Sample records for heu transparency implementation

  1. 2004 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2005-04-01

    During the 2004 calendar year, LLNL provided health physics support for the Highly Enriched Uranium Transparency Implementation Program (HEU-TIP) in external and internal radiation protection and technical expertise into matters related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2004, there were 200 person-trips that required dose monitoring of the U.S. monitors. Of the 200 person-trips, 183 person-trips were SMVs and 17 person-trips were Transparency Monitoring Office (TMO) trips. Eight person-trips from the SMV trips were continuation trips of TMO monitors to facilities other than UEIP. The LLNL Safety Laboratories' Division provided the dosimetrymore » services for the HEU-TIP monitors.« less

  2. 2009 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2010-04-14

    During the 2009 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2009, there were 159 person-trips that required dose monitoring of the U.S. monitors. Of the 159 person-trips, 149 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 4 monitoring visits by TMO monitors to facilities other than UEIE and 10 to UEIE itself. LLNL's Hazard Control Departmentmore » laboratories provided the dosimetry services for the HEU Transparency monitors. In 2009, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency Program now has over fifteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benton, J; Wall, D; Parker, E

    This paper presents the latest information on one of the Accelerated Highly Enriched Uranium (HEU) Disposition initiatives that resulted from the May 2002 Summit meeting between Presidents George W. Bush and Vladimir V. Putin. These initiatives are meant to strengthen nuclear nonproliferation objectives by accelerating the disposition of nuclear weapons-useable materials. The HEU Transparency Implementation Program (TIP), within the National Nuclear Security Administration (NNSA) is working to implement one of the selected initiatives that would purchase excess Russian HEU (93% 235U) for use as fuel in U.S. research reactors over the next ten years. This will parallel efforts to convertmore » the reactors' fuel core from HEU to low enriched uranium (LEU) material, where feasible. The paper will examine important aspects associated with the U.S. research reactor HEU purchase. In particular: (1) the establishment of specifications for the Russian HEU, and (2) transportation safeguard considerations for moving the HEU from the Mayak Production Facility in Ozersk, Russia, to the Y-12 National Security Complex in Oak Ridge, TN.« less

  4. 2011 Annual Health Physics Report for the HEU transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2012-04-30

    During the 2008 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. They also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2008, there were 158 person-trips that required dose monitoring of the U.S. monitors. Of the 158 person-trips, 148 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 6 monitoring visits by TMO monitors to facilities other than UEIE and 8 to UEIE itself. There were three monitoringmore » visits (source changes) that were back-to-back with a total of 24 monitors. LLNL's Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors. In 2008, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency now has thirteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less

  5. 2008 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R.

    2009-03-24

    During the 2008 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. They also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2008, there were 158 person-trips that required dose monitoring of the U.S. monitors. Of the 158 person-trips, 148 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 6 monitoring visits by TMO monitors to facilities other than UEIE and 8 to UEIE itself. There were three monitoringmore » visits (source changes) that were back-to-back with a total of 24 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors. In 2008, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency now has thirteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less

  6. 2007 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2008-04-09

    During the 2007 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection and technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2007, there were 172 person-trips that required dose monitoring of the U.S. monitors. Of the 172 person-trips, 160 person-trips were SMVs and 12 person-trips were Transparency Monitoring Office (TMO) trips. There were 12 monitoring visits by TMO monitors to facilities other than UEIE and 10 to UEIE itself. There were two monitoring visits (sourcemore » changes) that were back to back with 14 monitors. LLNL's Hazard Control Division laboratories provided the dosimetry services for the HEU Transparency monitors.« less

  7. 2010 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, Radoslav

    2011-05-16

    During the 2010 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2010, there were 141 person-trips that required dose monitoring of the U.S. monitors. Of the 141 person-trips, 129 person-trips were Special Monitoring Visits (SMVs) and 12 person-trips were Transparency Monitoring Office (TMO) trips. In 8 of these TMO trips the TMO monitors participated also in the UEIE SMVs and in 2 TMOmore » trips the TMO monitors participated in UEIE and MPA SMVs. There were three monitoring visits (source changes) that were back-to-back SMVs with a total of 25 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors.« less

  8. 2005 Annual Health Physics Report for HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2006-04-21

    During the 2005 calendar year, LLNL provided health physics support for the Highly Enriched Uranium Transparency Program (HEU-TP) in external and internal radiation protection and technical expertise into matters related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2005, there were 161 person-trips that required dose monitoring of the U.S. monitors. Of the 161 person-trips, 149 person-trips were SMVs and 12 person-trips were Transparency Monitoring Office (TMO) trips. Additionally, there were 11 monitoring visits by TMO monitors to facilities other than UEIE and 3 to UEIE itself. There were two monitoring visits (source changes)more » that were back to back with 16 monitors. Each of these concurring visits were treated as single person-trips for dosimetry purposes. Counted individually, there were 191 individual person-visits in 2005. The LLNL Safety Laboratories Division provided the dosimetry services for the HEU-TP monitors.« less

  9. Technical solutions to nonproliferation challenges

    NASA Astrophysics Data System (ADS)

    Satkowiak, Lawrence

    2014-05-01

    The threat of nuclear terrorism is real and poses a significant challenge to both U.S. and global security. For terrorists, the challenge is not so much the actual design of an improvised nuclear device (IND) but more the acquisition of the special nuclear material (SNM), either highly enriched uranium (HEU) or plutonium, to make the fission weapon. This paper provides two examples of technical solutions that were developed in support of the nonproliferation objective of reducing the opportunity for acquisition of HEU. The first example reviews technologies used to monitor centrifuge enrichment plants to determine if there is any diversion of uranium materials or misuse of facilities to produce undeclared product. The discussion begins with a brief overview of the basics of uranium processing and enrichment. The role of the International Atomic Energy Agency (IAEA), its safeguard objectives and how the technology evolved to meet those objectives will be described. The second example focuses on technologies developed and deployed to monitor the blend down of 500 metric tons of HEU from Russia's dismantled nuclear weapons to reactor fuel or low enriched uranium (LEU) under the U.S.-Russia HEU Purchase Agreement. This reactor fuel was then purchased by U.S. fuel fabricators and provided about half the fuel for the domestic power reactors. The Department of Energy established the HEU Transparency Program to provide confidence that weapons usable HEU was being blended down and thus removed from any potential theft scenario. Two measurement technologies, an enrichment meter and a flow monitor, were combined into an automated blend down monitoring system (BDMS) and were deployed to four sites in Russia to provide 24/7 monitoring of the blend down. Data was downloaded and analyzed periodically by inspectors to provide the assurances required.

  10. Technical solutions to nonproliferation challenges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Satkowiak, Lawrence

    2014-05-09

    The threat of nuclear terrorism is real and poses a significant challenge to both U.S. and global security. For terrorists, the challenge is not so much the actual design of an improvised nuclear device (IND) but more the acquisition of the special nuclear material (SNM), either highly enriched uranium (HEU) or plutonium, to make the fission weapon. This paper provides two examples of technical solutions that were developed in support of the nonproliferation objective of reducing the opportunity for acquisition of HEU. The first example reviews technologies used to monitor centrifuge enrichment plants to determine if there is any diversionmore » of uranium materials or misuse of facilities to produce undeclared product. The discussion begins with a brief overview of the basics of uranium processing and enrichment. The role of the International Atomic Energy Agency (IAEA), its safeguard objectives and how the technology evolved to meet those objectives will be described. The second example focuses on technologies developed and deployed to monitor the blend down of 500 metric tons of HEU from Russia's dismantled nuclear weapons to reactor fuel or low enriched uranium (LEU) under the U.S.-Russia HEU Purchase Agreement. This reactor fuel was then purchased by U.S. fuel fabricators and provided about half the fuel for the domestic power reactors. The Department of Energy established the HEU Transparency Program to provide confidence that weapons usable HEU was being blended down and thus removed from any potential theft scenario. Two measurement technologies, an enrichment meter and a flow monitor, were combined into an automated blend down monitoring system (BDMS) and were deployed to four sites in Russia to provide 24/7 monitoring of the blend down. Data was downloaded and analyzed periodically by inspectors to provide the assurances required.« less

  11. 31 CFR 540.305 - HEU Agreements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false HEU Agreements. 540.305 Section 540.305 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... current and future amendments thereto; as well as the related current and future implementing agreements...

  12. 31 CFR 540.305 - HEU Agreements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false HEU Agreements. 540.305 Section 540.305 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... current and future amendments thereto; as well as the related current and future implementing agreements...

  13. 31 CFR 540.305 - HEU Agreements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false HEU Agreements. 540.305 Section 540.305 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... current and future amendments thereto; as well as the related current and future implementing agreements...

  14. White Matter Microstructural Integrity and Neurobehavioral Outcome of HIV-Exposed Uninfected Neonates.

    PubMed

    Tran, Linh T; Roos, Annerine; Fouche, Jean-Paul; Koen, Nastassja; Woods, Roger P; Zar, Heather J; Narr, Katherine L; Stein, Dan J; Donald, Kirsten A

    2016-01-01

    The successful implementation of prevention programs for mother-to-child human immunodeficiency virus (HIV) transmission has dramatically reduced the prevalence of infants infected with HIV while increasing that of HIV-exposed uninfected (HEU) children. Neuropsychological assessments indicate that HEU children may exhibit differences in neurodevelopment compared to unexposed children (HUU). Pathological mechanisms leading to such neurodevelopmental delays are not clear. In this observational birth cohort study we explored the integrity of regional white matter microstructure in HEU infants, shortly after birth. Microstructural changes in white matter associated with prenatal HIV exposure were evaluated in HEU infants (n = 15) and matched controls (n = 22) using diffusion tensor imaging and tract-based spatial statistics. Additionally, diffusion values were extracted and compared for white matter tracts of interest, and associations with clinical outcomes from the Dubowitz neonatal neurobehavioral tool were investigated. Higher fractional anisotropy in the middle cerebellar peduncles of HEU compared to HUU neonates was found after correction for age and gender. Scores on the Dubowitz abnormal neurological signs subscale were positively correlated with FA (r = 0.58, P = 0.038) in the left uncinate fasciculus in HEU infants. This is the first study to present data suggesting that prenatal HIV exposure without infection is associated with altered white matter microstructural integrity in the neonatal period. Longitudinal studies of HEU infants as their brains mature are necessary to understand further the significance of prenatal HIV and antiretroviral treatment exposure on white matter integrity and neurodevelopmental outcomes.

  15. Feasibility study for early removal of HEU from CPP-651-Phase II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, C.V.; Henry, R.; Milligan, C.

    1997-09-01

    A two-phase feasibility study was initiated in late 1996 to identify a way to expedite the removal of SNM from the CPP-651 vault. The first phase of this study provided preliminary information that appeared promising, but needed additional detailed planning and evaluate to validate the concepts and conclusions. The focus of Phase 2 was to provide the validation via resource-loaded schedules and more detailed cost estimates. Section 1 describes the purpose and objectives of the Phase 2 tasks and the programmatic drivers that influence related CPP-651 high-enriched uranium (HEU) management issues. Section 2 identifies the evaluation criteria and methodology andmore » the transfer issues and barriers preventing shipment. Section 3 provides site-specific background information for the CPP-651 facility and the Idaho National Engineering and Environmental Laboratory (INEEL) and describes the development of the basic material removal schedule, the proposed base case plan for removal of SNM, and the proposed HEU material management/shipping issues and strategies. Section 4 identifies the proposed options for accelerated removal of SNM and how they were evaluated via detailed scheduling, resource histograms, and cost analysis. Section 5 summarizes principal tasks for implementing this plan and other related HEU CPP-651 management issues that require continued planning efforts to assure successful implementation of this proposed early removal strategy.« less

  16. Altered Memory T-Cell Responses to Bacillus Calmette-Guerin and Tetanus Toxoid Vaccination and Altered Cytokine Responses to Polyclonal Stimulation in HIV-Exposed Uninfected Kenyan Infants.

    PubMed

    Garcia-Knight, Miguel A; Nduati, Eunice; Hassan, Amin S; Gambo, Faith; Odera, Dennis; Etyang, Timothy J; Hajj, Nassim J; Berkley, James Alexander; Urban, Britta C; Rowland-Jones, Sarah L

    2015-01-01

    Implementation of successful prevention of mother-to-child transmission of HIV strategies has resulted in an increased population of HIV-exposed uninfected (HEU) infants. HEU infants have higher rates of morbidity and mortality than HIV-unexposed (HU) infants. Numerous factors may contribute to poor health in HEU infants including immunological alterations. The present study assessed T-cell phenotype and function in HEU infants with a focus on memory Th1 responses to vaccination. We compared cross-sectionally selected parameters at 3 and 12 months of age in HIV-exposed (n = 42) and HU (n = 28) Kenyan infants. We measured ex vivo activated and bulk memory CD4 and CD8 T-cells and regulatory T-cells by flow cytometry. In addition, we measured the magnitude, quality and memory phenotype of antigen-specific T-cell responses to Bacillus Calmette-Guerin and Tetanus Toxoid vaccine antigens, and the magnitude and quality of the T cell response following polyclonal stimulation with staphylococcal enterotoxin B. Finally, the influence of maternal disease markers on the immunological parameters measured was assessed in HEU infants. Few perturbations were detected in ex vivo T-cell subsets, though amongst HEU infants maternal HIV viral load positively correlated with CD8 T cell immune activation at 12 months. Conversely, we observed age-dependent differences in the magnitude and polyfunctionality of IL-2 and TNF-α responses to vaccine antigens particularly in Th1 cells. These changes mirrored those seen following polyclonal stimulation, where at 3 months, cytokine responses were higher in HEU infants compared to HU infants, and at 12 months, HEU infant cytokine responses were consistently lower than those seen in HU infants. Finally, reduced effector memory Th1 responses to vaccine antigens were observed in HEU infants at 3 and 12 months and higher central memory Th1 responses to M. tuberculosis antigens were observed at 3 months only. Long-term monitoring of vaccine efficacy and T-cell immunity in this vulnerable population is warranted.

  17. 2 x 2 Polyethylene Reflected and Moderated Highly Enriched Uranium System with Rhenium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Nichole Ellis; Jesson Hutchinson; John D. Bess

    2010-09-01

    The 2 × 2 array HEU-Re experiment was performed on the Planet universal critical assembly machine on November 4th, 2003 at the Los Alamos Critical Experiments Facility (LACEF) at Los Alamos National Laboratory (LANL). For this experiment, there were 10 ½ units, each full unit containing four HEU foils and two rhenium foils. The top unit contained only two HEU foils and two rhenium foils. A total of 42 HEU foils were used for this experiment. Rhenium is a desirable cladding material for space nuclear power applications. This experiment consisted of HEU foils interleaved with rhenium foils and is moderatedmore » and reflected by polyethylene plates. A unit consisted of a polyethylene plate, which has a recess for rhenium foils, and four HEU foils in a single layer in the top recess of each polyethylene plate. The Planet universal criticality assembly machine has been previously used in experiments containing HEU foils interspersed with SiO2 (HEU-MET-THERM-001), Al (HEU-MET-THERM-008), MgO (HEU-MET-THERM-009), Gd foils (HEU-MET-THERM-010), 2 × 2 × 26 Al (HEU-MET-THERM-012), Fe (HEU-MET-THERM-013 and HEU-MET-THERM-015), 2 × 2 × 23 SiO2 (HEU-MET-THERM-014), 2 × 2 × 11 hastalloy plates (HEU-MET-THERM-016), and concrete (HEU-MET-THERM-018). The 2 × 2 array of HEU-Re is considered acceptable for use as a benchmark critical experiment.« less

  18. 31 CFR 540.305 - HEU Agreements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false HEU Agreements. 540.305 Section 540... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.305 HEU Agreements. The term HEU Agreements means the Agreement Between...

  19. 31 CFR 540.305 - HEU Agreements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false HEU Agreements. 540.305 Section 540... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.305 HEU Agreements. The term HEU Agreements means the Agreement Between...

  20. Implementing New Methods of Laser Marking of Items in the Nuclear Material Control and Accountability System at SSC RF-IPPE: An Automated Laser Marking System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regoushevsky, V I; Tambovtsev, S D; Dvukhsherstnov, V G

    2009-05-18

    For over ten years SSC RF-IPPE, together with the US DOE National Laboratories, has been working on implementing automated control and accountability methods for nuclear materials and other items. Initial efforts to use adhesive bar codes or ones printed (painted) onto metal revealed that these methods were inconvenient and lacked durability under operational conditions. For NM disk applications in critical stands, there is the additional requirement that labels not affect the neutron characteristics of the critical assembly. This is particularly true for the many stainless-steel clad disks containing highly enriched uranium (HEU) and plutonium that are used at SSC RF-IPPEmore » for modeling nuclear power reactors. In search of an alternate method for labeling these disks, we tested several technological options, including laser marking and two-dimensional codes. As a result, the method of laser coloring was chosen in combination with Data Matrix ECC200 symbology. To implement laser marking procedures for the HEU disks and meet all the nuclear material (NM) handling standards and rules, IPPE staff, with U.S. technical and financial support, implemented an automated laser marking system; there are also specially developed procedures for NM movements during laser marking. For the laser marking station, a Zenith 10F system by Telesis Technologies (10 watt Ytterbium Fiber Laser and Merlin software) is used. The presentation includes a flowchart for the automated system and a list of specially developed procedures with comments. Among other things, approaches are discussed for human-factor considerations. To date, markings have been applied to numerous steel-clad HEU disks, and the work continues. In the future this method is expected to be applied to other MC&A items.« less

  1. No Difference in Antibody Responses to Tetanus Vaccine Among HIV-Exposed and -Unexposed Infants in Botswana

    PubMed Central

    Smith, Christiana; Moraka, Natasha; Ibrahim, Maryanne; Moyo, Sikhulile; Mayondi, Gloria; Kammerer, Betsy; Leidner, Jean; Gaseitsiwe, Simani; Lockman, Shahin; Weinberg, Adriana

    2017-01-01

    Abstract Background In Botswana, more than 10% of HIV-exposed, uninfected infants (HEU) are hospitalized or die in the first 6 months of life, largely due to infectious causes. Vaccine responses can act as a marker of the immune response to infectious antigens. Previous studies of antibody responses to vaccines in HEU have had conflicting results. We compared antibody titers to tetanus vaccine between HEU and HIV-unexposed infants (HUU), and explored whether tetanus antibody titers predicted risk of hospitalization in the first 2 years of life among HEU. Methods 443 HIV-infected and 451 HIV-uninfected mothers and their 453 HEU / 457 HUU live-born infants were followed in a prospective observational study in Botswana (“Tshipidi”). Quantitative tetanus toxoid IgG was measured in plasma samples from 18-month-old infants. Geometric mean antibody titers (GMT) were compared between HEU and HUU infants, and between HEU infants who were or were not hospitalized by age 2. Results Plasma was available at 18 months for 39 HEU and 42 HUU infants. Within this subset, there were 15 hospitalizations (12 in HEU) [RR of hospitalization among HEU = 1.34 (P = 0.009)]. 73% of hospitalizations overall, and 83% in HEU, were due to infection (primarily pneumonia/bronchiolitis and gastroenteritis). Among infants who had received 3 or 4 doses of tetanus vaccine by 18 months, there were no significant differences in tetanus GMT between HEU and HUU (Fig A). Among HEU who had received 3 or 4 doses of tetanus vaccine by 18 months, there were no significant differences in tetanus GMT between infants who were hospitalized and infants who were not (Fig B). Conclusion In this small sample of infants from Botswana, we did not identify differences in antibody responses to tetanus vaccine between HEU and HUU. Although HEU demonstrated an increased risk of hospitalization, response to tetanus vaccine did not appear to be a significant predictor of morbidity. It is possible that cell-mediated immune defects play a larger role than humoral immune defects in the increased susceptibility to infection among HEU. Disclosures All authors: No reported disclosures.

  2. The Immune System of HIV-Exposed Uninfected Infants.

    PubMed

    Abu-Raya, Bahaa; Kollmann, Tobias R; Marchant, Arnaud; MacGillivray, Duncan M

    2016-01-01

    Infants born to human immunodeficiency virus (HIV) infected women are HIV-exposed but the majority remains uninfected [i.e., HIV-exposed uninfected (HEU)]. HEU infants suffer greater morbidity and mortality from infections compared to HIV-unexposed (HU) peers. The reason(s) for these worse outcomes are uncertain, but could be related to an altered immune system state. This review comprehensively summarizes the current literature investigating the adaptive and innate immune system of HEU infants. HEU infants have altered cell-mediated immunity, including impaired T-cell maturation with documented hypo- as well as hyper-responsiveness to T-cell activation. And although prevaccination vaccine-specific antibody levels are often lower in HEU than HU, most HEU infants mount adequate humoral immune response following primary vaccination with diphtheria toxoid, haemophilus influenzae type b, whole cell pertussis, measles, hepatitis B, tetanus toxoid, and pneumococcal conjugate vaccines. However, HEU infants are often found to have lower absolute neutrophil counts as compared to HU infants. On the other hand, an increase of innate immune cytokine production and expression of co-stimulatory markers has been noted in HEU infants, but this increase appears to be restricted to the first few weeks of life. The immune system of HEU children beyond infancy remains largely unexplored.

  3. 31 CFR 540.306 - Highly Enriched Uranium (HEU).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Highly Enriched Uranium (HEU). 540...) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.306 Highly Enriched Uranium (HEU). The term highly...

  4. 31 CFR 540.306 - Highly Enriched Uranium (HEU).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Highly Enriched Uranium (HEU). 540.306... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.306 Highly Enriched Uranium (HEU). The term highly enriched...

  5. 31 CFR 540.306 - Highly Enriched Uranium (HEU).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Highly Enriched Uranium (HEU). 540.306... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.306 Highly Enriched Uranium (HEU). The term highly enriched...

  6. 31 CFR 540.306 - Highly Enriched Uranium (HEU).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Highly Enriched Uranium (HEU). 540.306... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.306 Highly Enriched Uranium (HEU). The term highly enriched...

  7. 31 CFR 540.306 - Highly Enriched Uranium (HEU).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Highly Enriched Uranium (HEU). 540.306... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.306 Highly Enriched Uranium (HEU). The term highly enriched...

  8. United States and Russian Cooperation on Issues of Nuclear Nonproliferation

    DTIC Science & Technology

    2005-06-01

    Reactors ( RERTR ) This project works with Russia to facilitate conversion of its research and test reactors from highly enriched uranium (HEU) fuel...reactor fuel purchase, accelerated RERTR activities, and accelerated Material Conversion and Consolidation implementation. 89 j. Fissile Materials

  9. Impaired haemophilus influenzae type b transplacental antibody transmission and declining antibody avidity through the first year of life represent potential vulnerabilities for HIV-exposed but -uninfected infants.

    PubMed

    Gaensbauer, James T; Rakhola, Jeremy T; Onyango-Makumbi, Carolyne; Mubiru, Michael; Westcott, Jamie E; Krebs, Nancy F; Asturias, Edwin J; Fowler, Mary Glenn; McFarland, Elizabeth; Janoff, Edward N

    2014-12-01

    To determine whether immune function is impaired among HIV-exposed but -uninfected (HEU) infants born to HIV-infected mothers and to identify potential vulnerabilities to vaccine-preventable infection, we characterized the mother-to-infant placental transfer of Haemophilus influenzae type b-specific IgG (Hib-IgG) and its levels and avidity after vaccination in Ugandan HEU infants and in HIV-unexposed U.S. infants. Hib-IgG was measured by enzyme-linked immunosorbent assay in 57 Ugandan HIV-infected mothers prenatally and in their vaccinated HEU infants and 14 HIV-unexposed U.S. infants at birth and 12, 24, and 48 weeks of age. Antibody avidity at birth and 48 weeks of age was determined with 1 M ammonium thiocyanate. A median of 43% of maternal Hib-IgG was transferred to HEU infants. Although its level was lower in HEU infants than in U.S. infants at birth (P < 0.001), Hib-IgG was present at protective levels (>1.0 μg/ml) at birth in 90% of HEU infants and all U.S. infants. HEU infants had robust Hib-IgG responses to a primary vaccination. Although Hib-IgG levels declined from 24 to 48 weeks of age in HEU infants, they were higher than those in U.S. infants (P = 0.002). Antibody avidity, comparable at birth, declined by 48 weeks of age in both populations. Early vaccination of HEU infants may limit an initial vulnerability to Hib disease resulting from impaired transplacental antibody transfer. While initial Hib vaccine responses appeared adequate, the confluence of lower antibody avidity and declining Hib-IgG levels in HEU infants by 12 months support Hib booster vaccination at 1 year. Potential immunologic impairments of HEU infants should be considered in the development of vaccine platforms for populations with high maternal HIV prevalence. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  10. Neurodevelopmental outcome of HIV-exposed but uninfected infants in the Mother and Infants Health Study, Cape Town, South Africa.

    PubMed

    Springer, Priscilla E; Slogrove, Amy L; Laughton, Barbara; Bettinger, Julie A; Saunders, Henriëtte H; Molteno, Christopher D; Kruger, Mariana

    2018-01-01

    To compare neurodevelopmental outcomes of HIV-exposed uninfected (HEU) and HIV-unexposed uninfected (HUU) infants in a peri-urban South African population. HEU infants living in Africa face unique biological and environmental risks, but uncertainty remains regarding their neurodevelopmental outcome. This is partly due to lack of well-matched HUU comparison groups needed to adjust for confounding factors. This was a prospective cohort study of infants enrolled at birth from a low-risk midwife obstetric facility. At 12 months of age, HEU and HUU infant growth and neurodevelopmental outcomes were compared. Growth was evaluated as WHO weight-for-age, length-for-age, weight-for-length and head-circumference-for-age Z-scores. Neurodevelopmental outcomes were evaluated using the Bayley scales of Infant Development III (BSID) and Alarm Distress Baby Scale (ADBB). Fifty-eight HEU and 38 HUU infants were evaluated at 11-14 months of age. Performance on the BSID did not differ in any of the domains between HEU and HUU infants. The cognitive, language and motor scores were within the average range (US standardised norms). Seven (12%) HEU and 1 (2.6%) HUU infant showed social withdrawal on the ADBB (P = 0.10), while 15 (26%) HEU and 4 (11%) HUU infants showed decreased vocalisation (P = 0.06). There were no growth differences. Three HEU and one HUU infant had minor neurological signs, while eight HEU and two HUU infants had macrocephaly. Although findings on the early neurodevelopmental outcome of HEU infants are reassuring, minor differences in vocalisation and on neurological examination indicate a need for reassessment at a later age. © 2017 John Wiley & Sons Ltd.

  11. An Assessment of the Detection of Highly Enriched Uranium and its Use in an Improvised Nuclear Device using the Monte Carlo Computer Code MCNP-5

    NASA Astrophysics Data System (ADS)

    Cochran, Thomas

    2007-04-01

    In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined via Monte Carlo criticality calculations. Nuclear explosive yields of such an IND as a function of the speed of assembly of the sub-critical HEU components were derived. A comparison was made between the more rapid assembly of sub-critical pieces of HEU in the ``Little Boy'' (Hiroshima) weapon's gun barrel and gravity assembly (i.e., dropping one sub-critical piece of HEU on another from a specified height). Based on the difficulty of detection of HEU and the straightforward construction of an IND utilizing HEU, current U.S. government policy must be modified to more urgently prioritize elimination of and securing the global inventories of HEU.

  12. Reactor Physics Scoping and Characterization Study on Implementation of TRIGA Fuel in the Advanced Test Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jennifer Lyons; Wade R. Marcum; Mark D. DeHart

    2014-01-01

    The Advanced Test Reactor (ATR), under the Reduced Enrichment for Research and Test Reactors (RERTR) Program and the Global Threat Reduction Initiative (GTRI), is conducting feasibility studies for the conversion of its fuel from a highly enriched uranium (HEU) composition to a low enriched uranium (LEU) composition. These studies have considered a wide variety of LEU plate-type fuels to replace the current HEU fuel. Continuing to investigate potential alternatives to the present HEU fuel form, this study presents a preliminary analysis of TRIGA® fuel within the current ATR fuel envelopes and compares it to the functional requirements delineated by themore » Naval Reactors Program, which includes: greater than 4.8E+14 fissions/s/g of 235U, a fast to thermal neutron flux ratio that is less than 5% deviation of its current value, a constant cycle power within the corner lobes, and an operational cycle length of 56 days at 120 MW. Other parameters outside those put forth by the Naval Reactors Program which are investigated herein include axial and radial power profiles, effective delayed neutron fraction, and mean neutron generation time.« less

  13. White Paper – Use of LEU for a Space Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poston, David Irvin; Mcclure, Patrick Ray

    Historically space reactors flown or designed for the U.S. and Russia used Highly Enriched Uranium (HEU) for fuel. HEU almost always produces a small and lighter reactor. Since mass increases launch costs or decreases science payloads, HEU was the natural choice. However in today’s environment, the proliferation of HEU has become a major concern for the U.S. government and hence a policy issue. In addition, launch costs are being reduced as the space community moves toward commercial launch vehicles. HEU also carries a heavy security cost to process, test, transport and launch. Together these issues have called for a re-investigationmore » into space reactors the use Low Enriched Uranium (LEU) fuel.« less

  14. Transition Core Properties during Conversion of the NBSR from HEU to LEU Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanson, A. L.; Diamond, D.

    2013-10-31

    The transition of the NBSR from HEU to LEU fuel is challenging due to reactivity constraints and the need to maintain an uninterrupted science program, the mission of the NBSR. The transition cannot occur with a full change of HEU to LEU fuel elements since the excess reactivity would be large enough that the NBSR would violate the technical specification for shutdown margin. Manufacturing LEU fuel elements to represent irradiated fuel elements would be cost prohibitive since 26 one-of-a-kind fuel elements would need to be manufactured. For this report a gradual transition from the present HEU fuel to the proposedmore » LEU fuel was studied. The gradual change approach would follow the present fuel management scheme and replace four HEU fuel elements with four LEU fuel elements each cycle. This manuscript reports the results of a series of calculations to predict the neutronic characteristics and how the neutronics will change during the transition from HEU to LEU in the NBSR.« less

  15. Secure Transportation of HEU in Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-07-06

    The National Nuclear Security Administration has announced the final shipments of Russian-origin highly enriched uranium (HEU) nuclear fuel from Romania. The material was removed and returned to Russia by air for storage at two secure nuclear facilities, making Romania the first country to remove all HEU since President Obama outlined his commitment to securing all vulnerable nuclear material around the world within four years. This was also the first time NNSA has shipped spent HEU by airplane, a development that will help accelerate efforts to meet the Presidents objective.

  16. Disclosing in utero HIV/ARV exposure to the HIV-exposed uninfected adolescent: is it necessary?

    PubMed Central

    Jao, Jennifer; Hazra, Rohan; Mellins, Claude A; Remien, Robert H; Abrams, Elaine J

    2016-01-01

    Introduction The tremendous success of antiretroviral therapy has resulted in a diminishing population of perinatally HIV-infected children on the one hand and a mounting number of HIV-exposed uninfected (HEU) children on the other. As the oldest of these HEU children are reaching adolescence, questions have emerged surrounding the implications of HEU status disclosure to these adolescents. This article outlines the arguments for and against disclosure of a child's HEU status. Discussion Disclosure of a child's HEU status, by definition, requires disclosure of maternal HIV status. It is necessary to weigh the benefits and harms which could occur with disclosure in each of the following domains: psychosocial impact, long-term physical health of the HEU individual and the public health impact. Does disclosure improve or worsen the psychological health of the HEU individual and extended family unit? Do present data on the long-term safety of in utero HIV/ARV exposure reveal potential health risks which merit disclosure to the HEU adolescent? What research and public health programmes or systems need to be in place to afford monitoring of HEU individuals and which, if any, of these require disclosure? Conclusions At present, it is not clear that there is sufficient evidence on whether long-term adverse effects are associated with in utero HIV/ARV exposures, making it difficult to mandate universal disclosure. However, as more countries adopt electronic medical record systems, the HEU status of an individual should be an important piece of the health record which follows the infant not only through childhood and adolescence but also adulthood. Clinicians and researchers should continue to approach the dialogue around mother–child disclosure with sensitivity and a cogent consideration of the evolving risks and benefits as new information becomes available while also working to maintain documentation of an individual's perinatal HIV/ARV exposures as a vital part of his/her medical records. As more long-term adult safety data on in utero HIV/ARV exposures become available these decisions may become clearer, but at this time, they remain complex and multi-faceted. PMID:27741954

  17. Monte Carlo Shielding Comparative Analysis Applied to TRIGA HEU and LEU Spent Fuel Transport

    NASA Astrophysics Data System (ADS)

    Margeanu, C. A.; Margeanu, S.; Barbos, D.; Iorgulis, C.

    2010-12-01

    The paper is a comparative study of LEU and HEU fuel utilization effects for the shielding analysis during spent fuel transport. A comparison against the measured data for HEU spent fuel, available from the last stage of spent fuel repatriation fulfilled in the summer of 2008, is also presented. All geometrical and material data for the shipping cask were considered according to NAC-LWT Cask approved model. The shielding analysis estimates radiation doses to shipping cask wall surface, and in air at 1 m and 2 m, respectively, from the cask, by means of 3D Monte Carlo MORSE-SGC code. Before loading into the shipping cask, TRIGA spent fuel source terms and spent fuel parameters have been obtained by means of ORIGEN-S code. Both codes are included in ORNL's SCALE 5 programs package. The actinides contribution to total fuel radioactivity is very low in HEU spent fuel case, becoming 10 times greater in LEU spent fuel case. Dose rates for both HEU and LEU fuel contents are below regulatory limits, LEU spent fuel photon dose rates being greater than HEU ones. Comparison between HEU spent fuel theoretical and measured dose rates in selected measuring points shows a good agreement, calculated values being greater than the measured ones both to cask wall surface (about 34% relative difference) and in air at 1 m distance from cask surface (about 15% relative difference).

  18. AIR SHIPMENT OF HIGHLY ENRICHED URANIUM SPENT NUCLEAR FUEL FROM ROMANIA AND LIBYA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher Landers; Igor Bolshinsky; Ken Allen

    2010-07-01

    In June 2009 Romania successfully completed the world’s first air shipment of highly enriched uranium (HEU) spent nuclear fuel transported in Type B(U) casks under existing international laws and without special exceptions for the air transport licenses. Special 20-foot ISO shipping containers and cask tiedown supports were designed to transport Russian TUK 19 shipping casks for the Romanian air shipment and the equipment was certified for all modes of transport, including road, rail, water, and air. In December 2009 Libya successfully used this same equipment for a second air shipment of HEU spent nuclear fuel. Both spent fuel shipments weremore » transported by truck from the originating nuclear facilities to nearby commercial airports, were flown by commercial cargo aircraft to a commercial airport in Yekaterinburg, Russia, and then transported by truck to their final destinations at the Production Association Mayak facility in Chelyabinsk, Russia. Both air shipments were performed under the Russian Research Reactor Fuel Return Program (RRRFR) as part of the U.S. National Nuclear Security Administration (NNSA) Global Threat Reduction Initiative (GTRI). The Romania air shipment of 23.7 kg of HEU spent fuel from the VVR S research reactor was the last of three HEU fresh and spent fuel shipments under RRRFR that resulted in Romania becoming the 3rd RRRFR participating country to remove all HEU. Libya had previously completed two RRRFR shipments of HEU fresh fuel so the 5.2 kg of HEU spent fuel air shipped from the IRT 1 research reactor in December made Libya the 4th RRRFR participating country to remove all HEU. This paper describes the equipment, preparations, and license approvals required to safely and securely complete these two air shipments of spent nuclear fuel.« less

  19. Supplemental Reactor Physics Calculations and Analysis of ELF Mk 1A Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, Michael A.

    2014-10-01

    These calculations supplement previous the reactor physics work evaluating the Enhanced Low Enriched Uranium (LEU) Fuel (ELF) Mk 1A element. This includes various additional comparisons between the current Highly Enriched Uranium (HEU) and LEU along with further characterization of the performance of the ELF fuel. The excess reactivity to be held down at BOC for ELF Mk 1A fuel is estimated to be approximately $2.75 greater than with HEU for a typical cycle. This is a combined effect of the absence of burnable poison in the ELF fuel and the reduced neck shim worth in LEU fuel compared to HEU.more » Burnable poison rods were conceptualized for use in the small B positions containing Gd2O3 absorber. These were shown to provide $2.37 of negative reactivity at BOC and to burn out in less than half of a cycle. The worth of OSCCs is approximately the same between HEU and ELF Mk 1A (LEU) fuels in the representative loading evaluated. This was evaluated by rotating all banks simultaneously. The safety rod worth is relatively unchanged between HEU and ELF Mk 1A (LEU) fuels in the representative loading evaluated. However, this should be reevaluated with different loadings. Neutron flux, both total and fast (>1 MeV), is either the same or reduced upon changing from HEU to ELF Mk 1A (LEU) fuels in the representative loading evaluated. This is consistent with the well-established trend of lower neutron fluxes for a given power in LEU than HEU.The IPT loop void reactivity is approximately the same or less positive with ELF Mk 1A (LEU) fuel than HEU in the representative loading evaluated.« less

  20. Mortality risk and associated factors in HIV-exposed, uninfected children.

    PubMed

    Arikawa, Shino; Rollins, Nigel; Newell, Marie-Louise; Becquet, Renaud

    2016-06-01

    With increasing maternal antiretroviral treatment (ART), the number of children newly infected with HIV has declined. However, the possible increased mortality in the large number of HIV-exposed, uninfected (HEU) children may be of concern. We quantified mortality risks among HEU children and reviewed associated factors. Systematic search of electronic databases (PubMed, Scopus). We included all studies reporting mortality of HEU children to age 60 months and associated factors. Relative risk of mortality between HEU and HIV-unexposed, uninfected (HUU) children was extracted where relevant. Inverse variance methods were used to adjust for study size. Random-effects models were fitted to obtain pooled estimates. A total of 14 studies were included in the meta-analysis and 13 in the review of associated factors. The pooled cumulative mortality in HEU children was 5.5% (95% CI: 4.0-7.2; I(2) = 94%) at 12 months (11 studies) and 11.0% (95% CI: 7.6-15.0; I(2) = 93%) at 24 months (four studies). The pooled risk ratios for the mortality in HEU children compared to HUU children in the same setting were 1.9 (95% CI: 0.9-3.8; I(2) = 93%) at 12 months (four studies) and 2.4 (95% CI: 1.1-5.1; I(2) = 93%) at 24 months (three studies). Compared to HUU children, mortality risk in HEU children was about double at both age points, although the association was not statistically significant at 12 months. Interpretation of the pooled estimates is confounded by considerable heterogeneity between studies. Further research is needed to characterise the impact of maternal death and breastfeeding on the survival of HEU infants in the context of maternal ART, where current evidence is limited. © 2016 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  1. Summary of a joint US-Japan study of potential approaches to reduce the attractiveness of various nuclear materials for use in a nuclear explosive device by a terrorist group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bathke, C.G.; Inoue, N.; Kuno, Y.

