of overheating other scientific components, eliminating the need for thermal shields. This provides the spacecraft designers more flexibility when locating the generator for a specific mission. A common misconception with high-efficiency systems is that there is not enough waste heat for spacecraft thermal management. This paper will dispel this misconception and investigate the use of a high-efficiency SRG110 for spacecraft thermal management and outline potential methods of waste heat utilization in several conceptual missions (Lunar Rover, Mars Rover, and Titan Lander). The advantages associated with the SRG110 as they relate to ease of assembly, less complex interfaces, and overall mass savings for a spacecraft will be highlighted.

  15. Modeling induction heater temperature distribution in polymeric material

    NASA Astrophysics Data System (ADS)

    Sorokin, A. G.; Filimonova, O. V.

    2017-10-01

    An induction heating system has a number of inherent benefits compared to traditional heating systems due to a non-contact heating process. The main interesting area of the induction heating process is the efficiency of the usage of energy, choice of the plate material and different coil configurations based on application. Correctly designed, manufactured and maintained induction coils are critical to the overall efficiency of induction heating solutions. The paper describes how the induction heating system in plastic injection molding is designed. The use of numerical simulation in order to get the optimum design of the induction coil is shown. The purpose of this work is to consider various coil configurations used in the induction heating process, which is widely used in plastic molding. Correctly designed, manufactured and maintained induction coils are critical to the overall efficiency of induction heating solutions. The results of calculation are in the numerical model.

  16. Conversion efficiency of an energy harvester based on resonant tunneling through quantum dots with heat leakage.

    PubMed

    Kano, Shinya; Fujii, Minoru

    2017-03-03

    We study the conversion efficiency of an energy harvester based on resonant tunneling through quantum dots with heat leakage. Heat leakage current from a hot electrode to a cold electrode is taken into account in the analysis of the harvester operation. Modeling of electrical output indicates that a maximum heat leakage current is not negligible because it is larger than that of the heat current harvested into electrical power. A reduction of heat leakage is required in this energy harvester in order to obtain efficient heat-to-electrical conversion. Multiple energy levels of a quantum dot can increase the output power of the harvester. Heavily doped colloidal semiconductor quantum dots are a possible candidate for a quantum-dot monolayer in the energy harvester to reduce heat leakage, scaling down device size, and increasing electrical output via multiple discrete energy levels.

  17. Development of a nonazeotropic heat pump for crew hygiene water heating

    NASA Technical Reports Server (NTRS)

    Walker, David H.; Deming, Glenn I.

    1991-01-01

    A heat pump system is currently under development to produce hot water for crew hygiene on future manned space missions. The heat pump uses waste heat sources and a nonazeotropic working fluid in a highly efficient cycle. The potential benefits include a reduction in peak power draw from 2 to 5 kW for electric cartridge heaters to just more than 100 W for the heat pump. As part of the heat pump development project, a unique high efficiency compressor was developed to maintain lubrication in a zero-gravity environment.

  18. Heat Pipes Reduce Engine-Exhaust Emissions

    NASA Technical Reports Server (NTRS)

    Schultz, D. F.

    1986-01-01

    Increased fuel vaporization raises engine efficiency. Heat-pipe technology increased efficiency of heat transfer beyond that obtained by metallic conduction. Resulted in both improved engine operation and reduction in fuel consumption. Raw material conservation through reduced dependence on strategic materials also benefit from this type of heat-pipe technology. Applications result in improved engine performance and cleaner environment.

  19. 20 CFR 631.19 - Appeals.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... training plans or modifications) shall apply to final disapproval of substate plans under § 631.50(f) of...' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR PROGRAMS UNDER TITLE III OF THE JOB TRAINING PARTNERSHIP ACT Additional Title III Administrative Standards and Procedures § 631.19 Appeals...

  20. 75 FR 39241 - Hooper Springs Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-08

    ... Power Administration (BPA), Department of Energy (DOE). ACTION: Notice of Intent to prepare an Environmental Impact Statement (EIS) and notice of floodplain and wetlands involvement. SUMMARY: BPA intends to... (collectively referred to as the Hooper Springs Project). The new BPA substation would be called Hooper Springs...

  1. 9. Photocopy of Reinforced Concrete Details drawing (from the BPA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Photocopy of Reinforced Concrete Details drawing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 6, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  2. 78 FR 60273 - Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild, Grand County...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    ... marketing administration in the U.S. Department of Energy (DOE), owns and operates the 69-kilovolt (kV... the project. No new sources of power would be needed for the project. The resource mix would not be...

  3. 2. ENVIRONMENT, FROM SOUTHEAST, SHOWING B&P INTERLOCKING TOWER, AUXILIARY INTERLOCKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. ENVIRONMENT, FROM SOUTHEAST, SHOWING B&P INTERLOCKING TOWER, AUXILIARY INTERLOCKING BUILDING, AND POWER SUBSTATION - Baltimore & Potomac Interlocking Tower, Adjacent to AMTRAK railroad tracks in block bounded by Howard Street, Jones Falls Expressway, Maryland Avenue & Falls Road, Baltimore, Independent City, MD

  4. 30 CFR 77.1103 - Flammable liquids; storage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... storage tanks shall be mounted securely on firm foundations. Outlet piping shall be provided with flexible connections or other special fittings to prevent adverse effects from tank settling. (c) Fuel lines shall be... hazards. (d) Areas surrounding flammable-liquid storage tanks and electric substations and transformers...

  5. 50. Photocopy of photograph, April 27, 1937. VIEW OF POWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. Photocopy of photograph, April 27, 1937. VIEW OF POWER HOUSE AND SUBSTATION DURING FLOOD. (Courtesy of the Potomac Edison Company Library (Hagerstown, MD), Historical Data Files, Dam No. 5 listing) - Dam No. 5 Hydroelectric Plant, On Potomac River, Hedgesville, Berkeley County, WV

  6. State and Substate Estimates of Nonmedical Use of Prescription Pain Relievers

    MedlinePlus

    ... of NSDUH's strengths is the stability of its survey design, which allows for multiple years of data to ... 204,000 respondents aged 12 or older. The Survey collects data by administering ... in Research Triangle Park, North Carolina. (RTI International is a ...

  7. 76 FR 53445 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... installed in a matrix on the bottom of the river; (2) the total capacity of the installation would be up to 75,000 kilowatts; (3) shielded underwater cables would convey each matrix power to a substation; and...

  8. 76 FR 53439 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... consist of: (1) Up to 75 TREK generating units installed in a matrix on the bottom of the river; (2) the... convey each matrix power to a substation; and (4) a transmission line would interconnect with the power...

  9. 76 FR 53446 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... installed in a matrix on the bottom of the river; (2) the total capacity of the installation would be up to 35,000 kilowatts; (3) shielded underwater cables would convey each matrix power to a substation; and...

  10. 76 FR 53444 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... following: (1) Up to 240 TREK generating units installed in a matrix on the bottom of the river; (2) the... convey each matrix power to a substation; and (4) a transmission line would interconnect with the power...

  11. 76 FR 53432 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...: (1) Up to 1,053 TREK generating units installed in a matrix on the bottom of the river; (2) the total... each matrix power to a substation; and (4) a transmission line would interconnect with the power grid...

  12. 76 FR 53429 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... consist of: (1) Up to 677 TREK generating units installed in a matrix on the bottom of the river; (2) the... would convey each matrix power to a substation; and (4) a transmission line would interconnect with the...

  13. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lines. When it is necessary to deenergize equipment or lines for protection of employees, the... performed by designated employees. (2) Precaution shall be taken to prevent accidental operation of relays... removed for construction purposes, a temporary fence affording similar protection when the site is...

  14. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... lines. When it is necessary to deenergize equipment or lines for protection of employees, the... performed by designated employees. (2) Precaution shall be taken to prevent accidental operation of relays... removed for construction purposes, a temporary fence affording similar protection when the site is...

  15. Oil leakage detection for electric power equipment based on ultraviolet fluorescence effect

    NASA Astrophysics Data System (ADS)

    Zhang, Jing; Wang, Jian-hui; Xu, Bin; Huang, Zhi-dong; Huang, Lan-tao

    2018-03-01

    This paper presents a method to detect the oil leakage of high voltage power equipment based on ultraviolet fluorescence effect. The method exploits the principle that the insulating oil has the fluorescent effect under the irradiation of specific ultraviolet light. The emission spectrum of insulating oil under excitation light with different wavelengths is measured and analyzed first. On this basis, a portable oil leakage detective device for high voltage power equipment is designed and developed with a selected 365 nm ultraviolet as the excitation light and the low light level camera as the fluorescence image collector. Then, the feasibility of the proposed method and device in different conditions is experimentally verified in the laboratory environment. Finally, the developed oil leakage detective device is applied to 500 kV Xiamen substation and Quanzhou substation. And the results show that the device can detect the oil leakage of high voltage electrical equipment quickly and conveniently even under the condition of a slight oil leakage especially in the low light environment.

  16. Collaborative Defense of Transmission and Distribution Protection and Control Devices Against Cyber Attacks (CODEF) DE-OE0000674. ABB Inc. Final Scientific/Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuqui, Reynaldo

    This report summarizes the activities conducted under the DOE-OE funded project DEOE0000674, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), and Ameren-Illinois (Ameren-IL) pursued the development of a system of collaborative defense of electrical substation’s intelligent electronic devices against cyber-attacks (CODEF). An electrical substation with CODEF features will be more capable of mitigating cyber-attacks especially those that seek to control switching devices. It leverages the security extensions of IEC 61850 to empower existing devices to collaborate in identifying and blocking malicious intents to trip circuit breakers, mis-coordinate devices settings, even thoughmore » the commands and the measurements comply with correct syntax. The CODEF functions utilize the physics of electromagnetic systems, electric power engineering principles, and computer science to bring more in depth cyber defense closer to the protected substation devices.« less

  17. Phosphorylation of an intrinsically disordered segment in Ets1 shifts conformational sampling toward binding-competent substates.

