Sample records for hemolysis assay showed

  1. Discriminating the hemolytic risk of blood type A plasmas using the complement hemolysis using human erythrocytes (CHUHE) assay.

    PubMed

    Cunnion, Kenji M; Hair, Pamela S; Krishna, Neel K; Sass, Megan A; Enos, Clinton W; Whitley, Pamela H; Maes, Lanne Y; Goldberg, Corinne L

    2017-03-01

    The agglutination-based cross-matching method is sensitive for antibody binding to red blood cells but is only partially predictive of complement-mediated hemolysis, which is important in many acute hemolytic transfusion reactions. Here, we describe complement hemolysis using human erythrocytes (CHUHE) assays that directly evaluate complement-mediated hemolysis between individual serum-plasma and red blood cell combinations. The CHUHE assay is used to evaluate correlations between agglutination titers and complement-mediated hemolysis as well as the hemolytic potential of plasma from type A blood donors. Plasma or serum from each type A blood donor was incubated with AB or B red blood cells in the CHUHE assay and measured for free hemoglobin release. CHUHE assays for serum or plasma demonstrate a wide, dynamic range and high sensitivity for complement-mediated hemolysis for individual serum/plasma and red blood cell combinations. CHUHE results suggest that agglutination assays alone are only moderately predictive of complement-mediated hemolysis. CHUHE results also suggest that plasma from particular type A blood donors produce minimal complement-mediated hemolysis, whereas plasma from other type A blood donors produce moderate to high-level complement-mediated hemolysis, depending on the red blood cell donor. The current results indicate that the CHUHE assay can be used to assess complement-mediated hemolysis for plasma or serum from a type A blood donor, providing additional risk discrimination over agglutination titers alone. © 2016 AABB.

  2. A Novel Stopped-Flow Assay for Quantitating Carbonic-Anhydrase Activity and Assessing Red-Blood-Cell Hemolysis.

    PubMed

    Zhao, Pan; Geyer, R Ryan; Boron, Walter F

    2017-01-01

    We report a novel carbonic-anhydrase (CA) assay and its use for quantitating red-blood-cell (RBC) lysis during stopped-flow (SF) experiments. We combine two saline solutions, one containing HEPES/pH 7.03 and the other, ~1% CO 2 /44 mM [Formula: see text]/pH 8.41, to generate an out-of-equilibrium CO 2 /[Formula: see text] solution containing ~0.5% CO 2 /22 [Formula: see text]/pH ~7.25 (10°C) in the SF reaction cell. CA catalyzes relaxation of extracellular pH to ~7.50: [Formula: see text] + H + → CO 2 + H 2 O. Proof-of-concept studies (no intact RBCs) show that the pH-relaxation rate constant ( k ΔpH )-measured via pyranine fluorescence-rises linearly with increases in [bovine CAII] or [murine-RBC lysate]. The y-intercept (no CA) was k ΔpH = 0.0183 s -1 . Combining increasing amounts of murine-RBC lysate with ostensibly intact RBCs (pre-SF hemolysis ≅0.4%)-fixing total [hemoglobin] at 2.5 μM in the reaction cell to simulate hemolysis from ostensibly 0 to 100%-causes k ΔpH to increase linearly. This y-intercept (0% lysate/100% ostensibly intact RBCs) was k ΔpH = 0.0820 s -1 , and the maximal k ΔpH (100% lysate/0% intact RBCs) was 1.304 s -1 . Thus, mean percent hemolysis in the reaction cell was ~4.9%. Phenol-red absorbance assays yield indistinguishable results. The increase from 0.4 to 4.9% presumably reflects mechanical RBC disruption during rapid mixing. In all fluorescence studies, the CA blocker acetazolamide reduces k ΔpH to near-uncatalyzed values, implying that all CA activity is extracellular. Our lysis assay is simple, sensitive, and precise, and will be valuable for correcting for effects of lysis in physiological SF experiments. The underlying CA assay, applied to blood plasma, tissue-culture media, and organ perfusates could assess lysis in a variety of applications.

  3. A Novel Stopped-Flow Assay for Quantitating Carbonic-Anhydrase Activity and Assessing Red-Blood-Cell Hemolysis

    PubMed Central

    Zhao, Pan; Geyer, R. Ryan; Boron, Walter F.

    2017-01-01

    We report a novel carbonic-anhydrase (CA) assay and its use for quantitating red-blood-cell (RBC) lysis during stopped-flow (SF) experiments. We combine two saline solutions, one containing HEPES/pH 7.03 and the other, ~1% CO2/44 mM HCO3-/pH 8.41, to generate an out-of-equilibrium CO2/HCO3- solution containing ~0.5% CO2/22 HCO3-/pH ~7.25 (10°C) in the SF reaction cell. CA catalyzes relaxation of extracellular pH to ~7.50: HCO3- + H+ → CO2 + H2O. Proof-of-concept studies (no intact RBCs) show that the pH-relaxation rate constant (kΔpH)—measured via pyranine fluorescence—rises linearly with increases in [bovine CAII] or [murine-RBC lysate]. The y-intercept (no CA) was kΔpH = 0.0183 s−1. Combining increasing amounts of murine-RBC lysate with ostensibly intact RBCs (pre-SF hemolysis ≅0.4%)—fixing total [hemoglobin] at 2.5 μM in the reaction cell to simulate hemolysis from ostensibly 0 to 100%—causes kΔpH to increase linearly. This y-intercept (0% lysate/100% ostensibly intact RBCs) was kΔpH = 0.0820 s−1, and the maximal kΔpH (100% lysate/0% intact RBCs) was 1.304 s−1. Thus, mean percent hemolysis in the reaction cell was ~4.9%. Phenol-red absorbance assays yield indistinguishable results. The increase from 0.4 to 4.9% presumably reflects mechanical RBC disruption during rapid mixing. In all fluorescence studies, the CA blocker acetazolamide reduces kΔpH to near-uncatalyzed values, implying that all CA activity is extracellular. Our lysis assay is simple, sensitive, and precise, and will be valuable for correcting for effects of lysis in physiological SF experiments. The underlying CA assay, applied to blood plasma, tissue-culture media, and organ perfusates could assess lysis in a variety of applications. PMID:28400735

  4. Pathogenesis and mechanisms of antibody-mediated hemolysis

    PubMed Central

    Flegel, Willy A

    2015-01-01

    Background The clinical consequences of antibodies to red blood cells (RBC) have been studied for a century. Most clinically relevant antibodies can be detected by sensitive in vitro assays. Several mechanisms of antibody-mediated hemolysis are well understood. Such hemolysis following transfusion is reliably avoided in a donor/recipient pair, if one individual is negative for the cognate antigen to which the other has the antibody. Study design and results Mechanisms of antibody-mediated hemolysis were reviewed based on a presentation at the Strategies to Address Hemolytic Complications of Immune Globulin Infusions Workshop addressing intravenous immunoglobulin (IVIG) and ABO antibodies. The presented topics included the rates of intravascular and extravascular hemolysis; IgM and IgG isoagglutinins; auto- and alloantibodies; antibody specificity; A, B, A,B and A1 antigens; A1 versus A2 phenotypes; monocytes/macrophages, other immune cells and complement; monocyte monolayer assay (MMA); antibody-dependent cell-mediated cytotoxicity (ADCC); and transfusion reactions due to ABO and other antibodies. Conclusion Several clinically relevant questions remained unresolved, and diagnostic tools were lacking to routinely and reliably predict the clinical consequences of RBC antibodies. Most hemolytic transfusion reactions associated with IVIG were due to ABO antibodies. Reducing the titers of such antibodies in IVIG may lower the frequency of this kind of adverse event. The only way to stop these events is to have no anti-A or anti-B antibodies in the IVIG products. PMID:26174897

  5. Hemolysis induced by PMIVSD occluder.

    PubMed

    Rao, D Sheshagiri; Barik, Ramachandra; Siva Prasad, Akula

    2016-09-01

    Hemolysis related to occluder, prosthetic valve, and prosthetic ring used for mitral valve annuloplasty are not very unusual. However, hemolysis related to transcathetor closure of post-myocardial infarction ventricular septal defect (PMIVSD) is infrequent. A close follow-up for spontaneous resolution with or without blood transfusion has been reported in a few cases. Occasionally, surgical retrieval is unavoidable or lifelong blood transfusion is required if surgery cannot be done because of higher risk. In this illustration, we have showed a close follow-up of a case of hemolysis induced by atrial septal occluder used for VSD closure after myocardial infarction. Despite successful device closure of PMIVSD which is difficult, a close watch is needed for complications like residual leak, device embolization, and hemolysis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  6. Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration.

    PubMed

    Killilea, David W; Rohner, Fabian; Ghosh, Shibani; Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H; King, Janet C

    2017-06-01

    Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1-2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions.

  7. Erythrocyte hemolysis by detergents.

    PubMed

    Chernitsky, E A; Senkovich, O A

    1997-01-01

    The numbers of Triton X-100 and sodium dodecyl sulfate molecules required to form respective pores were estimated from the relationship between the detergent concentrations and the rates of fast and slow hemolysis components. It has been found that the slow hemolysis component evoked by Triton X-100 is related to the existence of two different pores. It is shown that the fast hemolysis component induced by sodium dodecyl sulfate is associated with the modification of phosphatidylcholine which determines the break in the Arrhenius plots of the hemolysis rate within the range of 20 degrees C. The shape of hemolysis kinetic curves and the dependence of hemolytic parameters on the detergent concentration and temperature are discussed based on the concept of hemolysis caused by the formation of pores in various membrane lipid regions and by releasing vesicles from erythrocytes.

  8. Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration123

    PubMed Central

    Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H

    2017-01-01

    Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1–2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions. PMID

  9. Dependence of erythrocyte vesiculation and hemolysis parameters on the concentration of sodium dodecyl sulfate. Vesicular-competitive hemolysis.

    PubMed

    Chernitsky, E A; Senkovich, O A; Rozin, V V

    2001-07-01

    The kinetic and concentration dependences of erythrocyte vesiculation and hemolysis induced by sodium dodecyl sulfate were studied. The similarity of the slopes of the dose dependence of the SDS-induced vesiculation and slow hemolysis rates in the double logarithmic coordinates suggested a close relation between the processes of vesiculation and pore formation for slow hemolysis by the detergent. Further evidence of the competitive nature of the detergent-induced vesiculation and fast hemolysis by sodium dodecyl sulfate was obtained. The phenomenon of partial hemolysis proceeding at a rate comparable to that of cell vesiculation is explained in terms of the competition between hemolysis and vesiculation, without resorting to erythrocyte heterogeneity. New vesicular-competitive hemolysis is described. Based on it, the action of different hemolysis-inducing agents is analysed.

  10. Universal pooled plasma (Uniplas(®)) does not induce complement-mediated hemolysis of human red blood cells in vitro.

    PubMed

    Heger, Andrea; Brandstätter, Hubert; Prager, Bettina; Brainovic, Janja; Cortes, Rhoda; Römisch, Jürgen

    2015-02-01

    Pooling of plasma of different blood groups before large scale manufacturing of Uniplas(®) results in the formation of low levels of soluble immune complexes (CIC). The aim of this study was to investigate the level and removal of CIC during Uniplas(®) manufacturing. In addition, an in vitro hemolysis assay should be developed and investigate if Uniplas(®) does induce complement-mediated hemolysis of human red blood cells (RBC). In-process samples from Uniplas(®) (universal plasma) and Octaplas(LG)(®) (blood group specific plasma) routine manufacturing batches were tested on CIC using commercially available ELISA test kits. In addition, CIC was produced by admixing heat-aggregated immunoglobulins or monoclonal anti-A/anti-B antibodies to plasma and removal of CIC was followed in studies of the Uniplas(®) manufacturing process under down-scale conditions. The extent of RBC lysis was investigated in plasma samples using the in-house hemolysis assay. Levels of CIC in Uniplas(®) are within the normal ranges for plasma and comparable to that found in Octaplas(LG)(®). Down-scale experiments showed that both IgG/IgM-CIC levels are significantly removed on average by 40-50% during Uniplas(®) manufacturing. Uniplas(®) does not induce hemolysis of RBCs in vitro. Hemolysis occurs only after spiking with high titers of anti-A/anti-B antibodies and depends on the antibody specificity (i.e. titer) in the plasma sample. The results of this study confirm the safety of Uniplas(®) regarding transfusion to patients of all ABO blood groups. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Raised erythrocyte creatine in patients with pulmonary arterial hypertension--evidence for subclinical hemolysis.

    PubMed

    Fox, Benjamin D; Okumiya, Toshika; Attas-Fox, Liat; Kassirer, Michael; Raviv, Yael; Kramer, Mordechai R

    2012-04-01

    Pulmonary arterial hypertension (PAH) has been associated with hemolytic conditions such as sickle cell disease but the possible role of hemolysis in the pathogenesis or pathophysiology of other forms of PAH has not been studied. Erythrocyte lifespan is the gold-standard test of hemolysis and may be measured by assaying erythrocyte creatine (EC) levels. EC decreases as the erythrocyte ages, so patients with hemolysis have high EC levels. We measured EC and other parameters of hemolysis in patients with idiopathic and connective tissue associated PAH and normal controls. In patients with PAH (n = 40), EC levels were higher than in controls n = 30 (patients EC 1.72 mcmol/g HgB 95%CI[1.51, 1.96], controls EC 1.05 mcmol/g HgB [0.93, 1.19], p < 0.0001). High levels of EC correlated with worse 6 min walk (r = -0.42, p < 0.0001) and worse functional class (p = 0.002). Other indirect indices of hemolysis (total lactate dehydrogenase, red cell distribution width) were also increased in patients with PAH relative to controls. There is evidence of subclinical hemolysis in patients with PAH, and higher levels of hemolysis are associated with poorer exercise capacity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Cell-based evaluation of a novel Dictyophora indusiata polysaccharide against oxidative-induced erythrocyte hemolysis.

    PubMed

    Liao, W; Chen, L; Yu, B; Lei, Z; Wu, X; Yang, J; Ren, J

    2016-01-11

    The protective effect of a polysaccharide from Dictyophora indusiata(DP1)against oxidative hemolysis was comprehensively evaluated. The 2, 2-azobis (2-amidino-propane) dihydrochloride (AAPH)-induced erythrocyte hemolysis assay showed that DP1 exhibited excellent anti-hemolytic activity(87.4% hemolysis suppression ratio at 20 nmol/mL). Also, the formation of conjugated diene induced by cupric chloride (CuCl2) in plasma was significantly inhibited by DP1. Besides, DP1 could effectively inhibit AAPH-induced overproduction of reactive oxygen species (81.5% inhibition at 20 nmol/mL) and alleviated the enhancement of intracellular antioxidant enzymes including superoxide dismutase(SOD), glutathione peroxidase (GPX) and catalase (CAT) activities. Also, the malondialdehyde (MDA) formation caused by oxidative stress was suppressed by 57.0% at DP1 concentration of 20 nmol/mL. Taken together, the possible intracellular antioxidant detoxifying mechanism of DP1 was probably via preserving the activities of the antioxidant enzymes (SOD, GPx and CAT) as well as inhibiting lipid peroxidation, and thus alleviated erythrocytes oxidation and plasma oxidation.

  13. Mechanisms of anionic detergent-induced hemolysis.

    PubMed

    Chernitsky, E; Senkovich, O

    1998-09-01

    The effect of osmotic protectors (sucrose and polyethylene glycols) and of a decrease in the detergent concentration at different points of hemolysis of human erythrocytes by sodium dodecyl sulphate on the shape of kinetic curves of hemolysis were studied. It is shown that slow detergent-induced hemolysis follows the colloid-osmotic mechanisms. Evidence is provided that rapid hemolysis by sodium dodecyl sulphate is caused by opening of large pores sufficient for the release of hemoglobin molecules rather than by the colloid-osmotic mechanism, and that the kinetics of hemolysis is mainly determined by time dependence of the opening probability of these pores.

  14. Evaluation of the automated hematology analyzer ADVIA® 120 for cerebrospinal fluid analysis and usage of unique hemolysis reagent.

    PubMed

    Tanada, H; Ikemoto, T; Masutani, R; Tanaka, H; Takubo, T

    2014-02-01

    In this study, we evaluated the performance of the ADVIA 120 hematology system for cerebrospinal fluid (CSF) assay. Cell counts and leukocyte differentials in CSF were examined with the ADVIA 120 hematology system, while simultaneously confirming an effective hemolysis agent for automated CSF cell counts. The detection limits of both white blood cell (WBC) counts and red blood cell (RBC) counts on the measurement of CSF cell counts by the ADVIA 120 hematology system were superior at 2 cells/μL (10(-6) L). The WBC count was linear up to 9.850 cells/μL, and the RBC count was linear up to approximately 20 000 cells/μL. The intrarun reproducibility indicated good precision. The leukocyte differential of CSF cells, performed by the ADVIA120 hematology system, showed good correlation with the microscopic procedure. The VersaLyse hemolysis solution efficiently lysed the samples without interfering with cell counts and leukocyte differential, even in a sample that included approximately 50 000/μL RBC. These data show the ADVIA 120 hematology system correctly measured the WBC count and leukocyte differential in CSF. The VersaLyse hemolysis solution is considered to be optimal for hemolysis treatment of CSF when measuring cell counts and differentials by the ADVIA 120 hematology system. © 2013 John Wiley & Sons Ltd.

  15. Evaluation of Intravascular Hemolysis With Erythrocyte Creatine in Patients With Aortic Stenosis.

    PubMed

    Sugiura, Tetsuro; Okumiya, Toshika; Kubo, Toru; Takeuchi, Hiroaki; Matsumura, Yoshihisa

    2016-07-27

    Chronic intravascular hemolysis has been identified in patients with cardiac valve prostheses, but only a few case reports have evaluated intravascular hemolysis in patients with native valvular heart disease. To detect intravascular hemolysis in patients with aortic stenosis, erythrocyte creatine was evaluated with hemodynamic indices obtained by echocardiography.Erythrocyte creatine, a marker of erythrocyte age, was assayed in 30 patients with aortic stenosis and 10 aged matched healthy volunteers. Peak flow velocity of the aortic valve was determined by continuous-wave Doppler echocardiography. Twenty of 30 patients with aortic stenosis had high erythrocyte creatine levels (> 1.8 µmol/g Hb) and erythrocyte creatine was significantly higher as compared with control subjects (1.98 ± 0.49 versus 1.52 ± 0.19 µmol/g Hb, P = 0.007). Peak transvalvular pressure gradient ranged from 46 to 142 mmHg and peak flow velocity ranged from 3.40 to 5.95 m/second. Patients with aortic stenosis had a significantly lower erythrocyte count (387 ± 40 versus 436 ± 42 × 10(4) µL, P = 0.002) and hemoglobin (119 ± 11 versus 135 ± 11 g/L, P < 0.001) as compared with control subjects. Erythrocyte creatine had a fair correlation with peak flow velocity (r = 0.55, P = 0.002).In conclusion, intravascular hemolysis due to destruction of erythrocytes was detected in patients with moderate to severe aortic stenosis and the severity of intravascular hemolysis was related to valvular flow velocity of the aortic valve.

  16. [Hemolysis Performance Analysis of the Centrifugal Maglev Blood Pump].

    PubMed

    Wang, Yiwen; Zhang, Fan; Fang, Yuan; Dong, Baichuan; Zhou, Liang

    2016-05-01

    In order to analyze and study the hemolysis performance of the centrifugal maglev blood pump, which was designed by ourselves, this paper built the mathematical model and computational fluid dynamics analyzed it using Fluent. Then we set up the in vitro hemolysis experiment platform, in case of the design condition, the content of free hemoglobin and hematocrit in plasma were measured in a certain time interval, and calculated the normalized index of hemolysis of the blood pump. The numerical simulation results show the internal static pressure distribution is smooth inside the pump, the wal shear stress inside the pump is less than 150 Pa. Therefore, the red blood cel damage and exposure time is independent. The normalized index of hemolysis is (0.002 9±0.000 7) mg/L, which is in accordance with human physiological requirement.

  17. Blood Warming and Hemolysis: A Systematic Review With Meta-Analysis.

    PubMed

    Poder, Thomas G; Nonkani, Wendyam G; Tsakeu Leponkouo, Élyonore

    2015-07-01

    The use of fluid warmers during blood transfusion is recommended to avoid inducing hypothermia and its harmful effects. Fluid warmers offered by manufacturers can reach temperatures of 43°C. However, the recommendations of national regulatory organizations do not clearly indicate the maximum heating temperature in relation to the risk of hemolysis. To fill this gap, we conducted a systematic review of the literature with meta-analysis. To match clinical practice, this review was limited to fluid warmers that used contact heating; thus, studies that used radiofrequency or microwave heating were excluded. Twenty-four observational studies were included, 17 of which were the subject of a meta-analysis. A preliminary descriptive analysis indicated that multiple factors can influence the level of hemolysis during blood heating with a liquid warmer, including blood age, anticoagulant type, duration of exposure to heat, stirring the blood during heating, and various elements of the circuit through which blood flows (eg, type of infusion pump with pressure and flow, type of microfilter, and type of tubing). Moreover, the duration between sampling and hemolysis assay was a source of heterogeneity among studies, as were the initial free hemoglobin levels in the various experiments. In general, the increase generated by each of these factors other than temperature appears to have been limited except for blood age, which is an important parameter of hemolysis, the length of exposure to heat, and, in some studies, the type of infusion pump used. Regarding the meta-analysis, at temperatures at or less than 43°C and even up to 45-46°C, it appears that blood heating is safe and causes hemolysis only in clinically negligible proportions. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. A Review of Hemolysis Prediction Models for Computational Fluid Dynamics.

    PubMed

    Yu, Hai; Engel, Sebastian; Janiga, Gábor; Thévenin, Dominique

    2017-07-01

    Flow-induced hemolysis is a crucial issue for many biomedical applications; in particular, it is an essential issue for the development of blood-transporting devices such as left ventricular assist devices, and other types of blood pumps. In order to estimate red blood cell (RBC) damage in blood flows, many models have been proposed in the past. Most models have been validated by their respective authors. However, the accuracy and the validity range of these models remains unclear. In this work, the most established hemolysis models compatible with computational fluid dynamics of full-scale devices are described and assessed by comparing two selected reference experiments: a simple rheometric flow and a more complex hemodialytic flow through a needle. The quantitative comparisons show very large deviations concerning hemolysis predictions, depending on the model and model parameter. In light of the current results, two simple power-law models deliver the best compromise between computational efficiency and obtained accuracy. Finally, hemolysis has been computed in an axial blood pump. The reconstructed geometry of a HeartMate II shows that hemolysis occurs mainly at the tip and leading edge of the rotor blades, as well as at the leading edge of the diffusor vanes. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Protection of Clitoria ternatea flower petal extract against free radical-induced hemolysis and oxidative damage in canine erythrocytes.

    PubMed

    Phrueksanan, Wathuwan; Yibchok-anun, Sirinthorn; Adisakwattana, Sirichai

    2014-10-01

    The present study assessed the antioxidant activity and protective ability of Clitoria ternatea flower petal extract (CTE) against in vitro 2,2'-azobis-2-methyl-propanimidamide dihydrochloride (AAPH)-induced hemolysis and oxidative damage of canine erythrocytes. From the phytochemical analysis, CTE contained phenolic compounds, flavonoids, and anthocyanins. In addition, CTE showed antioxidant activity as measured by oxygen radical absorbance capacity (ORAC) method and 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging assay. CTE (400 µg/ml) remarkably protected erythrocytes against AAPH-induced hemolysis at 4 h of incubation. Moreover, CTE (400 µg/ml) reduced membrane lipid peroxidation and protein carbonyl group formation and prevented the reduction of glutathione concentration in AAPH-induced oxidation of erythrocytes. The AAPH-induced morphological alteration of erythrocytes from a smooth discoid to an echinocytic form was effectively protected by CTE. The present results contribute important insights that CTE may have the potential to act as a natural antioxidant to prevent free radical-induced hemolysis, protein oxidation and lipid peroxidation in erythrocytes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. DEMONSTRATION OF INDUCED SYNERGISTIC HEMOLYSIS BY “NONHEMOLYTIC” STAPHYLOCOCCUS SPECIES1

    PubMed Central

    Smith, Doyle C.; Foltz, V. D.; Lord, T. H.

    1964-01-01

    Smith, Doyle C. (Kansas State University, Manhattan), V. D. Foltz, and T. H. Lord. Demonstration of induced synergistic hemolysis by “non-hemolytic” Staphylococcus species. J. Bacteriol. 87:188–195. 1964.—The synergistic hemolysis of “normally nonhemolytic” staphylococci on blood-agar incubated in, or adjacent to, a secondary zone of certain hemolytic staphylococci is described. The synergism apparently results from the combining of two factors, Z, produced by hemolytic staphylococci that elaborate a secondary zone, and T, produced by “nonhemolytic” staphylococci. The production of the two factors is substantiated by (i) the absence of clear hemolysis around nonhemolytic colonies and in the secondary zone of hemolytic colonies, and by (ii) evidence of clear hemolysis when the secondary zone reaches to within a few millimeters, and finally surrounds, the nonhemolytic colonies. It was possible to show on a blood-agar plate containing a mixture of both hemolytic and nonhemolytic cultures that all colonies exhibited a zone of clear hemolysis. When 400 colonies were selected from such a blood plate, 280 were nonhemolytic on subsequent studies. The remaining 120 colonies were hemolytic. Thus, there is danger of confusing non-hemolytic Staphylococcus colonies, showing induced hemolysis, with truly hemolytic colonies. If a similar situation occurred on a diagnostic blood plate, it could very likely result in failure to identify a possibly pathogenic staphylococcus. Images PMID:14102853

  1. Determination of Reynolds Shear Stress Level for Hemolysis.

    PubMed

    Jhun, Choon-Sik; Stauffer, Megan A; Reibson, John D; Yeager, Eric E; Newswanger, Raymond K; Taylor, Joshua O; Manning, Keefe B; Weiss, William J; Rosenberg, Gerson

    Reynolds shear stress (RSS) has served as a metric for the effect of turbulence on hemolysis. Forstrom (1969) and Sallam and Hwang (1984) determined the RSS threshold for hemolysis to be 50,000 and 4,000 dyne/cm, respectively, using a turbulent jet. Despite the order of magnitude discrepancy, the threshold by Sallam and Hwang has been frequently cited for hemolytic potential in blood pumps. We recreated a Sallam apparatus (SA) to resolve this discrepancy and provide additional data to be used in developing a more accurate hemolysis model. Hemolysis was measured over a large range of Reynolds numbers (Re) (Re = 1,000-80,000). Washed bovine red blood cells (RBCs) were injected into the free jet of phosphate buffered saline, and hemolysis was quantified using a percent hemolysis, Hp = h (100 - hematocrit [HCT])/Hb, where h (mg/dl) is free hemoglobin and Hb (mg/dl) is total hemoglobin. Reynolds shear stress was calculated using two-dimensional laser Doppler velocimetry. Reynolds shear stress of ≥30,000 dyne/cm corresponding to Re of ≥60,000 appeared to cause hemolysis (p < 0.05). This RSS is an order of magnitude greater than the RSS threshold that Sallam and Hwang suggested, and it is similar to Forstrom's RSS threshold. This study resolved a long-standing uncertainty regarding the critical values of RSS for hemolysis and may provide a foundation for a more accurate hemolysis model.

  2. Role of hemolysis in red cell adenosine triphosphate release in simulated exercise conditions in vitro.

    PubMed

    Mairbäurl, Heimo; Ruppe, Florian A; Bärtsch, Peter

    2013-10-01

    Specific adenosine triphosphate (ATP) release from red blood cells has been discussed as a possible mediator controlling microcirculation in states of decreased tissue oxygen. Because intravascular hemolysis might also contribute to plasma ATP, we tested in vitro which portion of ATP release is due to hemolysis in typical exercise-induced strains to the red blood cells (shear stress, deoxygenation, and lactic acidosis). Human erythrocytes were suspended in dextran-containing media (hematocrit 10%) and were exposed to shear stress in a rotating Couette viscometer at 37°C. Desaturation (oxygen saturation of hemoglobin ∼20%) was achieved by tonometry with N2 before shear stress exposure. Cells not exposed to shear stress were used as controls. Na lactate (15 mM), lactic acid (15 mM, pH 7.0), and HCl (pH 7.0) were added to simulate exercise-induced lactic acidosis. After incubation, extracellular hemoglobin was measured to quantify hemolysis. ATP was measured with the luciferase assay. Shear stress increased extracellular ATP in a stress-related and time-dependent manner. Hypoxia induced a ∼10-fold increase in extracellular ATP in nonsheared cells and shear stress-exposed cells. Lactic acid had no significant effect on ATP release and hemolysis. In normoxic cells, approximately 20%-50% of extracellular ATP was due to hemolysis. This proportion decreased to less than 10% in hypoxic cells. Our results indicate that when exposing red blood cells to typical strains they encounter when passing through capillaries of exercising skeletal muscle, ATP release from red blood cells is caused mainly by deoxygenation and shear stress, whereas lactic acidosis had only a minor effect. Hemolysis effects were decreased when hemoglobin was deoxygenated. Together, by specific release and hemolysis, extracellular ATP reaches values that have been shown to cause local vasodilatation.

  3. EFFECT OF IONIZING RADIATION OF THE HEMOLYSIS OF ERYTHROCYTES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belousov, A.P.

    1957-05-01

    The saponin hemolysis method is a very effective way of determining the resistance of erythrocytes to radiolysis. The irradiation of rabbits with a dose of 700 r induces the formation of erythrocytes resistant to chemical hemolysis and the rapid disappearance from the blood stream of non-resistant ones. In the case of burns produced by boiling water, blood cell hemolysis is temporarily increased during a period of acute toxicosis. In rabbits irradiated with a dose of 1000 to 1300 r, intensive hemolysis of erythrocytes starts immediately and continues for up to 30 days. The appearance of resistant erythrocytes in the bloodmore » is preceded by a period of active hemopoiesis and the restoration of hemoglobin. Increased resistance of erythrocytes to saponin hemolysis has been observed in rabbits who suffered loss of blood and were subsequently irradiated. Irradiation of the blood in vitro in large doses, as contrasted to small doses, lowers the resistance of erythrocytes to chemical hemolysis. Changes in the resistance of erythrocytes to saponin hemolysis are conditioned by the direct action of radiation on the blood cells and the secondary effect of hemolysins. Thus, knowing the mechanism of the hemolysis of erythrocytes under the influence of ionizing radiation allows a better insight into the pathogenesis of radiation sickness and helps the development of protective means to prevent the onset of hemolysis. (auth)« less

  4. Hemolysis and heat generation in six different types of centrifugal blood pumps.

    PubMed

    Araki, K; Taenaka, Y; Masuzawa, T; Tatsumi, E; Wakisaka, Y; Watari, M; Nakatani, T; Akagi, H; Baba, Y; Anai, H

    1995-09-01

    What the most causative factor affecting hemolysis is still controversial. To resolve this problem, we investigated the relationship between hemolysis and heat generation in six types of centrifugal blood pumps (Bio-Pump, Delphin, Capiox, Nikkiso, Isoflow, and Toyobo). The analyzed parameters were index of hemolysis in fresh goat blood, pumping performance, and heat generation in a thermally isolated mock circuit. These parameters were analyzed at a flow rate of 5 L/min by changing the pressure head (100 mm Hg and 500 mm Hg). At 500 mm Hg of pressure head, the Bio-Pump needed the highest rotation number and showed the highest hemolytic rate and heat generation. The index of hemolysis is well correlated to heat generation (r2 = 0.721). Heat may originate from the motor by conduction, hydraulic energy loss, and mechanical friction between the shaft and seal. We strongly suspect that hemolysis was caused by a factor such as mechanical friction which generates heat locally.

  5. Heat generation and hemolysis at the shaft seal in centrifugal blood pumps.

    PubMed

    Araki, K; Taenaka, Y; Wakisaka, Y; Masuzawa, T; Tatsumi, E; Nakatani, T; Baba, Y; Yagura, A; Eya, K; Toda, K

    1995-01-01

    The heat and hemolysis around a shaft seal were investigated. Materials were original pumps (Nikkiso HMS-15:N-original, and 3M Delphin:D-original), vane-removed pumps (Nvane(-), Dvane(-)), and a small chamber with a shaft coiled by nichrome wire (mock pump). The original pumps were driven at 500 mmHg and 5 L/min, and vane-removed pumps were driven at the same rotation number. An electrical powers of 0, 0.5, 2, and 10 W was supplied to the mock pumps. In vitro hemolytic testing showed that hemolytic indices were 0.027 g/100 L in N-original, 0.013 in Nvane(-), 0.061 in D-original, and 0.012 in Dvane(-). Measurement of heat with a thermally insulated water chamber showed total heat within the pump of 8.62 and 10.85 W, and heat at the shaft seal of 0.87 and 0.62 W in the Nikkiso and Delphin pumps, respectively. Hemolysis and heat generation of mock pumps remained low. The results indicate that the heat generated around the shaft seal was minimal. Hemolysis at the shaft-seal was considerable but not major. Local heat did not affect hemolysis. It was concluded that the shaft-seal affected hemolysis, not by local heat but friction itself.

  6. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.

    PubMed

    Petrova, Darinka Todorova; Cocisiu, Gabriela Ariadna; Eberle, Christoph; Rhode, Karl-Heinz; Brandhorst, Gunnar; Walson, Philip D; Oellerich, Michael

    2013-09-01

    The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb concentrations were estimated from the HI using the Roche Modular automated platform in self-made and commercially available quality controls, as well as samples from a proficiency testing scheme (INSTAND). The fHb using Roche automated HI results were then compared to results obtained using the traditional spectrophotometric assays for one hundred plasma samples with varying degrees of hemolysis, lipemia and/or bilirubinemia. The novel method using automated HI quantification on the Roche Modular clinical chemistry platform correlated well with results using the classical methods in the 100 patient samples (Harboe: r = 0.9284; Fairbanks et al.: r = 0.9689) and recovery was good for self-made controls. However, commercially available quality controls showed poor recovery due to an unidentified matrix problem. The novel method produced reliable determination of fHb in samples without interferences. However, poor recovery using commercially available fHb quality control samples currently greatly limits its usefulness. © 2013.

  7. Investigation of whether the acute hemolysis associated with Rho(D) immune globulin intravenous (human) administration for treatment of immune thrombocytopenic purpura is consistent with the acute hemolytic transfusion reaction model

    PubMed Central

    Gaines, Ann Reed; Lee-Stroka, Hallie; Byrne, Karen; Scott, Dorothy E.; Uhl, Lynne; Lazarus, Ellen; Stroncek, David F.

    2012-01-01

    BACKGROUND Immune thrombocytopenic purpura and secondary thrombocytopenia patients treated with Rho(D) immune globulin intravenous (human; anti-D IGIV) have experienced acute hemolysis, which is inconsistent with the typical presentation of extravascular hemolysis—the presumed mechanism of action of anti-D IGIV. Although the mechanism of anti-D-IGIV–associated acute hemolysis has not been established, the onset, signs/symptoms, and complications appear consistent with the intravascular hemolysis of acute hemolytic transfusion reactions (AHTRs). In transfusion medicine, the red blood cell (RBC) antigen-antibody incompatibility(-ies) that precipitate AHTRs can be detected in vitro with compatibility testing. Under the premise that anti-D-IGIV–associated acute hemolysis results from RBC antigen-antibody–mediated complement activation, this study evaluated whether the incompatibility(-ies) could be detected in vitro with a hemolysin assay, which would support the AHTR model as the hemolytic mechanism. STUDY DESIGN AND METHODS Seven anti-D IGIV lots were tested to determine the RBC antibody identities in those lots, including four lots that had been implicated in acute hemolytic episodes. Hemolysin assays were performed that tested each of 73 RBC specimens against each lot, including the RBCs of one patient who had experienced acute hemolysis after anti-D IGIV administration. RESULTS Only two anti-D IGIV lots contained RBC antibodies beyond those expected. No hemolysis endpoint was observed in any of the hemolysin assays. CONCLUSION Although the findings did not support the AHTR model, the results are reported to contribute knowledge about the mechanism of anti-D-IGIV–associated acute hemolysis and to prompt continued investigation into cause(s), prediction, and prevention of this potentially serious adverse event. PMID:19220820

  8. Disease severity index derived from hemolysis evaluation

    NASA Astrophysics Data System (ADS)

    Piskin, Senol; Finol, Ender A.; Pekkan, Kerem; Vascular Biomechanics; Biofluids Laboratory (VBBL) Team; Pediatric Cardiovascular Fluid Mechanics Laboratory Team

    2017-11-01

    Several cardiovascular diseases (CVDs) are characterized by stenosis of the vessel, leaflet malfunction, disturbance of blood flow (vorticity) due to geometric deformation or abnormal growth, and development of jet flow due to ventricle overload. All of these abnormalities are followed by degeneration of inner wall of the heart and the arteries and red blood cell damage (hemolysis). In this study, identification and classification of CVDs are being performed based on hemolysis evaluation (HE). Two commonly used hemolysis models are implemented to our computational fluid dynamics simulations of CV system. The capability of HE on disease diagnosis is investigated. The analysis will be carried out on our CVD templates such as artery stenosis or pulmonary artery hypertension. HEs depend mainly on the strain rate and for some computational hemolysis models there is a threshold of strain of which the hemolysis will not take place. In the current study, we investigate the effect of thresholding besides using pseudo exposure time for steady state simulations on the blood damage evaluations. Details of our methodology for HE by post processing simulation results without necessity of re-running the simulations will be presented. American Heart Association, National Institute of Health, European Research Council, TUBITAK.

  9. Preanalytic Factors Associated With Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Schold, Jesse D; Hustey, Frederic M; Chamberlin, Janelle; Procop, Gary W

    2018-02-01

    - Hemolysis of emergency department blood samples is a common occurrence and has a negative impact on health care delivery. - To determine the effect of preanalytic factors (straight stick, intravenous [IV] line, needle gauge, location of blood draw, syringe versus vacuum tube use, tourniquet time) on hemolysis in emergency department blood samples. - A single 65 000-visit emergency department's electronic health record was queried for emergency department potassium results and blood draw technique for all samples obtained in calendar year 2014, resulting in 54 531 potassium results. Hemolyzed potassium was measured by hemolysis index. Comparisons of hemolysis by sampling technique were conducted by χ 2 tests. - Overall hemolysis was 10.0% (5439 of 54 531). Hemolysis among samples obtained from straight stick was significantly less than among those obtained with IV line (5.4% [33 of 615] versus 10.2% [4821 of 47 266], P < .001). For IV-placed blood draws, antecubital location had a statistically significant lower overall hemolysis compared with other locations: 7.4% (2117 of 28 786) versus 14.6% (2622 of 17 960) ( P < .001). For blood drawn with a syringe compared with vacuum, hemolysis was 13.0% (92 of 705) and 11.0% (1820 of 16 590), respectively ( P = .09, not significant). For large-gauge IV blood draws versus smaller-gauge IV lines, a lower hemolysis was also observed (9.3% [3882 of 41 571] versus 16.7% [939 of 5633]) ( P < .001). For IV-drawn blood with tourniquet time less than 60 seconds, hemolysis was 10.3% (1362 of 13 162) versus 13.9% for more than 60 seconds (532 of 3832), P < .001. - This study confirmed previous findings that straight stick and antecubital location are significantly associated with reduced hemolysis and indicated that shorter tourniquet time and larger gauge for IV draws were significantly associated with lower hemolysis.

  10. The relationships between air exposure, negative pressure, and hemolysis.

    PubMed

    Pohlmann, Joshua R; Toomasian, John M; Hampton, Claire E; Cook, Keith E; Annich, Gail M; Bartlett, Robert H

    2009-01-01

    The purpose of this study was to describe the hemolytic effects of both negative pressure and an air-blood interface independently and in combination in an in vitro static blood model. Samples of fresh ovine or human blood (5 ml) were subjected to a bubbling air interface (0-100 ml/min) or negative pressure (0-600 mm Hg) separately, or in combination, for controlled periods of time and analyzed for hemolysis. Neither negative pressure nor an air interface alone increased hemolysis. However, when air and negative pressure were combined, hemolysis increased as a function of negative pressure, the air interface, and time. Moreover, when blood samples were exposed to air before initiating the test, hemolysis was four to five times greater than samples not preexposed to air. When these experiments were repeated using freshly drawn human blood, the same phenomena were observed, but the hemolysis was significantly higher than that observed in sheep blood. In this model, hemolysis is caused by combined air and negative pressure and is unrelated to either factor alone.

  11. The Relationships between Air Exposure, Negative Pressure and Hemolysis

    PubMed Central

    Pohlmann, Joshua R.; Toomasian, John M.; Hampton, Claire E.; Cook, Keith E.; Annich, Gail M.; Bartlett, Robert H.

    2013-01-01

    The purpose of this study was to describe the hemolytic effects of both negative pressure and an air-blood interface independently and in combination in an in-vitro static blood model. Samples of fresh ovine or human blood (5 mL) were subjected to a bubbling air interface (0–100 mL/min) or negative pressure (0–600 mmHg) separately, or in combination, for controlled periods of time, and analyzed for hemolysis. Neither negative pressure nor an air interface alone increased hemolysis. However, when air and negative pressure were combined, hemolysis increased as a function of negative pressure, the air interface, and time. Moreover, when blood samples were exposed to air prior to initiating the test, hemolysis was 4–5 times greater than samples not pre-exposed to air. When these experiments were repeated using freshly drawn human blood the same phenomena were observed, but the hemolysis was significantly higher than that observed in sheep blood. In this model, hemolysis is caused by combined air and negative pressure and is unrelated to either factor alone. PMID:19730004

  12. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-09-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  13. Association between alcohol-induced erythrocyte membrane alterations and hemolysis in chronic alcoholics

    PubMed Central

    Bulle, Saradamma; Reddy, Vaddi Damodara; Padmavathi, Pannuru; Maturu, Paramahamsa; Puvvada, Pavan Kumar; Nallanchakravarthula, Varadacharyulu

    2017-01-01

    The present study aimed to understand the association between erythrocyte membrane alterations and hemolysis in chronic alcoholics. Study was conducted on human male volunteers aged between 35–45 years with a drinking history of 8–10 years. Results showed that plasma marker enzymes AST, ALT, ALP and γGT were increased in alcoholic subjects. Plasma and erythrocyte membrane lipid peroxidation, erythrocyte lysate nitric oxide (NOx) levels were also increased significantly in alcoholics. Furthermore, erythrocyte membrane protein carbonyls, total cholesterol, phospholipid and cholesterol/phospholipid (C/P) ratio were increased in alcoholics. SDS-PAGE analysis of erythrocyte membrane proteins revealed that increased density of band 3, protein 4.2, 4.9, actin and glycophorins, whereas glyceraldehyde 3-phosphate dehydrogenase (GAPDH) and glycophorin A showed slight increase, however, decreased ankyrin with no change in spectrins (α and β) and protein 4.1 densities were observed in alcoholics. Moreover, alcoholics red blood cells showed altered morphology with decreased resistance to osmotic hemolysis. Increased hemolysis showed strong positive association with lipid peroxidation (r = 0.703, p<0.05), protein carbonyls (r = 0.754, p<0.05), lysate NOx (r = 0.654, p<0.05) and weak association with C/P ratio (r = 0.240, p<0.05). Bottom line, increased lipid and protein oxidation, altered membrane C/P ratio and membrane cytoskeletal protein profile might be responsible for the increased hemolysis in alcoholics. PMID:28163384

  14. Association between alcohol-induced erythrocyte membrane alterations and hemolysis in chronic alcoholics.

    PubMed

    Bulle, Saradamma; Reddy, Vaddi Damodara; Padmavathi, Pannuru; Maturu, Paramahamsa; Puvvada, Pavan Kumar; Nallanchakravarthula, Varadacharyulu

    2017-01-01

    The present study aimed to understand the association between erythrocyte membrane alterations and hemolysis in chronic alcoholics. Study was conducted on human male volunteers aged between 35-45 years with a drinking history of 8-10 years. Results showed that plasma marker enzymes AST, ALT, ALP and γGT were increased in alcoholic subjects. Plasma and erythrocyte membrane lipid peroxidation, erythrocyte lysate nitric oxide (NOx) levels were also increased significantly in alcoholics. Furthermore, erythrocyte membrane protein carbonyls, total cholesterol, phospholipid and cholesterol/phospholipid (C/P) ratio were increased in alcoholics. SDS-PAGE analysis of erythrocyte membrane proteins revealed that increased density of band 3, protein 4.2, 4.9, actin and glycophorins, whereas glyceraldehyde 3-phosphate dehydrogenase (GAPDH) and glycophorin A showed slight increase, however, decreased ankyrin with no change in spectrins (α and β) and protein 4.1 densities were observed in alcoholics. Moreover, alcoholics red blood cells showed altered morphology with decreased resistance to osmotic hemolysis. Increased hemolysis showed strong positive association with lipid peroxidation ( r  = 0.703, p <0.05), protein carbonyls ( r  = 0.754, p <0.05), lysate NOx ( r  = 0.654, p <0.05) and weak association with C/P ratio ( r  = 0.240, p <0.05). Bottom line, increased lipid and protein oxidation, altered membrane C/P ratio and membrane cytoskeletal protein profile might be responsible for the increased hemolysis in alcoholics.

  15. Haptoglobin Preserves Vascular Nitric Oxide Signaling during Hemolysis.

    PubMed

    Schaer, Christian A; Deuel, Jeremy W; Schildknecht, Daniela; Mahmoudi, Leila; Garcia-Rubio, Ines; Owczarek, Catherine; Schauer, Stefan; Kissner, Reinhard; Banerjee, Uddyalok; Palmer, Andre F; Spahn, Donat R; Irwin, David C; Vallelian, Florence; Buehler, Paul W; Schaer, Dominik J

    2016-05-15

    Hemolysis occurs not only in conditions such as sickle cell disease and malaria but also during transfusion of stored blood, extracorporeal circulation, and sepsis. Cell-free Hb depletes nitric oxide (NO) in the vasculature, causing vasoconstriction and eventually cardiovascular complications. We hypothesize that Hb-binding proteins may preserve vascular NO signaling during hemolysis. Characterization of an archetypical function by which Hb scavenger proteins could preserve NO signaling during hemolysis. We investigated NO reaction kinetics, effects on arterial NO signaling, and tissue distribution of cell-free Hb and its scavenger protein complexes. Extravascular translocation of cell-free Hb into interstitial spaces, including the vascular smooth muscle cell layer of rat and pig coronary arteries, promotes vascular NO resistance. This critical disease process is blocked by haptoglobin. Haptoglobin does not change NO dioxygenation rates of Hb; rather, the large size of the Hb:haptoglobin complex prevents Hb extravasation, which uncouples NO/Hb interaction and vasoconstriction. Size-selective compartmentalization of Hb functions as a substitute for red blood cells after hemolysis and preserves NO signaling in the vasculature. We found that evolutionarily and structurally unrelated Hb-binding proteins, such as PIT54 found in avian species, functionally converged with haptoglobin to protect NO signaling by sequestering cell-free Hb in large protein complexes. Sequential compartmentalization of Hb by erythrocytes and scavenger protein complexes is an archetypical mechanism, which may have supported coevolution of hemolysis and normal vascular function. Therapeutic supplementation of Hb scavengers may restore vascular NO signaling and attenuate disease complications in patients with hemolysis.

  16. Characterization of Storage-Induced Red Blood Cell Hemolysis Using Raman Spectroscopy.

    PubMed

    Gautam, Rekha; Oh, Joo-Yeun; Marques, Marisa B; Dluhy, Richard A; Patel, Rakesh P

    2018-06-11

    The therapeutic efficacy and safety of stored red blood cells (RBCs) relies on minimal in-bag hemolysis. The accuracy of current methods of measuring hemolysis can suffer as a result of specimen collection and processing artefacts. To test whether Raman spectroscopy could be used to assess hemolysis. RBCs were stored for as long as 42 days. Raman spectra of RBCs were measured before and after washing, and hemolysis was measured in supernatant by visible spectroscopy. Raman spectra indicated increased concentrations of oxyhemoglobin (oxyHb) and methemoglobin (metHb), and decreased membrane fluidity with storage age. Changes in oxyHb and metHb were associated with the intraerythrocytic and extracellular fractions, respectively. Hemolysis increased in a storage age-dependent manner. Changes in Raman bands reflective of oxyHb, metHb, and RBC membranes correlated with hemolysis; the most statistically significant change was an increased intensity of metHb and decreased membrane fluidity. These data suggest that Raman spectroscopy may offer a new label-free modality to assess RBC hemolysis during cold storage.

  17. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed Central

    Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.

    2016-01-01

    Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719

  18. Moderate glucose supply reduces hemolysis during systemic inflammation

    PubMed Central

    Jägers, Johannes; Brauckmann, Stephan; Kirsch, Michael; Effenberger-Neidnicht, Katharina

    2018-01-01

    Background Systemic inflammation alters energy metabolism. A sufficient glucose level, however, is most important for erythrocytes, since erythrocytes rely on glucose as sole source of energy. Damage to erythrocytes leads to hemolysis. Both disorders of glucose metabolism and hemolysis are associated with an increased risk of death. The objective of the study was to investigate the impact of intravenous glucose on hemolysis during systemic inflammation. Materials and methods Systemic inflammation was accomplished in male Wistar rats by continuous lipopolysaccharide (LPS) infusion (1 mg LPS/kg and h, 300 min). Sham control group rats received Ringer’s solution. Glucose was supplied moderately (70 mg glucose/kg and h) or excessively (210 mg glucose/kg and h) during systemic inflammation. Vital parameters (eg, systemic blood pressure) as well as blood and plasma parameters (eg, concentrations of glucose, lactate and cell-free hemoglobin, and activity of lactate dehydrogenase) were measured hourly. Clot formation was analyzed by thromboelastometry. Results Continuous infusion of LPS led to a so-called post-aggression syndrome with disturbed electrolyte homeostasis (hypocalcemia, hyperkalemia, and hypernatremia), changes in hemodynamics (tachycardia and hypertension), and a catabolic metabolism (early hyperglycemia, late hypoglycemia, and lactate formation). It induced severe tissue injury (significant increases in plasma concentrations of transaminases and lactate dehydrogenase), alterations in blood coagulation (disturbed clot formation), and massive hemolysis. Both moderate and excessive glucose supply reduced LPS-induced increase in systemic blood pressure. Excessive but not moderate glucose supply increased blood glucose level and enhanced tissue injury. Glucose supply did not reduce LPS-induced alterations in coagulation, but significantly reduced hemolysis induced by LPS. Conclusion Intravenous glucose infusion can diminish LPS-related changes in hemodynamics

  19. Modifications of nano-titania surface for in vitro evaluations of hemolysis, cytotoxicity, and nonspecific protein binding

    NASA Astrophysics Data System (ADS)

    Datta, Aparna; Dasgupta, Sayantan; Mukherjee, Siddhartha

    2017-04-01

    In the past decade, a variety of drug carriers based on mesoporous silica nanoparticles has been extensively reported. However, their biocompatibility still remains debatable, which motivated us to explore the porous nanostructures of other metal oxides, for example titanium dioxide (TiO2), as potential drug delivery vehicles. Herein, we report the in vitro hemolysis, cytotoxicity, and protein binding of TiO2 nanoparticles, synthesized by a sol-gel method. The surface of the TiO2 nanoparticles was modified with hydroxyl, amine, or thiol containing moieties to examine the influence of surface functional groups on the toxicity and protein binding aspects of the nanoparticles. Our study revealed the superior hemocompatibility of pristine, as well as functionalized TiO2 nanoparticles, compared to that of mesoporous silica, the present gold standard. Among the functional groups studied, aminosilane moieties on the TiO2 surface substantially reduced the degree of hemolysis (down to 5%). Further, cytotoxicity studies by MTT assay suggested that surface functional moieties play a crucial role in determining the biocompatibility of the nanoparticles. The presence of NH2- functional groups on the TiO2 nanoparticle surface enhanced the cell viability by almost 28% as compared to its native counterpart (at 100 μg/ml), which was in agreement with the hemolysis assay. Finally, nonspecific protein adsorption on functionalized TiO2 surfaces was examined using human serum albumin and it was found that negatively charged surface moieties, like -OH and -SH, could mitigate protein adsorption to a significant extent.

  20. Hemolysis associated with pneumatic tube system transport for blood samples

    PubMed Central

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830

  1. Hemolysis and cytotoxicity mechanisms of biodegradable magnesium and its alloys.

    PubMed

    Zhen, Zhen; Liu, Xiaoli; Huang, Tao; Xi, TingFei; Zheng, Yufeng

    2015-01-01

    Good hemocompatibility and cell compatibility are essential requirements for coronary stents, especially for biodegradable magnesium alloy stents, which could change the in situ environment after implanted. In this work, the effects of magnesium ion concentration and pH value on the hemolysis and cytotoxicity have been evaluated. Solution with different Mg(2+) concentration gradients and pH values of normal saline and cell culture media DMEM adjusted by MgCl2 and NaOH respectively were tested for the hemolysis and cell viability. Results show that even when the concentration of Mg(2+) reaches 1000 μg/mL, it has little destructive effect on erythrocyte, and the high pH value over 11 caused by the degradation is the real reason for the high hemolysis ratio. Low concentrations of Mg(2+) (<100 μg/mL) cause no cytotoxicity to L929 cells, of which the cell viability is above 80%, while high concentrations of Mg(2+) (>300 μg/mL) could induce obvious death of the L929 cells. The pH of the extract plays a synergetic effect on cytotoxicity, due to the buffer action of the cell culture medium. To validate this conclusion, commercial pure Mg using normal saline and PBS as extract was tested with the measurement of pH and Mg(2+) concentration. Pure Mg leads to a higher hemolysis ratio in normal saline (47.76%) than in buffered solution (4.38%) with different pH values and low concentration of Mg(2+). The Mg extract culture media caused no cytotoxicity, with pH=8.44 and 47.80 μg/mL Mg(2+). It is suggested that buffered solution and dynamic condition should be adopted in the hemolysis evaluation. Copyright © 2014. Published by Elsevier B.V.

  2. Fulminant hemolysis in glucose-6-phosphate dehydrogenase deficiency.

    PubMed

    Moiz, Bushra; Ali, Sidra Asad

    2018-01-01

    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an X-linked disorder affecting some 400 million people worldwide. Though clinically silent, it may result in hemolysis on oxidative stress induced by drugs or infections. Viral hepatitis A with coexisting G6PD deficiency can be devastating associated with severe hemolysis, anemia, renal failure, and hepatic encephalopathy.

  3. Bacillus cereus causing fulminant sepsis and hemolysis in two patients with acute leukemia.

    PubMed

    Arnaout, M K; Tamburro, R F; Bodner, S M; Sandlund, J T; Rivera, G K; Pui, C H; Ribeiro, R C

    1999-01-01

    Hemolysis is so rarely associated with Bacillus cereus sepsis that only two very well documented cases have been reported. This article reports two unusual cases of Bacillus cereus sepsis with massive intravascular hemolysis in patients who had acute lymphoblastic leukemia (ALL). A 20-year-old woman who was 9 weeks pregnant experienced a relapse of ALL. A therapeutic abortion was performed. During week 4 of reinduction the patient had abdominal pain, nausea, and vomiting, with severe neutropenia but no fever. Her condition deteriorated rapidly with cardiovascular collapse, acute massive intravascular hemolysis, and death within hours of the onset of symptoms. Blood cultures were positive for Bacillus cereus. Postmortem histologic examination and cultures revealed Bacillus cereus and Candida albicans in multiple organs. The second patient, a 10-year-old girl, presented with relapsed T-cell ALL. In the second week of reinduction, she had abdominal pain followed by hypotension. Again, no fever was noted. Laboratory studies showed intravascular hemolysis 12 hours after admission. Aggressive support was promptly initiated. Despite disseminated intravascular coagulation; cardiovascular, hepatic, and renal failure; and multiple intracerebral hypodense lesions believed to be infarcts, the patient recovered fully and resumed reinduction therapy. Bacillus cereus infection can have a fulminant clinical course that may be complicated by massive intravascular hemolysis. This pathogen should be suspected in immunosuppressed patients who experience gastrointestinal symptoms and should not be precluded by the absence of fever, especially if steroids such as dexamethasone are being given. Exchange transfusion may be lifesaving in Bacillus cereus septicemia associated with massive hemolysis.

  4. Hemolysis from a nurses' standpoint--survey from four Croatian hospitals.

    PubMed

    Dorotić, Adrijana; Antončić, Dragana; Biljak, Vanja Radišić; Nedić, Dara; Beletić, Andjelo

    2015-01-01

    Hemolysis can occur during sample collection, handling and transport. It is more frequent when the non-laboratory staff performs sampling. The aim of this study was to assess nurses' knowledge on the causes of hemolysis and consequential impact on the laboratory tests results. Additionally, the differences in knowledge, related to work experience, professional degree and previous education about hemolysis were explored. An anonymus survey, containing 11 questions on demographics, causes of hemolysis, its impact on biochemical parameters and nurses' attitude towards additional education in preanalytics, was conducted in four Croatian hospitals. The answers were compared by Chi-squared and Fischer exact test. In total, 562 survey results were collected. Majority of nurses declared familiarity with the term "hemolysis" (99.6%). There were 77% of correct answers regarding questions about the causes of hemolysis, but only 50% when it comes to questions about interference in biochemical tests. The percentage of correct answers about causes was significantly lower (P=0.029) among more experienced nurses, and higher (P=0.027) in those with higher professional degree, while influence of previous education was not significant. Also, higher percentage of correct answers about interferences was encountered in nurses with longer work experience (P=0.039). More than 70% of nurses declared that additional education about preanalytical factors would be beneficial. Croatian nurses are familiar with the definition of hemolysis, but a lack of knowledge about causes and influence on laboratory test results is evident. Nurses are eager to improve their knowledge in this field of preanalytical phase.

  5. PH-dependence of detergent-induced hemolysis and vesiculation of erythrocytes.

    PubMed

    Chernitsky, E A; Rozin, V V; Senkovich, O A

    2001-01-01

    The influence of pH of the medium on the parameters of detergent-induced fast hemolysis and vesiculation of human erythrocytes was studied. In the range of pH 6.3-7.2 neither the extent nor the rate of the vesiculation induced by 25 microM sodium dodecyl sulfate (SDS) changed. However, a decrease of pH from 8.0 to 5.8 strongly modified both the extent and the rate of the hemolysis induced by SDS. Within the range of pH 8.0-6.4, the effect can be ascribed to the increase of the positive charge of the membrane. This could lead to the accumulation of the membrane-bound anion detergent and, hence, to the change of the hemolysis parameters. Non-charged detergent Triton X-100 did not display any pH-dependence. At pH between 6.4 and 5.8 the extent and rate of hemolysis changed in a complicated manner. The kinetic curves of hemolysis could be approximated by a single exponential within the pH range between 8.0 and 7.2. Upon further reduction of pH, a second exponential component, with a larger time constant, appeared in the kinetic curves. At 5.8 < pH < 7.2, the contribution of the "fast" hemolysis dropped virtually to zero, with pK about 6.0. This points to a structural transition of the membrane, possibly involving histidine. We suggest that the parameters of the detergent-induced hemolysis are sensitive to the changes of the charge and structural state of erythrocyte membrane.

  6. Erythrocyte creatine as a marker of intravascular hemolysis due to left ventricular outflow tract obstruction in hypertrophic cardiomyopathy.

    PubMed

    Kubo, Toru; Okumiya, Toshika; Baba, Yuichi; Hirota, Takayoshi; Tanioka, Katsutoshi; Yamasaki, Naohito; Sugiura, Tetsuro; Doi, Yoshinori L; Kitaoka, Hiroaki

    2016-03-01

    Erythrocyte creatine, a marker of erythrocyte age that increases with shortening of erythrocyte survival, has been reported to be a quantitative and reliable marker for intravascular hemolysis. We hypothesized that hemolysis could also occur due to intraventricular obstruction in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to examine the presence of subclinical hemolysis and the relation between intravascular hemolysis and intraventricular pressure gradient (IVPG). We measured erythrocyte creatine in 92 HCM patients. Twelve patients had left ventricular outflow tract obstruction (LVOTO), 4 had midventricular obstruction (MVO), and the remaining 76 were non-obstructive. Erythrocyte creatine levels ranged from 0.92 to 4.36μmol/g hemoglobin. Higher levels of erythrocyte creatine were associated with higher IVPG (r=0.437, p<0.001). If erythrocyte creatine levels are high (≥1.8μmol/g hemoglobin), subclinical hemolysis is considered to be present. Half of LVOTO patients and no MVO patients showed high erythrocyte creatine levels. Although non-obstructive patients did not show significant intraventricular obstruction at rest, some showed high erythrocyte creatine levels. When LVOT-PG was measured during the strain phase of the Valsalva maneuver in 20 non-obstructive patients, 7 of those 20 patients showed LVOTO. In the 20 patients, there was no relation between erythrocyte creatine levels and LVOT-PG before the Valsalva maneuver (r=0.125, p=0.600), whereas there was a significant correlation between erythrocyte creatine and LVOT-PG provoked by the Valsalva maneuver (r=0.695, p=0.001). There is biochemical evidence of subclinical hemolysis in patients with HCM, and this hemolysis seems to be associated with LVOTO provoked by daily physical activities. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  7. Study of Hemolysis During Storage of Blood in the Blood Bank of a Tertiary Health Care Centre.

    PubMed

    Arif, Sayeedul Hasan; Yadav, Neha; Rehman, Suhailur; Mehdi, Ghazala

    2017-12-01

    The aim of RBC storage system in a blood bank is to counteract damage to the metabolic machinery and the membrane, to improve post-transfusion viability. In recent years, the need for strict control over the quality of blood has been emphasised. Such quality indicator includes extend of hemolysis and morphological changes of RBC during storage. This study was design to see extend of hemolysis and level of plasma lactate dehydrogenase (LDH) and plasma potassium, during processing and storage at different intervals under blood bank condition. Forty-six donors were selected and blood units were collected and stored under blood bank conditions. Mean plasma haemoglobin of stored blood was estimated by tetra methyl benzidine method (TMB) and percentage hemolysis was calculated on day 0, 1, 7, 21, 28, 35 and 42 days. Similarly plasma LDH and plasma potassium level was also assessed during storage. It was noted that free haemoglobin level and percentage hemolysis progressively increased with storage along with the level of LDH and potassium. However, extend of hemolysis did not exceed the permissible limit of 0.8% up to 42 days of storage. 15 blood bags which showed visual hemolysis on day 28 did not exceeded the threshold of 0.8% hemolysis, when interpreted by TMB method. It was concluded that TMB method is better than visual method for determination of hemolysis. The reduced hemolysis at this centre may be accounted for the use of additive solution SAGM (Saline, Adenine, Glucose, Mannitol) and DEHP (di-2-ethyl hexyl phthalate) as plasticizer in blood bags for storage.

  8. Expediting red blood cell transfusions by syringing causes significant hemolysis.

    PubMed

    De Villiers, Willem Lambertus; Murray, Adriaan Albertus; Levin, Andrew Ian

    2017-11-01

    Techniques commonly used to expedite blood transfusions include pneumatically pressurizing red blood cell (RBC) bags or manual syringing its contents. We compared these techniques on RBC hemolysis using a simulated transfusion model. Fifteen warmed RBC units that were 12.3 ± 4.3 (95% confidence interval [CI], 10.1-14.5) days old were each subjected to two experimental rapid transfusion techniques. RBCs from each technique were directed through 18- and 22-gauge cannulas attached to blood administration sets. One technique involved RBC bag pressurization to 300 mmHg. The other employed a 20-mL syringe to effect forceful, manual aspiration from the RBC bag followed by forceful, manual RBC injection. The control group was gravity driven without cannulas. Free hemoglobin (Hb) concentrations were measured and percent hemolysis was calculated. Free Hb concentrations and percent hemolysis (median [95% CI]) were similar in the control (0.05 [0.03-0.08] g/dL and 0.13% [0.09%-0.17%], respectively) and pressurized experiments (0.06 [0.05-0.09] g/dL; 0.14% [0.12%-0.22%]), respectively. Syringing resulted in 10-fold higher free Hb concentrations (0.55 [0.38-0.92] g/dL) and percent hemolysis (1.28% [1.03%-2.15%]) than when employing the control (p < 0.0001) or pressurization (p < 0.0001) techniques. Cannula sizes studied did not affect hemolysis. Forceful manual syringing caused significant hemolysis and high free Hb concentrations. Pressurizing RBC bags induced no more hemolysis than after gravity-facilitated transfusions. Syringing to expedite RBC transfusions should be avoided in favor of pneumatic RBC bag pressurization. © 2017 AABB.

  9. Can ginsenosides protect human erythrocytes against free-radical-induced hemolysis?

    PubMed

    Liu, Zai-Qun; Luo, Xu-Yang; Sun, Yun-Xiu; Chen, Yan-Ping; Wang, Zhi-Cai

    2002-08-15

    , and it was found that the order of synergistic antioxidative properties with TOH is Rb1>Rc>Re>Rh1>R1>Rg2>Rb3. Rg3, Rd and Rh2, however, act as synergistic prooxidants in the above experimental system. Rg1 does not show any synergistic antioxidative property. Although the antioxidative and prooxidative mechanism of various ginsenosides with or without TOH in AAPH-induced hemolysis of human erythrocytes will be further studied in detail, this information may be useful in the clinical usage of ginsenosides.

  10. Oxidative Hemolysis of Erythrocytes

    ERIC Educational Resources Information Center

    Wlodek, Lidia; Kusior, Dorota

    2006-01-01

    This exercise for students will allow them to simultaneously observe lipid peroxidation and consequent hemolysis of rat erythrocytes and the effect of sodium azide, a catalase inhibitor, on these processes. It will also demonstrate a protective action of antioxidants, the therapeutically used N-acetylcysteine and albumins present in plasma.

  11. A microplate assay to measure classical and alternative complement activity.

    PubMed

    Puissant-Lubrano, Bénédicte; Fortenfant, Françoise; Winterton, Peter; Blancher, Antoine

    2017-05-01

    We developed and validated a kinetic microplate hemolytic assay (HA) to quantify classical and alternative complement activity in a single dilution of human plasma or serum. The assay is based on monitoring hemolysis of sensitized sheep (or uncoated rabbit) red blood cells by means of a 96-well microplate reader. The activity of the calibrator was evaluated by reference to 200 healthy adults. The conversion of 50% hemolysis time into a percentage of activity was obtained using a calibration curve plotted daily. The linearity of the assay as well as interference (by hemolysis, bilrubinemia and lipemia) was assessed for classical pathway (CP). The within-day and the between-day precision was satisfactory regarding the performance of commercially available liposome immunoassay (LIA) and ELISA. Patients with hereditary or acquired complement deficiencies were detected (activity was measured <30%). We also provided a reference range obtained from 200 blood donors. The agreement of CP evaluated on samples from 48 patients was 94% with LIA and 87.5% with ELISA. The sensitivity of our assay was better than that of LIA, and the cost was lower than either LIA or ELISA. In addition, this assay was less time consuming than previously reported HAs. This assay allows the simultaneous measurement of 36 samples in duplicate per run of a 96-well plate. The use of a daily calibration curve allows standardization of the method and leads to good reproducibility. The same technique was also adapted for the quantification of alternative pathway (AP) activity.

  12. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    PubMed

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Hemolysis in a patient with alkaptonuria and chronic kidney failure.

    PubMed

    Heng, Anne-Elisabeth; Courbebaisse, Marie; Kemeny, Jean Louis; Matesan, Raluca; Bonniol, Claude; Deteix, Patrice; Souweine, Bertrand

    2010-07-01

    In alkaptonuria, the absence of homogentisic acid oxidase results in the accumulation of homogentisic acid (HGA) in the body. Fatal disease cases are infrequent, and death often results from kidney or cardiac complications. We report a 24-year-old alkaptonuric man with severe decreased kidney function who developed fatal metabolic acidosis and intravascular hemolysis. Hemolysis may have been caused by rapid and extensive accumulation of HGA and subsequent accumulation of plasma soluble melanins. Toxic effects of plasma soluble melanins, their intermediates, and reactive oxygen side products are increased when antioxidant mechanisms are overwhelmed. A decrease in serum antioxidative activity has been reported in patients with chronic decreased kidney function. However, despite administration of large doses of an antioxidant agent and ascorbic acid and intensive kidney support, hemolysis and acidosis could not be brought under control and hemolysis led to the death of the patient.

  14. Key factors influencing the incidence of hemolysis: A critical appraisal of current evidence.

    PubMed

    McCaughey, Euan James; Vecellio, Elia; Lake, Rebecca; Li, Ling; Burnett, Leslie; Chesher, Douglas; Braye, Stephen; Mackay, Mark; Gay, Stephanie; Badrick, Tony; Westbrook, Johanna; Georgiou, Andrew

    2017-01-01

    Hemolysis is a leading cause of pre-analytical laboratory errors. The identification of contributing factors is an important step towards the development of effective practices to reduce and prevent hemolysis. We performed a review of PUBMED, Embase, Medline and CINAHL to identify articles published between January 2000 and August 2016 that identified factors influencing in vitro hemolysis rates. The 40 studies included in this review provide excellent evidence that hemolysis rates are higher in Emergency Departments (EDs), for non-antecubital draws, for specimens drawn using an intravenous catheter compared to venipuncture and for samples transported by pneumatic tube compared to by hand. There is also good evidence that hemolysis rates are higher when specimens are not collected by professional phlebotomists, larger volume specimen tubes are used, specimen tubes are filled less than halfway and tourniquet time is greater than one minute. The results of this review suggest that hospitals and clinical laboratories should consider deploying phlebotomists in EDs, drawing all blood through a venipuncture, using the antecubital region as the optimum blood collection site and transporting specimens by laboratory assistant/other personnel, or if this in not practical, ensuring that pneumatic transport systems are validated, maintained and monitored. Studies also recommend making hemolysis a hospital-wide issue and ensuring high-quality staff training and adherence to standard operating procedures to reduce hemolysis rates. Awareness of the factors that influence hemolysis rates, and adoption of strategies to mitigate these risk factors, is an important step towards creating quality practices to reduce hemolysis rates and improve the quality of patient care.

  15. Phenomenon of hot-cold hemolysis: chelator-induced lysis of sphingomyelinase-treated erythrocytes.

    PubMed Central

    Smyth, C J; Möllby, R; Wadström, T

    1975-01-01

    Staphylococcus aureus produces a phospholipase C specific for sphingomyelin (beta-hemolysin). Erythrocytes with approximately 50% sphingomyelin in their membranes, e.g., from sheep, have been shown to have up to 60% of this phospholipid hydrolyzed by this enzyme at 37 C in isotonic buffered saline without hemolysis. Cooling of sphingomyelinase C-treated erythrocytes to 4 C causes complete lysis of the cells, a phenomenon known as hot-cold hemolysis. The addition of ethylenediaminetetraacetate (EDTA) to sheep erythrocytes preincubated with sphingomyelinase C was found to induce rapid hemolysis at 37 C. The treated cells became susceptible to chelator-induced hemolysis and to hot-cold hemolysis simultaneously, and the degree of lysis of both mechanisms increased equally with prolonged preincubation with sphingomyelinase C. Erythrocytes of species not readily susceptible to hot-cold hemolysis were equally insusceptible to chelator-induced lysis. Chelators of the EDTA series were the most effective, whereas chelators more specific for Ca2+, Zn2+, Fe2+, Cu2+, and Mg2+ were without effect. The rate of chelator-induced lysis was dependent on the preincubation period with beta-hemolysin and on the concentration of chelator added. The optimal concentration of EDTA was found to equal the amount of exogenously added Mg2+, a cation necessary for sphingomyelinase C activity. Hypotonicity increased the rate of chelator-induced hemolysis, whereas increasing the osmotic pressure to twice isotonic completely inhibited chelator-induced lysis. The data suggest that exogenously added and/or membrane-bound divalent cations are important for the stability of sphingomyelin-depleted membranes. The phenomenon of hot-cold hemolysis may be a consequence of the temperature dependence of divalent ion stabilization. Images PMID:333

  16. Hemolysis in a laminar flow-through Couette shearing device: an experimental study.

    PubMed

    Boehning, Fiete; Mejia, Tzahiry; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2014-09-01

    Reducing hemolysis has been one of the major goals of rotary blood pump development and in the investigational phase, the capability of hemolysis estimation for areas of elevated shear stresses is valuable. The degree of hemolysis is determined by the amplitude of shear stress and the exposure time, but to date, the exact hemolytic behavior at elevated shear stresses and potential thresholds for subcritical shear exposure remain vague. This study provides experimental hemolysis data for a set of shear stresses and exposure times to allow better estimations of hemolysis for blood exposed to elevated shearing. Heparinized porcine blood with a hematocrit of 40% was mechanically damaged in a flow-through laminar Couette shear flow at a temperature of 23°C. Four levels of shear stress, 24, 592, 702, and 842 Pa, were replicated at two exposure times, 54 and 873 ms. For the calculation of the shear stresses, an apparent viscosity of 5 mPas was used, which was verified in an additional measurement of the blood viscosity. The hemolysis measurements were repeated four times, whereby all conditions were measured once within the same day and with blood from the same source. Samples were taken at the inlet and outlet of the shear region and an increase in plasma-free hemoglobin was measured. An index of hemolysis (IH) was thereby calculated giving the ratio of free to total hemoglobin. The results are compared with data from previously published studies using a similar shearing device. Hemolysis was found to increase exponentially with shear stress, but high standard deviations existed at measurements with elevated IH. At short exposure times, the IH remained low at under 0.5% for all shear stress levels. For high exposure times, the IH increased from 0.84% at 592 Pa up to 3.57% at the highest shear stress level. Hemolysis was significant for shear stresses above ∼600 Pa at the high exposure time of 873 ms. Copyright © 2014 International Center for Artificial

  17. Intravascular hemolysis and the pathophysiology of sickle cell disease

    PubMed Central

    Kato, Gregory J.; Steinberg, Martin H.; Gladwin, Mark T.

    2017-01-01

    Hemolysis is a fundamental feature of sickle cell anemia that contributes to its pathophysiology and phenotypic variability. Decompartmentalized hemoglobin, arginase 1, asymmetric dimethylarginine, and adenine nucleotides are all products of hemolysis that promote vasomotor dysfunction, proliferative vasculopathy, and a multitude of clinical complications of pulmonary and systemic vasculopathy, including pulmonary hypertension, leg ulcers, priapism, chronic kidney disease, and large-artery ischemic stroke. Nitric oxide (NO) is inactivated by cell-free hemoglobin in a dioxygenation reaction that also oxidizes hemoglobin to methemoglobin, a non–oxygen-binding form of hemoglobin that readily loses heme. Circulating hemoglobin and heme represent erythrocytic danger-associated molecular pattern (eDAMP) molecules, which activate the innate immune system and endothelium to an inflammatory, proadhesive state that promotes sickle vaso-occlusion and acute lung injury in murine models of sickle cell disease. Intravascular hemolysis can impair NO bioavailability and cause oxidative stress, altering redox balance and amplifying physiological processes that govern blood flow, hemostasis, inflammation, and angiogenesis. These pathological responses promote regional vasoconstriction and subsequent blood vessel remodeling. Thus, intravascular hemolysis represents an intrinsic mechanism for human vascular disease that manifests clinical complications in sickle cell disease and other chronic hereditary or acquired hemolytic anemias. PMID:28248201

  18. A Serratia marcescens PigP Homolog Controls Prodigiosin Biosynthesis, Swarming Motility and Hemolysis and Is Regulated by cAMP-CRP and HexS

    PubMed Central

    Shanks, Robert M. Q.; Lahr, Roni M.; Stella, Nicholas A.; Arena, Kristin E.; Brothers, Kimberly M.; Kwak, Daniel H.; Liu, Xinyu; Kalivoda, Eric J.

    2013-01-01

    Swarming motility and hemolysis are virulence-associated determinants for a wide array of pathogenic bacteria. The broad host-range opportunistic pathogen Serratia marcescens produces serratamolide, a small cyclic amino-lipid, that promotes swarming motility and hemolysis. Serratamolide is negatively regulated by the transcription factors HexS and CRP. Positive regulators of serratamolide production are unknown. Similar to serratamolide, the antibiotic pigment, prodigiosin, is regulated by temperature, growth phase, HexS, and CRP. Because of this co-regulation, we tested the hypothesis that a homolog of the PigP transcription factor of the atypical Serratia species ATCC 39006, which positively regulates prodigiosin biosynthesis, is also a positive regulator of serratamolide production in S. marcescens. Mutation of pigP in clinical, environmental, and laboratory strains of S. marcescens conferred pleiotropic phenotypes including the loss of swarming motility, hemolysis, and severely reduced prodigiosin and serratamolide synthesis. Transcriptional analysis and electrophoretic mobility shift assays place PigP in a regulatory pathway with upstream regulators CRP and HexS. The data from this study identifies a positive regulator of serratamolide production, describes novel roles for the PigP transcription factor, shows for the first time that PigP directly regulates the pigment biosynthetic operon, and identifies upstream regulators of pigP. This study suggests that PigP is important for the ability of S. marcescens to compete in the environment. PMID:23469212

  19. Effects of hemolysis and lipemia interference on kaolin-activated thromboelastography, and comparison with conventional coagulation tests.

    PubMed

    Tang, Ning; Jin, Xi; Sun, Ziyong; Jian, Cui

    2017-04-01

    The effects of hemolysis and lipemia on thromboelastography (TEG) analysis have been scarcely evaluated in human samples, and neglected in clinical practice. We aimed to investigate the effects of in vitro mechanical hemolysis and lipemia on TEG analysis and conventional coagulation tests. Twenty-four healthy volunteers were enrolled in the study. Besides the controls, three groups with slight, moderate and severe mechanical hemolysis were constituted according to free hemoglobin (Hb) concentrations of 0.5-1.0, 2.0-6.0 and 7.0-13.0 g/L, respectively; and three groups with mild, moderate and high lipemia were established according to triglyceride concentrations of ∼6.0, ∼12.0, and ∼18.0 mmol/L, respectively. Four TEG parameters, reaction time (R), coagulation time (K), angle (α), and maximum amplitude (MA), were measured alongside conventional plasma tests including prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FIB) by mechanical method, and platelet count by optical method. Results showed that the median R and MA values at moderate and severe hemolysis and K at severe hemolysis exceeded respective reference intervals, and were considered unacceptable. Median values of TEG parameters in lipemic samples were all within reference intervals. Bias values of conventional plasma tests PT, APTT and FIB in hemolyzed or lipemic samples were all lower than the Clinical Laboratory Improvement Amendments (CLIA) allowable limits. Bias values of platelet count at moderate to severe hemolysis and lipemia exceeded the CLIA allowable limits. In conclusion, the detection of TEG was in general more affected by mechanical hemolysis than plasma coagulation tests. Pre-analytical variables should be taken into account when unexpected TEG results are obtained.

  20. What is the acceptable hemolysis index for the measurements of plasma potassium, LDH and AST?

    PubMed

    Rousseau, Nathalie; Pige, Raphaëlle; Cohen, Richard; Pecquet, Matthieu

    2016-06-01

    Hemolysis is a cause of variability in test results for plasma potassium, LDH and AST and is a non-negligible part of measurement uncertainty. However, allowable levels of hemolysis provided by reagent suppliers take neither analytical variability (trueness and precision) nor the measurand into account. Using a calibration range of hemolysis, we measured the plasma concentrations of potassium, LDH and AST, and hemolysis indices with a Cobas C501 analyzer (Roche Diagnostics(®), Meylan, France). Based on the allowable total error (according to Ricós et al.) and the expanded measurement uncertainty equation we calculated the maximum allowable bias for two concentrations of each measurand. Finally, we determined the allowable hemolysis indices for all three measurands. We observed a linear relationship between the observed increases of concentration and hemolysis indices. The LDH measurement was the most sensitive to hemolysis, followed by AST and potassium measurements. The determination of the allowable hemolysis index depends on the targeted measurand, its concentration and the chosen level of requirement of allowable total error.