    2013-07-01

    This paper summarizes the results of a joint US-Japan study to establish a mutual understanding, through scientific-based study, of potential approaches to reduce the attractiveness of various nuclear materials for use in a terrorist nuclear explosive device (NED). 4 approaches that can reduce materials attractiveness with a very high degree of effectiveness are: -) diluting HEU with natural or depleted U to an enrichment of less than 10% U-235; -) storing Pu in nuclear fuel that is not man portable and with a dose rate greater or equal to 10 Gy/h at 1 m; -) storing Pu or HEU inmore » heavy items, i.e. not transportable, provided the removal of the Pu or HEU from the item requires a purification/processing capability; and -) converting Pu and HEU to very dilute forms (such as wastes) that, without any security barriers, would require very long acquisition times to acquire a Category I quantity of Pu or of HEU. 2 approaches that can reduce materials attractiveness with a high degree of effectiveness are: -) converting HEU-fueled research reactors into LEU-fueled research reactors or dilute HEU with natural or depleted U to an enrichment of less than 20% U-235; -) converting U/Al reactor fuel into U/Si reactor fuel. Other approaches have been assessed as moderately or totally inefficient to reduce the attractiveness of nuclear materials.« less

  2. Impact of elevated maternal HIV viral load at delivery on T-cell populations in HIV exposed uninfected infants in Mozambique.

    PubMed

    de Deus, Nilsa; Moraleda, Cinta; Serna-Bolea, Celia; Renom, Montse; Menendez, Clara; Naniche, Denise

    2015-02-03

    HIV-uninfected infants born to HIV-infected mothers (HIV-exposed uninfected, HEU) have been described to have immune alterations as compared to unexposed infants. This study sought to characterize T-cell populations after birth in HEU infants and unexposed infants living in a semirural area in southern Mozambique. Between August 2008 and June 2009 mother-infant pairs were enrolled at the Manhiça District Hospital at delivery into a prospective observational analysis of immunological and health outcomes in HEU infants. Infants were invited to return at one month of age for a clinical examination, HIV DNA-PCR, and immunophenotypic analyses. The primary analysis sought to assess immunological differences between HEU and unexposed groups, whereas the secondary analysis assessed the impact of maternal HIV RNA viral load in the HEU group. Infants who had a positive HIV DNA-PCR test were not included in the analysis. At one month of age, the 74 HEU and the 56 unexposed infants had similar median levels of naïve, memory and activated CD8 and CD4 T-cells. Infant naïve and activated CD8 T-cells were found to be associated with maternal HIV-RNA load at delivery. HEU infants born to women with HIV-RNA loads above 5 log10 copies/mL had lower median levels of naïve CD8 T-cells (p = 0.04), and higher median levels of memory CD8 T-cells, (p = 0.014). This study suggests that exposure to elevated maternal HIV-RNA puts the infant at higher risk of having early T-cell abnormalities. Improving prophylaxis of mother to child HIV programs such that more women have undetectable viral load is crucial to decrease vertical transmission of HIV, but may also be important to reduce the consequences of HIV virus exposure in HEU infants.

  3. Cardiac effects of in-utero exposure to antiretroviral therapy in HIV-uninfected children born to HIV-infected mothers.

    PubMed

    Lipshultz, Steven E; Williams, Paige L; Zeldow, Bret; Wilkinson, James D; Rich, Kenneth C; van Dyke, Russell B; Seage, George R; Dooley, Laurie B; Kaltman, Jonathan R; Siberry, George K; Mofenson, Lynne M; Shearer, William T; Colan, Steven D

    2015-01-02

    We evaluated the potential cardiac effects of in-utero exposures to antiretroviral drugs in HIV-exposed but uninfected (HEU) children. We compared echocardiographic parameters of left ventricular function (ejection fraction, fractional shortening, and stress-velocity index) and structure (left ventricular dimension, posterior wall/septal thickness, mass, thickness-to-dimension ratio, and wall stress) (expressed as Z-scores to account for age and body surface area) between HEU and HIV-unexposed cohorts from the Pediatric HIV/AIDS Cohort Study's Surveillance Monitoring for ART Toxicities study. Within the HEU group, we investigated the associations between the echocardiographic Z-scores and in-utero exposures to maternal antiretroviral drugs. There were no significant differences in echocardiographic Z-scores between 417 HEU and 98 HIV-unexposed children aged 2-7 years. Restricting the analysis to HEU children, first-trimester exposures to combination antiretroviral therapy (a regimen including at least three antiretroviral drugs) and to certain specific antiretroviral drugs were associated with significantly lower stress-velocity Z-scores (mean decreases of 0.22-0.40 SDs). Exposure to combination antiretroviral therapy was also associated with lower left ventricular dimension Z-scores (mean decrease of 0.44 SD). First-trimester exposure to combination antiretroviral therapy was associated with higher mean left ventricular posterior wall thickness and lower mean left ventricular wall stress Z-scores. There was no evidence of significant cardiac toxicity of perinatal combination antiretroviral therapy exposure in HEU children. Subclinical differences in left ventricular structure and function with specific in-utero antiretroviral exposures indicate the need for a longitudinal cardiac study in HEU children to assess long-term cardiac risk and cardiac monitoring recommendations.

  4. Russia ties HEU sale to suspension agreement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-11-01

    Unless the US government allows the Russians access to the US uranium fuel market, the successful completion of a high-enriched uranium (HEU) sales agreement between the two governments may be in jeopardy. It had been rumored that the Russians, who have been unhappy about the stiff tariffs imposed on former Soviet uranium in the US market, might use the ongoing HEU negotiations with the White House to ease the antidumping tariffs imposed by the Department of Commerce's International Trade Commission.

  5. Impact of the High Flux Isotope Reactor HEU to LEU Fuel Conversion on Cold Source Nuclear Heat Generation Rates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandler, David

    2014-03-01

    Under the sponsorship of the US Department of Energy National Nuclear Security Administration, staff members at the Oak Ridge National Laboratory have been conducting studies to determine whether the High Flux Isotope Reactor (HFIR) can be converted from high enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. As part of these ongoing studies, an assessment of the impact that the HEU to LEU fuel conversion has on the nuclear heat generation rates in regions of the HFIR cold source system and its moderator vessel was performed and is documented in this report. Silicon production rates in the coldmore » source aluminum regions and few-group neutron fluxes in the cold source moderator were also estimated. Neutronics calculations were performed with the Monte Carlo N-Particle code to determine the nuclear heat generation rates in regions of the HFIR cold source and its vessel for the HEU core operating at a full reactor power (FP) of 85 MW(t) and the reference LEU core operating at an FP of 100 MW(t). Calculations were performed with beginning-of-cycle (BOC) and end-of-cycle (EOC) conditions to bound typical irradiation conditions. Average specific BOC heat generation rates of 12.76 and 12.92 W/g, respectively, were calculated for the hemispherical region of the cold source liquid hydrogen (LH2) for the HEU and LEU cores, and EOC heat generation rates of 13.25 and 12.86 W/g, respectively, were calculated for the HEU and LEU cores. Thus, the greatest heat generation rates were calculated for the EOC HEU core, and it is concluded that the conversion from HEU to LEU fuel and the resulting increase of FP from 85 MW to 100 MW will not impact the ability of the heat removal equipment to remove the heat deposited in the cold source system. Silicon production rates in the cold source aluminum regions are estimated to be about 12.0% greater at BOC and 2.7% greater at EOC for the LEU core in comparison to the HEU core. Silicon is aluminum s major transmutation product and affects mechanical properties of aluminum including density, neutron irradiation hardening, swelling, and loss of ductility. Because slightly greater quantities of silicon will be produced in the cold source moderator vessel for the LEU core, these effects will be slightly greater for the LEU core than for the HEU core. Three-group (thermal, epithermal, and fast) neutron flux results tallied in the cold source LH2 hemisphere show greater values for the LEU core under both BOC and EOC conditions. The thermal neutron flux in the LH2 hemisphere for the LEU core is about 12.4% greater at BOC and 2.7% greater at EOC than for the HEU core. Therefore, cold neutron scattering will not be adversely affected and the 4 12 neutrons conveyed to the cold neutron guide hall for research applications will be enhanced.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarta, Jose A.; Castiblanco, Luis A

    With cooperation of the International Atomic Energy Agency (IAEA) and the Department of Energy (DOE) of the United States, several calculations and tasks related to the waste disposal of spent MTR fuel enriched nominally to 93% were carried out for the conversion of the IAN-R1 Research Reactor from MTR-HEU fuel to TRIGA-LEU fuel. In order to remove the spent MTR-HEU fuel of the core and store it safely a program was established at the Instituto de Ciencias Nucleares y Energias Alternativas (INEA). This program included training, acquisition of hardware and software, design and construction of a decay pool, transfer ofmore » the spent HEU fuel elements into the decay pool and his final transport to Savannah River in United States. In this paper are presented data of activities calculated for each relevant radionuclide present in spent MTR-HEU fuel elements of the IAN-R1 Research Reactor and the total activity. The total activity calculated takes in consideration contributions of fission, activation and actinides products. The data obtained were the base for shielding calculations for the decay pool concerning the storage of spent MTR-HEU fuel elements and the respective dosimetric evaluations in the transferring operations of fuel elements into the decay pool.« less

  7. HIGHLY ENRICHED URANIUM BLEND DOWN PROGRAM AT THE SAVANNAH RIVER SITE PRESENT AND FUTURE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Magoulas, V; Charles Goergen, C; Ronald Oprea, R

    2008-06-05

    The Department of Energy (DOE) and Tennessee Valley Authority (TVA) entered into an Interagency Agreement to transfer approximately 40 metric tons of highly enriched uranium (HEU) to TVA for conversion to fuel for the Browns Ferry Nuclear Power Plant. Savannah River Site (SRS) inventories included a significant amount of this material, which resulted from processing spent fuel and surplus materials. The HEU is blended with natural uranium (NU) to low enriched uranium (LEU) with a 4.95% 235U isotopic content and shipped as solution to the TVA vendor. The HEU Blend Down Project provided the upgrades needed to achieve the productmore » throughput and purity required and provided loading facilities. The first blending to low enriched uranium (LEU) took place in March 2003 with the initial shipment to the TVA vendor in July 2003. The SRS Shipments have continued on a regular schedule without any major issues for the past 5 years and are due to complete in September 2008. The HEU Blend program is now looking to continue its success by dispositioning an additional approximately 21 MTU of HEU material as part of the SRS Enriched Uranium Disposition Project.« less

  8. Increased risk for and mortality from invasive pneumococcal disease in HIV-exposed but uninfected infants aged <1 year in South Africa, 2009-2013.

    PubMed

    von Mollendorf, Claire; von Gottberg, Anne; Tempia, Stefano; Meiring, Susan; de Gouveia, Linda; Quan, Vanessa; Lengana, Sarona; Avenant, Theunis; du Plessis, Nicolette; Eley, Brian; Finlayson, Heather; Reubenson, Gary; Moshe, Mamokgethi; O'Brien, Katherine L; Klugman, Keith P; Whitney, Cynthia G; Cohen, Cheryl

    2015-05-01

    High antenatal human immunodeficiency virus (HIV) seroprevalence rates (∼ 30%) with low perinatal HIV transmission rates (2.5%), due to HIV prevention of mother-to-child transmission program improvements in South Africa, has resulted in increasing numbers of HIV-exposed but uninfected (HEU) children. We aimed to describe the epidemiology of invasive pneumococcal disease (IPD) in HEU infants. We conducted a cross-sectional study of infants aged <1 year with IPD enrolled in a national, laboratory-based surveillance program for incidence estimations. Incidence was reported for 2 time points, 2009 and 2013. At enhanced sites we collected additional data including HIV status and in-hospital outcome. We identified 2099 IPD cases in infants from 2009 to 2013 from all sites. In infants from enhanced sites (n = 1015), 92% had known HIV exposure status and 86% had known outcomes. IPD incidence was highest in HIV-infected infants, ranging from 272 to 654 per 100,000 population between time points (2013 and 2009), followed by HEU (33-88 per 100,000) and HIV-unexposed and uninfected (HUU) infants (18-28 per 100,000). The case-fatality rate in HEU infants (29% [74/253]) was intermediate between HUU (25% [94/377]) and HIV-infected infants (34% [81/242]). When restricted to infants <6 months of age, HEU infants (37% [59/175]) were at significantly higher risk of dying than HUU infants (32% [51/228]; adjusted relative risk ratio, 1.76 [95% confidence interval, 1.09-2.85]). HEU infants are at increased risk of IPD and mortality from IPD compared with HUU children, especially as young infants. HEU infants, whose numbers will likely continue to increase, should be prioritized for interventions such as pneumococcal vaccination along with HIV-infected infants and children. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. Why is weapons grade plutonium more hazardous to work with than highly enriched uranium?

    DOE PAGES

    Cournoyer, Michael E.; Costigan, Stephen A.; Schake, Bradley S.

    2015-08-01

    Highly Enriched Uranium and Weapons grade plutonium have assumed positions of dominant importance among the actinide elements because of their successful uses as explosive ingredients in nuclear weapons and the place they hold as key materials in the development of industrial use of nuclear power. While most chemists are familiar with the practical interest concerning HEU and WG Pu, fewer know the subtleties among their hazards. In this study, a primer is provided regarding the hazards associated with working with HEU and WG Pu metals and oxides. The care that must be taken to safely handle these materials is emphasizedmore » and the extent of the hazards is described. The controls needed to work with HEU and WG Pu metals and oxides are differentiated. Given the choice, one would rather work with HEU metal and oxides than WG Pu metal and oxides.« less

  10. Why is weapons grade plutonium more hazardous to work with than highly enriched uranium?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cournoyer, Michael E.; Costigan, Stephen A.; Schake, Bradley S.

    Highly Enriched Uranium and Weapons grade plutonium have assumed positions of dominant importance among the actinide elements because of their successful uses as explosive ingredients in nuclear weapons and the place they hold as key materials in the development of industrial use of nuclear power. While most chemists are familiar with the practical interest concerning HEU and WG Pu, fewer know the subtleties among their hazards. In this study, a primer is provided regarding the hazards associated with working with HEU and WG Pu metals and oxides. The care that must be taken to safely handle these materials is emphasizedmore » and the extent of the hazards is described. The controls needed to work with HEU and WG Pu metals and oxides are differentiated. Given the choice, one would rather work with HEU metal and oxides than WG Pu metal and oxides.« less

  11. Initial Neutronics Analyses for HEU to LEU Fuel Conversion of the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kontogeorgakos, D.; Derstine, K.; Wright, A.

    2013-06-01

    The purpose of the TREAT reactor is to generate large transient neutron pulses in test samples without over-heating the core to simulate fuel assembly accident conditions. The power transients in the present HEU core are inherently self-limiting such that the core prevents itself from overheating even in the event of a reactivity insertion accident. The objective of this study was to support the assessment of the feasibility of the TREAT core conversion based on the present reactor performance metrics and the technical specifications of the HEU core. The LEU fuel assembly studied had the same overall design, materials (UO 2more » particles finely dispersed in graphite) and impurities content as the HEU fuel assembly. The Monte Carlo N–Particle code (MCNP) and the point kinetics code TREKIN were used in the analyses.« less

  12. Romania: Brand-New Engineering Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ken Allen; Lucian Biro; Nicolae Zamfir

    The HEU spent nuclear fuel transport from Romania was a pilot project in the framework of the Russian Research Reactor Fuel Return Program (RRRFR), being the first fully certified spent nuclear fuel shipment by air. The successful implementation of the Romanian shipment also brought various new technology in the program, further used by other participating countries. Until 2009, the RRRFR program repatriated to the Russian Federation HEU spent nuclear fuel of Russian origin from many countries, like Uzbekistan, Czech Republic, Latvia, Hungary, Kazakhstan and Bulgaria. The means of transport used were various; from specialized TK-5 train for the carriage ofmore » Russian TUK-19 transport casks, to platform trains for 20 ft freight ISO containers carrying Czech Skoda VPVR/M casks; from river barge on the Danube, to vessel on the Mediterranean Sea and Atlantic Ocean. Initially, in 2005, the transport plan of the HEU spent nuclear fuel from the National Institute for R&D in Nuclear Physics and Nuclear Engineering 'Horia Hulubei' in Magurele, Romania considered a similar scheme, using the specialized TK-5 train transiting Ukraine to the destination point in the Russian Federation, or, as an alternative, using the means and route of the spent nuclear fuel periodically shipped from the Bulgarian nuclear power plant Kosloduy (by barge on the Danube, and by train through Ukraine to the Russian Federation). Due to impossibility to reach an agreement in due time with the transit country, in February 2007 the US, Russian and Romanian project partners decided to adopt the air shipment of the spent nuclear fuel as prime option, eliminating the need for agreements with any transit countries. By this time the spent nuclear fuel inspections were completed, proving the compliance of the burn-up parameters with the international requirements for air shipments of radioactive materials. The short air route avoiding overflying of any other countries except the country of origin and the country of destination also contributed to the decision making in this issue. The efficient project management and cooperation between the three countries (Russia, Romania and USA) made possible, after two and a half years of preparation work, for the first fully certified spent nuclear fuel air shipment to take place on 29th of June 2009, from Romanian airport 'Henri Coanda' to the Russian airport 'Koltsovo' near Yekaterinburg. One day before that, after a record period of 3 weeks of preparation, another HEU cargo was shipped by air from Romanian Institute for Nuclear Research in Pitesti to Russia, containing fresh pellets and therefore making Romania the third HEU-free country in the RRRFR program.« less

  13. Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamel, Michael C.; Polack, J. Kyle; Ruch, Marc L.

    The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to amore » possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.« less

  14. Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification

    DOE PAGES

    Hamel, Michael C.; Polack, J. Kyle; Ruch, Marc L.; ...

    2017-08-11

    The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to amore » possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.« less

  15. ATR LEU Fuel and Burnable Absorber Neutronics Performance Optimization by Fuel Meat Thickness Variation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G. S. Chang

    2007-09-01

    The Advanced Test Reactor (ATR) is a high power density and high neutron flux research reactor operating in the United States. Powered with highly enriched uranium (HEU), the ATR has a maximum thermal power rating of 250 MWth. Because of the large test volumes located in high flux areas, the ATR is an ideal candidate for assessing the feasibility of converting an HEU driven reactor to a low-enriched core. The present work investigates the necessary modifications and evaluates the subsequent operating effects of this conversion. A detailed plate-by-plate MCNP ATR 1/8th core model was developed and validated for a fuelmore » cycle burnup comparison analysis. Using the current HEU U 235 enrichment of 93.0 % as a baseline, an analysis can be performed to determine the low-enriched uranium (LEU) density and U-235 enrichment required in the fuel meat to yield an equivalent K-eff between the HEU core and the LEU core versus effective full power days (EFPD). The MCNP ATR 1/8th core model will be used to optimize the U-235 loading in the LEU core, such that the differences in K-eff and heat flux profile between the HEU and LEU core can be minimized. The depletion methodology MCWO was used to calculate K-eff versus EFPDs in this paper. The MCWO-calculated results for the LEU cases with foil (U-10Mo) types demonstrated adequate excess reactivity such that the K-eff versus EFPDs plot is similar to the reference ATR HEU case. Each HEU fuel element contains 19 fuel plates with a fuel meat thickness of 0.508 mm. In this work, the proposed LEU (U-10Mo) core conversion case with a nominal fuel meat thickness of 0.508 mm and the same U-235 enrichment (15.5 wt%) can be used to optimize the radial heat flux profile by varying the fuel plate thickness from 0.254 to 0.457 mm at the inner 4 fuel plates (1-4) and outer 4 fuel plates (16-19). In addition, a 0.7g of burnable absorber Boron-10 was added in the inner and outer plates to reduce the initial excess reactivity, and the inner/outer heat flux more effectively. The optimized LEU relative radial fission heat flux profile is bounded by the reference ATR HEU case. However, to demonstrate that the LEU core fuel cycle performance can meet the Updated Final Safety Analysis Report (UFSAR) safety requirements, additional studies will be necessary to evaluate and compare safety parameters such as void reactivity and Doppler coefficients, control components worth (outer shim control cylinders, safety rods and regulating rod), and shutdown margins between the HEU and LEU cores.« less

  16. In Utero Exposure to Antiretroviral Drugs: Effect on Birth Weight and Growth Among HIV-Exposed Uninfected Children in Brazil

    PubMed Central

    Hofer, Cristina Barroso; Keiser, Olivia; Zwahlen, Marcel; Lustosa, Carla Sepulveda; CisneFrota, Ana Cristina; de Oliveira, Ricardo Hugo; Abreu, Thalita F; Carvalho, Alice Weber; Araujo, Lucia Evangelista; Egger, Matthias

    2015-01-01

    Context There are concerns about the effects of in utero exposure to antiretroviral drugs (ARVs) on the development of HIV exposed but uninfected (HEU) children. Objectives To evaluate whether in utero exposure to ARVs is associated with lower birth weight/height and reduced growth during the first two years of life. Design Cohort study of HEU infants. Setting Tertiary children's hospital in Rio de Janeiro, Brazil. Study population HEU infants born 1996-2010. Main outcome measures Weight measured by mechanical scale, height measured by measuring board. Z-scores for weight-for-age (WAZ), length-for-age (LAZ) and weight-for-length (WLZ) were calculated. We modeled trajectories by mixed-effects models and adjusted for mother's age, CD4 cell count, viral load, year of birth and family income. Results A total of 588 HEU infants were included of whom 155 (26%) were not exposed to ARVs, 114 (19%) were exposed early (first trimester) and 319 (54%) later. WAZ were lower among infants exposed early compared to infants exposed later: adjusted differences were −0.52 (95% CI −0.99 to −0.04, P=0.02) at birth and −0.22 (95% CI −0.47 to 0.04, P=0.10) during follow-up. LAZ were lower during follow-up: −0.35 (95% CI −0.63 to −0.08, P=0.01). There were no differences in WLZ scores. Z-scores of infants exposed late during pregnancy were similar to unexposed infants. Conclusions In HEU children early exposure to ARVs was associated with lower WAZ at birth and lower LAZ up to 2 years of life. Growth of HEU children needs to be monitored closely. PMID:26741583

  17. Development assessment of HIV exposed children aged 6-18 months: a cohort study from North India.

    PubMed

    Rajan, Remya; Seth, Anju; Mukherjee, Sharmila B; Chandra, Jagdish

    2017-11-01

    HIV exposed children are vulnerable to developmental delay irrespective of their HIV status due to combined effect of risk factors like poverty, prenatal drug exposure, stress and chronic illness in family and malnutrition. This cohort study assessed the development of 50 HIV exposed children aged 6-18 months at a Pediatric Centre of Excellence in HIV care in India. The development was assessed using Development Assessment Scale for Indian Infants (DASII) at enrolment, 3 and 6 months later. The development quotient (DQ) scores and proportion of children with developmental delay (DQ ≤ 70) were compared among two sub-groups, HIV infected (HI) and HIV exposed uninfected (HEU) children. The various social and clinical factors affecting development were studied by univariate and multivariate analysis. Prevalence of developmental delay was 2.4% in the HEU (n = 41), and 33.3% in HI (n = 9). The DQ of HI was significantly lower than that of HEU at all three assessments. The DQ of HI were also significantly lower compared to the HEU at ages 12.1-18 months (83.37 ± 20.73 vs 94.68 ± 5.13, p = 0.005) and 18.1-24 months (84.55 ± 15.35 vs 94.63 ± 5.86, p = 0.006) respectively. The development of HEU was adversely affected by lower socioeconomic status and presence of wasting. In addition, development of HI was also adversely influenced by presence of stunting and opportunistic infections, advanced disease stage and shorter ART duration. We conclude that with optimum care, HEU can have a normal development, while a considerable proportion of HI may continue to have delayed development.

  18. Leo Szilard Lectureship Award Talk: Controlling and eliminating nuclear-weapon materials

    NASA Astrophysics Data System (ADS)

    von Hippel, Frank

    2010-02-01

    Fissile material -- in practice plutonium and highly enriched uranium (HEU) -- is the essential ingredient in nuclear weapons. Controlling and eliminating fissile material and the means of its production is therefore the common denominator for nuclear disarmament, nuclear non-proliferation and the prevention of nuclear terrorism. From a fundamentalist anti-nuclear-weapon perspective, the less fissile material there is and the fewer locations where it can be found, the safer a world we will have. A comprehensive fissile-material policy therefore would have the following elements: *Consolidation of all nuclear-weapon-usable materials at a minimum number of high-security sites; *A verified ban on the production of HEU and plutonium for weapons; *Minimization of non-weapon uses of HEU and plutonium; and *Elimination of all excess stocks of plutonium and HEU. There is activity on all these fronts but it is not comprehensive and not all aspects are being pursued vigorously or competently. It is therefore worthwhile to review the situation. )

  19. 2007 international meeting on Reduced Enrichment for Research and Test Reactors (RERTR). Abstracts and available papers presented at the meeting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2008-07-15

    The Meeting papers discuss research and test reactor fuel performance, manufacturing and testing. Some of the main topics are: conversion from HEU to LEU in different reactors and corresponding problems and activities; flux performance and core lifetime analysis with HEU and LEU fuels; physics and safety characteristics; measurement of gamma field parameters in core with LEU fuel; nondestructive analysis of RERTR fuel; thermal hydraulic analysis; fuel interactions; transient analyses and thermal hydraulics for HEU and LEU cores; microstructure research reactor fuels; post irradiation analysis and performance; computer codes and other related problems.

  20. The Feasibility of Ending HEU Fuel Use in the U.S. Navy

    DOE PAGES

    Philippe, Sebastian; von Hippel, Frank

    2016-11-01

    We report that since September 11, 2001, the U.S. government has sought to remove weapons-useable highly enriched uranium (HEU) containing 20 percent or more uranium-235 from as many locations as possible because of concerns about the possibility of nuclear terrorism.

  1. Prompt Neutron Time Decay in Single HEU and DU Metal Annular Storage Castings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pena, Kirsten E; McConchie, Seth M; Mihalczo, John T

    2010-01-01

    Previous measurements of highly enriched uranium (HEU) storage castings performed by Oak Ridge National Laboratory (ORNL) at the Y-12 National Security Complex showed a prompt neutron time decay that is not exponential. These measurements showed that multiple time constants originating from multiplication, time-of-flight, scattering in the assembly and room return could be associated with this prompt neutron decay. In this work, the contribution not associated with neutron multiplication was investigated via measurements with a depleted uranium (DU) casting. The measurements at ORNL used an annular (5.0-in OD, 3.5-in ID, 6.0-in H) DU casting with a time-tagged 252Cf source, centered verticallymore » on the axis, and four closely coupled 1 1 6-in.-long plastic scintillators with -in.- thick lead shielding adjacent to the outer surface of the casting. This setup was identical to the configuration used in the previously performed measurements with HEU castings at Y-12. The time correlation between fission events and detections in the plastic scintillators was measured, as well as the time distribution of coincidences between multiple detectors within a 512-ns time window. The measurement results were then compared to MCNP-PoliMi calculations and the previous HEU measurements. Time constants from decay fits to the HEU and DU data were compared to characterize the contributions resulting from multiplication, time-of-flight, and scattering.« less

  2. ATR LEU fuel and burnable absorber neutronics performance optimization by fuel meat thickness variation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, G.S.

    2008-07-15

    The Advanced Test Reactor (ATR) is a high power density and high neutron flux research reactor operating in the United States. Powered with highly enriched uranium (HEU), the ATR has a maximum thermal power rating of 250 MWth. Because of the large test volumes located in high flux areas, the ATR is an ideal candidate for assessing the feasibility of converting an HEU driven reactor to a low-enriched core. The present work investigates the necessary modifications and evaluates the subsequent operating effects of this conversion. A detailed plate-by-plate MCNP ATR 1/8th core model was developed and validated for a fuelmore » cycle burnup comparison analysis. Using the current HEU U-235 enrichment of 93.0 % as a baseline, an analysis can be performed to determine the low-enriched uranium (LEU) density and U-235 enrichment required in the fuel meat to yield an equivalent K-eff between the HEU core th and the LEU core versus effective full power days (EFPD). The MCNP ATR 1/8th core model will be used to optimize the U-235 loading in the LEU core, such that the differences in K-eff and heat flux profile between the HEU and LEU core can be minimized. The depletion methodology MCWO was used to calculate K-eff versus EFPDs in this paper. The MCWO-calculated results for the LEU cases with foil (U-10Mo) types demonstrated adequate excess reactivity such that the K-eff versus EFPDs plot is similar to the reference ATR HEU case. Each HEU fuel element contains 19 fuel plates with a fuel meat thickness of 0.508 mm. In this work, the proposed LEU (U-10Mo) core conversion case with a nominal fuel meat thickness of 0.381 mm and the same U-235 enrichment (19.7 wt%) can be used to optimize the radial heat flux profile by varying the fuel meat thickness from 0.191 mm (7.5 mil) to 0.343 mm (13.5 mil) at the inner 4 fuel plates (1-4) and outer 4 fuel plates (16-19). In addition, 0.8g of a burnable absorber, Boron-10, was added in the inner and outer plates to reduce the initial excess reactivity, and the inner/outer heat flux more effectively. The optimized LEU relative radial fission heat flux profile is bounded by the reference ATR HEU case. However, to demonstrate that the LEU core fuel cycle performance can meet the Updated Final Safety Analysis Report (UFSAR) safety requirements, additional studies will be necessary to evaluate and compare safety parameters such as void reactivity and Doppler coefficients, control components worth (outer shim control cylinders, safety rods and regulating rod), and shutdown margins between the HEU and LEU cores. (author)« less

  3. Fracture risk by HIV infection status in perinatally HIV-exposed children.

    PubMed

    Siberry, George K; Li, Hong; Jacobson, Denise

    2012-03-01

    The objective of this study was to examine the incidence of fractures in HIV-infected children and comparable HIV-exposed, uninfected (HEU) children in a multicenter, prospective cohort study (PACTG 219/219C) in the United States. The main outcome was first fracture during the risk period. Nine fractures occurred in 7 of 1326 HIV-infected and 2 of 649 HEU children, corresponding to incidence rates of 1.2 per 1000 person-years and 1.1 per 1000 person-years, respectively. The incidence rate ratio was 1.1 (95% CI 0.2, 5.5). There was no evidence of a substantially increased risk of fracture in HIV-infected compared to HEU children.

  4. Intestinal Integrity Biomarkers in Early Antiretroviral-Treated Perinatally HIV-1-Infected Infants.

    PubMed

    Koay, Wei Li A; Lindsey, Jane C; Uprety, Priyanka; Bwakura-Dangarembizi, Mutsa; Weinberg, Adriana; Levin, Myron J; Persaud, Deborah

    2018-05-12

    Biomarkers of intestinal integrity (intestinal fatty acid binding protein (iFABP) and zonulin), were compared in early antiretroviral-treated, HIV-1-infected (HIV+; n=56) African infants and HIV-exposed but uninfected (HEU; n=53) controls. Despite heightened inflammation and immune activation in HIV+ infants, iFABP and zonulin levels at three months of age were not different from those in HEU infants, and largely not correlated with inflammatory and immune activation biomarkers. However, zonulin levels increased, and became significantly higher in HIV+ compared to HEU infants by five months of age despite ART-suppression. These findings have implications for intestinal integrity biomarker profiling in perinatal HIV-1 infection.

  5. 75 FR 4493 - Natural Resources Defense Council; Denial of Petition for Rulemaking

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-28

    ... NRC continues to license the civilian use of HEU to fuel seven existing research and test reactors... predicts that the three HEU-fueled TRIGA-type research reactors at Oregon State University, the University...) is scheduled for conversion to LEU but notes that the newer and larger LEU-fueled TRIGA facility at...

  6. The Role of the Geographic Combatant Commander in Counterproliferation of Nuclear Weapons

    DTIC Science & Technology

    2007-04-05

    nuclear yield is beyond the scope of this paper; however, this value is above the 20% threshold of HEU meaning that at a minimum HEU is required for... introversion has created an environment where communication and cooperation is almost impossible. This inability to cooperate goes beyond relations between

  7. Research Reactor Preparations for the Air Shipment of Highly Enriched Uranium from Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. J. Allen; I. Bolshinsky; L. L. Biro

    2010-03-01

    In June 2009 two air shipments transported both unirradiated (fresh) and irradiated (spent) Russian-origin highly enriched uranium (HEU) nuclear fuel from two research reactors in Romania to the Russian Federation for conversion to low enriched uranium. The Institute for Nuclear Research at Pitesti (SCN Pitesti) shipped 30.1 kg of HEU fresh fuel pellets to Dimitrovgrad, Russia and the Horia Hulubei National Institute of Physics and Nuclear Engineering (IFIN-HH) shipped 23.7 kilograms of HEU spent fuel assemblies from the VVR S research reactor at Magurele, Romania, to Chelyabinsk, Russia. Both HEU shipments were coordinated by the Russian Research Reactor Fuel Returnmore » Program (RRRFR) as part of the U.S. Department of Energy Global Threat Reduction Initiative (GTRI), were managed in Romania by the National Commission for Nuclear Activities Control (CNCAN), and were conducted in cooperation with the Russian Federation State Corporation Rosatom and the International Atomic Energy Agency. Both shipments were transported by truck to and from respective commercial airports in Romania and the Russian Federation and stored at secure nuclear facilities in Russia until the material is converted into low enriched uranium. These shipments resulted in Romania becoming the 3rd country under the RRRFR program and the 14th country under the GTRI program to remove all HEU. This paper describes the research reactor preparations and license approvals that were necessary to safely and securely complete these air shipments of nuclear fuel.« less

  8. Undervaccination of Perinatally HIV-Infected and HIV-Exposed Uninfected Children in Latin America and the Caribbean

    PubMed Central

    Succi, Regina C. M.; Krauss, Margot R.; Harris, D. Robert; Machado, Daisy M.; de Moraes-Pinto, Maria Isabel; Mussi-Pinhata, Marisa M.; Ruz, Noris Pavia; Pierre, Russell B.; Kolevic, Lenka; Joao, Esau; Foradori, Irene; Hazra, Rohan

    2013-01-01

    Background Perinatally HIV-infected children (PHIV) may be at risk of undervaccination. Vaccination coverage rates among PHIV and HIV-exposed uninfected children (HEU) in Latin America and the Caribbean were compared. Methods All PHIV and HEU children born from 2002–2007 that were enrolled in a multi-site observational study conducted in Latin America and the Caribbean were included in this analysis. Children were classified as up to date (UTD) if they had received the recommended number of doses of each vaccine at the appropriate intervals by 12 and 24 months of age. Fisher’s exact test was used to analyze the data. Covariates potentially associated with a child’s HIV status were considered in multivariable logistic regression modeling. Results Of 1156 eligible children, 768 (66.4%) were HEU and 388 (33.6%) were PHIV. HEU children were significantly (p<0.01) more likely to be UTD by 12 and 24 months of age for all vaccines examined. Statistically significant differences persisted when the analyses were limited to children enrolled prior to 12 months of age. Controlling for birth weight, sex, primary caregiver education and any use of tobacco, alcohol or illegal drugs during pregnancy did not contribute significantly to the logistic regression models. Conclusions PHIV children were significantly less likely than HEU children to be UTD for their childhood vaccinations at 12 and 24 months of age, even when limited to children enrolled before 12 months of age. Strategies to increase vaccination rates in PHIV are needed. PMID:23860480

  9. 10 CFR 50.64 - Limitations on the use of highly enriched uranium (HEU) in domestic non-power reactors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... domestic non-power reactors. 50.64 Section 50.64 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF... Permits § 50.64 Limitations on the use of highly enriched uranium (HEU) in domestic non-power reactors. (a) Applicability. The requirements of this section apply to all non-power reactors. (b) Requirements. (1) The...

  10. 10 CFR 50.64 - Limitations on the use of highly enriched uranium (HEU) in domestic non-power reactors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... domestic non-power reactors. 50.64 Section 50.64 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF... Permits § 50.64 Limitations on the use of highly enriched uranium (HEU) in domestic non-power reactors. (a) Applicability. The requirements of this section apply to all non-power reactors. (b) Requirements. (1) The...

  11. Analysis of Accidents at the Pakistan Research Reactor-1 Using Proposed Mixed-Fuel (HEU and LEU) Core

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bokhari, Ishtiaq H.