    PubMed

    Bui, Jennifer M; Gsponer, Jörg

    2014-08-05

    Functions of many proteins are affected by posttranslational modifications of intrinsically disordered (ID) regions, yet little is known about the underlying molecular mechanisms. By combining molecular dynamics simulations and protein docking, we demonstrate that the addition of phosphates to an ID segment adjacent to the PNT domain of Ets1 directs conformational sampling toward substates that are most compatible with high-affinity binding of the TAZ1 domain of its coactivator CBP. The phosphate charges disrupt salt bridges and thereby open a hydrophobic cleft and expose hydrophobic residues at the ID N terminus. The structure of the PNT-TAZ1 complex that we determined shows that PNT binds to TAZ1 via these hydrophobic regions in a similar manner to how it interacts with other partners. Our calculations reveal a dual effect of phosphorylation in that it changes the dynamics of PNT so that it becomes more compatible for TAZ1 binding and increases complementarity with this binding partner. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, Tommy Robert; Romero, Philbert Roland; Garcia, Samuel Anthony

    During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus maymore » increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.« less

  19. Hypothesized diprotomeric enzyme complex supported by stochastic modelling of palytoxin-induced Na/K pump channels

    PubMed Central

    Vilallonga, Gabriel D.; de Almeida, Antônio-Carlos G.; Ribeiro, Kelison T.; Campos, Sergio V. A.

    2018-01-01

    The sodium–potassium pump (Na+/K+ pump) is crucial for cell physiology. Despite great advances in the understanding of this ionic pumping system, its mechanism is not completely understood. We propose the use of a statistical model checker to investigate palytoxin (PTX)-induced Na+/K+ pump channels. We modelled a system of reactions representing transitions between the conformational substates of the channel with parameters, concentrations of the substates and reaction rates extracted from simulations reported in the literature, based on electrophysiological recordings in a whole-cell configuration. The model was implemented using the UPPAAL-SMC platform. Comparing simulations and probabilistic queries from stochastic system semantics with experimental data, it was possible to propose additional reactions to reproduce the single-channel dynamic. The probabilistic analyses and simulations suggest that the PTX-induced Na+/K+ pump channel functions as a diprotomeric complex in which protein–protein interactions increase the affinity of the Na+/K+ pump for PTX. PMID:29657808

  20. Study on Earthquake Response of High Voltage Electrical Equipment Coupling System with Flexible Busbar

    NASA Astrophysics Data System (ADS)

    Liu, Chuncheng; Qu, Da; Wang, Chongyang; Lv, Chunlei; Li, Guoqiang

    2017-12-01

    With the rapid development of technology and society, all walks of life in China are becoming more and more dependent on power systems. When earthquake occurs, the electrical equipment of substation is prone to damage because of its own structural features, top-heavy, and brittleness of main body. At the same time, due to the complex coupling of the soft electrical connection of substation electrical equipment, the negative impact can not be estimated. In this paper, the finite element model of the coupling system of the single unit of high voltage electrical equipment with the connecting soft bus is established and the seismic response is analysed. The results showed that there is a significant difference between the simple analysis for the seismic response of electrical equipment monomer and the analytical results of electrical equipment systems, and the impact on different electrical equipment is different. It lays a foundation for the future development of seismic performance analysis of extra high voltage electrical equipment.

  1. Structure-Function Perturbation and Dissociation of Tetrameric Urate Oxidase by High Hydrostatic Pressure

    PubMed Central

    Girard, Eric; Marchal, Stéphane; Perez, Javier; Finet, Stéphanie; Kahn, Richard; Fourme, Roger; Marassio, Guillaume; Dhaussy, Anne-Claire; Prangé, Thierry; Giffard, Marion; Dulin, Fabienne; Bonneté, Françoise; Lange, Reinhard; Abraini, Jacques H.; Mezouar, Mohamed; Colloc'h, Nathalie

    2010-01-01

    Abstract Structure-function relationships in the tetrameric enzyme urate oxidase were investigated using pressure perturbation. As the active sites are located at the interfaces between monomers, enzyme activity is directly related to the integrity of the tetramer. The effect of hydrostatic pressure on the enzyme was investigated by x-ray crystallography, small-angle x-ray scattering, and fluorescence spectroscopy. Enzymatic activity was also measured under pressure and after decompression. A global model, consistent with all measurements, discloses structural and functional details of the pressure-induced dissociation of the tetramer. Before dissociating, the pressurized protein adopts a conformational substate characterized by an expansion of its substrate binding pocket at the expense of a large neighboring hydrophobic cavity. This substate should be adopted by the enzyme during its catalytic mechanism, where the active site has to accommodate larger intermediates and product. The approach, combining several high-pressure techniques, offers a new (to our knowledge) means of exploring structural and functional properties of transient states relevant to protein mechanisms. PMID:20483346

  2. Multipole mixing ratios and substate populations in Rn-219

    NASA Astrophysics Data System (ADS)

    Jones, G. D.

    2016-08-01

    Historical alpha-gamma angular correlation data for the decay of 223Ra into excited states of 219Rn have been analysed, using the correct spins of the states involved, for the first time. The analyses produced multipole mixing ratios (E2/M1) of δ (144)=-0.11\\+/- 0.03, δ (154)=0, δ (158)=-0.205\\+/- 0.018 and δ (269)=-0.149\\+/- 0.004 where the nominal transition energies, in keV, are given in brackets. These values are consistent with published values obtained from internal conversion electron spectroscopy. It is also found that δ (324)=0 and δ (338)=-0.235\\+/- 0.030 (where both values differ from current tabulations) and that the sign of the multipole mixing ratio for the 122 keV transition is negative. The 158, 269 and 338 keV states are found to be aligned with high population of M=+/- 3/2 substates and the 127 keV state is believed to have undergone spin relaxation.

  3. A New Approach to Detection of Systematic Errors in Secondary Substation Monitoring Equipment Based on Short Term Load Forecasting

    PubMed Central

    Moriano, Javier; Rodríguez, Francisco Javier; Martín, Pedro; Jiménez, Jose Antonio; Vuksanovic, Branislav

    2016-01-01

    In recent years, Secondary Substations (SSs) are being provided with equipment that allows their full management. This is particularly useful not only for monitoring and planning purposes but also for detecting erroneous measurements, which could negatively affect the performance of the SS. On the other hand, load forecasting is extremely important since they help electricity companies to make crucial decisions regarding purchasing and generating electric power, load switching, and infrastructure development. In this regard, Short Term Load Forecasting (STLF) allows the electric power load to be predicted over an interval ranging from one hour to one week. However, important issues concerning error detection by employing STLF has not been specifically addressed until now. This paper proposes a novel STLF-based approach to the detection of gain and offset errors introduced by the measurement equipment. The implemented system has been tested against real power load data provided by electricity suppliers. Different gain and offset error levels are successfully detected. PMID:26771613

  4. Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in High-Voltage Equipment

    NASA Astrophysics Data System (ADS)

    Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.

    2018-03-01

    Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.

  5. Characterization of biomass waste torrefaction under conventional and microwave heating.

    PubMed

    Ho, Shih-Hsin; Zhang, Congyu; Chen, Wei-Hsin; Shen, Ying; Chang, Jo-Shu

    2018-05-13

    To evaluate the potential of microwave heating for biomass torrefaction, the torrefaction performances and energy utilization of coffee grounds and microalga residue, under conventional and microwave heating were investigated and compared with each other. For the two biomass samples, the dehydrogenation of the coffee grounds was more sensitive to torrefaction severity, whereas the microalga residue consumed more energy under the same torrefaction conditions. Microwave heating under lower torrefaction severity had a higher energy efficiency. As regard to the lower solid yields or higher torrefaction severity, the energy efficiency of microwave heating was close to that of conventional heating, irrespective of the feedstocks. This revealed the comparable energy consumption state between the two heating modes. Accordingly, it is concluded that microwave torrefaction is more efficient for biomass upgrading and densification than conventional torrefaction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Heat exchanger selection and design analyses for metal hydride heat pump systems

    DOE PAGES

    Mazzucco, Andrea; Voskuilen, Tyler G.; Waters, Essene L.; ...

    2016-01-01

    This paper presents a design analysis for the development of highly efficient heat exchangers within stationary metal hydride heat pumps. The design constraints and selected performance criteria are applied to three representative heat exchangers. The proposed thermal model can be applied to select the most efficient heat exchanger design and provides outcomes generally valid in a pre-design stage. Heat transfer effectiveness is the principal performance parameter guiding the selection analysis, the results of which appear to be mildly (up to 13%) affected by the specific Nusselt correlation used. The thermo-physical properties of the heat transfer medium and geometrical parameters aremore » varied in the sensitivity analysis, suggesting that the length of independent tubes is the physical parameter that influences the performance of the heat exchangers the most. The practical operative regions for each heat exchanger are identified by finding the conditions over which the heat removal from the solid bed enables a complete and continuous hydriding reaction. The most efficient solution is a design example that achieves the target effectiveness of 95%.« less

  7. Thermoelectric Power Generation System for Future Hybrid Vehicles Using Hot Exhaust Gas

    NASA Astrophysics Data System (ADS)

    Kim, Sun-Kook; Won, Byeong-Cheol; Rhi, Seok-Ho; Kim, Shi-Ho; Yoo, Jeong-Ho; Jang, Ju-Chan

    2011-05-01

    The present experimental and computational study investigates a new exhaust gas waste heat recovery system for hybrid vehicles, using a thermoelectric module (TEM) and heat pipes to produce electric power. It proposes a new thermoelectric generation (TEG) system, working with heat pipes to produce electricity from a limited hot surface area. The current TEG system is directly connected to the exhaust pipe, and the amount of electricity generated by the TEMs is directly proportional to their heated area. Current exhaust pipes fail to offer a sufficiently large hot surface area for the high-efficiency waste heat recovery required. To overcome this, a new TEG system has been designed to have an enlarged hot surface area by the addition of ten heat pipes, which act as highly efficient heat transfer devices and can transmit the heat to many TEMs. As designed, this new waste heat recovery system produces a maximum 350 W when the hot exhaust gas heats the evaporator surface of the heat pipe to 170°C; this promises great possibilities for application of this technology in future energy-efficient hybrid vehicles.