  1. Hemolysis from a nurses’ standpoint – survey from four Croatian hospitals

    PubMed Central

    Dorotić, Adrijana; Antončić, Dragana; Biljak, Vanja Radišić; Nedić, Dara; Beletić, Andjelo

    2015-01-01

    Introduction Hemolysis can occur during sample collection, handling and transport. It is more frequent when the non-laboratory staff performs sampling. The aim of this study was to assess nurses’ knowledge on the causes of hemolysis and consequential impact on the laboratory tests results. Additionally, the differences in knowledge, related to work experience, professional degree and previous education about hemolysis were explored. Materials and methods An anonymus survey, containing 11 questions on demographics, causes of hemolysis, its impact on biochemical parameters and nurses’ attitude towards additional education in preanalytics, was conducted in four Croatian hospitals. The answers were compared by Chi-squared and Fischer exact test. Results In total, 562 survey results were collected. Majority of nurses declared familiarity with the term “hemolysis” (99.6%). There were 77% of correct answers regarding questions about the causes of hemolysis, but only 50% when it comes to questions about interference in biochemical tests. The percentage of correct answers about causes was significantly lower (P = 0.029) among more experienced nurses, and higher (P = 0.027) in those with higher professional degree, while influence of previous education was not significant. Also, higher percentage of correct answers about interferences was encountered in nurses with longer work experience (P = 0.039). More than 70% of nurses declared that additional education about preanalytical factors would be beneficial. Conclusion Croatian nurses are familiar with the definition of hemolysis, but a lack of knowledge about causes and influence on laboratory test results is evident. Nurses are eager to improve their knowledge in this field of preanalytical phase. PMID:26525069

  2. Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters.

    PubMed

    Heiligers-Duckers, Connie; Peters, Nathalie A L R; van Dijck, Jose J P; Hoeijmakers, Jan M J; Janssen, Marcel J W

    2013-08-01

    In-vitro hemolysis is a great challenge to emergency departments where blood is drawn from intravenous catheters (IVCs). Although high quality samples can be obtained by straight needle venipuncture, IVCs are preferred for various reasons. The aim of this study was to identify blood collection practices that reduce hemolysis while using IVC. The study was conducted at an emergency department where blood is drawn in ≥ 90% of patients from IVC. Hemolysis, measured spectrophotometrically, was compared between syringe and vacuum tubes. The following practices were tested in combination with vacuum collection; a Luer-slip adapter, a Luer-lock adapter, discard tubes and low vacuum tubes. Each intervention lasted 1 week and retrieved 154 to 297 samples. As reference, hemolysis was also measured in vacuum tubes retrieved from departments where only straight needle venipuncture is performed. Vacuum collection led to more hemolytic samples compared with syringe tubes (24% versus 16% respectively, p=0.008). No difference in hemolysis was observed between the Luer-slip and the Luer-lock adapter. The use of discard (17% hemolytic, p=0.045) and low vacuum tubes (12% hemolytic, p<0.001) substantially decreased hemolysis. None of the interventions reduced the hemolysis rate to the level observed when drawing blood by straight needle venipuncture (3%, p<0.02). In summary, both discard and low vacuum tubes reduce hemolysis while drawing blood from IVC. Of these practices the use of a low vacuum tube is preferred considering the less volume of blood and the amount of tubes drawn. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Study to determine the clinical significance of HEmolysis During Orbital AtheRectomy (CLEAR study).

    PubMed

    Staniloae, Cezar S; Korabathina, Ravikiran; Lane, Thomas A; Dattilo, Raymond; Church, Kevin J; Mody, Kanika P; Mayeda, Guy S

    2011-02-01

    To evaluate the incidence of clinically evident hemolysis associated with orbital atherectomy used to treat severe peripheral artery disease. The observational CLEAR study enrolled 31 subjects (16 men; mean age 71 ± 10 years, range 44-92) with claudication (58.1%) or critical limb ischemia (38.7%) who underwent orbital atherectomy with the Diamondback 360 system at 4 US centers. The 42 lesions in 31 limbs were located in the superficial femoral (n = 19, 45.2%), popliteal (n = 8, 19.0%), and tibial arteries (n = 15, 35.8%). The majority of lesions (34, 81.0%) were de novo; moderate or severe calcification was identified in 90.5% of cases. Lesion and procedural parameters were analyzed at a core laboratory. Blood samples were collected during and post procedure and analyzed for markers of hemolysis. The primary endpoint was the occurrence of clinically significant hemolysis. The secondary endpoints included the occurrence of any clinical symptoms/signs potentially related to hemolysis. Statistical analysis was performed to identify predictors for hemolysis. Laboratory evidence of hemolysis was seen in 11 (35.5%) subjects. No one met the clinical event criteria, and so the primary endpoint of the study was not reached. The secondary endpoints were hypertensive crisis (1, 3.2%) and transient hemoglobinuria (3, 9.7%). Lower glomerular filtration rates, calcified plaque, long atherectomy runs, and solid crown selection were independent predictors of hemolysis. There was no clinically significant hemolysis after orbital atherectomy. The results of this study will enable users to predict conditions that predispose to high levels of red cell hemolysis following orbital atherectomy and to take appropriate measures to limit its occurrence.

  4. Microbial alcohol-conferred hemolysis is a late response to alcohol stress.

    PubMed

    Shuster, Amir; Korem, Moshe; Jacob-Hirsch, Jasmine; Amariglio, Ninette; Rechavi, Gideon; Rosenberg, Mel

    2011-06-01

    We have reported previously that growth on alcohol vapors confers hemolytic properties on certain yeast species and strains ['microbial alcohol-conferred hemolysis' (MACH)]. In a recent study, we analyzed the genetic basis of MACH in Saccharomyces cerevisiae using the EUROSCARF mutant collection. The data suggested that intact mitochondrial and respiratory chain functions are critical for the observed alcohol-mediated hemolysis. We proposed that the uncontrolled cellular uptake of alcohol results in yeast 'hyper-respiration', leading to elaboration of hemolytic molecules such as hydrogen peroxide and lytic lipids. In the current study, we have further analyzed the molecular mechanisms involved in the MACH phenomenon in S. cerevisiae, using DNA microarrays. The patterns of regulation were confirmed by quantitative reverse transcriptase PCR. The results presented here lend further support to this hypothesis, based on upregulation of the genes responsible for coping with vast amounts of hydrogen peroxide produced as a byproduct of excessive oxidation of alcohol. These results, taken together, show that alcohol-mediated hemolysis in yeast appears to be related to the overproduction of hemolytic byproducts, particularly hydrogen peroxide, which accumulates during long-term exposure of S. cerevisiae to both ethanol and n-butanol. © 2011 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  5. A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests.

    PubMed

    Leme, Juliana; Fonseca, Jeison; Bock, Eduardo; da Silva, Cibele; da Silva, Bruno Utiyama; Dos Santos, Alex Eugênio; Dinkhuysen, Jarbas; Andrade, Aron; Biscegli, José F

    2011-05-01

    A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Testosterone-dependent sex differences in red blood cell hemolysis in storage, stress, and disease.

    PubMed

    Kanias, Tamir; Sinchar, Derek; Osei-Hwedieh, David; Baust, Jeffrey J; Jordan, Andrew; Zimring, James C; Waterman, Hayley R; de Wolski, Karen S; Acker, Jason P; Gladwin, Mark T

    2016-10-01

    Red blood cell (RBC) hemolysis represents an intrinsic mechanism for human vascular disease. Intravascular hemolysis releases hemoglobin and other metabolites that inhibit nitric oxide signaling and drive oxidative and inflammatory stress. Although these pathways are important in disease pathogenesis, genetic and population modifiers of hemolysis, including sex, have not been established. We studied sex differences in storage or stress-induced hemolysis in RBC units from the United States and Canada in 22 inbred mouse strains and in patients with sickle cell disease (SCD) using measures of hemolysis in 315 patients who had homozygous SS hemoglobin from the Walk-PHASST cohort. A mouse model also was used to evaluate posttransfusion recovery of stored RBCs, and gonadectomy was used to determine the mechanisms related to sex hormones. An analysis of predisposition to hemolysis based on sex revealed that male RBCs consistently exhibit increased susceptibility to hemolysis compared with females in response to routine cold storage, under osmotic or oxidative stress, after transfusion in mice, and in patients with SCD. The sex difference is intrinsic to the RBC and is not mediated by plasmatic factors or female sex hormones. Importantly, orchiectomy in mice improves RBC storage stability and posttransfusion recovery, whereas testosterone repletion therapy exacerbates hemolytic response to osmotic or oxidative stress. Our findings suggest that testosterone increases susceptibility to hemolysis across human diseases, suggesting that male sex may modulate clinical outcomes in blood storage and SCD and establishing a role for donor genetic variables in the viability of stored RBCs and in human hemolytic diseases. © 2016 AABB.

  7. Acute intravascular hemolysis and methemoglobinemia following naphthalene ball poisoning.

    PubMed

    Kapoor, Rajan; Suresh, P; Barki, Satish; Mishra, Mayank; Garg, M K

    2014-09-01

    Naphthalene (C10H8) is a natural component of fossil fuels such as petroleum, diesel and coal. The common consumer products made from naphthalene are moth repellents, in the form of mothballs or crystals, and toilet deodorant blocks. Major toxic effects of naphthalene are due to precipitation of acute intravascular hemolysis. Very few cases of naphthalene poisoning and its effects have been reported from India. We report a case of accidental naphthalene poisoning, who presented with intravascular hemolysis and methemoglobinemia.

  8. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    PubMed

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  9. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples

    PubMed Central

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J.

    2010-01-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study. PMID:21197228

  10. Inhibition of free radical-induced erythrocyte hemolysis by 2-O-substituted ascorbic acid derivatives.

    PubMed

    Takebayashi, Jun; Kaji, Hiroaki; Ichiyama, Kenji; Makino, Kazutaka; Gohda, Eiichi; Yamamoto, Itaru; Tai, Akihiro

    2007-10-15

    Inhibitory effects of 2-O-substituted ascorbic acid derivatives, ascorbic acid 2-glucoside (AA-2G), ascorbic acid 2-phosphate (AA-2P), and ascorbic acid 2-sulfate (AA-2S), on 2,2'-azobis(2-amidinopropane) dihydrochloride (AAPH)-induced oxidative hemolysis of sheep erythrocytes were studied and were compared with those of ascorbic acid (AA) and other antioxidants. The order of the inhibition efficiency was AA-2S> or =Trolox=uric acid> or =AA-2P> or =AA-2G=AA>glutathione. Although the reactivity of the AA derivatives against AAPH-derived peroxyl radical (ROO(*)) was much lower than that of AA, the derivatives exerted equal or more potent protective effects on AAPH-induced hemolysis and membrane protein oxidation. In addition, the AA derivatives were found to react per se with ROO(*), not via AA as an intermediate. These findings suggest that secondary reactions between the AA derivative radical and ROO(*) play a part in hemolysis inhibition. Delayed addition of the AA derivatives after AAPH-induced oxidation of erythrocytes had already proceeded showed weaker inhibition of hemolysis compared to that of AA. These results suggest that the AA derivatives per se act as biologically effective antioxidants under moderate oxidative stress and that AA-2G and AA-2P may be able to act under severe oxidative stress after enzymatic conversion to AA in vivo.

  11. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals.

    PubMed

    Milutinović, Dragana; Andrijević, Ilija; Ličina, Milijana; Andrijević, Ljiljana

    2015-01-01

    This study aimed to assess confidence level of healthcare professionals in venipuncture and their knowledge on the possible causes of in vitro hemolysis. A sample of 94 healthcare professionals (nurses and laboratory technicians) participated in this survey study. A four-section questionnaire was used as a research instrument comprising general information for research participants, knowledge on possible causes of in vitro hemolysis due to type of material used and venipuncture technique and specimen handling, as well as assessment of healthcare professionals' confidence level in their own ability to perform first and last venipuncture. The average score on the knowledge test was higher in nurses' than in laboratory technicians (8.11±1.7, and 7.4±1.5, respectively). The difference in average scores was statistically significant (P=0.035) and Cohen's d in the range of 0.4 indicates that there is a moderate difference on the knowledge test among the health care workers. Only 11/94 of healthcare professionals recognized that blood sample collection from cannula and evacuated tube is method which contributes most to the occurrence of in vitro hemolysis, whereas most risk factors affecting occurrence of in vitro hemolysis during venipuncture were recognized. There were no significant differences in mean score on the knowledge test in relation to the confidence level in venipuncture (P=0.551). Confidence level at last venipuncture among both profiles of healthcare staff was very high, but they showed insufficient knowledge about possible factors affecting hemolysis due to materials used in venipuncture compared with factors due to venipuncture technique and handling of blood sample.

  12. Continuous optical measurement system of hemolysis during a photosensitization reaction using absorption spectrum

    NASA Astrophysics Data System (ADS)

    Hamada, R.; Ogawa, E.; Arai, T.

    2018-02-01

    To investigate hemolysis phenomena during a photosensitization reaction with the reaction condition continuously and simultaneously for a safety assessment of hemolysis side effect, we constructed an optical system to measure blood sample absorption spectrum during the reaction. Hemolysis degree might be under estimated in general evaluation methods because there is a constant oxygen pressure assumption in spite of oxygen depression take place. By investigating hemoglobin oxidation and oxygen desorption dynamics obtained from the contribution of the visible absorption spectrum and multiple regression analysis, both the hemolysis phenomena and its oxygen environment might be obtained with time. A 664 nm wavelength laser beam for the reaction excitation and 475-650 nm light beam for measuring the absorbance spectrum were arranged perpendicularly crossing. A quartz glass cuvette with 1×10 mm in dimensions for the spectrum measurement was located at this crossing point. A red blood cells suspension medium was arranged with low hematocrit containing 30 μg/ml talaporfin sodium. This medium was irradiated up to 40 J/cm2 . The met-hemoglobin, oxygenatedhemoglobin, and deoxygenated-hemoglobin concentrations were calculated by a multiple regression analysis from the measured spectra. We confirmed the met-hemoglobin concentration increased and oxygen saturation decreased with the irradiation time, which seems to indicate the hemolysis progression and oxygen consumption, respectively. By using our measuring system, the hemolysis progression seems to be obtained with oxygen environment information.

  13. The role of carboxyhemoglobin measured with CO-oximetry in the detection of hemolysis in newborns with ABO alloimmunization.

    PubMed

    Lozar-Krivec, Jana; Bratanic, Borut; Paro-Panjan, Darja

    2016-01-01

    To evaluate carboxyhemoglobin (COHb) values measured with a CO-oximeter (Roche-cobas b 221) in jaundiced newborns with or without hemolysis and healthy controls in order to assess whether COHb measurement determined with a CO-oximeter could be used as an indicator of hemolysis in newborns with ABO alloimmunization. A total of 86 term newborn infants were prospectively studied. The study cohort consisted of three subgroups: 18 infants with ABO HDN, 21 infants with hyperbilirubinemia without hemolytic disease who required phototherapy, and 47 healthy controls. The COHb, bilirubin, and Hb levels were measured. The three subgroups did not differ significantly with respect to birth weight, gestational age, gender, Apgar score, or mode of delivery. The ABO HDN infants had significantly higher COHb values than the healthy controls (median 2.4% versus 1.3%, p < 0.0005) and the group with hyperbilirubinemia without hemolytic disease (median 2.4% versus 1.3%, p < 0.0005), although the infants with hyperbilirubinemia without hemolytic disease did not have significantly higher COHb values compared with the healthy controls. The cut-off value of 1.7% COHb had 72% sensitivity and 97% specificity for confirming hemolysis in ABO alloimmunization. Our data show that COHb values determined with CO-oximeters are higher in newborns with hemolysis than in those without hemolysis. COHb measured with CO-oximeters could be used to confirm hemolysis in infants with ABO alloimmunization.

  14. Influence of artistic gymnastics on iron nutritional status and exercise-induced hemolysis in female athletes.

    PubMed

    Sureira, Thaiz Mattos; Amancio, Olga Silverio; Pellegrini Braga, Josefina Aparecida

    2012-08-01

    This study evaluates the relationship between body iron losses and gains in artistic gymnastics female athletes. It shows that despite the low iron intake and exercise-induced hemolysis, iron deficiency or iron-deficiency anemia does not occur, but partial changes in the hematological profile do. The hypothesis that gymnasts' nutritional behavior contributes to anemia, which may be aggravated by exercise-induced hemolysis, led to this cross-sectional study, conducted with 43 female artistic gymnasts 6-16 yr old. The control group was formed by 40 nontraining girls, paired by age. Hemogram, serum iron, ferritin, soluble transferrin receptor, haptoglobin, total and fractional bilirubin, Type I urine, and parasitologic and occult fecal blood tests were evaluated. The athletes presented mean hematimetric and serum iron values (p = .020) higher than those of the control group. The bilirubin result discarded any hemolytic alteration in both groups. The haptoglobin results were lower in the athlete group (p = .002), confirming the incidence of exercise-induced hemolysis. Both groups presented low iron intake. The results suggest that artistic gymnastics practice leads to exercise-induced hemolysis and partially changes the hematological profile, although not causing iron deficiency or iron-deficiency anemia, even in the presence of low iron intake.

  15. The protective effects of ginsenosides on human erythrocytes against hemin-induced hemolysis.

    PubMed

    Li, Guo-Xiang; Liu, Zai-Qun

    2008-03-01

    Panax ginseng has been used in traditional Chinese medicine to enhance stamina and capacity to deal with fatigue and physical stress. Many reports have been devoted to the effects of ginsenosides on many in vitro or in vivo experimental systems. The major aim of this work is to investigate the protective effects of 12 individual ginsenosides including Rb1, Rb3, Rc, Rd, Re, Rg1, Rg2, Rg3, Rh1, Rh2, R1 and pseudoginsenoside F11, together with the central structures of aforementioned ginsenosides, 20(S)-protopanaxadiol (PD) and 20(S)-protopanaxatriol (PT), on hemin-induced hemolysis of human erythrocytes. This is because hemin can induce hemolysis by accelerating the potassium leakage, dissociating skeletal proteins and prohibiting some enzymes in the membrane of erythrocyte. Thus, the structure-activity-relationship (SAR) between ginsenosides and protective effects has been screened in this in vitro experimental system. It is found that Rh2 and Rg3 intensify hemolysis in the presence of hemin, and initiate hemolysis even in the absence of hemin. All the other ginsenosides protect human erythrocytes against hemin-induced hemolysis more or less. The overall sequence is Rc>Rd>Re approximately Rb1>Rg1 approximately Rh1>Rb3 approximately Rg2 approximately R1 approximately F11 approximately PT. In addition, the protective effects of PD and PT have been detected, and found that PD promotes hemolysis appreciably, whereas PT protects erythrocytes efficiently. Moreover, the protective effects of PT ginsenosides are similar to PT itself, and the protective effects of PD ginsenosides vary remarkably, demonstrating that the positions of the sugar moieties make the protective activities of ginsenosides complicated. Especially, sugar moiety at 20-position is critical for PD ginsenosides to inhibit hemolysis, whereas hydroxyl group at 3-position is important for PT ginsenosides. The present result may be useful for understanding the SAR of ginsenosides.

  16. [Intravascular Hemolysis Caused by Stenosis of an Elephant Trunk;Report of a Case].

    PubMed

    Takamaru, Rikako; Kawahito, Koji; Aizawa, Kei; Misawa, Yoshio

    2017-07-01

    Symptomatic intravascular hemolysis after prosthetic aortic graft replacement is rare. It is primarily attributed to mechanical injury of red blood cells caused by stenosis of the vascular graft. A 50-year-old man presented with hemolytic anemia, 5 years after total arch replacement with an elephant trunk for type A aortic dissection. The hemolysis was caused by graft stenosis of the elephant trunk. Endovascular treatment for the stenotic elephant trunk was successfully performed. The postoperative course was uneventful, and the hemolysis was resolved immediately after operation.

  17. MULTI-LABORATORY STUDY OF FLOW-INDUCED HEMOLYSIS USING THE FDA BENCHMARK NOZZLE MODEL

    PubMed Central

    Herbertson, Luke H.; Olia, Salim E.; Daly, Amanda; Noatch, Christopher P.; Smith, William A.; Kameneva, Marina V.; Malinauskas, Richard A.

    2015-01-01

    Multilaboratory in vitro blood damage testing was performed on a simple nozzle model to determine how different flow parameters and blood properties affect device-induced hemolysis and to generate data for comparison with computational fluid dynamics-based predictions of blood damage as part of an FDA initiative for assessing medical device safety. Three independent laboratories evaluated hemolysis as a function of nozzle entrance geometry, flow rate, and blood properties. Bovine blood anticoagulated with acid citrate dextrose solution (2–80 h post-draw) was recirculated through nozzle-containing and paired nozzle-free control loops for 2 h. Controlled parameters included hematocrit (36 ± 1.5%), temperature (25°C), blood volume, flow rate, and pressure. Three nozzle test conditions were evaluated (n = 26–36 trials each): (i) sudden contraction at the entrance with a blood flow rate of 5 L/min, (ii) gradual cone at the entrance with a 6-L/min blood flow rate, and (iii) sudden-contraction inlet at 6 L/min. The blood damage caused only by the nozzle model was calculated by subtracting the hemolysis generated by the paired control loop test. Despite high intralaboratory variability, significant differences among the three test conditions were observed, with the sharp nozzle entrance causing the most hemolysis. Modified index of hemolysis (MIHnozzle) values were 0.292 ± 0.249, 0.021 ± 0.128, and 1.239 ± 0.667 for conditions i–iii, respectively. Porcine blood generated hemolysis results similar to those obtained with bovine blood. Although the interlaboratory hemolysis results are only applicable for the specific blood parameters and nozzle model used here, these empirical data may help to advance computational fluid dynamics models for predicting blood damage. PMID:25180887

  18. [Pancytopenia and hemolysis--diagnosis, differential diagnosis and therapy of pernicious anemia].

    PubMed

    Meier, N; Lipp, E; Solenthaler, M

    2007-07-29

    Pernicious anemia and Vitamin B12 deficiency have a wide range of symptoms and are a common finding in the elderly. A 73 year old female is admitted to the hospital because of dyspnea, fatigue and loss of appetite and weight. While previous medical history and physical examination are inconspicuous, laboratory findings show severe pancytopenia with macrocytosis, low reticulocyte count and marked signs of hemolysis. A very low serum level of vitamin B12 and chronic atrophic type A gastritis upon endoscopy with presence of parietal cell antibodies in the serum lead to the diagnosis of pernicious anemia. Complete restitution is achieved by parenteral vitamin B12 substitution. Nowadays, severe pernicious anemia is only rarely seen. The differential diagnosis of pancytopenia (with macrocytic anemia) combined with hemolysis and the essential hints to the diagnosis of pernicious anemia are discussed, and thereby practical aspects including therapy actualized.

  19. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals

    PubMed Central

    Milutinović, Dragana; Andrijević, Ilija; Ličina, Milijana; Andrijević, Ljiljana

    2015-01-01

    Introduction This study aimed to assess confidence level of healthcare professionals in venipuncture and their knowledge on the possible causes of in vitro hemolysis. Materials and methods A sample of 94 healthcare professionals (nurses and laboratory technicians) participated in this survey study. A four-section questionnaire was used as a research instrument comprising general information for research participants, knowledge on possible causes of in vitro hemolysis due to type of material used and venipuncture technique and specimen handling, as well as assessment of healthcare professionals’ confidence level in their own ability to perform first and last venipuncture. Results The average score on the knowledge test was higher in nurses’ than in laboratory technicians (8.11 ± 1.7, and 7.4 ± 1.5, respectively). The difference in average scores was statistically significant (P = 0.035) and Cohen’s d in the range of 0.4 indicates that there is a moderate difference on the knowledge test among the health care workers. Only 11/94 of healthcare professionals recognized that blood sample collection from cannula and evacuated tube is method which contributes most to the occurrence of in vitro hemolysis, whereas most risk factors affecting occurrence of in vitro hemolysis during venipuncture were recognized. There were no significant differences in mean score on the knowledge test in relation to the confidence level in venipuncture (P = 0.551). Conclusion Confidence level at last venipuncture among both profiles of healthcare staff was very high, but they showed insufficient knowledge about possible factors affecting hemolysis due to materials used in venipuncture compared with factors due to venipuncture technique and handling of blood sample. PMID:26527124

  20. On a turbulent wall model to predict hemolysis numerically in medical devices

    NASA Astrophysics Data System (ADS)

    Lee, Seunghun; Chang, Minwook; Kang, Seongwon; Hur, Nahmkeon; Kim, Wonjung

    2017-11-01

    Analyzing degradation of red blood cells is very important for medical devices with blood flows. The blood shear stress has been recognized as the most dominant factor for hemolysis in medical devices. Compared to laminar flows, turbulent flows have higher shear stress values in the regions near the wall. In case of predicting hemolysis numerically, this phenomenon can require a very fine mesh and large computational resources. In order to resolve this issue, the purpose of this study is to develop a turbulent wall model to predict the hemolysis more efficiently. In order to decrease the numerical error of hemolysis prediction in a coarse grid resolution, we divided the computational domain into two regions and applied different approaches to each region. In the near-wall region with a steep velocity gradient, an analytic approach using modeled velocity profile is applied to reduce a numerical error to allow a coarse grid resolution. We adopt the Van Driest law as a model for the mean velocity profile. In a region far from the wall, a regular numerical discretization is applied. The proposed turbulent wall model is evaluated for a few turbulent flows inside a cannula and centrifugal pumps. The results present that the proposed turbulent wall model for hemolysis improves the computational efficiency significantly for engineering applications. Corresponding author.

  1. Improving a Complement-fixation Test for Equine Herpesvirus Type-1 by Pretreating Sera with Potassium Periodate to Reduce Non-specific Hemolysis

    PubMed Central

    BANNAI, Hiroshi; NEMOTO, Manabu; TSUJIMURA, Koji; YAMANAKA, Takashi; KONDO, Takashi; MATSUMURA, Tomio

    2013-01-01

    Non-specific hemolysis has often been observed during complement-fixation (CF) tests for equine herpesvirus type-1 (EHV-1), even when the sera have virus-specific CF antibodies. This phenomenon has also been reported in CF tests for various infectious diseases of swine. We found that the sera from 22 of 85 field horses (25.9%) showed non-specific hemolysis during conventional CF testing for EHV-1. Because pretreatment of swine sera with potassium periodate (KIO4) improves the CF test for swine influenza, we applied this method to horse sera. As we expected, horse sera treated with KIO4 did not show non-specific hemolysis in the EHV-1 CF test, and precise determination of titers was achieved. PMID:24834005

  2. Characterization of core/shell Cu/Ag nanopowders synthesized by electrochemistry and assessment of their impact on hemolysis, platelet aggregation, and coagulation on human blood for potential wound dressing use

    NASA Astrophysics Data System (ADS)

    Laloy, Julie; Haguet, Hélène; Alpan, Lutfiye; Mancier, Valérie; Mejia, Jorge; Levi, Samuel; Dogné, Jean-Michel; Lucas, Stéphane; Rousse, Céline; Fricoteaux, Patrick

    2017-08-01

    Copper/silver core/shell nanopowders with different metal ratio have been elaborated by electrochemistry (ultrasound-assisted electrolysis followed by a displacement reaction). Characterization was performed by several methods (X-ray diffraction, scanning electron microscope, energy-dispersive X-ray spectroscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, centrifugal liquid sedimentation, and zeta potential measurements). The mean diameter of all nanoparticles is around 10 nm. The impact of each nanopowder on hemolysis, platelet aggregation, and coagulation has been studied on whole human blood. Hemolysis assays were performed with spectrophotometric measurement and platelet aggregation, with light transmission aggregometry and was compared to Cu/Pt core/shell nanoparticles with similar size as negative control. Calibrated thrombin generation test has been used for a coagulation study. They neither impact platelet aggregation nor hemolysis and have a procoagulant effect whatever their composition (i.e., metal ratio). These results highlight that such nanopowders have a potential use in medical applications (e.g., wound dressing).

  3. A commercial soy-based phospholipid emulsion accelerates clot formation in normal canine whole blood and induces hemolysis in whole blood from normal and dogs with inflammatory leukograms.

    PubMed

    Behling-Kelly, Erica L; Wakshlag, Joseph

    2018-05-01

    To compare lipid emulsion-induced hemolysis in blood from dogs with inflammatory leukograms to blood from healthy dogs, and determine the impact of a prototypical soy-based phospholipid emulsion on coagulation in whole blood from healthy dogs. Ex vivo study using EDTA and citrated whole blood from healthy dogs and EDTA anticoagulated whole blood from dogs with inflammatory leukograms. University research laboratory. Healthy dogs (total of 16, 9 for hemolysis assays and 6 for thromboelastography) included student- and staff-owned animals. Blood samples from dogs with inflammatory leukograms (8) were obtained from the clinical pathology laboratory after the complete blood count was performed as part of patient care. For the purposes of this study, an inflammatory leukogram was defined as a neutrophilia with a left-shift (minimum of 3% band neutrophils) and evidence of toxic change. None. Hemolysis was measured via spectrophotometric quantification of released hemoglobin and expressed as a percent of a water-lysed control. The soy emulsion caused hemolysis in blood from healthy dogs, ranging from 3.6% to 16.4% as the dose increased, and 4.1% to 25.0% in blood from dogs with inflammatory leukograms. Hemolysis between these patient groups was significantly different at the highest dose. Coagulation was assessed by native thromboelastography. Treatment of whole blood with the lipid emulsion caused a significant decrease in the time to clot formation (R) and a shorter time to reach a clot amplitude of 20 mm (K). Soy-based lipid emulsions cause hemolysis that is more severe in blood from dogs with inflammatory leukograms and accelerate clot formation in canine blood. The in vivo significance of these findings is not clear at this time, but warrants additional investigation given the use of these emulsions in clinical practice. © Veterinary Emergency and Critical Care Society 2018.

  4. Residual Negative Pressure in Vacuum Tubes Might Increase the Risk of Spurious Hemolysis.

    PubMed

    Xiao, Tong-Tong; Zhang, Qiao-Xin; Hu, Jing; Ouyang, Hui-Zhen; Cai, Ying-Mu

    2017-05-01

    We planned a study to establish whether spurious hemolysis may occur when negative pressure remains in vacuum tubes. Four tubes with different vacuum levels (-54, -65, -74, and -86 kPa) were used to examine blood drawn from one healthy volunteer; the tubes were allowed to stand for different times (1, 2, 3, and 4 hours). The plasma was separated and immediately tested for free hemoglobin (FHb). Thirty patients were enrolled in a verification experiment. The degree of hemolysis observed was greater when the remaining negative pressure was higher. Significant differences were recorded in the verification experiment. The results suggest that residual negative pressure might increase the risk of spurious hemolysis.

  5. Impact of Use of Smaller Volume, Smaller Vacuum Blood Collection Tubes on Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Berriochoa, Jacob P; Schold, Jesse D; Hustey, Fredric M; Chamberlin, Janelle; Kovach, Annmarie

    2017-10-01

    Hemolyzed blood samples commonly occur in hospital emergency departments (EDs). Our objective was to determine whether replacing standard large-volume/high-vacuum sample tubes with low-volume/low-vacuum tubes would significantly affect ED hemolysis. This was a prospective intervention of the use of small-volume/vacuum collection tubes. We evaluated all potassium samples in ED patients and associated hemolysis. We used χ2 tests to compare hemolysis incidence prior to and following utilization of small tubes for chemistry collection. There were 35,481 blood samples collected during the study period. Following implementation of small-volume tubes, overall hemolysis decreased from a baseline of 11.8% to 2.9% (P < .001) with corresponding reductions in hemolysis with comment (8.95% vs 1.99%; P < .001) gross hemolysis (2.84% vs 0.90%; P < .007). This work demonstrates that significant improvements in ED hemolysis can be achieved by utilization of small-volume/vacuum sample collection tubes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. Successful use of plasma exchange for profound hemolysis in a child with loxoscelism.

    PubMed

    Said, Ahmed; Hmiel, Paul; Goldsmith, Matthew; Dietzen, Dennis; Hartman, Mary E

    2014-11-01

    We describe a 6-year-old boy who presented with massive hemolysis, shock, disseminated intravascular coagulopathy, and acute renal failure after loxosceles envenomation. In this patient, plasma exchange therapy (PEX) successfully cleared the plasma from an initial hemolytic index of 2000 (equivalent to 2 g/dL hemoglobin, where optimetric laboratory evaluation is impossible) to an index of <50 (no detectable hemolysis). This allowed the PICU team to correct his coagulopathy, assess his degree of organ dysfunction, and provide routine laboratory assessments during continuous venovenous hemodiafiltration. After 9 single volume PEX sessions, his hemolysis and coagulopathy had resolved and his plasma had cleared sufficiently to permit routine laboratory assessments without difficulty. Multiorgan system support with an aggressive transfusion strategy, mechanical ventilation, inotropes, and continuous venovenous hemodiafiltration resulted in complete recovery. We conclude that in the presence of overwhelming hemolysis, plasma can become so icteric that optimetric laboratory evaluation is impossible. In this setting, PEX can be used to clear the plasma, restoring the ability to perform routine laboratory assessments. Copyright © 2014 by the American Academy of Pediatrics.

  7. Relationship between sampling volume of primary serum tubes and spurious hemolysis.

    PubMed

    Lippi, Giuseppe; Musa, Roberta; Battistelli, Luisita; Cervellin, Gianfranco

    2012-01-01

    We planned a study to establish whether spurious hemolysis may be present in low volume tubes or partially filled tubes. Four serum tubes were collected in sequence from 20 healthy volunteers, i.e., 4.0 mL, 13 x 75 mm (discard tube), 6.0 mL, 13 x 100 mm half-filled, 4.0 mL, 13 x 75 mm full-draw and 6.0 mL, 13 x 100 mm full-draw. Serum was separated and immediately tested for hemolysis index (HI), potassium, aspartate aminotransferase (AST), and lactate dehydrogenase (LDH). The HI always remained below the limit of detection of the method (< 0.5 g/L) in all tubes. No statistically significant differences were recorded in any parameter except potassium, which increased by 0.10 mmol/L in 4 mL full-draw tubes. No clinically significant variation was however recorded in any tube. The results suggest that all types of tubes tested might be used interchangeably in term of risk of spurious hemolysis.

  8. Measuring osmosis and hemolysis of red blood cells.

    PubMed

    Goodhead, Lauren K; MacMillan, Frances M

    2017-06-01

    Since the discovery of the composition and structure of the mammalian cell membrane, biologists have had a clearer understanding of how substances enter and exit the cell's interior. The selectively permeable nature of the cell membrane allows the movement of some solutes and prevents the movement of others. This has important consequences for cell volume and the integrity of the cell and, as a result, is of utmost clinical importance, for example in the administration of isotonic intravenous infusions. The concepts of osmolarity and tonicity are often confused by students as impermeant isosmotic solutes such as NaCl are also isotonic; however, isosmotic solutes such as urea are actually hypotonic due to the permeant nature of the membrane. By placing red blood cells in solutions of differing osmolarities and tonicities, this experiment demonstrates the effects of osmosis and the resultant changes in cell volume. Using hemoglobin standard solutions, where known concentrations of hemoglobin are produced, the proportion of hemolysis and the effect of this on resultant hematocrit can be estimated. No change in cell volume occurs in isotonic NaCl, and, by placing blood cells in hypotonic NaCl, incomplete hemolysis occurs. By changing the bathing solution to either distilled water or isosmotic urea, complete hemolysis occurs due to their hypotonic effects. With the use of animal blood in this practical, students gain useful experience in handling tissue fluids and calculating dilutions and can appreciate the science behind clinical scenarios. Copyright © 2017 the American Physiological Society.

  9. Antioxidant activity and protective effect of banana peel against oxidative hemolysis of human erythrocyte at different stages of ripening.

    PubMed

    Sundaram, Shanthy; Anjum, Shadma; Dwivedi, Priyanka; Rai, Gyanendra Kumar

    2011-08-01

    Phytochemicals such as polyphenols and carotenoids are gaining importance because of their contribution to human health and their multiple biological effects such as antioxidant, antimutagenic, anticarcinogenic, and cytoprotective activities and their therapeutic properties. Banana peel is a major by-product in pulp industry and it contains various bioactive compounds like polyphenols, carotenoids, and others. In the present study, effect of ripening, solvent polarity on the content of bioactive compounds of crude banana peel and the protective effect of peel extracts of unripe, ripe, and leaky ripe banana fruit on hydrogen peroxide-induced hemolysis and their antioxidant capacity were investigated. Banana (Musa paradisica) peel at different stages of ripening (unripe, ripe, leaky ripe) were treated with 70% acetone, which were partitioned in order of polarity with water, ethyl acetate, chloroform (CHCl₃), and hexane sequentially. The antioxidant activity of the samples was evaluated by the red cell hemolysis assay, free radical scavenging (1,1-diphenyl-2-picrylhydrazyl free radical elimination) and superoxide dismutase activities. The Folin-Ciocalteu's reagent assay was used to estimate the phenolic content of extracts. The findings of this investigation suggest that the unripe banana peel sample had higher antioxidant potency than ripe and leaky ripe. Further on fractionation, ethyl acetate and water soluble fractions of unripe peel displayed high antioxidant activity than CHCl₃ and hexane fraction, respectively. A positive correlation between free radical scavenging capacity and the content of phenolic compound were found in unripe, ripe, and leaky ripe stages of banana peel.

  10. Senicapoc (ICA-17043): a potential therapy for the prevention and treatment of hemolysis-associated complications in sickle cell anemia.

    PubMed

    Ataga, Kenneth I; Stocker, Jonathan

    2009-02-01

    Sickle cell disease (SCD) is characterized by hemolytic as well as vaso-occlusive complications. The development of treatments for this inherited disease is based on an understanding of its pathophysiology. Polymerization of sickle hemoglobin is dependent on several independent factors, including the intracellular hemoglobin concentration. The hydration state (and intracellular hemoglobin concentration) of the sickle erythrocyte depends on the loss of solute and osmotically obliged water through specific pathways. Senicapoc (also known as ICA-17043) is a potent blocker of the Gardos channel, a calcium-activated potassium channel of intermediate conductance, in the red blood cell. Preclinical studies and studies in transgenic models of SCD show that inhibition of potassium efflux through the Gardos channel is associated with an increased hemoglobin level, decreased dense cells and decreased hemolysis. Senicapoc is well tolerated when administered to SCD patients and produces dose-dependent increases in hemoglobin and decreases in markers of hemolysis. Despite the lack of a reduction in the frequency of pain episodes, the increasing recognition that hemolysis contributes to the development of several SCD-related complications suggests that by decreasing hemolysis, senicapoc may yet prove to be beneficial in this disease.

  11. Evaluation of sample hemolysis in blood collected by S-Monovette using vacuum or aspiration mode.

    PubMed

    Lippi, Giuseppe; Avanzini, Paola; Musa, Roberta; Sandei, Franca; Aloe, Rosalia; Cervellin, Gianfranco

    2013-01-01

    In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the "vacuum" or "aspiration" mode. The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC. In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error. Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.

  12. Clinical usefulness of a functional assay for the von Willebrand factor cleaving protease (ADAMTS 13) and its inhibitor in a patient with thrombotic thrombocytopenic purpura.

    PubMed

    Rick, M E; Austin, H; Leitman, S F; Krizek, D M; Aronson, D L

    2004-02-01

    Decreased von Willebrand factor cleaving protease activity (VWFCP, ADAMTS 13) leads to persistence of unusually large multimers of von Willebrand factor that bind to platelets, causing platelet aggregates, microangiopathic hemolysis, and thrombocytopenia in patients with thrombotic thrombocytopenic purpura (TTP). The clinical value of measuring ADAMTS 13 and its inhibitor is not fully defined; the case reported here illustrates the usefulness of the assay to help confirm the clinical diagnosis in a patient with other potential causes for thrombotic microangiopathy; the assay also helped in making treatment decisions. A patient with systemic lupus erythematosis (SLE) presented with fever and abdominal pain, thrombocytopenia, and anemia. Thrombotic microangiopathy was diagnosed by the appearance of schistocytes, decreasing platelet count, and evidence of hemolysis. ADAMTS 13 was decreased and an inhibitor was demonstrated in the patient's initial blood sample within 24 hr of admission. Plasma exchange was initiated, and serial assays showed increased ADAMTS 13 activity and decreased inhibitor after each plasma exchange; there was a rebound in inhibitor and a decrease in ADAMTS 13 activity prior to the next exchange that lessened over time. Increasing levels of protease activity correlated with clinical and laboratory improvement. Measurement of ADAMTS 13 activity and its inhibitor aided in the diagnosis of this complicated case of a patient with other potential causes for microangiopathic hemolysis. Subsequent levels correlated with the clinical course, and disappearance of the inhibitor indicated that long-term plasma exchange or other immunosuppressive treatment was not needed.

  13. Nanoformulated water-soluble paclitaxel to enhance drug efficacy and reduce hemolysis side effect.

    PubMed

    Gu, Weiting; Chen, Jie; Patra, Prabir; Yang, Xiaoyan; Gu, Quanrong; Wei, Lingxuan; Acker, Jason P; Kong, Beihua

    2017-07-01

    Surgery, chemotherapy, and radiotherapy are the three top cancer treatment modalities. Paclitaxel (PTX) is one of the most widely used chemotherapy drugs. However, its clinical applications have been significantly limited due to: (i) serious hemolysis effect of currently available commercial paclitaxel formulations and (ii) its water insolubility. An easy way to deliver paclitaxel by a new nanocarrier system using pluronic copolymers of P123/F68 and Sorbitan monopalmitate (Span 40) was reported in our previous research article. The characterization of the formulation and analysis of drug release and cellular uptake were also presented. In this article, we reported discoveries of our follow-up in vivo antitumor and in vitro hemolytic study discoveries. The experimental results showed that the nanoformulated PTX achieved much better tumor suppression performance while reducing hemolysis side effects. This newly formulated drug can significantly improve patient outcomes in cancer chemotherapy.

  14. Medicinal activities of the leaves of Musa sapientum var. sylvesteris in vitro

    PubMed Central

    Sahaa, Repon Kumer; Acharyaa, Srijan; Shovon, Syed Sohidul Haque; Royb, Priyanka

    2013-01-01

    Objective This study is to investigate the medicinal value of methanolic extract of the leaves of Musa sapientum var. sylvesteris in Bangladesh. Methods Several biochemical assays, thin layer chormatogarphy and ultra-violet spectroscopy were used to detect the presence of various types of compounds in this extract. Antioxidant effects were measured by DPPH scavenging assay, total reducing assay and hydrogen peroxide scavenging assay. Receptor binding activities and hydrogen peroxide induced hemolysis assay were performed by hemagglutination assay and hemolysis assay using erythrocytes. Disk diffusion assay was performed to show the antibacterial effect of the extract. Results Methanolic extract of the leaves showed antioxidant and antibacterial activity in vitro. The extract showed hemaglutination inhibition activities and hydrogen peroxide induced hemolysis inhibition activity of human red blood cells. Conclusion Musa sapientum var. sylvesteris can be an useful medicinal plant. PMID:23730561

  15. Computational prediction of hemolysis in a centrifugal ventricular assist device.

    PubMed

    Pinotti, M; Rosa, E S

    1995-03-01

    This paper describes the use of computational fluid dynamics (CFD) to predict numerically the hemolysis in centrifugal pumps. A numerical hydrodynamical model, based on the full Navier-Stokes equation, was used to obtain the flow in a vaneless centrifugal pump (of corotating disks type). After proper postprocessing, critical zones in the channel were identified by means of two-dimensional color-coded maps of %Hb release. Simulation of different conditions revealed that flow behavior at the entrance region of the channel is the main cause of blood trauma in such devices. A useful feature resulting from the CFD simulation is the visualization of critical flow zones that are impossible to determine experimentally with in vitro hemolysis tests.

  16. Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO - Prevalence and Risk Factors.

    PubMed

    Lehle, Karla; Philipp, Alois; Zeman, Florian; Lunz, Dirk; Lubnow, Matthias; Wendel, Hans-Peter; Göbölös, Laszlo; Schmid, Christof; Müller, Thomas

    2015-01-01

    The aim of the study was to explore the prevalence and risk factors for technical-induced hemolysis in adults supported with veno-venous extracorporeal membrane oxygenation (vvECMO) and to analyze the effect of hemolytic episodes on outcome. This was a retrospective, single-center study that included 318 adult patients (Regensburg ECMO Registry, 2009-2014) with acute respiratory failure treated with different modern miniaturized ECMO systems. Free plasma hemoglobin (fHb) was used as indicator for hemolysis. Throughout a cumulative support duration of 4,142 days on ECMO only 1.7% of the fHb levels were above a critical value of 500 mg/l. A grave rise in fHb indicated pumphead thrombosis (n = 8), while acute oxygenator thrombosis (n = 15) did not affect fHb. Replacement of the pumphead normalized fHb within two days. Neither pump or cannula type nor duration on the first system was associated with hemolysis. Multiple trauma, need for kidney replacement therapy, increased daily red blood cell transfusion requirements, and high blood flow (3.0-4.5 L/min) through small-sized cannulas significantly resulted in augmented blood cell trauma. Survivors were characterized by lower peak levels of fHb [90 (60, 142) mg/l] in comparison to non-survivors [148 (91, 256) mg/l, p≤0.001]. In conclusion, marked hemolysis is not common in vvECMO with modern devices. Clinically obvious hemolysis often is caused by pumphead thrombosis. High flow velocity through small cannulas may also cause technical-induced hemolysis. In patients who developed lung failure due to trauma, fHb was elevated independantly of ECMO. In our cohort, the occurance of hemolysis was associated with increased mortality.

  17. Hemolysis-induced lethality involves inflammasome activation by heme.

    PubMed

    Dutra, Fabianno F; Alves, Letícia S; Rodrigues, Danielle; Fernandez, Patricia L; de Oliveira, Rosane B; Golenbock, Douglas T; Zamboni, Dario S; Bozza, Marcelo T

    2014-09-30

    The increase of extracellular heme is a hallmark of hemolysis or extensive cell damage. Heme has prooxidant, cytotoxic, and inflammatory effects, playing a central role in the pathogenesis of malaria, sepsis, and sickle cell disease. However, the mechanisms by which heme is sensed by innate immune cells contributing to these diseases are not fully characterized. We found that heme, but not porphyrins without iron, activated LPS-primed macrophages promoting the processing of IL-1β dependent on nucleotide-binding domain and leucine rich repeat containing family, pyrin domain containing 3 (NLRP3). The activation of NLRP3 by heme required spleen tyrosine kinase, NADPH oxidase-2, mitochondrial reactive oxygen species, and K(+) efflux, whereas it was independent of heme internalization, lysosomal damage, ATP release, the purinergic receptor P2X7, and cell death. Importantly, our results indicated the participation of macrophages, NLRP3 inflammasome components, and IL-1R in the lethality caused by sterile hemolysis. Thus, understanding the molecular pathways affected by heme in innate immune cells might prove useful to identify new therapeutic targets for diseases that have heme release.

  18. Using Lean-Six Sigma to reduce hemolysis in the emergency care center in a collaborative quality improvement project with the hospital laboratory.

    PubMed

    Damato, Charlotte; Rickard, Dana

    2015-03-01

    As part of a strategic quality improvement plan, laboratory management at Sarasota Memorial Health Care System (SMHCS) focused its efforts on improving preanalytical work flow and blood collection processes-both negatively affected by hemolyzed specimens. When hemolysis is detected in a blood specimen, blood may need to be re-collected, resulting in bottlenecks and rework all along the value stream. From July through December 2009, hemolysis averaged 9.8% in the Emergency Care Center (ECC) and 3.4% housewide. The goal was set to reduce hemolysis to 2%. The project team identified hemolysis as one of seven factors contributing to non-value-added activities and bottlenecks in blood collection and preanalytical processes. Observations and interviews helped to identify error-prone practices and process variation. To verify the root causes of hemolysis, the findings were compared against best practices. The team developed a housewide protocol, standardized collection processes, created competency-based training, and enhanced ECC hiring practices. During December 2010-March 2011, following initial housewide interventions and ECC self-sustaining solutions, ECC hemolysis decreased by 91%-from 9.8% (423 hemolyzed/4,295 collected) to 0.88% (58 hemolyzed/6,560 collected). Housewide hemolysis decreased by 59%-from 3.4% (2,046 hemolyzed/60,307 collected) to 1.39% (619 hemolyzed/44,528 collected). Since the project, hemolysis has continued to trend downward; the mean percentage has consistently been < .05% for the ECC and < 1% housewide. Lean-Six Sigma tools helped to pinpoint hemolysis as a key inefficiency in blood collection and preanalytical work flow. Although focused on the ECC, the project team standardized blood collection practices and instituted quality devices to achieve hemolysis reductions housewide.

  19. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.

    PubMed

    Birschmann, Ingvild; Dittrich, Marcus; Eller, Thomas; Wiegmann, Bettina; Reininger, Armin J; Budde, Ulrich; Strüber, Martin

    2014-01-01

    Thromboembolic and bleeding events in patients with a left ventricular assist device (LVAD) are still a major cause of complications. Therefore, the balance between anti-coagulant and pro-coagulant factors needs to be tightly controlled. The principle hypothesis of this study is that different pump designs may have an effect on hemolysis and activation of the coagulation system. Referring to this, the HeartMate II (HMII; Thoratec Corp, Pleasanton, CA) and the HeartWare HVAD (HeartWare International Inc, Framingham, MA) were investigated. For 20 patients with LVAD support (n = 10 each), plasma coagulation, full blood count, and clinical chemistry parameters were measured. Platelet function was monitored using platelet aggregometry, platelet function analyzer-100 system ( Siemens, Marburg, Germany), vasodilator-stimulated phosphoprotein phosphorylation assay, immature platelet fraction, platelet-derived microparticles, and von Willebrand diagnostic. Acquired von Willebrand syndrome could be detected in all patients. Signs of hemolysis, as measured by lactate dehydrogenase levels (mean, 470 U/liter HMII, 250 U/liter HVAD; p < 0.001), were more pronounced in the HMII patients. In contrast, D-dimer analysis indicated a significantly higher activation of the coagulation system in HVAD patients (mean, 0.94 mg/liter HMII, 2.01 mg/liter HVAD; p < 0.01). The efficacy of anti-platelet therapy using clopidogrel was not sufficient in more than 50% of the patients. Our results support the finding that all patients with rotary blood pumps suffered from von Willebrand syndrome. In addition, a distinct footprint of effects on hemolysis and the coagulation system can be attributed to different devices. As a consequence, the individual status of the coagulation system needs to be controlled in long-term patients. © 2013 Published by International Society for the Heart and Lung Transplantation on behalf of International Society for Heart and Lung Transplantation.

  20. Development of screening assays for nanoparticle toxicity assessment in human blood: preliminary studies with charged Au nanoparticles.

    PubMed

    Love, Sara A; Thompson, John W; Haynes, Christy L

    2012-09-01

    As nanoparticles have found increased use in both consumer and medical applications, corresponding increases in possible exposure to humans necessitate studies examining the impacts of these nanomaterials in biological systems. This article examines the effects of approximately 30-nm-diameter gold nanoparticles, with positively and negatively charged surface coatings in human blood. Here, we study the exposure effects, with up to 72 h of exposure to 5, 15, 25 and 50 µg/ml nanoparticles on hemolysis, reactive oxygen species (ROS) generation and platelet aggregation in subsets of cells from human blood. Assessing viability with hemolysis, results show significant changes in a concentration-dependent fashion. Rates of ROS generation were investigated using the dichlorofluorscein diacetate-based assay as ROS generation is a commonly suspected mechanism of nanoparticle toxicity; herein, ROS was not a significant factor. Optical monitoring of platelet aggregation revealed that none of the examined nanoparticles induced aggregation upon short-term exposure.

  1. Poor knowledge and faulty thinking regarding hemolysis and potassium elevation.

    PubMed

    Hawkins, Robert C

    2005-01-01

    A questionnaire to assess knowledge of the expected elevation in serum K measurement with different grades of hemolysis was administered to medical technologists working in biochemistry laboratories, hospital physicians and nurses. The questions involved different grades of hemolysis (mild, 1.0, moderate, 2.5 and severe, 5.0 g/L) and different final K measurements (2.9, 4.0, 5.2 and 8.2 mmol/L). Subjects estimated the K concentration in a non-hemolyzed sample for each scenario. Adjustment values (difference between final hemolyzed K concentration and subject's response) were calculated. For the 132 respondees, the mean correct score was 1.7/12. Mean adjustment values were: mild, 0.43 mmol/L (K 2.9), 0.55 (4.0), 0.88 (5.2) and 1.53 (8.2); moderate, 0.85 (2.9), 0.92 (4.0), 1.33 (5.2) and 2.50 (8.2); and severe, 0.93 (2.9), 1.48 (4.0), 1.96 (5.2), 2.96 (8.2). Correct adjustments were: mild, 0.28; moderate, 0.70; and severe, 1.40 mmol/L. Healthcare staff overestimated the effect of hemolysis on potassium measurement and used an incorrect proportional adjustment approach to the problem. Such poor knowledge and faulty thinking could lead to diagnostic delays or misdiagnoses. There is potential for such faulty thinking in all areas of laboratory medicine, and laboratories should review their educational responsibilities and reporting practices in light of this.

  2. Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO – Prevalence and Risk Factors

    PubMed Central

    Lehle, Karla; Philipp, Alois; Zeman, Florian; Lunz, Dirk; Lubnow, Matthias; Wendel, Hans-Peter; Göbölös, Laszlo; Schmid, Christof; Müller, Thomas

    2015-01-01

    The aim of the study was to explore the prevalence and risk factors for technical-induced hemolysis in adults supported with veno-venous extracorporeal membrane oxygenation (vvECMO) and to analyze the effect of hemolytic episodes on outcome. This was a retrospective, single-center study that included 318 adult patients (Regensburg ECMO Registry, 2009–2014) with acute respiratory failure treated with different modern miniaturized ECMO systems. Free plasma hemoglobin (fHb) was used as indicator for hemolysis. Throughout a cumulative support duration of 4,142 days on ECMO only 1.7% of the fHb levels were above a critical value of 500 mg/l. A grave rise in fHb indicated pumphead thrombosis (n = 8), while acute oxygenator thrombosis (n = 15) did not affect fHb. Replacement of the pumphead normalized fHb within two days. Neither pump or cannula type nor duration on the first system was associated with hemolysis. Multiple trauma, need for kidney replacement therapy, increased daily red blood cell transfusion requirements, and high blood flow (3.0–4.5 L/min) through small-sized cannulas significantly resulted in augmented blood cell trauma. Survivors were characterized by lower peak levels of fHb [90 (60, 142) mg/l] in comparison to non-survivors [148 (91, 256) mg/l, p≤0.001]. In conclusion, marked hemolysis is not common in vvECMO with modern devices. Clinically obvious hemolysis often is caused by pumphead thrombosis. High flow velocity through small cannulas may also cause technical-induced hemolysis. In patients who developed lung failure due to trauma, fHb was elevated independantly of ECMO. In our cohort, the occurance of hemolysis was associated with increased mortality. PMID:26606144

  3. Trpc2 Depletion Protects RBC from Oxidative Stress-Induced Hemolysis

    PubMed Central

    Hirschler-Laszkiewicz, Iwona; Zhang, Wenyi; Keefer, Kerry; Conrad, Kathleen; Tong, Qin; Chen, Shu-jen; Bronson, Sarah; Cheung, Joseph Y.; Miller, Barbara A.

    2011-01-01

    Transient receptor potential channels Trpc2 and Trpc3 are expressed on normal murine erythroid precursors, and erythropoietin stimulates an increase in intracellular calcium ([Ca2+]i) through TRPC2 and TRPC3. Because modulation of [Ca2+]i is an important signaling pathway in erythroid proliferation and differentiation, Trpc2, Trpc3, and Trpc2/Trpc3 double knockout mice were utilized to explore the roles of these channels in erythropoiesis. Trpc2, Trpc3, and Trpc2/Trpc3 double knockout mice were not anemic, and had similar red blood cell counts, hemoglobins, and reticulocyte counts as wild type littermate controls. Although the erythropoietin induced increase in [Ca2+]i was reduced, these knockout mice showed no defects in red cell production. The major phenotypic difference at steady state was that the mean corpuscular volume, mean corpuscular hemoglobin, and hematocrit of red cells were significantly greater in Trpc2 and Trpc2/Trpc3 double knockout mice, and mean corpuscular hemoglobin concentration was significantly reduced. All hematological parameters in Trpc3 knockout mice were similar to controls. When exposed to phenyhydrazine, unlike the Trpc3 knockouts, Trpc2 and Trpc2/Trpc3 double knockout mice showed significant resistance to hemolysis. This was associated with significant reduction in hydrogen peroxide-induced calcium influx in erythroblasts. While erythropoietin induced calcium influx through TRPC2 or TRPC3 is not critical for erythroid production, these data demonstrate that TRPC2 plays an important role in oxidative stress-induced hemolysis which may be related to reduced calcium entry in red cells in the presence of Trpc2 depletion. PMID:21924222

  4. Hemolysis-induced lethality involves inflammasome activation by heme

    PubMed Central

    Dutra, Fabianno F.; Alves, Letícia S.; Rodrigues, Danielle; Fernandez, Patricia L.; de Oliveira, Rosane B.; Golenbock, Douglas T.; Zamboni, Dario S.; Bozza, Marcelo T.

    2014-01-01

    The increase of extracellular heme is a hallmark of hemolysis or extensive cell damage. Heme has prooxidant, cytotoxic, and inflammatory effects, playing a central role in the pathogenesis of malaria, sepsis, and sickle cell disease. However, the mechanisms by which heme is sensed by innate immune cells contributing to these diseases are not fully characterized. We found that heme, but not porphyrins without iron, activated LPS-primed macrophages promoting the processing of IL-1β dependent on nucleotide-binding domain and leucine rich repeat containing family, pyrin domain containing 3 (NLRP3). The activation of NLRP3 by heme required spleen tyrosine kinase, NADPH oxidase-2, mitochondrial reactive oxygen species, and K+ efflux, whereas it was independent of heme internalization, lysosomal damage, ATP release, the purinergic receptor P2X7, and cell death. Importantly, our results indicated the participation of macrophages, NLRP3 inflammasome components, and IL-1R in the lethality caused by sterile hemolysis. Thus, understanding the molecular pathways affected by heme in innate immune cells might prove useful to identify new therapeutic targets for diseases that have heme release. PMID:25225402

  5. [The Relevance of Hemolysis in Anesthesia and Intensive Care Medicine].

    PubMed

    Graw, Jan A; Baron, David M; Francis, Roland C E

    2018-04-01

    Hemolysis leads to an increase of circulating intravascular cell-free hemoglobin. Increased plasma concentrations of cell-free hemoglobin are relevant in critically ill patients because cell-free hemoglobin causes vasoconstriction by depletion of endothelial nitric oxide, oxidative stress, and inflammation. Furthermore, cell-free hemoglobin contributes to tissue injuries such as renal failure and intestinal mucosa damage after cardiac surgery. High concentrations of cell-free hemoglobin are associated with an increased mortality in patients with sepsis. Currently, it is unclear if hemolysis associated with transfusion of packed red blood cells that have been stored for prolonged periods of time is relevant for the clinical outcome. However, humans possess plasma proteins haptoglobin and hemopexin which bind to plasma hemoglobin and cell-free heme, respectively. The haptoglobin-hemoglobin and hemopexin-heme complexes are then eliminated from the plasma by hepatic or splenic uptake. Georg Thieme Verlag KG Stuttgart · New York.

  6. Evaluation of a Spiral Groove Geometry for Improvement of Hemolysis Level in a Hydrodynamically Levitated Centrifugal Blood Pump.

    PubMed

    Murashige, Tomotaka; Kosaka, Ryo; Sakota, Daisuke; Nishida, Masahiro; Kawaguchi, Yasuo; Yamane, Takashi; Maruyama, Osamu

    2015-08-01

    The purpose of this study is to evaluate a spiral groove geometry for a thrust bearing to improve the hemolysis level in a hydrodynamically levitated centrifugal blood pump. We compared three geometric models: (i) the groove width is the same as the ridge width at any given polar coordinate (conventional model); (ii) the groove width contracts inward from 9.7 to 0.5 mm (contraction model); and (iii) the groove width expands inward from 0.5 to 4.2 mm (expansion model). To evaluate the hemolysis level, an impeller levitation performance test and in vitro hemolysis test were conducted using a mock circulation loop. In these tests, the driving conditions were set at a pressure head of 200 mm Hg and a flow rate of 4.0 L/min. As a result of the impeller levitation performance test, the bottom bearing gaps of the contraction and conventional models were 88 and 25 μm, respectively. The impeller of the expansion model touched the bottom housing. In the hemolysis test, the relative normalized index of hemolysis (NIH) ratios of the contraction model in comparison with BPX-80 and HPM-15 were 0.6 and 0.9, respectively. In contrast, the relative NIH ratios of the conventional model in comparison with BPX-80 and HPM-15 were 9.6 and 13.7, respectively. We confirmed that the contraction model achieved a large bearing gap and improved the hemolysis level in a hydrodynamically levitated centrifugal blood pump. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Morphological Effects and Antioxidant Capacity of Solanum crispum (Natre) In Vitro Assayed on Human Erythrocytes.

    PubMed

    Suwalsky, Mario; Ramírez, Patricia; Avello, Marcia; Villena, Fernando; Gallardo, María José; Barriga, Andrés; Manrique-Moreno, Marcela

    2016-06-01

    In order to gain insight into the molecular mechanism of the antioxidant properties of Solanum crispum, aqueous extracts of its leaves were assayed on human erythrocytes and molecular models of its membrane. Phenolics and alkaloids were detected by HPLC-MS. Scanning electron and defocusing microscopy showed that S. crispum changed erythrocytes from the normal shape to echinocytes. These results imply that molecules present in the aqueous extracts were located in the outer monolayer of the erythrocyte membrane. Dimyristoylphosphatidylcholine (DMPC) and dimyristoylphosphatidylethanolamine (DMPE) were chosen as representative of phospholipid classes located in the outer and inner monolayers of the erythrocyte membrane, respectively. X-ray diffraction showed that S. crispum preferentially interacted with DMPC bilayers. Experiments regarding its antioxidant properties showed that S. crispum neutralized the oxidative capacity of HClO on DMPE bilayers; defocusing microscopy and hemolysis assays demonstrated the protective effect of S. crispum against the oxidant effects of HClO on human erythrocytes.

  8. A mobile phone-based approach to detection of hemolysis.

    PubMed

    Archibong, Edikan; Konnaiyan, Karthik Raj; Kaplan, Howard; Pyayt, Anna

    2017-02-15

    Preeclampsia and HELLP (hemolysis, elevated liver enzymes, and low platelet count) syndrome are pregnancy-related complications with high rates of morbidity and mortality. HELLP syndrome, in particular, can be difficult to diagnose. Recent work suggests that elevated levels of free cell hemoglobin in blood plasma can, as early as the first trimester, potentially serve as a diagnostic biomarker for impending complications. We therefore developed a point-of-care mobile phone-based platform that can quickly characterize a patient's level of hemolysis by measuring the color of blood plasma. The custom hardware and software are designed to be easy to use. A sample of the whole blood (~10µL or less) is first collected into a clear capillary tube or microtube, which is then inserted into a low-cost 3D-printed sample holder attached to the phone. A 5-10min period of quiescence allows for gravitational sedimentation of the red blood cells, leaving a layer of yellowish plasma at the top of the tube. The phone camera then photographs the capillary tube and analyzes the color components of the cell-free plasma layer. The software converts these color values to a concentration of free hemoglobin, based on a built-in calibration curve, and reports the patient's hemolysis level: non-hemolyzed, slightly hemolyzed, mildly hemolyzed, frankly hemolyzed, or grossly hemolyzed.. The accuracy of the method is ~1mgdL -1 . This phone-based point-of-care system provides the potentially life-saving advantage of a turnaround time of about 10min (versus 4+hours for conventional laboratory analytical methods) and a cost of approximately one dollar USD (assuming you have the phone and the software are already available). Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods.

    PubMed

    Monneret, Denis; Mestari, Fouzi; Atlan, Gregory; Corlouer, Camille; Ramani, Zo; Jaffre, Jeremy; Dever, Sylvie; Fressart, Veronique; Alkouri, Rana; Lamari, Foudil; Devilliers, Catherine; Imbert-Bismut, Françoise; Bonnefont-Rousselot, Dominique

    2015-04-01

    To determine the hemolysis interference on biochemical tests and immunoassays performed on Roche Diagnostics analyzers, according to different maximum allowable limits. Heparinized plasma and serum pools, free of interferences, were overloaded by increasing amounts of a hemoglobin-titrated hemolysate. This interference was evaluated for 45 analytes using Modular(®) and Cobas(®) analyzers. For each parameter, the hemolysis index (HI) corresponding to the traditional ± 10% change of concentrations from baseline (± 10%Δ) was determined, as well as those corresponding to the analytical change limit (ACL), and to the reference change value (RCV). Then, the relative frequencies distribution (% RFD) of hemolyzed tests performed in a hospital laboratory over a 25-day period were established for each HI as allowable limit. Considering the ± 10%Δ, the analyte concentrations enhanced by hemolysis were: Lactate dehydrogenase (LDH), aspartate aminotransferase (AST), folate, potassium, creatine kinase, phosphorus, iron, alanine aminotransferase, lipase, magnesium and triglycerides, decreasingly. The analyte concentrations decreased by hemolysis were: Haptoglobin, high-sensitive troponin T and alkaline phosphatase. Over the 25-day period, the % RFD of tests impacted more than 10%Δ by hemolysis were < 7% for LDH; < 5% for AST, folates and iron; and < 1% for the other analytes. Considering the ACL, HI were lower, giving % RFD substantially increased for many analytes, whereas only four analytes remain sensitive to hemolysis when considering RCV. This study proposes new HI based on different allowable limits, and can therefore serve as a starting point for future harmonization of hemolysis interference evaluation needed in routine laboratory practice.

  10. Intravascular hemolysis induced by the venom of the Eastern coral snake, Micrurus fulvius, in a mouse model: identification of directly hemolytic phospholipases A2.

    PubMed

    Arce-Bejarano, Ruth; Lomonte, Bruno; Gutiérrez, José María

    2014-11-01

    Intravascular hemolysis has been described in envenomings by the Eastern coral snake, Micrurus fulvius, in dogs. An experimental model of intravascular hemolysis was developed in mice after intravenous (i.v.) injection of M. fulvius venom. Within one hr, there was prominent hemolysis, associated with a drastic drop in hematocrit, morphological alterations of erythrocytes, hemoglobinemia, and hemoglobinuria. Hemoglobin was identified in urine by mass spectrometry. Histological sections of kidney revealed abundant hyaline casts, probably corresponding to hemoglobin. This effect was abrogated by p-bromophenacyl bromide, indicating that it is caused by phospholipases A2 (PLA2). A monospecific anti-Micrurus nigrocinctus antivenom neutralized hemolytic activity in vivo. When tested in vitro with erythrocytes of various species, a clear difference in susceptibility was observed. Mouse and dog erythrocytes showed the highest susceptibility, whereas human and rabbit erythrocytes were not affected at the experimental conditions tested. The higher susceptibility of dog and mouse erythrocytes correlates with a high ratio of phosphatidylcholine/sphingomyelin in erythrocyte plasma membrane. When mouse erythrocytes were subjected to mechanical stress, after incubation with venom, hemolysis increased significantly, suggesting that both phospholipid hydrolysis by PLA2s and mechanical stress associated with rheological factors are likely to contribute to cell lysis in vivo. Several PLA2s isolated from this venom reproduced the hemolytic effect, and the complete amino acid sequence of one of them (fraction 17), which also induces myotoxicity, is reported. Since very few PLA2s inducing intravascular hemolysis have been described from snake venoms, this enzyme is a valuable tool to identify the structural determinants of hemolytic activity. The mouse model described in this study may be useful to explore the pathophysiology of intravascular hemolysis. Copyright © 2014 Elsevier Ltd

  11. Basic evaluation of typical nanoporous silica nanoparticles in being drug carrier: Structure, wettability and hemolysis.

    PubMed

    Li, Jing; Guo, Yingyu

    2017-04-01

    Herein, the present work devoted to study the basic capacity of nanoporous silica nanoparticles in being drug carrier that covered structure, wettability and hemolysis so as to provide crucial evaluation. Typical nanoporous silica nanoparticles that consist of nanoporous silica nanoparticles (NSN), amino modified nanoporous silica nanoparticles (amino-NSN), carboxyl modified nanoporous silica nanoparticles (carboxyl-NSN) and hierachical nanoporous silica nanoparticles (hierachical-NSN) were studied. The results showed that their wettability and hemolysis were closely related to structure and surface modification. Basically, wettability became stronger as the amount of OH on the surface of NSN was higher. Both large nanopores and surface modification can reduce the wettability of NSN. Furthermore, NSN series were safe to be used when they circulated into the blood in low concentration, while if high concentration can not be avoided during administration, high porosity or amino modification of NSN were safer to be considered. It is believed that the basic evaluation of NSN can make contribution in providing scientific instruction for designing drug loaded NSN systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Prolonged Neutrophil Dysfunction Following Plasmodium falciparum Malaria is Related to Hemolysis and Heme Oxygenase-1 Induction1

    PubMed Central

    Cunnington, Aubrey J.; Njie, Madi; Correa, Simon; Takem, Ebako N.; Riley, Eleanor M.; Walther, Michael

    2012-01-01

    It is not known why people are more susceptible to bacterial infections such as non-Typhoid Salmonella (NTS) during and after a malaria infection but, in mice, malarial hemolysis impairs resistance to NTS by impairing the neutrophil oxidative burst. This acquired neutrophil dysfunction is a consequence of induction of the cytoprotective, heme degrading enzyme heme oxygenase-1 (HO-1) in neutrophil progenitors in bone marrow. In this study, we assessed whether neutrophil dysfunction occurs in humans with malaria and how this relates to hemolysis. We evaluated neutrophil function in 58 Gambian children with Plasmodium falciparum malaria (55 (95%) with uncomplicated disease), and examined associations with erythrocyte count, haptoglobin, hemopexin, plasma heme, expression of receptors for heme uptake, and HO-1 induction. Malaria caused the appearance of a dominant population of neutrophils with reduced oxidative burst activity, which gradually normalized over 8 weeks of follow-up. The degree of neutrophil impairment correlated significantly with markers of hemolysis and HO-1 induction. HO-1 expression was increased in blood during acute malaria, but at a cellular level HO-1 expression was modulated by changes in surface expression of the haptoglobin receptor (CD163). These findings demonstrate that neutrophil dysfunction occurs in P. falciparum malaria and support the relevance of the mechanistic studies in mice. Furthermore, they suggest the presence of a regulatory pathway to limit HO-1 induction by hemolysis in the context of infection, and indicate new targets for therapeutic intervention to abrogate the susceptibility to bacterial infection in the context of hemolysis in humans. PMID:23100518

  13. Spray drying for preservation of erythrocytes: effect of atomization on hemolysis.

    PubMed

    McLean, Mary; Han, Xiao-Yue; Higgins, Adam Z

    2013-04-01

    Spray drying has the potential to enable storage of erythrocytes at room temperature in the dry state. The spray drying process involves atomization of a liquid into small droplets and drying of the droplets in a gas stream. In this short report, we focus on the atomization process. To decouple atomization from drying, erythrocyte suspensions were sprayed with a two-fluid atomizer nozzle using humid nitrogen as the atomizing gas. The median droplet size was less than 100 μm for all of the spray conditions investigated, indicating that the suspensions were successfully atomized. Hemolysis was significantly affected by the hematocrit of the erythrocyte suspension, the suspension flow rate, and the atomizing gas flow rate (p<0.01 in all cases). Under appropriate conditions, it was possible to achieve less than 2% hemolysis, suggesting that spray drying may be a feasible option for erythrocyte biopreservation.

  14. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia.

    PubMed

    Poder, Thomas G; Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia.

  15. Screening for Saponins Using the Blood Hemolysis Test. An Undergraduate Laboratory Experiment.

    ERIC Educational Resources Information Center

    Sotheeswaran, Subramaniam

    1988-01-01

    Describes an experiment for undergraduate chemistry laboratories involving a chemical found in plants and some sea animals. Discusses collection and identification of material, a hemolysis test, preparation of blood-coated agar plates, and application of samples. (CW)

  16. Is Efficacy of the Anti-Cd20 Antibody Rituximab Preventing Hemolysis Due to Passenger Lymphocyte Syndrome?

    PubMed

    Tsujimura, Kazuma; Ishida, Hideki; Tanabe, Kazunari

    2017-02-01

    Passenger lymphocyte syndrome (PLS) often occurs after ABO-mismatched solid organ and/or bone marrow transplantation between a donor and recipient. Viable donor B-lymphocytes transferred during organ transplantation produce antibodies against recipient red cell antigens, leading to hemolysis. The incidence of PLS has been reported to be around 9% after renal transplantation. A previous report showed that rituximab (Rit) was useful for treatment of PLS in allogeneic stem cell transplantation, bowel transplant and severe cases of hemolysis. However, the effectiveness of Rit in preventing PLS after renal transplantation has not yet been evaluated. The participants in this study were 85 patients who had undergone ABO-mismatched renal transplantation from January 2005 to April 2013. Rit was administered to these patients before transplantation. None of the patients that received Rit treatment developed PLS. Thus administration of Rit before transplantation effectively controlled the production of antibodies by B-lymphocytes, which probably prevented the development of PLS. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  17. An approach to reducing hemolysis in an axial-flow blood pump.

    PubMed

    Anai, H; Nakatani, T; Wakisaka, Y; Araki, K; Taenaka, Y; Tatsumi, E; Masuzawa, T; Baba, Y; Eya, K; Toda, K

    1995-01-01

    In an attempt to decrease hemolysis caused by an axial-flow blood pump, we studied whether specific speed (Ns) at a design point (determined by flow in m3/min, pump head in m, and pump speeds in rpm), should be kept within the existing engineering standard range (1000 < Ns < 2500) or whether pump speed should be reduced to a minimum (Ns < 1000). Four pumps (A: 14,000 rpm, B: 18,000 rpm, C: 22,000 rpm, and D: 26,000 rpm), each with an impeller 11.8 mm in diameter, were designed to accommodate a flow rate of 5 L/min and a pressure head of 100 mmHg. At this design point, the Ns of each pump was calculated as A:758, B:974, C:1191, and D:1407. Pump performance was observed, and the total efficiency of each pump was calculated. The hemolysis index (HI) was calculated after simultaneous testing in duplicate of all four pumps using fresh goat blood (anticoagulated with citrate-dextrose solution) in a closed mock-loop circuit. Total efficiency of each pump was calculated as A:49%, B:50%, C:45%, and D:22%. In the first hemolytic test, HIs were measured as A:0.066, B:0.18, and C:0.13; a water seal failed in pump D. In the second test, HIs were B:0.077, C:0.0499, and D:0.12; a bearing failed in pump A. It is concluded that a lower level of hemolysis is associated with a pump speed in the minimum range at the design point, even though Ns is outside the standard range.

  18. L-Sorbose but not D-tagatose induces hemolysis of dog erythrocytes in vitro.

    PubMed

    Bär, A; Leeman, W R

    1999-04-01

    Previous investigations have demonstrated that L-sorbose induces hemolysis of dog erythrocytes. This effect is probably the consequence of an ATP depletion of the red blood cells subsequent to inhibition of hexokinase, and thus the glycolytic pathway, by sorbose 1-phosphate. In the present study, the susceptibility of dog erythrocytes to D-tagatose, a stereoisomer of L-sorbose, was examined. Washed dog erythrocytes were suspended in Hanks' balanced salt solution (HBSS, containing 5.6 mM glucose) with or without the addition of 0.6, 6, and 60 mM L-sorbose or D-tagatose, or in HBSS with total glucose concentrations of 5.6, 6 and 60 mM D-glucose. After incubation for 24 h at 34 degrees C, the suspensions were centrifuged, and the percentage of hemolysis was determined by measuring the hemoglobin in the sediment and the supernatant. The amount of hemoglobin released in the medium did not differ significantly between the control (HBSS) and the test incubations with glucose or D-tagatose supplementation. In contrast, the addition of 6 and 60 mM L-sorbose resulted in significant hemolysis. At the low dose (0.6 mM), L-sorbose did not have an adverse effect. It is concluded that D-tagatose, unlike L-sorbose, does not have a hemolytic effect on canine erythrocytes. Copyright 1999 Academic Press.

  19. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia

    PubMed Central

    Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K.; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Background Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Methods Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. Results We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. Conclusion To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia. PMID:27711116

  20. Hemolysis of human red blood cells induced by the combination of diethyldithiocarbamate (DDC) and divalent metals: modulation by anaerobiosis, certain antioxidants and oxidants.

    PubMed

    Ginsburg, I; Sadovnic, M; Varani, J; Tirosh, O; Kohen, R

    1999-08-01

    The objective of the present communication is to describe the role played by combinations between diethydithiocarbamate (DDC) and divalent metals in hemolysis of human RBC. RBC which had been treated with DDC (10-50 microM) were moderately hemolyzed (about 50%) upon the addition of subtoxic amounts of Cu2+ (50 microM). However, a much stronger and a faster hemolysis occurred either if mixtures of RBC-DDC were immediately treated either by Co2+ (50 microM) or by a premixture of Cu2+ and Co2+ (Cu:Co) (50 microM). While Fe2+ and Ni2+, at 50 microM, initiated 30-50% hemolysis when combined with DDC (50 microM), on a molar basis, Cd2+ was at least 50 fold more efficient than any of the other metals in the initiation of hemolysis by DDC. On the other hand, neither Mn2+ nor Zn2+, had any hemolysis-initiating effects. Co2+ was the only metal which totally blocked hemolysis if added to DDC prior to the addition of the other metals. Hemolysis by mixtures of DDC + (Cu:Co) was strongly inhibited by anaerobiosis (flushing with nitrogen gas), by the reducing agents glutathione, N-acetyl cysteine, mercaptosuccinate, ascorbate, TEMPO, and alpha-tocopherol, by the PLA2 inhibitorbromophenacylbromide (BrPACBr), by tetracycline as well as by phosphatidyl choline, cholesterol and by trypan blue. However, TEMPO, BrPACBr and PC were the only agents which inhibited hemolysis induced by DDC: Cd2+ complexes. On the other hand, none of the classical scavengers of reactive oxygen species (ROS) employed e.g dimethylthiourea, catalase, histidine, mannitol, sodium benzoate, nor the metal chelators desferal and phenanthroline, had any appreciable inhibitory effects on hemolysis induced by DDC + (Cu:Co). DDC oxidized by H2O2 lost its capacity to act in concert either with Cu2+ or with Cd2+ to hemolyze RBC. While either heating RBC to temperatures greater than 37 degrees C or exposure of the cells to glucose-oxidase-generated peroxide diminished their susceptibility to hemolysis, exposure to the

  1. Glomerular Hyperfiltration in Adult Sickle Cell Anemia: A Frequent Hemolysis Associated Feature

    PubMed Central

    Stankovic, Katia; Levy, Pierre; Avellino, Virginie; Tharaux, Pierre-Louis; Letavernier, Emmanuel; Grateau, Gilles; Baud, Laurent; Girot, Robert; Lionnet, François

    2010-01-01

    Background and objectives: Sickle cell anemia-associated nephropathy is a growing matter of concern because renal failure affects most aging sickle cell anemia patients. Glomerular damage is a common feature revealed by a microalbuminuria or a macroalbuminuria. Although glomerular hyperfiltration has been described for decades in this population, its prevalence in young adults is unknown. Design, setting, participants, & measurements: To address this issue, as well as the clinical and biologic correlates of hyperfiltration, a single-center, cross-sectional study of 280 homozygous SS disease patients was performed. Results: The prevalence of hyperfiltration assessed by Modification of Diet in Renal Disease estimated GFR was 51%. Among patients with hyperfiltration, 49% had hyperfiltration alone, whereas 36% and 15% had an associated microalbuminuria or macroalbuminuria, respectively. Estimated GFR sensitivity and specificity for hyperfiltration were 94% and 63%, respectively, in a selected subgroup of 48 patients (measured GFR was assessed by urinary 51Cr EDTA clearance). In patients with no albuminuria, hyperfiltration status was significantly associated with a young age (years), the absence of alpha thalassemia, a lower hemoglobin level (g/dl), and a lower fetal hemoglobin. The role of chronic hemolysis was further strengthened by multivariate analysis showing a correlation between estimated GFR and a low plasma fetal hemoglobin level, a young age, and a high reticulocyte count (r2 = 0.54). Conclusions: Together, the data suggest that the pathophysiology of hyperfiltration would rather be attributable to the hemolysis-associated vasculopathy rather than a viscosity-vaso-occlusive process. PMID:20185605

  2. A Reusable, Compliant, Small Volume Blood Reservoir for In Vitro Hemolysis Testing.

    PubMed

    Olia, Salim E; Herbertson, Luke H; Malinauskas, Richard A; Kameneva, Marina V

    2017-02-01

    Bench-top in vitro hemolysis testing is a fundamental tool during the design and regulatory safety evaluation of blood-contacting medical devices. While multiple published experimental protocols exist, descriptions of the test loop reservoir remain ambiguous. A critical fixture within the circuit, there is no readily available blood reservoir that ensures thorough mixing and complete air evacuation: two major factors which can affect results. As part of the Food and Drug Administration (FDA) Critical Path Initiative, we developed a three-piece reservoir consisting of a 3D-printed base, a plastic clamp set, and a medical-grade blood bag. This simple, reusable, and cost-effective design was used successfully in the hemolysis assessment of FDA benchmark nozzles and prototype rotary blood pumps, and may be useful as an integral component to any in vitro blood circulation loop. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Evidence for a protective role of the Gardos channel against hemolysis in murine spherocytosis.