    2004-12-15

    The Pakistan Research Reactor-1 (PARR-1) was converted from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel in 1991. The reactor is running successfully, with an upgraded power level of 10 MW. To save money on the purchase of costly fresh LEU fuel elements, the use of less burnt HEU spent fuel elements along with the present LEU fuel elements is being considered. The proposal calls for the HEU fuel elements to be placed near the thermal column to gain the required excess reactivity. In the present study the safety analysis of a proposed mixed-fuel core has been carried outmore » at a calculated steady-state power level of 9.8 MW. Standard computer codes and correlations were employed to compute various parameters. Initiating events in reactivity-induced accidents involve various modes of reactivity insertion, namely, start-up accident, accidental drop of a fuel element on the core, flooding of a beam tube with water, and removal of an in-pile experiment during reactor operation. For each of these transients, time histories of reactor power, energy released, temperature, and reactivity were determined.« less

  12. Neutronics and Thermal Hydraulics Study for Using a Low-Enriched Uranium Core in the Advanced Test Reactor -- 2008 Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G. S. Chang; M. A. Lillo; R. G. Ambrosek

    2008-06-01

    The Advanced Test Reactor (ATR) is a high power density and high neutron flux research reactor operating in the United States. Powered with highly enriched uranium (HEU), the ATR has a maximum thermal power rating of 250 MWth. Because of the large test volumes located in high flux areas, the ATR is an ideal candidate for assessing the feasibility of converting an HEU driven reactor to a low-enriched core. The present work investigates the necessary modifications and evaluates the subsequent operating effects of this conversion. A detailed plate-by-plate MCNP ATR 1/8th core model was developed and validated for a fuelmore » cycle burnup comparison analysis. Using the current HEU U 235 enrichment of 93.0 % as a baseline, an analysis was performed to determine the low-enriched uranium (LEU) density and U-235 enrichment required in the fuel meat to yield an equivalent K-eff versus effective full power days (EFPDs) between the HEU and the LEU cores. The MCNP ATR 1/8th core model was used to optimize the U 235 loading in the LEU core, such that the differences in K-eff and heat flux profiles between the HEU and LEU cores were minimized. The depletion methodology MCWO was used to calculate K-eff versus EFPDs in this paper. The MCWO-calculated results for the LEU demonstrated adequate excess reactivity such that the K-eff versus EFPDs plot is similar to the ATR reference HEU case study. Each HEU fuel element contains 19 fuel plates with a fuel meat thickness of 0.508 mm (20 mil). In this work, the proposed LEU (U-10Mo) core conversion case with nominal fuel meat thickness of 0.330 mm (13 mil) and U-235 enrichment of 19.7 wt% is used to optimize the radial heat flux profile by varying the fuel meat thickness from 0.191 mm (7.0 mil) to 0.330 mm (13.0 mil) at the inner 4 fuel plates (1-4) and outer 4 fuel plates (16-19). A 0.8g of Boron-10, a burnable absorber, was added in the inner and outer plates to reduce the initial excess reactivity, and the peak to average ratio of the inner/outer heat flux more effectively. Because the B-10 (n,a) reaction will produce Helium-4 (He-4), which might degrade the LEU foil type fuel performance, an alternative absorber option is proposed. The proposed LEU case study will have 6.918 g of Cadmium (Cd) mixed with the LEU at the inner 4 fuel plates (1-4) and outer 4 fuel plates (16-19) as a burnable absorber to achieve peak to average ratios similar to those for the ATR reference HEU case study.« less

  13. Reducing The Nuclear Danger

    DTIC Science & Technology

    1995-10-01

    off convention • Eliminate the civil use of HEU (includes RERTR ) • Reduce stockpiles of civil HEU and plutonium • Promote alternatives to the...these countries. ANL supports the Department’s Reduced Enrichment for Research and Test Reactor ( RERTR ) Program by providing the technical means to...scientists and engineers at 60 institutes in Russia, Ukraine, Kazakhstan and Belarus. The United States and Russia have agreed to pursue a joint RERTR

  14. Annual Review of Research under the Joint Services Electronics Program,

    DTIC Science & Technology

    1980-10-01

    have no Now let, hyu : (ulul) i---- (yl,y2). Using the summing common factors. More precisely, since J serves as the e ua group of units in our theory...these conditions imply node equations it is easy to see that that any common factors of p and c must lie in J. hyu " K(heu - 1) and heu - I-hy u IV

  15. Calibration of the Lawrence Livermore National Laboratory Passive-Active Neutron Drum Shuffler for Measurement of Highly Enriched Uranium in Oxides within DOE-STD-3013-2000 Containers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mount, M E; O'Connell, W J

    2005-06-03

    Lawrence Livermore National Laboratory (LLNL) uses the LLNL passive-active neutron drum (PAN) shuffler (Canberra Model JCC-92) for accountability measurement of highly enriched uranium (HEU) oxide and HEU in mixed uranium-plutonium (U-Pu) oxide. In June 2002, at the 43rd Annual Meeting of the Institute of Nuclear Material Management, LLNL reported on an extensive effort to calibrate this shuffler, based on standards measurements and extensive simulations, for HEU oxides and mixed U-Pu oxides in thin-walled primary and secondary containers. In August 2002, LLNL began to also use DOE-STD-3013-2000 containers for HEU oxide and mixed U-Pu oxide. These DOE-STD-3013-2000 containers are comprised ofmore » a stainless steel convenience can enclosed in welded stainless steel primary and secondary containers. Compared to the double thin-walled containers, the DOE-STD-3013-2000 containers have substantially thicker walls, and the density of materials in these containers was found to extend over a greater range (1.35 g/cm{sup 3} to 4.62 g/cm{sup 3}) than foreseen for the double thin-walled containers. Further, the DOE-STD-3013-2000 Standard allows for oxides containing at least 30 wt% Pu plus U whereas the calibration algorithms for thin-walled containers were derived for virtually pure HEU or mixed U-Pu oxides. An initial series of Monte Carlo simulations of the PAN shuffler response to given quantities of HEU oxide and mixed U-Pu oxide in DOE-STD-3013-2000 containers was generated and compared with the response predicted by the calibration algorithms for thin-walled containers. Results showed a decrease on the order of 10% in the count rate, and hence a decrease in the calculated U mass for measured unknowns, with some varying trends versus U mass. Therefore a decision was made to develop a calibration algorithm for the PAN shuffler unique to the DOE-STD-3013-2000 container. This paper describes that effort and selected unknown item measurement results.« less

  16. Brain Imaging and Neurodevelopment in HIV-uninfected Thai Children Born to HIV-infected Mothers.

    PubMed

    Jahanshad, Neda; Couture, Marie-Claude; Prasitsuebsai, Wasana; Nir, Talia M; Aurpibul, Linda; Thompson, Paul M; Pruksakaew, Kanchana; Lerdlum, Sukalaya; Visrutaratna, Pannee; Catella, Stephanie; Desai, Akash; Kerr, Stephen J; Puthanakit, Thanyawee; Paul, Robert; Ananworanich, Jintanat; Valcour, Victor G

    2015-09-01

    Perinatal use of combination antiretroviral therapy dramatically reduces vertical (mother-to-child) transmission of HIV but has led to a growing population of children with perinatal HIV-exposure but uninfected (HEU). HIV can cause neurological injury among children born with infection, but the neuroanatomical and developmental effects in HEU children are poorly understood. We used structural magnetic resonance imaging with diffusion tensor imaging to compare brain anatomy between 30 HEU and 33 age-matched HIV-unexposed and uninfected (HUU) children from Thailand. Maps of brain volume and microstructural anatomy were compared across groups; associations were tested between neuroimaging measures and concurrent neuropsychological test performance. Mean (standard deviation) age of children was 10.3 (2.8) years, and 58% were male. All were enrolled in school and lived with family members. Intelligence quotient (IQ) did not differ between groups. Caretaker education levels did not differ, but income was higher for HUU (P < 0.001). We did not detect group differences in brain volume or diffusion tensor imaging metrics, after controlling for sociodemographic factors. The mean (95% confidence interval) fractional anisotropy in the corpus callosum was 0.375 (0.368-0.381) in HEU compared with 0.370 (0.364-0.375) in HUU. Higher fractional anisotropy and lower mean diffusivity were each associated with higher IQ scores in analyses with both groups combined. No differences in neuroanatomical or brain integrity measures were detectable in HEU children compared with age-matched and sex-matched controls (HUU children). Expected associations between brain integrity measures and IQ scores were identified suggesting sufficient power to detect subtle associations that were present.

  17. HIV-Exposed Uninfected Infants in Zimbabwe: Insights into Health Outcomes in the Pre-Antiretroviral Therapy Era

    PubMed Central

    Evans, Ceri; Humphrey, Jean H.; Ntozini, Robert; Prendergast, Andrew J.

    2016-01-01

    The ZVITAMBO trial recruited 14,110 mother–infant pairs to a randomized controlled trial of vitamin A between 1997 and 2000, before the availability of antiretroviral therapy for HIV prophylaxis or treatment in Zimbabwe. The HIV status of mothers and infants was well characterized through 1–2 years of follow-up, leading to the largest cohort to date of HIV-exposed uninfected (HEU) infants (n = 3135), with a suitable comparison group of HIV-unexposed infants (n = 9510). Here, we draw on 10 years of published findings from the ZVITAMBO trial. HEU infants had increased morbidity compared to HIV-unexposed infants, with 50% more hospitalizations in the neonatal period and 30% more sick clinic visits during infancy, particularly for skin infections, lower respiratory tract infections, and oral thrush. HEU children had 3.9-fold and 2.0-fold higher mortality than HIV-unexposed children during the first and second years of life, respectively, most commonly due to acute respiratory infections, diarrhea/dysentery, malnutrition, sepsis, and meningitis. Infant morbidity and mortality were strongly related to maternal HIV disease severity, and increased morbidity remained until maternal CD4 counts were >800 cells/μL. HEU infants were more likely to be premature and small-for-gestational age than HIV-unexposed infants, and had more postnatal growth failure. Here, we propose a conceptual framework to explain the increased risk of infectious morbidity, mortality, and growth failure among HEU infants, hypothesizing that immune activation and inflammation are key drivers of both infection susceptibility and growth failure. Future studies should further dissect the causes of infection susceptibility and growth failure and determine the impact of ART and cotrimoxazole on outcomes of this vulnerable group of infants in the current era. PMID:27375613

  18. Cognitive and language outcomes in HIV-uninfected infants exposed to combined antiretroviral therapy in utero and through extended breast-feeding.

    PubMed

    Ngoma, Mary S; Hunter, Jennifer A; Harper, Jessica A; Church, Paige T; Mumba, Scholastica; Chandwe, Mulapati; Côté, Hélène C F; Albert, Arianne Y K; Smith, Mary-Lou; Selemani, Chisomo; Sandstrom, Paul A; Bandenduck, Lucas; Ndlovu, Utsile; Khan, Sara; Roa, Lina; Silverman, Michael S

    2014-07-01

    To determine whether there is a higher risk for cognitive or language delay among HIV-exposed uninfected (HEU) children exposed to cART (zidovudine/lamivudine/lopinavir/ritonavir) in utero and through 1 year of breast-feeding (World health Organization Option B+), compared with the control children born to HIV-uninfected mothers. This is a double cohort study from Lusaka, Zambia. HEU (n = 97) and control (n = 103) children aged 15-36 months were assessed on their early nonverbal problem-solving and language skills using the standardized Capute Scales. A score of less than 85 on the Capute Full-Scale Developmental Quotient (FSDQ) was considered indicative of developmental delay and was the primary outcome of interest. An FSDQ of less than 85 was found in eight (8.3%) of HEU participants and 15 (14.6%) of controls. In univariate logistic regressions, lower income [odds ratio (OR) = 0.93, P = 0.02], older infant age (OR = 1.08, P = 0.03), lower birth weight (OR = 0.16, P < 0.001), and less maternal education (OR = 0.41, P = 0.047) were associated with the probability of FSDQ less than 85, whereas Group (control/HEU) was not (OR = 1.88, P = 0.16). In the multivariable analysis, only lower birth weight (OR = 0.15, P < 0.001) remained associated with FSDQ less than 85. Our study did not support the presence of an adverse effect on cognitive and language development with prolonged antepartum and postpartum cART e/xposure. Larger studies and studies of older HEU children will be required to confirm these reassuring findings.

  19. Irans Nuclear Program: Tehrans Compliance with International Obligations

    DTIC Science & Technology

    2016-04-07

    ratified the nuclear Nonproliferation Treaty (NPT) in 1970. Article III of the treaty requires non-nuclear- weapon states-parties 1 to accept...concern that Tehran is pursuing nuclear weapons . Tehran’s construction of gas centrifuge uranium enrichment facilities is currently the main source...uranium (HEU), which is one of the two types of fissile material used in nuclear weapons . HEU can also be used as fuel in certain types of nuclear

  20. Irans Nuclear Program: Tehrans Compliance with International Obligations

    DTIC Science & Technology

    2016-03-03

    ratified the nuclear Nonproliferation Treaty (NPT) in 1970. Article III of the treaty requires non-nuclear- weapon states-parties 1 to accept...concern that Tehran is pursuing nuclear weapons . Tehran’s construction of gas centrifuge uranium enrichment facilities is currently the main source...uranium (HEU), which is one of the two types of fissile material used in nuclear weapons . HEU can also be used as fuel in certain types of nuclear

  1. Surviving and Thriving-Shifting the Public Health Response to HIV-Exposed Uninfected Children: Report of the 3rd HIV-Exposed Uninfected Child Workshop.

    PubMed

    Slogrove, Amy L; Becquet, Renaud; Chadwick, Ellen G; Côté, Hélène C F; Essajee, Shaffiq; Hazra, Rohan; Leroy, Valériane; Mahy, Mary; Murenga, Maurine; Wambui Mwangi, Jacqueline; Oyiengo, Laura; Rollins, Nigel; Penazzato, Martina; Seage, George R; Serghides, Lena; Vicari, Marissa; Powis, Kathleen M

    2018-01-01

    Great gains were achieved with the introduction of the United Nations' Millennium Development Goals, including improved child survival. Transition to the Sustainable Development Goals (SDGs) focused on surviving, thriving, and transforming, representing an important shift to a broader public health goal, the achievement of which holds the promise of longer-term individual and societal benefits. A similar shift is needed with respect to outcomes for infants born to women living with HIV (WLHIV). Programming to prevent vertical HIV transmission has been successful in increasingly achieving a goal of HIV-free survival for infants born to WLHIV. Unfortunately, HIV-exposed uninfected (HEU) children are not achieving comparable health and developmental outcomes compared with children born to HIV-uninfected women under similar socioeconomic circumstances. The 3rd HEU Child Workshop, held as a satellite session of the International AIDS Society's 9th IAS Conference in Paris in July 2017, provided a venue to discuss HEU child health and development disparities. A summary of the Workshop proceedings follows, providing current scientific findings, emphasizing the gap in systems for long-term monitoring, and highlighting the public health need to establish a strategic plan to better quantify the short and longer-term health and developmental outcomes of HEU children.

  2. Designing and implementing transparency for real time inspection of autonomous robots

    NASA Astrophysics Data System (ADS)

    Theodorou, Andreas; Wortham, Robert H.; Bryson, Joanna J.

    2017-07-01

    The EPSRC's Principles of Robotics advises the implementation of transparency in robotic systems, however research related to AI transparency is in its infancy. This paper introduces the reader of the importance of having transparent inspection of intelligent agents and provides guidance for good practice when developing such agents. By considering and expanding upon other prominent definitions found in literature, we provide a robust definition of transparency as a mechanism to expose the decision-making of a robot. The paper continues by addressing potential design decisions developers need to consider when designing and developing transparent systems. Finally, we describe our new interactive intelligence editor, designed to visualise, develop and debug real-time intelligence.

  3. Some Aspects of the Implementation of the Principle of Transparency in Russian Universities: Research, Experience, Perspectives

    ERIC Educational Resources Information Center

    Egorov, Evgeny Evgenievich; Lebedev?, Tatiana Evgenievna; Bulganina, Svetlana Viktorovna; Vasilyeva, Lyudmila Ivanovna

    2015-01-01

    The aim of this study is to identify achieved successes, existing gaps and possible prospects of implementing the principle of transparency by Russian universities. It was focused upon the information transparency of educational activities from the perspective of legal requirements and interests of applicants and university students. The analysis…

  4. Feeding practices and nutritional status of HIV-exposed and HIV-unexposed infants in the Western Cape

    PubMed Central

    Cornell, Morna; Cotton, Mark F.; Esser, Monika M.

    2016-01-01

    Background Optimal infant- and young child–feeding practices are crucial for nutritional status, growth, development, health and, ultimately, survival. Human breast milk is optimal nutrition for all infants. Complementary food introduced at the correct age is part of optimal feeding practices. In South Africa, widespread access to antiretrovirals and a programme to prevent mother-to-child transmission of HIV have reduced HIV infection in infants and increased the number of HIV-exposed uninfected (HEU) infants. However, little is known about the feeding practices and nutritional status of HEU and HIV-unexposed (HU) infants. Objective To assess the feeding practices and nutritional status of HIV-exposed and HIV-unexposed (HU) infants in the Western Cape. Design Prospective substudy on feeding practices nested in a pilot study investigating the innate immune abnormalities in HEU infants compared to HU infants. The main study commenced at week 2 of life with the nutrition component added from 6 months. Information on children’s dietary intake was obtained at each visit from the caregiver, mainly the mother. Head circumference, weight and length were recorded at each visit. Data were obtained from 6-, 12- and 18-month visits. World Health Organization feeding practice indicators and nutrition indicators were utilised. Setting Tygerberg Academic Hospital, Western Cape. Mothers were recruited from the postnatal wards. Subjects Forty-seven mother–infant pairs, 25 HEU and 22 HU infants, participated in this nutritional substudy. Eight (17%) infants, one HU and seven HEU, were lost to follow-up over the next 12 months. The HEU children were mainly Xhosa (76%) and HU were mainly mixed race (77%). Results The participants were from poor socio-economic backgrounds. In both groups, adherence to breastfeeding recommendations was low with suboptimal dietary diversity. We noted a high rate of sugar- and salt-containing snacks given from a young age. The HU group had poorer anthropometric and nutritional indicators not explained by nutritional factors alone. However, alcohol and tobacco use was much higher amongst the HU mothers. Conclusion Adherence to breastfeeding recommendations was low. Ethnicity and cultural milieu may have influenced feeding choices and growth. Further research is needed to understand possible reasons for the poorer nutritional and anthropometric indicators in the HU group. PMID:29568600

  5. Investigation into the Feasibility of Highly Enriched Uranium Detection by External Neutron Stimulation (Expanded Study)

    DTIC Science & Technology

    2006-05-01

    26 1.10.1 Radiation Isotope Detector Operation ...... 27 1.10.2 HEU Counts in Radioisotope with 1 kg HEU.. 27 1.10.3 Radiation Isotope ...REACTOR GRADE PLUTONIUM ........... 173 10.2 GAMMA EMITTING ISOTOPES IN CARGO MATERIAL ............. 177 10.3 MCNP ANALYSIS OF GAMMA TRANSPORT FROM A...experiment at USNA using a germanium detector .......................... 31 1-13 Counts in the radiation isotope detector versus counting time for 1

  6. Analytical analyses of startup measurements associated with the first use of LEU fuel in Romania`s 14-MW TRIGA reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bretscher, M.M.; Snelgrove, J.L.; Ciocanescu, M.

    1992-12-01

    The 14-MW TRIGA steady state reactor (SSR) is located in Pitesti, Romania. Beginning with an HEU core (10 wt% U), the reactor first went critical in November 1979 but was shut down ten years later because of insufficient excess reactivity. Last November the Institute for Nuclear Research (INR), which operates the SSR, received from the ANL RERTR program a shipment of 125 LEU pins fabricated by General Atomics and of the same geometry as the original fuel but with an enrichment of 19.7% 235U and a loading of 45 wt% U. Using 100 of these pins, four LEU clusters, eachmore » containing a 5 x 5 square array of fuel rods, were assembled. These four LEU clusters replaced the four most highly burned HEU elements in the SSR. The reactor resumed operations last February with a 35-element mixed HEU/LEU core configuration. In preparation for full power operation of the SSR with this mixed HEU/LEU core, a number of measurements were made. These included control rod calibrations, excess reactivity determinations, worths of experiment facilities, reaction rate distributions, and themocouple measurements of fuel temperatures as a function of reactor power. This paper deals with a comparison of some of these measured reactor parameters with corresponding analytical calculations.« less

  7. Impact of HFIR LEU Conversion on Beryllium Reflector Degradation Factors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilas, Dan

    2013-10-01

    An assessment of the impact of low enriched uranium (LEU) conversion on the factors that may cause the degradation of the beryllium reflector is performed for the High Flux Isotope Reactor (HFIR). The computational methods, models, and tools, comparisons with previous work, along with the results obtained are documented and discussed in this report. The report documents the results for the gas and neutronic poison production, and the heating in the beryllium reflector for both the highly enriched uranium (HEU) and LEU HFIR configurations, and discusses the impact that the conversion to LEU may have on these quantities. A time-averagingmore » procedure was developed to calculate the isotopic (gas and poisons) production in reflector. The sensitivity of this approach to different approximations is gauged and documented. The results show that the gas is produced in the beryllium reflector at a total rate of 0.304 g/cycle for the HEU configuration; this rate increases by ~12% for the LEU case. The total tritium production rate in reflector is 0.098 g/cycle for the HEU core and approximately 11% higher for the LEU core. A significant increase (up to ~25%) in the neutronic poisons production in the reflector during the operation cycles is observed for the LEU core, compared to the HEU case, for regions close to the core s horizontal midplane. The poisoning level of the reflector may increase by more than two orders of magnitude during long periods of downtime. The heating rate in the reflector is estimated to be approximately 20% lower for the LEU core than for the HEU core. The decrease is due to a significantly lower contribution of the heating produced by the gamma radiation for the LEU core. Both the isotopic (gas and neutronic poisons) production and the heating rates are spatially non-uniform throughout the beryllium reflector volume. The maximum values typically occur in the removable reflector and close to the midplane.« less

  8. Transparent 3D display for augmented reality

    NASA Astrophysics Data System (ADS)

    Lee, Byoungho; Hong, Jisoo

    2012-11-01

    Two types of transparent three-dimensional display systems applicable for the augmented reality are demonstrated. One of them is a head-mounted-display-type implementation which utilizes the principle of the system adopting the concave floating lens to the virtual mode integral imaging. Such configuration has an advantage in that the threedimensional image can be displayed at sufficiently far distance resolving the accommodation conflict with the real world scene. Incorporating the convex half mirror, which shows a partial transparency, instead of the concave floating lens, makes it possible to implement the transparent three-dimensional display system. The other type is the projection-type implementation, which is more appropriate for the general use than the head-mounted-display-type implementation. Its imaging principle is based on the well-known reflection-type integral imaging. We realize the feature of transparent display by imposing the partial transparency to the array of concave mirror which is used for the screen of reflection-type integral imaging. Two types of configurations, relying on incoherent and coherent light sources, are both possible. For the incoherent configuration, we introduce the concave half mirror array, whereas the coherent one adopts the holographic optical element which replicates the functionality of the lenslet array. Though the projection-type implementation is beneficial than the head-mounted-display in principle, the present status of the technical advance of the spatial light modulator still does not provide the satisfactory visual quality of the displayed three-dimensional image. Hence we expect that the head-mounted-display-type and projection-type implementations will come up in the market in sequence.

  9. Proliferation dangers associated with nuclear medicine: getting weapons-grade uranium out of radiopharmaceutical production.

    PubMed

    Williams, Bill; Ruff, Tilman A

    2007-01-01

    Abolishing the threat of nuclear war requires the outlawing of nuclear weapons and dismantling current nuclear weapon stockpiles, but also depends on eliminating access to fissile material (nuclear weapon fuel). The near-universal use of weapons-grade, highly enriched uranium (HEU) to produce radiopharmaceuticals is a significant proliferation hazard. Health professionals have a strategic opportunity and obligation to progress the elimination of medically-related commerce in HEU, closing one of the most vulnerable pathways to the much-feared 'terrorist bomb'.

  10. Global threat reduction initiative Russian nuclear material removal progress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cummins, Kelly; Bolshinsky, Igor

    2008-07-15

    In December 1999 representatives from the United States, the Russian Federation, and the International Atomic Energy Agency (IAEA) started discussing a program to return to Russia Soviet- or Russian-supplied highly enriched uranium (HEU) fuel stored at the Russian-designed research reactors outside Russia. Trilateral discussions among the United States, Russian Federation, and the International Atomic Energy Agency (IAEA) have identified more than 20 research reactors in 17 countries that have Soviet- or Russian-supplied HEU fuel. The Global Threat Reduction Initiative's Russian Research Reactor Fuel Return Program is an important aspect of the U.S. Government's commitment to cooperate with the other nationsmore » to prevent the proliferation of nuclear weapons and weapons-usable proliferation-attractive nuclear materials. To date, 496 kilograms of Russian-origin HEU have been shipped to Russia from Serbia, Latvia, Libya, Uzbekistan, Romania, Bulgaria, Poland, Germany, and the Czech Republic. The pilot spent fuel shipment from Uzbekistan to Russia was completed in April 2006. (author)« less

  11. Key metrics for HFIR HEU and LEU models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilas, Germina; Betzler, Benjamin R.; Chandler, David

    This report compares key metrics for two fuel design models of the High Flux Isotope Reactor (HFIR). The first model represents the highly enriched uranium (HEU) fuel currently in use at HFIR, and the second model considers a low-enriched uranium (LEU) interim design fuel. Except for the fuel region, the two models are consistent, and both include an experiment loading that is representative of HFIR's current operation. The considered key metrics are the neutron flux at the cold source moderator vessel, the mass of 252Cf produced in the flux trap target region as function of cycle time, the fast neutronmore » flux at locations of interest for material irradiation experiments, and the reactor cycle length. These key metrics are a small subset of the overall HFIR performance and safety metrics. They were defined as a means of capturing data essential for HFIR's primary missions, for use in optimization studies assessing the impact of HFIR's conversion from HEU fuel to different types of LEU fuel designs.« less

  12. Quality of Caregiving is Positively Associated With Neurodevelopment During the First Year of Life Among HIV-Exposed Uninfected Children in Uganda.

    PubMed

    Familiar, Itziar; Collins, Shalean M; Sikorskii, Alla; Ruisenor-Escudero, Horacio; Natamba, Barnabas; Bangirana, Paul; Widen, Elizabeth M; Achidri, Daniel; Achola, Harriet; Onen, Daniel; Boivin, Michael; Young, Sera L

    2018-03-01

    We sought to evaluate whether maternal characteristics and infant developmental milieu were predictive of early cognitive development in HIV-exposed uninfected (HEU) and HIV-unexposed uninfected (HU) infants in Uganda. Longitudinal pregnancy study. Ugandan women (n = 228) were enrolled into the Postnatal Nutrition and Psychosocial Health Outcomes study with a 2:1 HIV-uninfected: infected ratio. Maternal sociodemographic, perceived social support, and depressive symptomatology were assessed. Infant growth and neurocognitive development were assessed at 6 and 12 months of age using Mullen Scales of Early Learning (MSEL). Caldwell Home Observation for Home Environment was used to gauge caregiving quality. Linear mixed-effects models were built to examine the relationships between maternal and infant characteristics with infant MSEL scores by HIV exposure. Two MSEL measures were available for 215 mother-child dyads: 140 infants (65%) were HIV-uninfected (HU), 57 (27%) were HIV-exposed uninfected (HEU) with mothers reporting antiretroviral therapy, and 18 (8%) were HEU with mothers not reporting antiretroviral therapy. HEU had lower MSEL Composite (β = -3.94, P = 0.03) and Gross Motor scores (β = -3.41, P = 0.01) than HU. Home Observation for Home Environment total score was positively associated with MSEL Composite (β = 0.81, P = 0.01), Receptive Language (β = 0.59, P = 0.001), and Expressive Language (β = 0.64, P = 0.01) scores. HIV exposure is associated with lower infant cognitive development scores. Increasing maternal quality of caregiving may improve early cognitive development.

  13. Transition from HEU to LEU fuel in Romania`s 14-MW TRIGA reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bretscher, M.M.; Snelgrove, J.L.

    1991-12-31

    The 14-MW TRIGA steady state reactor (SSR) located in Pitesti, Romania, first went critical in the fall of 1979. Initially, the core configuration for full power operation used 29 fuel clusters each containing a 5 {times} 5 square array of HEU (10 wt%) -- ZrH -- Er (2.8 wt%) fuel-moderator rods (1.295 cm o.d.) clad in Incology. With a total inventory of 35 HEU fuel clusters, burnup considerations required a gradual expansion of the core from 29 to 32 and finally to 35 clusters before the reactor was shut down because of insufficient excess reactivity. At this time each ofmore » the original 29 fuel clusters had an overage {sup 235}U burnup in the range from 50 to 62%. Because of the US policy regarding the export of highly enriched uranium, fresh HEU TRIGA replacement fuel is not available. After a number of safety-related measurements, the SSR is expected to resume full power operation in the near future using a mixed core containing five LEU TRIGA clusters of the same geometry as the original fuel but with fuel-moderator rods containing 45 wt% U (19.7% {sup 235}U enrichment) and 1.1 wt% Er. Rods for 14 additional LEU fuel clusters will be fabricated by General Atomics. In support of the SSR mixed core operation numerous neutronic calculations have been performed. This paper presents some of the results of those calculations.« less

  14. Active interrogation of highly enriched uranium

    NASA Astrophysics Data System (ADS)

    Fairrow, Nannette Lea

    Safeguarding special nuclear material (SNM) in the Department of Energy Complex is vital to the national security of the United States. Active and passive nondestructive assays are used to confirm the presence of SNM in various configurations ranging from waste to nuclear weapons. Confirmation measurements for nuclear weapons are more challenging because the design complicates the detection of a distinct signal for highly enriched uranium. The emphasis of this dissertation was to investigate a new nondestructive assay technique that provides an independent and distinct signal to confirm the presence of highly enriched uranium (HEU). Once completed and tested this assay method could be applied to confirmation measurements of nuclear weapons. The new system uses a 14-MeV neutron source for interrogation and records the arrival time of neutrons between the pulses with a high efficiency detection system. The data is then analyzed by the Feynman reduced variance method. The analysis determined the amount of correlation in the data and provided a unique signature of correlated fission neutrons. Measurements of HEU spheres were conducted at Los Alamos with the new system. Then, Monte Carlo calculations were performed to verify hypothesis made about the behavior of the neutrons in the experiment. Comparisons of calculated counting rates by the Monte Carlo N-Particle Transport Code (MCNP) were made with the experimental data to confirm that the measured response reflected the desired behavior of neutron interactions in the highly enriched uranium. In addition, MCNP calculations of the delayed neutron build-up were compared with the measured data. Based on the results obtained from this dissertation, this measurement method has the potential to be expanded to include mass determinations of highly enriched uranium. Although many safeguards techniques exist for measuring special nuclear material, the number of assays that can be used to confirm HEU in shielded systems is limited. These assays also rely on secondary characteristics of the material to be measured. A review of the nondestructive techniques with potential applications for nuclear weapons confirmatory measurements were evaluated with summaries of the pros and cons involved in implementing the methods at production type facilities.

  15. Missile Defense: European Phased Adaptive Approach Acquisitions Face Synchronization, Transparency, and Accountability Challenges

    DTIC Science & Technology

    2010-12-21

    House of Representatives Subject: Missile Defense: European Phased Adaptive Approach Acquisitions Face Synchronization , Transparency, and...TITLE AND SUBTITLE Missile Defense: European Phased Adaptive Approach Acquisitions Face Synchronization , Transparency, and Accountability...However, we found that DOD has not fully implemented a management process that synchronizes EPAA acquisition activities and ensures transparency and

  16. Body fat distribution in perinatally HIV-infected and HIV-exposed but uninfected children in the era of highly active antiretroviral therapy: outcomes from the Pediatric HIV/AIDS Cohort Study1234

    PubMed Central

    Jacobson, Denise L; Patel, Kunjal; Siberry, George K; Van Dyke, Russell B; DiMeglio, Linda A; Geffner, Mitchell E; Chen, Janet S; McFarland, Elizabeth J; Borkowsky, William; Silio, Margarita; Fielding, Roger A; Siminski, Suzanne; Miller, Tracie L

    2011-01-01

    Background: Associations between abnormal body fat distribution and clinical variables are poorly understood in pediatric HIV disease. Objective: Our objective was to compare total body fat and its distribution in perinatally HIV-infected and HIV-exposed but uninfected (HEU) children and to evaluate associations with clinical variables. Design: In a cross-sectional analysis, children aged 7–16 y in the Pediatric HIV/AIDS Cohort Study underwent regionalized measurements of body fat via anthropometric methods and dual-energy X-ray absorptiometry. Multiple linear regression was used to evaluate body fat by HIV, with adjustment for age, Tanner stage, race, sex, and correlates of body fat in HIV-infected children. Percentage total body fat was compared with NHANES data. Results: Males accounted for 47% of the 369 HIV-infected and 51% of the 176 HEU children. Compared with HEU children, HIV-infected children were older, were more frequently non-Hispanic black, more frequently had Tanner stage ≥3, and had lower mean height (−0.32 compared with 0.29), weight (0.13 compared with 0.70), and BMI (0.33 compared with 0.63) z scores. On average, HIV-infected children had a 5% lower percentage total body fat (TotF), a 2.8% lower percentage extremity fat (EF), a 1.4% higher percentage trunk fat (TF), and a 10% higher trunk-to-extremity fat ratio (TEFR) than did the HEU children and a lower TotF compared with NHANES data. Stavudine use was associated with lower EF and higher TF and TEFR. Non-nucleotide reverse transcriptase inhibitor use was associated with higher TotF and EF and lower TEFR. Conclusion: Although BMI and total body fat were significantly lower in the HIV-infected children than in the HEU children, body fat distribution in the HIV-infected children followed a pattern associated with cardiovascular disease risk and possibly related to specific antiretroviral drugs. PMID:22049166

  17. Criticality safety evaluation for the Advanced Test Reactor enhanced low enriched uranium fuel elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montierth, Leland M.

    2016-07-19

    The Global Threat Reduction Initiative (GTRI) convert program is developing a high uranium density fuel based on a low enriched uranium (LEU) uranium-molybdenum alloy. Testing of prototypic GTRI fuel elements is necessary to demonstrate integrated fuel performance behavior and scale-up of fabrication techniques. GTRI Enhanced LEU Fuel (ELF) elements based on the ATR-Standard Size elements (all plates fueled) are to be fabricated for testing in the Advanced Test Reactor (ATR). While a specific ELF element design will eventually be provided for detailed analyses and in-core testing, this criticality safety evaluation (CSE) is intended to evaluate a hypothetical ELF element designmore » for criticality safety purposes. Existing criticality analyses have analyzed Standard (HEU) ATR elements from which controls have been derived. This CSE documents analysis that determines the reactivity of the hypothetical ELF fuel elements relative to HEU ATR elements and whether the existing HEU ATR element controls bound the ELF element. The initial calculations presented in this CSE analyzed the original ELF design, now referred to as Mod 0.1. In addition, as part of a fuel meat thickness optimization effort for reactor performance, other designs have been evaluated. As of early 2014 the most current conceptual designs are Mk1A and Mk1B, that were previously referred to as conceptual designs Mod 0.10 and Mod 0.11, respectively. Revision 1 evaluates the reactivity of the ATR HEU Mark IV elements for a comparison with the Mark VII elements.« less

  18. Steady-State Thermal-Hydraulics Analyses for the Conversion of BR2 to Low Enriched Uranium Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Licht, J.; Bergeron, A.; Dionne, B.

    The code PLTEMP/ANL version 4.2 was used to perform the steady-state thermal-hydraulic analyses of the BR2 research reactor for conversion from Highly-Enriched to Low Enriched Uranium fuel (HEU and LEU, respectively). Calculations were performed to evaluate different fuel assemblies with respect to the onset of nucleate boiling (ONB), flow instability (FI), critical heat flux (CHF) and fuel temperature at beginning of cycle conditions. The fuel assemblies were characteristic of fresh fuel (0% burnup), highest heat flux (16% burnup), highest power (32% burnup) and highest burnup (46% burnup). Results show that the high heat flux fuel element is limiting for ONB,more » FI, and CHF, for both HEU and LEU fuel, but that the high power fuel element produces similar margin in a few cases. The maximum fuel temperature similarly occurs in both the high heat flux and high power fuel assemblies for both HEU and LEU fuel. A sensitivity study was also performed to evaluate the variation in fuel temperature due to uncertainties in the thermal conductivity degradation associated with burnup.« less

  19. Nonproliferation Challenges in Space Defense Technology - PANEL

    NASA Technical Reports Server (NTRS)

    Houts, Michael G.

    2016-01-01

    The use of highly enriched uranium (HEU) almost always "helps" space fission systems. Nuclear Thermal Propulsion (NTP) and high power fission electric systems appear able to use < 20% enriched uranium with minimal / acceptable performance impacts. However, lower power, "entry level" systems may be needed for space fission technology to be developed and utilized. Low power (i.e. approx.1 kWe) fission systems may have an unacceptable performance penalty if LEU is used instead of HEU. Are there Ways to Support Non-Proliferation Objectives While Simultaneously Helping Enable the Development and Utilization of Modern Space Fission Power and Propulsion Systems?

  20. Safety analysis report for packaging, Oak Ridge Y-12 Plant, model DC-1 package with HEU oxide contents. Change pages for Rev.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This Safety Analysis Report for Packaging for the Oak Ridge Y-12 Plant for the Model DC-1 package with highly enriched uranium (HEU) oxide contents has been prepared in accordance with governing regulations form the Nuclear Regulatory Commission and the Department of Transportation and orders from the Department of energy. The fundamental safety requirements addressed by these regulations and orders pertain to the containment of radioactive material, radiation shielding, and nuclear subcriticality. This report demonstrates how these requirements are met.

