Patel, Nitesh V; Sundararajan, Sri; Keller, Irwin; Danish, Shabbar
2018-01-01
Objective: Magnetic resonance (MR)-guided stereotactic laser amygdalohippocampectomy is a minimally invasive procedure for the treatment of refractory epilepsy in patients with mesial temporal sclerosis. Limited data exist on post-ablation volumetric trends associated with the procedure. Methods: 10 patients with mesial temporal sclerosis underwent MR-guided stereotactic laser amygdalohippocampectomy. Three independent raters computed ablation volumes at the following time points: pre-ablation (PreA), immediate post-ablation (IPA), 24 hours post-ablation (24PA), first follow-up post-ablation (FPA), and greater than three months follow-up post-ablation (>3MPA), using OsiriX DICOM Viewer (Pixmeo, Bernex, Switzerland). Statistical trends in post-ablation volumes were determined for the time points. Results: MR-guided stereotactic laser amygdalohippocampectomy produces a rapid rise and distinct peak in post-ablation volume immediately following the procedure. IPA volumes are significantly higher than all other time points. Comparing individual time points within each raters dataset (intra-rater), a significant difference was seen between the IPA time point and all others. There was no statistical difference between the 24PA, FPA, and >3MPA time points. A correlation analysis demonstrated the strongest correlations at the 24PA (r=0.97), FPA (r=0.95), and 3MPA time points (r=0.99), with a weaker correlation at IPA (r=0.92). Conclusion: MR-guided stereotactic laser amygdalohippocampectomy produces a maximal increase in post-ablation volume immediately following the procedure, which decreases and stabilizes at 24 hours post-procedure and beyond three months follow-up. Based on the correlation analysis, the lower inter-rater reliability at the IPA time point suggests it may be less accurate to assess volume at this time point. We recommend post-ablation volume assessments be made at least 24 hours post-selective ablation of the amygdalohippocampal complex (SLAH).
Li, Yuqian; Yang, Ruixin; Li, Zhihong; Yang, Yanping; Tian, Bo; Zhang, Xingye; Wang, Bao; Lu, Dan; Guo, Shaochun; Man, Minghao; Yang, Yang; Luo, Tao; Gao, Guodong; Li, Lihong
2017-09-01
The safety and efficacy of craniotomy, endoscopic surgery, and stereotactic aspiration for surgical evacuation of spontaneous supratentorial lobar intracerebral hemorrhage (ICH) is yet uncertain. The present study analyzed the clinical and radiographic data from 99 patients with spontaneous supratentorial lobar ICH, retrospectively, to address this issue. Patients who underwent craniotomy, endoscopy surgery, or stereotactic aspiration were assigned to the craniotomy group (n = 31), endoscopy surgery group (n = 32), or stereotactic aspiration group (n = 36), respectively. The characteristics of all the enrolled patients at the time of admission were assimilated. Also, the therapeutic effects of the three surgical procedures were evaluated based on short-term outcomes within 30 days and long-term outcomes at 6 months after the ictus. The results showed that stereotactic aspiration and endoscopic surgery were associated with a superior clinical therapeutic effect in both short-term and long-term outcomes than craniotomy for the treatment of spontaneous supratentorial lobar ICH. Notably, severely affected patients with hematoma volume > 60 mL or Glasgow Coma Scale score 4-8 may benefit more from endoscopic surgery than the two other surgical procedures. The current findings demonstrate that both stereotactic aspiration and endoscopic surgery possess an apparent advantage over craniotomy for the evacuation of spontaneous supratentorial lobar ICH. The endoscopic surgery might be more safe and effective with higher evacuation rate, better functional neurological outcomes, and lower complication and mortality rates. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kondziolka, D.; Lunsford, L.D.; Coffey, R.J.
1990-12-01
Stereotactic radiosurgery has been shown to treat successfully angiographically demonstrated arteriovenous malformations of the brain. Angiographic obliteration has represented cure and eliminated the risk of future hemorrhage. The role of radiosurgery in the treatment of angiographically occult vascular malformations (AOVMs) has been less well defined. In the initial 32 months of operation of the 201-source cobalt-60 gamma knife at the University of Pittsburgh, 24 patients meeting strict criteria for high-risk AOVMs were treated. Radiosurgery was used conservatively; each patient had sustained two or more hemorrhages and had a magnetic resonance imaging-defined AOVM located in a region of the brain wheremore » microsurgical removal was judged to pose an excessive risk. Venous angiomas were excluded by performance of high-resolution subtraction angiography in each patient. Fifteen malformations were in the medulla, pons, and/or mesencephalon, and 5 were located in the thalamus or basal ganglia. Follow-up ranged from 4 to 24 months. Nineteen patients either improved or remained clinically stable and did not hemorrhage again during the follow-up interval. One patient suffered another hemorrhage 7 months after radiosurgery. Five patients experienced temporary worsening of pre-existing neurological deficits that suggested delayed radiation injury. Magnetic resonance imaging demonstrated signal changes and edema surrounding the radiosurgical target. Dose-volume guidelines for avoiding complications were constructed. Our initial experience indicates that stereotactic radiosurgery can be performed safely in patients with small, well-circumscribed AOVMs located in deep, critical, or relatively inaccessible cerebral locations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Xin; Liu Xiaoxia; Mei Guanghai
Purpose: Cavernous sinus hemangioma is a rare vascular tumor. The direct microsurgical approach usually results in massive hemorrhage. Although radiosurgery plays an important role in managing cavernous sinus hemangiomas as a treatment alternative to microsurgery, the potential for increased toxicity with single-session treatment of large tumors is a concern. The purpose of this study was to assess the efficacy of hypofractionated stereotactic radiotherapy in patients with large cavernous sinus hemangiomas. Methods: Fourteen patients with large (volume >20 cm{sup 3}) cavernous sinus hemangiomas were enrolled in a prospective Phase II study between December 2007 and December 2010. The hypofractionated stereotactic radiotherapymore » dose was 21 Gy delivered in 3 fractions. Results: After a mean follow-up of 15 months (range, 6-36 months), the magnetic resonance images showed a mean of 77% tumor volume reduction (range, 44-99%). Among the 6 patients with cranial nerve impairments before hypofractionated stereotactic radiotherapy, 1 achieved symptomatic complete resolution and 5 had improvement. No radiotherapy-related complications were observed during follow-up. Conclusion: Our current experience, though preliminary, substantiates the role of hypofractionated stereotactic radiotherapy for large cavernous sinus hemangiomas. Although a longer and more extensive follow-up is needed, hypofractionated stereotactic radiotherapy of 21 Gy delivered in 3 fractions is effective in reducing the tumor volume without causing any new deficits and can be considered as a treatment modality for large cavernous sinus hemangiomas.« less
Stereotactic radiosurgery for the treatment of symptomatic brainstem cavernous malformations.
Monaco, Edward A; Khan, Aftab A; Niranjan, Ajay; Kano, Hideyuki; Grandhi, Ramesh; Kondziolka, Douglas; Flickinger, John C; Lunsford, L Dade
2010-09-01
The authors performed a retrospective review of prospectively collected data to evaluate the safety and efficacy of stereotactic radiosurgery (SRS) for the treatment of patients harboring symptomatic solitary cavernous malformations (CMs) of the brainstem that bleed repeatedly and are high risk for resection. Between 1988 and 2005, 68 patients (34 males and 34 females) with solitary, symptomatic CMs of the brainstem underwent Gamma Knife surgery. The mean patient age was 41.2 years, and all patients had suffered at least 2 symptomatic hemorrhages (range 2-12 events) before radiosurgery. Prior to SRS, 15 patients (22.1%) had undergone attempted resection. The mean volume of the malformation treated was 1.19 ml, and the mean prescribed marginal radiation dose was 16 Gy. The mean follow-up period was 5.2 years (range 0.6-12.4 years). The pre-SRS annual hemorrhage rate was 32.38%, or 125 hemorrhages, excluding the first hemorrhage, over a total of 386 patient-years. Following SRS, 11 hemorrhages were observed within the first 2 years of follow-up (8.22% annual hemorrhage rate) and 3 hemorrhages were observed in the period after the first 2 years of follow-up (1.37% annual hemorrhage rate). A significant reduction (p < 0.0001) in the risk of brainstem CM hemorrhages was observed following radiosurgical treatment, as well as in latency period of 2 years after SRS (p < 0.0447). Eight patients (11.8%) experienced new neurological deficits as a result of adverse radiation effects following SRS. The results of this study support a role for the use of SRS for symptomatic CMs of the brainstem, as it is relatively safe and appears to reduce rebleeding rates in this high-surgical-risk location.
NASA Robotic Neurosurgery Testbed
NASA Technical Reports Server (NTRS)
Mah, Robert
1997-01-01
The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations, In neurosurgery, the needle used in the standard stereotactic CT or MRI guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled "Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification" is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.
NASA Robotic Neurosurgery Testbed
NASA Technical Reports Server (NTRS)
Mah, Robert
1997-01-01
The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations. In neurosurgery, the needle used in the standard stereotactic CT (Computational Tomography) or MRI (Magnetic Resonance Imaging) guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled 'Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification' is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.
Robotic Stereotaxy in Cranial Neurosurgery: A Qualitative Systematic Review.
Fomenko, Anton; Serletis, Demitre
2017-12-14
Modern-day stereotactic techniques have evolved to tackle the neurosurgical challenge of accurately and reproducibly accessing specific brain targets. Neurosurgical advances have been made in synergy with sophisticated technological developments and engineering innovations such as automated robotic platforms. Robotic systems offer a unique combination of dexterity, durability, indefatigability, and precision. To perform a systematic review of robotic integration for cranial stereotactic guidance in neurosurgery. Specifically, we comprehensively analyze the strengths and weaknesses of a spectrum of robotic technologies, past and present, including details pertaining to each system's kinematic specifications and targeting accuracy profiles. Eligible articles on human clinical applications of cranial robotic-guided stereotactic systems between 1985 and 2017 were extracted from several electronic databases, with a focus on stereotactic biopsy procedures, stereoelectroencephalography, and deep brain stimulation electrode insertion. Cranial robotic stereotactic systems feature serial or parallel architectures with 4 to 7 degrees of freedom, and frame-based or frameless registration. Indications for robotic assistance are diversifying, and include stereotactic biopsy, deep brain stimulation and stereoelectroencephalography electrode placement, ventriculostomy, and ablation procedures. Complication rates are low, and mainly consist of hemorrhage. Newer systems benefit from increasing targeting accuracy, intraoperative imaging ability, improved safety profiles, and reduced operating times. We highlight emerging future directions pertaining to the integration of robotic technologies into future neurosurgical procedures. Notably, a trend toward miniaturization, cost-effectiveness, frameless registration, and increasing safety and accuracy characterize successful stereotactic robotic technologies. Copyright © 2017 by the Congress of Neurological Surgeons
Target coverage in image-guided stereotactic body radiotherapy of liver tumors.
Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M
2007-05-01
To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hattangadi, Jona A.; Chapman, Paul H.; Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA
2012-06-01
Purpose: To evaluate patients with high-risk cerebral arteriovenous malformations (AVMs), based on eloquent brain location or large size, who underwent planned two-fraction proton stereotactic radiosurgery (PSRS). Methods and Materials: From 1991 to 2009, 59 patients with high-risk cerebral AVMs received two-fraction PSRS. Median nidus volume was 23 cc (range, 1.4-58.1 cc), 70% of cases had nidus volume {>=}14 cc, and 34% were in critical locations (brainstem, basal ganglia). Median AVM score based on age, AVM size, and location was 3.19 (range, 0.9-6.9). Many patients had prior surgery or embolization (40%) or prior PSRS (12%). The most common prescription was 16more » Gy radiobiologic equivalent (RBE) in two fractions, prescribed to the 90% isodose. Results: At a median follow-up of 56.1 months, 9 patients (15%) had total and 20 patients (34%) had partial obliteration. Patients with total obliteration received higher total dose than those with partial or no obliteration (mean dose, 17.6 vs. 15.5 Gy (RBE), p = 0.01). Median time to total obliteration was 62 months (range, 23-109 months), and 5-year actuarial rate of partial or total obliteration was 33%. Five-year actuarial rate of hemorrhage was 22% (95% confidence interval, 12.5%-36.8%) and 14% (n = 8) suffered fatal hemorrhage. Lesions with higher AVM scores were more likely to hemorrhage (p = 0.024) and less responsive to radiation (p = 0.026). The most common complication was Grade 1 headache acutely (14%) and long term (12%). One patient developed a Grade 2 generalized seizure disorder, and two had mild neurologic deficits. Conclusions: High-risk AVMs can be safely treated with two-fraction PSRS, although total obliteration rate is low and patients remain at risk for future hemorrhage. Future studies should include higher doses or a multistaged PSRS approach for lesions more resistant to obliteration with radiation.« less
McCracken, D. Jay; Willie, Jon T.; Fernald, Brad; Saindane, Amit M.; Drane, Daniel L.; Barrow, Daniel L.; Gross, Robert E.
2016-01-01
BACKGROUND Surgery is indicated for cerebral cavernous malformations (CCM) that cause medically refractory epilepsy. Real-time magnetic resonance thermography (MRT)-guided stereotactic laser ablation (SLA) is a minimally invasive approach to treating focal brain lesions. SLA of CCM has not previously been described. OBJECTIVE To describe MRT-guided SLA, a novel approach to treating CCM-related epilepsy, with respect to feasibility, safety, imaging, and seizure control in 5 consecutive patients. METHODS Five patients with medically refractory epilepsy undergoing standard presurgical evaluation were found to have corresponding lesions fulfilling imaging characteristics of CCM and were prospectively enrolled. Each underwent stereotactic placement of a saline-cooled cannula containing an optical fiber to deliver 980-nm diode laser energy via twist drill craniostomy. MR anatomic imaging was used to evaluate targeting prior to ablation. MR imaging provided evaluation of targeting and near real-time feedback regarding extent of tissue thermocoagulation. Patients maintained seizure diaries, and remote imaging (6–21 months post-ablation) was obtained in all patients. RESULTS Imaging revealed no evidence of acute hemorrhage following fiber placement within presumed CCM. MRT during treatment and immediate post-procedure imaging confirmed desired extent of ablation. We identified no adverse events or neurological deficits. Four of 5 (80%) patients achieved freedom from disabling seizures after SLA alone (Engel class 1 outcome), with follow-up ranging 12–28 months. Reimaging of all subjects (6–21 months) indicated lesion diminution with surrounding liquefactive necrosis, consistent with the surgical goal of extended lesionotomy. CONCLUSION Minimally invasive MRT-guided SLA of epileptogenic CCM is a potentially safe and effective alternative to open resection. Additional experience and longer follow-up are needed. PMID:27959970
Giuliani, Meredith; Mathew, Ashwathy S; Bahig, Houda; Bratman, Scott V; Filion, Edith; Glick, Daniel; Louie, Alexander V; Raman, Srinivas; Swaminath, Anand; Warner, Andrew; Yau, Vivian; Palma, David
2018-04-18
Lung stereotactic body radiotherapy (SBRT) is considered a standard curative treatment for medically inoperable early stage non-small-cell lung cancer (NSCLC). Patients with ultracentral tumors (signifying tumors whose planning target volume touches or overlaps the central bronchial tree, esophagus, or pulmonary artery) may be at higher risk of serious toxicities such as bronchial stricture and collapse, esophageal strictures, tracheal-esophageal fistula, and hemorrhage. The primary objective of the study is to determine the maximum tolerated dose of radiotherapy for ultracentral NSCLC. This multicenter phase 1 dose-escalation study will use a time-to-event continual reassessment method (TITE-CRM). Accrual will start at level 1 (60 Gy in 8 fractions delivered daily). The model will use all available information from previously accrued patients to assign the highest dose with a predicted risk of grade 3-5 toxicity of 30% or less. All patients with newly diagnosed stage T1-3 N0M0 NSCLC (International Union Against Cancer, 8th edition) with tumor size ≤ 6 cm and meeting the criteria for ultracentral location (ie, tumors whose planning target volume touches or overlaps the central bronchial tree, esophagus, pulmonary vein, or pulmonary artery) will be eligible for this study. It is important to identify a safe dose-fractionation regimen for treating ultracentral tumors with SBRT. In addition, the data from this study may be informative in guiding future studies on the use of SBRT in treating malignancies within the mediastinum-for example, for salvage treatment of mediastinal lymph nodes for recurrent NSCLC or mediastinal oligometastases. Copyright © 2018 Elsevier Inc. All rights reserved.
Yamada, Yoshiya; Lovelock, D Michael; Yenice, Kamil M; Bilsky, Mark H; Hunt, Margaret A; Zatcky, Joan; Leibel, Steven A
2005-05-01
The use of image-guided and stereotactic intensity-modulated radiotherapy (IMRT) techniques have made the delivery of high-dose radiation to lesions within close proximity to the spinal cord feasible. This report presents clinical and physical data regarding the use of IMRT coupled with noninvasive body frames (stereotactic and image-guided) for multifractionated radiotherapy. The Memorial Sloan-Kettering Cancer Center (Memorial) stereotactic body frame (MSBF) and Memorial body cradle (MBC) have been developed as noninvasive immobilizing devices for paraspinal IMRT using stereotactic (MSBF) and image-guided (MBC) techniques. Patients were either previously irradiated or prescribed doses beyond spinal cord tolerance (54 Gy in standard fractionation) and had unresectable gross disease involving the spinal canal. The planning target volume (PTV) was the gross tumor volume with a 1 cm margin. The PTV was not allowed to include the spinal cord contour. All treatment planning was performed using software developed within the institution. Isocenter verification was performed with an in-room computed tomography scan (MSBF) or electronic portal imaging devices, or both. Patients were followed up with serial magnetic resonance imaging every 3-4 months, and no patients were lost to follow-up. Kaplan-Meier statistics were used for analysis of clinical data. Both the MSBF and MBC were able to provide setup accuracy within 2 mm. With a median follow-up of 11 months, 35 patients (14 primary and 21 secondary malignancies) underwent treatment. The median dose previously received was 3000 cGy in 10 fractions. The median dose prescribed for these patients was 2000 cGy/5 fractions (2000-3000 cGy), which provided a median PTV V100 of 88%. In previously unirradiated patients, the median prescribed dose was 7000 cGy (5940-7000 cGy) with a median PTV V100 of 90%. The median Dmax to the cord was 34% and 68% for previously irradiated and never irradiated patients, respectively. More than 90% of patients experienced palliation from pain, weakness, or paresthesia; 75% and 81% of secondary and primary lesions, respectively, exhibited local control at the time of last follow-up. No cases of radiation-induced myelopathy or radiculopathy have thus far been encountered. Precision stereotactic and image-guided paraspinal IMRT allows the delivery of high doses of radiation in multiple fractions to tumors within close proximity to the spinal cord while respecting cord tolerance. Although preliminary, the clinical results are encouraging.
Kim, Sang Heum; Kong, Min Ho
2017-01-01
Objective Aneurysm clipping and simultaneous hematoma evacuation through open craniotomy is traditionally recommended for ruptured cerebral aneurysms accompanied by intracerebral or intrasylvian hemorrhages. We report our experience of adapting a less invasive treatment strategy in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms, where the associated ruptured cerebral aneurysms were managed by endovascular coil embolization, followed by stereotactic aspiration of hematomas (SRH) using urokinase. Materials and Methods We retrospectively analyzed 112 patients with ruptured cerebral aneurysms. There were accompanying intracerebral or intrasylvian hemorrhages in 36 patients (32.1%). The most common site for these ruptured aneurysms was the middle cerebral artery (MCA) (n = 15; 41.6%). Endovascular coil embolization followed by SRH using urokinase was performed in 9 patients (25%). Results In these 9 patients, the most common site of aneurysms was the MCA (n = 3; 33.4%); the hematoma volume ranged from 19.24 to 61.68 mL. Four patients who were World Federation of Neurological Surgeons (WFNS) grade-IV on admission, achieved favorable outcomes (Glasgow Outcome Score [GOS] 4 or 5) at 6-months postoperatively. In the five patients who were WFNS grade-V on admission, one achieved a favorable outcome, whereas 4 achieved GOS scores of 2 or 3, 6-months postoperatively. There was no mortality. Conclusion If immediate hematoma evacuation is not mandated by clinical or radiological signs of brain herniation, a less invasive strategy, such as endovascular coil embolization followed by SRH using urokinase, may be a good alternative in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms. PMID:29152466
Willie, Jon T.; Laxpati, Nealen G.; Drane, Daniel L.; Gowda, Ashok; Appin, Christina; Hao, Chunhai; Brat, Daniel J.; Helmers, Sandra L.; Saindane, Amit; Nour, Sherif G.; Gross, Robert E.
2014-01-01
Background Open surgery effectively treats mesial temporal lobe epilepsy (MTLE), but carries risks of neurocognitive deficits, which may be reduced with minimally invasive alternatives. Objective To describe technical and clinical outcomes of stereotactic laser amygdalohippocampotomy (SLAH) with real-time magnetic resonance thermal imaging (MRTI) guidance. Methods Under general anesthesia and utilizing standard stereotactic methods, 13 adult patients with intractable MTLE (with and without mesial temporal sclerosis, MTS) prospectively underwent insertion of a saline-cooled fiber-optic laser applicator into amygdalohippocampal structures from an occipital trajectory. Computer-controlled laser ablation was performed during continuous MRTI followed by confirmatory contrast-enhanced anatomic imaging and volumetric reconstruction. Clinical outcomes were determined from seizure diaries. Results A mean 60% volume of the amygdalohippocampal complex was ablated in 13 patients (9 with MTS) undergoing 15 procedures. Median hospitalization was one day. With follow-up ranging from 5-26 (median 14) months, 77% (10/13) of patients achieved meaningful seizure reduction, of which 54% (7/13) were free of disabling seizures. Of patients with preoperative MTS, 67% (6/9) achieved seizure freedom. All recurrences were observed by<6 months. Variances in ablation volume and length did not account for individual clinical outcomes. Whereas no complications of laser therapy itself were observed, one significant complication, a visual field defect, resulted from deviated insertion of a stereotactic aligning rod, which was corrected prior to ablation. Conclusion Real-time MR-guided SLAH is a technically novel, safe, and effective alternative to open surgery. Further evaluation with larger cohorts over time is warranted. PMID:24618797
Single-Fraction Proton Beam Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hattangadi-Gluth, Jona A.; Chapman, Paul H.; Kim, Daniel
2014-06-01
Purpose/Objective(s): To evaluate the obliteration rate and potential adverse effects of single-fraction proton beam stereotactic radiosurgery (PSRS) in patients with cerebral arteriovenous malformations (AVMs). Methods and Materials: From 1991 to 2010, 248 consecutive patients with 254 cerebral AVMs received single-fraction PSRS at our institution. The median AVM nidus volume was 3.5 cc (range, 0.1-28.1 cc), 23% of AVMs were in critical/deep locations (basal ganglia, thalamus, or brainstem), and the most common prescription dose was 15 Gy(relative biological effectiveness [RBE]). Univariable and multivariable analyses were performed to assess factors associated with obliteration and hemorrhage. Results: At a median follow-up time of 35 months (range, 6-198 months),more » 64.6% of AVMs were obliterated. The median time to total obliteration was 31 months (range, 6-127 months), and the 5-year and 10-year cumulative incidence of total obliteration was 70% and 91%, respectively. On univariable analysis, smaller target volume (hazard ratio [HR] 0.78, 95% confidence interval [CI] 0.86-0.93, P<.0001), smaller treatment volume (HR 0.93, 95% CI 0.90-0.96, P<.0001), higher prescription dose (HR 1.16, 95% CI 1.07-1.26, P=.001), and higher maximum dose (HR 1.14, 95% CI 1.05-1.23, P=.002) were associated with total obliteration. Deep/critical location was also associated with decreased likelihood of obliteration (HR 0.68, 95% CI 0.47-0.98, P=.04). On multivariable analysis, critical location (adjusted HR [AHR] 0.42, 95% CI 0.27-0.65, P<.001) and smaller target volume (AHR 0.81, 95% CI 0.68-0.97, P=.02) remained associated with total obliteration. Posttreatment hemorrhage occurred in 13 cases (5-year cumulative incidence of 7%), all among patients with less than total obliteration, and 3 of these events were fatal. The most common complication was seizure, controlled with medications, both acutely (8%) and in the long term (9.1%). Conclusions: The current series is the largest modern series of PSRS for cerebral AVMs. PSRS can achieve a high obliteration rate with minimal morbidity. Post-treatment hemorrhage remains a potentially fatal risk among patients who have not yet responded to treatment.« less
Brown, William T; Wu, Xiaodong; Amendola, Beatriz; Perman, Mark; Han, Hoke; Fayad, Fahed; Garcia, Silvio; Lewin, Alan; Abitbol, Andre; de la Zerda, Alberto; Schwade, James G
2007-01-01
To evaluate the efficacy of using image-guided robotic stereotactic radioablation as an alternative treatment modality for patients with surgically resectable, but medically inoperable, T1 N0 M0, stage IA non-small cell lung cancer. Between January 2004 and May 2006, 19 patients, 11 women and 8 men ranging in age from 52 to 88 years, with stage IA non-small cell lung cancer were treated. Tumor volume ranged from 1.7 to 13 mL. Total doses ranged from 24 to 60 Gy delivered in 3 fractions. Eleven patients received 60 Gy. Real-time target localization was accomplished by radiographic detection of fiducial marker(s) implanted within the tumor combined with respiratory motion tracking. All patients tolerated radioablation well with fatigue as the main side effect. Fourteen patients are alive from 1 to 25 months posttreatment. Four patients died: 2 of comorbid disease and 2 of cancer progression (status post 60 and 55.5 Gy). Three patients developed grade I radiation pneumonitis. Two patients have stable disease. In 3 patients, cancer recurred in the planning treatment volume: in 2 patients after treatment with 60 Gy and in 1 patient after treatment with 55.5 Gy. One patient had local control in the target volume but developed metastasis to the ipsilateral hilum. Nine patients had a complete response and show no evidence of disease. In our early experience, stereotactic radioablation using the CyberKnife system appears to be a safe, minimally invasive, and effective modality for treating early stage lung cancer in patients with medically inoperable disease. Dose escalation and/or increasing the treatment volumes, with the aid of the high conformality of this technique, may help to achieve further improvements in these promising results.
Boyum, James H; Atwell, Thomas D; Wall, Darci J; Mansfield, Aaron S; Kerr, Sarah E; Gunderson, Tina M; Rumilla, Kandelaria M; Weisbrod, Adam J; Kurup, A Nicholas
2018-05-17
To analyze a large volume of image-guided liver mass biopsies to assess for an increased incidence of major hemorrhage after aggressive liver mass sampling, and to determine if coaxial technique reduces major hemorrhage rate. Patients who underwent image-guided liver mass biopsy over a 15-year period (December 7, 2001-September 22, 2016) were retrospectively identified. An aggressive biopsy was defined as a biopsy event in which ≥ 4 core needle passes were performed. Association of major hemorrhage after aggressive liver mass biopsy and other potential risk factors of interest were assessed using logistic regression analysis. For the subset of aggressive biopsies, Fisher's exact test was used to compare the incidence of major hemorrhage using coaxial versus noncoaxial techniques. Aggressive biopsies constituted 11.6% of biopsy events (N =579/5011). The incidence of major hemorrhage with <4 passes was 0.4% (N =18/4432) and with ≥4 passes 1.2% (N =6/579). In univariable models, aggressive biopsy was significantly associated with major hemorrhage (OR 3.0, 95% CI 1.16-6.92, p =0.025). After adjusting for gender and platelet count, the association was not significant at the p =0.05 level (OR 2.58, 95% CI 0.927-6.24, p =0.067). The rate of major hemorrhage in the coaxial biopsy technique group was 1.4% (N =3/209) compared to 1.1% (N =4/370) in the noncoaxial biopsy technique group, which was not a significant difference (p =0.707). Although aggressive image-guided liver mass biopsies had an increased incidence of major hemorrhage, the overall risk of bleeding remained low. The benefit of such biopsies will almost certainly outweigh the risk in most patients.
Heinz, Christian; Gerum, Sabine; Freislederer, Philipp; Ganswindt, Ute; Roeder, Falk; Corradini, Stefanie; Belka, Claus; Niyazi, Maximilian
2016-06-27
Fiducial markers are the superior method to compensate for interfractional motion in liver SBRT. However this method is invasive and thereby limits its application range. In this retrospective study, the compensation method for the interfractional motion using fiducial markers (gold standard) was compared to a new non-invasive approach, which does rely on the organ motion of the liver and the relative tumor position within this volume. We analyzed six patients (3 m, 3f) treated with SBRT in 2014. After fiducial marker implantation, all patients received a treatment CT (free breathing, without abdominal compression) and a 4D-CT (consisting of 10 respiratory phases). For all patients the gross tumor volumes (GTVs), internal target volume (ITV), planning target volume (PTV), internal marker target volumes (IMTVs) and the internal liver target volume (ILTV) were delineated based on the CT and 4D-CT images. CBCT imaging was used for the standard treatment setup based on the fiducial markers. According to the patient coordinates the 3 translational compensation values (t x , t y , t z ) for the interfractional motion were calculated by matching the blurred fiducial markers with the corresponding IMTV structures. 4 observers were requested to recalculate the translational compensation values for each CBCT (31) based on the ILTV structures. The differences of the translational compensation values between the IMTV and ILTV approach were analyzed. The magnitude of the mean absolute 3D registration error with regard to the gold standard overall patients and observers was 0.50 cm ± 0.28 cm. Individual registration errors up to 1.3 cm were observed. There was no significant overall linear correlation between the respiratory motion and the registration error of the ILTV approach. Two different methods to calculate the translational compensation values for interfractional motion in stereotactic liver therapy were evaluated. The registration accuracy of the ILTV approach is mainly limited by the non-rigid behavior of the liver and the individual registration experience of the observer. The ILTV approach lacks the accuracy that would be desired for stereotactic radiotherapy of the liver.
Integration of stereotactic ultrasonic data into an interactive image-guided neurosurgical system
NASA Astrophysics Data System (ADS)
Shima, Daniel W.; Galloway, Robert L., Jr.
1998-06-01
Stereotactic ultrasound can be incorporated into an interactive, image-guide neurosurgical system by using an optical position sensor to define the location of an intraoperative scanner in physical space. A C-program has been developed that communicates with the OptotrakTM system developed by Northern Digital Inc. to optically track the three-dimensional position and orientation of a fan-shaped area defined with respect to a hand-held probe. (i.e., a virtual B-mode ultrasound fan beam) Volumes of CT and MR head scans from the same patient are registered to a location in physical space using a point-based technique. The coordinates of the virtual fan beam in physical space are continuously calculated and updated on-the-fly. During each program loop, the CT and MR data volumes are reformatted along the same plane and displayed as two fan-shaped images that correspond to the current physical-space location of the virtual fan beam. When the reformatted preoperative tomographic images are eventually paired with a real-time intraoperative ultrasound image, a neurosurgeon will be able to use the unique information of each imaging modality (e.g., the high resolution and tissue contrast of CT and MR and the real-time functionality of ultrasound) in a complementary manner to identify structures in the brain more easily and to guide surgical procedures more effectively.
A multinational report of technical factors on stereotactic body radiotherapy for oligometastases.
Redmond, Kristin J; Lo, Simon S; Dagan, Roi; Poon, Ian; Foote, Matthew C; Erler, Darby; Lee, Young; Lohr, Frank; Biswas, Tithi; Ricardi, Umberto; Sahgal, Arjun
2017-05-01
Oligometastatic cancer is being increasingly managed with aggressive local therapy using stereotactic body radiation therapy (SBRT). However, few guidelines exist. We summarize the results of an international survey reviewing technical factors for extracranial SBRT for oligometastatic disease to guide safe management. Seven high-volume centers contributed. Levels of agreement were categorized as strong (6-7 common responses), moderate (4-5), low (2-3) or no agreement. We present the results of a multi-national and multi-institutional survey of technical factors of SBRT for extracranial oligometastases. Key methods including target delineation, prescription doses, normal tissue constraints, imaging and set-up for safe implementation and practice of SBRT for oligometastasis have been identified. This manuscript will serve as a foundation for future clinical evaluations.
Lanotte, M; Cavallo, M; Franzini, A; Grifi, M; Marchese, E; Pantaleoni, M; Piacentino, M; Servello, D
2010-09-01
Deep brain stimulation (DBS) alleviates symptoms of many neurological disorders by applying electrical impulses to the brain by means of implanted electrodes, generally put in place using a conventional stereotactic frame. A new image guided disposable mini-stereotactic system has been designed to help shorten and simplify DBS procedures when compared to standard stereotaxy. A small number of studies have been conducted which demonstrate localization accuracies of the system similar to those achievable by the conventional frame. However no data are available to date on the economic impact of this new frame. The aim of this paper was to develop a computational model to evaluate the investment required to introduce the image guided mini-stereotactic technology for stereotactic DBS neurosurgery. A standard DBS patient care pathway was developed and related costs were analyzed. A differential analysis was conducted to capture the impact of introducing the image guided system on the procedure workflow. The analysis was carried out in five Italian neurosurgical centers. A computational model was developed to estimate upfront investments and surgery costs leading to a definition of the best financial option to introduce the new frame. Investments may vary from Euro 1.900 (purchasing of Image Guided [IG] mini-stereotactic frame only) to Euro 158.000.000. Moreover the model demonstrates how the introduction of the IG mini-stereotactic frame doesn't substantially affect the DBS procedure costs.
Zhu, Yan; Deng, Li; Tang, Huajun; Gao, Xiaoqing; Wang, Youhua; Guo, Kan; Kong, Jiming; Yang, Chaoxian
2017-05-01
Acupuncture has been widely used as a treatment for stroke in China for a long time. Recently, studies have demonstrated that electroacupuncture (EA) can accelerate intracerebral hemorrhage (ICH)-induced angiogenesis in rats. In the present study, we investigated the effect of EA on neurobehavioral function and brain injury in ICH rats. ICH was induced by stereotactic injection of collagenase type I and heparin into the right caudate putamen. Adult ICH rats were randomly divided into the following three groups: model control group (MC), EA at non-acupoint points group (non-acupoint EA) and EA at Baihui and Dazhui acupoints group (EA). The neurobehavioral deficits of ICH rats were assessed by modified neurological severity score (mNSS) and gait analysis. The hemorrhage volume and glucose metabolism of hemorrhagic foci were detected by PET/CT. The expression levels of MBP, NSE and S100-B proteins in serum were tested by ELISA. The histopathological features were examined by haematoxylin-eosin (H&E) staining. Apoptosis-associated proteins in the perihematomal region were observed by immunohistochemistry. EA treatment significantly promoted the recovery of neurobehavioral function in ICH rats. Hemorrhage volume reduced in EA group at day 14 when compared with MC and non-acupoint EA groups. ELISA showed that the levels of MBP, NSE and S100-B in serum were all down-regulated by EA treatment. The brain tissue of ICH rat in the EA group was more intact and compact than that in the MC and non-acupoint groups. In the perihematomal regions, the expression of Bcl-2 protein increased and expressions of Caspase-3 and Bax proteins decreased in the EA group vs MC and non-acupoint EA groups. Our data suggest that EA treatment can improve neurobehavioral function and brain injury, which were likely connected with the absorption of hematoma and regulation of apoptosis-related proteins. Copyright © 2017 Elsevier Inc. All rights reserved.
Fiorella, David; Arthur, Adam; Schafer, Sebastian
2015-08-01
The Apollo system (Penumbra Inc, Alameda, California, USA) is a low profile irrigation-aspiration system designed for the evacuation of intracranial hemorrhage. To demonstrate the feasibility of using Apollo in combination with cone beam CT guidance. Parenchymal (n=1) and mixed parenchymal-intraventricular hematomas (n=1) were created in cadaver heads using a transvascular (n=1) or transcranial (n=1) approach. Hematomas were then imaged with cone beam CT (CB-CT), and the long axis of the hematoma defined. The CB-CT data were then used to guide transcranial access to the hematoma-defining the location of the burr hole and the path to the leading edge of the hematoma. An 8F vascular sheath was then placed under live fluoroscopic guidance into the hematoma. A second CB-CT was performed to confirm localization of the sheath. The hematoma was then demarcated on the CB-CT and the Apollo wand was introduced through the 8F sheath and irrigation-aspiration was performed under (periodic) live fluoroscopic guidance. The operators manipulated the wand within the visible boundaries of the hematoma. After irrigation-aspiration, a control CB-CT was performed to document reduction in hematoma volume. Transvascular and transcranial techniques were both successful in creating intracranial hematomas. Hematomas could be defined with conspicuity sufficient for localization and volumetric measurement using CB-CT. Live fluoroscopic guidance was effective in navigating a sheath into the leading aspect of a parenchymal hematoma and guiding irrigation-aspiration with the Apollo system. Irrigation-aspiration reduced the parenchymal hemorrhage volume from 14.8 to 1.7 cc in 189 s in the first case (parenchymal hemorrhage) and from 26.4 to 4.1 cc in 300 s in the second case (parenchymal and intraventricular hemorrhage). The cadaver model described is a useful means of studying interventional techniques for intracranial hemorrhage. It seems feasible to use CB-CT to guide the evacuation of intraparenchymal and intraventricular hemorrhage using the Apollo system through a minimally invasive transcranial access. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
CyberKnife frameless single-fraction stereotactic radiosurgery for tumors of the sacrum.
Gerszten, Peter C; Ozhasoglu, Cihat; Burton, Steven A; Welch, William C; Vogel, William J; Atkins, Barbara A; Kalnicki, Shalom
2003-08-15
The role of stereotactic radiosurgery for the treatment of intracranial lesions is well established. The experience with radiosurgery for the treatment of spinal and sacral lesions is more limited. Sacral lesions should be amenable to radiosurgical treatment similar to that used for their intracranial counterparts. The authors evaluated a single- fraction radiosurgical technique performed using the CyberKnife Real-Time Image-Guided Radiosurgery System for the treatment of the sacral lesion. The CyberKnife is a frameless radiosurgery system based on the coupling of an orthogonal pair of x-ray cameras to a dynamically manipulated robot-mounted linear accelerator possessing six degrees of freedom, which guides the therapy beam to the intended target without the need for frame-based fixation. All sacral lesions were located and tracked for radiation delivery relative to fiducial bone markers placed percutaneously. Eighteen patients were treated with single-fraction radiosurgery. Tumor histology included one benign and 17 malignant tumors. Dose plans were calculated based on computerized tomography scans acquired using 1.25-mm slices. Planning treatment volume was defined as the radiographically documented tumor volume with no margin. Tumor dose was maintained at 12 to 20 Gy to the 80% isodose line (mean 15 Gy). Tumor volume ranged from 23.6 to 187.4 ml (mean 90 ml). The volume of the cauda equina receiving greater than 8 Gy ranged from 0 to 1 ml (mean 0.1 ml). All patients underwent the procedure in an outpatient setting. No acute radiation toxicity or new neurological deficits occurred during the mean follow-up period of 6 months. Pain improved in all 13 patients who were symptomatic prior to treatment. No tumor progression has been documented on follow-up imaging. Stereotactic radiosurgery was found to be feasible, safe, and effective for the treatment of both benign and malignant sacral lesions. The major potential benefits of radiosurgical ablation of sacral lesions are relatively short treatment time in an outpatient setting and minimal or no side effects. This new technique offers a new and important therapeutic modality for the primary treatment of a variety of sacral tumors or for lesions not amenable to open surgical techniques.
[Stereotactic biopsy in the accurate diagnosis of lesions in the brain stem and deep brain].
Qin, F; Huang, Z C; Cai, M Q; Xu, X F; Lu, T T; Dong, Q; Wu, A M; Lu, Z Z; Zhao, C; Guo, Y
2018-06-12
Objective: To investigate the value of stereotactic biopsy in the accurate diagnosis of lesions in the brain stem and deep brain. Methods: A total of 29 consecutive patients who underwent stereotactic biopsy of brainstem and deep brain lesions between May 2012 and January 2018 were retrospectively reviewed. The Cosman-Roberts-Wells (CRW) stereotactic frame was installed under local anesthesia. Thin-layer CT and MRI scanning were performed. Target coordinates were calculated by inputting CT-MRI data into the radionics surgical planning system. The individualized puncture path was designed according to the location of the lesions and the characteristics of the image. Target distributions were as follows: 12 cases of midbrain or pons, 2 cases of internal capsule, 3 cases of thalamus, 12 cases of basal ganglia. The biopsy samples were used for further pathological and/or genetic diagnosis. Results: Twenty-eight of the 29 cases (96.6%) were diagnosed accurately by histopathology and genomic examination following stereotactic biopsy. Pathological results were as follows: 8 cases of lymphoma, 7 cases of glioma, 4 cases of demyelination, 2 cases of germ cell tumor, 2 cases of metastatic tumor, 1 cases of cerebral sparganosis, 1 case of tuberculous granuloma, 1 case of hereditary prion disease, 1 case of glial hyperplasia, 1 case of leukemia. The accurate diagnosis of one case required a combination of histopathology and genomic examination. Undefined diagnosis was still made in 1 cases (3.45%) after biopsy. After biopsy, there were 2 cases (6.9%) with symptomatic slight hemorrhage, 1 case (3.45%) with symptomatic severe hemorrhage, and 1 cass (3.45%) with permanent neurological dysfunction. No one died because of surgery or surgical complications. Conclusions: Stereotactic biopsy is fast, safe and minimally invasive. It is an ideal strategy for accurate diagnosis of lesions in brain stem and deep brain.
Snider, James W; Mutaf, Yildirim; Nichols, Elizabeth; Hall, Andrea; Vadnais, Patrick; Regine, William F; Feigenberg, Steven J
2017-01-01
Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved with the device and intensity-modulated radiation therapy accelerated partial breast irradiation. Nine patients underwent computed tomography simulation in the prone position using device-specific immobilization on an institutional review board-approved protocol. Accelerated partial breast irradiation target volumes (planning target volume_10mm) were created per the National Surgical Adjuvant Breast and Bowel Project B-39 protocol. Additional breast stereotactic radiotherapy volumes using smaller margins (planning target volume_3mm) were created based on improved immobilization. Intensity-modulated radiation therapy and breast stereotactic radiotherapy accelerated partial breast irradiation plans were separately generated for appropriate volumes. Plans were evaluated based on established dosimetric surrogates of poor cosmetic outcomes. Wilcoxon rank sum tests were utilized to contrast volumes of critical structures receiving a percentage of total dose ( Vx). The breast stereotactic radiotherapy device consistently reduced dose to all normal structures with equivalent target coverage. The ipsilateral breast V20-100 was significantly reduced ( P < .05) using planning target volume_10mm, with substantial further reductions when targeting planning target volume_3mm. Doses to the chest wall, ipsilateral lung, and breast skin were also significantly lessened. The breast stereotactic radiotherapy device's uniform dosimetric improvements over intensity-modulated accelerated partial breast irradiation in this series indicate a potential to improve outcomes. Clinical trials investigating this benefit have begun accrual.
Cohen-Inbar, Or; Ding, Dale; Chen, Ching-Jen; Sheehan, Jason P
2016-02-01
The management of brainstem arteriovenous malformations (AVM) are one of the greatest challenges encountered by neurosurgeons. Brainstem AVM have a higher risk of hemorrhage compared to AVM in other locations, and rupture of these lesions commonly results in devastating neurological morbidity and mortality. The potential morbidity associated with currently available treatment modalities further compounds the complexity of decision making for affected patients. Stereotactic radiosurgery (SRS) has an important role in the management of brainstem AVM. SRS offers acceptable obliteration rates with lower risks of hemorrhage occurring during the latency period. Complex nidal architecture requires a multi-disciplinary treatment approach. Nidi partly involving subpial/epipial regions of the dorsal midbrain or cerebellopontine angle should be considered for a combination of endovascular embolization, micro-surgical resection and SRS. Considering the fact that incompletely obliterated lesions (even when reduced in size) could still cause lethal hemorrhages, additional treatment, including repeat SRS and surgical resection should be considered when complete obliteration is not achieved by first SRS. Patients with brainstem AVM require continued clinical and radiological observation and follow-up after SRS, well after angiographic obliteration has been confirmed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Badakhshi, Harun; Graf, Reinhold; Prasad, Vikas; Budach, Volker
2014-06-25
18 F-fluoro-ethyl-tyrosine PET is gaining more indications in the field of oncology. We investigated the potentials of usage of FET-PET/CT in addition to MRI for definition of gross tumor volume (GTV) in stereotactic radiotherapy of lesions of skull base. We included in a prospective setting 21 cases. An MRI was performed, completed by FET PET/CT. Different GTV's were defined based on respective imaging tools: 1. GTVMRI, 2. GTV MRI /CT, 3. GTV composit (1 + 2), and GTVPET = GTV Boost. Lesions could be visualised by MRI and FET-PET/CT in all patients. FET tracer enhancement was found in all cases. Skull base infiltration by these lesions was observed by MRI, CT (PET/CT) and FET-PET (PET/CT) in all patients. Totally, brain tissue infiltration was seen in 10 patients. While, in 7 (out 10) cases, MRI and CT (from PET/CT) were indicating brain infiltration, FET-PET could add additional information regarding infiltrative behaviour: in 3 (out 10) patients, infiltration of the brain was displayed merely in FET-PET. An enlargement of GTVMRI/CT due to the FET-PET driven information, which revealed GTVcomposite , was necessary in 7 cases,. This enlargement was significant by definition (> 10% of GTVMRI/CT). The mean PET-effect on GTV counted for 1 ± 4 cm3. The restricted boost fields were based mainly on the GTVPET volume. In mean, about 8.5 cm3 of GTVMRI/CT, which showed no FET uptake, were excluded from target volume. GTV boost driven by only-PET-activity, was in mean by 33% smaller than the initial large treatment field, GTV composite, for those cases received boost treatment. FET-PET lead to significant (>10%) changes in the initial treatment fields in 11/21 patients and showed additional tumour volume relevant for radiation planning in 6/21 cases, and led to a subsequent decrease of more than 10% of the initial volumes for the boost fields. The implementation of FET PET into the planning procedures showed a benefit in terms of accurate definition of skull base lesions as targets for Image-guided stereotactic Radiotherapy. This has to be investigated prospectively in larger cohorts.
Cost-effectiveness of focused ultrasound, radiosurgery, and DBS for essential tremor.
Ravikumar, Vinod K; Parker, Jonathon J; Hornbeck, Traci S; Santini, Veronica E; Pauly, Kim Butts; Wintermark, Max; Ghanouni, Pejman; Stein, Sherman C; Halpern, Casey H
2017-08-01
Essential tremor remains a very common yet medically refractory condition. A recent phase 3 study demonstrated that magnetic resonance-guided focused ultrasound thalamotomy significantly improved upper limb tremor. The objectives of this study were to assess this novel therapy's cost-effectiveness compared with existing procedural options. Literature searches of magnetic resonance-guided focused ultrasound thalamotomy, DBS, and stereotactic radiosurgery for essential tremor were performed. Pre- and postoperative tremor-related disability scores were collected from 32 studies involving 83 magnetic resonance-guided focused ultrasound thalamotomies, 615 DBSs, and 260 stereotactic radiosurgery cases. Utility, defined as quality of life and derived from percent change in functional disability, was calculated; Medicare reimbursement was employed as a proxy for societal cost. Medicare reimbursement rates are not established for magnetic resonance-guided focused ultrasound thalamotomy for essential tremor; therefore, reimbursements were estimated to be approximately equivalent to stereotactic radiosurgery to assess a cost threshold. A decision analysis model was constructed to examine the most cost-effective option for essential tremor, implementing meta-analytic techniques. Magnetic resonance-guided focused ultrasound thalamotomy resulted in significantly higher utility scores compared with DBS (P < 0.001) or stereotactic radiosurgery (P < 0.001). Projected costs of magnetic resonance-guided focused ultrasound thalamotomy were significantly less than DBS (P < 0.001), but not significantly different from radiosurgery. Magnetic resonance-guided focused ultrasound thalamotomy is cost-effective for tremor compared with DBS and stereotactic radiosurgery and more effective than both. Even if longer follow-up finds changes in effectiveness or costs, focused ultrasound thalamotomy will likely remain competitive with both alternatives. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.
Al-Omair, Ameen; Soliman, Hany; Xu, Wei; Karotki, Aliaksandr; Mainprize, Todd; Phan, Nicolas; Das, Sunit; Keith, Julia; Yeung, Robert; Perry, James; Tsao, May; Sahgal, Arjun
2013-12-01
Our purpose was to report efficacy of hypofractionated cavity stereotactic radiotherapy (HCSRT) in patients with and without prior whole brain radiotherapy (WBRT). 32 surgical cavities in 30 patients (20 patients/21 cavities had no prior WBRT and 10 patients/11 cavities had prior WBRT) were treated with image-guided linac stereotactic radiotherapy. 7 of the 10 prior WBRT patients had "resistant" local disease given prior surgery, post-operative WBRT and a re-operation, followed by salvage HCSRT. The clinical target volume was the post-surgical cavity, and a 2-mm margin applied as planning target volume. The median total dose was 30 Gy (range: 25-37.5 Gy) in 5 fractions. In the no prior and prior WBRT cohorts, the median follow-up was 9.7 months (range: 3.0-23.6) and 15.3 months (range: 2.9-39.7), the median survival was 23.6 months and 39.7 months, and the 1-year cavity local recurrence progression- free survival (LRFS) was 79 and 100%, respectively. At 18 months the LRFS dropped to 29% in the prior WBRT cohort. Grade 3 radiation necrosis occurred in 3 prior WBRT patients. We report favorable outcomes with HCSRT, and well selected patients with prior WBRT and "resistant" disease may have an extended survival favoring aggressive salvage HCSRT at a moderate risk of radiation necrosis.
Kuhlman, Gregory M; Taylor, Amanda R; Thieman-Mankin, Kelley M; Griffin, Jay; Cook, Audrey K; Levine, Jonathan M
2016-04-15
5 dogs (median age, 9 years; median body weight, 31 kg [68.2 lb]) with undefined nasal masses were examined after undergoing CT of the head and nasal biopsy via a rostral rhinoscopic or unaided (blind) approach because histologic results for collected biopsy specimens (inflammatory, necrotic, or hemorrhagic disease) suggested the specimens were nonrepresentative of the underlying disease process identified via CT (aggressive or malignant disease). Clinical signs at the time dogs were evaluated included open-mouth breathing, sneezing, or unilateral epistaxis. Histologic findings pertaining to the original biopsy specimens were suggestive of benign processes such as inflammation. In an attempt to obtain better representative specimens, a frameless CT-guided stereotactic biopsy system (CTSBS) was used to collect additional biopsy specimens from masses within the nasal and sinus passages of the dogs. The second set of biopsy specimens was histologically evaluated. Histologic evaluation of biopsy specimens collected via the CTSBS revealed results suggestive of malignant neoplasia (specifically, chondrosarcoma, hemangiopericytoma, or undifferentiated sarcoma) for 3 dogs, mild mixed-cell inflammation for 1 dog, and hamartoma for 1 dog. No complications were reported. These findings resulted in a change in treatment recommendations for 3 dogs and confirmed that no additional treatment was required for 1 dog (with hamartoma). For the remaining dog, in which CT findings and clinical history were strongly suggestive of neoplasia, the final diagnosis was rhinitis. Biopsy specimens were safely collected from masses within the nasal and sinus passages of dogs by use of a frameless CTSBS, allowing a definitive diagnosis that was unachievable with other biopsy approaches.
Intra-opeartive OCT imaging and sensing devices for clinical translation (Conference Presentation)
NASA Astrophysics Data System (ADS)
Chen, Yu
2017-02-01
Stereotactic procedures that require insertion of needle-based instruments into the brain serve important roles in a variety of neurosurgical interventions, such as biopsy, catheterization, and electrode placement. A fundamental limitation of these stereotactic procedures is that they are blind procedures in that the operator does not have real-time feedback as to what lies immediately ahead of the advancing needle. Therefore, there is a great clinical need to navigate the instrument safely and accurately to the targets. Towards that end, we developed a forwarding-imaging needle-type optical coherence tomography (OCT) probe for avoiding the hemorrhage and guiding neurosurgical interventions. The needle probe has a thin diameter of 0.7 mm. The feasibility of vessel detection and neurosurgical guidance were demonstrated on sheep brain in vivo and human brain ex vivo. In addition, we further reduced the probe size to 0.3 mm using an optical Doppler sensing (ODS) fiber probe that can integrate with microelectrode recording (MER) to detect the blood vessels lying ahead to improve the safety of this procedure. Furthermore, to overcome the field-of-view limitation of OCT probe, we developed an MRI-compatible OCT imaging probe for neurosurgery. MRI/OCT multi-scale imaging integrates micro-resolution optical imaging with wide-field MRI imaging, and has potential to further improve the targeting accuracy.
Ramey, Stephen James; Padgett, Kyle R; Lamichhane, Narottam; Neboori, Hanmath J; Kwon, Deukwoo; Mellon, Eric A; Brown, Karen; Duffy, Melissa; Victoria, James; Dogan, Nesrin; Portelance, Lorraine
2018-03-01
This study aims to perform a dosimetric comparison of 2 magnetic resonance (MR)-guided radiation therapy systems capable of performing online adaptive radiation therapy versus a conventional radiation therapy system for pancreas stereotactic body radiation therapy. Ten cases of patients with pancreatic adenocarcinoma previously treated in our institution were used for this analysis. MR-guided tri-cobalt 60 therapy (MR-cobalt) and MR-LINAC plans were generated and compared with conventional LINAC (volumetric modulated arc therapy) plans. The prescription dose was 40 Gy in 5 fractions covering 95% of the planning tumor volume for the 30 plans. The same organs at risk (OARs) dose constraints were used in all plans. Dose-volume-based indices were used to compare PTV coverage and OAR sparing. The conformity index of 40 Gy in 5 fractions covering 95% of the planning tumor volume demonstrated higher conformity in both LINAC-based plans compared with MR-cobalt plans. Although there was no difference in mean conformity index between LINAC and MR-LINAC plans (1.08 in both), there was a large difference between LINAC and MR-cobalt plans (1.08 vs 1.52). Overall, 79%, 72%, and 78% of critical structure dosimetric constraints were met with LINAC, MR-cobalt, and MR-LINAC plans, respectively. The MR-cobalt plans delivered more doses to all OARs compared with the LINAC plans. In contrast, the doses to the OARs of the MR-LINAC plans were similar to LINAC plans except in 2 cases: liver mean dose (MR-LINAC, 2 .8 Gy vs LINAC, 2.1 Gy) and volume of duodenum receiving at least 15 Gy (MR-LINAC, 13.2 mL vs LINAC, 15.4 mL). Both differences are likely not clinically significant. This study demonstrates that dosimetrically similar plans were achieved with conventional LINAC and MR-LINAC, whereas doses to OARs were statistically higher for MR-cobalt compared with conventional LINAC plans because of low-dose spillage. Given the improved tumor-tracking capabilities of MR-LINAC, further studies should evaluate potential benefits of adaptive radiation therapy-capable MR-guided LINAC treatment. Copyright © 2018. Published by Elsevier Inc.
Laser interstitial thermal therapy for medically intractable mesial temporal lobe epilepsy.
Kang, Joon Y; Wu, Chengyuan; Tracy, Joseph; Lorenzo, Matthew; Evans, James; Nei, Maromi; Skidmore, Christopher; Mintzer, Scott; Sharan, Ashwini D; Sperling, Michael R
2016-02-01
To describe mesial temporal lobe ablated volumes, verbal memory, and surgical outcomes in patients with medically intractable mesial temporal lobe epilepsy (mTLE) treated with magnetic resonance imaging (MRI)-guided stereotactic laser interstitial thermal therapy (LiTT). We prospectively tracked seizure outcome in 20 patients at Thomas Jefferson University Hospital with drug-resistant mTLE who underwent MRI-guided LiTT from December 2011 to December 2014. Surgical outcome was assessed at 6 months, 1 year, 2 years, and at the most recent visit. Volume-based analysis of ablated mesial temporal structures was conducted in 17 patients with mesial temporal sclerosis (MTS) and results were compared between the seizure-free and not seizure-free groups. Following LiTT, proportions of patients who were free of seizures impairing consciousness (including those with auras only) are as follows: 8 of 15 patients (53%, 95% confidence interval [CI] 30.1-75.2%) after 6 months, 4 of 11 patients (36.4%, 95% CI 14.9-64.8%) after 1 year, 3 of 5 patients (60%, 95% CI 22.9-88.4%) at 2-year follow-up. Median follow-up was 13.4 months after LiTT (range 1.3 months to 3.2 years). Seizure outcome after LiTT suggests an all or none response. Four patients had anterior temporal lobectomy (ATL) after LiTT; three are seizure-free. There were no differences in total ablated volume of the amygdalohippocampus complex or individual volumes of hippocampus, amygdala, entorhinal cortex, parahippocampal gyrus, and fusiform gyrus between seizure-free and non-seizure-free patients. Contextual verbal memory performance was preserved after LiTT, although decline in noncontextual memory task scores were noted. We conclude that MRI-guided stereotactic LiTT is a safe alternative to ATL in patients with medically intractable mTLE. Individualized assessment is warranted to determine whether the reduced odds of seizure freedom are worth the reduction in risk, discomfort, and recovery time. Larger prospective studies are needed to confirm our preliminary findings, and to define optimal ablation volume and ideal structures for ablation. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.
NASA Astrophysics Data System (ADS)
Strulik, Konrad L.; Cho, Min H.; Collins, Brian T.; Khan, Noureen; Banovac, Filip; Slack, Rebecca; Cleary, Kevin
2008-03-01
To track respiratory motion during CyberKnife stereotactic radiosurgery in the lung, several (three to five) cylindrical gold fiducials are implanted near the planned target volume (PTV). Since these fiducials remain in the human body after treatment, we hypothesize that tracking fiducial movement over time may correlate with the tumor response to treatment and pulmonary fibrosis, thereby serving as an indicator of treatment success. In this paper, we investigate fiducial migration in 24 patients through examination of computed tomography (CT) volume images at four time points: pre-treatment, three, six, and twelve month post-treatment. We developed a MATLAB based GUI environment to display the images, identify the fiducials, and compute our performance measure. After we semi-automatically segmented and detected fiducial locations in CT images of the same patient over time, we identified them according to their configuration and introduced a relative performance measure (ACD: average center distance) to detect their migration. We found that the migration tended to result in a movement towards the fiducial center of the radiated tissue area (indicating tumor regression) and may potentially be linked to the patient prognosis.
Ma, Sung Jun; Mix, Michael; Rivers, Charlotte; Hennon, Mark; Gomez, Jorge
2017-01-01
The case of a 56-year-old male who developed bronchopulmonary hemorrhage after a course of stereotactic body radiation therapy (SBRT) for centrally located squamous cell lung carcinoma is presented. The patient was previously treated with concurrent chemoradiation for stage IVA squamous cell carcinoma of the base of tongue. He showed no evidence of disease for 4 years until he developed a solitary metastasis of squamous cell carcinoma in the right hilum. He underwent a single fraction of 26 Gy with heterogeneity correction. He showed no evidence of disease for 13 months until he developed a sudden grade 4 bronchopulmonary hemorrhage. He underwent an urgent right pneumonectomy and later died of a post-operative complication. Pathologic analysis of the specimen revealed no evidence of tumor. Single-fraction SBRT of 26 Gy was sufficient to achieve complete response of his large central lung tumor. However, when treating patients with central lung tumors, some risk of mortality may be unavoidable with either SBRT or pneumonectomy. PMID:29296456
Zhang, Yan; Yang, Yang; Zhang, Guang-Zhu; Gao, Mou; Ge, Guang-Zhi; Wang, Qin-Qin; Ji, Xin-Chao; Sun, Yi-Lin; Zhang, Hong-Tian; Xu, Ru-Xiang
2016-10-01
Edaravone is widely used for treating ischemic stroke, but it is not still confirmed in intracerebral hemorrhage (ICH) as an ideal medication targeting the brain parenchyma. We aimed to investigate the neuroprotective effects of stereotactic administration of edaravone (SI) into the brain parenchyma. Intracerebral hemorrhage rat models were established by infusion of collagenase into the caudate nucleus. Neural functional recovery was assessed using modified neurological severity scores (mNSS). A comparative study of therapeutic effects between SI and intraperitoneal injection of edaravone (IP) involved in cerebral edema, blood-brain barrier (BBB) permeability, hematoma absorption, inflammatory response and neuronal apoptosis. Compared with IP, the mNSS was significantly (P < 0.05) improved by SI; cerebral edema and BBB permeability were dramatically ameliorated (P < 0.05); IL-4 and IL-10 levels increased, but IL-1β and TNF-α levels significantly decreased; neuron apoptosis decreased markedly (P < 0.05); and caspase-3 and Bax expression significantly dropped, but Bcl-2 increased in SI group (P < 0.05). SI markedly improved neurological deficits in ICH rat models via antiinflammatory and antiapoptosis mechanisms and promoted M2-type microglia differentiation. SI was effective in rats with collagenase-induced ICH. © 2016 The Authors. CNS Neuroscience & Therapeutics Published by John Wiley & Sons Ltd.
Cerebral cavernous malformations: natural history and clinical management.
Gross, Bradley A; Du, Rose
2015-01-01
Cavernous malformations (CMs) are angiographically-occult clusters of dilated sinusoidal channels that may present clinically with seizures, focal neurological deficits and/or hemorrhage. Across natural history studies, the annual hemorrhage rate ranged from 1.6-3.1% per patient-year, decreasing to 0.08-0.2% per patient-year for incidental CMs and to 0.3-0.6% for the collective group of unruptured CMs. Prior hemorrhage is a significant risk factor for subsequent CM hemorrhage. Hemorrhage clustering, particularly within the first 2 years, is an established phenomenon that may confound results of natural history studies evaluating the rate of rehemorrhage. Indeed, rehemorrhage rates for hemorrhagic CMs range from 4.5-22.9% in the literature. Surgical resection is the gold standard treatment for surgically-accessible, symptomatic CMs. Incidental CMs or minimally symptomatic, surgically inaccessible eloquent lesions may be considered for observation. Stereotactic radiosurgery is a controversial treatment approach of consideration only for cases of highly aggressive, surgically inaccessible CMs.
Al-Omair, Ameen; Soliman, Hany; Xu, Wei; Karotki, Aliaksandr; Mainprize, Todd; Phan, Nicolas; Das, Sunit; Keith, Julia; Yeung, Robert; Perry, James; Tsao, May; Sahgal, Arjun
2013-01-01
Our purpose was to report efficacy of hypofractionated cavity stereotactic radiotherapy (HCSRT) in patients with and without prior whole brain radiotherapy (WBRT). 32 surgical cavities in 30 patients (20 patients/21 cavities had no prior WBRT and 10 patients/11 cavities had prior WBRT) were treated with image-guided linac stereotactic radiotherapy. 7 of the 10 prior WBRT patients had “resistant” local disease given prior surgery, post-operative WBRT and a re-operation, followed by salvage HCSRT. The clinical target volume was the post-surgical cavity, and a 2-mm margin applied as planning target volume. The median total dose was 30 Gy (range: 25-37.5 Gy) in 5 fractions. In the no prior and prior WBRT cohorts, the median follow-up was 9.7 months (range: 3.0-23.6) and 15.3 months (range: 2.9-39.7), the median survival was 23.6 months and 39.7 months, and the 1-year cavity local recurrence progression-free survival (LRFS) was 79 and 100%, respectively. At 18 months the LRFS dropped to 29% in the prior WBRT cohort. Grade 3 radiation necrosis occurred in 3 prior WBRT patients. We report favorable outcomes with HCSRT, and well selected patients with prior WBRT and “resistant” disease may have an extended survival favoring aggressive salvage HCSRT at a moderate risk of radiation necrosis. PMID:23617283
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsegmed, Uranchimeg; Kimura, Tomoki, E-mail: tkkimura@hiroshima-u.ac.jp; Nakashima, Takeo
The aim of the current planning study is to evaluate the ability of gadoxetate disodium-enhanced magnetic resonance imaging (EOB-MRI)–guided stereotactic body radiation therapy (SBRT) planning by using intensity-modulated radiation therapy (IMRT) techniques in sparing the functional liver tissues during SBRT for hepatocellular carcinoma. In this study, 20 patients with hepatocellular carcinoma were enrolled. Functional liver tissues were defined according to quantitative liver-spleen contrast ratios ≥ 1.5 on a hepatobiliary phase scan. Functional images were fused with the planning computed tomography (CT) images; the following 2 SBRT plans were designed using a “step-and-shoot” static IMRT technique for each patient: (1) an anatomicalmore » SBRT plan optimization based on the total liver; and (2) a functional SBRT plan based on the functional liver. The total prescribed dose was 48 gray (Gy) in 4 fractions. Dosimetric parameters, including dose to 95% of the planning target volume (PTV D{sub 95%}), percentages of total and functional liver volumes, which received doses from 5 to 30 Gy (V5 to V30 and fV5 to fV30), and mean doses to total and functional liver (MLD and fMLD, respectively) of the 2 plans were compared. Compared with anatomical plans, functional image-guided SBRT plans reduced MLD (mean: plan A, 5.5 Gy; and plan F, 5.1 Gy; p < 0.0001) and fMLD (mean: plan A, 5.4 Gy; and plan F, 4.9 Gy; p < 0.0001), as well as V5 to V30 and fV5 to fV30. No differences were noted in PTV coverage and nonhepatic organs at risk (OARs) doses. In conclusion, EOB-MRI–guided SBRT planning using the IMRT technique may preserve functional liver tissues in patients with hepatocellular carcinoma (HCC).« less
Microwave coagulation therapy and drug injection to treat splenic injury.
Zhang, Guoming; Sun, Yuanyuan; Yu, Jie; Dong, Lei; Mu, Nannan; Liu, Xiaohong; Liu, Lanfen; Zhang, Yan; Wang, Xiaofei; Liang, Ping
2014-01-01
The present study compares the efficacy of 915- and 2450-MHz contrast-enhanced ultrasound (CEUS)-guided percutaneous microwave coagulation with that of CEUS-guided thrombin injection for the treatment of trauma-induced spleen hemorrhage. In a canine splenic artery hemorrhage model with two levels of arterial diameter (A, <1 mm and B, between 1 and 2 mm), hemostatic therapy was performed using 915- and 2450-MHz microwaves and drug injection. Therapy efficacy was measured by comparing bleeding rate, hemostatic time, bleeding index, bleeding volume, and pathology. The most efficient technique was CEUS-guided 915-MHz percutaneous microwave coagulation therapy in terms of action time and total blood loss. The success rate of the 915-MHz microwave group was higher than that of the 2450-MHz microwave and the drug injection groups (except A level, P < 0.05). Hemostatic time, bleeding index, and bleeding volume were significantly less in the 915-MHz microwave group than those in the 2450-MHz microwave and drug injection groups (P < 0.05). Obvious degeneration and necrosis of parenchyma and large intravascular thrombosis were observed in the cavity of larger vessels in the 915-MHz microwave group, but pathologic changes of light injury could be seen in the other groups. The present study provides evidence that microwave coagulation therapy is more efficient than thrombin injection for the treatment of splenic hemorrhage. Furthermore, treatment with 915-MHz microwaves stops bleeding more rapidly and generates a wider cauterization zone than does treatment with 2450-MHz microwaves. Copyright © 2014 Elsevier Inc. All rights reserved.
Gamma Knife radiosurgery for hemangioma of the cavernous sinus.
Lee, Cheng-Chia; Sheehan, Jason P; Kano, Hideyuki; Akpinar, Berkcan; Martinez-Alvarez, Roberto; Martinez-Moreno, Nuria; Guo, Wan-Yuo; Lunsford, L Dade; Liu, Kang-Du
2017-05-01
OBJECTIVE Cavernous sinus hemangiomas (CSHs) are rare vascular tumors. A direct microsurgical approach usually results in massive hemorrhage and incomplete tumor resection. Although stereotactic radiosurgery (SRS) has emerged as a therapeutic alternative to microsurgery, outcome studies are few. Authors of the present study evaluated the role of SRS for CSH. METHODS An international multicenter study was conducted to review outcome data in 31 patients with CSH. Eleven patients had initial microsurgery before SRS, and the other 20 patients (64.5%) underwent Gamma Knife SRS as the primary management for their CSH. Median age at the time of radiosurgery was 47 years, and 77.4% of patients had cranial nerve dysfunction before SRS. Patients received a median tumor margin dose of 12.6 Gy (range 12-19 Gy) at a median isodose of 55%. RESULTS Tumor regression was confirmed by imaging in all 31 patients, and all patients had greater than 50% reduction in tumor volume at 6 months post-SRS. No patient had delayed tumor growth, new cranial neuropathy, visual function deterioration, adverse radiation effects, or hypopituitarism after SRS. Twenty-four patients had presented with cranial nerve disorders before SRS, and 6 (25%) of them had gradual improvement. Four (66.7%) of the 6 patients with orbital symptoms had symptomatic relief at the last follow-up. CONCLUSIONS Stereotactic radiosurgery was effective in reducing the volume of CSH and attaining long-term tumor control in all patients at a median of 40 months. The authors' experience suggests that SRS is a reasonable primary and adjuvant treatment modality for patients in whom a CSH is diagnosed.
Tagaste, Barbara; Riboldi, Marco; Spadea, Maria F; Bellante, Simone; Baroni, Guido; Cambria, Raffaella; Garibaldi, Cristina; Ciocca, Mario; Catalano, Gianpiero; Alterio, Daniela; Orecchia, Roberto
2012-04-01
To compare infrared (IR) optical vs. stereoscopic X-ray technologies for patient setup in image-guided stereotactic radiotherapy. Retrospective data analysis of 233 fractions in 127 patients treated with hypofractionated stereotactic radiotherapy was performed. Patient setup at the linear accelerator was carried out by means of combined IR optical localization and stereoscopic X-ray image fusion in 6 degrees of freedom (6D). Data were analyzed to evaluate the geometric and dosimetric discrepancy between the two patient setup strategies. Differences between IR optical localization and 6D X-ray image fusion parameters were on average within the expected localization accuracy, as limited by CT image resolution (3 mm). A disagreement between the two systems below 1 mm in all directions was measured in patients treated for cranial tumors. In extracranial sites, larger discrepancies and higher variability were observed as a function of the initial patient alignment. The compensation of IR-detected rotational errors resulted in a significantly improved agreement with 6D X-ray image fusion. On the basis of the bony anatomy registrations, the measured differences were found not to be sensitive to patient breathing. The related dosimetric analysis showed that IR-based patient setup caused limited variations in three cases, with 7% maximum dose reduction in the clinical target volume and no dose increase in organs at risk. In conclusion, patient setup driven by IR external surrogates localization in 6D featured comparable accuracy with respect to procedures based on stereoscopic X-ray imaging. Copyright © 2012 Elsevier Inc. All rights reserved.
Starke, Robert M; Ding, Dale; Kano, Hideyuki; Mathieu, David; Huang, Paul P; Feliciano, Caleb; Rodriguez-Mercado, Rafael; Almodovar, Luis; Grills, Inga S; Silva, Danilo; Abbassy, Mahmoud; Missios, Symeon; Kondziolka, Douglas; Barnett, Gene H; Dade Lunsford, L; Sheehan, Jason P
2017-02-01
OBJECTIVE Pediatric patients (age < 18 years) harboring brain arteriovenous malformations (AVMs) are burdened with a considerably higher cumulative lifetime risk of hemorrhage than adults. Additionally, the pediatric population was excluded from recent prospective comparisons of intervention versus conservative management for unruptured AVMs. The aims of this multicenter, retrospective cohort study are to analyze the outcomes after stereotactic radiosurgery for unruptured and ruptured pediatric AVMs. METHODS We analyzed and pooled AVM radiosurgery data from 7 participating in the International Gamma Knife Research Foundation. Patients younger than 18 years of age who had at least 12 months of follow-up were included in the study cohort. Favorable outcome was defined as AVM obliteration, no post-radiosurgical hemorrhage, and no permanently symptomatic radiation-induced changes (RIC). The post-radiosurgery outcomes of unruptured versus ruptured pediatric AVMs were compared, and statistical analyses were performed to identify predictive factors. RESULTS The overall pediatric AVM cohort comprised 357 patients with a mean age of 12.6 years (range 2.8-17.9 years). AVMs were previously treated with embolization, resection, and fractionated external beam radiation therapy in 22%, 6%, and 13% of patients, respectively. The mean nidus volume was 3.5 cm 3 , 77% of AVMs were located in eloquent brain areas, and the Spetzler-Martin grade was III or higher in 59%. The mean radiosurgical margin dose was 21 Gy (range 5-35 Gy), and the mean follow-up was 92 months (range 12-266 months). AVM obliteration was achieved in 63%. During a cumulative latency period of 2748 years, the annual post-radiosurgery hemorrhage rate was 1.4%. Symptomatic and permanent radiation-induced changes occurred in 8% and 3%, respectively. Favorable outcome was achieved in 59%. In the multivariate logistic regression analysis, the absence of prior AVM embolization (p = 0.001) and higher margin dose (p < 0.001) were found to be independent predictors of a favorable outcome. The rates of favorable outcome for patients treated with a margin dose ≥ 22 Gy vs < 22 Gy were 78% (110/141 patients) and 47% (101/216 patients), respectively. A margin dose ≥ 22 Gy yielded a significantly higher probability of a favorable outcome (p < 0.001). The unruptured and ruptured pediatric AVM cohorts included 112 and 245 patients, respectively. Ruptured AVMs had significantly higher rates of obliteration (68% vs 53%, p = 0.005) and favorable outcome (63% vs 51%, p = 0.033), with a trend toward a higher incidence of post-radiosurgery hemorrhage (10% vs 4%, p = 0.07). The annual post-radiosurgery hemorrhage rates were 0.8% for unruptured and 1.6% for ruptured AVMs. CONCLUSIONS Radiosurgery is a reasonable treatment option for pediatric AVMs. Obliteration and favorable outcomes are achieved in the majority of patients. The annual rate of latency period hemorrhage after radiosurgery for both ruptured and unruptured pediatric AVM patients conveys a significant risk until the nidus is obliterated.
Han, Chunhui; Sampath, Sagus; Schultheisss, Timothy E; Wong, Jeffrey Y C
2017-01-01
We aimed to compare gross tumor volumes (GTV) in 3-dimensional computed tomography (3DCT) simulation and daily cone beam CT (CBCT) with the internal target volume (ITV) in 4-dimensional CT (4DCT) simulation in stereotactic body radiotherapy (SBRT) treatment of patients with early-stage non-small cell lung cancer (NSCLC) under abdominal compression. We retrospectively selected 10 patients with NSCLC who received image-guided SBRT treatments under abdominal compression with daily CBCT imaging. GTVs were contoured as visible gross tumor on the planning 3DCT and daily CBCT, and ITVs were contoured using maximum intensity projection (MIP) images of the planning 4DCT. Daily CBCTs were registered with 3DCT and MIP images by matching of bony landmarks in the thoracic region to evaluate interfractional GTV position variations. Relative to MIP-based ITVs, the average 3DCT-based GTV volume was 66.3 ± 17.1% (range: 37.5% to 92.0%) (p < 0.01 in paired t-test), and the average CBCT-based GTV volume was 90.0 ± 6.7% (daily range: 75.7% to 107.1%) (p = 0.02). Based on bony anatomy matching, the center-of-mass coordinates for CBCT-based GTVs had maximum absolute shift of 2.4 mm (left-right), 7.0 mm (anterior-posterior [AP]), and 5.2 mm (superior-inferior [SI]) relative to the MIP-based ITV. CBCT-based GTVs had average overlapping ratio of 81.3 ± 11.2% (range: 45.1% to 98.9%) with the MIP-based ITV, and 57.7 ± 13.7% (range: 35.1% to 83.2%) with the 3DCT-based GTV. Even with abdominal compression, both 3DCT simulations and daily CBCT scans significantly underestimated the full range of tumor motion. In daily image-guided patient setup corrections, automatic bony anatomy-based image registration could lead to target misalignment. Soft tissue-based image registration should be performed for accurate treatment delivery. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Chunhui, E-mail: chan@coh.org; Sampath, Sagus; Schultheisss, Timothy E.
We aimed to compare gross tumor volumes (GTV) in 3-dimensional computed tomography (3DCT) simulation and daily cone beam CT (CBCT) with the internal target volume (ITV) in 4-dimensional CT (4DCT) simulation in stereotactic body radiotherapy (SBRT) treatment of patients with early-stage non–small cell lung cancer (NSCLC) under abdominal compression. We retrospectively selected 10 patients with NSCLC who received image-guided SBRT treatments under abdominal compression with daily CBCT imaging. GTVs were contoured as visible gross tumor on the planning 3DCT and daily CBCT, and ITVs were contoured using maximum intensity projection (MIP) images of the planning 4DCT. Daily CBCTs were registeredmore » with 3DCT and MIP images by matching of bony landmarks in the thoracic region to evaluate interfractional GTV position variations. Relative to MIP-based ITVs, the average 3DCT-based GTV volume was 66.3 ± 17.1% (range: 37.5% to 92.0%) (p < 0.01 in paired t-test), and the average CBCT-based GTV volume was 90.0 ± 6.7% (daily range: 75.7% to 107.1%) (p = 0.02). Based on bony anatomy matching, the center-of-mass coordinates for CBCT-based GTVs had maximum absolute shift of 2.4 mm (left-right), 7.0 mm (anterior-posterior [AP]), and 5.2 mm (superior-inferior [SI]) relative to the MIP-based ITV. CBCT-based GTVs had average overlapping ratio of 81.3 ± 11.2% (range: 45.1% to 98.9%) with the MIP-based ITV, and 57.7 ± 13.7% (range: 35.1% to 83.2%) with the 3DCT-based GTV. Even with abdominal compression, both 3DCT simulations and daily CBCT scans significantly underestimated the full range of tumor motion. In daily image-guided patient setup corrections, automatic bony anatomy-based image registration could lead to target misalignment. Soft tissue-based image registration should be performed for accurate treatment delivery.« less
Hong, Zhen-Yu; Lee, Hae-June; Choi, Won Hoon; Lee, Yoon-Jin; Eun, Sung Ho; Lee, Jung Il; Park, Kwangwoo; Lee, Ji Min; Cho, Jaeho
2014-07-01
In a previous study, we established an image-guided small-animal micro-irradiation system mimicking clinical stereotactic body radiotherapy (SBRT). The goal of this study was to develop a rodent model of acute phase lung injury after ablative irradiation. A radiation dose of 90 Gy was focally delivered to the left lung of C57BL/6 mice using a small animal stereotactic irradiator. At days 1, 3, 5, 7, 9, 11 and 14 after irradiation, the lungs were perfused with formalin for fixation and paraffin sections were stained with hematoxylin and eosin (H&E) and Masson's trichrome. At days 7 and 14 after irradiation, micro-computed tomography (CT) images of the lung were taken and lung functional measurements were performed with a flexiVent™ system. Gross morphological injury was evident 9 days after irradiation of normal lung tissues and dynamic sequential events occurring during the acute phase were validated by histopathological analysis. CT images of the mouse lungs indicated partial obstruction located in the peripheral area of the left lung. Significant alteration in inspiratory capacity and tissue damping were detected on day 14 after irradiation. An animal model of radiation-induced lung injury (RILI) in the acute phase reflecting clinical stereotactic body radiotherapy was established and validated with histopathological and functional analysis. This model enhances our understanding of the dynamic sequential events occurring in the acute phase of radiation-induced lung injury induced by ablative dose focal volume irradiation.
Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.
Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu
2015-11-01
Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.
A convolutional neural network for intracranial hemorrhage detection in non-contrast CT
NASA Astrophysics Data System (ADS)
Patel, Ajay; Manniesing, Rashindra
2018-02-01
The assessment of the presence of intracranial hemorrhage is a crucial step in the work-up of patients requiring emergency care. Fast and accurate detection of intracranial hemorrhage can aid treating physicians by not only expediting and guiding diagnosis, but also supporting choices for secondary imaging, treatment and intervention. However, the automatic detection of intracranial hemorrhage is complicated by the variation in appearance on non-contrast CT images as a result of differences in etiology and location. We propose a method using a convolutional neural network (CNN) for the automatic detection of intracranial hemorrhage. The method is trained on a dataset comprised of cerebral CT studies for which the presence of hemorrhage has been labeled for each axial slice. A separate test dataset of 20 images is used for quantitative evaluation and shows a sensitivity of 0.87, specificity of 0.97 and accuracy of 0.95. The average processing time for a single three-dimensional (3D) CT volume was 2.7 seconds. The proposed method is capable of fast and automated detection of intracranial hemorrhages in non-contrast CT without being limited to a specific subtype of pathology.
The detection of chronic cerebral hemorrhage in rabbits with magnetic induction
NASA Astrophysics Data System (ADS)
Sun, Jian; Jin, Gui; Qin, Mingxin; Wan, Zibing; Wang, Jinbao; ChaoWang; Guo, Wanyou; Xu, Lin; Ning, Xu; Xu, Jia; Pu, Xianjie; Chen, Mingsheng; Zhao, Hongmei
2012-12-01
Chronic cerebral hemorrhage (CCH) in the brain is an important clinical problem that is often monitored and studied with expensive devices such as MRI and PET, which are not readily available in low economical resource parts of the world. We have developed a less expensive tool for non-contact monitoring of CCH in the brain. The system measures the phase shift between the electromagnetic signals on the two coils. CCH was induced in the brain of rabbits by stereotactic method. Intracranial pressure (ICP) and Electrocardiograph (ECG) of subjects were monitored for 1.5h. Signals were continuously monitored up to t=1.5h at exciting frequency 10.7MHz. From 0.8 to 2.4 ml of autologous blood was injected (each injection quantity of 0.8 ml, the interval time for 30 minutes). The results show significant phase shifts increase as a function of injection volume. ICP and phase shift were directly proportional to the related, while HRV were stable around 200beats*min-1. Our system has high sensitivity that even 0.8 ml can also be detected. In this study, the curves of inductive phase shift are significantly related to ICP. This observation suggests that the method could be valuable, in addition to continuous monitoring, also for early warning in emergency medicine and critical care units.
Manigandan, Durai; Karrthick, Karukkupalayam Palaniappan; Sambasivaselli, Raju; Senniandavar, Vellaingiri; Ramu, Mahendran; Rajesh, Thiyagarajan; Lutz, Muller; Muthukumaran, Manavalan; Karthikeyan, Nithyanantham; Tejinder, Kataria
2014-01-01
The purpose of this study was to evaluate quantitatively the patient‐specific 3D dosimetry tool COMPASS with 2D array MatriXX detector for stereotactic volumetric‐modulated arc delivery. Twenty‐five patients CT images and RT structures from different sites (brain, head & neck, thorax, abdomen, and spine) were taken from CyberKnife Multiplan planning system for this study. All these patients underwent radical stereotactic treatment in CyberKnife. For each patient, linac based volumetric‐modulated arc therapy (VMAT) stereotactic plans were generated in Monaco TPS v3.1 using Elekta Beam Modulator MLC. Dose prescription was in the range of 5–20 Gy per fraction. Target prescription and critical organ constraints were tried to match the delivered treatment plans. Each plan quality was analyzed using conformity index (CI), conformity number (CN), gradient Index (GI), target coverage (TC), and dose to 95% of volume (D95). Monaco Monte Carlo (MC)‐calculated treatment plan delivery accuracy was quantitatively evaluated with COMPASS‐calculated (CCA) dose and COMPASS indirectly measured (CME) dose based on dose‐volume histogram metrics. In order to ascertain the potential of COMPASS 3D dosimetry for stereotactic plan delivery, 2D fluence verification was performed with MatriXX using MultiCube phantom. Routine quality assurance of absolute point dose verification was performed to check the overall delivery accuracy. Quantitative analyses of dose delivery verification were compared with pass and fail criteria of 3 mm and 3% distance to agreement and dose differences. Gamma passing rate was compared with 2D fluence verification from MatriXX with MultiCube. Comparison of COMPASS reconstructed dose from measured fluence and COMPASS computed dose has shown a very good agreement with TPS calculated dose. Each plan was evaluated based on dose volume parameters for target volumes such as dose at 95% of volume (D95) and average dose. For critical organs dose at 20% of volume (D20), dose at 50% of volume (D50), and maximum point doses were evaluated. Comparison was carried out using gamma analysis with passing criteria of 3 mm and 3%. Mean deviation of 1.9%±1% was observed for dose at 95% of volume (D95) of target volumes, whereas much less difference was noticed for critical organs. However, significant dose difference was noticed in two cases due to the smaller tumor size. Evaluation of this study revealed that the COMPASS 3D dosimetry is efficient and easy to use for patient‐specific QA of VMAT stereotactic delivery. 3D dosimetric QA with COMPASS provides additional degrees of freedom to check the high‐dose modulated stereotactic delivery with very high precision on patient CT images. PACS numbers: 87.55.Qr, 87.56.Fc PMID:25679152
Accumulated Delivered Dose Response of Stereotactic Body Radiation Therapy for Liver Metastases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swaminath, Anand; Massey, Christine; Brierley, James D.
2015-11-01
Purpose: To determine whether the accumulated dose using image guided radiation therapy is a stronger predictor of clinical outcomes than the planned dose in stereotactic body radiation therapy (SBRT) for liver metastases. Methods and Materials: From 2003 to 2009, 81 patients with 142 metastases were treated in institutional review board–approved SBRT studies (5-10 fractions). Patients were treated during free breathing (with or without abdominal compression) or with controlled exhale breath-holding. SBRT was planned on a static exhale computed tomography (CT) scan, and the minimum planning target volume dose to 0.5 cm{sup 3} (minPTV) was recorded. The accumulated minimum dose to themore » 0.5 cm{sup 3} gross tumor volume (accGTV) was calculated after performing dose accumulation from exported image guided radiation therapy data sets registered to the planning CT using rigid (2-dimensional MV/kV orthogonal) or deformable (3-dimensional/4-dimensional cone beam CT) image registration. Univariate and multivariate Cox regression models assessed the factors influencing the time to local progression (TTLP). Hazard ratios for accGTV and minPTV were compared using model goodness-of-fit and bootstrapping. Results: Overall, the accGTV dose exceeded the minPTV dose in 98% of the lesions. For 5 to 6 fractions, accGTV doses of >45 Gy were associated with 1-year local control of 86%. On univariate analysis, the cancer subtype (breast), smaller tumor volume, and increased dose were significant predictors for improved TTLP. The dose and volume were uncorrelated; the accGTV dose and minPTV dose were correlated and were tested separately on multivariate models. Breast cancer subtype, accGTV dose (P<.001), and minPTV dose (P=.02) retained significance in the multivariate models. The univariate hazard ratio for TTLP for 5-Gy increases in accGTV versus minPTV was 0.67 versus 0.74 (all patients; 95% confidence interval of difference 0.03-0.14). Goodness-of-fit testing confirmed the accGTV dose as a stronger dose–response predictor than the minPTV dose. Conclusions: The accGTV dose is a better predictor of TTLP than the minPTV dose for liver metastasis SBRT. The use of modern image guided radiation therapy in future analyses of dose–response outcomes should increase the concordance between the planned and delivered doses.« less
Stera, Susanne; Balermpas, Panagiotis; Chan, Mark K H; Huttenlocher, Stefan; Wurster, Stefan; Keller, Christian; Imhoff, Detlef; Rades, Dirk; Dunst, Jürgen; Rödel, Claus; Hildebrandt, Guido; Blanck, Oliver
2018-02-01
We retrospectively evaluated the patterns of failure for robotic guided real-time breathing-motion-compensated (BMC) stereotactic body radiation therapy (SBRT) in the treatment of tumors in moving organs. Between 2011 and 2016, a total of 198 patients with 280 lung, liver, and abdominal tumors were treated with BMC-SBRT. The median gross tumor volume (GTV) was 12.3 cc (0.1-372.0 cc). Medians of mean GTV BED α/β = 10 Gy (BED = biological effective dose) was 148.5 Gy 10 (31.5-233.3 Gy 10 ) and prescribed planning target volume (PTV) BED α/β = 10 Gy was 89.7 Gy 10 (28.8-151.2 Gy 10 ), respectively. We analyzed overall survival (OS) and local control (LC) based on various factors, including BEDs with α/β ratios of 15 Gy (lung metastases), 21 Gy (primary lung tumors), and 27 Gy (liver metastases). Median follow-up was 10.4 months (2.0-59.0 months). The 2‑year actuarial LC was 100 and 86.4% for primary early and advanced stage lung tumors, respectively, 100% for lung metastases, 82.2% for liver metastases, and 90% for extrapulmonary extrahepatic metastases. The 2‑year OS rate was 47.9% for all patients. In uni- and multivariate analysis, comparatively lower PTV prescription dose (equivalence of 3 × 12-13 Gy) and higher average GTV dose (equivalence of 3 × 18 Gy) to current practice were significantly associated with LC. For OS, Karnofsky performance score (100%), gender (female), and SBRT without simultaneous chemotherapy were significant prognostic factors. Grade 3 side effects were rare (0.5%). Robotic guided BMC-SBRT can be considered a safe and effective treatment for solid tumors in moving organs. To reach sufficient local control rates, high average GTV doses are necessary. Further prospective studies are warranted to evaluate these points.