    PubMed

    De Franceschi, Lucia; Rivera, Alicia; Fleming, Mark D; Honczarenko, Marek; Peters, Luanne L; Gascard, Philippe; Mohandas, Narla; Brugnara, Carlo

    2005-08-15

    It has been shown that mice with complete deficiency of all 4.1R protein isoforms (4.1-/-) exhibit moderate hemolytic anemia, with abnormal erythrocyte morphology (spherocytosis) and decreased membrane stability. Here, we characterized the Gardos channel function in vitro and in vivo in erythrocytes of 4.1-/- mice. Compared with wild-type, the Gardos channel of 4.1-/- erythrocytes showed an increase in Vmax (9.75 +/- 1.06 vs 6.08 +/- 0.09 mM cell x minute; P < .04) and a decrease in Km (1.01 +/- 0.06 vs 1.47 +/- 1.02 microM; P < .03), indicating an increased sensitivity to activation by intracellular calcium. In vivo function of the Gardos channel was assessed by the oral administration of clotrimazole, a well-characterized Gardos channel blocker. Clotrimazole treatment resulted in worsening of anemia and hemolysis, with decreased red cell survival and increased numbers of circulating hyperchromic spherocytes and microspherocytes. Clotrimazole induced similar changes in 4.2-/- and band 3+/- mice, indicating that these effects of the Gardos channel are shared in different models of murine spherocytosis. Thus, potassium and water loss through the Gardos channel may play an important protective role in compensating for the reduced surface-membrane area of hereditary spherocytosis (HS) erythrocytes and reducing hemolysis in erythrocytes with cytoskeletal impairments.

  4. Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters

    PubMed Central

    Lippi, Giuseppe; Cervellin, Gianfranco; Mattiuzzi, Camilla

    2013-01-01

    Background: A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. Materials and methods: We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode. Results: Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40). Conclusions: Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration. PMID:23894864

  5. Improvement of hemolysis in a centrifugal blood pump with hydrodynamic bearings and semi-open impeller.

    PubMed

    Kosaka, Ryo; Yamane, Takashi; Maruyama, Osamu; Nishida, Masahiro; Yada, Toru; Saito, Sakae; Hirai, Shusaku

    2007-01-01

    We have developed a centrifugal blood pump with hydrodynamic bearings and semi-open impeller, and evaluated the levitation performance test and the hemolysis test. This pump is operated without any complicated control circuit and displacement-sensing module. The casing diameter is 74 mm and the height is 38 mm including flanges for volts. The weight is 251 g and the volume is 159 cm3. By changing the stator relative position against the rotor, the levitation characteristics of the impeller can be adjusted. The diameter of impeller is 36 mm and the height is 25 mm. The impeller is levitated by the thrust bearing of spiral groove type and a radial bearing of herringbone type. The pump performance was evaluated through the levitation performance test and the hemolysis test. As a result, the normalized index of hemolysis (NIH) was reduced from 0.72 g/100 L to 0.024 g/100 L corresponding to the changes of the groove direction of the hydrodynamic bearing and the expansion of the bearing gap. During these studies, we confirmed that the hemolytic property was improved by balancing the fluid dynamic force and the magnetic force.

  6. Bothrops jararaca envenomation: Pathogenesis of hemostatic disturbances and intravascular hemolysis.

    PubMed

    Senise, Luana V; Yamashita, Karine M; Santoro, Marcelo L

    2015-11-01

    To attain fully functional biological activity, vitamin-K dependent coagulation factors (VKDCF) are γ-carboxylated prior to secretion from liver. Warfarin impairs the γ-carboxylation, and consequently their physiological function. Bothrops jararaca snake venom (BjV) contains several activators of blood coagulation, especially procoagulant enzymes (prothrombin and factor X activators) and thrombin-like enzymes. In order to clarify the relative contribution of prothrombin and factor X activators to the hemostatic disturbances occurring during experimental B. jararaca envenomation, warfarin was used to deplete VKDCF, prior to BjV administration. Male Wistar rats were pretreated with saline (Sal) or warfarin (War) and inoculated subsequently with BjV or saline, thus forming four groups: Sal + Sal (negative control), Sal + BjV (positive control), War + Sal (warfarinization control), and War + BjV. Three hours after inoculation, prothrombin and factor X levels fell 40% and 50%, respectively; levels of both factors decreased more than 97% in the War + Sal and War + BjV groups. Platelet counts dropped 93% and 76% in Sal + BjV and War + BjV, respectively, and plasma fibrinogen levels decreased 86% exclusively in Sal + BjV. After 6 and 24 h, platelet counts and fibrinogen levels increased progressively. A dramatic augmentation in plasma hemoglobin levels and the presence of schizocytes and microcytes in the Sal + BjV group indicated the development of intravascular hemolysis, which was prevented by warfarin pretreatment. Our findings show that intravascular thrombin generation has the foremost role in the pathogenesis of coagulopathy and intravascular hemolysis, but not in the development of thrombocytopenia, in B. jararaca envenomation in rats; in addition, fibrinogenases (metalloproteinases) may contribute to coagulopathy more than thrombin-like enzymes. © 2015 by the Society for Experimental Biology and Medicine.

  7. Evaluation of automated assays for immunoglobulin G, M, and A measurements in dog and cat serum.

    PubMed

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Caldin, Marco; Tecles, Fernando; Ceron, Jose J

    2013-09-01

    Measurements of immunoglobulins (Igs) in companion animals can be useful to detect deficiencies of the humoral immune system, that can be associated with opportunistic or chronic infections, or other immune-mediated disorders including B-cell neoplasms. The purpose of this study was to evaluate commercially available automated immunoturbidimetric assays designed for human IgG, M, and A measurements in canine and feline serum using species-specific calibrators. Canine and feline serum samples with different IgG, M, and A concentrations were used for the analytical validation of the assays. Intra- and inter-assay precision, linearity under dilution, spiking recovery, and limit of detection were determined. In addition, effects of lipemia, hemolysis, and bilirubinemia were evaluated. Finally, Ig concentrations were determined in small groups of diseased dogs and cats, and compared with healthy groups. Spiking recovery and linearity under dilution tests showed that the assays measured Igs in canine and feline serum samples precisely and accurately. Intra- and inter-assay imprecisions were lower than 15% in all cases. Significantly higher IgG, IgM, and IgA levels were observed in dogs with leishmaniasis, while dogs with pyometra showed a statistically significant increase in IgM and IgA concentrations in comparison with healthy dogs. Significantly higher IgG and IgM levels were observed in FIV-infected cats compared with healthy ones. The automated human Ig assays showed adequate precision and accuracy with serum samples from dogs and cats. Also, they were able to discriminate different concentrations of Igs in healthy and diseased animals. © 2013 American Society for Veterinary Clinical Pathology.

  8. HEMOLYSIS AND HYPERBILIRUBINEMIA IN ABO BLOOD GROUP HETEROSPECIFIC NEONATES

    PubMed Central

    Kaplan, Michael; Hammerman, Cathy; Vreman, Hendrik J; Wong, Ronald J; Stevenson, David K

    2010-01-01

    Objective We quantified hemolysis and determined the incidence of hyperbilirubinemia in direct antiglobulin titer (DAT) positive, ABO heterospecific neonates and compared variables among O-A and O-B subgroups. Study design Plasma total bilirubin (PTB) was determined predischarge and more frequently if clinically warranted, in DAT positive, blood group A or B neonates of group O mothers. Heme catabolism (and therefore bilirubin production) was indexed by blood carboxyhemoglobin corrected for inspired carbon monoxide (COHbc). Hyperbilirubinemia was defined as any PTB concentration >95th percentile on the hour-of-life-specific bilirubin nomogram. Results Of 164 neonates, 111 were O-A and 53 O-B. Overall, 85 (51.8%) developed hyperbilirubinemia, which tended to be more prevalent in the O-B than O-A neonates (62.3% vs. 46.8% respectively, p=0.053). Importantly, more O-B than O-A newborns developed hyperbilirubinemia at <24 hours (93.9% vs. 48.1%, p<0.0001). COHbc values were globally higher than our previously published newborn values. Babies who developed hyperbilirubinemia had higher COHbc values than the already high values of those non-hyperbilirubinemic, and O-B newborns tended to have higher values than O-A counterparts. Conclusions DAT positive, ABO heterospecificity is associated with increased hemolysis and a high incidence of neonatal hyperbilirubinemia. O-B heterospecificity tends to confer even higher risk than O-A counterparts. PMID:20598320

  9. Unsuspected glucose-6-phosphate dehydrogenase deficiency presenting as symptomatic methemoglobinemia with severe hemolysis after fava bean ingestion in a 6-year-old boy.

    PubMed

    Odièvre, Marie-Hélène; Danékova, Névéna; Mesples, Bettina; Chemouny, Myriam; Couque, Nathalie; Parez, Nathalie; Ducrocq, Rolande; Elion, Jacques

    2011-05-01

    We report the occurrence of symptomatic methemoglobinemia in a previously healthy boy, who presented with severe acute hemolysis after fava bean ingestion. The methemoglobinemia revealed a previously unrecognized glucose-6-phosphate dehydrogenase (G6PD) deficiency. We discuss the pathophysiology of severe methemoglobinemia when associated with acute hemolysis, favism, and the common African G6PD A-variant [G6PD, VAL68MET, ASN126ASP]. In conclusion, screening for G6PD deficiency must be considered in symptomatic methemoglobinemia, especially in young boys, when associated with intravascular hemolysis.

  10. Evidence for a protective role of the Gardos channel against hemolysis in murine spherocytosis

    PubMed Central

    De Franceschi, Lucia; Rivera, Alicia; Fleming, Mark D.; Honczarenko, Marek; Peters, Luanne L.; Gascard, Philippe; Mohandas, Narla; Brugnara, Carlo

    2005-01-01

    It has been shown that mice with complete deficiency of all 4.1R protein isoforms (4.1-/-) exhibit moderate hemolytic anemia, with abnormal erythrocyte morphology (spherocytosis) and decreased membrane stability. Here, we characterized the Gardos channel function in vitro and in vivo in erythrocytes of 4.1-/- mice. Compared with wild-type, the Gardos channel of 4.1-/- erythrocytes showed an increase in Vmax (9.75 ± 1.06 vs 6.08 ± 0.09 mM cell × minute; P < .04) and a decrease in Km (1.01 ± 0.06 vs 1.47 ± 1.02 μM; P < .03), indicating an increased sensitivity to activation by intracellular calcium. In vivo function of the Gardos channel was assessed by the oral administration of clotrimazole, a well-characterized Gardos channel blocker. Clotrimazole treatment resulted in worsening of anemia and hemolysis, with decreased red cell survival and increased numbers of circulating hyperchromic spherocytes and microspherocytes. Clotrimazole induced similar changes in 4.2-/- and band 3+/- mice, indicating that these effects of the Gardos channel are shared in different models of murine spherocytosis. Thus, potassium and water loss through the Gardos channel may play an important protective role in compensating for the reduced surface-membrane area of hereditary spherocytosis (HS) erythrocytes and reducing hemolysis in erythrocytes with cytoskeletal impairments. (Blood. 2005;106:1454-1459) PMID:15855279

  11. First Trimester Hemolysis, Elevated Liver Enzymes, Low Platelets Syndrome in a Surrogate Pregnancy.

    PubMed

    Myer, Emily; Hill, James

    2015-10-01

    Background The occurrence of hemolysis, elevated liver enzymes, low platelets (HELLP) syndrome before 20 weeks of gestation is rare. HELLP is a possible but rare syndrome in gestational surrogate pregnancies for surrogates with risk factors for development of preeclampsia. Case A 32-year-old patient with chronic hypertension and positive antinuclear antibody presented for prenatal care at 13 weeks and 1 day. She was a surrogate for the embryo of a 43-year-old couple. By 15 weeks she developed uncontrolled hypertension requiring hospitalization. She was expectantly managed until her condition deteriorated. At 16 weeks and 1 day she developed hemolysis, elevated liver enzymes, thrombocytopenia, and fetal demise. Conclusions HELLP syndrome is rare and carries a significant morbidity and mortality for the mother and fetus. Clinicians should encourage the surrogate to share her medical history with the embryo donor for appropriate counseling on pregnancy risks.

  12. Hemolysis During Open-Heart Surgery With Vacuum-Assisted Venous Drainage at Different Negative Pressures in Pediatric Patients Weighing Less Than 10 kilograms.

    PubMed

    Kwak, Jae Gun; Lee, Jinkwon; Park, Minkyoung; Seo, Yu-Jin; Lee, Chang-Ha

    2017-03-01

    This study examined the degree of hemolysis during vacuum-assisted venous drainage at different negative pressures to identify an adequate negative pressure that provides effective venous drainage without significant hemolysis in open-heart surgery in children weighing less than 10 kg. Patients weighing less than 10 kg who underwent surgery for ventricular septal defect or atrial septal defect from 2011 to 2014 were enrolled. We used one of four negative pressures (20, 30, 40, or 60 mm Hg) for each patient. We measured haptoglobin, plasma hemoglobin, aspartate aminotransferase, and lactate dehydrogenase levels in the patients' blood three times perioperatively and determined the potential correlation between the change in each parameter with the level of negative pressure. Forty-six patients were enrolled in this study (mean age: 7.1 ± 7.0 months, mean body weight: 6.1 ± 1.8 kg). There were no significant differences according to the degree of negative pressure with respect to patient age, body weight, cardiopulmonary bypass (CPB) time, aorta cross-clamping time, blood flow during CPB, or lowest body temperature. All parameters that we measured reflected progression of hemolysis during CPB; however, the degree of change in the parameters did not correlate with negative pressure. In pediatric patients weighing less than 10 kg, the change in the degree of hemolysis did not differ with the amount of negative pressure. We may apply negative pressures up to 60 mm Hg without increasing the risk of hemolysis, with almost same the level of hemolysis using negative pressures of 20, 30, and 40 mm Hg for effective venous drainage and an ideal operative field during open-heart surgery.

  13. Evaluation of bilirubin concentration in hemolysed samples, is it really impossible? The altitude-curve cartography approach to interfered assays.

    PubMed

    Brunori, Paola; Masi, Piergiorgio; Faggiani, Luigi; Villani, Luciano; Tronchin, Michele; Galli, Claudio; Laube, Clarissa; Leoni, Antonella; Demi, Maila; La Gioia, Antonio

    2011-04-11

    Neonatal jaundice might lead to severe clinical consequences. Measurement of bilirubin in samples is interfered by hemolysis. Over a method-depending cut-off value of measured hemolysis, bilirubin value is not accepted and a new sample is required for evaluation although this is not always possible, especially with newborns and cachectic oncological patients. When usage of different methods, less prone to interferences, is not feasible an alternative recovery method for analytical significance of rejected data might help clinicians to take appropriate decisions. We studied the effects of hemolysis over total bilirubin measurement, comparing hemolysis-interfered bilirubin measurement with the non-interfered value. Interference curves were extrapolated over a wide range of bilirubin (0-30 mg/mL) and hemolysis (H Index 0-1100). Interference "altitude" curves were calculated and plotted. A bimodal acceptance table was calculated. Non-interfered bilirubin of given samples was calculated, by linear interpolation between the nearest lower and upper interference curves. Rejection of interference-sensitive data from hemolysed samples for every method should be based not upon the interferent concentration but upon a more complex algorithm based upon the concentration-dependent bimodal interaction between the interfered analyte and the measured interferent. The altitude-curve cartography approach to interfered assays may help laboratories to build up their own method-dependent algorithm and to improve the trueness of their data by choosing a cut-off value different from the one (-10% interference) proposed by manufacturers. When re-sampling or an alternative method is not available the altitude-curve cartography approach might also represent an alternative recovery method for analytical significance of rejected data. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Impact of Hot Environment on Fluid and Electrolyte Imbalance, Renal Damage, Hemolysis, and Immune Activation Postmarathon

    PubMed Central

    Oliveira, Rodrigo Assunção; Sierra, Ana Paula Rennó; Benetti, Marino; Ghorayeb, Nabil; Sierra, Carlos A.; Kiss, Maria Augusta Peduti Dal Molin

    2017-01-01

    Previous studies have demonstrated the physiological changes induced by exercise exposure in hot environments. We investigated the hematological and oxidative changes and tissue damage induced by marathon race in different thermal conditions. Twenty-six male runners completed the São Paulo International Marathon both in hot environment (HE) and in temperate environment (TE). Blood and urine samples were collected 1 day before, immediately after, 1 day after, and 3 days after the marathon to analyze the hematological parameters, electrolytes, markers of tissue damage, and oxidative status. In both environments, the marathon race promotes fluid and electrolyte imbalance, hemolysis, oxidative stress, immune activation, and tissue damage. The marathon runner's performance was approximately 13.5% lower in HE compared to TE; however, in HE, our results demonstrated more pronounced fluid and electrolyte imbalance, renal damage, hemolysis, and immune activation. Moreover, oxidative stress induced by marathon in HE is presumed to be related to protein/purine oxidation instead of other oxidative sources. Fluid and electrolyte imbalance and protein/purine oxidation may be important factors responsible for hemolysis, renal damage, immune activation, and impaired performance after long-term exercise in HE. Nonetheless, we suggested that the impairment on performance in HE was not associated to the muscle damage and lipoperoxidation. PMID:29430287

  15. Hemolysis and free hemoglobin revisited: exploring hemoglobin and hemin scavengers as a novel class of therapeutic proteins.

    PubMed

    Schaer, Dominik J; Buehler, Paul W; Alayash, Abdu I; Belcher, John D; Vercellotti, Gregory M

    2013-02-21

    Hemolysis occurs in many hematologic and nonhematologic diseases. Extracellular hemoglobin (Hb) has been found to trigger specific pathophysiologies that are associated with adverse clinical outcomes in patients with hemolysis, such as acute and chronic vascular disease, inflammation, thrombosis, and renal impairment. Among the molecular characteristics of extracellular Hb, translocation of the molecule into the extravascular space, oxidative and nitric oxide reactions, hemin release, and molecular signaling effects of hemin appear to be the most critical. Limited clinical experience with a plasma-derived haptoglobin (Hp) product in Japan and more recent preclinical animal studies suggest that the natural Hb and the hemin-scavenger proteins Hp and hemopexin have a strong potential to neutralize the adverse physiologic effects of Hb and hemin. This includes conditions that are as diverse as RBC transfusion, sickle cell disease, sepsis, and extracorporeal circulation. This perspective reviews the principal mechanisms of Hb and hemin toxicity in different disease states, updates how the natural scavengers efficiently control these toxic moieties, and explores critical issues in the development of human plasma-derived Hp and hemopexin as therapeutics for patients with excessive intravascular hemolysis.

  16. Benzaldehyde Schiff bases regulation to the metabolism, hemolysis, and virulence genes expression in vitro and their structure-microbicidal activity relationship.

    PubMed

    Xia, Lei; Xia, Yu-Fen; Huang, Li-Rong; Xiao, Xiao; Lou, Hua-Yong; Liu, Tang-Jingjun; Pan, Wei-Dong; Luo, Heng

    2015-06-05

    There is an urgent need to develop new antibacterial agents because of multidrug resistance by bacteria and fungi. Schiff bases (aldehyde or ketone-like compounds) exhibit intense antibacterial characteristics, and are therefore, promising candidates as antibacterial agents. To investigate the mechanism of action of newly designed benzaldehyde Schiff bases, a series of high-yielding benzaldehyde Schiff bases were synthesized, and their structures were determined by NMR and MS spectra data. The structure-microbicidal activity relationship of derivatives was investigated, and the antibacterial mechanisms were investigated by gene assays for the expression of functional genes in vitro using Escherichia coli, Staphylococcus aureus, and Bacillus subtilis. The active compounds were selective for certain active groups. The polar substitution of the R2 group of the amino acids in the Schiff bases, affected the antibacterial activity against E. coli and S. aureus; specific active group at the R3 or R4 groups of the acylhydrazone Schiff bases could improve their inhibitory activity against these three tested organisms. The antibacterial mechanism of the active benzaldehyde Schiff bases appeared to regulate the expression of metabolism-associated genes in E. coli, hemolysis-associated genes in B. subtilis, and key virulence genes in S. aureus. Some benzaldehyde Schiff bases were bactericidal to all the three strains and appeared to regulate gene expression associated with metabolism, hemolysis, and virulence, in vitro. The newly designed benzaldehyde Schiff bases possessed unique antibacterial activity and might be potentially useful for prophylactic or therapeutic intervention of bacterial infections. Copyright © 2015. Published by Elsevier Masson SAS.

  17. Optimal bearing gap of a multiarc radial bearing in a hydrodynamically levitated centrifugal blood pump for the reduction of hemolysis.

    PubMed

    Kosaka, Ryo; Yasui, Kazuya; Nishida, Masahiro; Kawaguchi, Yasuo; Maruyama, Osamu; Yamane, Takashi

    2014-09-01

    We have developed a hydrodynamically levitated centrifugal pump as a bridge-to-decision device. The purpose of the present study is to determine the optimal bearing gap of a multiarc radial bearing in the developed blood pump for the reduction of hemolysis. We prepared eight pump models having bearing gaps of 20, 30, 40, 80, 90, 100, 180, and 250 μm. The driving conditions were set to a pressure head of 200 mm Hg and a flow rate of 4 L/min. First, the orbital radius of the impeller was measured for the evaluation of the impeller stability. Second, the hemolytic property was evaluated in an in vitro hemolysis test. As a result, the orbital radius was not greater than 15 μm when the bearing gap was between 20 and 100 μm. The relative normalized index of hemolysis (NIH) ratios in comparison with BPX-80 were 37.67 (gap: 20 μm), 0.95 (gap: 30 μm), 0.96 (gap: 40 μm), 0.82 (gap: 80 μm), 0.77 (gap: 90 μm), 0.92 (gap: 100 μm), 2.76 (gap: 180 μm), and 2.78 (gap: 250 μm). The hemolysis tended to increase at bearing gaps of greater than 100 μm due to impeller instability. When the bearing gap decreased from 30 to 20 μm, the relative NIH ratios increased significantly from 0.95 to 37.67 times (P < 0.01) due to high shear stress. We confirmed that the optimal bearing gap was determined between 30 and 100 μm in the developed blood pump for the reduction of hemolysis. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Mechanical Blood Trauma in Assisted Circulation: Sublethal RBC Damage Preceding Hemolysis

    PubMed Central

    Olia, Salim E.; Maul, Timothy M.; Antaki, James F.; Kameneva, Marina V.

    2016-01-01

    After many decades of improvements in mechanical circulatory assist devices (CADs), blood damage remains a serious problem during support contributing to variety of adverse events, and consequently affecting patient survival and quality of life. The mechanisms of cumulative cell damage in continuous-flow blood pumps are still not fully understood despite numerous in vitro, in vivo, and in silico studies of blood trauma. Previous investigations have almost exclusively focused on lethal blood damage, namely hemolysis, which is typically negligible during normal operation of current generation CADs. The measurement of plasma free hemoglobin (plfHb) concentration to characterize hemolysis is straightforward, however sublethal trauma is more difficult to detect and quantify since no simple direct test exists. Similarly, while multiple studies have focused on thrombosis within blood pumps and accessories, sublethal blood trauma and its sequelae have yet to be adequately documented or characterized. This review summarizes the current understanding of sublethal trauma to red blood cells (RBCs) produced by exposure of blood to flow parameters and conditions similar to those within CADs. It also suggests potential strategies to reduce and/or prevent RBC sublethal damage in a clinically-relevant context, and encourages new research into this relatively uncharted territory. PMID:27034320

  19. Repetitive Supra-Physiological Shear Stress Impairs Red Blood Cell Deformability and Induces Hemolysis.

    PubMed

    Horobin, Jarod T; Sabapathy, Surendran; Simmonds, Michael J

    2017-11-01

    The supra-physiological shear stress that blood is exposed to while traversing mechanical circulatory assist devices affects the physical properties of red blood cells (RBCs), impairs RBC deformability, and may induce hemolysis. Previous studies exploring RBC damage following exposure to supra-physiological shear stress have employed durations exceeding clinical instrumentation, thus we explored changes in RBC deformability following exposure to shear stress below the reported "hemolytic threshold" using shear exposure durations per minute (i.e., duty-cycles) reflective of that employed by circulatory assist devices. Blood collected from 20 male donors, aged 18-38 years, was suspended in a viscous medium and exposed to an intermittent shear stress protocol of 1 s at 100 Pa, every 60 s for 60 duty-cycles. During the remaining 59 s/min, the cells were left at stasis until the subsequent duty-cycle commenced. At discrete time points (15/30/45/60 duty-cycles), an ektacytometer measured RBC deformability immediately after shear exposure at 100 Pa. Plasma-free hemoglobin, a measurement of hemolysis, was quantified via spectrophotometry. Supra-physiological shear stress impaired RBC properties, as indicated by: (1) decreased maximal elongation of RBCs at infinite shear stress following 15 duty-cycles (P <0.05); (2) increased real-time RBC deformability during application of the supra-physiological shear stress protocol (100 Pa) following exposure to 1 duty-cycle (F (1.891, 32.15) = 12.21, P = 0.0001); and (3) increased plasma-free hemoglobin following 60 duty-cycles (P < 0.01). The present study indicates that exposure of RBCs to short-term, repeated supra-physiological shear stress, impairs RBC deformability, with the extent of impairment exacerbated with each duty-cycle, and ultimately precipitates hemolysis. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. An enzymatic assay based on luciferase Ebola virus-like particles for evaluation of virolytic activity of antimicrobial peptides.

    PubMed

    Peskova, Marie; Heger, Zbynek; Janda, Petr; Adam, Vojtech; Pekarik, Vladimir

    2017-02-01

    Antimicrobial peptides are currently considered as promising antiviral compounds. Current assays to evaluate the effectivity of peptides against enveloped viruses based on liposomes or hemolysis are encumbered by the artificial nature of liposomes or distinctive membrane composition of used erythrocytes. We propose a novel assay system based on enzymatic Ebola virus-like particles containing sensitive luciferase reporter. The assay was validated with several cationic and anionic peptides and compared with lentivirus inactivation and hemolytic assays. The assay is sensitive and easy to perform in standard biosafety level laboratory with potential for high-throughput screens. The use of virus-like particles in the assay provides a system as closely related to the native viruses as possible eliminating some issues associated with other more artificial set ups. We have identified CAM-W (KWKLWKKIEKWGQGIGAVLKWLTTWL) as a peptide with the greatest antiviral activity against infectious lentiviral vectors and filoviral virus-like particles. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Hemolysis related to intravenous immunoglobulins is dependent on the presence of anti-blood group A and B antibodies and individual susceptibility.

    PubMed

    Mielke, Orell; Fontana, Stefano; Goranova-Marinova, Vesselina; Shebl, Amgad; Spycher, Martin O; Wymann, Sandra; Durn, Billie L; Lawo, John P; Hubsch, Alphonse; Salama, Abdulgabar

    2017-11-01

    Patients treated with intravenous immunoglobulins (IVIG) rarely experience symptomatic hemolysis. Although anti-A and anti-B isoagglutinins from the product are involved in most cases, the actual mechanisms triggering hemolysis are unclear. A prospective, open-label, multicenter, single-arm clinical trial in 57 patients with immune thrombocytopenia treated with IVIG (Privigen, CSL Behring) was conducted. Twenty-one patients received one infusion (1 g/kg) and 36 received two infusions (2 × 1 g/kg) of IVIG. After a study duration of more than 2 years, no cases of clinically significant hemolysis as defined in the protocol were identified. Data of patients with mild hematologic and biochemical changes were analyzed in more detail. Twelve cases (10/23 patients with blood group A1 and 2/11 patients with blood group B, all having received 2 g/kg IVIG) were adjudicated as mild hemolysis (median hemoglobin [Hb] decrease, -3.0 g/dL); Hb decreases were transient, with partial or full recovery achieved by last visit. Eighteen patients (31.6%), all with non-O blood group, of whom 16 (88.9%) received 2 g/kg IVIG, fulfilled post hoc criteria for hemolytic laboratory reactions. Red blood cell (RBC) eluates of all direct antiglobulin test-positive samples were negative for non-ABO blood group antibodies. Blood groups A and B antigen density on RBCs appeared to be a risk factor for hemolytic laboratory reactions. Platelet response to treatment was observed in 42 patients (74%); eight of 12 patients with complete response had blood group A1. Isoagglutinins are involved in clinically nonsignificant hemolysis after treatment with IVIG, but individual susceptibility varies greatly. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  2. THE MECHANISM OF THE INHIBITION OF HEMOLYSIS

    PubMed Central

    Ponder, Eric

    1945-01-01

    This paper contains a description of some of the inhibitory, and occasionally acceleratory, effects of sols of lecithins, cholesterol, and proteins in hemolytic systems containing simple lysins, together with investigations on the nature of the reactions by means of which the effects are brought about. The principal conclusions are: A. As regards sols of lecithins. 1. In lysin-inhibitor-cell systems, distearyl lecithin is an inhibitor of saponin and digitonin hemolysis, part of the effect being the result of a reaction with the components of the red cell surface and part being the result of a reaction with lysin in the bulk phase of the system. Lecithin ab ovo (Merck) is an accelerator of saponin hemolysis and either an accelerator or an inhibitor of digitonin hemolysis according to the initial concentration of lysin present in the system. Soybean lecithin is an inhibitor of both saponin and digitonin hemolysis, but both soybean lecithin and lecithin ab ovo contain also a hemolytic, or acceleratory, component. 2. The inhibitory effects depend on the order in which the components of the hemolytic system are mixed together. Distearyl lecithin is about 5 times more inhibitory in cell-inhibitor-lysin systems than in lysin-inhibitor-cell systems containing saponin, digitonin, or taurocholate. Lecithin ab ovo is more inhibitory in cell-inhibitor-lysin systems when the time of contact between cells and inhibitor is short, but when it is long, the hemolytic properties of the lecithin offset its inhibitory properties. A similar state of affairs is observed with soybean lecithin. 3. An increase in temperature decreases the inhibitory effect of distearyl lecithin in systems containing saponin or digitonin. B. As regards sols of cholesterol. 4. The quantity of lysin Δ apparently inhibited by a quantity Q of cholesterol sol is dependent on both the type of red cell and the number of red cells added to the system. 5. Δ is a non-linear function of Q and of c 1, the initial

  3. New centrifugal blood pump with dual impeller and double pivot bearing system: wear evaluation in bearing system, performance tests, and preliminary hemolysis tests.

    PubMed

    Bock, Eduardo; Ribeiro, Adriana; Silva, Maxwell; Antunes, Pedro; Fonseca, Jeison; Legendre, Daniel; Leme, Juliana; Arruda, Celso; Biscegli, José; Nicolosi, Denys; Andrade, Aron

    2008-04-01

    A new dual impeller centrifugal blood pump has been developed as a research collaboration between Baylor College of Medicine and Institute Dante Pazzanese of Cardiology for long-term left ventricle assist device (LVAD). A design feature of this new pump is a dual impeller that aims to minimize a stagnant flow pattern around the inlet port. Several different materials were tested in order to adopt a double pivot bearing design originally developed by Prof. Dr. Yukihiko Nosé from Baylor College of Medicine. Hydraulic performance tests were conducted with two different inlet ports' angle configurations 30 degrees and 45 degrees . Pump with inlet port angle of 45 degrees achieved best values of pressure ahead and flow after 1800 rpm. Preliminary hemolysis tests were conducted using human blood. The pump showed good performance results and no alarming trace of hemolysis, proving to be a feasible long-term LVAD.

  4. Prolonged red cell storage before transfusion increases extravascular hemolysis

    PubMed Central

    Rapido, Francesca; Brittenham, Gary M.; Bandyopadhyay, Sheila; La Carpia, Francesca; L’Acqua, Camilla; McMahon, Donald J.; Rebbaa, Abdelhadi; Wojczyk, Boguslaw S.; Netterwald, Jane; Wang, Hangli; Schwartz, Joseph; Eisenberger, Andrew; Soffing, Mark; Yeh, Randy; Divgi, Chaitanya; Ginzburg, Yelena Z.; Shaz, Beth H.; Sheth, Sujit; Francis, Richard O.; Spitalnik, Steven L.; Hod, Eldad A.

    2016-01-01

    BACKGROUND. Some countries have limited the maximum allowable storage duration for red cells to 5 weeks before transfusion. In the US, red blood cells can be stored for up to 6 weeks, but randomized trials have not assessed the effects of this final week of storage on clinical outcomes. METHODS. Sixty healthy adult volunteers were randomized to a single standard, autologous, leukoreduced, packed red cell transfusion after 1, 2, 3, 4, 5, or 6 weeks of storage (n = 10 per group). 51-Chromium posttransfusion red cell recovery studies were performed and laboratory parameters measured before and at defined times after transfusion. RESULTS. Extravascular hemolysis after transfusion progressively increased with increasing storage time (P < 0.001 for linear trend in the AUC of serum indirect bilirubin and iron levels). Longer storage duration was associated with decreasing posttransfusion red cell recovery (P = 0.002), decreasing elevations in hematocrit (P = 0.02), and increasing serum ferritin (P < 0.0001). After 6 weeks of refrigerated storage, transfusion was followed by increases in AUC for serum iron (P < 0.01), transferrin saturation (P < 0.001), and nontransferrin-bound iron (P < 0.001) as compared with transfusion after 1 to 5 weeks of storage. CONCLUSIONS. After 6 weeks of refrigerated storage, transfusion of autologous red cells to healthy human volunteers increased extravascular hemolysis, saturated serum transferrin, and produced circulating nontransferrin-bound iron. These outcomes, associated with increased risks of harm, provide evidence that the maximal allowable red cell storage duration should be reduced to the minimum sustainable by the blood supply, with 35 days as an attainable goal. REGISTRATION. ClinicalTrials.gov NCT02087514. FUNDING. NIH grant HL115557 and UL1 TR000040. PMID:27941245

  5. Severe hemolysis after plasma transfusion in a neonate with necrotizing enterocolitis, Clostridium perfringens infection, and red blood cell T-polyagglutination.

    PubMed

    Moh-Klaren, Julia; Bodivit, Gwellaouen; Jugie, Myriam; Chadebech, Philippe; Chevret, Laurent; Mokhtari, Mostafa; Chamillard, Xavier; Gallon, Philippe; Tissières, Pierre; Bierling, Philippe; Djoudi, Rachid; Pirenne, France; Burin-des-Roziers, Nicolas

    2017-11-01

    Red blood cell (RBC) Thomsen-Friedenreich antigen exposure (T activation) in infants with necrotizing enterocolitis (NEC) has occasionally been associated with posttransfusional intravascular hemolysis thought to be due to anti-T antibodies in the donor plasma. We describe an infant with NEC and Clostridium perfringens infection complicated by severe hemolysis after plasma transfusion. After this case, infants with confirmed NEC were prospectively evaluated for T activation. We checked for hemolysis in patients with T activation receiving plasma-containing blood products. The infant had received 80 mL of fresh-frozen plasma (FFP). His RBCs displayed strong T activation, and agglutination was observed with four of six ABO-compatible FFP units. A direct antiglobulin test was negative. IgM-class anti-T antibodies were present in small amounts (titer of 8) in the transfused FFP. Anti-T antibodies from the blood donor were not hemolytic in vitro. In the prospective study, T activation was observed in three of 28 infants with NEC (11%). One infant presented moderate T activation and two infants presented very strong T activation but only moderate decreases in sialic acid expression on the RBC membrane. These three infants presented no signs of hemolysis after transfusion with unwashed blood products or FFP. Anti-T antibodies are unlikely to be the etiologic factor for the hemolytic reactions observed in infants with NEC and T activation. Massive RBC desialylation and the direct action of bacterial toxins are more probable causes. Strict avoidance of plasma-containing blood products does not seem justified in these infants. © 2017 AABB.

  6. Molecular Mechanism of Yisui Shengxue Granule, a Complex Chinese Medicine, on Thalassemia Patients Suffering from Hemolysis and Anemia of Erythrocytes

    PubMed Central

    Chu, Na-Li; Wu, Zhi-kui; Zhang, Xin-Hua; Fang, Su-Ping; Wang, Wen-Juan; Cheng, Yan-Ling

    2014-01-01

    The objective of this study was to investigate the therapeutic biological mechanism of Yisui Shengxue Granule (YSSXG), a complex Chinese medicine, on the hemolysis and anemia of erythrocytes from patient with thalassemia disease. Sixteen patients with thalassemia (8 cases of α-thalassemia and 8 cases of β-thalassemia) disease were collected and treated with YSSXG for 3 months. The improvements of blood parameter demonstrated that YSSXG had a positive clinical effect on patients with thalassemia disease. For patients with α-thalassemia disease, RT-PCR showed that YSSXG upregulated the relative mRNA expression level of α-globin to β-globin and downregulated DNMT1, DNMT3a, and DNMT3b mRNA compared with pretreatment. Western blotting showed that YSSXG downregulated the expression of DNMT1 and DNMT3a. For patients with β-thalassemia disease, the relative expression level of A γ-globin to α-globin had an increasing trend and the level of BCL11A mRNA expression obviously increased. For all patients, RT-PCR showed that YSSXG upregulated mRNA expression of SPTA1 and SPTB. Activities of SOD and GSH-Px significantly increased and MDA obviously reduced on erythrocyte and blood serum after YSSXG treatment. TEM showed that YSSXG decreased the content of inclusion bodies. Activities of Na+K+-ATPtase and T-ATPtase of erythrocyte increased significantly after YSSXG treatment. This study provides the basis for mechanisms of YSSXG on thalassemia suffering with hemolysis and anemia of erythrocytes from patient. PMID:25574177

  7. In vitro erythrocyte membrane stabilization properties of Carica papaya L. leaf extracts

    PubMed Central

    Ranasinghe, Priyanga; Ranasinghe, Pathmasiri; Abeysekera, W. P. Kaushalya M.; Premakumara, G. A. Sirimal; Perera, Yashasvi S.; Gurugama, Padmalal; Gunatilake, Saman B.

    2012-01-01

    Background: Carica papaya L. fruit juice and leaf extracts are known to have many beneficial medical properties. Recent reports have claimed possible beneficial effects of C. papaya L. leaf juice in treating patients with dengue viral infections. This study aims to evaluate the membrane stabilization potential of C. papaya L. leaf extracts using an in vitro hemolytic assay. Materials and Methods: The study was conducted in between June and August 2010. Two milliliters of blood from healthy volunteers and patients with serologically confirmed current dengue infection were freshly collected and used in the assays. Fresh papaya leaves at three different maturity stages (immature, partly matured, and matured) were cleaned with distilled water, crushed, and the juice was extracted with 10 ml of cold distilled water. Freshly prepared cold water extracts of papaya leaves (1 ml containing 30 μl of papaya leaf extracts, 20 μl from 40% erythrocytes suspension, and 950 μl of phosphate buffered saline) were used in the heat-induced and hypotonic-induced hemolytic assays. In dose response experiments, six different concentrations (9.375, 18.75, 37.5, 75, 150, and 300 μg/ml) of freeze dried extracts of the partly matured leaves were used. Membrane stabilization properties were investigated with heat-induced and hypotonicity-induced hemolysis assays. Results: Extracts of papaya leaves of all three maturity levels showed a significant reduction in heat-induced hemolysis compared to controls (P < 0.05). Papaya leaf extracts of all three maturity levels showed more than 25% inhibition at a concentration of 37.5 μg/ml. The highest inhibition of heat-induced hemolysis was observed at 37.5 μg/ml. Inhibition activity of different maturity levels was not significantly (P < 0.05) different from one another. Heat-induced hemolysis inhibition activity did not demonstrate a linear dose response relationship. At 37.5 μg/ml concentration of the extract, a marked inhibition of

  8. In vitro erythrocyte membrane stabilization properties of Carica papaya L. leaf extracts.

    PubMed

    Ranasinghe, Priyanga; Ranasinghe, Pathmasiri; Abeysekera, W P Kaushalya M; Premakumara, G A Sirimal; Perera, Yashasvi S; Gurugama, Padmalal; Gunatilake, Saman B

    2012-10-01

    Carica papaya L. fruit juice and leaf extracts are known to have many beneficial medical properties. Recent reports have claimed possible beneficial effects of C. papaya L. leaf juice in treating patients with dengue viral infections. This study aims to evaluate the membrane stabilization potential of C. papaya L. leaf extracts using an in vitro hemolytic assay. The study was conducted in between June and August 2010. Two milliliters of blood from healthy volunteers and patients with serologically confirmed current dengue infection were freshly collected and used in the assays. Fresh papaya leaves at three different maturity stages (immature, partly matured, and matured) were cleaned with distilled water, crushed, and the juice was extracted with 10 ml of cold distilled water. Freshly prepared cold water extracts of papaya leaves (1 ml containing 30 μl of papaya leaf extracts, 20 μl from 40% erythrocytes suspension, and 950 μl of phosphate buffered saline) were used in the heat-induced and hypotonic-induced hemolytic assays. In dose response experiments, six different concentrations (9.375, 18.75, 37.5, 75, 150, and 300 μg/ml) of freeze dried extracts of the partly matured leaves were used. Membrane stabilization properties were investigated with heat-induced and hypotonicity-induced hemolysis assays. Extracts of papaya leaves of all three maturity levels showed a significant reduction in heat-induced hemolysis compared to controls (P < 0.05). Papaya leaf extracts of all three maturity levels showed more than 25% inhibition at a concentration of 37.5 μg/ml. The highest inhibition of heat-induced hemolysis was observed at 37.5 μg/ml. Inhibition activity of different maturity levels was not significantly (P < 0.05) different from one another. Heat-induced hemolysis inhibition activity did not demonstrate a linear dose response relationship. At 37.5 μg/ml concentration of the extract, a marked inhibition of hypotonicity-induced hemolysis was observed. C. papaya

  9. Antihemolytic and antioxidant properties of pearl powder against 2,2'-azobis(2-amidinopropane) dihydrochloride-induced hemolysis and oxidative damage to erythrocyte membrane lipids and proteins.

    PubMed

    Yang, Hsin-Ling; Korivi, Mallikarjuna; Lin, Ming-Kuem; Chang, Hebron Chun-Wei; Wu, Chi-Rei; Lee, Meng-Shiou; Chen, William Tzu-Liang; Hseu, You-Cheng

    2017-10-01

    Pearl powder, a well-known traditional mineral medicine, is reported to be used for well-being and to treat several diseases from centuries in Taiwan and China. We investigated the in vitro antihemolytic and antioxidant properties of pearl powder that could protect erythrocytes against 2,2'-azobis(2-amidinopropane) dihydrochloride (AAPH)-induced oxidative damage to membrane proteins/lipids. Human erythrocytes were incubated with different concentrations of pearl powder (50-200 μg/mL) for 30 minutes and then exposed to AAPH for 2-6 hours. We found that AAPH alone time dependently increased the oxidative hemolysis of erythrocytes, while pearl powder pretreatment substantially inhibited the hemolysis in a concentration-/time-dependent manner. AAPH-induced oxidative damage to erythrocyte membrane lipids was evidenced by the elevated malondialdehyde (MDA) levels. However, pearl powder remarkably inhibited the malondialdehyde formation, and the 200 μg/mL concentration showed almost similar malondialdehyde values to the control. Furthermore, pearl powder suppressed the AAPH-induced high-molecular-weight protein formation and concomitantly increased the low-molecular-weight proteins in erythrocytes. Antioxidant potential that was measured as superoxide dismutase activity and glutathione content was significantly dropped by AAPH incubation, which suggests the vulnerability of erythrocytes to AAPH-induced oxidative stress. Noteworthy, erythrocytes pretreated with pearl powder showed restored superoxide dismutase activity and glutathione levels against AAPH-induced loss. Our findings conclude that pearl powder attenuate free radical-induced hemolysis and oxidative damage to erythrocyte membrane lipids/proteins. The potent antioxidant property of pearl powder may offer protection from free radical-related diseases. Copyright © 2016. Published by Elsevier B.V.

  10. In vitro degradation, hemolysis, and cytocompatibility of PEO/PLLA composite coating on biodegradable AZ31 alloy.

    PubMed

    Wei, Zhongling; Tian, Peng; Liu, Xuanyong; Zhou, Bangxin

    2015-02-01

    Magnesium and its alloys have large potential as degradable and absorbable biomaterials because of their mechanical properties and biocompatibility. However, their corrosion resistance is usually inadequate especially in physiological environment, which limits their broad applications in biomedical areas. In this work, plasma electrolytic oxidized/poly(l-lactide) (PEO/PLLA) composite coating was successfully fabricated on biodegradable AZ31 alloy by combing PEO process and sealing with PLLA. The microstructure, elemental composition, and phase composition of the PEO/PLLA composite coating were investigated. The in vitro degradation of the PEO/PLLA composite coating in simulated body fluid (SBF) was also systematically evaluated. The results revealed that the PEO/PLLA composite coating improved the corrosion resistance of AZ31 alloy significantly. The corrosion potential shifted from -1.663V to more positive position -1.317 V and the corrosion current density was reduced with six-order of magnitude. The Mg(2+) ions, hydrogen release, and pH value change of solution caused by degradation were all decreased significantly. Moreover, the PEO process played a critical role in sustaining the integrity of the implant in long-term service. The result of hemolysis test showed that the PEO/PLLA composite coating vested AZ31 alloy a low hemolysis ratio (0.806 ± 0.771)%, which is much lower than the safe value of 5% according to ISO 10993-4. For the cytocompatibility test, compared with bare AZ31 alloy and PEO coating, MC3T3-E1 cells showed much better adhesion and proliferation on the PEO/PLLA composite coating with nearly 4-fold increase of cells after 7-day cultivation, indicating that the PEO/PLLA composite coating has good biocompatibility for biomedical applications. © 2014 Wiley Periodicals, Inc.

  11. [Assays of HbA1c and Amadori products in human biology].

    PubMed

    Gillery, P

    2014-09-01

    Different Amadori products, formed during the early steps of the non-enzymatic glycation of proteins, may be assayed in current practice in human biology. The most important marker is HbA1c, resulting from the binding of glucose to the N-terminal extremity of HbA beta chains. HbA1c may be evaluated by various techniques (ion exchange or affinity high performance liquid chromatography, capillary electrophoresis, immunoassay, enzymatic technique) and is considered the best marker of diabetic patient survey. Due to its irreversible and cumulative formation, it provides a retrospective information on the glycemic balance over the four to eight weeks preceding blood collection. It benefits from an international standardization, based on a reference method using liquid chromatography coupled to capillary electrophoresis or mass spectrometry, maintained by an international network of reference laboratories. When HbA1c assay cannot be used (anemia, hemolysis, hemoglobinopathy) or when a shorter period of glycemic equilibrium must be evaluated (child and adolescent, pregnancy, therapeutic changes), other Amadori products may be assayed, like plasma fructosamine (all plasma glycated proteins) or glycated albumin. Nevertheless, these assays are less used in practice, because their semiological value has been less evidenced. Besides, fructosamine assay lacks specificity, and glycated albumin assay has been described recently. An expanding use of HbA1c assay is expected, especially for the diagnosis of diabetes mellitus and the evaluation of other risks, especially cardiovascular ones. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Shrimp pathogenicity, hemolysis, and the presence of hemolysin and TTSS genes in Vibrio harveyi isolated from Thailand.

    PubMed

    Rattanama, Pimonsri; Srinitiwarawong, Kanchana; Thompson, Janelle R; Pomwised, Rattanaruji; Supamattaya, Kidchakarn; Vuddhakul, Varaporn

    2009-09-23

    The virulence factors of Vibrio harveyi, the causative agent of luminous vibriosis, are not completely understood. We investigated the correlations between shrimp mortality, hemolysis, the presence of a hemolysin gene (vhh), and a gene involved in the type III secretion system (the Vibrio calcium response gene vcrD). V harveyi HY01 was isolated from a shrimp that died from vibriosis, and 36 other V. harveyi isolates were obtained from fish and shellfish in Hat Yai city, Thailand. An ocean isolate of V. harveyi BAA-1116 was also included. Thirteen isolates including V harveyi HYO1 caused shrimp death 12 h after injection. Most V harveyi isolates in this group (designated as Group A) caused hemolysis on prawn blood agar. None of the shrimp died after injection with V harveyi BAA-1116. Molecular analysis of all V harveyi isolates revealed the presence of vcrD in both pathogenic and non-pathogenic strains. Although vhh was detected in all V harveyi isolates, some isolates did not cause hemolysis, indicating that vhh gene expression might be regulated. Analysis of the V harveyi HYO1 genome revealed a V cholerae like-hemolysin gene, hlyA (designated as hhl). Specific primers designed for hhl detected this gene in 3 additional V harveyi isolates but the presence of this gene was not correlated with pathogenicity. Random amplified polymorphic DNA (RAPD) analysis revealed a high degree of genetic diversity in all V harveyi isolates, and there were no correlations among the hhl-positive isolates or the pathogenic strains.

  13. Predictors of severe hemolysis in patients with glucose-6-phosphate dehydrogenase deficiency following exposure to oxidant stresses.

    PubMed

    Al-Sweedan, Suleimman A; Jdaitawi, Hussein; Khriesat, Wadah M; Khader, Yousef Y; Al-Rimawi, Hala S

    2009-01-01

    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a genetic enzymatic disorder that affects millions of people worldwide, and is a major health problem in Jordan. We studied factors that may predict severe hemolysis in children with G6PD deficiency. We reviewed the records of patients with low G6PD activity admitted to a teaching hospital be- tween 1996 to 2007. We collected demographic data, details of sign and symptoms, history and type of fava bean ingestion, blood and Rh group, history of neonatal jaundice, history and type of drug use, abdominal pain at admission and the results of tests for hemoglobin, white blood cells (WBC), and hepatic function. We classified patients into mild and severe groups based on hemoglobin levels at admission. Of 428 children with G6PD deficiency, 79 (18%) were severe cases and 349 (82%) patients with mild disease. There were no statistically significant differences in most factors between the two groups. Factors that achieved statistical significance for severe hemolysis included younger age (P<.05), male gender (P<.05), higher alkaline phosphatase (ALP) (P<.05), presence of fever at admission (P<.01), presence of vomiting during the at- tack (P=.006), and a negative family history for G6PD deficiency (P=.005). Severe hemolysis can be predicted during hemolytic episodes in children with low G6PD by young age, male gender, a negative family history of G6PD deficiency, the presence of fever and vomiting and a high ALP.

  14. STRUCTURE OF MEMBRANE HOLES IN OSMOTIC AND SAPONIN HEMOLYSIS

    PubMed Central

    Seeman, P.; Cheng, D.; Iles, G. H.

    1973-01-01

    Serial section electron microscopy of hemolysing erythrocytes (fixed at 12 s after the onset of osmotic hemolysis) revealed long slits and holes in the membrane, extending to around 1 µm in length. Many but not all of the slits and holes (about 100–1000 Å wide) were confluent with one another. Ferritin and colloidal gold (added after fixation) only permeated those cells containing membrane defects. No such large holes or slits were seen in saponin-treated erythrocytes, and the membrane was highly invaginated, giving the ghost a scalloped outline. Freeze-etch electron microscopy of saponin-treated membranes revealed 40–50 Å-wide pits in the extracellular surface of the membrane. If these pits represent regions from which cholesterol was extracted, then cholesterol is uniformly distributed over the entire erythrocyte membrane. PMID:4566525

  15. Significances of red cell bound immunoglobulin G as detected by flow cytometry in patients with Coombs-negative immune hemolysis.

    PubMed

    Thedsawad, A; Taka, O; Wanachiwanawin, W

    2016-04-01

    This study was to investigate the use of flow cytometry for detection and quantitation of red blood cells (RBC) bound IgG in immune hemolysis of patients with autoimmune hemolytic anaemia (AIHA) and systematic lupus erythematosus (SLE). Two to ten percent of patients with warm-autoimmune hemolytic anaemia (WAIHA) exhibit a negative direct Coombs test. Flow cytometry has been applied to detect RBC bound IgG with high accuracy, reproducibility and sensitivity. In this study 45 and 75 patients with AIHA and SLE, respectively were evaluated for RBC bound IgG by direct Coombs test and flow cytometry. Seventy-one percent (32/45) and 31% (23/75) of patients with AIHA and SLE respectively, had laboratory evidence of hemolysis. A positive flow cytometry, as defined by mean fluorescent intensity (MFI) values >0·21 and IgG molecules >28, was found in 4 of 32 (12·5%) and 4 of 23 (17·4%) patients with AIHA and SLE who had hemolysis with a negative direct Coombs test. There were very strong and strong correlations between the strength of direct Coombs test with MFI values and IgG molecules in patients with AIHA and SLE, respectively. Flow cytometry can be applied in the diagnosis of Coombs-negative hemolytic anaemia in patients with AIHA and SLE. © 2016 British Blood Transfusion Society.

  16. A Novel Quantitative Hemolytic Assay Coupled with Restriction Fragment Length Polymorphisms Analysis Enabled Early Diagnosis of Atypical Hemolytic Uremic Syndrome and Identified Unique Predisposing Mutations in Japan

    PubMed Central

    Yoshida, Yoko; Miyata, Toshiyuki; Matsumoto, Masanori; Shirotani-Ikejima, Hiroko; Uchida, Yumiko; Ohyama, Yoshifumi; Kokubo, Tetsuro; Fujimura, Yoshihiro

    2015-01-01

    For thrombotic microangiopathies (TMAs), the diagnosis of atypical hemolytic uremic syndrome (aHUS) is made by ruling out Shiga toxin-producing Escherichia coli (STEC)-associated HUS and ADAMTS13 activity-deficient thrombotic thrombocytopenic purpura (TTP), often using the exclusion criteria for secondary TMAs. Nowadays, assays for ADAMTS13 activity and evaluation for STEC infection can be performed within a few hours. However, a confident diagnosis of aHUS often requires comprehensive gene analysis of the alternative complement activation pathway, which usually takes at least several weeks. However, predisposing genetic abnormalities are only identified in approximately 70% of aHUS. To facilitate the diagnosis of complement-mediated aHUS, we describe a quantitative hemolytic assay using sheep red blood cells (RBCs) and human citrated plasma, spiked with or without a novel inhibitory anti-complement factor H (CFH) monoclonal antibody. Among 45 aHUS patients in Japan, 24% (11/45) had moderate-to-severe (≥50%) hemolysis, whereas the remaining 76% (34/45) patients had mild or no hemolysis (<50%). The former group is largely attributed to CFH-related abnormalities, and the latter group has C3-p.I1157T mutations (16/34), which were identified by restriction fragment length polymorphism (RFLP) analysis. Thus, a quantitative hemolytic assay coupled with RFLP analysis enabled the early diagnosis of complement-mediated aHUS in 60% (27/45) of patients in Japan within a week of presentation. We hypothesize that this novel quantitative hemolytic assay would be more useful in a Caucasian population, who may have a higher proportion of CFH mutations than Japanese patients. PMID:25951460

  17. Random uncertainty of photometric determination of hemolysis index on the Abbott Architect c16000 platform.

    PubMed

    Aloisio, Elena; Carnevale, Assunta; Pasqualetti, Sara; Birindelli, Sarah; Dolci, Alberto; Panteghini, Mauro

    2018-01-16

    Automatic photometric determination of the hemolysis index (HI) on serum and plasma samples is central to detect potential interferences of in vitro hemolysis on laboratory tests. When HI is above an established cut-off for interference, results may suffer from a significant bias and undermine clinical reliability of the test. Despite its undeniable importance for patient safety, the analytical performance of HI estimation is not usually checked in laboratories. Here we evaluated for the first time the random source of measurement uncertainty of HI determination on the two Abbott Architect c16000 platforms in use in our laboratory. From January 2016 to September 2017, we collected data from daily photometric determination of HI on a fresh-frozen serum pool with a predetermined HI value of ~100 (corresponding to ~1g/L of free hemoglobin). Monthly and cumulative CVs were calculated. During 21months, 442 and 451 measurements were performed on the two platforms, respectively. Monthly CVs ranged from 0.7% to 2.7% on c16000-1 and from 0.8% to 2.5% on c16000-2, with a between-platform cumulative CV of 1.82% (corresponding to an expanded uncertainty of 3.64%). Mean HI values on the two platforms were just slightly biased (101.3 vs. 103.1, 1.76%), but, due to the high precision of measurements, this difference assumed statistical significance (p<0.0001). Even though no quality specifications are available to date, our study shows that the HI measurement on Architect c16000 platform has nice reproducibility that could be considered in establishing the state of the art of the measurement. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Effect of red blood cell storage time on markers of hemolysis and inflammation in transfused very low birth weight infants.

    PubMed

    Kalhan, Tamara G; Bateman, David A; Bowker, Rakhee M; Hod, Eldad A; Kashyap, Sudha

    2017-12-01

    BackgroundProlonged storage of transfused red blood cells (RBCs) is associated with hemolysis in healthy adults and inflammation in animal models. We aimed to determine whether storage duration affects markers of hemolysis (e.g., serum bilirubin, iron, and non-transferrin-bound iron (NTBI)) and inflammation (e.g., interleukin (IL)-8 and monocyte chemoattractant protein (MCP)-1) in transfused very low birth weight (VLBW) infants.MethodsBlood samples from 23 independent transfusion events were collected by heel stick before and 2-6 h after transfusion.ResultsSerum iron, total bilirubin, NTBI, and MCP-1 levels were significantly increased after transfusion of RBCs (P<0.05 for each comparison). The storage age of transfused RBCs positively correlated with increases in NTBI following transfusion (P<0.001; R 2 =0.44). No associations between storage duration and changes in the other analytes were observed.ConclusionTransfusion of RBCs into VLBW infants is associated with increased markers of hemolysis and the inflammatory chemokine MCP-1. RBC-storage duration only correlated with increases in NTBI levels following transfusion. NTBI was only observed in healthy adults following 35 days of storage; however, this study suggests that VLBW infants are potentially more susceptible to produce this pathological form of iron, with increased levels observed after transfusion of only 20-day-old RBCs.

  19. Systematic Assessment of the Hemolysis Index: Pros and Cons.

    PubMed

    Lippi, Giuseppe

    2015-01-01

    Preanalytical quality is as important as the analytical and postanalytical quality in laboratory diagnostics. After decades of visual inspection to establish whether or not a diagnostic sample may be suitable for testing, automated assessment of hemolysis index (HI) has now become available in a large number of laboratory analyzers. Although most national and international guidelines support systematic assessment of sample quality via HI, there is widespread perception that this indication has not been thoughtfully acknowledged. Potential explanations include concern of increased specimen rejection rate, poor harmonization of analytical techniques, lack of standardized units of measure, differences in instrument-specific cutoff, negative impact on throughput, organization and laboratory economics, and lack of a reliable quality control system. Many of these concerns have been addressed. Evidence now supports automated HI in improving quality and patient safety. These will be discussed. © 2015 Elsevier Inc. All rights reserved.

  20. Antibacterial potential of phytochemicals alone or in combination with antimicrobials against fish pathogenic bacteria.

    PubMed

    Bandeira Junior, G; Sutili, F J; Gressler, L T; Ely, V L; Silveira, B P; Tasca, C; Reghelin, M; Matter, L B; Vargas, A P C; Baldisserotto, B

    2018-05-09

    This study investigated the antibacterial activity of five phytochemicals (carvacrol, citral, eugenol, linalool, and thymol) alone or in combination with florfenicol or oxytetracycline against bacteria isolated from silver catfish (Rhamdia quelen). We also analyzed the potential of these compounds to inhibit biofilm formation and hemolysis caused by the bacteria. Bacteria were tested with antimicrobials to calculate the multiple antibiotic resistance (MAR). The checkerboard assay was used to evaluate a putative synergy between five phytochemicals and antimicrobials against the strains isolated. The biofilm formation inhibition assay was performed with phytochemicals and antimicrobials, and the hemolysis inhibition assay was performed with the phytochemicals. Carvacrol, eugenol and thymol were the most effective phytochemicals. Three combinations (linalool with florfenicol or oxytetracycline against Aeromonas hydrophila and citral with oxytetracycline against Citrobacter freundii) demonstrated synergy in the checkerboard assay. All phytochemicals inhibited biofilm formation and hemolysis activity. The tested phytochemicals showed satisfactory activity against fish pathogenic bacteria. The phytochemicals did not present antagonistic interactions with the antimicrobials, allowing their combined use, which may contribute to a decrease in the use of conventional drugs and their residues in aquatic environment. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. In vitro lysis and acute transfusion reactions with hemolysis caused by inappropriate storage of canine red blood cell products.

    PubMed

    Patterson, J; Rousseau, A; Kessler, R J; Giger, U

    2011-01-01

    Transfusion of red blood cell (RBC) products carries considerable risk for adverse reactions, including life-threatening hemolytic reactions. To report the occurrence and investigation of life-threatening acute transfusion reactions with hemolysis in dogs likely related to inappropriate blood product storage. Four dogs with acute transfusion reactions and other recipients of blood products. Medical records were reviewed from 4 dogs with suspected acute hemolytic transfusion reactions after receiving RBC products at a veterinary clinic over a 1-month period. Medical records of other animals receiving blood products in the same time period also were reviewed. Blood compatibility and product quality were assessed, subsequent transfusions were closely monitored, and products were diligently audited. During or immediately after RBC product transfusion, 4 dogs developed hemolysis, hemoglobinuria, or both. Two dogs died and 1 was euthanized because of progressive clinical signs compatible with an acute hemolytic transfusion reaction. Blood type and blood compatibility were confirmed. RBC units from 2 blood banks were found to be hemolyzed after storage in the clinic's refrigerator; no bacterial contamination was identified. After obtaining a new refrigerator dedicated to blood product storage, the problem of hemolyzed units and acute transfusion reactions with hemolysis completely resolved. Acute life-threatening transfusion reactions can be caused by inappropriate storage of RBC products. In addition to infectious disease screening and ensuring blood-type compatibility, quality assessment of blood products, appropriate collection, processing, and storage techniques as well as recipient monitoring are critical to provide safe, effective transfusions. Copyright © 2011 by the American College of Veterinary Internal Medicine.

  2. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    PubMed

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  3. A bispecific antibody based assay shows potential for detecting tuberculosis in resource constrained laboratory settings.

    PubMed

    Sarkar, Susmita; Tang, Xinli L; Das, Dipankar; Spencer, John S; Lowary, Todd L; Suresh, Mavanur R

    2012-01-01

    The re-emergence of tuberculosis (TB) as a global public health threat highlights the necessity of rapid, simple and inexpensive point-of-care detection of the disease. Early diagnosis of TB is vital not only for preventing the spread of the disease but also for timely initiation of treatment. The later in turn will reduce the possible emergence of multi-drug resistant strains of Mycobacterium tuberculosis. Lipoarabinomannan (LAM) is an important non-protein antigen of the bacterial cell wall, which is found to be present in different body fluids of infected patients including blood, urine and sputum. We have developed a bispecific monoclonal antibody with predetermined specificities towards the LAM antigen and a reporter molecule horseradish peroxidase (HRPO). The developed antibody was subsequently used to design a simple low cost immunoswab based assay to detect LAM antigen. The limit of detection for spiked synthetic LAM was found to be 5.0 ng/ml (bovine urine), 0.5 ng/ml (rabbit serum) and 0.005 ng/ml (saline) and that for bacterial LAM from M. tuberculosis H37Rv was found to be 0.5 ng/ml (rabbit serum). The assay was evaluated with 21 stored clinical serum samples (14 were positive and 7 were negative in terms of anti-LAM titer). In addition, all 14 positive samples were culture positive. The assay showed 100% specificity and 64% sensitivity (95% confidence interval). In addition to good specificity, the end point could be read visually within two hours of sample collection. The reported assay might be used as a rapid tool for detecting TB in resource constrained laboratory settings.

  4. Continuous-flow automation and hemolysis index: a crucial combination.

    PubMed

    Lippi, Giuseppe; Plebani, Mario

    2013-04-01

    A paradigm shift has occurred in the role and organization of laboratory diagnostics over the past decades, wherein consolidation or networking of small laboratories into larger factories and point-of-care testing have simultaneously evolved and now seem to favorably coexist. There is now evidence, however, that the growing implementation of continuous-flow automation, especially in closed systems, has not eased the identification of hemolyzed specimens since the integration of preanalytical and analytical workstations would hide them from visual scrutiny, with an inherent risk that unreliable test results may be released to the stakeholders. Along with other technical breakthroughs, the new generation of laboratory instrumentation is increasingly equipped with systems that can systematically and automatically be tested for a broad series of interferences, the so-called serum indices, which also include the hemolysis index. The routine implementation of these technical tools in clinical laboratories equipped with continuous-flow automation carries several advantages and some drawbacks that are discussed in this article.

  5. Nitric Oxide-Dependent Endothelial Dysfunction and Reduced Arginine Bioavailability in Plasmodium vivax Malaria but No Greater Increase in Intravascular Hemolysis in Severe Disease.

    PubMed

    Barber, Bridget E; William, Timothy; Grigg, Matthew J; Piera, Kim A; Chen, Youwei; Wang, Hao; Weinberg, J Brice; Yeo, Tsin W; Anstey, Nicholas M

    2016-11-15

     Pathogenesis of severe Plasmodium vivax malaria is poorly understood. Endothelial dysfunction and reduced nitric oxide (NO) bioavailability characterize severe falciparum malaria, but have not been assessed in severe vivax malaria.  In patients with severe vivax malaria (n = 9), patients with nonsevere vivax malaria (n = 58), and healthy controls (n = 79), we measured NO-dependent endothelial function by using reactive hyperemia-peripheral arterial tonometry (RH-PAT) and assessed associations with arginine, asymmetric dimethylarginine (ADMA), and hemolysis.  The L-arginine level and the L-arginine to ADMA ratio (a measure of L-arginine bioavailability) were reduced in patients with severe vivax malaria and those with nonsevere vivax malaria, compared with healthy controls (median L-arginine level, 65, 66, and 98 µmol/mL, respectively [P = .0001]; median L-arginine to ADMA ratio, 115, 125, and 187, respectively [P = .0001]). Endothelial function was impaired in proportion to disease severity (median RH-PAT index, 1.49, 1.73, and 1.97 in patients with severe vivax malaria, those with nonsevere vivax malaria, and healthy controls, respectively; P = .018) and was associated with the L-arginine to ADMA ratio. While the posttreatment fall in hemoglobin level was greater in severe vivax malaria as compared to nonsevere vivax malaria (2.5 vs 1 g/dL; P = .0001), markers of intravascular hemolysis were not higher in severe disease.  Endothelial function is impaired in nonsevere and severe vivax malaria, is associated with reduced L-arginine bioavailability, and may contribute to microvascular pathogenesis. Severe disease appears to be more associated with extravascular hemolysis than with intravascular hemolysis. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  6. Risks of Hemolysis in Glucose-6-Phosphate Dehydrogenase Deficient Infants Exposed to Chlorproguanil-Dapsone, Mefloquine and Sulfadoxine-Pyrimethamine as Part of Intermittent Presumptive Treatment of Malaria in Infants.

    PubMed

    Poirot, Eugenie; Vittinghoff, Eric; Ishengoma, Deus; Alifrangis, Michael; Carneiro, Ilona; Hashim, Ramadhan; Baraka, Vito; Mosha, Jacklin; Gesase, Samwel; Chandramohan, Daniel; Gosling, Roland

    2015-01-01

    Chlorproguanil-dapsone (CD) has been linked to hemolysis in symptomatic glucose-6-phosphate dehydrogenase deficient (G6PDd) children. Few studies have explored the effects of G6PD status on hemolysis in children treated with Intermittent Preventive Treatment in infants (IPTi) antimalarial regimens. We sought to examine the joint effects of G6PD status and IPTi antimalarial treatment on incidence of hemolysis in asymptomatic children treated with CD, sulfadoxine-pyrimethamine (SP), and mefloquine (MQ). A secondary analysis of data from a double-blind, placebo-controlled trial of IPTi was conducted. Hemoglobin (Hb) measurements were made at IPTi doses, regular follow-up and emergency visits. G6PD genotype was determined at 9 months looking for SNPs for the A- genotype at coding position 202. Multivariable linear and logistic regression models were used to examine hemolysis among children with valid G6PD genotyping results. Hemolysis was defined as the absolute change in Hb or as any post-dose Hb <8 g/dL. These outcomes were assessed using either a single follow-up Hb on day 7 after an IPTi dose or Hb obtained 1 to 14 or 28 days after each IPTi dose. Relative to placebo, CD reduced Hb by approximately 0.5 g/dL at day 7 and within 14 days of an IPTi dose, and by 0.2 g/dL within 28 days. Adjusted declines in the CD group were larger than in the MQ and SP groups. At day 7, homo-/hemizygous genotype was associated with higher odds of Hb <8 g/dL (adjusted odds ratio = 6.7, 95% CI 1.7 to 27.0) and greater absolute reductions in Hb (-0.6 g/dL, 95% CI -1.1 to 0.003). There was no evidence to suggest increased reductions in Hb among homo-/hemizygous children treated with CD compared to placebo, SP or MQ. While treatment with CD demonstrated greater reductions in Hb at 7 and 14 days after an IPTi dose compared to both SP and MQ, there was no evidence that G6PD deficiency exacerbated the adverse effects of CD, despite evidence for higher hemolysis risk among G6PDd infants.

  7. Blood cell oxidative stress precedes hemolysis in whole blood-liver slice co-cultures of rat, dog, and human tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vickers, Alison E.M., E-mail: vickers_alison@allergan.co; Sinclair, John R.; Fisher, Robyn L.

    A novel in vitro model to investigate time-dependent and concentration-dependent responses in blood cells and hemolytic events is studied for rat, dog, and human tissues. Whole blood is co-cultured with a precision-cut liver slice. Methimazole (MMI) was selected as a reference compound, since metabolism of its imidazole thione moiety is linked with hematologic disorders and hepatotoxicity. An oxidative stress response occurred in all three species, marked by a decline in blood GSH levels by 24 h that progressed, and preceded hemolysis, which occurred at high MMI concentrations in the presence of a liver slice with rat (>= 1000 muM atmore » 48 h) and human tissues (>= 1000 muM at 48 h, >= 750 muM at 72 h) but not dog. Human blood-only cultures exhibited a decline of GSH levels but minimal to no hemolysis. The up-regulation of liver genes for heme degradation (Hmox1 and Prdx1), iron cellular transport (Slc40a1), and GSH synthesis and utilization (mGST1 and Gclc) were early markers of the oxidative stress response. The up-regulation of the Kupffer cell lectin Lgals3 gene expression indicated a response to damaged red blood cells, and Hp (haptoglobin) up-regulation is indicative of increased hemoglobin uptake. Up-regulation of liver IL-6 and IL-8 gene expression suggested an activation of an inflammatory response by liver endothelial cells. In summary, MMI exposure led to an oxidative stress response in blood cells, and an up-regulation of liver genes involved with oxidative stress and heme homeostasis, which was clearly separate and preceded frank hemolysis.« less

  8. Efficacy of simple short-term in vitro assays for predicting the potential of metal oxide nanoparticles to cause pulmonary inflammation.

    PubMed

    Lu, Senlin; Duffin, Rodger; Poland, Craig; Daly, Paul; Murphy, Fiona; Drost, Ellen; Macnee, William; Stone, Vicki; Donaldson, Ken

    2009-02-01

    There has been concern regarding risks from inhalation exposure to nanoparticles (NPs). The large number of particles requiring testing means that alternative approaches to animal testing are needed. We set out to determine whether short-term in vitro assays that assess intrinsic oxidative stress potential and membrane-damaging potency of a panel of metal oxide NPs can be used to predict their inflammogenic potency. For a panel of metal oxide NPs, we investigated intrinsic free radical generation, oxidative activity in an extracellular environment, cytotoxicity to lung epithelial cells, hemolysis, and inflammation potency in rat lungs. All exposures were carried out at equal surface area doses. Only nickel oxide (NiO) and alumina 2 caused significant lung inflammation when instilled into rat lungs at equal surface area, suggesting that these two had extra surface reactivity. We observed significant free radical generation with 4 of 13 metal oxides, only one of which was inflammogenic. Only 3 of 13 were significantly hemolytic, two of which were inflammogenic. Potency in generating free radicals in vitro did not predict inflammation, whereas alumina 2 had no free radical activity but was inflammogenic. The hemolysis assay was correct in predicting the proinflammatory potential of 12 of 13 of the particles examined. Using a battery of simple in vitro tests, it is possible to predict the inflammogenicity of metal oxide NPs, although some false-positive results are likely. More research using a larger panel is needed to confirm the efficacy and generality of this approach for metal oxide NPs.

  9. Eugenol prevents amyloid formation of proteins and inhibits amyloid-induced hemolysis

    NASA Astrophysics Data System (ADS)

    Dubey, Kriti; Anand, Bibin G.; Shekhawat, Dolat Singh; Kar, Karunakar

    2017-02-01

    Eugenol has attracted considerable attention because of its potential for many pharmaceutical applications including anti-inflammatory, anti-tumorigenic and anti-oxidant properties. Here, we have investigated the effect of eugenol on amyloid formation of selected globular proteins. We find that both spontaneous and seed-induced aggregation processes of insulin and serum albumin (BSA) are significantly suppressed in the presence of eugenol. Isothermal titration calorimetric data predict a single binding site for eugenol-insulin complex confirming the affinity of eugenol for native soluble insulin species. We also find that eugenol suppresses amyloid-induced hemolysis. Our findings reveal the inherent ability of eugenol to stabilize native proteins and to delay the conversion of protein species of native conformation into β-sheet assembled mature fibrils, which seems to be crucial for its inhibitory effect.

  10. Biomedical research of novel biodegradable copoly(amino acid)s based on 6-aminocaproic acid and L-proline.

    PubMed

    Zhang, Weipeng; Shao, Jianmin

    2010-08-01

    The biomedical properties of novel biodegradable copoly(amino acid)s based on 6-aminocaproic acid and L-proline were analyzed in this article. The cytotoxicity of the copolymer films was tested in vitro using human embryonic kidney (HEK) 293 cells. The cell proliferation, cell cycle, cell apoptosis, and hemolysis of the polymers were also investigated. No significant cytotoxic response was detected statistically by cytotoxicity assay, and the results of cell apoptosis and cell cycle showed that there were no statistically significant differences in them. Generally, the cells spread and grew well on polymer film. Meanwhile, the extent of hemolysis on the polymers was acceptable. Evaluation of cytotoxicity by cell cycle and apoptosis as a supplementary assay is correspondingly discussed in this article. (c) 2010 Wiley Periodicals, Inc.

  11. Severe Hemolysis in a Patient With Erythrocytosis During Coupled Plasma Filtration Adsorption Therapy Was Prevented by Changing From Membrane-Based Technique to a Centrifuge-Based One.

    PubMed

    Fan, Rong; Wu, Buyun; Kong, Ling; Gong, Dehua

    2016-01-01

    Coupled plasma filtration adsorption (CPFA) usually adopts membrane to separate plasma from blood. Here, we reported a case with erythrocytosis experienced severe hemolysis and membrane rupture during CPFA, which was avoided by changing from membrane-based technique to a centrifuge-based one. A 66-year-old man was to receive CPFA for severe hyperbilirubinemia (total bilirubin 922 μmol/L, direct bilirubin 638 μmol/L) caused by obstruction of biliary tract. He had erythrocytosis (hemoglobin 230 g/L, hematocrit 0.634) for years because of untreated tetralogy of Fallot. Severe hemolysis and membrane rupture occurred immediately after blood entering into the plasma separator even at a low flow rate (50 mL/min) and persisted after changing a new separator. Finally, centrifugal plasma separation technique was used for CPFA in this patient, and no hemolysis occurred. After 3 sessions of CPFA, total bilirubin level decreased to 199 μmol/L with an average decline by 35% per session. Thereafter, the patient received endoscopic biliary stent implantation, and total bilirubin level returned to nearly normal. Therefore, centrifugal-based plasma separation can also be used in CPFA and may be superior to a membrane-based one in patients with hyperviscosity.

  12. Erythrocytic ferroportin reduces intracellular iron accumulation, hemolysis, and malaria risk.

    PubMed

    Zhang, De-Liang; Wu, Jian; Shah, Binal N; Greutélaers, Katja C; Ghosh, Manik C; Ollivierre, Hayden; Su, Xin-Zhuan; Thuma, Philip E; Bedu-Addo, George; Mockenhaupt, Frank P; Gordeuk, Victor R; Rouault, Tracey A

    2018-03-30

    Malaria parasites invade red blood cells (RBCs), consume copious amounts of hemoglobin, and severely disrupt iron regulation in humans. Anemia often accompanies malaria disease; however, iron supplementation therapy inexplicably exacerbates malarial infections. Here we found that the iron exporter ferroportin (FPN) was highly abundant in RBCs, and iron supplementation suppressed its activity. Conditional deletion of the Fpn gene in erythroid cells resulted in accumulation of excess intracellular iron, cellular damage, hemolysis, and increased fatality in malaria-infected mice. In humans, a prevalent FPN mutation, Q248H (glutamine to histidine at position 248), prevented hepcidin-induced degradation of FPN and protected against severe malaria disease. FPN Q248H appears to have been positively selected in African populations in response to the impact of malaria disease. Thus, FPN protects RBCs against oxidative stress and malaria infection. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  13. Deformable cells in confined geometries: From hemolysis to hydrodynamic interactions

    NASA Astrophysics Data System (ADS)

    Abkarian, Manouk; Faivre, Magalie; Stone, Howard A.

    2004-11-01

    Recent developments in microfluidics allow a wide range of possibilities for studying cellular-scale hydrodynamics. Here we use microfluidic technology to address several open questions in the blood flow literature where cell deformation and hydrodynamic interactions are significant. In particular, we investigate the pressure-driven flow of a dilute suspension in a channel and characterize the transition from steady axisymmetric cell shapes (for which numerical calculations exist) to asymmetric, highly extended shapes, which are precursors to hemolysis (i.e. destruction of the cell). In addition, we examine the influence of geometry on hydrodynamic interactions of deformable cells by contrasting one-dimensional motion of a train of particles in a channel with two-dimensional motions in a Hele-Shaw cell. This study can help to understand flow of cells in microcirculation from the unidirectional flow in capillaries to the two-dimensional flow in the lung alveoli and provides the basic steps to understand certain aspects of microcirculatory deseases like sickle cell anemia for example.

  14. A urine midmolecule osteocalcin assay shows higher discriminatory power than a serum midmolecule osteocalcin assay during short-term alendronate treatment of osteoporotic patients.