  1. Transparency in a Pediatric Quality Improvement Collaborative: A Passionate Journey by NPC-QIC Clinicians and Parents.

    PubMed

    Lihn, Stacey L; Kugler, John D; Peterson, Laura E; Lannon, Carole M; Pickles, Diane; Beekman, Robert H

    2015-01-01

    Transparency-sharing data or information about outcomes, processes, protocols, and practices-may be the most powerful driver of health care improvement. In this special article, the development and growth of transparency within the National Pediatric Cardiology Quality Improvement Collaborative is described. The National Pediatric Cardiology Quality Improvement Collaborative transparency journey is guided by equal numbers of clinicians and parents of children with congenital heart disease working together in a Transparency Work Group. Activities are organized around four interrelated levels of transparency (individual, organizational, collaborative, and system), each with a specified purpose and aim. A number of Transparency Work Group recommendations have been operationalized. Aggregate collaborative performance is now reported on the public-facing web site. Specific information that the Transparency Work Group recommends centers provide to parents has been developed and published. Almost half of National Pediatric Cardiology Quality Improvement Collaborative centers participated in a pilot of transparently sharing their outcomes achieved with one another. Individual centers have also begun successfully implementing recommended transparency activities. Despite progress, barriers to full transparency persist, including health care organization concerns about potential negative effects of disclosure on reputation and finances, and lack of reliable definitions, data, and reporting standards for fair comparisons of centers. The National Pediatric Cardiology Quality Improvement Collaborative's transparency efforts have been a journey that continues, not a single goal or destination. Balanced participation of clinicians and parents has been a critical element of the collaborative's success on this issue. Plans are in place to guide implementation of additional transparency recommendations across all four levels, including extension of the activities beyond the collaborative to support transparency efforts in national cardiology and cardiac surgery societies. © 2015 Wiley Periodicals, Inc.

  2. Immunity to Measles, Mumps, and Rubella in US Children With Perinatal HIV Infection or Perinatal HIV Exposure Without Infection

    PubMed Central

    Siberry, George K.; Patel, Kunjal; Bellini, William J.; Karalius, Brad; Purswani, Murli U.; Burchett, Sandra K.; Meyer, William A.; Sowers, Sun Bae; Ellis, Angela; Van Dyke, Russell B.

    2015-01-01

    Background. Children with perinatal human immunodeficiency virus (HIV) infection (PHIV) may not be protected against measles, mumps, and rubella (MMR) because of impaired initial vaccine response or waning immunity. Our objectives were to estimate seroimmunity in PHIV-infected and perinatally HIV-exposed but uninfected (HEU) children and identify predictors of immunity in the PHIV cohort. Methods. PHIV and HEU children were enrolled in the Pediatric HIV/AIDS Cohort Study (PHACS) at ages 7–15 years from 2007 to 2009. At annual visits, demographic, laboratory, immunization, and clinical data were abstracted and serologic specimens collected. Most recent serologic specimen was used to determine measles seroprotection by plaque reduction neutralization assay and rubella seroprotection and mumps seropositivity by enzyme immunoassay. Sustained combination antiretroviral therapy (cART) was defined as taking cART for at least 3 months. Results. Among 428 PHIV and 221 HEU PHACS participants, the prevalence was significantly lower in PHIV children for measles seroprotection (57% [95% confidence interval {CI}, 52%–62%] vs 99% [95% CI, 96%–100%]), rubella seroprotection (65% [95% CI, 60%–70%] vs 98% [95% CI, 95%–100%]), and mumps seropositivity (59% [95% CI, 55%–64%] vs 97% [95% CI, 94%–99%]). On multivariable analysis, greater number of vaccine doses while receiving sustained cART and higher nadir CD4 percentage between last vaccine dose and serologic testing independently improved the cumulative prediction of measles seroprotection in PHIV. Predictors of rubella seroprotection and mumps seropositivity were similar. Conclusions. High proportions of PHIV-infected children, but not HEU children, lack serologic evidence of immunity to MMR, despite documented immunization and current cART. Effective cART before immunization is a strong predictor of current seroimmunity. PMID:26060291

  3. Metabolic Abnormalities and Viral Replication is Associated with Biomarkers of Vascular Dysfunction in HIV-Infected Children

    PubMed Central

    Miller, Tracie L.; Borkowsky, William; DiMeglio, Linda A.; Dooley, Laurie; Geffner, Mitchell E.; Hazra, Rohan; McFarland, Elizabeth J.; Mendez, Armando J.; Patel, Kunjal; Siberry, George K.; Van Dyke, Russell B.; Worrell, Carol J.; Jacobson, Denise L.

    2011-01-01

    Objectives Human immunodeficiency virus (HIV)-infected children may be at risk for premature cardiovascular disease. We compared levels of biomarkers of vascular dysfunction among HIV-infected children with and without hyperlipidemia to HIV-exposed, uninfected children (HEU) enrolled in the Pediatric HIV/AIDS Cohort Study (PHACS), and determined factors associated with these biomarkers. Design Prospective cohort study Methods Biomarkers of inflammation (C-reactive protein (CRP), interleukin-6 (IL-6), and monocyte chemoattractant protein-1 (MCP1)); coagulant dysfunction (fibrinogen and P-selectin); endothelial dysfunction (soluble intracellular cell adhesion molecule-1 (sICAM), soluble vascular cell adhesion molecule-1 (sVCAM), and E-selectin); and metabolic dysfunction (adiponectin) were measured in 226 HIV-infected and 140 HEU children. Anthropometry, body composition, lipids, glucose, insulin, HIV disease severity, and antiretroviral therapy were recorded. Results The median ages were 12.3 y (HIV-infected) and 10.1 y (HEU). Body mass index (BMI) Z-scores, waist and hip circumference, and percent body fat were lower among HIV-infected. Total and non-HDL cholesterol and triglycerides were higher in HIV-infected children. HIV-infected children had higher MCP-1, fibrinogen, sICAM, and sVCAM levels. In multivariable analyses in the HIV-infected children alone, BMI z-score was associated with higher CRP and fibrinogen, but lower MCP-1 and sVCAM. Unfavorable lipid profiles were positively associated with IL6, MCP1, fibrinogen, and P- and E-selectin, whereas increased HIV viral load was associated with markers of inflammation (MCP1 and CRP) and endothelial dysfunction (sICAM and sVCAM). Conclusions HIV-infected children have higher levels of biomarkers of vascular dysfunction than do HEU children. Risk factors associated with higher biomarkers include unfavorable lipid levels and active HIV replication. PMID:22136114

  4. Neurodevelopmental outcomes in HIV-exposed-uninfected children versus those not exposed to HIV

    PubMed Central

    Kerr, Stephen J.; Puthanakit, Thanyawee; Vibol, Ung; Aurpibul, Linda; Vonthanak, Sophan; Kosalaraksa, Pope; Kanjanavanit, Suparat; Hansudewechakul, Rawiwan; Wongsawat, Jurai; Luesomboon, Wicharn; Ratanadilok, Kattiya; Prasitsuebsai, Wasana; Pruksakaew, Kanchana; van der Lugt, Jasper; Paul, Robert; Ananworanich, Jintanat; Valcour, Victor

    2014-01-01

    Human immunodeficiency virus (HIV)-negative children born to HIV-infected mothers may exhibit differences in neurodevelopment (ND) compared to age- and gender-matched controls whose lives have not been affected by HIV. This could occur due to exposure to HIV and antiretroviral agents in utero and perinatally, or differences in the environment in which they grow up. This study assessed neurodevelopmental outcomes in HIV-exposed uninfected (HEU) and HIV-unexposed uninfected (HUU) children enrolled as controls in a multicenter ND study from Thailand and Cambodia. One hundred sixty HEU and 167 HUU children completed a neurodevelopmental assessment using the Beery Visual Motor Integration (VMI) test, Color Trails, Perdue Pegboard, and Child Behavior Checklist (CBCL). Thai children (n = 202) also completed the Wechsler Intelligence Scale (IQ) and Stanford-Binet II memory tests. In analyses adjusted for caregiver education, parent as caregiver, household income, age, and ethnicity, statistically significant lower scores were seen on verbal IQ (VIQ), full-scale IQ (FSIQ), and Binet Bead Memory among HEU compared to HUU. The mean (95% CI) differences were −6.13 (−10.3 to −1.96), p = 0.004; −4.57 (−8.80 to −0.35), p = 0.03; and −3.72 (−6.57 to −0.88), p = 0.01 for VIQ, FSIQ, and Binet Bead Memory, respectively. We observed no significant differences in performance IQ, other Binet memory domains, Color Trail, Perdue Pegboard, Beery VMI, or CBCL test scores. We conclude that HEU children evidence reductions in some neurodevelopmental outcomes compared to HUU; however, these differences are small and it remains unclear to what extent they have immediate and long-term clinical significance. PMID:24878112

  5. The effect of daily co-trimoxazole prophylaxis on natural development of antibody-mediated immunity against P. falciparum malaria infection in HIV-exposed uninfected Malawian children.

    PubMed

    Longwe, Herbert; Jambo, Kondwani C; Phiri, Kamija S; Mbeye, Nyanyiwe; Gondwe, Thandile; Hall, Tom; Tetteh, Kevin K A; Drakeley, Chris; Mandala, Wilson L

    2015-01-01

    Co-trimoxazole prophylaxis, currently recommended in HIV-exposed, uninfected (HEU) children as protection against opportunistic infections, also has some anti-malarial efficacy. We determined whether daily co-trimoxazole prophylaxis affects the natural development of antibody-mediated immunity to blood-stage Plasmodium falciparum malaria infection. Using an enzyme-linked immunosorbent assay, we measured antibodies to 8 Plasmodium falciparum antigens (AMA-1, MSP-119, MSP-3, PfSE, EBA-175RII, GLURP R0, GLURP R2 and CSP) in serum samples from 33 HEU children and 31 HIV-unexposed, uninfected (HUU) children, collected at 6, 12 and 18 months of age. Compared to HIV-uninfected children, HEU children had significantly lower levels of specific IgG against AMA-1 at 6 months (p = 0.001), MSP-119 at 12 months (p = 0.041) and PfSE at 6 months (p = 0.038), 12 months (p = 0.0012) and 18 months (p = 0.0097). No differences in the IgG antibody responses against the rest of the antigens were observed between the two groups at all time points. The breadth of specificity of IgG response was reduced in HEU children compared to HUU children during the follow up period. Co-trimoxazole prophylaxis seems to reduce IgG antibody responses to P. falciparum blood stage antigens, which could be as a result of a reduction in exposure of those children under this regime. Although antibody responses were regarded as markers of exposure in this study, further studies are required to establish whether these responses are correlated in any way to clinical immunity to malaria.

  6. The Effect of Daily Co-Trimoxazole Prophylaxis on Natural Development of Antibody-Mediated Immunity against P. falciparum Malaria Infection in HIV-Exposed Uninfected Malawian Children

    PubMed Central

    Longwe, Herbert; Jambo, Kondwani C.; Phiri, Kamija S.; Mbeye, Nyanyiwe; Gondwe, Thandile; Hall, Tom; Tetteh, Kevin K. A.

    2015-01-01

    Background and Objectives Co-trimoxazole prophylaxis, currently recommended in HIV-exposed, uninfected (HEU) children as protection against opportunistic infections, also has some anti-malarial efficacy. We determined whether daily co-trimoxazole prophylaxis affects the natural development of antibody-mediated immunity to blood-stage Plasmodium falciparum malaria infection. Methods Using an enzyme-linked immunosorbent assay, we measured antibodies to 8Plasmodium falciparum antigens (AMA-1, MSP-119, MSP-3, PfSE, EBA-175RII, GLURP R0, GLURP R2 and CSP) in serum samples from 33 HEU children and 31 HIV-unexposed, uninfected (HUU) children, collected at 6, 12 and 18 months of age. Results Compared to HIV-uninfected children, HEU children had significantly lower levels of specific IgG against AMA-1 at 6 months (p = 0.001), MSP-119 at 12 months (p = 0.041) and PfSE at 6 months (p = 0.038), 12 months (p = 0.0012) and 18 months (p = 0.0097). No differences in the IgG antibody responses against the rest of the antigens were observed between the two groups at all time points. The breadth of specificity of IgG response was reduced in HEU children compared to HUU children during the follow up period. Conclusions Co-trimoxazole prophylaxis seems to reduce IgG antibody responses to P. falciparum blood stage antigens, which could be as a result of a reduction in exposure of those children under this regime. Although antibody responses were regarded as markers of exposure in this study, further studies are required to establish whether these responses are correlated in any way to clinical immunity to malaria. PMID:25807475

  7. Neurodevelopmental outcomes in HIV-exposed-uninfected children versus those not exposed to HIV.

    PubMed

    Kerr, Stephen J; Puthanakit, Thanyawee; Vibol, Ung; Aurpibul, Linda; Vonthanak, Sophan; Kosalaraksa, Pope; Kanjanavanit, Suparat; Hansudewechakul, Rawiwan; Wongsawat, Jurai; Luesomboon, Wicharn; Ratanadilok, Kattiya; Prasitsuebsai, Wasana; Pruksakaew, Kanchana; van der Lugt, Jasper; Paul, Robert; Ananworanich, Jintanat; Valcour, Victor

    2014-01-01

    Human immunodeficiency virus (HIV)-negative children born to HIV-infected mothers may exhibit differences in neurodevelopment (ND) compared to age- and gender-matched controls whose lives have not been affected by HIV. This could occur due to exposure to HIV and antiretroviral agents in utero and perinatally, or differences in the environment in which they grow up. This study assessed neurodevelopmental outcomes in HIV-exposed uninfected (HEU) and HIV-unexposed uninfected (HUU) children enrolled as controls in a multicenter ND study from Thailand and Cambodia. One hundred sixty HEU and 167 HUU children completed a neurodevelopmental assessment using the Beery Visual Motor Integration (VMI) test, Color Trails, Perdue Pegboard, and Child Behavior Checklist (CBCL). Thai children (n = 202) also completed the Wechsler Intelligence Scale (IQ) and Stanford-Binet II memory tests. In analyses adjusted for caregiver education, parent as caregiver, household income, age, and ethnicity, statistically significant lower scores were seen on verbal IQ (VIQ), full-scale IQ (FSIQ), and Binet Bead Memory among HEU compared to HUU. The mean (95% CI) differences were -6.13 (-10.3 to -1.96), p = 0.004; -4.57 (-8.80 to -0.35), p = 0.03; and -3.72 (-6.57 to -0.88), p = 0.01 for VIQ, FSIQ, and Binet Bead Memory, respectively. We observed no significant differences in performance IQ, other Binet memory domains, Color Trail, Perdue Pegboard, Beery VMI, or CBCL test scores. We conclude that HEU children evidence reductions in some neurodevelopmental outcomes compared to HUU; however, these differences are small and it remains unclear to what extent they have immediate and long-term clinical significance.

  8. Vitamin D insufficiency in HIV-infected pregnant women receiving antiretroviral therapy is not associated with morbidity, mortality or growth impairment in their uninfected infants in Botswana.

    PubMed

    Powis, Kathleen; Lockman, Shahin; Smeaton, Laura; Hughes, Michael D; Fawzi, Wafaie; Ogwu, Anthony; Moyo, Sikhulile; van Widenfelt, Erik; von Oettingen, Julia; Makhema, Joseph; Essex, Max; Shapiro, Roger L

    2014-11-01

    Low maternal 25(OH)D (vitamin D) values have been associated with higher mortality and impaired growth among HIV-exposed uninfected (HEU) infants of antiretroviral (ART)-naive women. These associations have not been studied among HEU infants of women receiving ART. We performed a nested case-control study in the Botswana Mma Bana Study, a study providing ART to women during pregnancy and breastfeeding. Median maternal vitamin D values, and the proportion with maternal vitamin D insufficiency, were compared between women whose HEU infants experienced morbidity/mortality during 24 months of follow-up and women with nonhospitalized HEU infants. Growth faltering was assessed for never hospitalized infants attending the 24-month-of-life visit. Multivariate logistic regression models determined associations between maternal vitamin D insufficiency and infant morbidity/mortality and growth faltering. Delivery plasma was available and vitamin D levels assayable from 119 (86%) of 139 cases and 233 (84%) of 278 controls, and did not differ significantly between cases and controls [median: 36.7 ng/mL, interquartile range (IQR): 29.1-44.7 vs. 37.1 ng/mL, IQR: 30.0-47.2, P = 0.32]. Vitamin D insufficiency (<32 ng/mL) was recorded among 112 (31.8%) of 352 women at delivery and occurred most frequently among women delivering in winter. Multivariate logistic regression models adjusted for maternal HIV disease progression did not show associations between maternal vitamin D insufficiency at delivery and child morbidity/mortality, or 24-month-of-life growth faltering. Vitamin D insufficiency was common among ART-treated pregnant women in Botswana, but was not associated with morbidity, mortality or growth impairment in their HIV-uninfected children.

  9. TREAT Transient Analysis Benchmarking for the HEU Core

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kontogeorgakos, D. C.; Connaway, H. M.; Wright, A. E.

    2014-05-01

    This work was performed to support the feasibility study on the potential conversion of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory from the use of high enriched uranium (HEU) fuel to the use of low enriched uranium (LEU) fuel. The analyses were performed by the GTRI Reactor Conversion staff at the Argonne National Laboratory (ANL). The objective of this study was to benchmark the transient calculations against temperature-limited transients performed in the final operating HEU TREAT core configuration. The MCNP code was used to evaluate steady-state neutronics behavior, and the point kinetics code TREKIN was used tomore » determine core power and energy during transients. The first part of the benchmarking process was to calculate with MCNP all the neutronic parameters required by TREKIN to simulate the transients: the transient rod-bank worth, the prompt neutron generation lifetime, the temperature reactivity feedback as a function of total core energy, and the core-average temperature and peak temperature as a functions of total core energy. The results of these calculations were compared against measurements or against reported values as documented in the available TREAT reports. The heating of the fuel was simulated as an adiabatic process. The reported values were extracted from ANL reports, intra-laboratory memos and experiment logsheets and in some cases it was not clear if the values were based on measurements, on calculations or a combination of both. Therefore, it was decided to use the term “reported” values when referring to such data. The methods and results from the HEU core transient analyses will be used for the potential LEU core configurations to predict the converted (LEU) core’s performance.« less

  10. Transparent Proxy for Secure E-Mail

    NASA Astrophysics Data System (ADS)

    Michalák, Juraj; Hudec, Ladislav

    2010-05-01

    The paper deals with the security of e-mail messages and e-mail server implementation by means of a transparent SMTP proxy. The security features include encryption and signing of transported messages. The goal is to design and implement a software proxy for secure e-mail including its monitoring, administration, encryption and signing keys administration. In particular, we focus on automatic public key on-the-fly encryption and signing of e-mail messages according to S/MIME standard by means of an embedded computer system whose function can be briefly described as a brouter with transparent SMTP proxy.

  11. Progress on RERTR activities in Argentina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balart, S.; Calzetta, O.; Cristini, P.

    2008-07-15

    Since last RERTR meeting, several tasks involving RERTR activities continued deploying in Argentina: through an agreement between CNEA and US-DoE final steps in the RA-6 reactor core conversion from HEU to LEU are taking place; by means of a return campaign of 42 US origin SNF in the frame of the US-SNF FRR program; an effective minimization of HEU inventory is close to be accomplished; development of a LEU dispersed U-Mo fuel prototype, to be irradiated in a high flux reactor in the frame of the ARG/4/092 IAEA's Technical Cooperation project is progressing; very high density monolithic U-Mo miniplates andmore » plates using MEU and LEU fuel with Zry-4 cladding were developed to be irradiated as a part of the RERTR program irradiation experiment; atomistic modeling prediction (BFS techniques and first principles) enabled to find some trends on the interaction phases; diffusion couples tests under X-ray synchrotron analysis allowed the characterization of several phases involving U-Mo(-Zr) / Al(-Si); finally CNEA continued spreading high quality LEU technology for fission RI production by means of agreements with different producers interested on HEU-LEU conversion. (author)« less

  12. Use of the Hugoniot elastic limit in laser shockwave experiments to relate velocity measurements

    NASA Astrophysics Data System (ADS)

    Smith, James A.; Lacy, Jeffrey M.; Lévesque, Daniel; Monchalin, Jean-Pierre; Lord, Martin

    2016-02-01

    The US National Nuclear Security Agency has a Global Threat Reduction Initiative (GTRI) with the goal of reducing the worldwide use of high-enriched uranium (HEU). A salient component of that initiative is the conversion of research reactors from HEU to low enriched uranium (LEU) fuels. An innovative fuel is being developed to replace HEU in high-power research reactors. The new LEU fuel is a monolithic fuel made from a U-Mo alloy foil encapsulated in Al-6061 cladding. In order to support the fuel qualification process, the Laser Shockwave Technique (LST) is being developed to characterize the clad-clad and fuel-clad interface strengths in fresh and irradiated fuel plates. This fuel-cladding interface qualification will ensure the survivability of the fuel plates in the harsh reactor environment even under abnormal operating conditions. One of the concerns of the project is the difficulty of calibrating and standardizing the laser shock technique. An analytical study under development and experimental testing supports the hypothesis that the Hugoniot Elastic Limit (HEL) in materials can be a robust and simple benchmark to compare stresses generated by different laser shock systems.

  13. Transparency in the ePortfolio Creation Process

    ERIC Educational Resources Information Center

    Jones, Stephanie A.; Downs, Elizabeth; Jenkins, Stephen J.

    2015-01-01

    This paper presents the findings of a study examining the effect of transparency on the ePortfolio creation process. The purpose of the study was to examine whether increased awareness of other students' ePortfolios through the implementation of transparency and peer review would positively affect the quality of performance of school library media…

  14. 48 CFR 4.1400 - Scope of subpart.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... This subpart implements section 2 of the Federal Funding Accountability and Transparency Act of 2006 (Pub. L. 109-282), as amended by section 6202 of the Government Funding Transparency Act of 2008 (Pub...

  15. Thermal Properties for the Thermal-Hydraulics Analyses of the BR2 Maximum Nominal Heat Flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dionne, B.; Bergeron, A.; Licht, J. R.

    2015-02-01

    This memo describes the assumptions and references used in determining the thermal properties for the various materials used in the BR2 HEU (93% enriched in 235U) to LEU (19.75% enriched in 235U) conversion feasibility analysis. More specifically, this memo focuses on the materials contained within the pressure vessel (PV), i.e., the materials that are most relevant to the study of impact of the change of fuel from HEU to LEU. Section 2 provides a summary of the thermal properties in the form of tables while the following sections and appendices present the justification of these values. Section 3 presents amore » brief background on the approach used to evaluate the thermal properties of the dispersion fuel meat and specific heat capacity. Sections 4 to 7 discuss the material properties for the following materials: i) aluminum, ii) dispersion fuel meat (UAlx-Al and U-7Mo-Al), iii) beryllium, and iv) stainless steel. Section 8 discusses the impact of irradiation on material properties. Section 9 summarizes the material properties for typical operating temperatures. Appendix A elaborates on how to calculate dispersed phase’s volume fraction. Appendix B provides a revised methodology for determining the thermal conductivity as a function of burnup for HEU and LEU.« less

  16. Orsphere: Physics Measurments For Bare, HEU(93.2)-Metal Sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, Margaret A.; Bess, John D.; Briggs, J. Blair

    In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared withmore » the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files” (Reference 1). While performing the ORSphere experiments care was taken to accurately document component dimensions (±0.0001 inches), masses (±0.01 g), and material data. The experiment was also set up to minimize the amount of structural material in the sphere proximity. Two, correlated spheres were evaluated and judged to be acceptable as criticality benchmark experiments. This evaluation is given in HEU-MET-FAST-100. The second, smaller sphere was used for additional reactor physics measurements. Worth measurements (Reference 1, 2, 3 and 4), the delayed neutron fraction (Reference 3, 4 and 5) and surface material worth coefficient (Reference 1 and 2) are all measured and judged to be acceptable as benchmark data. The prompt neutron decay (Reference 6), relative fission density (Reference 7) and relative neutron importance (Reference 7) were measured, but are not evaluated. Information for the evaluation was compiled from References 1 through 7, the experimental logbooks 8 and 9 ; additional drawings and notes provided by the experimenter; and communication with the lead experimenter, John T. Mihalczo.« less

  17. The RERTR Program status and progress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Travelli, A.

    1995-12-01

    The progress of the Reduced Enrichment Research and Test Reactor (RERTR) Program is described. The major events, findings, and activities of 1995 are reviewed after a brief summary of the results which the RERTR Program had achieved by the end of 1994. The revelation that Iraq was on the verge of developing a nuclear weapon at the time of the Gulf War, and that it was planning to do so by extracting HEU from the fuel of its research reactors, has given new impetus and urgency to the RERTR commitment of eliminating HEU use in research and test reactors worldwide.more » Development of advanced LEU research reactor fuels is scheduled to begin in October 1995. The Russian RERTR program, which aims to develop and demonstrate within the next five years the technical means needed to convert Russian-supplied research reactors to LEU fuels, is now in operation. A Statement of Intent was signed by high US and Chinese officials, endorsing cooperative activities between the RERTR program and Chinese laboratories involved in similar activities. Joint studies of LEU technical feasibility were completed for the SAFARI-I reactor in South Africa and for the ANS reactor in the US. A new study has been initiated for the FRM-II reactor in Germany. Significant progress was made on several aspects of producing {sup 99}Mo from fission targets utilizing LEU instead of HEU. A cooperation agreements is in place with the Indonesian BATAN. The first prototypical irradiation of an LEU metal-foil target for {sup 99}Mo production was accomplished in Indonesia. The TR-2 reactor, in Turkey, began conversion. SAPHIR, in Switzerland, was shut down. LEU fuel fabrication has begun for the conversion of two more US reactors. Twelve foreign reactors and nine domestic reactors have been fully converted. Approximately 60 % of the work required to eliminate the use of HEU in US-supplied research reactors has been accomplished.« less

  18. Immunity to Measles, Mumps, and Rubella in US Children With Perinatal HIV Infection or Perinatal HIV Exposure Without Infection.

    PubMed

    Siberry, George K; Patel, Kunjal; Bellini, William J; Karalius, Brad; Purswani, Murli U; Burchett, Sandra K; Meyer, William A; Sowers, Sun Bae; Ellis, Angela; Van Dyke, Russell B

    2015-09-15

    Children with perinatal human immunodeficiency virus (HIV) infection (PHIV) may not be protected against measles, mumps, and rubella (MMR) because of impaired initial vaccine response or waning immunity. Our objectives were to estimate seroimmunity in PHIV-infected and perinatally HIV-exposed but uninfected (HEU) children and identify predictors of immunity in the PHIV cohort. PHIV and HEU children were enrolled in the Pediatric HIV/AIDS Cohort Study (PHACS) at ages 7-15 years from 2007 to 2009. At annual visits, demographic, laboratory, immunization, and clinical data were abstracted and serologic specimens collected. Most recent serologic specimen was used to determine measles seroprotection by plaque reduction neutralization assay and rubella seroprotection and mumps seropositivity by enzyme immunoassay. Sustained combination antiretroviral therapy (cART) was defined as taking cART for at least 3 months. Among 428 PHIV and 221 HEU PHACS participants, the prevalence was significantly lower in PHIV children for measles seroprotection (57% [95% confidence interval {CI}, 52%-62%] vs 99% [95% CI, 96%-100%]), rubella seroprotection (65% [95% CI, 60%-70%] vs 98% [95% CI, 95%-100%]), and mumps seropositivity (59% [95% CI, 55%-64%] vs 97% [95% CI, 94%-99%]). On multivariable analysis, greater number of vaccine doses while receiving sustained cART and higher nadir CD4 percentage between last vaccine dose and serologic testing independently improved the cumulative prediction of measles seroprotection in PHIV. Predictors of rubella seroprotection and mumps seropositivity were similar. High proportions of PHIV-infected children, but not HEU children, lack serologic evidence of immunity to MMR, despite documented immunization and current cART. Effective cART before immunization is a strong predictor of current seroimmunity. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  19. Enhancing the performance of a tensioned metastable fluid detector based active interrogation system for the detection of SNM in <1 m3 containers using a D-D neutron interrogation source in moderated/reflected geometries

    NASA Astrophysics Data System (ADS)

    Grimes, T. F.; Hagen, A. R.; Archambault, B. C.; Taleyarkhan, R. P.

    2018-03-01

    This paper describes the development of a SNM detection system for interrogating 1m3 cargos via the combination of a D-D neutron interrogation source (with and without reflectors) and tensioned metastable fluid detectors (TMFDs). TMFDs have been previously shown (Taleyarkhan et al., 2008; Grimes et al., 2015; Grimes and Taleyarkhan, 2016; Archambault et al., 2017; Hagen et al., 2016) to be capable of using Threshold Energy Neutron Analysis (TENA) techniques to reject the ∼2.45 MeV D-D interrogating neutrons while still remaining sensitive to >2.45 MeV neutrons resulting from fission in the target (HEU) material. In order to enhance the performance, a paraffin reflector was included around the accelerator head. This reflector was used to direct neutrons into the package to increase the fission signal, lower the energy of the interrogating neutrons to increase the fission cross-section with HEU, and, also to direct interrogating neutrons away from the detectors in order to enhance the required discrimination between interrogating and fission neutrons. Experiments performed with a 239 Pu-Be neutron source and MnO2 indicated that impressive performance gains could be made by placing a parabolic paraffin moderator between the interrogation source and an air-filled cargo container with HEU placed at the center. However, experiments with other cargo fillers (as specified in the well-known ANSI N42.41-2007 report), and with HEU placed in locations other than the center of the package indicated that other reflector geometries might be superior due to over-"focusing" and the increased solid angle effects due to the accommodation of the moderator geometry. The best performance for the worst case of source location and box fill was obtained by placing the reflector only behind the D-D neutron source rather than in front of it. Finally, it was shown that there could be significant gains in the ability to detect concealed SNM by operating the system in multiple geometric configurations. Worst case scenarios were created by filling the box with hydrogenous material and placing the HEU as far away as possible from the neutron source. The performance of the system in the worst-case scenarios were greatly improved by exchanging the location of the accelerator and the opposite TMFD panel half way through interrogation. Using this operation, scenarios with positions of the concealed SNM that were once the most challenging to successfully detect became readily detectable.

  20. Plutonium Decontamination of Uranium using CO2 Cleaning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blau, M

    A concern of the Department of Energy (DOE) Environmental Management (EM) and Defense Programs (DP), and of the Los Alamos National Laboratory (LANL) and the Lawrence Livermore National Laboratory (LLNL), is the disposition of thousands of legacy and recently generated plutonium (Pu)-contaminated, highly enriched uranium (HEU) parts. These parts take up needed vault space. This presents a serious problem for LLNL, as site limit could result in the stoppage of future weapons work. The Office of Fissile Materials Disposition (NN-60) will also face a similar problem as thousands of HEU parts will be created with the disassembly of site-return pitsmore » for plutonium recovery when the Pit Disassembly and Conversion Facility (PDCF) at the Savannah River Site (SRS) becomes operational. To send HEU to the Oak Ridge National Laboratory and the Y-12 Plant for disposition, the contamination for metal must be less than 20 disintegrations per minute (dpm) of swipable transuranic per 100 cm{sup 2} of surface area or the Pu bulk contamination for oxide must be less than 210 parts per billion (ppb). LANL has used the electrolytic process on Pu-contaminated HEU weapon parts with some success. However, this process requires that a different fixture be used for every configuration; each fixture cost approximately $10K. Moreover, electrolytic decontamination leaches the uranium metal substrate (no uranium or plutonium oxide) from the HEU part. The leaching rate at the uranium metal grain boundaries is higher than that of the grains and depends on the thickness of the uranium oxide layer. As the leaching liquid flows past the HEU part, it carries away plutonium oxide contamination and uranium oxide. The uneven uranium metal surface created by the leaching becomes a trap for plutonium oxide contamination. In addition, other DOE sites have used CO{sub 2} cleaning for Pu decontamination successfully. In the 1990's, the Idaho National Engineering Laboratory investigated this technology and showed that CO{sub 2} pellet blasting (or CO{sub 2} cleaning) reduced both fixed and smearable contamination on tools. In 1997, LLNL proved that even tritium contamination could be removed from a variety of different matrices using CO{sub 2}cleaning. CO{sub 2} cleaning is a non-toxic, nonconductive, nonabrasive decontamination process whose primary cleaning mechanisms are: (1) Impact of the CO{sub 2} pellets loosens the bond between the contaminant and the substrate. (2) CO{sub 2} pellets shatter and sublimate into a gaseous state with large expansion ({approx}800 times). The expanding CO{sub 2} gas forms a layer between the contaminant and the substrate that acts as a spatula and peels off the contaminant. (3) Cooling of the contaminant assists in breaking its bond with the substrate. Thus, LLNL conducted feasibility testing to determine if CO{sub 2} pellet blasting could remove Pu contamination (e.g., uranium oxide) from uranium metal without abrading the metal matrix. This report contains a summary of events and the results of this test.« less

  1. Optical quantum memory based on electromagnetically induced transparency

    PubMed Central

    Ma, Lijun; Slattery, Oliver

    2017-01-01

    Electromagnetically induced transparency (EIT) is a promising approach to implement quantum memory in quantum communication and quantum computing applications. In this paper, following a brief overview of the main approaches to quantum memory, we provide details of the physical principle and theory of quantum memory based specifically on EIT. We discuss the key technologies for implementing quantum memory based on EIT and review important milestones, from the first experimental demonstration to current applications in quantum information systems. PMID:28828172

  2. Optical quantum memory based on electromagnetically induced transparency.

    PubMed

    Ma, Lijun; Slattery, Oliver; Tang, Xiao

    2017-04-01

    Electromagnetically induced transparency (EIT) is a promising approach to implement quantum memory in quantum communication and quantum computing applications. In this paper, following a brief overview of the main approaches to quantum memory, we provide details of the physical principle and theory of quantum memory based specifically on EIT. We discuss the key technologies for implementing quantum memory based on EIT and review important milestones, from the first experimental demonstration to current applications in quantum information systems.

  3. Substance-Treatment Professionals' Perceived Barriers to Incorporating Mindfulness Into Treatment.

    PubMed

    Edwards, Emily Rachel; Cohen, Mia Gintoft; Wupperman, Peggilee

    2016-12-05

    Despite scientific favor, psychological interventions supported by research are often underutilized by practitioners due to perceived obstacles in implementation. Increased transparency between researchers and practitioners throughout treatment development and dissemination is therefore necessary. The rising popularity of mindfulness-based approaches in the treatment of substance-use disorders suggests such transparency is necessary in further developing, disseminating, and implementing such approaches within the context of substance treatment. The present study aimed to increase transparency by surveying substance-treatment professionals regarding their perceptions of barriers to adopting mindfulness in the treatment of substance use. Substance-treatment professionals throughout the United States (N = 103) completed an online survey about their perceptions of potential barriers to implementing mindfulness into substance treatment. Overall, professionals were moderately familiar with mindfulness as a treatment for substance use. Approximately one-third reported providing mindfulness in substance treatment; however, only 7% reported providing mindfulness using a research-supported treatment manual. Across professionals of various backgrounds, the need for further training was rated as the greatest barrier to implementation. Results suggest that practitioners are generally familiar with and willing to implement mindfulness in the treatment of substance use. Future research and implementation efforts should focus on methods of increasing training availability, accessibility, and relevance to address the needs and expectations of substance-treatment professionals.

  4. Communication of scientific uncertainty: international case studies on the development of folate and vitamin D Dietary Reference Values.

    PubMed

    Brown, Kerry A; de Wit, Liesbeth; Timotijevic, Lada; Sonne, Anne-Mette; Lähteenmäki, Liisa; Brito Garcia, Noé; Jeruszka-Bielak, Marta; Sicińska, Ewa; Moore, Alana N; Lawrence, Mark; Raats, Monique M

    2015-06-01

    Transparent evidence-based decision making has been promoted worldwide to engender trust in science and policy making. Yet, little attention has been given to transparency implementation. The degree of transparency (focused on how uncertain evidence was handled) during the development of folate and vitamin D Dietary Reference Values was explored in three a priori defined areas: (i) value request; (ii) evidence evaluation; and (iii) final values. Qualitative case studies (semi-structured interviews and desk research). A common protocol was used for data collection, interview thematic analysis and reporting. Results were coordinated via cross-case synthesis. Australia and New Zealand, Netherlands, Nordic countries, Poland, Spain and UK. Twenty-one interviews were conducted in six case studies. Transparency of process was not universally observed across countries or areas of the recommendation setting process. Transparency practices were most commonly seen surrounding the request to develop reference values (e.g. access to risk manager/assessor problem formulation discussions) and evidence evaluation (e.g. disclosure of risk assessor data sourcing/evaluation protocols). Fewer transparency practices were observed to assist with handling uncertainty in the evidence base during the development of quantitative reference values. Implementation of transparency policies may be limited by a lack of dedicated resources and best practice procedures, particularly to assist with the latter stages of reference value development. Challenges remain regarding the best practice for transparently communicating the influence of uncertain evidence on the final reference values. Resolving this issue may assist the evolution of nutrition risk assessment and better inform the recommendation setting process.