NASA Astrophysics Data System (ADS)
Stemkens, Bjorn; Glitzner, Markus; Kontaxis, Charis; de Senneville, Baudouin Denis; Prins, Fieke M.; Crijns, Sjoerd P. M.; Kerkmeijer, Linda G. W.; Lagendijk, Jan J. W.; van den Berg, Cornelis A. T.; Tijssen, Rob H. N.
2017-09-01
Stereotactic body radiation therapy (SBRT) has shown great promise in increasing local control rates for renal-cell carcinoma (RCC). Characterized by steep dose gradients and high fraction doses, these hypo-fractionated treatments are, however, prone to dosimetric errors as a result of variations in intra-fraction respiratory-induced motion, such as drifts and amplitude alterations. This may lead to significant variations in the deposited dose. This study aims to develop a method for calculating the accumulated dose for MRI-guided SBRT of RCC in the presence of intra-fraction respiratory variations and determine the effect of such variations on the deposited dose. For this, RCC SBRT treatments were simulated while the underlying anatomy was moving, based on motion information from three motion models with increasing complexity: (1) STATIC, in which static anatomy was assumed, (2) AVG-RESP, in which 4D-MRI phase-volumes were time-weighted, and (3) PCA, a method that generates 3D volumes with sufficient spatio-temporal resolution to capture respiration and intra-fraction variations. Five RCC patients and two volunteers were included and treatments delivery was simulated, using motion derived from subject-specific MR imaging. Motion was most accurately estimated using the PCA method with root-mean-squared errors of 2.7, 2.4, 1.0 mm for STATIC, AVG-RESP and PCA, respectively. The heterogeneous patient group demonstrated relatively large dosimetric differences between the STATIC and AVG-RESP, and the PCA reconstructed dose maps, with hotspots up to 40% of the D99 and an underdosed GTV in three out of the five patients. This shows the potential importance of including intra-fraction motion variations in dose calculations.
Zhang, Yunyun; Yan, Jing; Fu, Yi; Chen, Shengdi
2013-01-01
Objective To compare the accuracy of formula 1/2ABC with 2/3SH on volume estimation for hypertensive infratentorial hematoma. Methods One hundred and forty-seven CT scans diagnosed as hypertensive infratentorial hemorrhage were reviewed. Based on the shape, hematomas were categorized as regular or irregular. Multilobular was defined as a special shape of irregular. Hematoma volume was calculated employing computer-assisted volumetric analysis (CAVA), 1/2ABC and 2/3SH, respectively. Results The correlation coefficients between 1/2ABC (or 2/3SH) and CAVA were greater than 0.900 in all subgroups. There were neither significant differences in absolute values of volume deviation nor percentage deviation between 1/2ABC and 2/3SH for regular hemorrhage (P>0.05). While for cerebellar, brainstem and irregular hemorrhages, the absolute values of volume deviation and percentage deviation by formula 1/2ABC were greater than 2/3SH (P<0.05). 1/2ABC and 2/3SH underestimated hematoma volume each by 10% and 5% for cerebellar hemorrhage, 14% and 9% for brainstem hemorrhage, 19% and 16% for regular hemorrhage, 9% and 3% for irregular hemorrhage, respectively. In addition, for the multilobular hemorrhage, 1/2ABC underestimated the volume by 9% while 2/3SH overestimated it by 2%. Conclusions For regular hemorrhage volume calculation, the accuracy of 2/3SH is similar to 1/2ABC. While for cerebellar, brainstem or irregular hemorrhages (including multilobular), 2/3SH is more accurate than 1/2ABC. PMID:23638025
Optical spectroscopy for stereotactic biopsy of brain tumors
NASA Astrophysics Data System (ADS)
Markwardt, Niklas; von Berg, Anna; Fiedler, Sebastian; Goetz, Marcus; Haj-Hosseini, Neda; Polzer, Christoph; Stepp, Herbert; Zelenkov, Petr; Rühm, Adrian
2015-07-01
Stereotactic biopsy procedure is performed to obtain a tissue sample for diagnosis purposes. Currently, a fiber-based mechano-optical device for stereotactic biopsies of brain tumors is developed. Two different fluorophores are employed to improve the safety and reliability of this procedure: The fluorescence of intravenously applied indocyanine green (ICG) facilitates the recognition of blood vessels and thus helps minimize the risk of cerebral hemorrhages. 5- aminolevulinic-acid-induced protoporphyrin IX (PpIX) fluorescence is used to localize vital tumor tissue. ICG fluorescence detection using a 2-fiber probe turned out to be an applicable method to recognize blood vessels about 1.5 mm ahead of the fiber tip during a brain tumor biopsy. Moreover, the suitability of two different PpIX excitation wavelengths regarding practical aspects was investigated: While PpIX excitation in the violet region (at 405 nm) allows for higher sensitivity, red excitation (at 633 nm) is noticeably superior with regard to blood layers obscuring the fluorescence signal. Contact measurements on brain simulating agar phantoms demonstrated that a typical blood coverage of the tumor reduces the PpIX signal to about 75% and nearly 0% for 633 nm and 405 nm excitation, respectively. As a result, 633 nm seems to be the wavelength of choice for PpIX-assisted detection of high-grade gliomas in stereotactic biopsy.
Salvage Reirradiaton With Stereotactic Body Radiotherapy for Locally Recurrent Head-and-Neck Tumors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cengiz, Mustafa, E-mail: mcengiz@hacettepe.edu.tr; Ozyigit, Goekhan; Yazici, Goezde
2011-09-01
Purpose: In this study, we present our results of reirradiation of locally recurrent head-and-neck cancer with image-guided, fractionated, frameless stereotactic body radiotherapy technique. Methods and Materials: From July 2007 to February 2009, 46 patients were treated using the CyberKnife (Accuray, Sunnyvale, CA) at the Department of Radiation Oncology, Hacettepe University, Ankara, Turkey. All patients had recurrent, unresectable, and previously irradiated head-and-neck cancer. The most prominent site was the nasopharynx (32.6%), and the most common histopathology was epidermoid carcinoma. The planning target volume was defined as the gross tumor volume identified on magnetic resonance imaging and computed tomography. There were 22more » female and 24 male patients. Median age was 53 years (range, 19-87 years). The median tumor dose with stereotactic body radiotherapy was 30 Gy (range, 18-35 Gy) in a median of five (range, one to five) fractions. Results: Of 37 patients whose response to therapy was evaluated, 10 patients (27%) had complete tumor regression, 11 (29.8%) had partial response, and 10 (27%) had stable disease. Ultimate local disease control was achieved in 31 patients (83.8%). The overall survival was 11.93 months in median (ranged, 11.4 - 17.4 months), and the median progression free survival was 10.5 months. One-year progression-free survival and overall survival were 41% and 46%, respectively. Grade II or greater long-term complications were observed in 6 (13.3%) patients. On follow-up, 8 (17.3%) patients had carotid blow-out syndrome, and 7 (15.2%) patients died of bleeding from carotid arteries. We discovered that this fatal syndrome occurred only in patients with tumor surrounding carotid arteries and carotid arteries receiving all prescribed dose. Conclusions: Stereotactic body radiotherapy is an appealing treatment option for patients with recurrent head-and-neck cancer previously treated with radiation to high doses. Good local control with considerable 1-year survival is achieved with a relatively high rate of morbidity and related mortality.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.
1989-12-01
Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinicalmore » and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig.« less
Manjila, Sunil; Knudson, Kathleen E; Johnson, Carleton; Sloan, Andrew E
2016-06-01
Stereotactic biopsy is an important and minimally invasive technique used for a variety of indications in neurosurgery. Initially, this technique required a frame, but recently there have been a number of newer, less cumbersome approaches to biopsy including robotic arms, fixed arms, and, more recently, skull-mounted miniframes. Miniframes are attractive because they are disposable and low profile. However, the relatively limited degree of freedom offered by currently available devices necessitates a preplanned burr hole, which in turn limits flexibility and multiple trajectories. The AXiiiS device is a skull-mounted, magnetic resonance imaging-compatible miniframe that provides a similar degree of freedom with a frame while maintaining a low-profile, disposable platform. To assess the image-guided trajectory alignment accuracy using AXiiiS stereotactic miniframe biopsy of intracranial lesions. The accuracy of the AXiiiS device is compared with the Navigus Trajectory Guide as platforms. After approval by our institutional review board, medical records of 10 neurosurgical patients with intracranial pathologies were chosen for AXiiiS stereotactic miniframe biopsy, and histological correlation was obtained. Ten reported cases demonstrate the precision and ease of using the AXiiiS stereotactic miniframe for biopsy of intracranial lesions in conjunction with preoperative magnetic resonance imaging. Multiple trajectories and angles have been used with precision and safety. The AXiiiS stereotactic miniframe is a feasible, safe, and disposable platform for multitrajectory intracranial biopsies. Compared with existing platforms, this novel device provides a more stable base and wider limits of trajectory angles with comparable accuracy and precision.
Lung tumor motion change during stereotactic body radiotherapy (SBRT): an evaluation using MRI
Olivier, Kenneth R.; Li, Jonathan G.; Liu, Chihray; Newlin, Heather E.; Schmalfuss, Ilona; Kyogoku, Shinsuke; Dempsey, James F.
2014-01-01
The purpose of this study is to investigate changes in lung tumor internal target volume during stereotactic body radiotherapy treatment (SBRT) using magnetic resonance imaging (MRI). Ten lung cancer patients (13 tumors) undergoing SBRT (48 Gy over four consecutive days) were evaluated. Each patient underwent three lung MRI evaluations: before SBRT (MRI‐1), after fraction 3 of SBRT (MRI‐3), and three months after completion of SBRT (MRI‐3m). Each MRI consisted of T1‐weighted images in axial plane through the entire lung. A cone‐beam CT (CBCT) was taken before each fraction. On MRI and CBCT taken before fractions 1 and 3, gross tumor volume (GTV) was contoured and differences between the two volumes were compared. Median tumor size on CBCT before fractions 1 (CBCT‐1) and 3 (CBCT‐3) was 8.68 and 11.10 cm3, respectively. In 12 tumors, the GTV was larger on CBCT‐3 compared to CBCT‐1 (median enlargement, 1.56 cm3). Median tumor size on MRI‐1, MRI‐3, and MRI‐3m was 7.91, 11.60, and 3.33 cm3, respectively. In all patients, the GTV was larger on MRI‐3 compared to MRI‐1 (median enlargement, 1.54 cm3). In all patients, GTV was smaller on MRI‐3m compared to MRI‐1 (median shrinkage, 5.44 cm3). On CBCT and MRI, all patients showed enlargement of the GTV during the treatment week of SBRT, except for one patient who showed minimal shrinkage (0.86 cm3). Changes in tumor volume are unpredictable; therefore, motion and breathing must be taken into account during treatment planning, and image‐guided methods should be used, when treating with large fraction sizes. PACS number: 87.53.Ly PMID:24892328
Charged-particle stereotactic radiosurgery
NASA Astrophysics Data System (ADS)
Lyman, John T.; Fabrikant, Jacob I.; Frankel, Kenneth A.
1985-05-01
Charged-particle stereotactic radiosurgery is the technique of using accelerated atomic nuclei for the irradiation of a small volume target to a high dose in a short time interval. This is contrasted with conventional radiotherapy where large volumes are treated with many small fractions of photon or electron radiation over a multi-week period. The helium-ion beam used for charged-particle stereotactic radiosurgery at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron is described. This beam is being used for the treatment of inoperable, deep, intracranial arteriovenous malformations (AVMs). Intracranial AVMs are collections of abnormal blood vessels in the brain that may represent a failure of vessels to mature properly and after a long period of slow growth they may produce clinically recognizable neurological symptoms. Based on our experience using narrow beams of helium ions for stereotactic radiosurgical treatment of AVM patients, the characteristics of the treatments are described. Improvements to the technique which are possible by the use of other charged particle beams are discussed.
Safain, Mina G.; Rahal, Jason P.; Raval, Ami; Rivard, Mark J.; Mignano, John; Wu, Julian; Malek, Adel M.
2014-01-01
Background The effectiveness of Gamma Knife radiosurgery (GKR) for cerebral arteriovenous malformations (AVM) is predicated on inclusion of the entire nidus while excluding normal tissue. As such, GKR may be limited by the resolution and accuracy of the imaging modality used in targeting. Objective We present the first case series to demonstrate the feasibility of utilizing ultra-high-resolution C-arm cone beam computed tomography angiography (CBCT-A) in AVM targeting. Methods From June 2009 to June 2013, CBCT-A was utilized for targeting of all patients with AVMs treated with GKR at our institution. Patients underwent Leksell stereotactic head frame placement followed by catheter-based biplane 2-D digital subtraction angiography (DSA), 3-D rotational angiography (3DRA), as well as CBCT-A. The CBCT-A dataset was used for stereotactic planning for GKR. Patients were followed up at 1, 3, 6, and 12 months, and then annually thereafter. Results CBCT-A-based targeting was used in twenty-two consecutive patients. CBCT-A provided detailed spatial resolution and sensitivity of nidal angioarchitecture enabling treatment. The average radiation dose to the margin of the AVM nidus corresponding to the 50% percent isodose line was 15.6 Gy. No patient had treatment-associated hemorrhage. At early follow-up (mean=16 months), 84% of patients had a decreasing or obliterated AVM nidus. Conclusion CBCT-A-guided radiosurgery is feasible and useful because it provides sufficient detailed resolution and sensitivity for imaging brain AVMs. PMID:24584136
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milano, Michael T.; Katz, Alan W.; Schell, Michael C.
Purpose: To characterize oligometastases in patients enrolled on two prospective pilot studies, treating oligometastases with hypofractionated stereotactic body radiotherapy and stereotactic radiosurgery to cranial lesions. Methods and Materials: We describe the characteristics and local control (LC) of 293 lesions in 121 patients with five or fewer metastases treated with stereotactic body radiation and/or cranial stereotactic radiosurgery. For each lesion, the primary cancer site, tumor histology, site of metastasis, gross tumor volume, and prescribed dose were ascertained. The prescribed dose is expressed by the biologically effective dose in 2-Gy fractions (BED2), calculated using the linear quadratic model, assuming an {alpha}/{beta} ratiomore » of 10. Results: Lung lesions were significantly smaller than other lesions in our cohort, whereas liver lesions were significantly larger, possibly reflecting a detection and/or referral bias. The 2-year and 4-year tumor LC rates were 77% and 73% respectively. A larger gross tumor volume was significantly (p < 0.0001) correlated with worse lesion LC. Lesions originating from primary pancreatic, biliary or liver cancer exhibited significantly poorer LC, as did lesions from colorectal cancer. Lesions from breast cancer were better controlled. A higher BED2 did not correlate with improved tumor control. Conclusions: Stereotactic body radiation to aggressively treat oligometastatic lesions results in good local tumor control. Bulkier lesions are more difficult to control and may benefit from dose escalation.« less
Okamura, Koichi; Tsubokawa, Tamiji; Johshita, Hiroo; Miyazaki, Hiroshi; Shiokawa, Yoshiaki
2014-01-01
Thrombolysis due to acute ischemic stroke is associated with the risk of hemorrhagic infarction, especially after reperfusion. Recent experimental studies suggest that the main mechanism contributing to hemorrhagic infarction is oxidative stress caused by disruption of the blood-brain barrier. Edaravone, a free radical scavenger, decreases oxidative stress, thereby preventing hemorrhagic infarction during ischemia and reperfusion. In this study, we investigated the effects of edaravone on hemorrhagic infarction in a rat model of hemorrhagic transformation. We used a previously established hemorrhagic transformation model of rats with hyperglycemia. Hyperglycemia was induced by intraperitoneal injection of glucose to all rats (n = 20). The rats with hyperglycemia showed a high incidence of hemorrhagic infarction. Middle cerebral artery occlusion (MCAO) for 1.5 hours followed by reperfusion for 24 hours was performed in edaravone-treated rats (n = 10) and control rats (n = 10). Upon completion of reperfusion, both groups were evaluated for infarct size and hemorrhage volume and the results obtained were compared. Edaravone significantly decreased infarct volume, with the average infarct volume in the edaravone-treated rats (227.6 mm(3)) being significantly lower than that in the control rats (264.0 mm(3)). Edaravone treatment also decreased the postischemic hemorrhage volumes (53.4 mm(3) in edaravone-treated rats vs 176.4 mm(3) in controls). In addition, the ratio of hemorrhage volume to infarct volume was lower in the edaravone-treated rats (23.5%) than in the untreated rats (63.2%). Edaravone attenuates cerebral infarction and hemorrhagic infarction in rats with hyperglycemia.
AlDahlawi, Ismail; Prasad, Dheerendra; Podgorsak, Matthew B
2017-05-01
The Gamma Knife Icon comes with an integrated cone-beam CT (CBCT) for image-guided stereotactic treatment deliveries. The CBCT can be used for defining the Leksell stereotactic space using imaging without the need for the traditional invasive frame system, and this allows also for frameless thermoplastic mask stereotactic treatments (single or fractionated) with the Gamma Knife unit. In this study, we used an in-house built marker tool to evaluate the stability of the CBCT-based stereotactic space and its agreement with the standard frame-based stereotactic space. We imaged the tool with a CT indicator box using our CT-simulator at the beginning, middle, and end of the study period (6 weeks) for determining the frame-based stereotactic space. The tool was also scanned with the Icon's CBCT on a daily basis throughout the study period, and the CBCT images were used for determining the CBCT-based stereotactic space. The coordinates of each marker were determined in each CT and CBCT scan using the Leksell GammaPlan treatment planning software. The magnitudes of vector difference between the means of each marker in frame-based and CBCT-based stereotactic space ranged from 0.21 to 0.33 mm, indicating good agreement of CBCT-based and frame-based stereotactic space definition. Scanning 4-month later showed good prolonged stability of the CBCT-based stereotactic space definition. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jia, J; Tian, Z; Gu, X
Purpose: To investigate the dosimetric benefit of adaptive re-planning for lung stereotactic body radiotherapy(SBRT). Methods: Five lung cancer patients with SBRT treatment were retrospectively investigated. Our in-house supercomputing online re-planning environment (SCORE) was used to realize the re-planning process. First a deformable image registration was carried out to transfer contours from treatment planning CT to each treatment CBCT. Then an automatic re-planning using original plan DVH guided fluence-map optimization is performed to get a new plan for the up-to-date patient geometry. We compared the re-optimized plan to the original plan projected on the up-to-date patient geometry in critical dosimetric parameters,more » such as PTV coverage, spinal cord maximum and volumetric constraint dose, esophagus maximum and volumetric constraint dose. Results: The average volume of PTV covered by prescription dose for all patients was improved by 7.56% after the adaptive re-planning. The volume of the spinal cord receiving 14.5Gy and 23Gy (V14.5, V23) decreased by 1.48% and 0.68%, respectively. For the esophagus, the volume receiving 19.5Gy (V19.5) reduced by 1.37%. Meanwhile, the maximum dose dropped off by 2.87% for spinal cord and 4.80% for esophagus. Conclusion: Our experimental results demonstrate that adaptive re-planning for lung SBRT has the potential to minimize the dosimetric effect of inter-fraction deformation and thus improve target coverage while reducing the risk of toxicity to nearby normal tissues.« less
Molina, H; Quiñones, R; Ortega, I; Alvarez, L; Muñoz, J; Gonzalez, C; Suárez, C
1993-01-01
We report our preliminary results related to CT-guided stereotactic transplantation of foetal ventral mesencephalic cell suspension into the striatum of five patients with idiopathic Parkinson's disease. The mean age was 51 years, the evolution time of the disease ranged from 7 to 14 years, and all of them had motor complications associated with chronic L-dopa therapy. The patients were evaluated according to the Core Assessment Program for Intracerebral Transplantations (CAPIT) for one year before and three months after surgery. The postoperative clinical assessment demonstrated significant improvement of neurological symptoms and reduction of daily L-dopa dosage.
LaRiviere, Michael J.; Gross, Robert E.
2016-01-01
Epilepsy is a common, disabling illness that is refractory to medical treatment in approximately one-third of patients, particularly among those with mesial temporal lobe epilepsy. While standard open mesial temporal resection is effective, achieving seizure freedom in most patients, efforts to develop safer, minimally invasive techniques have been underway for over half a century. Stereotactic ablative techniques, in particular, radiofrequency (RF) ablation, were first developed in the 1960s, with refinements in the 1990s with the advent of modern computed tomography and magnetic resonance-based imaging. In the past 5 years, the most recent techniques have used MRI-guided laser interstitial thermotherapy (LITT), the development of which began in the 1980s, saw refinements in MRI thermal imaging through the 1990s, and was initially used primarily for the treatment of intracranial and extracranial tumors. The present review describes the original stereotactic ablation trials, followed by modern imaging-guided RF ablation series for mesial temporal lobe epilepsy. The developments of LITT and MRI thermometry are then discussed. Finally, the two currently available MRI-guided LITT systems are reviewed for their role in the treatment of mesial temporal lobe and other medically refractory epilepsies. PMID:27995127
Lu, Yi; Yeung, Cecil; Radmanesh, Alireza; Wiemann, Robert; Black, Peter M.; Golby, Alexandra J.
2015-01-01
Objective Intraoperative MRI (IoMRI) guided brain biopsy provides a real time visual feedback of the lesion that is sampled during surgery. The objective of the study is to compare the diagnostic yield and safety profiles of ioMRI needle brain biopsy with two traditional brain biopsy methods: frame-based and frameless stereotactic brain biopsies. Methods A retrospective analysis from 288 consecutive needle brain biopsies in 277 patients undergoing stereotactic brain biopsy with any of the three biopsy methods at Brigham and Women's Hospital from 2000 to 2008 was performed. Variables such as age, sex, history of radiation and previous surgery, pathology results, complications and postoperative stays were analyzed. Results Over the course of eight years, 288 brain biopsies were performed. 253 (87.8%) biopsies yielded positive diagnostic tissue. Young age (<40 years), history of brain radiation or surgery were significant negative predictors for a positive biopsy diagnostic yield. Excluding patients with prior radiation or surgeries, no significant difference in diagnostic yield was detected among the three groups, with frame-based, frameless and ioMRI guided needle biopsies yield 96.9%, 91.8% and 89.9% positive diagnostic yield, respectively. 19 biopsies (6.6%) were complicated by serious adverse events. The ioMRI-guided brain biopsy was associated with less serious adverse events and the shortest postoperative hospital stay. Conclusions Frame-based, frameless stereotactic and ioMRI guided brain needle biopsy have comparable diagnostic yield for patients with no prior treatments (either radiation or surgery). IoMRI guided brain biopsy is associated with fewer serious adverse events and shorter hospital stay. PMID:25088233
Hematoma Expansion Following Acute Intracerebral Hemorrhage
Brouwers, H. Bart; Greenberg, Steven M.
2013-01-01
Intracerebral hemorrhage, the most devastating form of stroke, has no specific therapy proven to improve outcome by randomized controlled trial. Location and baseline hematoma volume are strong predictors of mortality, but are non-modifiable by the time of diagnosis. Expansion of the initial hematoma is a further marker of poor prognosis that may be at least partly preventable. Several risk factors for hematoma expansion have been identified, including baseline ICH volume, early presentation after symptom onset, anticoagulation, and the CT angiography spot sign. Although the biological mechanisms of hematoma expansion remain unclear, accumulating evidence supports a model of ongoing secondary bleeding from ruptured adjacent vessels surrounding the initial bleeding site. Several large clinical trials testing therapies aimed at preventing hematoma expansion are in progress, including aggressive blood pressure reduction, treatment with recombinant factor VIIa guided by CT angiography findings, and surgical intervention for superficial hematomas without intraventricular extension. Hematoma expansion is so far the only marker of outcome that is amenable to treatment and thus a potentially important therapeutic target. PMID:23466430
Restoration of the ascending reticular activating system compressed by hematoma in a stroke patient
Jang, Sung Ho; Seo, Jeong Pyo
2017-01-01
Abstract Rationale: We report on restoration of the ascending reticular activating system (ARAS), compressed by an intracerebral hematoma and perihematomal edema following a stroke. The restoration of the ARAS was demonstrated by diffusion tensor tractography (DTT). Patient concerns: In a 60-year-old male, a brain MRI taken at 2 weeks after the surgery showed a hematoma and perihematomal edema in the left posterolateral pons and cerebellum, which were markedly resolved on a brain MRI after 5 weeks. Diagnoses: Intraventricular hemorrhage. Interventions: Navigation-guided stereotactic drainage of a hematoma in the left cerebellum, comprehensive rehabilitative therapy, including hypersomnia medication (modafinil), physical therapy, and occupational therapy. Outcomes: His hypersomnia improved significantly with rehabilitation, with no daytime hypersomnia beginning 3 weeks after the surgery. On 2-week DTT, neither the neural tract of the left lower dorsal or ventral ARAS were reconstructed, but these neural tracts were wellreconstructed on 5-week DTT. Lessons: In conclusion, restoration of nonreconstructed neural tracts of the lower ARAS with the resolution of the hematoma and perihematomal edema was demonstrated in a stroke patient, using DTT. PMID:28207526
NASA Astrophysics Data System (ADS)
Zamorano, Lucia J.; Dujovny, Manuel; Ausman, James I.
1990-01-01
"Real time" surgical treatment planning utilizing multimodality imaging (CT, MRI, DA) has been developed to provide the neurosurgeon with 2D multiplanar and 3D views of a patient's lesion for stereotactic planning. Both diagnostic and therapeutic stereotactic procedures have been implemented utilizing workstation (SUN 1/10) and specially developed software and hardware (developed in collaboration with TOMO Medical Imaging Technology, Southfield, MI). This provides complete 3D and 2D free-tilt views as part of the system instrumentation. The 2D Multiplanar includes reformatted sagittal, coronal, paraaxial and free tilt oblique vectors at any arbitrary plane of the patient's lesion. The 3D includes features for extracting a view of the target volume localized by a process including steps of automatic segmentation, thresholding, and/or boundary detection with 3D display of the volumes of interest. The system also includes the capability of interactive playback of reconstructed 3D movies, which can be viewed at any hospital network having compatible software on strategical locations or at remote sites through data transmission and record documentation by image printers. Both 2D and 3D menus include real time stereotactic coordinate measurements and trajectory definition capabilities as well as statistical functions for computing distances, angles, areas, and volumes. A combined interactive 3D-2D multiplanar menu allows simultaneous display of selected trajectory, final optimization, and multiformat 2D display of free-tilt reformatted images perpendicular to selected trajectory of the entire target volume.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clements, N.; Kron, T.; Roxby, P.
2013-02-15
Purpose: Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning the tumor to the planning 4DCT MIP ITV contour. Moving targets imaged with CBCT can appear blurred and currently there are no studies reporting on the effect that irregular breathing patterns have on CBCT volumes and their alignment to 4DCT MIP ITV contours. The objective of thismore » work was therefore to image a phantom moving with irregular breathing patterns to determine whether any configurations resulted in errors in volume contouring or alignment. Methods: A Perspex thorax phantom was used to simulate a patient. Three wooden 'lung' inserts with embedded Perspex 'lesions' were moved up to 4 cm with computer-generated motion patterns, and up to 1 cm with patient-specific breathing patterns. The phantom was imaged on 4DCT and CBCT with the same acquisition settings used for stereotactic lung patients in the clinic and the volumes on all phantom images were contoured. This project assessed the volumes for qualitative and quantitative changes including volume, length of the volume, and errors in alignment between CBCT volumes and 4DCT MIP ITV contours. Results: When motion was introduced 4DCT and CBCT volumes were reduced by up to 20% and 30% and shortened by up to 7 and 11 mm, respectively, indicating that volume was being under-represented at the extremes of motion. Banding artifacts were present in 4DCT MIP images, while CBCT volumes were largely reduced in contrast. When variable amplitudes from patient traces were used and CBCT ITVs were compared to 4DCT MIP ITVs there was a distinct trend in reduced ITV with increasing amplitude that was not seen when compared to true ITVs. Breathing patterns with a rest period following expiration resulted in well-defined superior edges and were better aligned using an edge-to-edge alignment technique. In most cases, sinusoidal motion patterns resulted in the closest agreements to true values and the smallest misalignments. Conclusions: Strategies are needed to compensate for volume losses at the extremes of motion for both 4DCT MIP and CBCT images for larger and varied amplitudes, and for patterns with rest periods following expiration. Lesions moving greater than 2 cm would warrant larger treatment margins added to the 4DCT MIP ITV to account for the volume being under-represented at the extremes of motion. Lesions moving with a rest period following expiration would be better aligned using an edge-to-edge alignment technique. Sinusoidal patterns represented the ideal clinical scenario, reinforcing the importance of investigating clinically relevant motions and their effects on 4DCT MIP and CBCT volumes. Since most patients do not breathe sinusoidally this may lead to misinterpretation of previous studies using only sinusoidal motion.« less
Clements, N; Kron, T; Franich, R; Dunn, L; Roxby, P; Aarons, Y; Chesson, B; Siva, S; Duplan, D; Ball, D
2013-02-01
Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning the tumor to the planning 4DCT MIP ITV contour. Moving targets imaged with CBCT can appear blurred and currently there are no studies reporting on the effect that irregular breathing patterns have on CBCT volumes and their alignment to 4DCT MIP ITV contours. The objective of this work was therefore to image a phantom moving with irregular breathing patterns to determine whether any configurations resulted in errors in volume contouring or alignment. A Perspex thorax phantom was used to simulate a patient. Three wooden "lung" inserts with embedded Perspex "lesions" were moved up to 4 cm with computer-generated motion patterns, and up to 1 cm with patient-specific breathing patterns. The phantom was imaged on 4DCT and CBCT with the same acquisition settings used for stereotactic lung patients in the clinic and the volumes on all phantom images were contoured. This project assessed the volumes for qualitative and quantitative changes including volume, length of the volume, and errors in alignment between CBCT volumes and 4DCT MIP ITV contours. When motion was introduced 4DCT and CBCT volumes were reduced by up to 20% and 30% and shortened by up to 7 and 11 mm, respectively, indicating that volume was being under-represented at the extremes of motion. Banding artifacts were present in 4DCT MIP images, while CBCT volumes were largely reduced in contrast. When variable amplitudes from patient traces were used and CBCT ITVs were compared to 4DCT MIP ITVs there was a distinct trend in reduced ITV with increasing amplitude that was not seen when compared to true ITVs. Breathing patterns with a rest period following expiration resulted in well-defined superior edges and were better aligned using an edge-to-edge alignment technique. In most cases, sinusoidal motion patterns resulted in the closest agreements to true values and the smallest misalignments. Strategies are needed to compensate for volume losses at the extremes of motion for both 4DCT MIP and CBCT images for larger and varied amplitudes, and for patterns with rest periods following expiration. Lesions moving greater than 2 cm would warrant larger treatment margins added to the 4DCT MIP ITV to account for the volume being under-represented at the extremes of motion. Lesions moving with a rest period following expiration would be better aligned using an edge-to-edge alignment technique. Sinusoidal patterns represented the ideal clinical scenario, reinforcing the importance of investigating clinically relevant motions and their effects on 4DCT MIP and CBCT volumes. Since most patients do not breathe sinusoidally this may lead to misinterpretation of previous studies using only sinusoidal motion.
Developing and implementing a high precision setup system
NASA Astrophysics Data System (ADS)
Peng, Lee-Cheng
The demand for high-precision radiotherapy (HPRT) was first implemented in stereotactic radiosurgery using a rigid, invasive stereotactic head frame. Fractionated stereotactic radiotherapy (SRT) with a frameless device was developed along a growing interest in sophisticated treatment with a tight margin and high-dose gradient. This dissertation establishes the complete management for HPRT in the process of frameless SRT, including image-guided localization, immobilization, and dose evaluation. The most ideal and precise positioning system can allow for ease of relocation, real-time patient movement assessment, high accuracy, and no additional dose in daily use. A new image-guided stereotactic positioning system (IGSPS), the Align RT3C 3D surface camera system (ART, VisionRT), which combines 3D surface images and uses a real-time tracking technique, was developed to ensure accurate positioning at the first place. The uncertainties of current optical tracking system, which causes patient discomfort due to additional bite plates using the dental impression technique and external markers, are found. The accuracy and feasibility of ART is validated by comparisons with the optical tracking and cone-beam computed tomography (CBCT) systems. Additionally, an effective daily quality assurance (QA) program for the linear accelerator and multiple IGSPSs is the most important factor to ensure system performance in daily use. Currently, systematic errors from the phantom variety and long measurement time caused by switching phantoms were discovered. We investigated the use of a commercially available daily QA device to improve the efficiency and thoroughness. Reasonable action level has been established by considering dosimetric relevance and clinic flow. As for intricate treatments, the effect of dose deviation caused by setup errors remains uncertain on tumor coverage and toxicity on OARs. The lack of adequate dosimetric simulations based on the true treatment coordinates from the treatment planning system (TPS) has limited adaptive treatments. A reliable and accurate dosimetric simulation using TPS and in-house software in uncorrected errors has been developed. In SRT, the calculated dose deviation is compared to the original treatment dose with the dose-volume histogram to investigate the dose effect of rotational errors. In summary, this work performed a quality assessment to investigate the overall accuracy of current setup systems. To reach the ideal HPRT, the reliable dosimetric simulation, an effective daily QA program and effective, precise setup systems were developed and validated.
Closed-Loop- and Decision-Assist-Guided Fluid Therapy of Human Hemorrhage.
Hundeshagen, Gabriel; Kramer, George C; Ribeiro Marques, Nicole; Salter, Michael G; Koutrouvelis, Aristides K; Li, Husong; Solanki, Daneshvari R; Indrikovs, Alexander; Seeton, Roger; Henkel, Sheryl N; Kinsky, Michael P
2017-10-01
We sought to evaluate the efficacy, efficiency, and physiologic consequences of automated, endpoint-directed resuscitation systems and compare them to formula-based bolus resuscitation. Experimental human hemorrhage and resuscitation. Clinical research laboratory. Healthy volunteers. Subjects (n = 7) were subjected to hemorrhage and underwent a randomized fluid resuscitation scheme on separate visits 1) formula-based bolus resuscitation; 2) semiautonomous (decision assist) fluid administration; and 3) fully autonomous (closed loop) resuscitation. Hemodynamic variables, volume shifts, fluid balance, and cardiac function were monitored during hemorrhage and resuscitation. Treatment modalities were compared based on resuscitation efficacy and efficiency. All approaches achieved target blood pressure by 60 minutes. Following hemorrhage, the total amount of infused fluid (bolus resuscitation: 30 mL/kg, decision assist: 5.6 ± 3 mL/kg, closed loop: 4.2 ± 2 mL/kg; p < 0.001), plasma volume, extravascular volume (bolus resuscitation: 17 ± 4 mL/kg, decision assist: 3 ± 1 mL/kg, closed loop: -0.3 ± 0.3 mL/kg; p < 0.001), body weight, and urinary output remained stable under decision assist and closed loop and were significantly increased under bolus resuscitation. Mean arterial pressure initially decreased further under bolus resuscitation (-10 mm Hg; p < 0.001) and was lower under bolus resuscitation than closed loop at 20 minutes (bolus resuscitation: 57 ± 2 mm Hg, closed loop: 69 ± 4 mm Hg; p = 0.036). Colloid osmotic pressure (bolus resuscitation: 19.3 ± 2 mm Hg, decision assist, closed loop: 24 ± 0.4 mm Hg; p < 0.05) and hemoglobin concentration were significantly decreased after bolus fluid administration. We define efficacy of decision-assist and closed-loop resuscitation in human hemorrhage. In comparison with formula-based bolus resuscitation, both semiautonomous and autonomous approaches were more efficient in goal-directed resuscitation of hemorrhage. They provide favorable conditions for the avoidance of over-resuscitation and its adverse clinical sequelae. Decision-assist and closed-loop resuscitation algorithms are promising technological solutions for constrained environments and areas of limited resources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diot, Q; Kavanagh, B; Miften, M
2014-06-15
Purpose: To propose a quantitative method using lung deformations to differentiate between radiation-induced fibrosis and potential airway stenosis with distal atelectasis in patients treated with stereotactic body radiation therapy (SBRT) for lung tumors. Methods: Twenty-four lung patients with large radiation-induced density increases outside the high dose region had their pre- and post-treatment CT scans manually registered. They received SBRT treatments at our institution between 2002 and 2009 in 3 or 5 fractions, to a median total dose of 54Gy (range, 30–60). At least 50 anatomical landmarks inside the lung (airway branches) were paired for the pre- and post-treatment scans tomore » guide the deformable registration of the lung structure, which was then interpolated to the whole lung using splines. Local volume changes between the planning and follow-up scans were calculated using the deformation field Jacobian. Hyperdense regions were classified as atelectatic or fibrotic based on correlations between regional density increases and significant volume contractions compared to the surrounding tissues. Results: Out of 24 patients, only 7 demonstrated a volume contraction that was at least one σ larger than the remaining lung average. Because they did not receive high doses, these shrunk hyperdense regions were likely showing distal atelectasis resulting from radiation-induced airway stenosis rather than conventional fibrosis. On average, the hyperdense regions extended 9.2 cm farther than the GTV contours but not significantly more than 8.6 cm for the other patients (p>0.05), indicating that a large offset between the radiation and hyperdense region centers is not a good surrogate for atelectasis. Conclusion: A method based on the relative comparison of volume changes between different dates was developed to identify potential lung regions experiencing distal atelectasis. Such a tool is essential to study which lung structures need to be avoided to prevent atelectasis and limit lung function loss.« less
Morimoto, Masahiro; Yoshioka, Yasuo; Shiomi, Hiroya; Isohashi, Fumiaki; Konishi, Koji; Kotsuma, Tadayuki; Fukuda, Shoichi; Kagawa, Naoki; Kinoshita, Manabu; Hashimoto, Naoya; Yoshimine, Toshiki; Koizumi, Masahiko
2011-05-01
To investigate the treatment results of intracranial meningiomas treated with hypofractionated stereotactic radiation therapy in three to five fractions. Thirty-one patients (32 lesions) with intracranial meningioma were treated with hypofractionated stereotactic radiation therapy in three to five fractions using CyberKnife. Fifteen lesions were diagnosed as Grade I (World Health Organization classification) by surgical resection and 17 lesions were diagnosed as meningioma based on radiological findings. The median follow-up time was 48 months. The median planning target volume was 6.3 cm(3) (range, 1.4-27.1), and the prescribed dose (D90≤) ranged from 21 to 36 Gy (median, 27.8) administrated in three to five fractions. Five-year overall and progression-free survival rate of all 31 patients with intracranial meningioma was 86 and 83%, respectively. Five-year progression-free rate of all 32 lesions was 87%. Six of the 31 patients (19%) developed marked peritumoral edema, three of whom were asymptomatic and three symptomatic, the latter with late adverse effects of more than or equal to Grade 3. The mean planning target volume of the six lesions with marked peritumoral edema was 15.6 cm(3), and for the remaining 26 lesions without marked peritumoral edema was 7.1 cm(3) (P = 0.004). The threshold diameter of 2.56 cm for meningioma was calculated from the planning target volume (11 cm(3)) and was used as marker of developing peritumoral edema (P = 0.003). Tumor volume is a significant indicative factor for peritumoral edema in intracranial meningioma treated with hypofractionated stereotactic radiation therapy in three to five factions.
Stereotactic radiosurgery for focal leptomeningeal disease in patients with brain metastases.
Wolf, Amparo; Donahue, Bernadine; Silverman, Joshua S; Chachoua, Abraham; Lee, Jean K; Kondziolka, Douglas
2017-08-01
Leptomeningeal disease (LMD) is well described in patients with brain metastases, presenting symptomatically in approximately 5% of patients. Conventionally, the presence of LMD is an indication for whole brain radiation therapy (WBRT) and not suitable for stereotactic radiosurgery (SRS). The purpose of the study was to evaluate the local control and overall survival of patients who underwent SRS to focal LMD. We reviewed our prospective registry and identified 32 brain metastases patients with LMD, from a total of 465 patients who underwent SRS between 2013 and 2015. Focal LMD was targeted with SRS in 16 patients. The median imaging follow-up time was 7 months. The median volume of LMD was 372 mm 3 and the median margin dose was 16 Gy. Five patients underwent prior WBRT. Histology included non-small cell lung (8), breast (5), melanoma (1), gastrointestinal (1) and ovarian cancer (1). Follow-up MR imaging was available for 14 patients. LMD was stable in 5 and partially regressed in 8 patients at follow-up. One patient had progression of LMD with hemorrhage 5 months after SRS. Seven patients developed distant LMD at a median time of 7 months. The median actuarial overall survival from SRS for LMD was 10.0 months. The 6-month and 1-year actuarial overall survival was 60% and 26% respectively. Six patients underwent WBRT after SRS for focal LMD at a median time of 6 months. Overall, focal LMD may be may be treated successfully with radiosurgery, potentially delaying WBRT in some patients.
Uncontrolled Hemorrhage Differs From Volume- or Pressure-Matched Controlled Hemorrhage in Swine
2007-10-01
differences between these models, we evaluated the relationship between blood volume loss and blood pressure in controlled versus uncontrolled hemorrhage...aortotomy; (2) group P, controlled hemorrhage matched to the blood pressure profile of group U; or (3) group V, controlled hemorrhage matched to the...hemorrhage and received no fluid resuscitation. Group U resulted in a blood loss of 17.6 T 0.7 mL kgj1 and a reduction in blood pressure to 28 T 3 mmHg at
Image-guided positioning and tracking.
Ruan, Dan; Kupelian, Patrick; Low, Daniel A
2011-01-01
Radiation therapy aims at maximizing tumor control while minimizing normal tissue complication. The introduction of stereotactic treatment explores the volume effect and achieves dose escalation to tumor target with small margins. The use of ablative irradiation dose and sharp dose gradients requires accurate tumor definition and alignment between patient and treatment geometry. Patient geometry variation during treatment may significantly compromise the conformality of delivered dose and must be managed properly. Setup error and interfraction/intrafraction motion are incorporated in the target definition process by expanding the clinical target volume to planning target volume, whereas the alignment between patient and treatment geometry is obtained with an adaptive control process, by taking immediate actions in response to closely monitored patient geometry. This article focuses on the monitoring and adaptive response aspect of the problem. The term "image" in "image guidance" will be used in a most general sense, to be inclusive of some important point-based monitoring systems that can be considered as degenerate cases of imaging. Image-guided motion adaptive control, as a comprehensive system, involves a hierarchy of decisions, each of which balances simplicity versus flexibility and accuracy versus robustness. Patient specifics and machine specifics at the treatment facility also need to be incorporated into the decision-making process. Identifying operation bottlenecks from a system perspective and making informed compromises are crucial in the proper selection of image-guidance modality, the motion management mechanism, and the respective operation modes. Not intended as an exhaustive exposition, this article focuses on discussing the major issues and development principles for image-guided motion management systems. We hope these information and methodologies will facilitate conscientious practitioners to adopt image-guided motion management systems accounting for patient and institute specifics and to embrace advances in knowledge and new technologies subsequent to the publication of this article.
Kim, Moinay; Cheok, Stephanie; Chung, Lawrance K.; Ung, Nolan; Thill, Kimberly; Voth, Brittany; Kwon, Do Hoon; Kim, Jeong Hoon; Kim, Chang Jin; Tenn, Stephen; Lee, Percy
2015-01-01
Brain metastasis represents one of the most common causes of intracranial tumors in adults, and the incidence of brain metastasis continues to rise due to the increasing survival of cancer patients. Yet, the development of cystic brain metastasis remains a relatively rare occurrence. In this review, we describe the characteristics of cystic brain metastasis and evaluate the combined use of stereotactic aspiration and radiosurgery in treating large cystic brain metastasis. The results of several studies show that stereotactic radiosurgery produces comparable local tumor control and survival rates as other surgery protocols. When the size of the tumor interferes with radiosurgery, stereotactic aspiration of the metastasis should be considered to reduce the target volume as well as decreasing the chance of radiation induced necrosis and providing symptomatic relief from mass effect. The combined use of stereotactic aspiration and radiosurgery has strong implications in improving patient outcomes. PMID:25977901
Kirkpatrick, John P; Wang, Zhiheng; Sampson, John H; McSherry, Frances; Herndon, James E; Allen, Karen J; Duffy, Eileen; Hoang, Jenny K; Chang, Zheng; Yoo, David S; Kelsey, Chris R; Yin, Fang-Fang
2015-01-01
To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board-approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diameters less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator-based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non-small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in neurocognition or quality of life was observed. SRS was well tolerated, with low rates of LR and RN in both cohorts. However, given the higher potential risk of RN with a 3-mm margin, a 1-mm GTV expansion is more appropriate. Copyright © 2015 Elsevier Inc. All rights reserved.
Cysouw, Matthijs; Bouman-Wammes, Esther; Hoekstra, Otto; van den Eertwegh, Alfons; Piet, Maartje; van Moorselaar, Jeroen; Boellaard, Ronald; Dahele, Max; Oprea-Lager, Daniela
2018-06-01
To investigate the predictive value of [ 18 F]-fluoromethylcholine positron emission tomography/computed tomography (PET/CT)-derived parameters on progression-free survival (PFS) in oligometastatic prostate cancer patients treated with stereotactic body radiation therapy (SBRT). In [ 18 F]-fluoromethylcholine PET/CT scans of 40 consecutive patients with ≤4 metachronous metastases treated with SBRT we retrospectively measured the number of metastases, standardized uptake values (SUV mean , SUV max , SUV peak ), metabolically active tumor volume (MATV), and total lesion choline uptake. Partial-volume correction was applied using the iterative deconvolution Lucy-Richardson algorithm. Thirty-seven lymph node and 13 bone metastases were treated with SBRT. Thirty-three patients (82.5%) had 1 lesion, 4 (10%) had 2 lesions, and 3 (7.5%) had 3 lesions. After a median follow-up of 32.6 months (interquartile range, 35.5 months), the median PFS was 11.5 months (95% confidence interval 8.4-14.6 months). Having more than a single metastasis was a significant prognostic factor (hazard ratio 2.74; P = .03), and there was a trend in risk of progression for large MATV (hazard ratio 1.86; P = .10). No SUV or total lesion choline uptake was significantly predictive for PFS, regardless of partial-volume correction. All PET semiquantitative parameters were significantly correlated with each other (P ≤ .013). The number of choline-avid metastases was a significant prognostic factor for progression after [ 18 F]-fluormethylcholine PET/CT-guided SBRT for recurrent oligometastatic prostate cancer, and there seemed to be a trend in risk of progression for patients with large MATVs. The lesional level of [ 18 F]-fluoromethylcholine uptake was not prognostic for progression. Copyright © 2018 Elsevier Inc. All rights reserved.
Ohtakara, Kazuhiro; Hoshi, Hiroaki
2014-12-01
This study sought to evaluate the potential geometrical change and/or displacement of the target relative to the cranium during fractionated stereotactic radiotherapy (FSRT) for treating newly developed brain metastases. For 16 patients with 21 lesions treated with image-guided frameless FSRT in 5 or 10 fractions using a 6-degree-of-freedom image guidance system-integrated platform, the unenhanced computed tomography or T2-weighted magnetic resonance images acquired until the completion of FSRT were fused to the planning image datasets for comparison. Significant change was defined as ≥3-mm change in the tumour diameter or displacement of the tumour centroid. FSRT was started 1 day after planning image acquisition. Tumour shrinkage, deviation and both were observed in 2, 1 and 1 of the 21 lesions, respectively, over a period of 7-13 days. Tumour shrinkage or deviation resulted in an increase or decrease in the marginal dose to the tumour, respectively, and a substantial increase in the irradiated volume for the surrounding tissue irrespective of the pattern of alteration. No obvious differences in the clinical and treatment characteristics were noted among the populations with or without significant changes in tumour volume or position. Target deformity and/or deviation can unexpectedly occur even during relatively short-course FSRT, inevitably leading to a gradual discrepancy between the planned and actually delivered doses to the tumour and surrounding tissue. To appropriately weigh the treatment outcome against the planned dose distribution, target deformity and/or deviation should also be considered in addition to the immobilisation accuracy, as image guidance with bony anatomy alignment does not necessarily guarantee accurate target localisation until completion of FSRT. © 2014 The Royal Australian and New Zealand College of Radiologists.
Is it sufficient to repeat LINEAR accelerator stereotactic radiosurgery in choroidal melanoma?
Furdova, A; Horkovicova, K; Justusova, P; Sramka, M
One day session LINAC based stereotactic radiosurgery (SRS) at LINAC accelerator is a method of "conservative" attitude to treat the intraocular malignant uveal melanoma. We used model Clinac 600 C/D Varian (system Aria, planning system Corvus version 6.2 verification IMRT OmniPro) with 6 MeV X by rigid immobilization of the eye to the Leibinger frame. The stereotactic treatment planning after fusion of CT and MRI was optimized according to the critical structures (lens, optic nerve, also lens and optic nerve at the contralateral side, chiasm). The first plan was compared and the best plan was applied for therapy at C LINAC accelerator. The planned therapeutic dose was 35.0 Gy by 99 % of DVH (dose volume histogram). In our clinical study in the group of 125 patients with posterior uveal melanoma treated with SRS, in 2 patients (1.6 %) was repeated SRS indicated. Patient age of the whole group ranged from 25 to 81 years with a median of 54 TD was 35.0 Gy. In 2 patients after 5 year interval after stereotactic radiosurgery for uveal melanoma stage T1, the tumor volume increased to 50 % of the primary tumor volume and repeated SRS was necessary. To find out the changes in melanoma characteristics after SRS in long term interval after irradiation is necessary to follow up the patient by an ophthalmologist regularly. One step LINAC based stereotactic radiosurgery with a single dose 35.0 Gy is one of treatment options to treat T1 to T3 stage posterior uveal melanoma and to preserve the eye globe. In some cases it is possible to repeat the SRS after more than 5 year interval (Fig. 8, Ref. 23).
Toward frameless stereotaxy: anatomical-vascular correlation and registration
NASA Astrophysics Data System (ADS)
Henri, Christopher J.; Cukiert, A.; Collins, D. Louis; Olivier, A.; Peters, Terence M.
1992-09-01
We present a method to correlate and register a projection angiogram with volume rendered tomographic data from the same patient. Previously, we have described how this may be accomplished using a stereotactic frame to handle the required coordinate transformations. Here we examine the efficacy of employing anatomically based landmarks as opposed to external fiducials to achieve the same results. The experiments required a neurosurgeon to identify several homologous points in a DSA image and a MRI volume which were subsequently used to compute the coordinate transformations governing the matching procedure. Correlation accuracy was assessed by comparing these results to those employing fiducial markers on a stereotactic frame, and by examining how different levels of noise in the positions of the homologous points affect the resulting coordinate transformations. Further simulations suggest that this method has potential to be used in planning stereotactic procedures without the use of a frame.
Stereotactic radiosurgery for trigeminal neuralgia utilizing the BrainLAB Novalis system.
Zahra, Hadi; Teh, Bin S; Paulino, Arnold C; Yoshor, Daniel; Trask, Todd; Baskin, David; Butler, E Brian
2009-12-01
Stereotactic radiosurgery (SRS) is one of the least invasive treatments for trigeminal neuralgia (TN). To date, most reports have been about Cobalt-based treatments (i.e., Gamma Knife) with limited data on image-guided stereotactic linear accelerator treatments. We describe our initial experience of using BrainLAB Novalis stereotactic system for the radiosurgical treatment of TN. A total of 20 patients were treated between July 2004 and February 2007. Each SRS procedure was performed using the BrainLAB Novalis System. Thin cuts MRI images of 1.5 mm thickness were acquired and fused with the simulation CT of each patient. Majority of the patients received a maximum dose of 90 Gy. The median brainstem dose to 1.0 cc and 0.1 cc was 2.3 Gy and 13.5 Gy, respectively. In addition, specially acquired three-dimensional fast imaging sequence employing steady-state acquisition (FIESTA) MRI was utilized to improve target delineation of the trigeminal proximal nerve root entry zone. Barrow Neurological Index (BNI) pain scale for TN was used for assessing treatment outcome. At a median follow-up time of 14.2 months, 19 patients (95%) reported at least some improvement in pain. Eight (40%) patients were completely pain-free and stopped all medications (BNI Grade I) while another 2 (10%) patients also stopped medications but reported occasional pain (BNI Grade II). Another 2 (10%) patients reported no pain and 7 (35%) patients only occasional pain while continuing medications, BNI Grade IIIA and IIIB, respectively. Median time to pain control was 8.5 days (range: 1-70 days). No patient reported severe pain, worsening pain or any pain not controlled on their previously taken medication. Intermittent or persistent facial numbness following treatments occurred in 35% of patients. No other complications were reported. Stereotactic radiosurgery using the BrainLAB Novalis system is a safe and effective treatment for TN. This information is important as more centers are obtaining image-guided stereotactic-based linear accelerators capable of performing radiosurgery.
Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.
2017-01-01
Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of greater help to detect hematoma formation, which is one of the most common complications of the biopsy procedure. PMID:29114280
Alongi, Filippo; Fiorentino, Alba; Mancosu, Pietro; Navarria, Pierina; Giaj Levra, Niccolò; Mazzola, Rosario; Scorsetti, Marta
2016-07-01
For intracranial metastases, the role of stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy is well recognized. Historically, the first technology, for stereotactic device able to irradiate a brain tumor volume, was Gamma Knife® (GK). Due to the technological advancement of linear accelerator (Linac), there was a continuous increasing interest in SRS Linac-based applications. In those decades, it was assumed a superiority of GK compared to SRS Linac-based for brain tumor in terms of dose conformity and rapid fall-off dose close to the target. Expert commentary: Recently, due to the Linac technologic advancement, the choice of SRS GK-based is not necessarily so exclusive. The current review discussed in details the technical and clinical aspects comparing the two approaches for brain metastases.
Flat epithelial atypia of the breast: pathological-radiological correlation.
Solorzano, Silma; Mesurolle, Benoît; Omeroglu, Attila; El Khoury, Mona; Kao, Ellen; Aldis, Ann; Meterissian, Sarkis
2011-09-01
This study was undertaken to determine the prevalence of flat epithelial atypia at ultrasound-guided and stereotactically guided needle biopsies, to describe the mammographic and sonographic features of flat epithelial atypia, and to determine the significance of lesions diagnosed as flat epithelial atypia at imaging-guided needle biopsies. Retrospective review of a database of 1369 consecutive sonographically and stereotactically guided needle biopsies performed during a 12-month period yielded 33 lesions with flat epithelial atypia as the most severe pathologic entity (32 patients). Two radiologists retrospectively reviewed the imaging presentation, by combined consensus, according to the BI-RADS lexicon. Twenty-two of 33 flat epithelial atypia diagnoses (67%) were obtained under stereotactic guidance, and 11 (33%) were obtained under sonographic guidance. Six patients had synchronous breast cancer. Flat epithelial atypia lesions presented mammographically most often as microcalcifications (20/33 [61%]) distributed in a cluster (14/20 [70%]) with amorphous morphology (13/20 [65%]). Sonographically, flat epithelial atypia lesions appeared most often as masses (9/11 [82%]), with an irregular shape (6/9 [67%]), microlobulated margins (5/9 [56%]), and hypoechoic or complex echotexture (7/9 [78%]). Twenty-eight of 33 lesions (85%) were surgically excised, confirming the flat epithelial atypia diagnosis in 11 of the 28 lesions (39%), yielding carcinoma in four (14%) and atypical ductal hyperplasia in six (21%). Columnar cell changes without atypia were diagnosed in four lesions (14%), and lobular carcinoma in situ was diagnosed in three lesions (11%). Mammographic and sonographic presentation of flat epithelial atypia is not specific (clustered amorphous microcalcifications and irregular, hypoechoic or complex masses). Given the underestimation rate of malignancy, surgical excision should be considered when imaging-guided biopsy yields flat epithelial atypia.
Robotic System for MRI-Guided Stereotactic Neurosurgery
Li, Gang; Cole, Gregory A.; Shang, Weijian; Harrington, Kevin; Camilo, Alex; Pilitsis, Julie G.; Fischer, Gregory S.
2015-01-01
Stereotaxy is a neurosurgical technique that can take several hours to reach a specific target, typically utilizing a mechanical frame and guided by preoperative imaging. An error in any one of the numerous steps or deviations of the target anatomy from the preoperative plan such as brain shift (up to 20 mm), may affect the targeting accuracy and thus the treatment effectiveness. Moreover, because the procedure is typically performed through a small burr hole opening in the skull that prevents tissue visualization, the intervention is basically “blind” for the operator with limited means of intraoperative confirmation that may result in reduced accuracy and safety. The presented system is intended to address the clinical needs for enhanced efficiency, accuracy, and safety of image-guided stereotactic neurosurgery for Deep Brain Stimulation (DBS) lead placement. The work describes a magnetic resonance imaging (MRI)-guided, robotically actuated stereotactic neural intervention system for deep brain stimulation procedure, which offers the potential of reducing procedure duration while improving targeting accuracy and enhancing safety. This is achieved through simultaneous robotic manipulation of the instrument and interactively updated in situ MRI guidance that enables visualization of the anatomy and interventional instrument. During simultaneous actuation and imaging, the system has demonstrated less than 15% signal-to-noise ratio (SNR) variation and less than 0.20% geometric distortion artifact without affecting the imaging usability to visualize and guide the procedure. Optical tracking and MRI phantom experiments streamline the clinical workflow of the prototype system, corroborating targeting accuracy with 3-axis root mean square error 1.38 ± 0.45 mm in tip position and 2.03 ± 0.58° in insertion angle. PMID:25376035
NASA Astrophysics Data System (ADS)
Tariq, Imran; Humbert-Vidan, Laia; Chen, Tao; South, Christopher P.; Ezhil, Veni; Kirkby, Norman F.; Jena, Rajesh; Nisbet, Andrew
2015-05-01
This paper reports a modelling study of tumour volume dynamics in response to stereotactic ablative radiotherapy (SABR). The main objective was to develop a model that is adequate to describe tumour volume change measured during SABR, and at the same time is not excessively complex as lacking support from clinical data. To this end, various modelling options were explored, and a rigorous statistical method, the Akaike information criterion, was used to help determine a trade-off between model accuracy and complexity. The models were calibrated to the data from 11 non-small cell lung cancer patients treated with SABR. The results showed that it is feasible to model the tumour volume dynamics during SABR, opening up the potential for using such models in a clinical environment in the future.
Time-dependent cell disintegration kinetics in lung tumors after irradiation
NASA Astrophysics Data System (ADS)
Chvetsov, Alexei V.; Palta, Jatinder J.; Nagata, Yasushi
2008-05-01
We study the time-dependent disintegration kinetics of tumor cells that did not survive radiotherapy treatment. To evaluate the cell disintegration rate after irradiation, we studied the volume changes of solitary lung tumors after stereotactic radiotherapy. The analysis is performed using two approximations: (1) tumor volume is a linear function of the total cell number in the tumor and (2) the cell disintegration rate is governed by the exponential decay with constant risk, which is defined by the initial cell number and a half-life T1/2. The half-life T1/2 is determined using the least-squares fit to the clinical data on lung tumor size variation with time after stereotactic radiotherapy. We show that the tumor volume variation after stereotactic radiotherapy of solitary lung tumors can be approximated by an exponential function. A small constant component in the volume variation does not change with time; however, this component may be the residual irregular density due to radiation fibrosis and was, therefore, subtracted from the total volume variation in our computations. Using computerized fitting of the exponent function to the clinical data for selected patients, we have determined that the average half-life T1/2 of cell disintegration is 28.2 days for squamous cell carcinoma and 72.4 days for adenocarcinoma. This model is needed for simulating the tumor volume variation during radiotherapy, which may be important for time-dependent treatment planning of proton therapy that is sensitive to density variations.
Feasibility of Adaptive MR-guided Stereotactic Body Radiotherapy (SBRT) of Lung Tumors
Simpson, Garrett N; Llorente, Ricardo; Samuels, Michael A; Dogan, Nesrin
2018-01-01
Online adaptive radiotherapy (ART) with frequent imaging has the potential to improve dosimetric accuracy by accounting for anatomical and functional changes during the course of radiotherapy. Presented are three interesting cases that provide an assessment of online adaptive magnetic resonance-guided radiotherapy (MRgRT) for lung stereotactic body radiotherapy (SBRT). The study includes three lung SBRT cases, treated on an MRgRT system where MR images were acquired for planning and prior to each treatment fraction. Prescription dose ranged from 48 to 50 Gy in four to five fractions, normalized to where 95% of the planning target volume (PTV) was covered by 100% of the prescription dose. The process begins with the gross tumor volume (GTV), PTV, spinal cord, lungs, heart, and esophagus being delineated on the planning MRI. The treatment plan was then generated using a step-and-shoot intensity modulated radiotherapy (IMRT) technique, which utilized a Monte Carlo dose calculation. Next, the target and organs at risk (OAR) contours from the planning MRI were deformably propagated to the daily setup MRIs. These deformed contours were reviewed and modified by the physician. To determine the efficacy of ART, two different strategies were explored: 1) Calculating the plan created for the planning MR on each fraction setup MR dataset (Non-Adapt) and 2) creating a new optimized IMRT plan on the fraction setup MR dataset (FxAdapt). The treatment plans from both strategies were compared using the clinical dose-volume constraints. PTV coverage constraints were not met for 33% Non-Adapt fractions; all FxAdapt fractions met this constraint. Eighty-eight percent of all OAR constraints studied were better on FxAdapt plans, while 12% of OAR constraints were superior on Non-Adapt fractions. The OAR that garnered the largest benefit would be the uninvolved lung, with superior sparing in 92% of the FxAdapt studied. Similar, but less pronounced, benefits from adaptive planning were experienced for the spinal cord, chest wall, and esophagus. Online adaptive MR-guided lung SBRT can provide better target conformality and homogeneity and OAR sparing compared with non-adaptive SBRT in selected cases. Conversely, if the PTV isn’t adjacent to multiple OARs, then the benefit from ART may be limited. Further studies, which incorporate a larger cohort of patients with uniform prescriptions, are needed to thoroughly evaluate the benefits of daily online ART during MRgRT. PMID:29872603
NASA Astrophysics Data System (ADS)
Bates, Lisa M.; Hanson, Dennis P.; Kall, Bruce A.; Meyer, Frederic B.; Robb, Richard A.
1998-06-01
An important clinical application of biomedical imaging and visualization techniques is provision of image guided neurosurgical planning and navigation techniques using interactive computer display systems in the operating room. Current systems provide interactive display of orthogonal images and 3D surface or volume renderings integrated with and guided by the location of a surgical probe. However, structures in the 'line-of-sight' path which lead to the surgical target cannot be directly visualized, presenting difficulty in obtaining full understanding of the 3D volumetric anatomic relationships necessary for effective neurosurgical navigation below the cortical surface. Complex vascular relationships and histologic boundaries like those found in artereovenous malformations (AVM's) also contribute to the difficulty in determining optimal approaches prior to actual surgical intervention. These difficulties demonstrate the need for interactive oblique imaging methods to provide 'line-of-sight' visualization. Capabilities for 'line-of- sight' interactive oblique sectioning are present in several current neurosurgical navigation systems. However, our implementation is novel, in that it utilizes a completely independent software toolkit, AVW (A Visualization Workshop) developed at the Mayo Biomedical Imaging Resource, integrated with a current neurosurgical navigation system, the COMPASS stereotactic system at Mayo Foundation. The toolkit is a comprehensive, C-callable imaging toolkit containing over 500 optimized imaging functions and structures. The powerful functionality and versatility of the AVW imaging toolkit provided facile integration and implementation of desired interactive oblique sectioning using a finite set of functions. The implementation of the AVW-based code resulted in higher-level functions for complete 'line-of-sight' visualization.
Huang, Yuexi; Alkins, Ryan; Schwartz, Michael L; Hynynen, Kullervo
2017-01-01
Purpose To develop and test a protocol in preparation for a clinical trial on opening the blood-brain barrier (BBB) with magnetic resonance (MR) imaging-guided focused ultrasound for the delivery of chemotherapy drugs to brain tumors. Materials and Methods The procedures were approved by the institutional animal care committee. A trans-human skull porcine model was designed for the preclinical testing. Wide craniotomies were applied in 11 pigs (weight, approximately 15 kg). A partial human skull was positioned over the animal's brain. A modified clinical MR imaging-guided focused ultrasound brain system was used with a 3.0-T MR unit. The ultrasound beam was steered during sonications over a 3 × 3 grid at 3-mm spacing. Acoustic power levels of 3-20 W were tested. Bolus injections of microbubbles at 4 μL/kg were tested for each sonication. Levels of BBB opening, hemorrhage, and cavitation signal were measured with MR imaging, histologic examination, and cavitation receivers, respectively. A cavitation safety algorithm was developed on the basis of logistic regression of the measurements and tested to minimize the risk of hemorrhage. Results BBB openings of approximately 1 cm 3 in volume were visualized with gadolinium-enhanced MR imaging after sonication at an acoustic power of approximately 5 W. Gross examination of histologic specimens helped confirm Evans blue (bound to macromolecule albumin) extravasation, and hematoxylin-eosin staining helped detect only scattered extravasation of red blood cells. In cases where cavitation signals were higher than thresholds, sonications were terminated immediately without causing hemorrhage. Conclusion With a trans-human skull porcine model, this study demonstrated BBB opening with a 230-kHz system in preparation for a clinical trial. © RSNA, 2016 Online supplemental material is available for this article.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kung, Shiris Wai Sum; Wu, Vincent Wing Cheung; Kam, Michael Koon Ming, E-mail: kamkm@yahoo.co
2011-01-01
Purpose: Locally recurrent nasopharyngeal carcinoma (NPC) patients can be salvaged by reirradiation with a substantial degree of radiation-related complications. Stereotactic radiotherapy (SRT) is widely used in this regard because of its rapid dose falloff and high geometric precision. The aim of this study was to examine whether the newly developed intensity-modulated stereotactic radiotherapy (IMSRT) has any dosimetric advantages over three other stereotactic techniques, including circular arc (CARC), static conformal beam (SmMLC), and dynamic conformal arc (mARC), in treating locally recurrent NPC. Methods and Materials: Computed tomography images of 32 patients with locally recurrent NPC, previously treated with SRT, were retrievedmore » from the stereotactic planning system for contouring and computing treatment plans. Treatment planning of each patient was performed for the four treatment techniques: CARC, SmMLC, mARC, and IMSRT. The conformity index (CI) and homogeneity index (HI) of the planning target volume (PTV) and doses to the organs at risk (OARs) and normal tissue were compared. Results: All four techniques delivered adequate doses to the PTV. IMSRT, SmMLC, and mARC delivered reasonably conformal and homogenous dose to the PTV (CI <1.47, HI <0.53), but not for CARC (p < 0.05). IMSRT presented with the smallest CI (1.37) and HI (0.40). Among the four techniques, IMSRT spared the greatest number of OARs, namely brainstem, temporal lobes, optic chiasm, and optic nerve, and had the smallest normal tissue volume in the low-dose region. Conclusion: Based on the dosimetric comparison, IMSRT was optimal for locally recurrent NPC by delivering a conformal and homogenous dose to the PTV while sparing OARs.« less
Iridium-Knife: Another knife in radiation oncology.
Milickovic, Natasa; Tselis, Nikolaos; Karagiannis, Efstratios; Ferentinos, Konstantinos; Zamboglou, Nikolaos
Intratarget dose escalation with superior conformity is a defining feature of three-dimensional (3D) iridium-192 ( 192 Ir) high-dose-rate (HDR) brachytherapy (BRT). In this study, we analyzed the dosimetric characteristics of interstitial 192 Ir HDR BRT for intrathoracic and cerebral malignancies. We examined the dose gradient sharpness of HDR BRT compared with that of linear accelerator-based stereotactic radiosurgery and stereotactic body radiation therapy, usually called X-Knife, to demonstrate that it may as well be called a Knife. Treatment plans for 10 patients with recurrent glioblastoma multiforme or intrathoracic malignancies, five of each entity, treated with X-Knife (stereotactic radiosurgery for glioblastoma multiforme and stereotactic body radiation therapy for intrathoracic malignancies) were replanned for simulated HDR BRT. For 3D BRT planning, we used identical structure sets and dose prescription as for the X-Knife planning. The indices for qualitative treatment plan analysis encompassed planning target volume coverage, conformity, dose falloff gradient, and the maximum dose-volume limits to different organs at risk. Volume coverage in HDR plans was comparable to that calculated for X-Knife plans with no statistically significant difference in terms of conformity. The dose falloff gradient-sharpness-of the HDR plans was considerably steeper compared with the X-Knife plans. Both 3D 192 Ir HDR BRT and X-Knife are effective means for intratarget dose escalation with HDR BRT achieving at least equal conformity and a steeper dose falloff at the target volume margin. In this sense, it can reasonably be argued that 3D 192 Ir HDR BRT deserves also to be called a Knife, namely Iridium-Knife. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Protons and more: state of the art in radiotherapy.
Hoskin, Peter J; Bhattacharya, Indrani S
2014-12-01
The purpose of modern radiotherapy is to deliver a precise high dose of radiation which will result in reproductive death of the cells. Radiation should transverse within the tumour volume whilst minimising damage to surrounding normal tissue. Overall 40% of cancers which are cured will have received radiotherapy. Current state of the art treatment will incorporate cross-sectional imaging and multiple high energy X-ray beams in processes called intensity modulated radiotherapy and image guided radiotherapy. Brachytherapy enables very high radiation doses to be delivered by the direct passage of a radiation source through or within the tumour volume and similar results can be achieved using rotational stereotactic X-ray beam techniques. Protons have the characteristics of particle beams which deposit their energy in a finite fixed peak at depth in tissue with no dose beyond this point - the Bragg peak. This has advantages in certain sites such as the spine adjacent to the spinal cord and particularly in children when the overall volume of tissue receiving radiation can be minimised. © 2014 Royal College of Physicians.
2015-10-01
malignant PNs treated with stereotactic ablative radiotherapy ( SABR ) with those of the lung. Methods: We analyzed breath-hold images of 30...patients with malignant PNs who underwent SABR in our department. A parametric nonrigid transformation model based on multi-level B-spline guided by Sum of...and 50 of 4D CT and deep inhale and natural exhale of breath-hold CT images of 30 MPN treated with stereotactic ablative radiotherapy ( SABR ). The
Pressor and hemodilution responses compensate for acute hemorrhage in bluefish.
Ogilvy, C S; Tremml, P G; DuBois, A B
1988-01-01
1. After hemorrhage of 21% blood volume (0.9% body weight) blood pressure (BP) and heart rate (H.R.) of unanesthetized bluefish (Pomatomus saltatrix) recovered within 5 min. 2. Phentolamine blocked this recovery. 3. Atropine increased control H.R. from 48 to 87 per min, and to 108 after hemorrhage, with delay of BP recovery to 10 min. 4. With small, repeated hemorrhages every 20 min, hemodilution and recovery of BP occurred between hemorrhages. Removal of 27% blood volume resulted in only temporary recovery. 5. Thirty min after hemorrhage, plasma epinephrine was 5 x and norepinephrine 8 x control. 6. Thus, bluefish tolerate hemorrhage with initial vasoconstriction via alpha-adrenergic pathways, and hemodilution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, N., E-mail: nwen1@hfhs.org; Snyder, K. C.; Qin, Y.
2016-05-15
Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2more » mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.« less
Lagares, Alfonso; Jiménez-Roldán, Luis; Gomez, Pedro A; Munarriz, Pablo M; Castaño-León, Ana M; Cepeda, Santiago; Alén, José F
2015-12-01
Quantitative estimation of the hemorrhage volume associated with aneurysm rupture is a new tool of assessing prognosis. To determine the prognostic value of the quantitative estimation of the amount of bleeding after aneurysmal subarachnoid hemorrhage, as well the relative importance of this factor related to other prognostic indicators, and to establish a possible cut-off value of volume of bleeding related to poor outcome. A prospective cohort of 206 patients consecutively admitted with the diagnosis of aneurysmal subarachnoid hemorrhage to Hospital 12 de Octubre were included in the study. Subarachnoid, intraventricular, intracerebral, and total bleeding volumes were calculated using analytic software. For assessing factors related to prognosis, univariate and multivariate analysis (logistic regression) were performed. The relative importance of factors in determining prognosis was established by calculating their proportion of explained variation. Maximum Youden index was calculated to determine the optimal cut point for subarachnoid and total bleeding volume. Variables independently related to prognosis were clinical grade at admission, age, and the different bleeding volumes. The proportion of variance explained is higher for subarachnoid bleeding. The optimal cut point related to poor prognosis is a volume of 20 mL both for subarachnoid and total bleeding. Volumetric measurement of subarachnoid or total bleeding volume are both independent prognostic factors in patients with aneurysmal subarachnoid hemorrhage. A volume of more than 20 mL of blood in the initial noncontrast computed tomography is related to a clear increase in poor outcome risk. : aSAH, aneurysmal subarachnoid hemorrhage.
A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.
Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I
2017-09-01
To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Wang, Shu-wen; Ren, Juan; Yan, Yan-li; Xue, Chao-fan; Tan, Li; Ma, Xiao-wei
2016-01-01
The objective of this study was to compare the effects of image-guided hypofractionated radiotherapy and conventional fractionated radiotherapy on non-small-cell lung cancer (NSCLC). Fifty stage- and age-matched cases with NSCLC were randomly divided into two groups (A and B). There were 23 cases in group A and 27 cases in group B. Image-guided radiotherapy (IGRT) and stereotactic radiotherapy were conjugately applied to the patients in group A. Group A patients underwent hypofractionated radiotherapy (6–8 Gy/time) three times per week, with a total dose of 64–66 Gy; group B received conventional fractionated radiotherapy, with a total dose of 68–70 Gy five times per week. In group A, 1-year and 2-year local failure survival rate and 1-year local failure-free survival rate were significantly higher than in group B (P<0.05). The local failure rate (P<0.05) and distant metastasis rate (P>0.05) were lower in group A than in group B. The overall survival rate of group A was significantly higher than that of group B (P=0.03), and the survival rate at 1 year was 87% vs 63%, (P<0.05). The median survival time of group A was longer than that of group B. There was no significant difference in the incidence of complications between the two groups (P>0.05). Compared with conventional fractionated radiation therapy, image-guided hypofractionated stereotactic radiotherapy in NSCLC received better treatment efficacy and showed good tolerability. PMID:27574441
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calvo Ortega, Juan Francisco, E-mail: jfcdrr@yahoo.es; Wunderink, Wouter; Delgado, David
The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square fieldmore » and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacFadden, Derek; Zhang Beibei; Brock, Kristy K.
Purpose: Increasing the magnetic resonance imaging (MRI) field strength can improve image resolution and quality, but concerns remain regarding the influence on geometric fidelity. The objectives of the present study were to spatially investigate the effect of 3-Tesla (3T) MRI on clinical target localization for stereotactic radiosurgery. Methods and Materials: A total of 39 patients were enrolled in a research ethics board-approved prospective clinical trial. Imaging (1.5T and 3T MRI and computed tomography) was performed after stereotactic frame placement. Stereotactic target localization at 1.5T vs. 3T was retrospectively analyzed in a representative cohort of patients with tumor (n = 4)more » and functional (n = 5) radiosurgical targets. The spatial congruency of the tumor gross target volumes was determined by the mean discrepancy between the average gross target volume surfaces at 1.5T and 3T. Reproducibility was assessed by the displacement from an averaged surface and volume congruency. Spatial congruency and the reproducibility of functional radiosurgical targets was determined by comparing the mean and standard deviation of the isocenter coordinates. Results: Overall, the mean absolute discrepancy across all patients was 0.67 mm (95% confidence interval, 0.51-0.83), significantly <1 mm (p < .010). No differences were found in the overall interuser target volume congruence (mean, 84% for 1.5T vs. 84% for 3T, p > .4), and the gross target volume surface mean displacements were similar within and between users. The overall average isocenter coordinate discrepancy for the functional targets at 1.5T and 3T was 0.33 mm (95% confidence interval, 0.20-0.48), with no patient-specific differences between the mean values (p >.2) or standard deviations (p >.1). Conclusion: Our results have provided clinically relevant evidence supporting the spatial validity of 3T MRI for use in stereotactic radiosurgery under the imaging conditions used.« less
Neumann, Jan-Oliver; Giese, Henrik; Biller, Armin; Nagel, Armin M; Kiening, Karl
2015-01-01
Magnetic resonance imaging (MRI) is replacing computed tomography (CT) as the main imaging modality for stereotactic transformations. MRI is prone to spatial distortion artifacts, which can lead to inaccuracy in stereotactic procedures. Modern MRI systems provide distortion correction algorithms that may ameliorate this problem. This study investigates the different options of distortion correction using standard 1.5-, 3- and 7-tesla MRI scanners. A phantom was mounted on a stereotactic frame. One CT scan and three MRI scans were performed. At all three field strengths, two 3-dimensional sequences, volumetric interpolated breath-hold examination (VIBE) and magnetization-prepared rapid acquisition with gradient echo, were acquired, and automatic distortion correction was performed. Global stereotactic transformation of all 13 datasets was performed and two stereotactic planning workflows (MRI only vs. CT/MR image fusion) were subsequently analysed. Distortion correction on the 1.5- and 3-tesla scanners caused a considerable reduction in positional error. The effect was more pronounced when using the VIBE sequences. By using co-registration (CT/MR image fusion), even a lower positional error could be obtained. In ultra-high-field (7 T) MR imaging, distortion correction introduced even higher errors. However, the accuracy of non-corrected 7-tesla sequences was comparable to CT/MR image fusion 3-tesla imaging. MRI distortion correction algorithms can reduce positional errors by up to 60%. For stereotactic applications of utmost precision, we recommend a co-registration to an additional CT dataset. © 2015 S. Karger AG, Basel.
Gamboa, Nicholas T; Joyce, Evan J; Eli, Ilyas; Park, Min S; Taussky, Philipp; Schmidt, Richard H; McDonald, Jamie; Whitehead, Kevin J; Kalani, M Yashar S
2018-05-01
Hereditary hemorrhagic telangiectasia (HHT) is characterized by recurrent spontaneous epistaxis, mucocutaneous telangiectases, and multisystem arteriovenous malformations (AVMs). Brain AVMs typically present at birth and are identified in approximately 10-20% of patients with HHT. A retrospective review was undertaken of all HHT patients with known single or multiple brain AVMs treated at our institution. Thirty-nine patients with brain AVM(s) were diagnosed with HHT. Most patients presented with at least one Curaçao criterion. A total of 78 brain AVMs were identified in 39 patients. Two-thirds of patients had solitary brain AVMs, whereas 33% of patients harbored at least two lesions (range: 2-16). Brain AVMs of the supratentorial cerebral hemispheres comprised 83% of all lesions, whereas infratentorial lesions accounted for only 17%. Of the 55 brain AVMs assigned Spetzler-Martin grading, the majority of patients were Grade 1 (73%), and 23% and 4% were Grades 2 and 3, respectively. Patients were treated with surgery alone (51%), embolization alone (6%), embolization followed by surgery (9%), stereotactic radiosurgery (11%), stereotactic radiosurgery followed by surgery (3%), or observation (20%). Of patients who underwent genetic analysis, 62% possessed mutations in ENG (HHT type 1), whereas 38% had mutations in ACVRL1 (HHT type 2). This robust patient cohort of brain AVMs in 39 patients with HHT advances the collective understanding of this disease's varied presentation, diagnostic workup, genetic underpinnings, and available treatment options. Copyright © 2018. Published by Elsevier Ltd.
Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety.
Bekelis, Kimon; Radwan, Tarek A; Desai, Atman; Roberts, David W
2012-05-01
Frameless stereotactic brain biopsy has become an established procedure in many neurosurgical centers worldwide. Robotic modifications of image-guided frameless stereotaxy hold promise for making these procedures safer, more effective, and more efficient. The authors hypothesized that robotic brain biopsy is a safe, accurate procedure, with a high diagnostic yield and a safety profile comparable to other stereotactic biopsy methods. This retrospective study included 41 patients undergoing frameless stereotactic brain biopsy of lesions (mean size 2.9 cm) for diagnostic purposes. All patients underwent image-guided, robotic biopsy in which the SurgiScope system was used in conjunction with scalp fiducial markers and a preoperatively selected target and trajectory. Forty-five procedures, with 50 supratentorial targets selected, were performed. The mean operative time was 44.6 minutes for the robotic biopsy procedures. This decreased over the second half of the study by 37%, from 54.7 to 34.5 minutes (p < 0.025). The diagnostic yield was 97.8% per procedure, with a second procedure being diagnostic in the single nondiagnostic case. Complications included one transient worsening of a preexisting deficit (2%) and another deficit that was permanent (2%). There were no infections. Robotic biopsy involving a preselected target and trajectory is safe, accurate, efficient, and comparable to other procedures employing either frame-based stereotaxy or frameless, nonrobotic stereotaxy. It permits biopsy in all patients, including those with small target lesions. Robotic biopsy planning facilitates careful preoperative study and optimization of needle trajectory to avoid sulcal vessels, bridging veins, and ventricular penetration.
Lamas, Verónica; Estévez, Sheila; Pernía, Marianni; Plaza, Ignacio; Merchán, Miguel A
2017-10-11
The rat auditory cortex (AC) is becoming popular among auditory neuroscience investigators who are interested in experience-dependence plasticity, auditory perceptual processes, and cortical control of sound processing in the subcortical auditory nuclei. To address new challenges, a procedure to accurately locate and surgically expose the auditory cortex would expedite this research effort. Stereotactic neurosurgery is routinely used in pre-clinical research in animal models to engraft a needle or electrode at a pre-defined location within the auditory cortex. In the following protocol, we use stereotactic methods in a novel way. We identify four coordinate points over the surface of the temporal bone of the rat to define a window that, once opened, accurately exposes both the primary (A1) and secondary (Dorsal and Ventral) cortices of the AC. Using this method, we then perform a surgical ablation of the AC. After such a manipulation is performed, it is necessary to assess the localization, size, and extension of the lesions made in the cortex. Thus, we also describe a method to easily locate the AC ablation postmortem using a coordinate map constructed by transferring the cytoarchitectural limits of the AC to the surface of the brain.The combination of the stereotactically-guided location and ablation of the AC with the localization of the injured area in a coordinate map postmortem facilitates the validation of information obtained from the animal, and leads to a better analysis and comprehension of the data.
Aviv, R I; Huynh, T; Huang, Y; Ramsay, D; Van Slyke, P; Dumont, D; Asmah, P; Alkins, R; Liu, R; Hynynen, K
2014-09-01
The "spot sign" or contrast extravasation is strongly associated with hematoma formation and growth. An animal model of contrast extravasation is important to test existing and novel therapeutic interventions to inform present and future clinical studies. The purpose of this study was to create an animal model of contrast extravasation in acute intracerebral hemorrhage. Twenty-eight hemispheres of Yorkshire male swine were insonated with an MR imaging-guided focused sonography system following lipid microsphere infusion and mean arterial pressure elevation. The rate of contrast leakage was quantified by using dynamic contrast-enhanced MR imaging and was classified as contrast extravasation or postcontrast leakage by using postcontrast T1. Hematoma volume was measured on gradient recalled-echo MR imaging performed 2 hours postprocedure. Following this procedure, sacrificed brain was subjected to histopathologic examination. Power level, burst length, and blood pressure elevation were correlated with leakage rate, hematoma size, and vessel abnormality extent. Median (intracerebral hemorrhage) contrast extravasation leakage was higher than postcontrast leakage (11.3; 6.3-23.2 versus 2.4; 1.1-3.1 mL/min/100 g; P<.001). Increasing burst length, gradient recalled-echo hematoma (ρ=0.54; 95% CI, 0.2-0.8; P=.007), and permeability were correlated (ρ=0.55; 95% CI, 0.1-0.8; P=.02). Median permeability (P=.02), gradient recalled-echo hematoma (P=.02), and dynamic contrast-enhanced volumes (P=.02) were greater at 1000 ms than at 10 ms. Within each burst-length subgroup, incremental contrast leakage was seen with mean arterial pressure elevation (ρ=0.2-0.8). We describe a novel MR imaging-integrated real-time swine intracerebral hemorrhage model of acute hematoma growth and contrast extravasation. © 2014 by American Journal of Neuroradiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binkley, Michael S.; Shrager, Joseph B.; Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California
2014-09-01
Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABRmore » and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across multiple clinical parameters. These data serve to inform our ongoing prospective trial of stereotactic ablative volume reduction (SAVR) for severe emphysema in poor candidates for LVRS.« less
Pelvic re-irradiation using stereotactic ablative radiotherapy (SABR): A systematic review.
Murray, Louise Janet; Lilley, John; Hawkins, Maria A; Henry, Ann M; Dickinson, Peter; Sebag-Montefiore, David
2017-11-01
To perform a systematic review regarding the use of stereotactic ablative radiotherapy (SABR) for the re-irradiation of recurrent malignant disease within the pelvis, to guide the clinical implementation of this technique. A systematic search strategy was adopted using the MEDLINE, EMBASE and Cochrane Library databases. 195 articles were identified, of which 17 were appropriate for inclusion. Studies were small and data largely retrospective. In total, 205 patients are reported to have received pelvic SABR re-irradiation. Dose and fractionation schedules and re-irradiated volumes are highly variable. Little information is provided regarding organ at risk constraints adopted in the re-irradiation setting. Treatment appears well-tolerated overall, with nine grade 3 and six grade 4 toxicities amongst thirteen re-irradiated patients. Local control at one year ranged from 51% to 100%. Symptomatic improvements were also noted. For previously irradiated patients with recurrent pelvic disease, SABR re-irradiation could be a feasible intervention for those who otherwise have limited options. Evidence to support this technique is limited but shows initial promise. Based on the available literature, suggestions for a more formal SABR re-irradiation pathway are proposed. Prospective studies and a multidisciplinary approach are required to optimise future treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Kawase, Takatsugu; Kunieda, Etsuo; Deloar, Hossain M; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi
2009-10-01
To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.
Image-guided surgery in resection of benign cervicothoracic spinal tumors: a report of two cases.