  8. 3D Power Line Extraction from Multiple Aerial Images.

    PubMed

    Oh, Jaehong; Lee, Changno

    2017-09-29

    Power lines are cables that carry electrical power from a power plant to an electrical substation. They must be connected between the tower structures in such a way that ensures minimum tension and sufficient clearance from the ground. Power lines can stretch and sag with the changing weather, eventually exceeding the planned tolerances. The excessive sags can then cause serious accidents, while hindering the durability of the power lines. We used photogrammetric techniques with a low-cost drone to achieve efficient 3D mapping of power lines that are often difficult to approach. Unlike the conventional image-to-object space approach, we used the object-to-image space approach using cubic grid points. We processed four strips of aerial images to automatically extract the power line points in the object space. Experimental results showed that the approach could successfully extract the positions of the power line points for power line generation and sag measurement with the elevation accuracy of a few centimeters.

  9. 3D Power Line Extraction from Multiple Aerial Images

    PubMed Central

    Lee, Changno

    2017-01-01

    Power lines are cables that carry electrical power from a power plant to an electrical substation. They must be connected between the tower structures in such a way that ensures minimum tension and sufficient clearance from the ground. Power lines can stretch and sag with the changing weather, eventually exceeding the planned tolerances. The excessive sags can then cause serious accidents, while hindering the durability of the power lines. We used photogrammetric techniques with a low-cost drone to achieve efficient 3D mapping of power lines that are often difficult to approach. Unlike the conventional image-to-object space approach, we used the object-to-image space approach using cubic grid points. We processed four strips of aerial images to automatically extract the power line points in the object space. Experimental results showed that the approach could successfully extract the positions of the power line points for power line generation and sag measurement with the elevation accuracy of a few centimeters. PMID:28961204

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Happenny, Sean F.

    The United States’ power infrastructure is aging, underfunded, and vulnerable to cyber attack. Emerging smart grid technologies may take some of the burden off of existing systems and make the grid as a whole more efficient, reliable, and secure. The Pacific Northwest National Laboratory (PNNL) is funding research into several aspects of smart grid technology and grid security, creating a software simulation tool that will allow researchers to test power distribution networks utilizing different smart grid technologies to determine how the grid and these technologies react under different circumstances. Demonstrating security in embedded systems is another research area PNNL ismore » tackling. Many of the systems controlling the U.S. critical infrastructure, such as the power grid, lack integrated security and the networks protecting them are becoming easier to breach. Providing a virtual power substation network to each student team at the National Collegiate Cyber Defense Competition, thereby supporting the education of future cyber security professionals, is another way PNNL is helping to strengthen the security of the nation’s power infrastructure.« less

  11. Free Energy Calculations using a Swarm-Enhanced Sampling Molecular Dynamics Approach.

    PubMed

    Burusco, Kepa K; Bruce, Neil J; Alibay, Irfan; Bryce, Richard A

    2015-10-26

    Free energy simulations are an established computational tool in modelling chemical change in the condensed phase. However, sampling of kinetically distinct substates remains a challenge to these approaches. As a route to addressing this, we link the methods of thermodynamic integration (TI) and swarm-enhanced sampling molecular dynamics (sesMD), where simulation replicas interact cooperatively to aid transitions over energy barriers. We illustrate the approach by using alchemical alkane transformations in solution, comparing them with the multiple independent trajectory TI (IT-TI) method. Free energy changes for transitions computed by using IT-TI grew increasingly inaccurate as the intramolecular barrier was heightened. By contrast, swarm-enhanced sampling TI (sesTI) calculations showed clear improvements in sampling efficiency, leading to more accurate computed free energy differences, even in the case of the highest barrier height. The sesTI approach, therefore, has potential in addressing chemical change in systems where conformations exist in slow exchange. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Irreversible Brownian Heat Engine

    NASA Astrophysics Data System (ADS)

    Taye, Mesfin Asfaw

    2017-10-01

    We model a Brownian heat engine as a Brownian particle that hops in a periodic ratchet potential where the ratchet potential is coupled with a linearly decreasing background temperature. We show that the efficiency of such Brownian heat engine approaches the efficiency of endoreversible engine η =1-√{{Tc/Th}} [23]. On the other hand, the maximum power efficiency of the engine approaches η ^{MAX}=1-({Tc/Th})^{1\\over 4}. It is shown that the optimized efficiency always lies between the efficiency at quasistatic limit and the efficiency at maximum power while the efficiency at maximum power is always less than the optimized efficiency since the fast motion of the particle comes at the expense of the energy cost. If the heat exchange at the boundary of the heat baths is included, we show that such a Brownian heat engine has a higher performance when acting as a refrigerator than when operating as a device subjected to a piecewise constant temperature. The role of time on the performance of the motor is also explored via numerical simulations. Our numerical results depict that the time t and the external load dictate the direction of the particle velocity. Moreover, the performance of the heat engine improves with time. At large t (steady state), the velocity, the efficiency and the coefficient of performance of the refrigerator attain their maximum value. Furthermore, we study the effect of temperature by considering a viscous friction that decreases exponentially as the background temperature increases. Our result depicts that the Brownian particle exhibits a fast unidirectional motion when the viscous friction is temperature dependent than that of constant viscous friction. Moreover, the efficiency of this motor is considerably enhanced when the viscous friction is temperature dependent. On the hand, the motor exhibits a higher performance of the refrigerator when the viscous friction is taken to be constant.

  13. Thermally enhanced photoluminescence for heat harvesting in photovoltaics

    PubMed Central

    Manor, Assaf; Kruger, Nimrod; Sabapathy, Tamilarasan; Rotschild, Carmel

    2016-01-01

    The maximal Shockley–Queisser efficiency limit of 41% for single-junction photovoltaics is primarily caused by heat dissipation following energetic-photon absorption. Solar-thermophotovoltaics concepts attempt to harvest this heat loss, but the required high temperatures (T>2,000 K) hinder device realization. Conversely, we have recently demonstrated how thermally enhanced photoluminescence is an efficient optical heat-pump that operates in comparably low temperatures. Here we theoretically and experimentally demonstrate such a thermally enhanced photoluminescence based solar-energy converter. Here heat is harvested by a low bandgap photoluminescent absorber that emits thermally enhanced photoluminescence towards a higher bandgap photovoltaic cell, resulting in a maximum theoretical efficiency of 70% at a temperature of 1,140 K. We experimentally demonstrate the key feature of sub-bandgap photon thermal upconversion with an efficiency of 1.4% at only 600 K. Experiments on white light excitation of a tailored Cr:Nd:Yb glass absorber suggest that conversion efficiencies as high as 48% at 1,500 K are in reach. PMID:27762271

  14. Comparison of three systems of solar water heating by thermosiphon

    NASA Astrophysics Data System (ADS)

    Hernández, E.; Guzmán, R. E.

    2016-02-01

    The main purpose of this project was to elaborate a comparison between three water heating systems; using two plane water heating solar collector and another using a vacuum tube heater, all of them are on top of the cafeteria's roof on building of the “Universidad Pontificia Bolivariana” in Bucaramanga, Colombia. Through testing was determined each type of water heating systems' performance, where the Stainless Steel tube collector reached a maximum efficiency of 71.58%, the Copper Tubing Collector a maximum value of 76.31% and for the Vacuum Tube Heater Collector a maximum efficiency of 72.33%. The collector with copper coil was the system more efficient. So, taking into account the Performance and Temperature Curves, along with the weather conditions at the time of the testing we determined that the most efficient Solar Heating System is the one using a Vacuum Tube Heater Collector. Reaching a maximum efficiency of 72.33% and a maximum temperature of 62.6°C.

  15. High Temperature Concentrated Solar Power Using Liquid Metal

    NASA Astrophysics Data System (ADS)

    Henry, Asegun

    One of the most attractive ways to try and reduce the cost of concentrated solar power (CSP) is to increase the system efficiency and the biggest loss in the system occurs in the conversion of heat to electricity via heat engine. Heat engines that utilize turbomachinery currently operate near their thermodynamic limitations and thus one of the only ways to improve heat engine efficiency is to increase the turbine inlet temperature. Significant effort is being devoted to the development of supercritical CO2 heat engines, but the most efficient heat engines are combined cycles, which reach efficiencies as high as 60%. However, such heat engines require turbine inlet temperatures ~1300-1500C, which is far beyond what is currently feasible with the state of the art molten salt infrastructure. In working towards the development of a system that can operate in the 1300-1500C temperature range, the most significant challenges lie in the materials and forming functional and reliable components out of new materials. One of the most attractive options from a cost and heat transfer perspective is to use liquid metals, such as tin and aluminum-silicon alloys along with a ceramic based infrastructure. This talk will overview ongoing efforts in the Atomistic Simulation and Energy (ASE) research group at Georgia Tech to develop prototype components such as an efficient high temperature cavity receiver, pumps and valves that can make a liquid metal based CSP infrastructure realizable.