    PubMed

    Srivastava, A K; Mohan, S; Singer, F R; Baylink, D J

    2002-07-01

    We isolated and characterized a peptide fragment corresponding to amino acid sequence 14-28 of human osteocalcin in urine from Paget's disease, and developed a polyclonal antibody reactive to this peptide in urine. We used this antibody to measure urinary fragments of osteocalcin and compared to efficacy of the urinary osteocalcin assay with a serum osteocalcin (sOC) assay (ELISA-Osteo, Cis-Bio International) to monitor the short-term changes in bone turnover in response to alendronate treatment. The synthetic peptide-based urinary osteocalcin (uOC) radioimmunoassay (RIA) showed an analytical sensitivity of 6.25 ng/mL, standard curve range of 3.12-400 ng/mL, and mean intra- (n = 20) and interassay (n = 30) coefficient of variation (CV) of <15%. Urine osteocalcin concentrations in postmenopausal osteoporotic patients were approximately 90% higher than in normal premenopausal controls. Series of 24 h urine and matched serum samples were collected at baseline, 30 days, and 90 days after treatment of postmenopausal osteoporotic patients with daily dose of 10 mg alendronate. We measured urinary osteocalcin (uOc) levels and urinary N-telopeptide (uNTx, Ostex) in urine samples and serum N-telopeptide (sNTx), C-telopeptide (sCTx, Osteometer), serum osteocalcin (sOC) as well as bone-specific alkaline phosphatase (sALP) (Alkphose-B, Metra Biosystems) in serum samples. The percent change data obtained between baseline and 30 days (n = 18) posttreatment suggested a rapid decline in uOC concentration (-27%, p < 0.01) in response to alendronate treatment, as compared with a marginal and nonsignificant decrease in sOC (-7.2%, p = 0.417) or sALP (-3.4%, p = 0.689), two specific markers of bone formation. As expected, due to the coupling of bone formation and bone resorption, the concentration of all markers showed a 30%-45% decline compared with baseline values after 90 days (n = 16) of treatment. Correlation of markers after a 30 day treatment with alendronate revealed a higher

  15. Controlled lecithin release from a hierarchical architecture on blood-contacting surface to reduce hemolysis of stored red blood cells.

    PubMed

    Shi, Qiang; Fan, Qunfu; Ye, Wei; Hou, Jianwen; Wong, Shing-Chung; Xu, Xiaodong; Yin, Jinghua

    2014-06-25

    Hemolysis of red blood cells (RBCs) caused by implant devices in vivo and nonpolyvinyl chloride containers for RBC preservation in vitro has recently gained much attention. To develop blood-contacting biomaterials with long-term antihemolysis capability, we present a facile method to construct a hydrophilic, 3D hierarchical architecture on the surface of styrene-b-(ethylene-co-butylene)-b-styrene elastomer (SEBS) with poly(ethylene oxide) (PEO)/lecithin nano/microfibers. The strategy is based on electrospinning of PEO/lecithin fibers onto the surface of poly [poly(ethylene glycol) methyl ether methacrylate] [P(PEGMEMA)]-modified SEBS, which renders SEBS suitable for RBC storage in vitro. We demonstrate that the constructed 3D architecture is composed of hydrophilic micro- and nanofibers, which transforms to hydrogel networks immediately in blood; the controlled release of lecithin is achieved by gradual dissolution of PEO/lecithin hydrogels, and the interaction of lecithin with RBCs maintains the membrane flexibility and normal RBC shape. Thus, the blood-contacting surface reduces both mechanical and oxidative damage to RBC membranes, resulting in low hemolysis of preserved RBCs. This work not only paves new way to fabricate high hemocompatible biomaterials for RBC storage in vitro, but provides basic principles to design and develop antihemolysis biomaterials for implantation in vivo.

  16. Analytical validation of soluble fms-like tyrosine and placental growth factor assays on B·R·A·H·M·S KRYPTOR Compact Plus automated immunoassay platform.

    PubMed

    Chan, Siaw Li; Rana, Sarosh; Chinthala, Sireesha; Salahuddin, Saira; Yeo, Kiang-Teck J

    2018-01-01

    Preeclampsia is one of the leading hypertensive disorders of pregnancy. Angiogenic biomarkers such as anti-angiogenic factor soluble fms-like tyrosine kinase 1 (sFlt1) and pro-angiogenic factor placental growth factor (PlGF) are involved in the pathophysiology of preeclampsia. The aim of this study is to validate the analytical performance of sFlt1 and PlGF on the B·R·A·H·M·S KRYPTOR Compact Plus (ThermoFisher Scientific). We examined K 2 -EDTA plasma samples from 50 patients on B·R·A·H·M·S KRYPTOR Compact Plus, an automated immunoassay platform. QC materials were used to assess intra- and inter-precision of the assay. Lower limit of quantitation and interference studies were determined using pooled patient plasma. The sFlt1 and PlGF assays demonstrated an analytical measuring range of 90-69,000 pg/mL and 11-7000 pg/mL, respectively (r 2  > 0.99). Lower limit of quantitation (20% CV) was interpolated to be 35 pg/mL for sFlt1 and 10 pg/mL for PlGF. Total precision for both assay displayed CVs of <10%. Interference studies showed that both assays were not significantly affected by hemolysis up to an H-index of 1100 for sFlt1 and 300 for PlGF; L- and I-index of 800 and 80 respectively for both assays. The Passing-Bablok regression analysis for sFlt1/PlGF yielded an equation of y = 1.05x + 0.02, and the Bland Altman analysis showed an average bias of 0.84. Plasma levels of sFlt1 and PlGF measured on the B·R·A·H·M·S KRYPTOR Compact Plus platform demonstrate excellent analytical performance and are acceptable as clinical grade assays. Copyright © 2018 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

  17. Acceleration of thrombosis and hemolysis by fibrinolysis inhibiting factor and suppression by Ia antigen expressed on T cells in partially hepatectomized Lewis rats.

    PubMed

    Nakatsuji, T

    1996-10-01

    Partial hepatectomy (PH) of a left lateral lobe was performed on 45 Lewis rats 6.5-8.0 weeks old. Splenectomy, the injection of a fibrinolysis inhibiting (F1) factor (Gly-Pro-Arg-Pro) and both treatments were combined with the PH in 10, 11 and 9 rats, respectively. Among them, 4 males became weak with marked atrophic thymus before the 46th day after PH. All these males had massive pulmonary necrosis accompanied by platelet-rich emboli. Erythrocyte rosette formation was recognized in the mesenteric lymph nodes (MLN) of all 4 rats. The rosette erythrocytes reacted to anti-macrophage antibodies. FI factor-induced acute immune hemolysis occurred 5-9 days after PH in the 2 of the FI factor-injected and splenectomized males. Mildly to moderately atrophic thymuses were found in almost all the rats followed for 156-177 days after PH. T lymphocytes with cytoplasmic dense polysomes and desquamating endothelial cells with phagocytic erythrocytes were observed in the thymic electron micrograph of the FI factor-injected female. Positive D-D dimers were measured in the plasma of 7 rats. Increased peripheral reticulocytes (7.0 +/- 0.4%) were recognized in the males 156 days after single PH but not in the females. Ten of the 24 females and 3 of the 16 males showed an increase of peripheral Ia+ T cells to 20-30%. As well as acute pulmonary emboli, autoimmune hemolysis was induced more actively after PH in the males with CD5+ T cells that expressed the Ia antigen weakly.

  18. Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory.

    PubMed

    Dhungana, Neha; Morris, Cory; Krasowski, Matthew D

    2017-08-01

    The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR). Retrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6%) exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5%) exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1%) of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods. Vanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations.

  19. Maternal cautopyreiophagia as a rare cause of neonatal hemolysis: a case report.

    PubMed

    Bernardo, Erika O; Matos, Renée I; Dawood, Taslim; Whiteway, Susan L

    2015-03-01

    Hyperbilirubinemia in the first 24 hours of life in a newborn is pathologic, necessitating additional evaluation. We report the first case of hemolysis and subsequent hyperbilirubinemia in an otherwise normal term neonate resulting from oxidative stress in the form of maternal cautopyreiophagia: the ingestion of burnt matchstick heads. During the third trimester of pregnancy, the infant's mother consumed more than 300 burnt matchstick heads weekly for 4 weeks. Matches contain potassium chlorate, a powerful oxidant that when ingested can ultimately lead to the destruction of erythrocytes, disseminated intravascular coagulation, kidney injury, or death. The infant's bilirubin rose as high as 17 mg/dL at 22 hours of life; however, the infant did well with a brief course of phototherapy. This case highlights the importance of prenatal questioning about maternal ingestion of potentially oxidative substances and assessing the possible risk for the infant. published in the public domain by the American Academy of Pediatrics.

  20. Normalization of elevated cardiac, kidney, and hemolysis plasma markers within 48 h in Mexican Tarahumara runners following a 78 km race at moderate altitude.

    PubMed

    Christensen, Dirk L; Espino, Diana; Infante-Ramírez, Rocío; Brage, Soren; Terzic, Dijana; Goetze, Jens P; Kjaergaard, Jesper

    2014-01-01

    The aim of this study was to examine to what extent extreme endurance exercise results in changes of plasma markers associated with cardiac and renal damage, as well as hemolysis in male, Mexican Tarahumara runners. Ten Tarahumara runners (mean (sd) age of 38 (12) years) participated in a 78 km race in Chihuahua, Mexico at 2,400 m above sea level. Cardiac, kidney, and hematology plasma markers were measured pre-race and <5 min, 1 h, 3 h, 6 h, 24 h, and 48 h post-race. Anthropometry, blood pressure, pulse rate, electrocardiography, HbA1c, hemoglobin and VO2max (estimated from heart rate following step test) were assessed pre-race, while physical activity energy expenditure and intensity were estimated during the race, and oxygen partial pressure saturation (SpO2 ) <30 min post-race. Estimated mean VO2max was 48 (9) mLO2 min(-1) kg(-1) and relative intensity during the race was 68 (11)%VO2 max. Mean SpO2 was 92 (3)% <30 min post-race. Plasma concentrations of especially total creatine kinase, creatine kinase-MB isoform, and haptoglobin changed significantly from pre-race values (P < 0.001) up to 24 h post-race, but had returned to pre-race values after 48 h. The plasma concentrations of mid-regional proatrial natiuretic peptide and copeptin returned to pre-race concentrations after 1 and 6 h, respectively. Altered cardiac, renal, and hemolysis plasma markers were normalized after 48 h following 78 km of running, suggesting that the impact of exercise-induced cardiac and kidney damage as well as hemolysis in the Mexican Tarahumara is low. © 2014 Wiley Periodicals, Inc.

  1. Effect of chlorphenesin on localized hemolysis in gel assay.

    PubMed

    Fukui, G M; Berger, F M; Chandlee, G C; Goldenbaum, E G

    1968-10-01

    Chlorphenesin, a simple glycerol ether, when added to Jerne plates greatly reduced the number of hemolytic plaques. This effect appeared to be related to dose, and was clearly demonstrable with antibody-forming spleen cells from mice that had been immunized either with sheep red blood cells or with penicillin G conjugated with Keyhole limpet hemocyanin. Chlorphenesin did not affect the antigen, destroy complement, or interfere with the interaction of complement and the antigen-antibody complexes. Incubation of spleen cell suspensions with chlorphenesin prior to plating was more effective in reducing the number of plaques than was addition of the substance to the plates. It may act by reducing the ability of antibodies to react with antigens or by affecting the release of antibodies from the spleen cells.

  2. Effect of Chlorphenesin on Localized Hemolysis in Gel Assay

    PubMed Central

    Fukui, G. M.; Berger, F. M.; Chandlee, G. C.; Goldenbaum, E. G.

    1968-01-01

    Chlorphenesin, a simple glycerol ether, when added to Jerne plates greatly reduced the number of hemolytic plaques. This effect appeared to be related to dose, and was clearly demonstrable with antibody-forming spleen cells from mice that had been immunized either with sheep red blood cells or with penicillin G conjugated with Keyhole limpet hemocyanin. Chlorphenesin did not affect the antigen, destroy complement, or interfere with the interaction of complement and the antigen-antibody complexes. Incubation of spleen cell suspensions with chlorphenesin prior to plating was more effective in reducing the number of plaques than was addition of the substance to the plates. It may act by reducing the ability of antibodies to react with antigens or by affecting the release of antibodies from the spleen cells. PMID:5685993

  3. Assessing matrix, interferences and comparability between the Abbott Diagnostics and the Beckman Coulter high-sensitivity cardiac troponin I assays.

    PubMed

    Kavsak, Peter A; Malinowski, Paul; Roy, Chantele; Clark, Lorna; Lamers, Shana

    2018-03-13

    Analytical evaluation of high-sensitivity cardiac troponin (hs-cTn) assays, with particular attention to imprecision, interferences and matrix effects, at normal cTn concentrations, is of utmost importance as many different clinical algorithms use concentration cutoffs <10 ng/L for decision-making. The objective for the present analytical study was to compare the new Beckman Coulter hs-cTnI assay (Access hsTnI) to Abbott's hs-cTnI assay in different matrices and for different interferences, with a focus on concentrations <10 ng/L. The limit of blank (LoB) and the limit of detection (LoD) were determined in different matrices for the Beckman hs-cTnI assay. Passing-Bablok regression and difference plots were determined for 200 matched lithium heparin and EDTA plasma samples for the Beckman assay and 200 lithium heparin samples for the Abbott assay. Both EDTA and heparin plasma samples were also evaluated for stability under refrigerated conditions, for endogenous alkaline phosphatase interference and for hemolysis and icterus. The Beckman hs-cTnI assay LoB was 0.5 ng/L with the following range of LoDs=0.8-1.2 ng/L, with EDTA plasma yielding lower concentrations as compared to lithium heparin plasma (mean difference=-14.9%; 95% CI=-16.9 to 12.9). Below 10 ng/L, lithium heparin cTnI results from the Beckman assay were on average 1.1 ng/L (95% CI=0.7 to 1.5) higher than the Abbott results, with no difference between the methods when using EDTA plasma (mean difference =-0.1 ng/L; 95% CI=-0.3 to 0.2). Low cTnI concentrations were less effected by interferences in EDTA plasma. The Access hsTnI method can reliably detect normal cTnI concentrations with both lithium heparin and EDTA plasma being suitable matrices.

  4. Larval development assays reveal the presence of sub-populations showing high- and low-level resistance in a monepantel (Zolvix®)-resistant isolate of Haemonchus contortus.

    PubMed

    Raza, Ali; Lamb, Jane; Chambers, Michael; Hunt, Peter W; Kotze, Andrew C

    2016-04-15

    Resistance to the amino-acetonitrile derivative monepantel has been reported in several species of gastrointestinal nematodes over recent years. We were interested in the use of in vitro assays with free-living worm life-stages to detect resistance to this drug. We therefore used larval development and larval migration assays to examine dose response relationships for the drug against two susceptible and one resistant isolate of Haemonchus contortus. The resistant isolate was established by laboratory propagation of the survivors of a field treatment with Zolvix(®) that had originally resulted in a drug efficacy of over 99%. Drug efficacy against this field-derived laboratory-propagated resistant isolate in vivo was approximately 15%. The larval development assay proved able to discriminate between the susceptible and resistant isolates, with larvae of the resistant isolate showing an ability to develop at higher drug concentrations than the two susceptible isolates. The resistant isolate showed the presence of two distinct subpopulations, separated by a plateau in the dose-response curve. Sub-population 1 (approximately 40% of the total population) showed a low level of resistance with an IC50 increased approximately 7-fold compared to the baseline susceptible isolate, while sub-population 2 (the remaining 60% of the total population) showed an IC50 increased over 1000-fold compared to the baseline susceptible isolate. This level of resistance is unusually high for any gastrointestinal nematode species in drug dose-response in vitro assays. In contrast, the migration assay could not discriminate between the three isolates, with migration not reduced to zero at any of the drug concentrations tested. This study demonstrates that a larval development assay is able to detect resistance to monepantel in H. contortus, and that resistance can exist in two distinct forms. This suggests that at least two separate monepantel resistance mechanisms are acting within the worm

  5. Diagnosis of preeclampsia with soluble Fms-like tyrosine kinase 1/placental growth factor ratio: an inter-assay comparison.

    PubMed

    Andersen, Louise Bjørkholt; Frederiksen-Møller, Britta; Work Havelund, Kathrine; Dechend, Ralf; Jørgensen, Jan Stener; Jensen, Boye L; Nielsen, Jan; Lykkedegn, Sine; Barington, Torben; Christesen, Henrik Thybo

    2015-02-01

    The angiogenic factor ratio soluble Fms-kinase 1 (sFlt-1)/placental growth factor (PlGF) is a novel diagnostic tool for preeclampsia. We compared the efficacy of the KRYPTOR (BRAHMS) automated assays for sFlt-1 and PlGF with the Elecsys (Roche) assays in a routine clinical setting. Preeclamptic women (n = 39) were included shortly after the time of diagnosis. Normotensive control pregnancies were matched by gestational age (n = 76). The KRYPTOR assays performed comparably or superior to Elecsys (sFlt-1/PlGF area under the curve 0.746 versus 0.735; P = .09; for non-obese 0.820 versus 0.805, P = .047). For early-onset preeclampsia, KRYPTOR area under the curve increased to 0.929 with a 100% specificity for preeclampsia at cut-off 85 and an 88.9% sensitivity for preeclampsia at cut-off 33. For women with preeclampsia and preterm delivery or Hemolysis, Elevated Liver enzymes, Low Platelet count (HELLP) syndrome, the KRYPTOR sFlt-1/PlGF ratio was manifold increased (P < .01). The sFlt-1/PlGF ratio proved especially useful in early-onset preeclampsia, preeclampsia with preterm delivery or HELLP, and among non-obese women. Copyright © 2015 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  6. [Preparation of sodium alginate-nanohydroxyapatite composite material for bone repair and its biocompatibility].

    PubMed

    Wang, Yanmei; He, Jiacai; Li, Quanli; Shen, Jijia

    2014-02-01

    To prepare sodium alginate-nanohydroxyapatite composite material and to explore its feasibility as a bone repair material. Sodium alginate-nanohydroxyapatite composite material was prepared using chemical cross-linking and freeze-drying technology. The composite was characterized by X-ray diffraction (XRD) and scanning electron microscope (SEM) and its porosity was measured by liquid displacement method. The fifth passage of bone marrow stromal stem cells (BMSCs) were incubated on the composite material and then growth was observed by inverted microscope and SEM. BMSCs were cultured with liquid extracts of the material, methyl thiazolyl tetrazolium (MTT) assay was used to calculate the relative growth rate (RGR) on 1, 3, 5 d and to evaluate the cytotoxicity. Fresh dog blood was added into the liquid extracts to conduct hemolysis test, the spectrophotometer was used to determine the optical density (OD) and to calculate the hemolysis rate. Sodium alginate-nanohydroxyapatite composite material displayed porosity, the porous pore rate was (88.6 +/- 4.5)%. BMSCs showed full stretching and vigorous growth under inverted microscope and SEM. BMSCs cultured with liquid extracts of the material had good activities. The toxicity of composite material was graded as 1. Hemolysis test results showed that the hemolysis rate of the composite material was 1.28%, thus meeting the requirement of medical biomaterials. The composite material fabricated in this study has high porosity and good biocompatibility.

  7. Intravascular hemolysis induced by phospholipases A2 from the venom of the Eastern coral snake, Micrurus fulvius: Functional profiles of hemolytic and non-hemolytic isoforms.

    PubMed

    Fernández, María Laura; Quartino, Pablo Yunes; Arce-Bejarano, Ruth; Fernández, Julián; Camacho, Luis F; Gutiérrez, José María; Kuemmel, Daniel; Fidelio, Gerardo; Lomonte, Bruno

    2018-04-01

    A unique feature of the venom of Micrurus fulvius (Eastern coral snake) is its ability to induce severe intravascular hemolysis in particular species, such as dogs or mice. This effect was previously shown to be induced by distinct phospholipase A 2 (PLA 2 ) isoforms which cause direct hemolysis in vitro, an uncommon finding for such enzymes. The functional profiles of PLA 2 -17, a direct hemolytic enzyme, and PLA 2 -12, a co-existing venom isoform lacking such effect, were compared. The enzymes differed not only in their ability to cause intravascular hemolysis: PLA 2 -17 additionally displayed lethal, myotoxic, and anticoagulant actions, whereas PLA 2 -12 lacked these effects. PLA 2 -12 was much more active in hydrolyzing a monodisperse synthetic substrate than PLA 2 -17, but the catalytic activity of latter was notably higher on a micellar substrate, or towards pure phospholipid artificial monolayers under controlled lateral pressures. Interestingly, PLA 2 -17 could hydrolyze substrate at a pressure of 20 mN m -1 , in contrast to PLA 2 -12 or the non-toxic pancreatic PLA 2 . This suggests important differences in the monolayer penetrating power, which could be related to differences in toxicity. Comparative examination of primary structures and predicted three-dimensional folding of PLA 2 -12 and PLA 2 -17, revealed that differences concentrate in their N-terminal and central regions, leading to variations of the surface properties at the membrane interacting interface. PLA 2 -17 presents a less basic interfacial surface than PLA 2 -12, but more bulky aromatic residues, which could be associated to its higher membrane-penetrating strength. Altogether, these structural and functional comparative observations suggest that the ability of PLA 2 s to penetrate substrate interfaces could be a major determinant of toxicity, perhaps more important than protein surface charge. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Binary release of ascorbic acid and lecithin from core-shell nanofibers on blood-contacting surface for reducing long-term hemolysis of erythrocyte.

    PubMed

    Shi, Qiang; Fan, Qunfu; Ye, Wei; Hou, Jianwen; Wong, Shing-Chung; Xu, Xiaodong; Yin, Jinghua

    2015-01-01

    There is an urgent need to develop blood-contacting biomaterials with long-term anti-hemolytic capability. To obtain such biomaterials, we coaxially electrospin [ascorbic acid (AA) and lecithin]/poly (ethylene oxide) (PEO) core-shell nanofibers onto the surface of styrene-b-(ethylene-co-butylene)-b-styrene elastomer (SEBS) that has been grafted with poly (ethylene glycol) (PEG) chains. Our strategy is based on that the grafted layers of PEG render the surface hydrophilic to reduce the mechanical injure to red blood cells (RBCs) while the AA and lecithin released from nanofibers on blood-contacting surface can actively interact with RBCs to decrease the oxidative damage to RBCs. We demonstrate that (AA and lecithin)/PEO core-shell structured nanofibers have been fabricated on the PEG grafted surface. The binary release of AA and lecithin in the distilled water is in a controlled manner and lasts for almost 5 days; during RBCs preservation, AA acts as an antioxidant and lecithin as a lipid supplier to the membrane of erythrocytes, resulting in low mechanical fragility and hemolysis of RBCs, as well as high deformability of stored RBCs. Our work thus makes a new approach to fabricate blood-contacting biomaterials with the capability of long-term anti-hemolysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Experimental Assays to Assess the Efficacy of Vinegar and Other Topical First-Aid Approaches on Cubozoan (Alatina alata) Tentacle Firing and Venom Toxicity

    PubMed Central

    Yanagihara, Angel A.; Wilcox, Christie; King, Rebecca; Hurwitz, Kikiana; Castelfranco, Ann M.

    2016-01-01

    Despite the medical urgency presented by cubozoan envenomations, ineffective and contradictory first-aid management recommendations persist. A critical barrier to progress has been the lack of readily available and reproducible envenomation assays that (1) recapitulate live-tentacle stings; (2) allow quantitation and imaging of cnidae discharge; (3) allow primary quantitation of venom toxicity; and (4) employ rigorous controls. We report the implementation of an integrated array of three experimental approaches designed to meet the above-stated criteria. Mechanistically overlapping, yet distinct, the three approaches comprised (1) direct application of test solutions on live tentacles (termed tentacle solution assay, or TSA) with single image- and video-microscopy; (2) spontaneous stinging assay using freshly excised tentacles overlaid on substrate of live human red blood cells suspended in agarose (tentacle blood agarose assays, or TBAA); and (3) a “skin” covered adaptation of TBAA (tentacle skin blood agarose assay, or TSBAA). We report the use and results of these assays to evaluate the efficacy of topical first-aid approaches to inhibit tentacle firing and venom activity. TSA results included the potent stimulation of massive cnidae discharge by alcohols but only moderate induction by urine, freshwater, and “cola” (carbonated soft drink). Although vinegar, the 40-year field standard of first aid for the removal of adherent tentacles, completely inhibited cnidae firing in TSA and TSBAA ex vivo models, the most striking inhibition of both tentacle firing and subsequent venom-induced hemolysis was observed using newly-developed proprietary formulations (Sting No More™) containing copper gluconate, magnesium sulfate, and urea. PMID:26761033

  10. Experimental Assays to Assess the Efficacy of Vinegar and Other Topical First-Aid Approaches on Cubozoan (Alatina alata) Tentacle Firing and Venom Toxicity.

    PubMed

    Yanagihara, Angel A; Wilcox, Christie; King, Rebecca; Hurwitz, Kikiana; Castelfranco, Ann M

    2016-01-11

    Despite the medical urgency presented by cubozoan envenomations, ineffective and contradictory first-aid management recommendations persist. A critical barrier to progress has been the lack of readily available and reproducible envenomation assays that (1) recapitulate live-tentacle stings; (2) allow quantitation and imaging of cnidae discharge; (3) allow primary quantitation of venom toxicity; and (4) employ rigorous controls. We report the implementation of an integrated array of three experimental approaches designed to meet the above-stated criteria. Mechanistically overlapping, yet distinct, the three approaches comprised (1) direct application of test solutions on live tentacles (termed tentacle solution assay, or TSA) with single image- and video-microscopy; (2) spontaneous stinging assay using freshly excised tentacles overlaid on substrate of live human red blood cells suspended in agarose (tentacle blood agarose assays, or TBAA); and (3) a "skin" covered adaptation of TBAA (tentacle skin blood agarose assay, or TSBAA). We report the use and results of these assays to evaluate the efficacy of topical first-aid approaches to inhibit tentacle firing and venom activity. TSA results included the potent stimulation of massive cnidae discharge by alcohols but only moderate induction by urine, freshwater, and "cola" (carbonated soft drink). Although vinegar, the 40-year field standard of first aid for the removal of adherent tentacles, completely inhibited cnidae firing in TSA and TSBAA ex vivo models, the most striking inhibition of both tentacle firing and subsequent venom-induced hemolysis was observed using newly-developed proprietary formulations (Sting No More™) containing copper gluconate, magnesium sulfate, and urea.

  11. Synthesis, characterization and hemolysis studies of Zn(1-x)CaxFe2O4 ferrites synthesized by sol-gel for hyperthermia treatment applications

    NASA Astrophysics Data System (ADS)

    Jasso-Terán, Rosario Argentina; Cortés-Hernández, Dora Alicia; Sánchez-Fuentes, Héctor Javier; Reyes-Rodríguez, Pamela Yajaira; de-León-Prado, Laura Elena; Escobedo-Bocardo, José Concepción; Almanza-Robles, José Manuel

    2017-04-01

    The synthesis of Zn(1-x)CaxFe2O4 nanoparticles, x=0, 0.25, 0.50, 0.75 and 1.0, was performed by sol-gel method followed by a heat treatment at 400 °C for 30 min. These ferrites showed nanometric sizes and nearly superparamagnetic behavior. The Zn0.50Ca0.50Fe2O4 and CaFe2O4 ferrites presented a size within the range of 12-14 nm and appropriate heating ability for hyperthermia applications. Hemolysis testing demonstrated that Zn0.50Ca0.50Fe2O4 ferrite was not cytotoxic when using 10 mg of ferrite/mL of solution. According to the results obtained, Zn0.50Ca0.50Fe2O4 is a potential material for cancer treatment by magnetic hyperthermia therapy.

  12. Life-threatening postpartum hemolysis, elevated liver functions tests, low platelets syndrome versus thrombocytopenic purpura - Therapeutic plasma exchange is the answer.

    PubMed

    Nasa, Prashant; Dua, J M; Kansal, Sudha; Chadha, Geeta; Chawla, Rajesh; Manchanda, Manav

    2011-04-01

    The differential diagnosis of life-threatening microangiopathic disorders in a postpartum female includes severe preeclampsia-eclampsia, hemolysis, elevated liver functions tests, low platelets syndrome and thrombotic thrombocytopenic purpura. There is considerable overlapping in the clinical and laboratory findings between these conditions, and hence an exact diagnosis may not be always possible. However, there is considerable maternal mortality and morbidity associated with these disorders. This case underlines the complexity of pregnancy-related microangiopathies regarding their differential diagnosis, multiple organ dysfunction and role of therapeutic plasma exchange in their management.

  13. Life-threatening postpartum hemolysis, elevated liver functions tests, low platelets syndrome versus thrombocytopenic purpura – Therapeutic plasma exchange is the answer

    PubMed Central

    Nasa, Prashant; Dua, J. M.; Kansal, Sudha; Chadha, Geeta; Chawla, Rajesh; Manchanda, Manav

    2011-01-01

    The differential diagnosis of life-threatening microangiopathic disorders in a postpartum female includes severe preeclampsia–eclampsia, hemolysis, elevated liver functions tests, low platelets syndrome and thrombotic thrombocytopenic purpura. There is considerable overlapping in the clinical and laboratory findings between these conditions, and hence an exact diagnosis may not be always possible. However, there is considerable maternal mortality and morbidity associated with these disorders. This case underlines the complexity of pregnancy-related microangiopathies regarding their differential diagnosis, multiple organ dysfunction and role of therapeutic plasma exchange in their management. PMID:21814380

  14. THE MECHANISM OF THE INHIBITION OF HEMOLYSIS

    PubMed Central

    Ponder, Eric

    1946-01-01

    This paper is concerned with hemolytic systems containing sodium taurocholate, sodium glycocholate, or saponin, and either human red cells or the ghosts (stromata) of human red cells. The lysins are allowed to react with the cells for a short time (1 minute or less), and with the ghosts for a long time (4 hours), and the quantity of lysin remaining in the bulk phase, after the removal of the cells or of the ghosts, is found by (a) colorimetric methods, and (b) methods which measure its hemolytic activity. In the experiments in which the lysins react with the cells for a time so short that none of them is hemolyzed, it is found: (1) that the suspension medium of a cell suspension contains inhibitory substances which render a small amount of the lysin non-lytic, (2) that on the addition of the lysin to the cell suspension, a further and much larger amount of lysin is rendered non-lytic, and (3) that the quantity of chromogenic material in the bulk phase, after the lysin has been in contact with the cells and the latter have been removed, is substantially the same as that initially present. No appreciable quantity of lysin, accordingly, accumulates in increased concentration at the cell surfaces. The results of the colorimetric determinations show that the apparent disappearance of lysin from the bulk phase, once thought to be due to an accumulation of lysin at the cell surfaces, is the result either of an inhibitory process or of a sudden utilization of lysin unrecognized by existing theory. In the experiments in which the lysins react with stromata for 4 hours, it is found: (1) that the suspension medium of a stroma suspension contains inhibitory substances which render some of the lysin non-lytic, (2) that when the lysin reacts with the stromata over a period of time, a much greater quantity of lysin is rendered non-lytic, and (3) that the concentration of chromogenic material in the bulk phase of the lysin-stroma system, after 4 hours of reaction, is substantially

  15. Evaluation of the effect of brominated flame retardants on hemoglobin oxidation and hemolysis in human erythrocytes.

    PubMed

    Jarosiewicz, Monika; Duchnowicz, Piotr; Włuka, Anna; Bukowska, Bożena

    2017-11-01

    Brominated flame retardants (BFRs) are widely used in many everyday products. Numerous studies have shown that BFRs can be released into the environment. Environmental pollution with these compounds raises concerns about their potentially adverse health effects. The aim of this study was to evaluate the effect of tetrabromobisphenol A (TBBPA), tetrabromobisphenol S (TBBPS), 2,4-dibromophenol (2,4-DBP), 2,4,6- tribromophenol (2,4,6-TBP) and pentabromophenol (PBP) on hemolysis induction and hemoglobin oxidation in human erythrocytes. The erythrocytes were incubated with selected BFRs in a wide concentrations ranging from 0.01 to 100 μg/ml for 24 h, 48 h and 72 h. All compounds studied, exhibited hemolytic potential and induced methemoglobin formation. Hemolytic and oxidative potential of BFRs increased along with the increasing concentrations of the compounds studied and elongation of the incubation time. Our study showed that both the number of aromatic rings and the number of bromine atoms in the molecule of the compounds examined influence hemoglobin oxidation and damage to the cellular membrane. Furthermore, we may conclude that 2,4-DBP is potentially most toxic compound because it causes statistically significant changes at the lowest concentration, while the highest toxicity at the highest concentrations was noted for TBBPA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Hemolysis, myopathy, and cardiac disease associated with hereditary phosphofructokinase deficiency in two Whippets

    PubMed Central

    Gerber, Karen; Harvey, John W.; D'Agorne, Sara; Wood, Jonathan; Giger, Urs

    2009-01-01

    Two male castrated Whippet littermates were presented at 1 year of age for pallor, tachycardia, systolic heart murmur, dark yellow to orange feces, intermittent lethargy, pigmenturia, and muscle shivering or cramping after exercise. Persistent macrocytic hypochromic anemia with marked reticulocytosis and metarubricytosis was found when CBC results were compared with reference values for Whippets. Increased serum creatine kinase activity and hyperkalemia also were sometimes present over the 4-year period of evaluation. Progressively increasing serum concentrations of N-terminal prohormone brain natriuretic peptide suggested cardiac disease. Erythrocytes from the whippets were less osmotically fragile but more alkaline fragile than those from control dogs. Erythrocyte phosphofructokinase (PFK) activities and 2,3-diphosphoglycerate concentrations were decreased. Restriction enzyme-based DNA test screening and DNA sequencing revealed the same mutation in the muscle-PFK gene of the Whippets as seen in English Springer Spaniel dogs with PFK deficiency. This is the first report of PFK deficiency in Whippet dogs. In addition to causing hemolysis and exertional myopathy, heart disease may be a prominent clinical component of PFK deficiency in this breed and has not been previously recognized in PFK-deficient English Springer Spaniels. PMID:19228357

  17. Simultaneous determination of hemolysis and hematocrit in extracorporeal circulation by plasma surface reflectance spectroscopy.

    PubMed

    Sakota, Daisuke; Kani, Yuki; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu

    2013-01-01

    To achieve quantitative non-invasive optical diagnosis of blood abnormalities during extracorporeal circulation therapies, plasma surface reflectance spectroscopy was developed by implementing oblique-incidence optical fiber reflectometry on the surface of circulating blood. The reflected light in the wavelength range from 450 to 600 nm changed with respect to the plasma free hemoglobin level and could be used to quantify the free hemoglobin at an accuracy of 5.7 ± 3.5 mg/dL. In contrast, the spectrum did not changed by varying the hematocrit. In the wavelength range from 600 to 800 nm, the obtained spectrum was affected by both the hematocrit change and hemolysis. The linear correlation between the hematocrit value and the spectrum was confirmed at R(2) = 0.99. The feasibility of determining of the hematocrit of arbitrary hemolyzed blood was confirmed. The developed system permits the extraction of the optical characteristics of both plasma and red blood cells without centrifugation. The study establishes non-invasive optical diagnostics capable of analyzing the optical properties of both plasma and red blood cells.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soileau, S.D.

    Chlordecone (CHLO, 1-30 uM) and chlordecone alcohol (CHLO ALC, 1-23 uM) altered the permeability of isolated ovine erythrocytes (OE) as evidenced by a concentration- and time-dependent induction of K/sup +/ efflux and hemolysis. Hemolysis, but no K/sup +/ efflux, was markedly delayed when OE were suspended in isotonic sucrose. Low concentrations of both compounds (1-4 uM) protected OE against hypotonic hemolysis. Neither CHLO (30 uM) nor CHLO ALC (23 uM) induced the release of trapped K/sup +/ from KSCN-loaded, OE-lipid, unilamellar liposomes. CHLO- and CHLO ACL-induced hemolysis and K/sup +/ efflux were dependent upon the pH of the external media.more » CHLO ALC-induced K/sup +/ efflux and hemolysis showed a slight pH dependence, with increased potency of the compound detected over the pH range 8.3-9.4 CHLO ALC-induced protection against hypotonic hemolysis was pH independent. The potency of CHLO in all three assays decreased as the pH was raised from 6.4 to 9.4. (/sup 14/C)-CHLO and (/sup 14/C)-CHLO ALC binding to OE and OE membranes was pH independent. However, the binding of (/sup 14/C)-CHLO to polypropylene and glass was pH dependent. (/sup 14/C)-CHLO binding to polypropylene and glass decreased from pH 6.4 to pH 10.4. The pKa of CHLO was estimated to be 8.9. After the CHLO results were corrected for the fraction of CHLO present in the unionized form, it was estimated the ionized CHLO possessed 1/3 to 1/20 of the activity of the unionized species.« less

  19. Development of binding assays in microfabricated picoliter vials: an assay for biotin.

    PubMed

    Grosvenor, A L; Feltus, A; Conover, R C; Daunert, S; Anderson, K W

    2000-06-01

    A homogeneous binding assay for the detection of biotin in picoliter vials was developed using the photoprotein aequorin as the label. The binding assay was based on the competition of free biotin with biotinylated aequorin (AEQ-biotin) for avidin. A sequential protocol was used, and modification of the assay to reduce the number of steps was examined. Results showed that detection limits on the order of 10(-14) mol of biotin were possible. Reducing the number of steps provided similar detection limits but only if the amount of avidin used was decreased. These binding assays based on picoliter volumes have potential applications in a variety of fields, including microanalysis and single-cell analysis, where the amount of sample is limited. In addition, these assays are suitable for the high-throughput screening of biopharmaceuticals.

  20. Fulminant liver failure resulting from massive hepatic infarction associated with hemolysis, elevated liver enzymes, and low platelets syndrome.

    PubMed

    Yoshihara, Masato; Mayama, Michinori; Ukai, Mayu; Tano, Sho; Kishigami, Yasuyuki; Oguchi, Hidenori

    2016-10-01

    Hepatic infarction is an extremely rare and fatal complication associated with hemolysis, elevated liver enzymes, and low platelets (HELLP) syndrome. It can develop into fulminant liver failure, which increases both maternal and neonatal mortality rates. A 34-year-old woman with no remarkable past medical history developed eclampsia after delivery at 40 weeks of gestation. Imaging indicated massive hepatic infarction and rupture followed by cardiac arrest and fulminant liver failure. Despite liver replacement therapy with plasma exchange and continuous hemodiafiltration, the patient gradually deteriorated with persistent bacterial infection until death at 98 days after delivery. The management of fulminant liver failure complicated with HELLP syndrome should be multidisciplinary. Liver transplantation, the only radical treatment for fulminant liver failure, is worth attempting, if applicable. © 2016 Japan Society of Obstetrics and Gynecology.

  1. ESR study of a biological assay on whole blood: antioxidant efficiency of various vitamins.

    PubMed

    Stocker, Pierre; Lesgards, Jean-François; Vidal, Nicolas; Chalier, Florence; Prost, Michel

    2003-04-07

    This study deals with the activity of various vitamins against the radical-mediated oxidative damage in human whole blood. We have used a biological method that allows both the evaluation of plasma and that of red blood cell resistance against the free radicals induced by 2,2'-azobis (2-amidinopropane) hydrochloride (AAPH). Spin trapping measures using mainly 5-(diethoxyphosphoryl)-5-methyl-1-pyrolline N-oxide nitrone (DEPMPO) were carried out under several conditions to identify the free radicals implicated in this test. Only the oxygenated-centred radical generated from AAPH was found highly reactive to initiate red blood cell lysis. With DEPMPO only alkoxyl radicals were observed and no evidence was found for alkylperoxyl radicals. The antioxidant activity of several lipid- and water-soluble vitamins has been assessed by the biological assay and through two chemical methods. We have noticed high antioxidant activities for tocopherols (in the order delta>gamma>alpha) in the biological test but not through chemical methods. At 1 microM, the delta-tocopherol efficiency in inhibiting radical-induced red blood cell hemolysis was three times as high as the alpha-tocopherol efficiency. For beta-carotene no significant activity even in whole blood was shown. Highly surprising antioxidant activities were observed for acid folic and pyridoxine, compared to ascorbic acid. At 10 microM, the effectiveness of folic acid was almost three times as high as vitamin C. The biological test seems clinically more relevant than most other common assays because it can detect several classes of antioxidants.

  2. Discordant correlation between serological assays observed when measuring heterosubtypic responses against avian influenza H5 and H7 viruses in unexposed individuals.

    PubMed

    Molesti, Eleonora; Ferrara, Francesca; Lapini, Giulia; Montomoli, Emanuele; Temperton, Nigel

    2014-01-01

    The human population is constantly exposed to multiple influenza A subtypes due to zoonotic spillover and rapid viral evolution driven by intrinsic error-prone replication and immunological pressure. In this context, antibody responses directed against the HA protein are of importance since they have been shown to correlate with protective immunity. Serological techniques, detecting these responses, play a critical role for influenza surveillance, vaccine development, and assessment. As the recent human pandemics and avian influenza outbreaks have demonstrated, there is an urgent need to be better prepared to assess the contribution of the antibody response to protection against newly emerged viruses and to evaluate the extent of preexisting heterosubtypic immunity in populations. In this study, 68 serum samples collected from the Italian population between 1992 and 2007 were found to be positive for antibodies against H5N1 as determined by single radial hemolysis (SRH), but most were negative when evaluated using haemagglutination inhibition (HI) and microneutralisation (MN) assays. As a result of these discordant serological findings, the increased sensitivity of lentiviral pseudotypes was exploited in pseudotype-based neutralisation (pp-NT) assays and the results obtained provide further insight into the complex nature of humoral immunity against influenza A viruses.

  3. Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots

    PubMed Central

    2010-01-01

    Background Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. Methods A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Results Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. Conclusions The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration. PMID:20684792

  4. Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots.

    PubMed

    Kuwahata, Melissa; Wijesinghe, Rushika; Ho, Mei-Fong; Pelecanos, Anita; Bobogare, Albino; Landry, Losi; Bugora, Hugo; Vallely, Andrew; McCarthy, James

    2010-08-05

    Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration.

  5. Multiplex tandem mass spectrometry assay for newborn screening of X-linked adrenoleukodystrophy, biotinidase deficiency, and galactosemia with flexibility to assay other enzyme assays and biomarkers.

    PubMed

    Hong, Xinying; Kumar, Arun Babu; Ronald Scott, C; Gelb, Michael H

    2018-03-29

    All States screen for biotinidase deficiency and galactosemia, and X-linked adrenoleukodystrophy (X-ALD) has recently been added to the Recommended Uniform Screening Panel (RUSP).We sought to consolidate these tests by combining them into a single multiplex tandem mass spectrometry assay as well as to improve the current protocol for newborn screening of galactosemia.A 3 mm punch of a dried blood spot (DBS) was extracted with organic solvent for analysis of the C26:0-lysophosphatidylcholine biomarker for X-ALD.An additional punch was used to assay galactose-1-phosphate uridyltransferase (GALT) and biotinidase.All assays were combined for a single injection for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (2.3 min per sample).The GALT LC-MS/MS assay does not give a false positive for galactosemia if glucose-6-phosphate dehydrogenase is deficient.The multiplex assay shows acceptable reproducibility and provides for rapid analysis of X-ALD, biotinidase deficiency, and galactosemia.The throughput and ease of sample preparation are acceptable for newborn screening laboratories.We also show that the LC-MS/MS assay is expandable to include several other diseases including Pompe and Hurler diseases (enzymatic activities and biomarkers).Because of consolidation of assays, less manpower is needed compared to running individual assays on separate platforms.The flexibility of the LC-MS/MS platform allows each newborn screening laboratory to analyze the set of diseases offered in their panel. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Assessment of cytotoxic and genotoxic potential of refinery waste effluent using plant, animal and bacterial systems.

    PubMed

    Gupta, Amit Kumar; Ahmad, Masood

    2012-01-30

    The work described here presents the toxic effect of Mathura refinery wastewater (MRWW) in plant (Allium cepa), bacterial (E. coli K12) and human (blood) system. The samples were collected from adjoining area of Mathura refinery, Dist. Mathura, U.P. (India). Chromosomal aberration test and micronucleus assay in (A. cepa) system, E. coli K12 survival assay as well as hemolysis assay in human blood were employed to assess the toxicity of MRWW. MRWW exposure resulted in the formation of micronuclei and bridges in chromosomes of A. cepa cells. A significant decline occurred in survival of DNA repair defective mutants of E. coli K12 exposed to MRWW. On incubation with MRWW, calf thymus DNA-EtBr fluorescence intensity decreased and percent hemolysis of human blood cells increased. An induction in the MDA levels of MRWW treated A. cepa roots indicated lipid peroxidation also. Collectively, the results demonstrate a significant genotoxic and cytotoxic potential of MRWW. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Posttransfusion survival (24-hour) and hemolysis of previously frozen, deglycerolized RBCs after storage at 4 degrees C for up to 14 days in sodium chloride alone or sodium chloride supplemented with additive solutions.

    PubMed

    Valeri, C R; Pivacek, L E; Cassidy, G P; Ragno, G

    2000-11-01

    Previously frozen human RBCs currently are glycerolized and deglycerolized by the use of open systems that limit storage of the deglycerolized RBCs at 4 degrees C to only 24 hours. Healthy male volunteers who met AABB requirements for blood donors (n = 38) were studied. A volume of 450 mL of blood was collected into CPDA-1. The RBC concentrates were stored at 4 degrees C for 3 to 6 days before being frozen with 40-percent (wt/vol) glycerol and stored at -80 degrees C. The RBCs were deglycerolized, resuspended in 0.9-percent sodium chloride and 0.2-percent glucose (SG) solution or SG solution supplemented with AS-1, AS-3, or AS-5, and stored in the resuspension medium at 4 degrees C for 14 days. The mean +/- SD freeze-thaw-wash process recovery was 90.0 +/- 4.0 percent for all 38 units. The mean 24-hour posttransfusion survival value was 79 percent for deglycerolized RBC stored at 4 degrees C for 7 days in SG alone, SG plus AS-3, or SG plus AS-5. Deglycerolized RBC that were stored at 4 C for 14 days in SG supplemented with AS-1, AS-3, or AS-5 had a mean 24-hour posttransfusion survival of 74 percent. After 7 days of storage of deglycerolized RBCs in SG alone, the mean hemolysis was 3. 7 percent. After 14 days of storage of deglycerolized RBCs in SG supplemented with AS-1, AS-3, or AS-5, the mean hemolysis was 2.5 percent. The levels of hemolysis did not correlate with the 24-hour posttransfusion survival values.

  8. A Teaspoon Pump for Pumping Blood with High Hydraulic Efficiency and Low Hemolysis Potential.

    PubMed

    Dame, Don

    1996-05-01

    Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required. © 1996 International Society for Artificial Organs.

  9. A teaspoon pump for pumping blood with high hydraulic efficiency and low hemolysis potential.

    PubMed

    Dame, D

    1996-06-01

    Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required.

  10. The type II secretion system is essential for erythrocyte lysis and gut colonization by the leech digestive tract symbiont Aeromonas veronii.

    PubMed

    Maltz, Michele; Graf, Joerg

    2011-01-01

    Hemolysin and the type II secretion system (T2SS) have been shown to be important for virulence in many pathogens, but very few studies have shown their importance in beneficial microbes. Here, we investigated the importance of the type II secretion pathway in the beneficial digestive-tract association of Aeromonas veronii and the medicinal leech Hirudo verbana and revealed a critical role for the hemolysis of erythrocytes. A mutant with a miniTn5 insertion in exeM, which is involved in forming the inner membrane platform in the T2SS, was isolated by screening mutants for loss of hemolysis on blood agar plates. A hemolysis assay was used to quantify the mutant's deficiency in lysing sheep erythrocytes and revealed a 99.9% decrease compared to the parent strain. The importance of the T2SS in the colonization of the symbiotic host was assessed. Colonization assays revealed that the T2SS is critical for initial colonization of the leech gut. The defect was tied to the loss of hemolysin production by performing a colonization assay with blood containing lysed erythrocytes. This restored the colonization defect in the mutant. Complementation of the mutant using the promoter region and exeMN revealed that the T2SS is responsible for secreting hemolysin into the extracellular space and that both the T2SS and hemolysin export by the T2SS are critical for initial establishment of A. veronii in the leech gut.

  11. CPTAC Assay Portal: a repository of targeted proteomic assays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whiteaker, Jeffrey R.; Halusa, Goran; Hoofnagle, Andrew N.

    2014-06-27

    To address these issues, the Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as a public repository of well-characterized quantitative, MS-based, targeted proteomic assays. The purpose of the CPTAC Assay Portal is to facilitate widespread adoption of targeted MS assays by disseminating SOPs, reagents, and assay characterization data for highly characterized assays. A primary aim of the NCI-supported portal is to bring together clinicians or biologists and analytical chemists to answer hypothesis-driven questions using targeted, MS-based assays. Assay content is easily accessed through queries and filters, enabling investigatorsmore » to find assays to proteins relevant to their areas of interest. Detailed characterization data are available for each assay, enabling researchers to evaluate assay performance prior to launching the assay in their own laboratory.« less

  12. Lethal effect of a single dose of rasburicase in a preterm newborn infant.

    PubMed

    Zaramella, Patrizia; De Salvia, Alessandra; Zaninotto, Martina; Baraldi, Maura; Capovilla, Giovanni; De Leo, Domenico; Chiandetti, Lino

    2013-01-01

    This case report describes a preterm newborn infant who was treated with a single dose of rasburicase for an increase in uric acid level. He died on the third day as a result of complications of hemolysis, which appeared to be precipitated by rasburicase. The patient's death was preceded by progressive respiratory insufficiency, lactic acidosis, and hyperbilirubinemia, culminating in refractory hypoxia and hypotension. A postmortem assay for glucose-6-phosphate dehydrogenase showed deficiency and the glucose-6-phosphate dehydrogenase Mediterranean genotype.

  13. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-07-01

    Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Evaluating 6 ricin field detection assays.

    PubMed

    Slotved, Hans-Christian; Sparding, Nadja; Tanassi, Julia Tanas; Steenhard, Nina R; Heegaard, Niels H H

    2014-01-01

    This study presents data showing the performance of 6 commercial detection assays against ricin around concentrations specified as detection limits by the producers. A 2-fold dilution series of 20 ng/ml ricin was prepared and used for testing the lateral-flow kits: BADD, Pro Strips™, ENVI, RAID DX, Ricin BioThreat Alert, and IMASS™ device. Three of the 6 tested field assays (IMASS™ device, ENVI assay, and the BioThreat Alert assay) were able to detect ricin, although differences in the measured detection limits compared to the official detection limits and false-negative results were observed. We were not able to get the BADD, Pro Strips™, and RAID assays to function in our laboratory. We conclude that when purchasing a field responder assay, there is large variation in the specificity of the assays, and a number of in-house tests must be performed to ensure functionality.

  15. Electrodeposition of hydroxyapatite coating on Mg-4.0Zn-1.0Ca-0.6Zr alloy and in vitro evaluation of degradation, hemolysis, and cytotoxicity.

    PubMed

    Guan, Ren-Guo; Johnson, Ian; Cui, Tong; Zhao, Tong; Zhao, Zhan-Yong; Li, Xue; Liu, Huinan

    2012-04-01

    A novel biodegradable Mg-4.0Zn-1.0Ca-0.6Zr (wt %) alloy was successfully produced using a series of metallurgical processes; including melting, casting, rolling, and heat treatment. The hardness and ultimate tensile strength of the alloy sheets increased to 71.2HV and 320 MPa after rolling and then aging for 12 h at 175°C. These mechanical properties were sufficient for load-bearing orthopedic implants. A hydroxyapatite (HA) coating was deposited on the Mg-4.0Zn-1.0Ca-0.6Zr (wt %) alloy using a novel coating process combining alkali heat pretreatment, electrodeposition, and alkali heat posttreatment. The microstructure, composition, and phases of the Mg-4.0Zn-1.0Ca-0.6Zr (wt %) alloy and HA coating were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). The degradation, hemolysis, and cytocompatibility of the HA-coated and uncoated Mg-4.0Zn-1.0Ca-0.6Zr (wt %) alloy were studied in vitro. The corrosion potential (E(corr)) of Mg-4.0Zn-1.0Ca-0.6Zr alloy (-1.72 V) was higher than Mg (-1.95 V), Mg-0.6Ca alloy (-1.91 V) and Mg-1.0Ca alloy (-1.97 V), indicating the Mg-Zn-Ca-Zr alloy would be more corrosion resistant. The initial corrosion potential of the HA-coated Mg alloy sample (-1.51 V) was higher than the uncoated sample (-1.72 V). The hemolysis rates of the HA-coated and uncoated Mg-4.0Zn-1.0Ca-0.6Zr (wt %) alloy samples were both <5%, which met the requirements for implant materials. The HA-coated and uncoated Mg-4.0Zn-1.0Ca-0.6Zr (wt %) alloy samples demonstrated the same cytotoxicity score as the negative control. The HA-coated samples showed a slightly greater relative growth rate (RGR%) of fibroblasts than the uncoated samples. Both the HA-coated and uncoated Mg-4.0Zn-1.0Ca-0.6Zr (wt %) alloy provided evidence of acceptable cytocompatibility for medical applications. Copyright © 2012 Wiley Periodicals, Inc.

  16. Comparison between S+L- assay and LacZ marker rescue assay for detecting replication-competent gammaretroviruses.

    PubMed

    Hashimoto-Gotoh, A; Yoshikawa, R; Miyazawa, T

    2015-09-01

    To avoid contamination of adventitious gammaretroviruses in biological products such as vaccines, it is necessary to check the master seed cells for manufacturing. There are several assays to detect infectious gammaretroviruses. Among these, sarcoma-positive, leukemia-negative (S+L-) assay is a classical infectivity assay, which is often recommended in governmental guidelines. The S+L- cells used in S+L- assay generate unique focus upon the infection of replication-competent gammaretroviruses. Although S+L- assay is well recognized for the detection, their applicability is questionable in some cases. On the other hand, LacZ marker rescue (LMR) assay detects infectious gammaretroviruses by transducing LacZ marker gene to the target cells, which shows lacZ-positive foci if the infectious virus is present. In this study, we compared LMR and S+L- assays for detection of a variety of endogenous and exogenous gammaretroviruses. As results, LMR assay could detect all gammaretroviruses examined. On the other hand, S+L- assay using feline S+L- cells, termed QN10S, could not detect porcine endogenous retrovirus (PERV) subgroups A/B. Further, S+L- mink cells could not detect feline leukemia virus subgroups B in addition to PERV-A/B. These data indicate that LMR assay is better suited to detect wider range of gammaretroviruses. Copyright © 2015 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  17. Bacterial phenotype variants in group B streptococcal toxic shock syndrome.

    PubMed

    Sendi, Parham; Johansson, Linda; Dahesh, Samira; Van-Sorge, Nina M; Darenberg, Jessica; Norgren, Mari; Sjölin, Jan; Nizet, Victor; Norrby-Teglund, Anna

    2009-02-01

    We conducted genetic and functional analyses of isolates from a patient with group B streptococcal (GBS) necrotizing fasciitis and toxic shock syndrome. Tissue cultures simultaneously showed colonies with high hemolysis (HH) and low hemolysis (LH). Conversely, the HH and LH variants exhibited low capsule (LC) and high capsule (HC) expression, respectively. Molecular analysis demonstrated that the 2 GBS variants were of the same clonal origin. Genetic analysis found a 3-bp deletion in the covR gene of the HH/LC variant. Functionally, this isolate was associated with an increased growth rate in vitro and with higher interleukin-8 induction. However, in whole blood, opsonophagocytic and intracellular killing assays, the LH/HC phenotype demonstrated higher resistance to host phagocytic killing. In a murine model, LH/HC resulted in higher levels of bacteremia and increased host mortality rate. These findings demonstrate differences in GBS isolates of the same clonal origin but varying phenotypes.

  18. Bacterial Phenotype Variants in Group B Streptococcal Toxic Shock Syndrome1

    PubMed Central

    Johansson, Linda; Dahesh, Samira; Van Sorge, Nina M.; Darenberg, Jessica; Norgren, Mari; Sjölin, Jan; Nizet, Victor; Norrby-Teglund, Anna

    2009-01-01

    We conducted genetic and functional analyses of isolates from a patient with group B streptococcal (GBS) necrotizing fasciitis and toxic shock syndrome. Tissue cultures simultaneously showed colonies with high hemolysis (HH) and low hemolysis (LH). Conversely, the HH and LH variants exhibited low capsule (LC) and high capsule (HC) expression, respectively. Molecular analysis demonstrated that the 2 GBS variants were of the same clonal origin. Genetic analysis found a 3-bp deletion in the covR gene of the HH/LC variant. Functionally, this isolate was associated with an increased growth rate in vitro and with higher interleukin-8 induction. However, in whole blood, opsonophagocytic and intracellular killing assays, the LH/HC phenotype demonstrated higher resistance to host phagocytic killing. In a murine model, LH/HC resulted in higher levels of bacteremia and increased host mortality rate. These findings demonstrate differences in GBS isolates of the same clonal origin but varying phenotypes. PMID:19193266

  19. Evaluation of Presto(plus) assay and LightMix kit Trichomonas vaginalis assay for detection of Trichomonas vaginalis in dry vaginal swabs.

    PubMed

    de Waaij, Dewi J; Ouburg, Sander; Dubbink, Jan Henk; Peters, Remco P H; Morré, Servaas A

    2016-08-01

    This is an evaluation study of the Presto(plus) Assay for T. vaginalis by comparing to the TIB MOLBIOL LightMix Kit Trichomonas vaginalis Assay using 615 dry collected vaginal and rectal swabs. Discordant samples were analyzed by the Qiagen® Microbial DNA qPCR for TV Assay. Both assays showed comparable performances (McNemar p>0.05). Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Molecular modeling on streptolysin-O of multidrug resistant Streptococcus pyogenes and computer aided screening and in vitro assay for novel herbal inhibitors.

    PubMed

    Skariyachan, Sinosh; Narayan, Naik Sowmyalaxmi; Aggimath, Tejaswini S; Nagaraj, Sushmitha; Reddy, Monika S; Narayanappa, Rajeswari

    2014-03-01

    Streptococcus pyogenes is a notorious pathogenic bacterium which causes various human diseases ranging from localized infections to life threatening invasive diseases. Streptolysin-O (SLO), pore-forming thiol-activated cytolysin, is the major virulent factor for streptococcal infections. Present therapies against streptococcal infections are limited as most of the strains have developed multi-drug resistance to present generation of drugs. Hence, there is a need for alternative therapeutic substances. Structure based virtual screening is a novel platform to select lead molecules with better pharmacokinetic properties. The 3D structure of SLO (not available in native form), essential for such studies, was computationally generated and this homology model was used as probable drug target. Based on literature survey, several phytoligands from 25 medicinal plants were selected. Out of these, leads from 11 plants showed better pharmacokinetic properties. The best lead molecules were screened based on computer aided drug likeness and pharmacokinetic predictions. The inhibitory properties of selected herbal leads against SLO were studied by molecular docking. An in vitro assay was further carried out and variations observed were found to be significant (p<0.05). Antibiotic sensitivity testing was also performed with the clinical strain of Streptococcus pyogenes with conventional drugs. The clinical strain showed multi-drug resistance to conventional drugs. Our study revealed that numerous phytoligands have better inhibitory properties towards the toxin. We noticed that incorporation of selected herbal extracts in blood agar medium showed significant reduction in hemolysis (MIC 300μl/plate), indicating inhibition of SLO. Furthermore, the butanol extracts of selected herbal preparation based on computer aided screening showed significant inhibitory properties at 250 mcg/disc concentration. We also noticed that selected herbal formulations have better antimicrobial

  1. Modeling error in experimental assays using the bootstrap principle: Understanding discrepancies between assays using different dispensing technologies

    PubMed Central

    Hanson, Sonya M.; Ekins, Sean; Chodera, John D.

    2015-01-01

    All experimental assay data contains error, but the magnitude, type, and primary origin of this error is often not obvious. Here, we describe a simple set of assay modeling techniques based on the bootstrap principle that allow sources of error and bias to be simulated and propagated into assay results. We demonstrate how deceptively simple operations—such as the creation of a dilution series with a robotic liquid handler—can significantly amplify imprecision and even contribute substantially to bias. To illustrate these techniques, we review an example of how the choice of dispensing technology can impact assay measurements, and show how large contributions to discrepancies between assays can be easily understood and potentially corrected for. These simple modeling techniques—illustrated with an accompanying IPython notebook—can allow modelers to understand the expected error and bias in experimental datasets, and even help experimentalists design assays to more effectively reach accuracy and imprecision goals. PMID:26678597

  2. Cytotoxicity assay automation

    NASA Technical Reports Server (NTRS)

    Levinthal, E. C.; Payne, R. O.

    1971-01-01

    The design and construction of a system to automatically test HLP antigens are described. Major efforts were made to test and evaluate the performance of such a system, and compare its performance with nonautomatic tissue typing techniques. The system is based on the fluorochromatic cytotoxicity assay. Results show the system will work but is subject to malfunctions after a few samplings, and poses problems in showing correctly the necessary readings.

  3. Comparison of the Second-Generation Digene Hybrid Capture Assay with the Branched-DNA Assay for Measurement of Hepatitis B Virus DNA in Serum

    PubMed Central

    Ho, Stephen K. N.; Chan, Tak Mao; Cheng, Ignatius K. P.; Lai, Kar Neng

    1999-01-01

    The optimal hepatitis B virus (HBV) DNA quantitative assay for clinical use remains to be determined. We examined the sensitivity, linearity, and variability of a novel second-generation antibody capture solution hybridization assay, the Digene Hybrid Capture II assay (HCII), and compared it with another widely used solution hybridization assay, the branched-DNA (bDNA) assay (Quantiplex; Chiron Corp.). Our results showed similar and satisfactory assay linearity values, as well as interassay and intra-assay variability values, for both HCII and bDNA assays across different ranges of HBV DNA. Ninety-one percent of 102 serum samples from hepatitis B surface antigen-positive patients showed concordant results with the two assays. The HCII assay was more sensitive than the bDNA assay by 1 dilution, with the lowest reading being 0.9 pg/ml (3.8 pg/ml by bDNA assay). The HBV DNA seropositivity rates for the 102 samples were 58, 67, and 97% by bDNA, HCII, and nested PCR, respectively. While the relationship between results obtained with the bDNA assay and those with the HCII assay was nonlinear, with the bDNA assay yielding values 2.83 ± 0.92-fold higher than those of the HCII assay, especially at high HBV DNA levels, a linear relationship was observed between the two sets of data after logarithmic conversion. The formula for interassay conversion of results was derived as follows: HBV DNA by HCII (picograms per milliliter) = 3.19 × [HBV DNA by bDNA (megaequivalents per milliliter)]0.866. The HCII assay was technically less complex and required a shorter assay time (4 h) than the bDNA assay (24 h). We conclude that the HCII assay compares favorably with the bDNA assay and offers the additional advantages of increased sensitivity and shorter assay time. The increased sensitivity should be particularly useful in monitoring the efficacy of antiviral therapies and detecting the emergence of drug-resistant HBV mutants. PMID:10405385

  4. Comparison of the second-generation digene hybrid capture assay with the branched-DNA assay for measurement of hepatitis B virus DNA in serum.

    PubMed

    Ho, S K; Chan, T M; Cheng, I K; Lai, K N

    1999-08-01

    The optimal hepatitis B virus (HBV) DNA quantitative assay for clinical use remains to be determined. We examined the sensitivity, linearity, and variability of a novel second-generation antibody capture solution hybridization assay, the Digene Hybrid Capture II assay (HCII), and compared it with another widely used solution hybridization assay, the branched-DNA (bDNA) assay (Quantiplex; Chiron Corp.). Our results showed similar and satisfactory assay linearity values, as well as interassay and intra-assay variability values, for both HCII and bDNA assays across different ranges of HBV DNA. Ninety-one percent of 102 serum samples from hepatitis B surface antigen-positive patients showed concordant results with the two assays. The HCII assay was more sensitive than the bDNA assay by 1 dilution, with the lowest reading being 0.9 pg/ml (3.8 pg/ml by bDNA assay). The HBV DNA seropositivity rates for the 102 samples were 58, 67, and 97% by bDNA, HCII, and nested PCR, respectively. While the relationship between results obtained with the bDNA assay and those with the HCII assay was nonlinear, with the bDNA assay yielding values 2.83 +/- 0.92-fold higher than those of the HCII assay, especially at high HBV DNA levels, a linear relationship was observed between the two sets of data after logarithmic conversion. The formula for interassay conversion of results was derived as follows: HBV DNA by HCII (picograms per milliliter) = 3.19 x [HBV DNA by bDNA (megaequivalents per milliliter)](0.866). The HCII assay was technically less complex and required a shorter assay time (4 h) than the bDNA assay (24 h). We conclude that the HCII assay compares favorably with the bDNA assay and offers the additional advantages of increased sensitivity and shorter assay time. The increased sensitivity should be particularly useful in monitoring the efficacy of antiviral therapies and detecting the emergence of drug-resistant HBV mutants.

  5. Case report: massive postpartum transfusion of Jr(a+) red cells in the presence of anti-Jra.

    PubMed

    Yuan, S; Armour, R; Reid, A; Abdel-Rahman, K F; Rumsey, D M; Phillips, M; Nester, T

    2005-01-01

    Jr(a) is a high-prevalence antigen. The rare Jr(a-) individuals can form anti-Jr(a) after exposure to the Jr(a) antigen through transfusion or pregnancy. The clinical significance of anti-Jr(a) is not well established. This study reports a case of a 31-year-old woman with a previously identified anti-Jr(a) who required massive transfusion of RBCs after developing life-threatening postpartum disseminated intravascular coagulopathy. Despite the emergent transfusion of 15 units of Jr(a) untested RBCs, she did not develop laboratory or clinical evidence of acute hemolysis. The patient's anti-Jr(a) had a pretransfusion titer of 4 and a monocyte monolayer assay (MMA) reactivity of 68.5% (reactivity > 5% is considered capable of shortening the survival of incompatible RBCs). The titer increased fourfold to 64 and the MMA reactivity was 72.5% on Day 10 posttransfusion. Review of laboratory data showed evidence of a mild delayed hemolytic transfusion reaction by Day 10 posttransfusion. Despite rare reports of hemolytic transfusion reactions due to anti-Jr(a) in the literature, most cases, including this one, report that this antibody is clinically insignificant or causes only mild delayed hemolysis. Clinicians should be advised to balance the risks of withholding transfusion with the small chance of significant hemolysis after transfusion of Jr(a+) RBCs in the presence of anti-Jr(a).

  6. Enrichment isolation of adipose-derived stem/stromal cells from the liquid portion of liposuction aspirates with the use of an adherent column.

    PubMed

    Doi, Kentaro; Kuno, Shinichiro; Kobayashi, Akira; Hamabuchi, Takahisa; Kato, Harunosuke; Kinoshita, Kahori; Eto, Hitomi; Aoi, Noriyuki; Yoshimura, Kotaro

    2014-03-01

    Adipose-derived stem/progenitor cells (ASCs) are typically obtained from the lipoaspirates; however, a smaller number of ASCs can be isolated without enzymatic digestion from the infranatant liposuction aspirate fluid (LAF). We evaluated the effectiveness of an adherent column, currently used to isolate mesenchymal stromal cells from bone marrow, to isolate LAF cells. We applied peripheral blood (PB), PB mixed with cultured ASCs (PB-ASC), and LAF solution to the column and divided it into two fractions, the adherent (positive) and the non-adherent (negative) fractions. We compared this method with hypotonic hemolysis (lysis) for the red blood cell count, nucleated cells count and cell compositions as well as functional properties of isolated mesenchymal cells. The column effectively removed red blood cells, though the removal efficiency was slightly inferior to hemolysis. After column processing of PB-ASC, 60.5% of ASCs (53.2% by lysis) were selectively collected in the positive fraction, and the negative fraction contained almost no ASCs. After processing of LAF solution, nucleated cell yields were comparable between the column and hemolysis; however, subsequent adherent culture indicated that a higher average ASC yield was obtained from the column-positive samples than from the lysis samples, suggesting that the column method may be superior to hemolysis for obtaining viable ASCs. Mesenchymal differentiation and network formation assays showed no statistical differences in ASC functions between the lysis and column-positive samples. Our results suggest that a column with non-woven rayon and polyethylene fabrics is useful for isolating stromal vascular fraction cells from LAF solutions for clinical applications. Copyright © 2014 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  7. Comparison of the Chiron Quantiplex branched DNA (bDNA) assay and the Abbott Genostics solution hybridization assay for quantification of hepatitis B viral DNA.

    PubMed

    Kapke, G E; Watson, G; Sheffler, S; Hunt, D; Frederick, C

    1997-01-01

    Several assays for quantification of DNA have been developed and are currently used in research and clinical laboratories. However, comparison of assay results has been difficult owing to the use of different standards and units of measurements as well as differences between assays in dynamic range and quantification limits. Although a few studies have compared results generated by different assays, there has been no consensus on conversion factors and thorough analysis has been precluded by small sample size and limited dynamic range studied. In this study, we have compared the Chiron branched DNA (bDNA) and Abbott liquid hybridization assays for quantification of hepatitis B virus (HBV) DNA in clinical specimens and have derived conversion factors to facilitate comparison of assay results. Additivity and variance stabilizing (AVAS) regression, a form of non-linear regression analysis, was performed on assay results for specimens from HBV clinical trials. Our results show that there is a strong linear relationship (R2 = 0.96) between log Chiron and log Abbott assay results. Conversion factors derived from regression analyses were found to be non-constant and ranged from 6-40. Analysis of paired assay results below and above each assay's limit of quantification (LOQ) indicated that a significantly (P < 0.01) larger proportion of observations were below the Abbott assay LOQ but above the Chiron assay LOQ, indicating that the Chiron assay is significantly more sensitive than the Abbott assay. Testing of replicate specimens showed that the Chiron assay consistently yielded lower per cent coefficients of variance (% CVs) than the Abbott assay, indicating that the Chiron assay provides superior precision.

  8. Hemolysis in sickle cell mice causes pulmonary hypertension due to global impairment in nitric oxide bioavailability

    PubMed Central

    Champion, Hunter C.; Campbell-Lee, Sally A.; Bivalacqua, Trinity J.; Manci, Elizabeth A.; Diwan, Bhalchandra A.; Schimel, Daniel M.; Cochard, Audrey E.; Wang, Xunde; Schechter, Alan N.; Noguchi, Constance T.; Gladwin, Mark T.

    2007-01-01

    Pulmonary hypertension is a highly prevalent complication of sickle cell disease and is a strong risk factor for early mortality. However, the pathophysiologic mechanisms leading to pulmonary vasculopathy remain unclear. Transgenic mice provide opportunities for mechanistic studies of vascular pathophysiology in an animal model. By microcardiac catheterization, all mice expressing exclusively human sickle hemoglobin had pulmonary hypertension, profound pulmonary and systemic endothelial dysfunction, and vascular instability characterized by diminished responses to authentic nitric oxide (NO), NO donors, and endothelium-dependent vasodilators and enhanced responses to vasoconstrictors. However, endothelium-independent vasodilation in sickle mice was normal. Mechanisms of vasculopathy in sickle mice involve global dysregulation of the NO axis: impaired constitutive nitric oxide synthase activity (NOS) with loss of endothelial NOS (eNOS) dimerization, increased NO scavenging by plasma hemoglobin and superoxide, increased arginase activity, and depleted intravascular nitrite reserves. Light microscopy and computed tomography revealed no plexogenic arterial remodeling or thrombi/emboli. Transplanting sickle marrow into wild-type mice conferred the same phenotype, and similar pathobiology was observed in a nonsickle mouse model of acute alloimmune hemolysis. Although the time course is shorter than typical pulmonary hypertension in human sickle cell disease, these results demonstrate that hemolytic anemia is sufficient to produce endothelial dysfunction and global dysregulation of NO. PMID:17158223

  9. High-content image analysis (HCIA) assay has the highest correlation with direct counting cell suspension compared to the ATP, WST-8 and Alamar blue assays for measurement of cytotoxicity.

    PubMed

    Tahara, Haruna; Matsuda, Shun; Yamamoto, Yusuke; Yoshizawa, Hiroe; Fujita, Masaharu; Katsuoka, Yasuhiro; Kasahara, Toshihiko

    2017-11-01

    Various cytotoxicity assays measuring indicators such as enzyme activity, dye uptake, or cellular ATP content are often performed using 96-well microplates. However, recent reports show that cytotoxicity assays such as the ATP assay and MTS assay underestimate cytotoxicity when compounds such as anti-cancer drugs or mutagens induce cell hypertrophy whilst increasing intracellular ATP content. Therefore, we attempted to evaluate the reliability of a high-content image analysis (HCIA) assay to count cell number in a 96-well microplate automatically without using a cell-number indicator. We compared cytotoxicity results of 25 compounds obtained from ATP, WST-8, Alamar blue, and HCIA assays with those directly measured using an automatic cell counter, and repeating individual experiments thrice. The number of compounds showing low correlation in cell viability measured using cytotoxicity assays compared to automatic cell counting (r 2 <0.8, at least 2 of 3 experiments) were follows: ATP assay; 7; WST-8 assay, 2; Alamar blue assay, 3; HCIA cytotoxicity assay, 0. Compounds for which correlation was poor in 3 assays, except the HCIA assay, induced an increase in nuclear and cell size. However, correlation between cell viability measured by automatic cell counter and the HCIA assay was strong regardless of nuclear and cell size. Additionally, correlation coefficients between IC 50 values obtained from automatic cell counter and from cytotoxicity assays were as follows: ATP assay, 0.80; WST-8 assay, 0.84; Alamar blue assay, 0.84; and HCIA assay, 0.98. From the above, we showed that the HCIA cytotoxicity assay produces similar data to the automatic cell counter and is highly accurate in measuring cytotoxicity. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Improvement in hemocompatibility of chitosan/soy protein composite membranes by heparinization.

    PubMed

    Wang, Xiaomei; Shi, Na; Chen, Yan; Li, Chen; Du, Xinshen; Jin, Weihua; Chen, Yun; Chang, Peter R

    2012-01-01

    To improve the hemocompatibility of chitosan/soy protein isolate composite membranes by heparinization. Chitosan/soy protein isolate membranes (ChS-n, n=0, 10 and 30, corresponding to the soy protein isolate content in the membranes) and heparinized ChS-n membranes (HChS-n) were prepared by blending in dilute HAc/NaAc solution. The hemocompatibility of ChS-n and HChS-n membranes were comparatively evaluated by measuring surface heparin density, blood platelet adhesion, plasma recalcification time (PRT), thrombus formation and hemolysis assay. The surface heparin density analysis showed that heparinized chitosan/SPI soy protein isolate membranes have been successfully prepared by blending. The density of heparin on the surface of HChS-n membranes was in the range of 0.67-1.29 μg/cm2. The results of platelet adhesion measurement showed that the platelet adhesion numbers of HChS-n membranes were lower than those of the corresponding ChS-n membranes. The PRT of the HChS-0, HChS-10 and HChS-30 membranes were around 292, 306 and 295 s, respectively, which were longer than the corresponding ChS-0 (152 s), ChS-10 (204 s) and ChS-30 (273 s) membranes. The hemolysis rate of HChS-n membranes was lower than 1%. The hemocompatibility of ChS membranes could be improved by blending with heparin. Compared with ChS membranes, HChS membranes showed lower platelet adhesion, longer PRT, higher BCI, significant thromboresistivity and a lower hemolysis rate due to the heparinization. This widens the application of chitosan and soy protein-based biomaterials that may come in contact with blood.

  11. Study of Glucose-6-Phosphate Dehydrogenase Deficiency: 5 Years Retrospective Egyptian Study.

    PubMed

    Hagag, Adel A; Badraia, Ibrahim M; Elfarargy, Mohamed S; Abd Elmageed, Mohamed M; Abo-Ali, Ehab A

    2018-02-13

    patients; 2.8%), hepatitis A (18 patients; 1.8%) and urinary tract infection (12 patients; 1.2%). Drugs were the least common cause of hemolysis (42 patients; 4.2%) including diclofenac sodium (24 patients; 2.4%), ibuprofen (8 patients; 0.8%), acetylsalicylic acid (4 patients; 0.4%), co-trimoxazole (4 patients; 0.4%) and nitrofurantion (2 patients; 0.2%). There was normocytic normochromic anemia with reticulocytosis and Heinz bodies in pre-transfusion complete blood picture in all studied cases. G6PD assay show marked decrease in enzyme level at time of presentation in all cases with the commonest G6PD enzyme level of 3-4 U/gm Hb (592 patients; 59.2%). G6PD deficiency anemia presented mainly with pallor, dark red urine and jaundice after exposure to certain diets, drugs and diseases and therefore patients with G6PD deficiency should avoid exposure to these precipitating factors of hemolysis. We can also recommend large neonatal screening programs to detect cases of G6PD deficiency before the occurrence of acute hemolysis and molecular studies to detect G6PD enzyme variant in Egypt. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Serum biotin in Japanese children: Enzyme-linked immunosorbent assay measurement.

    PubMed

    Wakabayashi, Kenji; Kodama, Hiroko; Ogawa, Eishin; Sato, Yasuhiro; Motoyama, Kahoko; Suzuki, Mitsuyoshi

    2016-09-01

    Biotin deficiency has been reported in Japanese infants fed special formulas for medical reasons, including those with milk allergy and congenital metabolic diseases, because these formulas contain little biotin. Serum biotin measurement is useful for diagnosing biotin deficiency. We applied a simple and rapid method to analyze serum biotin, and established normal ranges for children and adults. Serum biotin in 188 healthy Japanese children aged 0-4 years and in 25 healthy adults was analyzed using a Biotin ELISA Kit (immundiagnostik). The effects of various conditions on the measurement of serum biotin were also examined. Median biotin in children aged 0-4 years was 10.4 ng/dL (IQR, 7.9-13.4 ng/dL), and that in adults was 12.9 ng/dL (IQR, 10.8-15.8 ng/dL). Normal range was 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults (calculated using two-sided 95%CI). Measurements obtained with this method were not affected by frozen storage, freeze-thaw, or hemolysis, indicating that serum biotin can be analyzed accurately under these conditions, with a possible application to plasma samples. Serum biotin was significantly lower in children than in adults, with the normal range being 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults. This simple and accurate enzyme-linked immunosorbent assay method is useful for diagnosing biotin deficiency. © 2016 The Authors. Pediatrics International published by John Wiley & Sons Australia, Ltd on behalf of Japan Pediatric Society.

  13. Hemolytic activity in Flavobacterium psychrophilum is a contact-dependent, two-step mechanism and differently expressed in smooth and rough phenotypes.

    PubMed

    Högfors-Rönnholm, Eva; Wiklund, Tom

    2010-12-01

    The hemolytic activity of cells of smooth and rough phenotypic variants of the Gram-negative fish pathogen Flavobacterium psychrophilum was investigated in two different assays, a microplate and an agarose hemolysis assay, using rainbow trout erythrocytes. The smooth cells showed a high and the rough cells a negligible, concentration dependent, hemolytic activity in the microplate assay. Both smooth and rough cells showed a rather weak hemolytic activity, with two distinct hemolytic patterns, in the agarose assay. The hemolytic activity of the cells was not regulated by iron availability and cell-free extracellular products did not show any hemolytic activity. The smooth cells, in contrast to the rough cells, showed a high ability to agglutinate erythrocytes and both hemagglutination and hemolytic activity was impaired by treatment of the cells with sialic acid. The hemolytic activity was furthermore reduced after proteolytic and heat treatment of the cells. The results from the present study suggest that the hemolytic activity in F. psychrophilum is highly expressed in the smooth phenotype, and that it is a contact-dependent and two-step mechanism that is initiated by the binding of the bacterial cells to the erythrocytes through sialic acid-binding lectins and then executed by thermolabile proteinaceous hemolysins. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Proton-sensing transistor systems for detecting ion leakage from plasma membranes under chemical stimuli.