Moore, Timothy; McLain, Robert F
2005-01-01
Osseous spinal tumors are an uncommon cause of persistent axial pain and muscle spasm, but even benign lesions may grow to cause deformity or neurological signs. Traditional treatment approaches to resection can be debilitating even when the tumor is benign. Emerging technologies allow surgeons to diagnose and treat osseous neoplasms while minimizing the collateral damage caused by surgical exposure and tumor excision. Technical considerations are presented through two cases of benign osseous neoplasm occurring in the cervicothoracic spine of competitive athletes, demonstrating the meth-ods used to provide effective treatment while maintaining maximal functional capacity. Stereotactic imaging and intraoperative guidance was used as an adjunct to tumor care in these patients. Used in combination with minimally invasive, microsurgical techniques,stereotactic guidance localized and verified excision margins of benign vertebral lesions, minimizing soft tissue trauma and collateral damage. Computer-assisted stereotactic localization allowed us to successfully ablate these lesions from their anatomically challenging locations, without disrupting the shoulder girdle or neck musculature, and without extensive bony resection. Image guidance can accurately localize and guide excision of benign vertebral lesions while minimizing soft tissue trauma and collateral damage, allowing patients a rapid and complete return to high-demand function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruschin, Mark, E-mail: Mark.Ruschin@rmp.uhn.on.c; Department of Radiation Oncology, University of Toronto, Toronto; Nayebi, Nazanin
2010-09-01
Purpose: To evaluate the geometric positioning and immobilization performance of a vacuum bite-block repositioning head frame (RHF) system for Perfexion (PFX-SRT) and linac-based intracranial image-guided stereotactic radiotherapy (SRT). Methods and Materials: Patients with intracranial tumors received linac-based image-guided SRT using the RHF for setup and immobilization. Three hundred thirty-three fractions of radiation were delivered in 12 patients. The accuracy of the RHF was estimated for linac-based SRT with online cone-beam CT (CBCT) and for PFX-SRT with a repositioning check tool (RCT) and offline CBCT. The RCT's ability to act as a surrogate for anatomic position was estimated through comparison tomore » CBCT image matching. Immobilization performance was evaluated daily with pre- and postdose delivery CBCT scans and RCT measurements. Results: The correlation coefficient between RCT- and CBCT-reported displacements was 0.59, 0.75, 0.79 (Right, Superior, and Anterior, respectively). For image-guided linac-based SRT, the mean three-dimensional (3D) setup error was 0.8 mm with interpatient ({Sigma}) and interfraction ({sigma}) variations of 0.1 and 0.4 mm, respectively. For PFX-SRT, the initial, uncorrected mean 3D positioning displacement in stereotactic coordinates was 2.0 mm, with {Sigma} = 1.1 mm and {sigma} = 0.8 mm. Considering only RCT setups <1mm (PFX action level) the mean 3D positioning displacement reduced to 1.3 mm, with {Sigma} = 0.9 mm and {sigma} = 0.4 mm. The largest contributing systematic uncertainty was in the superior-inferior direction (mean displacement = -0.5 mm; {Sigma} = 0.9 mm). The largest mean rotation was 0.6{sup o} in pitch. The mean 3D intrafraction motion was 0.4 {+-} 0.3 mm. Conclusion: The RHF provides excellent immobilization for intracranial SRT and PFX-SRT. Some small systematic uncertainties in stereotactic positioning exist and must be considered when generating PFX-SRT treatment plans. The RCT provides reasonable surrogacy for internal anatomic displacement.« less
Radiosurgery for Arteriovenous Malformations and the Impact on Headaches.
Bowden, Greg; Cavaleri, Jonathon; Kano, Hideyuki; Monaco, Edward; Niranjan, Ajay; Flickinger, John; Dade Lunsford, L
2017-05-01
Arteriovenous malformations (AVMs) can underlie many diverse neurological signs and symptoms. Headaches are a common presentation that can have a significant impact on quality of life. The authors investigated Gamma Knife ® stereotactic radiosurgery (SRS) outcomes in patients with AVMs and associated headaches. This retrospective study analyzed 102 patients with AVMs who underwent SRS between 1995 and 2013. The patient's headache symptoms led to their AVM diagnosis or developed post hemorrhage of their AVM. Information regarding headache characteristics was obtained from the patient's medical records and at follow-up using a scripted clinical interview. The median imaging follow-up was 61.7 months and clinical follow-up was 89.7 months. The median treatment volume at SRS was 4.1 cm 3 and the median marginal dose was 20 Gy. The actuarial AVM obliteration rate was 60% at 5 years and 78% at 10 years. Patients reported that their overall headache severity decreased by -43.6% and their headache frequency was reduced by -53.4%. Headache reduction was reported in 49.1% of patients at 1 year and 69.5% at 5 years. The median time until improvement was 6.5 months. After SRS, headache medication usage decreased in 29% of patients. Permanent adverse radiation effects after SRS occurred in 3% of patients. Until obliteration was complete, the annual risk of a hemorrhage after SRS was 0.4% per year. Although recall bias related to a retrospective analysis can impact outcomes, headache symptoms associated with AVMs may potentially be decreased or eliminated in a subset of patients treated with Gamma Knife radiosurgery. © 2017 American Headache Society.
Stereotactic interstitial radiosurgery for cerebral metastases.
Curry, William T; Cosgrove, Garth Rees; Hochberg, Fred H; Loeffler, Jay; Zervas, Nicholas T
2005-10-01
The Photon Radiosurgery System (PRS) is a miniature x-ray generator that can stereotactically irradiate intracranial tumors by using low-energy photons. Treatment with the PRS typically occurs in conjunction with stereotactic biopsy, thereby providing diagnosis and treatment in one procedure. The authors review the treatment of patients with brain metastases with the aid of the PRS and discuss the indications, advantages, and limitations of this technique. Clinical characteristics, treatment parameters, neuroimaging-confirmed outcome, and survival were reviewed in all patients with histologically verified brain metastases who were treated with the PRS at the Massachusetts General Hospital between December 1992 and November 2000. Local control of lesions was defined as either stabilization or diminution in the size of the treated tumor as confirmed by Gd-enhanced magnetic resonance imaging. Between December 1992 and November 2000, 72 intracranial metastatic lesions in 60 patients were treated with the PRS. Primary tumors included lung (33 patients), melanoma (15 patients), renal cell (five patients), breast (two patients), esophageal (two patients), colon (one patient), and Merkle cell (one patient) cancers, and malignant fibrous histiocytoma (one patient). Supratentorial metastases were distributed throughout the cerebrum, with only one cerebellar metastasis. The lesions ranged in diameter from 6 to 40 mm and were treated with a minimal peripheral dose of 16 Gy (range 10-20 Gy). At the last follow-up examination (median 6 months), local disease control had been achieved in 48 (81%) of 59 tumors. An actuarial analysis demonstrated that the survival rates at 6 and 12 months were 63 and 34%, respectively. Patients with a single brain metastasis survived a mean of 11 months. Complications included four patients with postoperative seizures, three with symptomatic cerebral edema, two with hemorrhagic events, and three with symptomatic radiation necrosis requiring surgery. Stereotactic interstitial radiosurgery performed using the PRS can obtain local control of cerebral metastases at rates that are comparable to those achieved through open resection and external stereotactic radiosurgery. The major advantage of using the PRS is that effective treatment can be accomplished at the time of stereotactic biopsy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hepel, Jaroslaw T., E-mail: jhepel@lifespan.org; Department of Radiation Oncology, Tufts Medical Center, Tufts University, Boston, Massachusetts; Leonard, Kara Lynne
Purpose: Stereotactic body radiation therapy (SBRT) boost to primary and nodal disease after chemoradiation has potential to improve outcomes for advanced non-small cell lung cancer (NSCLC). A dose escalation study was initiated to evaluate the maximum tolerated dose (MTD). Methods and Materials: Eligible patients received chemoradiation to a dose of 50.4 Gy in 28 fractions and had primary and nodal volumes appropriate for SBRT boost (<120 cc and <60 cc, respectively). SBRT was delivered in 2 fractions after chemoradiation. Dose was escalated from 16 to 28 Gy in 2 Gy/fraction increments, resulting in 4 dose cohorts. MTD was defined when ≥2 of 6 patients permore » cohort experienced any treatment-related grade 3 to 5 toxicity within 4 weeks of treatment or the maximum dose was reached. Late toxicity, disease control, and survival were also evaluated. Results: Twelve patients (3 per dose level) underwent treatment. All treatment plans met predetermined dose-volume constraints. The mean age was 64 years. Most patients had stage III disease (92%) and were medically inoperable (92%). The maximum dose level was reached with no grade 3 to 5 acute toxicities. At a median follow-up time of 16 months, 1-year local-regional control (LRC) was 78%. LRC was 50% at <24 Gy and 100% at ≥24 Gy (P=.02). Overall survival at 1 year was 67%. Late toxicity (grade 3-5) was seen in only 1 patient who experienced fatal bronchopulmonary hemorrhage (grade 5). There were no predetermined dose constraints for the proximal bronchial-vascular tree (PBV) in this study. This patient's 4-cc PBV dose was substantially higher than that received by other patients in all 4 cohorts and was associated with the toxicity observed: 20.3 Gy (P<.05) and 73.5 Gy (P=.07) for SBRT boost and total treatment, respectively. Conclusions: SBRT boost to both primary and nodal disease after chemoradiation is feasible and well tolerated. Local control rates are encouraging, especially at doses ≥24 Gy in 2 fractions. Toxicity at the PBV is a concern but potentially can be avoided with strict dose-volume constraints.« less
Stereotactic (Mammographically Guided) Breast Biopsy
... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...
Use of stereotactic intensity-modulated radiotherapy in thyroid-related ophthalmopathy. Case report.
Espinoza, Salvador; Saboori, Mehran; Forman, Scott; Moorthy, Chitti R; Benzil, Deborah L
2004-11-01
Thyroid-related ophthalmopathy (TRO), a debilitating condition involving a range of visual and orbital symptoms, occurs in up to 40% of patients with Graves disease. The goals of treatment include correcting thyroid dysfunction, relieving ocular pain, preserving vision, and improving cosmetic appearance. Options for therapy include symptomatic treatment, glucocorticoid medication, radiation therapy, and surgery. Traditional radiation treatment uses small opposed bilateral fields consisting of retrobulbar volumes and customized blocks to shield periorbital structures. The combination of intensity-modulated radiotherapy (IMRT) and stereotactic technology facilitates the administration of radiation to patients suffering from TRO and provides greater safety and efficacy than traditional treatment. The authors present the case of a patient with severe TRO whose symptoms resolved rapidly after treatment with stereotactic IMRT. The outcome in this case supports stereotactic IMRT as an effective treatment option for patients with TRO who also undergo radiation therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henke, Lauren; Kashani, Rojano; Yang, Deshan
Purpose: To characterize potential advantages of online-adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (SBRT) to treat oligometastatic disease of the non-liver abdomen and central thorax. Methods and Materials: Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR image guided RT system. The SBRT plans were created on the basis of tumor/organ at risk (OAR) anatomy at initial computed tomography simulation (P{sub I}), and simulated adaptive plans were created on the basis of observed MR image set tumor/OAR “anatomy of the day”more » (P{sub A}). Each P{sub A} was planned under workflow constraints to simulate online-adaptive RT. Prescribed dose was 50 Gy/5 fractions, with goal coverage of 95% planning target volume (PTV) by 95% of the prescription, subject to hard OAR constraints. The P{sub I} was applied to each MR dataset and compared with P{sub A} to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results: Hard OAR constraints were met for all P{sub Is} based on anatomy from initial computed tomography simulation, and all P{sub As} based on anatomy from each daily MR image set. Application of the P{sub I} to anatomy of the day caused OAR constraint violation in 19 of 30 cases. Adaptive planning increased PTV coverage in 21 of 30 cases, including 14 cases in which hard OAR constraints were violated by the nonadaptive plan. For 9 P{sub A} cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a nonadaptive setting. Conclusions: Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared with nonadaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirkpatrick, John P., E-mail: john.kirkpatrick@dm.duke.edu; Department of Surgery, Duke University, Durham, North Carolina; Wang, Zhiheng
2015-01-01
Purpose: To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Methods and Materials: Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board–approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diametersmore » less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator–based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Results: Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non–small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in neurocognition or quality of life was observed. Conclusions: SRS was well tolerated, with low rates of LR and RN in both cohorts. However, given the higher potential risk of RN with a 3-mm margin, a 1-mm GTV expansion is more appropriate.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Redmond, Kristin J., E-mail: kjanson3@jhmi.edu; Lo, Simon S.; Fisher, Charles
Postoperative stereotactic body radiation therapy (SBRT) for metastatic spinal tumors is increasingly being performed in clinical practice. Whereas the fundamentals of SBRT practice for intact spinal metastases are established, there are as yet no comprehensive practice guidelines for the postoperative indications. In particular, there are unique considerations for patient selection and treatment planning specific to postoperative spine SBRT that are critical for safe and effective management. The purpose of this critical review is to discuss the rationale for treatment, describe those factors affecting surgical decision making, introduce modern surgical trends, and summarize treatment outcomes for both conventional postoperative external beammore » radiation therapy and postoperative spine SBRT. Lastly, an in-depth practical discussion with respect to treatment planning and delivery considerations is provided to help guide optimal practice.« less
Yeung, Timothy Pok Chi; Kurdi, Maher; Wang, Yong; Al-Khazraji, Baraa; Morrison, Laura; Hoffman, Lisa; Jackson, Dwayne; Crukley, Cathie; Lee, Ting-Yim; Bauman, Glenn; Yartsev, Slav
2014-01-01
Background The therapeutic efficacy of stereotactic radiosurgery for glioblastoma is not well understood, and there needs to be an effective biomarker to identify patients who might benefit from this treatment. This study investigated the efficacy of computed tomography (CT) perfusion imaging as an early imaging biomarker of response to stereotactic radiosurgery in a malignant rat glioma model. Methods Rats with orthotopic C6 glioma tumors received either mock irradiation (controls, N = 8) or stereotactic radiosurgery (N = 25, 12 Gy in one fraction) delivered by Helical Tomotherapy. Twelve irradiated animals were sacrificed four days after stereotactic radiosurgery to assess acute CT perfusion and histological changes, and 13 irradiated animals were used to study survival. Irradiated animals with survival >15 days were designated as responders while those with survival ≤15 days were non-responders. Longitudinal CT perfusion imaging was performed at baseline and regularly for eight weeks post-baseline. Results Early signs of radiation-induced injury were observed on histology. There was an overall survival benefit following stereotactic radiosurgery when compared to the controls (log-rank P<0.04). Responders to stereotactic radiosurgery showed lower relative blood volume (rBV), and permeability-surface area (PS) product on day 7 post-stereotactic radiosurgery when compared to controls and non-responders (P<0.05). rBV and PS on day 7 showed correlations with overall survival (P<0.05), and were predictive of survival with 92% accuracy. Conclusions Response to stereotactic radiosurgery was heterogeneous, and early selection of responders and non-responders was possible using CT perfusion imaging. Validation of CT perfusion indices for response assessment is necessary before clinical implementation. PMID:25329655
Intraoperative MR-guided DBS implantation for treating PD and ET
NASA Astrophysics Data System (ADS)
Liu, Haiying; Maxwell, Robert E.; Truwit, Charles L.
2001-05-01
Deep brain stimulator (DBS) implantation is a promising treatment alternative for suppressing the motor tremor symptoms in Parkinson disease (PD) patient. The main objective is to develop a minimally invasive approach using high spatial resolution and soft-tissue contrast MR imaging techniques to guide the surgical placement of DBS. In the MR-guided procedure, the high spatial resolution MR images were obtained intra-operatively and used to target stereotactically a specific deep brain location. The neurosurgery for craniotomy was performed in the front of the magnet outside of the 10 Gauss line. Aided with positional registration assembly for the stereotactic head frame, the target location (VIM or GPi or STN) in deep brain areas was identified and measured from the MR images in reference to the markers in the calibration assembly of the head frame before the burrhole prep. In 20 patients, MR- guided DBS implantations have been performed according to the new methodology. MR-guided DBS implantation at high magnetic field strength has been shown to be feasible and desirable. In addition to the improved outcome, this offers a new surgical approach in which intra-operative visualization is possible during intervention, and any complications such as bleeding can be assessed in situ immediately prior to dural closure.
Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi
2014-01-01
Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.
Worm, Esben S; Høyer, Morten; Hansen, Rune; Larsen, Lars P; Weber, Britta; Grau, Cai; Poulsen, Per R
2018-06-01
Intrafraction motion can compromise the treatment accuracy in liver stereotactic body radiation therapy (SBRT). Respiratory gating can improve treatment delivery; however, gating based on external motion surrogates is inaccurate. The present study reports the use of Calypso-based internal electromagnetic motion monitoring for gated liver SBRT. Fifteen patients were included in a study of 3-fraction respiratory gated liver SBRT guided by 3 implanted electromagnetic transponders. The planning target volume was created by a 5-mm axial and 7-mm (n = 12) or 10-mm (n = 3) craniocaudal expansion of the clinical target volume (CTV) and covered with 67% of the prescribed CTV mean dose. Treatment was gated to the end-exhale phase of the respiratory cycle with beam-on when the target deviated <3 mm (left-right/anteroposterior) and 4 mm (craniocaudal) from the planned position, according to the monitored (25-Hz) transponder centroid position. The couch was adjusted remotely if baseline drifts >1 to 2 mm occurred. Log files of transponder motion were used to determine the geometric error and reconstruct the delivered CTV dose in the actual gated treatments and in simulated nongated treatments. No severe side effects were observed in relation to transponder implantation. All 45 treatment fractions were successfully guided using the Calypso system. The mean number of couch corrections during each gated fraction was 2.8 (range 0-7). The mean duty cycle during gated treatment was 62.5% (range 29.1%-84.9%). Without gating, the mean 3-dimensional geometric error during a fraction would have been 5.4 mm (range 2.7-12.1). Gating reduced this error to 2.0 mm (range 1.2-3.0). The patient mean reduction in minimum dose to 95% of the CTV relative to the planned dose was 6.0 percentage points (range 0.7-22.0) without gating and 0.8 percentage point (range 0.2-2.0) with gating. Gating using internal motion monitoring was successfully applied for liver SBRT. It markedly improved the geometric and dosimetric accuracy compared with nongated standard treatment. Copyright © 2018 Elsevier Inc. All rights reserved.
Unclear-onset intracerebral hemorrhage: Clinical characteristics, hematoma features, and outcomes.
Inoue, Yasuteru; Miyashita, Fumio; Koga, Masatoshi; Minematsu, Kazuo; Toyoda, Kazunori
2017-12-01
Background and purpose Although unclear-onset ischemic stroke, including wake-up ischemic stroke, is drawing attention as a potential target for reperfusion therapy, acute unclear-onset intracerebral hemorrhage has been understudied. Clinical characteristics, hematoma features, and outcomes of patients who developed intracerebral hemorrhage during sleep or those with intracerebral hemorrhage who were unconscious when witnessed were determined. Methods Consecutive intracerebral hemorrhage patients admitted within 24 hours after onset or last-known normal time were classified into clear-onset intracerebral hemorrhage and unclear-onset intracerebral hemorrhage groups. Outcomes included initial hematoma volume, initial National Institutes of Health Stroke Scale score, hematoma growth on 24-hour follow-up computed tomography, and vital and functional prognoses at 30 days. Results Of 377 studied patients (122 women, 69 ± 11 years old), 147 (39.0%) had unclear-onset intracerebral hemorrhage. Patients with unclear-onset intracerebral hemorrhage had larger hematoma volumes (p = 0.044) and higher National Institutes of Health Stroke Scale scores (p < 0.001) than those with clear-onset intracerebral hemorrhage after multivariable adjustment for risk factors and comorbidities. Hematoma growth was similarly common between the two groups (p = 0.176). There were fewer patients with modified Rankin Scale (mRS) scores of 0-2 (p = 0.033) and more patients with mRS scores of 5-6 (p = 0.009) and with fatal outcomes (p = 0.049) in unclear-onset intracerebral hemorrhage group compared with clear-onset intracerebral hemorrhage as crude values, but not after adjustment. Conclusions Patients with unclear-onset intracerebral hemorrhage presented with larger hematomas and higher National Institutes of Health Stroke Scale scores at emergent visits than those with clear-onset intracerebral hemorrhage, independent of underlying characteristics. Unclear-onset intracerebral hemorrhage patients showed poorer 30-day vital and functional outcomes than clear-onset intracerebral hemorrhage patients; these differences seem to be mainly due to initial hematoma volumes and National Institutes of Health Stroke Scale scores.
Hirshman, Brian R; Wilson, Bayard; Ali, Mir Amaan; Proudfoot, James A; Koiso, Takao; Nagano, Osamu; Carter, Bob S; Serizawa, Toru; Yamamoto, Masaaki; Chen, Clark C
2018-04-01
Two intracranial tumor volume variables have been shown to prognosticate survival of stereotactic-radiosurgery-treated brain metastasis patients: the largest intracranial tumor volume (LITV) and the cumulative intracranial tumor volume (CITV). To determine whether the prognostic value of the Scored Index for Radiosurgery (SIR) model can be improved by replacing one of its components-LITV-with CITV. We compared LITV and CITV in terms of their survival prognostication using a series of multivariable models that included known components of the SIR: age, Karnofsky Performance Score, status of extracranial disease, and the number of brain metastases. Models were compared using established statistical measures, including the net reclassification improvement (NRI > 0) and integrated discrimination improvement (IDI). The analysis was performed in 2 independent cohorts, each consisting of ∼3000 patients. In both cohorts, CITV was shown to be independently predictive of patient survival. Replacement of LITV with CITV in the SIR model improved the model's ability to predict 1-yr survival. In the first cohort, the CITV model showed an NRI > 0 improvement of 0.2574 (95% confidence interval [CI] 0.1890-0.3257) and IDI of 0.0088 (95% CI 0.0057-0.0119) relative to the LITV model. In the second cohort, the CITV model showed a NRI > 0 of 0.2604 (95% CI 0.1796-0.3411) and IDI of 0.0051 (95% CI 0.0029-0.0073) relative to the LITV model. After accounting for covariates within the SIR model, CITV offers superior prognostic value relative to LITV for stereotactic radiosurgery-treated brain metastasis patients.
Stereotactic fractionated radiotherapy for the treatment of benign meningiomas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Candish, Charles; McKenzie, Michael; Clark, Brenda G.
Purpose: To assess the use of stereotactic fractionated radiotherapy (SRT) for the treatment of meningiomas. Methods and Materials: Between April 1999 and October 2004, 38 patients underwent SRT. Of 34 patients (36 tumors) assessed, the median age was 53 years. The indication was primary treatment in 26 cases (no histology) and postoperative in 10 cases. The most common sites were cavernous sinus (17), optic nerve (6), and cerebellopontine angle (5). The median gross target volume and planning target volume were 8.9 cm{sup 3} and 18.9 cm{sup 3}, respectively. Stereotactic treatment was delivered with 6-MV photons with static conformal fields (custom-mademore » blocks, 9 patients, and micromultileaf collimator, 25 patients). Median number of fields was six. The median dose prescribed was 50 Gy (range, 45-50.4 Gy) in 28 fractions. The median homogeneity and conformality indices were 1.1 and 1.79, respectively. Results: Treatment was well tolerated. Median follow-up was 26 months with 100% progression-free survival. One patient developed an area of possible radionecrosis related to previous radiotherapy, and 2 men developed mild hypogonadism necessitating testosterone replacement. The vision of 5 of 6 patients with optic pathway meningiomas improved or remained static. Conclusions: Stereotactic fractionated radiotherapy for the treatment of meningiomas is practical, and with early follow-up, seems to be effective.« less
Doré, M; Martin, S; Delpon, G; Clément, K; Campion, L; Thillays, F
2017-02-01
To evaluate local control and adverse effects after postoperative hypofractionated stereotactic radiosurgery in patients with brain metastasis. We reviewed patients who had hypofractionated stereotactic radiosurgery (7.7Gy×3 prescribed to the 70% isodose line, with 2mm planning target volume margin) following resection from March 2008 to January 2014. The primary endpoint was local failure defined as recurrence within the surgical cavity. Secondary endpoints were distant failure rates and the occurrence of radionecrosis. Out of 95 patients, 39.2% had metastatic lesions from a non-small cell lung cancer primary tumour. The median Graded Prognostic Assessment score was 3 (48% of patients). One-year local control rates were 84%. Factors associated with improved local control were no cavity enhancement on pre-radiation MRI (P<0.00001), planning target volume less than 12cm 3 (P=0.005), Graded Prognostic Assessment score 2 or above (P=0.009). One-year distant cerebral control rates were 56%. Thirty-three percent of patients received whole brain radiation therapy. Histologically proven radionecrosis of brain tissue occurred in 7.2% of cases. The size of the preoperative lesion and the volume of healthy brain tissue receiving 21Gy (V 21 ) were both predictive of the incidence of radionecrosis (P=0.010 and 0.036, respectively). Adjuvant hypofractionated stereotactic radiosurgery to the postoperative cavity in patients with brain metastases results in excellent local control in selected patients, helps delay the use of whole brain radiation, and is associated with a relatively low risk of radionecrosis. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haasbeek, Cornelis J.A.; Lagerwaard, Frank J.; Cuijpers, Johan P.
2007-04-01
Purpose: Changes in position or size of target volumes have been observed during radiotherapy for lung cancer. The need for adaptive treatment planning during stereotactic radiotherapy of Stage I tumors was retrospectively analyzed using repeat four-dimensional computed tomography (4DCT) scans. Methods and Materials: A planning study was performed for 60 tumors in 59 patients using 4DCT scans repeated after two or more treatment fractions. Planning target volumes (PTV) encompassed all tumor mobility, and dose distributions from the initial plan were projected onto PTVs derived from the repeat 4DCT. A dosimetric and volumetric analysis was performed. Results: The repeat 4DCT scansmore » were performed at a mean of 6.6 days (range, 2-12 days) after the first fraction of stereotactic radiotherapy. In 25% of cases the repeat PTV was larger, but the difference exceeded 1 mL in 5 patients only. The mean 3D displacement between the center of mass of both PTVs was 2.0 mm. The initial 80% prescription isodose ensured a mean coverage of 98% of repeat PTVs, and this isodose fully encompassed the repeat internal target volumes in all but 1 tumor. 'Inadequate' coverage in the latter was caused by a new area of atelectasis adjacent to the tumor on the repeat 4DCT. Conclusions: Limited 'time trends' were observed in PTVs generated by repeated uncoached 4DCT scans, and the dosimetric consequences proved to be minimal. Treatment based only on the initial PTV would not have resulted in major tumor underdosage, indicating that adaptive treatment planning is of limited value for fractionated stereotactic radiotherapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vikraman, S; Rajesh, Thiyagarajan; Karrthick, Kp
2015-06-15
Purpose: The purpose of this study was to evaluate multiple brain metastases stereotactic treatment planning of Cyberknife versus linac using dose volume based indices. Methods: Fifteen multiple brain metastases patients were taken for this study from Cyberknife Multiplan TPSv4.6.0. All these patients underwent stereotactic treatment in Cyberknife. For each patient VMAT stereotactic treatment plan was generated in MONACO TPSv5.0 using Elekta beam modulator MLC and matched the delivered plan. A median dose of 8.5Gy(range 7–12Gy) per fraction was prescribed. Tumor volume was in the range of 0.06–4.33cc. Treatment plan quality was critically evaluated by comparing DVH indices such as D98,more » D95, CI, and HI for target volumes. Maximum point doses and volume doses were evaluated for critical organs. Results: For each case, target coverage of D98 was achieved with 100% prescription dose with SD of 0.29% and 0.41% in Linac and Cyberknife respectively. The average conformity index(CI) of 1.26±0.0796 SD for Cyberknife and 1.92±0.60SD for linac were observed. Better homogeneity Index (HI) of 1.17±0.09SD was observed in linac as compared to Cyberknife HI of 1.24±0.05SD.All the critical organ doses were well within tolerance limit in both linac and Cyberknife plans. There is no significant difference of maximum point doses for brainstem and optic chiasm. Treatment time and number of monitor units are more in Cyberknife compared to linac. The average volume receiving 12Gy in whole brain was 6% and 12% for Cyberknife and linac respectively. 1000cc of whole brain received 60% lesser dose in Linac compared to Cyberknife in all cases. Conclusion: The study shows that dosimetrically comparable plans are achievable Cyberknife and Linac. However, a better conformity, target coverage, lesser OAR dose is achieved with Cyberknife due to greater degrees of freedom with robotic gantry and smaller collimator for multiple targets.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Algan, Ozer, E-mail: oalgan@ouhsc.edu; Giem, Jared; Young, Julie
To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)–based or multiple isocenter (MI)–based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A totalmore » of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63 mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V{sub 100}. All of the other measured dosimetric parameters including the V{sub 95}, V{sub 99}, and D{sub 100} were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.« less
Algan, Ozer; Giem, Jared; Young, Julie; Ali, Imad; Ahmad, Salahuddin; Hossain, Sabbir
2015-01-01
To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiation therapy using a single isocenter (SI)-based or multiple isocenter (MI)-based treatment planning in patients with less than 4 brain metastases. In total, 10 patients with magnetic resonance imaging (MRI) demonstrating 2-3 brain metastases were included in this retrospective study, and 2 sets of stereotactic intensity-modulated radiation therapy (IMRT) treatment plans (SI vs MI) were generated. The hippocampus was contoured on SPGR sequences, and doses received by the hippocampus and the brain were calculated and compared between the 2 treatment techniques. A total of 23 lesions in 10 patients were evaluated. The median tumor volume, the right hippocampus volume, and the left hippocampus volume were 3.15, 3.24, and 2.63mL, respectively. In comparing the 2 treatment plans, there was no difference in the planning target volume (PTV) coverage except in the tail for the dose-volume histogram (DVH) curve. The only statistically significant dosimetric parameter was the V100. All of the other measured dosimetric parameters including the V95, V99, and D100 were not significantly different between the 2 treatment planning techniques. None of the dosimetric parameters evaluated for the hippocampus revealed any statistically significant difference between the MI and SI plans. The total brain doses were slightly higher in the SI plans, especially in the lower dose region, although this difference was not statistically different. The use of SI-based treatment plan resulted in a 35% reduction in beam-on time. The use of SI treatments for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain when compared with MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, Daniel, E-mail: Daniel.Pham@petermac.org; Kron, Tomas; Foroudi, Farshad
2013-10-01
Stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) targets requires motion management strategies to verify dose delivery. This case study highlights the effect of a change in patient breathing amplitude on the dosimetry to organs at risk and target structures. A 73-year-old male patient was planned for receiving 26 Gy of radiation in 1 fraction of SABR for a left primary RCC. The patient was simulated with four-dimensional computed tomography (4DCT) and the tumor internal target volume (ITV) was delineated using the 4DCT maximum intensity projection. However, the initially planned treatment was abandoned at the radiation oncologist'smore » discretion after pretreatment cone-beam CT (CBCT) motion verification identified a greater than 50% reduction in superior to inferior diaphragm motion as compared with the planning 4DCT. This patient was resimulated with respiratory coaching instructions. To assess the effect of the change in breathing on the dosimetry to the target, each plan was recalculated on the data set representing the change in breathing condition. A change from smaller to larger breathing showed a 46% loss in planning target volume (PTV) coverage, whereas a change from larger breathing to smaller breathing resulted in an 8% decrease in PTV coverage. ITV coverage was similarly reduced by 8% in both scenarios. This case study highlights the importance of tools to verify breathing motion prior to treatment delivery. 4D image guided radiation therapy verification strategies should focus on not only verifying ITV margin coverage but also the effect on the surrounding organs at risk.« less
Batchelor, Connor; Pordeli, Pooneh; d'Esterre, Christopher D; Najm, Mohamed; Al-Ajlan, Fahad S; Boesen, Mari E; McDougall, Connor; Hur, Lisa; Fainardi, Enrico; Shankar, Jai Jai Shiva; Rubiera, Marta; Khaw, Alexander V; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Goyal, Mayank; Lee, Ting-Yim; Aviv, Richard I; Menon, Bijoy K
2017-06-01
Intracerebral hemorrhage is a feared complication of intravenous alteplase therapy in patients with acute ischemic stroke. We explore the use of multimodal computed tomography in predicting this complication. All patients were administered intravenous alteplase with/without intra-arterial therapy. An age- and sex-matched case-control design with classic and conditional logistic regression techniques was chosen for analyses. Outcome was parenchymal hemorrhage on 24- to 48-hour imaging. Exposure variables were imaging (noncontrast computed tomography hypoattenuation degree, relative volume of very low cerebral blood volume, relative volume of cerebral blood flow ≤7 mL/min·per 100 g, relative volume of T max ≥16 s with all volumes standardized to z axis coverage, mean permeability surface area product values within T max ≥8 s volume, and mean permeability surface area product values within ipsilesional hemisphere) and clinical variables (NIHSS [National Institutes of Health Stroke Scale], onset to imaging time, baseline systolic blood pressure, blood glucose, serum creatinine, treatment type, and reperfusion status). One-hundred eighteen subjects (22 patients with parenchymal hemorrhage versus 96 without, median baseline NIHSS score of 15) were included in the final analysis. In multivariable regression, noncontrast computed tomography hypoattenuation grade ( P <0.006) and computerized tomography perfusion white matter relative volume of very low cerebral blood volume ( P =0.04) were the only significant variables associated with parenchymal hemorrhage on follow-up imaging (area under the curve, 0.73; 95% confidence interval, 0.63-0.83). Interrater reliability for noncontrast computed tomography hypoattenuation grade was moderate (κ=0.6). Baseline hypoattenuation on noncontrast computed tomography and very low cerebral blood volume on computerized tomography perfusion are associated with development of parenchymal hemorrhage in patients with acute ischemic stroke receiving intravenous alteplase. © 2017 American Heart Association, Inc.
Fortes Lima, Telmo Tiburcio; Prandini, Mirto Nelso; Gallo, Pasquale; Cavalheiro, Sérgio
2012-04-01
The literature is controversial on whether intraventricular bleeding has a negative impact on the prognosis of spontaneous intracerebral hemorrhage. Nevertheless, an association between intraventricular bleeding and spontaneous intracerebral hemorrhage volumes has been consistently reported. To evaluate the prognostic value of intraventricular bleeding in deep intraparenchymal hypertensive spontaneous hemorrhage with a bleeding volume <30 cm(3). Of the 320 patients initially evaluated, 33 met the inclusion criteria and were enrolled in this prospective study. The volume of intraparenchymal hemorrhage was calculated by brain computed tomography (CT) image analysis, and the volume of intraventricular bleeding was calculated by the LeRoux scale. Clinical data, including neurological complications, were collected daily during hospitalization. Neurological outcome was evaluated 30 days after the event by using the Glasgow outcome scale. Patients were assigned to 1 of 3 groups according to intraventricular bleeding: Control, no intraventricular bleeding; LR 1, intraventricular bleeding with LeRoux scale scores of 1 to 8; or LR 2, intraventricular bleeding with LeRoux scale scores >8. There were no significant differences among groups concerning age, mean blood pressure, and time from onset to brain CT scan. Patients with greater intraventricular bleeding presented lower initial Glasgow coma scale scores, increased ventricular index and width of temporal horns, increased number of clinical and neurological complications, and longer hospitalization. Furthermore, their relative risk for unfavorable clinical outcome was 1.9 (95% confidence interval 1.25-2.49). Intraventricular bleeding with a LeRoux scale score >8 appears to have a negative effect on deep spontaneous intraparenchymal cerebral hemorrhage of small volume.
Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.
Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr
2017-01-01
Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.
Radiation Therapy and Hearing Loss
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandare, Niranjan; Jackson, Andrew; Eisbruch, Avraham
2010-03-01
A review of literature on the development of sensorineural hearing loss after high-dose radiation therapy for head-and-neck tumors and stereotactic radiosurgery or fractionated stereotactic radiotherapy for the treatment of vestibular schwannoma is presented. Because of the small volume of the cochlea a dose-volume analysis is not feasible. Instead, the current literature on the effect of the mean dose received by the cochlea and other treatment- and patient-related factors on outcome are evaluated. Based on the data, a specific threshold dose to cochlea for sensorineural hearing loss cannot be determined; therefore, dose-prescription limits are suggested. A standard for evaluating radiation therapy-associatedmore » ototoxicity as well as a detailed approach for scoring toxicity is presented.« less
Foster, John C; Sappenfield, Joshua W; Smith, Robert S; Kiley, Sean P
2017-12-01
The advent of massive transfusion protocols (MTP) has had a significant positive impact on hemorrhaging trauma patient morbidity and mortality. Nevertheless, societal MTP guidelines and individual MTPs at academic institutions continue to circulate opposing recommendations on topics critical to MTPs. This narrative review discusses up-to-date information on 2 such topics, the initiation and termination of an MTP. The discussion for each begins with a review of the recommendations and supporting literature presented by MTP guidelines from 3 prominent societies, the American Society of Anesthesiologists, the American College of Surgeons, and the task force for Advanced Bleeding Care in Trauma. This is followed by an in-depth analysis of the main components within those recommendations. Societal recommendations on MTP initiation in hemorrhaging trauma patients emphasize the use of retrospectively validated massive transfusion (MT) prediction score, specifically, the Assessment of Blood Consumption and Trauma-Associated Severe Hemorrhage scores. Validation studies have shown that both scoring systems perform similarly. Both scores reliably identify patients that will not require an MT, while simultaneously overpredicting MT requirements. However, each scoring system has its unique advantages and disadvantages, and this review discusses how specific aspects of each scoring system can affect widespread applicability and statistical performance. In addition, we discuss the often overlooked topic of initiating MT in nontrauma patients and the specific tools physicians have to guide the MT initiation decision in this unique setting. Despite the serious complications that can arise with transfusion of large volumes of blood products, there is considerably less research pertinent to the topic of MTP termination. Societal recommendations on MTP termination emphasize applying clinical reasoning to identify patients who have bleeding source control and are adequately resuscitated. This review, however, focuses primarily on the recommendations presented by the Advanced Bleeding Care in Trauma's MTP guidelines that call for prompt termination of the algorithm-guided model of resuscitation and rapidly transitioning into a resuscitation model guided by laboratory test results. We also discuss the evidence in support of laboratory result-guided resuscitation and how recent literature on viscoelastic hemostatic assays, although limited, highlights the potential to achieve additional benefits from this method of resuscitation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magnelli, A; Xia, P
2015-06-15
Purpose: Spine stereotactic body radiotherapy requires very conformal dose distributions and precise delivery. Prior to treatment, a KV cone-beam CT (KV-CBCT) is registered to the planning CT to provide image-guided positional corrections, which depend on selection of the region of interest (ROI) because of imperfect patient positioning and anatomical deformation. Our objective is to determine the dosimetric impact of ROI selections. Methods: Twelve patients were selected for this study with the treatment regions varied from C-spine to T-spine. For each patient, the KV-CBCT was registered to the planning CT three times using distinct ROIs: one encompassing the entire patient, amore » large ROI containing large bony anatomy, and a small target-focused ROI. Each registered CBCT volume, saved as an aligned dataset, was then sent to the planning system. The treated plan was applied to each dataset and dose was recalculated. The tumor dose coverage (percentage of target volume receiving prescription dose), maximum point dose to 0.03 cc of the spinal cord, and dose to 10% of the spinal cord volume (V10) for each alignment were compared to the original plan. Results: The average magnitude of tumor coverage deviation was 3.9%±5.8% with external contour, 1.5%±1.1% with large ROI, 1.3%±1.1% with small ROI. Spinal cord V10 deviation from plan was 6.6%±6.6% with external contour, 3.5%±3.1% with large ROI, and 1.2%±1.0% with small ROI. Spinal cord max point dose deviation from plan was: 12.2%±13.3% with external contour, 8.5%±8.4% with large ROI, and 3.7%±2.8% with small ROI. Conclusion: A small ROI focused on the target results in the smallest deviation from planned dose to target and cord although rotations at large distances from the targets were observed. It is recommended that image fusion during CBCT focus narrowly on the target volume to minimize dosimetric error. Improvement in patient setups may further reduce residual errors.« less
Glass, Todd F; Knapp, Jason; Amburn, Philip; Clay, Bruce A; Kabrisky, Matt; Rogers, Steven K; Garcia, Victor F
2004-02-01
To determine whether a prototype artificial intelligence system can identify volume of hemorrhage in a porcine model of controlled hemorrhagic shock. Prospective in vivo animal model of hemorrhagic shock. Research foundation animal surgical suite; computer laboratories of collaborating industry partner. Nineteen, juvenile, 25- to 35-kg, male and female swine. Anesthetized animals were instrumented for arterial and systemic venous pressure monitoring and blood sampling, and a splenectomy was performed. Following a 1-hr stabilization period, animals were hemorrhaged in aliquots to 10, 20, 30, 35, 40, 45, and 50% of total blood volume with a 10-min recovery between each aliquot. Data were downloaded directly from a commercial monitoring system into a proprietary PC-based software package for analysis. Arterial and venous blood gas values, glucose, and cardiac output were collected at specified intervals. Electrocardiogram, electroencephalogram, mixed venous oxygen saturation, temperature (core and blood), mean arterial pressure, pulmonary artery pressure, central venous pressure, pulse oximetry, and end-tidal CO(2) were continuously monitored and downloaded. Seventeen of 19 animals (89%) died as a direct result of hemorrhage. Stored data streams were analyzed by the prototype artificial intelligence system. For this project, the artificial intelligence system identified and compared three electrocardiographic features (R-R interval, QRS amplitude, and R-S interval) from each of nine unknown samples of the QRS complex. We found that the artificial intelligence system, trained on only three electrocardiographic features, identified hemorrhage volume with an average accuracy of 91% (95% confidence interval, 84-96%). These experiments demonstrate that an artificial intelligence system, based solely on the analysis of QRS amplitude, R-R interval, and R-S interval of an electrocardiogram, is able to accurately identify hemorrhage volume in a porcine model of lethal hemorrhagic shock. We suggest that this technology may represent a noninvasive means of assessing the physiologic state during and immediately following hemorrhage. Point of care application of this technology may improve outcomes with earlier diagnosis and better titration of therapy of shock.
Osawa, Aiko; Maeshima, Shinichiro
2016-04-01
Thalamic hemorrhages are associated with a variety of cognitive dysfunctions, and it is well known that such cognitive changes constitute a limiting factor of recovery of the activities of daily living (ADL). The relationship between cognitive dysfunction and hematomas is unclear. In this study, we investigated the relationship between aphasia/neglect and hematoma volume, hematoma type, and the ADL. One hundred fifteen patients with thalamic hemorrhage (70 men and 45 women) were studied. Their mean age was 68.9 ± 10.3 years, and patients with both left and right lesions were included. We calculated hematoma volume and examined the presence or absence of aphasia/neglect and the relationships between these dysfunctions and hematoma volume, hematoma type, and the ADL. Fifty-nine patients were found to have aphasia and 35 were found to have neglect. Although there was no relationship between hematoma type and cognitive dysfunction, hematoma volume showed a correlation with the severity of cognitive dysfunction. The ADL score and ratio of patient discharge for patients with aphasia/neglect were lower than those for patients without aphasia/neglect. We observed a correlation between the hematoma volume in thalamic hemorrhage and cognitive dysfunction. Aphasia/neglect is found frequently in patients with acute thalamic hemorrhage and may influence the ADL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, D.W. Nathan; Cho, L. Chinsoo; Straka, Christopher
2014-07-01
Purpose: To convey the occurrence of isolated cases of severe rectal toxicity at the highest dose level tested in 5-fraction stereotactic body radiation therapy (SBRT) for localized prostate cancer; and to rationally test potential causal mechanisms to guide future studies and experiments to aid in mitigating or altogether avoiding such severe bowel injury. Methods and Materials: Clinical and treatment planning data were analyzed from 91 patients enrolled from 2006 to 2011 on a dose-escalation (45, 47.5, and 50 Gy in 5 fractions) phase 1/2 clinical study of SBRT for localized prostate cancer. Results: At the highest dose level, 6.6% ofmore » patients treated (6 of 91) developed high-grade rectal toxicity, 5 of whom required colostomy. Grade 3+ delayed rectal toxicity was strongly correlated with volume of rectal wall receiving 50 Gy >3 cm{sup 3} (P<.0001), and treatment of >35% circumference of rectal wall to 39 Gy (P=.003). Grade 2+ acute rectal toxicity was significantly correlated with treatment of >50% circumference of rectal wall to 24 Gy (P=.010). Conclusion: Caution is advised when considering high-dose SBRT for treatment of tumors near bowel structures, including prostate cancer. Threshold dose constraints developed from physiologic principles are defined, and if respected can minimize risk of severe rectal toxicity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Jen-San, E-mail: jen-san.tsai@verizon.net; Micaily, Bizhan; Miyamoto, Curtis
2012-10-01
To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotationalmore » axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement {+-} 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2-2.5 cGy for anatomic diameters 15-33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 {+-} 3.0 mm, 0.5 {+-} 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 {+-} 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within {+-} 4.5 mm coordinates shifting. IGRT using XVIcbs is critical to IMRT for prostate and H and N, especially SRT, SRS, and SBRT. To optimize this modality of IGRT, a vigilant QA program is indispensable. Prostate IGRT reveals treatment accuracy as subject to coordinates' adjustments; otherwise a 4.5-mm margin is required to allow for full dose coverage of the clinical target volume, notwithstanding toxicity to normal tissues.« less
Liu, Liangming; Tian, Kunlun; Zhu, Yu; Ding, Xiaoli; Li, Tao
2013-08-01
Fluid resuscitation is the essential step for early treatment of traumatic hemorrhagic shock. However, its implementation is greatly limited before hospital or during evacuation. The authors investigated whether δ opioid receptor antagonist ICI 174,864 was suitable for the early treatment of traumatic hemorrhagic shock. With uncontrolled hemorrhagic-shock rats, the antishock effects of six dosages of ICI 174,864 (0.1, 0.3, 0.5, 1, 3, and 5 mg/kg) infused with or without a small volume of lactated Ringer's solution (LR) before bleeding controlled or bleeding cessation at different times were observed. ICI 174,864 (0.1-3 mg/kg) with or without 1/4 volume of LR infusion showed dose-dependent increase in the mean arterial blood pressure, and significantly prolonged the survival time and 8-h survival rate, as compared with ICI 174,864 plus 1/2 volume of LR infusion. The best effect was shown with 3 mg/kg of ICI 174,864. Bleeding cessation at 1, 2, or 3 h during infusion of ICI 174,864 (3 mg/kg) plus 1/4 volume of LR improved subsequent treatment (70% 24-h survival rate vs. 50 and 10% 24-h survival rate in hypotensive resuscitation and LR group, respectively). There was significant improvement in hemodynamic parameters, oxygen delivery, and tissue perfusion of hemorrhagic-shock rats with 3 mg/kg of ICI 174,864 plus 1/4 volume of LR infusion. δ Opioid receptor antagonist ICI 174,864 alone or with small volume of fluid infusion has good beneficial effect on uncontrolled hemorrhagic shock. Its early application can "buy" time for subsequent treatment of traumatic shock.
Chan, Alvin Y; Tran, Diem Kieu T; Gill, Amandip S; Hsu, Frank P K; Vadera, Sumeet
2016-10-01
Laser interstitial thermal therapy (LITT) is a minimally invasive procedure used to treat a variety of intracranial lesions. Utilization of robotic assistance with stereotactic procedures has gained attention due to potential for advantages over conventional techniques. The authors report the first case in which robot-assisted MRI-guided LITT was used to treat radiation necrosis in the posterior fossa, specifically within the cerebellar peduncle. The use of a stereotactic robot allowed the surgeon to perform LITT using a trajectory that would be extremely difficult with conventional arc-based techniques. A 60-year-old man presented with facial weakness and brainstem symptoms consistent with radiation necrosis. He had a history of anaplastic astrocytoma that was treated with CyberKnife radiosurgery 1 year prior to presentation, and he did well for 11 months until his symptoms recurred. The location and form of the lesion precluded excision but made the patient a suitable candidate for LITT. The location and configuration of the lesion required a trajectory for LITT that was too low for arc-based stereotactic navigation, and thus the ROSA robot (Medtech) was used. Using preoperative MRI acquisitions, the lesion in the posterior fossa was targeted. Bone fiducials were used to improve accuracy in registration, and the authors obtained an intraoperative CT image that was then fused with the MR image by the ROSA robot. They placed the laser applicator and then ablated the lesion under real-time MR thermometry. There were no complications, and the patient tolerated the procedure well. Postoperative 2-month MRI showed complete resolution of the lesion, and the patient had some improvement in symptoms.
Glasser, Seth A; Charney, Sarah; Dervisis, Nikolaos G; Witten, Matthew R; Ettinger, Susan; Berg, Jason; Joseph, Richard
2014-01-01
An image-guided robotic stereotactic radiosurgery (SRS) system can be used to deliver curative-intent radiation in either single fraction or hypofractionated doses. Medical records for 19 dogs with nonlymphomatous nasal tumors treated with hypofractionated image-guided robotic stereotactic body radiotherapy (SBRT), either with or without adjunctive treatment, were retrospectively analyzed for survival and prognostic factors. Median survival time (MST) was evaluated using Kaplan-Meier survival curves. Age, breed, tumor type, stage, tumor size, prescribed radiation dose, and heterogeneity index were analyzed for prognostic significance. Dogs were treated with three consecutive-day, 8-12 gray (Gy) fractions of image-guided robotic SBRT. Overall MST was 399 days. No significant prognostic factors were identified. Acute side effects were rare and mild. Late side effects included one dog with an oronasal fistula and six dogs with seizures. In three of six dogs, seizures were a presenting complaint prior to SBRT. The cause of seizures in the remaining three dogs could not be definitively determined due to lack of follow-up computed tomography (CT) imaging. The seizures could have been related to either progression of disease or late radiation effect. Results indicate that image-guided robotic SBRT, either with or without adjunctive therapy, for canine nonlymphomatous nasal tumors provides comparable survival times (STs) to daily fractionated megavoltage radiation with fewer required fractions and fewer acute side effects.
Investigation of the usefulness of fluorescein sodium fluorescence in stereotactic brain biopsy.
Thien, Ady; Han, Julian Xinguang; Kumar, Krishan; Ng, Yew Poh; Rao, Jai Prashanth; Ng, Wai Hoe; King, Nicolas Kon Kam
2018-02-01
Intraoperative frozen section assessment, to confirm acquisition of pathological tissues, is used in stereotactic brain biopsy to minimise sampling errors. Limitations include the dependence on dedicated neuro-oncology pathologists and an increase in operative duration. We investigated the use of intraoperative fluorescein sodium, and compared it to frozen section assessment, for confirming pathological tissue samples in the stereotactic biopsy of gadolinium-contrast-enhancing brain lesions. This prospective observational study consisted of 18 consecutive patients (12 men; median age, 63 years) who underwent stereotactic biopsy of gadolinium-contrast-enhancing brain lesions with intravenous fluorescein sodium administration. Twenty-three specimens were obtained and examined for the presence of fluorescence using a microscope with fluorescence visualisation capability. Positive and negative predictive values were calculated based on the fluorescence status of the biopsy samples with its corresponding intraoperative frozen section and definitive histopathological diagnosis. Nineteen specimens (83%) were fluorescent and four (17%) were non-fluorescent. All 19 fluorescent specimens were confirmed to be lesional on intraoperative frozen section assessment and were suitable for histopathological diagnosis. Three of the non-fluorescent specimens were confirmed to be lesional on intraoperative frozen section assessment. One non-fluorescent specimen was non-diagnostic on frozen section and histological assessments. The positive predictive value was 100% and the negative predictive value was 25%. Fluorescein sodium fluorescence is as accurate as frozen section assessment in confirming sampling of pathological tissue in the stereotactic biopsy of gadolinium-contrast-enhancing brain lesions. Fluorescein sodium fluorescence-guided stereotactic biopsy is a useful addition to the neurosurgical armamentarium.
Normal tissue toxicity after small field hypofractionated stereotactic body radiation.
Milano, Michael T; Constine, Louis S; Okunieff, Paul
2008-10-31
Stereotactic body radiation (SBRT) is an emerging tool in radiation oncology in which the targeting accuracy is improved via the detection and processing of a three-dimensional coordinate system that is aligned to the target. With improved targeting accuracy, SBRT allows for the minimization of normal tissue volume exposed to high radiation dose as well as the escalation of fractional dose delivery. The goal of SBRT is to minimize toxicity while maximizing tumor control. This review will discuss the basic principles of SBRT, the radiobiology of hypofractionated radiation and the outcome from published clinical trials of SBRT, with a focus on late toxicity after SBRT. While clinical data has shown SBRT to be safe in most circumstances, more data is needed to refine the ideal dose-volume metrics.
Transcranial Duplex Sonography Predicts Outcome following an Intracerebral Hemorrhage.
Camps-Renom, P; Méndez, J; Granell, E; Casoni, F; Prats-Sánchez, L; Martínez-Domeño, A; Guisado-Alonso, D; Martí-Fàbregas, J; Delgado-Mederos, R
2017-08-01
Several radiologic features such as hematoma volume are related to poor outcome following an intracerebral hemorrhage and can be measured with transcranial duplex sonography. We sought to determine the prognostic value of transcranial duplex sonography in patients with intracerebral hemorrhage. We conducted a prospective study of patients diagnosed with spontaneous intracerebral hemorrhage. Transcranial duplex sonography examinations were performed within 2 hours of baseline CT, and we recorded the following variables: hematoma volume, midline shift, third ventricle and lateral ventricle diameters, and the pulsatility index in both MCAs. We correlated these data with the CT scans and assessed the prognostic value of the transcranial duplex sonography measurements. We assessed early neurologic deterioration during hospitalization and mortality at 1-month follow-up. We included 35 patients with a mean age of 72.2 ± 12.8 years. Median baseline hematoma volume was 9.85 mL (interquartile range, 2.74-68.29 mL). We found good agreement and excellent correlation between transcranial duplex sonography and CT when measuring hematoma volume ( r = 0.791; P < .001) and midline shift ( r = 0.827; P < .001). The logistic regression analysis with transcranial duplex sonography measurements showed that hematoma volume was an independent predictor of early neurologic deterioration (OR, 1.078; 95% CI, 1.023-1.135) and mortality (OR, 1.089; 95% CI, 1.020-1.160). A second regression analysis with CT variables also demonstrated that hematoma volume was associated with early neurologic deterioration and mortality. When we compared the rating operation curves of both models, their predictive power was similar. Transcranial duplex sonography showed an excellent correlation with CT in assessing hematoma volume and midline shift in patients with intracerebral hemorrhage. Hematoma volume measured with transcranial duplex sonography was an independent predictor of poor outcome. © 2017 by American Journal of Neuroradiology.
Rafii, Michael S; Tuszynski, Mark H; Thomas, Ronald G; Barba, David; Brewer, James B; Rissman, Robert A; Siffert, Joao; Aisen, Paul S
2018-03-26
Nerve growth factor (NGF) is an endogenous neurotrophic factor that prevents the death and augments the functional state of cholinergic neurons of the basal forebrain, a cell population that undergoes extensive degeneration in Alzheimer disease (AD). To determine whether stereotactically guided intracerebral injections of adeno-associated viral vector (serotype 2)-nerve growth factor (AAV2-NGF) are well tolerated and exhibit preliminary evidence of impact on cognitive decline in mild to moderate AD-associated dementia. In a multicenter phase 2 trial, 49 participants with mild to moderate AD were randomly assigned in a 1:1 ratio to receive stereotactically guided intracerebral injections of AAV2-NGF or sham surgery. Participants were enrolled between November 2009 and December 2012. Analyses began in February 2015. The study was conducted at 10 US academic medical centers. Eligibility required a diagnosis of mild to moderate dementia due to AD and individuals aged 55 to 80 years. A total of 39 participants did not pass screening; the most common reason was Mini-Mental State Examination scores below cutoff. Analyses were intention-to-treat. Stereotactically guided intracerebral injections of AAV2-NGF into the nucleus basalis of Meynert of each hemisphere or sham surgery. Change from baseline on the Alzheimer Disease Assessment Scale-cognitive subscale at month 24. Among 49 participants, 21 (43%) were women, 42 (86%) self-identified as white, and the mean (SD) age was 68 (6.4) years. AAV2-NGF was safe and well-tolerated through 24 months. No significant difference was noted between the treatment group and placebo on the primary outcome measure, the Alzheimer Disease Assessment Scale-cognitive subscale (mean [SD] score, 14.52 [4.66] vs 9.11 [4.65], P = .17). This multicenter randomized clinical trial demonstrated the feasibility of sham-surgery-controlled stereotactic gene delivery studies in patients with AD. AAV2-NGF delivery was well-tolerated but did not affect clinical outcomes or selected AD biomarkers. Pathological confirmation of accurate gene targeting is needed. clinicaltrials.gov Identifier NCT00876863.
Carcel, Cheryl; Sato, Shoichiro; Zheng, Danni; Heeley, Emma; Arima, Hisatomi; Yang, Jie; Wu, Guojun; Chen, Guofang; Zhang, Shihong; Delcourt, Candice; Lavados, Pablo; Robinson, Thompson; Lindley, Richard I; Wang, Xia; Chalmers, John; Anderson, Craig S
2016-07-01
To determine the association of hyponatremia at presentation with clinical and imaging outcomes in patients with acute intracerebral hemorrhage. Retrospective pooled analysis of prospectively collected data from 3,243 participants of the pilot and main phases of the Intensive Blood Pressure Reduction in Acute Cerebral Hemorrhage Trials 1 and 2 (international, multicenter, open, blinded endpoint, randomized controlled trials designed to assess the effects of early intensive blood pressure lowering in patients with acute intracerebral hemorrhage). Clinical hospital sites in 21 countries. Patients with predominantly mild-moderate severity of spontaneous intracerebral hemorrhage within 6 hours of onset and elevated systolic blood pressure (150-220 mm Hg) were included in the study. Patients were assigned to receive intensive (target systolic blood pressure, < 140 mm Hg within 1 hr) or guideline-recommended (target systolic blood pressure, < 180 mm Hg) blood pressure-lowering therapy. Presentation hyponatremia was defined as serum sodium less than 135 mEq/L. The primary outcome was death at 90 days. Multivariable logistic regression was used to assess the association of hyponatremia with important clinical events. Of 3,002 patients with available data, 349 (12%) had hyponatremia. Hyponatremia was associated with death (18% vs 11%; multivariable-adjusted odds ratio, 1.81; 95% CI, 1.28-2.57; p < 0.001) and larger baseline intracerebral hemorrhage volume (multivariable adjusted, p = 0.046) but not with baseline perihematomal edema volume nor with growth of intracerebral hemorrhage or perihematomal edema during the initial 24 hours. Hyponatremia at presentation is associated with increased mortality in patients with predominantly deep and modest volume intracerebral hemorrhage through mechanisms that seem independent of growth in intracerebral hemorrhage or perihematomal edema.
Boda-Heggemann, Judit; Haneder, Stefan; Ehmann, Michael; Sihono, Dwi Seno Kuncoro; Wertz, Hansjörg; Mai, Sabine; Kegel, Stefan; Heitmann, Sigrun; von Swietochowski, Sandra; Lohr, Frank; Wenz, Frederik
2015-01-01
Target-volume definition for prostate cancer in patients with bilateral metal total hip replacements (THRs) is a challenge because of metal artifacts in the planning computed tomography (CT) scans. Magnetic resonance imaging (MRI) can be used for matching and prostate delineation; however, at a spatial and temporal distance from the planning CT, identical rectal and vesical filling is difficult to achieve. In addition, MRI may also be impaired by metal artifacts, even resulting in spatial image distortion. Here, we present a method to define prostate target volumes based on ultrasound images acquired during CT simulation and online-matched to the CT data set directly at the planning CT. A 78-year-old patient with cT2cNxM0 prostate cancer with bilateral metal THRs was referred to external beam radiation therapy. T2-weighted MRI was performed on the day of the planning CT with preparation according to a protocol for reproducible bladder and rectal filling. The planning CT was obtained with the immediate acquisition of a 3-dimensional ultrasound data set with a dedicated stereotactic ultrasound system for online intermodality image matching referenced to the isocenter by ceiling-mounted infrared cameras. MRI (offline) and ultrasound images (online) were thus both matched to the CT images for planning. Daily image guided radiation therapy (IGRT) was performed with transabdominal ultrasound and compared with cone beam CT. Because of variations in bladder and rectal filling and metal-induced image distortion in MRI, soft-tissue-based matching of the MRI to CT was not sufficient for unequivocal prostate target definition. Ultrasound-based images could be matched, and prostate, seminal vesicles, and target volumes were reliably defined. Daily IGRT could be successfully completed with transabdominal ultrasound with good accordance between cone beam CT and ultrasound. For prostate cancer patients with bilateral THRs causing artifacts in planning CTs, ultrasound referenced to the isocenter of the CT simulator and acquired with intermodal online coregistration directly at the planning CT is a fast and easy method to reliably delineate the prostate and target volumes and for daily IGRT. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
2011-01-01
Background Spontaneous intracerebral hemorrhage (ICH) is a devastating form of stroke with the high mortality twofold to sixfold higher than that for ischemic stroke. But the treatment of haematomas within the basal ganglia continues to be a matter of debate among neurologists and neurosurgeons. The purpose of this study is to judge the clinical value of minimally invasive stereotactic puncture therapy (MISPT) on acute ICH. Methods A prospective controlled study was undertaken. The clinical trial was in compliance with the WMA Declaration of Helsinki - Ethical Principles for Medical Research Involving Human Subjects. According to the enrollment criterion, there were 168 acute ICH cases analyzed, of which 90 cases were performed by MISPT ( MISPT group, MG) and 78 cases by Conventional craniotomy (CC group, CG), by means of compare of Glasgow Coma Scale(GCS) score, postoperative complications(PC) and rebleeding incidence(RI), moreover, long-term outcome of 1 year postoperation judged by Glasgow Outcome Scale (GOS), Barthel Index (BI), modified Rankin Scale (mRS) and case fatality(CF). Results MG patients showed obvious amelioration in GCS score compared with that of CG. The total incidence of PC in MG decreased obviously compared with that of CG. The incidences of rebleeding in MG and CG were 10.0% and 15.4% respectively. There was no obvious difference between CFs of MG and CG. For three parameters representing long-term outcome, the GOS, BI and mRS in MG were ameliorated significantly than that of CG. Conclusion These data suggested that the advantage of MISPT was displayed in minute trauma and safety, and seemed to be feasible and to had a trend towards improved long-term outcome. Trial Registration The Australian New Zealand Clinical Trials Registry (ANZCTR), the registration number:ACTRN12610000945022. PMID:21699716
Marciscano, Ariel E; Huang, Judy; Tamargo, Rafael J; Hu, Chen; Khattab, Mohamed H; Aggarwal, Sameer; Lim, Michael; Redmond, Kristin J; Rigamonti, Daniele; Kleinberg, Lawrence R
2017-07-01
There is no consensus regarding the optimal management of inoperable high-grade arteriovenous malformations (AVMs). This long-term study of 42 patients with high-grade AVMs reports obliteration and adverse event (AE) rates using planned multistage repeat stereotactic radiosurgery (SRS). To evaluate the efficacy and safety of multistage SRS with treatment of the entire AVM nidus at each treatment session to achieve complete obliteration of high-grade AVMs. Patients with high-grade Spetzler-Martin (S-M) III-V AVMs treated with at least 2 multistage SRS treatments from 1989 to 2013. Clinical outcomes of obliteration rate, minor/major AEs, and treatment characteristics were collected. Forty-two patients met inclusion criteria (n = 26, S-M III; n = 13, S-M IV; n = 3, S-M V) with a median follow-up was 9.5 yr after first SRS. Median number of SRS treatment stages was 2, and median interval between stages was 3.5 yr. Twenty-two patients underwent pre-SRS embolization. Complete AVM obliteration rate was 38%, and the median time to obliteration was 9.7 yr. On multivariate analysis, higher S-M grade was significantly associated ( P = .04) failure to achieve obliteration. Twenty-seven post-SRS AEs were observed, and the post-SRS intracranial hemorrhage rate was 0.027 events per patient year. Treatment of high-grade AVMs with multistage SRS achieves AVM obliteration in a meaningful proportion of patients with acceptable AE rates. Lower obliteration rates were associated with higher S-M grade and pre-SRS embolization. This approach should be considered with caution, as partial obliteration does not protect from hemorrhage. Copyright © 2017 by the Congress of Neurological Surgeons
Failure Mode and Effect Analysis for Delivery of Lung Stereotactic Body Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perks, Julian R., E-mail: julian.perks@ucdmc.ucdavis.edu; Stanic, Sinisa; Stern, Robin L.
2012-07-15
Purpose: To improve the quality and safety of our practice of stereotactic body radiation therapy (SBRT), we analyzed the process following the failure mode and effects analysis (FMEA) method. Methods: The FMEA was performed by a multidisciplinary team. For each step in the SBRT delivery process, a potential failure occurrence was derived and three factors were assessed: the probability of each occurrence, the severity if the event occurs, and the probability of detection by the treatment team. A rank of 1 to 10 was assigned to each factor, and then the multiplied ranks yielded the relative risks (risk priority numbers).more » The failure modes with the highest risk priority numbers were then considered to implement process improvement measures. Results: A total of 28 occurrences were derived, of which nine events scored with significantly high risk priority numbers. The risk priority numbers of the highest ranked events ranged from 20 to 80. These included transcription errors of the stereotactic coordinates and machine failures. Conclusion: Several areas of our SBRT delivery were reconsidered in terms of process improvement, and safety measures, including treatment checklists and a surgical time-out, were added for our practice of gantry-based image-guided SBRT. This study serves as a guide for other users of SBRT to perform FMEA of their own practice.« less
NASA Astrophysics Data System (ADS)
Barón-Aznar, C.; Moreno-Jiménez, S.; Celis, M. A.; Lárraga-Gutiérrez, J. M.; Ballesteros-Zebadúa, P.
2008-08-01
Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScansoftware, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed.
Liu, Liang-ming; Hu, De-yao; Liu, Jian-cang; Li, Ping; Liu, Hou-dong; Xiao, Nan; Zhou, Xue-wu; Tian, Kun-lun; Huo, Xiao-ping; Shi, Quan-gui; He, Yan-mei; Yin, Zuo-ming
2003-05-01
To study the effects of different volumes of fluid resuscitation on hemorrhagic shock with pulmonary edema at high altitude in the unacclimated rat. One hundred and twenty-six SD rats transported to Lasa, Tibet, 3 760 meters above the sea level, were anesthetized one week later with sodium pentobarbital (30 mg/kg, intraperitoneal). Hemorrhagic shock with pulmonary edema model was induced by hemorrhage (50 mm Hg for 1 hour, 1 mmHg=0.133 kPa) plus intravenous injection of oleic acid (50 microl/kg). Experiments were then conducted in two parts. Sixty-three rats in part I were equally divided into nine groups (n=7): normal control, hemorrhagic shock control, hemorrhagic shock with pulmonary edema (HSPE) without fluid infusion, HSPE plus infusing lactated Ringer's solution (LR) with 0.5-, 1-, 1.5-, 2- or 3- fold volume shed blood, and 1 volume of LR plus mannitol (10 ml/kg). Hemodynamic parameters including mean arterial blood pressure (MAP), left intraventricular systolic pressure (LVSP) and the maximal change rate of intraventricular pressure rise or decline (+/- dp/dt max) were observed at 15, 30, 60 and 120 minutes after infusion, blood gases were measured at 30 and 120 minutes after infusion and the water content of lung and brain was determined at 120 minutes after infusion. In part II, additional 63 rats were used to observe the effect of different volumes of fluid resuscitation on survival time of HSPE rats. 0.5 volume of LR infusion significantly improved MAP, LVSP and +/- dp/dt max, prolonged the survival time of HSPE animals (all P<0.01), while it did not increase the water content of lung and brain and had no marked influence on blood gases. One volume of LR infusion slightly improved hemodynamic parameters, prolonged the survival time and increased the water content of lung. More than 1 volume of LR infusion including 1.5-, 2- and 3- fold volume LR deteriorated the hemodynamic parameters and decreased the survival time of shocked animal, meanwhile they apparently increased the water content of lung. One volume of LR plus mannitol (10 ml/kg) infusion did not improve the hemodynamic parameters and blood gases; also it did not decrease the water content of lung. The tolerance to fluid infusion for the unacclimated animal subjected to hemorrhagic shock with pulmonary edema at high altitude is significantly decreased. 0.5-1 volume of LR infusion appears to be beneficial effect on resuscitation at high altitude, while over 1 volume of LR infusion would aggravate pulmonary edema and exacerbate fluid resuscitation effect.
[Radiofrequency ablation of hepatocellular carcinoma].
Widmann, Gerlig; Schullian, Peter; Bale, Reto
2013-03-01
Percutaneous radiofrequency ablation (RFA) is well established in the treatment of hepatocellular carcinoma (HCC). Due to its curative potential, it is the method of choice for non resectable BCLC (Barcelona Liver Clinic) 0 and A. RFA challenges surgical resection for small HCC and is the method of choice in bridging for transplantation and recurrence after resection or transplantation. The technical feasibility of RFA depends on the size and location of the HCC and the availability of ablation techniques (one needle techniques, multi-needle techniques). More recently, stereotactic multi-needle techniques with 3D trajectory planning and guided needle placement substantially improve the spectrum of treatable lesions including large volume tumors. Treatment success depends on the realization of ablations with large intentional margins of tumor free tissue (A0 ablation in analogy to R0 resection), which has to be documented by fusion of post- with pre-ablation images, and confirmed during follow-up imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barish, R.J.; Barish, S.V.
1988-06-01
For many years, the irradiation of small volumes of tissue in the brain to necrotizing doses has been investigated as a non-invasive alternative to neurosurgery. We propose a new system in which a precisely machined helmet serves as a multi-port focussed X-ray collimator when it is itself irradiated by a conventional medical linear accelerator run in the electron mode. When the collimator is attached to a stereotactic frame, the geometric accuracy of delivering small radiation fields to the brain is limited primarily by the accuracy of the stereotactic localization, and is relatively independent of the positional stability of the accelerator.more » Field sizes as small as two millimeters are readily achievable. The problem of low dose rate associated with these small fields is overcome by the use of high electron beam currents.« less
Biophysical characterization of a relativistic proton beam for image-guided radiosurgery
Yu, Zhan; Vanstalle, Marie; La Tessa, Chiara; Jiang, Guo-Liang; Durante, Marco
2012-01-01
We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1–10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery. PMID:22843629
Lee, Cheng-Chia; Chen, Ching-Jen; Ball, Benjamin; Schlesinger, David; Xu, Zhiyuan; Yen, Chun-Po; Sheehan, Jason
2015-07-01
Onyx, an ethylene-vinyl alcohol copolymer mixed in a dimethyl sulfoxide solvent, is currently one of the most widely used liquid materials for embolization of intracranial arteriovenous malformations (AVMs). The goal of this study was to define the risks and benefits of stereotactic radiosurgery (SRS) for patients who have previously undergone partial AVM embolization with Onyx. Among a consecutive series of 199 patients who underwent SRS between January 2007 and December 2012 at the University of Virginia, 25 patients had Onyx embolization prior to SRS (the embolization group). To analyze the obliteration rates and complications, 50 patients who underwent SRS without prior embolization (the no-embolization group) were matched by propensity score method. The matched variables included age, sex, nidus volume before SRS, margin dose, Spetzler-Martin grade, Virginia Radiosurgery AVM Scale score, and median imaging follow-up period. After Onyx embolization, 18 AVMs were reduced in size. Total obliteration was achieved in 6 cases (24%) at a median of 27.5 months after SRS. In the no-embolization group, total obliteration was achieved in 20 patients (40%) at a median of 22.4 months after SRS. Kaplan-Meier analysis demonstrated obliteration rates of 17.7% and 34.1% in the embolization group at 2 and 4 years, respectively. In the no-embolization group, the corresponding obliteration rates were 27.0% and 55.9%. The between-groups difference in obliteration rates after SRS did not achieve statistical significance. The difference in complications, including adverse radiation effects, hemorrhage episodes, seizure control, and patient mortality also did not reach statistical significance. Onyx embolization can effectively reduce the size of many AVMs. This case-control study did not show any statistically significant difference in the rates of embolization or complications after SRS in patients who had previously undergone Onyx embolization and those who had not.
Nakano, Takafumi; Irie, Keiichi; Hayakawa, Kazuhide; Sano, Kazunori; Nakamura, Yoshihiko; Tanaka, Masayoshi; Yamashita, Yuta; Satho, Tomomitsu; Fujioka, Masayuki; Muroi, Carl; Matsuo, Koichi; Ishikura, Hiroyasu; Futagami, Kojiro; Mishima, Kenichi
2015-10-22
Tissue plasminogen activator (tPA) is the only approved therapy for acute ischemic stroke. However, delayed tPA treatment increases the risk of cerebral hemorrhage and can result in exacerbation of nerve injury. ADAMTS13, a von Willebrand factor (VWF) cleaving protease, has a protective effect against ischemic brain injury and may reduce bleeding risk by cleaving VWF. We examined whether ADAMTS13 has a longer therapeutic time window in ischemic stroke than tPA in mice subjected to middle cerebral artery occlusion (MCAO). ADAMTS13 (0.1mg/kg) or tPA (10mg/kg) was administered i.v., immediately after reperfusion of after 2-h or 4-h MCAO for comparison of the therapeutic time windows in ischemic stroke. Infarct volume, hemorrhagic volume, plasma high-mobility group box1 (HMGB1) levels and cerebral blood flow were measured 24h after MCAO. Both ADAMTS13 and tPA improved the infarct volume without hemorrhagic complications in 2-h MCAO mice. On the other hand, ADAMTS13 reduced the infarct volume and plasma HMGB1 levels, and improved cerebral blood flow without hemorrhagic complications in 4-h MCAO mice, but tPA was not effective and these animals showed massive intracerebral hemorrhage. These results indicated that ADAMTS13 has a longer therapeutic time window in ischemic stroke than tPA, and ADAMTS13 may be useful as a new therapeutic agent for ischemic stroke. Copyright © 2015 Elsevier B.V. All rights reserved.
The hypothalamus at the crossroads of psychopathology and neurosurgery.
Barbosa, Daniel A N; de Oliveira-Souza, Ricardo; Monte Santo, Felipe; de Oliveira Faria, Ana Carolina; Gorgulho, Alessandra A; De Salles, Antonio A F
2017-09-01
The neurosurgical endeavor to treat psychiatric patients may have been part of human history since its beginning. The modern era of psychosurgery can be traced to the heroic attempts of Gottlieb Burckhardt and Egas Moniz to alleviate mental symptoms through the ablation of restricted areas of the frontal lobes in patients with disabling psychiatric illnesses. Thanks to the adaptation of the stereotactic frame to human patients, the ablation of large volumes of brain tissue has been practically abandoned in favor of controlled interventions with discrete targets. Consonant with the role of the hypothalamus in the mediation of the most fundamental approach-avoidance behaviors, some hypothalamic nuclei and regions, in particular, have been selected as targets for the treatment of aggressiveness (posterior hypothalamus), pathological obesity (lateral or ventromedial nuclei), sexual deviations (ventromedial nucleus), and drug dependence (ventromedial nucleus). Some recent improvements in outcomes may have been due to the use of stereotactically guided deep brain stimulation and the change of therapeutic focus from categorical diagnoses (such as schizophrenia) to dimensional symptoms (such as aggressiveness), which are nonspecific in terms of formal diagnosis. However, agreement has never been reached on 2 related issues: 1) the choice of target, based on individual diagnoses; and 2) reliable prediction of outcomes related to individual targets. Despite the lingering controversies on such critical aspects, the experience of the past decades should pave the way for advances in the field. The current failure of pharmacological treatments in a considerable proportion of patients with chronic disabling mental disorders is reminiscent of the state of affairs that prevailed in the years before the early psychosurgical attempts. This article reviews the functional organization of the hypothalamus, the effects of ablation and stimulation of discrete hypothalamic regions, and the stereotactic targets that have most often been used in the treatment of psychopathological and behavioral symptoms; finally, the implications of current and past experience are presented from the perspective of how this fund of knowledge may usefully contribute to the future of hypothalamic psychosurgery.
Stereotactic Image-Guided Navigation During Breast Reconstruction in Patients With Breast Cancer
2017-04-12
Ductal Breast Carcinoma in Situ; Lobular Breast Carcinoma in Situ; Recurrent Breast Cancer; Stage IA Breast Cancer; Stage IB Breast Cancer; Stage II Breast Cancer; Stage IIIA Breast Cancer; Stage IIIB Breast Cancer; Stage IIIC Breast Cancer; Stage IV Breast Cancer
Pappas, Eleftherios P; Alshanqity, Mukhtar; Moutsatsos, Argyris; Lababidi, Hani; Alsafi, Khalid; Georgiou, Konstantinos; Karaiskos, Pantelis; Georgiou, Evangelos
2017-12-01
In view of their superior soft tissue contrast compared to computed tomography, magnetic resonance images are commonly involved in stereotactic radiosurgery/radiotherapy applications for target delineation purposes. It is known, however, that magnetic resonance images are geometrically distorted, thus deteriorating dose delivery accuracy. The present work focuses on the assessment of geometric distortion inherent in magnetic resonance images used in stereotactic radiosurgery/radiotherapy treatment planning and attempts to quantitively evaluate the consequent impact on dose delivery. The geometric distortions for 3 clinical magnetic resonance protocols (at both 1.5 and 3.0 T) used for stereotactic radiosurgery/radiotherapy treatment planning were evaluated using a recently proposed phantom and methodology. Areas of increased distortion were identified at the edges of the imaged volume which was comparable to a brain scan. Although mean absolute distortion did not exceed 0.5 mm on any spatial axis, maximum detected control point disposition reached 2 mm. In an effort to establish what could be considered as acceptable geometric uncertainty, highly conformal plans were utilized to irradiate targets of different diameters (5-50 mm). The targets were mispositioned by 0.5 up to 3 mm, and dose-volume histograms and plan quality indices clinically used for plan evaluation and acceptance were derived and used to investigate the effect of geometrical uncertainty (distortion) on dose delivery accuracy and plan quality. The latter was found to be strongly dependent on target size. For targets less than 20 mm in diameter, a spatial disposition of the order of 1 mm could significantly affect (>5%) plan acceptance/quality indices. For targets with diameter greater than 2 cm, the corresponding disposition was found greater than 1.5 mm. Overall results of this work suggest that efficacy of stereotactic radiosurgery/radiotherapy applications could be compromised in case of very small targets lying distant from the scanner's isocenter (eg, the periphery of the brain).
Marsh, E B; Llinas, R H; Hillis, A E; Gottesman, R F
2013-06-01
Intracerebral hemorrhage (ICH) can occur in patients following acute ischaemic stroke in the form of hemorrhagic transformation, and results in significant long-term morbidity and mortality. Anticoagulation theoretically increases risk. We evaluated stroke patients with an indication for anticoagulation to determine the factors associated with hemorrhagic transformation. Three-hundred and forty-five patients with ICD-9 codes indicating: (i) acute ischaemic stroke; and (ii) an indication for anticoagulation were screened. One-hundred and twenty-three met inclusion criteria. Data were collected retrospectively. Neuroimaging was reviewed for infarct volume and evidence of ICH. Hemorrhages were classified as: hemorrhagic conversion (petechiae) versus intracerebral hematoma (a space occupying lesion); symptomatic versus asymptomatic. Using multivariable logistic regression, we determined the hypothesized factors associated with intracerebral bleeding. Age [odds ratio (OR) = 1.50 per 10-year increment, 95% confidence interval (CI) 1.07-2.08], infarct volume (OR = 1.10 per 10 ccs, 95% CI 1.06-1.18) and worsening category of renal impairment by estimated glomerular filtration rate (eGFR; OR = 1.95, 95% CI 1.04-3.66) were predictors of hemorrhagic transformation. Ninety- nine out of 123 patients were anticoagulated. Hemorrhage rates of patients on and off anticoagulation did not differ (25.3% vs. 20.8%; P = 0.79); however, all intracerebral hematomas (n = 7) and symptomatic bleeds (n = 8) occurred in the anticoagulated group. The risk of hemorrhagic transformation in patients with acute ischaemic stroke and an indication for anticoagulation is multifactorial, and most closely associated with an individual's age, infarct volume and eGFR. © 2013 The Author(s) European Journal of Neurology © 2013 EFNS.
Kim, Minsoo; Jung, Na Young; Park, Chang Kyu; Chang, Won Seok; Jung, Hyun Ho; Chang, Jin Woo
2018-06-01
Stereotactic procedures are image guided, often using magnetic resonance (MR) images limited by image distortion, which may influence targets for stereotactic procedures. The aim of this work was to assess methods of identifying target coordinates for stereotactic procedures with MR in multiple phase-encoding directions. In 30 patients undergoing deep brain stimulation, we acquired 5 image sets: stereotactic brain computed tomography (CT), T2-weighted images (T2WI), and T1WI in both right-to-left (RL) and anterior-to-posterior (AP) phase-encoding directions. Using CT coordinates as a reference, we analyzed anterior commissure and posterior commissure coordinates to identify any distortion relating to phase-encoding direction. Compared with CT coordinates, RL-directed images had more positive x-axis values (0.51 mm in T1WI, 0.58 mm in T2WI). AP-directed images had more negative y-axis values (0.44 mm in T1WI, 0.59 mm in T2WI). We adopted 2 methods to predict CT coordinates with MR image sets: parallel translation and selective choice of axes according to phase-encoding direction. Both were equally effective at predicting CT coordinates using only MR; however, the latter may be easier to use in clinical settings. Acquiring MR in multiple phase-encoding directions and selecting axes according to the phase-encoding direction allows identification of more accurate coordinates for stereotactic procedures. © 2018 S. Karger AG, Basel.
Pediatric neuroanesthesia. Arteriovenous malformations.
Newfield, P; Hamid, R K
2001-06-01
Intracranial arteriovenous malformations can occur singly, multiply, and in conjunction with aneurysms and denovo, family, or in conjunction with connective-tissue disorders. Intracranial hemorrhage is the most common presentation, occurring in 20% to 50% of cases. In children, seizures are the second most common presentation occurring in 15% to 20% of cases. The modalities available treatment of arteriovenous malformations are microsurgery, embolization, and stereotactic radiosurgery with heavy particles, alpha knife, or linear accelerator. Induction, maintenance, and emergence from anesthesia are designed to prevent rupture of arteriovenous malformation and aneurysm and to improve intracranial compliance in the presence of an intracranial hematoma, during both diagnostic (CT, MR scanning) and therapeutic procedures.
Design and simulation of an articulated surgical arm for guiding stereotactic neurosurgery
NASA Astrophysics Data System (ADS)
Kadi, A. Majeed; Zamorano, Lucia J.; Frazer, Matthew P.; Lu, Yi
1992-03-01
In stereotactic surgery, the need exists for means of relating intraoperatively the position and orientation of the surgical instrument used by the neurosurgeon to a known frame of reference. An articulated arm is proposed which would provide the neurosurgeon with on-line information for position, and orientation of the surgical tools being moved by the neurosurgeon. The articulated arm has six degrees of freedom, with five revolute and one prismatic joints. The design features include no obstruction to the field of view, lightweight, good balance against gravity, an accuracy of 1 mm spherical error probability (SEP), and a solvable kinematic structure making it capable of fitting the operating room environment. The arm can be mounted on either the surgical table or the stereotactic frame. A graphical simulation of the arm was created using the IGRIP simulation package created by Deneb Robotics. The simulation demonstrates the use of the arm, mounted on several positions of the ring reaching various target points within the cranium.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riegel, Adam C. B.A.; Chang, Joe Y.; Vedam, Sastry S.
2009-02-01
Purpose: To determine whether cine computed tomography (CT) can serve as an alternative to four-dimensional (4D)-CT by providing tumor motion information and producing equivalent target volumes when used to contour in radiotherapy planning without a respiratory surrogate. Methods and Materials: Cine CT images from a commercial CT scanner were used to form maximum intensity projection and respiratory-averaged CT image sets. These image sets then were used together to define the targets for radiotherapy. Phantoms oscillating under irregular motion were used to assess the differences between contouring using cine CT and 4D-CT. We also retrospectively reviewed the image sets for 26more » patients (27 lesions) at our institution who had undergone stereotactic radiotherapy for Stage I non-small-cell lung cancer. The patients were included if the tumor motion was >1 cm. The lesions were first contoured using maximum intensity projection and respiratory-averaged CT image sets processed from cine CT and then with 4D-CT maximum intensity projection and 10-phase image sets. The mean ratios of the volume magnitude were compared with intraobserver variation, the mean centroid shifts were calculated, and the volume overlap was assessed with the normalized Dice similarity coefficient index. Results: The phantom studies demonstrated that cine CT captured a greater extent of irregular tumor motion than did 4D-CT, producing a larger tumor volume. The patient studies demonstrated that the gross tumor defined using cine CT imaging was similar to, or slightly larger than, that defined using 4D-CT. Conclusion: The results of our study have shown that cine CT is a promising alternative to 4D-CT for stereotactic radiotherapy planning.« less
Risk of hemorrhage in ischemic stroke and its relationship with cerebral microbleeds.
Ozbek, Damla; Ozturk Tan, Ozlem; Ekinci, Gazanfer; Midi, Ipek
2018-05-01
Stroke is an important public health problem in most countries. Therefore, the treatment of stroke and its complications is important. Intracerebral hemorrhage is one of the complications of ischemic stroke. This study aimed to investigate the risk of hemorrhage in patients with acute ischemic stroke and prospectively study its relationship with cerebral microbleeds (MBs) using susceptibility-weighted imaging (SWI) that is a magnetic resonance imaging (MRI) sequence. Patients with acute ischemic stroke were included. Those who underwent treatment with tissue plasminogen activator were excluded. The patients were analyzed according to their risk factors for stroke and their relationship with intracerebral hemorrhage. A total of 148 patients were included. Of these, 41 (28%) had hemorrhages in the ischemic area. The mean waist circumferences, left atrium diameter, and heart rate in these patients were higher than those in patients without hemorrhage. MBs were detected in 66 patients (44.6%) using SWI, and there was no significant relationship with the presence of hemorrhage. Intracerebral hemorrhages were significantly associated with the volume and localization of infarcts. Intracerebral hemorrhage in patients with acute ischemic stroke within the first 7 days after stroke onset was related to their waist circumference as well as the volume and localization of the infarct. However, there was no relationship found between the risk of hemorrhage and MBs using SWI. Copyright © 2018 Elsevier B.V. All rights reserved.
Lüders, Jürgen C; Steinmetz, Michael P; Mayberg, Marc R
2005-01-01
Infectious (mycotic) aneurysms that do not resolve with medical treatment require surgical obliteration, usually requiring sacrifice of the parent artery. In addition, patients with mycotic aneurysms frequently need subsequent cardiac valve repair, which often necessitates anticoagulation. Three cases of awake craniotomy for microsurgical clipping of mycotic aneurysms are presented. Awake minimally invasive craniotomy using frameless stereotactic guidance on the basis of computed tomographic angiography enables temporary occlusion of the parent artery with neurological assessment before obliteration of the aneurysm. A 56-year-old woman presented with progressively worsening mitral valve disease and a history of subacute bacterial endocarditis and subarachnoid hemorrhage 30 years previously. A cerebral angiogram revealed a 4-mm left middle cerebral artery (MCA) angular branch aneurysm, which required obliteration before mitral valve replacement. The second patient, a 64-year-old woman with a history of rheumatic fever, had an 8-mm right distal MCA aneurysm diagnosed in the setting of pulmonary abscess and worsening cardiac function as a result of mitral valve disease. The third patient, a 57-year-old man with a history of fevers, night sweats, and progressive mitral valve disease, had an enlarging left MCA angular branch aneurysm despite the administration of antibiotics. Because of their location on distal MCA branches, none of the aneurysms were amenable to preoperative test balloon occlusion. After undergoing stereotactic computed tomographic angiography with fiducial markers, the patients underwent a minimally invasive awake craniotomy with frameless stereotactic navigation. In all cases, the results of the neurological examination were unchanged during temporary parent artery occlusion and the aneurysms were successfully obliterated. Awake minimally invasive craniotomy for an infectious aneurysm located in eloquent brain enables awake testing before permanent clipping or vessel sacrifice. Combining frameless stereotactic navigation with computed tomographic angiography allowed us to perform the operation quickly through a small craniotomy with minimal exploration.