  16. Heat rejection efficiency research of new energy automobile radiators

    NASA Astrophysics Data System (ADS)

    Ma, W. S.; Shen, W. X.; Zhang, L. W.

    2018-03-01

    The driving system of new energy vehicle has larger heat load than conventional engine. How to ensure the heat dissipation performance of the cooling system is the focus of the design of new energy vehicle thermal management system. In this paper, the heat dissipation efficiency of the radiator of the hybrid electric vehicle is taken as the research object, the heat dissipation efficiency of the radiator of the new energy vehicle is studied through the multi-working-condition enthalpy difference test. In this paper, the test method in the current standard QC/T 468-2010 “automobile radiator” is taken, but not limited to the test conditions specified in the standard, 5 types of automobile radiator are chosen, each of them is tested 20 times in simulated condition of different wind speed and engine inlet temperature. Finally, regression analysis is carried out for the test results, and regression equation describing the relationship of radiator heat dissipation heat dissipation efficiency air side flow rate cooling medium velocity and inlet air temperature is obtained, and the influence rule is systematically discussed.

  17. What Is the Real Efficiency of Bulbs?

    ERIC Educational Resources Information Center

    Polacek, Lubos

    2012-01-01

    Bulbs are considered to be very inefficient sources of light. Bulbs give light and heat. As we use them for a long time, especially in winter, a large part of the heat produced by bulbs lowers the power consumption of the heating system. In this paper the problem of the real efficiency of a bulb is solved when both the lighting and heating effects…

  18. Achieving the classical Carnot efficiency in a strongly coupled quantum heat engine

    NASA Astrophysics Data System (ADS)

    Xu, Y. Y.; Chen, B.; Liu, J.

    2018-02-01

    Generally, the efficiency of a heat engine strongly coupled with a heat bath is less than the classical Carnot efficiency. Through a model-independent method, we show that the classical Carnot efficiency is achieved in a strongly coupled quantum heat engine. First, we present the first law of quantum thermodynamics in strong coupling. Then, we show how to achieve the Carnot cycle and the classical Carnot efficiency at strong coupling. We find that this classical Carnot efficiency stems from the fact that the heat released in a nonequilibrium process is balanced by the absorbed heat. We also analyze the restrictions in the achievement of the Carnot cycle. The first restriction is that there must be two corresponding intervals of the controllable parameter in which the corresponding entropies of the work substance at the hot and cold temperatures are equal, and the second is that the entropy of the initial and final states in a nonequilibrium process must be equal. Through these restrictions, we obtain the positive work conditions, including the usual one in which the hot temperature should be higher than the cold, and a new one in which there must be an entropy interval at the hot temperature overlapping that at the cold. We demonstrate our result through a paradigmatic model—a two-level system in which a work substance strongly interacts with a heat bath. In this model, we find that the efficiency may abruptly decrease to zero due to the first restriction, and that the second restriction results in the control scheme becoming complex.

  19. Achieving the classical Carnot efficiency in a strongly coupled quantum heat engine.

    PubMed

    Xu, Y Y; Chen, B; Liu, J

    2018-02-01

    Generally, the efficiency of a heat engine strongly coupled with a heat bath is less than the classical Carnot efficiency. Through a model-independent method, we show that the classical Carnot efficiency is achieved in a strongly coupled quantum heat engine. First, we present the first law of quantum thermodynamics in strong coupling. Then, we show how to achieve the Carnot cycle and the classical Carnot efficiency at strong coupling. We find that this classical Carnot efficiency stems from the fact that the heat released in a nonequilibrium process is balanced by the absorbed heat. We also analyze the restrictions in the achievement of the Carnot cycle. The first restriction is that there must be two corresponding intervals of the controllable parameter in which the corresponding entropies of the work substance at the hot and cold temperatures are equal, and the second is that the entropy of the initial and final states in a nonequilibrium process must be equal. Through these restrictions, we obtain the positive work conditions, including the usual one in which the hot temperature should be higher than the cold, and a new one in which there must be an entropy interval at the hot temperature overlapping that at the cold. We demonstrate our result through a paradigmatic model-a two-level system in which a work substance strongly interacts with a heat bath. In this model, we find that the efficiency may abruptly decrease to zero due to the first restriction, and that the second restriction results in the control scheme becoming complex.

  20. Exergy analysis of large-scale helium liquefiers: Evaluating design trade-offs

    NASA Astrophysics Data System (ADS)

    Thomas, Rijo Jacob; Ghosh, Parthasarathi; Chowdhury, Kanchan

    2014-01-01

    It is known that higher heat exchanger area, more number of expanders with higher efficiency and more involved configuration with multi-pressure compression system increase the plant efficiency of a helium liquefier. However, they involve higher capital investment and larger size. Using simulation software Aspen Hysys v 7.0 and exergy analysis as the tool of analysis, authors have attempted to identify various trade-offs while selecting the number of stages, the pressure levels in compressor, the cold-end configuration, the heat exchanger surface area, the maximum allowable pressure drop in heat exchangers, the efficiency of expanders, the parallel/series connection of expanders etc. Use of more efficient cold ends reduces the number of refrigeration stages and the size of the plant. For achieving reliability along with performance, a configuration with a combination of expander and Joule-Thomson valve is found to be a better choice for cold end. Use of multi-pressure system is relevant only when the number of refrigeration stages is more than 5. Arrangement of expanders in series reduces the number of expanders as well as the heat exchanger size with slight expense of plant efficiency. Superior heat exchanger (having less pressure drop per unit heat transfer area) results in only 5% increase of plant performance even when it has 100% higher heat exchanger surface area.

  1. 75 FR 21777 - Regulatory Agenda

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-26

    ... flexibility analyses: Energy Efficiency Standards for Pool Heaters and Direct Heating Equipment and Water... Heaters and Direct Heating Equipment and Water 1904-AA90 Heaters 119 Test Procedures for Walk-In Coolers... Renewable Energy (EE) 118. ENERGY EFFICIENCY STANDARDS FOR POOL HEATERS AND DIRECT HEATING EQUIPMENT AND...

  2. Department of Energy Semiannual Regulatory Agenda

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-26

    ...: Energy Efficiency Standards for Pool Heaters and Direct Heating Equipment and Water Heaters, and Test... EFFICIENCY STANDARDS FOR POOL HEATERS AND DIRECT HEATING EQUIPMENT AND WATER HEATERS Legal Authority: 42 USC... and direct heating equipment. This is the second review for water heaters. Timetable: Action Date FR...

  3. Mitochondrial efficiency and exercise economy following heat stress: a potential role of uncoupling protein 3.

    PubMed

    Salgado, Roy M; Sheard, Ailish C; Vaughan, Roger A; Parker, Daryl L; Schneider, Suzanne M; Kenefick, Robert W; McCormick, James J; Gannon, Nicholas P; Van Dusseldorp, Trisha A; Kravitz, Len R; Mermier, Christine M

    2017-02-01

    Heat stress has been reported to reduce uncoupling proteins (UCP) expression, which in turn should improve mitochondrial efficiency. Such an improvement in efficiency may translate to the systemic level as greater exercise economy. However, neither the heat-induced improvement in mitochondrial efficiency (due to decrease in UCP), nor its potential to improve economy has been studied. Determine: (i) if heat stress in vitro lowers UCP3 thereby improving mitochondrial efficiency in C2C12 myocytes; (ii) whether heat acclimation (HA) in vivo improves exercise economy in trained individuals; and (iii) the potential improved economy during exercise at altitude. In vitro, myocytes were heat stressed for 24 h (40°C), followed by measurements of UCP3, mitochondrial uncoupling, and efficiency. In vivo, eight trained males completed: (i) pre-HA testing; (ii) 10 days of HA (40°C, 20% RH); and (iii) post-HA testing. Pre- and posttesting consisted of maximal exercise test and submaximal exercise at two intensities to assess exercise economy at 1600 m (Albuquerque, NM) and 4350 m. Heat-stressed myocytes displayed significantly reduced UCP3 mRNA expression and, mitochondrial uncoupling (77.1 ± 1.2%, P < 0.0001) and improved mitochondrial efficiency (62.9 ± 4.1%, P < 0.0001) compared to control. In humans, at both 1600 m and 4350 m, following HA, submaximal exercise economy did not change at low and moderate exercise intensities. Our findings indicate that while heat-induced reduction in UCP3 improves mitochondrial efficiency in vitro, this is not translated to in vivo improvement of exercise economy at 1600 m or 4350 m. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  4. Efficiency of Brownian heat engines.

    PubMed

    Derényi, I; Astumian, R D

    1999-06-01

    We study the efficiency of one-dimensional thermally driven Brownian ratchets or heat engines. We identify and compare the three basic setups characterized by the type of the connection between the Brownian particle and the two heat reservoirs: (i) simultaneous, (ii) alternating in time, and (iii) position dependent. We make a clear distinction between the heat flow via the kinetic and the potential energy of the particle, and show that the former is always irreversible and it is only the third setup where the latter is reversible when the engine works quasistatically. We also show that in the third setup the heat flow via the kinetic energy can be reduced arbitrarily, proving that even for microscopic heat engines there is no fundamental limit of the efficiency lower than that of a Carnot cycle.

  5. 40 CFR 256.65 - Recommendations for public participation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Recommendations for public... Participation § 256.65 Recommendations for public participation. (a) State and substate planning agencies should establish an advisory group, or utilize an existing group, to provide recommendations on major policy and...