    PubMed

    Imaizumi, Yuki; Goda, Tatsuro; Schaffhauser, Daniel F; Okada, Jun-Ichi; Matsumoto, Akira; Miyahara, Yuji

    2017-03-01

    The membrane integrity of live cells is routinely evaluated for cytotoxicity induced by chemical or physical stimuli. Recent progress in bioengineering means that high-quality toxicity validation is required. Here, we report a pH-sensitive transistor system developed for the continuous monitoring of ion leakage from cell membranes upon challenge by toxic compounds. Temporal changes in pH were generated with high reproducibility via periodic flushing of HepG2 cells on a gate insulator of a proton-sensitive field-effect transistor with isotonic buffer solutions with/without NH 4 Cl. The pH transients at the point of NH 4 Cl addition/withdrawal originated from the free permeation of NH 3 across the semi-permeable plasma membranes, and the proton sponge effect produced by the ammonia equilibrium. Irreversible attenuation of the pH transient was observed when the cells were subjected to a membrane-toxic reagent. Experiments and simulations proved that the decrease in the pH transient was proportional to the area of the ion-permeable pores on the damaged plasma membranes. The pH signal was correlated with the degree of hemolysis produced by the model reagents. The pH assay was sensitive to the formation of molecularly sized pores that were otherwise not measurable via detection of the leakage of hemoglobin, because the hydrodynamic radius of hemoglobin was greater than 3.1nm in the hemolysis assay. The pH transient was not disturbed by inherent ion-transporter activity. The ISFET assay was applied to a wide variety of cell types. The system presented here is fast, sensitive, practical and scalable, and will be useful for validating cytotoxins and nanomaterials. The plasma membrane toxicity and hemolysis are widely and routinely evaluated in biomaterials science and biomedical engineering. Despite the recent development of a variety of methods/materials for efficient gene/drug delivery systems to the cytosol, the methodologies for safety validation remain unchanged in

  15. Integrated bioassays in microfluidic devices: botulinum toxin assays.

    PubMed

    Mangru, Shakuntala; Bentz, Bryan L; Davis, Timothy J; Desai, Nitin; Stabile, Paul J; Schmidt, James J; Millard, Charles B; Bavari, Sina; Kodukula, Krishna

    2005-12-01

    A microfluidic assay was developed for screening botulinum neurotoxin serotype A (BoNT-A) by using a fluorescent resonance energy transfer (FRET) assay. Molded silicone microdevices with integral valves, pumps, and reagent reservoirs were designed and fabricated. Electrical and pneumatic control hardware were constructed, and software was written to automate the assay protocol and data acquisition. Detection was accomplished by fluorescence microscopy. The system was validated with a peptide inhibitor, running 2 parallel assays, as a feasibility demonstration. The small footprint of each bioreactor cell (0.5 cm2) and scalable fluidic architecture enabled many parallel assays on a single chip. The chip is programmable to run a dilution series in each lane, generating concentration-response data for multiple inhibitors. The assay results showed good agreement with the corresponding experiments done at a macroscale level. Although the system has been developed for BoNT-A screening, a wide variety of assays can be performed on the microfluidic chip with little or no modification.

  16. A novel bicomponent hemolysin from Bacillus cereus.

    PubMed Central

    Beecher, D J; MacMillan, J D

    1990-01-01

    A procedure combining isoelectric focusing (Sephadex IEF) and fast protein liquid chromatography (Superose 12; Mono-Q) removed hemolytic activity (presumably a contaminant) from partially purified preparations of the multicomponent diarrheal enterotoxin produced by Bacillus cereus. However, when the separated fractions were recombined, hemolytic activity was restored, suggesting that hemolysis is a property of the enterotoxin components. Combined fractions exhibited a unique ring pattern in gel diffusion assays in blood agar. During diffusion of the hemolysin from an agar well, the erythrocytes closest to the well were not lysed initially. After diffusion, hemolysis was observed as a sharp ring beginning several millimeters away from the edge of the well. With time the cells closer to the well were also lysed. This novel hemolysin consists of a protein (component B) which binds to or alters cells, allowing subsequent lysis by a second protein (component L). Sodium dodecyl sulfate-polyacrylamide gel electrophoresis, isoelectric focusing, and Western blot analysis showed that hemolysin BL has properties similar to those described previously for the enterotoxin and that both components are distinct from cereolysin and cereolysin AB. Images PMID:2114359

  17. Assaying Cellular Viability Using the Neutral Red Uptake Assay.

    PubMed

    Ates, Gamze; Vanhaecke, Tamara; Rogiers, Vera; Rodrigues, Robim M

    2017-01-01

    The neutral red uptake assay is a cell viability assay that allows in vitro quantification of xenobiotic-induced cytotoxicity. The assay relies on the ability of living cells to incorporate and bind neutral red, a weak cationic dye, in lysosomes. As such, cytotoxicity is expressed as a concentration-dependent reduction of the uptake of neutral red after exposure to the xenobiotic under investigation. The neutral red uptake assay is mainly used for hazard assessment in in vitro toxicology applications. This method has also been introduced in regulatory recommendations as part of 3T3-NRU-phototoxicity-assay, which was regulatory accepted in all EU member states in 2000 and in the OECD member states in 2004 as a test guideline (TG 432). The present protocol describes the neutral red uptake assay using the human hepatoma cell line HepG2, which is often employed as an alternative in vitro model for human hepatocytes. As an example, the cytotoxicity of acetaminophen and acetyl salicylic acid is assessed.

  18. A multiwell format assay for heparanase.

    PubMed

    Behzad, Farhad; Brenchley, Paul E C

    2003-09-15

    This assay employs a biotinylated heparan sulfate glycosaminoglycan (HSGAG) substrate that is covalently linked to the surface of 96-well immunoassay plates. The ratio of biotin:HSGAG and the coating concentration of substrate bound to the wells have been optimized and allow removal of biotin HSGAG within 60 min of incubation at 37 degrees C in assay buffer with a standard dilution of bacterial heparitinase or platelet heparanase. Loss of biotin signal from the well surface is detected on incubation with peroxidase-streptavidin followed by color development using 3,3',5,5'-tetramethylbenzidine as the peroxidase substrate. The new assay allows specific detection of heparanase activity in multiple samples in a total time of 3 h including a 1-h substrate digestion step and is a significant improvement with regard to sensitivity, specificity, and ease of handling of multiple samples compared to other described assays. Heparanase specifically degrades the biotinylated HSGAG substrate, when used with an optimized assay buffer. A range of enzymes including collagenase, trypsin, plasmin, pepsin, chondroitinases, hyaluronidase, and neuraminidase show no effect on the substrate under optimized assay conditions. The covalent linkage of the substrate to the well prevents leaching of substrate and allows preparation and long-term storage of substrate-coated plates. The assay can be used to detect heparanase levels in clinical samples and cell culture supernatants and is ideal as a screening method for antagonists of enzyme activity.

  19. Comparison of bioluminescent kinase assays using substrate depletion and product formation.

    PubMed

    Tanega, Cordelle; Shen, Min; Mott, Bryan T; Thomas, Craig J; MacArthur, Ryan; Inglese, James; Auld, Douglas S

    2009-12-01

    Assays for ATPases have been enabled for high-throughput screening (HTS) by employing firefly luciferase to detect the remaining ATP in the assay. However, for any enzyme assay, measurement of product formation is a more sensitive assay design. Recently, technologies that allow detection of the ADP product from ATPase reactions have been described using fluorescent methods of detection. We describe here the characterization of a bioluminescent assay that employs firefly luciferase in a coupled-enzyme assay format to enable detection of ADP levels from ATPase assays (ADP-Glo, Promega Corp.). We determined the performance of the ADP-Glo assay in 1,536-well microtiter plates using the protein kinase Clk4 and a 1,352 member kinase focused combinatorial library. The ADP-Glo assay was compared to the Clk4 assay performed using a bioluminescence ATP-depletion format (Kinase-Glo, Promega Corp). We performed this analysis using quantitative HTS (qHTS) where we determined potency values for all library members and identified approximately 300 compounds with potencies ranging from as low as 50 nM to >10 microM, yielding a robust dataset for the comparison. Both assay formats showed high performance (Z'-factors approximately 0.9) and showed a similar potency distribution for the actives. We conclude that the bioluminescence ADP detection assay system is a viable generic alternative to the widely used ATP-depletion assay for ATPases and discuss the advantages and disadvantages of both approaches.

  20. Concurrent measurement of cellular turbidity and hemoglobin to evaluate the antioxidant activity of plants.

    PubMed

    Bellik, Yuva; Iguer-Ouada, Mokrane

    2016-01-01

    In past decades, a multitude of analytical methods for measuring antioxidant activity of plant extracts has been developed. However, when using methods to determine hemoglobin released from human erythrocytes treated with ginger extracts, we found hemoglobin concentrations were significantly higher than in untreated control samples. This suggests in the presence of antioxidants that measuring hemoglobin alone is not sufficient to determine hemolysis. We show concurrent measurement of erythrocyte concentration and hemoglobin is essential in such assays, and describe a new protocol based on simultaneous measurement of cellular turbidity and hemoglobin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Digital Assays Part II: Digital Protein and Cell Assays.

    PubMed

    Basu, Amar S

    2017-08-01

    A digital assay is one in which the sample is partitioned into many containers such that each partition contains a discrete number of biological entities (0, 1, 2, 3, . . .). A powerful technique in the biologist's toolkit, digital assays bring a new level of precision in quantifying nucleic acids, measuring proteins and their enzymatic activity, and probing single-cell genotype and phenotype. Where part I of this review focused on the fundamentals of partitioning and digital PCR, part II turns its attention to digital protein and cell assays. Digital enzyme assays measure the kinetics of single proteins with enzymatic activity. Digital enzyme-linked immunoassays (ELISAs) quantify antigenic proteins with 2 to 3 log lower detection limit than conventional ELISA, making them well suited for low-abundance biomarkers. Digital cell assays probe single-cell genotype and phenotype, including gene expression, intracellular and surface proteins, metabolic activity, cytotoxicity, and transcriptomes (scRNA-seq). These methods exploit partitioning to 1) isolate single cells or proteins, 2) detect their activity via enzymatic amplification, and 3) tag them individually by coencapsulating them with molecular barcodes. When scaled, digital assays reveal stochastic differences between proteins or cells within a population, a key to understanding biological heterogeneity. This review is intended to give a broad perspective to scientists interested in adopting digital assays into their workflows.

  2. Unsaturated fatty acids show clear elicitation responses in a modified local lymph node assay with an elicitation phase, and test positive in the direct peptide reactivity assay.

    PubMed

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Miyazaki, Hiroshi; Itagaki, Hiroshi

    2015-12-01

    The Organisation for Economic Co-operation and Development (OECD) Test Guidelines (TG) adopted the murine local lymph node assay (LLNA) and guinea pig maximization test (GPMT) as stand-alone skin sensitization test methods. However, unsaturated carbon-carbon double-bond and/or lipid acids afforded false-positive results more frequently in the LLNA compared to those in the GPMT and/or in human subjects. In the current study, oleic, linoleic, linolenic, undecylenic, fumaric, maleic, and succinic acid and squalene were tested in a modified LLNA with an elicitation phase (LLNA:DAE), and in a direct peptide reactivity assay (DPRA) to evaluate their skin-sensitizing potential. Oleic, linoleic, linolenic, undecylenic and maleic acid were positive in the LLNA:DAE, of which three, linoleic, linolenic, and maleic acid were positive in the DPRA. Furthermore, the results of the cross-sensitizing tests using four LLNA:DAE-positive chemicals were negative, indicating a chemical-specific elicitation response. In a previous report, the estimated concentration needed to produce a stimulation index of 3 (EC3) of linolenic acid, squalene, and maleic acid in the LLNA was < 10%. Therefore, these chemicals were classified as moderate skin sensitizers in the LLNA. However, the skin-sensitizing potential of all LLNA:DAE-positive chemicals was estimated as weak. These results suggested that oleic, linoleic, linolenic, undecylenic, and maleic acid had skin-sensitizing potential, and that the LLNA overestimated the skin-sensitizing potential compared to that estimated by the LLNA:DAE.

  3. Comparison of the Abbott Architect i2000 assay, the Roche Modular Analytics E170 assay, and an immunoradiometric assay for serum hepatitis B virus markers.

    PubMed

    Kim, Hyunjung; Oh, Eun-Jee; Kang, Mi-Sook; Kim, Sung Hoon; Park, Yeon-Joon

    2007-01-01

    Serum hepatitis B virus (HBV) markers are the most important data for epidemiological screening and clinical diagnosis of HBV infection, especially in endemic areas. We compared the results of the Roche Modular Analytics E170 assay, the Abbott Architect i2000 assay, and an immunoradiometric assay (IRMA) for HBV surface antigen (HBsAg), anti-HBV surface antigen (anti-HBs), HBV e antigen (HBeAg), and anti-HBV e antigen (anti-HBe). A number of serum samples (264, 263, 224, and 202 for HBsAg, anti-HBs, HBeAg, and anti-HBe, respectively) were studied. For samples giving discrepant results for HBeAg between methods, real-time PCR assays were performed. The concordance rates among the three methods were high for HBsAg (100%) and HBeAg (94.6), but low for anti-HBs (91.6%) and anti-HBe (82.2%). For anti-HBs, which could be measured quantitatively by the Modular E170 and Architect i2000 procedures, discrepant results were observed at low levels of anti-HBs. For anti-HBe, the positive rate was highest with Modular E170 (60.9%) followed by the IRMA kit (54.1%) and Architect i2000 (51.0%). This study shows substantial differences between the assay results by the three methods, which should be taken into account in determinations of serum HBV markers.

  4. Small molecule antagonists of the urokinase (uPA): urokinase receptor (uPAR) interaction with high reported potencies show only weak effects in cell-based competition assays employing the native uPAR ligand.

    PubMed

    De Souza, Melissa; Matthews, Hayden; Lee, Jodi A; Ranson, Marie; Kelso, Michael J

    2011-04-15

    Binding of the urokinase-type plasminogen activator (uPA) to its cell-surface-bound receptor uPAR and upregulation of the plasminogen activation system (PAS) correlates with increased metastasis and poor prognosis in several tumour types. Disruptors of the uPA:uPAR interaction represent promising anti-tumour/metastasis agents and several approaches have been explored for this purpose, including the use of small molecule antagonists. Two highly potent non-peptidic antagonists 1 and 2 (IC(50)1=0.8 nM, IC(50)2=33 nM) from the patent literature were reportedly identified using competition assays employing radiolabelled uPAR-binding uPA fragments and appeared as useful pharmacological tools for studying the PAS. Before proceeding to such studies, confirmation was sought that 1 and 2 retained their potencies in physiologically relevant cell-based competition assays employing uPAR's native binding partner high molecular weight uPA (HMW-uPA). This study describes a new solution phase synthesis of 1, a mixed solid/solution phase synthesis of 2 and reports the activities of 1 and 2 in semi-quantitative competition flow cytometry assays and quantitative cell-based uPA activity assays that employed HMW-uPA as the competing ligand. The flow cytometry experiments revealed that high concentrations of 2 (10-100 μM) are required to compete with HMW-uPA for uPAR binding and that 1 shows no antagonist effects at 100 μM. The cell-based enzyme activity assays similarly revealed that 1 and 2 are poor inhibitors of cell surface-bound HMW-uPA activity (IC(50) >100 μM for 1 and 2). The report highlights the dangers of identifying false-positive lead uPAR antagonists from competition assays employing labelled competing ligands other than the native HMW-uPA. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Amphiphilic Y Shaped Miktoarm Star Copolymer for Anti-Cancer Hydrophobic and Hydrophilic Drugs Co-Delivery: Synthesis, Characterization, In Vitro and In Vivo Biocompatibility Study.

    PubMed

    Aghajanzadeh, Mozhgan; Zamani, Mostafa; Rashidzadeh, Hamid; Rostamizadeh, Kobra; Sharafi, Ali; Danafar, Hossein

    2018-06-16

    In this project, a core-shell Polymersome based on miktoarm star-copolymer: methoxy Poly Ethylene Glycol-Lysine-(Poly Caprolactone) 2 (PEG-Lys-PCL 2 ) was synthesized by a new method as controlled targeted drug delivery systems for co-delivery of the chemotherapeutic methotrexate (MTX) and curcumin (CUR). Some properties of these nano carriers (NCs) such as surface morphology, structure, surface charge, stability and biocompatibility were evaluated by Proton nuclear magnetic resonance ( 1 HNMR), dynamic scanning colorimetry (DSC), Fourier-transform infrared spectroscopy (FT-IR), Dynamic light scattering (DLS), atomic force microscopy (AFM), Critical aggregation concentration (CAC), hemolysis test, MTT assay and lethal dose 50 (LD50). The AFM results showed the uniform spherical morphology of NCs have with average size about ∼60 nm. The drug loading of NCs was about 14.13% and 10.93% for CUR and MTX, respectively. The NCs revealed pH-sensitivity in drug release. Release of drugs from miktoarm-based NCs in neutral pH were lower than in acidic medium, because of faster degradation of Polymersome in acidic environment. MTT assay results showed that the drug-loaded NCs didn't show significant toxicity due to which cell viability maintain over 82% at 300 μg/mL concentration. Also, synthesized miktoarm showed hemolysis lower than 3%. This result was repeat in LD50 and all mice which treat with 5000mg/Kg were still alive after 24 hours. These result confirmed safety of miktoarm star copolymer. Eventually, goal of this study is the application of water-soluble star copolymers miktoarm with pH dependent release properties for design a new drug delivery carrier and using CUR for enhancing anti-cancer properties of MTX. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  6. Total phenolic, total flavonoid content, and antioxidant capacity of the leaves of Meyna spinosa Roxb., an Indian medicinal plant.

    PubMed

    Sen, Saikat; De, Biplab; Devanna, N; Chakraborty, Raja

    2013-03-01

    The objective of the present study was to determine the total phenolic and total flavonoid contents, and to evaluate the antioxidant potential of different leaf extracts of Meyna spinosa Roxb. ex Link, a traditional medicinal plant of India. Free radical scavenging and antioxidant potential of the methanol, ethyl acetate, and petroleum ether extracts of Meyna spinosa leaves were investigated using several in vitro and ex vivo assays, including the 2, 2-diphenyl-picrylhydrazyl radical scavenging, superoxide anion scavenging, hydroxyl radical scavenging, nitric oxide radical scavenging, hydrogen peroxide scavenging activity, metal chelating assay, and reducing power ability method. Total antioxidant activity of the extracts was estimated by the ferric thiocyanate method. Inhibition assay of lipid peroxidation and oxidative hemolysis were also performed to confirm the protective effect of the extracts. Total phenolic and total flavonoid contents of the extracts were estimated using standard chemical assay procedures. Methanol extracts showed the highest polyphenolic content and possessed the better antioxidant activity than the other two extracts. Total phenolic and total flavonoid contents in the methanol extract were (90.08 ± 0.44) mg gallic acid equivalents/g and (58.50 ± 0.09) mg quercetin equivalents/g, respectively. The IC50 of the methanol extract in the DPPH(·), superoxide anion, hydroxyl radical, nitric oxide radical, hydrogen peroxide scavenging activity and metal chelating assays were (16.4 ± 0.41), (35.9 ± 0.19), (24.1 ± 0.33), (23.7 ± 0.09), (126.8 ± 2.92), and (117.2 ± 1.01) μg·mL(-1), respectively. The methanol extract showed potent reducing power ability, total antioxidant activity, and significantly inhibit lipid peroxidation and oxidative hemolysis which was similar to that of standards. The results indicated a direct correlation between the antioxidant activity and the polyphenolic content of the extracts, which may the foremost

  7. A microtitre plate assay for measuring glycosidase activity.

    PubMed

    Ball, Andrea L; Chambers, Kirsty A; Hewinson, Meera; Navaratnarajah, Sambavi; Samrin, Lamia; Thomas, Nesta; Tyler, Abigail E H; Wall, Amanda J; Lloyd, Matthew D

    2008-02-01

    Glycosidases perform a wide range of functions in physiology and pathology, and are potential targets for the treatment of diseases such as influenza, cancer, AIDS and diabetes. This paper reports a convenient discontinuous colourimetric assay for the measurement of glycosidase activity. The assay utilises 4-nitrophenyl- substrates and quantities of product are determined by measuring absorbance at 405 nm. This assay is performed in a 96 well microtitre plate and has been used to characterise the properties of seven different glycosidases from bacteria, yeast and higher eukaryotes and their kinetic parameters determined. Assays in the presence of known inhibitors showed that inhibition modes can be determined, and IC(50) and K(i) values calculated. This assay appears to be of widely applicable and of general utility for the measurement of glycosidase activity and the evaluation of inhibitors.

  8. Hemolysis in runners as evidenced by low serum haptoglobin: Implications for preflight monitoring of astronauts

    NASA Technical Reports Server (NTRS)

    Owens, Joyce; Spitler, Diane L.; Frey, Mary Anne Bassett

    1987-01-01

    Hematological parameters and serum haptoglobin were examined in 21 male employees of the Kennedy Space Center who were at 3 levels of physical activity: 7 subjects regularly ran more than 40 km (25 miles) per week (Group I); 7 ran 13 to 24 km (8 to 15 miles) per week (II), and 7 were sedentary (III). Blood was drawn on a different day of the week for five weeks. Differences between day of the week, visit number, and activity level were examined. No differences were observed for day of week or visit number; thus mean values for each variable were calculated for each subject. Variables did not differ among groups. However, trends with level of training were observed in some critical variables. Hemoglobin (Hb) and hematocrit (Hct) conformed to a staircase effect with Group I (14.5 gm/dl and 41.3 percent) lower than Group III (15.1 gm/dl and 42.9 percent). Reticulocyte count was higher and haptoglobin levels lower in Group I (1.35% and 75.7 gm/dl) than Group III (.99 percent and 132.9 gm/dl), with haptoglobin for the high mileage Group I in the clinically abnormal range. Since haptoglobin binds free Hb following RBC destruction, these results suggest that intravascular hemolysis occurs in trained male runners. These results may have special meaning for astronauts training before long-duration spaceflights, since the further reduction in red blood cells which is reported to occur during spaceflight could become detrimental to their health and performance.

  9. Validation of an LDH Assay for Assessing Nanoparticle Toxicity

    PubMed Central

    Han, Xianglu; Gelein, Robert; Corson, Nancy; Wade-Mercer, Pamela; Jiang, Jingkun; Biswas, Pratim; Finkelstein, Jacob N.; Elder, Alison; Oberdörster, Günter

    2014-01-01

    Studies showed that certain cytotoxicity assays were not suitable for assessing nanoparticle (NP) toxicity. We evaluated a lactate dehydrogenase (LDH) assay for assessing copper (Cu-40, 40 nm), silver (Ag-35, 35 nm; Ag-40, 40 nm), and titanium dioxide (TiO2-25, 25 nm) NPs by examining their potential to inactivate LDH and interference with β-nicotinamide adenine dinucleotide (NADH), a substrate for the assay. We also performed a dissolution assay for some of the NPs. We found that the copper NPs, because of their high dissolution rate, could interfere with the LDH assay by inactivating LDH. Ag-35 could also inactivate LDH probably because of the carbon matrix used to cage the particles during synthesis. TiO2-25 NPs were found to adsorb LDH molecules. In conclusion, NP interference with the LDH assay depends on the type of NPs and the suitability of the assay for assessing NP toxicity should be examined case by case. PMID:21722700

  10. Retinal detachment in hemolysis, elevated liver enzymes, and low platelet count (HELLP) syndrome: Color vision abnormality as the first and predominant manifestation.

    PubMed

    Morisawa, Hiroyuki; Makino, Shinji; Takahashi, Hironori; Sorita, Mari; Matsubara, Shigeki

    2015-11-01

    Serous retinal detachment is sometimes caused by hypertensive disorders in pregnancy and its associated conditions, in which the predominant eye symptoms are blurred vision, distorted vision, and reduced visual acuity. To our best knowledge, this is the first report of a puerperal woman with hemolysis, elevated liver enzymes, and low platelet count (HELLP) syndrome in whom color vision abnormality was the first and predominant manifestation of serous retinal detachment. At 32 weeks of gestation, the 34-year-old Japanese woman underwent cesarean section due to HELLP syndrome. She complained of color vision abnormality on day 1 post-partum and ophthalmological examination revealed serous retinal detachment of both eyes. The visual acuity was preserved. With supportive therapy, her color vision abnormality gradually ameliorated and retinal detachment completely resolved on day 34 post-partum without any sequelae. Obstetricians should be aware that color vision abnormality can be the first and predominant symptom of HELLP-related serous retinal detachment. © 2015 Japan Society of Obstetrics and Gynecology.

  11. Studies on the role of goat heart galectin-1 as an erythrocyte membrane perturbing agent

    PubMed Central

    Ashraf, Ghulam Md; Perveen, Asma; Zaidi, Syed Kashif; Tabrez, Shams; Kamal, Mohammad A.; Banu, Naheed

    2014-01-01

    Galectins are β-galactoside binding lectins with a potential hemolytic role on erythrocyte membrane integrity and permeability. In the present study, goat heart galectin-1 (GHG-1) was purified and investigated for its hemolytic actions on erythrocyte membrane. When exposed to various saccharides, lactose and sucrose provided maximum protection against hemolysis, while glucose and galactose provided lesser protection against hemolysis. GHG-1 agglutinated erythrocytes were found to be significantly hemolyzed in comparison with unagglutinated erythrocytes. A concentration dependent rise in the hemolysis of trypsinized rabbit erythrocytes was observed in the presence of GHG-1. Similarly, a temperature dependent gradual increase in percent hemolysis was observed in GHG-1 agglutinated erythrocytes as compared to negligible hemolysis in unagglutinated cells. The hemolysis of GHG-1 treated erythrocytes showed a sharp rise with the increasing pH up to 7.5 which became constant till pH 9.5. The extent of erythrocyte hemolysis increased with the increase in the incubation period, with maximum hemolysis after 5 h of incubation. The results of this study establish the ability of galectins as a potential hemolytic agent of erythrocyte membrane, which in turn opens an interesting avenue in the field of proteomics and glycobiology. PMID:25561893

  12. Studies on the role of goat heart galectin-1 as an erythrocyte membrane perturbing agent.

    PubMed

    Ashraf, Ghulam Md; Perveen, Asma; Zaidi, Syed Kashif; Tabrez, Shams; Kamal, Mohammad A; Banu, Naheed

    2015-01-01

    Galectins are β-galactoside binding lectins with a potential hemolytic role on erythrocyte membrane integrity and permeability. In the present study, goat heart galectin-1 (GHG-1) was purified and investigated for its hemolytic actions on erythrocyte membrane. When exposed to various saccharides, lactose and sucrose provided maximum protection against hemolysis, while glucose and galactose provided lesser protection against hemolysis. GHG-1 agglutinated erythrocytes were found to be significantly hemolyzed in comparison with unagglutinated erythrocytes. A concentration dependent rise in the hemolysis of trypsinized rabbit erythrocytes was observed in the presence of GHG-1. Similarly, a temperature dependent gradual increase in percent hemolysis was observed in GHG-1 agglutinated erythrocytes as compared to negligible hemolysis in unagglutinated cells. The hemolysis of GHG-1 treated erythrocytes showed a sharp rise with the increasing pH up to 7.5 which became constant till pH 9.5. The extent of erythrocyte hemolysis increased with the increase in the incubation period, with maximum hemolysis after 5 h of incubation. The results of this study establish the ability of galectins as a potential hemolytic agent of erythrocyte membrane, which in turn opens an interesting avenue in the field of proteomics and glycobiology.

  13. Evidence of ATP assay as an appropriate alternative of MTT assay for cytotoxicity of secondary effluents from WWTPs.

    PubMed

    Yang, Yang; Lu, Yun; Wu, Qian-Yuan; Hu, Hong-Ying; Chen, Ying-Hua; Liu, Wan-Li

    2015-12-01

    Biological tests are effective and comprehensive methods to assess toxicity of environmental pollutants to ensure the safety of reclaimed water. In this study, the canonical MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was performed to evaluate the cytotoxicity of dissolved organic matters (DOMs) of secondary effluents from wastewater treatment plants (WWTPs). It was surprising that most concentrated DOMs treated HepG2 cells yielded much higher signal compared with vehicle control regardless of difference of treatment technologies and seasons. However, there was actually no obvious enhancement of the cell proliferation by microscopy. In order to find out potential reason for the discrepancy, another three assays were performed. The results of ATP assay and flow cytometry showed expected toxicity, which was consistent with microscopy and previous studies, while DNA assay did not exhibit apparent change in treated cells. The possible mechanisms of abnormal MTT signal could be that some materials in secondary effluents isolated by solid extraction with HLB resin directly reacted with MTT and/or enhanced the activity of mitochondrial dehydrogenase. Therefore, the MTT assay is not suitable to assess cytotoxicity of complex mixtures such as secondary effluents, while ATP assay is an optional sensitive method. This study also suggests the importance of choosing both suitable extraction methods and detection assays for toxicity evaluation of component-unknown environmental samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Recombinase Polymerase Amplification-Based Assay to Diagnose Giardia in Stool Samples

    PubMed Central

    Crannell, Zachary Austin; Cabada, Miguel Mauricio; Castellanos-Gonzalez, Alejandro; Irani, Ayesha; White, Arthur Clinton; Richards-Kortum, Rebecca

    2015-01-01

    Giardia duodenalis is one of the most commonly identified parasites in stool samples. Although relatively easy to treat, giardiasis can be difficult to detect as it presents similar to other diarrheal diseases. Here, we present a recombinase polymerase amplification-based Giardia (RPAG) assay to detect the presence of Giardia in stool samples. The RPAG assay was characterized on the bench top using stool samples spiked with Giardia cysts where it showed a limit-of-detection nearly as low as the gold standard polymerase chain reaction assay. The RPAG assay was then tested in the highlands of Peru on 104 stool samples collected from the surrounding communities where it showed 73% sensitivity and 95% specificity against a polymerase chain reaction and microscopy composite gold standard. Further improvements in clinical sensitivity will be needed for the RPAG assay to have clinical relevance. PMID:25510713

  15. In vitro antioxidant and antiproliferative activities of selenium-containing phycocyanin from selenium-enriched Spirulina platensis.

    PubMed

    Chen, Tianfeng; Wong, Yum-Shing

    2008-06-25

    Both selenium and phycocyanin have been reported to show potent cancer chemopreventive activities. In this study, we investigated the in vitro antioxidant and antiproliferative activities of selenium-containing phycocyanin (Se-PC) purified from selenium-enriched Spirulina platensis. The antioxidant activity of Se-PC was evaluated by using four different free radical scavenging assays, namely, the 2,2'-azinobis-3-ethylbenzothiazolin-6-sulfonic acid (ABTS) assay, 1,1-diphenyl-2-picryhydrazyl (DPPH) assay, superoxide anion scavenging assay, and erythrocyte hemolysis assay. The results indicated that Se-PC exhibited stronger antioxidant activity than phycocyanin by scavenging ABTS, DPPH, superoxide anion, and 2,2'-azobis-(2-amidinopropane)dihydrochloride free radicals. Se-PC also showed dose-dependent protective effects on erythrocytes against H 2O 2-induced oxidative DNA damage as evaluated by the Comet assay. Moreover, Se-PC was identified as a potent antiproliferative agent against human melanoma A375 cells and human breast adenocarcinoma MCF-7 cells. Induction of apoptosis in both A375 and MCF-7 cells by Se-PC was evidenced by accumulation of sub-G1 cell populations, DNA fragmentation, and nuclear condensation. Further investigation on intracellular mechanisms indicated that depletion of mitochondrial membrane potential (DeltaPsi m) was involved in Se-PC-induced cell apoptosis. Our findings suggest that Se-PC is a promising organic Se species with potential applications in cancer chemoprevention.

  16. Genotoxicity of cadmium chloride in the marine gastropod Nerita chamaeleon using comet assay and alkaline unwinding assay.

    PubMed

    Sarkar, Anupam; Bhagat, Jacky; Ingole, Baban S; Rao, Durga P; Markad, Vijaykumar L

    2015-02-01

    This paper presents an evaluation of the genotoxic effects of cadmium chloride (CdCl2 ) on marine gastropod, Nerita chamaeleon following the technique of comet assay and the DNA alkaline unwinding assay (DAUA). In this study, the extent of DNA damage in gill cells of N. chamaeleon was measured after in vivo exposure to four different concentrations (10, 25, 50, and 75 µg/L) of CdCl2 . In vitro exposure of hydrogen peroxide (H2 O2 ; 1, 10, 25, and 50 µM) of the gill cells showed a significant increase in the percentage tail DNA, Olive tail moment, and tail length (TL). Significant changes in percentage tail DNA by CdCl2 exposure were observed in all exposed groups of snails with respect to those in control. Exposure to 75 µg/L of CdCl2 produced significant decrease in DNA integrity as measured by DAUA at all duration with respect to control. In vivo exposure to different concentrations of CdCl2 (10, 25, 50, and 75 µg/L) to N. chamaeleon showed considerable increase in DNA damage as observed by both alkaline comet assay and the DAUA. The extent of DNA damage in marine gastropods determined by the application of alkaline comet assay and DAUA clearly indicated the genotoxic responses of marine gastropod, N. chamaeleon to a wide range of cadmium concentration in the marine environment. © 2013 Wiley Periodicals, Inc.

  17. Reduction-responsive multifunctional hyperbranched polyaminoglycosides with excellent antibacterial activity, biocompatibility and gene transfection capability.

    PubMed

    Huang, Yajun; Ding, Xiaokang; Qi, Yu; Yu, Bingran; Xu, Fu-Jian

    2016-11-01

    There is an increasing demand in developing of multifunctional materials with good antibacterial activity, biocompatibility and drug/gene delivery capability for next-generation biomedical applications. To achieve this purpose, in this work series of hydroxyl-rich hyperbranched polyaminoglycosides of gentamicin, tobramycin, and neomycin (HP and SS-HP with redox-responsive disulfide bonds) were readily synthesized via ring-opening reactions in a one-pot manner. Both HP and SS-HP exhibit high antibacterial activity toward Escherichia coli and Staphylococcus aureus. Meanwhile, the hemolysis assay of the above materials shows good biocompatibility. Moreover, SS-HPs show excellent gene transfection efficiency in vitro due to the breakdown of reduction-responsive disulfide bonds. For an in vivo anti-tumor assay, the SS-HP/p53 complexes exhibit potent inhibition capability to the growth of tumors. This study provides a promising approach for the design of next-generation multifunctional biomedical materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Tissue Adhesives for Battlefield Hemorrhage Control

    DTIC Science & Technology

    1996-04-01

    extremely high bioburden it is felt that a rapid elution of the CHX or antimicrobial could be advantages. It is this rapid dumping of the 8000 Mw film...absorbance of each test article solution was determined spectrophotometrically at 545 nm. Similarly, absorbances were recorded for the positive...used to calculate percent hemolysis for the test article . Results showed 0.0% hemolysis for both test #1 and test #2, with a mean hemolysis of 0.0

  19. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    PubMed

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  20. Multisite analytical evaluation of the Abbott ARCHITECT cyclosporine assay.

    PubMed

    Wallemacq, Pierre; Maine, Gregory T; Berg, Keith; Rosiere, Thomas; Marquet, Pierre; Aimo, Giuseppe; Mengozzi, Giulio; Young, Julianna; Wonigeit, Kurt; Kretschmer, Robert; Wermuth, Bendicht; Schmid, Rainer W

    2010-04-01

    The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated immunoassay with magnetic microparticles coated with anti-CsA antibody and an acridinium-CsA tracer. Imprecision testing at the 7 evaluation sites gave a range of total % coefficient of variations of 7.5%-12.2% at 87.5 ng/mL, 6.6%-14.3% at 411 ng/mL, and 5.2%-10.7% at 916 ng/mL. The lower limit of quantification ranged from 12 to 20 ng/mL. Purified CsA metabolites AM1, AM1c, AM4N, AM9, and AM19 were tested in whole blood by the ARCHITECT assay and showed minimal cross-reactivity at all 7 sites. In particular, AM1 and AM9 cross-reactivity in the ARCHITECT assay, ranged from -2.5% to 0.2% and -0.8% to 2.2%, respectively, and was significantly lower than for the TDx assay, in which the values were 3.2% and 16.1%, respectively. Comparable testing of metabolites in the Dade Dimension Xpand assay at 2 evaluation sites showed cross-reactivity to AM4N (6.4% and 6.8%) and AM9 (2.6% and 3.6%) and testing on the Roche Integra 800 showed cross-reactivity to AM1c (2.4%), AM9 (10.7%), and AM19 (2.8%). Cyclosporine International Proficiency Testing Scheme samples, consisting of both pooled specimens from patients receiving CsA therapy as well as whole-blood specimens supplemented with CsA, were tested by the ARCHITECT assay at 6 sites and showed an average bias of -24 to -58 ng/mL versus LC/MSMS CsA and -2 to -37 ng/mL versus AxSYM CsA. Studies were performed with the ARCHITECT CsA assay on patient specimens with the following results: ARCHITECT CsA assay versus LC/MSMS, average bias of 31 ng/mL; ARCHITECT versus the

  1. Recombinase polymerase amplification-based assay to diagnose Giardia in stool samples.

    PubMed

    Crannell, Zachary Austin; Cabada, Miguel Mauricio; Castellanos-Gonzalez, Alejandro; Irani, Ayesha; White, Arthur Clinton; Richards-Kortum, Rebecca

    2015-03-01

    Giardia duodenalis is one of the most commonly identified parasites in stool samples. Although relatively easy to treat, giardiasis can be difficult to detect as it presents similar to other diarrheal diseases. Here, we present a recombinase polymerase amplification-based Giardia (RPAG) assay to detect the presence of Giardia in stool samples. The RPAG assay was characterized on the bench top using stool samples spiked with Giardia cysts where it showed a limit-of-detection nearly as low as the gold standard polymerase chain reaction assay. The RPAG assay was then tested in the highlands of Peru on 104 stool samples collected from the surrounding communities where it showed 73% sensitivity and 95% specificity against a polymerase chain reaction and microscopy composite gold standard. Further improvements in clinical sensitivity will be needed for the RPAG assay to have clinical relevance. © The American Society of Tropical Medicine and Hygiene.

  2. Impact of assay design on test performance: lessons learned from 25-hydroxyvitamin D.

    PubMed

    Farrell, Christopher-John L; Soldo, Joshua; McWhinney, Brett; Bandodkar, Sushil; Herrmann, Markus

    2014-11-01

    Current automated immunoassays vary significantly in many aspects of their design. This study sought to establish if the theoretical advantages and disadvantages associated with different design formats of automated 25-hydroxyvitamin D (25-OHD) assays are translated into variations in assay performance in practice. 25-OHD was measured in 1236 samples using automated assays from Abbott, DiaSorin, Roche and Siemens. A subset of 362 samples had up to three liquid chromatography-tandem mass spectrometry 25-OHD analyses performed. 25-OHD₂ recovery, dilution recovery, human anti-animal antibody (HAAA) interference, 3-epi-25-OHD₃ cross-reactivity and precision of the automated assays were evaluated. The assay that combined release of 25-OHD with analyte capture in a single step showed the most accurate 25-OHD₂ recovery and the best dilution recovery. The use of vitamin D binding protein (DBP) as the capture moiety was associated with 25-OHD₂ under-recovery, a trend consistent with 3-epi-25-OHD₃ cross-reactivity and immunity to HAAA interference. Assays using animal-derived antibodies did not show 3-epi-25-OHD₃ cross-reactivity but were variably susceptible to HAAA interference. Not combining 25-OHD release and capture in one step and use of biotin-streptavidin interaction for solid phase separation were features of the assays with inferior accuracy for diluted samples. The assays that used a backfill assay format showed the best precision at high concentrations but this design did not guarantee precision at low 25-OHD concentrations. Variations in design among automated 25-OHD assays influence their performance characteristics. Consideration of the details of assay design is therefore important when selecting and validating new assays.

  3. Growth hormone: its measurement and the need for assay harmonization.

    PubMed

    Wood, P

    2001-09-01

    Serum human growth hormone (hGH) assays show a wide range in bias and in cut-off values for provocative tests, which vary from 13.5 to 35-40 mU/L when they have been established. Studies using novel hGH assays show that methods that are absolutely specific for 22-kDa hGH may not identify bioactive hGH peaks and that 20:22-kDa hGH ratios are increased in acromegaly. Greater harmonization of serum hGH methods can be achieved by: changing from IS 80/505 to IS 98/574, which is calibrated in mass units of recombinant 22-kDa hGH; using monoclonal/polyclonal or polyclonal/polyclonal antibody combinations that measure both 20-kDa and 22-kDa hGH; the development of assays such as the immunofunctional hGH assay which has the convenience of an immunometric assay but gives results that correlate better with bioassays collaboration between manufacturers and laboratories to establish method-related cut-off limits for provocative tests of hGH status.

  4. Comparison of KRAS genotype: therascreen assay vs. LNA-mediated qPCR clamping assay.

    PubMed

    Chang, Shao-Chun; Denne, Jonathan; Zhao, Luping; Horak, Christine; Green, George; Khambata-Ford, Shirin; Bray, Christopher; Celik, Ilhan; Van Cutsem, Eric; Harbison, Christopher

    2013-09-01

    Kirsten rat sarcoma virus (KRAS) wild-type status determined using a locked nucleic acid (LNA)-mediated quantitative polymerase chain reaction (qPCR) clamping assay (LNA assay) predicted response to therapy in the CRYSTAL (Cetuximab Combined With Irinotecan in First-Line Therapy for Metastatic Colorectal Cancer) study. A companion KRAS diagnostic tool has been developed for routine clinical use (QIAGEN therascreen kit) (QIAGEN Manchester Ltd, Manchester, UK). We wanted to assess the concordance between the validated US Food and Drug Administration (FDA)-approved therascreen assay and the LNA assay in determining the KRAS status of a subset of patients enrolled in the CRYSTAL study. DNA extracted from paraffin-embedded tumor sections was tested for KRAS status using the therascreen assay. Efficacy data from the CRYSTAL study were assessed to determine if the overall survival (OS) hazard ratio for cetuximab in patients identified as having KRAS wild-type status using the therascreen assay was equivalent to that in patients identified as KRAS wild-type using the LNA assay. This was determined by assessing if the concordance between the therascreen assay and the LNA assay met the minimum threshold (prespecified as 0.8) to achieve a significant difference in the OS hazard ratio in favor of the cetuximab + FOLFIRI (5-fluorouracil, leucovorin [folinic acid], irinotecan) arm in the KRAS wild-type population as identified using the therascreen assay. Of the 148 samples determined to be KRAS wild-type (therascreen assay), 141 (95.3%) samples were also KRAS wild-type (LNA assay) and 7 samples (4.7%) were KRAS mutant (LNA assay). The prespecified primary concordance measure p was 141/148 = 0.953 (95% confidence interval [CI], 0.905-0.981). The concordance was statistically significantly higher than the prespecified threshold of 0.8 for concordance between the therascreen assay and the LNA assay. Consistent with the concordance exceeding the prespecified threshold, the OS

  5. A single secreted luciferase-based gene reporter assay.

    PubMed

    Barriscale, Kathy A; O'Sullivan, Sharon A; McCarthy, Tommie V

    2014-05-15

    Promoter analysis typically employs a reporter gene fused to a test promoter combined with a second reporter fused to a control promoter that is used for normalization purposes. However, this approach is not valid when experimental conditions affect the control promoter. We have developed and validated a single secreted luciferase reporter (SSLR) assay for promoter analysis that avoids the use of a control reporter. The approach uses an early level of expression of a secreted luciferase linked to a test promoter as an internal normalization control for subsequent analysis of the same promoter. Comparison of the SSLR assay with the dual luciferase reporter (DLR) assay using HMGCR (3-hydroxy-3-methylglutaryl-coenzyme A reductase) and LDLR (low-density lipoprotein receptor) promoter constructs, which are down-regulated by 25-hydroxycholesterol, show that both assays yield similar results. Comparison of the response of the HMGCR promoter in SSLR transient assays compared very favorably with the response of the same promoter in the stable cell line. Overall, the SSLR assay proved to be a valid alternative to the DLR assay for certain applications and had significant advantages in that measurement of only one luciferase is required and monitoring can be continuous because cell lysis is not necessary. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Qualification of a select one-stage activated partial thromboplastin time-based clotting assay and two chromogenic assays for the post-administration monitoring of nonacog beta pegol.

    PubMed

    Tiefenbacher, S; Bohra, R; Amiral, J; Bowyer, A; Kitchen, S; Lochu, A; Rosén, S; Ezban, M

    2017-10-01

    Essentials Nonacog beta pegol (N9-GP) is an extended half-life, recombinant human factor IX (FIX). One-stage clotting (OSC) and chromogenic FIX activity assays were assessed for N9-GP recovery. OSC STA ® -Cephascreen ® , ROX FIX and BIOPHEN FIX chromogenic assays were qualified for N9-GP. Other extended half-life factor products should be assessed in a similar way prior to approval. Background Nonacog beta pegol (N9-GP) is an extended half-life, glycoPEGylated recombinant human factor IX that is under development for the prophylaxis and treatment of bleeding episodes in hemophilia B patients. Considerable reagent-dependent variability has been observed when one-stage clotting assays are used to measure the recovery of recombinant FIX products, including N9-GP. Objective To qualify select one-stage clotting and chromogenic FIX activity assays for measuring N9-GP recovery. Methods The accuracy and precision of the one-stage clotting assay (with the STA-Cephascreen activated partial thromboplastin [APTT] reagent) and the ROX Factor IX and BIOPHEN Factor IX chromogenic assays for measuring N9-GP recovery were assessed in N9-GP-spiked hemophilia B plasma samples in a systematic manner at three independent sites, with manufacturer-recommended protocols and/or site-specific assay setups, including different instruments. Results For each of the three FIX activity assays qualified on five different reagent-instrument systems, acceptable intra-assay and interassay accuracy and precision, dilution integrity, reagent robustness and freeze-thaw and short-term sample stabilities were demonstrated. The STA-Cephascreen assay showed a limited reportable range at one of the three qualification sites, and the BIOPHEN Factor IX assay showed suspect low-end sensitivity at one of the three qualification sites. An individual laboratory would account for these limitations by adjusting the assay's reportable range; thus, these findings are not considered to impact the respective

  7. The role of counterions in the membrane-disruptive properties of pH-sensitive lysine-based surfactants.

    PubMed

    Nogueira, D R; Mitjans, M; Infante, M R; Vinardell, M P

    2011-07-01

    Surfactants are among the most versatile and widely used excipients in pharmaceuticals. This versatility, together with their pH-responsive membrane-disruptive activity and low toxicity, could also enable their potential application in drug delivery systems. Five anionic lysine-based surfactants which differ in the nature of their counterion were studied. Their capacity to disrupt the cell membrane was examined under a range of pH values, concentrations and incubation times, using a standard hemolysis assay as a model for endosomal membranes. The surfactants showed pH-sensitive hemolytic activity and improved kinetics at the endosomal pH range. Low concentrations resulted in negligible hemolysis at physiological pH and high membrane lytic activity at pH 5.4, which is in the range characteristic of late endosomes. With increasing concentration, the surfactants showed an enhanced capacity to lyse cell membranes, and also caused significant membrane disruption at physiological pH. This observation indicates that, at high concentrations, surfactant behavior is independent of pH. The mechanism of surfactant-mediated membrane destabilization was addressed, and scanning electron microscopy studies were also performed to evaluate the effects of the compounds on erythrocyte morphology as a function of pH. The in vitro cytotoxicity of the surfactants was assessed by MTT and NRU assays with the 3T3 cell line. The influence of different types of counterion on hemolytic activity and the potential applications of these surfactants in drug delivery are discussed. The possibility of using pH-sensitive surfactants for endosome disruption could hold great promise for intracellular drug delivery systems in future therapeutic applications. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  8. European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-07-01

    The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.

  9. Performance characteristics of the ARCHITECT anti-HCV assay.

    PubMed

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  10. Spiral Salmonella assay: validation against the standard pour-plate assay.

    PubMed

    Diehl, M; Fort, F

    1996-01-01

    The spiral Ames assay, an automated approach to bacterial mutagenicity testing which simplifies the test procedure and reduces the amount of drug required to generate mutagenic dose-response information, has been evaluated and validated for routine screening. The spiral plater delivers the Salmonella bacteria, exogenous metabolic activation system and drug to the surface of a rotating agar plate one on top of another in such a way that a uniform density of bacteria is exposed to a logarithmically decreasing volume of drug. Following an incubation of 48 hr at 37 degrees C, the plates are scanned by a laser counter, and the data are subjected to a computerized analysis. Petri plates of 15 cm diameter were used to provide a concentration range of about 250-fold per plate. The Salmonella were concentrated 20-fold to increase sensitivity. Thirty-eight compounds from a variety of chemical classes, including both pharmaceuticals and known mutagens of moderate to strong potency, were tested in both the spiral and the standard pour-plate assays. There was overall test agreement on positive or negative results for 82% of the compounds tested. When only the results from strains TA98 plus TA100 were considered, the agreement was 87%. When positive results were obtained, the fold increase over vehicle control was on average twice as great for the spiral assay compared to the pour-plate assay. It was concluded that the two assay procedures generally provided comparable results, with the spiral assay being somewhat more sensitive in terms of dose-response than the pour-plate assay.

  11. Bovine Serum Albumin Nanoparticles Containing Amphotericin B: Characterization, Cytotoxicity and In Vitro Antifungal Evaluation.

    PubMed

    Casa, Diani Meza; Karam, Thaysa Ksiaskiewcz; Alves, Aline de Cristo Soares; Zgoda, Aline Aparecida; Khalil, Najeh Maissar; Mainardes, Rubiana Mara

    2015-12-01

    In this study, nanoparticles based on bovine serum albumin (BSA) containing amphotericin B (AmB) were obtained by the desolvation method and characterized with respect to size, size distribution, AmB encapsulation efficiency, AmB state of aggregation, and AmB in vitro release profile. After, the effect of nanoparticles on the cytotoxicity of human erythrocytes in vitro and efficacy over strains of Candida spp. were evaluated. The mean particle size was 156 nm and the AmB encapsulation efficiency was over 82%. The in vitro release profile revealed a sustained release of approximately 48% of AmB over 5 days. AmB is present in BSA nanoparticles as monomer. AmB-loaded nanoparticles showed very low index of hemolysis (less than 8%) in 72 h of assay compared to free AmB, which presented 100% of hemolysis in 2 h of incubation. The AmB-loaded BSA nanoparticles were as effective as free AmB against Candida albicans and Candida tropicalis, considering their sustained release profile. Thus, BSA nanoparticles are potential carriers for AmB, reducing its molecular aggregation and prolonging its release, resulting in lower cytotoxicity while maintaining its antifungal activity.

  12. Preparation of anionic polyurethane nanoparticles and blood compatible behaviors.

    PubMed

    Zhu, Qinshu; Wang, Yan; Zhou, Min; Mao, Chun; Huang, Xiaohua; Bao, Jianchun; Shen, Jian

    2012-05-01

    The anionic polyurethane nanoparticles (APU-NPs) were obtained by an emulsion polymerization method. It was found that the average size of the prepared APU-NPs is about 84 nm, and the APU-NPs have zeta-potential of -38.9 mV. The bulk characterization of synthesized APU-NPs was investigated by FTIR. The blood compatibility of APU-NPs was characterized by in vitro for coagulation tests, complement activation, platelet activation, cytotoxicity experiments, and hemolysis assay. The results showed that the APU-NPs synthesized in this paper are blood compatible with low level of cell cytotoxicity, and the results were significant for their potential use in vivo.

  13. Transfusion of human volunteers with older, stored red blood cells produces extravascular hemolysis and circulating non–transferrin-bound iron

    PubMed Central

    Brittenham, Gary M.; Billote, Genia B.; Francis, Richard O.; Ginzburg, Yelena Z.; Hendrickson, Jeanne E.; Jhang, Jeffrey; Schwartz, Joseph; Sharma, Shruti; Sheth, Sujit; Sireci, Anthony N.; Stephens, Hannah L.; Stotler, Brie A.; Wojczyk, Boguslaw S.; Zimring, James C.; Spitalnik, Steven L.

    2011-01-01

    Transfusions of RBCs stored for longer durations are associated with adverse effects in hospitalized patients. We prospectively studied 14 healthy human volunteers who donated standard leuko-reduced, double RBC units. One unit was autologously transfused “fresh” (3-7 days of storage), and the other “older” unit was transfused after 40 to 42 days of storage. Of the routine laboratory parameters measured at defined times surrounding transfusion, significant differences between fresh and older transfusions were only observed in iron parameters and markers of extravascular hemolysis. Compared with fresh RBCs, mean serum total bilirubin increased by 0.55 mg/dL at 4 hours after transfusion of older RBCs (P = .0003), without significant changes in haptoglobin or lactate dehydrogenase. In addition, only after the older transfusion, transferrin saturation increased progressively over 4 hours to a mean of 64%, and non–transferrin-bound iron appeared, reaching a mean of 3.2μM. The increased concentrations of non–transferrin-bound iron correlated with enhanced proliferation in vitro of a pathogenic strain of Escherichia coli (r = 0.94, P = .002). Therefore, circulating non–transferrin-bound iron derived from rapid clearance of transfused, older stored RBCs may enhance transfusion-related complications, such as infection. The trial was registered with www.clinicaltrials.gov as #NCT01319552. PMID:22021369

  14. Bovine Papillomavirus Clastogenic Effect Analyzed in Comet Assay

    PubMed Central

    Araldi, R. P.; Melo, T. C.; Diniz, N.; Mazzuchelli-de-Souza, J.; Carvalho, R. F.; Beçak, W.; Stocco, R. C.

    2013-01-01

    Bovine papillomavirus (BPV) is an oncogenic virus related to serious livestock diseases. Oncoproteins encoded by BPV are involved in several steps of cellular transformation and have been reported as presenting clastogenic effects in peripheral lymphocytes and primary culture cells. The aim of this study was to evaluate the clastogenic potential of BPV types 1, 2, and 4 by comet assay. Peripheral blood was collected from 37 bovines, 32 infected with different levels of papillomatosis (12 animals have no affection) and five calves, virus free (negative control). The viral identification showed presence of more than one virus type in 59.375% of the infected animals. Comet assay was performed according to alkaline technique. The Kruskal-Wallis test showed statistical difference between the negative control group and infected animals (P = 0.0015). The Dunn post hoc test showed difference comparing the infected animals with calves. Mann-Whitney U test verified no difference between animals infected with only one viral type and animals presenting more than one viral type. The comet assay is considered an efficient tool for assessment of damage in the host chromatin due to viral action, specifically highlighting viral activity in blood cells. PMID:23956996

  15. Rapid body mass loss affects erythropoiesis and hemolysis but does not impair aerobic performance in combat athletes.

    PubMed

    Reljic, D; Feist, J; Jost, J; Kieser, M; Friedmann-Bette, B

    2016-05-01

    Rapid body mass loss (RBML) before competition was found to decrease hemoglobin mass (Hbmass ) in elite boxers. This study aimed to investigate the underlying mechanisms of this observation. Fourteen well-trained combat athletes who reduced body mass before competitions (weight loss group, WLG) and 14 combat athletes who did not practice RBML (control group, CON) were tested during an ordinary training period (t-1), 1-2 days before an official competition (after 5-7 days RBML in WLG, t-2), and after a post-competition period (t-3). In WLG, body mass (-5.5%, range: 2.9-6.8 kg) and Hbmass (-4.1%) were significantly (P < 0.001) reduced after RBML and were still decreased by 1.6% (P < 0.05) and 2.6% (P < 0.001) at t-3 compared with t-1. After RBML, erythropoietin, reticulocytes, haptoglobin, triiodothyronine (FT3 ), and free androgen index (FAI) were decreased compared with t-1 and t-3. An increase occurred in ferritin and bilirubin. Peak treadmill-running performance and VO2peak did not change significantly, but performance at 4-mmol lactate threshold was higher after RBML (P < 0.05). In CON, no significant changes were found in any parameter. Apparently, the significant decrease in Hbmass after RBML in combat athletes was caused by impaired erythropoiesis and increased hemolysis without significant impact on aerobic performance capacity. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Using the CPTAC Assay Portal to identify and implement highly characterized targeted proteomics assays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whiteaker, Jeffrey R.; Halusa, Goran; Hoofnagle, Andrew N.

    2016-02-12

    The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative tomore » other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and post-translational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.« less

  17. Using the CPTAC Assay Portal to Identify and Implement Highly Characterized Targeted Proteomics Assays.

    PubMed

    Whiteaker, Jeffrey R; Halusa, Goran N; Hoofnagle, Andrew N; Sharma, Vagisha; MacLean, Brendan; Yan, Ping; Wrobel, John A; Kennedy, Jacob; Mani, D R; Zimmerman, Lisa J; Meyer, Matthew R; Mesri, Mehdi; Boja, Emily; Carr, Steven A; Chan, Daniel W; Chen, Xian; Chen, Jing; Davies, Sherri R; Ellis, Matthew J C; Fenyö, David; Hiltke, Tara; Ketchum, Karen A; Kinsinger, Chris; Kuhn, Eric; Liebler, Daniel C; Liu, Tao; Loss, Michael; MacCoss, Michael J; Qian, Wei-Jun; Rivers, Robert; Rodland, Karin D; Ruggles, Kelly V; Scott, Mitchell G; Smith, Richard D; Thomas, Stefani; Townsend, R Reid; Whiteley, Gordon; Wu, Chaochao; Zhang, Hui; Zhang, Zhen; Rodriguez, Henry; Paulovich, Amanda G

    2016-01-01

    The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as an open-source repository of well-characterized targeted proteomic assays. The portal is designed to curate and disseminate highly characterized, targeted mass spectrometry (MS)-based assays by providing detailed assay performance characterization data, standard operating procedures, and access to reagents. Assay content is accessed via the portal through queries to find assays targeting proteins associated with specific cellular pathways, protein complexes, or specific chromosomal regions. The position of the peptide analytes for which there are available assays are mapped relative to other features of interest in the protein, such as sequence domains, isoforms, single nucleotide polymorphisms, and posttranslational modifications. The overarching goals are to enable robust quantification of all human proteins and to standardize the quantification of targeted MS-based assays to ultimately enable harmonization of results over time and across laboratories.

  18. Development of an enzyme-linked immunosorbent assay and a beta-1 adrenergic receptor-based assay for monitoring the drug atenolol.

    PubMed

    Sapir, A; Shalev, A Hariton; Skalka, N; Bronshtein, A; Altstein, M

    2013-03-01

    Two approaches for monitoring atenolol (ATL) were applied: an immunochemical assay and a competitive-binding assay, based on the interaction between ATL and its target receptor, β1 adrenergic receptor (β1AR). Polyclonal antibodies (Abs) for ATL were generated, and a highly specific microplate immunochemical assay, that is, an enzyme-linked immunosorbent assay (ELISA), for its detection was developed. The ATL ELISA exhibited I50 and limit of detection (I20) values of 0.15 ± 0.048 and 0.032 ± 0.016 ng/ml, respectively, and the Abs did not cross-react with any of the tested beta-blocker drugs. Furthermore, a human β1AR (h-β1AR) was stably expressed in Spodoptera frugiperda cells (Sf9). The receptor was employed to develop a competitive-binding assay that monitored binding of ATL in the presence of isoproteranol by quantification of secondary messenger, cyclic adenosine monophosphate (cAMP), levels in the transfected cells. The assay showed that the recombinant h-β1AR was functional, could bind the agonistic ligand isoproterenol as well as the antagonist ATL, as indicated by a dose-dependent elevation of cAMP in the presence of isoproteranol, and decrease after ATL addition. The highly efficient and sensitive ELISA and the receptor assay represent two methods suitable for efficient and cost-effective large-scale, high-throughput monitoring of ATL in environmental, agricultural, and biological samples. Copyright © 2012 SETAC.

  19. Development of novel assays for lignin degradation: comparative analysis of bacterial and fungal lignin degraders.

    PubMed

    Ahmad, Mark; Taylor, Charles R; Pink, David; Burton, Kerry; Eastwood, Daniel; Bending, Gary D; Bugg, Timothy D H

    2010-05-01

    Two spectrophotometric assays have been developed to monitor breakdown of the lignin component of plant lignocellulose: a continuous fluorescent assay involving fluorescently modified lignin, and a UV-vis assay involving chemically nitrated lignin. These assays have been used to analyse lignin degradation activity in bacterial and fungal lignin degraders, and to identify additional soil bacteria that show activity for lignin degradation. Two soil bacteria known to act as aromatic degraders, Pseudomonas putida and Rhodococcus sp. RHA1, consistently showed activity in these assays, and these strains were shown in a small scale experiment to breakdown lignocellulose, producing a number of monocyclic phenolic products. Using milled wood lignin prepared from wheat straw, pine, and miscanthus, some bacterial lignin degraders were found to show specificity for lignin type. These assays could be used to identify novel lignin degraders for breakdown of plant lignocellulose.

  20. Development and Evaluation of a Blocking Enzyme-Linked Immunosorbent Assay and Virus Neutralization Assay To Detect Antibodies to Viral Hemorrhagic Septicemia Virus

    PubMed Central

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV. PMID:24429071

  1. Development and evaluation of a blocking enzyme-linked immunosorbent assay and virus neutralization assay to detect antibodies to viral hemorrhagic septicemia virus

    USGS Publications Warehouse

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas M.; Toohey-Kurth, Kathy

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV.

  2. INITIAL OBSERVATIONS ON THE EFFECT OF HYPOBARIC AND HYPERBARIC PRESSURE ON CELL PERMEABILITY.

    DTIC Science & Technology

    erythrocytes in hypotonic saline at hypobaric and hyperbaric pressures showed an increase and decrease, respectively, in the extent of hemolysis when...resulted in an apparent alteration in the mechanics of solvent exchange or cell permeability, or both. Comparison of the relative hemolysis of human

  3. Comparison of the Simplexa™ Flu A/B & RSV kit (nucleic acid extraction-dependent assay) and the Prodessa ProFlu+™ assay for detecting influenza and respiratory syncytial viruses.

    PubMed

    Selvaraju, Suresh B; Bambach, Adrienne V; Leber, Amy L; Patru, Maria-Magdalena; Patel, Anami; Menegus, Marilyn A

    2014-09-01

    The relative performance of 2 widely used reverse transcription polymerase chain reaction (RT-PCR) assays, the Focus diagnostics Simplexa™ Flu A/B & RSV kit (nucleic acid extraction-dependent assay) and the Prodessa Proflu+™ assay, was evaluated using 735 prospectively and retrospectively collected nasopharyngeal swab specimens. Overall, the assays showed positive and negative agreements of 100% and 99.7% for influenza A, 98.1% and 99.9% for influenza B, and 99.3% and 99.5% for respiratory syncytial virus. The relative analytical sensitivity of the 2 assays was also similar. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The narrow therapeutic window of glycated hemoglobin and assay variability.

    PubMed

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  5. Cytogenetic status of healthy children assessed with the alkaline comet assay and the cytokinesis-block micronucleus cytome assay.

    PubMed

    Gajski, Goran; Gerić, Marko; Oreščanin, Višnja; Garaj-Vrhovac, Vera

    2013-01-20

    In the present study the alkaline comet assay and the cytokinesis-block micronucleus cytome (CBMN Cyt) assay were used to evaluate the baseline frequency of cytogenetic damage in peripheral blood lymphocytes (PBLs) of 50 healthy children from the general population in Croatia (age, 11.62±1.81 years). Mean values of tail length, tail intensity and tail moment, as comet assay parameters, were 12.92±0.10, 0.73±0.06 and 0.08±0.01, respectively. The mean frequency of micronuclei (MN) for all subjects was 2.32±0.28 per 1000 bi-nucleated cells, while the mean frequency of nucleoplasmic bridges (NPBs) was 1.72±0.24 and of nuclear buds (NBUDs) 1.44±0.19. The mean nuclear division index (NDI) was 1.70±0.05. When comet-assay parameters were considered, higher mean values for all three were found for the female population. According to the Mann-Whitney U test applied on the results of the comet assay, the only statistically significant difference between the male and female populations was found for tail length. Similar to the results obtained by the comet assay, girls showed higher mean values of all three measured parameters of the CBMN Cyt assay. This difference was statistically significant for total number of NPBs only. In the case of the NDI, a higher mean value was also obtained in girls, but this difference was not statistically significant. The results obtained present background data that could be considered as normal values for healthy children living in urban areas, and can later on serve as baseline values for further toxicological monitoring. Additionally, the usefulness of both techniques in measuring cytogenetic damage during bio-monitoring of children is confirmed. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. A European multicenter study on the analytical performance of the VERIS HBV assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Homogeneous screening assay for human tankyrase.

    PubMed

    Narwal, Mohit; Fallarero, Adyary; Vuorela, Pia; Lehtiö, Lari

    2012-06-01

    Tankyrase, a member of human PARP protein superfamily, catalyzes a covalent post-translational modification of substrate proteins. This modification, poly(ADP-ribos)ylation, leads to changes in protein interactions and modifies downstream signaling events. Tankyrase 1 is a potential drug target due to its functions in telomere homeostasis and in Wnt signaling. We describe here optimization and application of an activity-based homogenous assay for tankyrase inhibitors in a high-throughput screening format. The method measures the consumption of substrate by the chemical conversion of the remaining NAD(+) into a stable fluorescent condensation product. Conditions were optimized to measure the enzymatic auto-modification of a recombinant catalytic fragment of tankyrase 1. The fluorescence assay is inexpensive, operationally easy and performs well according to the statistical analysis (Z'= 0.7). A validatory screen with a natural product library confirmed suitability of the assay for finding new tankyrase inhibitors. Flavone was the most potent (IC(50)=325 nM) hit from the natural compounds. A flavone derivative, apigenin, and isopropyl gallate showed potency on the micromolar range, but displayed over 30-fold selectivity for tankyrase over the studied isoenzymes PARP1 and PARP2. The assay is robust and will be useful for screening new tankyrase inhibitors.

  8. Postpartum plasma exchange in a woman with suspected thrombotic thrombocytopenic purpura (TTP) vs. hemolysis, elevated liver enzymes, and low platelet syndrome (HELLP): a case study.

    PubMed

    Myers, Linda

    2010-01-01

    The occurrence of a hypercoagulable state and decreasing concentration of ADAMTS 13 in late pregnancy and during the postpartum period increases the risk for a woman to develop life-threatening thrombotic thrombocytopenic purpura (TTP). This is also the time of great risk for the more common obstetric complications of preeclampsia; eclampsia; and hemolysis, elevated liver functions tests, low platelets (HELLP) syndrome. These conditions are associated with high maternal and perinatal mortality. Differential diagnosis may be difficult due to the overlapping of clinical and laboratory findings, including thrombocytopenia, microangiopathic hemolytic anemia, neurologic symptoms, and renal insufficiency, making it difficult or impossible to distinguish them from TTP. Management of microangiopathic disorders encountered during pregnancy differ; therefore, an accurate diagnosis is required. Outcomes of TTP without plasma exchange therapy (TPE) are almost uniformly fatal. Early recognition and management of symptoms with prompt and aggressive TPE is essential when TTP is suspected.

  9. Development of a F actin-based live-cell fluorimetric microplate assay for diarrhetic shellfish toxins.

    PubMed

    Leira, F; Alvarez, C; Cabado, A G; Vieites, J M; Vieytes, M R; Botana, L M

    2003-06-15

    A new cytotoxicity assay for detection and quantitation of diarrhetic shellfish toxins (DSP) is presented. This assay is based upon fluorimetric determination of F-actin depolymerization induced by okadaic acid (OA)-class compounds in the BE(2)-M17 neuroblastoma cell line. No interferences were observed with other marine toxins such as saxitoxin, domoic acid, or yessotoxin, thus indicating a good specificity of the assay as expected by the direct relationship between protein phosphatase inhibition and cytoskeletal changes. The proposed method is rapid (<2h) and shows a linear response in the range of 50-300 nM OA. The detection limit of the assay for crude methanolic extracts of bivalves lies between 0.2 and 1.0 microg OA per gram of digestive glands, depending on the type of samples (fresh or canned), thus being similar to that of the mouse bioassay. The performance of this assay has been evaluated by comparative analysis of 32 toxic mussel samples by the F-actin assay, mouse bioassay, HPLC and PP2A inhibition assay. Results obtained by the F-actin method showed no differences with HPLC and significant correlation with PP2A inhibition assay (r(2)=0.71). No false negative results were obtained with this new cell assay, which also showed optimum reproducibility.

  10. Cost of gentamicin assays carried out by microbiology laboratories.

    PubMed Central

    Vacani, P F; Malek, M M; Davey, P G

    1993-01-01

    AIMS--To assess the current range of prices charged for gentamicin assays in United Kingdom laboratories; and to examine the laboratories' likely response to increases or decreases in the demand for the service. METHODS--A postal survey of the 420 members of the Association of Medical Microbiologists was used to establish the range of prices charged for aminoglycoside assays. Additionally, eight private institutions were contacted to determine what the private sector was charging for aminoglycoside assays. Reagent costs in the NHS laboratories were calculated by dividing the total cost of all aminoglycoside assay kits by the number of samples analysed. RESULTS--The NHS and the private institutions both showed a wide price variation. Prices charged to an in-hospital requester for a peak and trough assay ranged from 5.00 pounds to 68.20 pounds (n = 44), and to an external private hospital, under a bulk service contract, from 5.00 pounds to 96.00 pounds (n = 47). Prices charged by private laboratories ranged from 49.00 pounds to 84.00 pounds (n = 8). There was a log linear correlation in the NHS laboratories between the reagent costs per assay and the number of assays performed per year, and most laboratories thought that their price per assay would be sensitive to increases or decreases in demand. Laboratories which had purchased their assay machines had lower reagent costs per assay but higher repair and maintenance costs. Overall, number of assays performed and method of payment for assay machinery only accounted for 44.8% of the observed variation in assay kit costs. CONCLUSIONS--The price range for gentamicin assays in the United Kingdom is wide and is only partially explained by the number of assays performed. Most laboratories believe that they would experience a reduction in unit cost as output increases. The currently offered range of prices is, in part, due to variation in the laboratories' approach to costing the service provided and some laboratories

  11. Strategies to optimize the biocompatibility of iron oxide nanoparticles - ;SPIONs safe by design;

    NASA Astrophysics Data System (ADS)

    Janko, Christina; Zaloga, Jan; Pöttler, Marina; Dürr, Stephan; Eberbeck, Dietmar; Tietze, Rainer; Lyer, Stefan; Alexiou, Christoph

    2017-06-01

    Various nanoparticle systems have been developed for medical applications in recent years. For constant improvement of efficacy and safety of nanoparticles, a close interdisciplinary interplay between synthesis, physicochemical characterizations and toxicological investigations is urgently needed. Based on combined toxicological data, we follow a ;safe-by design; strategy for our superparamagnetic iron oxide nanoparticles (SPION). Using complementary interference-free toxicological assay systems, we initially identified agglomeration tendencies in physiological fluids, strong uptake by cells and improvable biocompatibility of lauric acid (LA)-coated SPIONs (SPIONLA). Thus, we decided to further stabilize those particles by an artificial protein corona consisting of serum albumin. This approach finally lead to increased colloidal stability, augmented drug loading capacity and improved biocompatibility in previous in vitro assays. Here, we show in whole blood ex vivo and on isolated red blood cells (RBC) that a protein corona protects RBCs from hemolysis by SPIONs.

  12. Tailoring of the titanium surface by immobilization of heparin/fibronectin complexes for improving blood compatibility and endothelialization: an in vitro study.

    PubMed

    Li, Guicai; Yang, Ping; Liao, Yuzhen; Huang, Nan

    2011-04-11

    To improve the blood compatibility and endothelialization simultaneously and to ensure the long-term effectiveness of the cardiovascular implants, we developed a surface modification method, enabling the coimmobilization of biomolecules to metal surfaces. In the present study, a heparin and fibronectin mixture (Hep/Fn) covalently immobilized on a titanium (Ti) substrate for biocompatibility was investigated. Different systems [N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide and N-hydroxysuccinimide, electrostatic] were used for the formation of Hep/Fn layers. Atomic force microscopy (AFM) showed that the roughness of the silanized Ti surface decreased after the immobilization of Hep/Fn. Fourier transform infrared spectroscopy (FTIR), Toluidine Blue O (TBO) test, and immunochemistry assay showed that Hep/Fn mixture was successfully immobilized on Ti surface. Blood compatibility tests (hemolysis rate, APTT, platelet adhesion, fibrinogen conformational change) showed that the coimmobilized films of Hep/Fn mixture reduced blood hemolysis rate, prolonged blood coagulation time, reduced platelets activation and aggregation, and induced less fibrinogen conformational change compared with a bare Ti surface. Endothelial cell (EC) seeding showed more EC with better morphology on pH 4 samples than on pH 7 and EDC/NHS samples, which showed rounded and aggregated cells. Systematic evaluation showed that the pH 4 samples also had much better blood compatibility. All results suggest that the coimmobilized films of Hep/Fn can confer excellent antithrombotic properties and with good endothelialization. We envisage that this method will provide a potential and effective solution for the surface modification of cardiovascular implant materials.

  13. Preliminary assessment of free radical scavenging, thrombolytic and membrane stabilizing capabilities of organic fractions of Callistemon citrinus (Curtis.) skeels leaves.

    PubMed

    Ahmed, Farhana; Rahman, Mohammad Sharifur

    2016-07-26

    Callistemon citrinus (Curtis.) (Family- Myrtaceae) is a popular evergreen shrub in Bangladesh. In the present study, the leaves of this plant have been assessed comprehensively for free radical scavenging, thrombolytic and membrane stabilizing activities. The leaves were collected, powdered and extracted with methanol. The extract was then concentrated and successively fractionated into petroleum ether, carbon tetrachloride, chloroform and aqueous soluble fractions. The extractives were investigated for free radical scavenging, thrombolytic and membrane stabilizing activities. In case of 1,1 diphenyl-2-picrylhydrazyl (DPPH) and hydrogen peroxide radical scavenging assays, the crude methanol extract of the leaves showed the highest free radical scavenging activity among the tested materials including standard ascorbic acid (p = 0.0000). Besides, this extract was also found significantly rich (p = 0.0000) in phenolics and flavonoids compared to other organic fractions. In thrombolytic study, the petroleum ether fraction exhibited significantly stronger thrombolysis (p = 0.024) than other leaf extractives but was weaker than the standard streptokinase. In membrane stabilizing assay, the activity of chloroform fraction was similar to that of standard acetylsalicylic acid (p = 1.000) in hypotonic solution induced hemolysis. However, membrane stabilization activity of this chloroform fraction was found significantly stronger than that of the standard (p = 0.0000) in heat induced hemolysis. This study has revealed the medicinal capabilities of different organic fractions of C. citrinus displaying free radical scavenging, thrombolysis and membrane stabilizing antiinflammatory potentials. Further bioactivity guided isolation is required to obtain pharmacologically secondary metabolites.

  14. Biocompatibility and in vivo degradation of chitosan based hydrogels as potential drug carrier.

    PubMed

    Su, Feng; Wang, Yuandou; Liu, Xue; Shen, Xin; Zhang, Xingjian; Xing, Quansheng; Wang, Lihong; Chen, Yangsheng

    2018-06-07

    Carboxymethyl chitosan-graft-polylactide (CMCS-PLA) and carboxymethyl chitosan (CMCS) hydrogels were prepared by using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride/N-hydroxysuccinimide (EDC/NHS) as crosslinking agent and catalyst at room temperature. The biocompatibility of the hydrogels was evaluated with the aim of assessing their potential as drug carrier. Various aspects of biocompatibility were considered, including MTT assay, agar diffusion test, release of lactate dehydrogenase (LDH), hemolytic test, plasma recalcification time (PRT), and dynamic clotting time. MTT assay showed that the cytotoxicity level of both hydrogels to L-929 cells was 0 or 1. The LDH release of CMCS and CMCS-PLA was 26 and 29%, respectively, which is slightly higher than that of the negative control (21%) and much lower than that of the negative control (87%). The hemolysis ratio of CMCS and CMCS-PLA was 1.4 and 1.7%, respectively, suggesting outstanding anti-hemolysis properties of both materials. The PRT value of CMCS and CMCS-PLA was higher by 77 and 99% than the value of the positive control. All the results revealed that the hydrogels present good cytocompatibility and hemocompatibility in vitro. In vivo degradation and tissue compatibility were evaluated by subcutaneous injection in the dorsal area of rats. CMCS and CMCS-PLA hydrogels were completely degraded and the inflammatory response also completely disappeared around hydrogels after 19 days in vivo. It is thus concluded that hydrogels formed of CMCS and CMCS-PLA with outstanding biocompatibility are promising as potential drug carrier.

  15. A simple and rapid microplate assay for glycoprotein-processing glycosidases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, M.S.; Zwolshen, J.H.; Harry, B.S.

    1989-08-15

    A simple and convenient microplate assay for glycosidases involved in the glycoprotein-processing reactions is described. The assay is based on specific binding of high-mannose-type oligosaccharide substrates to concanavalin A-Sepharose, while monosaccharides liberated by enzymatic hydrolysis do not bind to concanavalin A-Sepharose. By the use of radiolabeled substrates (( 3H)glucose for glucosidases and (3H)mannose for mannosidases), the radioactivity in the liberated monosaccharides can be determined as a measure of the enzymatic activity. This principle was employed earlier for developing assays for glycosidases previously reported. These authors have reported the separation of substrate from the product by concanavalin A-Sepharose column chromatography. Thismore » procedure is handicapped by the fact that it cannot be used for a large number of samples and is time consuming. We have simplified this procedure and adapted it to the use of a microplate (96-well plate). This would help in processing a large number of samples in a short time. In this report we show that the assay is comparable to the column assay previously reported. It is linear with time and enzyme concentration and shows expected kinetics with castanospermine, a known inhibitor of alpha-glucosidase I.« less

  16. Clinical Validation of Multiplex Real-Time PCR Assays for Detection of Bacterial Meningitis Pathogens

    PubMed Central

    Theodore, M. Jordan; Mair, Raydel; Trujillo-Lopez, Elizabeth; du Plessis, Mignon; Wolter, Nicole; Baughman, Andrew L.; Hatcher, Cynthia; Vuong, Jeni; Lott, Lisa; von Gottberg, Anne; Sacchi, Claudio; McDonald, J. Matthew; Messonnier, Nancy E.; Mayer, Leonard W.

    2012-01-01

    Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae are important causes of meningitis and other infections, and rapid, sensitive, and specific laboratory assays are critical for effective public health interventions. Singleplex real-time PCR assays have been developed to detect N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA and serogroup-specific genes in the cap locus for N. meningitidis serogroups A, B, C, W135, X, and Y. However, the assay sensitivity for serogroups B, W135, and Y is low. We aimed to improve assay sensitivity and develop multiplex assays to reduce time and cost. New singleplex real-time PCR assays for serogroup B synD, W135 synG, and Y synF showed 100% specificity for detecting N. meningitidis species, with high sensitivity (serogroup B synD, 99% [75/76]; W135 synG, 97% [38/39]; and Y synF, 100% [66/66]). The lower limits of detection (LLD) were 9, 43, and 10 copies/reaction for serogroup B synD, W135 synG, and Y synF assays, respectively, a significant improvement compared to results for the previous singleplex assays. We developed three multiplex real-time PCR assays for detection of (i) N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA (NHS assay); (ii) N. meningitidis serogroups A, W135, and X (AWX assay); and (iii) N. meningitidis serogroups B, C, and Y (BCY assay). Each multiplex assay was 100% specific for detecting its target organisms or serogroups, and the LLD was similar to that for the singleplex assay. Pairwise comparison of real-time PCR between multiplex and singleplex assays showed that cycle threshold values of the multiplex assay were similar to those for the singleplex assay. There were no substantial differences in sensitivity and specificity between these multiplex and singleplex real-time PCR assays. PMID:22170919

  17. Clinical validation of multiplex real-time PCR assays for detection of bacterial meningitis pathogens.

    PubMed

    Wang, Xin; Theodore, M Jordan; Mair, Raydel; Trujillo-Lopez, Elizabeth; du Plessis, Mignon; Wolter, Nicole; Baughman, Andrew L; Hatcher, Cynthia; Vuong, Jeni; Lott, Lisa; von Gottberg, Anne; Sacchi, Claudio; McDonald, J Matthew; Messonnier, Nancy E; Mayer, Leonard W

    2012-03-01

    Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae are important causes of meningitis and other infections, and rapid, sensitive, and specific laboratory assays are critical for effective public health interventions. Singleplex real-time PCR assays have been developed to detect N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA and serogroup-specific genes in the cap locus for N. meningitidis serogroups A, B, C, W135, X, and Y. However, the assay sensitivity for serogroups B, W135, and Y is low. We aimed to improve assay sensitivity and develop multiplex assays to reduce time and cost. New singleplex real-time PCR assays for serogroup B synD, W135 synG, and Y synF showed 100% specificity for detecting N. meningitidis species, with high sensitivity (serogroup B synD, 99% [75/76]; W135 synG, 97% [38/39]; and Y synF, 100% [66/66]). The lower limits of detection (LLD) were 9, 43, and 10 copies/reaction for serogroup B synD, W135 synG, and Y synF assays, respectively, a significant improvement compared to results for the previous singleplex assays. We developed three multiplex real-time PCR assays for detection of (i) N. meningitidis ctrA, H. influenzae hpd, and S. pneumoniae lytA (NHS assay); (ii) N. meningitidis serogroups A, W135, and X (AWX assay); and (iii) N. meningitidis serogroups B, C, and Y (BCY assay). Each multiplex assay was 100% specific for detecting its target organisms or serogroups, and the LLD was similar to that for the singleplex assay. Pairwise comparison of real-time PCR between multiplex and singleplex assays showed that cycle threshold values of the multiplex assay were similar to those for the singleplex assay. There were no substantial differences in sensitivity and specificity between these multiplex and singleplex real-time PCR assays.