Richmond, N D; Pilling, K E; Peedell, C; Shakespeare, D; Walker, C P
2012-01-01
Stereotactic body radiotherapy for early stage non-small cell lung cancer is an emerging treatment option in the UK. Since relatively few high-dose ablative fractions are delivered to a small target volume, the consequences of a geometric miss are potentially severe. This paper presents the results of treatment delivery set-up data collected using Elekta Synergy (Elekta, Crawley, UK) cone-beam CT imaging for 17 patients immobilised using the Bodyfix system (Medical Intelligence, Schwabmuenchen, Germany). Images were acquired on the linear accelerator at initial patient treatment set-up, following any position correction adjustments, and post-treatment. These were matched to the localisation CT scan using the Elekta XVI software. In total, 71 fractions were analysed for patient set-up errors. The mean vector error at initial set-up was calculated as 5.3±2.7 mm, which was significantly reduced to 1.4±0.7 mm following image guided correction. Post-treatment the corresponding value was 2.1±1.2 mm. The use of the Bodyfix abdominal compression plate on 5 patients to reduce the range of tumour excursion during respiration produced mean longitudinal set-up corrections of −4.4±4.5 mm compared with −0.7±2.6 mm without compression for the remaining 12 patients. The use of abdominal compression led to a greater variation in set-up errors and a shift in the mean value. PMID:22665927
Larson, Paul S; Willie, Jon T; Vadivelu, Sudhakar; Azmi-Ghadimi, Hooman; Nichols, Amy; Fauerbach, Loretta Litz; Johnson, Helen Boehm; Graham, Denise
2017-07-01
The development of navigation technology facilitating MRI-guided stereotactic neurosurgery has enabled neurosurgeons to perform a variety of procedures ranging from deep brain stimulation to laser ablation entirely within an intraoperative or diagnostic MRI suite while having real-time visualization of brain anatomy. Prior to this technology, some of these procedures required multisite workflow patterns that presented significant risk to the patient during transport. For those facilities with access to this technology, safe practice guidelines exist only for procedures performed within an intraoperative MRI. There are currently no safe practice guidelines or parameters available for facilities looking to integrate this technology into practice in conventional MRI suites. Performing neurosurgical procedures in a diagnostic MRI suite does require precautionary measures. The relative novelty of technology and workflows for direct MRI-guided procedures requires consideration of safe practice recommendations, including those pertaining to infection control and magnet safety issues. This article proposes a framework of safe practice recommendations designed for assessing readiness and optimization of MRI-guided neurosurgical interventions in the diagnostic MRI suite in an effort to mitigate patient risk. The framework is based on existing clinical evidence, recommendations, and guidelines related to infection control and prevention, health care-associated infections, and magnet safety, as well as the clinical and practical experience of neurosurgeons utilizing this technology. © 2017 American Society for Healthcare Risk Management of the American Hospital Association.
MO-B-201-00: Motion Management in Current Stereotactic Body Radiation Therapy (SBRT) Practice
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanicsmore » of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.« less
Charbonneau, Hélène; Buléon, Marie; Minville, Vincent; Faguer, Stanislas; Girolami, Jean-Pierre; Bascands, Jean-Loup; Tack, Ivan; Mayeur, Nicolas
2016-09-01
Angiotensin-converting enzyme inhibitors are associated with deleterious hypotension during anesthesia and shock. Because the pharmacologic effects of angiotensin-converting enzyme inhibitors are partly mediated by increased bradykinin B2 receptor activation, this study aimed to determine the impact of acute B2 receptor blockade during hemorrhagic shock in angiotensin-converting enzyme inhibitor-treated mice. In vivo study. University research unit. C57/Bl6 mice. The hemodynamic effect of B2 receptor blockade using icatibant (B2 receptor antagonist) was studied using a pressure-targeted hemorrhagic shock and a volume-targeted hemorrhagic shock. Animals were anesthetized with ketamine and xylazine (250 mg/kg and 10 mg/kg, respectively), intubated using intratracheal cannula, and ventilated (9 mL/kg, 150 min). Five groups were studied: 1) sham-operated animals, 2) control shocked mice, 3) shocked mice treated with ramipril for 7 days (angiotensin-converting enzyme inhibitors) before hemorrhagic shock, 4) shocked mice treated with angiotensin-converting enzyme inhibitors and a single bolus of icatibant (HOE-140) immediately before anesthesia (angiotensin-converting enzyme inhibitors + icatibant), and 5) shocked mice treated with a single bolus of icatibant. One hour after volume-targeted hemorrhagic shock, blood lactate was measured to evaluate organ failure. During pressure-targeted hemorrhagic shock, the mean blood volume withdrawn was significantly lower in the angiotensin-converting enzyme inhibitor group than in the other groups (p < 0.001). During volume-targeted hemorrhagic shock, icatibant prevented blood pressure lowering in the angiotensin-converting enzyme inhibitor group (p < 0.001). Blood lactate was significantly higher in the angiotensin-converting enzyme inhibitor group than in the other groups, particularly the HOE groups. During hemorrhagic shock, acute B2 receptor blockade significantly attenuates the deleterious hemodynamic effect of angiotensin-converting enzyme inhibitor treatment in mice. This beneficial effect of B2 receptor blockade is rapidly reached and sustained with a single bolus of icatibant. This benefit could be of interest in angiotensin-converting enzyme inhibitor-treated patients during both emergency anesthesia and resuscitation.
László, Zoltán; Boronkai, Árpád; Lõcsei, Zoltán; Kalincsák, Judit; Szappanos, Szabolcs; Farkas, Róbert; Al Farhat, Yousuf; Sebestyén, Zsolt; Sebestyén, Klára; Kovács, Péter; Csapó, László; Mangel, László
2015-06-01
With the development of radiation therapy technology, the utilization of more accurate patient fixation, inclusion of PET/CT image fusion into treatment planning, 3D image-guided radiotherapy, and intensity-modulated dynamic arc irradiation, the application of hypofractionated stereotactic radiotherapy can be extended to specified extracranial target volumes, and so even to the treatment of various metastases. Between October 2012 and August 2014 in our institute we performed extracranial, hypofractionated, image-többguided radiotherapy with RapidArc system for six cases, and 3D conformal multifield technique for one patient with Novalis TX system in case of different few-numbered and slow-growing metastases. For the precise definition of the target volumes we employed PET/CT during the treatment planning procedure. Octreotid scan was applied in one carcinoid tumour patient. Considering the localisation of the metastases and the predictable motion of the organs, we applied 5 to 20 mm safety margin during the contouring procedure. The average treatment volume was 312 cm3. With 2.5-3 Gy fraction doses we delivered 39-45 Gy total dose, and the treatment duration was 2.5 to 3 weeks. The image guidance was carried out via ExacTrac, and kV-Cone Beam CT equipment based on an online protocol, therefore localisation differences were corrected before every single treatment. The patients tolerated the treatments well without major (Gr>2) side effects. Total or near total regression of the metastases was observed at subsequent control examinations in all cases (the median follow-up time was 5 months). According to our first experience, extracranial, imageguided hypofractionated radiotherapy is well-tolerated by patients and can be effectively applied in the treatment of slow-growing and few-numbered metastases.
Automatic pose correction for image-guided nonhuman primate brain surgery planning
NASA Astrophysics Data System (ADS)
Ghafurian, Soheil; Chen, Antong; Hines, Catherine; Dogdas, Belma; Bone, Ashleigh; Lodge, Kenneth; O'Malley, Stacey; Winkelmann, Christopher T.; Bagchi, Ansuman; Lubbers, Laura S.; Uslaner, Jason M.; Johnson, Colena; Renger, John; Zariwala, Hatim A.
2016-03-01
Intracranial delivery of recombinant DNA and neurochemical analysis in nonhuman primate (NHP) requires precise targeting of various brain structures via imaging derived coordinates in stereotactic surgeries. To attain targeting precision, the surgical planning needs to be done on preoperative three dimensional (3D) CT and/or MR images, in which the animals head is fixed in a pose identical to the pose during the stereotactic surgery. The matching of the image to the pose in the stereotactic frame can be done manually by detecting key anatomical landmarks on the 3D MR and CT images such as ear canal and ear bar zero position. This is not only time intensive but also prone to error due to the varying initial poses in the images which affects both the landmark detection and rotation estimation. We have introduced a fast, reproducible, and semi-automatic method to detect the stereotactic coordinate system in the image and correct the pose. The method begins with a rigid registration of the subject images to an atlas and proceeds to detect the anatomical landmarks through a sequence of optimization, deformable and multimodal registration algorithms. The results showed similar precision (maximum difference of 1.71 in average in-plane rotation) to a manual pose correction.
Stereotactic radiosurgery with the linear accelerator: treatment of arteriovenous malformations.
Betti, O O; Munari, C; Rosler, R
1989-03-01
An original stereotactic radiosurgical approach coupling a) Talairach's stereotactic methodology, b) a specially devised mechanical system, and c) a linear accelerator is detailed. The authors present their preliminary results on 66 patients with nonsurgical intracranial arteriovenous malformations. The doses delivered for treatment varied from 20 to 70 Gy. Doses of no more than 40 Gy were used in 80% of patients. An angiographic study was performed when the computed tomographic scan controls showed relevant modifications of the lesion volume. Total obliteration was obtained in 27 of the 41 patients (65.8%) who were followed up for at least 24 months. The percentage of the cured patients is significantly higher when a) the entire malformation is included in the 75% isodose (96%) and b) the maximum diameter of the lesion is less than 12 mm (81%). Two patients died of rebleeding at 18 and 29 months after treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baron-Aznar, C.; Moreno-Jimenez, S.; Celis, M. A.
2008-08-11
Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScan(c) software, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Joe Y., E-mail: jychang@mdanderson.org; Li, Qiao-Qiao; Xu, Qing-Yong
2014-04-01
Purpose: We extended our previous experience with stereotactic ablative radiation therapy (SABR; 50 Gy in 4 fractions) for centrally located non-small cell lung cancer (NSCLC); explored the use of 70 Gy in 10 fractions for cases in which dose-volume constraints could not be met with the previous regimen; and suggested modified dose-volume constraints. Methods and Materials: Four-dimensional computed tomography (4DCT)-based volumetric image-guided SABR was used for 100 patients with biopsy-proven, central T1-T2N0M0 (n=81) or isolated parenchymal recurrence of NSCLC (n=19). All disease was staged with positron emission tomography/CT; all tumors were within 2 cm of the bronchial tree, trachea, major vessels, esophagus, heart,more » pericardium, brachial plexus, or vertebral body. Endpoints were toxicity, overall survival (OS), local and regional control, and distant metastasis. Results: At a median follow-up time of 30.6 months, median OS time was 55.6 months, and the 3-year OS rate was 70.5%. Three-year cumulative actuarial local, regional, and distant control rates were 96.5%, 87.9%, and 77.2%, respectively. The most common toxicities were chest-wall pain (18% grade 1, 13% grade 2) and radiation pneumonitis (11% grade 2 and 1% grade 3). No patient experienced grade 4 or 5 toxicity. Among the 82 patients receiving 50 Gy in 4 fractions, multivariate analyses showed mean total lung dose >6 Gy, V{sub 20} >12%, or ipsilateral lung V{sub 30} >15% to independently predict radiation pneumonitis; and 3 of 9 patients with brachial plexus D{sub max} >35 Gy experienced brachial neuropathy versus none of 73 patients with brachial D{sub max} <35 Gy (P=.001). Other toxicities were analyzed and new dose-volume constraints are proposed. Conclusions: SABR for centrally located lesions produces clinical outcomes similar to those for peripheral lesions when normal tissue constraints are respected.« less
Technical Note: Dose gradients and prescription isodose in orthovoltage stereotactic radiosurgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fagerstrom, Jessica M., E-mail: fagerstrom@wisc.edu; Bender, Edward T.; Culberson, Wesley S.
Purpose: The purpose of this work is to examine the trade-off between prescription isodose and dose gradients in orthovoltage stereotactic radiosurgery. Methods: Point energy deposition kernels (EDKs) describing photon and electron transport were calculated using Monte Carlo methods. EDKs were generated from 10 to 250 keV, in 10 keV increments. The EDKs were converted to pencil beam kernels and used to calculate dose profiles through isocenter from a 4π isotropic delivery from all angles of circularly collimated beams. Monoenergetic beams and an orthovoltage polyenergetic spectrum were analyzed. The dose gradient index (DGI) is the ratio of the 50% prescription isodosemore » volume to the 100% prescription isodose volume and represents a metric by which dose gradients in stereotactic radiosurgery (SRS) may be evaluated. Results: Using the 4π dose profiles calculated using pencil beam kernels, the relationship between DGI and prescription isodose was examined for circular cones ranging from 4 to 18 mm in diameter and monoenergetic photon beams with energies ranging from 20 to 250 keV. Values were found to exist for prescription isodose that optimize DGI. Conclusions: The relationship between DGI and prescription isodose was found to be dependent on both field size and energy. Examining this trade-off is an important consideration for designing optimal SRS systems.« less
Stereotactic multibeam radiation therapy system in a PACS environment
NASA Astrophysics Data System (ADS)
Fresne, Francoise; Le Gall, G.; Barillot, Christian; Gibaud, Bernard; Manens, Jean-Pierre; Toumoulin, Christine; Lemoine, Didier; Chenal, C.; Scarabin, Jean-Marie
1991-05-01
A Multibeam radiation therapy treatment is a non-invasive technique devoted to treat a lesion within the cerebral medium by focusing photon-beams on the same target from a high number of entrance points. We present here a computer assisted dosimetric planning procedure which includes: (1) an analysis module to define the target volume by using 2D and 3D displays, (2) a planing module to issue a treatment strategy including the dosimetric simulations and (3) a treatment module setting up the parameters to order the robotized treatment system (i.e. chair- framework, radiation unit machine). Another important feature of this system is its connection to the PACS system SIRENE settled in the University hospital of Rennes which makes possible the archiving and the communication of the multimodal images (CT, MRI, Angiography) used by this application. The corporate use of stereotactic methods and the multimodality imagery ensures spatial coherence and makes the target definition and the cognition of the structures environment more accurate. The dosimetric planning suited to the spatial reference (i.e. the stereotactic frame) guarantees an optimal distribution of the dose computed by an original 3D volumetric algorithm. The robotic approach of the treatment stage has consisted to design a computer driven chair-framework cluster to position the target volume at the radiation unit isocenter.
Furdová, Alena; Sramka, Miron; Thurzo, Andrej; Furdová, Adriana
2017-01-01
Objective The objective of this study was to determine the use of 3D printed model of an eye with intraocular tumor for linear accelerator-based stereotactic radiosurgery. Methods The software for segmentation (3D Slicer) created virtual 3D model of eye globe with tumorous mass based on tissue density from computed tomography and magnetic resonance imaging data. A virtual model was then processed in the slicing software (Simplify3D®) and printed on 3D printer using fused deposition modeling technology. The material that was used for printing was polylactic acid. Results In 2015, stereotactic planning scheme was optimized with the help of 3D printed model of the patient’s eye with intraocular tumor. In the period 2001–2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma and 11 ciliary body melanoma) were treated. The median tumor volume was 0.5 cm3 (0.2–1.6 cm3). The radiation dose was 35.0 Gy by 99% of dose volume histogram. Conclusion The 3D printed model of eye with tumor was helpful in planning the process to achieve the optimal scheme for irradiation which requires high accuracy of defining the targeted tumor mass and critical structures. PMID:28203052
NASA Astrophysics Data System (ADS)
Ehricke, Hans-Heino; Daiber, Gerhard; Sonntag, Ralf; Strasser, Wolfgang; Lochner, Mathias; Rudi, Lothar S.; Lorenz, Walter J.
1992-09-01
In stereotactic treatment planning the spatial relationships between a variety of objects has to be taken into account in order to avoid destruction of vital brain structures and rupture of vasculature. The visualization of these highly complex relations may be supported by 3-D computer graphics methods. In this context the three-dimensional display of the intracranial vascular tree and additional objects, such as neuroanatomy, pathology, stereotactic devices, or isodose surfaces, is of high clinical value. We report an advanced rendering method for a depth-enhanced maximum intensity projection from magnetic resonance angiography (MRA) and a walk-through approach to the analysis of MRA volume data. Furthermore, various methods for a multiple-object 3-D rendering in stereotaxy are discussed. The development of advanced applications in medical imaging can hardly be successful if image acquisition problems are disregarded. We put particular emphasis on the use of conventional MRI and MRA for stereotactic guidance. The problem of MR distortion is discussed and a novel three- dimensional approach to the quantification and correction of the distortion patterns is presented. Our results suggest that the sole use of MR for stereotactic guidance is highly practical. The true three-dimensionality of the acquired datasets opens up new perspectives to stereotactic treatment planning. For the first time it is possible now to integrate all the necessary information into 3-D scenes, thus enabling an interactive 3-D planning.
Pestel, Gunther J; Hiltebrand, Luzius B; Fukui, Kimiko; Cohen, Delphine; Hager, Helmut; Kurz, Andrea M
2006-10-01
We assessed changes in intravascular volume monitored by difference in pulse pressure (dPP%) after stepwise hemorrhage in an experimental pig model. Six pigs (23-25 kg) were anesthetized (isoflurane 1.5 vol%) and mechanically ventilated to keep end-tidal CO2 (etCO2) at 35 mmHg. A PA-catheter and an arterial catheter were placed via femoral access. During and after surgery, animals received lactated Ringer's solution as long as they were considered volume responders (dPP>13%). Then animals were allowed to stabilize from the induction of anesthesia and insertion of catheters for 30 min. After stabilization, baseline measurements were taken. Five percent of blood volume was withdrawn, followed by another 5%, and then in 10%-increments until death from exsanguination occurred. After withdrawal of 5% of blood volume, all pigs were considered volume responders (dPP>13%); dPP rose significantly from 6.1+/-3.3% to 19.4+/-4.2%. The regression analysis of stepwise hemorrhage revealed a linear relation between blood loss (hemorrhage in %) and dPP (y=0.99*x+14; R2=0.7764; P<.0001). In addition, dPP was the only parameter that changed significantly between baseline and a blood loss of 5% (P<0.01), whereas cardiac output, stroke volume, heart rate, MAP, central venous pressure, pulmonary artery occlusion pressure, and systemic vascular resistance, respectively, remained unchanged. We conclude that in an experimental hypovolemic pig model, dPP correlates well with blood loss.
Frameless, image-guided stereotactic radiosurgery.
Steffey-Stacy, Emily Cassandra
2006-11-01
To trace the evolution from frame-based to frameless image-guided SRS, to discuss the basic radiobiological principle of fractionation, current clinical trial data, and procedural components of the treatment plan. Nursing and medical literature, neurosurgical textbooks, and select internet sites. The CyberKnife (Accuray, Sunnyvale, CA) is the newest machine added to the technologic armamentarium of patient care. Its capacities are only beginning to be explored and the possibilities are limitless, giving hope to countless persons. Technologic advances have necessitated a diversification of nursing roles. Coordination of patient care services requires nurses to advance their knowledge of frameless, image-guided SRS.
Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Surry, K. J. M.; Mills, G. R.; Bevan, K.
2007-11-15
Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dimensional (2D), requiring a skilled physician for both safety and accuracy. The authors developed a 3D US-guided biopsy system to be integrated with, and to supplement SM imaging. Their goal is to be able to biopsy a larger percentage of suspicious masses using US, by clarifying ambiguous structures with SM imaging. Features from SM andmore » US guided biopsy were combined, including breast stabilization, a confined needle trajectory, and dual modality imaging. The 3D US guided biopsy system uses a 7.5 MHz breast probe and is mounted on an upright SM machine for preprocedural imaging. Intraprocedural targeting and guidance was achieved with real-time 2D and near real-time 3D US imaging. Postbiopsy 3D US imaging allowed for confirmation that the needle was penetrating the target. The authors evaluated 3D US-guided biopsy accuracy of their system using test phantoms. To use mammographic imaging information, they registered the SM and 3D US coordinate systems. The 3D positions of targets identified in the SM images were determined with a target localization error (TLE) of 0.49 mm. The z component (x-ray tube to image) of the TLE dominated with a TLE{sub z} of 0.47 mm. The SM system was then registered to 3D US, with a fiducial registration error (FRE) and target registration error (TRE) of 0.82 and 0.92 mm, respectively. Analysis of the FRE and TRE components showed that these errors were dominated by inaccuracies in the z component with a FRE{sub z} of 0.76 mm and a TRE{sub z} of 0.85 mm. A stereotactic mammography and 3D US guided breast biopsy system should include breast compression for stability and safety and dual modality imaging for target localization. The system will provide preprocedural x-ray mammography information in the form of SM imaging along with real-time US imaging for needle guidance to a target. 3D US imaging will also be available for targeting, guidance, and biopsy verification immediately postbiopsy.« less
Gamma Knife radiosurgery for the treatment of intracranial dural arteriovenous fistulas
Dmytriw, Adam A; Schwartz, Michael L; Cusimano, Michael D; Mendes Pereira, Vitor; Krings, Timo; Tymianski, Michael; Radovanovic, Ivan
2016-01-01
Background Intracranial dural arteriovenous fistulae (DAVF) may present a treatment challenge. Endovascular embolization is in most cases the first line of treatment but does not always achieve cure. Gamma Knife (GK) radiosurgery represents an alternative treatment option, and the purpose of this study was to further evaluate its utility. Methods We reviewed all cases of DAVF treated between 2009 and 2016 at our institution with GK radiosurgery independently, or following failed/refused endovascular or surgical management. Patients’ clinical files, radiological images, catheter angiograms, and surgical DAVF disconnection reports were retrospectively reviewed. Results Sixteen DAVF (14 patients) treated by GK radiosurgery were identified. Eleven fistulae were aggressive and five were benign. Marginal doses ranged from 15 to 25 Gy. Target volumes ranged from 0.04 to 4.47 cm3. In all symptomatic patients, GK treatment resulted in symptom palliation. In 13/15 lesions, cure of symptoms (86.0%) was reported. One lesion was asymptomatic. Angiographic cure was achieved in eight cases (50%), small residual DAVF occurred in four, and four were unchanged. One patient developed headache that resolved at one year. No hemorrhage occurred during the follow-up period. There was no significant association between Borden type and cure rate. Prior failed endovascular treatment and small target volume were associated with lower rates of cure. Conclusions Stereotactic radiosurgery is viable treatment for DAVF. It is very effective in palliating symptoms as a de novo approach or adjunctive to endovascular therapy. In our experience it is only somewhat effective in achieving complete angiographic cure. PMID:28156167
NASA Astrophysics Data System (ADS)
Jang, Bo Shim; Suk, Lee; Sam, Ju Cho; Sang, Hoon Lee; Juree, Kim; Kwang, Hwan Cho; Chul, Kee Min; Hyun Do, Huh; Rena, Lee; Dae, Sik Yang; Young, Je Park; Won, Seob Yoon; Chul, Yong Kim; Soo, Il Kwon
2010-11-01
This study compares and analyzes stereotactic radiotherapy using tomotherapy and linac-based fractionated stereotactic radiotherapy in the treatment of intra-cranial tumors, according to some cases. In this study, linac-based fractionated stereotactic radiotherapy and tomotherapy treatment were administered to five patients diagnosed with intra-cranial cancer in which the dose of 18-20 Gy was applied on 3-5 separate occasions. The tumor dosing was decided by evaluating the inhomogeneous index (II) and conformity index (CI). Also, the radiation-sensitive tissue was evaluated using low dose factors V1, V2, V3, V4, V5, and V10, as well as the non-irradiation ratio volume (NIV). The values of the II for each prescription dose in the linac-based non-coplanar radiotherapy plan and tomotherapy treatment plan were (0.125±0.113) and (0.090±0.180), respectively, and the values of the CI were (0.899±0.149) and (0.917±0.114), respectively. The low dose areas, V1, V2, V3, V4, V5, and V10, in radiation-sensitive tissues in the linac-based non-coplanar radiotherapy plan fell into the ranges 0.3%-95.6%, 0.1%-87.6%, 0.1%-78.8%, 38.8%-69.9%, 26.6%-65.2%, and 4.2%-39.7%, respectively, and the tomotherapy treatment plan had ranges of 13.6%-100%, 3.5%-100%, 0.4%-94.9%, 0.2%-82.2%, 0.1%-78.5%, and 0.3%-46.3%, respectively. Regarding the NIV for each organ, it is possible to obtain similar values except for the irradiation area of the brain stem. The percentages of NIV 10%, NIV20%, and NIV30%for the brain stem in each patient were 15%-99.8%, 33.4%-100%, and 39.8%-100%, respectively, in the fractionated stereotactic treatment plan and 44.2%-96.5%, 77.7%-99.8%, and 87.8%-100%, respectively, in the tomotherapy treatment plan. In order to achieve higher-quality treatment of intra-cranial tumors, treatment plans should be tailored according to the isodose target volume, inhomogeneous index, conformity index, position of the tumor upon fractionated stereotactic radiosurgery, and radiation dosage for radiation-sensitive tissues.
Navigation-guided optic canal decompression for traumatic optic neuropathy: Two case reports.
Bhattacharjee, Kasturi; Serasiya, Samir; Kapoor, Deepika; Bhattacharjee, Harsha
2018-06-01
Two cases of traumatic optic neuropathy presented with profound loss of vision. Both cases received a course of intravenous corticosteroids elsewhere but did not improve. They underwent Navigation guided optic canal decompression via external transcaruncular approach, following which both cases showed visual improvement. Postoperative Visual Evoked Potential and optical coherence technology of Retinal nerve fibre layer showed improvement. These case reports emphasize on the role of stereotactic navigation technology for optic canal decompression in cases of traumatic optic neuropathy.
The treatment of recurrent brain metastases with stereotactic radiosurgery.
Loeffler, J S; Kooy, H M; Wen, P Y; Fine, H A; Cheng, C W; Mannarino, E G; Tsai, J S; Alexander, E
1990-04-01
Between May 1986 and August 1989, we treated 18 patients with 21 recurrent or persistent brain metastases with stereotactic radiosurgery using a modified linear accelerator. To be eligible for radiosurgery, patients had to have a performance status of greater than or equal to 70% and have no evidence of (or stable) systemic disease. All but one patient had received prior radiotherapy, and were treated with stereotactic radiosurgery at the time of recurrence. Polar lesions were treated only if the patient had undergone and failed previous complete surgical resection (10 patients). Single doses of radiation (900 to 2,500 cGy) were delivered to limited volumes (less than 27 cm3) using a modified 6MV linear accelerator. The most common histology of the metastatic lesion was carcinoma of the lung (seven patients), followed by carcinoma of the breast (four patients), and melanoma (four patients). With median follow-up of 9 months (range, 1 to 39), all tumors have been controlled in the radiosurgery field. Two patients failed in the immediate margin of the treated volume and were subsequently treated with surgery and implantation of 125I to control the disease. Radiographic response was dramatic and rapid in the patients with adenocarcinoma, while slight reduction and stabilization occurred in those patients with melanoma, renal cell carcinoma, and sarcoma. The majority of patients improved neurologically following treatment, and were able to be withdrawn from corticosteroid therapy. Complications were limited and transient in nature and no cases of symptomatic radiation necrosis occurred in any patient despite previous exposure to radiotherapy. Stereotactic radiosurgery is an effective and relatively safe treatment for recurrent solitary metastases and is an appealing technique for the initial management of deep-seated lesions as a boost to whole brain radiotherapy.
Henzel, Martin; Hamm, Klaus; Sitter, Helmut; Gross, Markus W; Surber, Gunnar; Kleinert, Gabriele; Engenhart-Cabillic, Rita
2009-09-01
Stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. From 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up > or = 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and 87.5%/87.2% (SRT). TV shrinkage was 15.1%/40.7% (SRS/SRT; p = 0.01). Single dose (< 13 Gy) was the only determinant factor for TV shrinkage after SRS (p = 0.001). Age, gender, initial TV, and previous operations did not affect TV shrinkage. Acute or late toxicity (> or = grade 3) was never seen. Concerning QoL, no significant differences were observed after SRS/SRT. Previous operations and gender did not affect QoL (p > 0.05). Compared with the German normal population, patients had worse values for all domains except for mental health. TV shrinkage was significantly higher after SRT than after SRS. Main symptoms were not affected by SRS/SRT. Retrospectively, QoL was neither affected by SRS nor by SRT.
Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields
NASA Astrophysics Data System (ADS)
McNiven, Andrea L.
The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the computed tomography dose index (CTDI), a concept normally used in diagnostic radiology. This involved experimental determination of the fan beam thickness using the ion chambers to acquire fan beam profiles and extrapolation to a 'zero-size' detector. In conclusion, improvements have been made in the accuracy of small field dosimetry measurements in stereotactic radiotherapy and helical tomotherapy. This was completed through introduction of an original technique involving micro-CT imaging for sensitive volume determination and potentially ion chamber calibration coefficients, the use of appropriate Monte Carlo derived correction factors for RDF measurement, and the exploitation of the partial volume effect for helical tomotherapy fan beam dosimetry. With improved dosimetry for a wide range of challenging small x-ray field situations, it is expected that the patient's radiation safety will be maintained, and that clinical trials will adopt calibration protocols specialized for modern radiotherapy with small fields or beamlets. Keywords. radiation therapy, ionization chambers, small field dosimetry, stereotactic radiotherapy, helical tomotherapy, micro-CT.
Gamma Knife irradiation method based on dosimetric controls to target small areas in rat brains
DOE Office of Scientific and Technical Information (OSTI.GOV)
Constanzo, Julie; Paquette, Benoit; Charest, Gabriel
2015-05-15
Purpose: Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The purpose of this work is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Methods: Euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomography (CT), to estimate positioning variations relative to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates obtained from CT images, different regions of the brainmore » were delimited and a treatment plan was generated. A single isocenter treatment plan delivering ≥100 Gy in 100% of the target volume was produced by Leksell GammaPlan using the 4 mm diameter collimator of sectors 4, 5, 7, and 8 of the Gamma Knife unit. Impact of positioning deviations of the rat brain on dose deposition was simulated by GammaPlan and validated with dosimetric measurements. Results: The authors’ results showed that 90% of the target volume received 100 ± 8 Gy and the maximum of deposited dose was 125 ± 0.7 Gy, which corresponds to an excellent relative standard deviation of 0.6%. This dose deposition calculated with GammaPlan was validated with dosimetric films resulting in a dose-profile agreement within 5%, both in X- and Z-axes. Conclusions: The authors’ results demonstrate the feasibility of standardizing the irradiation procedure of a small volume in the rat brain using a Gamma Knife.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapoor, Sumit; Batra, Sachin; Carson, Kathryn
2011-11-01
Purpose: We assessed clinical outcome and long-term tumor control after fractionated stereotactic radiotherapy (FSRT) for unilateral schwannoma. Methods and Materials: Between 1995 and 2007, 496 patients were treated with fractionated stereotactic radiotherapy at Johns Hopkins Hospital (Baltimore, MD); 385 patients had radiologic follow-up that met the inclusion criteria. The primary endpoint was treatment failure. Secondary endpoints were radiologic progression and clinical outcome. Logistic regression analysis assessed the association of age, race, tumor side, sex, and pretreatment symptoms. Results: In 11 patients (3%) treatment failed, and they required salvage (microsurgical) treatment. Radiologic progression was observed in 116 patients (30.0%), including 35more » patients (9%) in whom the treatment volume more than doubled during the follow-up period, although none required surgical resection. Tumors with baseline volumes of less than 1 cm{sup 3} were 18.02 times more likely to progress than those with tumor volumes of 1 cm{sup 3} or greater (odds ratio, 18.02; 95% confidence interval, 4.25-76.32). Treatment-induced neurologic morbidity included 8 patients (1.6%) with new facial weakness, 12 patients (2.8%) with new trigeminal paresthesias, 4 patients (0.9%) with hydrocephalus (1 communicating and 3 obstructive), and 2 patients (0.5%) with possibly radiation-induced neoplasia. Conclusions: Although the rate of treatment failure is low (3%), careful follow-up shows that radiologic progression occurs frequently. When reporting outcome, the 'no salvage surgery needed' and 'no additional treatment needed' criteria for treatment success need to be complemented by the radiologic data.« less
Proton beam radiosurgery for vestibular schwannoma: tumor control and cranial nerve toxicity.
Weber, Damien C; Chan, Annie W; Bussiere, Marc R; Harsh, Griffith R; Ancukiewicz, Marek; Barker, Fred G; Thornton, Allan T; Martuza, Robert L; Nadol, Joseph B; Chapman, Paul H; Loeffler, Jay S
2003-09-01
We sought to determine the tumor control rate and cranial nerve function outcomes in patients with vestibular schwannomas who were treated with proton beam stereotactic radiosurgery. Between November 1992 and August 2000, 88 patients with vestibular schwannomas were treated at the Harvard Cyclotron Laboratory with proton beam stereotactic radiosurgery in which two to four convergent fixed beams of 160-MeV protons were applied. The median transverse diameter was 16 mm (range, 2.5-35 mm), and the median tumor volume was 1.4 cm(3) (range, 0.1-15.9 cm(3)). Surgical resection had been performed previously in 15 patients (17%). Facial nerve function (House-Brackmann Grade 1) and trigeminal nerve function were normal in 79 patients (89.8%). Eight patients (9%) had good or excellent hearing (Gardner-Robertson [GR] Grade 1), and 13 patients (15%) had serviceable hearing (GR Grade 2). A median dose of 12 cobalt Gray equivalents (range, 10-18 cobalt Gray equivalents) was prescribed to the 70 to 108% isodose lines (median, 70%). The median follow-up period was 38.7 months (range, 12-102.6 mo). The actuarial 2- and 5-year tumor control rates were 95.3% (95% confidence interval [CI], 90.9-99.9%) and 93.6% (95% CI, 88.3-99.3%). Salvage radiosurgery was performed in one patient 32.5 months after treatment, and a craniotomy was required 19.1 months after treatment in another patient with hemorrhage in the vicinity of a stable tumor. Three patients (3.4%) underwent shunting for hydrocephalus, and a subsequent partial resection was performed in one of these patients. The actuarial 5-year cumulative radiological reduction rate was 94.7% (95% CI, 81.2-98.3%). Of the 21 patients (24%) with functional hearing (GR Grade 1 or 2), 7 (33.3%) retained serviceable hearing ability (GR Grade 2). Actuarial 5-year normal facial and trigeminal nerve function preservation rates were 91.1% (95% CI, 85-97.6%) and 89.4% (95% CI, 82-96.7%). Univariate analysis revealed that prescribed dose (P = 0.005), maximum dose (P = 0.006), and the inhomogeneity coefficient (P = 0.03) were associated with a significant risk of long-term facial neuropathy. No other cranial nerve deficits or cancer relapses were observed. Proton beam stereotactic radiosurgery has been shown to be an effective means of tumor control. A high radiological response rate was observed. Excellent facial and trigeminal nerve function preservation rates were achieved. A reduced prescribed dose is associated with a significant decrease in facial neuropathy.
Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young
2011-02-01
Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.
Imai, Takahiko; Takagi, Toshinori; Kitashoji, Akira; Yamauchi, Keita; Shimazawa, Masamitsu; Hara, Hideaki
2016-05-01
Oxidative stress has been reported to be a main cause of neuronal cell death in ischemia reperfusion injury (IRI). Nuclear factor-erythroid 2-related factor 2 (Nrf2) is an important factor involved in anti-oxidative responses. We previously reported that bardoxolone methyl (BARD), an Nrf2 activator, prevented damage induced by IRI. In this study, we investigated the effect of BARD on hemorrhagic transformation in the context of blood brain barrier (BBB) protection. Mice received pre-treatment with warfarin (4.0 mg/kg, p.o.). IRI was subsequently induced 18 h after the warfarin administration by transient middle cerebral artery occlusion (MCAO) for 6 h. BARD (0.06, 0.2, 0.6 or 2.0 mg/kg) or saline was injected intravenously immediately after reperfusion. The infarct volume, neurological score, intracranial hemorrhage volume, and BBB permeability were evaluated 24 h after MCAO. The survival rate and behavioral functional recovery were evaluated for 7 days following IRI. Furthermore, the effects of BARD on BBB components were investigated by western blotting and immunostaining analysis. BARD suppressed warfarin-mediated increases in the intracranial hemorrhage volume without affecting the infarct volume. BBB permeability was also suppressed by administration of BARD. Western blotting showed that BARD increased expression of BBB components such as endothelial cells, pericytes, and tight junction proteins. Furthermore, immunostaining showed that BARD induced localization of Nrf2 to endothelial cells and pericytes. BARD suppressed the exacerbation hemorrhage caused by warfarin pretreatment and ameliorated BBB disruption by protecting endothelial cells, pericytes, and tight junction protein expressions. These results indicate that Nrf2 activators may be an effective therapy against hemorrhagic transformation caused by anticoagulant drugs. Copyright © 2016 Elsevier Inc. All rights reserved.
Nowinski, Wieslaw L; Chua, Beng Choon; Volkau, Ihar; Puspitasari, Fiftarina; Marchenko, Yevgen; Runge, Val M; Knopp, Michael V
2010-12-01
The most severe complication of deep brain stimulation (DBS) is intracranial hemorrhage. Detailed knowledge of the cerebrovasculature could reduce the rate of this disorder. Morphological scans typically acquired in stereotactic and functional neurosurgery (SFN) by using 1.5-T (or sometimes even 3-T) imaging units poorly depict the vasculature. Advanced angiographic imaging, including 3- and 7-T 3D time-of-flight and susceptibility weighted imaging as well as 320-slice CT angiography, depict the vessels in great detail. However, these acquisitions are not used in SFN clinical practice, and robust methods for their processing are not available yet. Therefore, the authors proposed the use of a detailed 3D stereotactic cerebrovascular atlas to assist in SFN planning and to potentially reduce DBS-induced hemorrhage. A very detailed 3D cerebrovascular atlas of arteries, veins, and dural sinuses was constructed from multiple 3- and 7-T scans. The atlas contained>900 vessels, each labeled with a name and diameter with the smallest having a 90-μm diameter. The cortical areas, ventricular system, and subcortical structures were fully segmented and labeled, including the main stereotactic target structures: subthalamic nucleus, ventral intermediate nucleus of the thalamus, and internal globus pallidus. The authors also developed a computer simulator with the embedded atlas that was able to compute the effective electrode trajectory by minimizing penetration of the cerebrovascular system and vital brain structures by a DBS electrode. The simulator provides the neurosurgeon with functions for atlas manipulation, target selection, trajectory planning and editing, 3D display and manipulation, and electrode-brain penetration calculation. This simulation demonstrated that a DBS electrode inserted in the middle frontal gyrus may intersect several arteries and veins including 1) the anteromedial frontal artery of the anterior cerebral artery as well as the prefrontal artery and the precentral sulcus artery of the middle cerebral artery (range of diameters 0.4-0.6 mm); and 2) the prefrontal, anterior caudate, and medullary veins (range of diameters 0.1-2.3 mm). This work also shows that field strength and pulse sequence have a substantial impact on vessel depiction. The numbers of 3D vascular segments are 215, 363, and 907 for 1.5-, 3-, and 7-T scans, respectively. Inserting devices into the brain during microrecording and stimulation may cause microbleeds not discernible on standard scans. A small change in the location of the DBS electrode can result in a major change for the patient. The described simulation increases the neurosurgeon's awareness of this phenomenon. The simulator enables the neurosurgeon to analyze the spatial relationships between the track and the cerebrovasculature, ventricles, subcortical structures, and cortical areas, which allows the DBS electrode to be placed more effectively, and thus potentially reducing the invasiveness of the stimulation procedure for the patient.
Li, Winnie; Cho, Young-Bin; Ansell, Steve; Laperriere, Normand; Ménard, Cynthia; Millar, Barbara-Ann; Zadeh, Gelareh; Kongkham, Paul; Bernstein, Mark; Jaffray, David A; Chung, Caroline
2016-09-01
The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board-approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was -0.19 ± 0.32, 0.06 ± 0.27, and -0.23 ± 0.2 mm, with a maximum of -0.74, -0.53, and -0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was -0.03 ± 0.05, -0.03 ± 0.18, and -0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non-frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction discrepancy when moving to a frameless approach. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Morimoto, Masahiro; Yoshioka, Yasuo; Kotsuma, Tadayuki; Adachi, Kana; Shiomi, Hiroya; Suzuki, Osamu; Seo, Yuji; Koizumi, Masahiko; Kagawa, Naoki; Kinoshita, Manabu; Hashimoto, Naoya; Ogawa, Kazuhiko
2013-08-01
To retrospectively examine the outcomes of hypofractionated stereotactic radiation therapy in three to five fractions for vestibular schwannomas. Twenty-five patients with 26 vestibular schwannomas were treated with hypofractionated stereotactic radiation therapy using a CyberKnife. The vestibular schwannomas of 5 patients were associated with type II neurofibromatosis. The median follow-up time was 80 months (range: 6-167); the median planning target volume was 2.6 cm(3) (0.3-15.4); and the median prescribed dose (≥D90) was 21 Gy in three fractions (18-25 Gy in three to five fractions). Progression was defined as ≥2 mm 3-dimensional post-treatment tumor enlargement excluding transient expansion. Progression or any death was counted as an event in progression-free survival rates, whereas only progression was counted in progression-free rates. The 7-year progression-free survival and progression-free rates were 78 and 95%, respectively. Late adverse events (≥3 months) with grades based on Common Terminology Criteria for Adverse Events, v4.03 were observed in 6 patients: Grade 3 hydrocephalus in one patient, Grade 2 facial nerve disorders in two and Grade 1-2 tinnitus in three. In total, 12 out of 25 patients maintained pure tone averages ≤50 dB before hypofractionated stereotactic radiation therapy, and 6 of these 12 patients (50%) maintained pure tone averages at this level at the final audiometric follow-up after hypofractionated stereotactic radiation therapy. However, gradient deterioration of pure tone average was observed in 11 of these 12 patients. The mean pure tone averages before hypofractionated stereotactic radiation therapy and at the final follow-up for the aforementioned 12 patients were 29.8 and 57.1 dB, respectively. Treating vestibular schwannomas with hypofractionated stereotactic radiation therapy in three to five fractions may prevent tumor progression with tolerable toxicity. However, gradient deterioration of pure tone average was observed.
[Peritumoral hemorrhage immediately after radiosurgery for metastatic brain tumor].
Uchino, Masafumi; Kitajima, Satoru; Miyazaki, Chikao; Otsuka, Takashi; Seiki, Yoshikatsu; Shibata, Iekado
2003-08-01
We report a case of a 44-year-old woman with metastatic brain tumors who suffered peri-tumoral hemorrhage soon after stereotactic radiosurgery (SRS). She had been suffering from breast cancer with multiple systemic metastasis. She started to have headache, nausea, dizziness and speech disturbance 1 month before admission. There was no bleeding tendency in the hematological examination and the patient was normotensive. Neurological examination disclosed headache and slightly aphasia. Magnetic resonance imaging showed a large round mass lesion in the left temporal lobe. It was a well-demarcated, highly enhanced mass, 45 mm in diameter. SRS was performed on four lesions in a single session (Main mass: maximum dose was 30 Gy in the center and 20 Gy in the margin of the tumor. Others: maximum 25 Gy margin 20 Gy). After radiosurgery, she had severe headache, nausea and vomiting and showed progression of aphasia. CT scan revealed a peritumoral hemorrhage. Conservative therapy was undertaken and the patient's symptoms improved. After 7 days, she was discharged, able to walk. The patient died of extensive distant metastasis 5 months after SRS. Acute transient swelling following conventional radiotherapy is a well-documented phenomenon. However, the present case indicates that such an occurrence is also possible in SRS. We have hypothesized that acute reactions such as brain swelling occur due to breakdown of the fragile vessels of the tumor or surrounding tissue.
Pan, Patrick J; Bansal, Anshuman K; Genshaft, Scott J; Kim, Grace H; Suh, Robert D; Abtin, Fereidoun
2018-05-01
To determine size of ablation zone and pulmonary hemorrhage in double-freeze (DF) vs modified triple-freeze (mTF) cryoablation protocols with different probe sizes in porcine lung. In 10 healthy adult pigs, 20 pulmonary cryoablations were performed using either a 2.4-mm or a 1.7-mm probe. Either conventional DF or mTF protocol was used. Serial noncontrast CT scans were performed during ablations. Ablation iceball and hemorrhage volumes were measured and compared between protocols and probe sizes. With 1.7-mm probe, greater peak iceball volume was observed with DF compared with mTF, although difference was not statistically significant (16.1 mL ± 1.9 vs 8.8 mL ± 3.6, P = .07). With 2.4-mm probe, DF and mTF produced similar peak iceball volumes (14.0 mL ± 2.8 vs 14.6 mL ± 2.7, P = .88). Midcycle hemorrhage was significantly larger with DF with the 1.7-mm probe (94.3 mL ± 22.2 vs 19.6 mL ± 2.1, P = .02) and with both sizes combined (93.2 mL ± 17.5 vs. 50.9 mL ± 12.6, P = .048). Rate of hemorrhage increase was significantly higher in DF (10.4 mL/min vs 5.1 mL/min, P = .003). End-cycle hemorrhage was visibly larger in DF compared with mTF across probe sizes, although differences were not statistically significant (P = .14 for 1.7 mm probe, P = .18 for 2.4 mm probe, and P = .07 for both probes combined). Rate of increase in hemorrhage during the last thaw period was not statistically different between DF and mTF (3.0 mL/min vs 2.8 mL/min, P = .992). mTF reduced rate of midcycle hemorrhage compared with DF. With mTF, midcycle hemorrhage was significantly smaller with 1.7-mm probe; although noticeably smaller with 2.4-mm probe, statistical significance was not achieved. Iceball size was not significantly different across both protocols and probe types. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Dosimetric impact of a change in breathing period on VMAT stereotactic ablative body radiotherapy
NASA Astrophysics Data System (ADS)
Olding, T.; Alexander, KM
2017-05-01
The dosimetric impact of a change in breathing period during treatment was assessed for a volumetric modulated arc therapy (VMAT) stereotactic ablative radiotherapy (SABR) lung plan optimized according to our centre’s planning protocol. Plan delivery was evaluated at three breathing rates ranging from 7 to 23 breaths-per-minute (BPM) against the planning anatomy (15 BPM) calculated dose. Dynamic ion chamber, EBT3 film and Fricke-xylenol orange-gelatin (FXG) gel measurements were acquired using a motion phantom with appropriate inserts for each dosimeter. The results show good agreement between measured and calculated plan dose within the internal gross tumour volume (IGTV) target.
Construction of a Cerebral Hemorrhage Test System Operated in Real-time
NASA Astrophysics Data System (ADS)
Li, Gen; Sun, Jian; Ma, Ke; Yan, Qingguang; Zheng, Xiaolin; Qin, Mingxin; Jin, Gui; Ning, Xu; Zhuang, Wei; Feng, Hua; Huang, Shiyuwei
2017-02-01
The real-time monitoring and evaluation of the severity and progression of cerebral hemorrhage is essential to its intensive care and its successful emergency treatment. Based on magnetic induction phase shift technology combined with a PCI data acquisition system and LabVIEW software, this study established a real-time monitoring system for cerebral hemorrhage. To test and evaluate the performance of the system, the authors performed resolution conductivity experiments, salted water simulation experiments and cerebral hemorrhage experiments in rabbits and found that when the conductivity difference was 0.73 S/m, the phase difference was 13.196°. The phase difference change value was positively proportional to the volume of saline water, and the conductivity value was positively related to the phase difference of liquid under the same volume conditions. After injecting 3 mL blood into six rabbits, the average change in the blood phase difference was -2.03783 ± 0.22505°, and it was positively proportional to the volume of blood, which was consistent with the theoretical results. The results show that the system can monitor the progressive development of cerebral hemorrhage in real-time and has the advantages of low cost, small size, high phase accuracy, and good clinical application potentiality.
Neggers, S F W; Langerak, T R; Schutter, D J L G; Mandl, R C W; Ramsey, N F; Lemmens, P J J; Postma, A
2004-04-01
Transcranial Magnetic Stimulation (TMS) delivers short magnetic pulses that penetrate the skull unattenuated, disrupting neural processing in a noninvasive, reversible way. To disrupt specific neural processes, coil placement over the proper site is critical. Therefore, a neural navigator (NeNa) was developed. NeNa is a frameless stereotactic device using structural and functional magnetic resonance imaging (fMRI) data to guide TMS coil placement. To coregister the participant's head to his MRI, 3D cursors are moved to anatomical landmarks on a skin rendering of the participants MRI on a screen, and measured at the head with a position measurement device. A method is proposed to calculate a rigid body transformation that can coregister both sets of coordinates under realistic noise conditions. After coregistration, NeNa visualizes in real time where the device is located with respect to the head, brain structures, and activated areas, enabling precise placement of the TMS coil over a predefined target region. NeNa was validated by stimulating 5 x 5 positions around the 'motor hotspot' (thumb movement area), which was marked on the scalp guided by individual fMRI data, while recording motor-evoked potentials (MEPs) from the abductor pollicis brevis (APB). The distance between the center of gravity (CoG) of MEP responses and the location marked on the scalp overlying maximum fMRI activation was on average less then 5 mm. The present results demonstrate that NeNa is a reliable method for image-guided TMS coil placement.
Immunotherapy and stereotactic ablative radiotherapy (ISABR): a curative approach?
Bernstein, Michael B; Krishnan, Sunil; Hodge, James W; Chang, Joe Y
2016-08-01
Conventional radiotherapy, in addition to its well-established tumoricidal effects, can also activate the host immune system. Radiation therapy modulates tumour phenotypes, enhances antigen presentation and tumour immunogenicity, increases production of cytokines and alters the tumour microenvironment, enabling destruction of the tumour by the immune system. Investigating the combination of radiotherapy with immunotherapeutic agents, which also promote the host antitumour immune response is, therefore, a logical progression. As the spectrum of clinical use of stereotactic radiotherapy continues to broaden, the question arose as to whether the ablative radiation doses used can also stimulate immune responses and, if so, whether we can amplify these effects by combining immunotherapy and stereotactic ablative radiotherapy (SABR). In this Perspectives article, we explore the preclinical and clinical evidence supporting activation of the immune system following SABR. We then examine studies that provide data on the effectiveness of combining these two techniques - immunotherapy and SABR - in an approach that we have termed 'ISABR'. Lastly, we provide general guiding principles for the development of future clinical trials to investigate the efficacy of ISABR in the hope of generating further interest in these exciting developments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, Daniel, E-mail: daniel.pham@petermac.org; Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, Victoria; Thompson, Ann
Purpose: To describe our 3-dimensional conformal planning approaches and report early toxicities with stereotactic body radiation therapy for the management of primary renal cell carcinoma. Methods and Materials: This is an analysis of a phase 1 trial of stereotactic body radiation therapy for primary inoperable renal cell carcinoma. A dose of 42 Gy/3 fractions was prescribed to targets ≥5 cm, whereas for <5 cm 26 Gy/1 fraction was used. All patients underwent a planning 4-dimensional CT to generate a planning target volume (PTV) from a 5-mm isotropic expansion of the internal target volume. Planning required a minimum of 8 fields prescribing to the minimummore » isodose surrounding the PTV. Intermediate dose spillage at 50% of the prescription dose (R50%) was measured to describe the dose gradient. Early toxicity (<6 months) was scored using the Common Terminology Criteria for Adverse Events (v4.0). Results: From July 2012 to August 2013 a total of 20 patients (median age, 77 years) were recruited into a prospective clinical trial. Eleven patients underwent fractionated treatment and 9 patients a single fraction. For PTV targets <100 cm{sup 3} the median number of beams used was 8 (2 noncoplanar) to achieve an average R50% of 3.7. For PTV targets >100 cm{sup 3} the median beam number used was 10 (4 noncoplanar) for an average R50% value of 4.3. The R50% was inversely proportional to decreasing PTV volume (r=−0.62, P=.003) and increasing total beams used (r=−0.51, P=.022). Twelve of 20 patients (60%) suffered grade ≤2 early toxicity, whereas 8 of 20 patients (40%) were asymptomatic. Nausea, chest wall pain, and fatigue were the most common toxicities reported. Conclusion: A 3-dimensional conformal planning technique of 8-10 beams can be used to deliver highly tolerable stereotactic ablation to primary kidney targets with minimal early toxicities. Ongoing follow-up is currently in place to assess long-term toxicities and cancer control.« less
2015-01-01
different PRBC transfusion volumes. We performed multivariate regression analysis using HRV metrics and routine vital signs to test the hypothesis that...study sponsors did not have any role in the study design, data collection, analysis and interpretation of data, report writing, or the decision to...primary outcome was hemorrhagic injury plus different PRBC transfusion volumes. We performed multivariate regression analysis using HRV metrics and
Rivera-Lara, Lucia; Murthy, Santosh B; Nekoovaght-Tak, Saman; Ali, Hasan; McBee, Nichol; Dlugash, Rachel; Ram, Malathi; Thompson, Richard; Awad, Issam A; Hanley, Daniel F; Ziai, Wendy C
2018-03-27
Concomitant acute ischemic lesions are detected in up to a quarter of patients with spontaneous intracerebral hemorrhage (ICH). Influence of bleeding pattern and intraventricular hemorrhage (IVH) on risk of ischemic lesions has not been investigated. Retrospective study of all 500 patients enrolled in the CLEAR III randomized controlled trial of thrombolytic removal of obstructive IVH using external ventricular drainage. The primary outcome measure was radiologically confirmed ischemic lesions, as reported by the Safety Event Committee and confirmed by two neurologists. We assessed predictors of ischemic lesions including analysis of bleeding patterns (ICH, IVH and subarachnoid hemorrhage) on computed tomography scans (CT). Secondary outcomes were blinded assessment of mortality and modified Rankin scale (mRS) at 30 and 180 days. Ischemic lesions occurred in 23 (4.6%) during first 30 days after ICH. Independent risk factors associated with ischemic lesions in logistic regression models adjusted for confounders were higher IVH volume (p = 0.004) and persistent subarachnoid hemorrhage on CT scan (p = 0.03). Patients with initial IVH volume ≥ 15 ml had five times the odds of concomitant ischemic lesions compared to IVH volume < 15 ml. Patients with ischemic lesions had significantly higher odds of death at 1 and 6 months (but not poor outcome; mRS 4-6) compared to patients without concurrent ischemic lesions. Occurrence of ischemic lesions in the acute phase of IVH is not uncommon and is significantly associated with increased early and late mortality. Extra-parenchymal blood (larger IVH and visible subarachnoid hemorrhage) is a strong predictor for development of concomitant ischemic lesions after ICH.
James, Michael L.; Blessing, Robert; Bennett, Ellen; Laskowitz, Daniel T.
2009-01-01
Introduction To address the mechanisms by which apoE polymorphism affects functional outcome after intracerebral hemorrhage in humans, we tested the hypothesis that the presence of the APOE4 allele results in amplified inflammatory responses and increased cerebral edema. Methods We prospectively enrolled and collected data on 21 adult patients consecutively admitted to Duke University Hospital with supratentorial intracerebral hematoma including hemorrhage volume, midline shift, modified Rankin Score, Glasgow Outcome Score, and APOE genotype. Hemorrhage size (cm3) and midline shift (mm), at the level of the thalamus, were measured by computed tomography within 36 hours of admission. Rankin and Glasgow Scores were determined at discharge. Student’s t-test was used to analyze hemorrhage size, midline shift, and Glasgow Outcome Score and logistical regression was used to measure allele affect on modified Rankin Score. When analyzing modified Rankin Score, patients were grouped by favorable outcome (0–2) or unfavorable (3–6). Results Out of 21 patients, 11 possessed at least one APOE4 allele (APOE4+). There was no difference in hemorrhage volume (25.8 v. 38.3 mm for APOE4− v. APOE4+, respectively) between the groups, but there was a significant difference in midline shift (p=0.04, 0.7 v. 4mm). Functional outcomes were worse for the patients possessing at least one APOE4 allele (p=0.04) Conclusion The presence of APOE4 is associated with poor functional outcomes in humans after intracerebral hemorrhage. Our data suggest that the mechanism for this may be increased cerebral edema and not larger hematoma volume. PMID:19251191
Hawasli, Ammar H; Ray, Wilson Z; Murphy, Rory K J; Dacey, Ralph G; Leuthardt, Eric C
2012-06-01
To describe the novel use of the AutoLITT System (Monteris Medical, Winnipeg, Manitoba, Canada) for focused laser interstitial thermal therapy (LITT) with intraoperative magnetic resonance imaging (MRI) and stereotactic image guidance for the treatment of metastatic adenocarcinoma in the left insula. The patient was a 61-year-old right-handed man with a history of metastatic adenocarcinoma of the colon. He had previously undergone resection of multiple lesions, Gamma Knife radiosurgery, and whole-brain radiation. Despite treatment of a left insular tumor, serial imaging revealed that the lesion continued to enlarge. Given the refractory nature of this tumor to radiation and the deep-seated location, the patient elected to undergo LITT treatment. The center of the lesion and entry point on the scalp were identified with STEALTH (Medtronic, Memphis, Tennessee) image-guided navigation. The AXiiiS Stereotactic Miniframe (Monteris Medical) for the LITT system was secured onto the skull, and a trajectory was defined to achieve access to the centroid of the tumor. After a burr hole was made, a gadolinium template probe was inserted into the AXiiiS base. The trajectory was confirmed via an intraoperative MRI, and the LITT probe driver was attached to the base and CO2-cooled, side-firing laser LITT probe. The laser was activated and thermometry images were obtained. Two trajectories, posteromedial and anterolateral, produced satisfactory tumor ablation. LITT with intraoperative MRI and stereotactic image guidance is a newly available, minimally invasive, and therapeutically viable technique for the treatment of deep seated brain tumors.
Young, Lori A.; Phillips, Mark H.; Cheung, Michael; Halasz, Lia M.; Rockhill, Jason K.
2017-01-01
Multisession stereotactic radiation therapy is increasingly being seen as a preferred option for intracranial diseases in close proximity to critical structures and for larger target volumes. The objective of this study is to investigate the reproducibility of the Extend system from Elekta. A retrospective review was conducted for all patients treated with multisession Gamma Knife between July 2010 and June 2015, including both malignant and benign lesions. Eighty-four patients were treated in this 5-year span. The average residual daily setup uncertainty was 0.48 (0.19) mm. We compare measurements of setup uncertainty from the Extend system to measurements performed with a linac-based approach previously used in our center. The Extend system has significantly reduced setup uncertainty for fractionated intracranial treatments at our institution. Positive results were observed in a small population of edentulous patients. The Extend system compares favorably with other approaches to delivering intracranial stereotactic radiotherapy and is a robust, simple-to-use, and precise method for treating multisession intracranial lesions. PMID:28514899
The Significance of Splenectomy in Experimental Swine Models of Controlled Hemorrhagic Shock
2013-11-01
carefully eval uated in other experimental models of hem orrhage (e.g., uncontrolled hemorrhage, models with concomitant blunt or orthopedic trauma , and...hemorrhagic shock. J Trauma . 2006;61(1):75 81. 3. Pottecher J, Chemla D, Xavier L, et al. The pulse pressure/heart rate ratio as a marker of stroke volume...changes during hemorrhagic shock and resuscitation in anesthetized swine. J Trauma Acute Care Surg. 2013;74(6):1438 1445. 4.Devlin JJ, Kircher SJ
Vingolo, Enzo Maria; Messano, Giuseppe Alessio; Fragiotta, Serena; Petti, Stefano
2015-01-01
Ebola virus disease (EVD—formerly known as Ebola hemorrhagic fever) is a severe hemorrhagic fever caused by lipid-enveloped, nonsegmented, negative-stranded RNA viruses belonging to the genus Ebolavirus. Case fatality rates may reach up to 76% of infected individuals, making this infection a deadly health problem in the sub-Saharan population. At the moment, there are still no indications on ophthalmological clinical signs and security suggestions for healthcare professionals (doctors and nurses or cooperative persons). This paper provides a short but complete guide to reduce infection risks. PMID:26557674
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wuthrick, Evan J., E-mail: evan.wuthrick@osumc.edu; Curran, Walter J.; Camphausen, Kevin
Purpose/Objective(s): Angiogenic blockade with irradiation may enhance the therapeutic ratio of radiation therapy (RT) through vascular normalization. We sought to determine the safety and toxicity profile of continuous daily-dosed sunitinib when combined with hypofractionated stereotactic RT (fSRT) for recurrent high-grade gliomas (rHGG). Methods and Materials: Eligible patients had malignant high-grade glioma that recurred or progressed after primary surgery and RT. All patients received a minimum of a 10-day course of fSRT, had World Health Organization performance status of 0 to 1, and a life expectancy of >3 months. During fSRT, sunitinib was administered at 37.5 mg daily. The primary endpoint was acutemore » toxicity, and response was assessed via serial magnetic resonance imaging. Results: Eleven patients with rHGG were enrolled. The fSRT doses delivered ranged from 30 to 42 Gy in 2.5- to 3.75-Gy fractions. The median follow-up time was 40 months. Common acute toxicities included hematologic disorders, fatigue, hypertension, and elevated liver transaminases. Sunitinib and fSRT were well tolerated. One grade 4 mucositis toxicity occurred, and no grade 4 or 5 hypertensive events or intracerebral hemorrhages occurred. One patient had a nearly complete response, and 4 patients had stable disease for >9 months. Two patients (18%) remain alive and progression-free >3 years from enrollment. The 6-month progression-free survival was 45%. Conclusions: Sunitinib at a daily dose of 37.5 mg given concurrently with hypofractionated stereotactic reirradiation for rHGG yields acceptable toxicities and an encouraging 6-month progression-free survival.« less
Small-volume resuscitation from hemorrhagic shock with polymerized human serum albumin.
Messmer, Catalina; Yalcin, Ozlem; Palmer, Andre F; Cabrales, Pedro
2012-10-01
Human serum albumin (HSA) is used as a plasma expander; however, albumin is readily eliminated from the intravascular space. The objective of this study was to establish the effects of various-sized polymerized HSAs (PolyHSAs) during small-volume resuscitation from hemorrhagic shock on systemic parameters, microvascular hemodynamics, and functional capillary density in the hamster window chamber model. Polymerized HSA size was controlled by varying the cross-link density (ie, molar ratio of glutaraldehyde to HSA). Hemorrhage was induced by controlled arterial bleeding of 50% of the animal's blood volume (BV), and hypovolemic shock was maintained for 1 hour. Resuscitation was implemented in 2 phases, first, by infusion of 3.5% of the BV of hypertonic saline (7.5% NaCl) then followed by infusion of 10% of the BV of each PolyHSA. Resuscitation provided rapid recovery of blood pressure, blood gas parameters, and microvascular perfusion. Polymerized HSA at a glutaraldehyde-to-HSA molar ratio of 60:1 (PolyHSA(60:1)) provided superior recovery of blood pressure, microvascular blood flow, and functional capillary density, and acid-base balance, with sustained volume expansion in relation to the volume infused. The high molecular weight of PolyHSA(60:1) increased the hydrodynamic radius and solution viscosity. Pharmacokinetic analysis of PolyHSA(60:1) indicates reduced clearance and increased circulatory half-life compared with monomeric HSA and other PolyHSA formulations. In conclusion, HSA molecular size and solution viscosity affect central hemodynamics, microvascular blood flow, volume expansion, and circulation persistence during small-volume resuscitation from hemorrhagic shock. In addition, PolyHSA can be an alternative to HSA in pathophysiological situations with compromised vascular permeability. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonier, Marcus, E-mail: Marcus.Sonier@bccancer.bc.ca; Chu, William; Department of Radiation Oncology, University of Toronto, Toronto, ON
To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotacticmore » body radiation therapy. Treatment time was reduced from 13.0 ± 2.6 to 4.0 ± 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 ± 0.39 to 1.12 ± 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 ± 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions.« less
CCR investigators are leading a trial of stereotactic body radiation therapy (SBRT) to treat localized prostate cancer that has recurred after standard radiation therapy. The technique uses advanced molecular imaging to guide the delivery of high doses of radiation just to tumors that have recurred, potentially leading to fewer side effects. Read more…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxim, Peter G.; Loo, Billy W.; Murphy, James D.
2011-11-15
Purpose: To evaluate the positioning accuracy of an optical positioning system for stereotactic radiosurgery in a pilot experience of optically guided, conventionally fractionated, radiotherapy for paranasal sinus and skull base tumors. Methods and Materials: Before each daily radiotherapy session, the positioning of 28 patients was set up using an optical positioning system. After this initial setup, the patients underwent standard on-board imaging that included daily orthogonal kilovoltage images and weekly cone beam computed tomography scans. Daily translational shifts were made after comparing the on-board images with the treatment planning computed tomography scans. These daily translational shifts represented the daily positionalmore » error in the optical tracking system and were recorded during the treatment course. For 13 patients treated with smaller fields, a three-degree of freedom (3DOF) head positioner was used for more accurate setup. Results: The mean positional error for the optically guided system in patients with and without the 3DOF head positioner was 1.4 {+-} 1.1 mm and 3.9 {+-} 1.6 mm, respectively (p <.0001). The mean positional error drifted 0.11 mm/wk upward during the treatment course for patients using the 3DOF head positioner (p = .057). No positional drift was observed in the patients without the 3DOF head positioner. Conclusion: Our initial clinical experience with optically guided head-and-neck fractionated radiotherapy was promising and demonstrated clinical feasibility. The optically guided setup was especially useful when used in conjunction with the 3DOF head positioner and when it was recalibrated to the shifts using the weekly portal images.« less
Ho, Allen L; Sussman, Eric S; Pendharkar, Arjun V; Le, Scheherazade; Mantovani, Alessandra; Keebaugh, Alaine C; Drover, David R; Grant, Gerald A; Wintermark, Max; Halpern, Casey H
2018-04-01
OBJECTIVE MR-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive method for thermal destruction of benign or malignant tissue that has been used for selective amygdalohippocampal ablation for the treatment of temporal lobe epilepsy. The authors report their initial experience adopting a real-time MRI-guided stereotactic platform that allows for completion of the entire procedure in the MRI suite. METHODS Between October 2014 and May 2016, 17 patients with mesial temporal sclerosis were selected by a multidisciplinary epilepsy board to undergo a selective amygdalohippocampal ablation for temporal lobe epilepsy using MRgLITT. The first 9 patients underwent standard laser ablation in 2 phases (operating room [OR] and MRI suite), whereas the next 8 patients underwent laser ablation entirely in the MRI suite with the ClearPoint platform. A checklist specific to the real-time MRI-guided laser amydalohippocampal ablation was developed and used for each case. For both cohorts, clinical and operative information, including average case times and accuracy data, was collected and analyzed. RESULTS There was a learning curve associated with using this real-time MRI-guided system. However, operative times decreased in a linear fashion, as did total anesthesia time. In fact, the total mean patient procedure time was less in the MRI cohort (362.8 ± 86.6 minutes) than in the OR cohort (456.9 ± 80.7 minutes). The mean anesthesia time was significantly shorter in the MRI cohort (327.2 ± 79.9 minutes) than in the OR cohort (435.8 ± 78.4 minutes, p = 0.02). CONCLUSIONS The real-time MRI platform for MRgLITT can be adopted in an expedient manner. Completion of MRgLITT entirely in the MRI suite may lead to significant advantages in procedural times.
Huang, Beilei; Xu, Qiusheng; Ye, Ru; Xu, Jun
2018-06-12
Tranexamic acid might be beneficial for cerebral hemorrhage. However, the results remained controversial. We conducted a systematic review and meta-analysis to explore the influence of tranexamic acid on cerebral hemorrhage. PubMed, EMbase, Web of science, EBSCO, and Cochrane library databases were systematically searched. Randomized controlled trials (RCTs) assessing the effect of tranexamic acid on cerebral hemorrhage were included. Two investigators independently searched articles, extracted data, and assessed the quality of included studies. This meta-analysis was performed using the random-effect model. Seven RCTs involving 1702 patients were included in the meta-analysis. Overall, compared with control intervention in cerebral hemorrhage, tranexamic acid could significantly reduce growth of hemorrhagic mass (RR = 0.78; 95% CI = 0.61-0.99; P = 0.04) and unfavorable outcome (RR = 0.75; 95% CI = 0.61-0.93; P = 0.008), but demonstrated no substantial influence on volume of hemorrhagic lesion (Std. MD = -0.10; 95% CI = -0.27 to 0.08; P = 0.28), neurologic deterioration (RR = 1.25; 95% CI = 0.60-2.60; P = 0.56), rebleeding (RR = 0.62; 95% CI = 0.35-1.09; P = 0.10), surgery requirement (RR = 0.78; 95% CI = 0.40-1.51; P = 0.46), and mortality (RR = 0.86; 95% CI = 0.69-1.05; P = 0.14). Compared to control intervention in cerebral hemorrhage, tranexamic acid was found to significantly decrease growth of hemorrhagic mass and unfavorable outcome, but showed no notable impact on volume of hemorrhagic lesion, neurologic deterioration, rebleeding, surgery requirement and mortality. Copyright © 2018 Elsevier B.V. All rights reserved.
Reisner, Andrew T; Edla, Shwetha; Liu, Jianbo; Rubin, John T; Thorsen, Jill E; Kittell, Erin; Smith, Jason B; Yeh, Daniel D; Reifman, Jaques
2016-03-01
During initial assessment of trauma patients, vital signs do not identify all patients with life-threatening hemorrhage. We hypothesized that a novel vital sign, muscle oxygen saturation (SmO2 ), could provide independent diagnostic information beyond routine vital signs for identification of hemorrhaging patients who require packed red blood cell (RBC) transfusion. This was an observational study of adult trauma patients treated at a Level I trauma center. Study staff placed the CareGuide 1100 tissue oximeter (Reflectance Medical Inc., Westborough, MA), and we analyzed average values of SmO2 , systolic blood pressure (sBP), pulse pressure (PP), and heart rate (HR) during 10 minutes of early emergency department evaluation. We excluded subjects without a full set of vital signs during the observation interval. The study outcome was hemorrhagic injury and RBC transfusion ≥ 3 units in 24 hours (24-hr RBC ≥ 3). To test the hypothesis that SmO2 added independent information beyond routine vital signs, we developed one logistic regression model with HR, sBP, and PP and one with SmO2 in addition to HR, sBP, and PP and compared their areas under receiver operating characteristic curves (ROC AUCs) using DeLong's test. We enrolled 487 subjects; 23 received 24-hr RBC ≥ 3. Compared to the model without SmO2 , the regression model with SmO2 had a significantly increased ROC AUC for the prediction of ≥ 3 units of 24-hr RBC volume, 0.85 (95% confidence interval [CI], 0.75-0.91) versus 0.77 (95% CI, 0.66-0.86; p < 0.05 per DeLong's test). Results were similar for ROC AUCs predicting patients (n = 11) receiving 24-hr RBC ≥ 9. SmO2 significantly improved the diagnostic association between initial vital signs and hemorrhagic injury with blood transfusion. This parameter may enhance the early identification of patients who require blood products for life-threatening hemorrhage. © 2016 The Authors. Academic Emergency Medicine published by Wiley Periodicals, Inc. on behalf of Society for Academic Emergency Medicine.
Robotically-adjustable microstereotactic frames for image-guided neurosurgery
NASA Astrophysics Data System (ADS)
Kratchman, Louis B.; Fitzpatrick, J. Michael
2013-03-01
Stereotactic frames are a standard tool for neurosurgical targeting, but are uncomfortable for patients and obstruct the surgical field. Microstereotactic frames are more comfortable for patients, provide better access to the surgical site, and have grown in popularity as an alternative to traditional stereotactic devices. However, clinically available microstereotactic frames require either lengthy manufacturing delays or expensive image guidance systems. We introduce a robotically-adjusted, disposable microstereotactic frame for deep brain stimulation surgery that eliminates the drawbacks of existing microstereotactic frames. Our frame can be automatically adjusted in the operating room using a preoperative plan in less than five minutes. A validation study on phantoms shows that our approach provides a target positioning error of 0.14 mm, which exceeds the required accuracy for deep brain stimulation surgery.
Hamm, Klaus D; Surber, Gunnar; Schmücking, Michael; Wurm, Reinhard E; Aschenbach, Rene; Kleinert, Gabriele; Niesen, A; Baum, Richard P
2004-11-01
Innovative new software solutions may enable image fusion to produce the desired data superposition for precise target definition and follow-up studies in radiosurgery/stereotactic radiotherapy in patients with intracranial lesions. The aim is to integrate the anatomical and functional information completely into the radiation treatment planning and to achieve an exact comparison for follow-up examinations. Special conditions and advantages of BrainLAB's fully automatic image fusion system are evaluated and described for this purpose. In 458 patients, the radiation treatment planning and some follow-up studies were performed using an automatic image fusion technique involving the use of different imaging modalities. Each fusion was visually checked and corrected as necessary. The computerized tomography (CT) scans for radiation treatment planning (slice thickness 1.25 mm), as well as stereotactic angiography for arteriovenous malformations, were acquired using head fixation with stereotactic arc or, in the case of stereotactic radiotherapy, with a relocatable stereotactic mask. Different magnetic resonance (MR) imaging sequences (T1, T2, and fluid-attenuated inversion-recovery images) and positron emission tomography (PET) scans were obtained without head fixation. Fusion results and the effects on radiation treatment planning and follow-up studies were analyzed. The precision level of the results of the automatic fusion depended primarily on the image quality, especially the slice thickness and the field homogeneity when using MR images, as well as on patient movement during data acquisition. Fully automated image fusion of different MR, CT, and PET studies was performed for each patient. Only in a few cases was it necessary to correct the fusion manually after visual evaluation. These corrections were minor and did not materially affect treatment planning. High-quality fusion of thin slices of a region of interest with a complete head data set could be performed easily. The target volume for radiation treatment planning could be accurately delineated using multimodal information provided by CT, MR, angiography, and PET studies. The fusion of follow-up image data sets yielded results that could be successfully compared and quantitatively evaluated. Depending on the quality of the originally acquired image, automated image fusion can be a very valuable tool, allowing for fast (approximately 1-2 minute) and precise fusion of all relevant data sets. Fused multimodality imaging improves the target volume definition for radiation treatment planning. High-quality follow-up image data sets should be acquired for image fusion to provide exactly comparable slices and volumetric results that will contribute to quality contol.
Dose-volume histogram prediction using density estimation.
Skarpman Munter, Johanna; Sjölund, Jens
2015-09-07
Knowledge of what dose-volume histograms can be expected for a previously unseen patient could increase consistency and quality in radiotherapy treatment planning. We propose a machine learning method that uses previous treatment plans to predict such dose-volume histograms. The key to the approach is the framing of dose-volume histograms in a probabilistic setting.The training consists of estimating, from the patients in the training set, the joint probability distribution of some predictive features and the dose. The joint distribution immediately provides an estimate of the conditional probability of the dose given the values of the predictive features. The prediction consists of estimating, from the new patient, the distribution of the predictive features and marginalizing the conditional probability from the training over this. Integrating the resulting probability distribution for the dose yields an estimate of the dose-volume histogram.To illustrate how the proposed method relates to previously proposed methods, we use the signed distance to the target boundary as a single predictive feature. As a proof-of-concept, we predicted dose-volume histograms for the brainstems of 22 acoustic schwannoma patients treated with stereotactic radiosurgery, and for the lungs of 9 lung cancer patients treated with stereotactic body radiation therapy. Comparing with two previous attempts at dose-volume histogram prediction we find that, given the same input data, the predictions are similar.In summary, we propose a method for dose-volume histogram prediction that exploits the intrinsic probabilistic properties of dose-volume histograms. We argue that the proposed method makes up for some deficiencies in previously proposed methods, thereby potentially increasing ease of use, flexibility and ability to perform well with small amounts of training data.
Behavior outcome after ischemic and hemorrhagic stroke, with similar brain damage, in rats.
Mestriner, Régis Gemerasca; Miguel, Patrícia Maidana; Bagatini, Pamela Brambilla; Saur, Lisiani; Boisserand, Lígia Simões Braga; Baptista, Pedro Porto Alegre; Xavier, Léder Leal; Netto, Carlos Alexandre
2013-05-01
Stroke causes disability and mortality worldwide and is divided into ischemic and hemorrhagic subtypes. Although clinical trials suggest distinct recovery profiles for ischemic and hemorrhagic events, this is not conclusive due to stroke heterogeneity. The aim of this study was to produce similar brain damage, using experimental models of ischemic (IS) and hemorrhagic (HS) stroke and evaluate the motor spontaneous recovery profile. We used 31 Wistar rats divided into the following groups: Sham (n=7), ischemic (IS) (n=12) or hemorrhagic (HS) (n=12). Brain ischemia or hemorrhage was induced by endotelin-1 (ET-1) and collagenase type IV-S (collagenase) microinjections, respectively. All groups were evaluated in the open field, cylinder and ladder walk behavioral tests at distinct time points as from baseline to 30 days post-surgery (30 PS). Histological and morphometric analyses were used to assess the volume of lost tissue and lesion length. Present results reveal that both forms of experimental stroke had a comparable long-term pattern of damage, since no differences were found in volume of tissue lost or lesion size 30 days after surgery. However, behavioral data showed that hemorrhagic rats were less impaired at skilled walking than ischemic ones at 15 and 30 days post-surgery. We suggest that experimentally comparable stroke design is useful because it reduces heterogeneity and facilitates the assessment of neurobiological differences related to stroke subtypes; and that spontaneous skilled walking recovery differs between experimental ischemic and hemorrhagic insults. Copyright © 2013 Elsevier B.V. All rights reserved.
Comprehensive approach to image-guided surgery
NASA Astrophysics Data System (ADS)
Peters, Terence M.; Comeau, Roch M.; Kasrai, Reza; St. Jean, Philippe; Clonda, Diego; Sinasac, M.; Audette, Michel A.; Fenster, Aaron
1998-06-01
Image-guided surgery has evolved over the past 15 years from stereotactic planning, where the surgeon planned approaches to intracranial targets on the basis of 2D images presented on a simple workstation, to the use of sophisticated multi- modality 3D image integration in the operating room, with guidance being provided by mechanically, optically or electro-magnetically tracked probes or microscopes. In addition, sophisticated procedures such as thalamotomies and pallidotomies to relieve the symptoms of Parkinson's disease, are performed with the aid of volumetric atlases integrated with the 3D image data. Operations that are performed stereotactically, that is to say via a small burr- hole in the skull, are able to assume that the information contained in the pre-operative imaging study, accurately represents the brain morphology during the surgical procedure. On the other hand, preforming a procedure via an open craniotomy presents a problem. Not only does tissue shift when the operation begins, even the act of opening the skull can cause significant shift of the brain tissue due to the relief of intra-cranial pressure, or the effect of drugs. Means of tracking and correcting such shifts from an important part of the work in the field of image-guided surgery today. One approach has ben through the development of intra-operative MRI imaging systems. We describe an alternative approach which integrates intra-operative ultrasound with pre-operative MRI to track such changes in tissue morphology.
Guo, Rui; Blacker, David J; Wang, Xia; Arima, Hisatomi; Lavados, Pablo M; Lindley, Richard I; Chalmers, John; Anderson, Craig S; Robinson, Thompson
2017-12-01
The prognosis in acute spontaneous intracerebral hemorrhage (ICH) is related to hematoma volume, where >30 mL is commonly used to define large ICH as a threshold for neurosurgical decompression but without clear supporting evidence. To determine the factors associated with large ICH and neurosurgical intervention among participants of the Intensive Blood Pressure Reduction in Acute Cerebral Hemorrhage Trials (INTERACT). We performed pooled analysis of the pilot INTERACT1 (n = 404) and main INTERACT2 (n = 2839) studies of ICH patients (<6 h of onset) with elevated systolic blood pressure (SBP, 150-220 mm Hg) who were randomized to intensive (target SBP < 140 mm Hg) or contemporaneous guideline-recommended (target SBP < 180 mm Hg) management. Neurosurgical intervention data were collected at 7 d postrandomization. Multivariable logistic regression was used to determine associations. There were 372 (13%) patients with large ICH volume (>30 mL), which was associated with nonresiding in China, nondiabetic status, severe neurological deficit (National Institutes of Health stroke scale [NIHSS] score ≥ 15), lobar location, intraventricular hemorrhage extension, raised leucocyte count, and hyponatremia. Significant predictors of those patients who underwent surgery (226 of 3233 patients overall; 83 of 372 patients with large ICH) were younger age, severe neurological deficit (lower Glasgow coma scale score, and NIHSS score ≥ 15), baseline ICH volume > 30 mL, and intraventricular hemorrhage. Early identification of severe ICH, based on age and clinical and imaging parameters, may facilitate neurosurgery and intensive monitoring of patients. Copyright © 2017 by the Congress of Neurological Surgeons
Treuer, Harald; Hoevels, Moritz; Luyken, Klaus; Visser-Vandewalle, Veerle; Wirths, Jochen; Kocher, Martin; Ruge, Maximilian
2015-06-01
Stereotactic radiosurgery with an adapted linear accelerator (linac-SRS) is an established therapy option for brain metastases, benign brain tumors, and arteriovenous malformations. We intended to investigate whether the dosimetric quality of treatment plans achieved with a CyberKnife (CK) is at least equivalent to that for linac-SRS with circular or micromultileaf collimators (microMLC). A random sample of 16 patients with 23 target volumes, previously treated with linac-SRS, was replanned with CK. Planning constraints were identical dose prescription and clinical applicability. In all cases uniform optimization scripts and inverse planning objectives were used. Plans were compared with respect to coverage, minimal dose within target volume, conformity index, and volume of brain tissue irradiated with ≥ 10 Gy. Generating the CK plan was unproblematic with simple optimization scripts in all cases. With the CK plans, coverage, minimal target volume dosage, and conformity index were significantly better, while no significant improvement could be shown regarding the 10 Gy volume. Multiobjective comparison for the irradiated target volumes was superior in the CK plan in 20 out of 23 cases and equivalent in 3 out of 23 cases. Multiobjective comparison for the treated patients was superior in the CK plan in all 16 cases. The results clearly demonstrate the superiority of the irradiation plan for CK compared to classical linac-SRS with circular collimators and microMLC. In particular, the average minimal target volume dose per patient, increased by 1.9 Gy, and at the same time a 14% better conformation index seems to be an improvement with clinical relevance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allibhai, Zishan; Taremi, Mojgan; Bezjak, Andrea
2013-12-01
Purpose: Stereotactic body radiation therapy for medically inoperable early-stage non-small cell lung cancer (NSCLC) offers excellent control rates. Most published series deal mainly with small (usually <4 cm), peripheral, solitary tumors. Larger tumors are associated with poorer outcomes (ie, lower control rates, higher toxicity) when treated with conventional RT. It is unclear whether SBRT is sufficiently potent to control these larger tumors. We therefore evaluated and examined the influence of tumor size on treatment outcomes after SBRT. Methods and Materials: Between October 2004 and October 2010, 185 medically inoperable patients with early (T1-T2N0M0) NSCLC were treated on a prospective researchmore » ethics board-approved single-institution protocol. Prescription doses were risk-adapted based on tumor size and location. Follow-up included prospective assessment of toxicity (as per Common Terminology Criteria for Adverse Events, version 3.0) and serial computed tomography scans. Patterns of failure, toxicity, and survival outcomes were calculated using Kaplan-Meier method, and the significance of tumor size (diameter, volume) with respect to patient, treatment, and tumor factors was tested. Results: Median follow-up was 15.2 months. Tumor size was not associated with local failure but was associated with regional failure (P=.011) and distant failure (P=.021). Poorer overall survival (P=.001), disease-free survival (P=.001), and cause-specific survival (P=.005) were also significantly associated with tumor size (with tumor volume more significant than diameter). Gross tumor volume and planning target volume were significantly associated with grade 2 or worse radiation pneumonitis. However, overall rates of grade ≥3 pneumonitis were low and not significantly affected by tumor or target size. Conclusions: Currently employed stereotactic body radiation therapy dose regimens can provide safe effective local therapy even for larger solitary NSCLC tumors (up to 5.7 cm in tumor diameter or 100 cm{sup 3} in tumor volume) but are associated with more nonlocal failures as well as poorer survival. These observations suggest these patients may benefit from more extensive staging or consideration of adjuvant therapy.« less
A GSK-3β Inhibitor Protects Against Radiation Necrosis in Mouse Brain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Xiaoyu; Perez-Torres, Carlos J.; Thotala, Dinesh
Purpose: To quantify the effectiveness of SB415286, a specific inhibitor of GSK-3β, as a neuroprotectant against radiation-induced central nervous system (brain) necrosis in a mouse model. Methods and Materials: Cohorts of mice were treated with SB415286 or dimethyl sulfoxide (DMSO) prior to irradiation with a single 45-Gy fraction targeted to the left hemisphere (brain) using a gamma knife machine. The onset and progression of radiation necrosis (RN) were monitored longitudinally by noninvasive in vivo small-animal magnetic resonance imaging (MRI) beginning 13 weeks postirradiation. MRI-derived necrotic volumes for SB415286- and DMSO-treated mice were compared. MRI results were supported by correlative histology. Results: Micemore » treated with SB415286 showed significant protection from radiation-induced necrosis, as determined by in vivo MRI with histologic validation. MRI-derived necrotic volumes were significantly smaller at all postirradiation time points in SB415286-treated animals. Although the irradiated hemispheres of the DMSO-treated mice demonstrated many of the classic histologic features of RN, including fibrinoid vascular necrosis, vascular telangiectasia, hemorrhage, and tissue loss, the irradiated hemispheres of the SB415286-treated mice consistently showed only minimal tissue damage. These studies confirmed that treatment with a GSK-3β inhibitor dramatically reduced delayed time-to-onset necrosis in irradiated brain. Conclusions: The unilateral cerebral hemispheric stereotactic radiation surgery mouse model in concert with longitudinal MRI monitoring provided a powerful platform for studying the onset and progression of RN and for developing and testing new neuroprotectants. Effectiveness of SB415286 as a neuroprotectant against necrosis motivates potential clinical trials of it or other GSK-3β inhibitors.« less
Kaakaji, W; Barnett, G H; Bernhard, D; Warbel, A; Valaitis, K; Stamp, S
2001-06-01
The goal of this study was to determine the clinical and economic consequences of early discharge (< 8 hours) of patients following stereotactic brain biopsy (SBB). The records of all patients who underwent percutaneous SBB at The Cleveland Clinic Foundation, a tertiary care teaching hospital, during 1994 and 1995 (Group A) were retrospectively reviewed to collect data on the nature and timing of perioperative (< 48 hours) clinical and radiological complications. Biopsies were performed using image-guided stereotaxy either with or without a frame. Based on the results, guidelines for early discharge of patients following SBB were implemented. Information on the nature and timing of perioperative complications was also collected prospectively in all patients who underwent percutaneous SBB from January 1996 through July 1998 (Group B). Hospital financial records for patients who underwent SBB in 1997 and 1998 were also reviewed and assessed for net revenue stratified by discharge status: early discharge (< 8 hours), extended outpatient observation (> or = 8 and < 24 hours). and inpatient hospitalization (> or = 24 hours). In Group A, 130 biopsies were performed. There were five serious complications (3.8%), of which four were transient, and there was one death (0.8%). The death and any sustained deficit occurred in patients in whom a clot had been demonstrated on postoperative CT scans. All complications were detected within 6 hours after surgery. Intraoperative bleeding occurred in 12 patients (9.2%), but was associated with only 40% of cases in which hemorrhage appeared on postoperative CT scans. Guidelines for early discharge (< 8 hours) following SBB were developed and stipulated the absence of the following: 1) intraoperative hemorrhage; 2) new postoperative deficit; and 3) clot on a postoperative CT scan. In Group B, 139 biopsies were performed. There were three serious complications (2.2%), one of which was sustained due to a clot that had been demonstrated on the postoperative CT scan. All complications were detected within 6 hours postsurgery. There were no deaths in this group. Intraoperative bleeding occurred in 11 patients (7.9%), requiring intraoperative craniotomy to control bleeding in one case. Hospital financial records were available for 96 patients, of whom 22 were discharged from the hospital early, 11 were observed for an extended outpatient period, and the remainder were retained for inpatient hospitalization. Average net hospital incomes on technical charges for patients in the inpatient hospitalization, extended outpatient observation, and short-stay (early discharge) groups were $1778, $1175, and $1219, respectively, in 1997, but declined to -$889, -$1339, and $671, respectively, in 1998. The ratios of indirect costs to direct technical costs were 132.5%, 128.7%, and 103.7%, respectively. Early discharge of patients following SBB of supratentorial lesions is safe in the absence of excessive intraoperative bleeding, new postoperative deficit, and clot on a postoperative CT scan. Extended outpatient observation (8-23 hours) is not clinically necessary and may be economically prohibitive in the setting of a teaching hospital.
Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula
2018-02-01
The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Microendoscopic stereotactic-guided percutaneous radiofrequency trigeminal nucleotractotomy.
Teixeira, Manoel Jacobsen; de Almeida, Fabrício Freitas; de Oliveira, Ywzhe Sifuentes Almeida; Fonoff, Erich Talamoni
2012-02-01
Over the past few decades, various authors have performed open or stereotactic trigeminal nucleotractotomy for the treatment of neuropathic facial pain resistant to medical treatment. Stereotactic procedures can be performed percutaneously under local anesthesia, allowing intraoperative neurological examination as a method for target refinement. However, blind percutaneous procedures in the region of the atlantooccipital transition carry a considerably high risk of vascular injuries that may bring prohibitive neurological deficit or even death. To avoid such complications, the authors present the first clinical use of microendoscopy to assist percutaneous radiofrequency trigeminal nucleotractotomy. The aim of this article is to demonstrate intradural microendoscopic visualization of the medulla oblongata through an atlantooccipital percutaneous approach. The authors present a case of severe postherpetic facial neuralgia in a patient who underwent the procedure and had satisfactory results. Stereotactic computational image planning for targeting the spinal trigeminal tract and nucleus in the posterolateral medulla was performed, allowing for an accurate percutaneous approach. Immediately before radiofrequency electrode insertion, a fine endoscope was introduced to visualize the structures in the cisterna magna. Microendoscopic visualization offered clear identification of the pial surface of the medulla oblongata and its blood vessels, the arachnoid membrane, cranial nerve rootlets and their entry zone, and larger vessels such as the vertebral arteries and the branches of the posterior inferior cerebellar artery. The initial application of this technique suggests that percutaneous microendoscopy may be useful for particular manipulation of the medulla oblongata, increasing the safety of the procedure and likely improving its effectiveness.
Multiple brain metastases irradiation with Eleka Axesse stereotactic system
NASA Astrophysics Data System (ADS)
Filatov, P. V.; Polovnikov, E. S.; Orlov, K. Yu.; Krutko, A. V.; Kirilova, I. A.; Moskalev, A. V.; Filatova, E. V.; Zheravin, A. A.
2017-09-01
Brain metastases are one of the factors complicating the treatment of a malignant tumor. Radiation therapy, especially radiosurgery, plays an important role in the modern treatment practice. During 2011-2016, 32 patients (from 29 to 67 years old) with multiple brain metastases underwent the treatment with SRS or SRT in our center. The number of secondary lesions varied from 2 to 11. Eight patients underwent microsurgery resection. Seven patients had recurrence after whole brain radiotherapy. Thirty patient underwent single fraction SRS and two patients with large metastases (bigger than 3 cm) underwent fractionated SRT. The treatment was done with dedicated linear accelerator stereotactic system Elekta Axesse (Elekta AB, Stockholm, Sweden). Different stereotactic fixation devices were used, namely, Leksell G frame, non-invasive HeadFIX frame, and reinforced thermoplastic mask (IMRT perforation). All treatments included a volumetric modulated arc therapy (VMAT) technique and of Inage Guided Radiation Therapy (IGRT) technique. All lesions were treated from a single isocenter, which allowed reducing the treatment time and overall dose to the patient's body. All patients suffered the treatment satisfactorily. No adverse reactions or complications were met in any case during or right after the treatment. Different stereotactic fixation devices and modern treatment techniques allowed creating an optimal, safe and comfortable way for patient treatment. The treatment time was from 15 to 50 minutes. Patient position verification after or during the treatment demonstrated good accuracy for all fixation types and low level of intrafraction motion.
Tam, Emily W.Y.; Miller, Steven P.; Studholme, Colin; Chau, Vann; Glidden, David; Poskitt, Kenneth J.; Ferriero, Donna M.; Barkovich, A. James
2010-01-01
Objective To hypothesize that detailed examination of early cerebellar volumes over time would distinguish differences in cerebellar growth associated with intraventricular hemorrhage (IVH) and white matter injury (WMI) in preterm infants. Study design Preterm newborns at the University of California San Francisco (n=57) and the University of British Columbia (n=115) were studied using serial MRI scans near birth and again at near term-equivalent age. Interactive semi-automated tools were used to determine volumes of the cerebellar hemispheres. Results Adjusting for supratentorial brain injury, cerebellar hemorrhage, and study site, cerebellar volume increased 1.7cm3/week postmenstrual age (95% CI 1.6–1.7, P<0.001). More severe supratentorial IVH was associated with slower growth of cerebellar volumes (P<0.001). Volumes by 40 weeks were 1.4 cm3 lower in premature infants with grade 1–2 IVH and 5.4 cm3 lower with grade 3–4 IVH. The same magnitude of decrease was found between ipsilateral and contralateral IVH. No association was found with severity of WMI (P=0.3). Conclusions Early effects of decreased cerebellar volume associated with supratentorial IVH in either hemisphere may be a result of concurrent cerebellar injury or direct effects of subarachnoid blood on cerebellar development. PMID:20961562
Zhong, Jian-Hua; Zhou, Hua-Jun; Tang, Tao; Cui, Han-Jin; Yang, A-Li; Zhang, Qi-Mei; Zhou, Jing-Hua; Zhang, Qiang; Gong, Xun; Zhang, Zhao-Hui; Mei, Zhi-Gang
2017-10-27
OBJECTIVE Reactive astrogliosis, a key feature that is characterized by glial proliferation, has been observed in rat brains after intracerebral hemorrhage (ICH). However, the mechanisms that control reactive astrogliosis formation remain unknown. Notch-1 signaling plays a critical role in modulating reactive astrogliosis. The purpose of this paper was to establish whether Notch-1 signaling is involved in reactive astrogliosis after ICH. METHODS ICH was induced in adult male Sprague-Dawley rats via stereotactic injection of autologous blood into the right globus pallidus. N-[ N-(3,5-difluorophenacetyl)-l-alanyl]- S-phenylglycine t-butyl ester (DAPT) was injected into the lateral ventricle to block Notch-1 signaling. The rats' brains were perfused to identify proliferating cell nuclear antigen (PCNA)-positive/GFAP-positive nuclei. The expression of GFAP, Notch-1, and the activated form of Notch-1 (Notch intracellular domain [NICD]) and its ligand Jagged-1 was assessed using immunohistochemical and Western blot analyses, respectively. RESULTS Notch-1 signaling was upregulated and activated after ICH as confirmed by an increase in the expression of Notch-1 and NICD and its ligand Jagged-1. Remarkably, blockade of Notch-1 signaling with the specific inhibitor DAPT suppressed astrocytic proliferation and GFAP levels caused by ICH. In addition, DAPT improved neurological outcome after ICH. CONCLUSIONS Notch-1 signaling is a critical regulator of ICH-induced reactive astrogliosis, and its blockage may be a potential therapeutic strategy for hemorrhagic injury.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pinkham, D.W.; Shultz, D.; Loo, B.W.
Purpose: The advent of electromagnetic navigation bronchoscopy has enabled minimally invasive access to peripheral lung tumors previously inaccessible by optical bronchoscopes. As an adjunct to Stereotactic Ablative Radiosurgery (SABR), implantation of HDR catheters can provide focal treatments for multiple metastases and sites of retreatments. The authors evaluate a procedure to deliver ablative doses via Electromagnetically-Guided HDR (EMG-HDR) to lung metastases, quantify the resulting dosimetry, and assess its role in the comprehensive treatment of lung cancer. Methods: A retrospective study was conducted on ten patients, who, from 2009 to 2011, received a hypo-fractionated SABR regimen with 6MV VMAT to lesions inmore » various lobes ranging from 1.5 to 20 cc in volume. A CT visible pathway was delineated for EM guided placement of an HDR applicator (catheter) and dwell times were optimized to ensure at least 98% prescription dose coverage of the GTV. Normal tissue doses were calculated using inhomogeneity corrections via a grid-based Boltzmann solver (Acuros-BV-1.5.0). Results: With EMG-HDR, an average of 83% (+/−9% standard deviation) of each patient’s GTV received over 200% of the prescription dose, as compared to SABR where the patients received an average maximum dose of 125% (+/−5%). EMG-HDR enabled a 59% (+/−12%) decrease in the aorta maximum dose, a 63% (+/−26%) decrease in the spinal cord max dose, and 57% (+/−23%) and 70% (+/−17%) decreases in the volume of the body receiving over 50% and 25% of the prescription dose, respectively. Conclusion: EMG-HDR enables delivery of higher ablative doses to the GTV, while concurrently reducing surrounding normal tissue doses. The single catheter approach shown here is limited to targets smaller than 20 cc. As such, the technique enables ablation of small lesions and a potentially safe and effective retreatment option in situations where external beam utility is limited by normal tissue constraints.« less
Evaluation of image-guided helical tomotherapy for the retreatment of spinal metastasis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahan, Stephen L.; Ramsey, Chester R.; Scaperoth, Daniel D.
Introduction: Patients with vertebral metastasis that receive radiation therapy are typically treated to the spinal cord tolerance dose. As such, it is difficult to successfully deliver a second course of radiation therapy for patients with overlapping treatment volumes. In this study, an image-guided helical tomotherapy system was evaluated for the retreatment of previously irradiated vertebral metastasis. Methods and Materials: Helical tomotherapy dose gradients and maximum cord doses were measured in a cylindrical phantom for geometric test cases with separations between the planning target volume (PTV) and the spinal cord organ at risk (OAR) of 2 mm, 4 mm, 6 mm,more » 8 mm, and 10 mm. Megavoltage computed tomography (CT) images were examined for their ability to localize spinal anatomy for positioning purposes by repeat imaging of the cervical spine in an anthropomorphic phantom. In addition to the phantom studies, 8 patients with cord compressions that had received previous radiation therapy were retreated to a mean dose of 28 Gy using conventional fractionation. Results and Discussion: Megavoltage CT images were capable of positioning an anthropomorphic phantom to within {+-}1.2 mm (2{sigma}) superior-inferiorly and within {+-}0.6 mm (2{sigma}) anterior-posteriorly and laterally. Dose gradients of 10% per mm were measured in phantom while PTV uniformity indices of less than 11% were maintained. The calculated maximum cord dose was 25% of the prescribed dose for a 10-mm PTV-to-OAR separation and 71% of the prescribed dose for a PTV-to-OAR separation of 2 mm. Eight patients total have been treated without radiation-induced myelopathy or any other adverse effects from treatment. Conclusions: A technique has been evaluated for the retreatment of vertebral metastasis using image-guided helical tomotherapy. Phantom and patient studies indicated that a tomotherapy system is capable of delivering dose gradients of 10% per mm and positioning the patient within 1.2 mm without the use of special stereotactic immobilization.« less
Ueyama, Tomoko; Arimura, Takeshi; Takumi, Koji; Nakamura, Fumihiko; Higashi, Ryutaro; Ito, Soichiro; Fukukura, Yoshihiko; Umanodan, Tomokazu; Nakajo, Masanori; Koriyama, Chihaya; Yoshiura, Takashi
2018-06-01
To identify risk factors for symptomatic radiation pneumonitis (RP) after stereotactic radiation therapy (SRT) for lung tumours. We retrospectively evaluated 68 lung tumours in 63 patients treated with SRT between 2011 and 2015. RP was graded according to the National Cancer Institute-Common Terminology Criteria for Adverse Events version 4.0. SRT was delivered at 7.0-12.0 Gy per each fraction, once daily, to a total of 48-64 Gy (median, 50 Gy). Univariate analysis was performed to assess patient- and treatment-related factors, including age, sex, smoking index (SI), pulmonary function, tumour location, serum Krebs von den Lungen-6 value (KL-6), dose-volume metrics (V5, V10, V20, V30, V40 and VS5), homogeneity index of the planning target volume (PTV), PTV dose, mean lung dose (MLD), contralateral MLD and V2, PTV volume, lung volume and the PTV/lung volume ratio (PTV/Lung). Performance of PTV/Lung in predicting symptomatic RP was also analysed using receiver operating characteristic (ROC) analysis. The median follow-up period was 21 months. 10 of 63 patients (15.9%) developed symptomatic RP after SRT. On univariate analysis, V10, V20, PTV volume and PTV/Lung were significantly associated with occurrence of RP ≥Grade 2. ROC curves indicated that symptomatic RP could be predicted using PTV/Lung [area under curve (AUC): 0.88, confidence interval (CI: 0.78-0.95), cut-off value: 1.09, sensitivity: 90.0% and specificity: 72.4%]. PTV/Lung is a good predictor of symptomatic RP after SRT. Advances in knowledge: The cases with high PTV/Lung should be carefully monitored with caution for the occurrence of RP after SRT.
Kiesel, Barbara; Millesi, Matthias; Woehrer, Adelheid; Furtner, Julia; Bavand, Anahita; Roetzer, Thomas; Mischkulnig, Mario; Wolfsberger, Stefan; Preusser, Matthias; Knosp, Engelbert; Widhalm, Georg
2018-06-01
OBJECTIVE Stereotactic needle biopsies are usually performed for histopathological confirmation of intracranial lymphomas to guide adequate treatment. During biopsy, intraoperative histopathology is an effective tool to avoid acquisition of nondiagnostic samples. In the last years, 5-aminolevulinic acid (5-ALA)-induced fluorescence has been increasingly used for visualization of diagnostic brain tumor tissue during stereotactic biopsies. Recently, visible fluorescence was reported in the first cases of intracranial lymphomas as well. The aim of this study is thus to investigate the technical and clinical utility of 5-ALA-induced fluorescence in a large series of stereotactic biopsies for intracranial lymphoma. METHODS This prospective study recruited adult patients who underwent frameless stereotactic needle biopsy for a radiologically suspected intracranial lymphoma after oral 5-ALA administration. During biopsy, samples from the tumor region were collected for histopathological analysis, and presence of fluorescence (strong, vague, or no fluorescence) was assessed with a modified neurosurgical microscope. In tumors with available biopsy samples from at least 2 different regions the intratumoral fluorescence homogeneity was additionally investigated. Furthermore, the influence of potential preoperative corticosteroid treatment or immunosuppression on fluorescence was analyzed. Histopathological tumor diagnosis was established and all collected biopsy samples were screened for diagnostic lymphoma tissue. RESULTS The final study cohort included 41 patients with intracranial lymphoma. Stereotactic biopsies with assistance of 5-ALA were technically feasible in all cases. Strong fluorescence was found as maximum level in 30 patients (75%), vague fluorescence in 2 patients (4%), and no visible fluorescence in 9 patients (21%). In 28 cases, samples were obtained from at least 2 different tumor regions; homogenous intratumoral fluorescence was found in 16 of those cases (57%) and inhomogeneous intratumoral fluorescence in 12 (43%). According to histopathological analysis, all samples with strong or vague fluorescence contained diagnostic lymphoma tissue, resulting in a positive predictive value of 100%. Analysis showed no influence of preoperative corticosteroids or immunosuppression on fluorescence. CONCLUSIONS The data obtained in this study demonstrate the technical and clinical utility of 5-ALA-induced fluorescence in stereotactic biopsies of intracranial lymphomas. Thus, 5-ALA can serve as a useful tool to select patients not requiring intraoperative histopathology, and its application should markedly reduce operation time and related costs in the future.
Servat, Juan J; Elia, Maxwell Dominic; Gong, Dan; Manes, R Peter; Black, Evan H; Levin, Flora
2014-12-01
To assess the feasibility of routine use of electromagnetic image guidance systems in orbital decompression. Six consecutive patients underwent stereotactic-guided three wall orbital decompression using the novel Fusion ENT Navigation System (Medtronic), a portable and expandable electromagnetic guidance system with multi-instrument tracking capabilities. The system consists of the Medtronic LandmarX System software-enabled computer station, signal generator, field-generating magnet, head-mounted marker coil, and surgical tracking instruments. In preparation for use of the LandmarX/Fusion protocol, all patients underwent preoperative non-contrast CT scan from the superior aspect of the frontal sinuses to the inferior aspect of the maxillary sinuses that includes the nasal tip. The Fusion ENT Navigation System (Medtronic™) was used in 6 patients undergoing maximal 3-wall orbital decompression for Graves' orbitopthy after a minimum of six months of disease inactivity. Preoperative Hertel exophthalmometry measured more than 27 mm in all patients. The navigation system proved to be no more difficult technically than the traditional orbital decompression approach. Electromagnetic image guidance is a stereotactic surgical navigation system that provides additional intraoperative flexibility in orbital surgery. Electromagnetic image-guidance offers the ability to perform more aggressive orbital decompressions with reduced risk.
Cao, Minsong; Raldow, Ann C; Dang, Audrey; Lamb, James; Low, Daniel A; Steinberg, Michael L.; Lee, Percy
2018-01-01
We present a case of durable local control achieved in a patient treated with stereotactic magnetic resonance-guided adaptive radiation therapy (SMART) for an abdominal lymph node in the setting of oligometastatic breast cancer. A 50-year-old woman with a history of triple positive metastatic invasive ductal carcinoma of the left breast, stage IV (T3N2M1), underwent neoadjuvant chemotherapy, mastectomy, adjuvant radiotherapy and maintenance hormonal treatment with HER2 targeted therapies. At 20 months after definitive treatment of her primary, imaging showed an isolated progressive enlargement of lymph nodes between hepatic segment V/IVB and the neck of the pancreas. Radiofrequency ablation was considered, however, this approach was decided not to be optimal due to the proximity to stomach, and pancreatic duct. The patient was treated with SMART for 40 Gray in 5 fractions. Two and a half years later, the patient remains without evidence of disease progression. She experienced Grade 2 acute and late toxicity that was successfully managed with medications. This experience shows that SMART is a feasible and effective treatment to control the abdominal oligometastatic disease for breast cancer. PMID:29805937
Ohtakara, Kazuhiro; Hoshi, Hiroaki
2014-06-01
To determine the preliminary clinical outcomes of image-guided 3-dimensional conformal radiotherapy (IG-3DCRT) for limited but variably-sized brain metastases (BM). Sixty-two lesions in 24 patients were retrospectively evaluated; out of these patients 75% were ≥ 65 years of age, and 37.5% were categorized into recursive partitioning analysis (RPA) class 3. The median value for the maximum diameter of the lesions was 19 mm (range=4-72 mm). The median sole treatment dose was 36 Gy in 10 fractions. The median survival durations after IG-3DCRT were 12.0 months and 3.2 months for patients categorized into RPA classes ≤ 2 and 3, respectively. Local recurrences occurred in two lesions with a 6-month local control probability of 93.0%. Major toxicities included radiation necrosis in two patients. IG-3DCRT is feasible even for patients with limited BM who are categorized into RPA class 3, and confers clinical outcomes comparable to those of stereotactic radiosurgery, including excellent local control and minimal toxicity even for large tumors. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Stereotactic CO2 laser therapy for hydrocephalus
NASA Astrophysics Data System (ADS)
Kozodoy-Pins, Rebecca L.; Harrington, James A.; Zazanis, George A.; Nosko, Michael G.; Lehman, Richard M.
1994-05-01
A new fiber-optic delivery system for CO2 radiation has been used to successfully treat non-communicating hydrocephalus. This system consists of a hollow sapphire waveguide employed in the lumen of a stereotactically-guided neuroendoscope. CO2 gas flows through the bore of the hollow waveguide, creating a path for the laser beam through the cerebrospinal fluid (CSF). This delivery system has the advantages of both visualization and guided CO2 laser radiation without the same 4.3 mm diameter scope. Several patients with hydrocephalus were treated with this new system. The laser was used to create a passage in the floor of the ventricle to allow the flow of CSF from the ventricles to the sub-arachnoid space. Initial postoperative results demonstrated a relief of the clinical symptoms. Long-term results will indicate if this type of therapy will be superior to the use of implanted silicone shunts. Since CO2 laser radiation at 10.6 micrometers is strongly absorbed by the water in tissue and CSF, damage to tissue surrounding the lesion with each laser pulse is limited. The accuracy and safety of this technique may prove it to be an advantageous therapy for obstructive hydrocephalus.
The Evaluation and Management of Adult Intracerebral Hemorrhage.
Cai, Xuemei; Rosand, Jonathan
2015-12-01
Intracerebral hemorrhage (ICH) is the most disabling and deadly form of stroke. Although mortality remains high, new data suggest that outcomes can be improved with standardized medical care. In this review, the authors outline the most up-to-date knowledge, including the results of the latest phase III clinical trials on the specialized care needed to treat patients with ICH. They provide an overview on how to achieve rapid diagnosis and the initial steps of intervention to reduce hematoma volume or prevent expansion by modifying potentially treatable conditions, such as underlying vascular etiologies, blood pressure control, and coagulopathies. Grading scales can help identify patients at risk for hematoma expansion and functional disabilities and guide clinical decision making. Other medical management topics important to recovery and prevention of secondary brain injury include seizure prevention and treatment, glycemic control, temperature control, and deep venous thrombosis prophylaxis and treatment. Treatment options in surgery are also possible in select patients; there are emerging studies regarding minimally invasive surgery for the management of ICH. These aggressive therapies are essential to lower the morbidity and mortality of patients presenting with ICH. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Godoy, Daniel Agustin; Piñero, Gustavo Rene; Koller, Patricia; Masotti, Luca; Di Napoli, Mario
2015-01-01
Spontaneous intracerebral hemorrhage is a type of stroke associated with poor outcomes. Mortality is elevated, especially in the acute phase. From a pathophysiological point of view the bleeding must traverse different stages dominated by the possibility of re-bleeding, edema, intracranial hypertension, inflammation and neurotoxicity due to blood degradation products, mainly hemoglobin and thrombin. Neurological deterioration and death are common in early hours, so it is a true neurological-neurosurgical emergency. Time is brain so that action should be taken fast and accurately. The most significant prognostic factors are level of consciousness, location, volume and ventricular extension of the bleeding. Nihilism and early withdrawal of active therapy undoubtedly influence the final result. Although there are no proven therapeutic measures, treatment should be individualized and guided preferably by pathophysiology. The multidisciplinary teamwork is essential. Results of recently completed studies have birth to promising new strategies. For correct management it’s important to establish an orderly and systematic strategy based on clinical stabilization, evaluation and establishment of prognosis, avoiding secondary insults and adoption of specific individualized therapies, including hemostatic therapy and intensive control of elevated blood pressure. Uncertainty continues regarding the role of surgery. PMID:26261773
NASA Astrophysics Data System (ADS)
Kron, T.; Ungureanu, E.; Antony, R.; Hardcastle, N.; Clements, N.; Ukath, J.; Fox, C.; Lonski, P.; Wanigaratne, D.; Haworth, A.
2017-01-01
Stereotactic Ablative Body Radiotherapy (SABR) is an extension of the concepts of Stereotactic Radiosurgery from intracranial procedures to extracranial targets. This brings with it new technological challenges for set-up of a SABR program and continuing quality assurance. Compared with intracranial procedures SABR requires consideration of motion and inhomogeneities and has to deal with a much larger variety of targets ranging from lung to liver, kidney and bone. To meet many of the challenges virtually all advances in modern radiotherapy, such as Intensity Modulated and Image Guided Radiation Therapy (IMRT and IGRT) are used. Considering the few fractions and high doses per fraction delivered to complex targets it is not surprising that patient specific quality control is considered essential for safe delivery. Given the variety of targets and clinical scenarios we employ different strategies for different patients to ensure that the most important aspects of the treatment are appropriately tested, be it steep dose gradients, inhomogeneities or the delivery of dose in the presence of motion. The current paper reviews the different approaches and phantoms utilised at Peter MacCallum Cancer Centre for SABR QA.
Meretoja, Atte; Churilov, Leonid; Campbell, Bruce C V; Aviv, Richard I; Yassi, Nawaf; Barras, Christen; Mitchell, Peter; Yan, Bernard; Nandurkar, Harshal; Bladin, Christopher; Wijeratne, Tissa; Spratt, Neil J; Jannes, Jim; Sturm, Jonathan; Rupasinghe, Jayantha; Zavala, Jorge; Lee, Andrew; Kleinig, Timothy; Markus, Romesh; Delcourt, Candice; Mahant, Neil; Parsons, Mark W; Levi, Christopher; Anderson, Craig S; Donnan, Geoffrey A; Davis, Stephen M
2014-06-01
No evidence-based acute therapies exist for intracerebral hemorrhage. Intracerebral hemorrhage growth is an important determinant of patient outcome. Tranexamic acid is known to reduce hemorrhage in other conditions. The study aims to test the hypothesis that intracerebral hemorrhage patients selected with computed tomography angiography contrast extravasation 'spot sign' will have lower rates of hematoma growth when treated with intravenous tranexamic acid within 4.5-hours of stroke onset compared with placebo. The Spot sign and Tranexamic acid On Preventing ICH growth--AUStralasia Trial is a multicenter, prospective, 1:1 randomized, double-blind, placebo-controlled, investigator-initiated, academic Phase II trial. Intracerebral hemorrhage patients fulfilling clinical criteria (e.g. Glasgow Coma Scale >7, intracerebral hemorrhage volume <70 ml, no identified secondary cause of intracerebral hemorrhage, no thrombotic events within the previous 12 months, no planned surgery) and demonstrating contrast extravasation on computed tomography angiography will receive either intravenous tranexamic acid 1 g 10-min bolus followed by 1 g eight-hour infusion or placebo. A second computed tomography will be performed at 24 ± 3 hours to evaluate intracerebral hemorrhage growth and patients followed up for three-months. The primary outcome measure is presence of intracerebral hemorrhage growth by 24 ± 3 hours, defined as either >33% or >6 ml increase from baseline, and will be adjusted for baseline intracerebral hemorrhage volume. Secondary outcome measures include growth as a continuous measure, thromboembolic events, and the three-month modified Rankin Scale score. This is the first trial to evaluate the efficacy of tranexamic acid in intracerebral hemorrhage patients selected based on an imaging biomarker of high likelihood of hematoma growth. The trial is registered as NCT01702636. © 2013 The Authors. International Journal of Stroke © 2013 World Stroke Organization.
Merna, Catherine; Rwigema, Jean-Claude M; Cao, Minsong; Wang, Pin-Chieh; Kishan, Amar U; Michailian, Argin; Lamb, James; Sheng, Ke; Agazaryan, Nzhde; Low, Daniel A; Kupelian, Patrick; Steinberg, Michael L; Lee, Percy
2016-01-01
We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non-small cell lung cancer with a tri-cobalt-60 (tri-(60)Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)-based SBRT. In all, 20 patients with large central early-stage non-small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-(60)Co system for a prescription dose of 50Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R100 values were calculated as the total tissue volume receiving 100% of the dose (V100) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-(60)Co SBRT plans were performed using Student׳s t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3cc (range: 12.1 to 139.4cc). Of the tri-(60)Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R100 values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-(60)Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-(60)Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while improving normal tissue sparing, which warrants further investigation in a prospective feasibility clinical trial. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merna, Catherine; Rwigema, Jean-Claude M.; Cao, Minsong
We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non−small cell lung cancer with a tri-cobalt-60 (tri-{sup 60}Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)–based SBRT. In all, 20 patients with large central early-stage non−small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-{sup 60}Co system for a prescription dose of 50 Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R{sub 100} values were calculatedmore » as the total tissue volume receiving 100% of the dose (V{sub 100}) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-{sup 60}Co SBRT plans were performed using Student's t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3 cc (range: 12.1 to 139.4 cc). Of the tri-{sup 60}Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R{sub 100} values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-{sup 60}Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-{sup 60}Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while improving normal tissue sparing, which warrants further investigation in a prospective feasibility clinical trial.« less
Stereotactic radiotherapy for malignancies involving the trigeminal and facial nerves.
Cuneo, K C; Zagar, T M; Brizel, D M; Yoo, D S; Hoang, J K; Chang, Z; Wang, Z; Yin, F F; Das, S K; Green, S; Ready, N; Bhatti, M T; Kaylie, D M; Becker, A; Sampson, J H; Kirkpatrick, J P
2012-06-01
Involvement of a cranial nerve caries a poor prognosis for many malignancies. Recurrent or residual disease in the trigeminal or facial nerve after primary therapy poses a challenge due to the location of the nerve in the skull base, the proximity to the brain, brainstem, cavernous sinus, and optic apparatus and the resulting complex geometry. Surgical resection caries a high risk of morbidity and is often not an option for these patients. Stereotactic radiosurgery and radiotherapy are potential treatment options for patients with cancer involving the trigeminal or facial nerve. These techniques can deliver high doses of radiation to complex volumes while sparing adjacent critical structures. In the current study, seven cases of cancer involving the trigeminal or facial nerve are presented. These patients had unresectable recurrent or residual disease after definitive local therapy. Each patient was treated with stereotactic radiation therapy using a linear accelerator based system. A multidisciplinary approach including neuroradiology and surgical oncology was used to delineate target volumes. Treatment was well tolerated with no acute grade 3 or higher toxicity. One patient who was reirradiated experienced cerebral radionecrosis with mild symptoms. Four of the seven patients treated had no evidence of disease after a median follow up of 12 months (range 2-24 months). A dosimetric analysis was performed to compare intensity modulated fractionated stereotactic radiation therapy (IM-FSRT) to a 3D conformal technique. The dose to 90% (D90) of the brainstem was lower with the IM-FSRT plan by a mean of 13.5 Gy. The D95 to the ipsilateral optic nerve was also reduced with IM-FSRT by 12.2 Gy and the D95 for the optic chiasm was lower with FSRT by 16.3 Gy. Treatment of malignancies involving a cranial nerve requires a multidisciplinary approach. Use of an IM-FSRT technique with a micro-multileaf collimator resulted in a lower dose to the brainstem, optic nerves and chiasm for each case examined.
SU-E-T-56: Brain Metastasis Treatment Plans for Contrast-Enhanced Synchrotron Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Obeid, L; Adam, J; Tessier, A
2014-06-01
Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The aim of this study is to compare dynamic stereotactic arc-therapy and iodineenhanced SSRT. Methods: Five patients bearing brain metastasis received a standard helical 3D-scan without iodine. A second scan was acquired 13 min after an 80 g iodine infusion. Two SSRT treatment plans (with/without iodine) were performed for each patient using a dedicated Monte Carlo (MC) treatment planning system (TPS) based on the ISOgray TPS. Ten coplanar beams (6×6 cm2, shaped with collimator)more » were simulated. MC statistical error objective was less than 5% in the 50% isodose. The dynamic arc-therapy plan was achieved on the Iplan Brainlab TPS. The treatment plan validation criteria were fixed such that 100% of the prescribed dose is delivered at the beam isocentre and the 70% isodose contains the whole target volume. The comparison elements were the 70% isodose volume, the average and maximum doses delivered to organs at risk (OAR): brainstem, optical nerves, chiasma, eyes, skull bone and healthy brain parenchyma. Results: The stereotactic dynamic arc-therapy remains the best technique in terms of dose conformation. Iodine-enhanced SSRT presents similar performances to dynamic arc-therapy with increased brainstem and brain parenchyma sparing. One disadvantage of SSRT is the high dose to the skull bone. Iodine accumulation in metastasis may increase the dose by 20–30%, allowing a normal tissue sparing effect at constant prescribed dose. Treatment without any iodine enhancement (medium-energy stereotactic radiotherapy) is not relevant with degraded HDVs (brain, parenchyma and skull bone) comparing to stereotactic dynamic arc-therapy. Conclusion: Iodine-enhanced SSRT exhibits a good potential for brain metastasis treatment regarding the dose distribution and OAR criteria.« less
Fetomaternal hemorrhage during external cephalic version.
Boucher, Marc; Marquette, Gerald P; Varin, Jocelyne; Champagne, Josette; Bujold, Emmanuel
2008-07-01
To estimate the frequency and volume of fetomaternal hemorrhage during external cephalic version for term breech singleton fetuses and to identify risk factors involved with this complication. A prospective observational study was performed including all patients undergoing a trial of external cephalic version for a breech presentation of at least 36 weeks of gestation between 1987 and 2001 in our center. A search for fetal erythrocytes using the standard Kleihauer-Betke test was obtained before and after each external cephalic version. The frequency and volume of fetomaternal hemorrhage were calculated. Putative risk factors for fetomaternal hemorrhage were evaluated by chi(2) test and Mann-Whitney U test. A Kleihauer-Betke test result was available before and after 1,311 trials of external cephalic version. The Kleihauer-Betke test was positive in 67 (5.1%) before the procedure. Of the 1,244 women with a negative Kleihauer-Betke test before external cephalic version, 30 (2.4%) had a positive Kleihauer-Betke test after the procedure. Ten (0.8%) had an estimated fetomaternal hemorrhage greater than 1 mL, and one (0.08%) had an estimated fetomaternal hemorrhage greater than 30 mL. The risk of fetomaternal hemorrhage was not influenced by parity, gestational age, body mass index, number of attempts at version, placental location, or amniotic fluid index. The risk of detectable fetomaternal hemorrhage during external cephalic version was 2.4%, with fetomaternal hemorrhage more than 30 mL in less than 0.1% of cases. These data suggest that the performance of a Kleihauer-Betke test is unwarranted in uneventful external cephalic version and that in Rh-negative women, no further Rh immune globulin is necessary other than the routine 300-microgram dose at 28 weeks of gestation and postpartum. II.
Marsh, Elisabeth B; Llinas, Rafael H; Schneider, Andrea L C; Hillis, Argye E; Lawrence, Erin; Dziedzic, Peter; Gottesman, Rebecca F
2016-01-01
Hemorrhagic transformation (HT) increases the morbidity and mortality of ischemic stroke. Anticoagulation is often indicated in patients with atrial fibrillation, low ejection fraction, or mechanical valves who are hospitalized with acute stroke, but increases the risk of HT. Risk quantification would be useful. Prior studies have investigated risk of systemic hemorrhage in anticoagulated patients, but none looked specifically at HT. In our previously published work, age, infarct volume, and estimated glomerular filtration rate (eGFR) significantly predicted HT. We created the hemorrhage risk stratification (HeRS) score based on regression coefficients in multivariable modeling and now determine its validity in a prospectively followed inpatient cohort.A total of 241 consecutive patients presenting to 2 academic stroke centers with acute ischemic stroke and an indication for anticoagulation over a 2.75-year period were included. Neuroimaging was evaluated for infarct volume and HT. Hemorrhages were classified as symptomatic versus asymptomatic, and by severity. HeRS scores were calculated for each patient and compared to actual hemorrhage status using receiver operating curve analysis.Area under the curve (AUC) comparing predicted odds of hemorrhage (HeRS score) to actual hemorrhage status was 0.701. Serum glucose (P < 0.001), white blood cell count (P < 0.001), and warfarin use prior to admission (P = 0.002) were also associated with HT in the validation cohort. With these variables, AUC improved to 0.854. Anticoagulation did not significantly increase HT; but with higher intensity anticoagulation, hemorrhages were more likely to be symptomatic and more severe.The HeRS score is a valid predictor of HT in patients with ischemic stroke and indication for anticoagulation.
Bradac, Ondrej; Steklacova, Anna; Nebrenska, Katerina; Vrana, Jiri; de Lacy, Patricia; Benes, Vladimir
2017-08-01
Frameless stereotactic brain biopsy systems are widely used today. VarioGuide (VG) is a relatively novel frameless system. Its accuracy was studied in a laboratory setting but has not yet been studied in the clinical setting. The purpose of this study was to determine its accuracy and diagnostic yield and to compare this with frame-based (FB) stereotaxy. Overall, 53 patients (33 males and 20 females, 60 ± 15 years old) were enrolled into this prospective, randomized, single-center study. Twenty-six patients were randomized into the FB group and 27 patients into the VG group. Real trajectory was pointed on intraoperative magnetic resonance. The distance of the targets and angle deviation between the planned and real trajectories were computed. The overall discomfort of the patient was subjectively assessed by the visual analog scale score. The median lesion volume was 5 mL (interquartile range [IQR]: 2-16 mL) (FB) and 16 mL (IQR: 2-27 mL) (VG), P = 0.133. The mean distance of the targets was 2.7 ± 1.1 mm (FB) and 2.9 ± 1.3 mm (VG), P = 0.456. Mean angle deviation was 2.6 ± 1.3 deg (FB) and 3.5 ± 2.1 deg (VG), P = 0.074. Diagnostic yield was 93% (25/27) in VG and 96% (25/26) in FB, P = 1.000. Mean operating time was 47 ± 26 minutes (FB) and 59 ± 31 minutes (VG), P = 0.140. One minor bleeding was encountered in the VG group. Overall patient discomfort was significantly higher in the FB group (visual analog scale score 2.5 ± 2.1 vs. 1.2 ± 0.6, P = 0,004). The VG system proved to be comparable in terms of the trajectory accuracy, rate of complications and diagnostic yield compared with the "gold standard" represented by the traditional FB stereotaxy for patients undergoing brain biopsy. VG is also better accepted by patients. Copyright © 2017 Elsevier Inc. All rights reserved.
Intensity-based 2D 3D registration for lead localization in robot guided deep brain stimulation
NASA Astrophysics Data System (ADS)
Hunsche, Stefan; Sauner, Dieter; El Majdoub, Faycal; Neudorfer, Clemens; Poggenborg, Jörg; Goßmann, Axel; Maarouf, Mohammad
2017-03-01
Intraoperative assessment of lead localization has become a standard procedure during deep brain stimulation surgery in many centers, allowing immediate verification of targeting accuracy and, if necessary, adjustment of the trajectory. The most suitable imaging modality to determine lead positioning, however, remains controversially discussed. Current approaches entail the implementation of computed tomography and magnetic resonance imaging. In the present study, we adopted the technique of intensity-based 2D 3D registration that is commonly employed in stereotactic radiotherapy and spinal surgery. For this purpose, intraoperatively acquired 2D x-ray images were fused with preoperative 3D computed tomography (CT) data to verify lead placement during stereotactic robot assisted surgery. Accuracy of lead localization determined from 2D 3D registration was compared to conventional 3D 3D registration in a subsequent patient study. The mean Euclidian distance of lead coordinates estimated from intensity-based 2D 3D registration versus flat-panel detector CT 3D 3D registration was 0.7 mm ± 0.2 mm. Maximum values of these distances amounted to 1.2 mm. To further investigate 2D 3D registration a simulation study was conducted, challenging two observers to visually assess artificially generated 2D 3D registration errors. 95% of deviation simulations, which were visually assessed as sufficient, had a registration error below 0.7 mm. In conclusion, 2D 3D intensity-based registration revealed high accuracy and reliability during robot guided stereotactic neurosurgery and holds great potential as a low dose, cost effective means for intraoperative lead localization.
2013-08-01
in central blood volume similar to hemorrhage in humans. Lower-body negative- pressure (LBNP) is a unique physiologic model that has been adopted to...relatively high tolerance (HT) to reduced blood volume, while 30% to 35% display low toler- ance (LT), with earlier onset of cardiovascular instability (i.e... pressure were recorded by infrared finger photoplethysmography (Finometer Blood Pressure Mon- itor, TNO-TPD Biomedical Instrumentation, Amsterdam
Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT.
Thomas, David H; Santhanam, Anand; Kishan, Amar U; Cao, Minsong; Lamb, James; Min, Yugang; O'Connell, Dylan; Yang, Yingli; Agazaryan, Nzhde; Lee, Percy; Low, Daniel
2018-02-01
To evaluate variations in intra- and interfractional tumour motion, and the effect on internal target volume (ITV) contour accuracy, using deformable image registration of real-time two-dimensional-sagittal cine-mode MRI acquired during lung stereotactic body radiation therapy (SBRT) treatments. Five lung tumour patients underwent free-breathing SBRT treatments on the ViewRay system, with dose prescribed to a planning target volume (defined as a 3-6 mm expansion of the 4DCT-ITV). Sagittal slice cine-MR images (3.5 × 3.5 mm 2 pixels) were acquired through the centre of the tumour at 4 frames per second throughout the treatments (3-4 fractions of 21-32 min). Tumour gross tumour volumes (GTVs) were contoured on the first frame of the MR cine and tracked for the first 20 min of each treatment using offline optical-flow based deformable registration implemented on a GPU cluster. A ground truth ITV (MR-ITV 20 min ) was formed by taking the union of tracked GTV contours. Pseudo-ITVs were generated from unions of the GTV contours tracked over 10 s segments of image data (MR-ITV 10 s ). Differences were observed in the magnitude of median tumour displacement between days of treatments. MR-ITV 10 s areas were as small as 46% of the MR-ITV 20 min . An ITV offers a "snapshot" of breathing motion for the brief period of time the tumour is imaged on a specific day. Real-time MRI over prolonged periods of time and over multiple treatment fractions shows that ITV size varies. Further work is required to investigate the dosimetric effect of these results. Advances in knowledge: Five lung tumour patients underwent free-breathing MRI-guided SBRT treatments, and their tumours tracked using deformable registration of cine-mode MRI. The results indicate that variability of both intra- and interfractional breathing amplitude should be taken into account during planning of lung radiotherapy.
Snider, James W; Mutaf, Yildirim; Nichols, Elizabeth; Hall, Andrea; Vadnais, Patrick; Regine, William F; Feigenberg, Steven J
2017-01-01
Partial-breast irradiation (PBI) with external-beam radiotherapy has produced higher than expected rates of fair-to-poor cosmesis. Worsened outcomes have been correlated with larger volumes of breast tissue exposed to radiation. A novel breast-specific stereotactic radiotherapy (BSRT) device (BSRTD) has been developed at our institution and has shown promise in delivering highly conformal dose distributions. We compared normal tissue sparing with this device with that achieved with intensity-modulated radiation therapy (IMRT)-PBI. Fifteen women previously treated with breast conservation therapy were enrolled on an institutional review board-approved protocol. Each of them underwent CT simulation in the prone position using the BSRTD-specific immobilization system. Simulated postoperative and preoperative treatment volumes were generated based on surgical bed/clip position. Blinded planners generated IMRT-PBI plans and BSRT plans for each set of volumes. These plans were compared based on clinically validated markers for cosmetic outcome and toxicity using a Wilcoxon rank-sum test. The BSRT plans consistently reduced the volumes receiving each of several dose levels (Vx) to breast tissue, the chest wall, the lung, the heart, and the skin in both preoperative and postoperative settings (p < 0.05). Preoperative BSRT yielded particularly dramatic improvements. The novel BSRTD has demonstrated significant dosimetric benefits over IMRT-PBI. Further investigation is currently proceeding through initial clinical trials. © 2016 S. Karger AG, Basel.
Autologous blood transfusion in dogs with thoracic or abdominal hemorrhage: 25 cases (2007-2012).
Higgs, Veronica A; Rudloff, Elke; Kirby, Rebecca; Linklater, Andrew K J
2015-01-01
To describe the use and outcome following autologous blood transfusion (ABT) in dogs. Retrospective study (January 2007-July 2012). Private veterinary referral center. Twenty-five dogs that underwent ABT secondary to thoracic or abdominal hemorrhage. None. The hospital transaction database was searched using the keyword "autotransfusion" from January 2007 to July 2012. Data collected included signalment, body weight, etiology of hemorrhage, source and method of collection, volumes and method of ABT administration, use of anticoagulant, reported complications, and outcome. Twenty-five dogs were included for a total of 27 ABTs. Causes of hemorrhage included vascular trauma (14/25 dogs, 56%), ruptured tumor (8/25, 32%), and coagulopathy attributed to brodifacoum toxicosis (3/25, 12%). Autologous blood was collected from the abdominal (19/25, 76%), thoracic (5/25, 20%), or abdominal and thoracic cavities (1/25, 4%). Anticoagulant was added to the ABT blood in 13 of 25 (52%) cases. A median ABT volume of 29.3 mL/kg (range 2.9-406.9 mL/kg) was infused through either a 210 μm blood administration filter (21/27, 78%) or an 18 μm hemonate filter (6/27, 22%). Reported complications that may have been associated with ABT included hypocalcemia (4/17, 24%), hemolyzed serum (5/19, 26%), and prolonged coagulation times (4/5, 80%). These complications were considered of minimal clinical significance. Additional blood products were administered in 17 of 25 (68%) dogs. Seventeen (68%) dogs survived to discharge. Cause of death in the remaining cases was euthanasia or cardiac arrest secondary to uncontrollable hemorrhage. ABT is an adjunct to volume replacement in dogs with thoracic or abdominal hemorrhage secondary to vascular trauma, ruptured tumor, or anticoagulant rodenticide toxicosis. ABT may be used as bridge to definitive hemorrhage control, particularly when other blood products are not available or affordable. Complications may include hypocalcemia, prolonged coagulation times, and hemolysis. © Veterinary Emergency and Critical Care Society 2015.
How large is the typical subarachnoid hemorrhage? A review of current neurosurgical knowledge.
Whitmore, Robert G; Grant, Ryan A; LeRoux, Peter; El-Falaki, Omar; Stein, Sherman C
2012-01-01
Despite the morbidity and mortality of subarachnoid hemorrhage (SAH), the average volume of a typical hemorrhage is not well defined. Animal models of SAH often do not accurately mimic the human disease process. The purpose of this study is to estimate the average SAH volume, allowing standardization of animal models of the disease. We performed a MEDLINE search of SAH volume and erythrocyte counts in human cerebrospinal fluid as well as for volumes of blood used in animal injection models of SAH, from 1956 to 2010. We polled members of the American Association of Neurological Surgeons (AANS) for estimates of typical SAH volume. Using quantitative data from the literature, we calculated the total volume of SAH as equal to the volume of blood clotted in basal cisterns plus the volume of dispersed blood in cerebrospinal fluid. The results of the AANS poll confirmed our estimates. The human literature yielded 322 publications and animal literature, 237 studies. Four quantitative human studies reported blood clot volumes ranging from 0.2 to 170 mL, with a mean of ∼20 mL. There was only one quantitative study reporting cerebrospinal fluid red blood cell counts from serial lumbar puncture after SAH. Dispersed blood volume ranged from 2.9 to 45.9 mL, and we used the mean of 15 mL for our calculation. Therefore, total volume of SAH equals 35 mL. The AANS poll yielded 176 responses, ranging from 2 to 350 mL, with a mean of 33.9 ± 4.4 mL. Based on our estimate of total SAH volume of 35 mL, animal injection models may now become standardized for more accurate portrayal of the human disease process. Copyright © 2012 Elsevier Inc. All rights reserved.
2016-01-01
deficit hyperactivity disorder . The above diagram illustrates the time to death from admission from a retrospective review of 1,029 deaths over 4 years...hypotension occurring as consequences of the primary insult. TBI also predicts the development of both post-traumatic stress disorder and attention ...special attention to the management of hemorrhage on the battlefield” [Bellamy, 1984 #2647]. Despite extraordinary advances in hemorrhage control [Butler
2017-06-12
REBOA.Methods: 12 swine were anesthetized, instrumented, then underwent 15 blood volume hemorrhage. Animals were randomized to hypothermia or...normothermia followed by 4 hours of zone III REBOA, resuscitation with shed blood , and 3 hours of critical care. Physiologic parameters were continuously...significant differences between groups at baseline or after hemorrhage. No histologic differences were observed in hind limb skeletal muscle. Maximum
Pleural liquid during hemorrhagic hypotension.
Tresoldi, Claudio; Porta, Cristina; Zocchi, Luciano; Agostoni, Emilio
2007-02-15
The effect of approximately 25% or 35% blood loss (b.l.) on volume, pressure, and protein concentration of pleural liquid has been determined in anesthetized rabbits in lateral or supine posture. Volume and pressure of pleural liquid did not change with 25% b.l. 30 and 60 min after beginning of hemorrhage, and with 35% b.l. at 30 min (bleeding time approximately 10 and 12 min, respectively). With 35% b.l. protein concentration of pleural liquid was 85% greater (P<0.01) than control; moreover, percent albumin was smaller (P<0.05), and percent globulin greater (P<0.05) than control. Decrease in arterial plasma protein concentration, hematocrit, and pH after hemorrhage fit literature data. Ventilation at 15 and 30 min increased (P<0.01) by 16% and 23%, respectively, with 25% b.l., but it did not change with 35% b.l., a condition borderline to survival in anesthetized rabbits without ad hoc treatment. Pleural liquid seems protected against derangements from hemorrhage up to 25% b.l. for periods shorter than 1 h.
Rock, Jack P; Ryu, Samuel; Yin, Fang-Fang; Schreiber, Faye; Abdulhak, Muwaffak
2004-01-01
Traditional management strategies for patients with spinal tumors have undergone considerable changes during the last 15 years. Significant improvements in digital imaging, computer processing, and treatment planning have provided the basis for the application of stereotactic techniques, now the standard of care for intracranial pathology, to spinal pathology. In addition, certain of these improvements have also allowed us to progress from frame-based to frameless systems which now act to accurately assure the delivery of high doses of radiation to a precisely defined target volume while sparing injury to adjacent normal tissues. In this article we will describe the evolution from yesterday's standards for radiation therapy to the current state of the art for the treatment of patients with spinal tumors. This presentation will include a discussion of radiation dosing and toxicity, the overall process of extracranial radiation delivery, and the current state of the art regarding Cyberknife, Novalis, and tomotherapy. Additional discussion relating current research protocols and future directions for the management of benign tumors of the spine will also be presented.
Transperineal prostate biopsy with ECHO-MRI fusion. Biopsee system. Initial experience.
Romero-Selas, E; Cuadros, V; Montáns, J; Sánchez, E; López-Alcorocho, J M; Gómez-Sancha, F
2016-06-01
The aim of this study is to present our initial experience with the stereotactic echo-MRI fusion system for diagnosing prostate cancer. Between September 2014 and January 2015, we performed 50 prostate biopsies using the stereotactic echo-MRI fusion system. The 3-Tesla multiparameter MR images were superimposed using this image fusion system on 3D echo images obtained with the Biopsee system for the exact locating of areas suspected of prostate cancer. The lesions were classified using the Prostate Imaging Report and Date System. We assessed a total of 50 patients, with a mean age of 63 years (range, 45-79), a mean prostate-specific antigen level of 8 ng/mL (range, 1.9-20) and a mean prostate volume of 52mL (range, 12-118). Prostate cancer was diagnosed in 69% of the patients and intraepithelial neoplasia in 6%. The results of the biopsy were negative for 24% of the patients. The results of the biopsy and MRI were in agreement for 62% of the patients; however, 46% also had a tumour outside of the suspicious lesion. We diagnosed 46% anterior tumours and 33% apical tumours. One patient had a haematuria, another had a haematoma and a third had acute urine retention. Multiparametric prostatic MRI helps identify prostate lesions suggestive of cancer. The Biopsee echo-MRI fusion system provides for guided biopsy and increases the diagnostic performance, reducing the false negatives of classical biopsies and increasing the diagnosis of anterior tumours. Transperineal access minimises the risk of prostatic infection and sepsis. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widmann, Gerlig, E-mail: gerlig.widmann@i-med.ac.at; Schullian, Peter, E-mail: peter.schullian@i-med.ac.at; Haidu, Marion, E-mail: marion.haidu@i-med.ac.at
Purpose: To evaluate technique effectiveness, safety, and interoperator performance of stereotactic radiofrequency ablation (SRFA) of liver lesions. Methods: Retrospective review including 90 consecutive patients from January 2008 to January 2010 with 106 computed tomography-guided SRFA sessions using both single and multiple electrodes for the treatment of 177 lesions: 72 hepatocellular carcinoma (HCC) and 105 metastases with a mean size of 2.9 cm (range 0.5-11 cm). Technique effectiveness and 1-year local recurrence were evaluated by computed tomographic scans. Complications, mortality, and hospital days were recorded. The performance between an experienced and inexperienced interventional radiologist was compared. Results: The overall technique effectivenessmore » after a single SRFA was 95.5% (93.1% for HCC and 97.1% for metastases). Four of the eight unsuccessfully treated lesions could be retreated (secondary technique effectiveness of 97.7%). Local recurrence at 1 year was 2.9%. Technique effectiveness was significantly different for lesions <5 cm (96.7%) and >5 cm (87.5%) (P = 0.044) but not for lesions <3 cm (95.9%) and 3-5 cm (100%). Compared to clear parenchymal property (97.3%), vessel vicinity (93.3%) (P = 0.349) and subcapsular (95.2%) (P = 0.532) had no, but hollow viscera vicinity (83.3%) had a significantly lower technique effectiveness (P = 0.020). Mortality rate was 0.9%. Major complications and hospital days were higher for cirrhosis Child-Pugh B (20%, 7.2 days) than Child-Pugh A (3.1%, 4.7 days) patients and for metastases (5.1%, 4.3 days). There was no significant difference in interoperator performance. Conclusions: RFA allowed for efficient, reliable, and safe ablation of large-volume liver disease.« less
Giske, Kristina; Stoiber, Eva M; Schwarz, Michael; Stoll, Armin; Muenter, Marc W; Timke, Carmen; Roeder, Falk; Debus, Juergen; Huber, Peter E; Thieke, Christian; Bendl, Rolf
2011-06-01
To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kunos, Charles A., E-mail: charles.kunos@UHhospitals.org; Debernardo, Robert; Radivoyevitch, Tomas
Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile,more » 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.« less
Frank, Leslie Smith; Frank, James L; March, David; Makari-Judson, Grace; Barham, Ruth B; Mertens, Wilson C
2007-01-01
To determine whether therapeutic touch administered at the time of stereotactic core biopsy of suspicious breast lesions results in a reduction in anxiety and pain. Randomized, patient-blinded, controlled trial of either Krieger-Kunz therapeutic touch administered by a trained practitioner or a sham intervention mimicking therapeutic touch delivered during core biopsy. Stereotactic breast biopsy unit of a comprehensive breast center. Women with mammographically detected, nonpalpable breast lesions requiring biopsy. Changes in pain and anxiety measured by visual analog scales immediately before and after stereotactic core biopsy. A total of 82 patients were accrued: 42 received actual therapeutic touch and 40 sham therapeutic touch. No significant differences were found between the arms for age, ethnicity, educational background, or other demographic data. The sham arm had a preponderance of left breast biopsies (48% vs 58%; P = 0.07) and received a slightly higher volume of epinephrine-containing local anesthetic (6.5 +/- 6.1 vs 4.5 +/- 4.5 mL; P = 0.09). Therapeutic touch patients were more likely to have an upper breast lesion location (57% vs 53%; P = 0.022). No significant differences between the arms were seen regarding postbiopsy pain (P = 0.95), anxiety (P = 0.66), fearfulness, or physiological parameters. Similarly, no differences were seen between the arms when change in parameters from prebiopsy to postbiopsy was considered for any of the psychological or physiological variables measured. These findings persisted when confounding variables were controlled for. Women undergoing stereotactic core breast biopsy received no significant benefit from therapeutic touch administered during the procedure. Therapeutic touch cannot be routinely recommended for patients in this setting.
Small intracerebral hemorrhages have a low spot sign prevalence and are less likely to expand.
Dowlatshahi, Dar; Yogendrakumar, Vignan; Aviv, Richard I; Rodriguez-Luna, David; Molina, Carlos A; Silva, Yolanda; Dzialowski, Imanuel; Czlonkowska, Anna; Boulanger, Jean-Martin; Lum, Cheemun; Gubitz, Gord; Padma, Vasantha; Roy, Jayanta; Kase, Carlos S; Bhatia, Rohit; Hill, Michael D; Demchuk, Andrew M
2016-02-01
Hematoma expansion is a major predictor of morbidity and mortality after intracerebral hemorrhage (ICH). Both baseline hematoma volume and the CT-angiogram (CTA) spot sign predict hematoma expansion. Because the CTA spot sign may represent foci of active hemorrhage, we hypothesized that patients with smaller baseline hematoma volumes are less likely to be spot sign positive, and therefore less likely to expand. We sought to validate our prior finding that small hematomas are unlikely to expand, and to determine the relationship between baseline hematoma volume, spot sign status, and risk of hematoma expansion. Data were from the prospective PREDICT ICH study. Patients presenting within 6 h of symptom onset with completed baseline CT, CTA, and follow-up CT were included. Baseline hematoma volume was categorized a priori (<3 mL, 3-10 mL, 10-20 mL, >20 mL). The primary outcome was significant hematoma expansion (≥6 mL, ≥12.5 mL or ≥33%) and secondary outcomes were early neurological worsening, good clinical outcome (modified Rankin Scale 0-3), and mortality at 90 days. Among 315 patients meeting the inclusion criteria, baseline hematoma volume category predicted absolute hematoma expansion (p < 0.001), spot sign prevalence (p < 0.001), early neurologic worsening (p = 0.002), clinical outcome (p < 0.001), and mortality (p < 0.001). Very small hematomas (<3 mL) were unlikely to be spot positive (7.7%), unlikely to expand (2.6%), and were associated with a 73% chance of good clinical outcome. Spot sign appeared to be most predictive of expansion in the 3-10 mL baseline hematoma volume category. Very small hematomas are unlikely to expand and have a low spot sign prevalence. Hemostatic therapy trials may be best targeted at hemorrhages >3 mL in volume. © 2016 World Stroke Organization.
Yadav, Vivek R.; Sahoo, Kaustuv; Roberts, Pamela R.
2013-01-01
An exaggerated release of proinflammatory cytokines and accompanying inflammation contributes to the development of multiple organ failure after hemorrhagic shock. Here, we tested the nuclear factor (NF) κ-light-chain-enhancer of activated B cell (NF-κB)–mediated transcriptional control of inflammatory pathways as a target in the management of hemorrhage-induced inflammation. We performed a study in a rat model of fixed-volume hemorrhage to investigate the anti-inflammatory effects of the diphenyldifluoroketone EF24 [3,5-bis(2-fluorobenzylidene)piperidin-4-one], an NF-κB inhibitor, in lung tissue. EF24 treatment (0.4 mg/kg) significantly prevented the upregulation of inflammatory biomarkers in rats subjected to 50% hemorrhage and preserved the pulmonary histology in hemorrhaged rats. The lung tissue from treated rats showed marked suppression of the hemorrhage-mediated induction of Toll-like receptor 4, phospho-p65 NF-κB, inducible nitric-oxide synthase, heme oxygenase–1, and cyclooxygenase-2 (COX-2). The hemorrhage-induced COX-2 activity was also significantly inhibited by the EF24 treatment. At the same time, EF24 induced nuclear factor (erythroid-derived 2)-like 2–mediated protective mechanisms against oxidative stress. EF24 also reduced hemorrhage-induced lung myeloperoxidase activity. The plasma levels of proinflammatory tumor necrosis factor-α, interleukin (IL)-6, IL-1α, and IL-1β were lower in EF24-treated rats than in untreated rats. Moreover, there was a significant reduction in the pulmonary expression of high-mobility group B1 protein. These biochemical effects were accompanied by a significant improvement in the survival of rats administered with EF24 as compared with the rats receiving vehicle control (P < 0.05). Overall, the results suggest that EF24 attenuates hemorrhage-induced inflammation and could serve as a salutary anti-inflammatory agent in resuscitation strategies. PMID:23995597
do Nascimento, Paulo; Vaid, Sumreen U; Hoskins, Stephen L; Espana, Jonathan M; Kinsky, Michael P; Kramer, George C
2007-05-01
Initial fluid resuscitation of hemorrhagic shock might be enhanced by the infusion of monocarboxylate-energy substrates. We evaluated hemodynamics, metabolism, and fluid dynamics for initial resuscitation of hemorrhage using small volume 15% sodium pyruvate solution (HPY) compared with osmotically matched 8% hypertonic saline (HS). Instrumented conscious sheep were hemorrhaged 25 mL/kg at time zero through 15 min (T0-T15) and 5 mL/kg for 5 min at T50 to T55 and T70 to T75. Fluid resuscitation from T30 to T180 was performed by a computer-controlled closed-loop system, which titrated infusion rate to a mean arterial pressure of 90 mmHg. Initial infusion was 4 mL/kg of either HPY or HS, followed by the administration of lactated Ringer. Both HPY and HS restored cardiac index similarly. The lactate/pyruvate ratio was used to assess metabolic debt and was significantly higher (T180), whereas oxygen delivery was significantly lower (T120) with HPY versus HS. Total fluid administered was similar, with 43.7 +/- 6.2 mL/kg for HPY and 39.4 +/- 6.8 mL/kg for HS. Plasma volume was similarly increased and approached baseline values for both groups. Initial resuscitation with small volume HPY offered no hemodynamic or metabolic advantage compared with small volume HS when the fluids were infused to an end point pressure.
Under Pressure: Intraluminal Filling Pressures of Postpartum Hemorrhage Tamponade Balloons
Antony, Kathleen M.; Racusin, Diana A.; Belfort, Michael A.; Dildy, Gary A.
2017-01-01
Objective Uterine tamponade by fluid-filled balloons is now an accepted method of controlling postpartum hemorrhage. Available tamponade balloons vary in design and material, which affects the filling attributes and volume at which they rupture. We aimed to characterize the filling capacity and pressure-volume relationship of various tamponade balloons. Study Design Balloons were filled with water ex vivo. Intraluminal pressure was measured incrementally (every 10 mL for the Foley balloons and every 50 mL for all other balloons). Balloons were filled until they ruptured or until 5,000 mL was reached. Results The Foley balloons had higher intraluminal pressures than the larger-volume balloons. The intraluminal pressure of the Sengstaken-Blakemore tube (gastric balloon) was initially high, but it decreased until shortly before rupture occurred. The Bakri intraluminal pressure steadily increased until rupture occurred at 2,850 mL. The condom catheter, BT-Cath, and ebb all had low intraluminal pressures. Both the BT-Cath and the ebb remained unruptured at 5,000 mL. Conclusion In the setting of acute hemorrhage, expeditious management is critical. Balloons that have a low intraluminal pressure-volume ratio may fill more rapidly, more easily, and to greater volumes. We found that the BT-Cath, the ebb, and the condom catheter all had low intraluminal pressures throughout filling. PMID:28497006
2008-06-01
Bpops,[ a dose of 90 Hg kgj1 will produce serum concentrations of factor VII high enough to reduce hemorrhage by accelerating thrombin production and...interaction is species-specific, and human FVII seems to have only between 5% and 50% activity when exposed to porcine tissue factor (15). The results...Copyright @ 200 by the Shock Society. Unauthorized reproduction of this article is prohibited.8 RECOMBINANT FACTOR VIIA REDUCES REBLEED HEMORRHAGE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Chengyu, E-mail: shicy1974@yahoo.com; Chen, Yong; Fang, Deborah
2015-04-01
Liver stereotactic body radiation therapy (SBRT) is a feasible treatment method for the nonoperable, patient with early-stage liver cancer. Treatment planning for the SBRT is very important and has to consider the simulation accuracy, planning time, treatment efficiency effects etc. The modified dynamic conformal arc (MDCA) technique is a 3-dimensional conformal arc planning method, which has been proposed for liver SBRT planning at our center. In this study, we compared the MDCA technique with the RapidArc technique in terms of planning target volume (PTV) coverage and sparing of organs at risk (OARs). The results show that the MDCA technique hasmore » comparable plan quality to RapidArc considering PTV coverage, hot spots, heterogeneity index, and effective liver volume. For the 5 PTVs studied among 4 patients, the MDCA plan, when compared with the RapidArc plan, showed 9% more hot spots, more heterogeneity effect, more sparing of OARs, and lower liver effective volume. The monitor unit (MU) number for the MDCA plan is much lower than for the RapidArc plans. The MDCA plan has the advantages of less planning time, no-collision treatment, and a lower MU number.« less
Ge, Shunnan; Chang, Chongwang; Adler, John R; Zhao, Haikang; Chang, Xiaozan; Gao, Li; Wu, Heming; Wang, Jing; Li, Nan; Wang, Xuelian; Gao, Guodong
2013-01-01
To investigate the long-term outcome and changes of the personality and psychopathological profile of opiate addicts after bilateral stereotactic nucleus accumbens (NAc) ablative surgery. 60 patients were followed up for 5 years and abstinent status and adverse events were evaluated. NAc lesion volumes and locations were obtained by postoperative MRI scans. The Chinese version of the Eysenck Personality Questionnaire (EPQ-RSC), the Symptom Checklist-90-Revised (SCL-90-R), the Beck Depression Inventory (BDI), the Yale-Brown Obsessive Compulsive Scale (Y-BOCS) and the World Health Organization's Quality of Life Questionnaire - Brief Version (WHOQOL-BREF) were administered to the patients before and 5 years after the stereotactic surgery. The total abstinence rate of all patients in their 5th postoperative year was 47.4%. The abstinent patients had a significantly larger lesion volume than the relapsed ones, but a larger lesion volume also increased the risk of adverse events. 5 years after surgery, the abstinent patients showed significant decreases on the Psychoticism (EPQ-P) and Neuroticism (EPQ-N) scores by EPQ-RSC, a significant decline on the Global Severity Index and the subscores in all 10 dimensions by SCL-90-R, significant decreases on the BDI and Y-BOCS scores, and significant improvements on the scores of all domains by WHOQOL-BREF, while for the relapsed patients, only the subscores of obsessive-compulsive by SCL-90-R and the Y-BOCS scores significantly decreased. Postoperative analysis revealed that the abstinent patients had a significantly better score than the relapsed ones by various instruments, and NAc lesion volumes and locations did not correlate with the outcome of any of these instruments. The bilateral ablation of NAc by stereotactic neurosurgery was a feasible method for alleviating psychological dependence on opiate drugs and preventing a relapse. Long-term follow-up suggested that surgery can improve the personality and psychopathological profile of opiate addicts with a trend towards normal levels, provided persistent abstinence can be maintained; relapse, on the other hand, may ruin this effect. Copyright © 2012 S. Karger AG, Basel.
Long, David E; Tann, Mark; Huang, Ke Colin; Bartlett, Gregory; Galle, James O; Furukawa, Yukie; Maluccio, Mary; Cox, John A; Kong, Feng-Ming Spring; Ellsworth, Susannah G
2018-05-01
Hepatobiliary iminodiacetic acid (HIDA) scans provide global and regional assessments of liver function that can serve as a road map for functional avoidance in stereotactic body radiation therapy (SBRT) planning. Functional liver image guided hepatic therapy (FLIGHT), an innovative planning technique, is described and compared with standard planning using functional dose-volume histograms. Thresholds predicting for decompensation during follow up are evaluated. We studied 17 patients who underwent HIDA scans before SBRT. All SBRT cases were replanned using FLIGHT. The following dosimetric endpoints were compared for FLIGHT versus standard SBRT planning: functional residual capacity <15 Gy (FRC 15 HIDA), mean liver dose (MLD), equivalent uniform dose (EUD), and functional EUD (FEUD). Receiver operating characteristics curves were used to evaluate whether baseline HIDA values, standard cirrhosis scoring, and/or dosimetric data predicted clinical decompensation. Compared with standard planning, FLIGHT significantly improved FRC 15 HIDA (mean improvement: 5.3%) as well as MLD, EUD, and FEUD (P < .05). Considerable interindividual variations in the extent of benefit were noted. Decompensation during follow-up was associated with baseline global HIDA <2.915%/min/m 2 , FRC 15 HIDA <2.11%/min/m 2 , and MELD ≥11 (P < .05). FLIGHT with HIDA-based parameters may complement blood chemistry-based assessments of liver function and facilitate individualized, adaptive liver SBRT planning. Copyright © 2018. Published by Elsevier Inc.
Quantification of intraventricular blood clot in MR-guided focused ultrasound surgery
NASA Astrophysics Data System (ADS)
Hess, Maggie; Looi, Thomas; Lasso, Andras; Fichtinger, Gabor; Drake, James
2015-03-01
Intraventricular hemorrhage (IVH) affects nearly 15% of preterm infants. It can lead to ventricular dilation and cognitive impairment. To ablate IVH clots, MR-guided focused ultrasound surgery (MRgFUS) is investigated. This procedure requires accurate, fast and consistent quantification of ventricle and clot volumes. We developed a semi-autonomous segmentation (SAS) algorithm for measuring changes in the ventricle and clot volumes. Images are normalized, and then ventricle and clot masks are registered to the images. Voxels of the registered masks and voxels obtained by thresholding the normalized images are used as seed points for competitive region growing, which provides the final segmentation. The user selects the areas of interest for correspondence after thresholding and these selections are the final seeds for region growing. SAS was evaluated on an IVH porcine model. SAS was compared to ground truth manual segmentation (MS) for accuracy, efficiency, and consistency. Accuracy was determined by comparing clot and ventricle volumes produced by SAS and MS, and comparing contours by calculating 95% Hausdorff distances between the two labels. In Two-One-Sided Test, SAS and MS were found to be significantly equivalent (p < 0.01). SAS on average was found to be 15 times faster than MS (p < 0.01). Consistency was determined by repeated segmentation of the same image by both SAS and manual methods, SAS being significantly more consistent than MS (p < 0.05). SAS is a viable method to quantify the IVH clot and the lateral brain ventricles and it is serving in a large-scale porcine study of MRgFUS treatment of IVH clot lysis.
Aksoy, Didem; Bammer, Roland; Mlynash, Michael; Venkatasubramanian, Chitra; Eyngorn, Irina; Snider, Ryan W.; Gupta, Sandeep N.; Narayana, Rashmi; Fischbein, Nancy; Wijman, Christine A. C.
2013-01-01
Background Spontaneous intracerebral hemorrhage (ICH) is associated with blood–brain barrier (BBB) injury, which is a poorly understood factor in ICH pathogenesis, potentially contributing to edema formation and perihematomal tissue injury. We aimed to assess and quantify BBB permeability following human spontaneous ICH using dynamic contrast‐enhanced magnetic resonance imaging (DCE MRI). We also investigated whether hematoma size or location affected the amount of BBB leakage. Methods and Results Twenty‐five prospectively enrolled patients from the Diagnostic Accuracy of MRI in Spontaneous intracerebral Hemorrhage (DASH) study were examined using DCE MRI at 1 week after symptom onset. Contrast agent dynamics in the brain tissue and general tracer kinetic modeling were used to estimate the forward leakage rate (Ktrans) in regions of interest (ROI) in and surrounding the hematoma and in contralateral mirror–image locations (control ROI). In all patients BBB permeability was significantly increased in the brain tissue immediately adjacent to the hematoma, that is, the hematoma rim, compared to the contralateral mirror ROI (P<0.0001). Large hematomas (>30 mL) had higher Ktrans values than small hematomas (P<0.005). Ktrans values of lobar hemorrhages were significantly higher than the Ktrans values of deep hemorrhages (P<0.005), independent of hematoma volume. Higher Ktrans values were associated with larger edema volumes. Conclusions BBB leakage in the brain tissue immediately bordering the hematoma can be measured and quantified by DCE MRI in human ICH. BBB leakage at 1 week is greater in larger hematomas as well as in hematomas in lobar locations and is associated with larger edema volumes. PMID:23709564
Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H
1997-12-01
Although studies have shown that testosterone receptor blockade with flutamide after hemorrhage restores the depressed immune function, it remains unknown whether administration of flutamide following trauma and hemorrhage and resuscitation has any salutary effects on the depressed cardiovascular and hepatocellular functions. To study this, male rats underwent a laparotomy (representing trauma) and were then bled and maintained at a mean arterial pressure (MAP) of 40 mmHg until the animals could not maintain this pressure. Ringer lactate was given to maintain a MAP of 40 mmHg until 40% of the maximal shed blood volume was returned in the form of Ringer lactate. The rats were then resuscitated with four times the shed blood volume in the form of Ringer lactate over 60 min. Flutamide (25 mg/kg) or an equal volume of the vehicle propanediol was injected subcutaneously 15 min before the end of resuscitation. Various in vivo heart performance parameters (e.g., maximal rate of the pressure increase or decrease), cardiac output, and hepatocellular function (i.e., the maximum velocity and the overall efficiency of indocyanine green clearance) were determined at 20 h after resuscitation. Additionally, hepatic microvascular blood flow (HMBF) was determined using a laser Doppler flowmeter. The results indicate that left ventricular performance, cardiac output, HMBF, and hepatocellular function decreased significantly at 20 h after the completion of trauma, hemorrhage, and resuscitation. Administration of the testosterone receptor blocker flutamide, however, significantly improved cardiac performance, HMBF, and hepatocellular function. Thus flutamide appears to be a novel and useful adjunct for improving cardiovascular and hepatocellular functions in males following trauma and hemorrhagic shock.
Recurrent hemorrhage in hemangioblastoma involving the posterior fossa: Case report
Marvin, Eric; Akhter, Asad S.; Coppens, Jeroen R.
2017-01-01
Background: Hemangioblastomas (HGBs) are the most common primary intra-axial posterior fossa tumor in adults. Although spontaneous hemorrhage of these tumors is exceedingly rare, despite their vascular nature, we describe a case of recurrent hemorrhage with associated tonsillar herniation, and demonstrate that a surgical approach can provide a suitable outcome. Case Description: A 54-year-old female with von Hippel-Lindau (VHL) syndrome presented with acute loss of consciousness and Glasgow Coma Scale (GCS) was 4. Computed tomographic (CT) images demonstrated large volume subarachnoid hemorrhage of the posterior fossa with intraventricular extension and intraparenchymal hemorrhage involving the right cerebellar tonsil. Magnetic resonance imaging (MRI) displayed three lesions in the posterior fossa, two near the hemorrhage site. Patient underwent suboccipital craniectomy with a decent recovery followed by radiosurgery as she refused resection. A second hemorrhage occurred ultimately prompting surgical resection of the three posterior fossa lesions, with a reasonable postoperative course. Conclusion: Hemorrhage of HGBs of the posterior fossa can present in conjunction of tonsillar herniation. Re-hemorrhage appears to be likely if prior acute hemorrhage has occurred. A stepwise approach of surgical decompression and resection may provide the best outcome. PMID:28713626
Kaidar-Person, Orit; Zagar, Timothy M; Deal, Allison; Moschos, Stergios J; Ewend, Matthew G; Sasaki-Adams, Deanna; Lee, Carrie B; Collichio, Frances A; Fried, David; Marks, Lawrence B; Chera, Bhishamjit S
2017-07-01
Stereotactic radiotherapy (SRT) is the standard treatment for patients with limited number of brain metastases. In the past few years, newer immunotherapies (immune checkpoint inhibitors) have been proven to prolong survival in patients with metastatic melanoma. The safety of the combination of SRT and immunotherapy for brain metastases is unknown. We retrospectively identified patients with melanoma brain metastases treated with SRT between 2007 and 2015. Patients who did not have at least 3 months of follow-up with imaging after SRT were excluded from the analysis. Outcomes were compared between patients who were treated with or without immunotherapy. A total of 58 patients were included; of these, 29 were treated with SRT and immunotherapy. MAPK inhibitors (BRAF, MEK inhibitors) were used more often in the immunotherapy group (nine vs. two patients). There was a higher incidence of intracranial complications in patients treated with immunotherapy and SRT. Eight patients had radiation necrosis; all occurred in patients who were treated with immunotherapy. Nine patients had hemorrhage, of which seven occurred in patients who were treated with immunotherapy (P=0.08). However, patients treated with immunotherapy and SRT had a significant overall survival advantage compared with SRT without immunotherapy (15 vs. 6 months, P=0.0013). Patients treated with SRT and immunotherapy have a higher incidence/risk of intracranial complications, but a longer overall survival.
MRI markers of small vessel disease in lobar and deep hemispheric intracerebral hemorrhage
Smith, Eric E.; Nandigam, Kaveer R.N.; Chen, Yu-Wei; Jeng, Jed; Salat, David; Halpin, Amy; Frosch, Matthew; Wendell, Lauren; Fazen, Louis; Rosand, Jonathan; Viswanathan, Anand; Greenberg, Steven M.
2014-01-01
Background MRI evidence of small vessel disease is common in intracerebral hemorrhage (ICH). We hypothesized that ICH caused by cerebral amyloid angiopathy (CAA) or hypertensive vasculopathy would have different distributions of MRI T2 white matter hyperintensity (WMH) and microbleeds (MB). Methods Data were analyzed from 133 consecutive patients with primary supratentorial ICH and adequate MRI sequences. CAA was diagnosed using the Boston criteria. WMH segmentation was performed using a validated semi-automated method. WMH and MB were compared according to site of symptomatic hematoma origin (lobar vs. deep) or by pattern of hemorrhages, including both hematomas and MB, on MRI GRE sequence (grouped as lobar only--probable CAA, lobar only--possible CAA, deep hemispheric only, or mixed lobar and deep hemorrhages). Results Lobar and deep hemispheric hematoma patients had similar median nWMH volumes (19.5 cm vs. 19.9 cm3, p=0.74) and prevalence of ≥1 MB (54% vs. 52%, p=0.99). The supratentorial WMH distribution was similar according to hemorrhage location category, however the prevalence of brainstem T2 hyperintensity was lower in lobar hematoma vs. deep hematoma (54% vs. 70%, p=0.004). Mixed ICH was common (23%). Mixed ICH patients had large nWMH volumes and a posterior distribution of cortical hemorrhages similar to that seen in CAA. Conclusions WMH distribution is largely similar between CAA-related and non-CAA-related ICH. Mixed lobar and deep hemorrhages are seen on MRI GRE in up to one quarter of patients; in these patients both hypertension and CAA may be contributing to the burden of WMH. PMID:20689084
MRI markers of small vessel disease in lobar and deep hemispheric intracerebral hemorrhage.
Smith, Eric E; Nandigam, Kaveer R N; Chen, Yu-Wei; Jeng, Jed; Salat, David; Halpin, Amy; Frosch, Matthew; Wendell, Lauren; Fazen, Louis; Rosand, Jonathan; Viswanathan, Anand; Greenberg, Steven M
2010-09-01
MRI evidence of small vessel disease is common in intracerebral hemorrhage (ICH). We hypothesized that ICH caused by cerebral amyloid angiopathy (CAA) or hypertensive vasculopathy would have different distributions of MRI T2 white matter hyperintensity (WMH) and microbleeds. Data were analyzed from 133 consecutive patients with primary supratentorial ICH and adequate MRI sequences. CAA was diagnosed using the Boston criteria. WMH segmentation was performed using a validated semiautomated method. WMH and microbleeds were compared according to site of symptomatic hematoma origin (lobar versus deep) or by pattern of hemorrhages, including both hematomas and microbleeds, on MRI gradient recalled echo sequence (grouped as lobar only-probable CAA, lobar only-possible CAA, deep hemispheric only, or mixed lobar and deep hemorrhages). Patients with lobar and deep hemispheric hematoma had similar median normalized WMH volumes (19.5 cm versus 19.9 cm(3), P=0.74) and prevalence of >or=1 microbleed (54% versus 52%, P=0.99). The supratentorial WMH distribution was similar according to hemorrhage location category; however, the prevalence of brain stem T2 hyperintensity was lower in lobar hematoma versus deep hematoma (54% versus 70%, P=0.004). Mixed ICH was common (23%). Patients with mixed ICH had large normalized WMH volumes and a posterior distribution of cortical hemorrhages similar to that seen in CAA. WMH distribution is largely similar between CAA-related and non-CAA-related ICH. Mixed lobar and deep hemorrhages are seen on MRI gradient recalled echo sequence in up to one fourth of patients; in these patients, both hypertension and CAA may be contributing to the burden of WMH.
HSD is a better resuscitation fluid for hemorrhagic shock with pulmonary edema at high altitude.
Liu, Liang-Ming; Hu, De-Yao; Zhou, Xue-Wu; Liu, Jiang-Cang; Li, Ping
2008-12-01
To investigate the fluid tolerance of hemorrhagic shock with pulmonary edema (HSPE) at high altitude in unacclimated rats and the beneficial effect of 7.5% hypertonic saline/6% dextran (HSD). One hundred seventy-six Sprague-Dawley rats, transported to LaSa, Tibet, 3,760 m above the sea level, were anesthetized with sodium pentobarbital (30 mg/kg, i.p.) within 1 week. Hemorrhagic shock with pulmonary edema was induced by bloodletting (50 mmHg for 1 h) plus intravenous injection of oleic acid (50 microL/kg). Seventy-seven rats were equally divided into 11 groups (n = 7/group) including sham-operated control group; hemorrhagic shock control group; HSPE control group; HSPE plus 0.5-, 1.0-, 1.5-, 2.0-, or 3.0-fold volumes of lactated Ringer's solution (LR) groups; and HSPE plus 4, 6, and 8 mL/kg of HSD groups. Hemodynamic parameters including mean arterial blood pressure, left intraventricular systolic pressure, and the maximal change rate of intraventricular pressure rise or decline (+/-dp/dtmax) were observed at baseline and at 15, 30, 60, and 120 min after infusion; blood gases were measured at 30 and 120 min after infusion, and the water content of lung and brain was determined at 120 min after infusion. Additional 99 rats were used to observe the effect of these treatments on the survival time of HSPE rats; 0.5 volume of LR infusion slightly increased the mean arterial blood pressure, left intraventricular systolic pressure, and +/-dp/dtmax and prolonged the survival time of HSPE animals as compared with the HSPE group (P < 0.05 - 0.01); it did not increase the water content of lung and brain and had no marked influences on blood gases. One volume of LR infusion had somewhat improved the hemodynamic parameters for HSPE animals, but had no apparent effect on the survival time and the water content of lung and brain. Lactate Ringer's solution infusion, 1.5, 2, and 3 volumes, significantly deteriorated the hemodynamic parameters, increased the water content of lung, and decreased the survival time of HSPE animals. Hypertonic saline/6% dextran (4 - 8 mL/kg) significantly increased the hemodynamic parameters, improved the blood gases, decreased the water content of lung and brain, and prolonged the survival time of HSPE rats. Among the three dosages of HSD, 6 mL/kg of HSD had the best effect. The tolerance of fluid infusion for hemorrhagic shock with pulmonary edema at high altitude is significantly decreased. More than one volume of LR infusion would aggravate the pulmonary edema and exacerbate the resuscitation effect, but only one volume of LR cannot reach the effective volume resuscitation. Small volume of HSD could better resuscitate hemorrhagic shock with pulmonary edema at high altitude.
Hoe, Yeon; Choi, Young Jae; Kim, Jeong Hoon; Kwon, Do Hoon; Kim, Chang Jin; Cho, Young Hyun
2015-10-01
To investigate the risks and pattern of evolution of peritumoral brain edema (PTE) after stereotactic radiosurgery (SRS) for asymptomatic intracranial meningiomas. A retrospective study was conducted on 320 patients (median age 56 years, range 24-87 years) who underwent primary Gamma Knife radiosurgery for asymptomatic meningiomas between 1998 and 2012. The median tumor volume was 2.7 cc (range 0.2-10.5 cc) and the median follow-up was 48 months (range 24-168 months). Volumetric data sets for tumors and PTE on serial MRIs were analyzed. The edema index (EI) was defined as the ratio of the volume of PTE including tumor to the tumor volume, and the relative edema indices (rEIs) were calculated from serial EIs normalized against the baseline EI. Risk factors for PTE were analyzed using logistic regression. Newly developed or increased PTE was noted in 49 patients (15.3%), among whom it was symptomatic in 28 patients (8.8%). Tumor volume larger than 4.2 cc (p<0.001), hemispheric tumor location (p=0.005), and pre-treatment PTE (p<0.001) were associated with an increased risk of PTE. rEI reached its maximum value at 11 months after SRS and decreased thereafter, and symptoms resolved within 24 months in most patients (85.7%). Caution should be exercised in decision-making on SRS for asymptomatic meningiomas of large volume (>4.2 cc), of hemispheric location, or with pre-treatment PTE. PTE usually develops within months, reaches its maximum degree until a year, and resolves within 2 years after SRS.
Dose gradient curve: A new tool for evaluating dose gradient.
Sung, KiHoon; Choi, Young Eun
2018-01-01
Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, Brett W., E-mail: coxb@mskcc.org; Spratt, Daniel E.; Lovelock, Michael
2012-08-01
Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE)more » with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic disease along the circumference of the epidural space. Conclusions: This report provides consensus guidelines for target volume definition for spinal metastases receiving upfront SRS in common clinical situations.« less
Electrical conductivity changes during irreversible electroporation treatment of brain cancer.
Garcia, Paulo A; Rossmeisl, John H; Davalos, Rafael V
2011-01-01
Irreversible electroporation (IRE) is a new minimally invasive technique to kill tumors and other undesirable tissue in a non-thermal manner. During an IRE treatment, a series of short and intense electric pulses are delivered to the region of interest to destabilize the cell membranes in the tissue and achieve spontaneous cell death. The alteration of the cellular membrane results in a dramatic increase in electrical conductivity during IRE as in other electroporation-based-therapies. In this study, we performed the planning and execution of an IRE brain cancer treatment using MRI reconstructions of the tumor and a multichannel array that served as a stereotactic fiducial and electrode guide. Using the tumor reconstructions within our numerical simulations, we developed equations relating the increase in tumor conductivity to calculated currents and volumes of tumor treated with IRE. We also correlated the experimental current measured during the procedure to an increase in tumor conductivity ranging between 3.42-3.67 times the baseline conductivity, confirming the physical phenomenon that has been detected in other tissues undergoing similar electroporation-based treatments.
Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, Justin, E-mail: justin.roper@emory.edu; Department of Biostatistics and Bioinformatics, Winship Cancer Institute of Emory University, Atlanta, Georgia; Chanyavanich, Vorakarn
2015-11-01
Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was relatedmore » to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunlap, Neal E.; Cai, Jing; Biedermann, Gregory B.
Purpose: To identify the dose-volume parameters that predict the risk of chest wall (CW) pain and/or rib fracture after lung stereotactic body radiotherapy. Methods and Materials: From a combined, larger multi-institution experience, 60 consecutive patients treated with three to five fractions of stereotactic body radiotherapy for primary or metastatic peripheral lung lesions were reviewed. CW pain was assessed using the Common Toxicity Criteria for pain. Peripheral lung lesions were defined as those located within 2.5 cm of the CW. A minimal point dose of 20 Gy to the CW was required. The CW volume receiving >=20, >=30, >=40, >=50, andmore » >=60 Gy was determined and related to the risk of CW toxicity. Results: Of the 60 patients, 17 experienced Grade 3 CW pain and five rib fractures. The median interval to the onset of severe pain and/or fracture was 7.1 months. The risk of CW toxicity was fitted to the median effective concentration dose-response model. The CW volume receiving 30 Gy best predicted the risk of severe CW pain and/or rib fracture (R{sup 2} = 0.9552). A volume threshold of 30 cm{sup 3} was observed before severe pain and/or rib fracture was reported. A 30% risk of developing severe CW toxicity correlated with a CW volume of 35 cm{sup 3} receiving 30 Gy. Conclusion: The development of CW toxicity is clinically relevant, and the CW should be considered an organ at risk in treatment planning. The CW volume receiving 30 Gy in three to five fractions should be limited to <30 cm{sup 3}, if possible, to reduce the risk of toxicity without compromising tumor coverage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopp, Christine, E-mail: Christine.Kopp@lrz.tu-muenchen.de; Theodorou, Marilena; Poullos, Nektarios
2012-03-01
Purpose: To evaluate tumor control and side effects associated with fractionated stereotactic radiotherapy (FSRT) in the management of residual or recurrent nonfunctioning pituitary adenomas (NFPAs). Methods and Materials: We assessed exact tumor volume shrinkage in 16 patients with NFPA after FSRT. All patients had previously undergone surgery. Gross tumor volume (GTV) was outlined on contrast-enhanced magnetic resonance imaging (MRI) before and median 63 months (range, 28-100 months) after FSRT. MRI was performed as an axial three-dimensional gradient echo T1-weighted sequence at 1.6-mm slice thickness without gap (3D MRI). Results: Mean tumor size of all 16 pituitary adenomas before treatment wasmore » 7.4 mL (3.3-18.9 mL). We found shrinkage of the treated pituitary adenoma in all patients. Within a median follow-up of 63 months (28-100 months) an absolute mean volume reduction of 3.8 mL (0.9-12.4 mL) was seen. The mean relative size reduction compared with the volume before radiotherapy was 51% (22%-95%). Shrinkage measured by 3D MRI was greater at longer time intervals after radiotherapy. A strong negative correlation between the initial tumor volume and the absolute volume reduction after FSRT was found. There was no correlation between tumor size reduction and patient age, sex, or number of previous surgeries. Conclusions: By using 3D MRI in all patients undergoing FSRT of an NFPA, tumor shrinkage is detected. Our data demonstrate that volumetric assessment based on 3D MRI adds additional information to routinely used radiological response measurements. After FSRT a mean relative size reduction of 51% can be expected within 5 years.« less
Brachytherapy of prostate cancer after colectomy for colorectal cancer: pilot experience.