  5. RUSSIAN-ORIGIN HIGHLY ENRICHED URANIUM SPENT NUCLEAR FUEL SHIPMENT FROM BULGARIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly Cummins; Igor Bolshinsky; Ken Allen

    2009-07-01

    In July 2008, the Global Threat Reduction Initiative and the IRT 2000 research reactor in Sofia, Bulgaria, operated by the Institute for Nuclear Research and Nuclear Energy (INRNE), safely shipped 6.4 kilograms of Russian origin highly enriched uranium (HEU) spent nuclear fuel (SNF) to the Russian Federation. The shipment, which resulted in the removal of all HEU from Bulgaria, was conducted by truck, barge, and rail modes of transport across two transit countries before reaching the final destination at the Production Association Mayak facility in Chelyabinsk, Russia. This paper describes the work, equipment, organizations, and approvals that were required tomore » complete the spent fuel shipment and provides lessons learned that might assist other research reactor operators with their own spent nuclear fuel shipments.« less

  6. Transient analysis for the tajoura critical facility with IRT-2M HEU fuel and IRT-4M leu fuel : ANL independent verification results.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garner, P. L.; Hanan, N. A.

    2005-12-02

    Calculations have been performed for postulated transients in the Critical Facility at the Tajoura Nuclear Research Center (TNRC) in Libya. These calculations have been performed at the request of staff of the Renewable Energy and Water Desalinization Research Center (REWDRC) who are performing similar calculations. The transients considered were established during a working meeting between ANL and REWDRC staff on October 1-2, 2005 and subsequent email correspondence. Calculations were performed for the current high-enriched uranium (HEU) core and the proposed low-enriched uranium (LEU) core. These calculations have been performed independently from those being performed by REWDRC and serve as onemore » step in the verification process.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brunett, A. J.; Fei, T.; Strons, P. S.

    The Transient Reactor Test Facility (TREAT), located at Idaho National Laboratory (INL), is a test facility designed to evaluate the performance of reactor fuels and materials under transient accident conditions. The facility, an air-cooled, graphite-moderated reactor designed to utilize fuel containing high-enriched uranium (HEU), has been in non-operational standby status since 1994. Currently, in support of the missions of the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Material Management and Minimization (M3) Reactor Conversion Program, a new core design is being developed for TREAT that will utilize low-enriched uranium (LEU). The primary objective of this conversion effort ismore » to design an LEU core that is capable of meeting the performance characteristics of the existing HEU core. Minimal, if any, changes are anticipated for the supporting systems (e.g. reactor trip system, filtration/cooling system, etc.); therefore, the LEU core must also be able to function with the existing supporting systems, and must also satisfy acceptable safety limits. In support of the LEU conversion effort, a range of ancillary safety analyses are required to evaluate the LEU core operation relative to that of the existing facility. These analyses cover neutronics, shielding, and thermal hydraulic topics that have been identified as having the potential to have reduced safety margins due to conversion to LEU fuel, or are required to support the required safety analyses documentation. The majority of these ancillary tasks have been identified in [1] and [2]. The purpose of this report is to document the ancillary safety analyses that have been performed at Argonne National Laboratory during the early stages of the LEU design effort, and to describe ongoing and anticipated analyses. For all analyses presented in this report, methodologies are utilized that are consistent with, or improved from, those used in analyses for the HEU Final Safety Analysis Report (FSAR) [3]. Depending on the availability of historical data derived from HEU TREAT operation, results calculated for the LEU core are compared to measurements obtained from HEU TREAT operation. While all analyses in this report are largely considered complete and have been reviewed for technical content, it is important to note that all topics will be revisited once the LEU design approaches its final stages of maturity. For most safety significant issues, it is expected that the analyses presented here will be bounding, but additional calculations will be performed as necessary to support safety analyses and safety documentation. It should also be noted that these analyses were completed as the LEU design evolved, and therefore utilized different LEU reference designs. Preliminary shielding, neutronic, and thermal hydraulic analyses have been completed and have generally demonstrated that the various LEU core designs will satisfy existing safety limits and standards also satisfied by the existing HEU core. These analyses include the assessment of the dose rate in the hodoscope room, near a loaded fuel transfer cask, above the fuel storage area, and near the HEPA filters. The potential change in the concentration of tramp uranium and change in neutron flux reaching instrumentation has also been assessed. Safety-significant thermal hydraulic items addressed in this report include thermally-induced mechanical distortion of the grid plate, and heating in the radial reflector.« less

  8. [The transparency commission: evaluation and re-evaluation].

    PubMed

    Bergmann, J F

    The purpose of the French Transparency Commission is to provide scientific advice concerning the usefulness, interest and good use of drugs. The work of the Transparency Commission lies at the interface between the French or European marketing approval procedures and the health and economic prerequisites of the French community. The opinion of the French Transparency Commission is used to assess the medical service provided by a new drug and the improvement of this medical service subsequent to its use. This opinion is taken into consideration for establishing the reimbursement rate applied by the social security organizations and the selling price set by the administration. The expert opinions and recommendations established by the Transparency Commission participate in implementing good use of drugs.

  9. Planning, Preparation, and Transport of the High-Enriched Uranium Spent Nuclear Fuel from the Czech Republic to the Russian Federation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. J. Tyacke; I. Bolshinsky; Frantisek Svitak

    The United States, Russian Federation, and the International Atomic Energy Agency have been working together on a program called the Russian Research Reactor Fuel Return (RRRFR) Program, which is part of the Global Threat Reduction Initiative. The purpose of this program is to return Soviet or Russian-supplied high-enriched uranium (HEU) fuel, currently stored at Russian-designed research reactors throughout the world, to Russia. In February 2003, the RRRFR Program began discussions with the Nuclear Research Institute (NRI) in Rež, Czech Republic, about returning their HEU spent nuclear fuel to the Russian Federation for reprocessing. In March 2005, the U.S. Department ofmore » Energy signed a contract with NRI to perform all activities needed for transporting their HEU spent nuclear fuel to Russia. After 2 years of intense planning, preparations, and coordination at NRI and with three other countries, numerous organizations and agencies, and a Russian facility, this shipment is scheduled for completion before the end of 2007. This paper will provide a summary of activities completed for making this international shipment. This paper contains an introduction and background of the RRRFR Program and the NRI shipment project. It summarizes activities completed in preparation for the shipment, including facility preparations at NRI in Rež and FSUE “Mayak” in Ozyorsk, Russia; a new transportation cask system; regulatory approvals; transportation planning and preparation in the Czech Republic, Slovakia, Ukraine, and the Russian Federation though completion of the Unified Project and Special Ecological Programs. The paper also describes fuel loading and cask preparations at NRI and final preparations/approvals for transporting the shipment across the Czech Republic, Slovakia, Ukraine, and the Russian Federation to FSUE Mayak where the HEU spent nuclear fuel will be processed, the uranium will be downblended and made into low-enriched uranium fuel for commercial reactor use, and the high-level waste from the processing will be stabilized and stored for less than 20 years before being sent back to the Czech Republic for final disposition. Finally, the paper contains a section for the summary and conclusions.« less

  10. A neutronics feasibility study for the LEU conversion of Poland's Maria research reactor.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bretscher, M. M.

    1998-10-14

    The MARIA reactor is a high-flux multipurpose research reactor which is water-cooled and moderated with both beryllium and water. Standard HEU (80% {sup 235}U)fuel assemblies consist of six concentric fuel tubes of a U-Al alloy clad in aluminum. Although the inventory of HEU (80%) fuel is nearly exhausted, a supply of highly-loaded 36%-enriched fuel assemblies is available at the reactor site. Neutronic equilibrium studies have been made to determine the relative performance of fuels with enrichments of 80%, 36% and 19.7%. These studies indicate that LEU (19.7%) densities of about 2.5 gU/cm{sup 3} and 3.8 gU/cm{sup 3} are required tomore » match the performance of the MARIA reactor with 80%-enriched and with 36%-enriched fuels, respectively.« less

  11. The Mailbox Computer System for the IAEA verification experiment on HEU downlending at the Portsmouth Gaseous Diffusion Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aronson, A.L.; Gordon, D.M.

    IN APRIL 1996, THE UNITED STATES (US) ADDED THE PORTSMOUTH GASEOUS DIFFUSION PLANT TO THE LIST OF FACILITIES ELIGIBLE FOR THE APPLICATION OF INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA) SAFEGUARDS. AT THAT TIME, THE US PROPOSED THAT THE IAEA CARRY OUT A ''VERIFICATION EXPERIMENT'' AT THE PLANT WITH RESPECT TO DOOWNBLENDING OF ABOUT 13 METRIC TONS OF HIGHLY ENRICHED URANIUM (HEU) IN THE FORM OF URANIUM HEXAFLUROIDE (UF6). DURING THE PERIOD DECEMBER 1997 THROUGH JULY 1998, THE IAEA CARRIED OUT THE REQUESTED VERIFICATION EXPERIMENT. THE VERIFICATION APPROACH USED FOR THIS EXPERIMENT INCLUDED, AMONG OTHER MEASURES, THE ENTRY OF PROCESS-OPERATIONAL DATA BYmore » THE FACILITY OPERATOR ON A NEAR-REAL-TIME BASIS INTO A ''MAILBOX'' COMPUTER LOCATED WITHIN A TAMPER-INDICATING ENCLOSURE SEALED BY THE IAEA.« less

  12. Developing a laser shockwave model for characterizing diffusion bonded interfaces

    NASA Astrophysics Data System (ADS)

    Lacy, Jeffrey M.; Smith, James A.; Rabin, Barry H.

    2015-03-01

    The US National Nuclear Security Agency has a Global Threat Reduction Initiative (GTRI) with the goal of reducing the worldwide use of high-enriched uranium (HEU). A salient component of that initiative is the conversion of research reactors from HEU to low enriched uranium (LEU) fuels. An innovative fuel is being developed to replace HEU in high-power research reactors. The new LEU fuel is a monolithic fuel made from a U-Mo alloy foil encapsulated in Al-6061 cladding. In order to support the fuel qualification process, the Laser Shockwave Technique (LST) is being developed to characterize the clad-clad and fuel-clad interface strengths in fresh and irradiated fuel plates. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves to characterize interfaces in nuclear fuel plates. However, because the deposition of laser energy into the containment layer on a specimen's surface is intractably complex, the shock wave energy is inferred from the surface velocity measured on the backside of the fuel plate and the depth of the impression left on the surface by the high pressure plasma pulse created by the shock laser. To help quantify the stresses generated at the interfaces, a finite element method (FEM) model is being utilized. This paper will report on initial efforts to develop and validate the model by comparing numerical and experimental results for back surface velocities and front surface depressions in a single aluminum plate representative of the fuel cladding.

  13. Tunable optical analog to electromagnetically induced transparency in graphene-ring resonators system.

    PubMed

    Wang, Yonghua; Xue, Chenyang; Zhang, Zengxing; Zheng, Hua; Zhang, Wendong; Yan, Shubin

    2016-12-12

    The analogue of electromagnetically induced transparency in optical ways has shown great potential in optical delay and quantum-information technology due to its flexible design and easy implementation. The chief drawback for these devices is the bad tunability. Here we demonstrate a tunable optical transparency system formed by graphene-silicon microrings which could control the transparent window by electro-optical means. The device consists of cascaded coupled ring resonators and a graphene/graphene capacitor which integrated on one of the rings. By tuning the Fermi level of the graphene sheets, we can modulate the round-trip ring loss so that the transparency window can be dynamically tuned. The results provide a new method for the manipulation and transmission of light in highly integrated optical circuits and quantum information storage devices.

  14. Assessment of Electro-Mechanic Technician Qualifications in the Context of European Transparency Tools

    ERIC Educational Resources Information Center

    Ozcan, Mustafa; Vuranok, Turan Tolga; Ball, Claudia

    2017-01-01

    Purpose: This study explores the applicability and transferability of tools developed for the realization of comparability and transparency of qualifications across Europe. It relates to the implementation of the European Credit System for Vocational Education and Training (ECVET) and the European Qualifications Framework (EQF) in the automotive…

  15. Scribed transparency microplates mounted on a modified standard microplate.

    PubMed

    Cheong, Brandon Huey-Ping; Chua, Wei Seong; Liew, Oi Wah; Ng, Tuck Wah

    2014-08-01

    The immense cost effectiveness of using transparencies as analyte handling implements in microplate instrumentation offers the possibility of application even in resource-limited laboratories. In this work, a standard microplate was adapted to serve as the permanent base for disposable scribed transparencies. The approach is shown to ameliorate evaporation, which can affect assay accuracy when analytes need to be incubated for some time. It also offers assurance against fluorescence measurement errors due to the cross-talk of samples from adjacent wells. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Tunable optical analog to electromagnetically induced transparency in graphene-ring resonators system

    PubMed Central

    Wang, Yonghua; Xue, Chenyang; Zhang, Zengxing; Zheng, Hua; Zhang, Wendong; Yan, Shubin

    2016-01-01

    The analogue of electromagnetically induced transparency in optical ways has shown great potential in optical delay and quantum-information technology due to its flexible design and easy implementation. The chief drawback for these devices is the bad tunability. Here we demonstrate a tunable optical transparency system formed by graphene-silicon microrings which could control the transparent window by electro-optical means. The device consists of cascaded coupled ring resonators and a graphene/graphene capacitor which integrated on one of the rings. By tuning the Fermi level of the graphene sheets, we can modulate the round-trip ring loss so that the transparency window can be dynamically tuned. The results provide a new method for the manipulation and transmission of light in highly integrated optical circuits and quantum information storage devices. PMID:27941895

  17. The transformative nature of transparency in research funding.

    PubMed

    Mietchen, Daniel

    2014-12-01

    Central to research funding are grant proposals that researchers send in to potential funders for review, in the hope of approval. A survey of policies at major research funders found that there is room for more transparency in the process of grant review, which would strengthen the case for the efficiency of public spending on research. On that basis, debate was invited on which transparency measures should be implemented and how, with some concrete suggestions at hand. The present article adds to this discussion by providing further context from the literature, along with considerations on the effect size of the proposed measures. The article then explores the option of opening to the public key components of the process, makes the case for pilot projects in this area, and sketches out the potential that such measures might have to transform the research landscape in those areas in which they are implemented.

  18. Fostering Good Governance at School Level in Honduras: The Role of Transparency Bulletin Boards

    ERIC Educational Resources Information Center

    Boehm, Frédéric; Caprio, Temby

    2014-01-01

    Corruption is at the core of weak governance. In the education sector, corruption is a threat to the quality of and access to education. Although the diagnosis is straightforward, effective reforms are more difficult to implement. The principles of good governance (transparency, participation, accountability, and integrity) provide us guidance,…

  19. Neutronic safety parameters and transient analyses for Poland's MARIA research reactor.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bretscher, M. M.; Hanan, N. A.; Matos, J. E.

    1999-09-27

    Reactor kinetic parameters, reactivity feedback coefficients, and control rod reactivity worths have been calculated for the MARIA Research Reactor (Swierk, Poland) for M6-type fuel assemblies with {sup 235}U enrichments of 80% and 19.7%. Kinetic parameters were evaluated for family-dependent effective delayed neutron fractions, decay constants, and prompt neutron lifetimes and neutron generation times. Reactivity feedback coefficients were determined for fuel Doppler coefficients, coolant (H{sub 2}O) void and temperature coefficients, and for in-core and ex-core beryllium temperature coefficients. Total and differential control rod worths and safety rod worths were calculated for each fuel type. These parameters were used to calculate genericmore » transients for fast and slow reactivity insertions with both HEU and LEU fuels. The analyses show that the HEU and LEU cores have very similar responses to these transients.« less

  20. U-Mo Monolithic Fuel for Nuclear Research and Test Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prabhakaran, Ramprashad

    The metallic fuel selected to replace the current HEU fuels in the research and test reactors is the LEU-10 weight % Mo alloy in the form of a thin sheet or foil encapsulated in AA6061 aluminum alloy with a zirconium interlayer. In order to effectively lead this pursuit, new developments in processing and fabrication of the fuel elements have been initiated, along with a better understanding of material behavior before and after irradiation as a result of these new developments. This editorial note gives an introduction about research and test reactors, need for HEU to LEU conversion, fuel requirements, highmore » uranium density monolithic fuel development and an overview of the four articles published in the December 2017 issue of JOM under a special topic titled “U-Mo Monolithic Fuel for Nuclear Research and Test Reactors”.« less

  1. The MARVEL assembly for neutron multiplication.

    PubMed

    Chichester, David L; Kinlaw, Mathew T

    2013-10-01

    A new multiplying test assembly is under development at Idaho National Laboratory to support research, validation, evaluation, and learning. The item is comprised of three stacked, highly-enriched uranium (HEU) cylinders, each 11.4 cm in diameter and having a combined height of up to 11.7 cm. The combined mass of all three cylinders is 20.3 kg of HEU. Calculations for the bare configuration of the assembly indicate a multiplication level of >3.5 (k(eff)=0.72). Reflected configurations of the assembly, using either polyethylene or tungsten, are possible and have the capability of raising the assembly's multiplication level to greater than 10. This paper describes simulations performed to assess the assembly's multiplication level under different conditions and describes the resources available at INL to support the use of these materials. We also describe some preliminary calculations and test activities using the assembly to study neutron multiplication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Approach to proliferation risk assessment based on multiple objective analysis framework

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrianov, A.; Kuptsov, I.; Studgorodok 1, Obninsk, Kaluga region, 249030

    2013-07-01

    The approach to the assessment of proliferation risk using the methods of multi-criteria decision making and multi-objective optimization is presented. The approach allows the taking into account of the specifics features of the national nuclear infrastructure, and possible proliferation strategies (motivations, intentions, and capabilities). 3 examples of applying the approach are shown. First, the approach has been used to evaluate the attractiveness of HEU (high enriched uranium)production scenarios at a clandestine enrichment facility using centrifuge enrichment technology. Secondly, the approach has been applied to assess the attractiveness of scenarios for undeclared production of plutonium or HEU by theft of materialsmore » circulating in nuclear fuel cycle facilities and thermal reactors. Thirdly, the approach has been used to perform a comparative analysis of the structures of developing nuclear power systems based on different types of nuclear fuel cycles, the analysis being based on indicators of proliferation risk.« less

  3. Processing of LEU targets for {sup 99}Mo production--testing and modification of the Cintichem process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, D.; Landsberger, S.; Buchholz, B.

    1995-09-01

    Recent experimental results on testing and modification of the Cintichem process to allow substitution of low enriched uranium (LEU) for high enriched uranium (HEU) targets are presented in this report. The main focus is on {sup 99}Mo recovery and purification by its precipitation with {alpha}-benzoin oxime. Parameters that were studied include concentrations of nitric and sulfuric acids, partial neutralization of the acids, molybdenum and uranium concentrations, and the ratio of {alpha}-benzoin oxime to molybdenum. Decontamination factors for uranium, neptunium, and various fission products were measured. Experiments with tracer levels of irradiated LEU were conducted for testing the {sup 99}Mo recoverymore » and purification during each step of the Cintichem process. Improving the process with additional processing steps was also attempted. The results indicate that the conversion of molybdenum chemical processing from HEU to LEU targets is possible.« less

  4. Benchmarking of HEU Mental Annuli Critical Assemblies with Internally Reflected Graphite Cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiaobo, Liu; Bess, John D.; Marshall, Margaret A.

    Three experimental configurations of critical assemblies, performed in 1963 at the Oak Ridge Critical Experiment Facility, which are assembled using three different diameter HEU annuli (15-9 inches, 15-7 inches and 13-7 inches) metal annuli with internally reflected graphite cylinder are evaluated and benchmarked. The experimental uncertainties which are 0.00055, 0.00055 and 0.00055 respectively, and biases to the detailed benchmark models which are -0.00179, -0.00189 and -0.00114 respectively, were determined, and the experimental benchmark keff results were obtained for both detailed and simplified model. The calculation results for both detailed and simplified models using MCNP6-1.0 and ENDF VII.1 agree well tomore » the benchmark experimental results with a difference of less than 0.2%. These are acceptable benchmark experiments for inclusion in the ICSBEP Handbook.« less

  5. Highly Conductive Transparent and Flexible Electrodes Including Double-Stacked Thin Metal Films for Transparent Flexible Electronics.

    PubMed

    Han, Jun Hee; Kim, Do-Hong; Jeong, Eun Gyo; Lee, Tae-Woo; Lee, Myung Keun; Park, Jeong Woo; Lee, Hoseung; Choi, Kyung Cheol

    2017-05-17

    To keep pace with the era of transparent and deformable electronics, electrode functions should be improved. In this paper, an innovative structure is suggested to overcome the trade-off between optical and electrical properties that commonly arises with transparent electrodes. The structure of double-stacked metal films showed high conductivity (<3 Ω/sq) and high transparency (∼90%) simultaneously. A proper space between two metal films led to high transmittance by an optical phenomenon. The principle of parallel connection allowed the electrode to have high conductivity. In situ fabrication was possible because the only materials composing the electrode were silver and WO 3 , which can be deposited by thermal evaporation. The electrode was flexible enough to withstand 10 000 bending cycles with a 1 mm bending radius. Furthermore, a few μm scale patterning of the electrode was easily implemented by using photolithography, which is widely employed industrially for patterning. Flexible organic light-emitting diodes and a transparent flexible thin-film transistor were successfully fabricated with the proposed electrode. Various practical applications of this electrode to new transparent flexible electronics are expected.

  6. Creating financial transparency in public health: examining best practices of system partners.

    PubMed

    Honoré, Peggy A; Clarke, Richard L; Mead, Dean Michael; Menditto, Susan M

    2007-01-01

    Financial transparency is based on concepts for valid, standardized information that is readily accessible and routinely disseminated to stakeholders. While Congress and others continuously ask for an accounting of public health investments, transparency remains an ignored concept. The objective of this study was to examine financial transparency practices in other industries considered as part of the public health system. Key informants, regarded as financial experts on the operations of hospitals, school systems, and higher education, were a primary source of information. Principal findings were that system partners have espoused some concepts for financial transparency beginning in the early 20th century--signifying an 80-year implementation gap for public health. Critical features that promote accountability included standardized data collection methods and infrastructures, uniform practices for quantitative analysis of financial performance, and credentialing of the financial management workforce. Recommendations are offered on the basis of these findings to aid public health to close this gap by framing a movement toward transparency.

  7. Child Growth According to Maternal and Child HIV Status in Zimbabwe.

    PubMed

    Omoni, Adetayo O; Ntozini, Robert; Evans, Ceri; Prendergast, Andrew J; Moulton, Lawrence H; Christian, Parul S; Humphrey, Jean H

    2017-09-01

    Growth failure is common among HIV-infected infants, but there are limited data on the effects of HIV exposure or timing of HIV acquisition on growth. Fourteen thousand one hundred ten infants were enrolled in the Zimbabwe Vitamin A for Mothers and Babies trial in Zimbabwe before the availability of antiretroviral therapy or co-trimoxazole. Anthropometric measurements were taken from birth through 12-24 months of age. Growth outcomes were compared between 5 groups of children: HIV-infected in utero (IU), intrapartum (IP) or postnatally (PN); HIV-exposed uninfected (HEU); and HIV unexposed. Growth failure was common across all groups of children. Compared with HIV-unexposed children, IU-, IP- and PN-infected children had significantly lower length-for-age and weight-for-length Z scores throughout the first 2 years of life. At 12 months, odds ratios for stunting were higher in IU [6.25, 95% confidence interval (CI): 4.20-9.31] and IP infants (4.76, 95% CI: 3.58-6.33) than in PN infants (1.70, 95% CI: 1.16-2.47). Compared with HIV-unexposed infants, HEU infants at 12 months had odds ratios for stunting of 1.23 (95% CI: 1.08-1.39) and wasting of 1.56 (95% CI: 1.22-2.00). HIV-infected infants had very high rates of growth failure during the first 2 years of life, particularly if IU or IP infected, highlighting the importance of early infant diagnosis and antiretroviral therapy. HEU infants had poorer growth than HIV-unexposed infants in the first 12 months of life.

  8. Developing a laser shockwave model for characterizing diffusion bonded interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lacy, Jeffrey M., E-mail: Jeffrey.Lacy@inl.gov; Smith, James A., E-mail: Jeffrey.Lacy@inl.gov; Rabin, Barry H., E-mail: Jeffrey.Lacy@inl.gov

    2015-03-31

    The US National Nuclear Security Agency has a Global Threat Reduction Initiative (GTRI) with the goal of reducing the worldwide use of high-enriched uranium (HEU). A salient component of that initiative is the conversion of research reactors from HEU to low enriched uranium (LEU) fuels. An innovative fuel is being developed to replace HEU in high-power research reactors. The new LEU fuel is a monolithic fuel made from a U-Mo alloy foil encapsulated in Al-6061 cladding. In order to support the fuel qualification process, the Laser Shockwave Technique (LST) is being developed to characterize the clad-clad and fuel-clad interface strengthsmore » in fresh and irradiated fuel plates. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves to characterize interfaces in nuclear fuel plates. However, because the deposition of laser energy into the containment layer on a specimen's surface is intractably complex, the shock wave energy is inferred from the surface velocity measured on the backside of the fuel plate and the depth of the impression left on the surface by the high pressure plasma pulse created by the shock laser. To help quantify the stresses generated at the interfaces, a finite element method (FEM) model is being utilized. This paper will report on initial efforts to develop and validate the model by comparing numerical and experimental results for back surface velocities and front surface depressions in a single aluminum plate representative of the fuel cladding.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Margaret A. Marshall; John D. Bess; Yevgeniy Rozhikhin

    In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared withmore » the GODIVA I experiments[1]. Part of the experimental series was the measurement of the delayed neutron fraction, ßeff, using time correlation measurements and using the central void reactivity measurement. The time correlations measurements were rejected by the experimenter. The measurements using the central void reactivity measurement yielded a ßeff value of 0.00657, which agrees well with the value measured with GODIVA I (0.0066). This measurement is evaluated, found to be acceptable, and discussed in extensive detail in “ORSphere: Physics Measurements for Bare, HEU(93.2) Metal Sphere”[2]. In order to determine the delayed neutron fraction using the central void reactivity delayed neutron parameters must be used. The experimenter utilized the delayed neutron parameters set forth by Keepin, Wimment, and Zeigler[3]. If the derivation of the ßeff is repeated with different delayed neutron parameters from various modern nuclear data sets the resulting values vary greatly from the expected results.« less

  10. Leukocyte Telomere Length in HIV-Infected and HIV-Exposed Uninfected Children: Shorter Telomeres with Uncontrolled HIV Viremia

    PubMed Central

    Côté, Hélène C. F.; Soudeyns, Hugo; Thorne, Anona; Alimenti, Ariane; Lamarre, Valérie; Maan, Evelyn J.; Sattha, Beheroze; Singer, Joel; Lapointe, Normand; Money, Deborah M.; Forbes, John

    2012-01-01

    Objectives Nucleoside reverse transcriptase inhibitors (NRTIs) used in HIV antiretroviral therapy can inhibit human telomerase reverse transcriptase. We therefore investigated whether in utero or childhood exposure to NRTIs affects leukocyte telomere length (LTL), a marker of cellular aging. Methods In this cross-sectional CARMA cohort study, we investigated factors associated with LTL in HIV -1-infected (HIV+) children (n = 94), HIV-1-exposed uninfected (HEU) children who were exposed to antiretroviral therapy (ART) perinatally (n = 177), and HIV-unexposed uninfected (HIV−) control children (n = 104) aged 0–19 years. Univariate followed by multivariate linear regression models were used to examine relationships of explanatory variables with LTL for: a) all subjects, b) HIV+/HEU children only, and c) HIV+ children only. Results After adjusting for age and gender, there was no difference in LTL between the 3 groups, when considering children of all ages together. In multivariate models, older age and male gender were associated with shorter LTL. For the HIV+ group alone, having a detectable HIV viral load was also strongly associated with shorter LTL (p = 0.007). Conclusions In this large study, group rates of LTL attrition were similar for HIV+, HEU and HIV− children. No associations between children’s LTL and their perinatal ART exposure or HIV status were seen in linear regression models. However, the association between having a detectable HIV viral load and shorter LTL suggests that uncontrolled HIV viremia rather than duration of ART exposure may be associated with acceleration of blood telomere attrition. PMID:22815702

  11. A Stochastic Imaging Technique for Spatio-Spectral Characterization of Special Nuclear Material

    NASA Astrophysics Data System (ADS)

    Hamel, Michael C.

    Radiation imaging is advantageous for detecting, locating and characterizing special nuclear material (SNM) in complex environments. A dual-particle imager (DPI) has been designed that is capable of detecting gamma-ray and neutron signatures from shielded SNM. The system combines liquid organic and NaI(Tl) scintillators to form a combined Compton and neutron scatter camera. Effective image reconstruction of detected particles is a crucial component for maximizing the performance of the system; however, a key deficiency exists in the widely used list-mode maximum-likelihood estimation-maximization (MLEM) image reconstruction technique. The steady-state solution produced by this iterative method will have poor quality compared to solutions produced with fewer iterations. A stopping condition is required to achieve a better solution but these conditions fail to achieve maximum image quality. Stochastic origin ensembles (SOE) imaging is a good candidate to address this problem as it uses Markov chain Monte Carlo to reach a stochastic steady-state solution that has image quality comparable to the best MLEM solution. The application of SOE to the DPI is presented in this work. SOE was originally applied in medical imaging applications with no mechanism to isolate spectral information based on location. This capability is critical for non-proliferation applications as complex radiation environments with multiple sources are often encountered. This dissertation extends the SOE algorithm to produce spatially dependent spectra and presents experimental result showing that the technique was effective for isolating a 4.1-kg mass of weapons grade plutonium (WGPu) when other neutron and gamma-ray sources were present. This work also demonstrates the DPI as an effective tool for localizing and characterizing highly enriched uranium (HEU). A series of experiments were performed with the DPI using a deuterium-deuterium (DD) and deuterium-tritium (DT) neutron generator, as well as AmLi, to interrogate a 13.7-kg sphere of HEU. In all cases, the neutrons and gamma rays produced from induced fission were successfully discriminated from the interrogating particles to localize the HEU. For characterization, the fast neutron and gamma-ray spectra were recorded from multiple HEU configurations with low-Z and high-Z moderation. Further characterization of the configurations used the measured neutron lifetime to show that the DPI can be used to infer multiplication.

  12. Performance of europium-doped strontium iodide, transparent ceramics and bismuth-loaded polymer scintillators

    NASA Astrophysics Data System (ADS)

    Cherepy, N. J.; Payne, S. A.; Sturm, B. W.; O'Neal, S. P.; Seeley, Z. M.; Drury, O. B.; Haselhorst, L. K.; Rupert, B. L.; Sanner, R. D.; Thelin, P. A.; Fisher, S. E.; Hawrami, R.; Shah, K. S.; Burger, A.; Ramey, J. O.; Boatner, L. A.

    2011-09-01

    Recently discovered scintillators for gamma ray spectroscopy - single-crystal SrI2(Eu), GYGAG(Ce) transparent ceramic and Bismuth-loaded plastics - offer resolution and fabrication advantages compared to commercial scintillators, such as NaI(Tl) and standard PVT plastic. Energy resolution at 662 keV of 2.7% is obtained with SrI2(Eu), while 4.5% is obtained with GYGAG(Ce). A new transparent ceramic scintillator for radiographic imaging systems, GLO(Eu), offers high light yield of 70,000 Photons/MeV, high stopping, and low radiation damage. Implementation of single-crystal SrI2(Eu), Gd-based transparent ceramics, and Bi-loaded plastic scintillators can advance the state-of-the art in ionizing radiation detection systems.

  13. Transparent actuator made with few layer graphene electrode and dielectric elastomer, for variable focus lens

    NASA Astrophysics Data System (ADS)

    Hwang, Taeseon; Kwon, Hyeok-Yong; Oh, Joon-Suk; Hong, Jung-Pyo; Hong, Seung-Chul; Lee, Youngkwan; Ryeol Choi, Hyouk; Jin Kim, Kwang; Hossain Bhuiya, Mainul; Nam, Jae-Do

    2013-07-01

    A transparent dielectric elastomer actuator driven by few-layer-graphene (FLG) electrode was experimentally investigated. The electrodes were made of graphene, which was dispersed in N-methyl-pyrrolidone. The transparent actuator was fabricated from developed FLG electrodes. The FLG electrode with its sheet resistance of 0.45 kΩ/sq (80 nm thick) was implemented to mask silicone elastomer. The developed FLG-driven actuator exhibited an optical transparency of over 57% at a wavenumber of 600 nm and produced bending displacement performance ranging from 29 to 946 μm as functions of frequency and voltage. The focus variation was clearly demonstrated under actuation to study its application-feasibility in variable focus lens and various opto-electro-mechanical devices.

  14. Performance of Europium-Doped Strontium Iodide, Transparent Ceramics and Bismuth-loaded Polymer Scintillators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cherepy, N J; Payne, S A; Sturm, B W

    2011-08-30

    Recently discovered scintillators for gamma ray spectroscopy, single crystal SrI{sub 2}(Eu), GYGAG(Ce) transparent ceramic and Bismuth-loaded plastics, offer resolution and fabrication advantages compared to commercial scintillators, such as NaI(Tl) and standard PVT plastic. Energy resolution at 662 keV of 2.7% is obtained with SrI{sub 2}(Eu), while 4.5% is obtained with GYGAG(Ce). A new transparent ceramic scintillator for radiographic imaging systems, GLO(Eu) offers high light yield of 70,000 Photons/MeV, high stopping, and low radiation damage. Implementation of single crystal SrI{sub 2}(Eu), Gd-based transparent ceramics, and Bi-loaded plastic scintillators can advance the state-of-the art in ionizing radiation detection systems.

  15. Notification: Lessons Learned from Implementing the American Recovery and Reinvestment Act of 2009 (Recovery Act)

    EPA Pesticide Factsheets

    Project #OA-FY12-0360, March 5, 2012. The Recovery Funds Working Group of the Recovery Accountability and Transparency Board has initiated a project to capture lessons learned from Recovery Act implementation.

  16. Clean Water Act (CWA) Action Plan Implementation Priorities: Changes to Improve Water Quality, Increase Compliance and Expand Transparency

    EPA Pesticide Factsheets

    The Clean Water Act (CWA) Action Plan Implementation Priorities describes the new approaches to revamp the National Pollutant Discharge Elimination System (NPDES) permitting, compliance and enforcement program.Issued May 11, 2011

  17. A STATE DEMONSTRATION AND EVALUATION IN DEVELOPING PILOT OVERHEAD TRANSPARENCIES FOR THE SUBJECT AREAS OF SECONDARY SCIENCE, MATHEMATICS, ENGLISH, MODERN FOREIGN LANGUAGES, AND GEOGRAPHY.

    ERIC Educational Resources Information Center

    KINNIELL, WILLIAM T.; AND OTHERS

    A DEMONSTRATION PROGRAM WAS UNDERTAKEN FOR THE PURPOSE OF SHOWING HOW A STATE DEPARTMENT OF EDUCATION CAN UTILIZE ITS RESOURCES AND SUBJECT MATTER SPECIALISTS IN DEVELOPING OVERHEAD TRANSPARENCIES TO IMPLEMENT SECONDARY SCHOOL CURRICULUM IN THE STATE. SUBJECT SPECIALISTS (26) REPRESENTING 10 COURSE FIELDS WERE BROUGHT TOGETHER AT THE BEGINNING OF…

  18. Content-based image retrieval in medical applications for picture archiving and communication systems

    NASA Astrophysics Data System (ADS)

    Lehmann, Thomas M.; Guld, Mark O.; Thies, Christian; Fischer, Benedikt; Keysers, Daniel; Kohnen, Michael; Schubert, Henning; Wein, Berthold B.

    2003-05-01

    Picture archiving and communication systems (PACS) aim to efficiently provide the radiologists with all images in a suitable quality for diagnosis. Modern standards for digital imaging and communication in medicine (DICOM) comprise alphanumerical descriptions of study, patient, and technical parameters. Currently, this is the only information used to select relevant images within PACS. Since textual descriptions insufficiently describe the great variety of details in medical images, content-based image retrieval (CBIR) is expected to have a strong impact when integrated into PACS. However, existing CBIR approaches usually are limited to a distinct modality, organ, or diagnostic study. In this state-of-the-art report, we present first results implementing a general approach to content-based image retrieval in medical applications (IRMA) and discuss its integration into PACS environments. Usually, a PACS consists of a DICOM image server and several DICOM-compliant workstations, which are used by radiologists for reading the images and reporting the findings. Basic IRMA components are the relational database, the scheduler, and the web server, which all may be installed on the DICOM image server, and the IRMA daemons running on distributed machines, e.g., the radiologists" workstations. These workstations can also host the web-based front-ends of IRMA applications. Integrating CBIR and PACS, a special focus is put on (a) location and access transparency for data, methods, and experiments, (b) replication transparency for methods in development, (c) concurrency transparency for job processing and feature extraction, (d) system transparency at method implementation time, and (e) job distribution transparency when issuing a query. Transparent integration will have a certain impact on diagnostic quality supporting both evidence-based medicine and case-based reasoning.