  18. Tube-Forming Assays.

    PubMed

    Brown, Ryan M; Meah, Christopher J; Heath, Victoria L; Styles, Iain B; Bicknell, Roy

    2016-01-01

    Angiogenesis involves the generation of new blood vessels from the existing vasculature and is dependent on many growth factors and signaling events. In vivo angiogenesis is dynamic and complex, meaning assays are commonly utilized to explore specific targets for research into this area. Tube-forming assays offer an excellent overview of the molecular processes in angiogenesis. The Matrigel tube forming assay is a simple-to-implement but powerful tool for identifying biomolecules involved in angiogenesis. A detailed experimental protocol on the implementation of the assay is described in conjunction with an in-depth review of methods that can be applied to the analysis of the tube formation. In addition, an ImageJ plug-in is presented which allows automatic quantification of tube images reducing analysis times while removing user bias and subjectivity.

  19. Detection of Streptococcus pyogenes using rapid visual molecular assay.

    PubMed

    Zhao, Xiangna; He, Xiaoming; Li, Huan; Zhao, Jiangtao; Huang, Simo; Liu, Wei; Wei, Xiao; Ding, Yiwei; Wang, Zhaoyan; Zou, Dayang; Wang, Xuesong; Dong, Derong; Yang, Zhan; Yan, Xiabei; Huang, Liuyu; Du, Shuangkui; Yuan, Jing

    2015-09-01

    Streptococcus pyogenes is an increasingly important pathogen in many parts of the world. Rapid and accurate detection of S. pyogenes aids in the control of the infection. In this study, a loop-mediated isothermal amplification (LAMP) assay was developed and validated for the specific detection of S. pyogenes. The assay incorporates two methods: a chromogenic analysis using a calcein/Mn(2+) complex and real-time turbidity monitoring to assess the reaction. Both methods detected the target DNA within 60 min under 64°C isothermal conditions. The assay used specifically designed primers to target spy1258, and correctly identified 111 strains of S. pyogenes and 32 non-S. pyogenes strains, including other species of the genus Streptococcus. Tests using reference strains showed that the LAMP assay was highly specific. The sensitivity of the assay, with a detection limit of 1.49 pg DNA, was 10-fold greater than that of PCR. The LAMP assay established in this study is simple, fast and sensitive, and does not rely upon any special equipment; thus, it could be employed in clinical diagnosis. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Three dimensional colorimetric assay assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charych, D.; Reichart, A.

    2000-06-27

    A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flu virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.

  1. Three dimensional colorimetric assay assemblies

    DOEpatents

    Charych, Deborah; Reichart, Anke

    2000-01-01

    A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flu virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.

  2. Three-dimensional colorimetric assay assemblies

    DOEpatents

    Charych, Deborah; Reichert, Anke

    2001-01-01

    A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flue virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.

  3. Improving anticancer efficacy of (–)-epigallocatechin-3-gallate gold nanoparticles in murine B16F10 melanoma cells

    PubMed Central

    Chen, Cheng-Cheung; Hsieh, Dar-Shih; Huang, Kao-Jean; Chan, Yi-Lin; Hong, Po-Da; Yeh, Ming-Kung; Wu, Chang-Jer

    2014-01-01

    (–)-Epigallocatechin-3-gallate (EGCG), the major bioactive constituent in green tea, has been reported to effectively inhibit the formation and development of tumors. To maximize the effectiveness of EGCG, we attached it to nanogold particles (EGCG-pNG) in various ratios to examine in vitro cytotoxicity and in vivo anti-cancer activity. EGCG-pNG showed improved anti-cancer efficacy in B16F10 murine melanoma cells; the cytotoxic effect in the melanoma cells treated with EGCG-pNG was 4.91 times higher than those treated with EGCG. The enhancement is achieved through mitochondrial pathway-mediated apoptosis as determined by annexin V assay, JC-10 staining, and caspase-3, -8, -9 activity assay. Moreover, EGCG-pNG was 1.66 times more potent than EGCG for inhibition of tumor growth in a murine melanoma model. In the hemolysis assay, the pNG surface conjugated with EGCG is most likely the key factor that contributes to the decreased release of hemoglobin from human red blood cells. PMID:24855338

  4. Hemolysis

    MedlinePlus

    ... eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: Elsevier Saunders; 2016:chap 161. Gallagher PG. Red blood ... Basic Principles and Practice . 6th ed. Philadelphia, PA: Elsevier; 2013:chap 43. Michel M. Autoimmune and intravascular ...

  5. Development of reproducible assays for polygalacturonase and pectinase.

    PubMed

    Li, Qian; Coffman, Anthony M; Ju, Lu-Kwang

    2015-05-01

    Polygalacturonase and pectinase activities reported in the literature were measured by several different procedures. These procedures do not give comparable results, partly owing to the complexity of the substrates involved. This work was aimed at developing consistent and efficient assays for polygalacturonase and pectinase activities, using polygalacturonic acid and citrus pectin, respectively, as the substrate. Different enzyme mixtures produced by Aspergillus niger and Trichoderma reesei with different inducing carbon sources were used for the method development. A series of experiments were conducted to evaluate the incubation time, substrate concentration, and enzyme dilution. Accordingly, for both assays the recommended (optimal) hydrolysis time is 30min and substrate concentration is 5g/L. For polygalacturonase, the sample should be adjusted to have 0.3-0.8U/mL polygalacturonase activity, because in this range the assay outcomes were consistent (independent of dilution factors). Such a range did not exist for the pectinase assay. The recommended procedure is to assay the sample at multiple (at least 2) dilution factors and determine, by linear interpolation, the dilution factor that would release reducing sugar equivalent to 0.4g/L d-galacturonic acid, and then calculate the activity of the sample accordingly (dilution factor×0.687U/mL). Validation experiments showed consistent results using these assays. Effects of substrate preparation methods were also examined. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Development of a novel assay for human tyrosyl DNA phosphodiesterase 2.

    PubMed

    Adhikari, Sanjay; Karmahapatra, Soumendra K; Elias, Hadi; Dhopeshwarkar, Priyanka; Williams, R Scott; Byers, Stephen; Uren, Aykut; Roy, Rabindra

    2011-09-01

    Tyrosyl DNA phosphodiesterase 2 (TDP2), a newly discovered enzyme that cleaves 5'-phosphotyrosyl bonds, is a potential target for chemotherapy. TDP2 possesses both 3'- and 5'-tyrosyl-DNA phosphodiesterase activity, which is generally measured in a gel-based assay using 3'- and 5'-phosphotyrosyl linkage at the 3' and 5' ends of an oligonucleotide. To understand the enzymatic mechanism of this novel enzyme, the gel-based assay is useful, but this technique is cumbersome for TDP2 inhibitor screening. For this reason, we have designed a novel assay using p-nitrophenyl-thymidine-5'-phosphate (T5PNP) as a substrate. This assay can be used in continuous colorimetric assays in a 96-well format. We compared the salt and pH effect on product formation with the colorimetric and gel-based assays and showed that they behave similarly. Steady-state kinetic studies showed that the 5' activity of TDP2 is 1000-fold more efficient than T5PNP. Tyrosyl DNA phosphodiesterase 1 (TDP1) and human AP-endonuclease 1 (APE1) could not hydrolyze T5PNP. Sodium orthovanadate, a known inhibitor of TDP2, inhibits product formation from T5PNP by TDP2 (IC(50)=40 mM). Our results suggest that this novel assay system with this new TDP2 substrate can be used for inhibitor screening in a high-throughput manner. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Hemolysis area: A new parameter of erythrocyte osmotic fragility for screening of thalassemia trait

    PubMed Central

    Tatu, Thanusak; Sweatman, Denis

    2018-01-01

    BACKGROUND: One-tube osmotic fragility test (OFT) is widely used for screening thalassemia traits. Interobserver variation may occur with 0.36% NaCl-based OFT due to the naked eye result reading style. PURPOSE: The purpose of this study was to establish and evaluate the novel numerical OFT-based parameter, so-called hemolysis area (HA), in screening thalassemia traits. MATERIALS AND METHODS: The portable spectrophotometer was invented capable of calculating the HA values. The HA values were then compared among 69, 156, and 19 blood samples having positive, negative, and suspicious 0.36% NaCl-based OFT results, respectively; 109 and 135 blood samples having mean corpuscular volume (MCV) ≤80 fL and >80 fL, respectively; and 138 and 106 blood samples having mean corpuscular hemoglobin (MCH) ≤27 pg and >27 pg, respectively. In addition, the HA values were compared in 166 blood samples having different globin gene genotypes. Finally, the HA cutoff value was determined by receiver operation curve (ROC) analysis. RESULTS: The HA values in samples having positive, suspicious, and negative 0.36% NaCl-based OFT were 33.3 ± 14.4, 42.9 ± 10.5, and 65.3 ± 13.4, respectively; in sample having MCV ≤80 fL and >80 fL were 43.1 ± 19.6 and 63.8 ± 14.5, respectively; and in samples having MCH ≤27 pg and >27 pg were 46.7 ± 20.1 and 64.8 ± 14.2, respectively. The HA values in normal, hemoglobin E, SEA-α thalassemia 1, and β-thalassemia traits were 67.1 ± 12.6, 36.4 ± 13.9, 20.2 ± 4.8, and 18.6 ± 1.1, respectively. All were significantly different. ROC analysis established 52.4 as the HA cutoff that had comparable effectiveness to the conventional screening tests. CONCLUSION: The new HA value was effective and could be an alternative choice for screening thalassemia traits. PMID:29692590

  8. Alarin but not its alternative-splicing form, GALP (Galanin-like peptide) has antimicrobial activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wada, Akihiro, E-mail: a-wada@nagasaki-u.ac.jp; Wong, Pooi-Fong; Hojo, Hironobu

    Highlights: • Alarin inhibits the growth of E. coli but not S. aureus. • Alarin’s potency is comparable to LL-37 in inhibiting the growth of E. coli. • Alarin can cause bacterial membrane blebbing. • Alalin does not induce hemolysis on erythrocytes. -- Abstract: Alarin is an alternative-splicing form of GALP (galanin-like peptide). It shares only 5 conserved amino acids at the N-terminal region with GALP which is involved in a diverse range of normal brain functions. This study seeks to investigate whether alarin has additional functions due to its differences from GALP. Here, we have shown using a radialmore » diffusion assay that alarin but not GALP inhibited the growth of Escherichia coli (strain ML-35). The conserved N-terminal region, however, remained essential for the antimicrobial activity of alarin as truncated peptides showed reduced killing effect. Moreover, alarin inhibited the growth of E. coli in a similar potency as human cathelicidin LL-37, a well-studied antimicrobial peptide. Electron microscopy further showed that alarin induced bacterial membrane blebbing but unlike LL-37, it did not cause hemolysis of erythrocytes. In addition, alarin is only active against the gram-negative bacteria, E. coli but not the gram-positive bacteria, Staphylococcus aureus. Thus, these data suggest that alarin has potentials as an antimicrobial and should be considered for the development in human therapeutics.« less

  9. Micropatterned comet assay enables high throughput and sensitive DNA damage quantification

    PubMed Central

    Ge, Jing; Chow, Danielle N.; Fessler, Jessica L.; Weingeist, David M.; Wood, David K.; Engelward, Bevin P.

    2015-01-01

    The single cell gel electrophoresis assay, also known as the comet assay, is a versatile method for measuring many classes of DNA damage, including base damage, abasic sites, single strand breaks and double strand breaks. However, limited throughput and difficulties with reproducibility have limited its utility, particularly for clinical and epidemiological studies. To address these limitations, we created a microarray comet assay. The use of a micrometer scale array of cells increases the number of analysable comets per square centimetre and enables automated imaging and analysis. In addition, the platform is compatible with standard 24- and 96-well plate formats. Here, we have assessed the consistency and sensitivity of the microarray comet assay. We showed that the linear detection range for H2O2-induced DNA damage in human lymphoblastoid cells is between 30 and 100 μM, and that within this range, inter-sample coefficient of variance was between 5 and 10%. Importantly, only 20 comets were required to detect a statistically significant induction of DNA damage for doses within the linear range. We also evaluated sample-to-sample and experiment-to-experiment variation and found that for both conditions, the coefficient of variation was lower than what has been reported for the traditional comet assay. Finally, we also show that the assay can be performed using a 4× objective (rather than the standard 10× objective for the traditional assay). This adjustment combined with the microarray format makes it possible to capture more than 50 analysable comets in a single image, which can then be automatically analysed using in-house software. Overall, throughput is increased more than 100-fold compared to the traditional assay. Together, the results presented here demonstrate key advances in comet assay technology that improve the throughput, sensitivity, and robustness, thus enabling larger scale clinical and epidemiological studies. PMID:25527723

  10. SNAP Assay Technology.

    PubMed

    O'Connor, Thomas P

    2015-12-01

    The most widely used immunoassay configuration is the enzyme-linked immunosorbent assay (ELISA) because the procedure produces highly sensitive and specific results and generally is easy to use. By definition, ELISAs are immunoassays used to detect a substance (typically an antigen or antibody) in which an enzyme is attached (conjugated) to one of the reactants and an enzymatic reaction is used to amplify the signal if the substance is present. Optimized ELISAs include several steps that are performed in sequence using a defined protocol that typically includes application of sample and an enzyme-conjugated antibody or antigen to an immobilized reagent, followed by wash and enzyme reaction steps. The SNAP assay is an in-clinic device that performs each of the ELISA steps in a timed sequential fashion with little consumer interface. The components and mechanical mechanism of the assay device are described. Detailed descriptions of features of the assay, which minimize nonspecific binding and enhance the ability to read results from weak-positive samples, are given. Basic principles used in assays with fundamentally different reaction mechanisms, namely, antigen-detection, antibody-detection, and competitive assays are given. Applications of ELISA technology, which led to the development of several multianalyte SNAP tests capable of testing for up to 6 analytes using a single-sample and a single-SNAP device are described. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  11. New Application of the Comet Assay

    PubMed Central

    Cortés-Gutiérrez, Elva I.; Dávila-Rodríguez, Martha I.; Fernández, José Luís; López-Fernández, Carmen; Gosálbez, Altea; Gosálvez, Jaime

    2011-01-01

    The comet assay is a well-established, simple, versatile, visual, rapid, and sensitive tool used extensively to assess DNA damage and DNA repair quantitatively and qualitatively in single cells. The comet assay is most frequently used to analyze white blood cells or lymphocytes in human biomonitoring studies, although other cell types have been examined, including buccal, nasal, epithelial, and placental cells and even spermatozoa. This study was conducted to design a protocol that can be used to generate comets in subnuclear units, such as chromosomes. The new technique is based on the chromosome isolation protocols currently used for whole chromosome mounting in electron microscopy, coupled to the alkaline variant of the comet assay, to detect DNA damage. The results show that migrant DNA fragments can be visualized in whole nuclei and isolated chromosomes and that they exhibit patterns of DNA migration that depend on the level of DNA damage produced. This protocol has great potential for the highly reproducible study of DNA damage and repair in specific chromosomal domains. PMID:21540337

  12. Antimicrobial, antibiofilm and cytotoxic activities of Hakea sericea Schrader extracts

    PubMed Central

    Luís, Ângelo; Breitenfeld, Luiza; Ferreira, Susana; Duarte, Ana Paula; Domingues, Fernanda

    2014-01-01

    Background: Hakea sericea Schrader is an invasive shrub in Portuguese forests. Objective: The goal of this work was to evaluate the antimicrobial activity of H. sericea extracts against several strains of microorganisms, including the ability to inhibit the formation of biofilms. Additionally the cytotoxic properties of these extracts, against human cells, were assessed. Materials and Methods: The antimicrobial activity of the methanolic extracts of H. sericea was assessed by disk diffusion assay and Minimum Inhibitory Concentration (MIC) value determination. The antibiofilm activity was determined by quantification of total biofilm biomass with crystal violet. Cytotoxicity was evaluated by hemolysis assay and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) test. Results: For Gram-positive bacteria, MIC values of H. sericea methanolic extracts ranged between 0.040 and 0.625 mg/mL, whereas the fruits extract yielded the lowest MIC for several strains of microorganisms, namely, S. aureus, B. cereus, L. monocytogenes and clinical methicillin-resistant S. aureus (MRSA). Stems and fruits extract at 2.5 mg/mL effectively eradicated the biofilm of S. aureus ATCC 25923, SA 01/10 and MRSA 12/10. Regarding leaves extract, hemolysis was not observed, and in the case of stems and fruits, hemolysis was verified only for higher concentrations, suggesting its low toxicity. Fruits extract presented no toxic effect to normal human dermal fibroblasts (NHDF) cells however for concentrations of 0.017 and 0.008 mg/mL this extract was able to decrease human breast adenocarcinoma cells (MCF-7) viability in about 60%, as MTT test results had confirmed. This is a clearly demonstrator of the cytotoxicity of this extract against MCF-7 cells. PMID:24914310

  13. RAS - Screens & Assays

    Cancer.gov

    A primary goal of the RAS Initiative is to develop assays for RAS activity, localization, and signaling and adapt those assays so they can be used for finding new drug candidates. Explore the work leading to highly validated screening protocols.

  14. Dendrimer-stabilized bismuth sulfide nanoparticles: synthesis, characterization, and potential computed tomography imaging applications.

    PubMed

    Fang, Yi; Peng, Chen; Guo, Rui; Zheng, Linfeng; Qin, Jinbao; Zhou, Benqing; Shen, Mingwu; Lu, Xinwu; Zhang, Guixiang; Shi, Xiangyang

    2013-06-07

    We report here a general approach to synthesizing dendrimer-stabilized bismuth sulfide nanoparticles (Bi2S3 DSNPs) for potential computed tomography (CT) imaging applications. In this study, ethylenediamine core glycidol hydroxyl-terminated generation 4 poly(amidoamine) dendrimers (G4.NGlyOH) were used as stabilizers to first complex the Bi(III) ions, followed by reaction with hydrogen sulfide to generate Bi2S3 DSNPs. By varying the molar ratio of Bi atom to dendrimer, stable Bi2S3 DSNPs with an average size range of 5.2-5.7 nm were formed. The formed Bi2S3 DSNPs were characterized via different techniques. X-ray absorption coefficient measurements show that the attenuation of Bi2S3 DSNPs is much higher than that of iodine-based CT contrast agent at the same molar concentration of the active element (Bi versus iodine). 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) cell viability assay and hemolysis assay reveal that the formed Bi2S3 DSNPs are noncytotoxic and have a negligible hemolysis effect in the studied concentration range. Furthermore, we show that cells incubated with the Bi2S3 DSNPs are able to be imaged using CT, a prominent enhancement at the point of rabbit injected subcutaneously with the Bi2S3 DSNPs is able to be visualized via CT scanning, and the mouse's pulmonary vein can be visualized via CT after intravenous injection of the Bi2S3 DSNPs. With the good biocompatibility, enhanced X-ray attenuation property, and tunable dendrimer chemistry, the designed Bi2S3 DSNPs should be able to be further functionalized, allowing them to be used as a highly efficient contrast agent for CT imaging of different biological systems.

  15. The [Mo₆Cl14]2- Cluster is Biologically Secure and Has Anti-Rotavirus Activity In Vitro.

    PubMed

    Rojas-Mancilla, Edgardo; Oyarce, Alexis; Verdugo, Viviana; Morales-Verdejo, Cesar; Echeverria, Cesar; Velásquez, Felipe; Chnaiderman, Jonas; Valiente-Echeverría, Fernando; Ramirez-Tagle, Rodrigo

    2017-07-05

    The molybdenum cluster [Mo₆Cl 14 ] 2- is a fluorescent component with potential for use in cell labelling and pharmacology. Biological safety and antiviral properties of the cluster are as yet unknown. Here, we show the effect of acute exposition of human cells and red blood cells to the molybdenum cluster and its interaction with proteins and antiviral activity in vitro. We measured cell viability of HepG2 and EA.hy926 cell lines exposed to increasing concentrations of the cluster (0.1 to 250 µM), by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) colorimetric assay. Hemolysis and morphological alterations of red blood cells, obtained from healthy donors, exposed to the cluster (10 to 200 µM) at 37 °C were analyzed. Furthermore, quenching of tryptophan residues of albumin was performed. Finally, plaque formation by rotavirus SA11 in MA104 cells treated with the cluster (100 to 300 µM) were analyzed. We found that all doses of the cluster showed similar cell viability, hemolysis, and morphology values, compared to control. Quenching of tryptophan residues of albumin suggests a protein-cluster complex formation. Finally, the cluster showed antiviral activity at 300 µM. These results indicate that the cluster [Mo₆Cl 14 ] 2- could be intravenously administered in animals at therapeutic doses for further in vivo studies and might be studied as an antiviral agent.

  16. Identification of six Listeria species by real-time PCR assay.

    PubMed

    Hage, E; Mpamugo, O; Ohai, C; Sapkota, S; Swift, C; Wooldridge, D; Amar, C F L

    2014-06-01

    The Listeria genus comprises 10 recognized species. Listeria monocytogenes causes listeriosis in humans and other animals primarily via contaminated food or animal feed. Listeria ivanovii causes listeriosis in animals and on rare occasions in humans. The identification of nonpathogenic species of Listeria in foods indicates that conditions exist that support the growth of pathogenic strains and is used to facilitate the implementation of control and prevention measures. This study shows the development and evaluation of a 5'exonuclease real-time PCR assay for the rapid identification of Listeria seeligeri, Listeria welshimeri, L. monocytogenes, L. ivanovii, Listeria grayi and Listeria innocua. The assay consists of two triplexes that were evaluated using 53 cultures of Gram-positive bacteria, including 49 Listeria spp. from human, animal, food or food-processing environments. The assay was rapid, specific and reproducible and could identify each of the six species from a mixture of strains. The developed assay proved to be a powerful means of rapidly identifying Listeria species and could be usefully implemented in busy specialist reference laboratories. The identification of species of Listeria from foods is important to monitor pathogenic strains and facilitates the implementation of control measures. This study shows the development and evaluation of a 5'exonuclease real-time PCR assay for the rapid identification of L. seeligeri, L. welshimeri, L. monocytogenes and L. ivanovii, L. grayi, L. innocua. The developed assay proved to be specific, rapid and reproducible and therefore could be implemented in busy specialist reference laboratories. © 2014 The Society for Applied Microbiology.

  17. The analytical validation of the Oncotype DX Recurrence Score assay

    PubMed Central

    Baehner, Frederick L

    2016-01-01

    In vitro diagnostic multivariate index assays are highly complex molecular assays that can provide clinically actionable information regarding the underlying tumour biology and facilitate personalised treatment. These assays are only useful in clinical practice if all of the following are established: analytical validation (i.e., how accurately/reliably the assay measures the molecular characteristics), clinical validation (i.e., how consistently/accurately the test detects/predicts the outcomes of interest), and clinical utility (i.e., how likely the test is to significantly improve patient outcomes). In considering the use of these assays, clinicians often focus primarily on the clinical validity/utility; however, the analytical validity of an assay (e.g., its accuracy, reproducibility, and standardisation) should also be evaluated and carefully considered. This review focuses on the rigorous analytical validation and performance of the Oncotype DX® Breast Cancer Assay, which is performed at the Central Clinical Reference Laboratory of Genomic Health, Inc. The assay process includes tumour tissue enrichment (if needed), RNA extraction, gene expression quantitation (using a gene panel consisting of 16 cancer genes plus 5 reference genes and quantitative real-time RT-PCR), and an automated computer algorithm to produce a Recurrence Score® result (scale: 0–100). This review presents evidence showing that the Recurrence Score result reported for each patient falls within a tight clinically relevant confidence interval. Specifically, the review discusses how the development of the assay was designed to optimise assay performance, presents data supporting its analytical validity, and describes the quality control and assurance programmes that ensure optimal test performance over time. PMID:27729940

  18. The analytical validation of the Oncotype DX Recurrence Score assay.

    PubMed

    Baehner, Frederick L

    2016-01-01

    In vitro diagnostic multivariate index assays are highly complex molecular assays that can provide clinically actionable information regarding the underlying tumour biology and facilitate personalised treatment. These assays are only useful in clinical practice if all of the following are established: analytical validation (i.e., how accurately/reliably the assay measures the molecular characteristics), clinical validation (i.e., how consistently/accurately the test detects/predicts the outcomes of interest), and clinical utility (i.e., how likely the test is to significantly improve patient outcomes). In considering the use of these assays, clinicians often focus primarily on the clinical validity/utility; however, the analytical validity of an assay (e.g., its accuracy, reproducibility, and standardisation) should also be evaluated and carefully considered. This review focuses on the rigorous analytical validation and performance of the Oncotype DX ® Breast Cancer Assay, which is performed at the Central Clinical Reference Laboratory of Genomic Health, Inc. The assay process includes tumour tissue enrichment (if needed), RNA extraction, gene expression quantitation (using a gene panel consisting of 16 cancer genes plus 5 reference genes and quantitative real-time RT-PCR), and an automated computer algorithm to produce a Recurrence Score ® result (scale: 0-100). This review presents evidence showing that the Recurrence Score result reported for each patient falls within a tight clinically relevant confidence interval. Specifically, the review discusses how the development of the assay was designed to optimise assay performance, presents data supporting its analytical validity, and describes the quality control and assurance programmes that ensure optimal test performance over time.

  19. Interference of magnesium corrosion with tetrazolium-based cytotoxicity assays.

    PubMed

    Fischer, Janine; Prosenc, Marc H; Wolff, Martin; Hort, Norbert; Willumeit, Regine; Feyerabend, Frank

    2010-05-01

    Magnesium (Mg) alloys are promising materials for the development of biodegradable implants. However, the current in vitro test procedures for cytotoxicity, cell viability and proliferation are not always suitable for this class of materials. In this paper we show that tetrazolium-salt-based assays, which are widely used in practice, are influenced by the corrosion products of Mg-based alloys. Corroded Mg converts tetrazolium salts to formazan, leading to a higher background and falsifying the results of cell viability. Tetrazolium-based assays are therefore not a useful tool for testing the cytotoxicity of Mg in static in vitro assays. Copyright (c) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  20. The Simplexa™ Group A Strep Direct Assay: a sample-to-answer molecular assay for the diagnosis of group A streptococcal pharyngitis.

    PubMed

    Tabb, Michelle M; Batterman, Hollis J

    2016-01-01

    The Simplexa™ Group A Strep Direct assay is intended for use on the Integrated Cycler for detection of Group A Streptococcus (GAS) directly from throat swabs that have not undergone nucleic acid extraction. A prospective study of 1352 samples in 4 geographically diverse sites showed an overall prevalence of GAS of 15.4%. The assay demonstrated 97.4% sensitivity and 95.2% specificity versus culture. The positive predictive value compared to culture was 72.7%. However, 46 out of 57 discrepant samples were Group A Strep positive when tested using a bi-directional sequencing method illustrating the increased sensitivity of the assay compared to culture for detection of GAS. Rapid and accurate diagnosis of GAS allows for timely treatment to decrease complications of this prevalent organism that continues to cause substantial morbidity and mortality worldwide.

  1. Analysis of Gold Ores by Fire Assay

    ERIC Educational Resources Information Center

    Blyth, Kristy M.; Phillips, David N.; van Bronswijk, Wilhelm

    2004-01-01

    Students of an Applied Chemistry degree course carried out a fire-assay exercise. The analysis showed that the technique was a worthwhile quantitative analytical technique and covered interesting theory including acid-base and redox chemistry and other concepts such as inquarting and cupelling.

  2. In vitro hemolysis and buffer capacity studies with the novel marine anticancer agent kahalalide F and its reconstitution vehicle cremophor EL/ethanol.

    PubMed

    Nuijen, B; Bouma, M; Manada, C; Jimeno, J M; Bult, A; Beijnen, J H

    2001-01-01

    An in vitro biocompatibility study was performed with the pharmaceutical formulation of the investigational, marine-derived anticancer agent kahalalide F developed for early clinical studies. The pharmaceutical formulation consists of a lyophilized product containing 150 micrograms kahalalide F, 3 mg citric acid, 3 mg polysorbate 80, and 150 mg of sucrose per dosage unit, to be reconstituted with 3 mL of a mixture composed of Cremophor EL, ethanol, and water (5/5/90% v/v/v), resulting in a solution of pH 3 and to be further diluted in normal saline for infusion. The reconstituted product, infusion solutions, and Cremophor/ethanol (CE) vehicle were tested for hemolytic potential and buffer capacity. No significant hemolysis due to the kahalalide F formulation as well as the CE vehicle was found using both a static and dynamic test model. FB-ratio's (ratio of formulation solution (F) and volume of blood simulant (B) necessary to maintain physiological pH) as a measure of the buffer capacity of the kahalalide F infusion solutions examined indicated that no vascular irritation due to pH effects is expected in the intended administration schedule in the forthcoming Phase I study.

  3. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen artus HBV RG kit.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-10-01

    Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. ApoHRP-based assay to measure intracellular regulatory heme.

    PubMed

    Atamna, Hani; Brahmbhatt, Marmik; Atamna, Wafa; Shanower, Gregory A; Dhahbi, Joseph M

    2015-02-01

    The majority of the heme-binding proteins possess a "heme-pocket" that stably binds to heme. Usually known as housekeeping heme-proteins, they participate in a variety of metabolic reactions (e.g., catalase). Heme also binds with lower affinity to the "Heme-Regulatory Motifs" (HRM) in specific regulatory proteins. This type of heme binding is known as exchangeable or regulatory heme (RH). Heme binding to HRM proteins regulates their function (e.g., Bach1). Although there are well-established methods for assaying total cellular heme (e.g., heme-proteins plus RH), currently there is no method available for measuring RH independent of the total heme (TH). The current study describes and validates a new method to measure intracellular RH. This method is based on the reconstitution of apo-horseradish peroxidase (apoHRP) with heme to form holoHRP. The resulting holoHRP activity is then measured with a colorimetric substrate. The results show that apoHRP specifically binds RH but not with heme from housekeeping heme-proteins. The RH assay detects intracellular RH. Furthermore, using conditions that create positive (hemin) or negative (N-methyl protoporphyrin IX) controls for heme in normal human fibroblasts (IMR90), the RH assay shows that RH is dynamic and independent of TH. We also demonstrated that short-term exposure to subcytotoxic concentrations of lead (Pb), mercury (Hg), or amyloid-β (Aβ) significantly alters intracellular RH with little effect on TH. In conclusion the RH assay is an effective assay to investigate intracellular RH concentration and demonstrates that RH represents ∼6% of total heme in IMR90 cells.

  5. Validation of an assay for quantification of alpha-amylase in saliva of sheep

    PubMed Central

    Fuentes-Rubio, Maria; Fuentes, Francisco; Otal, Julio; Quiles, Alberto; Hevia, María Luisa

    2016-01-01

    The objective of this study was to develop a time-resolved immunofluorometric assay (TR-IFMA) for quantification of salivary alpha-amylase in sheep. For that purpose, after the design of the assay, an analytical and a clinical validation were carried out. The analytical validation of the assay showed intra- and inter-assay coefficients of variation (CVs) of 6.1% and 10.57%, respectively and an analytical limit of detection of 0.09 ng/mL. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution. For clinical validation, a model of acute stress testing was conducted to determine whether expected significant changes in alpha-amylase were picked up in the newly developed assay. In that model, 11 sheep were immobilized and confronted with a sheepdog to induce stress. Saliva samples were obtained before stress induction and 15, 30, and 60 min afterwards. Salivary cortisol was measured as a reference of stress level. The results of TR-IFMA showed a significant increase (P < 0.01) in the concentration of alpha-amylase in saliva after stress induction. The assay developed in this study could be used to measure salivary alpha-amylase in the saliva of sheep and this enzyme could be a possible noninvasive biomarker of stress in sheep. PMID:27408332

  6. Micropatterned comet assay enables high throughput and sensitive DNA damage quantification.

    PubMed

    Ge, Jing; Chow, Danielle N; Fessler, Jessica L; Weingeist, David M; Wood, David K; Engelward, Bevin P

    2015-01-01

    The single cell gel electrophoresis assay, also known as the comet assay, is a versatile method for measuring many classes of DNA damage, including base damage, abasic sites, single strand breaks and double strand breaks. However, limited throughput and difficulties with reproducibility have limited its utility, particularly for clinical and epidemiological studies. To address these limitations, we created a microarray comet assay. The use of a micrometer scale array of cells increases the number of analysable comets per square centimetre and enables automated imaging and analysis. In addition, the platform is compatible with standard 24- and 96-well plate formats. Here, we have assessed the consistency and sensitivity of the microarray comet assay. We showed that the linear detection range for H2O2-induced DNA damage in human lymphoblastoid cells is between 30 and 100 μM, and that within this range, inter-sample coefficient of variance was between 5 and 10%. Importantly, only 20 comets were required to detect a statistically significant induction of DNA damage for doses within the linear range. We also evaluated sample-to-sample and experiment-to-experiment variation and found that for both conditions, the coefficient of variation was lower than what has been reported for the traditional comet assay. Finally, we also show that the assay can be performed using a 4× objective (rather than the standard 10× objective for the traditional assay). This adjustment combined with the microarray format makes it possible to capture more than 50 analysable comets in a single image, which can then be automatically analysed using in-house software. Overall, throughput is increased more than 100-fold compared to the traditional assay. Together, the results presented here demonstrate key advances in comet assay technology that improve the throughput, sensitivity, and robustness, thus enabling larger scale clinical and epidemiological studies. © The Author 2014. Published by

  7. Nutraceutical potential of hemp (Cannabis sativa L.) seeds and sprouts.

    PubMed

    Frassinetti, Stefania; Moccia, Eleonora; Caltavuturo, Leonardo; Gabriele, Morena; Longo, Vincenzo; Bellani, Lorenza; Giorgi, Gianluca; Giorgetti, Lucia

    2018-10-01

    In this study the antioxidant effect of Cannabis sativa L. seeds and sprouts (3 and 5 days of germination) was evaluated. Total polyphenols, flavonoids and flavonols content, when expressed on dry weight basis, were highest in sprouts; ORAC and DPPH (in vitro assays), CAA-RBC (cellular antioxidant activity in red blood cells) and hemolysis test (ex vivo assays) evidenced a good antioxidant activity higher in sprouts than in seeds. Untargeted analysis by high resolution mass spectrometry in negative ion mode allowed the identification of main polyphenols (caffeoyltyramine, cannabisin A, B, C) in seeds and of ω-6 (linoleic acid) in sprouts. Antimutagenic effect of seeds and sprouts extracts evidenced a significant decrease of mutagenesis induced by hydrogen peroxide in Saccharomyces cerevisiae D7 strain. In conclusion our results show that C. sativa seeds and sprouts exert beneficial effects on yeast and human cells and should be further investigated as a potential functional food. Copyright © 2018. Published by Elsevier Ltd.

  8. Evaluation of genotoxic effects of lead in pottery-glaze workers using micronucleus assay, alkaline comet assay and DNA diffusion assay.

    PubMed

    Kašuba, V; Rozgaj, R; Milić, M; Zelježić, D; Kopjar, N; Pizent, A; Kljaković-Gašpić, Z; Jazbec, A

    2012-10-01

    We investigated genotoxic effects of occupational exposure to lead acetate in pottery-glaze ceramic workers. The study was carried out in 30 exposed workers and 30 matched controls, to whom several biochemical parameters-the blood lead (B-Pb; range: exposed, 41.68-404.77; controls, 12-52) and cadmium (B-Cd) level, the activity of delta-aminolevulinic acid dehydratase (ALAD), erythrocyte protoporphyrin (EP), the level of vitamin B(12) and folate in serum-were measured. The genotoxic effects were evaluated by the alkaline comet assay, the DNA diffusion assay and micronucleus test in peripheral blood lymphocytes. Subjects exposed to lead had significantly higher B-Pb level and, consequently, increased values of tail intensity (TI), frequency of apoptotic and necrotic cells, and frequency of micronuclei (MN). In contrast, their activity of ALAD, the level of vitamin B(12) and folate in serum were significantly lower compared to controls. Poisson regression analysis showed a significant correlation of profession, duration of exposure, smoking, level of cadmium in blood, ALAD and EP with primary DNA damage. A majority of primary damage repairs in a short period after exposure to a genotoxic agent. In addition, the influence of gender and level of vitamin B(12) and folate in serum MN frequency in exposed group was observed. In this study, DNA diffusion and micronucleus test showed higher influence of tested parameters to DNA damage. The results indicate a need for concomitant use of at least two different biomarkers of exposure when estimating a genetic risk of lead exposure.

  9. Neutral Red versus MTT assay of cell viability in the presence of copper compounds.

    PubMed

    Gomez Perez, Mariela; Fourcade, Lyvia; Mateescu, Mircea Alexandru; Paquin, Joanne

    2017-10-15

    Copper is essential for numerous physiological functions, and copper compounds may display therapeutic as well as cytotoxic effects. The MTT (3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide) assay is a standard test largely used in cytotoxicity studies. This report shows that low micromolar levels of copper compounds such as Cu(II)Urea 2 , Cu(II)Ser 2 and CuCl 2 can interfere with the MTT assay making improper the detection of formazan product of MTT reduction. Comparatively, the Neutral Red assay appears to be sensitive and showing no interference with these compounds. The lactate dehydrogenase alternative assay cannot be used because of inhibitory effect of these copper compounds on the enzyme activity. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. An evaluation of the automated assay of urinary oestrogens in pregnant women

    PubMed Central

    Muir, G. G.; Ryan, M.; Conaill, D. U.

    1970-01-01

    An automated assay suitable for estimating urinary oestrogens in pregnant women has been investigated. Fluorimetry was found to have considerable advantages over colorimetry. The fluorimetric assay was simpler, more precise, more sensitive, and eliminated the need for correction for non-specific chromogens; in the assay of oestriol in pregnant women there was no need for correction for non-specific fluorescence. Spectrofluorimetric and photometric analyses, recoveries, and reproducibility show that the method offers a robust means of providing values for urinary oestrogen in pregnant women on a scale of up to 100 tests a day, the time of the assay being one and a half hours. PMID:5476876

  11. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  12. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  13. Evaluation of the reliability of maize reference assays for GMO quantification.

    PubMed

    Papazova, Nina; Zhang, David; Gruden, Kristina; Vojvoda, Jana; Yang, Litao; Buh Gasparic, Meti; Blejec, Andrej; Fouilloux, Stephane; De Loose, Marc; Taverniers, Isabel

    2010-03-01

    A reliable PCR reference assay for relative genetically modified organism (GMO) quantification must be specific for the target taxon and amplify uniformly along the commercialised varieties within the considered taxon. Different reference assays for maize (Zea mays L.) are used in official methods for GMO quantification. In this study, we evaluated the reliability of eight existing maize reference assays, four of which are used in combination with an event-specific polymerase chain reaction (PCR) assay validated and published by the Community Reference Laboratory (CRL). We analysed the nucleotide sequence variation in the target genomic regions in a broad range of transgenic and conventional varieties and lines: MON 810 varieties cultivated in Spain and conventional varieties from various geographical origins and breeding history. In addition, the reliability of the assays was evaluated based on their PCR amplification performance. A single base pair substitution, corresponding to a single nucleotide polymorphism (SNP) reported in an earlier study, was observed in the forward primer of one of the studied alcohol dehydrogenase 1 (Adh1) (70) assays in a large number of varieties. The SNP presence is consistent with a poor PCR performance observed for this assay along the tested varieties. The obtained data show that the Adh1 (70) assay used in the official CRL NK603 assay is unreliable. Based on our results from both the nucleotide stability study and the PCR performance test, we can conclude that the Adh1 (136) reference assay (T25 and Bt11 assays) as well as the tested high mobility group protein gene assay, which also form parts of CRL methods for quantification, are highly reliable. Despite the observed uniformity in the nucleotide sequence of the invertase gene assay, the PCR performance test reveals that this target sequence might occur in more than one copy. Finally, although currently not forming a part of official quantification methods, zein and SSIIb

  14. Mussel micronucleus cytome assay.

    PubMed

    Bolognesi, Claudia; Fenech, Michael

    2012-05-17

    The micronucleus (MN) assay is one of the most widely used genotoxicity biomarkers in aquatic organisms, providing an efficient measure of chromosomal DNA damage occurring as a result of either chromosome breakage or chromosome mis-segregation during mitosis. The MN assay is today applied in laboratory and field studies using hemocytes and gill cells from bivalves, mainly from the genera Mytilus. These represent 'sentinel' organisms because of their ability to survive under polluted conditions and to accumulate both organic and inorganic pollutants. Because the mussel MN assay also includes scoring of different cell types, including necrotic and apoptotic cells and other nuclear anomalies, it is in effect an MN cytome assay. The mussel MN cytome (MUMNcyt) assay protocol we describe here reports the recommended experimental design, sample size, cell preparation, cell fixation and staining methods. The protocol also includes criteria and photomicrographs for identifying different cell types and scoring criteria for micronuclei (MNi) and nuclear buds. The complete procedure requires approximately 10 h for each experimental point/sampling station (ten animals).

  15. TOTAL CULTURABLE VIRUS QUANTAL ASSAY

    EPA Science Inventory

    This chapter describes a quantal method for assaying culturable human enteric viruses from water matrices. The assay differs from the plaque assay described in Chapter 10 (December 1987 Revision) in that it is based upon the direct microscopic viewing of cells for virus-induced ...

  16. Detection of biotin in individual sea urchin oocytes using a bioluminescence binding assay.

    PubMed

    Feltus, A; Grosvenor, A L; Conover, R C; Anderson, K W; Daunert, S

    2001-04-01

    The ability to detect biomolecules in single cells is important in order to fully understand the processes by which many biochemical events occur. To that end, we have developed a bioluminescence binding assay capable of measuring the intracellular biotin content of individual cells. The assay depends on competition between an aequorin-biotin conjugate (AEQ-biotin) and free biotin within the oocytes for binding sites on the protein avidin. The assay is performed by microinjecting each component into the oocytes and following the resulting bioluminescence within the oocyte upon triggering of aequorin. Results obtained using sea urchin oocytes show that the assay performed within the cells behaves in a manner consistent with assay theory. Using the assay, the individual biotin content of the oocytes is an average of approximately 20 amol. To our knowledge, this is the first reported multicomponent binding assay to be performed inside an intact single cell.

  17. Bio-barcode gel assay for microRNA

    NASA Astrophysics Data System (ADS)

    Lee, Hyojin; Park, Jeong-Eun; Nam, Jwa-Min

    2014-02-01

    MicroRNA has been identified as a potential biomarker because expression level of microRNA is correlated with various cancers. Its detection at low concentrations would be highly beneficial for cancer diagnosis. Here, we develop a new type of a DNA-modified gold nanoparticle-based bio-barcode assay that uses a conventional gel electrophoresis platform and potassium cyanide chemistry and show this assay can detect microRNA at aM levels without enzymatic amplification. It is also shown that single-base-mismatched microRNA can be differentiated from perfectly matched microRNA and the multiplexed detection of various combinations of microRNA sequences is possible with this approach. Finally, differently expressed microRNA levels are selectively detected from cancer cells using the bio-barcode gel assay, and the results are compared with conventional polymerase chain reaction-based results. The method and results shown herein pave the way for practical use of a conventional gel electrophoresis for detecting biomolecules of interest even at aM level without polymerase chain reaction amplification.

  18. A rapid enzymatic assay for high-throughput screening of adenosine-producing strains

    PubMed Central

    Dong, Huina; Zu, Xin; Zheng, Ping; Zhang, Dawei

    2015-01-01

    Adenosine is a major local regulator of tissue function and industrially useful as precursor for the production of medicinal nucleoside substances. High-throughput screening of adenosine overproducers is important for industrial microorganism breeding. An enzymatic assay of adenosine was developed by combined adenosine deaminase (ADA) with indophenol method. The ADA catalyzes the cleavage of adenosine to inosine and NH3, the latter can be accurately determined by indophenol method. The assay system was optimized to deliver a good performance and could tolerate the addition of inorganic salts and many nutrition components to the assay mixtures. Adenosine could be accurately determined by this assay using 96-well microplates. Spike and recovery tests showed that this assay can accurately and reproducibly determine increases in adenosine in fermentation broth without any pretreatment to remove proteins and potentially interfering low-molecular-weight molecules. This assay was also applied to high-throughput screening for high adenosine-producing strains. The high selectivity and accuracy of the ADA assay provides rapid and high-throughput analysis of adenosine in large numbers of samples. PMID:25580842

  19. A novel fluorescent assay for sucrose transporters.

    PubMed

    Gora, Peter J; Reinders, Anke; Ward, John M

    2012-04-04

    We have developed a novel assay based on the ability of type I sucrose uptake transporters (SUTs) to transport the fluorescent coumarin β-glucoside, esculin. Budding yeast (Saccharomyces cerevisiae) is routinely used for the heterologous expression of SUTs and does not take up esculin. When type I sucrose transporters StSUT1 from potato or AtSUC2 from Arabidopsis were expressed in yeast, the cells were able to take up esculin and became brightly fluorescent. We tested a variety of incubation times, esculin concentrations, and buffer pH values and found that for these transporters, a 1 hr incubation at 0.1 to 1 mM esculin at pH 4.0 produced fluorescent cells that were easily distinguished from vector controls. Esculin uptake was assayed by several methods including fluorescence microscopy, spectrofluorometry and fluorescence-activiated cell sorting (FACS). Expression of the type II sucrose transporter OsSUT1 from rice did not result in increased esculin uptake under any conditions tested. Results were reproduced successfully in two distinct yeast strains, SEY6210 (an invertase mutant) and BY4742. The esculin uptake assay is rapid and sensitive and should be generally useful for preliminary tests of sucrose transporter function by heterologous expression in yeast. This assay is also suitable for selection of yeast showing esculin uptake activity using FACS.

  20. Identification and screening of potent antimicrobial peptides in arthropod genomes.

    PubMed

    Duwadi, Deepesh; Shrestha, Anishma; Yilma, Binyam; Kozlovski, Itamar; Sa-Eed, Munaya; Dahal, Nikesh; Jukosky, James

    2018-05-01

    Using tBLASTn and BLASTp searches, we queried recently sequenced arthropod genomes and expressed sequence tags (ESTs) using a database of known arthropod cecropins, defensins, and attacins. We identified and synthesized 6 potential AMPs and screened them for antimicrobial activity. Using radial diffusion assays and microtiter antimicrobial assays, we assessed the in vitro antimicrobial effects of these peptides against several human pathogens including Gram-positive and Gram-negative bacteria and fungi. We also conducted hemolysis assays to examine the cytotoxicity of these peptides to mammalian cells. Four of the six peptides identified showed antimicrobial effects in these assays. We also created truncated versions of these four peptides to assay their antimicrobial activity. Two cecropins derived from the monarch butterfly genome (Danaus plexippus), DAN1 and DAN2, showed minimum inhibitory concentrations (MICs) in the range of 2-16 μg/ml when screened against Gram-negative bacteria. HOLO1 and LOUDEF1, two defensin-like peptides derived from red flour beetle (Tribolium castaneum) and human body louse (Pediculus humanus humanus), respectively, exhibited MICs in the range of 13-25 μg/ml against Gram-positive bacteria. Furthermore, HOLO1 showed an MIC less than 5 μg/ml against the fungal species Candida albicans. These peptides exhibited no hemolytic activity at concentrations up to 200 μg/ml. The truncated peptides derived from DAN2 and HOLO1 showed very little antimicrobial activity. Our experiments show that the peptides DAN1, DAN2, HOLO1, and LOUDEF1 showed potent antimicrobial activity in vitro against common human pathogens, did not lyse mammalian red blood cells, and indicates their potential as templates for novel therapeutic agents against microbial infection. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries*

    PubMed Central

    Wu, Jemma X.; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P.

    2016-01-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. PMID:27161445

  2. Differential sensitivity of von Willebrand factor (VWF) 'activity' assays to large and small VWF molecular weight forms: a cross-laboratory study comparing ristocetin cofactor, collagen-binding and mAb-based assays.

    PubMed

    Favaloro, E J; Bonar, R; Chapman, K; Meiring, M; Funk Adcock, D

    2012-06-01

    von Willebrand disease (VWD), the most common inherited bleeding disorder, is caused by deficiencies and/or defects in von Willebrand factor (VWF). An effective diagnostic and VWD typing strategy requires plasma testing for factor VIII, and VWF antigen plus one or more VWF 'activity' assays. VWF activity is classically assessed by using VWF ristocetin cofactor activity (VWF:RCo), although VWF collagen-binding (VWF:CB) and VWF mAb-based (VWF activity [VWF:Act]) assays are used by some laboratories. To perform a cross-laboratory study to specifically evaluate these three VWF activity assays for comparative sensitivity to loss of high molecular weight (HMW) VWF, representing the form of VWF that is most functionally active and that is absent in some types of VWD, namely 2A and 2B. A set of eight samples, including six selectively representing stepwise reduction in HMW VWF, were tested by 51 different laboratories using a variety of assays. The combined data showed that the VWF:CB and VWF:RCo assays had higher sensitivity to the loss of HMW VWF than did the VWF:Act assay. Moreover, within-method analysis identified better HMW VWF sensitivity of some VWF:CB assays than of others, with all VWF:CB assays still showing better sensitivity than the VWF:Act assay. Differences were also identified between VWF:RCo methodologies on the basis of either platelet aggregometry or as performed on automated analyzers. We believe that these results have significant clinical implications for the diagnosis of VWD and monitoring of its therapy, as well as for the future diagnosis and therapy monitoring of thrombotic thrombocytopenic purpura. © 2012 International Society on Thrombosis and Haemostasis.

  3. International collaborative studies on potency assays of diphtheria and tetanus toxoids.

    PubMed

    Van Ramshorst, J D; Sundaresan, T K; Outschoorn, A S

    1972-01-01

    Collaborative studies showed that relative potency assays for a particular type of diphtheria toxoid (adsorbed) and for tetanus toxoid (plain and adsorbed) gave very similar results, whether the assays were carried out by toxin challenge or by antitoxin titration after immunization of experimental animals with graded doses of toxoid. The same numerical results were obtained with a scoring system as with a system based on survivals only. Although skin tests were used on a very limited scale in these studies, it seems likely that they could replace lethal tests for the diphtheria challenge assays.For both tetanus and diphtheria, the adsorbed toxoid gave a higher relative potency when combined with other antigens than as a single toxoid. Both mice and guinea-pigs were used for the lethal challenge test of adsorbed tetanus toxoid. For the single tetanus toxoid the results were the same, but for the combined toxoid (DPT vaccine) the mouse assay results were about twice those of guinea-pig assays.

  4. International collaborative studies on potency assays of diphtheria and tetanus toxoids

    PubMed Central

    van Ramshorst, J. D.; Sundaresan, T. K.; Outschoorn, A. S.

    1972-01-01

    Collaborative studies showed that relative potency assays for a particular type of diphtheria toxoid (adsorbed) and for tetanus toxoid (plain and adsorbed) gave very similar results, whether the assays were carried out by toxin challenge or by antitoxin titration after immunization of experimental animals with graded doses of toxoid. The same numerical results were obtained with a scoring system as with a system based on survivals only. Although skin tests were used on a very limited scale in these studies, it seems likely that they could replace lethal tests for the diphtheria challenge assays. For both tetanus and diphtheria, the adsorbed toxoid gave a higher relative potency when combined with other antigens than as a single toxoid. Both mice and guinea-pigs were used for the lethal challenge test of adsorbed tetanus toxoid. For the single tetanus toxoid the results were the same, but for the combined toxoid (DPT vaccine) the mouse assay results were about twice those of guinea-pig assays. PMID:4537488

  5. A perspective on the hemolytic activity of chemical and green-synthesized silver and silver oxide nanoparticles

    NASA Astrophysics Data System (ADS)

    Ashokraja, C.; Sakar, M.; Balakumar, S.

    2017-10-01

    We report the hemolysis properties of silver and silver oxide nanoparticles (NPs) prepared by chemical and green-synthesis methods. The prepared silver and silver oxide NPs were analyzed using UV-vis spectroscopy to confirm their formation by characterizing their surface plasmon resonance (SPR) and absorption band peaks respectively. The Fourier transmission infrared (FTIR) spectra of the materials showed the characteristic functional groups corresponding to the molecules present in leaf extracts, which is proposed to be acted as reducing and capping agents that are also found on the surface of silver and silver oxide nanoparticles that synthesized via green-synthesis method. Zeta potential analysis revealed the surface charge and stability of the prepared NPs. HRTEM images showed almost spherical shape nanoparticles with an average size of 15.2 and 31.5 nm for wet chemical synthesized silver and silver oxide nanoparticles respectively. In the case of green synthesized silver and silver oxide nanoparticles, it was observed to be 19.4 and 30.4 nm respectively. The order of hemolysis efficacy of the materials is found to be as follows: chemically synthesized Ag2O>  chemically synthesized Ag NPs followed by green-synthesized Ag2O and green-synthesized Ag NPs which showed almost similar hemolysis with respect to concentration. The relatively stable nature of the silver NPs could be attributed to their lower hemolysis efficacy, while the increased lysis properties of silver oxide could be attributed due to reductive/oxidative processes that give rise to the hemolysis through interfacial charge interactions with RBCs.

  6. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  7. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  8. Ultrastructural Interactions and Genotoxicity Assay of Cerium Dioxide Nanoparticles on Mouse Oocytes

    PubMed Central

    Courbiere, Blandine; Auffan, Mélanie; Rollais, Raphaël; Tassistro, Virginie; Bonnefoy, Aurélie; Botta, Alain; Rose, Jérôme; Orsière, Thierry; Perrin, Jeanne

    2013-01-01

    Cerium dioxide nanoparticles (CeO2 ENPs) are on the priority list of nanomaterials requiring evaluation. We performed in vitro assays on mature mouse oocytes incubated with CeO2 ENPs to study (1) physicochemical biotransformation of ENPs in culture medium; (2) ultrastructural interactions with follicular cells and oocytes using Transmission Electron Microscopy (TEM); (3) genotoxicity of CeO2 ENPs on follicular cells and oocytes using a comet assay. DNA damage was quantified as Olive Tail Moment. We show that ENPs aggregated, but their crystal structure remained stable in culture medium. TEM showed endocytosis of CeO2 ENP aggregates in follicular cells. In oocytes, CeO2 ENP aggregates were only observed around the zona pellucida (ZP). The comet assay revealed significant DNA damage in follicular cells. In oocytes, the comet assay showed a dose-related increase in DNA damage and a significant increase only at the highest concentrations. DNA damage decreased significantly both in follicular cells and in oocytes when an anti-oxidant agent was added in the culture medium. We hypothesise that at low concentrations of CeO2 ENPs oocytes could be protected against indirect oxidative stress due to a double defence system composed of follicular cells and ZP. PMID:24185910

  9. A novel reporter gene assay for recombinant human erythropoietin (rHuEPO) pharmaceutical products.

    PubMed

    Yang, Yushuai; Zhou, Yong; Yu, Lei; Li, Xiang; Shi, Xinchang; Qin, Xi; Rao, Chunming; Wang, Junzhi

    2014-11-01

    Accurate determination of in vitro biological activity of therapeutic erythropoietin is essential in quality control of recombinant human erythropoietin (rHuEPO) pharmaceutical products. However, most of currently-used methods leave much to be desired so that a simpler, quicker and more accurate method is urgently needed. The bioassay described here utilizes a sub clone of UT-7/epo cell line stably transfected with luciferase gene under the control of sis inducible element and interferon γ-activated sequence element promoter. Active erythropoietin could induce the expression of luciferase by signaling through the erythropoietin receptor and the dose-response curve showed good linearity, yielding a coefficient of determination of 0.99 or higher. The optimized assay was simpler with the operation completed within 24h and more sensitive with EC50 being 0.077IU/mL. The accuracy estimates ranged from 81.7% to 102.4%, and both intra-assay and inter-assay precision was below 15.0%. The robustness of the assay was demonstrated by no effect of passage levels of the cells on the performance of the assay (p values: 0.772 for sample 1 and 0.943 for sample 2). Besides, Bland-Altman analysis showed a high consistency of the new assay with in vivo reticulocyte assay in results. These results suggested that the new reporter gene assay can be a viable supplement to the traditional reticulocyte assay and employed in potency determination of rHuEPO pharmaceutical products. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Antioxidant and Hypolipidemic Activity of the Hydroethanolic Extract of Curatella americana L. Leaves.

    PubMed

    Lopes, Rafael Henrique Oliveira; Macorini, Luis Fernando Benitez; Antunes, Katia Ávila; Espindola, Priscilla Pereira de Toledo; Alfredo, Tamaeh Monteiro; da Rocha, Paola Dos Santos; Pereira, Zefa Valdivina; Dos Santos, Edson Lucas; de Picoli Souza, Kely

    2016-01-01

    High levels of reactive oxygen species in the body and hyperlipidemia are key factors for the development of cardiovascular diseases such as atherosclerosis. The present study investigated the antioxidant and hypolipidemic activity of hydroethanolic extract of Curatella americana L. leaves (ExC). The antioxidant activity of ExC was assessed by 2,2-diphenyl-1-picrylhydrazyl free radical (DPPH) scavenging capacity and protection against hemolysis induced by 2,2'-azobis(2-amidinopropane) dihydrochloride (AAPH), followed by quantification of malondialdehyde (MDA). Wistar rats with hyperlipidemia induced by high-fructose diet (60%) were treated for 60 days with water, simvastatin (30 mg·Kg(-1)), ciprofibrate (2 mg·Kg(-1)), and ExC (200 mg·Kg(-1)). ExC revealed IC50 of 6.0 ± 0.5 μg·mL(-1), an intermediary value among positive controls used in the assay of DPPH scavenging capacity. At all concentrations (50 to 125 μg·mL(-1)) and times (60 to 240 min) evaluated, ExC protected erythrocytes against AAPH-induced hemolysis, which was confirmed by lower MDA levels. In vivo tests showed a reduction of 34 and 45%, respectively, in serum concentration of cholesterol and triglycerides in hyperlipidemic rats treated with ExC, a similar effect compared to the reference drugs, simvastatin and ciprofibrate, respectively. Together, the results showed the antioxidant activity of ExC and its ability to improve the serum lipid profile in hyperlipidemic rats.

  11. Comprehensive analysis of sperm DNA fragmentation by five different assays: TUNEL assay, SCSA, SCD test and alkaline and neutral Comet assay.

    PubMed

    Ribas-Maynou, J; García-Peiró, A; Fernández-Encinas, A; Abad, C; Amengual, M J; Prada, E; Navarro, J; Benet, J

    2013-09-01

    Sperm DNA fragmentation (SDF) is becoming an important test to assess male infertility. Several different tests are available, but no consensus has yet been reached as to which tests are most predictive of infertility. Few publications have reported a comprehensive analysis comparing these methods within the same population. The objective of this study was to analyze the differences between the five most common methodologies, to study their correlations and to establish their cut-off values, sensitivity and specificity in predicting male infertility. We found differences in SDF between fertile donors and infertile patients in TUNEL, SCSA, SCD and alkaline Comet assays, but none with the neutral Comet assay. The alkaline COMET assay was the best in predicting male infertility followed by TUNEL, SCD and SCSA, whereas the neutral COMET assay had no predictive power. For our patient population, threshold values for infertility were 20.05% for TUNEL assay, 18.90% for SCSA, 22.75% for the SCD test, 45.37% for alkaline Comet and 34.37% for neutral Comet. This work establishes in a comprehensive study that the all techniques except neutral Comet are useful to distinguish fertile and infertile men. © 2013 American Society of Andrology and European Academy of Andrology.

  12. Erythrocytes and cell line-based assays to evaluate the cytoprotective activity of antioxidant components obtained from natural sources.

    PubMed

    Botta, Albert; Martínez, Verónica; Mitjans, Montserrat; Balboa, Elena; Conde, Enma; Vinardell, M Pilar

    2014-02-01

    Oxidative stress can damage cellular components including DNA, proteins or lipids, and may cause several skin diseases. To protect from this damage and addressing consumer's appeal to natural products, antioxidants obtained from algal and vegetal extracts are being proposed as antioxidants to be incorporated into formulations. Thus, the development of reliable, quick and economic in vitro methods to study the cytoactivity of these products is a meaningful requirement. A combination of erythrocyte and cell line-based assays was performed on two extracts from Sargassum muticum, one from Ulva lactuca, and one from Castanea sativa. Antioxidant properties were assessed in erythrocytes by the TBARS and AAPH assays, and cytotoxicity and antioxidant cytoprotection were assessed in HaCaT and 3T3 cells by the MTT assay. The extracts showed no antioxidant activity on the TBARS assay, whereas their antioxidant capacity in the AAPH assay was demonstrated. On the cytotoxicity assays, extracts showed low toxicity, with IC50 values higher than 200μg/mL. C. sativa extract showed the most favourable antioxidant properties on the antioxidant cytoprotection assays; while S. muticum and U. lactuca extracts showed a slight antioxidant activity. This battery of methods was useful to characterise the biological antioxidant properties of these natural extracts. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Microbiological assay for the determination of meropenem in pharmaceutical dosage form.

    PubMed

    Mendez, Andreas S L; Weisheimer, Vanessa; Oppe, Tércio P; Steppe, Martin; Schapoval, Elfrides E S

    2005-04-01

    Meropenem is a highly active carbapenem antibiotic used in the treatment of a wide range of serious infections. The present work reports a microbiological assay, applying the cylinder-plate method, for the determination of meropenem in powder for injection. The validation method yielded good results and included linearity, precision, accuracy and specificity. The assay is based on the inhibitory effect of meropenem upon the strain of Micrococcus luteus ATCC 9341 used as the test microorganism. The results of assay were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9999) in the range of 1.5-6.0 microg ml(-1), precise (intra-assay: R.S.D.=0.29; inter-assay: R.S.D.=0.94) and accurate. A preliminary stability study of meropenem was performed to show that the microbiological assay is specific for the determination of meropenem in the presence of its degradation products. The degraded samples were also analysed by the HPLC method. The proposed method allows the quantitation of meropenem in pharmaceutical dosage form and can be used for the drug analysis in routine quality control.

  14. Microplate-based filter paper assay to measure total cellulase activity.

    PubMed

    Xiao, Zhizhuang; Storms, Reginald; Tsang, Adrian

    2004-12-30

    The standard filter paper assay (FPA) published by the International Union of Pure and Applied Chemistry (IUPAC) is widely used to determine total cellulase activity. However, the IUPAC method is not suitable for the parallel analyses of large sample numbers. We describe here a microplate-based method for assaying large sample numbers. To achieve this, we reduced the enzymatic reaction volume to 60 microl from the 1.5 ml used in the IUPAC method. The modified 60-microl format FPA can be carried out in 96-well assay plates. Statistical analyses showed that the cellulase activities of commercial cellulases from Trichoderma reesei and Aspergillus species determined with our 60-microl format FPA were not significantly different from the activities measured with the standard FPA. Our results also indicate that the 60-microl format FPA is quantitative and highly reproducible. Moreover, the addition of excess beta-glucosidase increased the sensitivity of the assay by up to 60%. 2004 Wiley Periodicals, Inc.

  15. MTS dye based colorimetric CTLL-2 cell proliferation assay for product release and stability monitoring of interleukin-15: assay qualification, standardization and statistical analysis.

    PubMed

    Soman, Gopalan; Yang, Xiaoyi; Jiang, Hengguang; Giardina, Steve; Vyas, Vinay; Mitra, George; Yovandich, Jason; Creekmore, Stephen P; Waldmann, Thomas A; Quiñones, Octavio; Alvord, W Gregory

    2009-08-31

    A colorimetric cell proliferation assay using soluble tetrazolium salt [(CellTiter 96(R) Aqueous One Solution) cell proliferation reagent, containing the (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium, inner salt) and an electron coupling reagent phenazine ethosulfate], was optimized and qualified for quantitative determination of IL-15 dependent CTLL-2 cell proliferation activity. An in-house recombinant Human (rHu)IL-15 reference lot was standardized (IU/mg) against an international reference standard. Specificity of the assay for IL-15 was documented by illustrating the ability of neutralizing anti-IL-15 antibodies to block the product specific CTLL-2 cell proliferation and the lack of blocking effect with anti-IL-2 antibodies. Under the defined assay conditions, the linear dose-response concentration range was between 0.04 and 0.17ng/ml of the rHuIL-15 produced in-house and 0.5-3.0IU/ml for the international standard. Statistical analysis of the data was performed with the use of scripts written in the R Statistical Language and Environment utilizing a four-parameter logistic regression fit analysis procedure. The overall variation in the ED(50) values for the in-house reference standard from 55 independent estimates performed over the period of 1year was 12.3% of the average. Excellent intra-plate and within-day/inter-plate consistency was observed for all four parameter estimates in the model. Different preparations of rHuIL-15 showed excellent intra-plate consistency in the parameter estimates corresponding to the lower and upper asymptotes as well as to the 'slope' factor at the mid-point. The ED(50) values showed statistically significant differences for different lots and for control versus stressed samples. Three R-scripts improve data analysis capabilities allowing one to describe assay variations, to draw inferences between data sets from formal statistical tests, and to set up improved assay acceptance

  16. SWATH Mass Spectrometry Performance Using Extended Peptide MS/MS Assay Libraries.

    PubMed

    Wu, Jemma X; Song, Xiaomin; Pascovici, Dana; Zaw, Thiri; Care, Natasha; Krisp, Christoph; Molloy, Mark P

    2016-07-01

    The use of data-independent acquisition methods such as SWATH for mass spectrometry based proteomics is usually performed with peptide MS/MS assay libraries which enable identification and quantitation of peptide peak areas. Reference assay libraries can be generated locally through information dependent acquisition, or obtained from community data repositories for commonly studied organisms. However, there have been no studies performed to systematically evaluate how locally generated or repository-based assay libraries affect SWATH performance for proteomic studies. To undertake this analysis, we developed a software workflow, SwathXtend, which generates extended peptide assay libraries by integration with a local seed library and delivers statistical analysis of SWATH-quantitative comparisons. We designed test samples using peptides from a yeast extract spiked into peptides from human K562 cell lysates at three different ratios to simulate protein abundance change comparisons. SWATH-MS performance was assessed using local and external assay libraries of varying complexities and proteome compositions. These experiments demonstrated that local seed libraries integrated with external assay libraries achieve better performance than local assay libraries alone, in terms of the number of identified peptides and proteins and the specificity to detect differentially abundant proteins. Our findings show that the performance of extended assay libraries is influenced by the MS/MS feature similarity of the seed and external libraries, while statistical analysis using multiple testing corrections increases the statistical rigor needed when searching against large extended assay libraries. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  17. Direct /sup 125/I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratcliffe, W.A.; Corrie, J.E.; Dalziel, A.H.

    1982-06-01

    Researchers compared two direct radioimmunoassays for progesterone in 50 microL of unextracted serum or plasma with assays involving extraction of serum. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11 alpha hemisuccinyl conjugate and the radioligand /sup 125/I-labeled progesterone 11 alpha-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r greatermore » than 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. Researchers conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum.« less

  18. Direct /sup 125/I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.

    1982-06-01

    Two direct radioimmunoassays for progesterone in 50 ..mu..L of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11..cap alpha..-hemisuccinyl conjugate and the radioligand /sup 125/I-labeled progesterone 11..cap alpha..-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96)more » with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum.« less

  19. Evaluation of lot-to-lot repeatability and effect of assay media choice in the recombinant Factor C assay.

    PubMed

    McKenzie, Jennifer Helen; Alwis, K Udeni; Sordillo, Joanne E; Kalluri, Kesava Srinivas; Milton, Donald Kirby

    2011-06-01

    Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and assay media, to endotoxin estimates previously obtained by Limulus amebocyte lysate (LAL) assay and amounts of 3-hydroxy fatty acids (3-OHFA) in lipopolysaccharide (LPS) using gas-chromatography mass spectroscopy (GC-MS). We found that lot-to-lot variability of the rFC assay kits does not significantly alter endotoxin estimates in house dust samples when performed using three of the four assay media tested and that choice of assay media significantly altered endotoxin estimates obtained by rFC assay of house dust samples. Our findings demonstrate lot-to-lot reproducibility of rFC assay of environmental samples and suggest that use of rFC assay performed with Tris buffer or water as the extraction and assay medium for measurement of endotoxin in dust samples may be a suitable choice for developing a standardized methodology.

  20. [Hemolytic anemia caused by graft-versus-host reaction in ABO-nonidentical renal transplants from blood group O donors].

    PubMed

    Peces, R; Díaz Corte, C; Navascués, R A

    2001-01-01

    Acute hemolytic anemia is one of the side effects associated with cyclosporin and tacrolimus therapy, and three mechanisms have been described to account for hemolytic anemia in patients receiving these drugs: drug induced hemolysis, autoimmune hemolysis and alloimmune hemolysis resulting from donor lymphocytes derived from the allograft (passenger lymphocyte syndrome). We report four cases of renal transplant recipients who developed alloimmune hemolytic anemia due to minor ABO incompatibility while under treatment with cyclosporin (two) and tacrolimus (two). The anti-erythrocyte antibodies responsible for hemolysis were of the IgG isotype and showed anti-A or anti-B specificity. These findings suggest that the hemolysis could be related to alloantibodies derived from the clonal development of donor B lymphocytes in the recipients (microchimerism). In summary, hemolytic anemia due to ABO-minor incompatibility occurs infrequently after renal transplantation. Risks are higher for patients A, B or AB blood group receiving an O blood group graft under treatment with cyclosporin or tacrolimus. Follow-up of these patients is warranted for the early detection and optimal management may be achieved by reduction of immunosuppression and change to mycophenolate mofetil.

  1. An enzyme-coupled continuous fluorescence assay for farnesyl diphosphate synthases

    PubMed Central

    Dozier, Jonathan K; Distefano, Mark D

    2012-01-01

    Farnesyl diphosphate synthase (FDPS) catalyzes the conversion of isopentenyl diphosphate and dimethylallyl diphosphate to farnesyl diphosphate, a crucial metabolic intermediate in the synthesis of cholesterol, ubiquinone and prenylated proteins; consequently, much effort has gone into developing inhibitors that target FDPS. Currently most FDPS assays use either radiolabeled substrates and are discontinuous, or monitor pyrophosphate release and not farnesyl diphosphate (FPP) creation. Here we report the development of a continuous coupled enzyme assay for FDPS activity that involves the subsequent incorporation of the FPP product of that reaction into a peptide via the action of protein farnesyltransferase (PFTase). By using a dansylated peptide whose fluorescence quantum yield increases upon farnesylation, the rate of FDPS-catalyzed FPP production can be measured. We show that this assay is more sensitive than existing coupled assays, that it can be used to conveniently monitor FDPS activity in a 96-well plate format and that it can reproduce IC50 values for several previously reported FDPS inhibitors. This new method offers a simple, safe and continuous method to assay FDPS activity that should greatly facilitate the screening of inhibitors of this important target. PMID:22085443

  2. A comparative study of PD-L1 immunohistochemical assays with four reliable antibodies in thymic carcinoma.

    PubMed

    Sakane, Tadashi; Murase, Takayuki; Okuda, Katsuhiro; Takino, Hisashi; Masaki, Ayako; Oda, Risa; Watanabe, Takuya; Kawano, Osamu; Haneda, Hiroshi; Moriyama, Satoru; Saito, Yushi; Yamada, Takeshi; Nakanishi, Ryoichi; Inagaki, Hiroshi

    2018-01-23

    Currently, four immunohistochemical assays are registered with the US Food and Drug Administration to detect the expression of PD-L1. We investigated the PD-L1 expression in thymic carcinomas using these four diagnostic assays. The cases of 53 patients were reviewed and their specimens were subjected to four PD-L1 assays with different antibodies (SP142, SP263, 22C3, and 28-8). The PD-L1 expression in tumor cells (TCs) and immune cells (ICs) was evaluated. In TCs, the four assays showed similar scores in each case. Histopathologically, high TC scores were observed in squamous cell carcinomas (SqCCs). Meanwhile, there were no significant relationships among the IC scores in the four assays. In SqCCs, the high expression of PD-L1 (defined as ≥50% TC score) in TCs tended to be associated with early stage cancer. The patients with high expression levels of PD-L1 tended to show longer overall survival in the 22C3 assays (p=0.0200). In thymic carcinomas, the staining pattern showed high concordance among the four assays when TCs - rather than ICs - were stained. High PD-L1 positivity in TCs, especially in SqCCs, indicated that PD-1/PD-L1 targeted therapy may be a promising therapeutic approach.

  3. A comparison of thiolated and disulfide-crosslinked polyethylenimine for nonviral gene delivery.

    PubMed

    Aravindan, Latha; Bicknell, Katrina A; Brooks, Gavin; Khutoryanskiy, Vitaliy V; Williams, Adrian C

    2013-09-01

    Branched polyethylenimine (25 kDa) is thiolated and compared with redox-sensitive crosslinked derivatives. Both polymers thiol contents are assessed; the thiolated polymers have 390-2300 mmol SH groups/mol, whereas the crosslinked polymers have lower thiol contents. Cytotoxicity assays show that both modified polymers give lower hemolysis than unmodified PEI. Increased thiol content increases gene transfer efficiency but also elevates cytotoxicity. Crosslinking improves plasmid DNA condensation and enhances transfection efficiency, but extensive crosslinking overstabilizes the polyplexes and decreases transfection, emphasizing the need to balance polyplex stabilization and unpacking. Thus, at low levels of crosslinking, 25 kDa PEI can be an efficient redox-sensitive carrier system. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A comparison between two brine shrimp assays to detect in vitro cytotoxicity in marine natural products

    PubMed Central

    Carballo, José Luis; Hernández-Inda, Zaira L; Pérez, Pilar; García-Grávalos, María D

    2002-01-01

    Background The brine shrimp lethality assay is considered a useful tool for preliminary assessment of toxicity. It has also been suggested for screening pharmacological activities in plant extracts. However, we think that it is necessary to evaluate the suitability of the brine shrimp methods before they are used as a general bio-assay to test natural marine products for pharmacological activity. Material and Methods The bioactivity of the isopropanolic (2-PrOH) extracts of 14 species of marine invertebrates and 6 species of macroalgae was evaluated with the shrimp lethality assay (lethality assay), as well as with another assay based on the inhibition of hatching of the cyst (hatchability assay). The extracts were also assayed for cytotoxicity against two human cell lines, lung carcinoma A-549 and colon carcinoma HT-29, in order to assess the sensitivity of the shrimp assays to detect cytotoxic activity. Results Two sponges (Hyatella sp, Dysidea sp.), two gorgonians (Pacifigorgia adamsii, Muricea sp.), one tunicate (Polyclinum laxum), and three echinoderms (Holothuria impatiens, Pseudoconus californica and Pharia pyramidata) showed a strong cytostatic (growth inhibition) and cytotoxic effect. The hatchability assay showed a strong activity in 4 of the species active against the two human cell lines tested (Hyatella sp, Dysidea sp., Pacifigorgia adamsii and Muricea sp.), and the lethality assay also showed a high lethality in 4 of them (Pacifigorgia adamsii, Muricea sp., Polyclinum laxum, and Pharia pyramidata). Each bioassay detected activity in 50% of the species that were considered active against the two human cell lines tested. However, the simultaneous use of both bioassays increased the percentage to 75%. Conclusions Our results seem consistent with the correlation previously established between cytotoxicity and brine shrimp lethality in plant extracts. We suggest using both bioassays simultaneously to test natural marine products for pharmacological

  5. Analytical verification and method comparison of the ADVIA Centaur® Intact Parathyroid Hormone assay.

    PubMed

    Fernández-Galán, Esther; Bedini, Josep Lluís; Filella, Xavier

    2017-12-01

    This study is the first verification of the novel iPTH Siemens ADVIA Centaur® Intact Parathyroid Hormone (iPTHm) chemiluminescence immunoassay based on monoclonal antibodies. We also compared the iPTH results obtained using this assay with the previous ADVIA Centaur® Parathyroid Hormone assay (iPTHp) based on polyclonal antibodies. The analytical performance study of iPTHm assay included LoD, LoQ, intra- and inter-assay reproducibility, and linearity. A comparison study was performed on 369 routine plasma samples. The results were analyzed independently for patients with normal and abnormal GFR, as well as patients on hemodialysis. In addition, clinical concordance between assays was assessed. Finally, we studied PTH stability of plasma samples at 4°C. For the iPTHm assay LoD and LoQ were 0.03pmol/L and 0.10pmol/L, respectively. Intra- and inter-assay CV were between 2.3% and 6.2%. Linearity was correct in the range from 3.82 to 203.08pmol/L. Correlation studies showed a good correlation (r=0.99) between iPTHm and iPTHp, with bias of -2.55% (IC -3.48% to -1.62%) in the range from 0.32 to 117.07pmol/L. Clinical concordance, assessed by Kappa Index, was 0.874. The stability study showed that differences compared to basal iPTH concentration did not exceed 20% in any of the samples analyzed. The iPTHm assay demonstrated acceptable performance and a very good clinical concordance with iPTHp assay, currently used in our laboratory. Thus, the novel iPTHm assay can replace the previous iPTHp assay, since results provided by both assays are very similar. In our study, the stability of iPTH is not affected by storage up to 14days. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Quantitative comparison of DNA methylation assays for biomarker development and clinical applications.

    PubMed

    2016-07-01

    DNA methylation patterns are altered in numerous diseases and often correlate with clinically relevant information such as disease subtypes, prognosis and drug response. With suitable assays and after validation in large cohorts, such associations can be exploited for clinical diagnostics and personalized treatment decisions. Here we describe the results of a community-wide benchmarking study comparing the performance of all widely used methods for DNA methylation analysis that are compatible with routine clinical use. We shipped 32 reference samples to 18 laboratories in seven different countries. Researchers in those laboratories collectively contributed 21 locus-specific assays for an average of 27 predefined genomic regions, as well as six global assays. We evaluated assay sensitivity on low-input samples and assessed the assays' ability to discriminate between cell types. Good agreement was observed across all tested methods, with amplicon bisulfite sequencing and bisulfite pyrosequencing showing the best all-round performance. Our technology comparison can inform the selection, optimization and use of DNA methylation assays in large-scale validation studies, biomarker development and clinical diagnostics.

  7. High throughput analysis of red wine and grape phenolics-adaptation and validation of methyl cellulose precipitable tannin assay and modified Somers color assay to a rapid 96 well plate format.

    PubMed

    Mercurio, Meagan D; Dambergs, Robert G; Herderich, Markus J; Smith, Paul A

    2007-06-13

    The methyl cellulose precipitable (MCP) tannin assay and a modified version of the Somers and Evans color assay were adapted to high-throughput (HTP) analysis. To improve efficiency of the MCP tannin assay, a miniaturized 1 mL format and a HTP format using 96 well plates were developed. The Somers color assay was modified to allow the standardization of pH and ethanol concentrations of wine samples in a simple one-step dilution with a buffer solution, thus removing inconsistencies between wine matrices prior to analysis and allowing for its adaptation to a HTP format. Validation studies showed that all new formats were efficient, and results were reproducible and analogous to the original formats.