  6. 75 FR 27550 - Electrical Interconnection of the Juniper Canyon I Wind Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-17

    ... Canyon I Wind Project AGENCY: Bonneville Power Administration (BPA), Department of Energy (DOE). ACTION: Notice of Availability of Record of Decision (ROD). SUMMARY: The Bonneville Power Administration (BPA... County, Washington. To interconnect the Wind Project, BPA will expand an existing substation (Rock Creek...

  7. 76 FR 63294 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-12

    ... that the Commission received the following electric rate filings: Docket Numbers: ER11-3812-001... Time on Monday, October 24, 2011. Docket Numbers: ER12-11-000. Applicants: Nevada Power Company. Description: Nevada Power Company submits tariff filing per 35.12: Rate Schedule No. 123 Merchant Substation...

  8. 75 FR 7231 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-18

    ... Business Service (RBS) through Rural Development State and sub-State offices serving each State. Need and Use of the Information: RBS will collect information to determine a lender and borrower eligibility and creditworthiness. The information is used by RBS loan officers and approval officials to determine...

  9. 77 FR 14416 - Notice of Availability of a Final Environmental Impact Statement and Final Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... wind turbine generators; a substation; administration, operations and maintenance facilities... Action (the ``Refined Project''). Under the Refined Project configuration, only 112 wind turbines... Report for the Pattern Energy Group's Ocotillo Express Wind Energy Project and Proposed California Desert...

  10. 76 FR 53449 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...) Up to 320 TREK generating units installed in a matrix on the bottom of the river; (2) the total... each matrix's power to a substation; and (4) a transmission line would interconnect with the power grid. The proposed [[Page 53450

  11. Patterns of State-Regional Cooperation in Nebraska.

    ERIC Educational Resources Information Center

    Bansal, Prem Lata

    This study empirically explores patterns of authority delegation by Nebraska state agencies to substate regional organizations and evaluates the effectiveness of those patterns in realizing the goals of decentralization. Information about the field operations and role perceptions of various state agencies was gathered through use of a…

  12. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-81)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-07-09

    BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within The Dalles District of the Redmond Region.

  13. Development of an engineering model traveling wave tube amplifier for space communication systems

    NASA Technical Reports Server (NTRS)

    Eallonardo, C. M.; Songli, J.; Basiulis, A.

    1972-01-01

    A design has been made of a 100 watt traveling-wave tube amplifier for use in space communication applications. The features of very high overall efficiency and heat rejection of waste heat at low thermal densities were predominant in the design concept. The design concept was proven by building a series of tubes, operating at efficiencies up to 50%. These tubes utilized heat pipe cooling and heat distribution such that 150 watts of waste heat was rejected at a density of less than 1.5 watts per square inch. A power supply to convert a 28 volt primary line of the needs of the TWT was built and operated at 85% efficiency.

  14. Efficiently-cooled plasmonic amorphous silicon solar cells integrated with a nano-coated heat-pipe plate

    PubMed Central

    Zhang, Yinan; Du, Yanping; Shum, Clifford; Cai, Boyuan; Le, Nam Cao Hoai; Chen, Xi; Duck, Benjamin; Fell, Christopher; Zhu, Yonggang; Gu, Min

    2016-01-01

    Solar photovoltaics (PV) are emerging as a major alternative energy source. The cost of PV electricity depends on the efficiency of conversion of light to electricity. Despite of steady growth in the efficiency for several decades, little has been achieved to reduce the impact of real-world operating temperatures on this efficiency. Here we demonstrate a highly efficient cooling solution to the recently emerging high performance plasmonic solar cell technology by integrating an advanced nano-coated heat-pipe plate. This thermal cooling technology, efficient for both summer and winter time, demonstrates the heat transportation capability up to ten times higher than those of the metal plate and the conventional wickless heat-pipe plates. The reduction in temperature rise of the plasmonic solar cells operating under one sun condition can be as high as 46%, leading to an approximate 56% recovery in efficiency, which dramatically increases the energy yield of the plasmonic solar cells. This newly-developed, thermally-managed plasmonic solar cell device significantly extends the application scope of PV for highly efficient solar energy conversion. PMID:27113558

  15. Efficiently-cooled plasmonic amorphous silicon solar cells integrated with a nano-coated heat-pipe plate.

    PubMed

    Zhang, Yinan; Du, Yanping; Shum, Clifford; Cai, Boyuan; Le, Nam Cao Hoai; Chen, Xi; Duck, Benjamin; Fell, Christopher; Zhu, Yonggang; Gu, Min

    2016-04-26

    Solar photovoltaics (PV) are emerging as a major alternative energy source. The cost of PV electricity depends on the efficiency of conversion of light to electricity. Despite of steady growth in the efficiency for several decades, little has been achieved to reduce the impact of real-world operating temperatures on this efficiency. Here we demonstrate a highly efficient cooling solution to the recently emerging high performance plasmonic solar cell technology by integrating an advanced nano-coated heat-pipe plate. This thermal cooling technology, efficient for both summer and winter time, demonstrates the heat transportation capability up to ten times higher than those of the metal plate and the conventional wickless heat-pipe plates. The reduction in temperature rise of the plasmonic solar cells operating under one sun condition can be as high as 46%, leading to an approximate 56% recovery in efficiency, which dramatically increases the energy yield of the plasmonic solar cells. This newly-developed, thermally-managed plasmonic solar cell device significantly extends the application scope of PV for highly efficient solar energy conversion.

  16. Generation of a Parabolic Trough Collector Efficiency Curve from Separate Measurements of Outdoor Optical Efficiency and Indoor Receiver Heat Loss

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kutscher, C.; Burkholder, F.; Stynes, J. K.

    2012-02-01

    The thermal efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The thermal efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain the thermal efficiency curve. This paper describes this approach and also makes the case that there are advantagesmore » to plotting collector efficiency versus the difference between the operating temperature and the ambient temperature at which the receiver heat loss was measured divided by radiation to a fractional power (on the order of 1/3 but obtained via data regression) - as opposed to the difference between operating and ambient temperatures divided by the radiation. The results are shown to be robust over wide ranges of ambient temperature, sky temperature, and wind speed.« less

  17. Efficiently-cooled plasmonic amorphous silicon solar cells integrated with a nano-coated heat-pipe plate

    NASA Astrophysics Data System (ADS)

    Zhang, Yinan; Du, Yanping; Shum, Clifford; Cai, Boyuan; Le, Nam Cao Hoai; Chen, Xi; Duck, Benjamin; Fell, Christopher; Zhu, Yonggang; Gu, Min

    2016-04-01

    Solar photovoltaics (PV) are emerging as a major alternative energy source. The cost of PV electricity depends on the efficiency of conversion of light to electricity. Despite of steady growth in the efficiency for several decades, little has been achieved to reduce the impact of real-world operating temperatures on this efficiency. Here we demonstrate a highly efficient cooling solution to the recently emerging high performance plasmonic solar cell technology by integrating an advanced nano-coated heat-pipe plate. This thermal cooling technology, efficient for both summer and winter time, demonstrates the heat transportation capability up to ten times higher than those of the metal plate and the conventional wickless heat-pipe plates. The reduction in temperature rise of the plasmonic solar cells operating under one sun condition can be as high as 46%, leading to an approximate 56% recovery in efficiency, which dramatically increases the energy yield of the plasmonic solar cells. This newly-developed, thermally-managed plasmonic solar cell device significantly extends the application scope of PV for highly efficient solar energy conversion.

  18. European Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Vishaldeep; Shen, Bo; Keinath, Chris

    2017-01-01

    High efficiency gas-burning hot water heating takes advantage of a condensing heat exchanger to deliver improved combustion efficiency over a standard non-condensing configuration. The water heating is always lower than the gas heating value. In contrast, Gas Absorption Heat Pump (GAHP) hot water heating combines the efficiency of gas burning with the performance increase from a heat pump to offer significant gas energy savings. An ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. In comparison with air source electric heat pumps, the absorption system can maintain higher coefficients of performance in coldermore » climates. In this work, a GAHP commercial water heating system was compared to a condensing gas storage system for a range of locations and climate zones across Europe. The thermodynamic performance map of a single effect ammonia-water absorption system was used in a building energy modeling software that could also incorporate the changing ambient air temperature and water mains temperature for a specific location, as well as a full-service restaurant water draw pattern.« less

  19. Heat Management in Thermoelectric Power Generators

    PubMed Central

    Zebarjadi, M.

    2016-01-01

    Thermoelectric power generators are used to convert heat into electricity. Like any other heat engine, the performance of a thermoelectric generator increases as the temperature difference on the sides increases. It is generally assumed that as more heat is forced through the thermoelectric legs, their performance increases. Therefore, insulations are typically used to minimize the heat losses and to confine the heat transport through the thermoelectric legs. In this paper we show that to some extend it is beneficial to purposely open heat loss channels in order to establish a larger temperature gradient and therefore to increase the overall efficiency and achieve larger electric power output. We define a modified Biot number (Bi) as an indicator of requirements for sidewall insulation. We show cooling from sidewalls increases the efficiency for Bi values less than one, and decreases the efficiency for Bi values larger than one. PMID:27033717

  20. Heat pipe array heat exchanger

    DOEpatents

    Reimann, Robert C.

    1987-08-25

    A heat pipe arrangement for exchanging heat between two different temperature fluids. The heat pipe arrangement is in a ounterflow relationship to increase the efficiency of the coupling of the heat from a heat source to a heat sink.