  19. Malaria illness mediated by anaemia lessens cognitive development in younger Ugandan children.

    PubMed

    Boivin, Michael J; Sikorskii, Alla; Familiar-Lopez, Itziar; Ruiseñor-Escudero, Horacio; Muhindo, Mary; Kapisi, James; Bigira, Victor; Bass, Judy K; Opoka, Robert O; Nakasujja, Noeline; Kamya, Moses; Dorsey, Grant

    2016-04-14

    Asymptomatic falciparum malaria is associated with poorer cognitive performance in African schoolchildren and intermittent preventive treatment of malaria improves cognitive outcomes. However, the developmental benefits of chemoprevention in early childhood are unknown. Early child development was evaluated as a major outcome in an open-label, randomized, clinical trial of anti-malarial chemoprevention in an area of intense, year-round transmission in Uganda. Infants were randomized to one of four treatment arms: no chemoprevention, daily trimethoprim-sulfamethoxazole, monthly sulfadoxine-pyrimethamine, or monthly dihydroartemisinin-piperaquine (DP), to be given between enrollment (4-6 mos) and 24 months of age. Number of malaria episodes, anaemia (Hb < 10) and neurodevelopment [Mullen Scales of Early Learning (MSEL)] were assessed at 2 years (N = 469) and at 3 years of age (N = 453); at enrollment 70 % were HIV-unexposed uninfected (HUU) and 30 % were HIV-exposed uninfected (HEU). DP was highly protective against malaria and anaemia, although trial arm was not associated with MSEL outcomes. Across all treatment arms, episodes of malarial illness were negatively predictive of MSEL cognitive performance both at 2 and 3 years of age (P = 0.02). This relationship was mediated by episodes of anaemia. This regression model was stronger for the HEU than for the HUU cohort. Compared to HUU, HEU was significantly poorer on MSEL receptive language development irrespective of malaria and anaemia (P = 0.01). Malaria with anaemia and HIV exposure are significant risk factors for poor early childhood neurodevelopment in malaria-endemic areas in rural Africa. Because of this, comprehensive and cost/effective intervention is needed for malaria prevention in very young children in these settings.

  20. Cardiac Biomarkers in HIV-Exposed Uninfected Children: The Pediatric HIV/AIDS Cohort Study (PHACS)

    PubMed Central

    WILKINSON, James D.; WILLIAMS, Paige L.; LEISTER, Erin; ZELDOW, Bret; SHEARER, William T.; COLAN, Steven D.; SIBERRY, George K.; DOOLEY, Laurie B.; SCOTT, Gwendolyn B.; RICH, Kenneth C.; LIPSHULTZ, Steven E.

    2014-01-01

    Objectives To evaluate associations of cardiac biomarkers with in utero antiretroviral (ARV) drug exposures and cardiac function/structure measured by echocardiograms in HIV-exposed but uninfected (HEU) children. Design and methods We analyzed the association of three cardiac biomarkers (cardiac troponin T, cTnT; high sensitivity C-reactive protein, hsCRP; and N-terminal pro-brain natriuretic peptide, NT-proBNP) with prenatal ARV exposures, maternal-child characteristics, and echocardiographic parameters. Results Among 338 HEU children (mean age=4.3 years), 51% had at least 1 elevated cardiac biomarker. Maternal tobacco use was associated with elevated NT-proBNP (adjusted odds ratio [aOR]=2.28, P=0.02). Maternal alcohol and abacavir use were associated with elevated cTnT levels (aOR=3.56, P=0.01 and aOR=2.33, P=0.04, respectively). Among 94 children with paired echocardiogram-biomarker measurements, cTnT measurements were correlated with increased left ventricular (LV) thickness-to-dimension ratio (r=0.21, P=0.04); and elevated cTnT was associated with higher mean LV end-diastolic (ED) posterior wall thickness (P=0.04). hsCRP measurements were negatively correlated with septal thickness (r=-0.22, P=0.03) and elevated hsCRP was associated with lower mean LV contractility Z-scores (P=0.04). NT-proBNP measurements were correlated with increased LVED dimension (r=0.20, P=0.05) and elevated NT-proBNP was associated with lower mean end-systolic septal thickness (P=0.03). Conclusion Our findings suggest that cardiac biomarkers may help identify HEU children who require further cardiac evaluation including echocardiography. Potential cardiac effects of prenatal abacavir exposure in this population need further investigation. PMID:23211773

  1. Contribution of Maternal Antiretroviral Therapy and Breastfeeding to 24-Month Survival in Human Immunodeficiency Virus-Exposed Uninfected Children: An Individual Pooled Analysis of African and Asian Studies.

    PubMed

    Arikawa, Shino; Rollins, Nigel; Jourdain, Gonzague; Humphrey, Jean; Kourtis, Athena P; Hoffman, Irving; Essex, Max; Farley, Tim; Coovadia, Hoosen M; Gray, Glenda; Kuhn, Louise; Shapiro, Roger; Leroy, Valériane; Bollinger, Robert C; Onyango-Makumbi, Carolyne; Lockman, Shahin; Marquez, Carina; Doherty, Tanya; Dabis, François; Mandelbrot, Laurent; Le Coeur, Sophie; Rolland, Matthieu; Joly, Pierre; Newell, Marie-Louise; Becquet, Renaud

    2018-05-17

    Human immunodeficiency virus (HIV)-infected pregnant women increasingly receive antiretroviral therapy (ART) to prevent mother-to-child transmission (PMTCT). Studies suggest HIV-exposed uninfected (HEU) children face higher mortality than HIV-unexposed children, but most evidence relates to the pre-ART era, breastfeeding of limited duration, and considerable maternal mortality. Maternal ART and prolonged breastfeeding while on ART may improve survival, although this has not been reliably quantified. Individual data on 19 219 HEU children from 21 PMTCT trials/cohorts undertaken from 1995 to 2015 in Africa and Asia were pooled to estimate the association between 24-month mortality and maternal/infant factors, using random-effects Cox proportional hazards models. Adjusted attributable fractions of risks computed using the predict function in the R package "frailtypack" were used to estimate the relative contribution of risk factors to overall mortality. Cumulative incidence of death was 5.5% (95% confidence interval, 5.1-5.9) by age 24 months. Low birth weight (LBW <2500 g, adjusted hazard ratio (aHR, 2.9), no breastfeeding (aHR, 2.5), and maternal death (aHR, 11.1) were significantly associated with increased mortality. Maternal ART (aHR, 0.5) was significantly associated with lower mortality. At the population level, LBW accounted for 16.2% of 24-month mortality, never breastfeeding for 10.8%, mother not receiving ART for 45.6%, and maternal death for 4.3%; combined, these factors explained 63.6% of deaths by age 24 months. Survival of HEU children could be substantially improved if public health practices provided all HIV-infected mothers with ART and supported optimal infant feeding and care for LBW neonates.

  2. Calculation and comparison of xenon and samarium reactivities of the HEU, LEU core in the low power research reactor.

    PubMed

    Dawahra, S; Khattab, K; Saba, G

    2015-07-01

    Comparative studies for the conversion of the fuel from HEU to LEU in the Miniature Neutron Source Reactor (MNSR) have been performed using the MCNP4C and GETERA codes. The precise calculations of (135)Xe and (149)Sm concentrations and reactivities were carried out and compared during the MNSR operation time and after shutdown for the existing HEU fuel (UAl4-Al, 90% enriched) and the potential LEU fuels (U3Si2-Al, U3Si-Al, U9Mo-Al, 19.75% enriched and UO2, 12.6% enriched) in this paper using the MCNP4C and GETERA codes. It was found that the (135)Xe and (149)Sm reactivities did not reach their equilibrium reactivities during the daily operating time of the reactor. The (149)Sm reactivities could be neglected compared to (135)Xe reactivities during the reactor operating time and after shutdown. The calculations for the UAl4-Al produced the highest (135)Xe reactivity in all the studied fuel group during the reactor operation (0.39 mk) and after the reactor shutdown (0.735 mk), It followed by U3Si-Al (0.34 mk, 0.653 mk), U3Si2-Al (0.33 mk, 0.634 mk), U9Mo-Al (0.3 mk, 0.568 mk) and UO2 (0.24 mk, 0.448 mk) fuels, respectively. Finally, the results showed that the UO2 was the best candidate for fuel conversion to LEU in the MNSR since it gave the lowest (135)Xe reactivity during the reactor operation and after shutdown. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Estimate of radiation release from MIT reactor with un-finned LEU core during Maximum Hypothetical Accident

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Kaichao; Hu, Lin-wen; Newton, Thomas

    2017-05-01

    The Massachusetts Institute of Technology Reactor (MITR-II) is a research reactor in Cambridge, Massachusetts designed primarily for experiments using neutron beam and in-core irradiation facilities. At 6 MW, it delivers neutron flux and energy spectrum comparable to light water reactor (LWR) power reactors in a compact core using highly enriched uranium (HEU) fuel. In the framework of nonproliferation policy, the international community aims to minimize the use of HEU in civilian facilities. Within this context, research and test reactors have started a program to convert HEU fuel to low enriched uranium (LEU) fuel. A new type of LEU fuel basedmore » on a high density alloy of uranium and molybdenum (U-10Mo) is expected to allow the conversion of U.S. domestic high performance reactors like MITR. The current study focuses on the impacts of MITR Maximum Hypothetical Accident (MHA), which is also the Design Basis Accident (DBA), with LEU fuel. The MHA for the MITR is postulated to be a coolant flow blockage in the fuel element that contains the hottest fuel plate. It is assumed that the entire active portion of five fuel plates melts. The analysis shows that, within a 2-h period and by considering all the possible radiation sources and dose pathways, the overall off-site dose is 302.1 mrem (1 rem ¼ 0.01 Sv) Total Effective Dose Equivalent (TEDE) at 8 m exclusion area boundary (EAB) and a higher dose of 392.8 mrem TEDE is found at 21 m EAB. In all cases the dose remains below the 500 mrem total TEDE limit goal based on NUREG-1537 guidelines.« less

  4. Head circumferences of children born to HIV-infected and HIV-uninfected mothers in Zimbabwe during the preantiretroviral therapy era

    PubMed Central

    Evans, Ceri; Chasekwa, Bernard; Ntozini, Robert; Humphrey, Jean H.; Prendergast, Andrew J.

    2016-01-01

    Objectives: To describe the head growth of children according to maternal and child HIV infection status. Design: Longitudinal analysis of head circumference data from 13 647 children followed from birth in the ZVITAMBO trial, undertaken in Harare, Zimbabwe, between 1997 and 2001, prior to availability of antiretroviral therapy (ART) or cotrimoxazole prophylaxis. Methods: Head circumference was measured at birth, then at regular intervals through 24 months of age. Mean head circumference-for-age Z-scores (HCZ) and prevalence of microcephaly (HCZ < −2) were compared between HIV-unexposed children, HIV-exposed uninfected (HEU) children and children infected with HIV in utero (IU), intrapartum (IP) and postnatally (PN). Results: Children infected with HIV in utero had head growth restriction at birth. Head circumference Z-scores remained low throughout follow-up in IP children, whereas they progressively declined in IU children. During the second year of life, HCZ in the PN group declined, reaching a similar mean as IP-infected children by 21 months of age. Microcephaly was more common among IU and IP children than HIV-uninfected children through 24 months. HEU children had significantly lower head circumferences than HIV-unexposed children through 12 months. Conclusion: HIV-infected children had lower head circumferences and more microcephaly than HIV-uninfected children. Timing of HIV acquisition; influenced HCZ, with those infected before birth having particularly poor head growth. HEU children had poorer head growth until 12 months of age. Correlations between head growth and neurodevelopment in the context of maternal/infant HIV infection, and further studies from the current ART era, will help determine the predictive value of routine head circumference measurement. PMID:27428746

  5. Time-correlated neutron analysis of a multiplying HEU source

    NASA Astrophysics Data System (ADS)

    Miller, E. C.; Kalter, J. M.; Lavelle, C. M.; Watson, S. M.; Kinlaw, M. T.; Chichester, D. L.; Noonan, W. A.

    2015-06-01

    The ability to quickly identify and characterize special nuclear material remains a national security challenge. In counter-proliferation applications, identifying the neutron multiplication of a sample can be a good indication of the level of threat. Currently neutron multiplicity measurements are performed with moderated 3He proportional counters. These systems rely on the detection of thermalized neutrons, a process which obscures both energy and time information from the source. Fast neutron detectors, such as liquid scintillators, have the ability to detect events on nanosecond time scales, providing more information on the temporal structure of the arriving signal, and provide an alternative method for extracting information from the source. To explore this possibility, a series of measurements were performed on the Idaho National Laboratory's MARVEL assembly, a configurable HEU source. The source assembly was measured in a variety of different HEU configurations and with different reflectors, covering a range of neutron multiplications from 2 to 8. The data was collected with liquid scintillator detectors and digitized for offline analysis. A gap based approach for identifying the bursts of detected neutrons associated with the same fission chain was used. Using this approach, we are able to study various statistical properties of individual fission chains. One of these properties is the distribution of neutron arrival times within a given burst. We have observed two interesting empirical trends. First, this distribution exhibits a weak, but definite, dependence on source multiplication. Second, there are distinctive differences in the distribution depending on the presence and type of reflector. Both of these phenomena might prove to be useful when assessing an unknown source. The physical origins of these phenomena can be illuminated with help of MCNPX-PoliMi simulations.

  6. Cardiac biomarkers in HIV-exposed uninfected children.

    PubMed

    Wilkinson, James D; Williams, Paige L; Leister, Erin; Zeldow, Bret; Shearer, William T; Colan, Steven D; Siberry, George K; Dooley, Laurie B; Scott, Gwendolyn B; Rich, Kenneth C; Lipshultz, Steven E

    2013-04-24

    To evaluate associations of cardiac biomarkers with in-utero antiretroviral drug exposures and cardiac function/structure measured by echocardiograms in HIV-exposed but uninfected (HEU) children. We analyzed the association of three cardiac biomarkers (cardiac troponin T, cTnT; high sensitivity C-reactive protein, hsCRP; and N-terminal pro-brain natriuretic peptide, NT-proBNP) with prenatal antiretroviral drug exposures, maternal-child characteristics, and echocardiographic parameters. Among 338 HEU children (mean age 4.3 years), 51% had at least one elevated cardiac biomarker. Maternal tobacco use was associated with elevated NT-proBNP [adjusted odds ratio (aOR) 2.28, P=0.02]. Maternal alcohol and abacavir use were associated with elevated cTnT levels (aOR 3.56, P=0.01 and aOR 2.33, P=0.04, respectively). Among 94 children with paired echocardiogram-biomarker measurements, cTnT measurements were correlated with increased left-ventricular thickness-to-dimension ratio (r=0.21, P=0.04); and elevated cTnT was associated with higher mean left-ventricular end-diastolic (LVED) posterior wall thickness (P=0.04). hsCRP measurements were negatively correlated with septal thickness (r=-0.22, P=0.03) and elevated hsCRP was associated with lower mean left-ventricular contractility Z-scores (P=0.04). NT-proBNP measurements were correlated with increased LVED dimension (r=0.20, P=0.05) and elevated NT-proBNP was associated with lower mean end-systolic septal thickness (P=0.03). Our findings suggest that cardiac biomarkers may help identify HEU children who require further cardiac evaluation including echocardiography. Potential cardiac effects of prenatal abacavir exposure in this population need further investigation.

  7. Local Burn-Up Effects in the NBSR Fuel Element

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown N. R.; Hanson A.; Diamond, D.

    2013-01-31

    This study addresses the over-prediction of local power when the burn-up distribution in each half-element of the NBSR is assumed to be uniform. A single-element model was utilized to quantify the impact of axial and plate-wise burn-up on the power distribution within the NBSR fuel elements for both high-enriched uranium (HEU) and low-enriched uranium (LEU) fuel. To validate this approach, key parameters in the single-element model were compared to parameters from an equilibrium core model, including neutron energy spectrum, power distribution, and integral U-235 vector. The power distribution changes significantly when incorporating local burn-up effects and has lower power peakingmore » relative to the uniform burn-up case. In the uniform burn-up case, the axial relative power peaking is over-predicted by as much as 59% in the HEU single-element and 46% in the LEU single-element with uniform burn-up. In the uniform burn-up case, the plate-wise power peaking is over-predicted by as much as 23% in the HEU single-element and 18% in the LEU single-element. The degree of over-prediction increases as a function of burn-up cycle, with the greatest over-prediction at the end of Cycle 8. The thermal flux peak is always in the mid-plane gap; this causes the local cumulative burn-up near the mid-plane gap to be significantly higher than the fuel element average. Uniform burn-up distribution throughout a half-element also causes a bias in fuel element reactivity worth, due primarily to the neutronic importance of the fissile inventory in the mid-plane gap region.« less

  8. Design, implementation and reporting strategies to reduce the instance and impact of missing patient-reported outcome (PRO) data: a systematic review

    PubMed Central

    Mercieca-Bebber, Rebecca; Palmer, Michael J; Brundage, Michael; Stockler, Martin R; King, Madeleine T

    2016-01-01

    Objectives Patient-reported outcomes (PROs) provide important information about the impact of treatment from the patients' perspective. However, missing PRO data may compromise the interpretability and value of the findings. We aimed to report: (1) a non-technical summary of problems caused by missing PRO data; and (2) a systematic review by collating strategies to: (A) minimise rates of missing PRO data, and (B) facilitate transparent interpretation and reporting of missing PRO data in clinical research. Our systematic review does not address statistical handling of missing PRO data. Data sources MEDLINE and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases (inception to 31 March 2015), and citing articles and reference lists from relevant sources. Eligibility criteria English articles providing recommendations for reducing missing PRO data rates, or strategies to facilitate transparent interpretation and reporting of missing PRO data were included. Methods 2 reviewers independently screened articles against eligibility criteria. Discrepancies were resolved with the research team. Recommendations were extracted and coded according to framework synthesis. Results 117 sources (55% discussion papers, 26% original research) met the eligibility criteria. Design and methodological strategies for reducing rates of missing PRO data included: incorporating PRO-specific information into the protocol; carefully designing PRO assessment schedules and defining termination rules; minimising patient burden; appointing a PRO coordinator; PRO-specific training for staff; ensuring PRO studies are adequately resourced; and continuous quality assurance. Strategies for transparent interpretation and reporting of missing PRO data include utilising auxiliary data to inform analysis; transparently reporting baseline PRO scores, rates and reasons for missing data; and methods for handling missing PRO data. Conclusions The instance of missing PRO data and its potential to bias clinical research can be minimised by implementing thoughtful design, rigorous methodology and transparent reporting strategies. All members of the research team have a responsibility in implementing such strategies. PMID:27311907

  9. Evaluation of a uranium zirconium hydride fuel rod option for conversion of the MIT research reactor (MITR) from highly-enriched uranium to low-enriched uranium

    DOE PAGES

    Dunn, F. E.; Wilson, E. H.; Feldman, E. E.; ...

    2017-03-23

    The conversion of the Massachusetts Institute of Technology Reactor (MITR) from the use of highly-enriched uranium (HEU) fuel-plate assemblies to low-enriched uranium (LEU) by replacing the HEU fuel plates with specially designed General Atomics (GA) uranium zirconium hydride (UZrH) LEU fuel rods is evaluated in this paper. The margin to critical heat flux (CHF) in the core, which is cooled by light water at low pressure, is evaluated analytically for steady-state operation. A form of the Groeneveld CHF lookup table method is used and described in detail. A CHF ratio of 1.41 was found in the present analysis at 10more » MW with engineering hot channel factors included. Therefore, the nominal reactor core power, and neutron flux performance, would need to be reduced by at least 25% in order to meet the regulatory requirement of a minimum CHF ratio of 2.0.« less

  10. Evaluation of a uranium zirconium hydride fuel rod option for conversion of the MIT research reactor (MITR) from highly-enriched uranium to low-enriched uranium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunn, F. E.; Wilson, E. H.; Feldman, E. E.

    The conversion of the Massachusetts Institute of Technology Reactor (MITR) from the use of highly-enriched uranium (HEU) fuel-plate assemblies to low-enriched uranium (LEU) by replacing the HEU fuel plates with specially designed General Atomics (GA) uranium zirconium hydride (UZrH) LEU fuel rods is evaluated in this paper. The margin to critical heat flux (CHF) in the core, which is cooled by light water at low pressure, is evaluated analytically for steady-state operation. A form of the Groeneveld CHF lookup table method is used and described in detail. A CHF ratio of 1.41 was found in the present analysis at 10more » MW with engineering hot channel factors included. Therefore, the nominal reactor core power, and neutron flux performance, would need to be reduced by at least 25% in order to meet the regulatory requirement of a minimum CHF ratio of 2.0.« less

  11. IER-297 CED-2: Final Design for Thermal/Epithermal eXperiments with Jemima Plates with Polyethylene and Hafnium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, A. J.; Percher, C. M.; Zywiec, W. J.

    This report presents the final design (CED-2) for IER-297, and focuses on 15 critical configurations using highly enriched uranium (HEU) Jemima plates moderated by polyethylene with and without hafnium diluent. The goal of the U.S. Nuclear Criticality Safety Program’s Thermal/Epithermal eXperiments (TEX) is to design and conduct new critical experiments to address high priority nuclear data needs from the nuclear criticality safety and nuclear data communities, with special emphasis on intermediate energy (0.625 eV – 100 keV) assemblies that can be easily modified to include various high priority diluent materials. The TEX (IER 184) CED-1 Report [1], completed in 2012,more » demonstrated the feasibility of meeting the TEX goals with two existing NCSP fissile assets, plutonium Zero Power Physics Reactor (ZPPR) plates and highly enriched uranium (HEU) Jemima plates. The first set of TEX experiments will focus on using the plutonium ZPPR plates with polyethylene moderator and tantalum diluents.« less

  12. High-temperature Gas Reactor (HTGR)

    NASA Astrophysics Data System (ADS)

    Abedi, Sajad

    2011-05-01

    General Atomics (GA) has over 35 years experience in prismatic block High-temperature Gas Reactor (HTGR) technology design. During this period, the design has recently involved into a modular have been performed to demonstrate its versatility. This versatility is directly related to refractory TRISO coated - particle fuel that can contain any type of fuel. This paper summarized GA's fuel cycle studies individually and compares each based upon its cycle sustainability, proliferation-resistance capabilities, and other performance data against pressurized water reactor (PWR) fuel cycle data. Fuel cycle studies LEU-NV;commercial HEU-Th;commercial LEU-Th;weapons-grade plutonium consumption; and burning of LWR waste including plutonium and minor actinides in the MHR. results show that all commercial MHR options, with the exception of HEU-TH, are more sustainable than a PWR fuel cycle. With LEU-NV being the most sustainable commercial options. In addition, all commercial MHR options out perform the PWR with regards to its proliferation-resistance, with thorium fuel cycle having the best proliferation-resistance characteristics.

  13. Through-transmission laser welding of glass fibre composite: Experimental light scattering identification

    NASA Astrophysics Data System (ADS)

    Cosson, Benoit; Asséko, André Chateau Akué; Dauphin, Myriam

    2018-05-01

    The purpose of this paper is to develop a cost-effective, efficient and quick to implement experimental optical method in order to predict the optical properties (extinction coefficient) of semi-transparent polymer composites. The extinction coefficient takes into account the effects due to the absorption and the scattering phenomena in a semi-transparent component during the laser processes, i.e. TTLW (through-transmission laser welding). The present method used a laser as light source and a reflex camera equipped with a macro lens as a measurement device and is based on the light transmission measurement through different thickness samples. The interaction between the incident laser beam and the semi-transparent composite is exanimated. The results are presented for the case of a semi-transparent composite reinforced with the unidirectional glass fiber (UD). A numerical method, ray tracing, is used to validate the experimental results. The ray tracing method is appropriate to characterize the light-scattering phenomenon in semi-transparent materials.

  14. Trials, tricks and transparency: how disclosure rules affect clinical knowledge.

    PubMed

    Dahm, Matthias; González, Paula; Porteiro, Nicolás

    2009-12-01

    Scandals of selective reporting of clinical trial results by pharmaceutical firms have underlined the need for more transparency in clinical trials. We provide a theoretical framework which reproduces incentives for selective reporting and yields three key implications concerning regulation. First, a compulsory clinical trial registry complemented through a voluntary clinical trial results database can implement full transparency (the existence of all trials as well as their results is known). Second, full transparency comes at a price. It has a deterrence effect on the incentives to conduct clinical trials, as it reduces the firms' gains from trials. Third, in principle, a voluntary clinical trial results database without a compulsory registry is a superior regulatory tool; but we provide some qualified support for additional compulsory registries when medical decision-makers cannot anticipate correctly the drug companies' decisions whether to conduct trials.

  15. Investigating the Defect Structures in Transparent Conducting Oxides Using X-ray and Neutron Scattering Techniques

    PubMed Central

    González, Gabriela B.

    2012-01-01

    Transparent conducting oxide (TCO) materials are implemented into a wide variety of commercial devices because they possess a unique combination of high optical transparency and high electrical conductivity. Created during the processing of the TCOs, defects within the atomic-scale structure are responsible for their desirable optical and electrical properties. Therefore, studying the defect structure is essential to a better understanding of the behavior of transparent conductors. X-ray and neutron scattering techniques are powerful tools to investigate the atomic lattice structural defects in these materials. This review paper presents some of the current developments in the study of structural defects in n-type TCOs using x-ray diffraction (XRD), neutron diffraction, extended x-ray absorption fine structure (EXAFS), pair distribution functions (PDFs), and x-ray fluorescence (XRF). PMID:28817010

  16. 77 FR 4807 - Revised Fee Policy for Acceptance of Foreign Research Reactor Spent Nuclear Fuel From High-Income...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-31

    ...This notice announces a change in the fee policy by the Department of Energy (DOE) for receipt and management of spent nuclear fuel (SNF) from foreign research reactors (FRR) containing uranium enriched in the U.S. in countries with high-income economies, as identified in the World Bank Development Report. The fee will increase in three phases (See Table 1) for all future SNF shipments (including Training, Research, Isotopes, General Atomics (TRIGA) from high-income economy countries. The first phase will take effect immediately and the fee will increase from no higher than $3,750 per kg total mass (not heavy metal mass) to $5,625 per kg total mass for SNF containing low enriched uranium (LEU). The second phase will be implemented automatically on January 1, 2014, and the fees will increase from $5,625 per kg total mass to $7,500 per kg total mass for shipments of SNF containing LEU and from no higher than $4,500 per kg total mass to $6,750 per kg total mass for SNF containing highly enriched uranium (HEU). The third phase will be implemented automatically on January 1, 2016, and the fee will increase from $6,750 per kg total mass to $9,000 per kg total mass for shipments of SNF containing HEU. DOE is also implementing a new minimum fee of $200,000 per shipment of any type and amount of eligible SNF to reflect a minimum cost of providing acceptance services. This minimum fee will take effect immediately. In the case where a reactor operator already has a signed and executed contract with DOE, DOE intends to negotiate an equitable adjustment to the fee in accordance with this revised fee policy. Under this revised fee policy, the fee for return of TRIGA fuel will be the same as that of aluminum based fuel. All other aspects of the fee policy are unaffected by this Notice. This is the first fee increase since the fee policy was established in 1996, and will help DOE offset a portion of the increase in operation costs of managing SNF. DOE will continue to pay the costs for shipping, receipt and management of SNF from other than high-income economy countries. All other conditions and policies as previously established for acceptance of FRR SNF will continue to apply. DOE reserves the right to revise the fee policy at any time to respond to changed circumstances. DOE also reserves the right to adjust the fee set in an acceptance contract if there are unique and compelling circumstances that make it in DOE's best interest to do so.

  17. Implementation and control of a 3 degree-of-freedom, force-reflecting manual controller

    NASA Astrophysics Data System (ADS)

    Kim, Whee-Kuk; Bevill, Pat; Tesar, Delbert

    1991-02-01

    Most available manual controllers which are used in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size heavy weight high cost low magnitude of reflecting-force lack of smoothness insufficient transparency and simplified architectures. A compact smooth lightweight portable universal manual controller could provide a markedly improved level of transparency and be able to drive a broad spectrum of slave manipulators. This implies that a single stand-off position could be used for a diverse population of remote systems and that a standard environment for training of operators would result in reduced costs and higher reliability. In the implementation presented in this paper a parallel 3 degree-of-freedom (DOF) spherical structure (for compactness and reduced weight) is combined with high gear-ratio reducers using a force control algorithm to produce a " power steering" effect for enhanced smoothness and transparency. The force control algorithm has the further benefit of minimizing the effect of the system friction and non-linear inertia forces. The fundamental analytical description for the spherical force-reflecting manual controller such as forward position analysis reflecting-force transformation and applied force control algorithm are presented. Also a brief description of the system integration its actual implementation and preliminary test results are presented in the paper.

  18. 31 CFR 540.318 - Uranium Hexafluoride (UF6).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Uranium Hexafluoride (UF6). 540.318... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.318 Uranium Hexafluoride (UF6). The term uranium...

  19. 31 CFR 540.318 - Uranium Hexafluoride (UF6).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Uranium Hexafluoride (UF6). 540.318... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.318 Uranium Hexafluoride (UF6). The term uranium...

  20. 31 CFR 540.318 - Uranium Hexafluoride (UF6).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Uranium Hexafluoride (UF6). 540.318... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.318 Uranium Hexafluoride (UF6). The term uranium...

  1. 31 CFR 540.309 - Natural uranium.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Natural uranium. 540.309 Section 540... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.309 Natural uranium. The term natural uranium means uranium found in...

  2. 31 CFR 540.309 - Natural uranium.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Natural uranium. 540.309 Section 540... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.309 Natural uranium. The term natural uranium means uranium found in...

  3. 31 CFR 540.309 - Natural uranium.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Natural uranium. 540.309 Section 540... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.309 Natural uranium. The term natural uranium means uranium found in...

  4. 31 CFR 540.316 - Uranium enrichment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Uranium enrichment. 540.316 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.316 Uranium enrichment. The term uranium enrichment means the process of...

  5. 31 CFR 540.318 - Uranium Hexafluoride (UF6).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Uranium Hexafluoride (UF6). 540.318... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.318 Uranium Hexafluoride (UF6). The term uranium...

  6. 31 CFR 540.316 - Uranium enrichment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Uranium enrichment. 540.316 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.316 Uranium enrichment. The term uranium enrichment means the process of...

  7. 31 CFR 540.316 - Uranium enrichment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Uranium enrichment. 540.316 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.316 Uranium enrichment. The term uranium enrichment means the process of...

  8. 31 CFR 540.316 - Uranium enrichment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Uranium enrichment. 540.316 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.316 Uranium enrichment. The term uranium enrichment means the process of...

  9. 31 CFR 540.318 - Uranium Hexafluoride (UF6).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Uranium Hexafluoride (UF6). 540.318... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.318 Uranium Hexafluoride (UF6). The term uranium...

  10. NEUTRON MULTIPLICITY AND ACTIVE WELL NEUTRON COINCIDENCE VERIFICATION MEASUREMENTS PERFORMED FOR MARCH 2009 SEMI-ANNUAL DOE INVENTORY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewberry, R.; Ayers, J.; Tietze, F.

    The Analytical Development (AD) Section field nuclear measurement group performed six 'best available technique' verification measurements to satisfy a DOE requirement instituted for the March 2009 semi-annual inventory. The requirement of (1) yielded the need for SRNL Research Operations Department Material Control & Accountability (MC&A) group to measure the Pu content of five items and the highly enrich uranium (HEU) content of two. No 14Q-qualified measurement equipment was available to satisfy the requirement. The AD field nuclear group has routinely performed the required Confirmatory Measurements for the semi-annual inventories for fifteen years using sodium iodide and high purity germanium (HpGe)more » {gamma}-ray pulse height analysis nondestructive assay (NDA) instruments. With appropriate {gamma}-ray acquisition modeling, the HpGe spectrometers can be used to perform verification-type quantitative assay for Pu-isotopics and HEU content. The AD nuclear NDA group is widely experienced with this type of measurement and reports content for these species in requested process control, MC&A booking, and holdup measurements assays Site-wide. However none of the AD HpGe {gamma}-ray spectrometers have been 14Q-qualified, and the requirement of reference 1 specifically excluded a {gamma}-ray PHA measurement from those it would accept for the required verification measurements. The requirement of reference 1 was a new requirement for which the Savannah River National Laboratory (SRNL) Research Operations Department (ROD) MC&A group was unprepared. The criteria for exemption from verification were: (1) isotope content below 50 grams; (2) intrinsically tamper indicating or TID sealed items which contain a Category IV quantity of material; (3) assembled components; and (4) laboratory samples. Therefore all (SRNL) Material Balance Area (MBA) items with greater than 50 grams total Pu or greater than 50 grams HEU were subject to a verification measurement. The pass/fail criteria of reference 7 stated 'The facility will report measured values, book values, and statistical control limits for the selected items to DOE SR...', and 'The site/facility operator must develop, document, and maintain measurement methods for all nuclear material on inventory'. These new requirements exceeded SRNL's experience with prior semi-annual inventory expectations, but allowed the AD nuclear field measurement group to demonstrate its excellent adaptability and superior flexibility to respond to unpredicted expectations from the DOE customer. The requirements yielded five SRNL items subject to Pu verification and two SRNL items subject to HEU verification. These items are listed and described in Table 1.« less

  11. Acoustic Metadata Management and Transparent Access to Networked Oceanographic Data Sets

    DTIC Science & Technology

    2013-09-30

    connectivity (ODBC) compliant data source for which drivers are available (e.g. MySQL , Oracle database, Postgres) can now be imported. Implementation...the possibility of speeding data transmission through compression (implemented) or the potential to use alternative data formats such as Java script

  12. The Use of Performance Metrics for the Assessment of Safeguards Effectiveness at the State Level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bachner K. M.; George Anzelon, Lawrence Livermore National Laboratory, Livermore, CA Yana Feldman, Lawrence Livermore National Laboratory, Livermore, CA Mark Goodman,Department of State, Washington, DC Dunbar Lockwood, National Nuclear Security Administration, Washington, DC Jonathan B. Sanborn, JBS Consulting, LLC, Arlington, VA.

    In the ongoing evolution of International Atomic Energy Agency (IAEA) safeguards at the state level, many safeguards implementation principles have been emphasized: effectiveness, efficiency, non-discrimination, transparency, focus on sensitive materials, centrality of material accountancy for detecting diversion, independence, objectivity, and grounding in technical considerations, among others. These principles are subject to differing interpretations and prioritizations and sometimes conflict. This paper is an attempt to develop metrics and address some of the potential tradeoffs inherent in choices about how various safeguards policy principles are implemented. The paper carefully defines effective safeguards, including in the context of safeguards approaches that take accountmore » of the range of state-specific factors described by the IAEA Secretariat and taken note of by the Board in September 2014, and (2) makes use of performance metrics to help document, and to make transparent, how safeguards implementation would meet such effectiveness requirements.« less

  13. Roadmap for Early Childhood and K-12 Data Linkages: Key Focus Areas to Ensure Quality Implementation. Quality Implementation Roadmaps

    ERIC Educational Resources Information Center

    Data Quality Campaign, 2016

    2016-01-01

    Every state can create secure, robust linkages between early childhood and K-12 data systems, and effectively use the information from these linkages to implement initiatives to support programs and children, answer key policy questions, and be transparent about how the state's early childhood investments prepare students for success in school and…

  14. Is your article EV-TRACKed?

    PubMed

    Van Deun, Jan; Hendrix, An

    2017-01-01

    The EV-TRACK knowledgebase is developed to cope with the need for transparency and rigour to increase reproducibility and facilitate standardization of extracellular vesicle (EV) research. The knowledgebase includes a checklist for authors and editors intended to improve the transparency of methodological aspects of EV experiments, allows queries and meta-analysis of EV experiments and keeps track of the current state of the art. Widespread implementation by the EV research community is key to its success.

  15. Continuous, highly flexible, and transparent graphene films by chemical vapor deposition for organic photovoltaics.

    PubMed

    Gomez De Arco, Lewis; Zhang, Yi; Schlenker, Cody W; Ryu, Koungmin; Thompson, Mark E; Zhou, Chongwu

    2010-05-25

    We report the implementation of continuous, highly flexible, and transparent graphene films obtained by chemical vapor deposition (CVD) as transparent conductive electrodes (TCE) in organic photovoltaic cells. Graphene films were synthesized by CVD, transferred to transparent substrates, and evaluated in organic solar cell heterojunctions (TCE/poly-3,4-ethylenedioxythiophene:poly styrenesulfonate (PEDOT:PSS)/copper phthalocyanine/fullerene/bathocuproine/aluminum). Key to our success is the continuous nature of the CVD graphene films, which led to minimal surface roughness ( approximately 0.9 nm) and offered sheet resistance down to 230 Omega/sq (at 72% transparency), much lower than stacked graphene flakes at similar transparency. In addition, solar cells with CVD graphene and indium tin oxide (ITO) electrodes were fabricated side-by-side on flexible polyethylene terephthalate (PET) substrates and were confirmed to offer comparable performance, with power conversion efficiencies (eta) of 1.18 and 1.27%, respectively. Furthermore, CVD graphene solar cells demonstrated outstanding capability to operate under bending conditions up to 138 degrees , whereas the ITO-based devices displayed cracks and irreversible failure under bending of 60 degrees . Our work indicates the great potential of CVD graphene films for flexible photovoltaic applications.

  16. 31 CFR 540.317 - Uranium feed; natural uranium feed.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Uranium feed; natural uranium feed... (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.317 Uranium feed; natural uranium feed. The...

  17. 31 CFR 540.317 - Uranium feed; natural uranium feed.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Uranium feed; natural uranium feed... (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.317 Uranium feed; natural uranium feed. The...

  18. 31 CFR 540.308 - Low Enriched Uranium (LEU).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Low Enriched Uranium (LEU). 540.308... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.308 Low Enriched Uranium (LEU). The term low enriched...

  19. 31 CFR 540.308 - Low Enriched Uranium (LEU).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Low Enriched Uranium (LEU). 540.308... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.308 Low Enriched Uranium (LEU). The term low enriched...

  20. 31 CFR 540.308 - Low Enriched Uranium (LEU).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Low Enriched Uranium (LEU). 540.308... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.308 Low Enriched Uranium (LEU). The term low enriched...

  1. 31 CFR 540.317 - Uranium feed; natural uranium feed.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Uranium feed; natural uranium feed... (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.317 Uranium feed; natural uranium feed. The...