  8. Comparison of Established and Emerging Biodosimetry Assays

    PubMed Central

    Rothkamm, K.; Beinke, C.; Romm, H.; Badie, C.; Balagurunathan, Y.; Barnard, S.; Bernard, N.; Boulay-Greene, H.; Brengues, M.; De Amicis, A.; De Sanctis, S.; Greither, R.; Herodin, F.; Jones, A.; Kabacik, S.; Knie, T.; Kulka, U.; Lista, F.; Martigne, P.; Missel, A.; Moquet, J.; Oestreicher, U.; Peinnequin, A.; Poyot, T.; Roessler, U.; Scherthan, H.; Terbrueggen, B.; Thierens, H.; Valente, M.; Vral, A.; Zenhausern, F.; Meineke, V.; Braselmann, H.; Abend, M.

    2014-01-01

    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3–0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5–4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools. PMID:23862692

  9. Evaluation of Multiplexed Foot-and-Mouth Disease Nonstructural Protein Antibody Assay Against Standardized Bovine Serum Panel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, J; Parida, S; Clavijo, A

    2007-05-14

    Liquid array technology has previously been used to show proof-of-principle of a multiplexed non structural protein serological assay to differentiate foot-and-mouth infected and vaccinated animals. The current multiplexed assay consists of synthetically produced peptide signatures 3A, 3B and 3D and recombinant protein signature 3ABC in combination with four controls. To determine diagnostic specificity of each signature in the multiplex, the assay was evaluated against a naive population (n = 104) and a vaccinated population (n = 94). Subsequently, the multiplexed assay was assessed using a panel of bovine sera generated by the World Reference Laboratory for foot-and-mouth disease in Pirbright,more » UK. This sera panel has been used to assess the performance of other singleplex ELISA-based non-structural protein antibody assays. The 3ABC signature in the multiplexed assay showed comparative performance to a commercially available non-structural protein 3ABC ELISA (Cedi test{reg_sign}) and additional information pertaining to the relative diagnostic sensitivity of each signature in the multiplex is acquired in one experiment. The encouraging results of the evaluation of the multiplexed assay against a panel of diagnostically relevant samples promotes further assay development and optimization to generate an assay for routine use in foot-and-mouth disease surveillance.« less

  10. Profiling 976 ToxCast Chemicals across 331 Enzymatic and Receptor Signaling Assays

    PubMed Central

    2013-01-01

    Understanding potential health risks is a significant challenge due to the large numbers of diverse chemicals with poorly characterized exposures and mechanisms of toxicities. The present study analyzes 976 chemicals (including failed pharmaceuticals, alternative plasticizers, food additives, and pesticides) in Phases I and II of the U.S. EPA’s ToxCast project across 331 cell-free enzymatic and ligand-binding high-throughput screening (HTS) assays. Half-maximal activity concentrations (AC50) were identified for 729 chemicals in 256 assays (7,135 chemical–assay pairs). Some of the most commonly affected assays were CYPs (CYP2C9 and CYP2C19), transporters (mitochondrial TSPO, norepinephrine, and dopaminergic), and GPCRs (aminergic). Heavy metals, surfactants, and dithiocarbamate fungicides showed promiscuous but distinctly different patterns of activity, whereas many of the pharmaceutical compounds showed promiscuous activity across GPCRs. Literature analysis confirmed >50% of the activities for the most potent chemical–assay pairs (54) but also revealed 10 missed interactions. Twenty-two chemicals with known estrogenic activity were correctly identified for the majority (77%), missing only the weaker interactions. In many cases, novel findings for previously unreported chemical–target combinations clustered with known chemical–target interactions. Results from this large inventory of chemical–biological interactions can inform read-across methods as well as link potential targets to molecular initiating events in adverse outcome pathways for diverse toxicities. PMID:23611293

  11. Use of a flow-cell system to investigate virucidal dimethylmethylene blue phototreatment in two RBC additive solutions.

    PubMed

    Wagner, Stephen; Skripchenko, Andrey; Thompson-Montgomery, Dedeene

    2002-09-01

    Limited photoinactivation kinetics, use of low-volume 30 percent Hct RBCs, and hemolysis have restricted the practicality of the use of dimethylmethylene blue (DMMB) and light for RBC decontamination. A flow-cell system was developed to rapidly treat larger volumes of oxygenated 45 percent Hct RBCs with high-intensity red light. CPD-whole blood was WBC reduced, RBCs were diluted in additive solutions (either Adsol or Erythrosol), and suspensions were subsequently oxygenated by gas overlay. Intracellular or extracellular VSV and DMMB were sequentially added. VSV-infected RBC suspensions (45% Hct) were passed through 1-mm-thick flow cells and illuminated. Samples were titered for VSV, stored for up to 42 days, and assayed for Hb, supernatant potassium, ATP, and MCV. The use of oxygenated RBCs resulted in rapid and reproducible photoinactivaton of > or = 6.6 log extracellular and approximately 4.0 log intracellular VSV independent of additive solution. Phototreated Adsol RBCs exhibited more than 10 times greater hemolysis and 30 percent greater MCV during storage than identically treated Erythrosol RBCs. Phototreatment caused RBC potassium leakage from RBCs in both additive solutions. ATP levels were better preserved in Erythrosol than Adsol RBCs. A rapid, reproducible, and robust method for photoinactivating model virus in RBC suspensions was developed. Despite improved hemolysis and ATP levels in Erythrosol-phototreated RBCs, storage properties were not maintained for 42 days.

  12. Python erythrocytes are resistant to α-hemolysin from Escherichia coli.

    PubMed

    Larsen, Casper K; Skals, Marianne; Wang, Tobias; Cheema, Muhammad U; Leipziger, Jens; Praetorius, Helle A

    2011-12-01

    α-Hemolysin (HlyA) from Escherichia coli lyses mammalian erythrocytes by creating nonselective cation pores in the membrane. Pore insertion triggers ATP release and subsequent P2X receptor and pannexin channel activation. Blockage of either P2X receptors or pannexin channels reduces HlyA-induced hemolysis. We found that erythrocytes from Python regius and Python molurus are remarkably resistant to HlyA-induced hemolysis compared to human and Trachemys scripta erythrocytes. HlyA concentrations that induced maximal hemolysis of human erythrocytes did not affect python erythrocytes, but increasing the HlyA concentration 40-fold did induce hemolysis. Python erythrocytes were more resistant to osmotic stress than human erythrocytes, but osmotic stress tolerance per se did not confer HlyA resistance. Erythrocytes from T. scripta, which showed higher osmotic resistance than python erythrocytes, were as susceptible to HlyA as human erythrocytes. Therefore, we tested whether python erythrocytes lack the purinergic signalling known to amplify HlyA-induced hemolysis in human erythrocytes. P. regius erythrocytes increased intracellular Ca²⁺ concentration and reduced cell volume when exposed to 3 mM ATP, indicating the presence of a P2X₇-like receptor. In addition, scavenging extracellular ATP or blocking P2 receptors or pannexin channels reduced the HlyA-induced hemolysis. We tested whether the low HlyA sensitivity resulted from low affinity of HlyA to the python erythrocyte membrane. We found comparable incorporation of HlyA into human and python erythrocyte membranes. Taken together, the remarkable HlyA resistance of python erythrocytes was not explained by increased osmotic resistance, lack of purinergic hemolysis amplification, or differences in HlyA affinity.

  13. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    PubMed

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  14. First two-reagent vitamin D assay for general clinical chemistry.

    PubMed

    Saida, Fakhri B; Padilla-Chee, Mario; Dou, Chao; Yuan, Chong

    2018-05-01

    Vitamin D is a lipid-soluble molecule that plays key physiological roles in the metabolism of calcium, phosphate and magnesium. Recent studies show that deficiency in vitamin D is linked to cardiovascular diseases, autoimmune diseases and cancer. As a result, regular monitoring of 25-OH vitamin D (the main circulating form of vitamin D) is becoming essential. Current 25-OH vitamin D testing methodologies are cumbersome (too many reagents, long incubation times, phase separation) and are not compatible with general clinical chemistry platforms. Here, we report on a novel method to detect 25-OH vitamin D that is fast (results in 10 min or less), simple (two reagents) and compatible with virtually all general clinical chemistry analyzers. An immunoturbidimetric assay for 25-OH vitamin D (the Diazyme EZ Vitamin D Assay) has been developed using nanoparticles and vitamin D-specific antibodies. The performance of the assay kit, which consists of two reagents and five calibrators, was tested on the Beckman AU680 analyzer (AU680). The new assay was precise, sensitive (LOD = 7.2 nmol/L), linear (up to 390.1 nmol/L) and correlated strongly (R 2  > 0.95) with major commercial 25-OH vitamin D assays. Additionally, the assay was found to be the fastest to date, with the first results obtained within 10 min. Throughput on the AU680 was estimated at over 300 tests per hour. The newly developed 25-OH vitamin D assay is fast, precise and accurate. It can be run on most general chemistry analyzers. This assay aims at providing vitamin D-testing capabilities to all clinical chemistry laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Performance of PCR-based and Bioluminescent assays for mycoplasma detection.

    PubMed

    Falagan-Lotsch, Priscila; Lopes, Talíria Silva; Ferreira, Nívea; Balthazar, Nathália; Monteiro, Antônio M; Borojevic, Radovan; Granjeiro, José Mauro

    2015-11-01

    Contaminated eukaryotic cell cultures are frequently responsible for unreliable results. Regulatory entities request that cell cultures must be mycoplasma-free. Mycoplasma contamination remains a significant problem for cell cultures and may have an impact on biological analysis since they affect many cell parameters. The gold standard microbiological assay for mycoplasma detection involves laborious and time-consuming protocols. PCR-based and Bioluminescent assays have been considered for routine cell culture screening in research laboratories since they are fast, easy and sensitive. Thus, the aim of this work is to compare the performance of two popular commercial assays, PCR-based and Bioluminescent assays, by assessing the level of mycoplasma contamination in cell cultures from Rio de Janeiro Cell Bank (RJCB) and also from customers' laboratories. The results obtained by both performed assays were confirmed by scanning electron microscopy. In addition, we evaluated the limit of detection of the PCR kit under our laboratory conditions and the storage effects on mycoplasma detection in frozen cell culture supernatants. The performance of both assays for mycoplasma detection was not significantly different and they showed very good agreement. The Bioluminescent assay for mycoplasma detection was slightly more dependable than PCR-based due to the lack of inconclusive results produced by the first technique, especially considering the ability to detect mycoplasma contamination in frozen cell culture supernatants. However, cell lines should be precultured for four days or more without antibiotics to obtain safe results. On the other hand, a false negative result was obtained by using this biochemical approach. The implementation of fast and reliable mycoplasma testing methods is an important technical and regulatory issue and PCR-based and Bioluminescent assays may be good candidates. However, validation studies are needed. Copyright © 2015 Elsevier B.V. All rights

  16. A Novel Isothermal Assay of Borrelia burgdorferi by Recombinase Polymerase Amplification with Lateral Flow Detection.

    PubMed

    Liu, Wei; Liu, Hui-Xin; Zhang, Lin; Hou, Xue-Xia; Wan, Kang-Lin; Hao, Qin

    2016-08-03

    A novel isothermal detection for recombinase polymerase amplification with lateral flow (LF-RPA) was established for Borrelia burgdorferi (B. burgdorferi) detection in this study. This assay with high sensitivity and specificity can get a visible result without any additional equipment in 30 min. We designed a pair of primers according to recA gene of B. burgdorferi strains and a methodology evaluation was performed. The results showed that the RPA assay based on the recA gene was successfully applied in B. burgdorferi detection, and its specific amplification was only achieved from the genomic DNA of B. burgdorferi. The detection limit of the new assay was about 25 copies of the B. burgdorferi genomic DNA. Twenty Lyme borreliosis patients' serum samples were detected by LF-RPA assay, real-time qPCR and nested-PCR. Results showed the LF-RPA assay is more effective than nested-PCR for its shorter reaction time and considerably higher detection rate. This method is of great value in clinical rapid detection for Lyme borreliosis. Using the RPA assay might be a megatrend for DNA detection in clinics and endemic regions.

  17. Microvolume, kinetic-dependent enzyme-linked immunosorbent assay for amoeba antibodies.

    PubMed Central

    Mathews, H M; Walls, K W; Huong, A Y

    1984-01-01

    We describe a microvolume enzyme-linked immunosorbent assay based on enzyme rate kinetics. Antigens from Entamoeba histolytica were adsorbed in wells of disposable polystyrene strips containing 12 flat-bottom wells. After exposure to the serum of a patient and peroxidase-labeled anti-human immunoglobulin G, the rate of color change in specific substrate was determined by eight sequential readings of individual wells over a 2-min period with a microcomputer-controlled model MR-600 automated plate reader. The changes in absorbance readings were converted to slope values for each well by the microcomputer. Thus, 12 samples were read, and results were printed in ca. 3.5 min. Assay conditions are described and data are presented to show that this assay is quantitative for antibody and antigen concentration with a single-tube (well) dilution. PMID:6321547

  18. Effects of Storage of CPD-ADSOL Red Cells at 4C for as Long as 49 Days, Biochemical Modification, Freeze-Preservation, and Post-Wash Storage at 4C for 24 Hours

    DTIC Science & Technology

    1992-05-27

    DPG, P50 levels , and the level of residual hemolysis were satisfactory. Our data show that 42-days is the maximum period that red blood cells can...survival value of only 61%, but ATP, DPG, P50 levels and the level of residual hemolysis were satisfactory. Our data show that 42-days is the maximum...collected red blood cells are stored at 4C for less than 2 weeks, the rejuventation process increases the red cell 2,3 DPG level to 250% of normal and the

  19. Magneto immunofluorescence assay for diagnosis of celiac disease.

    PubMed

    Kergaravat, Silvina V; Beltramino, Luis; Garnero, Nidia; Trotta, Liliana; Wagener, Marta; Fabiano, Silvia N; Pividori, Maria Isabel; Hernandez, Silvia R

    2013-10-10

    A magneto immunofluorescence assay for the detection of anti-transglutaminase antibodies (ATG2) in celiac disease was developed. The ATG2 were recognized by transglutaminase enzyme immobilized on the magnetic beads and then the immunological reaction was revealed by antibodies labeled with peroxidase. The fluorescent response of the enzymatic reaction with o-phenylenediamine and H2O2 as substrates was correlated with anti-transglutaminase titer, showing EC50 and LOD values of 1:11,600 and 1:74,500 of antibody titers, respectively. A total number of 29 sera samples from clinically confirmed cases of celiac disease and 19 negative control samples were tested by the novel magneto immunofluorescence assay. The data were submitted to the receiver-operating characteristic plot (ROC) analysis which indicated that 8.1 U was the most effective cut-off value to discriminate correctly between celiac and non-celiac patients. The immunofluorescence assay exhibited a sensitivity of 96.6%, a specificity of 89.5% and an efficiency 93.8% compared with the commercial optical ELISA kit. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. A multiparametric assay for quantitative nerve regeneration evaluation.

    PubMed

    Weyn, B; van Remoortere, M; Nuydens, R; Meert, T; van de Wouwer, G

    2005-08-01

    We introduce an assay for the semi-automated quantification of nerve regeneration by image analysis. Digital images of histological sections of regenerated nerves are recorded using an automated inverted microscope and merged into high-resolution mosaic images representing the entire nerve. These are analysed by a dedicated image-processing package that computes nerve-specific features (e.g. nerve area, fibre count, myelinated area) and fibre-specific features (area, perimeter, myelin sheet thickness). The assay's performance and correlation of the automatically computed data with visually obtained data are determined on a set of 140 semithin sections from the distal part of a rat tibial nerve from four different experimental treatment groups (control, sham, sutured, cut) taken at seven different time points after surgery. Results show a high correlation between the manually and automatically derived data, and a high discriminative power towards treatment. Extra value is added by the large feature set. In conclusion, the assay is fast and offers data that currently can be obtained only by a combination of laborious and time-consuming tests.

  1. Biosensors: Viruses for ultrasensitive assays

    NASA Astrophysics Data System (ADS)

    Donath, Edwin

    2009-04-01

    A three-dimensional assay based on genetically engineered viral nanoparticles and nickel nanohairs can detect much lower levels of protein markers associated with heart attacks than conventional assays.

  2. Clonogenic assay: adherent cells.

    PubMed

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  3. Clonogenic Assay: Adherent Cells

    PubMed Central

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T.; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C.

    2011-01-01

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 19561. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture1. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811)2. Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  4. Genotoxicity testing: Comparison of the γH2AX focus assay with the alkaline and neutral comet assays.

    PubMed

    Nikolova, Teodora; Marini, Federico; Kaina, Bernd

    2017-10-01

    Genotoxicity testing relies on the quantitative measurement of adverse effects, such as chromosome aberrations, micronuclei, and mutations, resulting from primary DNA damage. Ideally, assays will detect DNA damage and cellular responses with high sensitivity, reliability, and throughput. Several novel genotoxicity assays may fulfill these requirements, including the comet assay and the more recently developed γH2AX assay. Although they are thought to be specific for genotoxicants, a systematic comparison of the assays has not yet been undertaken. In the present study, we compare the γH2AX focus assay with the alkaline and neutral versions of the comet assay, as to their sensitivities and limitations for detection of genetic damage. We investigated the dose-response relationships of γH2AX foci and comet tail intensities at various times following treatment with four prototypical genotoxicants, methyl methanesulfonate (MMS), N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), mitomycin C, and hydrogen peroxide (H 2 O 2 ) and we tested whether there is a correlation between the endpoints, i.e., alkali-labile sites and DNA strand breaks on the one hand and the cell's response to DNA double-strand breaks and blocked replication forks on the other. Induction of γH2AX foci gave a linear dose response and all agents tested were positive in the assay. The increase in comet tail intensity was also a function of dose; however, mitomycin C was almost completely ineffective in the comet assay, and the doses needed to achieve a significant effect were somewhat higher for some treatments in the comet assay than in the γH2AX foci assay, which was confirmed by threshold analysis. There was high correlation between tail intensity and γH2AX foci for MMS and H 2 O 2 , less for MNNG, and none for mitomycin C. From this we infer that the γH2AX foci assay is more reliable, sensitive, and robust than the comet assay for detecting genotoxicant-induced DNA damage. Copyright © 2017 Elsevier

  5. 21 CFR 864.7250 - Erythropoietin assay.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... assay. (a) Identification. A erythropoietin assay is a device that measures the concentration of erythropoietin (an enzyme that regulates the production of red blood cells) in serum or urine. This assay provides diagnostic information for the evaluation of erythrocytosis (increased total red cell mass) and...

  6. 21 CFR 864.7250 - Erythropoietin assay.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... assay. (a) Identification. A erythropoietin assay is a device that measures the concentration of erythropoietin (an enzyme that regulates the production of red blood cells) in serum or urine. This assay provides diagnostic information for the evaluation of erythrocytosis (increased total red cell mass) and...

  7. 21 CFR 864.7250 - Erythropoietin assay.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... assay. (a) Identification. A erythropoietin assay is a device that measures the concentration of erythropoietin (an enzyme that regulates the production of red blood cells) in serum or urine. This assay provides diagnostic information for the evaluation of erythrocytosis (increased total red cell mass) and...

  8. 21 CFR 864.7250 - Erythropoietin assay.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... assay. (a) Identification. A erythropoietin assay is a device that measures the concentration of erythropoietin (an enzyme that regulates the production of red blood cells) in serum or urine. This assay provides diagnostic information for the evaluation of erythrocytosis (increased total red cell mass) and...

  9. 21 CFR 864.7250 - Erythropoietin assay.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... assay. (a) Identification. A erythropoietin assay is a device that measures the concentration of erythropoietin (an enzyme that regulates the production of red blood cells) in serum or urine. This assay provides diagnostic information for the evaluation of erythrocytosis (increased total red cell mass) and...

  10. Development of a Panel of Recombinase Polymerase Amplification Assays for Detection of Biothreat Agents

    PubMed Central

    Euler, Milena; Wang, Yongjie; Heidenreich, Doris; Patel, Pranav; Strohmeier, Oliver; Hakenberg, Sydney; Niedrig, Matthias; Hufert, Frank T.

    2013-01-01

    Syndromic panels for infectious disease have been suggested to be of value in point-of-care diagnostics for developing countries and for biodefense. To test the performance of isothermal recombinase polymerase amplification (RPA) assays, we developed a panel of 10 RPAs for biothreat agents. The panel included RPAs for Francisella tularensis, Yersinia pestis, Bacillus anthracis, variola virus, and reverse transcriptase RPA (RT-RPA) assays for Rift Valley fever virus, Ebola virus, Sudan virus, and Marburg virus. Their analytical sensitivities ranged from 16 to 21 molecules detected (probit analysis) for the majority of RPA and RT-RPA assays. A magnetic bead-based total nucleic acid extraction method was combined with the RPAs and tested using inactivated whole organisms spiked into plasma. The RPA showed comparable sensitivities to real-time RCR assays in these extracts. The run times of the assays at 42°C ranged from 6 to 10 min, and they showed no cross-detection of any of the target genomes of the panel nor of the human genome. The RPAs therefore seem suitable for the implementation of syndromic panels onto microfluidic platforms. PMID:23345286

  11. A lateral electrophoretic flow diagnostic assay

    PubMed Central

    Lin, Robert; Skandarajah, Arunan; Gerver, Rachel E.; Neira, Hector D.; Fletcher, Daniel A.

    2015-01-01

    Immunochromatographic assays are a cornerstone tool in disease screening. To complement existing lateral flow assays (based on wicking flow) we introduce a lateral flow format that employs directed electrophoretic transport. The format is termed a “lateral e-flow assay” and is designed to support multiplexed detection using immobilized reaction volumes of capture antigen. To fabricate the lateral e-flow device, we employ mask-based UV photopatterning to selectively immobilize unmodified capture antigen along the microchannel in a barcode-like pattern. The channel-filling polyacrylamide hydrogel incorporates a photoactive moiety (benzophenone) to immobilize capture antigen to the hydrogel without a priori antigen modification. We report a heterogeneous sandwich assay using low-power electrophoresis to drive biospecimen through the capture antigen barcode. Fluorescence barcode readout is collected via a low-resource appropriate imaging system (CellScope). We characterize lateral e-flow assay performance and demonstrate a serum assay for antibodies to the hepatitis C virus (HCV). In a pilot study, the lateral e-flow assay positively identifies HCV+ human sera in 60 min. The lateral e-flow assay provides a flexible format for conducting multiplexed immunoassays relevant to confirmatory diagnosis in near-patient settings. PMID:25608872

  12. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    PubMed

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  13. Assessment of the microscreen phage-induction assay for screening hazardous wastes (1989)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Houk, V.S.; DeMarini, D.M.

    1989-01-01

    The Microscreen phage-induction assay, which quantitatively measures the induction of prophage Lambda in Escherichia coli WP2s(Lambda), was used to test 14 crude (unfractionated) hazardous industrial-waste samples for genotoxic activity in the presence and absence of metabolic activation. Eleven of the 14 wastes induced prophage, and induction was observed at concentrations as low as 0.4 picograms per ml. Comparisons of the mutagenic activity of these waste samples in Salmonella and their ability to induce prophage Lambda indicate that the phage-induction assay was a more-sensitive indicator of genetic damage for this group of wastes. All but one of the wastes that weremore » mutagenic to Salmonella were detected by the phage-induction assay, and 5 wastes not mutagenic to Salmonella were genetically active in the phage assay. The enhanced ability of the phage-induction assay to detect genotoxic activity may be related to the constituents comprising these waste samples. Partial chemical characterizations of the wastes showed high concentrations of carcinogenic metals, solvents, and chlorinated compounds, most of which are detected poorly by the Salmonella assay.« less

  14. Evaluation of Assays for Measurement of Serum (Anti)oxidants in Hemodialysis Patients

    PubMed Central

    Jansen, Eugene H. J. M.; Antarorov, Risto

    2014-01-01

    Background. Various biomarkers and assays have been used for assessment of (anti)oxidant status in hemodialysis patients, including those intended for measurement of serum total (anti)oxidants, most often as a part of panel biomarkers. Methods. Serum (anti)oxidant status was measured in 32 chronically hemodialyzed patients and in 47 healthy persons, using two oxidations and three antioxidant assays. Results. The patients before the hemodialysis session have had higher values of total oxidants in comparison to the healthy persons, with a further increase during the hemodialysis. These findings were confirmed with both oxidation assays, but they differ in the percentage of increase and the statistical significance. All three antioxidant assays showed significantly higher values of the total serum antioxidants in the patients before the hemodialysis session in comparison to the healthy persons, and their significant decrease during the hemodialysis. However, the assays differ in the percentage of decrease, its statistical significance, and the correlations with uric acid. Conclusion. The variability of results of total (anti)oxidants which are obtained using different assays should be taken into account when interpreting data from clinical studies of oxidative stress, especially in complex pathologies such as chronic hemodialysis. PMID:24982909

  15. Luminogenic cytochrome P450 assays.

    PubMed

    Cali, James J; Ma, Dongping; Sobol, Mary; Simpson, Daniel J; Frackman, Susan; Good, Troy D; Daily, William J; Liu, David

    2006-08-01

    Luminogenic cytochrome P450 (CYP) assays couple CYP enzyme activity to firefly luciferase luminescence in a technology called P450-Glo(TM) (Promega). Luminogenic substrates are used in assays of human CYP1A1, -1A2, -1B1, -2C8, -2C9, -2C19, -2D6, -2J2, -3A4, -3A7, -4A11, -4F3B, -4F12 and -19. The assays detect dose-dependent CYP inhibition by test compounds against recombinant CYP enzymes or liver microsomes. Induction or inhibition of CYP activities in cultured hepatocytes is measured in a nonlytic approach that leaves cells intact for additional analysis. Luminogenic CYP assays offer advantages of speed and safety over HPLC and radiochemical-based methods. Compared with fluorogenic methods the approach offers advantages of improved sensitivity and decreased interference between optical properties of test compound and CYP substrate. These homogenous assays are sensitive and robust tools for high-throughput CYP screening in early drug discovery.

  16. Characterization of pharmacological properties of isolated single-stranded DNA aptamers against angiotensin II.

    PubMed

    Heiat, Mohammad; Ranjbar, Reza; Fasihi-Ramandi, Mahdi; Latifi, Ali Mohammad; Rasaee, Mohammad Javad

    2016-08-01

    Nucleic acid aptamers can be served as drugs, carriers and diagnostic probes in living systems. Before recruiting aptamers, their pharmacological characteristics should be determined. Here we intended to investigate four important properties of isolated ssDNA anti-angiotensin II aptamers (FLC112 and FLC125) including hemolytic activity, cytotoxicity, immunogenicity and serum stability through in vitro and in vivo models. The hemolytic effect and cytotoxicity potential of aptamers were measured through hemolysis test and MTT assay respectively. In the following test, the humoral immune responses to aptamers in BALB/c mice were assessed. The human serum stability of aptamers was also determined using real-time PCR (qPCR). The results of this study revealed that the FLC112 aptamer with its unique structure had slightly higher cytotoxicity and hemolysis effect (9.14% and 0.1 ± 0.037% respectively) relative to FLC125 (8.07% and 0.08 ± 0.045% respectively) at the highest concentration (5 μM). FLC112 showed ignorable immune response in mice and barely higher than FLC125. Serum stability test confirmed that FLC112 with 12 h had more nuclease stability than FLC125 with 8 h. Aptamer molecule analysis revealed that the structure, sequense composition and motifs are the determinative parameters in aptamer pharmacological properties. Copyright © 2016. Published by Elsevier Ltd.

  17. Flexible Label-Free Quantitative Assay for Antibodies to Influenza Virus Hemagglutinins ▿

    PubMed Central

    Carney, Paul J.; Lipatov, Aleksandr S.; Monto, Arnold S.; Donis, Ruben O.; Stevens, James

    2010-01-01

    During the initial pandemic influenza H1N1 virus outbreak, assays such as hemagglutination inhibition and microneutralization provided important information on the relative protection afforded by the population's cross-reactivity from prior infections and immunizations with seasonal vaccines. However, these assays continue to be limited in that they are difficult to automate for high throughput, such as in pandemic situations, as well as to standardize between labs. Thus, new technologies are being sought to improve standardization, reliability, and throughput by using chemically defined reagents rather than whole cells and virions. We now report the use of a cell-free and label-free flu antibody biosensor assay (f-AbBA) for influenza research and diagnostics that utilizes recombinant hemagglutinin (HA) in conjunction with label-free biolayer interferometry technology to measure biomolecular interactions between the HA and specific anti-HA antibodies or sialylated ligands. We evaluated f-AbBA to determine anti-HA antibody binding activity in serum or plasma to assess vaccine-induced humoral responses. This assay can reveal the impact of antigenic difference on antibody binding to HA and also measure binding to different subtypes of HA. We also show that the biosensor assay can measure the ability of HA to bind a model sialylated receptor-like ligand. f-AbBA could be used in global surveillance laboratories since preliminary tests on desiccated HA probes showed no loss of activity after >2 months in storage at room temperature, indicating that the same reagent lots could be used in different laboratories to minimize interlaboratory assay fluctuation. Future development of such reagents and similar technologies may offer a robust platform for future influenza surveillance activities. PMID:20660137

  18. Multiplex PCR assay to identify methicillin-resistant Staphylococcus haemolyticus.

    PubMed

    Schuenck, Ricardo P; Pereira, Eliezer M; Iorio, Natalia L P; Dos Santos, Kátia R N

    2008-04-01

    Staphylococcus haemolyticus is the most frequently coagulase-negative Staphylococcus species associated with antimicrobial resistance isolated from nosocomial infections. We developed an accurate and simple multiplex PCR assay to identify methicillin-resistant S. haemolyticus (MRSH) isolates. We designed species-specific primers of the mvaA gene that encodes a 3-hydroxy-3-methylglutaryl coenzyme A involved in the mevalonate pathway of the microorganism. Simultaneously, mecA gene primers of methicillin resistance were also used. The PCR assay was established using 16 strains of different reference Staphylococcus species and validated with a collection of 147 clinical staphylococcal isolates that were also phenotypically characterized. Reliable results for the detection of MRSH isolates were obtained for 100% of the strains evaluated, showing that this PCR assay can be used for the routine microbiology laboratories. This is the first report using species-specific multiplex PCR to detect a single segment of S. haemolyticus associated with a segment of mecA gene.

  19. A sensitive branched DNA HIV-1 signal amplification viral load assay with single day turnaround.

    PubMed

    Baumeister, Mark A; Zhang, Nan; Beas, Hilda; Brooks, Jesse R; Canchola, Jesse A; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R

    2012-01-01

    Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) ("Versant Assay") currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16-18 h to 2.5 h, composition of only the "Lysis Diluent" solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements.

  20. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.

    PubMed

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2016-04-01

    We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was <5%. Fujirebio 25(OH)D assay showed the highest correlation among the assays tested with the LC-MS/MS method (R=0.986). The mean relative bias obtained was -15.6% (Fujirebio), -12.7% (Beckman), -2.1% (Abbott) and 9.7% (Roche) as compared to LC-MS/MS. Comparison with the Labquality certified reference serum panel yielded a mean bias of -11.8% (Fujirebio), -14.1% (Beckman), 4.4% (Abbott) and 3.2% (Roche), respectively. Compared to LC-MS/MS, the sensitivity of different methods in detecting vitamin D insufficiency (<50 nmol/L) varied from 100% for the Fujirebio assay to 72.7% for Roche, and specificity ranged from 94.4% for Roche to 87.6% for Beckman. The Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.

  1. Determination of the folate content in cladodes of nopal (Opuntia ficus indica) by microbiological assay utilizing Lactobacillus casei (ATCC 7469) and enzyme-linked immunosorbent assay.

    PubMed

    Ortiz-Escobar, Tania Breshkovskaya; Valverde-González, Maria Elena; Paredes-López, Octavio

    2010-05-26

    Prickly pear cactus has been an important food source in Mexico since ancient times due to its economical and ecological benefits and potential nutraceutical value. Nevertheless, studies on the nutritional aspects and health benefits have been scarce. The purpose of this study was to assess, apparently for the first time, the folate contents of cladodes of nopal by a microbiological assay, using Lactobacillus casei (ATCC 7469) in extracts that were enzymatically treated to release the bound vitamin, employing single, dual, and trienzymatic procedures, and using the enzyme-linked immunosorbent assay (ELISA). We used Opuntia cladodes of different length sizes. The microbiological assay showed some differences among enzyme treatments and sizes of nopal; the trienzyme treatment (alpha-amylase-protease-conjugase) was more efficient in determining the folate content in nopal, giving 5.0 ng/g in the small size cladodes at 54 h of testing time, while ELISA showed no significant differences in the folate content among sizes of cladodes (5.5-5.62 ng/g at 0 min testing time). Both techniques may be used for the assessment of folate content in cladodes, but ELISA is more rapid and reliable.

  2. Evaluation of a Noncontact, Alternative Mosquito Repellent Assay System.

    PubMed

    Tisgratog, Rungarun; Kongmee, Monthathip; Sanguanpong, Unchalee; Prabaripai, Atchariya; Bangs, Michael J; Chareonviriyaphap, Theeraphap

    2016-09-01

    A novel noncontact repellency assay system (NCRAS) was designed and evaluated as a possible alternative method for testing compounds that repel or inhibit mosquitoes from blood feeding. Deet and Aedes aegypti were used in a controlled laboratory setting. Using 2 study designs, a highly significant difference were seen between deet-treated and untreated skin placed behind the protective screens, indicating that deet was detected and was acting as a deterrence to mosquito landing and probing behavior. However, a 2nd study showed significant differences between protected (behind a metal screen barrier) and unprotected (exposed) deet-treated forearms, indicating the screen mesh might restrict the detection of deet and thus influences landing/biting response. These findings indicate the prototype NCRAS shows good promise but requires further evaluation and possible modification in design and testing protocol to achieve more desirable operational attributes in comparison with direct skin-contact repellency mosquito assays.

  3. Assays for Determination of Protein Concentration.

    PubMed

    Olson, Bradley J S C

    2016-06-01

    Biochemical analysis of proteins relies on accurate quantification of protein concentration. Detailed in this appendix are some commonly used methods for protein analysis, e.g., Lowry, Bradford, bicinchoninic acid (BCA), UV spectroscopic, and 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde (CBQCA) assays. The primary focus of this report is assay selection, emphasizing sample and buffer compatibility. The fundamentals of generating protein assay standard curves and of data processing are considered, as are high-throughput adaptations of the more commonly used protein assays. Also included is a rapid, inexpensive, and reliable BCA assay of total protein in SDS-PAGE sample buffer that is used for equal loading of SDS-PAGE gels. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  4. Quantifiable Lateral Flow Assay Test Strips

    NASA Technical Reports Server (NTRS)

    2003-01-01

    As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.

  5. Pharmacological characterization of a fluorescent uptake assay for the noradrenaline transporter.

    PubMed

    Haunsø, Anders; Buchanan, Dawn

    2007-04-01

    The noradrenaline transporter (NET) is a Na(+)/Cl(-) dependent monoamine transporter that mediates rapid clearance of noradrenaline from the synaptic cleft, thereby terminating neuronal signaling. NET is an important target for drug development and is known to be modulated by many psychoactive compounds, including psychostimulants and antidepressants. Here, the authors describe the development and pharmacological characterization of a nonhomogeneous fluorescent NET uptake assay using the compound 4-(4-dimethylaminostyryl)-N-methylpyridinium (ASP(+)). Data presented show that the pharmacology of both the classic radiolabeled (3)H-noradrenaline- and ASP(+)-based uptake assays are comparable, with an excellent correlation between potency obtained for known modulators of NET (r = 0.95, p < 0.0001). Furthermore, the fluorescent uptake assay is highly reproducible and has sufficiently large Z' values to be amenable for high-throughput screening (HTS). The advantage of this assay is compatibility with both 96- and 384-well formats and lack of radioactivity usage. Thus, the authors conclude that the assay is an inexpensive, viable approach for the identification and pharmacological profiling of small-molecule modulators of the monoamine transporter NET and may be amenable for HTS.

  6. High-dose hook effect in six automated human chorionic gonadotrophin assays.

    PubMed

    Al-Mahdili, Huda A; Jones, Graham R D

    2010-07-01

    The high-dose hook effect is a well-known phenomenon of two-site immunoassays including those for human chorionic gonadotrophin (hCG). We investigated the occurrence of a high-dose hook effect in six routinely available hCG assays using a sample with a total hCG concentration of approximately 3,600,000 IU/L. Dilutions of a sample with high hCG concentration were analysed using six common methods: Advia Centaur, Immulite 2000, Dimension RxL, Unicel DxI 800, Roche E170 and Abbott Architect. The measured concentrations and corresponding assay signals were obtained for each method. Performance was compared with manufacturer claims. Four of the tested platforms demonstrated a clear high-dose hook effect, while the other methods showed no hook effect at the highest level tested. Our results indicate that the hook effect may occur in some hCG assays, although the risk of reporting falsely low results was in most cases at higher concentrations than those indicated in manufacturers' product information. Assay design plays a major role in its occurrence. Laboratories should be aware of the assay limitations in this regard.

  7. Assay Design Affects the Interpretation of T-Cell Receptor Gamma Gene Rearrangements

    PubMed Central

    Cushman-Vokoun, Allison M.; Connealy, Solomon; Greiner, Timothy C.

    2010-01-01

    Interpretation of capillary electrophoresis results derived from multiplexed fluorochrome-labeled primer sets can be complicated by small peaks, which may be incorrectly interpreted as clonal T-cell receptor-γ gene rearrangements. In this report, different assay designs were used to illustrate how design may adversely affect specificity. Ten clinical cases, with subclonal peaks containing one of the two infrequently used joining genes, were identified with a tri-color, one-tube assay. The DNA was amplified with the same NED fluorochrome on all three joining primers, first combined (one-color assay) and then amplified separately using a single NED-labeled joining primer. The single primer assay design shows how insignificant peaks could easily be wrongly interpreted as clonal T-cell receptor-γ gene rearrangements. Next, the performance of the one-tube assay was compared with the two-tube BIOMED-2-based TCRG Gene Clonality Assay in a series of 44 cases. Whereas sensitivity was similar between the two methods (92.9% vs. 96.4%; P = 0.55), specificity was significantly less in the BIOMED-2 assay (87.5% vs. 56.3%; P = 0.049) when a 2× ratio was used to define clonality. Specificity was improved to 81.3% by the use of a 5× peak height ratio (P = 0.626). These findings illustrate how extra caution is needed in interpreting a design with multiple, separate distributions, which is more difficult to interpret than a single distribution assay. PMID:20959612

  8. Assessing assay agreement estimation for multiple left-censored data: a multiple imputation approach.

    PubMed

    Lapidus, Nathanael; Chevret, Sylvie; Resche-Rigon, Matthieu

    2014-12-30

    Agreement between two assays is usually based on the concordance correlation coefficient (CCC), estimated from the means, standard deviations, and correlation coefficient of these assays. However, such data will often suffer from left-censoring because of lower limits of detection of these assays. To handle such data, we propose to extend a multiple imputation approach by chained equations (MICE) developed in a close setting of one left-censored assay. The performance of this two-step approach is compared with that of a previously published maximum likelihood estimation through a simulation study. Results show close estimates of the CCC by both methods, although the coverage is improved by our MICE proposal. An application to cytomegalovirus quantification data is provided. Copyright © 2014 John Wiley & Sons, Ltd.

  9. A novel reporter system for neutralizing and enhancing antibody assay against dengue virus.

    PubMed

    Song, Ke-Yu; Zhao, Hui; Jiang, Zhen-You; Li, Xiao-Feng; Deng, Yong-Qiang; Jiang, Tao; Zhu, Shun-Ya; Shi, Pei-Yong; Zhang, Bo; Zhang, Fu-Chun; Qin, E-De; Qin, Cheng-Feng

    2014-02-18

    Dengue virus (DENV) still poses a global public health threat, and no vaccine or antiviral therapy is currently available. Antibody plays distinct roles in controlling DENV infections. Neutralizing antibody is protective against DENV infection, whereas sub-neutralizing concentration of antibody can increase DENV infection, termed antibody-dependent enhancement (ADE). Plaque-based assay represents the most widely accepted method measuring neutralizing or enhancing antibodies. In this study, a novel reporter virus-based system was developed for measuring neutralization and ADE activity. A stable Renilla luciferase reporter DENV (Luc-DENV) that can produce robust luciferase signals in BHK-21 and K562 cells were used to establish the assay and validated against traditional plaque-based assay. Luciferase value analysis using various known DENV-specific monoclonal antibodies showed good repeatability and a well linear correlation with conventional plaque-based assays. The newly developed assay was finally validated with clinical samples from infected animals and individuals. This reporter virus-based assay for neutralizing and enhancing antibody evaluation is rapid, lower cost, and high throughput, and will be helpful for laboratory detection and epidemiological investigation for DENV antibodies.

  10. Hemolytic, anticancer and antigiardial activity of Palythoa caribaeorum venom.

    PubMed

    Lazcano-Pérez, Fernando; Zavala-Moreno, Ariana; Rufino-González, Yadira; Ponce-Macotela, Martha; García-Arredondo, Alejandro; Cuevas-Cruz, Miguel; Gómez-Manzo, Saúl; Marcial-Quino, Jaime; Arreguín-Lozano, Barbarín; Arreguín-Espinosa, Roberto

    2018-01-01

    Cnidarian venoms and extracts have shown a broad variety of biological activities including cytotoxic, antibacterial and antitumoral effects. Most of these studied extracts were obtained from sea anemones or jellyfish. The present study aimed to determine the toxic activity and assess the antitumor and antiparasitic potential of Palythoa caribaeorum venom by evaluating its in vitro toxicity on several models including human tumor cell lines and against the parasite Giardia intestinalis . The presence of cytolysins and vasoconstrictor activity of P. caribaeorum venom were determined by hemolysis, PLA 2 and isolated rat aortic ring assays, respectively. The cytotoxic effect was tested on HCT-15 (human colorectal adenocarcinoma), MCF-7 (human mammary adenocarcinoma), K562 (human chronic myelogenous leukemia), U251 (human glyoblastoma), PC-3 (human prostatic adenocarcinoma) and SKLU-1 (human lung adenocarcinoma). An in vivo toxicity assay was performed with crickets and the antiparasitic assay was performed against G. intestinalis at 24 h of incubation. P. caribaeorum venom produced hemolytic and PLA 2 activity and showed specific cytotoxicity against U251 and SKLU-1 cell lines, with approximately 50% growing inhibition. The venom was toxic to insects and showed activity against G. intestinalis in a dose-dependent manner by possibly altering its membrane osmotic equilibrium. These results suggest that P. caribaeorum venom contains compounds with potential therapeutic value against microorganisms and cancer.

  11. A Sensitive Branched DNA HIV-1 Signal Amplification Viral Load Assay with Single Day Turnaround

    PubMed Central

    Baumeister, Mark A.; Zhang, Nan; Beas, Hilda; Brooks, Jesse R.; Canchola, Jesse A.; Cosenza, Carlo; Kleshik, Felix; Rampersad, Vinod; Surtihadi, Johan; Battersby, Thomas R.

    2012-01-01

    Branched DNA (bDNA) is a signal amplification technology used in clinical and research laboratories to quantitatively detect nucleic acids. An overnight incubation is a significant drawback of highly sensitive bDNA assays. The VERSANT® HIV-1 RNA 3.0 Assay (bDNA) (“Versant Assay”) currently used in clinical laboratories was modified to allow shorter target incubation, enabling the viral load assay to be run in a single day. To dramatically reduce the target incubation from 16–18 h to 2.5 h, composition of only the “Lysis Diluent” solution was modified. Nucleic acid probes in the assay were unchanged. Performance of the modified assay (assay in development; not commercially available) was evaluated and compared to the Versant Assay. Dilution series replicates (>950 results) were used to demonstrate that analytical sensitivity, linearity, accuracy, and precision for the shorter modified assay are comparable to the Versant Assay. HIV RNA-positive clinical specimens (n = 135) showed no significant difference in quantification between the modified assay and the Versant Assay. Equivalent relative quantification of samples of eight genotypes was demonstrated for the two assays. Elevated levels of several potentially interfering endogenous substances had no effect on quantification or specificity of the modified assay. The modified assay with drastically improved turnaround time demonstrates the viability of signal-amplifying technology, such as bDNA, as an alternative to the PCR-based assays dominating viral load monitoring in clinical laboratories. Highly sensitive bDNA assays with a single day turnaround may be ideal for laboratories with especially stringent cost, contamination, or reliability requirements. PMID:22479381

  12. When is it time to get married? Or when should the assay user and the assay developer collaborate?

    PubMed Central

    Swan, S H; Lasley, B L

    1991-01-01

    Hormone assays are being developed in the laboratory to detect specific molecular markers in nonclinical populations. Epidemiology is increasingly using these assays to improve the precision with which disease processes and exposures can be defined. This growing body of molecular epidemiology requires a high degree of cooperation between the assay developer and the assay user. We draw on our experience in using a sensitive hormone assay for the detection of early pregnancy via urinary human chorionic gonadotropin to illustrate these points. We conclude that this collaborative effort, in addition to making this study possible, has provided unexpected rewards. PMID:1954925

  13. Comparison of gull-specific assays targeting 16S rRNA gene of Catellicoccus marimammalium and Streptococcus spp.

    EPA Science Inventory

    Gulls have been implicated as a source of fecal contamination in inland and coastal waters. Only one gull-specific assay is currently available (i.e., gull2 qPCR assay). This assay is based on the 16S rRNA gene of Catellicocclls marimammalium and has showed a high level of host-s...

  14. Nano-immunosafety: issues in assay validation

    NASA Astrophysics Data System (ADS)

    Boraschi, Diana; Oostingh, Gertie J.; Casals, Eudald; Italiani, Paola; Nelissen, Inge; Puntes, Victor F.; Duschl, Albert

    2011-07-01

    Assessing the safety of engineered nanomaterials for human health must include a thorough evaluation of their effects on the immune system, which is responsible for defending the integrity of our body from damage and disease. An array of robust and representative assays should be set up and validated, which could be predictive of the effects of nanomaterials on immune responses. In a trans-European collaborative work, in vitro assays have been developed to this end. In vitro tests have been preferred for their suitability to standardisation and easier applicability. Adapting classical assays to testing the immunotoxicological effects of nanoparticulate materials has raised a series of issues that needed to be appropriately addressed in order to ensure reliability of results. Besides the exquisitely immunological problem of selecting representative endpoints predictive of the risk of developing disease, assay results turned out to be significantly biased by artefactual interference of the nanomaterials or contaminating agents with the assay protocol. Having addressed such problems, a series of robust and representative assays have been developed that describe the effects of engineered nanoparticles on professional and non-professional human defence cells. Two of such assays are described here, one based on primary human monocytes and the other employing human lung epithelial cells transfected with a reporter gene.

  15. Data transformation methods for multiplexed assays

    DOEpatents

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  16. Mechanical property, biocorrosion and in vitro biocompatibility evaluations of Mg-Li-(Al)-(RE) alloys for future cardiovascular stent application.

    PubMed

    Zhou, W R; Zheng, Y F; Leeflang, M A; Zhou, J

    2013-11-01

    Mg-Li-based alloys were investigated for future cardiovascular stent application as they possess excellent ductility. However, Mg-Li binary alloys exhibited reduced mechanical strengths due to the presence of lithium. To improve the mechanical strengths of Mg-Li binary alloys, aluminum and rare earth (RE) elements were added to form Mg-Li-Al ternary and Mg-Li-Al-RE quarternary alloys. In the present study, six Mg-Li-(Al)-(RE) alloys were fabricated. Their microstructures, mechanical properties and biocorrosion behavior were evaluated by using optical microscopy, X-ray diffraction, scanning electronic microscopy, tensile tests, immersion tests and electrochemical measurements. Microstructure characterization indicated that grain sizes were moderately refined by the addition of rare earth elements. Tensile testing showed that enhanced mechanical strengths were obtained, while electrochemical and immersion tests showed reduced corrosion resistance caused by intermetallic compounds distributed throughout the magnesium matrix in the rare-earth-containing Mg-Li alloys. Cytotoxicity assays, hemolysis tests as well as platelet adhesion tests were performed to evaluate in vitro biocompatibilities of the Mg-Li-based alloys. The results of cytotoxicity assays clearly showed that the Mg-3.5Li-2Al-2RE, Mg-3.5Li-4Al-2RE and Mg-8.5Li-2Al-2RE alloys suppressed vascular smooth muscle cell proliferation after 5day incubation, while the Mg-3.5Li, Mg-8.5Li and Mg-8.5Li-1Al alloys were proven to be tolerated. In the case of human umbilical vein endothelial cells, the Mg-Li-based alloys showed no significantly reduced cell viabilities except for the Mg-8.5Li-2Al-2RE alloy, with no obvious differences in cell viability between different culture periods. With the exception of Mg-8.5Li-2Al-2RE, all of the other Mg-Li-(Al)-(RE) alloys exhibited acceptable hemolysis ratios, and no sign of thrombogenicity was found. These in vitro experimental results indicate the potential of Mg

  17. Evaluation of multiplex assay platforms for detection of influenza hemagglutinin subtype specific antibody responses.

    PubMed

    Li, Zhu-Nan; Weber, Kimberly M; Limmer, Rebecca A; Horne, Bobbi J; Stevens, James; Schwerzmann, Joy; Wrammert, Jens; McCausland, Megan; Phipps, Andrew J; Hancock, Kathy; Jernigan, Daniel B; Levine, Min; Katz, Jacqueline M; Miller, Joseph D

    2017-05-01

    Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex ® , and ForteBio ® platforms. Assay sensitivity, specificity, and subtype cross-reactivity were evaluated using a panel of well characterized human sera. Compared to the traditional HI, assay sensitivity ranged from 87% to 92% and assay specificity in sera collected from unexposed persons ranged from 65% to 100% across the platforms. High assay specificity (86-100%) for A(H5N1) rHA was achieved for sera from exposed or unexposed to hetorosubtype influenza HAs. In contrast, assay specificity for A(H1N1)pdm09 rHA using sera collected from A/Vietnam/1204/2004 (H5N1) vaccinees in 2008 was low (22-30%) in all platforms. Although cross-reactivity against rHA subtype proteins was observed in each assay platform, the correct subtype specific responses were identified 78%-94% of the time when paired samples were available for analysis. These results show that high throughput and portable multiplex assays that incorporate rHA can be used to identify influenza subtype specific infections. Published by Elsevier B.V.

  18. Low Cost Tuberculosis Vaccine Antigens in Capsules: Expression in Chloroplasts, Bio-Encapsulation, Stability and Functional Evaluation In Vitro

    PubMed Central

    Yang, Xiangdong; Lloyd, Bethany; Daniell, Henry

    2013-01-01

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading fatal infectious diseases. The development of TB vaccines has been recognized as a major public health priority by the World Health Organization. In this study, three candidate antigens, ESAT-6 (6kDa early secretory antigenic target) and Mtb72F (a fusion polyprotein from two TB antigens, Mtb32 and Mtb39) fused with cholera toxin B-subunit (CTB) and LipY (a cell wall protein) were expressed in tobacco and/or lettuce chloroplasts to facilitate bioencapsulation/oral delivery. Site-specific transgene integration into the chloroplast genome was confirmed by Southern blot analysis. In transplastomic leaves, CTB fusion proteins existed in soluble monomeric or multimeric forms of expected sizes and their expression levels varied depending upon the developmental stage and time of leaf harvest, with the highest-level of accumulation in mature leaves harvested at 6PM. The CTB-ESAT6 and CTB-Mtb72F expression levels reached up to 7.5% and 1.2% of total soluble protein respectively in mature tobacco leaves. Transplastomic CTB-ESAT6 lettuce plants accumulated up to 0.75% of total leaf protein. Western blot analysis of lyophilized lettuce leaves stored at room temperature for up to six months showed that the CTB-ESAT6 fusion protein was stable and preserved proper folding, disulfide bonds and assembly into pentamers for prolonged periods. Also, antigen concentration per gram of leaf tissue was increased 22 fold after lyophilization. Hemolysis assay with purified CTB-ESAT6 protein showed partial hemolysis of red blood cells and confirmed functionality of the ESAT-6 antigen. GM1-binding assay demonstrated that the CTB-ESAT6 fusion protein formed pentamers to bind with the GM1-ganglioside receptor. The expression of functional Mycobacterium tuberculosis antigens in transplastomic plants should facilitate development of a cost-effective and orally deliverable TB booster vaccine with potential for long

  19. Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays.

    PubMed

    Hopkins, Mark; Hau, Sarah; Tiernan, Caroline; Papadimitropoulos, Athanasios; Chawla, Anu; Beloukas, Apostolos; Geretti, Anna Maria

    2015-08-01

    Quantitative measurement of HIV-1 RNA levels in plasma ('viral load') plays a central role in clinical management. The choice of assay platform can influence results and treatment decisions. To compare the analytical performance of the new TMA-based Hologic Aptima(®) HIV-1 Quant Dx assay with that of three PCR-based assays: Abbott RealTime HIV-1, Qiagen Artus(®) HI Virus-1 QS-RGQ, and Roche CAP/CTM HIV-1 Test v2. Assay performance was evaluated using Acrometrix HIV-1 RNA Standard panels; the 3rd WHO HIV-1 RNA International Standard (12-500 copies/ml; 6 dilutions; 9 replicates); and plasma samples from 191 HIV-positive patients. Aptima showed high (>0.99) precision, accuracy and concordance with the Acrometrix Standards across a wide dynamic range (2.0-6.7 log10copies/ml). Variance caused up to 2.1 (Aptima), 1.7 (RealTime), 7.5 (Artus), and 1.9 (CAP/CTM) fold changes in the International Standard quantifications at 50-500 copies/ml. HIV-1 RNA detection rates in plasma samples were 141/191 (74%), 119/191 (62%), 108/191 (57%), and 145/191 (76%) for Aptima, RealTime, Artus and CAP/CTM, respectively. For categorising samples either side of 50 copies/ml, Aptima had excellent agreement with RealTime (kappa 0.92; 95% CI 0.87-0.98); lowest agreement was with Artus (kappa 0.79; 95%CI 0.70-0.88). Aptima quantifications were mean 0.12 and 0.06 log10copies/ml higher compared with RealTime and CAP/CTM, respectively, and 0.05 log10copies/ml lower compared with Artus. Limits of agreement were narrowest when comparing Aptima to RealTime. The new Aptima HIV assay is sensitive, precise, and accurate. HIV assays exhibit discordance at low HIV-1 RNA copy numbers. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Cross-reactivity of insulin analogues with three insulin assays.

    PubMed

    Dayaldasani, A; Rodríguez Espinosa, M; Ocón Sánchez, P; Pérez Valero, V

    2015-05-01

    Immunometric assays have recently shown higher specificity in the detection of human insulin than radioimmunoassays with almost no cross-reaction with proinsulin or C peptide. The introduction of the new insulin analogues on the market, however, has raised the need to define their cross-reactivity in these assays. Several studies have been published in this regard with different results. The analogues studied were insulins lispro, aspart, glargine, detemir, and glulisine. Insulin concentrations were measured in Immulite(®) 2000 and Advia Centaur(®) XP (Siemens Healthcare Diagnostics), and Elecsys(®) Modular Analytics E170 (Roche). All samples were processed 15 times in the same analytical run following a random sequence. Those samples which showed statistically and clinically significant changes in insulin concentration were reprocessed using increasing concentrations of analogue, and this was done twice, using two different serum pools, one with a low concentration of insulin and one with a high concentration of insulin. In the Elecsys(®) E170 analyser, glargine showed statistical changes (comparison of mean concentrations with p < 0.05) and clinically significant changes in measured insulin (percentage difference 986.2% > reference change value: 59.8%), and the interference increased with increasing concentrations of analogue; the differences were not significant in the case of the other analogues. In the Advia Centaur(®) and Immulite(®) 2000 only the results for glulisine did not present significance (percentage difference 44.7% < reference change value 103.5%). Increasing concentrations of aspart, glargine, and lispro showed increased interference in Immulite(®) 2000. In the Elecsys(®) E170 assay, relevant cross-reactivity was only detected with insulin glargine, whereas in the other analysers all analogues except glulisine showed significant interference. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  1. Immunoblotting assays for keratan sulfate.

    PubMed

    Yoon, Jung Hae; Brooks, Randolph; Halper, Jaroslava

    2002-07-15

    The detection of microquantities of glycosaminoglycans (GAGs) in biological samples has been hampered by the lack of sensitive methods. In this paper we describe the modification and development of three sensitive assays capable of detecting nanogram quantities of GAGs in biological samples. The first assay detects total GAGs. It is a modified Alcian blue dye precipitation assay in which the dye binds to the negatively charged GAGs in CsCl-fractionated extracts from chicken tendons. This assay compares favorably with the widely used uronic acid assay in terms of its sensitivity and ability to detect all classes of GAGs, including keratan sulfate (KS). Two other assays, dot-blotting and immunoblotting, detect KS in complex mixtures and can be easily adapted for the detection of other GAGs. Both take advantage of binding of carboxyl and sulfate groups of GAGs to trivalent neodymium. In dot-blotting, samples were directly blotted onto nitrocellulose membrane soaked in Nd(2)(SO(4))(3) buffer, and KS was detected with the monoclonal anti-KS 5-D-4 antibody and an avidin-biotin complex detection system. In immunoblotting, the samples were first separated in 28% polyacrylamide gels, transferred onto a Nd(2)(SO(4))(3)-soaked nitrocellulose membrane using a phosphate buffer system, and stained and developed using the same protocol as in dot-blotting. Whereas dot-blotting allows the use of very low quantities of samples because of its high sensitivity (lower detection limit was 5 ng), immunoblotting provides more specificity.

  2. RAS - Screens & Assays - Drug Discovery

    Cancer.gov

    The RAS Drug Discovery group aims to develop assays that will reveal aspects of RAS biology upon which cancer cells depend. Successful assay formats are made available for high-throughput screening programs to yield potentially effective drug compounds.

  3. A fluorescence polarization binding assay to identify inhibitors of flavin-dependent monooxygenases

    PubMed Central

    Qi, Jun; Kizjakina, Karina; Robinson, Reeder; Tolani, Karishma; Sobrado, Pablo

    2014-01-01

    N-hydroxylating monooxygenases (NMOs) are essential for pathogenesis in fungi and mycobacteria. NMOs catalyze the hydroxylation of lysine and ornithine in the biosynthesis of hydroxamate-containing siderophores. Inhibition of kynurenine monooxygenase (KMO), which catalyzes the conversion of l-kynurenine to 3-hydroxykynurenine, alleviates neurodegenerative disorders such as Huntington’s and Alzheimer’s diseases and brain infections caused by the parasite Trypanosoma brucei. These enzymes are examples of flavin-dependent monooxygenases, which are validated drug targets. Here, we describe the development and optimization of a fluorescence polarization assay to identify potential inhibitors of flavin monooxygenases. Fluorescently-labeled ADP molecules were synthesized and tested. An ADP-TAMRA chromophore bound to KMO with a Kd value of 0.60 ± 0.05 μM and to the NMOs from Aspergillus fumigatus and Mycobacterium smegmatis with Kd values of 2.1 ± 0.2 μM and 4.0 ± 0.2 μM, respectively. The assay was tested in competitive binding experiments with substrates and products of KMO and an NMO. Furthermore, we showed that this assay can be used to identify inhibitors of NMOs. A Z’-factor of 0.77 was calculated and we show that the assay exhibits good tolerance to temperature, incubation time, and DMSO concentration. PMID:22410281

  4. A fluorescence polarization binding assay to identify inhibitors of flavin-dependent monooxygenases.

    PubMed

    Qi, Jun; Kizjakina, Karina; Robinson, Reeder; Tolani, Karishma; Sobrado, Pablo

    2012-06-01

    N-Hydroxylating monooxygenases (NMOs) are essential for pathogenesis in fungi and bacteria. NMOs catalyze the hydroxylation of sine and ornithine in the biosynthesis of hydroxamate-containing siderophores. Inhibition of kynurenine monooxygenase (KMO), which catalyzes the conversion of kynurenine to 3-hydroxykynurenine, alleviates neurodegenerative disorders such as Huntington's and Alzheimer's diseases and brain infections caused by the parasite Trypanosoma brucei. These enzymes are examples of flavin-dependent monooxygenases, which are validated drug targets. Here, we describe the development and optimization of a fluorescence polarization assay to identify potential inhibitors of flavin-dependent monooxygenases. Fluorescently labeled ADP molecules were synthesized and tested. An ADP-TAMRA chromophore bound to KMO with a K(d) value of 0.60 ± 0.05 μM and to the NMOs from Aspergillus fumigatus and Mycobacterium smegmatis with K(d) values of 2.1 ± 0.2 and 4.0 ± 0.2 μM, respectively. The assay was tested in competitive binding experiments with substrates and products of KMO and an NMO. Furthermore, we show that this assay can be used to identify inhibitors of NMOs. A Z' factor of 0.77 was calculated, and we show that the assay exhibits good tolerance to temperature, incubation time, and dimethyl sulfoxide concentration. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Development of a noncompetitive phage anti-immunocomplex assay for brominated diphenyl ether 47

    PubMed Central

    Kim, Hee-Joo; Rossotti, Martin A.; Ahn, Ki Chang; González-Sapienza, Gualberto G.; Gee, Shirley J.; Musker, Ruthie; Hammock, Bruce D.

    2010-01-01

    We present a new application of the noncompetitive phage anti-immunocomplex assay (PHAIA) by converting an existing competitive assay to a versatile noncompetitive sandwich-type format using immunocomplex binding phage-borne peptides to detect the brominated flame retardant, brominated diphenyl ether 47 (BDE 47). Three phage-displayed 9-mer disulfide-constrained peptides that recognize the BDE 47–polyclonal antibody immunocomplex were isolated. The resulting PHAIAs showed variable sensitivities, and the most sensitive peptide had a dose–response curve with an SC50 (concentration of analyte producing 50% saturation of the signal) of 0.7 ng/ml BDE 47 and a linear range of 0.3–2 ng/ml, which was nearly identical to the best heterologous competitive format (IC50 of 1.8 ng/ml, linear range of 0.4–8.5/ml). However, the PHAIA was 1400-fold better than homologous competitive assay. The validation of the PHAIA with extracts of house furniture foam as well as human and calf sera spiked with BDE 47 showed overall recovery of 80–113%. The PHAIA was adapted to a dipstick format (limit of detection of 3.0 ng/ml), and a blind test with six random extracts of local house furniture foams showed that the results of the PHAIA and dipstick assay were consistent, giving the same positive and negative detection. PMID:20152791

  6. Analytical and clinical evaluation of the Abbott RealTime hepatitis B sequencing assay.

    PubMed

    Huh, Hee Jae; Kim, Ji-Youn; Lee, Myoung-Keun; Lee, Nam Yong; Kim, Jong-Won; Ki, Chang-Seok

    2016-12-01

    Long-term nucleoside analogue (NA) treatment leads to selection for drug-resistant mutations in patients undergoing hepatitis B virus (HBV) therapy. The Abbott RealTime HBV Sequencing assay (Abbott assay; Abbott Molecular Inc., Des Plaines, IL, USA) targets the reverse transcriptase region of the polymerase gene and as such has the ability to detect NA resistance-associated mutations in HBV. We evaluated the analytical performance of the Abbott assay and compared its diagnostic performance to that of a laboratory-developed nested-PCR and sequencing method. The analytical sensitivity of the Abbott assay was determined using a serially-diluted WHO International Standard. To validate the clinical performances of the Abbott assay and the laboratory-developed assay, 89 clinical plasma samples with various levels of HBV DNA were tested using both assays. The limit of detection of the Abbott assay, was 210IU/ml and it successfully detected mutations when the mutant types were present at levels ≥20%. Among 89 clinical specimens, 43 and 42 were amplification positive in the Abbott and laboratory-developed assays, respectively, with 87.6% overall agreement (78/89; 95% confidence interval [CI], 78.6-93.4). The Abbott assay failed to detect the minor mutant populations in two specimens, and therefore overall concordance was 85.3% (76/89), and the kappa value was 0.79 (95% CI, 0.67-0.90). The Abbott assay showed comparable diagnostic performance to laboratory-developed nested PCR followed by direct sequencing, and may be useful as a routine method for detecting HBV NA resistance-associated mutations in clinical laboratory settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Comparative evaluation of genotoxicity by micronucleus assay in the buccal mucosa over comet assay in peripheral blood in oral precancer and cancer patients.

    PubMed

    Katarkar, Atul; Mukherjee, Sanjit; Khan, Masood H; Ray, Jay G; Chaudhuri, Keya

    2014-09-01

    Early detection and quantification of DNA damage in oral premalignancy or malignancy may help in management of the disease and improve survival rates. The comet assay has been successfully utilised to detect DNA damage in oral premalignant or malignancy. However, due to the invasive nature of collecting blood, it may be painful for many unwilling patients. This study compares the micronucleus (MN) assay in oral buccal mucosa cells with the comet assay in peripheral blood cells in a subset of oral habit-induced precancer and cancer patients. For this, MN assay of exfoliated epithelial cells was compared with comet assay of peripheral blood leucocytes among 260 participants, including those with oral lichen planus (OLP; n = 52), leukoplakia (LPK; n = 51), oral submucous fibrosis (OSF; n = 51), oral squamous cell carcinoma (OSCC; n = 54) and normal volunteers (n = 52). Among the precancer groups, LPK patients showed significantly higher levels of DNA damage as reflected by both comet tail length (P < 0.0001) and micronuclei (MNi) frequency (P = 0.0009). The DNA damage pattern in precancer and cancer patients was OLP < OSF < LPK < OSCC, and with respective oral habits, it was multiple habits > cigarette + khaini > cigarette smokers > areca + khaini > areca. There was no significant difference in the comet length and MNi frequency between males and females who had oral chewing habits. An overall significant correlation was observed between MNi frequency and comet tail length with r = 0.844 and P < 0.0001. Thus, the extent of DNA damage evaluation by the comet assay in peripheral blood cells is perfectly reflected by the MN assay on oral exfoliated epithelial cells, and MNi frequency can be used with the same effectiveness and greater efficiency in early detection of oral premalignant conditions. © The Author 2014. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Anti-oxidative assays as markers for anti-inflammatory activity of flavonoids.

    PubMed

    Chanput, Wasaporn; Krueyos, Narumol; Ritthiruangdej, Pitiporn

    2016-11-01

    The complexity of in vitro anti-inflammatory assays, the cost and time consumed, and the necessary skills can be a hurdle to apply to promising compounds in a high throughput setting. In this study, several antioxidative assays i.e. DPPH, ABTS, ORAC and xanthine oxidase (XO) were used to examine the antioxidative activity of three sub groups of flavonoids: (i) flavonol: quercetin, myricetin, (ii) flavanone: eriodictyol, naringenin (iii) flavone: luteolin, apigenin. A range of flavonoid concentrations was tested for their antioxidative activities and were found to be dose-dependent. However, the flavonoid concentrations over 50ppm were found to be toxic to the THP-1 monocytes. Therefore, 10, 20 and 50ppm of flavonoid concentrations were tested for their anti-inflammatory activity in lipopolysaccharide (LPS)-stimulated THP-1 monocytes. Expression of inflammatory genes, IL-1β, IL-6, IL-8, IL-10 and TNF-α was found to be sequentially decreased when flavonoid concentration increased. Principle component analysis (PCA) was used to investigate the relationship between the data sets of antioxidative assays and the expression of inflammatory genes. The results showed that DPPH, ABTS and ORAC assays have an opposite correlation with the reduction of inflammatory genes. Pearson correlation exhibited a relationship between the ABTS assay and the expression of three out of five analyzed genes; IL-1β, IL-6 and IL-8. Our findings indicate that ABTS assay can potentially be an assay marker for anti-inflammatory activity of flavonoids. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Tolerance assays: measuring the unknown.

    PubMed

    Newell, Kenneth A; Larsen, Christian P

    2006-06-15

    Distinguishing transplant recipients who will benefit from a reduction in, or even the withdrawal of, immunosuppression from those who require intensive, lifelong immunosuppression will be dependent on developing strategies for immune monitoring. Currently, no assays have been shown to accurately predict the development or presence of donor-specific tolerance in humans after transplantation. In this overview we describe and discuss those assays that we believe may be useful for identifying tolerant transplant recipients. Validation of "tolerance" assays will be critical for the safe development of tolerance regimens in humans.

  10. Development of immunoglobulin class-specific enzyme-linked immunosorbent assays for measuring antibodies against avian rotavirus.

    PubMed

    Myers, T J; Schat, K A; Mockett, A P

    1989-01-01

    Immunoglobulin class-specific enzyme-linked immunosorbent assays were developed for detecting antibodies against avian rotavirus in serum, intestinal contents, and bile from experimentally infected specific-pathogen-free (SPF) chickens. Both indirect and antibody-capture (AbC) assays were developed based on monoclonal antibodies specific for chicken IgG, IgM, and IgA. Treatment of purified rotavirus with sodium thiocyanate before coating the plate improved the rotavirus-specific reading in the indirect assay. Use of Immunolon 2 plates facilitated attachment of monoclonal antibodies to the plate in the AbC assay. Addition of 5% powdered skim milk to the diluent buffer reduced nonspecific background readings. The indirect assay was superior for detecting rotavirus-specific IgG, whereas the AbC assay was better for detecting rotavirus-specific IgM and IgA. The presence of intestinal contents in the assay wells did not reduce the measurable titers of IgG, IgM, or IgA. These assays showed that SPF chickens produced systemic and mucosal antibodies against avian rotavirus.

  11. Kefiran antagonizes cytopathic effects of Bacillus cereus extracellular factors.

    PubMed

    Medrano, Micaela; Pérez, Pablo Fernando; Abraham, Analía Graciela

    2008-02-29

    Kefiran, the polysaccharide produced by microorganisms present in kefir grains, is a water-soluble branched glucogalactan containing equal amounts of D-glucose and D-galactose. In this study, the effect of kefiran on the biological activity of Bacillus cereus strain B10502 extracellular factors was assessed by using cultured human enterocytes (Caco-2 cells) and human erythrocytes. In the presence of kefiran concentrations ranging from 300 to 1000 mg/L, the ability of B. cereus B10502 spent culture supernatants to detach and damage cultured human enterocytes was significantly abrogated. In addition, mitochondrial dehydrogenase activity was higher when kefiran was present during the cell toxicity assays. Protection was also demonstrated in hemolysis and apoptosis/necrosis assays. Scanning electron microscopy showed the protective effect of kefiran against structural cell damages produced by factors synthesized by B. cereus strain B10502. Protective effect of kefiran depended on strain of B. cereus. Our findings demonstrate the ability of kefiran to antagonize key events of B. cereus B10502 virulence. This property, although strain-specific, gives new perspectives for the role of bacterial exopolysaccharides in functional foods.

  12. Tungsten carbide-cobalt as a nanoparticulate reference positive control in in vitro genotoxicity assays.

    PubMed

    Moche, Hélène; Chevalier, Dany; Barois, Nicolas; Lorge, Elisabeth; Claude, Nancy; Nesslany, Fabrice

    2014-01-01

    With the increasing human exposure to nanoparticles (NP), the evaluation of their genotoxic potential is of significant importance. However, relevance for NP of the routinely used in vitro genotoxicity assays is often questioned, and a nanoparticulate reference positive control would therefore constitute an important step to a better testing of NP, ensuring that test systems are really appropriate. In this study, we investigated the possibility of using tungsten carbide-cobalt (WC-Co) NP as reference positive control in in vitro genotoxicity assays, including 2 regulatory assays, the mouse lymphoma assay and the micronucleus assay, and in the Comet assay, recommended for the toxicological evaluation of nanomedicines by the French Agency of Human Health Products (Afssaps). Through these assays, we were able to study different genetic endpoints in 2 cell types commonly used in regulatory genotoxicity assays: the L5178Y mouse lymphoma cell line and primary cultures of human lymphocytes. Our results showed that the use of WC-Co NP as positive control in in vitro genotoxicity assays was conceivable, but that different parameters have to be considered, such as cell type and treatment schedule. L5178Y mouse lymphoma cells did not provide satisfactory results in the 3 performed tests. However, human lymphocytes were more sensitive to genotoxic effects induced by WC-Co NP, particularly after a 24-h treatment in the in vitro micronucleus assay and after a 4-h treatment in the in vitro Comet assay. Under such conditions, WC-Co could be used as a nanoparticulate reference positive control in these assays.

  13. Practices for Identifying and Rejecting Hemolyzed Specimens Are Highly Variable in Clinical Laboratories.

    PubMed

    Howanitz, Peter J; Lehman, Christopher M; Jones, Bruce A; Meier, Frederick A; Horowitz, Gary L

    2015-08-01

    Hemolysis is an important clinical laboratory quality attribute that influences result reliability. To determine hemolysis identification and rejection practices occurring in clinical laboratories. We used the College of American Pathologists Survey program to distribute a Q-Probes-type questionnaire about hemolysis practices to Chemistry Survey participants. Of 3495 participants sent the questionnaire, 846 (24%) responded. In 71% of 772 laboratories, the hemolysis rate was less than 3.0%, whereas in 5%, it was 6.0% or greater. A visual scale, an instrument scale, and combination of visual and instrument scales were used to identify hemolysis in 48%, 11%, and 41% of laboratories, respectively. A picture of the hemolysis level was used as an aid to technologists' visual interpretation of hemolysis levels in 40% of laboratories. In 7.0% of laboratories, all hemolyzed specimens were rejected; in 4% of laboratories, no hemolyzed specimens were rejected; and in 88% of laboratories, some specimens were rejected depending on hemolysis levels. Participants used 69 different terms to describe hemolysis scales, with 21 terms used in more than 10 laboratories. Slight and moderate were the terms used most commonly. Of 16 different cutoffs used to reject hemolyzed specimens, moderate was the most common, occurring in 30% of laboratories. For whole blood electrolyte measurements performed in 86 laboratories, 57% did not evaluate the presence of hemolysis, but for those that did, the most common practice in 21 laboratories (24%) was centrifuging and visually determining the presence of hemolysis in all specimens. Hemolysis practices vary widely. Standard assessment and consistent reporting are the first steps in reducing interlaboratory variability among results.

  14. Betrixaban: Impact on Routine and Specific Coagulation Assays-A Practical Laboratory Guide.

    PubMed

    Siriez, Romain; Evrard, Jonathan; Dogné, Jean-Michel; Pochet, Lionel; Gheldof, Damien; Chatelain, Bernard; Mullier, François; Douxfils, Jonathan

    2018-06-11

     Betrixaban is a novel direct oral factor Xa inhibitor approved by the Food and Drug Administration for prophylaxis of venous thromboembolism in adult patients hospitalized for an acute illness at risk for thromboembolic complications. Assessment of the anti-coagulant effect of betrixaban may be useful in some situations. Also, clinicians need to know how routine coagulation assays are influenced.  The aim of this study is to determine which coagulation assay(s) should be used to assess the impact of betrixaban on haemostasis and provide laboratory guidance for their interpretation.  Betrixaban was spiked at final concentrations ranging from 0 to 250 ng/mL in platelet-poor plasma. Different reagents from several manufacturers were tested and the impact of betrixaban on pro-thrombin time (PT), activated partial thromboplastin time (aPTT), dilute Russel viper venom time (dRVV-T), chromogenic anti-Xa assays, thrombin generation assay (TGA), and a large panel of haemostasis diagnostic tests has been assessed.  A concentration-dependent prolongation of aPTT, PT and dRVV-T is observed. The sensitivity mainly depends on the reagent. Chromogenic anti-Xa assays show high sensitivity depending on the reagent and/or the methodology. These assays applicable for other direct factor Xa inhibitors have to be adapted to obtain a relevant range of measurement. TGA may also be attractive to assess the anti-coagulant activity of betrixaban.  Adapted chromogenic anti-Xa assays are the most appropriate assays to estimate the concentration of betrixaban. Betrixaban significantly affects several haemostasis diagnostic tests and this needs to be taken into consideration when requesting and interpreting such tests. Schattauer GmbH Stuttgart.

  15. Comparison of the Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay with the original standard assay and cell culture.

    PubMed

    Chan, E L; Brandt, K; Stoneham, H; Horsman, G

    1997-08-01

    The new Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay was evaluated by comparison with the original standard assay and cell culture. A total of 853 paired male and female genital tract specimens was tested with both Sanofi Chlamydia Microplate EIA shortened and standard assays and the results were compared with those of cell culture. For confirmation, a blocking assay run in the shortened format was used. Discrepancies between the three methods were resolved by a direct fluorescent antibody (DFA) test on the EIA samples or the culture retentate, or both. After resolution of discrepant results, the standard assay had a sensitivity, specificity, positive predictive value and negative predictive value of 98.5%, 100%, 100% and 99.9%, respectively. The shortened assay results were 100%, 100%, 100% and 100%, respectively. The shortened assay takes approximately 1.5 h less time than the standard assay and this study demonstrated that they have equivalent sensitivity and specificity. The improvement in turnaround time enables results to be reported on the same day.

  16. Against the proposition: for the diagnosis of viral infections, commercial assays provide more reliable results than do in-house assays.

    PubMed

    James, Vivienne

    2008-01-01

    There are no differences inherent in the design of commercial or in-house assays and their early development is similar. The same principles apply and it is on the same criteria of accuracy, reproducibility and clinical relevance of results that all assays are judged. However, if there is sufficient uptake of a commercial assay, its strengths and any flaws soon become apparent and it will only be the best commercial assays that remain in the market. For the in-house assays it is through comparability studies and external quality assessment (EQA) schemes that the best can be demonstrated, albeit this information is only accessible initially to the EQA provider and the laboratories using the assays. The EQA results described here support my supposition that, for the diagnosis of viral infections, commercial assays do not provide more reliable results than do in-house assays.

  17. Improved Dual-Luciferase Reporter Assays for Nuclear Receptors

    PubMed Central

    Paguio, Aileen; Stecha, Pete; Wood, Keith V; Fan, Frank

    2010-01-01

    Nuclear receptors play important roles in many cellular functions through control of gene transcription. It is also a large target class for drug discovery. Luciferase reporter assays are frequently used to study nuclear receptor function because of their wide dynamic range, low endogenous activity, and ease of use. Recent improvements of luciferase genes and vectors have further enhanced their utilities. Here we applied these improvements to two reporter formats for studying nuclear receptors. The first assay contains a Murine Mammary Tumor Virus promoter upstream of a destabilized luciferase. The presence of response elements for nuclear hormone receptor in this promoter allows the studies of endogenous and/or exogenous full length receptors. The second assay contains a ligand binding domain (LBD) of a nuclear receptor fused to the GAL4 DNA binding domain (DBD) on one vector and multiple Gal4 Upstream Activator Sequences (UAS) upstream of luciferase reporter on another vector. We showed that codon optimization of luciferase reporter genes increased expression levels in conjunction with the incorporation of protein destabilizing sequences into luciferase led to a larger assay dynamic range in both formats. The optimum number of UAS to generate the best response was determined. The expression vector for nuclear receptor LBD/GAL4 DBD fusion also constitutively expresses a Renilla luciferase-neoR fusion protein, which provides selection capability (G418 resistance, neoR) as well as an internal control (Renilla luciferase). This dual-luciferase format allowed detecting compound cytotoxicity or off-target change in expression during drug screening, therefore improved data quality. These luciferase reporter assays provided better research and drug discovery tools for studying the functions of full length nuclear receptors and ligand binding domains. PMID:21687560

  18. Abbott ARCHITECT iPhenytoin assay versus similar assays for measuring free phenytoin concentrations.

    PubMed

    Tacker, Danyel Hermes; Robinson, Randy; Perrotta, Peter L

    2014-01-01

    To measure free phenytoin (FP) concentrations in filtered specimens using the Abbott ARCHITECT iPhenytoin assay and to compare results from this method with results from the Abbott TDx/FLx assays. We verified accuracy, analytic measurement range, and precision for FP measurements. For correlation and therapeutic interval studies, we used filtered calibrators, controls, proficiency-testing materials, and surplus clinical samples. After implementation, we determined proficiency testing results. The analytic measurement range was 2.0 to 25.0 micromol/L. Quality control materials (6.1, 12.6, and 20.1 micromol/L) provided mean (SD) recoveries of 96.1 (5.0%), 99.2 (5.0%), and 99.3 (5.7%), respectively, and coefficients of variation of 5.2%, 5.0%, and 5.8%, respectively. Clinical specimens produced mean (SD) FP recovery levels of 103.7 (10.6%) (bias, 0.1 [0.3] micromol/L). Altering the FP therapeutic range (4.0-8.0 micromol/L) was unnecessary. Proficiency testing yielded consistently acceptable results. Our accuracy, precision, and correlation results were similar for the TDx/FLx and ARCHITECT assays, which demonstrates that the ARCHITECT iPhenytoin assay is acceptable for clinical FP measurements.