  1. 10 CFR 430.62 - Submission of data.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... energy factor expressed in cycles per kilowatt-hour. (vii) Faucets, the maximum water use in gpm (L/min... seasonal energy efficiency ratio and heating seasonal performance factor. For central air conditioning heat pumps whose seasonal energy efficiency ratio and heating seasonal performance factor are based on an...

  2. Evaluation of Energy Efficient Options to Heat Ohio Department of Transportation (ODOT) Maintenance Facilities

    DOT National Transportation Integrated Search

    2018-01-01

    This project was initiated by the ODOT District 2 staff who were looking for more efficient ways to heat and operate their maintenance facilities. This especially applied to the idea of using radiant floor heating as an alternative to todays stand...

  3. Hybrid Pressure Retarded Osmosis-Membrane Distillation System for Power Generation from Low-Grade Heat: Thermodynamic Analysis and Energy Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, SH; Yip, NY; Cath, TY

    2014-05-06

    We present a novel hybrid membrane system that operates as a heat engine capable of utilizing low-grade thermal energy, which is not readily recoverable with existing technologies. The closed-loop system combines membrane distillation (MD), which generates concentrated and pure water streams by thermal separation, and pressure retarded osmosis (PRO), which converts the energy of mixing to electricity by a hydro-turbine. The PRO-MD system was modeled by coupling the mass and energy flows between the thermal separation (MD) and power generation (PRO) stages for heat source temperatures ranging from 40 to 80 degrees C and working concentrations of 1.0, 2.0, andmore » 4.0 mol/kg NaCl. The factors controlling the energy efficiency of the heat engine were evaluated for both limited and unlimited mass and heat transfer kinetics in the thermal separation stage. In both cases, the relative flow rate between the MD permeate (distillate) and feed streams is identified as an important operation parameter. There is an optimal relative flow rate that maximizes the overall energy efficiency of the PRO-MD system for given working temperatures and concentration. In the case of unlimited mass and heat transfer kinetics, the energy efficiency of the system can be analytically determined based on thermodynamics. Our assessment indicates that the hybrid PRO-MD system can theoretically achieve an energy efficiency of 9.8% (81.6% of the Carnot efficiency) with hot and cold working temperatures of 60 and 20 degrees C, respectively, and a working solution of 1.0 M NaCl. When mass and heat transfer kinetics are limited, conditions that more closely represent actual operations, the practical energy efficiency will be lower than the theoretically achievable efficiency. In such practical operations, utilizing a higher working concentration will yield greater energy efficiency. Overall, our study demonstrates the theoretical viability of the PRO-MD system and identifies the key factors for performance optimization.« less

  4. Hybrid pressure retarded osmosis-membrane distillation system for power generation from low-grade heat: thermodynamic analysis and energy efficiency.

    PubMed

    Lin, Shihong; Yip, Ngai Yin; Cath, Tzahi Y; Osuji, Chinedum O; Elimelech, Menachem

    2014-05-06

    We present a novel hybrid membrane system that operates as a heat engine capable of utilizing low-grade thermal energy, which is not readily recoverable with existing technologies. The closed-loop system combines membrane distillation (MD), which generates concentrated and pure water streams by thermal separation, and pressure retarded osmosis (PRO), which converts the energy of mixing to electricity by a hydro-turbine. The PRO-MD system was modeled by coupling the mass and energy flows between the thermal separation (MD) and power generation (PRO) stages for heat source temperatures ranging from 40 to 80 °C and working concentrations of 1.0, 2.0, and 4.0 mol/kg NaCl. The factors controlling the energy efficiency of the heat engine were evaluated for both limited and unlimited mass and heat transfer kinetics in the thermal separation stage. In both cases, the relative flow rate between the MD permeate (distillate) and feed streams is identified as an important operation parameter. There is an optimal relative flow rate that maximizes the overall energy efficiency of the PRO-MD system for given working temperatures and concentration. In the case of unlimited mass and heat transfer kinetics, the energy efficiency of the system can be analytically determined based on thermodynamics. Our assessment indicates that the hybrid PRO-MD system can theoretically achieve an energy efficiency of 9.8% (81.6% of the Carnot efficiency) with hot and cold working temperatures of 60 and 20 °C, respectively, and a working solution of 1.0 M NaCl. When mass and heat transfer kinetics are limited, conditions that more closely represent actual operations, the practical energy efficiency will be lower than the theoretically achievable efficiency. In such practical operations, utilizing a higher working concentration will yield greater energy efficiency. Overall, our study demonstrates the theoretical viability of the PRO-MD system and identifies the key factors for performance optimization.

  5. A new method of efficient heat transfer and storage at very high temperatures

    NASA Technical Reports Server (NTRS)

    Shaw, D.; Bruckner, A. P.; Hertzberg, A.

    1980-01-01

    A unique, high temperature (1000-2000 K) continuously operating capacitive heat exchanger system is described. The system transfers heat from a combustion or solar furnace to a working gas by means of a circulating high temperature molten refractory. A uniform aggregate of beads of a glass-like refractory is injected into the furnace volume. The aggregate is melted and piped to a heat exchanger where it is sprayed through a counter-flowing, high pressure working gas. The refractory droplets transfer their heat to the gas, undergoing a phase change into the solid bead state. The resulting high temperature gas is used to drive a suitable high efficiency heat engine. The solidified refractory beads are delivered back to the furnace and melted to continue the cycle. This approach avoids the important temperature limitations of conventional tube-type heat exchangers, giving rise to the potential of converting heat energy into useful work at considerably higher efficiencies than currently attainable and of storing energy at high thermodynamic potential.

  6. Demonstration of Efficient Core Heating of Magnetized Fast Ignition in FIREX project

    NASA Astrophysics Data System (ADS)

    Johzaki, Tomoyuki

    2017-10-01

    Extensive theoretical and experimental research in the FIREX ``I project over the past decade revealed that the large angular divergence of the laser generated electron beam is one of the most critical problems inhibiting efficient core heating in electron-driven fast ignition. To solve this problem, beam guiding using externally applied kilo-tesla class magnetic field was proposed, and its feasibility has recently been numerically demonstrated. In 2016, integrated experiments at ILE Osaka University demonstrated core heating efficiencies reaching > 5 % and heated core temperatures of 1.7 keV. In these experiments, a kilo-tesla class magnetic field was applied to a cone-attached Cu(II) oleate spherical solid target by using a laser-driven capacitor-coil. The target was then imploded by G-XII laser and heated by the PW-class LFEX laser. The heating efficiency was evaluated by measuring the number of Cu-K- α photons emitted. The heated core temperature was estimated by the X-ray intensity ratio of Cu Li-like and He-like emission lines. To understand the detailed dynamics of the core heating process, we carried out integrated simulations using the FI3 code system. Effects of magnetic fields on the implosion and electron beam transport, detailed core heating dynamics, and the resultant heating efficiency and core temperature will be presented. I will also discuss the prospect for an ignition-scale design of magnetized fast ignition using a solid ball target. This work is partially supported by JSPA KAKENHI Grant Number JP16H02245, JP26400532, JP15K21767, JP26400532, JP16K05638 and is performed with the support and the auspices of the NIFS Collaboration Research program (NIFS12KUGK057, NIFS15KUGK087).

  7. 20 CFR 631.31 - Monitoring and oversight.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TITLE III OF THE JOB TRAINING PARTNERSHIP ACT State Administration § 631.31 Monitoring and oversight. The Governor is responsible for monitoring and oversight of all State and substate grantee activities... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Monitoring and oversight. 631.31 Section 631...

  8. 20 CFR 631.31 - Monitoring and oversight.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... TITLE III OF THE JOB TRAINING PARTNERSHIP ACT State Administration § 631.31 Monitoring and oversight. The Governor is responsible for monitoring and oversight of all State and substate grantee activities... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Monitoring and oversight. 631.31 Section 631...

  9. 20 CFR 631.31 - Monitoring and oversight.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... TITLE III OF THE JOB TRAINING PARTNERSHIP ACT State Administration § 631.31 Monitoring and oversight. The Governor is responsible for monitoring and oversight of all State and substate grantee activities... 20 Employees' Benefits 3 2012-04-01 2012-04-01 false Monitoring and oversight. 631.31 Section 631...

  10. 76 FR 59394 - Big Eddy-Knight Transmission Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-26

    ...: Bonneville Power Administration (BPA), Department of Energy (DOE). ACTION: Notice of Availability of Record... that BPA has received by increasing BPA's 500-kV transmission capability to move power from the east...-kilovolt (kV) transmission line and ancillary facilities between BPA's existing Big Eddy Substation in The...

  11. 77 FR 26275 - Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-03

    ... Upgrade Project EIS AGENCY: Bonneville Power Administration (BPA), Department of Energy (DOE). ACTION... involvement. SUMMARY: BPA intends to prepare an EIS in accordance with the National Environmental Policy Act... consist of a combination of reinforcements of five existing BPA substations, placement of new conductor on...

  12. 6. Photocopy of Location, Site & Wall Sections drawing (from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photocopy of Location, Site & Wall Sections drawing (from the Bonneville Power Administration Engineering Vault, Portland, Oregon, Drawing C13-J2-342-D1, Sheet 1, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  13. 77 FR 22774 - Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ... Floodplain and Wetlands Involvement. SUMMARY: Western Area Power Administration currently owns and operates... floodplains and wetlands, so this Notice of Intent (NOI) also serves as a notice of proposed floodplain or wetland action in accordance with DOE floodplain and wetland environmental review requirements. DATES...

  14. 77 FR 1498 - Draft Environmental Assessment and Proposed Single-Species Habitat Conservation Plan for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    ... wind turbines and associated facilities and access roads, maintenance of the wind turbines and... include constructing and installing the wind turbines and associated electrical facilities and access... new 230- kilovolt substation (to be built on an existing pad), maintaining the new wind turbines and...