Koutrouvelis, Panos G; Theodorescu, Dan; Katz, Stuart; Lailas, Niko; Hendricks, Fred
2005-01-01
We present a method of brachytherapy for prostate cancer using a 3-dimensional stereotactic system and computerized tomography guidance in patients without a rectum due to previous treatment for colorectal cancer. From June 1994 to November 2003 a cohort of 800 patients were treated with brachytherapy for prostate cancer. Four patients had previously been treated for colorectal cancer with 4,500 cGy external beam radiation therapy, abdominoperineal resection and chemotherapy, while 1 underwent abdominoperineal resection alone for ulcerative colitis. Because of previous radiation therapy, these patients were not candidates for salvage external beam radiation therapy or radical prostatectomy and they had no rectum for transrectal ultrasound guided transperineal brachytherapy or cryotherapy. A previously described, 3-dimensional stereotactic system was used for brachytherapy in these patients. The prescribed radiation dose was 120 to 144 Gy with iodine seeds in rapid strand format. Patient followup included clinical examination and serum prostate specific antigen measurement. Average followup was 18.6 months. Four patients had excellent biochemical control, while 1 had biochemical failure. Patients did not experience any gastrointestinal morbidity. One patient had a stricture of the distal ureter, requiring a stent. Three-dimensional computerized tomography guided brachytherapy for prostate cancer in patients with a history of colorectal cancer who have no rectum is a feasible method of treatment.
Memon, Muhammad Ali; Ahmed, Usman; Saleem, Muhammad Abid; Bhatti, Amer Iqtidar; Ahmed, Naveed; Hashim, Abdul Sattar M.
2012-01-01
Objective To evaluate the clinical outcome of linear accelerator based multisession stereotactic radiosurgery (SRS) for large benign brain tumors of >3cm. Methods Between June 2009 and May 2011, 35 patients having large benign brain tumors of >3cm (≥15 cm3) were treated by multisession stereotactic radiosurgery. This retrospective study was carried out at Neurospinal & Medical Institute Karachi. There were 17 (48.6 %) males and 18(51.4 %) females. Median age was 36 years (range: 13-65 years). Median target volume was 49.4 cm3 (range: 15-184 cm3). The median marginal dose was 25 Gy (range: 20–27.5Gy) prescribed to a median 75% isodose line (range: 65-100 %). Median number of 5 fractions were used ranging 3-5 fractions. Results All the patients tolerated treatment very well. 21 (58.3%) patients had remarkable clinical improvement of neurological symptoms, 14 (38.9%) patients had stable symptoms, and only one patient had transient worsening of symptoms. No permanent neurological damage or radiation injury was seen. Radiologically, 9 (25.7%) patients achieved reduction in size of the tumor, 26(74.3 %) patients were having stable disease, and overall control rate was found to be 100 %. Median follow-up time from the end of SRS was 6.4 months (range: 1-22.5months). Conclusion Linear accelerator based multisession stereotactic radiosurgery for large benign brain tumors of >3cm is effective and well tolerated. PMID:29296340
Lee, Cheng-Chia; Trifiletti, Daniel M; Sahgal, Arjun; DeSalles, Antonio; Fariselli, Laura; Hayashi, Motohiro; Levivier, Marc; Ma, Lijun; Álvarez, Roberto Martínez; Paddick, Ian; Regis, Jean; Ryu, Samuel; Slotman, Ben; Sheehan, Jason
2018-03-15
Stereotactic radiosurgery (SRS) has become popular as a standard treatment for cavernous sinus (CS) meningiomas. To summarize the published literature specific to the treatment of CS meningioma with SRS found through a systematic review, and to create recommendations on behalf of the International Stereotactic Radiosurgery Society. Articles published from January 1963 to December 2014 were systemically reviewed. Three electronic databases, PubMed, EMBASE, and The Cochrane Central Register of Controlled Trials, were searched. Publications in English with at least 10 patients (each arm) were included. Of 569 screened abstracts, a total of 49 full-text articles were included in the analysis. All studies were retrospective. Most of the reports had favorable outcomes with 5-yr progression-free survival (PFS) rates ranging from 86% to 99%, and 10-yr PFS rates ranging from 69% to 97%. The post-SRS neurological preservation rate ranged from 80% to 100%. Resection can be considered for the treatment of larger (>3 cm in diameter) and symptomatic CS meningioma in patients both receptive to and medically eligible for open surgery. Adjuvant or salvage SRS for residual or recurrent tumor can be utilized depending on factors such as tumor volume and proximity to adjacent critical organs at risk. The literature is limited to level III evidence with respect to outcomes of SRS in patients with CS meningioma. Based on the observed results, SRS offers a favorable benefit to risk profile for patients with CS meningioma.
Loeffler, J S; Rossitch, E; Siddon, R; Moore, M R; Rockoff, M A; Alexander, E
1990-05-01
Between 1986 and 1988, 16 children were treated for 10 arteriovenous malformations and 6 recurrent intracranial tumors with stereotactic radiation therapy using a modified Clinac 6/100 linear accelerator. The median age of our patients was 10.5 years. For the group with arteriovenous malformation, follow-up ranged from 6 months to 37 months (median was 20 months). No patient bled during the follow-up period. Five of eight patients with follow-up longer than 12 months have achieved complete obliteration of their arteriovenous malformation by angiogram. The four remaining patients who have not achieved a complete obliteration are awaiting their 2-year posttreatment angiogram. The other patient has been treated within the year and have not yet been studied. Five of the six recurrent tumor patients are alive with a median follow-up of 8 months. The remaining patient was controlled locally, but he died of recurrent disease outside the area treated with radiosurgery. The radiographic responses of these patients have included three complete responses, two substantial reductions in tumor volume (greater than 50%) and one stabilization. Despite previous radiotherapy, there have been no significant complications in these patients. We conclude that stereotactic radiation therapy using a standard linear accelerator is an effective and safe technique in the treatment of selected intracranial arteriovenous malformations and tumors in children. In addition, stereotactic radiosurgery may have unique applications in the treatment of localized primary and recurrent pediatric brain tumors.
Liu, Liping; Wang, Yilong; Meng, Xia; Li, Na; Tan, Ying; Nie, Ximing; Liu, Dacheng; Zhao, Xingquan
2017-04-01
Rationale Acute intracerebral hemorrhage inflicts a high-economic and -health burden. Computed tomography angiography spot sign is a predictor of hematoma expansion, is associated with poor clinical outcome and is an important stratifying variable for patients treated with haemostatic therapy. Aims We aim to compare the effect of treatment with tranexamic acid to placebo for the prevention of hemorrhage growth in patients with high-risk acute intracerebral hemorrhage with a positive spot sign. Design The tranexamic acid for acute intracerebral hemorrhage growth predicted by spot sign (TRAIGE) is a prospective, multicenter, placebo-controlled, double-blind, investigator-led, randomized clinical trial that will include an estimated 240 participants. Patients with intracerebral hemorrhage demonstrating symptom onset within 8 h and with the spot sign as a biomarker for ongoing hemorrhage, and no contraindications for antifibrinolytic therapy, will be enrolled to receive either tranexamic acid or placebo. The primary outcome measure is the presence of hemorrhage growth defined as an increase in intracerebral hemorrhage volume >33% or >6 ml from baseline to 24 ± 2 h. The secondary outcomes include safety and clinical outcomes. Conclusion The TRAIGE trial evaluates the efficacy of haemostatic therapy with tranexamic acid in the prevention of hemorrhage growth among high-risk patients with acute intracerebral hemorrhage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young-Hoon; Department of Neurosurgery, Seoul National University College of Medicine, Seoul; Kim, Dong Gyu, E-mail: gknife@plaza.snu.ac.kr
2013-01-01
Purpose: We evaluated the prognostic factors for hearing outcomes after stereotactic radiosurgery (SRS) for unilateral sporadic intracanalicular vestibular schwannomas (IC-VSs) as a clinical homogeneous group of VSs. Methods and Materials: Sixty consecutive patients with unilateral sporadic IC-VSs, defined as tumors in the internal acoustic canal, and serviceable hearing (Gardner-Roberson grade 1 or 2) were treated with SRS as an initial treatment. The mean tumor volume was 0.34 {+-} 0.03 cm{sup 3} (range, 0.03-1.00 cm{sup 3}), and the mean marginal dose was 12.2 {+-} 0.1 Gy (range, 11.5-13.0 Gy). The median follow-up duration was 62 months (range, 36-141 months). Results: Themore » actuarial rates of serviceable hearing preservation were 70%, 63%, and 55% at 1, 2, and 5 years after SRS, respectively. In multivariate analysis, transient volume expansion of {>=}20% from initial tumor size was a statistically significant risk factor for loss of serviceable hearing and hearing deterioration (increase of pure tone average {>=}20 dB) (odds ratio = 7.638; 95% confidence interval, 2.317-25.181; P=.001 and odds ratio = 3.507; 95% confidence interval, 1.228-10.018; P=.019, respectively). The cochlear radiation dose did not reach statistical significance. Conclusions: Transient volume expansion after SRS for VSs seems to be correlated with hearing deterioration when defined properly in a clinically homogeneous group of patients.« less
Effects of Bovine Polymerized Hemoglobin in Coagulation in Controlled Hemorrhagic Shock in Swine
2005-01-01
continuous blood pressure monitoring. A pulmonary artery catheter was also inserted. To mimic soft tissue injury, the rectus abdominus muscle was crushed in...volume by catheter withdrawal of blood over 15 min (;1.7 mL/kg/min). Time 0 designated initiation of the rectus abdominus crush and concomitant hemorrhage
Preliminary model of fluid and solute distribution and transport during hemorrhage.
Gyenge, C C; Bowen, B D; Reed, R K; Bert, J L
2003-01-01
The distribution and transport of fluid, ions, and other solutes (plasma proteins and glucose) are described in a mathematical model of unresuscitated hemorrhage. The model is based on balances of each material in both the circulation and its red blood cells, as well as in a whole-body tissue compartment along with its cells. Exchange between these four compartments occurs by a number of different mechanisms. The hemorrhage model has as its basis a validated model, due to Gyenge et al., of fluid and solute exchange in the whole body of a standard human. Hypothetical but physiologically based features such as glucose and small ion releases along with cell membrane changes are incorporated into the hemorrhage model to describe the system behavior, particularly during larger hemorrhages. Moderate (10%-30% blood volume loss) and large (> 30% blood loss) hemorrhage dynamics are simulated and compared with available data. The model predictions compare well with the available information for both types of hemorrhages and provide a reasonable description of the progression of a large hemorrhage from the compensatory phase through vascular collapse.
Efficacy and safety of recombinant activated factor VII for acute intracerebral hemorrhage.
Mayer, Stephan A; Brun, Nikolai C; Begtrup, Kamilla; Broderick, Joseph; Davis, Stephen; Diringer, Michael N; Skolnick, Brett E; Steiner, Thorsten
2008-05-15
Intracerebral hemorrhage is the least treatable form of stroke. We performed this phase 3 trial to confirm a previous study in which recombinant activated factor VII (rFVIIa) reduced growth of the hematoma and improved survival and functional outcomes. We randomly assigned 841 patients with intracerebral hemorrhage to receive placebo (268 patients), 20 microg of rFVIIa per kilogram of body weight (276 patients), or 80 microg of rFVIIa per kilogram (297 patients) within 4 hours after the onset of stroke. The primary end point was poor outcome, defined as severe disability or death according to the modified Rankin scale 90 days after the stroke. Treatment with 80 microg of rFVIIa per kilogram resulted in a significant reduction in growth in volume of the hemorrhage. The mean estimated increase in volume of the intracerebral hemorrhage at 24 hours was 26% in the placebo group, as compared with 18% in the group receiving 20 microg of rFVIIa per kilogram (P=0.09) and 11% in the group receiving 80 microg (P<0.001). The growth in volume of intracerebral hemorrhage was reduced by 2.6 ml (95% confidence interval [CI], -0.3 to 5.5; P=0.08) in the group receiving 20 microg of rFVIIa per kilogram and by 3.8 ml (95% CI, 0.9 to 6.7; P=0.009) in the group receiving 80 microg, as compared with the placebo group. Despite this reduction in bleeding, there was no significant difference among the three groups in the proportion of patients with poor clinical outcome (24% in the placebo group, 26% in the group receiving 20 microg of rFVIIa per kilogram, and 29% in the group receiving 80 microg). The overall frequency of thromboembolic serious adverse events was similar in the three groups; however, arterial events were more frequent in the group receiving 80 microg of rFVIIa than in the placebo group (9% vs. 4%, P=0.04). Hemostatic therapy with rFVIIa reduced growth of the hematoma but did not improve survival or functional outcome after intracerebral hemorrhage. (ClinicalTrials.gov number, NCT00127283 [ClinicalTrials.gov].). Copyright 2008 Massachusetts Medical Society.
A CAD System for Hemorrhagic Stroke.
Nowinski, Wieslaw L; Qian, Guoyu; Hanley, Daniel F
2014-09-01
Computer-aided detection/diagnosis (CAD) is a key component of routine clinical practice, increasingly used for detection, interpretation, quantification and decision support. Despite a critical need, there is no clinically accepted CAD system for stroke yet. Here we introduce a CAD system for hemorrhagic stroke. This CAD system segments, quantifies, and displays hematoma in 2D/3D, and supports evacuation of hemorrhage by thrombolytic treatment monitoring progression and quantifying clot removal. It supports seven-step workflow: select patient, add a new study, process patient's scans, show segmentation results, plot hematoma volumes, show 3D synchronized time series hematomas, and generate report. The system architecture contains four components: library, tools, application with user interface, and hematoma segmentation algorithm. The tools include a contour editor, 3D surface modeler, 3D volume measure, histogramming, hematoma volume plot, and 3D synchronized time-series hematoma display. The CAD system has been designed and implemented in C++. It has also been employed in the CLEAR and MISTIE phase-III, multicenter clinical trials. This stroke CAD system is potentially useful in research and clinical applications, particularly for clinical trials.
Yock, Adam D; Pawlicki, Todd; Kim, Gwe-Ya
2016-07-01
In surface image guided radiosurgery, action limits are created to determine at what point intrafractional motion exhibited by the patient is large enough to warrant intervention. Action limit values remain constant across patients despite the fact that patient motion affects the target coverage of brain metastases differently depending on the planning technique and other treatment plan-specific factors. The purpose of this work was twofold. The first purpose was to characterize the sensitivity of single-met per iso and multimet per iso treatment plans to uncorrected patient motion. The second purpose was to describe a method to prospectively determine treatment plan-specific action limits considering this sensitivity. In their surface image guided radiosurgery technique, patient positioning is achieved with a thermoplastic mask that does not cover the patient's face. The patient's exposed face is imaged by a stereoscopic photogrammetry system. It is then compared to a reference surface and monitored throughout treatment. Seventy-two brain metastases (representing 29 patients) were used for this study. Twenty-five mets were treated individually ("single-met per iso plans"), and 47 were treated in a plan simultaneously with at least one other met ("multimet per iso plans"). For each met, the proportion of the gross tumor volume that remained within the 100% prescription isodose line was estimated under the influence of combinations of translations and rotations (0.0-3.0 mm and 0.0°-3.0°, respectively). The target volume and the prescription dose-volume were considered concentric spheres that each encompassed a volume determined from the treatment plan. Plan-specific contour plots and DVHs were created to illustrate the sensitivity of a specific lesion to uncorrected patient motion. Both single-met per iso and multimet per iso plans exhibited compromised target coverage under translations and rotations, though multimet per iso plans were considerably more sensitive to these transformations (2.3% and 39.8%, respectively). Plan-specific contour plots and DVHs were used to illustrate how size, distance from isocenter, and planning technique affect a particular met's sensitivity to motion. Stereotactic radiosurgery treatment plans that treat multiple brain metastases using a common isocenter are particularly susceptible to compromised target coverage as a result of uncorrected patient motion. The use of such a planning technique along with other treatment plan-specific factors should influence patient motion management. A graphical representation of the effect of translations and rotations on any particular plan can be generated to inform clinicians of the appropriate action limit when monitoring intrafractional motion.
Jensen, Dennis M; Kovacs, Thomas O G; Ohning, Gordon V; Ghassemi, Kevin; Machicado, Gustavo A; Dulai, Gareth S; Sedarat, Alireza; Jutabha, Rome; Gornbein, Jeffrey
2017-05-01
For 4 decades, stigmata of recent hemorrhage in patients with nonvariceal lesions have been used for risk stratification and endoscopic hemostasis. The arterial blood flow that underlies the stigmata rarely is monitored, but can be used to determine risk for rebleeding. We performed a randomized controlled trial to determine whether Doppler endoscopic probe monitoring of blood flow improves risk stratification and outcomes in patients with severe nonvariceal upper gastrointestinal hemorrhage. In a single-blind study performed at 2 referral centers we assigned 148 patients with severe nonvariceal upper gastrointestinal bleeding (125 with ulcers, 19 with Dieulafoy's lesions, and 4 with Mallory Weiss tears) to groups that underwent standard, visually guided endoscopic hemostasis (control, n = 76), or endoscopic hemostasis assisted by Doppler monitoring of blood flow under the stigmata (n = 72). The primary outcome was the rate of rebleeding after 30 days; secondary outcomes were complications, death, and need for transfusions, surgery, or angiography. There was a significant difference in the rates of lesion rebleeding within 30 days of endoscopic hemostasis in the control group (26.3%) vs the Doppler group (11.1%) (P = .0214). The odds ratio for rebleeding with Doppler monitoring was 0.35 (95% confidence interval, 0.143-0.8565) and the number needed to treat was 7. In a randomized controlled trial of patients with severe upper gastrointestinal hemorrhage from ulcers or other lesions, Doppler probe guided endoscopic hemostasis significantly reduced 30-day rates of rebleeding compared with standard, visually guided hemostasis. Guidelines for nonvariceal gastrointestinal bleeding should incorporate these results. ClinicalTrials.gov no: NCT00732212 (CLIN-013-07F). Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Murai, Taro; Sato, Kengo; Iwabuchi, Michio; Manabe, Yoshihiko; Ogino, Hiroyuki; Iwata, Hiromitsu; Tatewaki, Koshi; Yokota, Naoki; Ohta, Seiji; Shibamoto, Yuta
2016-03-01
Recurrent ependymomas were retreated with stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT). The efficacy, toxicities, and differences between SRS and FSRT were analyzed. Eight patients with recurrent ependymomas fulfilling the criteria described below were evaluated. Inclusion criteria were: (1) the patient had previously undergone surgery and conventional radiotherapy as first-line treatment; (2) targets were located in or adjacent to the eloquent area or were deep-seated; and (3) the previously irradiated volume overlapped the target lesion. FSRT was delivered to 18 lesions, SRS to 20 lesions. A median follow-up period was 23 months. The local control rate was 76 % at 3 years. No significant differences in local control were observed due to tumor size or fractionation schedule. Lesions receiving >25 Gy/5 fr or 21 Gy/3 fr did not recur within 1 year, whereas no dose-response relationship was observed in those treated with SRS. No grade ≥2 toxicity was observed. Our treatment protocol provided an acceptable LC rate and minimal toxicities. Because local recurrence of tumors may result in patient death, a minimum dose of 21 Gy/3 fr or 25 Gy/5 fr or higher may be most suitable for treatment of these cases.
Hetzel, Juergen; Spengler, Werner; Horger, Marius; Boeckeler, Michael
2015-06-01
Endoscopic lung volume reduction is an emerging technique meant to improve lung function parameters, quality of life, and exercise tolerance in patients with severe lung emphysema. This is the first report of lung volume reduction by autologous blood in a patient with non-bullous lung emphysema. A 74-year-old woman with heterogeneous lung emphysema developed accidentally diffuse lobar bleeding immediately after valve placement. Due to persistent hemorrhage, the valves had to be removed shortly thereafter. Despite extraction of the valves, respiratory function of the patient improved rapidly indicated also by a drop in the COPD assessment test questionnaire, 3 months later. This was consistent with both improvement of lung function tests and six-minute walking test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Algan, O; Giem, J; Young, J
Purpose: To investigate the doses received by the hippocampus and normal brain tissue during a course of stereotactic radiotherapy utilizing a single isocenter (SI) versus multiple isocenter (MI) in patients with multiple intracranial metastases. Methods: Seven patients imaged with MRI including SPGR sequence and diagnosed with 2–3 brain metastases were included in this retrospective study. Two sets of stereotactic IMRT treatment plans, (MI vs SI), were generated. The hippocampus was contoured on SPGR sequences and doses received by the hippocampus and whole brain were calculated. The prescribed dose was 25Gy in 5 fractions. The two groups were compared using t-testmore » analysis. Results: There were 17 lesions in 7 patients. The median tumor, right hippocampus, left hippocampus and brain volumes were: 3.37cc, 2.56cc, 3.28cc, and 1417cc respectively. In comparing the two treatment plans, there was no difference in the PTV coverage except in the tail of the DVH curve. All tumors had V95 > 99.5%. The only statistically significant parameter was the V100 (72% vs 45%, p=0.002, favoring MI). All other evaluated parameters including the V95 and V98 did not reveal any statistically significant differences. None of the evaluated dosimetric parameters for the hippocampus (V100, V80, V60, V40, V20, V10, D100, D90, D70, D50, D30, D10) revealed any statistically significant differences (all p-values > 0.31) between MI and SI plans. The total brain dose was slightly higher in the SI plans, especially in the lower dose regions, although this difference was not statistically significant. Utilizing brain-sub-PTV volumes did not change these results. Conclusion: The use of SI treatment planning for patients with up to 3 brain metastases produces similar PTV coverage and similar normal tissue doses to the hippocampus and the brain compared to MI plans. SI treatment planning should be considered in patients with multiple brain metastases undergoing stereotactic treatment.« less
Morihara, Ryuta; Yamashita, Toru; Kono, Syoichiro; Shang, Jingwei; Nakano, Yumiko; Sato, Kota; Hishikawa, Nozomi; Ohta, Yasuyuki; Heitmeier, Stefan; Perzborn, Elisabeth; Abe, Koji
2017-09-01
This study aimed to assess the risk of intracerebral hemorrhage (ICH) after tissue-type plasminogen activator (tPA) treatment in rivaroxaban compared with warfarin-pretreated male Wistar rat brain after ischemia in relation to activation profiles of protease-activated receptor-1, -2, -3, and -4 (PAR-1, -2, -3, and -4). After pretreatment with warfarin (0.2 mg/kg/day), low-dose rivaroxaban (60 mg/kg/day), high-dose rivaroxaban (120 mg/kg/day), or vehicle for 14 days, transient middle cerebral artery occlusion was induced for 90 min, followed by reperfusion with tPA (10 mg/kg/10 ml). Infarct volume, hemorrhagic volume, immunoglobulin G leakage, and blood parameters were examined. Twenty-four hours after reperfusion, immunohistochemistry for PARs was performed in brain sections. ICH volume was increased in the warfarin-pretreated group compared with the rivaroxaban-treated group. PAR-1, -2, -3, and -4 were widely expressed in the normal brain, and their levels were increased in the ischemic brain, especially in the peri-ischemic lesion. Warfarin pretreatment enhanced the expression of PAR-1 and PAR-2 in the peri-ischemic lesion, whereas rivaroxaban pretreatment did not. The present study shows a lower risk of brain hemorrhage in rivaroxaban-pretreated compared with warfarin-pretreated rats following tPA administration to the ischemic brain. It is suggested that the relative downregulation of PAR-1 and PAR-2 by rivaroxaban compared with warfarin pretreatment might be partly involved in the mechanism of reduced hemorrhagic complications in patients receiving rivaroxaban in clinical trials. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Intramuscular Tranexamic Acid in Tactical and Combat Settings.
Vu, Erik N; Wan, Wilson C Y; Yeung, Titus C; Callaway, David W
Uncontrolled hemorrhage remains a leading cause of preventable death in tactical and combat settings. Alternate routes of delivery of tranexamic acid (TXA), an adjunct in the management of hemorrhagic shock, are being studied. A working group for the Committee for Tactical Emergency Casualty Care reviewed the available evidence on the potential role for intramuscular (IM) administration of TXA in nonhospital settings as soon as possible from the point of injury. EMBASE and MEDLINE/PubMed databases were sequentially searched by medical librarians for evidence of TXA use in the following contexts and/or using the following keywords: prehospital, trauma, hemorrhagic shock, optimal timing, optimal dose, safe volume, incidence of venous thromboembolism (VTE), IM bioavailability. A total of 183 studies were reviewed. The strength of the available data was variable, generally weak in quality, and included laboratory research, case reports, retrospective observational reviews, and few prospective studies. Current volume and concentrations of available formulations of TXA make it, in theory, amenable to IM injection. Current bestpractice guidelines for large-volume injection (i.e., 5mL) support IM administration in four locations in the adult human body. One case series suggests complete bioavailability of IM TXA in healthy patients. Data are lacking on the efficacy and safety of IM TXA in hemorrhagic shock. There is currently insufficient evidence to support a strong recommendation for or against IM administration of TXA in the combat setting; however, there is an abundance of literature demonstrating efficacy and safety of TXA use in a broad range of patient populations. Balancing the available data and risk- benefit ratio, IM TXA should be considered a viable treatment option for tactical and combat applications. Additional studies should focus on the optimal dose and bioavailability of IM dosing of patients in hemorrhagic shock, with assessment of potential downstream sequelae. 2018.
Is gut the "motor" for producing hepatocellular dysfunction after trauma and hemorrhagic shock?
Wang, P; Ba, Z F; Cioffi, W G; Bland, K I; Chaudry, I H
1998-02-01
Although studies suggest that the gut may be the "motor" responsible for producing sepsis and multiple organ failure after injury, it is not known whether enterectomy prior to the onset of hemorrhage alters proinflammatory cytokines TNF and IL-6 and, if so, whether hepatocellular dysfunction and damage are prevented or attenuated under such conditions. Under methoxyflurane anesthesia, an enterectomy in the rat was performed by excision of the duodenum, jejunum, and ileum. The rats were then bled to and maintained at a mean arterial pressure of 40 mm Hg until 40% of the maximal shed volume was returned in the form of Ringer's lactate. The animals were then resuscitated with four times the volume of shed blood with Ringer's lactate over 1 h. At 1.5 h after the completion of resuscitation, hepatocellular function [i.e., the maximal velocity (Vmax) and transport efficiency (Km) of indocyanine green (ICG) clearance] was assessed by an in vivo ICG clearance technique. Blood samples were taken for the measurement of TNF, IL-6, and liver enzymes (i.e., SGPT and SGOT). Cardiac output and microvascular blood flow were determined by ICG dilution and laser Doppler flowmetry, respectively. The increase in circulating levels of TNF but not IL-6 was prevented by enterectomy prior to hemorrhage. The reduced Vmax and K(m) and elevated SGPT and SGOT following hemorrhage and resuscitation, however, were not significantly affected by prior enterectomy. Moreover, enterectomy before hemorrhage further reduced hepatic perfusion. Since enterectomy prior to the onset of hemorrhage does not prevent or attenuate the reduced ICG clearance and elevated liver enzymes despite downregulation of TNF production, it appears that the small intestine does not play a significant role in producing hepatocellular dysfunction and injury following trauma and hemorrhagic shock.
Tsao, May N; Sahgal, Arjun; Xu, Wei; De Salles, Antonio; Hayashi, Motohiro; Levivier, Marc; Ma, Lijun; Martinez, Roberto; Régis, Jean; Ryu, Sam; Slotman, Ben J; Paddick, Ian
2017-01-01
The aim of this systematic review was to develop International Stereotactic Radiosurgery Society (ISRS) consensus guideline statements for vestibular schwannoma. A systematic review of the literature was performed up to April 2015. A total of 55 full-text articles were included in the analysis. All studies were retrospective, except for 2 prospective quality of life studies. Five-year tumour control rates with Gamma Knife radiosurgery (RS), single fraction linac RS, or fractionated (either hypofractionated or conventional fractionation) stereotactic radiation therapy (FSRT) were similar at 81-100%. The single fraction RS series (linac or Gamma Knife) with tumour marginal doses between 12 and 14 Gy revealed 5-year tumour control rates of 90-99%, hearing preservation rates of 41-79%, facial nerve preservation rates of 95-100% and trigeminal preservation rates of 79-99%.There were 6 non-randomized studies comparing single fraction RS versus FSRT. There was no statistically significant difference in tumour control; HR=1.66 (95% CI 0.81, 3.42), p =0.17, facial nerve function; HR = 0.67 (95% CI 0.30, 1.49), p =0.33, trigeminal nerve function; HR = 0.80 (95% CI 0.41, 1.56), p =0.51, and hearing preservation; HR = 1.10 (95% CI 0.72, 1.68), p =0.65 comparing single fraction RS with FSRT.Nine quality of life reports yielded conflicting results as to which modality (surgery, observation, or radiation) was associated with better quality of life outcomes. There are no randomized trials to help guide management of patients with vestibular schwannoma. Within the limitations of the retrospective series, a number of consensus statements were made.
Sahgal, Arjun; Xu, Wei; De Salles, Antonio; Hayashi, Motohiro; Levivier, Marc; Ma, Lijun; Martinez, Roberto; Régis, Jean; Ryu, Sam; Slotman, Ben J.; Paddick, Ian
2017-01-01
Objectives The aim of this systematic review was to develop International Stereotactic Radiosurgery Society (ISRS) consensus guideline statements for vestibular schwannoma. Methods A systematic review of the literature was performed up to April 2015. Results A total of 55 full-text articles were included in the analysis. All studies were retrospective, except for 2 prospective quality of life studies. Five-year tumour control rates with Gamma Knife radiosurgery (RS), single fraction linac RS, or fractionated (either hypofractionated or conventional fractionation) stereotactic radiation therapy (FSRT) were similar at 81-100%. The single fraction RS series (linac or Gamma Knife) with tumour marginal doses between 12 and 14 Gy revealed 5-year tumour control rates of 90-99%, hearing preservation rates of 41-79%, facial nerve preservation rates of 95-100% and trigeminal preservation rates of 79-99%. There were 6 non-randomized studies comparing single fraction RS versus FSRT. There was no statistically significant difference in tumour control; HR=1.66 (95% CI 0.81, 3.42), p =0.17, facial nerve function; HR = 0.67 (95% CI 0.30, 1.49), p =0.33, trigeminal nerve function; HR = 0.80 (95% CI 0.41, 1.56), p =0.51, and hearing preservation; HR = 1.10 (95% CI 0.72, 1.68), p =0.65 comparing single fraction RS with FSRT. Nine quality of life reports yielded conflicting results as to which modality (surgery, observation, or radiation) was associated with better quality of life outcomes. Conclusions There are no randomized trials to help guide management of patients with vestibular schwannoma. Within the limitations of the retrospective series, a number of consensus statements were made. PMID:29296459
Honma, Kaneatsu; Koles, Nancy L; Alam, Hasan B; Rhee, Peter; Rollwagen, Florence M; Olsen, Cara; Keith, James C; Pollack, Matthew
2005-06-01
We have previously demonstrated that the administration of recombinant human interleukin-11 (rhIL-11) during resuscitation improves the blood pressure in a rodent model of hemorrhagic shock. The purpose of this study was to determine whether the effects of rhIL-11 could be reproduced in a large animal model and to elucidate the impact of rhIL-11 administration on the intravascular volume status and the degree of third space fluid loss after resuscitation. A 40% blood volume hemorrhage was induced in swine (n = 45, weight of 25-35 kg) followed by a 1-h shock period and resuscitation with 0.9% sodium chloride (three times the shed blood volume). The animals were randomized to receive sham hemorrhage (group I, sham); sham hemorrhage and 50 microg/kg rhIL-11 (group II, sham + IL-11); no drug (group III, saline); or 50 microg/kg rhIL-11 (group IV, IL-11). Blood and urine samples were obtained and analyzed at baseline, at the end of hemorrhaging, and thereafter once every hour. The pleural and peritoneal effusions were precisely quantified by using clinically accepted criteria. The mean arterial pressure (MAP) was higher postresuscitation (PR) in groups I, II, and IV (71.4 +/- 7.5 mmHg, 71.0 +/- 8.9 mmHg, and 72.9 +/- 12.3 mmHg, respectively) than in group III (59.9 +/- 10.9 mmHg), and the cardiac output of PR was higher in group IV (3.46 +/- 0.56 L/min) than in group III (2.99 +/- 0.62 L/min; P < 0.01). The difference in MAP between groups I and II became statistically significant at 40 min after rhIL-11 injection and such a difference persisted for 90 min. After resuscitation, the urine output was higher, and the urine specific gravity and third space fluid loss were lower in group IV (1434 +/- 325 mL and 1.0035, 82 +/- 21 mL) than in group III (958 +/- 390 mL and 1.0053, 125 +/- 32 mL; P < 0.05). In a porcine model of hemorrhagic shock, the administration of rhIL-11 at the start of resuscitation significantly improved the cardiac output and blood pressure. This strategy also significantly reduced the extent of third space fluid losses while also having a favorable impact on the intravascular volume status as evidenced by the improved urine output.
Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage
ERIC Educational Resources Information Center
Shen, Tao; Baker, Keith
2015-01-01
Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…
Is Survival Time After Hemorrhage a Heritable, Quantitative Trait?: An Initial Assessment
2008-06-01
The epidemiology of traumatic death. A population-based analysis. Arch Surg 128:571Y575, 1993. 5. Sauaia A, Moore FA, Moore EE, Moser KS, Brennan R...therapeutic goals and early warning of death. Arch Surg 106:630Y636, 1973. 752 SHOCK VOL. 29, NO. 6 KLEMCKE ET AL. Copyright @ 200 by the Shock...Hemorrhagic shock in rats. Measured blood volumes as the basis for the extent of hemorrhage. Arch Surg 99:484Y488, 1969. 19. Nose H, Morita M, Yawata T
2017-06-12
Adenocarcinoma of the Lung; Adenosquamous Cell Lung Cancer; Large Cell Lung Cancer; Recurrent Non-small Cell Lung Cancer; Squamous Cell Lung Cancer; Stage IIA Non-small Cell Lung Cancer; Stage IIB Non-small Cell Lung Cancer; Stage IIIA Non-small Cell Lung Cancer; Stage IIIB Non-small Cell Lung Cancer
Wagner, A; Ploder, O; Enislidis, G; Truppe, M; Ewers, R
1996-04-01
Interventional video tomography (IVT), a new imaging modality, achieves virtual visualization of anatomic structures in three dimensions for intraoperative stereotactic navigation. Partial immersion into a virtual data space, which is orthotopically coregistered to the surgical field, enhances, by means of a see-through head-mounted display (HMD), the surgeon's visual perception and technique by providing visual access to nonvisual data of anatomy, physiology, and function. The presented cases document the potential of augmented reality environments in maxillofacial surgery.
Yu, Yi-Lin; Yang, Yun-Ju; Lin, Chin; Hsieh, Chih-Chuan; Li, Chiao-Zhu; Feng, Shao-Wei; Tang, Chi-Tun; Chung, Tzu-Tsao; Ma, Hsin-I; Chen, Yuan-Hao; Ju, Da-Tong; Hueng, Dueng-Yuan
2017-01-01
Tumor control rates of pituitary adenomas (PAs) receiving adjuvant CyberKnife stereotactic radiosurgery (CK SRS) are high. However, there is currently no uniform way to estimate the time course of the disease. The aim of this study was to analyze the volumetric responses of PAs after CK SRS and investigate the application of an exponential decay model in calculating an accurate time course and estimation of the eventual outcome.A retrospective review of 34 patients with PAs who received adjuvant CK SRS between 2006 and 2013 was performed. Tumor volume was calculated using the planimetric method. The percent change in tumor volume and tumor volume rate of change were compared at median 4-, 10-, 20-, and 36-month intervals. Tumor responses were classified as: progression for >15% volume increase, regression for ≤15% decrease, and stabilization for ±15% of the baseline volume at the time of last follow-up. For each patient, the volumetric change versus time was fitted with an exponential model.The overall tumor control rate was 94.1% in the 36-month (range 18-87 months) follow-up period (mean volume change of -43.3%). Volume regression (mean decrease of -50.5%) was demonstrated in 27 (79%) patients, tumor stabilization (mean change of -3.7%) in 5 (15%) patients, and tumor progression (mean increase of 28.1%) in 2 (6%) patients (P = 0.001). Tumors that eventually regressed or stabilized had a temporary volume increase of 1.07% and 41.5% at 4 months after CK SRS, respectively (P = 0.017). The tumor volume estimated using the exponential fitting equation demonstrated high positive correlation with the actual volume calculated by magnetic resonance imaging (MRI) as tested by Pearson correlation coefficient (0.9).Transient progression of PAs post-CK SRS was seen in 62.5% of the patients receiving CK SRS, and it was not predictive of eventual volume regression or progression. A three-point exponential model is of potential predictive value according to relative distribution. An exponential decay model can be used to calculate the time course of tumors that are ultimately controlled.
Narayanasamy, Ganesh; Smith, Adam; Van Meter, Emily; McGarry, Ronald; Molloy, Janelle A.
2013-01-01
Purpose: To assess the hypothesis that the volume of whole brain that receives a certain dose level is primarily dependent on the treated volume rather than on the number, shape, or location of the lesions. This would help a physician validate the suitability of GammaKnife® based stereotactic radiosurgery (GKSR) prior to treatment. Methods: Simulation studies were performed to establish the hypothesis for both oblong and spherical shaped lesions of various numbers and sizes. Forty patients who underwent GKSR [mean age of 54 years (range 7–80), mean number of lesions of 2.5 (range 1–6), and mean lesion volume of 4.4 cm3 (range 0.02–22.2 cm3)] were also studied retrospectively. Following recommendations of QUANTEC, the volume of brain irradiated by the 12 Gy (VB12) isodose line was measured and a power-law based relation is proposed here for estimating VB12 from the known tumor volume and the prescription dose. Results: In the simulation study on oblong, spherical, and multiple lesions, the volume of brain irradiated by 50%, 10%, and 1% of maximum dose was found to have linear, linear, and exponentially increasing dependence on the volume of the treated region, respectively. In the retrospective study on 40 GKSR patients, a similar relationship was found to predict the brain dose with a Spearman correlation coefficient >0.9. In both the studies, the volume of brain irradiated by a certain dose level does not have a statistically significant relationship (p ≥ 0.05) with the number, shape, or position of the lesions. The measured VB12 agrees with calculation to within 1.7%. Conclusions: The results from the simulation and the retrospective clinical studies indicate that the volume of whole brain that receives a certain percentage of the maximum dose is primarily dependent on the treated volume and less on the number, shape, and location of the lesions. PMID:24007147
Dahshan, Basem A; Mattes, Malcolm D; Bhatia, Sanjay; Palek, Mary Susan; Cifarelli, Christopher P; Hack, Joshua D; Vargo, John A
2017-12-19
The role of stereotactic radiosurgery (SRS) in the treatment of multiple brain metastases is controversial. While whole brain radiation therapy (WBRT) has historically been the mainstay of treatment, its value is increasingly being questioned as emerging data supports that SRS alone can provide comparable therapeutic outcomes for limited (one to three) intracranial metastases with fewer adverse effects, including neurocognitive decline. Multiple recent studies have also demonstrated that patients with multiple (> 3) intracranial metastases with a low overall tumor volume have a favorable therapeutic response to SRS, with no significant difference compared to patients with limited metastases. Herein, we present a patient with previously controlled breast cancer who presented with multiple recurrences of intracranial metastases but low total intracranial tumor volume each time. This patient underwent SRS alone for a total of 40 metastatic lesions over three separate procedures with good local control and without any significant cognitive toxicity. The patient eventually opted for enrollment in the NRG-CC001 clinical trial after multiple cranial recurrences. She received conventional WBRT with six months of memantine and developed significant neurocognitive side effects. This case highlights the growing body of literature supporting the role of SRS alone in the management of multiple brain metastases and the importance of maximizing neurocognition as advances in systemic therapies prolong survival in Stage IV cancer.
Mattes, Malcolm D; Bhatia, Sanjay; Palek, Mary Susan; Cifarelli, Christopher P; Hack, Joshua D; Vargo, John A
2017-01-01
The role of stereotactic radiosurgery (SRS) in the treatment of multiple brain metastases is controversial. While whole brain radiation therapy (WBRT) has historically been the mainstay of treatment, its value is increasingly being questioned as emerging data supports that SRS alone can provide comparable therapeutic outcomes for limited (one to three) intracranial metastases with fewer adverse effects, including neurocognitive decline. Multiple recent studies have also demonstrated that patients with multiple (> 3) intracranial metastases with a low overall tumor volume have a favorable therapeutic response to SRS, with no significant difference compared to patients with limited metastases. Herein, we present a patient with previously controlled breast cancer who presented with multiple recurrences of intracranial metastases but low total intracranial tumor volume each time. This patient underwent SRS alone for a total of 40 metastatic lesions over three separate procedures with good local control and without any significant cognitive toxicity. The patient eventually opted for enrollment in the NRG-CC001 clinical trial after multiple cranial recurrences. She received conventional WBRT with six months of memantine and developed significant neurocognitive side effects. This case highlights the growing body of literature supporting the role of SRS alone in the management of multiple brain metastases and the importance of maximizing neurocognition as advances in systemic therapies prolong survival in Stage IV cancer. PMID:29492355
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jia, J; Tian, Z; Gu, X
2014-06-15
Purpose: We studied dosimetric effects of inter-fraction deformation in lung stereotactic body radiotherapy (SBRT), in order to investigate the necessity of adaptive re-planning for lung SBRT treatments. Methods: Six lung cancer patients with different treatment fractions were retrospectively investigated. All the patients were immobilized and localized with a stereotactic body frame and were treated under cone-beam CT (CBCT) image guidance at each fraction. We calculated the actual delivered dose of the treatment plan using the up-to-date patient geometry of each fraction, and compared the dose with the intended plan dose to investigate the dosimetric effects of the inter-fraction deformation. Deformablemore » registration was carried out between the treatment planning CT and the CBCT of each fraction to obtain deformed planning CT for more accurate dose calculations of the delivered dose. The extent of the inter-fraction deformation was also evaluated by calculating the dice similarity coefficient between the delineated structures on the planning CT and those on the deformed planning CT. Results: The average dice coefficients for PTV, spinal cord, esophagus were 0.87, 0.83 and 0.69, respectively. The volume of PTV covered by prescription dose was decreased by 23.78% on average for all fractions and all patients. For spinal cord and esophagus, the volumes covered by the constraint dose were increased by 4.57% and 3.83%. The maximum dose was also increased by 4.11% for spinal cord and 4.29% for esophagus. Conclusion: Due to inter-fraction deformation, large deterioration was found in both PTV coverage and OAR sparing, which demonstrated the needs for adaptive re-planning of lung SBRT cases to improve target coverage while reducing radiation dose to nearby normal tissues.« less
2010-01-01
by the Institutional Animal Care and Use Committee and all animals received humane care in com- pliance with the Guide for the Care and Use of...diminished markedly in recent military operations, due to sev- eral factors including routine vi-ear of hody armor, judicious use of tourniquets for...extremity hemorrhage, rapid casualty evacuation, and aggressive use of blood products in hemor- rhagic shock.’’ Advanced hemostatic agents further reduce
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molla, Meritxell; Escude, Lluis D.; Nouet, Philippe
2005-05-01
Purpose: A brachytherapy (BT) boost to the vaginal vault is considered standard treatment for many endometrial or cervical cancers. We aimed to challenge this treatment standard by using stereotactic radiotherapy (SRT) with a linac-based micromultileaf collimator technique. Methods and Materials: Since January 2002, 16 patients with either endometrial (9) or cervical (7) cancer have been treated with a final boost to the areas at higher risk for relapse. In 14 patients, the target volume included the vaginal vault, the upper vagina, the parametria, or (if not operated) the uterus (clinical target volume [CTV]). In 2 patients with local relapse, themore » CTV was the tumor in the vaginal stump. Margins of 6-10 mm were added to the CTV to define the planning target volume (PTV). Hypofractionated dynamic-arc or intensity-modulated radiotherapy techniques were used. Postoperative treatment was delivered in 12 patients (2 x 7 Gy to the PTV with a 4-7-day interval between fractions). In the 4 nonoperated patients, a dose of 4 Gy/fraction in 5 fractions with 2 to 3 days' interval was delivered. Patients were immobilized in a customized vacuum body cast and optimally repositioned with an infrared-guided system developed for extracranial SRT. To further optimize daily repositioning and target immobilization, an inflated rectal balloon was used during each treatment fraction. In 10 patients, CT resimulation was performed before the last boost fraction to assess for repositioning reproducibility via CT-to-CT registration and to estimate PTV safety margins around the CTV. Finally, a comparative treatment planning study between BT and SRT was performed in 2 patients with an operated endometrial Stage I cancer. Results: No patient developed severe acute urinary or low-intestinal toxicity. No patient developed urinary late effects (>6 months). One patient with a vaginal relapse previously irradiated to the pelvic region presented with Grade 3 rectal bleeding 18 months after retreatment. A second patient known to suffer from irritable bowel syndrome presented with Grade 1 abdominal pain after treatment. The estimated PTV margins around the CTV were 9-10 mm with infrared marker registration. External SRT succeeded in improving dose homogeneity to the PTV and in reducing the maximum dose to the rectum, when compared to BT. Conclusion: These results suggest that the use of external SRT to deliver a final boost to the areas at higher risk for relapse in endometrial or cervical cancer is feasible, well tolerated, and may well be considered an acceptable alternative to BT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Wensha, E-mail: wensha.yang@cshs.org; Reznik, Robert; Fraass, Benedick A.
Stereotactic body radiation therapy (SBRT) provides a promising way to treat locally advanced pancreatic cancer and borderline resectable pancreatic cancer. A simultaneous integrated boost (SIB) to the region of vessel abutment or encasement during SBRT has the potential to downstage otherwise likely positive surgical margins. Despite the potential benefit of using SIB-SBRT, the ability to boost is limited by the local geometry of the organs at risk (OARs), such as stomach, duodenum, and bowel (SDB), relative to tumor. In this study, we have retrospectively replanned 20 patients with 25 Gy prescribed to the planning target volume (PTV) and 33~80 Gymore » to the boost target volume (BTV) using an SIB technique for all patients. The number of plans and patients able to satisfy a set of clinically established constraints is analyzed. The ability to boost vessels (within the gross target volume [GTV]) is shown to correlate with the overlap volume (OLV), defined to be the overlap between the GTV + a 1(OLV1)- or 2(OLV2)-cm margin with the union of SDB. Integral dose, boost dose contrast (BDC), biologically effective BDC, tumor control probability for BTV, and normal tissue complication probabilities are used to analyze the dosimetric results. More than 65% of the cases can deliver a boost to 40 Gy while satisfying all OAR constraints. An OLV2 of 100 cm{sup 3} is identified as the cutoff volume: for cases with OLV2 larger than 100 cm{sup 3}, it is very unlikely the case could achieve 25 Gy to the PTV while successfully meeting all the OAR constraints.« less
Dose gradient curve: A new tool for evaluating dose gradient
Choi, Young Eun
2018-01-01
Purpose Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. Methods The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Results Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. Conclusions The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice. PMID:29698471
Karava, Konstantina; Ehrbar, Stefanie; Riesterer, Oliver; Roesch, Johannes; Glatz, Stefan; Klöck, Stephan; Guckenberger, Matthias; Tanadini-Lang, Stephanie
2017-11-09
Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langenberg, Rick van de, E-mail: rickvandelangenberg@hotmail.com; Dohmen, Amy J.C.; Bondt, Bert J. de
2012-10-01
Purpose: The purpose of this study was to evaluate the control rate of vestibular schwannomas (VS) after treatment with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) or radiotherapy (SRT) by using a validated volumetric measuring tool. Volume-based studies on prognosis after LINAC-based SRS or SRT for VS are reported scarcely. In addition, growth patterns and risk factors predicting treatment failure were analyzed. Materials and Methods: Retrospectively, 37 VS patients treated with LINAC based SRS or SRT were analyzed. Baseline and follow-up magnetic resonance imaging scans were analyzed with volume measurements on contrast enhanced T1-weighted magnetic resonance imaging. Absence of intervention aftermore » radiotherapy was defined as 'no additional intervention group, ' absence of radiological growth was defined as 'radiological control group. ' Significant growth was defined as a volume change of 19.7% or more, as calculated in a previous study. Results: The cumulative 4-year probability of no additional intervention was 96.4% {+-} 0.03; the 4-year radiological control probability was 85.4% {+-} 0.1). The median follow-up was 40 months. Overall, shrinkage was seen in 65%, stable VS in 22%, and growth in 13%. In 54% of all patients, transient swelling was observed. No prognostic factors were found regarding VS growth. Previous treatment and SRS were associated with transient swelling significantly. Conclusions: Good control rates are reported for LINAC based SRS or SRT in VS, in which the lower rate of radiological growth control is attributed to the use of the more sensitive volume measurements. Transient swelling after radiosurgery is a common phenomenon and should not be mistaken for treatment failure. Previous treatment and SRS were significantly associated with transient swelling.« less
Yang, Wensha; Reznik, Robert; Fraass, Benedick A; Nissen, Nicholas; Hendifar, Andrew; Wachsman, Ashley; Sandler, Howard; Tuli, Richard
2015-01-01
Stereotactic body radiation therapy (SBRT) provides a promising way to treat locally advanced pancreatic cancer and borderline resectable pancreatic cancer. A simultaneous integrated boost (SIB) to the region of vessel abutment or encasement during SBRT has the potential to downstage otherwise likely positive surgical margins. Despite the potential benefit of using SIB-SBRT, the ability to boost is limited by the local geometry of the organs at risk (OARs), such as stomach, duodenum, and bowel (SDB), relative to tumor. In this study, we have retrospectively replanned 20 patients with 25Gy prescribed to the planning target volume (PTV) and 33~80Gy to the boost target volume (BTV) using an SIB technique for all patients. The number of plans and patients able to satisfy a set of clinically established constraints is analyzed. The ability to boost vessels (within the gross target volume [GTV]) is shown to correlate with the overlap volume (OLV), defined to be the overlap between the GTV + a 1(OLV1)- or 2(OLV2)-cm margin with the union of SDB. Integral dose, boost dose contrast (BDC), biologically effective BDC, tumor control probability for BTV, and normal tissue complication probabilities are used to analyze the dosimetric results. More than 65% of the cases can deliver a boost to 40Gy while satisfying all OAR constraints. An OLV2 of 100cm(3) is identified as the cutoff volume: for cases with OLV2 larger than 100cm(3), it is very unlikely the case could achieve 25Gy to the PTV while successfully meeting all the OAR constraints. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wan, Shuying; Oliver, Michael; Wang, Xiaofang
2014-08-15
Stereotactic body radiation therapy (SBRT), due to its high precision for target localizing, has become widely used to treat tumours at various locations, including the lungs. Lung SBRT program was started at our institution a year ago. Eighteen patients with peripheral lesions up to 3 cm diameter have been treated with 48 Gy in 4 fractions. Based on four-dimensional computed tomography (4DCT) simulation, internal target volume (ITV) was delineated to encompass the respiratory motion of the lesion. A margin of 5 mm was then added to create the planning target volume (PTV) for setup uncertainties. There was no expansion frommore » gross tumour volume (GTV) to clinical target volume (CTV). Pinnacle 9.6 was used as the primary treatment planning system. Volumetric modulated arc therapy (VMAT) technique, with one or two coplanar arcs, generally worked well. For quality assurance (QA), each plan was exported to Eclipse 10 and dose calculation was repeated. Dose volume histograms (DVHs) of the targets and organs at risk (OARs) were then compared between the two treatment planning systems. Winston-Lutz tests were carried out as routine machine QA. Patient-specific QA included ArcCheck measurement with an insert, where an ionization chamber was placed at the centre to measure dose at the isocenter. For the first several patients, and subsequently for the plans with extremely strong modulation, Gafchromic film dosimetry was also employed. For each patient, a mock setup was scheduled prior to treatments. Daily pre- and post-CBCT were acquired for setup and assessment of intra-fractional motion, respectively.« less
Madhavan, R; Renilmon, P S; Nair, H M; Lal, A; Nair, S S; Unnikrishnan, U G; Makuny, D
2017-01-01
The hypofractionated stereotactic body radiation therapy (SBRT) has emerged as a safe and effective treatment modality for early-stage nonsmall cell lung carcinoma. An audit SBRT in primary lung cancer treated in our center with and without an active breath coordinator (ABC) was undertaken to evaluate its impact on target volumes and clinical outcomes. This was an observational study. Nine patients with lung carcinoma were treated from January 2014 to August 2016. Five patients were simulated using ABC and four patients with free breathing. Volumetric modulated arc therapy plans were generated using Monaco treatment planning software. Three patients were treated with a dose of 54 Gy in three fractions and six patients with a dose of 48 Gy in four fractions. The statistical analysis was performed using Kaplan-Meier survival. The mean planning target volumes (PTV) in ABC and free breathing groups were 42.19cc and 60.17cc, respectively. The mean volume of lung receiving 20, 10, and 5 Gy (V20, V10and V5) in ABC group were 5.37cc, 10.49cc, and 18.45cc whereas in free breathing 6.63cc, 12.74cc, and 20.64cc, respectively. At a median follow-up of 18 months, there were three local recurrences. No significant toxicity occurred in our series. Our initial results show that SBRT is well tolerated with good local control. Although the PTV volume and irradiated normal lung volume was higher in this group compared to ABC group, this did not translate to any added clinical toxicity.
NASA Astrophysics Data System (ADS)
Dang, Hao; Webster Stayman, J.; Sisniega, Alejandro; Zbijewski, Wojciech; Xu, Jennifer; Wang, Xiaohui; Foos, David H.; Aygun, Nafi; Koliatsos, Vassilis E.; Siewerdsen, Jeffrey H.
2017-01-01
A prototype cone-beam CT (CBCT) head scanner featuring model-based iterative reconstruction (MBIR) has been recently developed and demonstrated the potential for reliable detection of acute intracranial hemorrhage (ICH), which is vital to diagnosis of traumatic brain injury and hemorrhagic stroke. However, data truncation (e.g. due to the head holder) can result in artifacts that reduce image uniformity and challenge ICH detection. We propose a multi-resolution MBIR method with an extended reconstruction field of view (RFOV) to mitigate truncation effects in CBCT of the head. The image volume includes a fine voxel size in the (inner) nontruncated region and a coarse voxel size in the (outer) truncated region. This multi-resolution scheme allows extension of the RFOV to mitigate truncation effects while introducing minimal increase in computational complexity. The multi-resolution method was incorporated in a penalized weighted least-squares (PWLS) reconstruction framework previously developed for CBCT of the head. Experiments involving an anthropomorphic head phantom with truncation due to a carbon-fiber holder were shown to result in severe artifacts in conventional single-resolution PWLS, whereas extending the RFOV within the multi-resolution framework strongly reduced truncation artifacts. For the same extended RFOV, the multi-resolution approach reduced computation time compared to the single-resolution approach (viz. time reduced by 40.7%, 83.0%, and over 95% for an image volume of 6003, 8003, 10003 voxels). Algorithm parameters (e.g. regularization strength, the ratio of the fine and coarse voxel size, and RFOV size) were investigated to guide reliable parameter selection. The findings provide a promising method for truncation artifact reduction in CBCT and may be useful for other MBIR methods and applications for which truncation is a challenge.
Schad, L R; Boesecke, R; Schlegel, W; Hartmann, G H; Sturm, V; Strauss, L G; Lorenz, W J
1987-01-01
A treatment planning system for stereotactic convergent beam irradiation of deeply localized brain tumors is reported. The treatment technique consists of several moving field irradiations in noncoplanar planes at a linear accelerator facility. Using collimated narrow beams, a high concentration of dose within small volumes with a dose gradient of 10-15%/mm was obtained. The dose calculation was based on geometrical information of multiplanar CT or magnetic resonance (MR) imaging data. The patient's head was fixed in a stereotactic localization system, which is usable at CT, MR, and positron emission tomography (PET) installations. Special computer programs for correction of the geometrical MR distortions allowed a precise correlation of the different imaging modalities. The therapist can use combinations of CT, MR, and PET data for defining target volume. For instance, the superior soft tissue contrast of MR coupled with the metabolic features of PET may be a useful addition in the radiation treatment planning process. Furthermore, other features such as calculated dose distribution to critical structures can also be transferred from one set of imaging data to another and can be displayed as three-dimensional shaded structures.
Raya, Amanda; Zipfel, Gregory J; Diringer, Michael N; Dacey, Ralph G; Derdeyn, Colin P; Rich, Keith M; Chicoine, Michael R; Dhar, Rajat
2014-01-01
Spontaneous idiopathic subarachnoid hemorrhage (SAH) with a perimesencephalic bleeding pattern is usually associated with a benign course, whereas a diffuse bleeding pattern has been associated with a higher risk of vasospasm and disability. We evaluated whether volume of bleeding explains this disparity. Pattern and amount of bleeding (by Hijdra and intraventricular hemorrhage scores) were assessed in 89 patients with nonaneurysmal SAH. Outcomes included angiographic vasospasm, delayed cerebral ischemia, and functional outcome at 1 year. Diffuse bleeding was associated with significantly higher Hijdra and intraventricular hemorrhage scores than perimesencephalic SAH, P≤0.003. Angiographic vasospasm was more likely in diffuse versus perimesencephalic SAH (45% versus 27%; odds ratio, 2.9; P=0.08), but adjustment for greater blood burden only partially attenuated this trend (adjusted odds ratio, 2.2; 95% confidence interval, 0.69-7.2; P=0.18); delayed cerebral ischemia was only seen in those with diffuse bleeding. Patients with diffuse bleeding were less likely to be discharged home (68% versus 90%; P=0.01) and tended to have more residual disability (modified Rankin scale, 3-6; 20% versus 6%; P=0.18). Nonaneurysmal SAH can still result in vasospasm and residual disability, especially in those with diffuse bleeding. This disparity is only partially accounted for by greater cisternal or intraventricular blood, suggesting that the mechanism and distribution of bleeding may be as important as the amount of hemorrhage in patients with idiopathic SAH.
Yamada, Kiyofumi; Song, Yan; Hippe, Daniel S; Sun, Jie; Dong, Li; Xu, Dongxiang; Ferguson, Marina S; Chu, Baocheng; Hatsukami, Thomas S; Chen, Min; Zhou, Cheng; Yuan, Chun
2012-11-29
Carotid intraplaque hemorrhage (IPH) and lipid rich necrotic core (LRNC) have been associated with accelerated plaque growth, luminal narrowing, future surface disruption and development of symptomatic events. The aim of this study was to evaluate the quantitative relationships between high intensity signals (HIS) in the plaque on TOF-MRA and IPH or LRNC volumes as measured by multicontrast weighted CMR. Seventy six patients with a suspected carotid artery stenosis or carotid plaque by ultrasonography underwent multicontrast carotid CMR. HIS presence and volume were measured from TOF-MRA MIP images while IPH and LRNC volumes were separately measured from multicontrast CMR. For detecting IPH, HIS on MIP images overall had high specificity (100.0%, 95% CI: 93.0 - 100.0%) but relatively low sensitivity (32%, 95% CI: 20.8 - 47.9%). However, the sensitivity had a significant increasing relationship with underlying IPH volume (p = 0.033) and degree of stenosis (p = 0.022). Mean IPH volume was 2.7 times larger in those with presence of HIS than in those without (142.8 ± 97.7 mm(3) vs. 53.4 ± 56.3 mm(3), p = 0.014). Similarly, mean LRNC volume was 3.4 times larger in those with HIS present (379.8 ± 203.4 mm(3) vs. 111.3 ± 122.7 mm(3), p = 0.001). There was a strong correlation between the volume of the HIS region and the IPH volume measured from multicontrast CMR (r = 0.96, p < 0.001). MIP images are easily reformatted from three minute, routine, clinical TOF sequences. High intensity signals in carotid plaque on TOF-MRA MIP images are associated with increased intraplaque hemorrhage and lipid-rich necrotic core volumes. The technique is most sensitive in patients with moderate to severe stenosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Ryan; Han Gang; Sarangkasiri, Siriporn
2013-01-01
Purpose: To report clinical and dosimetric factors predictive of radiation pneumonitis (RP) in patients receiving lung stereotactic body radiation therapy (SBRT) from a series of 240 patients. Methods and Materials: Of the 297 isocenters treating 263 patients, 240 patients (n=263 isocenters) had evaluable information regarding RP. Age, gender, current smoking status and pack-years, O{sub 2} use, Charlson Comorbidity Index, prior lung radiation therapy (yes/no), dose/fractionation, V{sub 5}, V{sub 13}, V{sub 20}, V{sub prescription}, mean lung dose, planning target volume (PTV), total lung volume, and PTV/lung volume ratio were recorded. Results: Twenty-nine patients (11.0%) developed symptomatic pneumonitis (26 grade 2, 3more » grade 3). The mean V{sub 20} was 6.5% (range, 0.4%-20.2%), and the average mean lung dose was 5.03 Gy (0.547-12.2 Gy). In univariable analysis female gender (P=.0257) and Charlson Comorbidity index (P=.0366) were significantly predictive of RP. Among dosimetric parameters, V{sub 5} (P=.0186), V{sub 13} (P=.0438), and V{sub prescription} (where dose = 60 Gy) (P=.0128) were significant. There was only a trend toward significance for V{sub 20} (P=.0610). Planning target volume/normal lung volume ratio was highly significant (P=.0024). In multivariable analysis the clinical factors of female gender, pack-years smoking, and larger gross internal tumor volume and PTV were predictive (P=.0094, .0312, .0364, and .052, respectively), but no dosimetric factors were significant. Conclusions: Rate of symptomatic RP was 11%. Our mean lung dose was <600 cGy in most cases and V20 <10%. In univariable analysis, dosimetric factors were predictive, while tumor size (or tumor/lung volume ratio) played a role in multivariable and univariable and analysis, respectively.« less
Association of subdural hematoma with increased mortality in lobar intracerebral hemorrhage.
Patel, Pratik V; FitzMaurice, Emilie; Nandigam, R N Kaveer; Auluck, Pavan; Viswanathan, Anand; Goldstein, Joshua N; Rosand, Jonathan; Greenberg, Steven M; Smith, Eric E
2009-01-01
To determine the prevalence of subdural hematoma (SDH) in patients presenting with primary nontraumatic lobar intracerebral hemorrhage (ICH) and characteristics associated with the presence of SDH. Retrospective analysis of data collected in a prospective cohort study. Hospital. Consecutive sample of 200 patients with primary lobar ICH and 75 patients with deep hemispheric ICH. Presence of SDH and mortality. Subdural hematoma was present in 40 of 200 patients (20%) with primary lobar ICH. By contrast, SDH was not present in any of 75 consecutive patients with deep hemispheric ICH (P < .001 for comparison with lobar ICH). Intracerebral hemorrhage volume higher than 60 cm3 was the only independent predictor of SDH (odds ratio [OR], 2.69; 95% confidence interval [CI], 1.14-6.34; P = .02). Subdural hematoma thickness more than 5 mm was an independent predictor of increased 30-day mortality (OR, 7.60; 95% CI, 1.86-30.99; P = .005) after controlling for other factors including ICH volume. Further analysis showed that the effect of SDH on mortality depended on ICH volume, with larger odds for mortality in those with low ICH volume (OR, 12.85; 95% CI, 2.42-68.23; P = .003 for those with ICH volume <30 cm3). Cerebral amyloid angiopathy was present in 8 of 9 patients with pathological specimens. Nontraumatic SDH frequently accompanies primary lobar ICH and is associated with higher 30-day mortality, particularly when the ICH volume is relatively low. Rupture of an amyloid-laden leptomeningeal vessel, with extravasation into the brain parenchyma and subdural space, may be the pathogenic mechanism.
Reperfusion-Associated Hemorrhagic Transformation in SHR Rats
Henning, Erica C.; Latour, Lawrence L.; Hallenbeck, John M.; Warach, Steven
2016-01-01
Background and Purpose Symptomatic hemorrhagic transformation (HT) is the most important complicating factor after treatment with intravenous tissue plasminogen activator. In this study, we used multimodal magnetic resonance imaging to investigate the incidence and severity of reperfusion-based HT in spontaneously hypertensive rats after ischemia/reperfusion. Methods Twenty male spontaneously hypertensive rats were subjected to 30 minutes of middle cerebral artery occlusion via the suture model. Diffusion-weighted, T2-weighted, and gradient-echo imaging were performed on days 1, 2, 3, 4, and 7 for longitudinal evaluation of lesion evolution, vasogenic edema, and HT, respectively. Findings on gradient-echo images were classified according to the severity of hemorrhage: no HT; punctate or small petechial hemorrhage (HI-1); confluent petechial hemorrhage (HI-2); hematoma with absent/mild space-occupying effect (PH-1, ≤30% lesion volume); and hematoma with significant space-occupying effect and potential perihematomal edema (PH-2, >30% lesion volume). Histopathologic evaluation of HT was performed after final imaging for comparison with magnetic resonance imaging results. Results Final hemorrhage scores based on severity were as follows: HI-1 23.1%, HI-2 30.8%, PH-1 30.8%, and PH-2 15.4%. Similar to clinical observations, only PH-2 was associated with neurologic deterioration and associated weight loss. Conclusions This model has a high incidence of parenchymal hematomas (46.2%) and therefore is appropriate for the evaluation of novel therapeutics targeting blood-brain barrier integrity and the reduction of symptomatic HT events (PH-2), as well as those potentially “at risk” for neurologic deterioration (PH-1). PMID:18757286
Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H
1998-01-01
To determine whether prolonged (chronic) resuscitation has any beneficial effects on cardiac output and hepatocellular function after trauma-hemorrhage and acute fluid replacement. Acute fluid resuscitation after trauma-hemorrhage restores but does not maintain the depressed hepatocellular function and cardiac output. Male Sprague-Dawley rats underwent a 5-cm laparotomy (i.e., trauma was induced) and were bled to and maintained at a mean arterial pressure of 40 mmHg until 40% of maximal bleed-out volume was returned in the form of Ringer's lactate (RL). The animals were acutely resuscitated with RL using 4 times the volume of maximum bleed-out over 60 minutes, followed by chronic resuscitation of 0, 5, or 10 mL/kg/hr RL for 20 hours. Hepatocellular function was determined by an in vivo indocyanine green clearance technique. Hepatic microvascular blood flow was assessed by laser Doppler flowmetry. Plasma levels of interleukin-6 (IL-6) were determined by bioassay. Chronic resuscitation with 5 mL/kg/hr RL, but not with 0 or 10 mL/kg/hr RL, restored cardiac output, hepatocellular function, and hepatic microvascular blood flow at 20 hours after hemorrhage. The regimen above also reduced plasma IL-6 levels. Because chronic resuscitation with 5 mL/kg/hr RL after trauma-hemorrhage and acute fluid replacement restored hepatocellular function and hepatic microvascular blood flow and decreased plasma levels of IL-6, we propose that chronic fluid resuscitation in addition to acute fluid replacement should be routinely used in experimental studies of trauma-hemorrhage.
Franzese, Ciro; Lopci, Egesta; Di Brina, Lucia; D'Agostino, Giuseppe Roberto; Navarria, Pierina; Mancosu, Pietro; Tomatis, Stefano; Chiti, Arturo; Scorsetti, Marta
2017-10-21
aim is outcome of 11C-Choline-PET guided SBRT on lymph node metastases. patients with 1 - 4 lymph node metastases detected by 11C-choline-PET were treated with SBRT. Toxicity, treated metastases control and Progression Free Survival were computed. twenty-six patients, 38 lymph node metastases were irradiated. No grade ≥ 2 toxicity. Median PSA-nadir after RT was 1.02 ng/mL. Post-treatment 11C-Choline-PET showed metabolic complete response in 17 metastases (44,7%), partial response in 9 metastases (38%). SBRT is effective and safe for lymph node metastases. PET is important in identification of gross tumor and evaluation of the response.
Glibenclamide for the treatment of ischemic and hemorrhagic stroke.
Caffes, Nicholas; Kurland, David B; Gerzanich, Volodymyr; Simard, J Marc
2015-03-04
Ischemic and hemorrhagic strokes are associated with severe functional disability and high mortality. Except for recombinant tissue plasminogen activator, therapies targeting the underlying pathophysiology of central nervous system (CNS) ischemia and hemorrhage are strikingly lacking. Sur1-regulated channels play essential roles in necrotic cell death and cerebral edema following ischemic insults, and in neuroinflammation after hemorrhagic injuries. Inhibiting endothelial, neuronal, astrocytic and oligodendroglial sulfonylurea receptor 1-transient receptor potential melastatin 4 (Sur1-Trpm4) channels and, in some cases, microglial KATP (Sur1-Kir6.2) channels, with glibenclamide is protective in a variety of contexts. Robust preclinical studies have shown that glibenclamide and other sulfonylurea agents reduce infarct volumes, edema and hemorrhagic conversion, and improve outcomes in rodent models of ischemic stroke. Retrospective studies suggest that diabetic patients on sulfonylurea drugs at stroke presentation fare better if they continue on drug. Additional laboratory investigations have implicated Sur1 in the pathophysiology of hemorrhagic CNS insults. In clinically relevant models of subarachnoid hemorrhage, glibenclamide reduces adverse neuroinflammatory and behavioral outcomes. Here, we provide an overview of the preclinical studies of glibenclamide therapy for CNS ischemia and hemorrhage, discuss the available data from clinical investigations, and conclude with promising preclinical results that suggest glibenclamide may be an effective therapeutic option for ischemic and hemorrhagic stroke.
Williamson, Michael R; Colbourne, Frederick
2017-08-01
Potentially fatal intracranial pressure (ICP) rises commonly occur after large intracerebral hemorrhages (ICH). We monitored ICP after infusing 100-160 μL of autologous blood (vs. 0 μL control) into the striatum of rats in order to test the validity of this common model with regard to ICP elevations. Other endpoints included body temperature, behavioral impairment, lesion volume, and edema. Also, we evaluated hippocampal CA1 sector and somatosensory cortical neuron morphology to assess whether global ischemic injury occurred. Despite massive blood infusions, ICP only modestly increased (160 μL 10.8 ± 2.1 mmHg for <36 h vs. control 3.4 ± 0.5 mmHg), with little peri-hematoma edema at 3 days. Body temperature was not affected. Behavioral deficits and tissue loss were infusion volume-dependent. There was no histological evidence of hippocampal or cortical injury, indicating that cell death was confined to the hematoma and closely surrounding tissue. Surprisingly, the most severe hemorrhages significantly increased cell density (~15-20%) and reduced cell body size (~30%) in regions outside the injury site. Additionally, decreased cell size and increased density were observed after collagenase-induced ICH. Parenchymal volume is seemingly reduced after large ICH. Thus, in addition to well-known compliance mechanisms (e.g., displacement of cerebrospinal fluid and cerebral blood), reduced brain parenchymal volume appears to limit ICP rises in rodents with very large mass lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anker, Christopher J., E-mail: chris.anker@UVMHealth.org; Grossmann, Kenneth F.; Atkins, Michael B.
2016-06-01
BRAF kinase gene V600 point mutations drive approximately 40% to 50% of all melanomas, and BRAF inhibitors (BRAFi) have been found to significantly improve survival outcomes. Although radiation therapy (RT) provides effective symptom palliation, there is a lack of toxicity and efficacy data when RT is combined with BRAFi, including vemurafenib and dabrafenib. This literature review provides a detailed analysis of potential increased dermatologic, pulmonary, neurologic, hepatic, esophageal, and bowel toxicity from the combination of BRAFi and RT for melanoma patients described in 27 publications. Despite 7 publications noting potential intracranial neurotoxicity, the rates of radionecrosis and hemorrhage from wholemore » brain RT (WBRT), stereotactic radiosurgery (SRS), or both do not appear increased with concurrent or sequential administration of BRAFis. Almost all grade 3 dermatitis reactions occurred when RT and BRAFi were administered concurrently. Painful, disfiguring nondermatitis cutaneous reactions have been described from concurrent or sequential RT and BRAFi administration, which improved with topical steroids and time. Visceral toxicity has been reported with RT and BRAFi, with deaths possibly related to bowel perforation and liver hemorrhage. Increased severity of radiation pneumonitis with BRAFi is rare, but more concerning was a potentially related fatal pulmonary hemorrhage. Conversely, encouraging reports have described patients with leptomeningeal spread and unresectable lymphadenopathy rendered disease free from combined RT and BRAFi. Based on our review, the authors recommend holding RT ≥3 days before and after fractionated RT and ≥1 day before and after SRS. No fatal reactions have been described with a dose <4 Gy per fraction, and time off systemic treatment should be minimized. Future prospective data will serve to refine these recommendations.« less
Anker, Christopher J.; Grossmann, Kenneth F.; Atkins, Michael B.; Suneja, Gita; Tarhini, Ahmad A.; Kirkwood, John M.
2016-01-01
BRAF kinase gene V600 point mutations drive approximately 40% to 50% of all melanomas, and BRAF inhibitors (BRAFi) have been found to significantly improve survival outcomes. Although radiation therapy (RT) provides effective symptom palliation, there is a lack of toxicity and efficacy data when RT is combined with BRAFi, including vemurafenib and dabrafenib. This literature review provides a detailed analysis of potential increased dermatologic, pulmonary, neurologic, hepatic, esophageal, and bowel toxicity from the combination of BRAFi and RT for melanoma patients described in 27 publications. Despite 7 publications noting potential intracranial neurotoxicity, the rates of radionecrosis and hemorrhage from whole brain RT (WBRT), stereotactic radiosurgery (SRS), or both do not appear increased with concurrent or sequential administration of BRAFis. Almost all grade 3 dermatitis reactions occurred when RT and BRAFi were administered concurrently. Painful, disfiguring nondermatitis cutaneous reactions have been described from concurrent or sequential RT and BRAFi administration, which improved with topical steroids and time. Visceral toxicity has been reported with RT and BRAFi, with deaths possibly related to bowel perforation and liver hemorrhage. Increased severity of radiation pneumonitis with BRAFi is rare, but more concerning was a potentially related fatal pulmonary hemorrhage. Conversely, encouraging reports have described patients with leptomeningeal spread and unresectable lymphadenopathy rendered disease free from combined RT and BRAFi. Based on our review, the authors recommend holding BRAFi and/or MEK inhibitors ≥3 days before and after fractionated RT and ≥1 day before and after SRS. No fatal reactions have been described with a dose <4 Gy per fraction, and time off systemic treatment should be minimized. Future prospective data will serve to refine these recommendations. PMID:27131079
Zhang, Michael; Connolly, Ian D; Teo, Mario K; Yang, George; Dodd, Robert; Marks, Michael; Zuccarello, Mario; Steinberg, Gary K
2017-10-01
Classification of cerebrovascular malformations has revealed intermediary lesions that warrant further review owing to their unusual presentation and management. We present 2 cases of arteriovenous malformation (AVM) associated with a developmental venous anomaly (DVA), and discuss the efficacy of previously published management strategies. Two cases of AVMs associated with DVA were identified, and a literature search for published cases between 1980 and 2016 was conducted. Patient demographic data and clinical features were documented. In case 1, a 29-year-old female presenting with parenchymal hemorrhage and left homonymous hemianopia was found to have a right parieto-occipital AVM fed from the anterior cerebral, middle cerebral, and posterior cerebral arteries, with major venous drainage to the superior sagittal sinus. In case 2, imaging in a 34-year-old female evaluated for night tremors and incontinence revealed a left parietal AVM with venous drainage to the superior sagittal sinus. Including our 2 cases, 22 cases of coexisting AVMs and DVAs have been reported in the literature. At presentation, 68% had radiographic evidence of hemorrhage. Stereotactic radiosurgery was performed in 7 cases, embolization in 6 cases, surgical resection in 4 cases, and multimodal therapy in 5 cases. Radiography at follow-up demonstrated successful AVM obliteration in 67% of cases (12 of 18). Patients with coexisting AVMs and DVAs tend to have a hemorrhagic presentation. Contrary to traditional AVM management, in these cases it is important to preserve the draining vein via the DVA to ensure a safe, sustained circulatory outflow of the associated brain parenchyma while achieving safe AVM obliteration. Copyright © 2017 Elsevier Inc. All rights reserved.
Poca, Maria A; Martínez-Ricarte, Francisco-Ramon; Gándara, Dario F; Coscojuela, Pilar; Martínez-Sáez, Elena; Sahuquillo, Juan
2017-10-01
Stereotactic biopsy is a minimally invasive technique that allows brain tissue samples to be obtained with low risk. Classically, different techniques have been used to identify the biopsy site after surgery. To describe a technique to identify the precise location of the target in the postoperative CT scan using the injection of a low volume of air into the biopsy cannula. Seventy-five biopsies were performed in 65 adults and 10 children (40 males and 35 females, median age 51 years). Frame-based biopsy was performed in 46 patients, while frameless biopsy was performed in the remaining 29 patients. In both systems, after brain specimens had been collected and with the biopsy needle tip in the center of the target, a small volume of air (median 0.7 cm 3 ) was injected into the site. A follow-up CT scan was performed in all patients. Intracranial air in the selected target was present in 69 patients (92%). No air was observed in two patients (air volume administered in these 2 cases was below 0.7 cm 3 ), while in the remaining four patients blood content was observed in the target. The diagnostic yield in this series was 97.3%. No complications were found to be associated with intracranial air injection in any of the 75 patients who underwent this procedure. The air-injection maneuver proposed for use in stereotactic biopsies of intracranial mass lesions is a safe and reliable technique that allows the exact biopsy site to be located without any related complications.
Pasqualetti, Francesco; Panichi, Marco; Sainato, Aldo; Matteucci, Fabrizio; Galli, Luca; Cocuzza, Paola; Ferrazza, Patrizia; Coraggio, Gabriele; Pasqualetti, Giuseppe; Derosa, Lisa; Sollini, Martina; Mannelli, Lorenzo; Ortori, Simona; Monzani, Fabio; Ricci, Sergio; Greco, Carlo; Fabrini, Maria Grazia; Erba, Paola Anna
2016-01-22
A new entity of patients with recurrent prostate cancer limited to a small number of active metastatic lesions is having growing interest: the oligometastatic patients. Patients with oligometastatic disease could eventually be managed by treating all the active lesions with local therapy, i.e. either surgery or ablative stereotactic body radiotherapy. This study aims to assess the impact of [(18)F]Choline ([(18)F]FMCH) PET/CT and the use stereotactic body radiotherapy (SBRT) in patients (pts) with oligometastatic prostate cancer (PCa). Twenty-nine pts with oligometastatic PCa (≤3 synchronous active lesions detected with [(18)F]FMCHPET/CT) were treated with repeated salvage SBRT until disease progression (development of > three active synchronous metastases). Primary endpoint was systemic therapy-free survival measured from the baseline [(18)F]FMCHPET/CT. A total of 45 lesions were treated with SBRT. After a median follow-up of 11.5 months (range 3-40 months), 20 pts were still in the study and did not receive any systemic therapy. Nine pts started systemic therapy, and the median time of the primary endpoint was 39.7 months (CI 12.20-62.14 months). No grade 3 or 4 toxicity was recorded. Repeated salvage [(18)F]FMCHPET/CT-guided SBRT is well tolerated and could defer the beginning of systemic therapy in selected patients with oligometastatic PCa.
Contreras Lopez, William Omar; Azevedo, Angelo R; Cury, Rubens G; Alencar, Francisco; Neville, Iuri S; Reis, Paul R; Navarro, Jessie; Monaco, Bernardo; da Silva, Fabio E Fernandes; Teixeira, Manoel J; Fonoff, Erich T
2016-02-01
Reporting the outcome of two patients who underwent unilateral ablative stereotactic surgery to treat pharmacologic resistant posttraumatic tremor (PTT). We present two patients (31 and 47 years old) with refractory PTT severely affecting their quality of life. Under stereotactic guidance, refined by T2-weighted magnetic resonance imaging and double-channel multiunit microelectrode recording (MER), three sequential radiofrequency lesions were performed in the caudal zona incerta (cZi) up to the base of thalamus (VOP). Effects of cZi/VOP lesion were prospectively rated with a tremor rating scale. Both patients demonstrated intraoperative tremor suppression with sustained results up to 18 months follow-up, with improvement of 92% and 84%, respectively, on the tremor rating scale. Tremor improvement was associated with enhancement functionality and quality of life for the patients. The patients returned to their work after the procedure. No adverse effects were observed up to the last follow-up. Radiofrequency lesion of the cZi/VOP target was effective for posttraumatic tremor in both cases. The use of T2-weighted images and MER was found helpful in increasing the precision and safety of the procedure, because it leads the RF probe by relying on neighbor structures based on thalamus and subthalamic nucleus. Copyright © 2016 Elsevier Inc. All rights reserved.
Salgueiro, L M; Rodríguez-Acosta, A; Rivas-Vetencourt, P; Zerpa, M; Carillo, G; Aguilar, I; Girón, M E; Acevedo, C E; Gendzekhadze, K
2001-05-01
The main aim of this work was the development of a primary hepatocyte culture from Didelphis marsupialis, to determine the possible use of culture medium supernatants as a source of inhibitors of the Bothrops lanceolatus venom hemorrhagic activity. The cellular culture was carried out from isolated hepatocytes by the double perfusion technique, and digestion of the liver with collagenase and culturing the hepatocytes in a liquid media under continuous agitation at 37 degrees C in 5% CO2. The hemorrhagic activity inhibition assays were performed inoculating intradermically, a mixture of Bothrops lanceolatus venom plus a pool of liver spheroids culture supernatants, in mice. These liver Didelphis marsupialis spheroid cultures were adequate to obtain large supernatant volumes with inhibitors of hemorrhagic activity.
NASA Technical Reports Server (NTRS)
Darlington, Daniel N.; Keil, Lanny C.; Dallman, Mary F.
1989-01-01
Bilateral adrenalectomy (ADRX) in rats removes the source of two major stress-responsive hormones, corticosterone and epinephrine. To test how ADRX rats with-stand stress, we performed the following experiments in adult male rats provided with indwelling femoral arterial and venous cannulae and either ADRX or sham-adrenalectomized (Sham) 3 days later and given 0.5% NaCl to drink. Five to 6 days after adrenal surgery the rats were studied after either a 15 ml/kg.5 min hemorrhage or after an overnight fast followed by insulin-induced hypoglycemia. In fed unstressed ADRX rats, basal mean arterial blood pressure was slightly decreased; heart rate was increased; blood volume, vasopressin, and oxytocin concentrations were not different from sham values; and renin and norepinephrine were significantly elevated. The recovery of arterial pressure after hemorrhage in the ADRX rats was similar to that in the sham group over a 5-h period; however, the responses of vasopressin and oxytocin were significantly greater, and those of renin and norepinephrine were markedly potentiated in the ADRX group. Heart rate recovered faster in the ADRX group and was elevated, compared to the sham value, for most of the 5-h period. Restitution of blood volume was attenuated in the ADRX group, although the restitution of plasma protein was not different between the groups. A significant difference in the change in plasma osmolality between groups after hemorrhage may account for the attenuated restitution of blood volume. After an overnight fast, which reduced blood volume in both groups of rats, the plasma renin concentration rose still further in ADRX rats; the differences in other measured variables observed between fed ADRX and sham groups remained the same. The insulin-induced 50% decrease in glucose caused minor effects on arterial blood pressure and heart rate and occasioned responses in renin and norepinephrine of similar magnitudes in the two groups. We conclude that in the absence of the adrenals, rats restore arterial pressure after hemorrhage remarkably well through potentiation of the responses of other vasoactive neural and hormonal systems. In these studies the marked potentiation of the renin response suggests that the renin-angiotensin system may be important in the maintenance of arterial blood pressure after reductions in blood volume.
Problem of intraoperative anatomical shift in image-guided surgery
NASA Astrophysics Data System (ADS)
Nauta, Haring J.; Bonnen, J. G.
1998-06-01
Experience with image guided, frameless stereotactic neurosurgery shows that intraoperative brain position shifts can be large enough to be problematic, and can occur in different directions at different directions at different stages of an operation. An understanding of the behavior of shifts will allow the surgeon to make the most appropriate use of the image guidance by first minimizing the shift itself, and then anticipating and compensating for any influence the remaining shift will have on the accuracy of the guidance. Three types of shift are described. Type I shift is a local outward bulging that occurs after the skull and dura are opened but before a mass lesion is resected. Type II shift is a local collapse of the brain tissue into the space previously occupied by the tumor. Type III shift is related to loss of cerebrospinal fluid or brain dehydration and is a generalized, more symmetric loss of brain volume. Strategies to minimize these types of shift include appropriate use of medical measures to reduce brain swelling early in the procedure without producing so much brain dehydration that Type II shift is accentuated later in the procedure. Other strategies include mechanical stabilization of brain position with retractors. Anticipating shift, the neurosurgeon should use the guidance as far as possible to map key boundaries early in the procedure before shift becomes more pronounced. Ultimately, however, the correction for the problem of intraoperative brain shift will require the ability to update the imaging data during the surgery.
Hematoma formation during breast core needle biopsy in women taking antithrombotic therapy.
Chetlen, Alison L; Kasales, Claudia; Mack, Julie; Schetter, Susann; Zhu, Junjia
2013-07-01
The purpose of this study was to compare hematoma formation after breast core needle biopsy performed on patients undergoing and those not undergoing concurrent antithrombotic therapy. A prospective assessment of core needle biopsies (stereotactic, ultrasound guided, or MRI guided) performed on patients enrolled between September 2011 and July 2012 formed the basis of this study. Postprocedure mediolateral and craniocaudal mammograms were evaluated for the presence and size of hematomas. Patients were clinically evaluated for complications 24-48 hours after the procedure through telephone call or face-to-face consultation. Needle size, type of biopsy, and presence of hematoma and documented complications were correlated with use of antithrombotic agents (including aspirin, warfarin, clopidogrel, and daily nonsteroidal antiinflammatory medications). No clinically significant hematomas or bleeding complications were found. Eighty-nine of 617 (14.4%) non-clinically significant hematomas were detected on postprocedure mammograms. The probability of development of a non-clinically significant hematoma was 21.6% for patients taking antithrombotics and 13.0% for those not taking antithrombotics. Concurrent antithrombotic therapy and larger needle gauge were significant factors contributing to the probability of hematoma formation. The volume of the hematoma was not related to needle gauge or presence of antithrombotic therapy. No clinically significant hematomas were found. Because there are potential life-threatening risks to stopping antithrombotic therapy before breast biopsy, withholding antithrombotic therapy for core needle breast biopsy is not recommended because the incidence of non-clinically significant hematoma is low.