  19. Photohemolytic potency of tetracyclines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjellerup, M.; Ljunggren, B.

    1985-04-01

    Hemolysis induced by long-wave ultraviolet radiation (UVA) and 8 different commercial tetracycline derivatives was studied in a model using human red blood cells. Demethylchlortetracycline and doxycycline were shown to have pronounced hemolytic properties causing 88% and 85% hemolysis, respectively, at a concentration of 50 micrograms/ml and 72 J/ cm2 of UVA. Tetracycline, oxytetracycline, and chlortetracycline caused maximally 18% hemolysis at 200 micrograms/ml and lymecycline only 7% at 100 micrograms/ml. Methacycline showed intermediate hemolytic effect of 36% at 200 micrograms/ml. Minocycline had no hemolytic effect whatsoever. These experimental data correlate very well with clinical reports and comparative phototoxicity trials in humans.more » Photohemolysis may thus be of value for predicting tetracycline phototoxicity.« less

  20. Development of a lion-specific interferon-gamma assay.

    PubMed

    Maas, M; van Kooten, P J S; Schreuder, J; Morar, D; Tijhaar, E; Michel, A L; Rutten, V P M G

    2012-10-15

    The ongoing spread of bovine tuberculosis (BTB) in African free-ranging lion populations, for example in the Kruger National Park, raises the need for diagnostic assays for BTB in lions. These, in addition, would be highly relevant for zoological gardens worldwide that want to determine the BTB status of their lions, e.g. for translocations. The present study concerns the development of a lion-specific IFN-γ assay, following the production and characterization of monoclonal antibodies specific for lion interferon-gamma (IFN-γ). Recombinant lion IFN-γ (rLIFN-γ) was produced in mammalian cells and used to immunize mice to establish hybridoma cell lines producing monoclonal antibodies. These were used to develop a sensitive, lion IFN-γ-specific capture ELISA, able to detect rLIFN-γ to the level of 160 pg/ml. Recognition of native lion IFN-γ was shown in an initial assessment of supernatants of mitogen stimulated whole blood cultures of 11 known BTB-negative lions. In conclusion, the capture ELISA shows potential as a diagnostic assay for bovine tuberculosis in lions. Preliminary results also indicate the possible use of the test for other (feline) species. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A novel pyrogallol red-based assay to assess catalase activity: Optimization by response surface methodology.

    PubMed

    Abderrahim, Mohamed; Arribas, Silvia M; Condezo-Hoyos, Luis

    2017-05-01

    Pyrogallol red (PGR) was identified as a novel optical probe for the detection of hydrogen peroxide (H 2 O 2 ) based on horseradish peroxidase (HRP)-catalyzed oxidation. Response surface methodology (RSM) was applied as a tool to optimize the concentrations of PGR (100µmolL -1 ), HRP (1UmL -1 ) and H 2 O 2 (250µmolL -1 ) and used to develop a sensitive PGR-based catalase (CAT) activity assay (PGR-CAT assay). N-ethylmaleimide -NEM- (102mmolL -1 ) was used to avoid interference produced by thiol groups while protecting CAT activity. Incubation time (30min) for samples or CAT used as standard and H 2 O 2 as well as signal stability (stable between 5 and 60min) were also evaluated. PGR-CAT assay was linear within the range of 0-4UmL -1 (R 2 =0.993) and very sensitive with limits of detection (LOD) of 0.005UmL -1 and quantitation (LOQ) of 0.01UmL -1 . PGR-CAT assay showed an adequate intra-day RSD=0.6-9.5% and inter-day RSD=2.4-8.9%. Bland-Altman analysis and Passing-Bablok and Pearson correlation analysis showed good agreement between CAT activity as measured by the PRG-CAT assay and the Amplex Red assay. The PGR-CAT assay is more sensitive than all the other colorimetric assays reported, particularly the Amplex Red assay, and the cost of PGR is a small fraction (about 1/1000) of that of an Amplex Red probe, so it can be expected to find wide use among scientists studying CAT activity in biological samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Evaluation of environmental genotoxicity by comet assay in Columba livia.

    PubMed

    González-Acevedo, Anahi; García-Salas, Juan A; Gosálvez, Jaime; Fernández, José Luis; Dávila-Rodríguez, Martha I; Cerda-Flores, Ricardo M; Méndez-López, Luis F; Cortés-Gutiérrez, Elva I

    2016-01-01

    The concentrations of recognized or suspected genotoxic and carcinogenic agents found in the air of large cities and, in particular, developing countries, have raised concerns about the potential for chronic health effects in the populations exposed to them. The biomonitoring of environmental genotoxicity requires the selection of representative organisms as "sentinels," as well as the development of suitable and sensitive assays, such as those aimed at assessing DNA damage. The aim of this study was to evaluate DNA damage levels in erythrocytes from Columba livia living in the metropolitan area of Monterrey, Mexico, compared with control animals via comet assay, and to confirm the results via Micronuclei test (MN) and DNA breakage detection-fluorescence in situ hybridization (DBD-FISH). Our results showed a significant increase in DNA migration in animals from the area assayed compared with that observed in control animals sampled in non-contaminated areas. These results were confirmed by MN test and DBD-FISH. In conclusion, these observations confirm that the examination of erythrocytes from Columba livia via alkaline comet assay provides a sensitive and reliable end point for the detection of environmental genotoxicants.

  3. OpenComet: An automated tool for comet assay image analysis

    PubMed Central

    Gyori, Benjamin M.; Venkatachalam, Gireedhar; Thiagarajan, P.S.; Hsu, David; Clement, Marie-Veronique

    2014-01-01

    Reactive species such as free radicals are constantly generated in vivo and DNA is the most important target of oxidative stress. Oxidative DNA damage is used as a predictive biomarker to monitor the risk of development of many diseases. The comet assay is widely used for measuring oxidative DNA damage at a single cell level. The analysis of comet assay output images, however, poses considerable challenges. Commercial software is costly and restrictive, while free software generally requires laborious manual tagging of cells. This paper presents OpenComet, an open-source software tool providing automated analysis of comet assay images. It uses a novel and robust method for finding comets based on geometric shape attributes and segmenting the comet heads through image intensity profile analysis. Due to automation, OpenComet is more accurate, less prone to human bias, and faster than manual analysis. A live analysis functionality also allows users to analyze images captured directly from a microscope. We have validated OpenComet on both alkaline and neutral comet assay images as well as sample images from existing software packages. Our results show that OpenComet achieves high accuracy with significantly reduced analysis time. PMID:24624335

  4. OpenComet: an automated tool for comet assay image analysis.

    PubMed

    Gyori, Benjamin M; Venkatachalam, Gireedhar; Thiagarajan, P S; Hsu, David; Clement, Marie-Veronique

    2014-01-01

    Reactive species such as free radicals are constantly generated in vivo and DNA is the most important target of oxidative stress. Oxidative DNA damage is used as a predictive biomarker to monitor the risk of development of many diseases. The comet assay is widely used for measuring oxidative DNA damage at a single cell level. The analysis of comet assay output images, however, poses considerable challenges. Commercial software is costly and restrictive, while free software generally requires laborious manual tagging of cells. This paper presents OpenComet, an open-source software tool providing automated analysis of comet assay images. It uses a novel and robust method for finding comets based on geometric shape attributes and segmenting the comet heads through image intensity profile analysis. Due to automation, OpenComet is more accurate, less prone to human bias, and faster than manual analysis. A live analysis functionality also allows users to analyze images captured directly from a microscope. We have validated OpenComet on both alkaline and neutral comet assay images as well as sample images from existing software packages. Our results show that OpenComet achieves high accuracy with significantly reduced analysis time.

  5. Assessment of genotoxic effects of flumorph by the comet assay in mice organs.

    PubMed

    Zhang, T; Zhao, Q; Zhang, Y; Ning, J

    2014-03-01

    The present study investigated the genotoxic effects of flumorph in various organs (brain, liver, spleen, kidney and sperm) of mice. The DNA damage, measured as comet tail length (µm), was determined using the alkaline comet assay. The comet assay is a sensitive assay for the detection of genotoxicity caused by flumorph using mice as a model. Statistically significant increases in comet assay for both dose-dependent and duration-dependent DNA damage were observed in all the organs assessed. The organs exhibited the maximum DNA damage in 96 h at 54 mg/kg body weight. Brain showed maximum DNA damage followed by spleen > kidney > liver > sperm. Our data demonstrated that flumorph had induced systemic genotoxicity in mammals as it caused DNA damage in all tested vital organs, especially in brain and spleen.

  6. Pharmacological profiling of the TRPV3 channel in recombinant and native assays.

    PubMed

    Grubisha, Olivera; Mogg, Adrian J; Sorge, Jessica L; Ball, Laura-Jayne; Sanger, Helen; Ruble, Cara L A; Folly, Elizabeth A; Ursu, Daniel; Broad, Lisa M

    2014-05-01

    Transient receptor potential vanilloid subtype 3 (TRPV3) is implicated in nociception and certain skin conditions. As such, it is an attractive target for pharmaceutical research. Understanding of endogenous TRPV3 function and pharmacology remains elusive as selective compounds and native preparations utilizing higher throughput methodologies are lacking. In this study, we developed medium-throughput recombinant and native cellular assays to assess the detailed pharmacological profile of human, rat and mouse TRPV3 channels. Medium-throughput cellular assays were developed using a Ca(2+) -sensitive dye and a fluorescent imaging plate reader. Human and rat TRPV3 pharmacology was examined in recombinant cell lines, while the mouse 308 keratinocyte cell line was used to assess endogenous TRPV3 activity. A recombinant rat TRPV3 cellular assay was successfully developed after solving a discrepancy in the published rat TRPV3 protein sequence. A medium-throughput, native, mouse TRPV3 keratinocyte assay was also developed and confirmed using genetic approaches. Whereas the recombinant human and rat TRPV3 assays exhibited similar agonist and antagonist profiles, the native mouse assay showed important differences, namely, TRPV3 activity was detected only in the presence of potentiator or during agonist synergy. Furthermore, the native assay was more sensitive to block by some antagonists. Our findings demonstrate similarities but also notable differences in TRPV3 pharmacology between recombinant and native systems. These findings offer insights into TRPV3 function and these assays should aid further research towards developing TRPV3 therapies. © 2013 The British Pharmacological Society.

  7. Simultaneous Multiple MS Binding Assays Addressing D1 and D2 Dopamine Receptors.

    PubMed

    Schuller, Marion; Höfner, Georg; Wanner, Klaus T

    2017-10-09

    MS Binding Assays are a label-free alternative to radioligand binding assays. They provide basically the same capabilities as the latter, but use a non-labeled reporter ligand instead of a radioligand. In contrast to radioligand binding assays, MS Binding Assays offer-owing to the selectivity of mass spectrometric detection-the opportunity to monitor the binding of different reporter ligands at different targets simultaneously. The present study shows a proof of concept for this strategy as exemplified for MS Binding Assays selectively addressing D 1 and D 2 dopamine receptors in a single binding experiment. A highly sensitive, rapid and robust LC-ESI-MS/MS quantification method capable of quantifying both SCH23390 and raclopride, selectively addressing D 1 and D 2 receptors, respectively, was established and validated for this purpose. Based thereon, simultaneous saturation and competition experiments with SCH23390 and raclopride in the presence of both D 1 and D 2 receptors were performed and analyzed by LC-MS/MS within a single chromatographic cycle. The present study thus demonstrates the feasibility of this strategy and the high versatility of MS Binding Assays that appears to surpass that common for conventional radioligand binding assays. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Novel drug and soluble target tolerant antidrug antibody assay for therapeutic antibodies bearing the P329G mutation.

    PubMed

    Wessels, Uwe; Schick, Eginhard; Ritter, Mirko; Kowalewsky, Frank; Heinrich, Julia; Stubenrauch, Kay

    2017-06-01

    Bridging immunoassays for detection of antidrug antibodies (ADAs) are typically susceptible to high concentrations of residual drug. Sensitive drug-tolerant assays are, therefore, needed. An immune complex assay to detect ADAs against therapeutic antibodies bearing Pro329Gly mutation was established. The assay uses antibodies specific for the Pro329Gly mutation for capture and human soluble Fcγ receptor for detection. When compared with a bridging assay, the new assay showed similar precision, high sensitivity to IgG1 ADA and dramatically improved drug tolerance. However, it was not able to detect early (IgM-based) immune responses. Applied in combination with a bridging assay, the novel assay serves as orthogonal assay for immunogenicity assessment and allows further characterization of ADA responses.

  9. Analytical validation of a flow cytometric protocol for quantification of platelet microparticles in dogs.

    PubMed

    Cremer, Signe E; Krogh, Anne K H; Hedström, Matilda E K; Christiansen, Liselotte B; Tarnow, Inge; Kristensen, Annemarie T

    2018-06-01

    Platelet microparticles (PMPs) are subcellular procoagulant vesicles released upon platelet activation. In people with clinical diseases, alterations in PMP concentrations have been extensively investigated, but few canine studies exist. This study aims to validate a canine flow cytometric protocol for PMP quantification and to assess the influence of calcium on PMP concentrations. Microparticles (MP) were quantified in citrated whole blood (WB) and platelet-poor plasma (PPP) using flow cytometry. Anti-CD61 antibody and Annexin V (AnV) were used to detect platelets and phosphatidylserine, respectively. In 13 healthy dogs, CD61 + /AnV - concentrations were analyzed with/without a calcium buffer. CD61 + /AnV - , CD61 + /AnV + , and CD61 - /AnV + MP quantification were validated in 10 healthy dogs. The coefficient of variation (CV) for duplicate (intra-assay) and parallel (inter-assay) analyses and detection limits (DLs) were calculated. CD61 + /AnV - concentrations were higher in calcium buffer; 841,800 MP/μL (526,000-1,666,200) vs without; 474,200 MP/μL (278,800-997,500), P < .05. In WB, PMP were above DLs and demonstrated acceptable (<20%) intra-assay and inter-assay CVs in 9/10 dogs: 1.7% (0.5-8.9) and 9.0% (0.9-11.9), respectively, for CD61 + /AnV - and 2.4% (0.2-8.7) and 7.8% (0.0-12.8), respectively, for CD61 + /AnV + . Acceptable CVs were not seen for the CD61 - /AnV + MP. In PPP, quantifications were challenged by high inter-assay CV, overlapping DLs and hemolysis and lipemia interfered with quantification in 5/10 dogs. Calcium induced higher in vitro PMP concentrations, likely due to platelet activation. PMP concentrations were reliably quantified in WB, indicating the potential for clinical applications. PPP analyses were unreliable due to high inter-CV and DL overlap, and not obtainable due to hemolysis and lipemia interference. © 2018 American Society for Veterinary Clinical Pathology.

  10. The additive properties of Oxygen Radical Absorbance Capacity (ORAC) assay: the case of essential oils.

    PubMed

    Bentayeb, Karim; Vera, Paula; Rubio, Carlos; Nerín, Cristina

    2014-04-01

    The ORAC assay is applied to measure the antioxidant capacity of foods or dietary supplements. Sometimes, the manufacturers claim antioxidant capacities that may not correspond to the constituents of the product. These statements are sheltered by the general understanding that antioxidants might exhibit synergistic properties, but this is not necessarily true when dealing with ORAC assay values. This contribution applies the ORAC assay to measure the antioxidant capacity of ten essential oils typically added to foodstuffs: citronella, dill, basil, red thyme, thyme, rosemary, oregano, clove and cinnamon. The major components of these essential oils were twenty-one chemicals in total. After a preliminary discrimination, the antioxidant capacity of eugenol, carvacrol, thymol, α-pinene, limonene and linalool was determined. The results showed that 72-115% of the antioxidant capacity of the essential oils corresponded to the addition of the antioxidant capacity of their constituents. Thus, the ORAC assay showed additive properties. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. The next three decades of the comet assay: a report of the 11th International Comet Assay Workshop.

    PubMed

    Koppen, Gudrun; Azqueta, Amaya; Pourrut, Bertrand; Brunborg, Gunnar; Collins, Andrew R; Langie, Sabine A S

    2017-05-01

    The International Comet Assay Workshops are a series of scientific conferences dealing with practical and theoretical aspects of the Comet Assay (single-cell gel electrophoresis)-a simple method for detecting DNA strand breaks. The first paper describing such an assay was published over 30 years ago in 1984 by Swedish researchers O. Ostling and K. J. Johanson. Appropriately, the theme for the 2015 meeting was looking to the future: 'The Next 3 Decades of the Comet Assay'. The programme included 25 oral and 43 poster presentations depicting the latest advances in technical developments as well as applications of the comet assay in genotoxicity testing (in vitro and in vivo) and biomonitoring of both humans and the environment. Open discussion sessions based on questions from the participants allowed exchange of practical details on current comet assay protocols. This report summarises technical issues of high importance which were discussed during the sessions. We provide information on ways to improve the assay performance, by testing for cytotoxicity, by using reference samples to reduce or allow for inter-experimental variation, and by standardising quantification of the damage, including replicates and scoring enough comets to ensure statistical validity. After 30 years of experimentation with the comet assay, we are in a position to control the important experimental parameters and make the comet assay a truly reliable method with a wealth of possible applications. © The Author 2017. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Proteomics: from hypothesis to quantitative assay on a single platform. Guidelines for developing MRM assays using ion trap mass spectrometers.

    PubMed

    Han, Bomie; Higgs, Richard E

    2008-09-01

    High-throughput HPLC-mass spectrometry (HPLC-MS) is routinely used to profile biological samples for potential protein markers of disease, drug efficacy and toxicity. The discovery technology has advanced to the point where translating hypotheses from proteomic profiling studies into clinical use is the bottleneck to realizing the full potential of these approaches. The first step in this translation is the development and analytical validation of a higher throughput assay with improved sensitivity and selectivity relative to typical profiling assays. Multiple reaction monitoring (MRM) assays are an attractive approach for this stage of biomarker development given their improved sensitivity and specificity, the speed at which the assays can be developed and the quantitative nature of the assay. While the profiling assays are performed with ion trap mass spectrometers, MRM assays are traditionally developed in quadrupole-based mass spectrometers. Development of MRM assays from the same instrument used in the profiling analysis enables a seamless and rapid transition from hypothesis generation to validation. This report provides guidelines for rapidly developing an MRM assay using the same mass spectrometry platform used for profiling experiments (typically ion traps) and reviews methodological and analytical validation considerations. The analytical validation guidelines presented are drawn from existing practices on immunological assays and are applicable to any mass spectrometry platform technology.

  13. A highly sensitive and selective diagnostic assay based on virus nanoparticles

    NASA Astrophysics Data System (ADS)

    Park, Jin-Seung; Cho, Moon Kyu; Lee, Eun Jung; Ahn, Keum-Young; Lee, Kyung Eun; Jung, Jae Hun; Cho, Yunjung; Han, Sung-Sik; Kim, Young Keun; Lee, Jeewon

    2009-04-01

    Early detection of the protein marker troponin I in patients with a higher risk of acute myocardial infarction can reduce the risk of death from heart attacks. Most troponin assays are currently based on the conventional enzyme linked immunosorbent assay and have detection limits in the nano- and picomolar range. Here, we show that by combining viral nanoparticles, which are engineered to have dual affinity for troponin antibodies and nickel, with three-dimensional nanostructures including nickel nanohairs, we can detect troponin levels in human serum samples that are six to seven orders of magnitude lower than those detectable using conventional enzyme linked immunosorbent assays. The viral nanoparticle helps to orient the antibodies for maximum capture of the troponin markers. High densities of antibodies on the surfaces of the nanoparticles and nanohairs lead to greater binding of the troponin markers, which significantly enhances detection sensitivities. The nickel nanohairs are re-useable and can reproducibly differentiate healthy serum from unhealthy ones. We expect other viral nanoparticles to form similar highly sensitive diagnostic assays for a variety of other protein markers.

  14. Doped colorimetric assay liposomes

    DOEpatents

    Charych, Deborah; Stevens, Raymond C.

    2001-01-01

    The present invention provides compositions comprising colorimetric assay liposomes. The present invention also provides methods for producing colorimetric liposomes and calorimetric liposome assay systems. In preferred embodiments, these calorimetric liposome systems provide high levels of sensitivity through the use of dopant molecules. As these dopants allow the controlled destabilization of the liposome structure, upon exposure of the doped liposomes to analyte(s) of interest, the indicator color change is facilitated and more easily recognized.

  15. Development of a thyroperoxidase inhibition assay for high ...

    EPA Pesticide Factsheets

    High-throughput screening (HTPS) assays to detect inhibitors of thyroperoxidase (TPO), the enzymatic catalyst for thyroid hormone (TH) synthesis, are not currently available. Herein we describe the development of a HTPS TPO inhibition assay. Rat thyroid microsomes and a fluorescent peroxidase substrate, Amplex UltraRed (AUR, LifeTechnologies), were employed in an endpoint assay for comparison to the existing kinetic guaiacol (GUA) oxidation assay. Following optimization of assay metrics including Z’, dynamic range, and activity using methimazole (MMI), the assay was tested with a 21-chemical training set. The potency of MMI-induced TPO inhibition was greater with AUR compared to GUA. The dynamic range and Z’ score with MMI were as follows: 127-fold and 0.62 for the GUA assay, 18-fold and 0.86 for the 96-well AUR assay, and 11.5-fold and 0.93 for the 384-well AUR assay. The 384-well AUR assay drastically reduced animal use, requiring one-tenth of the rat thyroid microsomal protein needed for the GUA 96-well format assay. Fourteen chemicals inhibited TPO, with a relative potency ranking of MMI > ethylene thiourea > 6-propylthiouracil > 2,2’,4,4’-tetrahydroxy-benzophenone > 2-mercaptobenzothiazole > 3-amino-1,2,4-triazole > genistein > 4-propoxyphenol > sulfamethazine > daidzein > 4-nonylphenol > triclosan > iopanoic acid > resorcinol. These data demonstrate the capacity of this assay to detect diverse TPO inhibitors. Seven chemicals acted as negati

  16. A quantitative comet infection assay for influenza virus

    PubMed Central

    Lindsay, Stephen M.; Timm, Andrea; Yin, John

    2011-01-01

    Summary The virus comet assay is a cell-based virulence assay used to evaluate an antiviral drug or antibody against a target virus. The comet assay differs from the plaque assay in allowing spontaneous flows in 6-well plates to spread virus. When implemented quantitatively the comet assay has been shown to have an order-of-magnitude greater sensitivity to antivirals than the plaque assay. In this study, a quantitative comet assay for influenza virus is demonstrated, and is shown to have a 13-fold increase in sensitivity to ribavirin. AX4 cells (MDCK cells with increased surface concentration of α2–6 sialic acid, the influenza virus receptor) have reduced the comet size variability relative to MDCK cells, making them a better host cell for use in this assay. Because of enhanced antiviral sensitivity in flow-based assays, less drug is required, which could lead to lower reagent costs, reduced cytotoxicity, and fewer false-negative drug screen results. The comet assay also serves as a readout of flow conditions in the well. Observations from comets formed at varying humidity levels indicate a role for evaporation in the mechanism of spontaneous fluid flow in wells. PMID:22155578

  17. Single cell kinase signaling assay using pinched flow coupled droplet microfluidics.

    PubMed

    Ramji, Ramesh; Wang, Ming; Bhagat, Ali Asgar S; Tan Shao Weng, Daniel; Thakor, Nitish V; Teck Lim, Chwee; Chen, Chia-Hung

    2014-05-01

    Droplet-based microfluidics has shown potential in high throughput single cell assays by encapsulating individual cells in water-in-oil emulsions. Ordering cells in a micro-channel is necessary to encapsulate individual cells into droplets further enhancing the assay efficiency. This is typically limited due to the difficulty of preparing high-density cell solutions and maintaining them without cell aggregation in long channels (>5 cm). In this study, we developed a short pinched flow channel (5 mm) to separate cell aggregates and to form a uniform cell distribution in a droplet-generating platform that encapsulated single cells with >55% encapsulation efficiency beating Poisson encapsulation statistics. Using this platform and commercially available Sox substrates (8-hydroxy-5-(N,N-dimethylsulfonamido)-2-methylquinoline), we have demonstrated a high throughput dynamic single cell signaling assay to measure the activity of receptor tyrosine kinases (RTKs) in lung cancer cells triggered by cell surface ligand binding. The phosphorylation of the substrates resulted in fluorescent emission, showing a sigmoidal increase over a 12 h period. The result exhibited a heterogeneous signaling rate in individual cells and showed various levels of drug resistance when treated with the tyrosine kinase inhibitor, gefitinib.

  18. Flow cytometric HyPer-based assay for hydrogen peroxide.

    PubMed

    Lyublinskaya, O G; Antonov, S A; Gorokhovtsev, S G; Pugovkina, N A; Kornienko, Ju S; Ivanova, Ju S; Shatrova, A N; Aksenov, N D; Zenin, V V; Nikolsky, N N

    2018-05-30

    HyPer is a genetically encoded fluorogenic sensor for hydrogen peroxide which is generally used for the ratiometric imaging of H 2 O 2 fluxes in living cells. Here, we demonstrate the advantages of HyPer-based ratiometric flow cytometry assay for H 2 O 2 , by using K562 and human mesenchymal stem cell lines expressing HyPer. We show that flow cytometry analysis is suitable to detect HyPer response to submicromolar concentrations of extracellularly added H 2 O 2 that is much lower than concentrations addressed previously in the other HyPer-based assays (such as cell imaging or fluorimetry). Suggested technique is also much more sensitive to hydrogen peroxide than the widespread flow cytometry assay exploiting H 2 O 2 -reactive dye H 2 DCFDA and, contrary to the H 2 DCFDA-based assay, can be employed for the kinetic studies of H 2 O 2 utilization by cells, including measurements of the rate constants of H 2 O 2 removal. In addition, flow cytometry multi-parameter ratiometric measurements enable rapid and high-throughput detection of endogenously generated H 2 O 2 in different subpopulations of HyPer-expressing cells. To sum up, HyPer can be used in multi-parameter flow cytometry studies as a highly sensitive indicator of intracellular H 2 O 2 . Copyright © 2018. Published by Elsevier Inc.

  19. [Quantitative fluorogenic real-time PCR assay for respiratory syncytial virus detection].

    PubMed

    Zhang, Qi-wei; You, Shang-you; Sun, Ji-min; Wu, Qi; Yu, Chun-hua; Zhang, Chu-yu

    2005-07-01

    To Establish a rapid and objective quantitative fluorogenic real-time PCR assay for early detection of human respiratory syncytial virus (hRSV). Two pairs of primers and one TaqMan Fluorogenic probe that are specific for the recognition of the most conservative N gene of hRSV for virus detection with LighCycler PCR in 93 nasopharyngeal secretion specimens collected from infants and young children. The assay was compared with virus isolation, routine PCR, nested PCR, and enzyme-linked immunosorbent assay (ELISA). This TaqMan assay had a sensitivity of 1 x 10(2) cDNA copies/microl with a dynamic range between 1 x 10(2) and 1 x 10(7) cDNA copies/microl, which was the same as that of nested PCR, but 10 times more sensitive than routine PCR. The specificity of the assay was evaluated by comparing hRSV with polivirus type 1, coxsackie virus type 2, influenza A, influenza B and adenovirus type 7. A PCR product of the expected size (195 bp) was produced and fluorescence signal detected for hRSV, but not for any of the other viruses. The results in LightCycler and Rotor-Gene instrument were consistent. Forty-four specimens (43.9%) were hRSV-positive with this assay and 4 (4/93,4.3%) were hRSV-positive with ELISA, showing rather low correlation between the two methods. No visible relation was found between the concentration of hRSV RNA and severity of the disease. This assay is rapid, sensitive, specific and quantitative, and has the potential of wide application for early diagnosis of hRSV infection and evaluation of the therapeutic effect.

  20. A uniform bacterial growth potential assay for different water types.

    PubMed

    Farhat, Nadia; Hammes, Frederik; Prest, Emmanuelle; Vrouwenvelder, Johannes

    2018-06-06

    The bacterial growth potential is important to understand and manage bacterial regrowth-related water quality concerns. Bacterial growth potential depends on growth promoting/limiting compounds, therefore, nutrient availability is the key factor governing bacterial growth potential. Selecting proper tools for bacterial growth measurement is essential for routine implementation of the growth potential measurement. This study proposes a growth potential assay that is universal and can be used for different water types and soil extract without restrictions of pure culture or cultivability of the bacterial strain. The proposed assay measures the sample bacterial growth potential by using the indigenous community as inocula. Flow cytometry (FCM) and adenosine tri-phosphate (ATP) were used to evaluate the growth potential of six different microbial communities indigenous to the sample being analyzed, with increasing carbon concentrations. Bottled mineral water, non-chlorinated tap water, seawater, river water, wastewater effluent and a soil organic carbon extract were analyzed. Results showed that indigenous bacterial communities followed normal batch growth kinetics when grown on naturally present organic carbon. Indigenous bacterial growth could detect spiked organic carbon concentrations as low as 10 μg/L. The indigenous community in all samples responded proportionally to the increase in acetate-carbon and proportional growth could be measured with both FCM and ATP. Bacterial growth was proportional to the carbon concentration but not the same proportion factor for the different water samples tested. The effect of inoculating the same water with different indigenous microbial communities on the growth potential was also examined. The FCM results showed that the highest increase in total bacterial cell concentration was obtained with bacteria indigenous to the water sample. The growth potential assay using indigenous bacterial community revealed consistent results

  1. Contamination control and assay results for the Majorana Demonstrator ultra clean components

    NASA Astrophysics Data System (ADS)

    Christofferson, C. D.; Abgrall, N.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O'Shaughnessy, C.; Othman, G.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Rouf, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.

    2018-01-01

    The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

  2. Heritability of Nociception IV: Neuropathic pain assays are genetically distinct across methods of peripheral nerve injury

    PubMed Central

    Young, Erin E.; Costigan, Michael; Herbert, Teri A.; Lariviere, William R.

    2013-01-01

    Prior genetic correlation analysis of 22 heritable behavioral measures of nociception and hypersensitivity in the mouse identified five genetically distinct pain types. In the present study, we reanalyzed that dataset and included the results of an additional nine assays of nociception and hypersensitivity to: 1) replicate the previously identified five pain types; 2) test whether any of the newly added pain assays represent novel genetically distinct pain types; 3) test the level of genetic relatedness among nine commonly employed neuropathic pain assays. Multivariate analysis of pairwise correlations between assays shows that the newly added zymosan-induced heat hypersensitivity assay does not conform to the two previously identified groups of heat hypersensitivity assays and cyclophosphamide-induced cystitis, the first organ-specific visceral pain model examined, is genetically distinct from other inflammatory assays. The four included mechanical hypersensitivity assays are genetically distinct, and do not comprise a single pain type as previously reported. Among the nine neuropathic pain assays including autotomy, chemotherapy, nerve ligation and spared nerve injury assays, at least four genetically distinct types of neuropathic sensory abnormalities were identified, corresponding to differences in nerve injury method. In addition, two itch assays and Comt genotype were compared to the expanded set of nociception and hypersensitivity assays. Comt genotype was strongly related only to spontaneous inflammatory nociception assays. These results indicate the priority for continued investigation of genetic mechanisms in several assays newly identified to represent genetically distinct pain types. PMID:24071598

  3. Development of recombinase polymerase amplification assays for the rapid detection of peste des petits ruminants virus.

    PubMed

    Zhang, Yongning; Wang, Jianchang; Zhang, Zhou; Mei, Lin; Wang, Jinfeng; Wu, Shaoqiang; Lin, Xiangmei

    2018-04-01

    Peste des petits ruminants (PPR) is a severe infectious disease of small ruminants caused by PPR virus (PPRV). Rapid and sensitive detection of PPRV is critical for controlling PPR. This report describes the development and evaluation of a conventional reverse transcription recombinase polymerase amplification (RT-RPA) assay and a real-time RT-RPA assay, targeting the PPRV N gene. Sensitivity analysis revealed that the conventional RT-RPA assay could detect 852 copies of standard PPRV RNA per reaction at 95% probability within 20 min at 41 °C, and the real-time RT-RPA assay could detect 103 copies of RNA molecules per reaction at 95% probability. Specificity analysis showed that both assays have no cross-reactivity with nucleic acid templates prepared from other selected viruses or common pathogens. Clinical evaluation using 162 ovine and hircine serum and nasal swab samples showed that the performance of both the real-time RT-RPA assay and the conventional RT-RPA assay were comparable to that of real-time RT-PCR. The overall agreements between real-time RT-PCR and real-time RT-RPA, and conventional RT-RPA were 99.4% (161/162) and 98.8% (160/162), respectively. The R 2 value of real-time RT-RPA and real-time RT-PCR was 0.900 by linear regression analysis. Our results suggest that both RT-RPA assays have a potential application in the rapid, sensitive and specific detection of PPRV. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Analysis of hepatitis B surface antigen (HBsAg) using high-sensitivity HBsAg assays in hepatitis B virus carriers in whom HBsAg seroclearance was confirmed by conventional assays.

    PubMed

    Ozeki, Itaru; Nakajima, Tomoaki; Suii, Hirokazu; Tatsumi, Ryoji; Yamaguchi, Masakatsu; Kimura, Mutsuumi; Arakawa, Tomohiro; Kuwata, Yasuaki; Ohmura, Takumi; Hige, Shuhei; Karino, Yoshiyasu; Toyota, Joji

    2018-02-01

    We investigated the utility of high-sensitivity hepatitis B surface antigen (HBsAg) assays compared with conventional HBsAg assays. Using serum samples from 114 hepatitis B virus (HBV) carriers in whom HBsAg seroclearance was confirmed by conventional HBsAg assays (cut-off value, 0.05 IU/mL), the amount of HBsAg was re-examined by high-sensitivity HBsAg assays (cut-off value, 0.005 IU/mL). Cases negative for HBsAg in both assays were defined as consistent cases, and cases positive for HBsAg in the high-sensitivity HBsAg assay only were defined as discrepant cases. There were 55 (48.2%) discrepant cases, and the range of HBsAg titers determined by high-sensitivity HBsAg assays was 0.005-0.056 IU/mL. Multivariate analysis showed that the presence of nucleos(t)ide analog therapy, liver cirrhosis, and negative anti-HBs contributed to the discrepancies between the two assays. Cumulative anti-HBs positivity rates among discrepant cases were 12.7%, 17.2%, 38.8%, and 43.9% at baseline, 1 year, 3 years, and 5 years, respectively, whereas the corresponding rates among consistent cases were 50.8%, 56.0%, 61.7%, and 68.0%, respectively. Hepatitis B virus DNA negativity rates were 56.4% and 81.4% at baseline, 51.3% and 83.3% at 1 year, and 36.8% and 95.7% at 3 years, among discrepant and consistent cases, respectively. Hepatitis B surface antigen reversion was observed only in discrepant cases. Re-examination by high-sensitivity HBsAg assays revealed that HBsAg was positive in approximately 50% of cases. Cumulative anti-HBs seroconversion rates and HBV-DNA seroclearance rates were lower in these cases, suggesting a population at risk for HBsAg reversion. © 2017 The Japan Society of Hepatology.

  5. Cross reactions elicited by serum 17-OH progesterone and 11-desoxycortisol in cortisol assays.

    PubMed

    Brossaud, Julie; Barat, Pascal; Gualde, Dominique; Corcuff, Jean-Benoît

    2009-09-01

    Different pathophysiological situations such as congenital adrenal hyperplasia, adrenocortical carcinoma, metyrapone treatment, etc. elicit specificity problems with serum cortisol assay. We assayed cortisol using 2 kits and performed cross reaction studies as well as multiple regression analysis using 2 other steroids: 11-desoxycortisol and 17-OH progesterone. Analysis showed the existence of an analytical bias. Importantly, significantly different biases were demonstrated in newborns or patients taking metyrapone. Multiple regression analysis and cross reaction studies showed that 11-desoxycortisol level significantly influenced cortisol determination. Moreover, despite using the normal ranges provided by manufacturers discrepant results occurred such as 17% discordance in the diagnosis of hypocorticism in infants. We wish to raise awareness about the consequences of the (lack of) specificity of cortisol assays with regard to the evaluation of hypocorticism in infants or when "unusual" steroids may be increased.

  6. Protein immobilization techniques for microfluidic assays

    PubMed Central

    Kim, Dohyun; Herr, Amy E.

    2013-01-01

    Microfluidic systems have shown unequivocal performance improvements over conventional bench-top assays across a range of performance metrics. For example, specific advances have been made in reagent consumption, throughput, integration of multiple assay steps, assay automation, and multiplexing capability. For heterogeneous systems, controlled immobilization of reactants is essential for reliable, sensitive detection of analytes. In most cases, protein immobilization densities are maximized, while native activity and conformation are maintained. Immobilization methods and chemistries vary significantly depending on immobilization surface, protein properties, and specific assay goals. In this review, we present trade-offs considerations for common immobilization surface materials. We overview immobilization methods and chemistries, and discuss studies exemplar of key approaches—here with a specific emphasis on immunoassays and enzymatic reactors. Recent “smart immobilization” methods including the use of light, electrochemical, thermal, and chemical stimuli to attach and detach proteins on demand with precise spatial control are highlighted. Spatially encoded protein immobilization using DNA hybridization for multiplexed assays and reversible protein immobilization surfaces for repeatable assay are introduced as immobilization methods. We also describe multifunctional surface coatings that can perform tasks that were, until recently, relegated to multiple functional coatings. We consider the microfluidics literature from 1997 to present and close with a perspective on future approaches to protein immobilization. PMID:24003344

  7. Molecular Identification, Enzyme Assay, and Metabolic Profiling of Trichoderma spp.

    PubMed

    Bae, Soo-Jung; Park, Young-Hwan; Bae, Hyeun-Jong; Jeon, Junhyun; Bae, Hanhong

    2017-06-28

    The goal of this study was to identify and characterize selected Trichoderma isolates by metabolic profiling and enzyme assay for evaluation of their potential as biocontrol agents against plant pathogens. Trichoderma isolates were obtained from the Rural Development Administration Genebank Information Center (Wanju, Republic of Korea). Eleven Trichoderma isolates were re-identified using ribosomal DNA internal transcribed spacer (ITS) regions. ITS sequence results showed new identification of Trichoderma isolates. In addition, metabolic profiling of the ethyl acetate extracts of the liquid cultures of five Trichoderma isolates that showed the best anti- Phytophthora activities was conducted using gas chromatography-mass spectrometry. Metabolic profiling revealed that Trichoderma isolates shared common metabolites with well-known antifungal activities. Enzyme assays indicated strong cell walldegrading enzyme activities of Trichoderma isolates. Overall, our results indicated that the selected Trichoderma isolates have great potential for use as biocontrol agents against plant pathogens.

  8. Development of a Rapid Insulin Assay by Homogenous Time-Resolved Fluorescence

    PubMed Central

    Vallaghe, Julie; Gregor, Nathalie; Donthamsetti, Prashant; Harris, Paul E.; Pierre, Nicolas; Freyberg, Robin; Charrier-Savournin, Fabienne; Javitch, Jonathan A.; Freyberg, Zachary

    2016-01-01

    Direct measurement of insulin is critical for basic and clinical studies of insulin secretion. However, current methods are expensive and time-consuming. We developed an insulin assay based on homogenous time-resolved fluorescence that is significantly more rapid and cost-effective than current commonly used approaches. This assay was applied effectively to an insulin secreting cell line, INS-1E cells, as well as pancreatic islets, allowing us to validate the assay by elucidating mechanisms by which dopamine regulates insulin release. We found that dopamine functioned as a significant negative modulator of glucose-stimulated insulin secretion. Further, we showed that bromocriptine, a known dopamine D2/D3 receptor agonist and newly approved drug used for treatment of type II diabetes mellitus, also decreased glucose-stimulated insulin secretion in islets to levels comparable to those caused by dopamine treatment. PMID:26849707

  9. Screening assays of termite gut microbes that potentially as probiotic for human to digest cellulose as new food source

    NASA Astrophysics Data System (ADS)

    Abdullah, R.; Ananda, K. R. T.; Wijanarka

    2018-05-01

    According to UN, earth population will increase approximately 7.3 billion people up to 11.2 billion from 2015 until 2100. On the other side, food needs are not balance with the availability of food on earth. People of the world need solution for a new food source. By cellulose digesting ability, people analyzed can consume cellulose as the new food source to get glucose. The aims of research is obtaining termite gut cellulase bacteria selected which is potential as probiotic to split cellulose. Method used was as follows; isolation of termite gut microbes, microbial cellulase purification by screening method and probiotic test includes microbial pathogenicity test and human stomach acid and salt osmotic concentration resistance test. The result shows, 3 pure isolates of termite gut microbes can break down cellulose in the medium 1% CMC and 0.1% congo red (indicator of cellulose degradation activity) and life at pH 2- 2.5 and osmotic salt condition. Two isolates show the activity of gamma hemolysis (non-pathogenic in terms of pathogenicity on human blood). In conclusion, there are isolated termite gut microbes can be used as probiotic candidate for human to digest cellulose of the new food source for global food scarcity era.

  10. A high-throughput assay for enzymatic polyester hydrolysis activity by fluorimetric detection.

    PubMed

    Wei, Ren; Oeser, Thorsten; Billig, Susan; Zimmermann, Wolfgang

    2012-12-01

    A fluorimetric assay for the fast determination of the activity of polyester-hydrolyzing enzymes in a large number of samples has been developed. Terephthalic acid (TPA) is a main product of the enzymatic hydrolysis of polyethylene terephthalate (PET), a synthetic polyester. Terephthalate has been quantified following its conversion to the fluorescent 2-hydroxyterephthalate by an iron autoxidation-mediated generation of free hydroxyl radicals. The assay proved to be robust at different buffer concentrations, reaction times, pH values, and in the presence of proteins. A validation of the assay was performed by analyzing TPA formation from PET films and nanoparticles catalyzed by a polyester hydrolase from Thermobifida fusca KW3 in a 96-well microplate format. The results showed a close correlation (R(2) = 0.99) with those obtained by a considerably more tedious and time-consuming HPLC method, suggesting the aptness of the fluorimetric assay for a high-throughput screening for polyester hydrolases. The method described in this paper will facilitate the detection and development of biocatalysts for the modification and degradation of synthetic polymers. The fluorimetric assay can be used to quantify the amount of TPA obtained as the final degradation product of the enzymatic hydrolysis of PET. In a microplate format, this assay can be applied for the high-throughput screening of polyester hydrolases. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Development of an opioid self-administration assay to study drug seeking in zebrafish.

    PubMed

    Bossé, Gabriel D; Peterson, Randall T

    2017-09-29

    The zebrafish (Danio rerio) has become an excellent tool to study mental health disorders, due to its physiological and genetic similarity to humans, ease of genetic manipulation, and feasibility of small molecule screening. Zebrafish have been shown to exhibit characteristics of addiction to drugs of abuse in non-contingent assays, including conditioned place preference, but contingent assays have been limited to a single assay for alcohol consumption. Using inexpensive electronic, mechanical, and optical components, we developed an automated opioid self-administration assay for zebrafish, enabling us to measure drug seeking and gain insight into the underlying biological pathways. Zebrafish trained in the assay for five days exhibited robust self-administration, which was dependent on the function of the μ-opioid receptor. In addition, a progressive ratio protocol was used to test conditioned animals for motivation. Furthermore, conditioned fish continued to seek the drug despite an adverse consequence and showed signs of stress and anxiety upon withdrawal of the drug. Finally, we validated our assay by confirming that self-administration in zebrafish is dependent on several of the same molecular pathways as in other animal models. Given the ease and throughput of this assay, it will enable identification of important biological pathways regulating drug seeking and could lead to the development of new therapeutic molecules to treat addiction. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Assessing transmissible spongiform encephalopathy species barriers with an in vitro prion protein conversion assay

    USGS Publications Warehouse

    Johnson, Christopher J.; Carlson, Christina M.; Morawski, Aaron R.; Manthei, Alyson; Cashman, Neil R.

    2015-01-01

    Studies to understanding interspecies transmission of transmissible spongiform encephalopathies (TSEs, prion diseases) are challenging in that they typically rely upon lengthy and costly in vivo animal challenge studies. A number of in vitro assays have been developed to aid in measuring prion species barriers, thereby reducing animal use and providing quicker results than animal bioassays. Here, we present the protocol for a rapid in vitroprion conversion assay called the conversion efficiency ratio (CER) assay. In this assay cellular prion protein (PrPC) from an uninfected host brain is denatured at both pH 7.4 and 3.5 to produce two substrates. When the pH 7.4 substrate is incubated with TSE agent, the amount of PrPC that converts to a proteinase K (PK)-resistant state is modulated by the original host’s species barrier to the TSE agent. In contrast, PrPC in the pH 3.5 substrate is misfolded by any TSE agent. By comparing the amount of PK-resistant prion protein in the two substrates, an assessment of the host’s species barrier can be made. We show that the CER assay correctly predicts known prion species barriers of laboratory mice and, as an example, show some preliminary results suggesting that bobcats (Lynx rufus) may be susceptible to white-tailed deer (Odocoileus virginianus) chronic wasting disease agent.

  13. C14 Assays and Autoradiographic Studies on the Rooster Comb

    PubMed Central

    Balazs, Endre A.; Szirmai, John A.; Bergendahl, Gudrun

    1959-01-01

    The distribution of C14 was studied in various parts of the rooster comb following treatment with testosterone. The value of gas-phase assay of C14 in tissue has been demonstrated and the results compared with those of autoradiographic studies on the same tissue. The results of these experiments showed that androgen treatment significantly increases the rate of incorporation of C14 in various parts of the comb. The specific activity of carbon in the comb, cornea, and liver differed, depending on which precursor, viz. glucose-6-C14, glucose-1-C14, and glucuronolactone-U-C14, was administered. The highest values were obtained after the administration of glucose-6-C14; glucuronolactone-U-C14 gave the lowest specific activity. The specific activity of carbon in different parts of the comb showed considerable variation. Carbon assay of serial sections of the comb cut at various planes showed that the specific activity of carbon was highest in the mucoid layer. Both C14 assays and autoradiograms indicate that C14 is also present in other parts of the comb. As seen in autoradiography, the concentration of C14 was highest in the epithelium, in the blood vessel walls, and in the avascular collagenous tissue. These results, and indications from previous studies, suggest that the high specific activity of carbon in the mucoid layer is due mainly to the presence of C14-labelled hyaluronic acid. Autoradiograms and PAS staining suggest that a significant amount of C14 is also incorporated into the glycoproteins associated with the collagen fibers. PMID:13654453

  14. Thyroglobulin (Tg) Testing Revisited: Tg Assays, TgAb Assays, and Correlation of Results With Clinical Outcomes.

    PubMed

    Netzel, Brian C; Grebe, Stefan K G; Carranza Leon, B Gisella; Castro, M Regina; Clark, Penelope M; Hoofnagle, Andrew N; Spencer, Carole A; Turcu, Adina F; Algeciras-Schimnich, Alicia

    2015-08-01

    Measurement of thyroglobulin (Tg) by mass spectrometry (Tg-MS) is emerging as a tool for accurate Tg quantification in patients with anti-Tg autoantibodies (TgAbs). The objective of the study was to perform analytical and clinical evaluations of two Tg-MS assays in comparison with immunometric Tg assays (Tg-IAs) and Tg RIAs (Tg-RIAs) in a cohort of thyroid cancer patients. A total of 589 samples from 495 patients, 243 TgAb-/252 TgAb+, were tested by Beckman, Roche, Siemens-Immulite, and Thermo-Brahms Tg and TgAb assays, two Tg-RIAs, and two Tg-MS assays. The frequency of TgAb+ was 58%, 41%, 27%, and 39% for Roche, Beckman, Siemens-Immulite, and Thermo-Brahms, respectively. In TgAb- samples, clinical sensitivities and specificities of 100% and 74%-100%, respectively, were observed across all assays. In TgAb+ samples, all Tg-IAs demonstrated assay-dependent Tg underestimation, ranging from 41% to 86%. In TgAb+ samples, the use of a common cutoff (0.5 ng/mL) for the Tg-MS, three Tg-IAs, and the USC-RIA improved the sensitivity for the Tg-MSs and Tg-RIAs when compared with the Tg-IAs. In up to 20% of TgAb+ cases, Tg-IAs failed to detect Tg that was detectable by Tg-MS. In Tg-RIAs false-high biases were observed in TgAb+ samples containing low Tg concentrations. Tg-IAs remain the method of choice for Tg quantitation in TgAb- patients. In TgAb+ patients with undetectable Tg by immunometric assay, the Tg-MS will detect Tg in up to 20% additional cases. The Tg-RIA will detect Tg in approximately 35% cases, but a significant proportion of these will be clinical false-positive results. The undetectable Tg-MS seen in approximately 40% of TgAb+ cases in patients with disease need further evaluation.

  15. DNA damage evaluation of hydroxyapatite on fibroblast cell L929 using the single cell gel electrophoresis assay.

    PubMed

    Rajab, N F; Yaakob, T A; Ong, B Y; Hamid, M; Ali, A M; Annuar, B O; Inayat-Hussain, S H

    2004-05-01

    Hydroxyapatite is the main component of the bone which is a potential biomaterial substance that can be applied in orthopaedics. In this study, the biocompatibility of this biomaterial was assessed using an in vitro technique. The cytotoxicity and genotoxicity effect of HA2 and HA3 against L929 fibroblast cell was evaluated using the MTT Assay and Alkaline Comet Assay respectively. Both HA2 and HA3 compound showed low cytotoxicity effect as determined using MTT Assay. Cells viability following 72 hours incubation at maximum concentration of both HA2 and HA3 (200 mg/ml) were 75.3 +/- 8.8% and 86.7 +/- 13.1% respectively. However, the cytotoxicity effect of ZnSO4.7H2O as a positive control showed an IC50 values of 46 mg/ml (160 microM). On the other hand, both HA2 and HA3 compound showed a slight genotoxicity effect as determined using the Alkaline Comet Assay following incubation at the concentration 200 mg/ml for 72 hours. This assay has been widely used in genetic toxicology to detect DNA strand breaks and alkali-labile site. The percentage of the cells with DNA damage for both substance was 27.7 +/- 1.3% and 15.6 +/- 1.0% for HA2 and HA3 respectively. Incubation of the cells for 24 hours with 38 microg/ml (IC25) of positive control showed an increase in percentage of cells with DNA damage (67.5 +/- 0.7%). In conclusion, our study indicated that both hydroxyapatite compounds showed a good biocompatibility in fibroblast cells.

  16. Development of a high-throughput colorimetric Zika virus infection assay.

    PubMed

    Müller, Janis A; Harms, Mirja; Schubert, Axel; Mayer, Benjamin; Jansen, Stephanie; Herbeuval, Jean-Philippe; Michel, Detlef; Mertens, Thomas; Vapalahti, Olli; Schmidt-Chanasit, Jonas; Münch, Jan

    2017-04-01

    Zika virus (ZIKV) is an emerging pathogen that causes congenital infections which may result in birth defects, such as microcephaly. Currently, no approved treatment or vaccination is available. ZIKV can be readily detected in cell culture where virally infected cells are normally stained by specific antibodies. As ZIKV regularly causes a cytopathic effect, we were wondering whether this viral property can be used to quantitatively determine viral infectivity. We here describe the use of an 3-[4,5-dimethyl-2-thiazolyl]-2,5-diphenyl-2H-tetrazolium bromide-(MTT)-based cell viability assay that allows to determine ZIKV-induced cell death. We show that this colorimetric assay quantifies ZIKV infection over a broad range of viral dilutions in both monkey and human cells. It allows to determine inhibitory activities of antivirals that block ZIKV or to define the neutralizing antibody titers of ZIKV antisera. This MTT-based ZIKV detection assay can be evaluated by naked eye or computational tools, has a broad linear range, does not require large equipment or costly reagents, and thus represents a promising alternative to antibody-based assays, in particular in resource-poor settings. We propose to use this simple, fast, and cheap method for quantification of ZIKV neutralizing antibodies and testing of antiviral compounds.

  17. Availability of highly sensitive troponin assays and acute coronary syndrome care: insights from the SNAPSHOT registry.

    PubMed

    Cullen, Louise; French, John K; Briffa, Tom G; Redfern, Julie; Hammett, Christopher J K; Brieger, David B; Parsonage, William A; Lefkovits, Jeffrey; Ellis, Chris; Astley, Carolyn; Howell, Tegwen Eleanor; Elliott, John M; Chew, Derek P B

    2015-01-19

    To examine differences in care and inhospital course of patients with possible acute coronary syndrome (ACS) in Australia and New Zealand based on whether a highly sensitive (hs) troponin assay was used at the hospital to which they presented. A snapshot study of consecutive patients presenting to hospitals in Australia and New Zealand from 14 to 27 May 2012 with possible ACS. Rates of major adverse cardiac events (inhospital death, new or recurrent myocardial infarction, stroke, cardiac arrest or worsening heart failure); association between assay type and outcome (via propensity score matching and a generalised estimating equation [GEE]; averages of the predicted outcomes among patients who were treated with and without the availability of an hs assay (via inverse probability-weighting [IPW] with regression-adjusted estimators). 4371 patients with possible ACS were admitted to 283 hospitals. Over half of the hospitals (156 [55%]) reported using the hs assay and most patients (2624 [60%]) had hs tests (P = 0.004). Use of the hs assay was independent of hospital coronary revascularisation capability. Patients tested with the hs assay had more non-invasive investigations (exercise tests, stress echocardiography, stress nuclear scans, and computed tomography coronary angiography) than those tested with the sensitive assay. However, there were no differences between the groups in rates of angiography or revascularisation. All adjusted analyses showed a consistently lower rate of inhospital events, including recurrent heart failure in patients for whom the hs assay was used (GEE odds ratio, 0.75; 95% CI, 0.60-0.94; P = 0.014); IPW analysis showed a 2.3% absolute reduction in these events with the use of the hs assay (P = 0.018). Use of hs troponin testing of patients hospitalised with possible ACS was associated with an increased rate of non-invasive cardiac investigations and fewer inhospital adverse events.

  18. Comparison of Six Automated Treponema-Specific Antibody Assays.

    PubMed

    Park, Borae G; Yoon, Jihoon G; Rim, John Hoon; Lee, Anna; Kim, Hyon-Suk

    2016-01-01

    Six different Treponema (TP)-specific immunoassays were compared to the fluorescent treponemal antibody absorption (FTA-ABS) test. A total of 615 samples were tested. The overall percent agreement, analytical sensitivity, and analytical specificity of each assay compared to the FTA-ABS test were as follows: Architect Syphilis TP, 99.2%, 96.8%, and 100%; Cobas Syphilis, 99.8%, 99.4%, and 100%; ADVIA Centaur Syphilis, 99.8%, 99.4%, and 100%; HISCL Anti-TP assay kit, 99.7%, 98.7%, and 100%; Immunoticles Auto3 TP, 99.0%, 97.5%, and 99.6%; Mediace TPLA, 98.0%, 98.1%, and 98.0%. All results that were discrepant between the TP-specific assays were associated with samples from noninfectious cases (11 immunoassay false positives and 7 from previous syphilis cases). Our study demonstrated that TP-specific immunoassays generally showed high sensitivities, specificities, and percentages of agreement compared to FTA-ABS, with rare cases of false-positive or false-negative results. Therefore, most TP-specific immunoassays are acceptable for use in screening for syphilis. However, it is important to perform a thorough review of a patient's clinical and treatment history for interpreting the results of syphilis serology. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  19. Studies on the genotoxic properties of essential oils with Bacillus subtilis rec-assay and Salmonella/microsome reversion assay.

    PubMed

    Zani, F; Massimo, G; Benvenuti, S; Bianchi, A; Albasini, A; Melegari, M; Vampa, G; Bellotti, A; Mazza, P

    1991-06-01

    Genotoxic properties of essential oils from Anthemis nobilis L., Artemisia dracunculus L., Salvia officinalis L., Salvia sclarea L., Satureja hortensis L., Satureja montana L., Thymus capitatus L., Thymus citriodorus Schreb., Thymus vulgaris L., Citrus bergamia Risso, were studied with Bacillus subtilis rec-assay and Salmonella/microsome reversion assay. The essential oil of Artemisia dracunculus L. "Piemontese" turned out to be active in the rec-assay but not in the Salmonella test. DNA-damaging activity was demonstrated to be due to the estragol component of the oil. Advantages of the combined use of these two short-term microbial assays in genotoxic studies are discussed.

  20. Use of In Vitro Assays to Assess Immunogenicity Risk of Antibody-Based Biotherapeutics

    PubMed Central

    Joubert, Marisa K.; Deshpande, Meghana; Yang, Jane; Reynolds, Helen; Bryson, Christine; Fogg, Mark; Baker, Matthew P.; Herskovitz, Jonathan; Goletz, Theresa J.; Zhou, Lei; Moxness, Michael; Flynn, Gregory C.; Narhi, Linda O.; Jawa, Vibha

    2016-01-01

    An In Vitro Comparative Immunogenicity Assessment (IVCIA) assay was evaluated as a tool for predicting the potential relative immunogenicity of biotherapeutic attributes. Peripheral blood mononuclear cells from up to 50 healthy naïve human donors were monitored up to 8 days for T-cell proliferation, the number of IL-2 or IFN-γ secreting cells, and the concentration of a panel of secreted cytokines. The response in the assay to 10 monoclonal antibodies was found to be in agreement with the clinical immunogenicity, suggesting that the assay might be applied to immunogenicity risk assessment of antibody biotherapeutic attributes. However, the response in the assay is a measure of T-cell functional activity and the alignment with clinical immunogenicity depends on several other factors. The assay was sensitive to sequence variants and could differentiate single point mutations of the same biotherapeutic. Nine mAbs that were highly aggregated by stirring induced a higher response in the assay than the original mAbs before stirring stress, in a manner that did not match the relative T-cell response of the original mAbs. In contrast, mAbs that were glycated by different sugars (galactose, glucose, and mannose) showed little to no increase in response in the assay above the response to the original mAbs before glycation treatment. The assay was also used successfully to assess similarity between multiple lots of the same mAb, both from the same manufacturer and from different manufacturers (biosimilars). A strategy for using the IVCIA assay for immunogenicity risk assessment during the entire lifespan development of biopharmaceuticals is proposed. PMID:27494246

  1. 21 CFR 864.7415 - Abnormal hemoglobin assay.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Abnormal hemoglobin assay. 864.7415 Section 864... hemoglobin assay. (a) Identification. An abnormal hemoglobin assay is a device consisting of the reagents... hemoglobin types. (b) Classification. Class II (performance standards). [45 FR 60618, Sept. 12, 1980] ...

  2. 21 CFR 864.7415 - Abnormal hemoglobin assay.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Abnormal hemoglobin assay. 864.7415 Section 864... hemoglobin assay. (a) Identification. An abnormal hemoglobin assay is a device consisting of the reagents... hemoglobin types. (b) Classification. Class II (performance standards). [45 FR 60618, Sept. 12, 1980] ...

  3. Lipopolysaccharide Specific Immunochromatography Based Lateral Flow Assay for Serogroup Specific Diagnosis of Leptospirosis in India

    PubMed Central

    Vanithamani, Shanmugam; Shanmughapriya, Santhanam; Narayanan, Ramasamy; Raja, Veerapandian; Kanagavel, Murugesan; Sivasankari, Karikalacholan; Natarajaseenivasan, Kalimuthusamy

    2015-01-01

    Background Leptospirosis is a re-emerging infectious disease that is under-recognized due to low-sensitivity and cumbersome serological tests. MAT is the gold standard test and it is the only serogroup specific test used till date. Rapid reliable alternative serogroup specific tests are needed for surveillance studies to identify locally circulating serogroups in the study area. Methods/Principal Findings In the present investigation the serological specificity of leptospiral lipopolysaccharides (LPS) was evaluated by enzyme linked immunosorbent assay (ELISA), dot blot assay and rapid immunochromatography based lateral flow assay (ICG-LFA). Sera samples from 120 MAT positive cases, 174 cases with febrile illness other than leptospirosis, and 121 seronegative healthy controls were evaluated for the diagnostic sensitivity and specificity of the developed assays. LPS was extracted from five locally predominant circulating serogroups including: Australis (27.5%), Autumnalis (11.7%), Ballum (25.8%), Grippotyphosa (12.5%), Pomona (10%) and were used as antigens in the diagnostics to detect IgM antibodies in patients’ sera. The sensitivity observed by IgM ELISA and dot blot assay using various leptospiral LPS was >90% for homologous sera. Except for Ballum LPS, no other LPS showed cross-reactivity to heterologous sera. An attempt was made to develop LPS based ICG-LFA for rapid and sensitive serogroup specific diagnostics of leptospirosis. The developed ICG-LFA showed sensitivity in the range between 93 and 100% for homologous sera. The Wilcoxon analysis showed LPS based ICG-LFA did not differ significantly from the gold standard MAT (P>0.05). Conclusion The application of single array of LPS for serogroup specific diagnosis is first of its kind. The developed assay could potentially be evaluated and employed for as MAT alternative. PMID:26340095

  4. Introducing MINA--The Molecularly Imprinted Nanoparticle Assay.

    PubMed

    Shutov, Roman V; Guerreiro, Antonio; Moczko, Ewa; de Vargas-Sansalvador, Isabel Perez; Chianella, Iva; Whitcombe, Michael J; Piletsky, Sergey A

    2014-03-26

    A new ELISA- (enzyme-linked immunosorbent assay)-like assay is demonstrated in which no elements of biological origin are used for molecular recognition or signaling. Composite imprinted nanoparticles that contain a catalytic core and which are synthesized by using a solid-phase approach can simultaneously act as recognition/signaling elements, and be used with minimal modifications to standard assay protocols. This assay provides a new route towards replacement of unstable biomolecules in immunoassays. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Enhanced Reverse Transcription-PCR Assay for Detection of Norovirus Genogroup I

    PubMed Central

    Dreier, Jens; Störmer, Melanie; Mäde, Dietrich; Burkhardt, Sabine; Kleesiek, Knut

    2006-01-01

    We have developed a one-tube reverse transcription (RT)-PCR method using the real-time TaqMan PCR system for the detection of norovirus genogroup I (NV GGI). By introduction of a novel probe based on locked nucleic acid technology, we enhanced the sensitivity of the assay compared to those of conventional TaqMan probes. The sensitivity of the NV GGI RT-PCR was determined by probit analysis with defined RNA standards and quantified norovirus isolates to 711 copies/ml (95% detection limit). In order to detect PCR inhibition, we included a heterologous internal control (IC) system based on phage MS2. This internally controlled RT-PCR was tested on different real-time PCR platforms, LightCycler, Rotorgene, Mastercycler EP realplex, and ABI Prism. Compared to the assay without an IC, the duplex RT-PCR exhibited no reduction in sensitivity in clinical samples. In combination with an established NV GGII real-time RT-PCR, we used the novel assay in a routine assay for diagnosis of clinical and food-borne norovirus infection. We applied this novel assay to analyze outbreaks of nonbacterial acute gastroenteritis. Norovirus of GGI was detected in these outbreaks. Sequence and similarity plot analysis of open reading frame 1 (ORF1) and ORF2 showed two genotypes, GGI/2 and GGI/4, in semiclosed communities. PMID:16891482

  6. Medical Devices; Immunology and Microbiology Devices; Classification of the Assayed Quality Control Material for Clinical Microbiology Assays. Final order.

    PubMed

    2017-07-27

    The Food and Drug Administration (FDA, Agency, or we) is classifying the assayed quality control material for clinical microbiology assays into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the assayed quality control material for clinical microbiology assays' classification. The Agency is classifying the device into class II (special controls) to provide a reasonable assurance of safety and effectiveness of the device.

  7. A simple and novel modification of comet assay for determination of bacteriophage mediated bacterial cell lysis.

    PubMed

    Khairnar, Krishna; Sanmukh, Swapnil; Chandekar, Rajshree; Paunikar, Waman

    2014-07-01

    The comet assay is the widely used method for in vitro toxicity testing which is also an alternative to the use of animal models for in vivo testing. Since, its inception in 1984 by Ostling and Johansson, it is being modified frequently for a wide range of application. In spite of its wide applicability, unfortunately there is no report of its application in bacteriophages research. In this study, a novel application of comet assay for the detection of bacteriophage mediated bacterial cell lysis was described. The conventional methods in bacteriophage research for studying bacterial lysis by bacteriophages are plaque assay method. It is time consuming, laborious and costly. The lytic activity of bacteriophage devours the bacterial cell which results in the release of bacterial genomic material that gets detected by ethidium bromide staining method by the comet assay protocol. The objective of this study was to compare efficacy of comet assay with different assay used to study phage mediated bacterial lysis. The assay was performed on culture isolates (N=80 studies), modified comet assay appear to have relatively higher sensitivity and specificity than other assay. The results of the study showed that the application of comet assay can be an economical, time saving and less laborious alternative to conventional plaque assay for the detection of bacteriophage mediated bacterial cell lysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. The Effects of Statistical Multiplicity of Infection on Virus Quantification and Infectivity Assays.

    PubMed

    Mistry, Bhaven A; D'Orsogna, Maria R; Chou, Tom

    2018-06-19

    Many biological assays are employed in virology to quantify parameters of interest. Two such classes of assays, virus quantification assays (VQAs) and infectivity assays (IAs), aim to estimate the number of viruses present in a solution and the ability of a viral strain to successfully infect a host cell, respectively. VQAs operate at extremely dilute concentrations, and results can be subject to stochastic variability in virus-cell interactions. At the other extreme, high viral-particle concentrations are used in IAs, resulting in large numbers of viruses infecting each cell, enough for measurable change in total transcription activity. Furthermore, host cells can be infected at any concentration regime by multiple particles, resulting in a statistical multiplicity of infection and yielding potentially significant variability in the assay signal and parameter estimates. We develop probabilistic models for statistical multiplicity of infection at low and high viral-particle-concentration limits and apply them to the plaque (VQA), endpoint dilution (VQA), and luciferase reporter (IA) assays. A web-based tool implementing our models and analysis is also developed and presented. We test our proposed new methods for inferring experimental parameters from data using numerical simulations and show improvement on existing procedures in all limits. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  9. Development of a Kinetic Assay for Late Endosome Movement.

    PubMed

    Esner, Milan; Meyenhofer, Felix; Kuhn, Michael; Thomas, Melissa; Kalaidzidis, Yannis; Bickle, Marc

    2014-08-01

    Automated imaging screens are performed mostly on fixed and stained samples to simplify the workflow and increase throughput. Some processes, such as the movement of cells and organelles or measuring membrane integrity and potential, can be measured only in living cells. Developing such assays to screen large compound or RNAi collections is challenging in many respects. Here, we develop a live-cell high-content assay for tracking endocytic organelles in medium throughput. We evaluate the added value of measuring kinetic parameters compared with measuring static parameters solely. We screened 2000 compounds in U-2 OS cells expressing Lamp1-GFP to label late endosomes. All hits have phenotypes in both static and kinetic parameters. However, we show that the kinetic parameters enable better discrimination of the mechanisms of action. Most of the compounds cause a decrease of motility of endosomes, but we identify several compounds that increase endosomal motility. In summary, we show that kinetic data help to better discriminate phenotypes and thereby obtain more subtle phenotypic clustering. © 2014 Society for Laboratory Automation and Screening.

  10. Comparison of three anti-dsDNA assays: performance and correlation with systemic lupus erythematosus disease activity.

    PubMed

    Venner, Allison A; Ibañez, Dominique; Gladman, Dafna D; Urowitz, Murray B; MacKinnon, Anne; Blasutig, Ivan M; Yip, Paul M

    2013-03-01

    To investigate the BioPlex 2200 multiplex immunoassay and Farrzyme ELISA assays as alternatives to the established Farr radioimmunoassay for the correlation of anti-dsDNA antibodies in the assessment of disease activity in systemic lupus erythematosus (SLE). Standard protocols were used to verify analytical performance claims. Anti-dsDNA antibody levels in SLE patient specimens (N=105) were measured and assessed for clinical performance using manufacturer cut-off limits along with the Systemic Lupus Erythematosus Disease Activity Index 2000 (SLEDAI-2K) score. Assay precision, measurable range and normal reference interval met the manufacturers' stated claims. Agreement between Farr and BioPlex assays was moderate (positive agreement=62%; negative agreement=85%; kappa=0.48), as was agreement between Farr and Farrzyme assays (positive agreement=56%; negative agreement=91%; kappa=0.51). Mean SLEDAI-2K scores differed significantly between the anti-dsDNA positive and negative groups for BioPlex (p=0.0006), but not Farr (p=0.11) or Farrzyme (p=0.34). ROC curve analysis showed a similar area under the curve (AUC) for all three assays (0.76, 0.74, and 0.73 for Farr, BioPlex, and Farrzyme, respectively) in the discrimination of clinically active disease. Furthermore, increased anti-dsDNA levels from BioPlex showed significant correlation with active renal disease. However, results suggested a lower cut-off for the Farrzyme assay for assessment of global disease activity. BioPlex and Farrzyme assays had similar overall agreement with the Farr assay, with BioPlex best reflecting disease activity in SLE patients. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. The SNPforID Assay as a Supplementary Method in Kinship and Trace Analysis

    PubMed Central

    Schwark, Thorsten; Meyer, Patrick; Harder, Melanie; Modrow, Jan-Hendrick; von Wurmb-Schwark, Nicole

    2012-01-01

    Objective Short tandem repeat (STR) analysis using commercial multiplex PCR kits is the method of choice for kinship testing and trace analysis. However, under certain circumstances (deficiency testing, mutations, minute DNA amounts), STRs alone may not suffice. Methods We present a 50-plex single nucleotide polymorphism (SNP) assay based on the SNPs chosen by the SNPforID consortium as an additional method for paternity and for trace analysis. The new assay was applied to selected routine paternity and trace cases from our laboratory. Results and Conclusions Our investigation shows that the new SNP multiplex assay is a valuable method to supplement STR analysis, and is a powerful means to solve complicated genetic analyses. PMID:22851934

  12. A single-islet microplate assay to measure mouse and human islet insulin secretion.

    PubMed

    Truchan, Nathan A; Brar, Harpreet K; Gallagher, Shannon J; Neuman, Joshua C; Kimple, Michelle E

    2015-01-01

    One complication to comparing β-cell function among islet preparations, whether from genetically identical or diverse animals or human organ donors, is the number of islets required per assay. Islet numbers can be limiting, meaning that fewer conditions can be tested; other islet measurements must be excluded; or islets must be pooled from multiple animals/donors for each experiment. Furthermore, pooling islets negates the possibility of performing single-islet comparisons. Our aim was to validate a 96-well plate-based single islet insulin secretion assay that would be as robust as previously published methods to quantify glucose-stimulated insulin secretion from mouse and human islets. First, we tested our new assay using mouse islets, showing robust stimulation of insulin secretion 24 or 48 h after islet isolation. Next, we utilized the assay to quantify mouse islet function on an individual islet basis, measurements that would not be possible with the standard pooled islet assay methods. Next, we validated our new assay using human islets obtained from the Integrated Islet Distribution Program (IIDP). Human islets are known to have widely varying insulin secretion capacity, and using our new assay we reveal biologically relevant factors that are significantly correlated with human islet function, whether displayed as maximal insulin secretion response or fold-stimulation of insulin secretion. Overall, our results suggest this new microplate assay will be a useful tool for many laboratories, expert or not in islet techniques, to be able to precisely quantify islet insulin secretion from their models of interest.

  13. Transformation of Lettuce with rol ABC Genes: Extracts Show Enhanced Antioxidant, Analgesic, Anti-Inflammatory, Antidepressant, and Anticoagulant Activities in Rats.

    PubMed

    Ismail, Hammad; Dilshad, Erum; Waheed, Mohammad Tahir; Mirza, Bushra

    2017-03-01

    Lettuce is an edible crop that is well known for dietary and antioxidant benefits. The present study was conducted to investigate the effects of rol ABC genes on antioxidant and medicinal potential of lettuce by Agrobacterium-mediated transformation. Transgene integration and expression was confirmed through PCR and real-time RT-PCR, respectively. The transformed plants showed 91-102 % increase in total phenolic contents and 53-65 % increase in total flavonoid contents compared to untransformed plants. Total antioxidant capacity and total reducing power increased up to 112 and 133 % in transformed plants, respectively. Results of DPPH assay showed maximum 51 % increase, and lipid peroxidation assay exhibited 20 % increase in antioxidant activity of transformed plants compared to controls. Different in vivo assays were carried out in rats. The transgenic plants showed up to 80 % inhibition in both hot plate analgesic assay and carrageenan-induced hind paw edema test, while untransformed plants showed only 45 % inhibition. Antidepressant and anticoagulant potential of transformed plants was also significantly enhanced compared to untransformed plants. Taken together, the present work highlights the use of rol genes to enhance the secondary metabolite production in lettuce and improve its analgesic, anti-inflammatory, antidepressant, and anticoagulatory properties.

  14. Lateral flow strip assay

    DOEpatents

    Miles, Robin R [Danville, CA; Benett, William J [Livermore, CA; Coleman, Matthew A [Oakland, CA; Pearson, Francesca S [Livermore, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2011-03-08

    A lateral flow strip assay apparatus comprising a housing; a lateral flow strip in the housing, the lateral flow strip having a receiving portion; a sample collection unit; and a reagent reservoir. Saliva and/or buccal cells are collected from an individual using the sample collection unit. The sample collection unit is immersed in the reagent reservoir. The tip of the lateral flow strip is immersed in the reservoir and the reagent/sample mixture wicks up into the lateral flow strip to perform the assay.

  15. Factor IX assay

    MedlinePlus

    ... factor assay; Serum factor IX; Hemophilic factor B; Plasma thromboplastin component; PTC ... BJ. Factor IX (Christmas factor, hemophilic factor B, plasma thromboplastin component, PTC) - blood. In: Chernecky CC, Berger ...

  16. Evaluation of cytotoxicity, genotoxicity and teratogenicity of marine sediments from Qingdao coastal areas using in vitro fish cell assay, comet assay and zebrafish embryo test.

    PubMed

    Yang, Fan; Zhang, Qianqian; Guo, Huarong; Zhang, Shicui

    2010-10-01

    Marine sediments are often a final sink for numerous anthropogenic contaminants and may impose serious effects on benthic organisms and ecosystem. An in vitro cell assay using a cell line derived from flounder gill (FG) cells, an in vitro comet assay in FG cells, and an in vitro zebrafish embryo assay were used to evaluate the in vitro cytotoxicity (measured by MTT reduction), genotoxicity and teratogenicity of crude sediment extracts of Li Cang (LC), Zhan Qiao (ZQ) and Olympic Sailing Center (OSC) from Qingdao coastal area. Sediments from the three sites displayed different cytotoxicity, genotoxicity and teratogenicity potencies; however, all three assays yielded similar LOECs (lowest observed effect concentration) for each site, suggesting that the assays were equally sensitive to and suitable for initial screening of the LOECs of marine sediments. The cytotoxicity, genotoxicity and teratogenicity for these three sampling sites were in the same order of LC>ZQ>OSC, indicating different degrees of contamination. Interestingly, trials with the three sediment extracts at the doses inducing a similar cytotoxicity as evaluated with MTT reduction did not produce similar genotoxicity and teratogenicity, with the genotoxic and teratogenic activities of LC and ZQ extracts being markedly higher than those of OSC sediments. These findings indicate that cytotoxicity does not form a fully equivalent toxicity index with that of genotoxicity and teratogenicity. Therefore, in order to assess the true toxic potential of marine sediments, all three assays should be performed. Analysis of 16 EPA (US Environmental Protection Agency) priority PAHs in these three sediment samples showed a clear correlation between PAH concentrations and sediment toxicities, with a higher PAH content corresponding to higher toxicity although PAHs are surely not the only cause. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Pharmacological profiling of the TRPV3 channel in recombinant and native assays

    PubMed Central

    Grubisha, Olivera; Mogg, Adrian J; Sorge, Jessica L; Ball, Laura-Jayne; Sanger, Helen; Ruble, Cara L A; Folly, Elizabeth A; Ursu, Daniel; Broad, Lisa M

    2014-01-01

    Background and Purpose Transient receptor potential vanilloid subtype 3 (TRPV3) is implicated in nociception and certain skin conditions. As such, it is an attractive target for pharmaceutical research. Understanding of endogenous TRPV3 function and pharmacology remains elusive as selective compounds and native preparations utilizing higher throughput methodologies are lacking. In this study, we developed medium-throughput recombinant and native cellular assays to assess the detailed pharmacological profile of human, rat and mouse TRPV3 channels. Experimental Approach Medium-throughput cellular assays were developed using a Ca2+-sensitive dye and a fluorescent imaging plate reader. Human and rat TRPV3 pharmacology was examined in recombinant cell lines, while the mouse 308 keratinocyte cell line was used to assess endogenous TRPV3 activity. Key Results A recombinant rat TRPV3 cellular assay was successfully developed after solving a discrepancy in the published rat TRPV3 protein sequence. A medium-throughput, native, mouse TRPV3 keratinocyte assay was also developed and confirmed using genetic approaches. Whereas the recombinant human and rat TRPV3 assays exhibited similar agonist and antagonist profiles, the native mouse assay showed important differences, namely, TRPV3 activity was detected only in the presence of potentiator or during agonist synergy. Furthermore, the native assay was more sensitive to block by some antagonists. Conclusions and Implications Our findings demonstrate similarities but also notable differences in TRPV3 pharmacology between recombinant and native systems. These findings offer insights into TRPV3 function and these assays should aid further research towards developing TRPV3 therapies. Linked Articles This article is part of a themed section on the pharmacology of TRP channels. To view the other articles in this section visit http://dx.doi.org/10.1111/bph.2014.171.issue-10 PMID:23848361

  18. Standardizing a simpler, more sensitive and accurate tail bleeding assay in mice

    PubMed Central

    Liu, Yang; Jennings, Nicole L; Dart, Anthony M; Du, Xiao-Jun

    2012-01-01

    AIM: To optimize the experimental protocols for a simple, sensitive and accurate bleeding assay. METHODS: Bleeding assay was performed in mice by tail tip amputation, immersing the tail in saline at 37 °C, continuously monitoring bleeding patterns and measuring bleeding volume from changes in the body weight. Sensitivity and extent of variation of bleeding time and bleeding volume were compared in mice treated with the P2Y receptor inhibitor prasugrel at various doses or in mice deficient of FcRγ, a signaling protein of the glycoprotein VI receptor. RESULTS: We described details of the bleeding assay with the aim of standardizing this commonly used assay. The bleeding assay detailed here was simple to operate and permitted continuous monitoring of bleeding pattern and detection of re-bleeding. We also reported a simple and accurate way of quantifying bleeding volume from changes in the body weight, which correlated well with chemical assay of hemoglobin levels (r2 = 0.990, P < 0.0001). We determined by tail bleeding assay the dose-effect relation of the anti-platelet drug prasugrel from 0.015 to 5 mg/kg. Our results showed that the correlation of bleeding time and volume was unsatisfactory and that compared with the bleeding time, bleeding volume was more sensitive in detecting a partial inhibition of platelet’s haemostatic activity (P < 0.01). Similarly, in mice with genetic disruption of FcRγ as a signaling molecule of P-selectin glycoprotein ligand-1 leading to platelet dysfunction, both increased bleeding volume and repeated bleeding pattern defined the phenotype of the knockout mice better than that of a prolonged bleeding time. CONCLUSION: Determination of bleeding pattern and bleeding volume, in addition to bleeding time, improved the sensitivity and accuracy of this assay, particularly when platelet function is partially inhibited. PMID:24520531

  19. 21 CFR 864.7455 - Fetal hemoglobin assay.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal hemoglobin assay. 864.7455 Section 864.7455...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7455 Fetal hemoglobin assay. (a) Identification. A fetal hemoglobin assay is a device that is used to determine the presence...

  20. 21 CFR 864.7455 - Fetal hemoglobin assay.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal hemoglobin assay. 864.7455 Section 864.7455...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7455 Fetal hemoglobin assay. (a) Identification. A fetal hemoglobin assay is a device that is used to determine the presence...