  15. 126. MOTOR CONTROL CENTER 1 (MCC1), FACING NORTH IN ROW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    126. MOTOR CONTROL CENTER 1 (MCC-1), FACING NORTH IN ROW OF ELECTRICAL CABINETS JUST SOUTH OF TRANSFORMER SUBSTATION CABINETS IN TRANSFORMER ROOM (112), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. GENERAL VIEW OF PUMPHOUSE FOUNDATIONS, ALSO SHOWING THREE PUMPS STILL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GENERAL VIEW OF PUMPHOUSE FOUNDATIONS, ALSO SHOWING THREE PUMPS STILL ON THE PAD, AND THE ELECTRICAL SUBSTATION IN LEFT MIDDLE DISTANCE - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Flame Deflector Water System, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  17. Field Trip.

    ERIC Educational Resources Information Center

    Sanders, Bill

    1993-01-01

    Reports the results of a field trip to measure the intensity of electromagnetic fields generated by electronic devices in the home, in cars, at work, outside, and in places people visit during the day. Found that a person gets more intense exposure while working at a computer than by living next to an electrical substation. (MDH)

  18. 19. DETAIL TO SOUTHEAST OF EXCITER 1 GIRARD TURBINE, SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. DETAIL TO SOUTHEAST OF EXCITER 1 GIRARD TURBINE, SHOWING BEVEL-GEARED REGISTER GATE CONTROLS, OLD POWERHOUSE BASEMENT - Trenton Falls Hydroelectric Station, Powerhouse & Substation, On west bank of West Canada Creek, along Trenton Falls Road, 1.25 miles north of New York Route 28, Trenton Falls, Oneida County, NY

  19. Within compound, looking northwest, Power Plant (Building 5761) and Guard ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Within compound, looking northwest, Power Plant (Building 5761) and Guard Tower (Building 5762) to left, Electrical Substation to right - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  20. Reversible Quantum Brownian Heat Engines for Electrons

    NASA Astrophysics Data System (ADS)

    Humphrey, T. E.; Newbury, R.; Taylor, R. P.; Linke, H.

    2002-08-01

    Brownian heat engines use local temperature gradients in asymmetric potentials to move particles against an external force. The energy efficiency of such machines is generally limited by irreversible heat flow carried by particles that make contact with different heat baths. Here we show that, by using a suitably chosen energy filter, electrons can be transferred reversibly between reservoirs that have different temperatures and electrochemical potentials. We apply this result to propose heat engines based on mesoscopic semiconductor ratchets, which can quasistatically operate arbitrarily close to Carnot efficiency.

  1. Reversible quantum heat engines for electrons

    NASA Astrophysics Data System (ADS)

    Linke, Heiner; Humphrey, Tammy E.; Newbury, Richard; Taylor, Richard P.

    2002-03-01

    Brownian heat engines use local temperature gradients in asymmetric potentials to move particles against an external force. The energy efficiency of such machines is generally limited by irreversible heat flow carried by particles that make contact with different heat baths. Here we show that, by using a suitably chosen energy filter, electrons can be transferred reversibly between reservoirs that have different temperatures and electrochemical potentials. We apply this result to propose heat engines based on quantum ratchets, which can quasistatically operate at Carnot efficiency.

  2. A thermoacoustic-Stirling heat engine: detailed study

    PubMed

    Backhaus; Swift

    2000-06-01

    A new type of thermoacoustic engine based on traveling waves and ideally reversible heat transfer is described. Measurements and analysis of its performance are presented. This new engine outperforms previous thermoacoustic engines, which are based on standing waves and intrinsically irreversible heat transfer, by more than 50%. At its most efficient operating point, it delivers 710 W of acoustic power to its resonator with a thermal efficiency of 0.30, corresponding to 41% of the Carnot efficiency. At its most powerful operating point, it delivers 890 W to its resonator with a thermal efficiency of 0.22. The efficiency of this engine can be degraded by two types of acoustic streaming. These are suppressed by appropriate tapering of crucial surfaces in the engine and by using additional nonlinearity to induce an opposing time-averaged pressure difference. Data are presented which show the nearly complete elimination of the streaming convective heat loads. Analysis of these and other irreversibilities show which components of the engine require further research to achieve higher efficiency. Additionally, these data show that the dynamics and acoustic power flows are well understood, but the details of the streaming suppression and associated heat convection are only qualitatively understood.

  3. Influence of the ambient temperature on the cooling efficiency of the high performance cooling device with thermosiphon effect

    NASA Astrophysics Data System (ADS)

    Nemec, Patrik; Malcho, Milan

    2018-06-01

    This work deal with experimental measurement and calculation cooling efficiency of the cooling device working with a heat pipe technology. The referred device in the article is cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description, working principle and construction of cooling device. The main factor affected the dissipation of high heat flux from electronic elements through the cooling device to the surrounding is condenser construction, its capacity and option of heat removal. Experimental part describe the measuring method cooling efficiency of the cooling device depending on ambient temperature in range -20 to 40°C and at heat load of electronic components 750 W. Measured results are compared with results calculation based on physical phenomena of boiling, condensation and natural convection heat transfer.

  4. New configurations of a heat recovery absorption heat pump integrated with a natural gas boiler for boiler efficiency improvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, Ming; Abdelaziz, Omar; Yin, Hongxi

    2014-11-01

    Conventional natural gas-fired boilers exhaust flue gas direct to the atmosphere at 150 200 C, which, at such temperatures, contains large amount of energy and results in relatively low thermal efficiency ranging from 70% to 80%. Although condensing boilers for recovering the heat in the flue gas have been developed over the past 40 years, their present market share is still less than 25%. The major reason for this relatively slow acceptance is the limited improvement in the thermal efficiency of condensing boilers. In the condensing boiler, the temperature of the hot water return at the range of 50 60more » C, which is used to cool the flue gas, is very close to the dew point of the water vapor in the flue gas. Therefore, the latent heat, the majority of the waste heat in the flue gas, which is contained in the water vapor, cannot be recovered. This paper presents a new approach to improve boiler thermal efficiency by integrating absorption heat pumps with natural gas boilers for waste heat recovery (HRAHP). Three configurations of HRAHPs are introduced and discussed. The three configurations are modeled in detail to illustrate the significant thermal efficiency improvement they attain. Further, for conceptual proof and validation, an existing hot water-driven absorption chiller is operated as a heat pump at operating conditions similar to one of the devised configurations. An overall system performance and economic analysis are provided for decision-making and as evidence of the potential benefits. These three configurations of HRAHP provide a pathway to achieving realistic high-efficiency natural gas boilers for applications with process fluid return temperatures higher than or close to the dew point of the water vapor in the flue gas.« less

  5. Analysis of hybrid electric/thermofluidic inputs for wet shape memory alloy actuators

    NASA Astrophysics Data System (ADS)

    Flemming, Leslie; Mascaro, Stephen

    2013-01-01

    A wet shape memory alloy (SMA) actuator is characterized by an SMA wire embedded within a compliant fluid-filled tube. Heating and cooling of the SMA wire produces a linear contraction and extension of the wire. Thermal energy can be transferred to and from the wire using combinations of resistive heating and free/forced convection. This paper analyzes the speed and efficiency of a simulated wet SMA actuator using a variety of control strategies involving different combinations of electrical and thermofluidic inputs. A computational fluid dynamics (CFD) model is used in conjunction with a temperature-strain model of the SMA wire to simulate the thermal response of the wire and compute strains, contraction/extension times and efficiency. The simulations produce cycle rates of up to 5 Hz for electrical heating and fluidic cooling, and up to 2 Hz for fluidic heating and cooling. The simulated results demonstrate efficiencies up to 0.5% for electric heating and up to 0.2% for fluidic heating. Using both electric and fluidic inputs concurrently improves the speed and efficiency of the actuator and allows for the actuator to remain contracted without continually delivering energy to the actuator, because of the thermal capacitance of the hot fluid. The characterized speeds and efficiencies are key requirements for implementing broader research efforts involving the intelligent control of electric and thermofluidic networks to optimize the speed and efficiency of wet actuator arrays.

  6. Automatic temperature adjustment apparatus

    DOEpatents

    Chaplin, James E.

    1985-01-01

    An apparatus for increasing the efficiency of a conventional central space heating system is disclosed. The temperature of a fluid heating medium is adjusted based on a measurement of the external temperature, and a system parameter. The system parameter is periodically modified based on a closed loop process that monitors the operation of the heating system. This closed loop process provides a heating medium temperature value that is very near the optimum for energy efficiency.

  7. Boiling and quenching heat transfer advancement by nanoscale surface modification.

    PubMed

    Hu, Hong; Xu, Cheng; Zhao, Yang; Ziegler, Kirk J; Chung, J N

    2017-07-21

    All power production, refrigeration, and advanced electronic systems depend on efficient heat transfer mechanisms for achieving high power density and best system efficiency. Breakthrough advancement in boiling and quenching phase-change heat transfer processes by nanoscale surface texturing can lead to higher energy transfer efficiencies, substantial energy savings, and global reduction in greenhouse gas emissions. This paper reports breakthrough advancements on both fronts of boiling and quenching. The critical heat flux (CHF) in boiling and the Leidenfrost point temperature (LPT) in quenching are the bottlenecks to the heat transfer advancements. As compared to a conventional aluminum surface, the current research reports a substantial enhancement of the CHF by 112% and an increase of the LPT by 40 K using an aluminum surface with anodized aluminum oxide (AAO) nanoporous texture finish. These heat transfer enhancements imply that the power density would increase by more than 100% and the quenching efficiency would be raised by 33%. A theory that links the nucleation potential of the surface to heat transfer rates has been developed and it successfully explains the current finding by revealing that the heat transfer modification and enhancement are mainly attributed to the superhydrophilic surface property and excessive nanoscale nucleation sites created by the nanoporous surface.