Booth, Jeremy T; Caillet, Vincent; Hardcastle, Nicholas; O'Brien, Ricky; Szymura, Kathryn; Crasta, Charlene; Harris, Benjamin; Haddad, Carol; Eade, Thomas; Keall, Paul J
2016-10-01
Real time adaptive radiotherapy that enables smaller irradiated volumes may reduce pulmonary toxicity. We report on the first patient treatment of electromagnetic-guided real time adaptive radiotherapy delivered with MLC tracking for lung stereotactic ablative body radiotherapy. A clinical trial was developed to investigate the safety and feasibility of MLC tracking in lung. The first patient was an 80-year old man with a single left lower lobe lung metastasis to be treated with SABR to 48Gy in 4 fractions. In-house software was integrated with a standard linear accelerator to adapt the treatment beam shape and position based on electromagnetic transponders implanted in the lung. MLC tracking plans were compared against standard ITV-based treatment planning. MLC tracking plan delivery was reconstructed in the patient to confirm safe delivery. Real time adaptive radiotherapy delivered with MLC tracking compared to standard ITV-based planning reduced the PTV by 41% (18.7-11cm 3 ) and the mean lung dose by 30% (202-140cGy), V20 by 35% (2.6-1.5%) and V5 by 9% (8.9-8%). An emerging technology, MLC tracking, has been translated into the clinic and used to treat lung SABR patients for the first time. This milestone represents an important first step for clinical real-time adaptive radiotherapy that could reduce pulmonary toxicity in lung radiotherapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L
2016-02-06
Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.
Jensen, Dennis M.; Ohning, Gordon V.; Kovacs, Thomas O.G.; Jutabha, Rome; Ghassemi, Kevin; Dulai, Gareth S.; Machicado, Gustavo A.
2015-01-01
BACKGROUND AND AIMS Few prospective reports describe the short term natural history of colon diverticular hemorrhage based upon stigmata of recent hemorrhage and none include blood flow detection for risk stratification or as a guide to definitive hemostasis. Our purposes are to report the 30 day natural history of definitive diverticular hemorrhage based upon stigmata and to describe Doppler probe blood flow detection and as a guide to definitive hemostasis. METHODS Different cohorts of patients with severe diverticular bleeding and stigmata on urgent colonoscopy are reported. For 30 day natural history, patients were treated medically. If severe rebleeding occurred, they had surgical or angiographic treatment. Natural history with major stigmata (active bleeding, visible vessel, or adherent clot) and no stigmata or flat spots after washing away clots are reported. Doppler probe detection of arterial blood flow underneath stigmata before and after hemostasis is also reported in a recent cohort. RESULTS For natural history patients with major stigmata treated medically had 65.8% (25/38) rebleeding rates and 44.7% (17/38) had intervention for hemostasis. Patients with spots or clean bases had no rebleeding. Doppler probe detected arterial blood flow in 92% of major stigmata, none after hemostasis and no one rebled. CONCLUSIONS 1. Patients with major stigmata treated medically had high rates of rebleeding and intervention for hemostasis. 2. Patients with clean diverticula or only flat spots had no rebleeding. 3. High rates of arterial blood flow were detected under major stigmata with Doppler probe but with obliteration by hemostasis no rebleeding occurred. PMID:26227931
A current perspective on stereotactic body radiation therapy for pancreatic cancer
Hong, Julian C; Czito, Brian G; Willett, Christopher G; Palta, Manisha
2016-01-01
Pancreatic cancer is a formidable malignancy with poor outcomes. The majority of patients are unable to undergo resection, which remains the only potentially curative treatment option. The management of locally advanced (unresectable) pancreatic cancer is controversial; however, treatment with either chemotherapy or chemoradiation is associated with high rates of local tumor progression and metastases development, resulting in low survival rates. An emerging local modality is stereotactic body radiation therapy (SBRT), which uses image-guided, conformal, high-dose radiation. SBRT has demonstrated promising local control rates and resultant quality of life with acceptable rates of toxicity. Over the past decade, increasing clinical experience and data have supported SBRT as a local treatment modality. Nevertheless, additional research is required to further evaluate the role of SBRT and improve upon the persistently poor outcomes associated with pancreatic cancer. This review discusses the existing clinical experience and technical implementation of SBRT for pancreatic cancer and highlights the directions for ongoing and future studies. PMID:27826200
A current perspective on stereotactic body radiation therapy for pancreatic cancer.
Hong, Julian C; Czito, Brian G; Willett, Christopher G; Palta, Manisha
2016-01-01
Pancreatic cancer is a formidable malignancy with poor outcomes. The majority of patients are unable to undergo resection, which remains the only potentially curative treatment option. The management of locally advanced (unresectable) pancreatic cancer is controversial; however, treatment with either chemotherapy or chemoradiation is associated with high rates of local tumor progression and metastases development, resulting in low survival rates. An emerging local modality is stereotactic body radiation therapy (SBRT), which uses image-guided, conformal, high-dose radiation. SBRT has demonstrated promising local control rates and resultant quality of life with acceptable rates of toxicity. Over the past decade, increasing clinical experience and data have supported SBRT as a local treatment modality. Nevertheless, additional research is required to further evaluate the role of SBRT and improve upon the persistently poor outcomes associated with pancreatic cancer. This review discusses the existing clinical experience and technical implementation of SBRT for pancreatic cancer and highlights the directions for ongoing and future studies.
Matsuoka, Tadashi; Suzuki, Masaru; Sano, Motoaki; Hayashida, Kei; Tamura, Tomoyoshi; Homma, Koichiro; Fukuda, Keiichi; Sasaki, Junichi
2017-09-01
Mortality of hemorrhagic shock primarily depends on whether or not the patients can endure the loss of circulating volume until radical treatment is applied. We investigated whether hydrogen (H2) gas inhalation would influence the tolerance to hemorrhagic shock and improve survival. Hemorrhagic shock was achieved by withdrawing blood until the mean arterial blood pressure reached 30-35 mm Hg. After 60 minutes of shock, the rats were resuscitated with a volume of normal saline equal to four times the volume of shed blood. The rats were assigned to either the H2 gas (1.3% H2, 26% O2, 72.7% N2)-treated group or the control gas (26% O2, 74% N2)-treated group. Inhalation of the specified gas mixture began at the initiation of blood withdrawal and continued for 2 hours after fluid resuscitation. The survival rate at 6 hours after fluid resuscitation was 80% in H2 gas-treated rats and 30% in control gas-treated rats (p < 0.05). The volume of blood that was removed through a catheter to induce shock was significantly larger in the H2 gas-treated rats than in the control rats. Despite losing more blood, the increase in serum potassium levels was suppressed in the H2 gas-treated rats after 60 minutes of shock. Fluid resuscitation completely restored blood pressure in the H2 gas-treated rats, whereas it failed to fully restore the blood pressure in the control gas-treated rats. At 2 hours after fluid resuscitation, blood pressure remained in the normal range and metabolic acidosis was well compensated in the H2 gas-treated rats, whereas we observed decreased blood pressure and uncompensated metabolic acidosis and hyperkalemia in the surviving control gas-treated rats. H2 gas inhalation delays the progression to irreversible shock. Clinically, H2 gas inhalation is expected to stabilize the subject until curative treatment can be performed, thereby increasing the probability of survival after hemorrhagic shock.
Liu, Feng-Di; Zhao, Rong; Feng, Xiao-Yan; Shi, Yan-Hui; Wu, Yi-Lan; Shen, Xiao-Lei; Li, Ge-Fei; Liu, Yi-Sheng; Zhao, Ying; He, Xin-Wei; Yin, Jia-Wen; Zhuang, Mei-Ting; Zhao, Bing-Qiao; Liu, Jian-Ren
2018-05-09
Managing endovascular thrombectomy (ET) in diabetic ischemic stroke (IS) with novel anticoagulants is challenging due to putative risk of intracerebral hemorrhage. The study evaluates increased hemorrhagic transformation (HT) risk in Rivaroxaban-treated diabetic rats post ET. Diabetes was induced in male Sprague-Dawley rats by intraperitoneal injection of 60 mg/kg streptozotocin. After 4-weeks, rats were pretreated orally with 30 mg/kg Rivaroxaban/saline; prothrombin time was monitored. IS and ET was induced after 1 h, by thread-induced transient middle cerebral artery occlusion (tMCAO) that mimicked mechanical ET for proximal MCA occlusion at 60 min. After 24 h reperfusion, infarct volumes, HT, blood-brain barrier (BBB) permeability, tight junction at peri-ischemic lesion and matrix metalloproteinase-9 (MMP-9) activity was measured. Diabetic rats seemed to exhibit increased infarct volume and HT at 24 h after ET than normal rats. Infarct volumes and functional outcomes did not differ between Rivaroxaban and diabetic control groups. A significant increase in HT volumes and BBB permeability under Rivaroxaban treatment was not detected. Compared to diabetic control group, neither the occludin expression was remarkably lower in the Rivaroxaban group nor the MMP-9 activity was higher. Together, Rivaroxaban does not increase HT after ET in diabetic rats with proximal MCA occlusion, since Rivaroxaban has fewer effects on post-ischemic BBB permeability.
A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.
Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M
To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18 F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Image guided surgery in the management of craniocerebral gunshot injuries
Elserry, Tarek; Anwer, Hesham; Esene, Ignatius Ngene
2013-01-01
Background: A craniocerebral trauma caused by firearms is a complex injury with high morbidity and mortality. One of the most intriguing and controversial part in their management in salvageable patients is the decision to remove the bullet/pellet. A bullet is foreign to the brain and, in principle, should be removed. Surgical options for bullet extraction span from conventional craniotomy, through C-arm-guided surgery to minimally invasive frame or frameless stereotaxy. But what is the best surgical option? Methods: We prospectively followed up a cohort of 28 patients with cranio-cerebral gunshot injury (CCHSI) managed from January to December 2012 in our department of neurosurgery. The missiles were extracted via stereotaxy (frame or frameless), C-arm-guided, or free-hand-based surgery. Cases managed conservatively were excluded. The Glasgow Outcome Score was used to assess the functional outcome on discharge. Results: Five of the eight “stereotactic cases” had an excellent outcome after missile extraction while the initially planned stereotaxy missed locating the missile in three cases and were thus subjected to free hand craniotomy. Excellent outcome was obtained in five of the nine “neuronavigation cases, five of the eight cases for free hand surgery based on the bony landmarks, and five of the six C-arm-based surgery. Conclusion: Conventional craniotomy isn’t indicated in the extraction of isolated, retained, intracranial firearm missiles in civilian injury but could be useful when the missile is incorporated within a surgical lesion. Stereotactic surgery could be useful for bullet extraction, though with limited precision in identifying small pellets because of their small sizes, thus exposing patients to same risk of brain insult when retrieving a missile by conventional surgery. Because of its availability, C-arm-guided surgery continues to be of much benefit, especially in emergency situations. We recommend an extensive long-term study of these treatment modalities for CCGSI. PMID:24349869
The value of image coregistration during stereotactic radiosurgery.
Koga, T; Maruyama, K; Igaki, H; Tago, M; Saito, N
2009-05-01
Coregistration of any neuroimaging studies into treatment planning for stereotactic radiosurgery became easily applicable using the Leksell Gamma Knife 4C, a new model of gamma knife. The authors investigated the advantage of this image processing. Since installation of the Leksell Gamma Knife 4C at the authors' institute, 180 sessions of radiosurgery were performed. Before completion of planning, coregistration of frameless images of other modalities or previous images was considered to refine planning. Treatment parameters were compared for planning before and after refinement by use of coregistered images. Coregistered computed tomography clarified the anatomical structures indistinct on magnetic resonance imaging. Positron emission tomography visualized lesions disclosing metabolically high activity. Coregistration of prior imaging distinguished progressing lesions from stable ones. Diffusion-tensor tractography was integrated for lesions adjacent to the corticospinal tract or the optic radiation. After refinement of planning in 36 sessions, excess treated volume decreased (p = 0.0062) and Paddick conformity index improved (p < 0.001). Maximal dose to the white matter tracts was decreased (p < 0.001). Image coregistration provided direct information on anatomy, metabolic activity, chronological changes, and adjacent critical structures. This gathered information was sufficiently informative during treatment planning to supplement ambiguous information on stereotactic images, and was useful especially in reducing irradiation to surrounding normal structures.
Peiffert, D; Baumann, A-S; Marchesi, V
2014-04-01
Cyberknife(®) is a dedicated stereotactic radiotherapy device. This new technology permits precise delivery of high dose gradient radiation therapy while sparing the surrounding organs at risk. Hepatic metastases of colorectal cancer (HMCRC) are an example of a lesion where treatment with Cyberknife(®) is indicated because they are located in a radio-sensitive organ and curative treatment is based on focal eradication (resection, radiofrequency ablation,...). The local control rate at one year is reported to be 70 to 100% depending on the study. Tolerance is excellent with less than a 5% rate of acute grade 3 or 4 side effects (nausea, vomiting, gastro-duodenal ulcer). The specific hepatotoxicity of radiotherapy, so-called radiation-induced liver disease (RILD), was found in only one study. Candidates for stereotactic radiotherapy are patients in whom disease is controlled except for intrahepatic disease with 1-3 hepatic metastases ≤ 6 cm in size who have contraindications for surgery, a WHO stage ≤ 2, a volume of healthy liver ≥ 700 cm(3) and normal liver function. It is actually a very simple treatment that results in very good local control with few contraindications. Its place in the management strategy of liver metastases needs further clarification. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Shock in the Nonhuman Primate. Volume 2. Abstracts of the Published Literature, 1974-1977
1977-06-01
primates from hemorrhagic and septic shock. Trunkey, D., J. Holcroft, and M. A. Carpenter ... ........... .... 42 Calcium flux during hemorrhagic...virtually absent. In vitro endotoxin-leukocyte interaction reproduced all changes seen in sequestered PMN-leukocytes with the exception of leukocyte...Although there is no pre- sently known clinical state referable to lead-endotoxin interaction and since our experimental conditions were not
McCowan, Peter M; Asuni, Ganiyu; Van Uytven, Eric; VanBeek, Timothy; McCurdy, Boyd M C; Loewen, Shaun K; Ahmed, Naseer; Bashir, Bashir; Butler, James B; Chowdhury, Amitava; Dubey, Arbind; Leylek, Ahmet; Nashed, Maged
2017-04-01
To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. From December 2013 to July 2016, 117 stereotactic body radiation therapy-volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in June 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB-predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCowan, Peter M., E-mail: pmccowan@cancercare.mb.ca; Asuni, Ganiyu; Van Uytven, Eric
Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. Methods and Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy–volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in Junemore » 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB–predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. Results: The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Conclusions: Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors.« less
P13.11USAGE OF CYBER KNIFE HYPOFRACTIONATED RADIOSURGERY IN HIGH GRADE GLIOMAS COMPLEX TREATMENT
Glavatskyi, O.; Buryk, V.M.; Kardash, K.A.; Pylypas, O.P.; Chebotaryova, T.I.
2014-01-01
INTRODUCTION: A complex approach to the treatment of malignant brain tumors includes maximum surgical resection, radiotherapy and chemotherapy. The purpose of the current study is to review retrospectively the ability of Cyber Knife (“Accuray Incorporated”, Sunnyvale, CA, USA) radiosurgery to provide local tumor control of newly diagnosed or recurrent malignant brain tumors. MATERIAL AND METHOD: 26 patients with malignant brain tumors (glioblastoma multiform (GBM) - 14 patients, anaplastic astrocytoma (AA) - 12 patients) were treated in 2012-2013 with Cyber Knife stereotactic radiosurgery. Before radiosurgery 8 patients had complete removal of the tumor, 9 patients had subtotal resection and 9 patients had biopsy. 17 patients received adjuvant chemotherapy with temozolomide according to the different treatment protocols. 9 patients who were previously irradiated received re-irradiation. In all patients CT, MRI, PET (native, enhanced, CT-perfusion, MRI-diffusion (DWI) studies) before and after treatment were performed with (3, 6, 12, 18 month follow up). The volume of tumors ranged from 10-12 cm3 to 101,1 cm3. The maximum mean dose of irradiation applied was 36.99 Gy (ranged from 21,3 Gy to 48,8 Gy). 3-6 fractions of hypofractionated treatment were used. RESULTS: At this stage of the study, we assessed the absence of complications after stereotactic hypofractionated radiosurgery. Objective survival evaluation has being performed in 12-24 months after radiosurgical treatment. A significant decrease in the number and severity of seizures was seen in 7 patients out of 21 (33 %). 18 patients (64%) had regression of limb weakness. In case of biopsy 7 of 9 tumors (78 %) showed a decrease in volume. In patients with clinical deterioration (3 patients) repeated surgical treatment was performed. All of them had signs of post-irradiation necrosis and pathomorphosis in tumor tissue. Median overall survival and progression free survival were 17 months and 11 months respectively. CONCLUSIONS: Hypofractionated stereotactic radiosurgery is one of possible treatment options for high-grade gliomas which leads to a decrease in tumor volume and improves clinical status of patients even in cases of re-irradiation. Surgical treatment after radiosurgery doesn't worsen median overall survival and progression free survival prognosis.
Atlas-based system for functional neurosurgery
NASA Astrophysics Data System (ADS)
Nowinski, Wieslaw L.; Yeo, Tseng T.; Yang, Guo L.; Dow, Douglas E.
1997-05-01
This paper addresses the development of an atlas-based system for preoperative functional neurosurgery planning and training, intraoperative support and postoperative analysis. The system is based on Atlas of Stereotaxy of the Human Brain by Schaltenbrand and Wahren used for interactive segmentation and labeling of clinical data in 2D/3D, and for assisting stereotactic targeting. The atlas microseries are digitized, enhanced, segmented, labeled, aligned and organized into mutually preregistered atlas volumes 3D models of the structures are also constructed. The atlas may be interactively registered with the actual patient's data. Several other features are also provided including data reformatting, visualization, navigation, mensuration, and stereotactic path display and editing in 2D/3D. The system increases the accuracy of target definition, reduces the time of planning and time of the procedure itself. It also constitutes a research platform for the construction of more advanced neurosurgery supporting tools and brain atlases.
Feasibility evaluation of a motion detection system with face images for stereotactic radiosurgery.
Yamakawa, Takuya; Ogawa, Koichi; Iyatomi, Hitoshi; Kunieda, Etsuo
2011-01-01
In stereotactic radiosurgery we can irradiate a targeted volume precisely with a narrow high-energy x-ray beam, and thus the motion of a targeted area may cause side effects to normal organs. This paper describes our motion detection system with three USB cameras. To reduce the effect of change in illuminance in a tracking area we used an infrared light and USB cameras that were sensitive to the infrared light. The motion detection of a patient was performed by tracking his/her ears and nose with three USB cameras, where pattern matching between a predefined template image for each view and acquired images was done by an exhaustive search method with a general-purpose computing on a graphics processing unit (GPGPU). The results of the experiments showed that the measurement accuracy of our system was less than 0.7 mm, amounting to less than half of that of our previous system.
NASA Astrophysics Data System (ADS)
Yeo, U. J.; Taylor, M. L.; Kron, T.; Pham, D.; Siva, S.; Franich, R. D.
2013-06-01
Respiratory motion induces dosimetric uncertainties for thoracic and abdominal cancer radiotherapy (RT) due to deforming and moving anatomy. This study investigates the extent of dosimetric differences between conventional 3D treatment planning and path-integrated 4D treatment planning in liver stereotactic body radiotherapy (SBRT). Respiratory-correlated 4DCT image sets with 10 phases were acquired for patients with liver tumours. Path-integrated 4D dose accumulation was performed using dose-warping techniques based on deformable image registration. Dose-volume histogram analysis demonstrated that the 3D planning approach overestimated doses to targets by up to 24% and underestimated dose to normal liver by ~4.5%, compared to the 4D planning methodology. Therefore, 4D planning has the potential to quantify such issues of under- and/or over-dosage and improve treatment accuracy.
Kishan, Amar U; Cao, Minsong; Wang, Pin-Chieh; Mikaeilian, Argin G; Tenn, Stephen; Rwigema, Jean-Claude M; Sheng, Ke; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Lee, Percy
2015-01-01
The purpose of this study was to investigate the dosimetric feasibility of liver stereotactic body radiation therapy (SBRT) using a teletherapy system equipped with 3 rotating (60)Co sources (tri-(60)Co system) and a built-in magnetic resonance imager (MRI). We hypothesized tumor size and location would be predictive of favorable dosimetry with tri-(60)Co SBRT. The primary study population consisted of 11 patients treated with SBRT for malignant hepatic lesions whose linear accelerator (LINAC)-based SBRT plans met all mandatory Radiation Therapy Oncology Group (RTOG) 1112 organ-at-risk (OAR) constraints. The secondary study population included 5 additional patients whose plans did not meet the mandatory constraints. Patients received 36 to 60 Gy in 3 to 5 fractions. Tri-(60)Co system SBRT plans were planned with ViewRay system software. All patients in the primary study population had tri-(60)Co SBRT plans that passed all RTOG constraints, with similar planning target volume coverage and OAR doses to LINAC plans. Mean liver doses and V10Gy to the liver, although easily meeting RTOG 1112 guidelines, were significantly higher with tri-(60)Co plans. When the 5 additional patients were included in a univariate analysis, the tri-(60)Co SBRT plans were still equally able to pass RTOG constraints, although they did have inferior ability to pass more stringent liver and kidney constraints (P < .05). A multivariate analysis found the ability of a tri-(60)Co SBRT plan to meet these constraints depended on lesion location and size. Patients with smaller or more peripheral lesions (as defined by distance from the aorta, chest wall, liver dome, and relative lesion volume) were significantly more likely to have tri-(60)Co plans that spared the liver and kidney as well as LINAC plans did (P < .05). It is dosimetrically feasible to perform liver SBRT with a tri-(60)Co system with a built-in MRI. Patients with smaller or more peripheral lesions are more likely to have optimal liver and kidney sparing, with the added benefit of MRI guidance, when receiving tri-(60)Co-based SBRT. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dixon, Shaheen, E-mail: shaheen7noorani@gmail.com; Chan, Victoria, E-mail: dr.victoriac@gmail.com; Shrivastava, Vivek, E-mail: vivshriv@yahoo.com
2013-08-01
PurposeTo assess the relative efficacy of empiric gastroduodenal artery (GDA) embolization in reducing recurrent hemorrhage compared to image-guided targeted embolization.MethodsData were retrospectively collected for consecutive patients who had catheter angiography for major upper gastrointestinal hemorrhage from May 2008 to November 2010 (n = 40). The total number of cases were divided into two main groups according to angiographic findings: those that demonstrated a site of hemorrhage on catheter angiography (group 1, n = 13), and those where the site of hemorrhage was not identified on catheter angiography (group 2, n = 27). Group 2 was then further divided into patientsmore » who received empiric embolization (group 2a, n = 20) and those who had no embolization performed after angiography (group 2b, n = 7).ResultsThe technical and clinical success rates for embolization in groups 1 and 2a were, respectively, 100 vs. 95 %, and 85 vs. 80 %. There was no statistical significance in the recurrent hemorrhage rate, reintervention rate, or 30 day mortality between targeted and empiric embolization groups. There were no complications attributed to embolization within this study cohort.ConclusionCases of duodenal-related major upper gastrointestinal hemorrhage where no embolization is performed have poor outcome. Empiric embolization of the GDA in patients with major upper gastrointestinal hemorrhage refractory to endoscopic treatment appears to be a safe and effective treatment, with low reintervention rates and good clinical outcome comparable to patients where the site of hemorrhage is localized and embolized with computed tomographic angiography or catheter angiography and embolized.« less
Muders, Thomas; Theuerkauf, Nils; Spitzhüttl, Juliane; Schellhaas, Torsten; Schewe, Jens-Christian; Guenther, Ulf; Wrigge, Hermann; Putensen, Christian
2017-01-01
Background Despite being still invasive and challenging, technical improvement has resulted in broader and more frequent application of extracorporeal membrane oxygenation (ECMO), to prevent hypoxemia and to reduce invasiveness of mechanical ventilation (MV). Heparin-coated ECMO-circuits are currently standard of care, in addition to heparin based anticoagulation (AC) regimen guided by activated clotting time (ACT) or activated partial thromboplastin time (aPTT). Despite these advances, a reliable prediction of hemorrhage is difficult and the risk of hemorrhagic complication remains unfortunately high. We hypothesized, that there are coagulation parameters that are indices for a higher risk of hemorrhage under veno-venous (VV)-ECMO therapy. Methods Data from 36 patients with severe respiratory failure treated with VV-ECMO at a University Hospital intensive care unit (ICU) were analyzed retrospectively. Patients were separated into two groups based on severity of hemorrhagic complications and transfusion requirements. The following data were collected: demographics, hemodynamic data, coagulation samples, transfusion requirements, change of ECMO-circuit during treatment and adverse effects, including hemorrhage and thrombosis. Results In this study 74 hemorrhagic events were observed, one third of which were severe. Patients suffering from severe hemorrhage had a lower survival rate on VV-ECMO (43% vs. 91%; P=0.002) and in ICU (36% vs. 86%; P=0.002). SAPS II, factor VII and X were different between mild and severe hemorrhage group. Conclusions Severe hemorrhage under VV-ECMO is associated with higher mortality. Only factor VII and X differed between groups. Further clinical studies are required to determine the timing of initiation and targets for AC therapies during VV-ECMO. PMID:29312706
SU-E-J-187: Management of Optic Organ Motion in Fractionated Stereotactic Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manning, M; Maurer, J
2015-06-15
Purpose: Fractionated stereotactic radiotherapy (FSRT) for optic nerve tumors can potentially use planning target volume (PTV) expansions as small as 1–5 mm. However, the motion of the intraorbital segment of the optic nerve has not been studied. Methods: A subject with a right optic nerve sheath meningioma underwent CT simulation in three fixed gaze positions: right, left, and fixed forward at a marker. The gross tumor volume (GTV) and the organs-at-risk (OAR) were contoured on all three scans. An IMRT plan using 10 static non-coplanar fields to 50.4 Gy in 28 fractions was designed to treat the fixed-forward gazing GTVmore » with a 1 mm PTV, then resulting coverage was evaluated for the GTV in the three positions. As an alternative, the composite structures were computed to generate the internal target volume (ITV), 1 mm expansion free-gazing PTV, and planning organat-risk volumes (PRVs) for free-gazing treatment. A comparable IMRT plan was created for the free-gazing PTV. Results: If the patient were treated using the fixed forward gaze plan looking straight, right, and left, the V100% for the GTV was 100.0%, 33.1%, and 0.1%, respectively. The volumes of the PTVs for fixed gaze and free-gazing plans were 0.79 and 2.21 cc, respectively, increasing the PTV by a factor of 2.6. The V100% for the fixed gaze and free-gazing plans were 0.85 cc and 2.8 cc, respectively increasing the treated volume by a factor of 3.3. Conclusion: Fixed gaze treatment appears to provide greater organ sparing than free-gazing. However unanticipated intrafraction right or left gaze can produce a geometric miss. Further study of optic nerve motion appears to be warranted in areas such as intrafraction optical confirmation of fixed gaze and optimized gaze directions to minimize lens and other normal organ dose in cranial radiotherapy.« less
Association of Subdural Hematoma With Increased Mortality in Lobar Intracerebral Hemorrhage
Patel, Pratik V.; FitzMaurice, Emilie; Kaveer Nandigam, R. N.; Auluck, Pavan; Viswanathan, Anand; Goldstein, Joshua N.; Rosand, Jonathan; Greenberg, Steven M.; Smith, Eric E.
2011-01-01
Objective To determine the prevalence of subdural hematoma (SDH) in patients presenting with primary non-traumatic lobar intracerebral hemorrhage (ICH) and characteristics associated with the presence of SDH. Design Retrospective analysis of data collected in a prospective cohort study. Setting Hospital. Patients Consecutive sample of 200 patients with primary lobar ICH and 75 patients with deep hemispheric ICH. Main Outcome Measures Presence of SDH and mortality. Results Subdural hematoma was present in 40 of 200 patients (20%) with primary lobar ICH. By contrast, SDH was not present in any of 75 consecutive patients with deep hemispheric ICH (P<.001 for comparison with lobar ICH). Intracerebral hemorrhage volume higher than 60 cm3 was the only independent predictor of SDH (odds ratio [OR], 2.69; 95% confidence interval [CI], 1.14–6.34; P=.02). Subdural hematoma thickness more than 5 mm was an independent predictor of increased 30-day mortality (OR, 7.60; 95% CI, 1.86–30.99; P=.005) after controlling for other factors including ICH volume. Further analysis showed that the effect of SDH on mortality depended on ICH volume, with larger odds for mortality in those with low ICH volume (OR, 12.85; 95% CI, 2.42–68.23; P=.003 for those with ICH volume <30 cm3). Cerebral amyloid angiopathy was present in 8 of 9 patients with pathological specimens. Conclusions Nontraumatic SDH frequently accompanies primary lobar ICH and is associated with higher 30-day mortality, particularly when the ICH volume is relatively low. Rupture of an amyloid-laden leptomeningeal vessel, with extravasation into the brain parenchyma and subdural space, may be the pathogenic mechanism. PMID:19139303
Takaku, Mariana; da Silva, Andre Carnevali; Iritsu, Nathalie Izumi; Vianna, Pedro Thadeu Galvao; Castiglia, Yara Marcondes Machado
2018-01-01
Parecoxib, a selective COX-2 inhibitor, is used to improve analgesia in postoperative procedures. Here we evaluated whether pretreatment with a single dose of parecoxib affects the function, cell injury, and inflammatory response of the kidney of rats subjected to acute hemorrhage. Inflammatory response was determined according to serum and renal tissue cytokine levels (IL-1 α , IL-1 β , IL-6, IL-10, and TNF- α ). Forty-four adult Wistar rats anesthetized with sevoflurane were randomized into four groups: placebo/no hemorrhage (Plc/NH); parecoxib/no hemorrhage (Pcx/NH); placebo/hemorrhage (Plc/H); and parecoxib/hemorrhage (Pcx/H). Pcx groups received a single dose of intravenous parecoxib while Plc groups received a single dose of placebo (isotonic saline). Animals in hemorrhage groups underwent bleeding of 30% of blood volume. Renal function and renal histology were then evaluated. Plc/H showed the highest serum levels of cytokines, suggesting that pretreatment with parecoxib reduced the inflammatory response in rats subjected to hemorrhage. No difference in tissue cytokine levels between groups was observed. Plc/H showed higher percentage of tubular dilation and degeneration, indicating that parecoxib inhibited tubular injury resulting from renal hypoperfusion. Our findings indicate that pretreatment with a single dose of parecoxib reduced the inflammatory response and tubular renal injury without altering renal function in rats undergoing acute hemorrhage.
Severe postpartum hemorrhage from uterine atony: a multicentric study.
Montufar-Rueda, Carlos; Rodriguez, Laritza; Jarquin, José Douglas; Barboza, Alejandra; Bustillo, Maura Carolina; Marin, Flor; Ortiz, Guillermo; Estrada, Francisco
2013-01-01
Postpartum hemorrhage (PPH) is an important cause of maternal mortality (MM) around the world. Seventy percent of the PPH corresponds to uterine atony. The objective of our study was to evaluate multicenter PPH cases during a 10-month period, and evaluate severe postpartum hemorrhage management. The study population is a cohort of vaginal delivery and cesarean section patients with severe postpartum hemorrhage secondary to uterine atony. The study was designed as a descriptive, prospective, longitudinal, and multicenter study, during 10 months in 13 teaching hospitals. Total live births during the study period were 124,019 with 218 patients (0.17%) with severe postpartum hemorrhage (SPHH). Total maternal deaths were 8, for mortality rate of 3.6% and a MM rate of 6.45/100,000 live births (LB). Maternal deaths were associated with inadequate transfusion therapy. In all patients with severe hemorrhage and subsequent hypovolemic shock, the most important therapy is intravascular volume resuscitation, to reduce the possibility of target organ damage and death. Similarly, the current proposals of transfusion therapy in severe or massive hemorrhage point to early transfusion of blood products and use of fresh frozen plasma, in addition to packed red blood cells, to prevent maternal deaths.
Efficacy and Safety of Ethanol Ablation for Branchial Cleft Cysts.
Ha, E J; Baek, S M; Baek, J H; Shin, S Y; Han, M; Kim, C-H
2017-12-01
Branchial cleft cyst is a common congenital lesion of the neck. This study evaluated the efficacy and safety of ethanol ablation as an alternative treatment to surgery for branchial cleft cyst. Between September 2006 and October 2016, ethanol ablation was performed in 22 patients who refused an operation for a second branchial cleft cyst. After the exclusion of 2 patients who were lost to follow-up, the data of 20 patients were retrospectively evaluated. All index masses were confirmed as benign before treatment. Sonography-guided aspiration of the cystic fluid was followed by injection of absolute ethanol (99%) into the lesion. The injected volume of ethanol was 50%-80% of the volume of fluid aspirated. Therapeutic outcome, including the volume reduction ratio, therapeutic success rate (volume reduction ratio of >50% and/or no palpable mass), and complications, was evaluated. The mean index volume of the cysts was 26.4 ± 15.7 mL (range, 3.8-49.9 mL). After ablation, the mean volume of the cysts decreased to 1.2 ± 1.1 mL (range, 0.0-3.5 mL). The mean volume reduction ratio at last follow-up was 93.9% ± 7.9% (range, 75.5%-100.0%; P < .001). Therapeutic success was achieved in all nodules (20/20, 100%), and the symptomatic ( P < .001) and cosmetic ( P < .001) scores had improved significantly by the last follow-up. In 1 patient, intracystic hemorrhage developed during the aspiration; however, no major complications occurred in any patient. Ethanol ablation is an effective and safe treatment for patients with branchial cleft cysts who refuse, or are ineligible for, an operation. © 2017 by American Journal of Neuroradiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aoyama, Hidefumi; Shirato, Hiroki; Katoh, Norio
Purpose: To investigate the discrepancy between the arteriovenous malformations seen on magnetic resonance angiography (MRA) and on stereotactic digital subtracted angiography (DSA). Methods and Materials: The target volume on stereotactic DSA (V{sub DSA} ) and the target volume on MRA (V{sub MRA} ) were separately delineated in 28 intracranial arteriovenous malformations. The coordinates of the center and the outer edges of V{sub DSA} and V{sub MRA} were calculated and used for the analyses. Results: The standard deviations (mean value) of the displacement of centers of V{sub MRA} from V{sub DSA} were 2.67 mm (-1.82 mm) in the left-right direction, 3.23more » mm (-0.08 mm) in the anterior-posterior direction, and 2.16 mm (0.91 mm) in the craniocaudal direction. V{sub MRA} covered less than 80% of V{sub DSA} in any dimensions in 9 cases (32%), although no significant difference was seen in the target volume between each method, with a mean value of 11.9 cc for V{sub DSA} and 12.3 cc for V{sub MRA} (p = 0.948). Conclusion: The shift of centers between each modality is not negligible. Considering no significant difference between V{sub DSA} and V{sub MRA} , but inadequate coverage of the V{sub DSA} by V{sub MRA} , it is reasonable to consider that the target on MRA might include the feeding artery and draining vein and possibly miss a portion of the nidus.« less
Stereotactic Radiosurgery for Intracranial Ependymomas: An International Multicenter Study.
Kano, Hideyuki; Su, Yan-Hua; Wu, Hsiu-Mei; Simonova, Gabriela; Liscak, Roman; Cohen-Inbar, Or; Sheehan, Jason P; Meola, Antonio; Sharma, Mayur; Barnett, Gene H; Mathieu, David; Vasas, Lucas T; Kaufmann, Anthony M; Jacobs, Rachel C; Lunsford, L Dade
2018-03-28
Stereotactic radiosurgery (SRS) is a potentially important option for intracranial ependymoma patients. To analyze the outcomes of intracranial ependymoma patients who underwent SRS as a part of multimodality management. Seven centers participating in the International Gamma Knife Research Foundation identified 89 intracranial ependymoma patients who underwent SRS (113 tumors). The median patient age was 16.3 yr (2.9-80). All patients underwent previous surgical resection and radiation therapy (RT) of their ependymomas and 40 underwent previous chemotherapy. Grade 2 ependymomas were present in 42 patients (52 tumors) and grade 3 ependymomas in 48 patients (61 tumors). The median tumor volume was 2.2 cc (0.03-36.8) and the median margin dose was 15 Gy (9-24). Forty-seven (53%) patients were alive and 42 (47%) patients died at the last follow-up. The overall survival after SRS was 86% at 1 yr, 50% at 3 yr, and 44% at 5 yr. Smaller total tumor volume was associated with longer overall survival (P = .006). Twenty-two patients (grade 2: n = 9, grade 3: n = 13) developed additional recurrent ependymomas in the craniospinal axis. The progression-free survival after SRS was 71% at 1 yr, 56% at 3 yr, and 48% at 5 yr. Adult age, female sex, and smaller tumor volume indicated significantly better progression-free survival. Symptomatic adverse radiation effects were seen in 7 patients (8%). SRS provides another management option for residual or recurrent progressive intracranial ependymoma patients who have failed initial surgery and RT.
Bae, Sun Hyun; Kim, Mi-Sook; Jang, Won Il; Cho, Chul Koo; Yoo, Hyung Jun; Kim, Kum Bae; Han, Chul Ju; Park, Su Cheol; Lee, Dong Han
2015-08-01
This study evaluated the incidence of hepatic toxicity after stereotactic ablative radiotherapy (SABR) using 3 fractions to the liver, and identified the predictors for hepatic toxicity. We retrospectively reviewed 78 patients with primary and metastatic liver cancers, who underwent SABR using 3 fractions between 2003 and 2011. To examine the incidence of hepatic toxicity, we defined newly developed hepatic toxicity≥grade 2 according to the National Cancer Institute Common Terminology Criteria for Adverse Events v4.0 within 3 months after the end of SABR as a significant adverse event. To identify the predictors for hepatic toxicity, we analyzed several clinical and dosimetric parameters (rV5Gy-rV35Gy: normal liver volume receiving
Neira, Justin A; Ung, Timothy H; Sims, Jennifer S; Malone, Hani R; Chow, Daniel S; Samanamud, Jorge L; Zanazzi, George J; Guo, Xiaotao; Bowden, Stephen G; Zhao, Binsheng; Sheth, Sameer A; McKhann, Guy M; Sisti, Michael B; Canoll, Peter; D'Amico, Randy S; Bruce, Jeffrey N
2017-07-01
OBJECTIVE Extent of resection is an important prognostic factor in patients undergoing surgery for glioblastoma (GBM). Recent evidence suggests that intravenously administered fluorescein sodium associates with tumor tissue, facilitating safe maximal resection of GBM. In this study, the authors evaluate the safety and utility of intraoperative fluorescein guidance for the prediction of histopathological alteration both in the contrast-enhancing (CE) regions, where this relationship has been established, and into the non-CE (NCE), diffusely infiltrated margins. METHODS Thirty-two patients received fluorescein sodium (3 mg/kg) intravenously prior to resection. Fluorescence was intraoperatively visualized using a Zeiss Pentero surgical microscope equipped with a YELLOW 560 filter. Stereotactically localized biopsy specimens were acquired from CE and NCE regions based on preoperative MRI in conjunction with neuronavigation. The fluorescence intensity of these specimens was subjectively classified in real time with subsequent quantitative image analysis, histopathological evaluation of localized biopsy specimens, and radiological volumetric assessment of the extent of resection. RESULTS Bright fluorescence was observed in all GBMs and localized to the CE regions and portions of the NCE margins of the tumors, thus serving as a visual guide during resection. Gross-total resection (GTR) was achieved in 84% of the patients with an average resected volume of 95%, and this rate was higher among patients for whom GTR was the surgical goal (GTR achieved in 93.1% of patients, average resected volume of 99.7%). Intraoperative fluorescein staining correlated with histopathological alteration in both CE and NCE regions, with positive predictive values by subjective fluorescence evaluation greater than 96% in NCE regions. CONCLUSIONS Intraoperative administration of fluorescein provides an easily visualized marker for glioma pathology in both CE and NCE regions of GBM. These findings support the use of fluorescein as a microsurgical adjunct for guiding GBM resection to facilitate safe maximal removal.
Braun, Patrick; Putzer, Gabriel; Strapazzon, Giacomo; Wimmer, Angela; Schnell, Hermann; Arnold, Henrik; Neururer, Sabrina; Brugger, Hermann; Wenzel, Volker; Paal, Peter
2016-07-01
Ventilation of an unprotected airway may result in stomach inflation. The purpose of this study was to evaluate the effect of clinically realistic stomach inflation on cardiopulmonary function during hemorrhagic shock in a porcine model. Pigs were randomized to a sham control group (n = 9), hemorrhagic shock (35 mL kg over 15 min [n = 9]), and hemorrhagic shock combined with stomach inflation (35 mL kg over 15 min and 5 L stomach inflation [n = 10]). When compared with the control group, hemorrhagic shock (n = 9) increased heart rate (103 ± 11 vs. 146 ± 37 beats min; P = 0.002) and lactate (1.4 ± 0.5 vs. 4.0 ± 1.9 mmol L; P < 0.001), and decreased mean arterial blood pressure (81.3 ± 12.8 vs. 35.4 ± 8.1 mmHg; P < 0.001) and stroke-volume index (38.1 ± 6.4 vs. 13.6 ± 4.8 mL min m; P < 0.001). Hemorrhagic shock combined with stomach inflation (n = 10) versus hemorrhagic shock only (n = 9) increased intra-abdominal pressure (27.0 ± 9.3 vs. 1.1 ± 1.0 mmHg; P < 0.001), and decreased stroke-volume index (9.9 ± 6.0 vs. 20.8 ± 8.5 mL min m; P = 0.007), and dynamic respiratory system compliance (10.8 ± 4.5 vs. 38.1 ± 6.1 mL cmH2O; P < 0.001). Before versus after stomach evacuation during hemorrhagic shock, intra-abdominal pressure decreased (27.0 ± 9.3 vs. 9.8 ± 5.4 mmHg; P = 0.042). Survival in the sham control and hemorrhagic shock group was 9 of 9, respectively, and 3 of 10 after hemorrhagic shock and stomach inflation (P < 0.001). During hemorrhagic shock stomach inflation caused an abdominal compartment syndrome and thereby impaired cardiopulmonary function and aerobic metabolism, and increased mortality. Subsequent stomach evacuation partly reversed adverse stomach-inflation triggered effects.
... such as stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) , or proton therapy . Fiducial markers are small ... Proton Therapy Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT) Images related to Fiducial Marker Placement Sponsored ...
Poulsen, Per Rugaard; Worm, Esben Schjødt; Hansen, Rune; Larsen, Lars Peter; Grau, Cai; Høyer, Morten
2015-01-01
Intrafraction motion may compromise the target dose in stereotactic body radiation therapy (SBRT) of tumors in the liver. Respiratory gating can improve the treatment delivery, but gating based on an external surrogate signal may be inaccurate. This is the first paper reporting on respiratory gating based on internal electromagnetic monitoring during liver SBRT. Two patients with solitary liver metastases were treated with respiratory-gated SBRT guided by three implanted electromagnetic transponders. The treatment was delivered in end-exhale with beam-on when the centroid of the three transponders deviated less than 3 mm [left-right (LR) and anterior-posterior (AP) directions] and 4mm [cranio-caudal (CC)] from the planned position. For each treatment fraction, log files were used to determine the transponder motion during beam-on in the actual gated treatments and in simulated treatments without gating. The motion was used to reconstruct the dose to the clinical target volume (CTV) with and without gating. The reduction in D95 (minimum dose to 95% of the CTV) relative to the plan was calculated for both treatment courses. With gating the maximum course mean (standard deviation) geometrical error in any direction was 1.2 mm (1.8 mm). Without gating the course mean error would mainly increase for Patient 1 [to -2.8 mm (1.6 mm) (LR), 7.1 mm (5.8 mm) (CC), -2.6 mm (2.8mm) (AP)] due to a large systematic cranial baseline drift at each fraction. The errors without gating increased only slightly for Patient 2. The reduction in CTV D95 was 0.5% (gating) and 12.1% (non-gating) for Patient 1 and 0.3% (gating) and 1.7% (non-gating) for Patient 2. The mean duty cycle was 55%. Respiratory gating based on internal electromagnetic motion monitoring was performed for two liver SBRT patients. The gating added robustness to the dose delivery and ensured a high CTV dose even in the presence of large intrafraction motion.
ALA-mediated fluorescence-guided resection (FGR) and PDT of glioma
NASA Astrophysics Data System (ADS)
Johansson, Ann; Stepp, Herbert; Beck, Tobias; Beyer, Wolfgang; Pongratz, Thomas; Sroka, Ronald; Meinel, Thomas; Stummer, Walter; Kreth, Friedrich-Wilhelm; Tonn, Jörg-Christian; Baumgartner, Reinhold
2009-06-01
A summary of clinical trials employing photodynamic diagnosis (PDD) and photodynamic therapy (PDT) for the diagnosis and treatment of brain malignancies is presented. Intra-cavity PDT has been performed within the surgical cavity following FGR, employing oral administration of 5-aminolevulinic acid (5-ALA), either targeting fluorescing tissue regions that were not removed during FGR due to safety reasons (referred to as focal PDT, n=20) or illuminating the entire resection cavity (referred to as integral PDT, n=9). Both approaches proved technically feasible and safe. Spectroscopic measurements performed pre-, during and post-PDT revealed Protoporphyrin IX (PpIX)-photobleaching of more than 95% after the delivery of 200 J/cm2. This light dose did not induce any side effects. Furthermore, interstitial PDT (iPDT) has been employed within one feasibility trial (n=10) and one Phase I/II trial (n=15). Here, three to six cylindrical light diffusors (20-30 mm length, 200 mW/cm, 720 J/cm) were positioned within the target tissue under stereotactic guidance. Pre-treatment planning was performed with the intent to target the entire tumour volume with a sufficient light dose while also minimising the risk of any light-induced temperature increase. For the feasibility trial patients with small, recurrent gliomas were included, resulting in a median survival of 15 months as well as some unexpected longterm survivals (up to 5 years). The Phase I/II trial employed the same clinical procedures. Here, the 12-month survival was 35% and the median progression-free survival was 6 months. In summary, stereotactic iPDT in combination with treatment-planning could be shown to be a safe and feasible treatment modality. These trials are presently being extended to also include on-line monitoring of PpIX fluorescence and photobleaching kinetics. Preliminary data has revealed dramatically different PpIX levels and photobleaching kinetics. Such data could possibly be employed for realtime treatment monitoring and as an early prognostic marker for the PDT response.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tai, A; Prior, P; Gore, E
Purpose: 4DCT has been widely used to generate internal tumor volume (ITV) for a lung tumor for treatment planning. However, lung tumors may show different respiratory motion on the treatment day. The purpose of this study is to evaluate 4D KV conebeam computed tomography (CBCT) for monitoring tumor interfractional motion variation between simulation and each fraction of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: 4D KV CBCT was acquired with the Elekta XVI system. The accuracy of 4D KV CBCT for image-guided radiation therapy (IGRT) was tested with a dynamic thorax motion phantom (CIRS, Virginia) with a linearmore » amplitude of 2 cm. In addition, an adult anthropomorphic phantom (Alderson, Rando) with optically stimulated luminescence (OSL) dosimeters embedded at the center and periphery of a slab of solid water was used to measure the dose of 4D KV CBCT and to compare it with the dose with 3D KV CBCT. The image registration was performed by aligning\\ each phase images of 4D KV CBCT to the planning images and the final couch shifts were calculated as a mean of all these individual shifts along each direction.A workflow was established based on these quality assurance tests for lung cancer patients. Results: 4D KV CBCT does not increase imaging dose in comparison to 3D KV CBCT. Acquisition of 4D KV CBCT is 4 minutes as compared to 2 minutes for 3D KV CBCT. Most of patients showed a small daily variation of tumor respiratory motion about 2 mm. However, some patients may have more than 5 mm variations of tumor respiratory motion. Conclusion: The radiation dose does not increase with 4D KV CBCT. 4D KV CBCT is a useful tool for monitoring interfractional variations of tumor respiratory motion before SBRT of lung cancer patients.« less
The history of stereotactic radiosurgery and radiotherapy.
Lasak, John M; Gorecki, John P
2009-08-01
Stereotactic neurosurgery originated from the pioneering work of Horsley and Clarke, who developed a stereotactic apparatus to study the monkey brain in 1908. Spiegel and Wycis applied this technology to the human brain in 1947, which ultimately lead to the development of multiple stereotactic neurosurgical devices during the 1950s. It was Lars Leksell of Sweden, however, who envisioned stereotactic radiosurgery. Leksell developed the gamma knife to treat intracranial lesions in a noninvasive fashion. His work stimulated worldwide interest and created the field of stereotactic radiosurgery.
Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain
NASA Astrophysics Data System (ADS)
Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.
2017-03-01
MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.
Taschner, Christian A; Le Thuc, Vianney; Reyns, Nicolas; Gieseke, Juergen; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier
2007-10-01
The aim of this study was to develop an algorithm for the integration of time-resolved contrast-enhanced magnetic resonance (MR) angiography into dosimetry planning for Gamma Knife surgery (GKS) of arteriovenous malformations (AVMs) in the brain. Twelve patients harboring brain AVMs referred for GKS underwent intraarterial digital subtraction (DS) angiography and time-resolved MR angiography while wearing an externally applied cranial stereotactic frame. Time-resolved MR angiography was performed on a 1.5-tesla MR unit (Achieva, Philips Medical Systems) using contrast-enhanced 3D fast field echo sequencing with stochastic central k-space ordering. Postprocessing with interactive data language (Research Systems, Inc.) produced hybrid data sets containing dynamic angiographic information and the MR markers necessary for stereotactic transformation. Image files were sent to the Leksell GammaPlan system (Elekta) for dosimetry planning. Stereotactic transformation of the hybrid data sets containing the time-resolved MR angiography information with automatic detection of the MR markers was possible in all 12 cases. The stereotactic coordinates of vascular structures predefined from time-resolved MR angiography matched with DS angiography data in all cases. In 10 patients dosimetry planning could be performed based on time-resolved MR angiography data. In two patients, time-resolved MR angiography data alone were considered insufficient. The target volumes showed a notable shift of centers between modalities. Integration of time-resolved MR angiography data into the Leksell GammaPlan system for patients with brain AVMs is feasible. The proposed algorithm seems concise and sufficiently robust for clinical application. The quality of the time-resolved MR angiography sequencing needs further improvement.
NASA Astrophysics Data System (ADS)
Kishimoto, J.; Lee, D.; St. Lawrence, K.; Romano, W.; Fenster, A.; de Ribaupierre, S.
2013-03-01
Clinical intracranial ultrasound (US) is performed as a standard of care on neonates at risk of intraventricular hemorrhaging (IVH) and is also used after a diagnosis to monitor for potential ventricular dilation. However, it is difficult to estimate the volume of ventricles with 2D US due to their irregular shape. We developed a 3D US system to be used as an adjunct to a clinical system to investigate volumetric changes in the ventricles of neonates with IVH. Our system has been found have an error of within 1% of actual distance measurements in all three directions and volume measurements of manually segmented volumes from phantoms were not statistically significantly different from the actual values (p>0.3). Interobserver volume measurements of the lateral ventricles in a patient with grade III IVH found no significant differences between measurements. There is the potential to use this system in IVH patients to monitor the progression of ventriculomegaly over time.
Brouwers, H Bart; Battey, Thomas W K; Musial, Hayley H; Ciura, Viesha A; Falcone, Guido J; Ayres, Alison M; Vashkevich, Anastasia; Schwab, Kristin; Viswanathan, Anand; Anderson, Christopher D; Greenberg, Steven M; Pomerantz, Stuart R; Ortiz, Claudia J; Goldstein, Joshua N; Gonzalez, R Gilberto; Rosand, Jonathan; Romero, Javier M
2015-09-01
In primary intracerebral hemorrhage, the presence of contrast extravasation after computed tomographic angiography (CTA), termed the spot sign, predicts hematoma expansion and mortality. Because the biological underpinnings of the spot sign are not fully understood, we investigated whether the rate of contrast extravasation, which may reflect the rate of bleeding, predicts expansion and mortality beyond the simple presence of the spot sign. Consecutive intracerebral hemorrhage patients with first-pass CTA followed by a 90-second delayed postcontrast CT (delayed CTA) were included. CTAs were reviewed for spot sign presence by 2 blinded readers. Spot sign volumes on first-pass and delayed CTA and intracerebral hemorrhage volumes were measured using semiautomated software. Extravasation rates were calculated and tested for association with hematoma expansion and mortality using uni- and multivariable logistic regressions. One hundred and sixty-two patients were included, 48 (30%) of whom had ≥1 spot sign. Median spot sign volume was 0.04 mL on first-pass CTA and 0.4 mL on delayed CTA. Median extravasation rate was 0.23 mL/min overall and 0.30 mL/min among expanders versus 0.07 mL/min in nonexpanders. Extravasation rates were also significantly higher in patients who died in hospital: 0.27 mL/min versus 0.04 mL/min. In multivariable analysis, the extravasation rate was independently associated with in-hospital mortality (odds ratio, 1.09 [95% confidence interval, 1.04-1.18], P=0.004), 90-day mortality (odds ratio, 1.15 [95% confidence interval, 1.08-1.27]; P=0.0004), and hematoma expansion (odds ratio, 1.03 [95% confidence interval, 1.01-1.08]; P=0.047). Contrast extravasation rate, or spot sign growth, further refines the ability to predict hematoma expansion and mortality. Our results support the hypothesis that the spot sign directly measures active bleeding in acute intracerebral hemorrhage. © 2015 American Heart Association, Inc.
Sarkar, B; Pradhan, A; Munshi, A
2016-01-01
Linear accelerator (Linac) based stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) using volumetric modulated arc therapy (VMAT) has been used for treating small intracranial lesions. Recent development in the Linacs such as inbuilt micro multileaf collimator (MLC) and flattening filter free (FFF) beam are intended to provide a better dose conformity and faster delivery when using VMAT technique. This study was aimed to compare the dosimetric outcomes and monitor units (MUs) of the stereotactic treatment plans for different commercially available MLC models and beam profiles. Ten patients having 12 planning target volume (PTV)/gross target volume's (GTVs) who received the SRS/SRT treatment in our clinic using Axesse Linac (considered reference arm gold standard) were considered for this study. The test arms comprised of plans using Elekta Agility with FFF, Elekta Agility with the plane beam, Elekta APEX, Varian Millennium 120, Varian Millennium 120HD, and Elekta Synergy in Monaco treatment planning system. Planning constraints and calculation grid spacing were not altered in the test plans. To objectively evaluate the efficacy of MLC-beam model, the resultant dosimetric outcomes were subtracted from the reference arm parameters. V95%, V100%, V105%, D1%, maximum dose, and mean dose of PTV/GTV showed a maximum inter MLC - beam model variation of 1.5% and 2% for PTV and GTV, respectively. Average PTV conformity index and heterogeneity index shows a variation in the range 0.56-0.63 and 1.08-1.11, respectively. Mean dose difference (excluding Axesse) for all organs varied between 1.1 cGy and 74.8 cGy (mean dose = 6.1 cGy standard deviation [SD] = 26.9 cGy) and 1.7 cGy-194.5 cGy (mean dose 16.1 cGy SD = 57.2 cGy) for single and multiple fraction, respectively. The dosimetry of VMAT-based SRS/SRT treatment plan had minimal dependence on MLC and beam model variations. All tested MLC and beam model could fulfil the desired PTV coverage and organs at risk dose constraints. The only notable difference was the halving of the MU for FFF beam as compared to the plane beam. This has the potential to reduce the total patient on couch time by 15% (approximately 2 min).
Li, Y; Xia, Y; Chen, H; Liu, N; Jackson, A; Wintermark, M; Zhang, Y; Hu, J; Wu, B; Zhang, W; Tu, J; Su, Z; Zhu, G
2017-09-01
The contrast volume transfer coefficient ( K trans ), which reflects blood-brain barrier permeability, is influenced by circulation and measurement conditions. We hypothesized that focal low BBB permeability values can predict the spatial distribution of hemorrhagic transformation and global high BBB permeability values can predict the likelihood of hemorrhagic transformation. We retrospectively enrolled 106 patients with hemispheric stroke who received intra-arterial thrombolytic treatment. K trans maps were obtained with first-pass perfusion CT data. The K trans values at the region level, obtained with the Alberta Stroke Program Early CT Score system, were compared to determine the differences between the hemorrhagic transformation and nonhemorrhagic transformation regions. The K trans values of the whole ischemic region based on baseline perfusion CT were obtained as a variable to hemorrhagic transformation possibility at the global level. Forty-eight (45.3%) patients had hemorrhagic transformation, and 21 (19.8%) had symptomatic intracranial hemorrhage. At the region level, there were 82 ROIs with hemorrhagic transformation and parenchymal hemorrhage with a mean K trans , 0.5 ± 0.5/min, which was significantly lower than that in the nonhemorrhagic transformation regions ( P < .01). The mean K trans value of 615 nonhemorrhagic transformation ROIs was 0.7 ± 0.6/min. At the global level, there was a significant difference ( P = .01) between the mean K trans values of patients with symptomatic intracranial hemorrhage (1.3 ± 0.9) and those without symptomatic intracranial hemorrhage (0.8 ± 0.4). Only a high K trans value at the global level could predict the occurrence of symptomatic intracranial hemorrhage ( P < .01; OR = 5.04; 95% CI, 2.01-12.65). Global high K trans values can predict the likelihood of hemorrhagic transformation or symptomatic intracranial hemorrhage at the patient level, whereas focal low K trans values can predict the spatial distributions of hemorrhagic transformation at the region level. © 2017 by American Journal of Neuroradiology.
Medical Department, United States Army. Surgery in World War II. Neurosurgery. Volume 1
1958-01-01
116 Photomicrograph showing petechial hemorrhages in cortex ------------------- 378 117 Photomicrograph showing nerve cell changes in caudate nucleus...headache unrelieved by ordinary medication or when there were signs of increasing intracranial hypertension; and (4) diagnosis of persistent fever ...hemorrhage at various points along the track of the bullet, was almost. invariably present for some days, or even for weeks, after injury. Fever was also
A porcine model of sepsis resulting from the combined insults of hemorrhage and peritonitis.
Parker, S J; Hill, P F; Brown, D; Kenward, C E; Watkins, P E
2000-01-01
The physiological responses to either hemorrhage or sepsis have been well documented, however, their simultaneous delivery, as often seen in penetrating trauma, has not been extensively studied. A terminally-anesthetized porcine model of fixed-volume hemorrhage combined with intraperitoneal sepsis was developed. Large White pigs (45-60 kg) were bled 40% of blood volume and peritonitis was induced using an E. coil (O18:K1:H7) culture. Three groups of animals were sequentially studied. Group A (n = 8) received 10(8) bacteria, and Groups B (n = 4) and C (n = 5) received 10(10) organisms. All animals were maintained on a 2.5 mL/kg/h infusion of 0.9% saline. Group C was autotransfused at 1 h. Animals were monitored for up to 24 h. Cardiovascular features of hypovolemia were recorded in all animals. Animals in Group A improved clinically with little microbiological evidence of systemic sepsis. Group B showed rapid cardiovascular collapse, early E. coil-positive blood cultures, and an early rise in serum TNF-alpha levels. Autotransfusion of Group C significantly improved cardiopulmonary parameters, acid-base status, and survival. A reproducible model of hemorrhage and peritonitis, appropriate for abdominal trauma, which allows investigation of resuscitative and pharmacological interventions has been characterized.
Shimol, Eli Ben; Joskowicz, Leo; Eliahou, Ruth; Shoshan, Yigal
2018-02-01
Stereotactic radiosurgery (SRS) is a common treatment for intracranial meningiomas. SRS is planned on a pre-therapy gadolinium-enhanced T1-weighted MRI scan (Gd-T1w MRI) in which the meningioma contours have been delineated. Post-SRS therapy serial Gd-T1w MRI scans are then acquired for longitudinal treatment evaluation. Accurate tumor volume change quantification is required for treatment efficacy evaluation and for treatment continuation. We present a new algorithm for the automatic segmentation and volumetric assessment of meningioma in post-therapy Gd-T1w MRI scans. The inputs are the pre- and post-therapy Gd-T1w MRI scans and the meningioma delineation in the pre-therapy scan. The output is the meningioma delineations and volumes in the post-therapy scan. The algorithm uses the pre-therapy scan and its meningioma delineation to initialize an extended Chan-Vese active contour method and as a strong patient-specific intensity and shape prior for the post-therapy scan meningioma segmentation. The algorithm is automatic, obviates the need for independent tumor localization and segmentation initialization, and incorporates the same tumor delineation criteria in both the pre- and post-therapy scans. Our experimental results on retrospective pre- and post-therapy scans with a total of 32 meningiomas with volume ranges 0.4-26.5 cm[Formula: see text] yield a Dice coefficient of [Formula: see text]% with respect to ground-truth delineations in post-therapy scans created by two clinicians. These results indicate a high correspondence to the ground-truth delineations. Our algorithm yields more reliable and accurate tumor volume change measurements than other stand-alone segmentation methods. It may be a useful tool for quantitative meningioma prognosis evaluation after SRS.
Yu, Yi-Lin; Yang, Yun-Ju; Lin, Chin; Hsieh, Chih-Chuan; Li, Chiao-Zhu; Feng, Shao-Wei; Tang, Chi-Tun; Chung, Tzu-Tsao; Ma, Hsin-I; Chen, Yuan-Hao; Ju, Da-Tong; Hueng, Dueng-Yuan
2017-01-01
Abstract Tumor control rates of pituitary adenomas (PAs) receiving adjuvant CyberKnife stereotactic radiosurgery (CK SRS) are high. However, there is currently no uniform way to estimate the time course of the disease. The aim of this study was to analyze the volumetric responses of PAs after CK SRS and investigate the application of an exponential decay model in calculating an accurate time course and estimation of the eventual outcome. A retrospective review of 34 patients with PAs who received adjuvant CK SRS between 2006 and 2013 was performed. Tumor volume was calculated using the planimetric method. The percent change in tumor volume and tumor volume rate of change were compared at median 4-, 10-, 20-, and 36-month intervals. Tumor responses were classified as: progression for >15% volume increase, regression for ≤15% decrease, and stabilization for ±15% of the baseline volume at the time of last follow-up. For each patient, the volumetric change versus time was fitted with an exponential model. The overall tumor control rate was 94.1% in the 36-month (range 18–87 months) follow-up period (mean volume change of −43.3%). Volume regression (mean decrease of −50.5%) was demonstrated in 27 (79%) patients, tumor stabilization (mean change of −3.7%) in 5 (15%) patients, and tumor progression (mean increase of 28.1%) in 2 (6%) patients (P = 0.001). Tumors that eventually regressed or stabilized had a temporary volume increase of 1.07% and 41.5% at 4 months after CK SRS, respectively (P = 0.017). The tumor volume estimated using the exponential fitting equation demonstrated high positive correlation with the actual volume calculated by magnetic resonance imaging (MRI) as tested by Pearson correlation coefficient (0.9). Transient progression of PAs post-CK SRS was seen in 62.5% of the patients receiving CK SRS, and it was not predictive of eventual volume regression or progression. A three-point exponential model is of potential predictive value according to relative distribution. An exponential decay model can be used to calculate the time course of tumors that are ultimately controlled. PMID:28121913
The effects of BleedArrest on hemorrhage control in a porcine model.
Gegel, Brian; Burgert, James; Loughren, Michael; Johnson, Don
2012-01-01
The purpose of this study was to examine the effectiveness of the hemostatic agent BleedArrest compared to control. This was a prospective, experimental design employing an established porcine model of uncontrolled hemorrhage. The minimum number of animals (n=10 per group) was used to obtain a statistically valid result. There were no statistically significant differences between the groups (P>.05) indicating that the groups were equivalent on the following parameters: activating clotting time, the subject weights, core body temperatures, amount of one minute hemorrhage, arterial blood pressures, and the amount and percentage of total blood volume. There were significant differences in the amount of hemorrhage (P=.033) between the BleedArrest (mean=72, SD±72 mL) and control (mean=317.30, SD±112.02 mL). BleedArrest is statistically and clinically superior at controlling hemorrhage compared to the standard pressure dressing control group. In conclusion, BleedArrest is an effective hemostatic agent for use in civilian and military trauma management.
Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K
2007-06-01
Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.
Imaging of Hemorrhagic Stroke.
Hakimi, Ryan; Garg, Ankur
2016-10-01
Hemorrhagic stroke comprises approximately 15% to 20% of all strokes. This article provides readers with an understanding of the indications and significance of various neuroimaging techniques available for patients presenting with hemorrhagic strokes of distinct causes. The most common initial neuroimaging study is a noncontrast head CT, which allows for the identification of hemorrhage. Once an intracranial hemorrhage has been identified, the pattern of blood and the patient's medical history, neurologic examination, and laboratory studies lead the practitioner to pursue further neuroimaging studies to guide the medical, surgical, and interventional management. Given that hemorrhagic stroke constitutes a heterogeneous collection of diagnoses, the subsequent neuroimaging pathway necessary to better evaluate and care for these patients is variable based on the etiology.With an increasing incidence and prevalence of atrial fibrillation associated with the aging population and the introduction of three new direct factor Xa inhibitors and one direct thrombin inhibitor to complement vitamin K antagonists, oral anticoagulant use continues to increase. Patients on oral anticoagulants have a sevenfold to tenfold increased risk for intracerebral hemorrhage (ICH). Furthermore, patients who have an ICH associated with oral anticoagulant use have a higher mortality rate than those with primary ICH. Despite the reduced incidence of hypertension-related ICH over the past decade, it is expected that the incidence of ICH will continue to increase. Neuroimaging studies are integral to the identification of hemorrhagic stroke, determination of the underlying etiology, prevention of hematoma expansion, treatment of acute complications, and treatment of the underlying etiology, if indicated. Neuroimaging is essential for prognostication and thus directly impacts patient care.
Outcome of intracerebral hemorrhage associated with different oral anticoagulants
Wilson, Duncan; Seiffge, David J.; Traenka, Christopher; Basir, Ghazala; Purrucker, Jan C.; Rizos, Timolaos; Sobowale, Oluwaseun A.; Sallinen, Hanne; Yeh, Shin-Joe; Wu, Teddy Y.; Ferrigno, Marc; Houben, Rik; Schreuder, Floris H.B.M.; Perry, Luke A.; Tanaka, Jun; Boulanger, Marion; Al-Shahi Salman, Rustam; Jäger, Hans R.; Ambler, Gareth; Shakeshaft, Clare; Yakushiji, Yusuke; Choi, Philip M.C.; Staals, Julie; Cordonnier, Charlotte; Jeng, Jiann-Shing; Veltkamp, Roland; Dowlatshahi, Dar; Engelter, Stefan T.; Parry-Jones, Adrian R.; Meretoja, Atte
2017-01-01
Objective: In an international collaborative multicenter pooled analysis, we compared mortality, functional outcome, intracerebral hemorrhage (ICH) volume, and hematoma expansion (HE) between non–vitamin K antagonist oral anticoagulation–related ICH (NOAC-ICH) and vitamin K antagonist–associated ICH (VKA-ICH). Methods: We compared all-cause mortality within 90 days for NOAC-ICH and VKA-ICH using a Cox proportional hazards model adjusted for age; sex; baseline Glasgow Coma Scale score, ICH location, and log volume; intraventricular hemorrhage volume; and intracranial surgery. We addressed heterogeneity using a shared frailty term. Good functional outcome was defined as discharge modified Rankin Scale score ≤2 and investigated in multivariable logistic regression. ICH volume was measured by ABC/2 or a semiautomated planimetric method. HE was defined as an ICH volume increase >33% or >6 mL from baseline within 72 hours. Results: We included 500 patients (97 NOAC-ICH and 403 VKA-ICH). Median baseline ICH volume was 14.4 mL (interquartile range [IQR] 3.6–38.4) for NOAC-ICH vs 10.6 mL (IQR 4.0–27.9) for VKA-ICH (p = 0.78). We did not find any difference between NOAC-ICH and VKA-ICH for all-cause mortality within 90 days (33% for NOAC-ICH vs 31% for VKA-ICH [p = 0.64]; adjusted Cox hazard ratio (for NOAC-ICH vs VKA-ICH) 0.93 [95% confidence interval (CI) 0.52–1.64] [p = 0.79]), the rate of HE (NOAC-ICH n = 29/48 [40%] vs VKA-ICH n = 93/140 [34%] [p = 0.45]), or functional outcome at hospital discharge (NOAC-ICH vs VKA-ICH odds ratio 0.47; 95% CI 0.18–1.19 [p = 0.11]). Conclusions: In our international collaborative multicenter pooled analysis, baseline ICH volume, hematoma expansion, 90-day mortality, and functional outcome were similar following NOAC-ICH and VKA-ICH. PMID:28381513
Outcome of intracerebral hemorrhage associated with different oral anticoagulants.
Wilson, Duncan; Seiffge, David J; Traenka, Christopher; Basir, Ghazala; Purrucker, Jan C; Rizos, Timolaos; Sobowale, Oluwaseun A; Sallinen, Hanne; Yeh, Shin-Joe; Wu, Teddy Y; Ferrigno, Marc; Houben, Rik; Schreuder, Floris H B M; Perry, Luke A; Tanaka, Jun; Boulanger, Marion; Al-Shahi Salman, Rustam; Jäger, Hans R; Ambler, Gareth; Shakeshaft, Clare; Yakushiji, Yusuke; Choi, Philip M C; Staals, Julie; Cordonnier, Charlotte; Jeng, Jiann-Shing; Veltkamp, Roland; Dowlatshahi, Dar; Engelter, Stefan T; Parry-Jones, Adrian R; Meretoja, Atte; Werring, David J
2017-05-02
In an international collaborative multicenter pooled analysis, we compared mortality, functional outcome, intracerebral hemorrhage (ICH) volume, and hematoma expansion (HE) between non-vitamin K antagonist oral anticoagulation-related ICH (NOAC-ICH) and vitamin K antagonist-associated ICH (VKA-ICH). We compared all-cause mortality within 90 days for NOAC-ICH and VKA-ICH using a Cox proportional hazards model adjusted for age; sex; baseline Glasgow Coma Scale score, ICH location, and log volume; intraventricular hemorrhage volume; and intracranial surgery. We addressed heterogeneity using a shared frailty term. Good functional outcome was defined as discharge modified Rankin Scale score ≤2 and investigated in multivariable logistic regression. ICH volume was measured by ABC/2 or a semiautomated planimetric method. HE was defined as an ICH volume increase >33% or >6 mL from baseline within 72 hours. We included 500 patients (97 NOAC-ICH and 403 VKA-ICH). Median baseline ICH volume was 14.4 mL (interquartile range [IQR] 3.6-38.4) for NOAC-ICH vs 10.6 mL (IQR 4.0-27.9) for VKA-ICH ( p = 0.78). We did not find any difference between NOAC-ICH and VKA-ICH for all-cause mortality within 90 days (33% for NOAC-ICH vs 31% for VKA-ICH [ p = 0.64]; adjusted Cox hazard ratio (for NOAC-ICH vs VKA-ICH) 0.93 [95% confidence interval (CI) 0.52-1.64] [ p = 0.79]), the rate of HE (NOAC-ICH n = 29/48 [40%] vs VKA-ICH n = 93/140 [34%] [ p = 0.45]), or functional outcome at hospital discharge (NOAC-ICH vs VKA-ICH odds ratio 0.47; 95% CI 0.18-1.19 [ p = 0.11]). In our international collaborative multicenter pooled analysis, baseline ICH volume, hematoma expansion, 90-day mortality, and functional outcome were similar following NOAC-ICH and VKA-ICH. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.
Bohoudi, O; Bruynzeel, A M E; Senan, S; Cuijpers, J P; Slotman, B J; Lagerwaard, F J; Palacios, M A
2017-12-01
To implement a robust and fast stereotactic MR-guided adaptive radiation therapy (SMART) online strategy in locally advanced pancreatic cancer (LAPC). SMART strategy for plan adaptation was implemented with the MRIdian system (ViewRay Inc.). At each fraction, OAR (re-)contouring is done within a distance of 3cm from the PTV surface. Online plan re-optimization is based on robust prediction of OAR dose and optimization objectives, obtained by building an artificial neural network (ANN). Proposed limited re-contouring strategy for plan adaptation (SMART 3CM ) is evaluated by comparing 50 previously delivered fractions against a standard (re-)planning method using full-scale OAR (re-)contouring (FULLOAR). Plan quality was assessed using PTV coverage (V 95% , D mean , D 1cc ) and institutional OAR constraints (e.g. V 33Gy ). SMART 3CM required a significant lower number of optimizations than FULLOAR (4 vs 18 on average) to generate a plan meeting all objectives and institutional OAR constraints. PTV coverage with both strategies was identical (mean V 95% =89%). Adaptive plans with SMART 3CM exhibited significant lower intermediate and high doses to all OARs than FULLOAR, which also failed in 36% of the cases to adhere to the V 33Gy dose constraint. SMART 3CM approach for LAPC allows good OAR sparing and adequate target coverage while requiring only limited online (re-)contouring from clinicians. Copyright © 2017 Elsevier B.V. All rights reserved.
Wen, Ning; Kim, Joshua; Doemer, Anthony; Glide-Hurst, Carri; Chetty, Indrin J; Liu, Chang; Laugeman, Eric; Xhaferllari, Ilma; Kumarasiri, Akila; Victoria, James; Bellon, Maria; Kalkanis, Steve; Siddiqui, M Salim; Movsas, Benjamin
2018-06-01
The purpose of this study was to investigate the systematic localization accuracy, treatment planning capability, and delivery accuracy of an integrated magnetic resonance imaging guided Linear Accelerator (MR-Linac) platform for stereotactic radiosurgery. The phantom for the end-to-end test comprises three different compartments: a rectangular MR/CT target phantom, a Winston-Lutz cube, and a rectangular MR/CT isocenter phantom. Hidden target tests were performed at gantry angles of 0, 90, 180, and 270 degrees to quantify the systematic accuracy. Five patient plans with a total of eleven lesions were used to evaluate the dosimetric accuracy. Single-isocenter IMRT treatment plans using 10-15 coplanar beams were generated to treat the multiple metastases. The end-to-end localization accuracy of the system was 1.0 ± 0.1 mm. The conformity index, homogeneity index and gradient index of the plans were 1.26 ± 0.22, 1.22 ± 0.10, and 5.38 ± 1.44, respectively. The average absolute point dose difference between measured and calculated dose was 1.64 ± 1.90%, and the mean percentage of points passing the 3%/1 mm gamma criteria was 96.87%. Our experience demonstrates that excellent plan quality and delivery accuracy was achievable on the MR-Linac for treating multiple brain metastases with a single isocenter. Copyright © 2018 Elsevier B.V. All rights reserved.
Henke, Lauren; Kashani, Rojano; Robinson, Clifford; Curcuru, Austen; DeWees, Todd; Bradley, Jeffrey; Green, Olga; Michalski, Jeff; Mutic, Sasa; Parikh, Parag; Olsen, Jeffrey
2018-03-01
SBRT is used to treat oligometastatic or unresectable primary abdominal malignancies, although ablative dose delivery is limited by proximity of organs-at-risk (OAR). Stereotactic, magnetic resonance (MR)-guided online-adaptive radiotherapy (SMART) may improve SBRT's therapeutic ratio. This prospective Phase I trial assessed feasibility and potential advantages of SMART to treat abdominal malignancies. Twenty patients with oligometastatic or unresectable primary liver (n = 10) and non-liver (n = 10) abdominal malignancies underwent SMART. Initial plans prescribed 50 Gy/5 fractions (BED 100 Gy) with goal 95% PTV coverage by 95% of prescription, subject to hard OAR constraints. Daily real-time online-adaptive plans were created as needed, based on daily setup MR-image-set tumor/OAR "anatomy-of-the-day" to preserve hard OAR constraints, escalate PTV dose, or both. Treatment times, patient outcomes, and dosimetric comparisons between initial and adaptive plans were prospectively recorded. Online adaptive plans were created at time of treatment for 81/97 fractions, due to initial plan violation of OAR constraints (61/97) or observed opportunity for PTV dose escalation (20/97). Plan adaptation increased PTV coverage in 64/97 fractions. Zero Grade ≥ 3 acute (<6 months) treatment-related toxicities were observed. SMART is clinically deliverable and safe, allowing PTV dose escalation and/or simultaneous OAR sparing compared to non-adaptive abdominal SBRT. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
1989-10-01
in Dogs with Hemorrhagic Shock and an Intracranial Mass. Seventh International Symposium on Intracranial Pressure and Brain Injury , Ann Arbor, Michigan...with Hemorrhagic Shock and an Intracranial Mass. Seventh International Symposium on Intracranial Pressure and Brain Injury . Intracranial Pressure VII...and MCI US groups. Discussion: Following this severe insult a iETTiFMT3-a clinical head injury combined wit6i hemorrha Ic shock, a cobntnc/h rcctc
2007-01-01
Combat Critical Care Engineering: Evaluation of Closed Loop Control of Ventilation and Oxygen Flow During Resuscitation in the Compensatory and...Decompensatory Phases of Hemorrhagic Shock: This effort evaluated closed loop control of ventilation and oxygen flow during resuscitation in the...Cerebral Injury Volume, Cerebral Edema, Cerebral Blood Flow and Reactivity, and Histopathology in a Rat Model of Traumatic Brain Injury and Hemorrhagic
Massive transfusion and nonsurgical hemostatic agents.
Perkins, Jeremy G; Cap, Andrew P; Weiss, Brendan M; Reid, Thomas J; Bolan, Charles D; Bolan, Charles E
2008-07-01
Hemorrhage in trauma is a significant challenge, accounting for 30% to 40% of all fatalities, second only to central nervous system injury as a cause of death. However, hemorrhagic death is the leading preventable cause of mortality in combat casualties and typically occurs within 6 to 24 hrs of injury. In cases of severe hemorrhage, massive transfusion may be required to replace more than the entire blood volume. Early prediction of massive transfusion requirements, using clinical and laboratory parameters, combined with aggressive management of hemorrhage by surgical and nonsurgical means, has significant potential to reduce early mortality. Although the classification of massive transfusion varies, the most frequently used definition is ten or more units of blood in 24 hrs. Transfusion of red blood cells is intended to restore blood volume, tissue perfusion, and oxygen-carrying capacity; platelets, plasma, and cryoprecipitate are intended to facilitate hemostasis through prevention or treatment of coagulopathy. Massive transfusion is uncommon in civilian trauma, occurring in only 1% to 3% of trauma admissions. As a result of a higher proportion of penetrating injury in combat casualties, it has occurred in approximately 8% of Operation Iraqi Freedom admissions and in as many as 16% during the Vietnam conflict. Despite its potential to reduce early mortality, massive transfusion is not without risk. It requires extensive blood-banking resources and is associated with high mortality. This review describes the clinical problems associated with massive transfusion and surveys the nonsurgical management of hemorrhage, including transfusion of blood products, use of hemostatic bandages/agents, and treatment with hemostatic medications.
Huang, Hong-Xiang; Yao, Yi-Bo; Tang, Ying
2016-01-01
The aim of the present study was to examine the clinical value of ‘tying, binding and fixing operation’ in treating severe mixed hemorrhoids. A total of 160 patients with severe mixed hemorrhoids were selected and randomly divided into the experimental (n=80) and control (n=80) groups. The groups were treated using ‘tying, binding and fixing operation’ and Doppler ultrasound-guided hemorrhoidal artery ligation (DG-HAL), respectively. The results showed that the average operative time of the experimental group (35.57±6.17) was significantly higher than that of the control group (12.73±4.92). There was no significant difference of blood loss during the operation between the two groups (P>0.05). There was also no significant difference in improving the hemorrhage symptom between the two groups (P>0.05). In addition, concerning improvement of prolapse symptoms and reduction of the volume of hemorrhoids, the experimental group were significantly improved as compared to the control group. No anal function damage in the two groups was identified, and the length of stay in hospital for the two groups was not significantly different (P>0.05). However, the hospitalization cost in the experimental group (5,334.77±875.54) was significantly lower than that of the control group (8,551.81±1,806.54) and satisfaction degree was significantly higher than that of the control group. The incidences of perianal pain, anal edema and dysuria between two groups were not significantly different (P>0.05). There were 10 cases of secondary hemorrhage and 18 cases of infection in the experimental group, and 12 cases of secondary hemorrhage and 14 cases of infection in the control group, although the differences between the two groups were not statistically significant (P>0.05). The incidence rate of local hematoma in the experimental group (1.2%) was significantly lower than that in the control group (15.0%). The recurrence rate of the control group (22.5%) was also significantly higher than that of the experimental group (2.5%). In conclusion, tying, binding and fixing operation is a promising method that may be employed for the treatment of sever mixed hemorrhoids, and it is better than DG-HAL in improving the prolapse and reducing the volume of hemorrhoids. PMID:27446315
Chen, Ching-Jen; Ding, Dale; Wang, Tony R; Buell, Thomas J; Ilyas, Adeel; Ironside, Natasha; Lee, Cheng-Chia; Kalani, M Yashar; Park, Min S; Liu, Kenneth C; Sheehan, Jason P
2018-05-12
Microsurgery (MS) and stereotactic radiosurgery (SRS) remain the preferred interventions for the curative treatment of brain arteriovenous malformations (AVM), but their relative efficacy remains incompletely defined. To compare the outcomes of MS to SRS for AVMs through a retrospective, matched cohort study. We evaluated institutional databases of AVM patients who underwent MS and SRS. MS-treated patients were matched, in a 1:1 ratio based on patient and AVM characteristics, to SRS-treated patients. Statistical analyses were performed to compare outcomes data between the 2 cohorts. The primary outcome was defined as AVM obliteration without a new permanent neurological deficit. The matched MS and SRS cohorts were each comprised of 59 patients. Both radiological (85 vs 11 mo; P < .001) and clinical (92 vs 12 mo; P < .001) follow-up were significantly longer for the SRS cohort. The primary outcome was achieved in 69% of each cohort. The MS cohort had a significantly higher obliteration rate (98% vs 72%; P = .001), but also had a significantly higher rate of new permanent deficit (31% vs 10%; P = .011). The posttreatment hemorrhage rate was significantly higher for the SRS cohort (10% for SRS vs 0% for MS; P = .027). In subgroup analyses of ruptured and unruptured AVMs, no significant differences between the primary outcomes were observed. For patients with comparable AVMs, MS and SRS afford similar rates of deficit-free obliteration. Nidal obliteration is more frequently achieved with MS, but this intervention also incurs a greater risk of new permanent neurological deficit.
Severe Postpartum Hemorrhage from Uterine Atony: A Multicentric Study
Montufar-Rueda, Carlos; Rodriguez, Laritza; Jarquin, José Douglas; Barboza, Alejandra; Bustillo, Maura Carolina; Marin, Flor; Ortiz, Guillermo; Estrada, Francisco
2013-01-01
Objective. Postpartum hemorrhage (PPH) is an important cause of maternal mortality (MM) around the world. Seventy percent of the PPH corresponds to uterine atony. The objective of our study was to evaluate multicenter PPH cases during a 10-month period, and evaluate severe postpartum hemorrhage management. Study Design. The study population is a cohort of vaginal delivery and cesarean section patients with severe postpartum hemorrhage secondary to uterine atony. The study was designed as a descriptive, prospective, longitudinal, and multicenter study, during 10 months in 13 teaching hospitals. Results. Total live births during the study period were 124,019 with 218 patients (0.17%) with severe postpartum hemorrhage (SPHH). Total maternal deaths were 8, for mortality rate of 3.6% and a MM rate of 6.45/100,000 live births (LB). Maternal deaths were associated with inadequate transfusion therapy. Conclusions. In all patients with severe hemorrhage and subsequent hypovolemic shock, the most important therapy is intravascular volume resuscitation, to reduce the possibility of target organ damage and death. Similarly, the current proposals of transfusion therapy in severe or massive hemorrhage point to early transfusion of blood products and use of fresh frozen plasma, in addition to packed red blood cells, to prevent maternal deaths. PMID:24363935
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, Jun; Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland; Huang, Judy
Purpose: Stereotactic radiation surgery (SRS) is one of the therapeutic modalities currently available to treat cerebral arteriovenous malformations (AVM). Conventionally, magnetic resonance imaging (MRI) and MR angiography (MRA) and digital subtraction angiography (DSA) are used in combination to identify the target volume for SRS treatment. The purpose of this study was to evaluate the use of C-arm cone beam computed tomography (CBCT) in the treatment planning of SRS for cerebral AVMs. Methods and Materials: Sixteen consecutive patients treated for brain AVMs at our institution were included in this retrospective study. Prior to treatment, all patients underwent MRA, DSA, and C-arm CBCT.more » All images were coregistered using the GammaPlan planning system. AVM regions were delineated independently by 2 physicians using either C-arm CBCT or MRA, resulting in 2 volumes: a CBCT volume (VCBCT) and an MRA volume (V{sub MRA}). SRS plans were generated based on the delineated regions. Results: The average volume of treatment targets delineated using C-arm CBCT and MRA were similar, 6.40 cm{sup 3} and 6.98 cm{sup 3}, respectively (P=.82). However, significant regions of nonoverlap existed. On average, the overlap of the MRA with the C-arm CBCT was only 52.8% of the total volume. In most cases, radiation plans based on V{sub MRA} did not provide adequate dose to the region identified on C-arm CBCT; the mean minimum dose to V{sub CBCT} was 29.5%, whereas the intended goal was 45% (P<.001). The mean volume of normal brain receiving 12 Gy or more in C-arm CBCT-based plans was not greater than in the MRA-based plans. Conclusions: Use of C-arm CBCT images significantly alters the delineated regions of AVMs for SRS planning, compared to that of MRA/MRI images. CT-based planning can be accomplished without increasing the dose to normal brain and may represent a more accurate definition of the nidus, increasing the chances for successful obliteration.« less
Measurement of Total Scatter Factor for Stereotactic Cones with Plastic Scintillation Detector
Chaudhari, Suresh H; Dobhal, Rishabh; Kinhikar, Rajesh A.; Kadam, Sudarshan S.; Deshpande, Deepak D.
2017-01-01
Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be −1.3%, 1.9%, −0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data. PMID:28405102
Measurement of Total Scatter Factor for Stereotactic Cones with Plastic Scintillation Detector.
Chaudhari, Suresh H; Dobhal, Rishabh; Kinhikar, Rajesh A; Kadam, Sudarshan S; Deshpande, Deepak D
2017-01-01
Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx ™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be -1.3%, 1.9%, -0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data.
Tuleasca, Constantin; Najdenovska, Elena; Régis, Jean; Witjas, Tatiana; Girard, Nadine; Champoudry, Jérôme; Faouzi, Mohamed; Thiran, Jean-Philippe; Cuadra, Meritxell Bach; Levivier, Marc; Van De Ville, Dimitri
2018-03-01
Essential tremor (ET) is the most common movement disorder. Drug-resistant ET can benefit from standard surgical stereotactic procedures (deep brain stimulation, thalamotomy) or minimally invasive high-intensity focused ultrasound (HIFU) or stereotactic radiosurgical thalamotomy (SRS-T). Resting-state fMRI (rs-fMRI) is a non-invasive imaging method acquired in absence of a task. We examined whether rs-fMRI correlates with tremor score on the treated hand (TSTH) improvement 1 year after SRS-T. We included 17 consecutive patients treated with left unilateral SRS-T in Marseille, France. Tremor score evaluation and rs-fMRI were acquired at baseline and 1 year after SRS-T. Resting-state data (34 scans) were analyzed without a priori hypothesis, in Lausanne, Switzerland. Based on degree of improvement in TSTH, to consider SRS-T at least as effective as medication, we separated two groups: 1, ≤ 50% (n = 6, 35.3%); 2, > 50% (n = 11, 64.7%). They did not differ statistically by age (p = 0.86), duration of symptoms (p = 0.41), or lesion volume at 1 year (p = 0.06). We report TSTH improvement correlated with interconnectivity strength between salience network with the left claustrum and putamen, as well as between bilateral motor cortices, frontal eye fields and left cerebellum lobule VI with right visual association area (the former also with lesion volume). Longitudinal changes showed additional associations in interconnectivity strength between right dorsal attention network with ventro-lateral prefrontal cortex and a reminiscent salience network with fusiform gyrus. Brain connectivity measured by resting-state fMRI relates to clinical response after SRS-T. Relevant networks are visual, motor, and attention. Interconnectivity between visual and motor areas is a novel finding, revealing implication in movement sensory guidance.