  2. 31 CFR 540.308 - Low Enriched Uranium (LEU).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Low Enriched Uranium (LEU). 540.308... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.308 Low Enriched Uranium (LEU). The term low enriched...

  3. 31 CFR 540.308 - Low Enriched Uranium (LEU).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Low Enriched Uranium (LEU). 540.308... OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.308 Low Enriched Uranium (LEU). The term low enriched...

  4. 76 FR 51358 - National Nuclear Security Administration Amended Record of Decision: Disposition of Surplus...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-18

    ...: Disposition of Surplus Highly Enriched Uranium Environmental Impact Statement AGENCY: National Nuclear... decision at that time. The Supplement Analysis analyzed the potential environmental impacts associated with... radioactive waste (LLW). The HEU EIS evaluated the potential environmental impacts of down- blending at up to...

  5. Fast Neutron Spectrum Potassium Worth for Space Power Reactor Design Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bess, John D.; Marshall, Margaret A.; Briggs, J. Blair

    2015-03-01

    A variety of critical experiments were constructed of enriched uranium metal (oralloy ) during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Ofmore » the hundreds of delayed critical experiments, one was performed that consisted of uranium metal annuli surrounding a potassium-filled, stainless steel can. The outer diameter of the annuli was approximately 13 inches (33.02 cm) with an inner diameter of 7 inches (17.78 cm). The diameter of the stainless steel can was 7 inches (17.78 cm). The critical height of the configurations was approximately 5.6 inches (14.224 cm). The uranium annulus consisted of multiple stacked rings, each with radial thicknesses of 1 inch (2.54 cm) and varying heights. A companion measurement was performed using empty stainless steel cans; the primary purpose of these experiments was to test the fast neutron cross sections of potassium as it was a candidate for coolant in some early space power reactor designs.The experimental measurements were performed on July 11, 1963, by J. T. Mihalczo and M. S. Wyatt (Ref. 1) with additional information in its corresponding logbook. Unreflected and unmoderated experiments with the same set of highly enriched uranium metal parts were performed at the Oak Ridge Critical Experiments Facility in the 1960s and are evaluated in the International Handbook for Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) with the identifier HEU MET FAST 051. Thin graphite reflected (2 inches or less) experiments also using the same set of highly enriched uranium metal parts are evaluated in HEU MET FAST 071. Polyethylene-reflected configurations are evaluated in HEU-MET-FAST-076. A stack of highly enriched metal discs with a thick beryllium top reflector is evaluated in HEU-MET-FAST-069, and two additional highly enriched uranium annuli with beryllium cores are evaluated in HEU-MET-FAST-059. Both detailed and simplified model specifications are provided in this evaluation. Both of these fast neutron spectra assemblies were determined to be acceptable benchmark experiments. The calculated eigenvalues for both the detailed and the simple benchmark models are within ~0.26 % of the benchmark values for Configuration 1 (calculations performed using MCNP6 with ENDF/B-VII.1 neutron cross section data), but under-calculate the benchmark values by ~7s because the uncertainty in the benchmark is very small: ~0.0004 (1s); for Configuration 2, the under-calculation is ~0.31 % and ~8s. Comparison of detailed and simple model calculations for the potassium worth measurement and potassium mass coefficient yield results approximately 70 – 80 % lower (~6s to 10s) than the benchmark values for the various nuclear data libraries utilized. Both the potassium worth and mass coefficient are also deemed to be acceptable benchmark experiment measurements.« less

  6. Evaluation of HFIR LEU Fuel Using the COMSOL Multiphysics Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Primm, Trent; Ruggles, Arthur; Freels, James D

    2009-03-01

    A finite element computational approach to simulation of the High Flux Isotope Reactor (HFIR) Core Thermal-Fluid behavior is developed. These models were developed to facilitate design of a low enriched core for the HFIR, which will have different axial and radial flux profiles from the current HEU core and thus will require fuel and poison load optimization. This report outlines a stepwise implementation of this modeling approach using the commercial finite element code, COMSOL, with initial assessment of fuel, poison and clad conduction modeling capability, followed by assessment of mating of the fuel conduction models to a one dimensional fluidmore » model typical of legacy simulation techniques for the HFIR core. The model is then extended to fully couple 2-dimensional conduction in the fuel to a 2-dimensional thermo-fluid model of the coolant for a HFIR core cooling sub-channel with additional assessment of simulation outcomes. Finally, 3-dimensional simulations of a fuel plate and cooling channel are presented.« less

  7. The power of data--from data mining to consumer pricing and quality-of-care tools.

    PubMed

    Malof, Leah C

    2013-01-01

    Transparency tools, whether offered by carriers or third-party administrators, rely on adequate experience, by market and by service, to provide information to consumers about health care costs and quality of care. The opportunities for savings to individual consumers and to employer-sponsored health plans are clearly significant and possible if people will use the tools and act. This article reviews two studies showing a shift in consumer claims experience to less costly services afte the implementation of a transparency tool and when combined with a consumer-driven health plan. It also outlines best practices employers can implement to carefully craft interventions to engage and create value in the minds of health care consumers.

  8. A Uniform Framework of Global Nuclear Materials Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dupree, S.A.; Mangan, D.L.; Sanders, T.L

    1999-04-20

    Global Nuclear Materials Management (GNMM) anticipates and supports a growing international recognition of the importance of uniform, effective management of civilian, excess defense, and nuclear weapons materials. We expect thereto be a continuing increase in both the number of international agreements and conventions on safety, security, and transparency of nuclear materials, and the number of U.S.-Russian agreements for the safety, protection, and transparency of weapons and excess defense materials. This inventory of agreements and conventions may soon expand into broad, mandatory, international programs that will include provisions for inspection, verification, and transparency, To meet such demand the community must buildmore » on the resources we have, including State agencies, the IAEA and regional organizations. By these measures we will meet the future expectations for monitoring and inspection of materials, maintenance of safety and security, and implementation of transparency measures.« less

  9. Ionic Liquid Activation of Amorphous Metal-Oxide Semiconductors for Flexible Transparent Electronic Devices

    DOE PAGES

    Pudasaini, Pushpa Raj; Noh, Joo Hyon; Wong, Anthony T.; ...

    2016-02-09

    To begin this abstract, amorphous metal-oxide semiconductors offer the high carrier mobilities and excellent large-area uniformity required for high performance, transparent, flexible electronic devices; however, a critical bottleneck to their widespread implementation is the need to activate these materials at high temperatures which are not compatible with flexible polymer substrates. The highly controllable activation of amorphous indium gallium zinc oxide semiconductor channels using ionic liquid gating at room temperature is reported. Activation is controlled by electric field-induced oxygen migration across the ionic liquid-semiconductor interface. In addition to activation of unannealed devices, it is shown that threshold voltages of a transistormore » can be linearly tuned between the enhancement and depletion modes. Finally, the first ever example of transparent flexible thin film metal oxide transistor on a polyamide substrate created using this simple technique is demonstrated. Finally, this study demonstrates the potential of field-induced activation as a promising alternative to traditional postdeposition thermal annealing which opens the door to wide scale implementation into flexible electronic applications.« less

  10. Intelligent Agent Transparency in Human-Agent Teaming for Multi-UxV Management.

    PubMed

    Mercado, Joseph E; Rupp, Michael A; Chen, Jessie Y C; Barnes, Michael J; Barber, Daniel; Procci, Katelyn

    2016-05-01

    We investigated the effects of level of agent transparency on operator performance, trust, and workload in a context of human-agent teaming for multirobot management. Participants played the role of a heterogeneous unmanned vehicle (UxV) operator and were instructed to complete various missions by giving orders to UxVs through a computer interface. An intelligent agent (IA) assisted the participant by recommending two plans-a top recommendation and a secondary recommendation-for every mission. A within-subjects design with three levels of agent transparency was employed in the present experiment. There were eight missions in each of three experimental blocks, grouped by level of transparency. During each experimental block, the IA was incorrect three out of eight times due to external information (e.g., commander's intent and intelligence). Operator performance, trust, workload, and usability data were collected. Results indicate that operator performance, trust, and perceived usability increased as a function of transparency level. Subjective and objective workload data indicate that participants' workload did not increase as a function of transparency. Furthermore, response time did not increase as a function of transparency. Unlike previous research, which showed that increased transparency resulted in increased performance and trust calibration at the cost of greater workload and longer response time, our results support the benefits of transparency for performance effectiveness without additional costs. The current results will facilitate the implementation of IAs in military settings and will provide useful data to the design of heterogeneous UxV teams. © 2016, Human Factors and Ergonomics Society.

  11. Is your article EV-TRACKed?

    PubMed Central

    Van Deun, Jan; Hendrix, An

    2017-01-01

    ABSTRACT The EV-TRACK knowledgebase is developed to cope with the need for transparency and rigour to increase reproducibility and facilitate standardization of extracellular vesicle (EV) research. The knowledgebase includes a checklist for authors and editors intended to improve the transparency of methodological aspects of EV experiments, allows queries and meta-analysis of EV experiments and keeps track of the current state of the art. Widespread implementation by the EV research community is key to its success. PMID:29184624

  12. Optimization of GaN Nanorod Growth Conditions for Coalescence Overgrowth

    DTIC Science & Technology

    2016-02-04

    GaN core and QW deposition, an NR LED array can be implemented by covering the NRs with a transparent conductor . It has been demonstrated that the...with a transparent conductor . It has been demonstrated that the optical and electrical performances of an NR LED array can be comparable to those of a...a process of buffered oxide etching for removing this SiNx layer on the sidewalls is required before sidewall QW deposition. Nevertheless, the

  13. Design, implementation and reporting strategies to reduce the instance and impact of missing patient-reported outcome (PRO) data: a systematic review.

    PubMed

    Mercieca-Bebber, Rebecca; Palmer, Michael J; Brundage, Michael; Calvert, Melanie; Stockler, Martin R; King, Madeleine T

    2016-06-15

    Patient-reported outcomes (PROs) provide important information about the impact of treatment from the patients' perspective. However, missing PRO data may compromise the interpretability and value of the findings. We aimed to report: (1) a non-technical summary of problems caused by missing PRO data; and (2) a systematic review by collating strategies to: (A) minimise rates of missing PRO data, and (B) facilitate transparent interpretation and reporting of missing PRO data in clinical research. Our systematic review does not address statistical handling of missing PRO data. MEDLINE and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases (inception to 31 March 2015), and citing articles and reference lists from relevant sources. English articles providing recommendations for reducing missing PRO data rates, or strategies to facilitate transparent interpretation and reporting of missing PRO data were included. 2 reviewers independently screened articles against eligibility criteria. Discrepancies were resolved with the research team. Recommendations were extracted and coded according to framework synthesis. 117 sources (55% discussion papers, 26% original research) met the eligibility criteria. Design and methodological strategies for reducing rates of missing PRO data included: incorporating PRO-specific information into the protocol; carefully designing PRO assessment schedules and defining termination rules; minimising patient burden; appointing a PRO coordinator; PRO-specific training for staff; ensuring PRO studies are adequately resourced; and continuous quality assurance. Strategies for transparent interpretation and reporting of missing PRO data include utilising auxiliary data to inform analysis; transparently reporting baseline PRO scores, rates and reasons for missing data; and methods for handling missing PRO data. The instance of missing PRO data and its potential to bias clinical research can be minimised by implementing thoughtful design, rigorous methodology and transparent reporting strategies. All members of the research team have a responsibility in implementing such strategies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. 31 CFR 540.315 - Uranium-235 (U235).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Uranium-235 (U235). 540.315 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.315 Uranium-235 (U235). The term uranium-235 or U235 means the fissile...

  15. 31 CFR 540.315 - Uranium-235 (U235).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Uranium-235 (U235). 540.315 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.315 Uranium-235 (U235). The term uranium-235 or U235 means the fissile...

  16. 31 CFR 540.315 - Uranium-235 (U235).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Uranium-235 (U235). 540.315 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.315 Uranium-235 (U235). The term uranium-235 or U235 means the fissile...

  17. 31 CFR 540.315 - Uranium-235 (U235).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Uranium-235 (U235). 540.315 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.315 Uranium-235 (U235). The term uranium-235 or U235 means the fissile...

  18. 31 CFR 540.315 - Uranium-235 (U235).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Uranium-235 (U235). 540.315 Section... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY HIGHLY ENRICHED URANIUM (HEU) AGREEMENT ASSETS CONTROL REGULATIONS General Definitions § 540.315 Uranium-235 (U235). The term uranium-235 or U235 means the fissile...

  19. Development of New Transportation/Storage Cask System for Use by DOE Russian Research Reactor Fuel Return Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael Tyacke; Frantisek Svitak; Jiri Rychecky

    2010-04-01

    The United States, the Russian Federation, and the International Atomic Energy Agency (IAEA) have been working together on a program called the Russian Research Reactor Fuel Return (RRRFR) Program. The purpose of this program is to return Soviet or Russian supplied high-enriched uranium (HEU) fuel currently stored at Russian-designed research reactors throughout the world to Russia. To accommodate transport of the HEU spent nuclear fuel (SNF), a new large-capacity transport/storage cask system was specially designed for handling and operations under the unique conditions for these research reactor facilities. This new cask system is named the ŠKODA VPVR/M cask. The design,more » licensing, testing, and delivery of this new cask system are the results of a significant international cooperative effort by several countries and involved numerous private and governmental organizations. This paper contains the following sections: (1) Introduction/Background; (2) VPVR/M Cask Description; (3) Ancillary Equipment, (4) Cask Licensing; (5) Cask Demonstration and Operations; (6) IAEA Procurement, Quality Assurance Inspections, Fabrication, and Delivery; and, (7) Summary and Conclusions.« less

  20. Development of a New Transportation/Storage Cask System for Use by the DOE Russian Research Reactor Fuel Return Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael J. Tyacke; Frantisek Svitak; Jiri Rychecky

    2007-10-01

    The United States, the Russian Federation, and the International Atomic Energy Agency (IAEA) have been working together on a program called the Russian Research Reactor Fuel Return (RRRFR) Program. The purpose of this program is to return Soviet or Russian-supplied high-enriched uranium (HEU) fuel, currently stored at Russian-designed research reactors throughout the world, to Russia. To accommodate transport of the HEU spent nuclear fuel (SNF), a new large-capacity transport/storage cask system was specially designed for handling and operations under the unique conditions at these research reactor facilities. This new cask system is named the ŠKODA VPVR/M cask. The design, licensing,more » testing, and delivery of this new cask system result from a significant international cooperative effort by several countries and involved numerous private and governmental organizations. This paper contains the following sections: 1) Introduction; 2) VPVR/M Cask Description; 3) Ancillary Equipment, 4) Cask Licensing; 5) Cask Demonstration and Operations; 6) IAEA Procurement, Quality Assurance Inspections, Fabrication, and Delivery; and, 7) Conclusions.« less

  1. Neutronics Analyses of the Minimum Original HEU TREAT Core

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kontogeorgakos, D.; Connaway, H.; Yesilyurt, G.

    2014-04-01

    This work was performed to support the feasibility study on the potential conversion of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory from the use of high-enriched uranium (HEU) fuel to the use of low-enriched uranium (LEU) fuel. The analyses were performed by the GTRI Reactor Conversion staff at the Argonne National Laboratory (ANL). The objective of this study was to validate the MCNP model of the TREAT reactor with the well-documented measurements which were taken during the start-up and early operation of TREAT. Furthermore, the effect of carbon graphitization was also addressed. The graphitization level was assumedmore » to be 100% (ANL/GTRI/TM-13/4). For this purpose, a set of experiments was chosen to validate the TREAT MCNP model, involving the approach to criticality procedure, in-core neutron flux measurements with foils, and isothermal temperature coefficient and temperature distribution measurements. The results of this study extended the knowledge base for the TREAT MCNP calculations and established the credibility of the MCNP model to be used in the core conversion feasibility analysis.« less

  2. Controlling Pu behavior on Titania: Implications for LEU Fission-Based Mo-99 Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youker, Amanda J.; Brown, M. Alex; Heltemes, Thad A.

    Molybdenum-99 is the parent isotope of the most widely used isotope, technetium-99m, in all diagnostic nuclear medicine procedures. Due to proliferation concerns associated with the use of highly enriched uranium (HEU), the preferred method of fission-based Mo-99 production uses low enriched uranium (LEU) targets. Using LEU versus HEU for Mo-99 production produces similar to 30 times more Pu-239, due to neutron capture on U-238 to produce Np-239, which ultimately decays to Pu-239 (t(1/2) = 24,110 yr). Argonne National Laboratory is supporting a potential US Mo-99 producer in their efforts to produce Mo-99 from an LEU solution. In order to mitigatemore » the generation of large volumes of greater-than-class-C (GTCC) low level waste (Pu-239 concentrations greater than 1 nCi/g), we have focused our efforts on the separation chemistry of Pu and Mo with a titania sorbent in sulfate media. Results from batch and column experiments show that temperature and acid wash concentration can be used to control Pu behavior on titania.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swift, Alicia L.

    There is no better time than now to close the loophole in Article IV of the Nuclear Non-proliferation Treaty (NPT) that excludes military uses of fissile material from nuclear safeguards. Several countries have declared their intention to pursue and develop naval reactor technology, including Argentina, Brazil, Iran, and Pakistan, while other countries such as China, India, Russia, and the United States are expanding their capabilities. With only a minority of countries using low enriched uranium (LEU) fuel in their naval reactors, it is possible that a state could produce highly enriched uranium (HEU) under the guise of a nuclear navymore » while actually stockpiling the material for a nuclear weapon program. This paper examines the likelihood that non-nuclear weapon states exploit the loophole to break out from the NPT and also the regional ramifications of deterrence and regional stability of expanding naval forces. Possible solutions to close the loophole are discussed, including expanding the scope of the Fissile Material Cut-off Treaty, employing LEU fuel instead of HEU fuel in naval reactors, amending the NPT, creating an export control regime for naval nuclear reactors, and forming individual naval reactor safeguards agreements.« less

  4. Neutronics Conversion Analyses of the Laue-Langevin Institute (ILL) High Flux Reactor (RHF)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergeron, A.; Dionne, B.; Calzavara, Y.

    2014-09-30

    The following report describes the neutronics results obtained with the MCNP model of the RHF U7Mo LEU reference design that has been established in 2010 during the feasibility analysis. This work constitutes a complete and detailed neutronics analysis of that LEU design using models that have been significantly improved since 2010 and the release of the feasibility report. When possible, the credibility of the neutronics model is tested by comparing the HEU model results with experimental data or other codes calculations results. The results obtained with the LEU model are systematically compared to the HEU model. The changes applied tomore » the neutronics model lead to better comparisons with experimental data or improved the calculation efficiency but do not challenge the conclusion of the feasibility analysis. If the U7Mo fuel is commercially available, not cost prohibitive, a back-end solution is established and if it is possible to manufacture the proposed element, neutronics analyses show that the performance of the reactor would not be challenged by the conversion to LEU fuel.« less

  5. Illumination and radiative cooling

    DOEpatents

    Fan, Shanhui; Raman, Aaswath Pattabhi; Zhu, Linxiao; Rephaeli, Eden

    2018-03-20

    Aspects of the present disclosure are directed to providing and/or controlling electromagnetic radiation. As may be implemented in accordance with one or more embodiments, an apparatus includes a first structure that contains an object, and a second structure that is transparent at solar wavelengths and emissive in the atmospheric electromagnetic radiation transparency window. The second structure operates with the first structure to pass light into the first structure for illuminating the object, and to radiatively cool the object while preserving the object's color.

  6. Neurologic Outcomes in HIV-Exposed/Uninfected Infants Exposed to Antiretroviral Drugs During Pregnancy in Latin America and the Caribbean

    PubMed Central

    Spaulding, Alicen B.; Yu, Qilu; Civitello, Lucy; Mussi-Pinhata, Marisa M.; Pinto, Jorge; Gomes, Ivete M.; Alarcón, Jorge O.; Siberry, George K.; Harris, D. Robert

    2016-01-01

    Abstract To evaluate antiretroviral (ARV) drug exposure and other factors during pregnancy that may increase the risk of neurologic conditions (NCs) in HIV-exposed/uninfected (HEU) infants. A prospective cohort study was conducted at 24 clinical sites in Latin America and the Caribbean. Data on maternal demographics, health, HIV disease status, and ARV use during pregnancy were collected. Infant data included measurement of head circumference after birth and reported medical diagnoses at birth, 6–12 weeks, and 6 months. Only infants with maternal exposure to combination ARV therapy (cART) (≥3 drugs from ≥2 drug classes) during pregnancy were included. Microcephaly, defined as head circumference for age z-score less than −2, and NC were evaluated for their association with covariates, including individual ARVs, using bivariable and logistic regression analyses. From 2002 to 2009, 1,400 HEU infants met study inclusion criteria. At least one NC was reported in 134 (9.6%; 95% confidence interval [CI]: 8.1–11.2), microcephaly in 105 (7.5%; 95% CI: 6.2–9.0), and specific neurologic diagnoses in 33 (2.4%; 95% CI: 1.6–3.3) HEU infants. Microcephaly and NC were not significantly associated with any specific ARV analyzed (p > 0.05). Covariates associated with increased odds of NC included male sex (odds ratio [OR] = 1.9; 95% CI: 1.3–2.8), birth weight <2.5 kg (OR = 3.1; 95% CI: 2.1–4.8), 1-min Apgar score <7 (OR = 2.5; 95% CI: 1.4–4.4), and infant infections (OR = 2.5; 95% CI: 1.5–4.1). No ARV investigated was associated with adverse neurologic outcomes. Continued investigation of such associations may be warranted as new ARVs are used during pregnancy and cART exposure during the first trimester becomes increasingly common. PMID:26879281

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stillman, J. A.; Feldman, E. E.; Wilson, E. H.

    This report contains the results of reactor accident analyses for the University of Missouri Research Reactor (MURR). The calculations were performed as part of the conversion from the use of highly-enriched uranium (HEU) fuel to the use of low-enriched uranium (LEU) fuel. The analyses were performed by staff members of the Global Threat Reduction Initiative (GTRI) Reactor Conversion Program at the Argonne National Laboratory (ANL), the MURR Facility, and the Nuclear Engineering Program – College of Engineering, University of Missouri-Columbia. The core conversion to LEU is being performed with financial support from the U. S. government. This report contains themore » results of reactor accident analyses for the University of Missouri Research Reactor (MURR). The calculations were performed as part of the conversion from the use of highly-enriched uranium (HEU) fuel to the use of low-enriched uranium (LEU) fuel. The analyses were performed by staff members of the Global Threat Reduction Initiative (GTRI) Reactor Conversion Program at the Argonne National Laboratory (ANL), the MURR Facility, and the Nuclear Engineering Program – College of Engineering, University of Missouri-Columbia. The core conversion to LEU is being performed with financial support from the U. S. government. In the framework of non-proliferation policies, the international community presently aims to minimize the amount of nuclear material available that could be used for nuclear weapons. In this geopolitical context most research and test reactors, both domestic and international, have started a program of conversion to the use of LEU fuel. A new type of LEU fuel based on an alloy of uranium and molybdenum (U-Mo) is expected to allow the conversion of U.S. domestic high performance reactors like MURR. This report presents the results of a study of core behavior under a set of accident conditions for MURR cores fueled with HEU U-Alx dispersion fuel or LEU monolithic U-Mo alloy fuel with 10 wt% Mo (U-10Mo).« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, Margaret A.

    In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared withmore » the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files” (Reference 1). While performing the ORSphere experiments care was taken to accurately document component dimensions (±0.0001 inches), masses (±0.01 g), and material data. The experiment was also set up to minimize the amount of structural material in the sphere proximity. Two, correlated spheres were evaluated and judged to be acceptable as criticality benchmark experiments. This evaluation is given in HEU-MET-FAST-100. The second, smaller sphere was used for additional reactor physics measurements. Worth measurements (Reference 1, 2, 3 and 4), the delayed neutron fraction (Reference 3, 4 and 5) and surface material worth coefficient (Reference 1 and 2) are all measured and judged to be acceptable as benchmark data. The prompt neutron decay (Reference 6), relative fission density (Reference 7) and relative neutron importance (Reference 7) were measured, but are not evaluated. Information for the evaluation was compiled from References 1 through 7, the experimental logbooks 8 and 9 ; additional drawings and notes provided by the experimenter; and communication with the lead experimenter, John T. Mihalczo.« less

  9. Space-Derived Transparency: Players, Policies, Implications, and Synergies

    NASA Astrophysics Data System (ADS)

    Kinnan, C. J.

    2001-06-01

    Space-derived transparency will become a common means of monitoring, preventing, and mitigating crises, verifying compliance with treaties and law, and enabling confidence and security building measures. Democratization and globalization, the proliferation of information technologies, the availability of commercial space high-resolution imagery, and the growing influence of NGOs invite this question: What is (space-derived) transparency and what effect does it have on US security policy? Three camps have emerged in the debate -Horaeists who seek to build a transnational society through complete transparency; Preservationists, mostly military, who fear the threat to national security, want to deny most space-derived information to non-traditional/non-state actors; and Synergists who seek to capitalize on the best of both camps. There is evidence suggesting that space-derived transparency is an inevitable trend and will resist even the best means of preservationist control. Space-derived transparency may change the dynamic of the security environment by introducing new players into the policy fomentation and implementation process. These players, if not properly schooled in imagery analysis or the potential effects of their use of misinterpreted space-derived imagery, could force policy makers to make fast, ill-considered decisions in order to respond to incidents. In some cases this fast response will defuse potential crises and in other situations these rushed decisions might result in policies without considering the potential consequences, which could turn incidents into crises. Space-derived transparency is a step forward into the future for each camp . . . the challenge for the United States lies in forging synergies in an increasingly transparent world while maintaining the balance between openness and security.

  10. A Resource Management Tool for Implementing Strategic Direction in an Academic Department

    ERIC Educational Resources Information Center

    Ringwood, John V.; Devitt, Frank; Doherty, Sean; Farrell, Ronan; Lawlor, Bob; McLoone, Sean C.; McLoone, Seamus F.; Rogers, Alan; Villing, Rudi; Ward, Tomas

    2005-01-01

    This paper reports on a load balancing system for an academic department, which can be used as an implementation mechanism for strategic planning. In essence, it consists of weighting each activity within the department and performing workload allocation based on this transparent scheme. The experience to date has been very positive, in terms of…

  11. 76 FR 23221 - Joint Public Roundtable on Issues Related to the Schedule for Implementing Final Rules for Swaps...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-26

    ... submissions will be reviewed jointly by the Agencies. All comments must be in English or be accompanied by an English translation. All submissions provided to either Agency in any electronic form or on paper will be... of CFTC Commissioner Scott D. O'Malia; Implementation Roundtable Seriatim; Certainty & Transparency I...

  12. Implementing a trustworthy cost-accounting model.

    PubMed

    Spence, Jay; Seargeant, Dan

    2015-03-01

    Hospitals and health systems can develop an effective cost-accounting model and maximize the effectiveness of their cost-accounting teams by focusing on six key areas: Implementing an enhanced data model. Reconciling data efficiently. Accommodating multiple cost-modeling techniques. Improving transparency of cost allocations. Securing department manager participation. Providing essential education and training to staff members and stakeholders.

  13. Experimental study of the rigidity and transparency to ionizing radiation of composite materials used in the enclosure under pressure of the Micromegas detector

    NASA Astrophysics Data System (ADS)

    Harbaoui, Imen; Besbes, Hatem; Chafra, Moez

    Innovation in the field of nuclear imaging is necessarily followed by a radical change in the detection principle. The gas detector Micromegas (Mesh Micro Structure Gaseous) could be an interesting option, thanks to the stability and robustness of such a detector. Thus, it was necessary to study the implementation of the detector enclosure in composite materials. The focus of the present study was the robustness and gamma rays transparency of a set of composites. The studied composites were reinforced with vegetable fibers (alfa), and synthetic fibers. The mechanical properties of all composites specimen were evaluated by three-point bending test, whereas, gamma ray transparency was evaluated by the exposition of composites specimen to a mono-energetic gamma ray beam emitted by a Technetium 99-m source. Findings revealed that the biocomposite materials using alfa fiber and Polymethyl Methacrylate matrix are very promising as long as they present good robustness and high gamma ray transparency in diagnostic range.

  14. High-performance single-crystalline arsenic-doped indium oxide nanowires for transparent thin-film transistors and active matrix organic light-emitting diode displays.

    PubMed

    Chen, Po-Chiang; Shen, Guozhen; Chen, Haitian; Ha, Young-geun; Wu, Chao; Sukcharoenchoke, Saowalak; Fu, Yue; Liu, Jun; Facchetti, Antonio; Marks, Tobin J; Thompson, Mark E; Zhou, Chongwu

    2009-11-24

    We report high-performance arsenic (As)-doped indium oxide (In(2)O(3)) nanowires for transparent electronics, including their implementation in transparent thin-film transistors (TTFTs) and transparent active-matrix organic light-emitting diode (AMOLED) displays. The As-doped In(2)O(3) nanowires were synthesized using a laser ablation process and then fabricated into TTFTs with indium-tin oxide (ITO) as the source, drain, and gate electrodes. The nanowire TTFTs on glass substrates exhibit very high device mobilities (approximately 1490 cm(2) V(-1) s(-1)), current on/off ratios (5.7 x 10(6)), steep subthreshold slopes (88 mV/dec), and a saturation current of 60 microA for a single nanowire. By using a self-assembled nanodielectric (SAND) as the gate dielectric, the device mobilities and saturation current can be further improved up to 2560 cm(2) V(-1) s(-1) and 160 microA, respectively. All devices exhibit good optical transparency (approximately 81% on average) in the visible spectral range. In addition, the nanowire TTFTs were utilized to control green OLEDs with varied intensities. Furthermore, a fully integrated seven-segment AMOLED display was fabricated with a good transparency of 40% and with each pixel controlled by two nanowire transistors. This work demonstrates that the performance enhancement possible by combining nanowire doping and self-assembled nanodielectrics enables silicon-free electronic circuitry for low power consumption, optically transparent, high-frequency devices assembled near room temperature.

  15. 10 CFR 50.64 - Limitations on the use of highly enriched uranium (HEU) in domestic non-power reactors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... domestic non-power reactors. 50.64 Section 50.64 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF... Director of the Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC... Director of the Office of Nuclear Reactor Regulation a written proposal for meeting the requirements of...

  16. 10 CFR 50.64 - Limitations on the use of highly enriched uranium (HEU) in domestic non-power reactors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... domestic non-power reactors. 50.64 Section 50.64 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF... Director of the Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC... Director of the Office of Nuclear Reactor Regulation a written proposal for meeting the requirements of...

  17. 10 CFR 50.64 - Limitations on the use of highly enriched uranium (HEU) in domestic non-power reactors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... domestic non-power reactors. 50.64 Section 50.64 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF... Director of the Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC... Director of the Office of Nuclear Reactor Regulation a written proposal for meeting the requirements of...

  18. Promoting transparency, accountability, and access through a multi-stakeholder initiative: lessons from the medicines transparency alliance.

    PubMed

    Vian, Taryn; Kohler, Jillian C; Forte, Gilles; Dimancesco, Deirdre

    2017-01-01

    Barriers to expanding access to medicines include weak pharmaceutical sector governance, lack of transparency and accountability, inadequate attention to social services on the political agenda, and financing challenges. Multi-stakeholder initiatives such as the Medicines Transparency Alliance (MeTA) may help overcome these barriers. Between 2008 and 2015, MeTA engaged stakeholders in the pharmaceutical sectors of seven countries (Ghana, Jordan, Kyrgyzstan, Peru, Philippines, Uganda, and Zambia) to promote access goals through greater transparency. We reviewed archival data to document MeTA activities and results related to transparency and accountability in the seven countries where it was implemented. We identified common themes and content areas, noting specific activities used to make information transparent and accessible, how data were used to inform discussions, and the purpose and timing of meetings and advocacy activities to help set priorities and influence governance decisions. The cross-case analysis looked for pathways which might link the MeTA strategies to results such as better policies or program improvements. Countries used evidence gathering, open meetings, and proactive information dissemination to increase transparency. MeTA fostered policy dialogue to bring together the many government, civil society and private company stakeholders concerned with access issues, and provided them with information to understand barriers to access at policy, organizational, and community levels. We found strong evidence that transparency was enhanced. Some evidence suggests that MeTA efforts contributed to new policies and civil society capacity strengthening although the impact on government accountability is not clear. MeTA appears to have achieved its goal of creating a multi-stakeholder shared policy space in which government, civil society, and private sector players can come together and have a voice in the national pharmaceutical policy making process. Assuming that transparency is in place to leverage accountability, the success of MeTA's efforts to promote accountability by the government as well as other stakeholders in the pharmaceutical sector will depend on how well efforts are sustained over time.

  19. Image quality affected by diffraction of aperture structure arrangement in transparent active-matrix organic light-emitting diode displays.

    PubMed

    Tsai, Yu-Hsiang; Huang, Mao-Hsiu; Jeng, Wei-de; Huang, Ting-Wei; Lo, Kuo-Lung; Ou-Yang, Mang

    2015-10-01

    Transparent display is one of the main technologies in next-generation displays, especially for augmented reality applications. An aperture structure is attached on each display pixel to partition them into transparent and black regions. However, diffraction blurs caused by the aperture structure typically degrade the transparent image when the light from a background object passes through finite aperture window. In this paper, the diffraction effect of an active-matrix organic light-emitting diode display (AMOLED) is studied. Several aperture structures have been proposed and implemented. Based on theoretical analysis and simulation, the appropriate aperture structure will effectively reduce the blur. The analysis data are also consistent with the experimental results. Compared with the various transparent aperture structure on AMOLED, diffraction width (zero energy position of diffraction pattern) of the optimize aperture structure can be reduced 63% and 31% in the x and y directions in CASE 3. Associated with a lenticular lens on the aperture structure, the improvement could reach to 77% and 54% of diffraction width in the x and y directions. Modulation transfer function and practical images are provided to evaluate the improvement of image blurs.

  20. Interim Open Source Software (OSS) Policy

    EPA Pesticide Factsheets

    This interim Policy establishes a framework to implement the requirements of the Office of Management and Budget's (OMB) Federal Source Code Policy to achieve efficiency, transparency and innovation through reusable and open source software.

  1. Programmable on-chip and off-chip network architecture on demand for flexible optical intra-datacenters.

    PubMed

    Rofoee, Bijan Rahimzadeh; Zervas, Georgios; Yan, Yan; Amaya, Norberto; Qin, Yixuan; Simeonidou, Dimitra

    2013-03-11

    The paper presents a novel network architecture on demand approach using on-chip and-off chip implementations, enabling programmable, highly efficient and transparent networking, well suited for intra-datacenter communications. The implemented FPGA-based adaptable line-card with on-chip design along with an architecture on demand (AoD) based off-chip flexible switching node, deliver single chip dual L2-Packet/L1-time shared optical network (TSON) server Network Interface Cards (NIC) interconnected through transparent AoD based switch. It enables hitless adaptation between Ethernet over wavelength switched network (EoWSON), and TSON based sub-wavelength switching, providing flexible bitrates, while meeting strict bandwidth, QoS requirements. The on and off-chip performance results show high throughput (9.86Ethernet, 8.68Gbps TSON), high QoS, as well as hitless switch-over.

  2. Transparent TiO 2 nanotube array photoelectrodes prepared via two-step anodization

    DOE PAGES

    Kim, Jin Young; Zhu, Kai; Neale, Nathan R.; ...

    2014-04-04

    Two-step anodization of transparent TiO 2 nanotube arrays has been demonstrated with aid of a Nb-doped TiO 2 buffer layer deposited between the Ti layer and TCO substrate. Enhanced physical adhesion and electrochemical stability provided by the buffer layer has been found to be important for successful implementation of the two-step anodization process. As a result, with the proposed approach, the morphology and thickness of NT arrays could be controlled very precisely, which in turn, influenced their optical and photoelectrochemical properties.

  3. Defense Technology Plan

    DTIC Science & Technology

    1994-09-01

    implementation of the services necessary to support transparent "information pull " operation of decision support systems. This infrastructure will be implemented...technology. Some aspects of this area such as user- pull , mobile and highly distributed operation, bandwidth needs and degree of securihy are Dol)-driven...by a variety of statutory requirements. R&D will provide enhanced mission effectiveness and maintenance of fragile ecosystems. The goalis to develop

  4. Implementation of a Tool to Enhance Evidence-Informed Decision Making in Public Health: Identifying Barriers and Facilitating Factors

    ERIC Educational Resources Information Center

    van der Heide, Iris; van der Noordt, Maaike; Proper, Karin I.; Schoemaker, Casper; van den Berg, Matthijs; Hamberg-van Reenen, Heleen H.

    2016-01-01

    One of the barriers regarding evidence-informed decision making is the gap between the needs of policy makers and the ways researchers present evidence. This pilot study evaluates the barriers and facilitators to the implementation of a tool to enhance transparent and unambiguous communication on scientific evidence by knowledge workers.…

  5. Non-compliance with the International Code of Marketing of Breast Milk Substitutes is not confined to the infant formula industry.

    PubMed

    Forsyth, Stewart

    2013-06-01

    Infant feeding policy and practice continues to be a contentious area of global health care. The infant formula industry is widely considered to be the bête noire with frequent claims that they adopt marketing and sales practices that are not compliant with the WHO Code. However, failure to resolve these issues over three decades suggests that there may be wider systemic failings. Review of published papers, commentaries and reports relating to the implementation and governance of the WHO Code with specific reference to issues of non-compliance. The analysis set out in this paper indicates that there are systemic failings at all levels of the implementation and monitoring process including the failure of WHO to successfully 'urge' governments to implement the Code in its entirety; a lack of political will by Member States to implement and monitor the Code and a lack of formal and transparent governance structures. Non-compliance with the WHO Code is not confined to the infant formula industry and several actions are identified, including the need to address issues of partnership working and the establishment of governance systems that are robust, independent and transparent.