  8. Energy Savers: Tips on Saving Money & Energy at Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  9. Energy Saver: Tips on Saving Money & Energy at Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  10. Wound tube heat exchanger

    DOEpatents

    Ecker, Amir L.

    1983-01-01

    What is disclosed is a wound tube heat exchanger in which a plurality of tubes having flattened areas are held contiguous adjacent flattened areas of tubes by a plurality of windings to give a double walled heat exchanger. The plurality of windings serve as a plurality of effective force vectors holding the conduits contiguous heat conducting walls of another conduit and result in highly efficient heat transfer. The resulting heat exchange bundle is economical and can be coiled into the desired shape. Also disclosed are specific embodiments such as the one in which the tubes are expanded against their windings after being coiled to insure highly efficient heat transfer.

  11. Simulation and energy analysis of distributed electric heating system

    NASA Astrophysics Data System (ADS)

    Yu, Bo; Han, Shenchao; Yang, Yanchun; Liu, Mingyuan

    2018-02-01

    Distributed electric heating system assistssolar heating systemby using air-source heat pump. Air-source heat pump as auxiliary heat sourcecan make up the defects of the conventional solar thermal system can provide a 24 - hour high - efficiency work. It has certain practical value and practical significance to reduce emissions and promote building energy efficiency. Using Polysun software the system is simulated and compared with ordinary electric boiler heating system. The simulation results show that upon energy request, 5844.5kW energy is saved and 3135kg carbon - dioxide emissions are reduced and5844.5 kWhfuel and energy consumption is decreased with distributed electric heating system. Theeffect of conserving energy and reducing emissions using distributed electric heating systemis very obvious.

  12. Thermo-aerodynamic efficiency of non-circular ducts with vortex enhancement of heat exchange in different types of compact heat exchangers

    NASA Astrophysics Data System (ADS)

    Vasilev, V. Ya; Nikiforova, S. A.

    2018-03-01

    Experimental studies of thermo-aerodynamic characteristics of non-circular ducts with discrete turbulators on walls and interrupted channels have confirmed the rational enhancement of convective heat transfer, in which the growth of heat transfer outstrips or equals the growth of aerodynamic losses. Determining the regularities of rational (energy-saving) enhancement of heat transfer and the proposed method for comparing the characteristics of smooth-channel (without enhancement) heat exchangers with effective analogs provide new results, confirming the high efficiency of vortex enhancement of convective heat transfer in non-circular ducts of plate-finned heat exchange surfaces. This allows creating heat exchangers with much smaller mass and volume for operation in energy-saving modes.

  13. Thermodynamics of the mesoscopic thermoelectric heat engine beyond the linear-response regime.

    PubMed

    Yamamoto, Kaoru; Hatano, Naomichi

    2015-10-01

    Mesoscopic thermoelectric heat engine is much anticipated as a device that allows us to utilize with high efficiency wasted heat inaccessible by conventional heat engines. However, the derivation of the heat current in this engine seems to be either not general or described too briefly, even inappropriately in some cases. In this paper, we give a clear-cut derivation of the heat current of the engine with suitable assumptions beyond the linear-response regime. It resolves the confusion in the definition of the heat current in the linear-response regime. After verifying that we can construct the same formalism as that of the cyclic engine, we find the following two interesting results within the Landauer-Büttiker formalism: the efficiency of the mesoscopic thermoelectric engine reaches the Carnot efficiency if and only if the transmission probability is finite at a specific energy and zero otherwise; the unitarity of the transmission probability guarantees the second law of thermodynamics, invalidating Benenti et al.'s argument in the linear-response regime that one could obtain a finite power with the Carnot efficiency under a broken time-reversal symmetry [Phys. Rev. Lett. 106, 230602 (2011)]. These results demonstrate how quantum mechanics constrains thermodynamics.

  14. Investigation of an ejector heat pump by analytical methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, C.T.

    1984-07-01

    Using existing theories of ejector design, the optimum geometry of a high-efficiency ejector - including mixing section cross-sectional area, mass flow entrainment rate, ejector efficiency, and overall COP - for a heat pump cycle was determined. A parametric study was performed to evaluate the COP values for different operating conditions. A sensitivity study determined th effects of nozzle efficiency and diffuser efficiency on the overall ejector heat pump COP. The off-design study estimated the COP for an ejector heat pump operating at off-design conditions. Refrigerants 11, 113, and 114 are three of the halocarbons which best satisfy the criteria formore » an ejector heat pump system. The estimated COPs were 0.3 for the cooling mode and 1.3 for the heating mode at standard operating conditions: a boiler temperature of 93.3/sup 0/C (200/sup 0/F), a condenser temperature of 43.3/sup 0/C (110/sup 0/F), and an evaporator temperature of 10/sup 0/C (50/sup 0/F). Based on the same operating conditions, an optimum ejector geometry was estimated for each of the refrigerants R-11 and R-113. Since the COP values for heating obtained in this analysis are greater than unity, the performance of an ejector heat pump operating in the heating mode should be competitive with that of oil- or gas-fired furnaces or electrical resistance heaters.« less

  15. Regenerative Hydride Heat Pump

    NASA Technical Reports Server (NTRS)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  16. Heat Transfer and Friction Characteristics of Artificially Roughened Duct used for Solar Air Heaters—a Review

    NASA Astrophysics Data System (ADS)

    Kumar, Khushmeet; Prajapati, D. R.; Samir, Sushant

    2018-02-01

    Solar air heater uses the energy coming from the sun to heat the air. The conversion rate of solar energy to heat depends upon the efficiency of the solar air heater and this efficiency can be increased by the use of artificial roughness on the surface of absorber plate. Various studies were carried out to analyse the effect of different roughness geometries on heat transfer and friction factor characteristics. The thermo-hydraulic performance of solar air heater can be evaluated in terms of effective efficiency, thermo-hydraulic performance parameter and exergetic efficiency. In this study various geometries used for artificial roughness and to improve the performance of solar air heaters were studied. Also correlations developed by various researchers are presented in this paper.

  17. Efficiencies and coefficients of performance of heat engines, refrigerators, and heat pumps with friction: a universal limiting behavior.

    PubMed

    Bizarro, João P S; Rodrigues, Paulo

    2012-11-01

    For work-producing heat engines, or work-consuming refrigerators and heat pumps, the percentage decrease caused by friction in their efficiencies, or coefficients of performance (COP's), is approximately given by the ratio W(fric)/W between the work spent against friction forces and the work performed by, or delivered to, the working fluid. This universal scaling, which applies in the limit of small friction (W(fric)/W

  18. High Efficiency Heat Exchanger for High Temperature and High Pressure Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sienicki, James J.; Lv, Qiuping; Moisseytsev, Anton

    CompRex, LLC (CompRex) specializes in the design and manufacture of compact heat exchangers and heat exchange reactors for high temperature and high pressure applications. CompRex’s proprietary compact technology not only increases heat exchange efficiency by at least 25 % but also reduces footprint by at least a factor of ten compared to traditional shell-and-tube solutions of the same capacity and by 15 to 20 % compared to other currently available Printed Circuit Heat Exchanger (PCHE) solutions. As a result, CompRex’s solution is especially suitable for Brayton cycle supercritical carbon dioxide (sCO2) systems given its high efficiency and significantly lower capitalmore » and operating expenses. CompRex has already successfully demonstrated its technology and ability to deliver with a pilot-scale compact heat exchanger that was under contract by the Naval Nuclear Laboratory for sCO2 power cycle development. The performance tested unit met or exceeded the thermal and hydraulic specifications with measured heat transfer between 95 to 98 % of maximum heat transfer and temperature and pressure drop values all consistent with the modeled values. CompRex’s vision is to commercialize its compact technology and become the leading provider for compact heat exchangers and heat exchange reactors for various applications including Brayton cycle sCO2 systems. One of the limitations of the sCO2 Brayton power cycle is the design and manufacturing of efficient heat exchangers at extreme operating conditions. Current diffusion-bonded heat exchangers have limitations on the channel size through which the fluid travels, resulting in excessive solid material per heat exchanger volume. CompRex’s design allows for more open area and shorter fluid proximity for increased heat transfer efficiency while sustaining the structural integrity needed for the application. CompRex is developing a novel improvement to its current heat exchanger design where fluids are directed to alternating channels so that each fluid is fully surrounded by the opposing fluid. As compared to similar existing compact heat exchangers, the new design converts most secondary surface area to primary surface area, eliminating fin inefficiencies. CompRex requests that all technical information about the heat exchanger designs be protected as proprietary information. To honor that request, only non-proprietay summaries are included in this report.« less

  19. Absorption heat pump system

    DOEpatents

    Grossman, Gershon; Perez-Blanco, Horacio

    1984-01-01

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  20. The technological raw material heating furnaces operation efficiency improving issue

    NASA Astrophysics Data System (ADS)

    Paramonov, A. M.

    2017-08-01

    The issue of fuel oil applying efficiency improving in the technological raw material heating furnaces by means of its combustion intensification is considered in the paper. The technical and economic optimization problem of the fuel oil heating before combustion is solved. The fuel oil heating optimal temperature defining method and algorithm analytically considering the correlation of thermal, operating parameters and discounted costs for the heating furnace were developed. The obtained optimization functionality provides the heating furnace appropriate thermal indices achievement at minimum discounted costs. The carried out research results prove the expediency of the proposed solutions using.