Pappas, E P; Seimenis, I; Moutsatsos, A; Georgiou, E; Nomikos, P; Karaiskos, P
2016-10-07
This work provides characterization of system-related geometric distortions present in MRIs used in Gamma Knife (GK) stereotactic radiosurgery (SRS) treatment planning. A custom-made phantom, compatible with the Leksell stereotactic frame model G and encompassing 947 control points (CPs), was utilized. MR images were obtained with and without the frame, thus allowing discrimination of frame-induced distortions. In the absence of the frame and following compensation for field inhomogeneities, measured average CP disposition owing to gradient nonlinearities was 0.53 mm. In presence of the frame, contrarily, detected distortion was greatly increased (up to about 5 mm) in the vicinity of the frame base due to eddy currents induced in the closed loop of its aluminum material. Frame-related distortion was obliterated at approximately 90 mm from the frame base. Although the region with the maximum observed distortion may not lie within the GK treatable volume, the presence of the frame results in distortion of the order of 1.5 mm at a 7 cm distance from the center of the Leksell space. Additionally, severe distortions observed outside the treatable volume could possibly impinge on the delivery accuracy mainly by adversely affecting the registration process (e.g. the position of the lower part of the N-shaped fiducials used to define the stereotactic space may be miss-registered). Images acquired with a modified version of the frame developed by replacing its front side with an acrylic bar, thus interrupting the closed aluminum loop and reducing the induced eddy currents, were shown to benefit from relatively reduced distortion. System-related distortion was also identified in patient MR images. Using corresponding CT angiography images as a reference, an offset of 1.1 mm was detected for two vessels lying in close proximity to the frame base, while excellent spatial agreement was observed for a vessel far apart from the frame base.
NASA Astrophysics Data System (ADS)
Pappas, E. P.; Seimenis, I.; Moutsatsos, A.; Georgiou, E.; Nomikos, P.; Karaiskos, P.
2016-10-01
This work provides characterization of system-related geometric distortions present in MRIs used in Gamma Knife (GK) stereotactic radiosurgery (SRS) treatment planning. A custom-made phantom, compatible with the Leksell stereotactic frame model G and encompassing 947 control points (CPs), was utilized. MR images were obtained with and without the frame, thus allowing discrimination of frame-induced distortions. In the absence of the frame and following compensation for field inhomogeneities, measured average CP disposition owing to gradient nonlinearities was 0.53 mm. In presence of the frame, contrarily, detected distortion was greatly increased (up to about 5 mm) in the vicinity of the frame base due to eddy currents induced in the closed loop of its aluminum material. Frame-related distortion was obliterated at approximately 90 mm from the frame base. Although the region with the maximum observed distortion may not lie within the GK treatable volume, the presence of the frame results in distortion of the order of 1.5 mm at a 7 cm distance from the center of the Leksell space. Additionally, severe distortions observed outside the treatable volume could possibly impinge on the delivery accuracy mainly by adversely affecting the registration process (e.g. the position of the lower part of the N-shaped fiducials used to define the stereotactic space may be miss-registered). Images acquired with a modified version of the frame developed by replacing its front side with an acrylic bar, thus interrupting the closed aluminum loop and reducing the induced eddy currents, were shown to benefit from relatively reduced distortion. System-related distortion was also identified in patient MR images. Using corresponding CT angiography images as a reference, an offset of 1.1 mm was detected for two vessels lying in close proximity to the frame base, while excellent spatial agreement was observed for a vessel far apart from the frame base.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fritz, Peter, E-mail: p.h.fritz@t-online.d; Kraus, Hans-Joerg; Muehlnickel, Werner
2010-09-01
Purpose: To demonstrate the feasibility of complete target immobilization by means of high-frequency jet ventilation (HFJV); and to show that the saving of planning target volume (PTV) on the stereotactic body radiation therapy (SBRT) under HFJV, compared with SBRT with respiratory motion, can be predicted with reliable accuracy by computed tomography (CT) scans at peak inspiration phase. Methods and Materials: A comparison regarding different methods for defining the PTV was carried out in 22 patients with tumors that clearly moved with respiration. A movement span of the gross tumor volume (GTV) was defined by fusing respiration-correlated CT scans. The PTVmore » enclosed the GTV positions with a safety margin throughout the breathing cycle. To create a PTV from CT scans acquired under HFJV, the same margins were drawn around the immobilized target. In addition, peak inspiration phase CT images (PIP-CTs) were used to approximate a target immobilized by HFJV. Results: The resulting HFJV-PTVs were between 11.6% and 45.4% smaller than the baseline values calculated as respiration-correlated CT-PTVs (median volume reduction, 25.4%). Tentative planning by means of PIP-CT PTVs predicted that in 19 of 22 patients, use of HFJV would lead to a reduction in volume of {>=}20%. Using this threshold yielded a positive predictive value of 0.89, as well as a sensitivity of 0.94 and a specificity of 0.5. Conclusions: In all patients, SBRT under HFJV provided a reliable immobilization of the GTVs and achieved a reduction in PTVs, regardless of patient compliance. Tentative planning facilitated the selection of patients who could better undergo radiation in respiratory standstill, both with greater accuracy and lung protection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Huixiao; Lohr, Frank; Fritz, Peter
2010-11-01
Purpose: Dose calculation based on pencil beam (PB) algorithms has its shortcomings predicting dose in tissue heterogeneities. The aim of this study was to compare dose distributions of clinically applied non-intensity-modulated radiotherapy 15-MV plans for stereotactic body radiotherapy between voxel Monte Carlo (XVMC) calculation and PB calculation for lung lesions. Methods and Materials: To validate XVMC, one treatment plan was verified in an inhomogeneous thorax phantom with EDR2 film (Eastman Kodak, Rochester, NY). Both measured and calculated (PB and XVMC) dose distributions were compared regarding profiles and isodoses. Then, 35 lung plans originally created for clinical treatment by PB calculationmore » with the Eclipse planning system (Varian Medical Systems, Palo Alto, CA) were recalculated by XVMC (investigational implementation in PrecisePLAN [Elekta AB, Stockholm, Sweden]). Clinically relevant dose-volume parameters for target and lung tissue were compared and analyzed statistically. Results: The XVMC calculation agreed well with film measurements (<1% difference in lateral profile), whereas the deviation between PB calculation and film measurements was up to +15%. On analysis of 35 clinical cases, the mean dose, minimal dose and coverage dose value for 95% volume of gross tumor volume were 1.14 {+-} 1.72 Gy, 1.68 {+-} 1.47 Gy, and 1.24 {+-} 1.04 Gy lower by XVMC compared with PB, respectively (prescription dose, 30 Gy). The volume covered by the 9 Gy isodose of lung was 2.73% {+-} 3.12% higher when calculated by XVMC compared with PB. The largest differences were observed for small lesions circumferentially encompassed by lung tissue. Conclusions: Pencil beam dose calculation overestimates dose to the tumor and underestimates lung volumes exposed to a given dose consistently for 15-MV photons. The degree of difference between XVMC and PB is tumor size and location dependent. Therefore XVMC calculation is helpful to further optimize treatment planning.« less
Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang Zheng; Wang Zhiheng; Wu, Q. Jackie
A new Novalis Tx system equipped with a high definition multileaf collimator (HDMLC) recently became available to perform both image-guided radiosurgery and conventional radiotherapy. It is capable of delivering a highly conformal radiation dose with three energy modes: 6 MV photon energy, 15 MV photon energy, and 6 MV photon energy in a stereotactic radiosurgery mode with 1000 MU/min dose rate. Dosimetric characteristics of the new Novalis Tx treatment unit with the HDMLC are systematically measured for commissioning. A high resolution diode detector and miniion-chamber detector are used to measure dosimetric data for a range of field sizes from 4x4more » mm to 400x400 mm. The commissioned Novalis Tx system has passed the RPC stereotactic radiosurgery head phantom irradiation test. The Novalis Tx system not only expands its capabilities with three energy modes, but also achieves better beam conformity and sharer beam penumbra with HDMLC. Since there is little beam data information available for the new Novalis Tx system, we present in this work the dosimetric data of the new modality for reference and comparison.« less
NASA Astrophysics Data System (ADS)
Rau, Thomas S.; Lexow, G. Jakob; Blume, Denise; Kluge, Marcel; Lenarz, Thomas; Majdani, Omid
2017-03-01
A new method for template-guided cochlear implantation surgery is proposed which has been developed to create a minimally invasive access to the inner ear. A first design of the surgical template was drafted, built, and finally tested regarding its accuracy. For individual finalization of the micro-stereotactic frame bone cement is utilized as this well-known and well-established material suggests ease of use as well as high clinical acceptance and enables both sterile and rapid handling. The new concept includes an alignment device, based on a passive hexapod with manually adjustable legs for temporary fixation of the separate parts in the patient-specific pose until the bone cement is spread and finally cured. Additionally, a corresponding evaluation method was developed to determine the accuracy of the microstereotactic frame in some initial experiments. In total 18 samples of the surgical template were fabricated based on previously planned trajectories. The mean positioning error at the target point was 0.30 mm with a standard deviation of 0.25 mm.
Karsy, Michael; Patel, Daxa M; Bollo, Robert J
2018-05-01
Magnetic resonance imaging-guided stereotactic laser ablation of intracranial targets, including brain tumors, has expanded dramatically over the past decade, but there have been few reports of complications, especially those occurring in a delayed fashion. Laser ablation of subependymal giant cell astrocytomas (SEGAs) is an attractive alternative to maintenance immunotherapy in some children with tuberous sclerosis complex (TSC); however, the effect of treatment on disease progression and the nature and frequency of potential complications remains largely unknown. The authors report the case of a 5-year-old boy with TSC who underwent stereotactic laser ablation of a SEGA at the right foramen of Monro on 2 separate occasions. After the second ablation, immediate posttreatment MRI revealed gadolinium extravasation from the tumor into the lateral ventricle. Nine months later, the patient presented with papilledema and delayed obstructive hydrocephalus secondary to intraventricular adhesions causing a trapped right lateral ventricle. This was successfully treated with endoscopic septostomy. The authors discuss the potential cause and clinical management of a delayed complication not previously reported after a relatively novel surgical therapy.
BiopSee® - transperineal stereotactic navigated prostate biopsy.
Zogal, Pawel; Sakas, Georgios; Rösch, Woerner; Baltas, Dimos
2011-06-01
In the recent years, prostate cancer was the most commonly diagnosed cancer in men. Currently secure diagnosis confirmation is done by a transrectal biopsy and following histopathological examination. Conventional transrectal biopsy success rates are rather low with ca. 30% detection upon the first and ca 20% after re-biopsy. The paper presents a novel system for stereotactic navigated prostate biopsy. The approach results into higher accuracy, reproducibility and unrestricted and effective access to all prostate regions. Custom designed ultrasound, new template design and integrated 2-axes stepper allows superior 2D and 3D prostate imaging quality and precise needle navigation. DICOM functionality and image fusion enable to import pre-operative datasets (e.g. multiparametric MRI, targets etc.) and overlay all available radiological information into the biopsy planning and guiding procedure. The biopsy needle insertion itself is performed under augmented reality ultrasound guidance. Each procedure step is automatically documented in order to provide quality assurance and permit data re-usage for the further treatment. First clinical results indicates success rates of ca. 70% by first biopsies by our approach.
Papagiannis, P; Karaiskos, P; Kozicki, M; Rosiak, J M; Sakelliou, L; Sandilos, P; Seimenis, I; Torrens, M
2005-05-07
This work seeks to verify multi-shot clinical applications of stereotactic radiosurgery with a Leksell Gamma Knife model C unit employing a polymer gel-MRI based experimental procedure, which has already been shown to be capable of verifying the precision and accuracy of dose delivery in single-shot gamma knife applications. The treatment plan studied in the present work resembles a clinical treatment case of pituitary adenoma using four 8 mm and one 14 mm collimator helmet shots to deliver a prescription dose of 15 Gy to the 50% isodose line (30 Gy maximum dose). For the experimental dose verification of the treatment plan, the same criteria as those used in the clinical treatment planning evaluation were employed. These included comparison of measured and GammaPlan calculated data, in terms of percentage isodose contours on axial, coronal and sagittal planes, as well as 3D plan evaluation criteria such as dose-volume histograms for the target volume, target coverage and conformity indices. Measured percentage isodose contours compared favourably with calculated ones despite individual point fluctuations at low dose contours (e.g., 20%) mainly due to the effect of T2 measurement uncertainty on dose resolution. Dose-volume histogram data were also found in a good agreement while the experimental results for the percentage target coverage and conformity index were 94% and 1.17 relative to corresponding GammaPlan calculations of 96% and 1.12, respectively. Overall, polymer gel results verified the planned dose distribution within experimental uncertainties and uncertainty related to the digitization process of selected GammaPlan output data.
Higuchi, Yoshinori; Nagano, Osamu; Sato, Yasunori; Yamamoto, Masaaki; Ono, Junichi; Saeki, Naokatsu; Miyakawa, Akifumi; Hirai, Tatsuo
2012-01-01
Objective The Japan Leksell Gamma Knife (JLGK) Society has conducted a prospective multi-institute study (JLGK0901, UNIN000001812) for selected patients in order to prove the effectiveness of stereotactic radiosurgery (SRS) alone using the gamma knife (GK) for 1-10 brain lesions. Herein, we verify the validity of 5 major patient selection criteria for the JLGK0901 trial. Materials and Methods Between 1998 and 2010, 2246 consecutive cases with 10352 brain metastases treated with GK were analyzed to determine the validity of the following 5 major JLGK0901 criteria; 1) 1-10 brain lesions, 2) less than 10 cm3 volume of the largest tumor, 3) no more than 15 cm3 total tumor volume, 4) no cerebrospinal fluid (CSF) dissemination, 5) Karnofsky performance status (KPS) score ≥70. Results For cases with >10 brain metastases, salvage treatments for new lesions were needed more frequently. The tumor control rate for lesions larger than 10 cm3 was significantly lower than that of tumors <10 cm3. Overall, neurological and qualitative survivals (OS, NS, QS) of cases with >15 cm3 total tumor volume or positive magnetic resonance imaging findings of CSF were significantly poorer. Outcomes in cases with KPS <70 were significantly poorer in terms of OS. Conclusion Our retrospective results of 2246 GK-treated cases verified the validity of the 5 major JLGK0901 criteria. The inclusion criteria for the JLGK0901 study are appearently good indications for SRS. PMID:29296339
Interobserver delineation variation in lung tumour stereotactic body radiotherapy
Persson, G F; Nygaard, D E; Hollensen, C; Munck af Rosenschöld, P; Mouritsen, L S; Due, A K; Berthelsen, A K; Nyman, J; Markova, E; Roed, A P; Roed, H; Korreman, S; Specht, L
2012-01-01
Objectives In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design. Methods 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three radiologists independently delineated the gross tumour volume. The interobserver variation was calculated as a mean of multiple SDs of distances to a reference contour, and calculated for the transversal plane (SDtrans) and craniocaudal (CC) direction (SDcc) separately. Concordance indexes and volume deviations were also calculated. Results Median tumour volume was 13.0 cm3, ranging from 0.3 to 60.4 cm3. The mean SDtrans was 0.15 cm (SD 0.08 cm) and the overall mean SDcc was 0.26 cm (SD 0.15 cm). Tumours with pleural contact had a significantly larger SDtrans than tumours surrounded by lung tissue. Conclusions The interobserver delineation variation was very small in this systematic cross-sectional analysis, although significantly larger in the CC direction than in the transversal plane, stressing that anisotropic margins should be applied. This study is the first to make a systematic cross-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours. PMID:22919015
Karlsson, Kristin; Nyman, Jan; Baumann, Pia; Wersäll, Peter; Drugge, Ninni; Gagliardi, Giovanna; Johansson, Karl-Axel; Persson, Jan-Olov; Rutkowska, Eva; Tullgren, Owe; Lax, Ingmar
2013-11-01
To evaluate the dose-response relationship between radiation-induced atelectasis after stereotactic body radiation therapy (SBRT) and bronchial dose. Seventy-four patients treated with SBRT for tumors close to main, lobar, or segmental bronchi were selected. The association between incidence of atelectasis and bronchial dose parameters (maximum point-dose and minimum dose to the high-dose bronchial volume [ranging from 0.1 cm(3) up to 2.0 cm(3)]) was statistically evaluated with survival analysis models. Prescribed doses varied between 4 and 20 Gy per fraction in 2-5 fractions. Eighteen patients (24.3%) developed atelectasis considered to be radiation-induced. Statistical analysis showed a significant correlation between the incidence of radiation-induced atelectasis and minimum dose to the high-dose bronchial volumes, of which 0.1 cm(3) (D(0.1cm3)) was used for further analysis. The median value of D(0.1cm3) (α/β = 3 Gy) was EQD(2,LQ) = 147 Gy3 (range, 20-293 Gy3). For patients who developed atelectasis the median value was EQD(2,LQ) = 210 Gy3, and for patients who did not develop atelectasis, EQD(2,LQ) = 105 Gy3. Median time from treatment to development of atelectasis was 8.0 months (range, 1.1-30.1 months). In this retrospective study a significant dose-response relationship between the incidence of atelectasis and the dose to the high-dose volume of the bronchi is shown. Copyright © 2013 Elsevier Inc. All rights reserved.
Stereotactic radiosurgery - discharge
Gamma knife - discharge; Cyberknife - discharge; Stereotactic radiotherapy - discharge; Fractionated stereotactic radiotherapy - discharge; Cyclotrons - discharge; Linear accelerator - discharge; Lineacs - discharge; Proton beam radiosurgery - discharge
Experience of Soviet Medicine in a Great Patriotic War, 1941-1945. Volume 16, Section 1.
1980-10-22
of artery), but sometimes it is also in the aneurysmatic ones (through the lateral blood circulation). Anamnesis is even more inaccurate" I. FOOTNOTE...and power of observation, so that on the basis of anamnesis (strong hemorrhage after injury, fainting, use/application of a tourniluet) and it is...hemorrhage or other clear signs of vascular damage are present,. However, this requires considerable attention and experiment/experience, if in anamnesis
1992-08-01
Dextran Metabolism in Dehydrated, Hemorrhaged Sheep Infused with Hypertonic Saline/Dextran (HSD). 3 J. Eaker (Davis, U.S.A.): Small Volume Intraosseous ...S. Majluf (Mexico City, Mexico): Eualuation of an Intraosseous Function versus Intrauenous and Central Catheter in Patients with Hemorrhagic Shock. W...between the traumatized brain parenchyma and the skull bone followed by closure of the cranium by dental cement. At 20 hrs later the animals were
Prostate cancer patients who have failed standard radiation therapy have the options of surgery, radioactive seed implantation or cryoablation. Deborah Citrin, M.D., of the Radiation Oncology Branch is leading a study of stereotactic body radiation therapy (SBRT) to treat prostate cancer that has recurred locally after standard radiation therapy. The goal of this study is to use a novel imaging approach to guide treatment and to define the best dose of SBRT for patients whose prostate cancer has recurred after standard radiotherapy. Read more...
Gérard, M; Jumeau, R; Pichon, B; Biau, J; Blais, E; Horion, J; Noël, G
2017-10-01
Cerebral radiation-induced toxicities after radiotherapy (RT) of brain tumors are frequent. The protection of organs at risk (OAR) is crucial, especially for brain tumors, to preserve cognition in cancer survivors. Dose constraints of cerebral OAR used in conventional RT, radiosurgery (SRS) and stereotactic radiotherapy (SRT) are debated. In fact, they are based on historical cohorts or calculated with old mathematical models. Values of α/β ratio of cerebral OAR are also controversial leading to misestimate the equivalent dose in 2Gy fractions or the biological equivalent dose, especially during hypofractionated RT. Although recent progresses in medical imaging, the diagnosis of radionecrosis remains difficult. In this article, we propose a large review of dose constraints used for three major cerebral OAR: the brain stem, the hippocampus and the brain. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Radiosurgery with a linear accelerator. Methodological aspects.
Betti, O O; Galmarini, D; Derechinsky, V
1991-01-01
Based on the concepts of Leksell and on recommendations of different Swedish physicists on the use of linear accelerator for radiosurgical use, we developed a new methodology coupling the Talairach stereotactic system with a commercial linac. Anatomical facts encouraged us to use coronal angles of irradiation employing the angular displacement of the linac above the horizontal plane. Different coronal planes are obtained by rotation of the stereotactic frame. The center of the irradiated target coincides with the irradiation and rotation center of the linear accelerator. Multiple targets can be irradiated in the same session. We use as recommended a secondary collimator in heavy alloy. Special software was prepared after different dosimetric controls. The use of a PC allows us to employ 1-6 targets and different collimators to displace the isocenters in order to obtain geometrical isodose modification, and to change the value of each irradiation arc or portions of each arc in some minutes. Simple or sophisticated neurosurgical strategies can be applied in the treatment of frequently irregular shape and volume AVMs.
Patel, Nitesh V; Mian, Matthew; Stafford, R Jason; Nahed, Brian V; Willie, Jon T; Gross, Robert E; Danish, Shabbar F
2016-12-01
Laser-induced thermal therapy has become a powerful tool in the neurosurgical armamentarium. The physics of laser therapy are complex, but a sound understanding of this topic is clinically relevant, as many centers have incorporated it into their treatment algorithm, and educated patients are demanding consideration of its use for their disease. Laser ablation has been used for a wide array of intracranial lesions. Laser catheter placement is guided by stereotactic planning; however, as the procedure has popularized, the number of ways in which the catheter can be inserted has also increased. There are many technical nuances for laser placement, and, to date, there is not a clear understanding of whether any one technique is better than the other. In this review, we describe the basic physics of magnetic resonance-guided laser-induced thermal therapy and describe the several common techniques for accurate Visualase laser catheter placement in a stepwise fashion. MRg-LITT, magnetic resonance-guided laser-induced thermal therapyPAD, precision aiming device.
10 CFR 35.645 - Periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Periodic spot-checks for gamma stereotactic radiosurgery... § 35.645 Periodic spot-checks for gamma stereotactic radiosurgery units. (a) A licensee authorized to use a gamma stereotactic radiosurgery unit for medical use shall perform spot-checks of each gamma...
10 CFR 35.645 - Periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Periodic spot-checks for gamma stereotactic radiosurgery... § 35.645 Periodic spot-checks for gamma stereotactic radiosurgery units. (a) A licensee authorized to use a gamma stereotactic radiosurgery unit for medical use shall perform spot-checks of each gamma...
10 CFR 35.645 - Periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Periodic spot-checks for gamma stereotactic radiosurgery... § 35.645 Periodic spot-checks for gamma stereotactic radiosurgery units. (a) A licensee authorized to use a gamma stereotactic radiosurgery unit for medical use shall perform spot-checks of each gamma...
10 CFR 35.645 - Periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Periodic spot-checks for gamma stereotactic radiosurgery... § 35.645 Periodic spot-checks for gamma stereotactic radiosurgery units. (a) A licensee authorized to use a gamma stereotactic radiosurgery unit for medical use shall perform spot-checks of each gamma...
10 CFR 35.645 - Periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Periodic spot-checks for gamma stereotactic radiosurgery... § 35.645 Periodic spot-checks for gamma stereotactic radiosurgery units. (a) A licensee authorized to use a gamma stereotactic radiosurgery unit for medical use shall perform spot-checks of each gamma...
10 CFR 35.2645 - Records of periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Records of periodic spot-checks for gamma stereotactic... MATERIAL Records § 35.2645 Records of periodic spot-checks for gamma stereotactic radiosurgery units. (a) A... and intercom systems, timer termination, treatment table retraction mechanism, and stereotactic frames...
10 CFR 35.2645 - Records of periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Records of periodic spot-checks for gamma stereotactic... MATERIAL Records § 35.2645 Records of periodic spot-checks for gamma stereotactic radiosurgery units. (a) A... and intercom systems, timer termination, treatment table retraction mechanism, and stereotactic frames...
10 CFR 35.2645 - Records of periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Records of periodic spot-checks for gamma stereotactic... MATERIAL Records § 35.2645 Records of periodic spot-checks for gamma stereotactic radiosurgery units. (a) A... and intercom systems, timer termination, treatment table retraction mechanism, and stereotactic frames...
Pagella, Fabio; Pusateri, Alessandro; Zaccari, Dario; Bongetta, Daniele; Zoia, Cesare; Spinozzi, Giuseppe; Olivieri, Carla; Matti, Elina
2017-03-01
Hereditary hemorrhagic telangiectasia (HHT) is a rare genetic disease that results in mucocutaneous telangiectasias and arteriovenous visceral malformations. Nasal telangiectasias lead to recurrent epistaxis, which affects up to 96% of patients. Different morphologic classifications and methods of visualization of nasal lesions have been described in the literature. We developed a new method of intraoperative endoscopy based on the intravenous administration of fluorescein. Preliminary data of this technique are reported. After the intravenous administration of sodium fluorescein, an intraoperative fluorescein-guided endoscopy was carried out using photographic customized yellow filters on top of a 0-degree, 4-mm endoscope. In 2015, 65 HHT patients underwent surgery for their epistaxis in our institution, and in 7 patients (3 males, 4 females; mean age, 54 years) an intraoperative fluorescein-guided intraoperative nasal endoscopy was performed. No adverse events or complications were observed. First impressions regarding the usage of this technique in HHT patients seem to be promising and positive in terms of efficacy and safety. However, further studies with larger cohorts of patients should be performed in order to better investigate the use of this method for diagnostic and surgical purposes in HHT. © 2016 ARS-AAOA, LLC.
Bahrami, Soheyl; Zimmermann, Klaus; Szelényi, Zoltán; Hamar, János; Scheiflinger, Friedrich; Redl, Heinz; Junger, Wolfgang G
2006-03-01
Hemorrhage remains a primary cause of death in civilian and military trauma. Permissive hypotensive resuscitation is a possible approach to reduce bleeding in patients until they can be stabilized in an appropriate hospital setting. Small-volume resuscitation with hypertonic saline (HS) is of particular interest because it allows one to modulate the inflammatory response to hemorrhage and trauma. Here, we tested the utility of permissive hypotensive resuscitation with hypertonic fluids in a rat model of hemorrhagic shock. Animals were subjected to massive hemorrhage [mean arterial pressure (MAP) = 30 - 35 mmHg for 2 h until decompensation] and partially resuscitated with a bolus dose of 4 mL/kg of 7.5% NaCl (HS), hypertonic hydroxyl ethyl starch (HHES; hydroxyl ethyl starch + 7.5% NaCl), or normal saline (NS) followed by additional infusion of Ringer solution to maintain MAP at 40 to 45 mmHg for 40 min (hypotensive state). Finally, animals were fully resuscitated with Ringer solution and the heparinized shed blood. Hypotensive resuscitation with NS caused a significant increase in plasma interleukin (IL)-1beta, IL-6, IL-2, interferon gamma (IFNgamma), IL-10, and granulocyte-macrophage colony stimulating factor (GM-CSF). This increase was blocked by treatment with HS. HHES treatment significantly reduced the increase of IL-1beta and IL-2 but not that of the other cytokines studied. Despite the strong effects of HS and HHES on cytokine production, both treatments had little effect on plasma lactate, base excess (BE), white blood cell (WBC) count, myeloperoxidase (MPO) content, and the wet/dry weight ratio of the lungs. Moreover, on day 7 after shock, the survival rate in rats treated with HS was markedly, but not significantly, lower than that of NS-treated animals (47% vs. 63%, respectively). In summary, hypotensive resuscitation with hypertonic fluids reduces the inflammatory response but not lung tissue damage or mortality after severe hemorrhagic shock.
Plasma 8-iso-Prostaglandin F2α concentrations and outcomes after acute intracerebral hemorrhage.
Du, Quan; Yu, Wen-Hua; Dong, Xiao-Qiao; Yang, Ding-Bo; Shen, Yong-Feng; Wang, Hao; Jiang, Li; Du, Yuan-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie
2014-11-01
Higher plasma 8-iso-Prostaglandin F2α concentrations have been associated with poor outcome of severe traumatic brain injury. We further investigated the relationships between plasma 8-iso-Prostaglandin F2α concentrations and clinical outcomes in patients with acute intracerebral hemorrhage. Plasma 8-iso-Prostaglandin F2α concentrations of 128 consecutive patients and 128 sex- and gender-matched healthy subjects were measured by enzyme-linked immunosorbent assay. We assessed their relationships with disease severity and clinical outcomes including 1-week mortality, 6-month mortality and unfavorable outcome (modified Rankin Scale score>2). Plasma 8-iso-Prostaglandin F2α concentrations were substantially higher in patients than in healthy controls. Plasma 8-iso-Prostaglandin F2α concentrations were positively associated with National Institutes of Health Stroke Scale (NIHSS) scores and hematoma volume using a multivariate linear regression. It emerged as an independent predictor for clinical outcomes of patients using a forward stepwise logistic regression. ROC curves identified the predictive values of plasma 8-iso-Prostaglandin F2α concentrations, and found its predictive value was similar to NIHSS scores and hematoma volumes. However, it just numerically added the predictive values of NIHSS score and hematoma volume. Increased plasma 8-iso-Prostaglandin F2α concentrations are associated with disease severity and clinical outcome after acute intracerebral hemorrhage. Copyright © 2014 Elsevier B.V. All rights reserved.
Stern, S A; Jwayyed, S; Dronen, S C; Wang, X
2000-08-01
Resuscitation studies of hypertonic saline using controlled and uncontrolled hemorrhage models yield conflicting results with regard to efficacy. These disparate results reflect the use of models and resuscitation regimens that are not comparable between studies. This study evaluated the effects of comparable and clinically relevant resuscitation regimens of 7.5% sodium chloride/6% dextran 70 (HSD) and 0.9% sodium chloride (NS) in a near-fatal uncontrolled hemorrhage model. Thirty-six swine (14.2 to 21.4 kg) with 4-mm aortic tears were bled to a pulse pressure of 5 mm Hg (40-45 mL/kg). The animals were resuscitated with either NS or HSD administered in volumes that provided equivalent sodium loads at similar rates. Group II (n = 12) was resuscitated with 80 mL/kg of NS at a rate of 4 mL/kg/min. Group III (n = 12) received 9.6 mL/kg of HSD at a rate of 0.48 mL/kg/min. In both groups, crystalloid resuscitation was followed by shed blood infusion (30 mL/kg) at a rate of 2 mL/kg/min. Group I (controls; n = 12) were not resuscitated. One-hour mortality was significantly greater in group I (92%) as compared with group II (33%) and group III (33%) (Fisher's exact test; p = 0.004). Intraperitoneal hemorrhage was significantly greater in group II (34 +/- 20 mL/kg) and group III (31 +/- 13 mL/ kg) as compared with group I (5 +/- 2 mL/kg) (ANOVA; p < 0.05). There was no significant difference in hemodynamic parameters between groups II and III. In this model of severe uncontrolled hemorrhage, resuscitation with HSD or NS, administered in volumes that provided equivalent sodium loads at similar rates, had similar effects on mortality, hemodynamic parameters, and hemorrhage from the injury site.
Variations in the intensive use of head CT for elderly patients with hemorrhagic stroke.
Bekelis, Kimon; Fisher, Elliott S; Labropoulos, Nicos; Zhou, Weiping; Skinner, Jonathan
2015-04-01
To investigate the variability in head computed tomographic (CT) scanning in patients with hemorrhagic stroke in U.S. hospitals, its association with mortality, and the number of different physicians consulted. The study was approved by the Committee for the Protection of Human Subjects at Dartmouth College. A retrospective analysis of the Medicare fee-for-service claims data was performed for elderly patients admitted for hemorrhagic stroke in 2008-2009, with 1-year follow-up through 2010. Risk-adjusted primary outcome measures were mean number of head CT scans performed and high-intensity use of head CT (six or more head CT scans performed in the year after admission). We examined the association of high-intensity use of head CT with the number of different physicians consulted and mortality. A total of 53 272 patients (mean age, 79.6 years; 31 377 women [58.9%]) with hemorrhagic stroke were identified in the study period. The mean number of head CT scans conducted in the year after admission for stroke was 3.4; 8737 patients (16.4%) underwent six or more scans. Among the hospitals with the highest case volume (more than 50 patients with hemorrhagic stroke), risk-adjusted rates ranged from 8.0% to 48.1%. The correlation coefficient between number of physicians consulted and rates of high-intensity use of head CT was 0.522 (P < .01) for all hospitals and 0.50 (P < .01) for the highest-volume hospitals. No improvement in 1-year mortality was found for patients undergoing six or more head CT scans (odds ratio, 0.84; 95% confidence interval: 0.69, 1.02). High rates of head CT use for patients with hemorrhagic stroke are frequently observed, without an association with decreased mortality. A higher number of physicians consulted was associated with high-intensity use of head CT. © RSNA, 2014 Online supplemental material is available for this article.
Tranexamic Acid for Lower GI Hemorrhage: A Randomized Placebo-Controlled Clinical Trial.
Smith, Stephen R; Murray, David; Pockney, Peter G; Bendinelli, Cino; Draganic, Brian D; Carroll, Rosemary
2018-01-01
Lower GI hemorrhage is a common source of morbidity and mortality. Tranexamic acid is an antifibrinolytic that has been shown to reduce blood loss in a variety of clinical conditions. Information regarding the use of tranexamic acid in treating lower GI hemorrhage is lacking. The aim of this trial was to determine the clinical efficacy of tranexamic acid when used for lower GI hemorrhage. This was a prospective, double-blind, placebo-controlled, randomized clinical trial. The study was conducted at a tertiary referral university hospital in Australia. Consecutive patients aged >18 years with lower GI hemorrhage requiring hospital admission from November 2011 to January 2014 were screened for trial eligibility (N = 265). A total of 100 patients were recruited after exclusions and were randomly assigned 1:1 to either tranexamic acid or placebo. The primary outcome was blood loss as determined by reduction in hemoglobin levels. The secondary outcomes were transfusion rates, transfusion volume, intervention rates for bleeding, length of hospital stay, readmission, and complication rates. There was no difference between groups with respect to hemoglobin drop (11 g/L of tranexamic acid vs 13 g/L of placebo; p = 0.9445). There was no difference with respect to transfusion rates (14/49 tranexamic acid vs 16/47 placebo; p = 0.661), mean transfusion volume (1.27 vs 1.93 units; p = 0.355), intervention rates (7/49 vs 13/47; p = 0.134), length of hospital stay (4.67 vs 4.74 d; p = 0.934), readmission, or complication rates. No complications occurred as a direct result of tranexamic acid use. A larger multicenter trial may be required to determine whether there are more subtle advantages with tranexamic acid use in some of the secondary outcomes. Tranexamic acid does not appear to decrease blood loss or improve clinical outcomes in patients presenting with lower GI hemorrhage in the context of this trial. see Video Abstract at http://links.lww.com/DCR/A453.
Laurent, Alexis; Dokmak, Safi; Nault, Jean-Charles; Pruvot, François-René; Fabre, Jean-Michel; Letoublon, Christian; Bachellier, Philippe; Capussotti, Lorenzo; Farges, Olivier; Mabrut, Jean-Yves; Le Treut, Yves-Patrice; Ayav, Ahmet; Suc, Bertrand; Soubrane, Olivier; Mentha, Gilles; Popescu, Irinel; Montorsi, Marco; Demartines, Nicolas; Belghiti, Jacques; Torzilli, Guido; Cherqui, Daniel; Hardwigsen, Jean
2016-09-01
Hepatocellular adenoma (HCA) is a benign hepatic lesion that may be complicated by bleeding and malignant transformation. The aim of the present study is to report on large series of liver resections for HCA and assess the incidence of hemorrhage and malignant transformation. A retrospective cross-sectional study, from 27 European high-volume HPB units. 573 patients were analyzed. The female: male gender ratio was 8:2, mean age: 37 ± 10 years. Of the 84 (14%) patients whose initial presentation was hemorrhagic shock (Hemorrhagic HCAs), hemostatic intervention was urgently required in 25 (30%) patients. No patients died after intervention. Tumor size was >5 cm in 74% in hemorrhagic HCAs and 64% in non-hemorrhagic HCAs (p < 0.001). In non-hemorrhagic HCAs (n = 489), 5% presented with malignant transformation. Male status and tumor size >10 cm were the two predictive factors. Liver resections included major hepatectomy in 25% and a laparoscopic approach in 37% of the patients. In non-hemorrhagic HCAs, there was no mortality and major complications occurred in 9% of patients. Liver resection for HCA is safe. Presentation with hemorrhage was associated with larger tumor size. In males with a HCA >10 cm, a HCC should be suspected. In such situation, a preoperative biopsy is preferable and an oncological liver resection should be considered. Copyright © 2016 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.
Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage
NASA Astrophysics Data System (ADS)
Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.
2014-03-01
Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.
Intensive Blood-Pressure Lowering in Patients with Acute Cerebral Hemorrhage.
Qureshi, Adnan I; Palesch, Yuko Y; Barsan, William G; Hanley, Daniel F; Hsu, Chung Y; Martin, Renee L; Moy, Claudia S; Silbergleit, Robert; Steiner, Thorsten; Suarez, Jose I; Toyoda, Kazunori; Wang, Yongjun; Yamamoto, Haruko; Yoon, Byung-Woo
2016-09-15
Limited data are available to guide the choice of a target for the systolic blood-pressure level when treating acute hypertensive response in patients with intracerebral hemorrhage. We randomly assigned eligible participants with intracerebral hemorrhage (volume, <60 cm(3)) and a Glasgow Coma Scale (GCS) score of 5 or more (on a scale from 3 to 15, with lower scores indicating worse condition) to a systolic blood-pressure target of 110 to 139 mm Hg (intensive treatment) or a target of 140 to 179 mm Hg (standard treatment) in order to test the superiority of intensive reduction of systolic blood pressure to standard reduction; intravenous nicardipine to lower blood pressure was administered within 4.5 hours after symptom onset. The primary outcome was death or disability (modified Rankin scale score of 4 to 6, on a scale ranging from 0 [no symptoms] to 6 [death]) at 3 months after randomization, as ascertained by an investigator who was unaware of the treatment assignments. Among 1000 participants with a mean (±SD) systolic blood pressure of 200.6±27.0 mm Hg at baseline, 500 were assigned to intensive treatment and 500 to standard treatment. The mean age of the patients was 61.9 years, and 56.2% were Asian. Enrollment was stopped because of futility after a prespecified interim analysis. The primary outcome of death or disability was observed in 38.7% of the participants (186 of 481) in the intensive-treatment group and in 37.7% (181 of 480) in the standard-treatment group (relative risk, 1.04; 95% confidence interval, 0.85 to 1.27; analysis was adjusted for age, initial GCS score, and presence or absence of intraventricular hemorrhage). Serious adverse events occurring within 72 hours after randomization that were considered by the site investigator to be related to treatment were reported in 1.6% of the patients in the intensive-treatment group and in 1.2% of those in the standard-treatment group. The rate of renal adverse events within 7 days after randomization was significantly higher in the intensive-treatment group than in the standard-treatment group (9.0% vs. 4.0%, P=0.002). The treatment of participants with intracerebral hemorrhage to achieve a target systolic blood pressure of 110 to 139 mm Hg did not result in a lower rate of death or disability than standard reduction to a target of 140 to 179 mm Hg. (Funded by the National Institute of Neurological Disorders and Stroke and the National Cerebral and Cardiovascular Center; ATACH-2 ClinicalTrials.gov number, NCT01176565 .).
Sidhu, Deepinder S; Ruth, Jeffrey D; Lambert, Gregory; Rossmeisl, John H
2017-07-01
To develop and validate a three-dimensional (3D) brain phantom that can be incorporated into existing stereotactic headframes to simulate stereotactic brain biopsy (SBB) and train veterinary surgeons. Experimental study. Canine brain phantoms were fabricated from osteological skull specimens, agarose brain parenchyma, and cheddar and mozzarella cheese molds (simulating meningiomas and gliomas). The neuroradiologic and viscoelastic properties of phantoms were quantified with computed tomography (CT) and oscillatory compression tests, respectively. Phantoms were validated by experienced and novice operators performing SBB on phantoms containing randomly placed, focal targets. Target yield and needle placement error (NPE) were compared between operators. Phantoms were produced in <4 hours, at an average cost of $92. The CT appearances of the phantom skull, agarose, and cheese components approximated the in vivo features of skull, brain parenchyma, and contrast-enhancing tumors of meningeal and glial origin, respectively. The complex moduli of the agarose and cheeses were comparable to the viscoelastic properties of in vivo brain tissues and brain tumors. The overall diagnostic yield of SBB was 88%. Although NPE did not differ between novice (median 3.68 mm; range, 1.46-14.54 mm) and experienced surgeons (median 1.17 mm, range, 0.78-1.58 mm), our results support the relevance of the learning curve associated with the SBB procedure. This 3D phantom replicates anatomical, CT, and tactile features of brain tissues and tumors and can be used to develop the technical skills required to perform SBB. © 2017 The American College of Veterinary Surgeons.
Robot-assisted procedures in pediatric neurosurgery.
De Benedictis, Alessandro; Trezza, Andrea; Carai, Andrea; Genovese, Elisabetta; Procaccini, Emidio; Messina, Raffaella; Randi, Franco; Cossu, Silvia; Esposito, Giacomo; Palma, Paolo; Amante, Paolina; Rizzi, Michele; Marras, Carlo Efisio
2017-05-01
OBJECTIVE During the last 3 decades, robotic technology has rapidly spread across several surgical fields due to the continuous evolution of its versatility, stability, dexterity, and haptic properties. Neurosurgery pioneered the development of robotics, with the aim of improving the quality of several procedures requiring a high degree of accuracy and safety. Moreover, robot-guided approaches are of special interest in pediatric patients, who often have altered anatomy and challenging relationships between the diseased and eloquent structures. Nevertheless, the use of robots has been rarely reported in children. In this work, the authors describe their experience using the ROSA device (Robotized Stereotactic Assistant) in the neurosurgical management of a pediatric population. METHODS Between 2011 and 2016, 116 children underwent ROSA-assisted procedures for a variety of diseases (epilepsy, brain tumors, intra- or extraventricular and tumor cysts, obstructive hydrocephalus, and movement and behavioral disorders). Each patient received accurate preoperative planning of optimal trajectories, intraoperative frameless registration, surgical treatment using specific instruments held by the robotic arm, and postoperative CT or MR imaging. RESULTS The authors performed 128 consecutive surgeries, including implantation of 386 electrodes for stereo-electroencephalography (36 procedures), neuroendoscopy (42 procedures), stereotactic biopsy (26 procedures), pallidotomy (12 procedures), shunt placement (6 procedures), deep brain stimulation procedures (3 procedures), and stereotactic cyst aspiration (3 procedures). For each procedure, the authors analyzed and discussed accuracy, timing, and complications. CONCLUSIONS To the best their knowledge, the authors present the largest reported series of pediatric neurosurgical cases assisted by robotic support. The ROSA system provided improved safety and feasibility of minimally invasive approaches, thus optimizing the surgical result, while minimizing postoperative morbidity.
Re: Coagulation and Fluid Resuscitation by HyperHES in Severe Hemorrhage
2013-08-01
aid kit, and we cannot envisage to load them with so much weight. In the context of trauma combat casualty care, fluid resuscitation byHyperHES...coagulation following femur injury and severe hemorrhage in pigs. J Trauma Acute Care Surg. 2013; 74(3):732Y740. 2. Dubick MA, Atkins JL. Small-volume...fluid resuscitation for the far-forward combat envi- ronment: current concepts. J Trauma . 2003;54: S43YS45. 3. Sharma P, Benford B, Karaian JE
Portable Low-Volume Therapy for Severe Blood Loss
2015-06-01
A blood transfusion restored tHb levels in close to baseline in hypovolemic animals. sO2 at T0 was slightly decreased in all groups, probably as a...result of anesthesia as isoflurane has been known to cause dips in sO2 at concentrations larger than 2% (17). pO2 was higher in all hemorrhaged...animals survived to 10 days since they were not hemorrhaged and including them in this analyses could misrepresent the data. At T0, sO2 was higher
Method and devices for performing stereotactic microbeam radiation therapy
Dilmanian, F. Avraham
2010-01-05
A radiation delivery system generally includes either a synchrotron source or a support frame and a plurality of microbeam delivery devices supported on the support frame, both to deliver a beam in a hemispherical arrangement. Each of the microbeam delivery devices or synchrotron irradiation ports is adapted to deliver at least one microbeam of radiation along a microbeam delivery axis, wherein the microbeam delivery axes of the plurality of microbeam delivery devices cross within a common target volume.
Pulmonary Function Testing After Stereotactic Body Radiotherapy to the Lung
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bishawi, Muath; Kim, Bong; Moore, William H.
2012-01-01
Purpose: Surgical resection remains the standard of care for operable early-stage non-small-cell lung cancer (NSCLC). However, some patients are not fit for surgery because of comorbidites such as chronic obstructive pulmonary disease (COPD) and other medical conditions. We aimed to evaluate pulmonary function and tumor volume before and after stereotactic body radiotherapy (SBRT) for patients with and without COPD in early-stage lung cancer. Methods and Materials: A review of prospectively collected data of Stage I and II lung cancers, all treated with SBRT, was performed. The total SBRT treatment was 60 Gy administered in three 20 Gy fractions. The patientsmore » were analyzed based on their COPD status, using their pretreatment pulmonary function test cutoffs as established by the American Thoracic Society guidelines (forced expiratory volume [FEV]% {<=}50% predicted, FEV%/forced vital capacity [FVC]% {<=}70%). Changes in tumor volume were also assessed by computed tomography. Results: Of a total of 30 patients with Stage I and II lung cancer, there were 7 patients in the COPD group (4 men, 3 women), and 23 in t he No-COPD group (9 men, 14 women). At a mean follow-up time of 4 months, for the COPD and No-COPD patients, pretreatment and posttreatment FEV% was similar: 39 {+-} 5 vs. 40 {+-} 9 (p = 0.4) and 77 {+-} 0.5 vs. 73 {+-} 24 (p = 0.9), respectively. The diffusing capacity of the lungs for carbon monoxide (DL{sub CO}) did significantly increase for the No-COPD group after SBRT treatment: 60 {+-} 24 vs. 69 {+-} 22 (p = 0.022); however, DL{sub CO} was unchanged for the COPD group: 49 {+-} 13 vs. 50 {+-} 14 (p = 0.8). Although pretreatment tumor volume was comparable for both groups, tumor volume significantly shrank in the No-COPD group from 19 {+-} 24 to 9 {+-} 16 (p < 0.001), and there was a trend in the COPD patients from 12 {+-} 9 to 6 {+-} 5 (p = 0.06). Conclusion: SBRT did not seem to have an effect on FEV{sub 1} and FVC, but it shrank tumor volume and improved DL{sub CO} for patients without COPD.« less
Mutter, Robert W; Liu, Fan; Abreu, Andres; Yorke, Ellen; Jackson, Andrew; Rosenzweig, Kenneth E
2012-04-01
Chest wall (CW) pain has recently been recognized as an important adverse effect of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC). We developed a dose-volume model to predict the development of this toxicity. A total of 126 patients with primary, clinically node-negative NSCLC received three to five fractions of SBRT to doses of 40-60 Gy and were prospectively followed. The dose-absolute volume histograms of two different definitions of the CW as an organ at risk (CW3cm and CW2cm) were examined for all 126 patients. With a median follow-up of 16 months, the 2-year estimated actuarial incidence of Grade ≥ 2 CW pain was 39%. The median time to onset of Grade ≥ 2 CW pain (National Cancer Institute Common Terminology Criteria for Adverse Events, Version 3.0) was 9 months. There was no predictive advantage for biologically corrected dose over physical dose. Neither fraction number (p = 0.07) nor prescription dose (p = 0.07) were significantly correlated with the development of Grade ≥ 2 CW pain. Cox Proportional Hazards analysis identified significant correlation with a broad range of dose-volume combinations, with the CW volume receiving 30 Gy (V30) as one of the strongest predictors (p < 0.001). CW2cm consistently enabled better prediction of CW toxicity. When a physical dose of 30 Gy was received by more than 70 cm(3) of CW2cm, there was a significant correlation with Grade ≥ 2 CW pain (p = 0.004). CW toxicity after SBRT is common and long-term follow-up is needed to identify affected patients. A volume of CW ≥ 70 cm(3) receiving 30 Gy is significantly correlated with Grade ≥ 2 CW pain. We are currently applying this constraint at our institution for patients receiving thoracic SBRT. An actuarial atlas of our data is provided as an electronic supplement to facilitate data-sharing and meta-analysis relating to CW pain. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldstein, Jeffrey D.; Lawrence, Yaacov R.; Sackler School of Medicine, Tel Aviv University, Tel Aviv
Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test.more » CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.« less
Simultaneous integrated protection : A new concept for high-precision radiation therapy.
Brunner, Thomas B; Nestle, Ursula; Adebahr, Sonja; Gkika, Eleni; Wiehle, Rolf; Baltas, Dimos; Grosu, Anca-Ligia
2016-12-01
Stereotactic radiotherapy near serial organs at risk (OAR) requires special caution. A novel intensity-modulated radiotherapy (IMRT) prescription concept termed simultaneous integrated protection (SIP) for quantifiable and comparable dose prescription to targets very close to OAR is described. An intersection volume of a planning risk volume (PRV) with the total planning target volume (PTV) defined the protection volume (PTV SIP ). The remainder of the PTV represented the dominant PTV (PTV dom ). Planning was performed using IMRT. Dose was prescribed to PTV dom according to ICRU in 3, 5, 8, or 12 fractions. Constraints to OARs were expressed as absolute and as equieffective doses at 2 Gy (EQD2). Dose to the gross risk volume of an OAR was to respect constraints. Violation of constraints to OAR triggered a planning iteration at increased fractionation. Dose to PTV SIP was required to be as high as possible within the constraints to avoid local relapse. SIP was applied in 6 patients with OAR being large airways (n = 2) or bowel (n = 4) in 3, 5, 8, and 12 fractions in 1, 3, 1, and 1 patients, respectively. PTVs were 14.5-84.9 ml and PTV SIP 1.8-3.9 ml (2.9-13.4 % of PTV). Safety of the plans was analyzed from the absolute dose-volume histogram (dose to ml). The steepness of dose fall-off could be determined by comparing the dose constraints to the PRVs with those to the OARs (Wilcoxon test p = 0.001). Constraints were respected for the corresponding OARs. All patients had local control at a median 9 month follow-up and toxicity was low. SIP results in a median dose of ≥100 % to PTV, to achieve high local control and low toxicity. Longer follow-up is required to verify results and a prospective clinical trial is currently testing this new approach in chest and abdomen stereotactic body radiotherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mutter, Robert W.; Liu Fan; Abreu, Andres
Purpose: Chest wall (CW) pain has recently been recognized as an important adverse effect of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC). We developed a dose-volume model to predict the development of this toxicity. Methods and Materials: A total of 126 patients with primary, clinically node-negative NSCLC received three to five fractions of SBRT to doses of 40-60 Gy and were prospectively followed. The dose-absolute volume histograms of two different definitions of the CW as an organ at risk (CW3cm and CW2cm) were examined for all 126 patients. Results: With a median follow-up of 16 months, themore » 2-year estimated actuarial incidence of Grade {>=} 2 CW pain was 39%. The median time to onset of Grade {>=} 2 CW pain (National Cancer Institute Common Terminology Criteria for Adverse Events, Version 3.0) was 9 months. There was no predictive advantage for biologically corrected dose over physical dose. Neither fraction number (p = 0.07) nor prescription dose (p = 0.07) were significantly correlated with the development of Grade {>=} 2 CW pain. Cox Proportional Hazards analysis identified significant correlation with a broad range of dose-volume combinations, with the CW volume receiving 30 Gy (V30) as one of the strongest predictors (p < 0.001). CW2cm consistently enabled better prediction of CW toxicity. When a physical dose of 30 Gy was received by more than 70 cm{sup 3} of CW2cm, there was a significant correlation with Grade {>=} 2 CW pain (p = 0.004). Conclusions: CW toxicity after SBRT is common and long-term follow-up is needed to identify affected patients. A volume of CW {>=} 70 cm{sup 3} receiving 30 Gy is significantly correlated with Grade {>=} 2 CW pain. We are currently applying this constraint at our institution for patients receiving thoracic SBRT. An actuarial atlas of our data is provided as an electronic supplement to facilitate data-sharing and meta-analysis relating to CW pain.« less
Huang, Bao-Tian; Lin, Zhu; Lin, Pei-Xian; Lu, Jia-Yang; Chen, Chuang-Zhen
2016-06-28
This study aims to compare the radiobiological response of two stereotactic body radiotherapy (SBRT) schedules for patients with stage I peripheral non-small cell lung cancer (NSCLC) using radiobiological modeling methods. Volumetric modulated arc therapy (VMAT)-based SBRT plans were designed using two dose schedules of 1 × 34 Gy (34 Gy in 1 fraction) and 4 × 12 Gy (48 Gy in 4 fractions) for 19 patients diagnosed with primary stage I NSCLC. Dose to the gross target volume (GTV), planning target volume (PTV), lung and chest wall (CW) were converted to biologically equivalent dose in 2 Gy fraction (EQD2) for comparison. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three additional models were utilized to estimate the normal tissue complication probability (NTCP) value for the lung and the modified equivalent uniform dose (mEUD) value to the CW. Our result indicates that the 1 × 34 Gy dose schedule provided a higher EQD2 dose to the tumor, lung and CW. Radiobiological modeling revealed that the TCP value for the tumor, NTCP value for the lung and mEUD value for the CW were 7.4% (in absolute value), 7.2% (in absolute value) and 71.8% (in relative value) higher on average, respectively, using the 1 × 34 Gy dose schedule.
Dosimetric benefit of adaptive re-planning in pancreatic cancer stereotactic body radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Yongbao; Center for Advanced Radiotherapy Technologies University of California San Diego, La Jolla, CA; Department of Radiation Oncology, University of California San Diego, La Jolla, CA
Stereotactic body radiotherapy (SBRT) shows promise in unresectable pancreatic cancer, though this treatment modality has high rates of normal tissue toxicity. This study explores the dosimetric utility of daily adaptive re-planning with pancreas SBRT. We used a previously developed supercomputing online re-planning environment (SCORE) to re-plan 10 patients with pancreas SBRT. Tumor and normal tissue contours were deformed from treatment planning computed tomographies (CTs) and transferred to daily cone-beam CT (CBCT) scans before re-optimizing each daily treatment plan. We compared the intended radiation dose, the actual radiation dose, and the optimized radiation dose for the pancreas tumor planning target volumemore » (PTV) and the duodenum. Treatment re-optimization improved coverage of the PTV and reduced dose to the duodenum. Within the PTV, the actual hot spot (volume receiving 110% of the prescription dose) decreased from 4.5% to 0.5% after daily adaptive re-planning. Within the duodenum, the volume receiving the prescription dose decreased from 0.9% to 0.3% after re-planning. It is noteworthy that variation in the amount of air within a patient's stomach substantially changed dose to the PTV. Adaptive re-planning with pancreas SBRT has the ability to improve dose to the tumor and decrease dose to the nearby duodenum, thereby reducing the risk of toxicity.« less
Yorke, Ellen; Xiong, Ying; Han, Qian; Zhang, Pengpeng; Mageras, Gikas; Lovelock, Michael; Pham, Hai; Xiong, Jian-Ping; Goodman, Karyn A
2016-07-01
To assess intrafraction respiratory motion using a commercial kilovoltage imaging system for abdominal tumor patients with implanted fiducials and breathing constrained by pneumatic compression during stereotactic body radiation therapy (SBRT). A pneumatic compression belt limited respiratory motion in 19 patients with radiopaque fiducials in or near their tumor during SBRT for abdominal tumors. Kilovoltage images were acquired at 5- to 6-second intervals during treatment using a commercial system. Intrafractional fiducial displacements were measured using in-house software. The dosimetric effect of the observed displacements was calculated for 3 sessions for each patient. Intrafraction displacement patterns varied between patients and between individual treatment sessions. Averaged over 19 patients, 73 sessions, 7.6% of craniocaudal displacements exceeded 0.5 cm, and 1.2% exceeded 0.75 cm. The calculated single-session dose to 95% of gross tumor volume differed from planned by an average of -1.2% (range, -11.1% to 4.8%) but only for 4 patients was the total 3-session calculated dose to 95% of gross tumor volume more than 3% different from planned. Our pneumatic compression limited intrafractional abdominal target motion, maintained target position established at setup, and was moderately effective in preserving coverage. Commercially available intrafractional imaging is useful for surveillance but can be made more effective and reliable. Copyright © 2015 Elsevier Inc. All rights reserved.
Synthetic CT for MRI-based liver stereotactic body radiotherapy treatment planning
NASA Astrophysics Data System (ADS)
Bredfeldt, Jeremy S.; Liu, Lianli; Feng, Mary; Cao, Yue; Balter, James M.
2017-04-01
A technique for generating MRI-derived synthetic CT volumes (MRCTs) is demonstrated in support of adaptive liver stereotactic body radiation therapy (SBRT). Under IRB approval, 16 subjects with hepatocellular carcinoma were scanned using a single MR pulse sequence (T1 Dixon). Air-containing voxels were identified by intensity thresholding on T1-weighted, water and fat images. The envelope of the anterior vertebral bodies was segmented from the fat image and fuzzy-C-means (FCM) was used to classify each non-air voxel as mid-density, lower-density, bone, or marrow in the abdomen, with only bone and marrow classified within the vertebral body envelope. MRCT volumes were created by integrating the product of the FCM class probability with its assigned class density for each voxel. MRCTs were deformably aligned with corresponding planning CTs and 2-ARC-SBRT-VMAT plans were optimized on MRCTs. Fluence was copied onto the CT density grids, dose recalculated, and compared. The liver, vertebral bodies, kidneys, spleen and cord had median Hounsfield unit differences of less than 60. Median target dose metrics were all within 0.1 Gy with maximum differences less than 0.5 Gy. OAR dose differences were similarly small (median: 0.03 Gy, std:0.26 Gy). Results demonstrate that MRCTs derived from a single abdominal imaging sequence are promising for use in SBRT dose calculation.
Saeed, Maythem; Krug, Roland; Do, Loi; Hetts, Steven W; Wilson, Mark W
2016-03-28
To use magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU), magnetic resonance imaging (MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. Six anesthetized/mechanically-ventilated pigs underwent single/double renal sonication (n = 24) using a 3T-MRg-HIFU (1.1 MHz frequency and 3000J-4400J energies). T2-weighted fast spin echo (T2-W), perfusion saturation recovery gradient echo and contrast enhanced (CE) T1-weighted (T1-W) sequences were used for treatment planning, temperature monitoring, lesion visualization, characterization and quantification, respectively. Histopathology was conducted in excised kidneys to quantify and characterize cellular and vascular changes. Paired Student's t-test was used and a P-value < 0.05 was considered statistically significant. Ablated renal parenchyma could not be differentiated from normal parenchyma on T2-W or non-CE T1-W sequences. Ablated renal lesions were visible as hypoenhanced regions on perfusion and CE T1-W MRI sequences, suggesting perfusion deficits and necrosis. Volumes of ablated parenchyma on CE T1-W images in vivo (0.12-0.36 cm(3) for single sonication 3000J, 0.50-0.84 cm(3), for double 3000J, 0.75-0.78 cm(3) for single 4400J and 0.12-2.65 cm(3) for double 4400J) and at postmortem (0.23-0.52 cm(3), 0.25-0.82 cm(3), 0.45-0.68 cm(3) and 0.29-1.80 cm(3), respectively) were comparable. The ablated volumes on 3000J and 4400J double sonication were significantly larger than single (P < 0.01), thus, the volume and depth of ablated tissue depends on the applied energy and number of sonication. Macroscopic and microscopic examinations confirmed the locations and presence of coagulation necrosis, vascular damage and interstitial hemorrhage, respectively. Contrast enhanced MRI provides assessment of MRg-HIFU renal ablation. Histopathology demonstrated coagulation necrosis, vascular damage and confirmed the volume of damage seen on MRI.
Lovelock, D Michael; Messineo, Alessandra P; Cox, Brett W; Kollmeier, Marisa A; Zelefsky, Michael J
2015-03-01
To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lovelock, D. Michael, E-mail: lovelocm@mskcc.org; Messineo, Alessandra P.; Cox, Brett W.
2015-03-01
Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting themore » couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.« less
Cohen, José E; Gomori, John M; Benifla, Moni; Itshayek, Eyal; Moscovici, Samuel
2013-01-01
A 4-month-old female presented with a dural arteriovenous fistula (DAVF), which was successfully managed using endovascular techniques. There are very few case series reporting DAVF in infants younger than 12 months and, to our knowledge, only 60 pediatric patients with DAVF have been reported to date. Although most DAVF have a benign course, they can result in life-threatening hemorrhage. Endovascular therapies are usually indicated in the management of these neurosurgical vascular malformations. Endovascular therapy of DAVF in neonatal patients presents some major issues. Gaining arterial access may be problematic in femoral arteries too small for the introduction of a sizeable guiding catheter. The volumes of contrast and infused fluids must be carefully monitored to prevent fluid overload. Radiation exposure should be restricted as far as possible. This report contributes to the limited body of evidence on neonatal DAVF and its endovascular management. Copyright © 2012 Elsevier Ltd. All rights reserved.
Conservative management of neonatal cerebral sinovenous thrombosis with coexisting thrombophilia.
Khatri, Vidushi; Chan, Anthony K C; Stein, Nina; Paes, Bosco; Bhatt, Mihir
2018-06-01
: Neonatal cerebral sinovenous thrombosis (CSVT) comprises approximately 50% of all pediatric-related CSVT. Although guidelines support anticoagulation in pediatric CSVT, the role of anticoagulation in neonatal CSVT remains controversial. This case report details the course of a neonate diagnosed with extensive CSVT and concurrent bilateral thalamic and intraventricular hemorrhage. Due to existing hemorrhage at the time of diagnosis, anticoagulation therapy was not administered. Despite coexisting protein C and antithrombin deficiency, CSVT resolved spontaneously, and neurodevelopmental follow-up after 13 years suggests a good prognosis. Although our case had a positive outcome, the association between the use of anticoagulation with concurrent hemorrhage and long-term outcome in neonatal CSVT has not been investigated in prospective studies to firmly guide optimum treatment. Current literature and guidelines for the treatment of neonatal CSVT are reviewed in this article. Until robust studies are available, expert opinion recommends anticoagulation in a stable neonate with CSVT.
Wellmer, Jörg; Parpaley, Yaroslav; Rampp, Stefan; Popkirov, Stoyan; Kugel, Harald; Aydin, Ümit; Wolters, Carsten H; von Lehe, Marec; Voges, Jürgen
2016-03-01
Resective epilepsy surgery is an established treatment option in patients with pharmacoresistant, lesion related epilepsy. Yet, if the presurgical work-up proves multi-focal organization of the epileptogenic zone, or the area of intended resection is close to eloquent brain areas, patients may decide against resections because of an unfavorable risk-benefit-ratio. We assess if lesion guided cortical stereotactic radiofrequency thermocoagulation (L-RFTC) is a potential surgical alternative in these patients. We performed seven procedures of L-RFTC. Three patients had monofocal epilepsy arising close to eloquent structures; in four, invasive pre-surgical workup documented monofocal seizure onset but strong interictal epileptic activity also independent and distant from the seizure onset zone. L-RFTC was restricted to the lesional area (=seizure onset site). 12 to 37 months after RFTC worthwhile seizure improvement was achieved in 6 patients. One patient became seizure free following complete coagulation of a focal cortical dysplasia, two had had 1-2 auras under tapered but not under continued medication. In one patient only subclinical seizures persisted. In one patient hypermotor seizures were transformed into milder short tonic seizures and another one had a seizure reduction by 50%. Only one patient did not profit at all. One patient developed a persisting neurological deficit. In patients with complex epileptogenic zones L-RFTC can lead to worthwhile seizure reduction. This qualifies this procedure as a palliative surgical technique with potential good risk-benefit ratio. In patients with small focal cortical dysplasias L-RFTC may even allow minimal-invasive surgery with curative intention. Copyright © 2016 Elsevier B.V. All rights reserved.
Truse, Richard; Hinterberg, Jonas; Schulz, Jan; Herminghaus, Anna; Weber, Andreas; Mettler-Altmann, Tabea; Bauer, Inge; Picker, Olaf; Vollmer, Christian
2017-01-01
Topical drug application is used to avoid systemic side effects. The aim of this study was to analyze whether locally applied iloprost or nitroglycerin influence gastric mucosal perfusion, oxygenation, and barrier function during physiological and hemorrhagic conditions. In repeated experiments, 5 anesthetized dogs received iloprost, nitroglycerin, or normal saline during physiological and hemorrhagic (-20% blood volume) conditions. Macro- and microcirculatory variables were recorded continuously. Gastric barrier function was assessed via translocation of sucrose into the blood. During hemorrhage, gastric mucosal oxygenation decreased from 77 ± 4 to 37 ± 7%. This effect was attenuated by nitroglycerin (78 ± 6 to 47 ± 13%) and iloprost (82 ± 4 to 54 ± 9%). Sucrose plasma levels increased during hemorrhage from 7 ± 4 to 55 ± 15 relative amounts. This was alleviated by nitroglycerin (5 ± 8 to 29 ± 38 relative amounts). These effects were independent of systemic hemodynamic variables. During hemorrhage, topical nitroglycerin and iloprost improve regional gastric oxygenation without affecting perfusion. Nitroglycerin attenuated the shock-induced impairment of the mucosal barrier integrity. Thus, local drug application improves gastric microcirculation without compromising systemic hemodynamic variables, and it may also protect mucosal barrier function. © 2017 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoogcarspel, S J; Kontaxis, C; Velden, J M van der
2014-06-01
Purpose: To develop an MR accelerator-enabled online planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases. The technical challenges include; automated stereotactic treatment planning, online MR-based dose calculation and MR guidance during treatment. Methods: Using the CT data of 20 patients previously treated at our institution, a class solution for automated treatment planning for spinal bone metastases was created. For accurate dose simulation right before treatment, we fused geometrically correct online MR data with pretreatment CT data of the target volume (TV). For target tracking during treatment, a dynamic T2-weighted TSE MR sequence was developed. An in house developedmore » GPU based IMRT optimization and dose calculation algorithm was used for fast treatment planning and simulation. An automatically generated treatment plan developed with this treatment planning system was irradiated on a clinical 6 MV linear accelerator and evaluated using a Delta4 dosimeter. Results: The automated treatment planning method yielded clinically viable plans for all patients. The MR-CT fusion based dose calculation accuracy was within 2% as compared to calculations performed with original CT data. The dynamic T2-weighted TSE MR Sequence was able to provide an update of the anatomical location of the TV every 10 seconds. Dose calculation and optimization of the automatically generated treatment plans using only one GPU took on average 8 minutes. The Delta4 measurement of the irradiated plan agreed with the dose calculation with a 3%/3mm gamma pass rate of 86.4%. Conclusions: The development of an MR accelerator-enabled planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases was presented. Future work will involve developing an intrafraction motion adaptation strategy, MR-only dose calculation, radiotherapy quality-assurance in a magnetic field, and streamlining the entire treatment process on an MR accelerator.« less
SU-F-T-582: Small Field Dosimetry in Radiosurgery Collimators with a Stealth Chamber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azcona, J; Barbes, B
2016-06-15
Purpose: The extraction of a reference signal for measuring small fields in scanning mode can be problematic. In this work we describe the use of a transmission chamber in small field dosimetry for radiosurgery collimators and compare TMR curves obtained with stereotactic diode and microionization chamber. Methods: Four radiosurgery cones of diameters 5, 10, 12.5, and 15mm supplied by Elekta Medical were commissioned in a 6MV FFF beam from an Elekta Versa linac. A transmission chamber manufactured by IBA (Stealth chamber) was attached to the lower part of the collimators and used for PDD and profile measurements in scanning modemore » with a Scanditronix stereotactic diode. It was also used for centering the stereotactic diode in the water tank to measure TMR and output factors, by integrating the signal. TMR measurements for all collimators and the OF for the largest collimator were also acquired on a polystyrene PTW 29672 phantom with a PTW PinPoint 3D chamber 0.016 cm3 volume. Results: Measured TMR with diode and microionization chamber agreed very well with differences larger than 1% only for depths above 15cm, except the smaller collimator, for which differences were always smaller than 2%. Calculated TMR were significantly different (up to 7%) from measured TMR. The differences are attributed to the change in response of the diode with depth, because the effective field aperture varies with depth. Furthermore, neglecting the ratio of phantom-scatter factors in the conversion formula also contributes to this difference. OF measured with diode and chamber showed a difference of 3.5%. Conclusion: The transmission chamber overcomes the problem of extracting a reference signal and is of great help for small field commissioning. Calculating TMR from PDD is strongly discouraged. Good agreement was found when comparing measurements of TMR with stereotactic diode in water with measurements with microionization chamber in polystyrene.« less
Linskey, M E
2000-12-01
By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image-targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the expense of potential late recurrence. The answer to minimizing complications while maintaining maximum tumor control is improved conformality of radiosurgery dose planning and not resorting to homeopathic radiosurgery doses or hypofractionation radiotherapy schemes.
Linskey, Mark E
2013-12-01
By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image--targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the expense of potential late recurrence. The answer to minimizing complications while maintaining maximum tumor control is improved conformality of radiosurgery dose planning and not resorting to homeopathic radiosurgery doses or hypofractionation radiotherapy schemes.
Targeted Coagulation Management in Severe Trauma: The Controversies and the Evidence.
Winearls, James; Reade, Michael; Miles, Helen; Bulmer, Andrew; Campbell, Don; Görlinger, Klaus; Fraser, John F
2016-10-01
Hemorrhage in the setting of severe trauma is a leading cause of death worldwide. The pathophysiology of hemorrhage and coagulopathy in severe trauma is complex and remains poorly understood. Most clinicians currently treating trauma patients acknowledge the presence of a coagulopathy unique to trauma patients-trauma-induced coagulopathy (TIC)-independently associated with increased mortality. The complexity and incomplete understanding of TIC has resulted in significant controversy regarding optimum management. Although the majority of trauma centers utilize fixed-ratio massive transfusion protocols in severe traumatic hemorrhage, a widely accepted "ideal" transfusion ratio of blood to blood products remains elusive. The recent use of viscoelastic hemostatic assays (VHAs) to guide blood product replacement has further provoked debate as to the optimum transfusion strategy. The use of VHA to quantify the functional contributions of individual components of the coagulation system may permit targeted treatment of TIC but remains controversial and is unlikely to demonstrate a mortality benefit in light of the heterogeneity of the trauma population. Thus, VHA-guided algorithms as an alternative to fixed product ratios in trauma are not universally accepted, and a hybrid strategy starting with fixed-ratio transfusion and incorporating VHA data as they become available is favored by some institutions. We review the current evidence for the management of coagulopathy in trauma, the rationale behind the use of targeted and fixed-ratio approaches and explore future directions.
Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton
2016-01-01
Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003
Continuous blood densitometry - Fluid shifts after graded hemorrhage in animals
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
Rapid fluid shifts in four pigs and two dogs subjected to graded hemorrhage are investigated. Arterial blood density (BD), mean arterial pressure (MAP), central venous pressure (CVP), arterial plasma density (PD), hematocrit (Hct) and erythrocyte density were measured. The apparatus and mechancial oscillator technique for measuring density are described. Fluid shifts between red blood cells and blood plasma and alterations in the whole-body-to-large vessel Hct, F(cell) are studied using two models. The bases of the model calculations are discussed. A decrease in MAP, CVP, and BP is detected at the beginning of hemorrhaging; continued bleeding results in further BD decrease correlating with volume displacement. The data reveal that at 15 ml/kg blood loss the mean PD and BD dropped by 0.99 + or - 0.15 and 2.42 + or 0.26 g/liter, respectively, and the Hct dropped by 2.40 + or 0.47 units. The data reveal that inward-shifted fluid has a higher density than normal ultrafiltrate and/or there is a rise in the F(cell) ratio. It is noted that rapid fluid replacement ranged from 5.8 + or - 0.8 to 10.6 + or - 2.0 percent of the initial plasma volume.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cabrera, Alvin R.; Cuneo, Kyle C.; Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
2013-08-01
Purpose: Virtually all patients with malignant glioma (MG) eventually recur. This study evaluates the safety of concurrent stereotactic radiosurgery (SRS) and bevacizumab (BVZ), an antiangiogenic agent, in treatment of recurrent MG. Methods and Materials: Fifteen patients with recurrent MG, treated at initial diagnosis with surgery and adjuvant radiation therapy/temozolomide and then at least 1 salvage chemotherapy regimen, were enrolled in this prospective trial. Lesions <3 cm in diameter were treated in a single fraction, whereas those 3 to 5 cm in diameter received 5 5-Gy fractions. BVZ was administered immediately before SRS and 2 weeks later. Neurocognitive testing (Mini-Mental Statusmore » Exam, Trail Making Test A/B), Functional Assessment of Cancer Therapy-Brain (FACT-Br) quality-of-life assessment, physical exam, and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) were performed immediately before SRS and 1 week and 2 months following completion of SRS. The primary endpoint was central nervous system (CNS) toxicity. Secondary endpoints included survival, quality of life, microvascular properties as measured by DCE-MRI, steroid usage, and performance status. Results: One grade 3 (severe headache) and 2 grade 2 CNS toxicities were observed. No patients experienced grade 4 to 5 toxicity or intracranial hemorrhage. Neurocognition, quality of life, and Karnofsky performance status did not change significantly with treatment. DCE-MRI results suggest a significant decline in tumor perfusion and permeability 1 week after SRS and further decline by 2 months. Conclusions: Treatment of recurrent MG with concurrent SRS and BVZ was not associated with excessive toxicity in this prospective trial. A randomized trial of concurrent SRS/BVZ versus conventional salvage therapy is needed to establish the efficacy of this approach.« less
Gamma knife radiosurgery for symptomatic brainstem intra-axial cavernous malformations.
Park, Seong-Hyun; Hwang, Sung-Kyoo
2013-12-01
The purpose of this study was to evaluate the efficacy and safety of gamma knife radiosurgery (GKRS) for the treatment of symptomatic brainstem intra-axial cavernous malformations (CMs) associated with high surgical morbidity. Twenty-one patients with symptomatic brainstem intra-axial CMs were treated by GKRS between 2005 and 2010. One patient was lost to follow-up. The median age of the patients was 39.5 years (range, 24-69 years). All patients had experienced 1 or more symptomatic hemorrhages before GKRS (range, 1-3). The median marginal radiation dose was 13 Gy, and the median volume of the malformation was 0.56 mL. The median follow-up period after radiosurgery was 32 months (range, 12-82 months; mean, 38.9 months). Before GKRS, 31 hemorrhages (1.55 per patient) were observed. The annual hemorrhage rate before GKRS was 39.5%, excluding the first hemorrhage. After GKRS, 1 hemorrhage (0.05 per patient) was identified. It occurred 6 months after radiosurgery. The patient showed complete recovery to a premorbid status with steroid medication. The annual hemorrhage rate after GKRS was 8.2% for the first 2 years. After the expected latency period, no hemorrhages were identified. One patient (5%) exhibited permanent paresthesia, which was a new neurologic symptom in absence of any hemorrhagic event, after the radiosurgery. GKRS seems to be relatively effective and safe for reducing the rebleeding rate of brainstem intra-axial CMs that have high surgical risk. Careful selection of a low marginal dose and an optimal radiosurgical technique are helpful to achieve good outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.
Pollock, Bruce E; Stafford, Scott L; Link, Michael J; Garces, Yolanda I; Foote, Robert L
2012-02-15
A study was undertaken to define the variables associated with tumor control and survival after single-session stereotactic radiosurgery (SRS) for patients with atypical and malignant intracranial meningiomas. Fifty patients with World Health Organization (WHO) grade II (n = 37) or grade III (n = 13) meningiomas underwent SRS from 1990 to 2008. Most tumors were located in the falx/parasagittal region or cerebral convexities (n = 35, 70%). Twenty patients (40%) had progressing tumors despite prior external beam radiation therapy (EBRT) (median dose, 54.0 grays [Gy]). The median treatment volume was 14.6 cm(3) ; the median tumor margin dose was 15.0 Gy. Seven patients (14%) received concurrent EBRT (median dose, 50.4 Gy). Follow-up (median, 38 months) was censored at last evaluation (n = 28) or death (n = 22). Tumor grade correlated with disease-specific survival (DSS) (hazard ratio [HR], 3.4; P = .008), local tumor control (HR, 2.4; P = .02), and progression-free survival (PFS) (HR, 2.6; P = .02) on univariate analysis, but not on multivariate analysis. Multivariate analysis showed that having failed EBRT and tumor volume >14.6 cm(3) were negative predictors of DSS and local control (HR, 3.0; P = .02 and HR, 4.4; P = .01; HR, 3.3; P = .001 and HR, 2.3; P = .02;, respectively). Having failed EBRT was a negative predictor of PFS (HR, 3.5; P = .002). Thirteen patients (26%) had radiation-related complications at a median of 6 months after radiosurgery. Tumor progression despite prior EBRT and larger tumor volume are negative predictors of tumor control and survival for patients having SRS for WHO grade II and III intracranial meningiomas. Copyright © 2011 American Cancer Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thibault, Isabelle; Department of Radiation Oncology, Centre Hospitalier de L'Universite de Québec–Université Laval, Quebec, Quebec; Whyne, Cari M.
Purpose: To determine a threshold of vertebral body (VB) osteolytic or osteoblastic tumor involvement that would predict vertebral compression fracture (VCF) risk after stereotactic body radiation therapy (SBRT), using volumetric image-segmentation software. Methods and Materials: A computational semiautomated skeletal metastasis segmentation process refined in our laboratory was applied to the pretreatment planning CT scan of 100 vertebral segments in 55 patients treated with spine SBRT. Each VB was segmented and the percentage of lytic and/or blastic disease by volume determined. Results: The cumulative incidence of VCF at 3 and 12 months was 14.1% and 17.3%, respectively. The median follow-up was 7.3 months (range,more » 0.6-67.6 months). In all, 56% of segments were determined lytic, 23% blastic, and 21% mixed, according to clinical radiologic determination. Within these 3 clinical cohorts, the segmentation-determined mean percentages of lytic and blastic tumor were 8.9% and 6.0%, 0.2% and 26.9%, and 3.4% and 15.8% by volume, respectively. On the basis of the entire cohort (n=100), a significant association was observed for the osteolytic percentage measures and the occurrence of VCF (P<.001) but not for the osteoblastic measures. The most significant lytic disease threshold was observed at ≥11.6% (odds ratio 37.4, 95% confidence interval 9.4-148.9). On multivariable analysis, ≥11.6% lytic disease (P<.001), baseline VCF (P<.001), and SBRT with ≥20 Gy per fraction (P=.014) were predictive. Conclusions: Pretreatment lytic VB disease volumetric measures, independent of the blastic component, predict for SBRT-induced VCF. Larger-scale trials evaluating our software are planned to validate the results.« less
NASA Astrophysics Data System (ADS)
Markwardt, Niklas; Götz, Marcus; Haj-Hosseini, Neda; Hollnburger, Bastian; Sroka, Ronald; Stepp, Herbert; Zelenkov, Petr; Rühm, Adrian
2016-04-01
5-aminolevulinic-acid-(5-ALA)-induced protoporphyrin IX (PpIX) fluorescence may be used to improve stereotactic brain tumor biopsies. In this study, the sensitivity of PpIX-based tumor detection has been investigated for two potential excitation wavelengths (405 nm, 633 nm). Using a 200 μm fiber in contact with semi-infinite optical phantoms containing ink and Lipovenös, PpIX detection limits of 4.0 nM and 200 nM (relating to 1 mW excitation power) were determined for 405 nm and 633 nm excitation, respectively. Hence, typical PpIX concentrations in glioblastomas of a few μM should be well detectable with both wavelengths. Additionally, blood layers of selected thicknesses were placed between fiber and phantom. Red excitation was shown to be considerably less affected by blood interference: A 50 μm blood layer, for instance, blocked the 405- nm-excited fluorescence completely, but reduced the 633-nm-excited signal by less than 50%. Ray tracing simulations demonstrated that - without blood layer - the sensitivity advantage of 405 nm rises for decreasing fluorescent volume from 50-fold to a maximum of 100-fold. However, at a tumor volume of 1 mm3, which is a typical biopsy sample size, the 633-nm-excited fluorescence signal is only reduced by about 10%. Further simulations revealed that with increasing fiber-tumor distance, the signal drops faster for 405 nm. This reduces the risk of detecting tumor tissue outside the needle's coverage, but diminishes the overlap between optically and mechanically sampled volumes. While 405 nm generally offers a higher sensitivity, 633 nm is more sensitive to distant tumors and considerably superior in case of blood-covered tumor tissue.
Toesca, Diego A S; Osmundson, Evan C; von Eyben, Rie; Shaffer, Jenny L; Koong, Albert C; Chang, Daniel T
This study aims to determine how the albumin-bilirubin (ALBI) score compares with the Child-Pugh (CP) score for assessing liver function following stereotactic body radiation therapy (SBRT). In total, 60 patients, 40 with hepatocellular carcinoma (HCC) and 20 with cholangiocarcinoma (CCA), were treated with SBRT. Liver function panels were obtained before and at 1, 3, 6, and 12 months after SBRT. Laboratory values were censored after locoregional recurrence, further liver-directed therapies, or liver transplant. A significant decline in hepatic function occurred after SBRT for HCC patients only (P = .001 by ALBI score; P < .0001 by CP score). By converting radiation doses to biologically equivalent doses by using a standard linear quadratic model using α/β of 10, the strongest dosimetric predictor of liver function decline for HCC was the volume of normal liver irradiated by a dose of 40 Gy when assessing liver function by the ALBI score (P = .07), and the volume of normal liver irradiated by a dose of 20 Gy by using the CP score (P= .0009). For CCA patients, the volume of normal liver irradiated by a dose of 40 Gy remained the strongest dosimetric predictor when using the ALBI score (P = .002), but no dosimetric predictor was significant using the CP score. Hepatic function decline correlated with worse overall survival for HCC (by ALBI, P = .0005; by CP, P < .0001) and for CCA (by ALBI, P = NS; by CP, P = .008). ALBI score was similarly able to predict hepatic function decline compared with CP score, and both systems correlated with survival. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.
Sheth, N; Chen, Y; Yang, J
2012-06-01
The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. Single isocenter intracranial SRS plans were created to treat the center of a solid water anthropomorphism head phantom for each GammaKnife collimator (4 mm, 8 mm, 14 mm, and 18 mm). The dose gradient, defined as the difference of effective radii of spheres equal to half and full Rx volumes, and Rx treatment volume was analyzed for isodoses from 99% to 20% of Rx. The dosimetric data on Rx volume and dose gradient vs. Rx isodose for each collimator was compiled into an easy to read nomogram as well as plotted graphically. The 4, 8, 14, and 18 mm collimators have the sharpest dose gradient at the 64%, 70%, 76%, and 77% Rx isodose lines, respectively. This corresponds to treating 4.77 mm, 8.86 mm, 14.78 mm, and 18.77 mm diameter targets with dose gradients radii of 1.06 mm, 1.63 mm, 2.54 mm, and 3.17 mm, respectively. We analyzed the dosimetric data for the most recent version of GammaPlan treatment planning software to develop tools that when applied clinically will aid in the selection of a collimator and Rx isodose line for optimal dose gradient and target coverage for single isocenter intracranial SRS with GammaKnife 4C. © 2012 American Association of Physicists in Medicine.
HFSRT of the resection cavity in patients with brain metastases.
Specht, Hanno M; Kessel, Kerstin A; Oechsner, Markus; Meyer, Bernhard; Zimmer, Claus; Combs, Stephanie E
2016-06-01
Aim of this single center, retrospective study was to assess the efficacy and safety of linear accelerator-based hypofractionated stereotactic radiotherapy (HFSRT) to the resection cavity of brain metastases after surgical resection. Local control (LC), locoregional control (LRC = new brain metastases outside of the treatment volume), overall survival (OS) as well as acute and late toxicity were evaluated. 46 patients with large (> 3 cm) or symptomatic brain metastases were treated with HFSRT. Median resection cavity volume was 14.16 cm(3) (range 1.44-38.68 cm(3)) and median planning target volume (PTV) was 26.19 cm(3) (range 3.45-63.97 cm(3)). Patients were treated with 35 Gy in 7 fractions prescribed to the 95-100 % isodose line in a stereotactic treatment setup. LC and LRC were assessed by follow-up magnetic resonance imaging. The 1-year LC rate was 88 % and LRC was 48 %; 57% of all patients showed cranial progression after HFSRT (4% local, 44% locoregional, 9% local and locoregional). The median follow-up was 19 months; median OS for the whole cohort was 25 months. Tumor histology and recursive partitioning analysis score were significant predictors for OS. HFSRT was tolerated well without any severe acute side effects > grade 2 according to CTCAE criteria. HFSRT after surgical resection of brain metastases was tolerated well without any severe acute side effects and led to excellent LC and a favorable OS. Since more than half of the patients showed cranial progression after local irradiation of the resection cavity, close patient follow-up is warranted. A prospective evaluation in clinical trials is currently being performed.
Habets, Esther J.J.; Dirven, Linda; Wiggenraad, Ruud G.; Verbeek-de Kanter, Antoinette; Lycklama à Nijeholt, Geert J.; Zwinkels, Hanneke; Klein, Martin; Taphoorn, Martin J.B.
2016-01-01
Background Stereotactic radiotherapy (SRT) is expected to have a less detrimental effect on neurocognitive functioning and health-related quality of life (HRQoL) than whole-brain radiotherapy. To evaluate the impact of brain metastases and SRT on neurocognitive functioning and HRQoL, we performed a prospective study. Methods Neurocognitive functioning and HRQoL of 97 patients with brain metastases were measured before SRT and 1, 3, and 6 months after SRT. Seven cognitive domains were assessed. HRQoL was assessed with the European Organisation for Research and Treatment of Cancer (EORTC) QLQ-C30 and BN20 questionnaires. Neurocognitive functioning and HRQoL over time were analyzed with linear mixed models and stratified for baseline Karnofsky performance status (KPS), total metastatic volume, and systemic disease. Results Median overall survival of patients was 7.7 months. Before SRT, neurocognitive domain and HRQoL scores were lower in patients than in healthy controls. At group level, patients worsened in physical functioning and fatigue at 6 months, while other outcome parameters of HRQoL and cognition remained stable. KPS < 90 and tumor volume >12.6 cm3 were both associated with worse information processing speed and lower HRQoL scores over 6 months time. Intracranial tumor progression was associated with worsening of executive functioning and motor function. Conclusions Prior to SRT, neurocognitive functioning and HRQoL are moderately impaired in patients with brain metastases. Lower baseline KPS and larger tumor volume are associated with worse functioning. Over time, SRT does not have an additional detrimental effect on neurocognitive functioning and HRQoL, suggesting that SRT may be preferred over whole-brain radiotherapy. PMID:26385615