  6. 77 FR 52105 - Announcement of the Innovation in Arms Control Challenge Under the America Competes...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ...,'' with the goal of spurring innovation, and developing scientific and technological options that will... transparency efforts. Processes, incentives, and technologies must, in theory, be practical and implementable...

  7. Loss-of-Flow and Loss-of-Pressure Simulations of the BR2 Research Reactor with HEU and LEU Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Licht, J.; Bergeron, A.; Dionne, B.

    2016-01-01

    Belgian Reactor 2 (BR2) is a research and test reactor located in Mol, Belgium and is primarily used for radioisotope production and materials testing. The Materials Management and Minimization (M3) Reactor Conversion Program of the National Nuclear Security Administration (NNSA) is supporting the conversion of the BR2 reactor from Highly Enriched Uranium (HEU) fuel to Low Enriched Uranium (LEU) fuel. The reactor core of BR2 is located inside a pressure vessel that contains 79 channels in a hyperboloid configuration. The core configuration is highly variable as each channel can contain a fuel assembly, a control or regulating rod, an experimentalmore » device, or a beryllium or aluminum plug. Because of this variability, a representative core configuration, based on current reactor use, has been defined for the fuel conversion analyses. The code RELAP5/Mod 3.3 was used to perform the transient thermal-hydraulic safety analyses of the BR2 reactor to support reactor conversion. The input model has been modernized relative to that historically used at BR2 taking into account the best modeling practices developed by Argonne National Laboratory (ANL) and BR2 engineers.« less

  8. Analysis of the Reactor Physics of Low-Enrichment Fuel for the INL Advanced Test Reactor in support of RERTR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mark DeHart; William Skerjanc; Sean Morrell

    2012-06-01

    Analysis of the performance of the ATR with a LEU fuel design shows promise in terms of a core design that will yield the same neutron sources in target locations. A proposed integral cladding burnable absorber design appears to meet power profile requirements that will satisfy power distributions for safety limits. Performance of this fuel design is ongoing; the current work is the initial evaluation of the core performance of this fuel design with increasing burnup. Results show that LEU fuel may have a longer lifetime that HEU fuel however, such limits may be set by mechanical performance of themore » fuel rather that available reactivity. Changes seen in the radial fuel power distribution with burnup in LEU fuel will require further study to ascertain the impact on neutron fluxes in target locations. Source terms for discharged fuel have also been studied. By its very nature, LEU fuel produces much more plutonium than is present in HEU fuel at discharge. However, the effect of the plutonium inventory appears to have little affect on radiotoxicity or decay heat in the fuel.« less

  9. HEU Holdup Measurements on 321-M A-Lathe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewberry, R.A.

    The Analytical Development Section of SRTC was requested by the Facilities Disposition Division (FDD) of the Savannah River Site to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. The 321-M facility was used to fabricate enriched uranium fuel assemblies, lithium-aluminum target tubes, neptunium assemblies, and miscellaneous components for the production reactors. The results of the holdup assays are essential for determining compliance with the solid waste Waste Acceptance Criteria, Material Control and Accountability, and to meet criticality safety controls. Three measurement systems were used to determine highly enrichedmore » uranium (HEU) holdup. This report covers holdup measurements on the A-Lathe that was used to machine uranium-aluminum-alloy (U-Al). Our results indicated that the lathe contained more than the limits stated in the Waste Acceptance Criteria (WAC) for the solid waste E-Area Vaults. Thus the lathe was decontaminated three times and assayed four times in order to bring the amounts of uranium to an acceptable content. This report will discuss the methodology, Non-Destructive Assay (NDA) measurements, and results of the U-235 holdup on the lathe.« less

  10. Review of the TREAT Conversion Conceptual Design and Fuel Qualification Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diamond, David

    The U.S. Department of Energy (DOE) is preparing to re establish the capability to conduct transient testing of nuclear fuels at the Idaho National Laboratory (INL) Transient Reactor Test (TREAT) facility. The original TREAT core went critical in February 1959 and operated for more than 6,000 reactor startups before plant operations were suspended in 1994. DOE is now planning to restart the reactor using the plant's original high-enriched uranium (HEU) fuel. At the same time, the National Nuclear Security Administration (NNSA) Office of Material Management and Minimization Reactor Conversion Program is supporting analyses and fuel fabrication studies that will allowmore » for reactor conversion to low-enriched uranium (LEU) fuel (i.e., fuel with less than 20% by weight 235U content) after plant restart. The TREAT Conversion Program's objectives are to perform the design work necessary to generate an LEU replacement core, to restore the capability to fabricate TREAT fuel element assemblies, and to implement the physical and operational changes required to convert the TREAT facility to use LEU fuel.« less

  11. Challenges in developing e-government for good governance in North Sumatra

    NASA Astrophysics Data System (ADS)

    Siahaan, AY

    2017-01-01

    E-government as one form of public administration reform in Indonesia is increasingly related to the pursuance of good governance. This paper examines the relationship between of e-government and good governance by utilizing the case study design on the implementation of e-procurement in North Sumatra. It reveals centrality of local politics and business culture in understanding resistances of both local government officials and local business which creates loopholes’ for the practice of ‘bad governance’ in all phases of e-procurement in North Sumatra province. Data transparency does not equate and guarantee the realization of good governance. Public knowledge and understanding on government decision making processes and accountability (process and policy transparency) are central to achieve good governance through e-procurement. E-procurement system does not automatically change organizational and working culture of the implementers and suppliers. This paper provides insight to the attitude and the perception of private sector engage in e-procurement towards government in implementing e-government. Resistance, digital divide and local politics interrelatedly obstruct the realization of pursuing good governance through e-procurement.

  12. From Data Poor, Information Poor to Data Rich, Information Rich Decision-Making: Design and Implementation of a Student Information System

    ERIC Educational Resources Information Center

    Burger, John M.; Nadirova, Anna

    2013-01-01

    In this paper, we report on the design and implementation of a state of the art Student Information System (SIS) being developed in a moderate size Alberta, Canada school jurisdiction. The SIS design is premised upon transparency, balanced, comprehensive, and multi-method assessments that links qualitative and quantitative data in support of…

  13. Utilization of multiple-criteria decision analysis (MCDA) to support healthcare decision-making FIFARMA, 2016

    PubMed Central

    Drake, Julia I.; de Hart, Juan Carlos Trujillo; Monleón, Clara; Toro, Walter; Valentim, Joice

    2017-01-01

    ABSTRACT Background and objectives:   MCDA is a decision-making tool with increasing use in the healthcare sector, including HTA (Health Technology Assessment). By applying multiple criteria, including innovation, in a comprehensive, structured and explicit manner, MCDA fosters a transparent, participative, consistent decision-making process taking into consideration values of all stakeholders. This paper by FIFARMA (Latin American Federation of Pharmaceutical Industry) proposes the deliberative (partial) MCDA as a more pragmatic, agile approach, especially when newly implemented. Methods: Literature review including real-world examples of effective MCDA implementation in healthcare decision making in both the public and private sector worldwide and in LA. Results and conclusion: It is the view of FIFARMA that MCDA should strongly be considered as a tool to support HTA and broader healthcare decision making such as the contracts and tenders process in order to foster transparency, fairness, and collaboration amongst stakeholders. PMID:29081919

  14. Dynamically tunable implementation of electromagnetically induced transparency with two coupling graphene-nanostrips in terahertz region

    NASA Astrophysics Data System (ADS)

    Shu, Chang; Chen, Qing-Guo; Mei, Jin-Shuo; Yin, Jing-Hua

    2018-03-01

    In this paper, we numerically demonstrated a dynamically tunable implementation of electromagnetically induced transparency (EIT) response with two coupling graphene-nanostrips in terahertz region. Compared to the metal-based structures or separated graphene structures, the Fermi energies of proposed two coupling graphene-nanostrips can be independently tuned by changing bias voltage between the metallic pads and substrate, the EIT window which appears from the near-field coupling between two resonators can be dynamically tuned without reoptimizing and refabricating the structures. As a result, the EIT window has a significant tunable capacity which can realize a higher frequency modulation depth and control the amplitude of transmission peak at a fixed frequency; moreover, the group delay of transmission peak at a fixed frequency with the amplitude of over 0.95 could be dynamically tuned. These results would exhibit potential applications in modulators and tunable slow light devices.

  15. Atomic Physics Effects on Convergent, Child-Langmuir Ion Flow between Nearly Transparent Electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santarius, John F.; Emmert, Gilbert A.

    Research during this project at the University of Wisconsin Fusion Technology Institute (UW FTI) on ion and neutral flow through an arbitrary, monotonic potential difference created by nearly transparent electrodes accomplished the following: (1) developed and implemented an integral equation approach for atomic physics effects in helium plasmas; (2) extended the analysis to coupled integral equations that treat atomic and molecular deuterium ions and neutrals; (3) implemented the key deuterium and helium atomic and molecular cross sections; (4) added negative ion production and related cross sections; and (5) benchmarked the code against experimental results. The analysis and codes treat themore » species D0, D20, D+, D2+, D3+, D and, separately at present, He0 and He+. Extensions enhanced the analysis and related computer codes to include He++ ions plus planar and cylindrical geometries.« less

  16. Finding Resolution for the Responsible Transparency of Economic Models in Health and Medicine.

    PubMed

    Padula, William V; McQueen, Robert Brett; Pronovost, Peter J

    2017-11-01

    The Second Panel on Cost-Effectiveness in Health and Medicine recommendations for conduct, methodological practices, and reporting of cost-effectiveness analyses has a number of questions unanswered with respect to the implementation of transparent, open source code interface for economic models. The possibility of making economic model source code could be positive and progressive for the field; however, several unintended consequences of this system should be first considered before complete implementation of this model. First, there is the concern regarding intellectual property rights that modelers have to their analyses. Second, the open source code could make analyses more accessible to inexperienced modelers, leading to inaccurate or misinterpreted results. We propose several resolutions to these concerns. The field should establish a licensing system of open source code such that the model originators maintain control of the code use and grant permissions to other investigators who wish to use it. The field should also be more forthcoming towards the teaching of cost-effectiveness analysis in medical and health services education so that providers and other professionals are familiar with economic modeling and able to conduct analyses with open source code. These types of unintended consequences need to be fully considered before the field's preparedness to move forward into an era of model transparency with open source code.

  17. Letting the daylight in: Reviewing the reviewers and other ways to maximize transparency in science

    PubMed Central

    Wicherts, Jelte M.; Kievit, Rogier A.; Bakker, Marjan; Borsboom, Denny

    2012-01-01

    With the emergence of online publishing, opportunities to maximize transparency of scientific research have grown considerably. However, these possibilities are still only marginally used. We argue for the implementation of (1) peer-reviewed peer review, (2) transparent editorial hierarchies, and (3) online data publication. First, peer-reviewed peer review entails a community-wide review system in which reviews are published online and rated by peers. This ensures accountability of reviewers, thereby increasing academic quality of reviews. Second, reviewers who write many highly regarded reviews may move to higher editorial positions. Third, online publication of data ensures the possibility of independent verification of inferential claims in published papers. This counters statistical errors and overly positive reporting of statistical results. We illustrate the benefits of these strategies by discussing an example in which the classical publication system has gone awry, namely controversial IQ research. We argue that this case would have likely been avoided using more transparent publication practices. We argue that the proposed system leads to better reviews, meritocratic editorial hierarchies, and a higher degree of replicability of statistical analyses. PMID:22536180

  18. There Is More to Transparency than Meets the Eye: The Impact of Mandatory Disclosure Laws Aimed at Promoting Breastfeeding.

    PubMed

    Lytton, Timothy D; Dennison, Barbara A; Nguyen, Trang Q; Jurkowski, Janine M

    2014-01-01

    Requiring hospitals to inform patients of clinical best practices and to disclose performance data are two common regulatory strategies for improving healthcare. Proponents of such mandatory disclosure laws--sometimes referred to as "targeted transparency "--argue that they increase patient awareness and thereby create reputational incentives for hospitals to improve their performance. Evaluation of targeted transparency typically focuses on patient responses to information and changes in hospital behavior based on reputational concerns. This standard account, however, overlooks other important ways targeted transparency can influence hospital performance. This article presents a case study of disclosure laws designed to promote breastfeeding to illustrate how targeted transparency can influence hospitals independently of its effects on patients' choice of provider or hospitals' fear of losing business. We found that mandatory disclosure laws emboldened state regulators to take a more aggressive approach to enforcement of hospital regulations, empowered nurse managers to advocate more effectively within hospitals for changes in hospital policies, and enabled nurse managers to implement verifiable performance goals for clinical staff under their supervision. These findings suggest that the study of mandatory disclosure more generally--in areas such as financial regulation, environmental protection, food labeling, and workplace safety--would benefit by analyzing not only its influence on public awareness and its reputational effects but also how regulators use transparency laws and how managers within regulated entities employ the information that the laws provide.

  19. HEU Holdup Measurements in the 321-M Draw Bench, Straightener, and Fluoroscope Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewberry, R.A.

    The Analytical Development Section of Savannah River Technology Center (SRTC) was requested by the Facilities Disposition Division (FDD) to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. This report covers holdup measurements of uranium residue on the draw bench, straightener, and the fluoroscope components of the 321-M facility.

  20. Cyberpeace Through Cyberspace: Nation-Building Against Transnational Terrorism

    DTIC Science & Technology

    2010-12-01

    Haiti,” The Seattle Times, January 27, 2010 at: http://seattletimes.nwsource.com/html/nationworld/2010910268_haiti28.html? syndication =rss (accessed...March 30, 2010 at: http://www.thebulletin.org/web-edition/ columnists /fissile-materials- working-group/reduce-the-civilian-use-of-heu-now (accessed...Bulletin of the Atomic Scientists, March 30, 2010. http://www.thebulletin.org/web- edition/ columnists /fissile-materials-working-group/reduce-the

  1. Body fat distribution in perinatally HIV-infected and HIV-exposed but uninfected children in the era of highly active antiretroviral therapy: outcomes from the Pediatric HIV/AIDS Cohort Study

    USDA-ARS?s Scientific Manuscript database

    Associations between abnormal body fat distribution and clinical variables are poorly understood in pediatric HIV disease. Our objective was to compare total body fat and its distribution in perinatally HIV-infected and HIV-exposed but uninfected (HEU) children and to evaluate associations with clin...

  2. Perovskite Solar Cells with Large-Area CVD-Graphene for Tandem Solar Cells.

    PubMed

    Lang, Felix; Gluba, Marc A; Albrecht, Steve; Rappich, Jörg; Korte, Lars; Rech, Bernd; Nickel, Norbert H

    2015-07-16

    Perovskite solar cells with transparent contacts may be used to compensate for thermalization losses of silicon solar cells in tandem devices. This offers a way to outreach stagnating efficiencies. However, perovskite top cells in tandem structures require contact layers with high electrical conductivity and optimal transparency. We address this challenge by implementing large-area graphene grown by chemical vapor deposition as a highly transparent electrode in perovskite solar cells, leading to identical charge collection efficiencies. Electrical performance of solar cells with a graphene-based contact reached those of solar cells with standard gold contacts. The optical transmission by far exceeds that of reference devices and amounts to 64.3% below the perovskite band gap. Finally, we demonstrate a four-terminal tandem device combining a high band gap graphene-contacted perovskite top solar cell (Eg = 1.6 eV) with an amorphous/crystalline silicon bottom solar cell (Eg = 1.12 eV).

  3. It’s Time to Shine the Light on Direct-to-Consumer Advertising

    PubMed Central

    Mackey, Tim K.; Liang, Bryan A.

    2015-01-01

    Pharmaceutical marketing is undergoing a transition as the business, delivery, and consumption of health care have increasingly become part of a growing digital landscape. Changes in pharmaceutical promotion also coincide with federal “sunshine” regulations newly implemented under the Affordable Care Act that require disclosure of certain marketing and industry payments to physicians. Collectively, these trends could lead to fundamental shifts in physician-directed and direct-to-consumer advertising (DTCA) that have yet to be adequately identified or explored. In response, we advocate for greater DTCA transparency, especially in the emerging digital forms of DTCA, to complement forthcoming sunshine transparency data. This will allow more robust study and understanding of changes in overall pharmaceutical marketing trends and their impact on health care consumption and behavior. This can also lead to more targeted state and federal policy interventions leveraging existing federal transparency regulations to ensure appropriate marketing, sales, and consumption of pharmaceutical products. PMID:25583897

  4. Self-activated ultrahigh chemosensitivity of oxide thin film nanostructures for transparent sensors

    PubMed Central

    Moon, Hi Gyu; Shim, Young-Soek; Kim, Do Hong; Jeong, Hu Young; Jeong, Myoungho; Jung, Joo Young; Han, Seung Min; Kim, Jong Kyu; Kim, Jin-Sang; Park, Hyung-Ho; Lee, Jong-Heun; Tuller, Harry L.; Yoon, Seok-Jin; Jang, Ho Won

    2012-01-01

    One of the top design priorities for semiconductor chemical sensors is developing simple, low-cost, sensitive and reliable sensors to be built in handheld devices. However, the need to implement heating elements in sensor devices, and the resulting high power consumption, remains a major obstacle for the realization of miniaturized and integrated chemoresistive thin film sensors based on metal oxides. Here we demonstrate structurally simple but extremely efficient all oxide chemoresistive sensors with ~90% transmittance at visible wavelengths. Highly effective self-activation in anisotropically self-assembled nanocolumnar tungsten oxide thin films on glass substrate with indium-tin oxide electrodes enables ultrahigh response to nitrogen dioxide and volatile organic compounds with detection limits down to parts per trillion levels and power consumption less than 0.2 microwatts. Beyond the sensing performance, high transparency at visible wavelengths creates opportunities for their use in transparent electronic circuitry and optoelectronic devices with avenues for further functional convergence. PMID:22905319

  5. DebtRank-transparency: Controlling systemic risk in financial networks

    PubMed Central

    Thurner, Stefan; Poledna, Sebastian

    2013-01-01

    Nodes in a financial network, such as banks, cannot assess the true risks associated with lending to other nodes in the network, unless they have full information on the riskiness of all other nodes. These risks can be estimated by using network metrics (as DebtRank) of the interbank liability network. With a simple agent based model we show that systemic risk in financial networks can be drastically reduced by increasing transparency, i.e. making the DebtRank of individual banks visible to others, and by imposing a rule, that reduces interbank borrowing from systemically risky nodes. This scheme does not reduce the efficiency of the financial network, but fosters a more homogeneous risk-distribution within the system in a self-organized critical way. The reduction of systemic risk is due to a massive reduction of cascading failures in the transparent system. A regulation-policy implementation of the proposed scheme is discussed. PMID:23712454

  6. Negotiating action

    NASA Astrophysics Data System (ADS)

    2017-12-01

    After years of working towards a climate accord, the Paris Agreement of 2015 marked the shift from negotiating to reach consensus on climate action to implementation of such action. The challenge now is to ensure transparency in the processes and identify the details of what is required.

  7. Engagement of scientific community and transparency in C accounting: the Brazilian case for anthropogenic greenhouse gas emissions from land use, land-use change and forestry

    NASA Astrophysics Data System (ADS)

    Bustamante, M. M. C.; Silva, J. S. O.; Cantinho, R. Z.; Shimbo, J. Z.; Oliveira, P. V. C.; Santos, M. M. O.; Ometto, J. P. H. B.; Cruz, M. R.; Mello, T. R. B.; Godiva, D.; Nobre, C. A.

    2018-05-01

    To effectively implement the Paris Agreement, capacity in carbon accounting must be strengthened in the developing world, and partnerships with local academic institutions can do the accounting for governments and fill the capacity gap. This paper highlights the Brazilian case, focusing on ways in which climate change science information and transparency are being incorporated in national C accounting initiatives, particularly the national inventory of greenhouse gas (GHG) emissions and removals. We report how the third inventory for the sector of land use, land-use change and forestry (LULUCF) was implemented to address scientific challenges involved in the monitoring of carbon stocks and land-use changes of diverse and complex biomes while addressing international and national policy demands (report and decision support) and transparency to various stakeholders. GHG emissions and removals associated with 2002–2010 carbon changes in aboveground, belowground biomass, necromass and soil carbon by land use and land cover changes were estimated for all Brazilian biomes, and for the Amazon estimates were also presented for the periods of 2002–2005 and 2005–2010. The inventory improved regional estimates for carbon stock and national emission factors with the support and engagement of the scientific community. Incorporation of local context is essential to reduce uncertainties and properly monitor efforts to contribute to GHG emission/reduction targets. To promote transparency and make information more accessible, the national inventory results were made available by the National Emissions Registry System (SIRENE). This system was built to support climate change policies as an important legal apparatus and by increasing access to emissions and land-use change data.

  8. Photoresist-Free Patterning by Mechanical Abrasion of Water-Soluble Lift-Off Resists and Bare Substrates: Toward Green Fabrication of Transparent Electrodes

    PubMed Central

    Printz, Adam D.; Chan, Esther; Liong, Celine; Martinez, René S.; Lipomi, Darren J.

    2013-01-01

    This paper describes the fabrication of transparent electrodes based on grids of copper microwires using a non-photolithographic process. The process—“abrasion lithography”—takes two forms. In the first implementation (Method I), a water-soluble commodity polymer film is abraded with a sharp tool, coated with a conductive film, and developed by immersion in water. Water dissolves the polymer film and lifts off the conductive film in the unabraded areas. In the second implementation (Method II), the substrate is abraded directly by scratching with a sharp tool (i.e., no polymer film necessary). The abraded regions of the substrate are recessed and roughened. Following deposition of a conductive film, the lower profile and roughened topography in the abraded regions prevents mechanical exfoliation of the conductive film using adhesive tape, and thus the conductive film remains only where the substrate is scratched. As an application, conductive grids exhibit average sheet resistances of 17 Ω sq–1 and transparencies of 86% are fabricated and used as the anode in organic photovoltaic cells in concert with the conductive polymer, poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Compared to devices in which PEDOT:PSS alone serves as an anode, devices comprising grids of copper/nickel microwires and PEDOT:PSS exhibit lowered series resistance, which manifests in greater fill factor and power conversion efficiency. This simple method of forming micropatterns could find use in applications where cost and environmental impact should be minimized, especially as a potential replacement for the transparent electrode indium tin oxide (ITO) in thin-film electronics over large areas (i.e., solar cells) or as a method of rapid prototyping for laboratory-scale devices. PMID:24358321

  9. [Evaluation of methodological quality in published RCTs on cataract surgery : Pilot study on the degree of adherence to CONSORT statement requirements and their qualitative validity].

    PubMed

    Baulig, C; Krummenauer, F; Knippschild, S

    2018-01-01

    The CONSORT statement can be considered as a guideline to ensure transparency in the reporting of randomized clinical trials (RCT), in addition to specific author instructions and requirements of journals. It provides a total of 25 criteria and 12 additional subcriteria on methodological and regulatorical determinants of clinical trials. The availability of the CONSORT recommendations, however, does not necessarily imply adherence to their obligations and correct realisation of the latter from a methodological perspective, so that even in ophthalmology a lack of transparency in trial reporting cannot be excluded. The question was whether a consistent consideration of the CONSORT checklist criteria by authors actually implied transparent reporting of underlying study results. This pilot study was based on a random sample of six published RCTs on cataract surgery extracted from an existing trial publication register. Compliance with each of the 25 CONSORT criteria and its 12 subcriteria and the content accuracy of the latter were independently assessed by two parallel raters for the six trial publications. The median compliance with the 37 CONSORT criteria and subcriteria was 62% [min-max 48-81%]; the median fraction of their correct implementation was 47% [min-max 34-69%]. Promotion of transparent reporting by means of the CONSORT statement appears to be problematic in implementation. There is a discrepancy between information as required by CONSORT and the content accuracy of its actual presentation. Thus, in particular, reviewers of clinical trial publications should not only check for the presence of data to be provided according to CONSORT, but also verify the meaningfulness in the respective context, at least on a random basis.

  10. Photoresist-free patterning by mechanical abrasion of water-soluble lift-off resists and bare substrates: toward green fabrication of transparent electrodes.

    PubMed

    Printz, Adam D; Chan, Esther; Liong, Celine; Martinez, René S; Lipomi, Darren J

    2013-01-01

    This paper describes the fabrication of transparent electrodes based on grids of copper microwires using a non-photolithographic process. The process--"abrasion lithography"--takes two forms. In the first implementation (Method I), a water-soluble commodity polymer film is abraded with a sharp tool, coated with a conductive film, and developed by immersion in water. Water dissolves the polymer film and lifts off the conductive film in the unabraded areas. In the second implementation (Method II), the substrate is abraded directly by scratching with a sharp tool (i.e., no polymer film necessary). The abraded regions of the substrate are recessed and roughened. Following deposition of a conductive film, the lower profile and roughened topography in the abraded regions prevents mechanical exfoliation of the conductive film using adhesive tape, and thus the conductive film remains only where the substrate is scratched. As an application, conductive grids exhibit average sheet resistances of 17 Ω sq(-1) and transparencies of 86% are fabricated and used as the anode in organic photovoltaic cells in concert with the conductive polymer, poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Compared to devices in which PEDOT:PSS alone serves as an anode, devices comprising grids of copper/nickel microwires and PEDOT:PSS exhibit lowered series resistance, which manifests in greater fill factor and power conversion efficiency. This simple method of forming micropatterns could find use in applications where cost and environmental impact should be minimized, especially as a potential replacement for the transparent electrode indium tin oxide (ITO) in thin-film electronics over large areas (i.e., solar cells) or as a method of rapid prototyping for laboratory-scale devices.

  11. Application Transparent HTTP Over a Disruption Tolerant Smartnet

    DTIC Science & Technology

    2014-09-01

    American Standard Code for Information Interchange BP Bundle Protocol BPA bundle protocol agent CLA convergence layer adapters CPU central processing...forwarding them through the plugin pipeline. The initial version of the DTNInput plugin uses the BBN Spindle bundle protocol agent ( BPA ) implementation

  12. The Proliferation Security Initiative: A Means to an End for the Operational Commander

    DTIC Science & Technology

    2009-05-04

    The Reduced Enrichment for Research and Test Reactors ( RERTR ) Program develops technology necessary to enable the conversion of civilian...facilities using high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The RERTR Program was initiated by the U.S. Department of...processes have been developed for producing radioisotopes with LEU targets. The RERTR Program is managed by the Office of Nuclear Material Threat

  13. Reducing the Threat of Nuclear Terrorism- A Report Card on the Obama Administration’s Efforts

    DTIC Science & Technology

    2016-12-01

    using methods that did not require HEU and the recovery of roughly 750 radioisotope thermoelectric...Office of Management and Budget, Paperwork Reduction Project (0704-0188) Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE ...December 2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE REDUCING THE THREAT OF NUCLEAR TERRORISM—A REPORT CARD ON

  14. Developing and implementing a computerized nursing quality control system in a tertiary general medical center in Israel.

    PubMed

    Kagan, Ilya; Cohen, Rachel; Fish, Miri; Mezare, Henia Perry

    2014-01-01

    This article describes the development and implementation of the Nursing Quality Indicators Scale and a quality control system for hospital nursing care, which allows universal access to all external and internal audit results, thus ensuring complete data transparency. Standardized indicators make departments' performance comparable. Key to the new system is nurses' self-audit and responsibility for making quality improvements at the ward level.

  15. Status of reduced enrichment programs for research reactors in Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanda, Keiji; Nishihara, Hedeaki; Shirai, Eiji

    1997-08-01

    The reduced enrichment programs for the JRR-2, JRR-3, JRR-4 and JMTR of Japan Atomic Energy Research Institute (JAERI), and the KUR of Kyoto University Research Reactor Institute (KURRI) have been partially completed and are mostly still in progress under the Joint Study Programs with Argonne National Laboratory (ANL). The JMTR and JRR-2 have been already converted to use MEU aluminide fuels in 1986 and 1987, respectively. The operation of the upgraded JRR-3(JRR-3M) has started in March 1990 with the LEU aluminide fuels. Since May 1992, the two elements have been inserted in the KUR. The safety review application for themore » full core conversion to use LEU silicide in the JMTR was approved in February 1992 and the conversion has been done in January 1994. The Japanese Government approved a cancellation of the KUHFR Project in February 1991, and in April 1994 the U.S. Government gave an approval to utilize HEU in the KUR instead of the KUHFR. Therefore, the KUR will be operated with HEU fuel until 2001. Since March 1994, Kyoto University is continuing negotiation with UKAEA Dounreay on spent fuel reprocessing and blending down of recovered uranium, in addition to that with USDOE.« less

  16. Uranium: Prices, rise, then fall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pool, T.C.

    Uranium prices hit eight-year highs in both market tiers,more » $$16.60/lb U{sub 3}O{sub 8} for non-former Soviet Union (FSU) origin and $$15.50 for FSU origin during mid 1996. However, they declined to $14.70 and $13.90, respectively, by the end of the year. Increased uranium prices continue to encourage new production and restarts of production facilities presently on standby. Australia scrapped its {open_quotes}three-mine{close_quotes} policy following the ouster of the Labor party in a March election. The move opens the way for increasing competition with Canada`s low-cost producers. Other events in the industry during 1996 that have current or potential impacts on the market include: approval of legislation outlining the ground rules for privatization of the US Enrichment Corp. (USEC) and the subsequent sales of converted Russian highly enriched uranium (HEU) from its nuclear weapons program, announcement of sales plans for converted US HEU and other surplus material through either the Department of Energy or USEC, and continuation of quotas for uranium from the FSU in the United States and Europe. In Canada, permitting activities continued on the Cigar Lake and McArthur River projects; and construction commenced on the McClean Lake mill.« less

  17. Air Shipment of Highly Enriched Uranium Spent Nuclear Fuel from Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. J. Allen; I. Bolshinsky; L. L. Biro

    2010-07-01

    Romania safely air shipped 23.7 kilograms of Russian origin highly enriched uranium (HEU) spent nuclear fuel from the VVR S research reactor at Magurele, Romania, to the Russian Federation in June 2009. This was the world’s first air shipment of spent nuclear fuel transported in a Type B(U) cask under existing international laws without special exceptions for the air transport licenses. This shipment was coordinated by the Russian Research Reactor Fuel Return Program (RRRFR), part of the U.S. Department of Energy Global Threat Reduction Initiative (GTRI), in cooperation with the Romania National Commission for Nuclear Activities Control (CNCAN), the Horiamore » Hulubei National Institute of Physics and Nuclear Engineering (IFIN-HH), and the Russian Federation State Corporation Rosatom. The shipment was transported by truck to and from the respective commercial airports in Romania and the Russian Federation and stored at a secure nuclear facility in Russia where it will be converted into low enriched uranium. With this shipment, Romania became the 3rd country under the RRRFR program and the 14th country under the GTRI program to remove all HEU. This paper describes the work, equipment, and approvals that were required to complete this spent fuel air shipment.« less

  18. Thermal properties for the thermal-hydraulics analyses of the BR2 maximum nominal heat flux.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dionne, B.; Kim, Y. S.; Hofman, G. L.

    2011-05-23

    This memo describes the assumptions and references used in determining the thermal properties for the various materials used in the BR2 HEU (93% enriched in {sup 235}U) to LEU (19.75% enriched in {sup 235}U) conversion feasibility analysis. More specifically, this memo focuses on the materials contained within the pressure vessel (PV), i.e., the materials that are most relevant to the study of impact of the change of fuel from HEU to LEU. This section is regrouping all of the thermal property tables. Section 2 provides a summary of the thermal properties in form of tables while the following sections presentmore » the justification of these values. Section 3 presents a brief background on the approach used to evaluate the thermal properties of the dispersion fuel meat and specific heat capacity. Sections 4 to 7 discuss the material properties for the following materials: (i) aluminum, (ii) dispersion fuel meat (UAlx-Al and U-7Mo-Al), (iii) beryllium, and (iv) stainless steel. Section 8 discusses the impact of irradiation on material properties. Section 9 summarizes the material properties for typical operating temperatures. Appendix A elaborates on how to calculate dispersed phase's volume fraction. Appendix B shows the evolution of the BR2 maximum heat flux with burnup.« less

  19. Dynamic System Simulation of the KRUSTY Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, Steven Karl; Kimpland, Robert Herbert

    2016-05-09

    The proposed KRUSTY experiment is a demonstration of a reactor operating at power. The planned experimental configuration includes a highly enriched uranium (HEU) reflected core, cooled by multiple heat pipes leading to Stirling engines for primary heat rejection. Operating power is expected to be approximately four (4) to five (5) kilowatts with a core temperature above 1,000 K. No data is available on any historical reactor employing HEU metal that operated over the temperature range required for the KRUSTY experiment. Further, no reactor has operated with heat pipes as the primary cooling mechanism. Historic power reactors have employed either naturalmore » or forced convection so data on their operation is not directly applicable to the KRUSTY experiment. The primary purpose of the system model once developed and refined by data from these component experiments, will be used to plan the KRUSTY experiment. This planning will include expected behavior of the reactor from start-up, through various transient conditions where cooling begins to become present and effective, and finally establishment of steady-state. In addition, the model can provide indicators of anticipated off-normal events and appropriate operator response to those conditions. This information can be used to develop specific experiment operating procedures and aids to guide the operators in conduct of the experiment.« less

  20. Overview and Current Status of Analyses of Potential LEU Design Concepts for TREAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connaway, H. M.; Kontogeorgakos, D. C.; Papadias, D. D.

    2015-10-01

    Neutronic and thermal-hydraulic analyses have been performed to evaluate the performance of different low-enriched uranium (LEU) fuel design concepts for the conversion of the Transient Reactor Test Facility (TREAT) from its current high-enriched uranium (HEU) fuel. TREAT is an experimental reactor developed to generate high neutron flux transients for the testing of nuclear fuels. The goal of this work was to identify an LEU design which can maintain the performance of the existing HEU core while continuing to operate safely. A wide variety of design options were considered, with a focus on minimizing peak fuel temperatures and optimizing the powermore » coupling between the TREAT core and test samples. Designs were also evaluated to ensure that they provide sufficient reactivity and shutdown margin for each control rod bank. Analyses were performed using the core loading and experiment configuration of historic M8 Power Calibration experiments (M8CAL). The Monte Carlo code MCNP was utilized for steady-state analyses, and transient calculations were performed with the point kinetics code TREKIN. Thermal analyses were performed with the COMSOL multi-physics code. Using the results of this study, a new LEU Baseline design concept is being established, which will be evaluated in detail in a future report.« less

  1. Analysis of Loss-of-Coolant Accidents in the NIST Research Reactor - Early Phase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baek, Joo S.; Diamond, David

    A study of the fuel temperature during the early phase of a loss-of-coolant accident (LOCA) in the NIST research reactor (NBSR) was completed. Previous studies had been reported in the preliminary safety analysis report for the conversion of the NBSR from high-enriched uranium (HEU) fuel to low-enriched (LEU) fuel. Those studies had focused on the most vulnerable LOCA situation, namely, a double-ended guillotine break in the time period after reactor trip when water is drained from either the coolant channels inside the fuel elements or the region outside the fuel elements. The current study fills in a gap in themore » analysis which is the early phase of the event when there may still be water present but the reactor is at power or immediately after reactor trip and pumps have tripped. The calculations were done, for both the current HEU-fueled core and the proposed LEU core, with the TRACE thermal-hydraulic systems code. Several break locations and different break sizes were considered. In all cases the increase in the clad (or fuel meat) temperature was relatively small so that a large margin to the temperature threshold for blistering (the Safety Limit for the NBSR) remained.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, James; Goins, Monty; Paul, Pran

    This safety analysis report for packaging (SARP) presents the results of the safety analysis prepared in support of the Consolidated Nuclear Security, LLC (CNS) request for licensing of the Model ES-3100 package with bulk highly enriched uranium (HEU) contents and issuance of a Type B(U) Fissile Material Certificate of Compliance. This SARP, published in the format specified in the Nuclear Regulatory Commission (NRC) Regulatory Guide 7.9 and using information provided in UCID-21218 and NRC Regulatory Guide 7.10, demonstrates that the Y-12 National Security Complex (Y-12) ES-3100 package with bulk HEU contents meets the established NRC regulations for packaging, preparation formore » shipment, and transportation of radioactive materials given in Title 10, Part 71, of the Code of Federal Regulations (CFR) [10 CFR 71] as well as U.S. Department of Transportation (DOT) regulations for packaging and shipment of hazardous materials given in Title 49 CFR. To protect the health and safety of the public, shipments of adioactive materials are made in packaging that is designed, fabricated, assembled, tested, procured, used, maintained, and repaired in accordance with the provisions cited above. Safety requirements addressed by the regulations that must be met when transporting radioactive materials are containment of radioactive materials, radiation shielding, and assurance of nuclear subcriticality.« less

  3. Multiple transparency windows and Fano interferences induced by dipole-dipole couplings

    NASA Astrophysics Data System (ADS)

    Diniz, E. C.; Borges, H. S.; Villas-Boas, C. J.

    2018-04-01

    We investigate the optical properties of a two-level system (TLS) coupled to a one-dimensional array of N other TLSs with dipole-dipole coupling between the first neighbors. The first TLS is probed by a weak field, and we assume that it has a decay rate much greater than the decay rates of the other TLSs. For N =1 and in the limit of a Rabi frequency of a probe field much smaller than the dipole-dipole coupling, the optical response of the first TLS, i.e., its absorption and dispersion, is equivalent to that of a three-level atomic system in the configuration which allows one to observe the electromagnetically induced transparency (EIT) phenomenon. Thus, here we investigate an induced transparency phenomenon where the dipole-dipole coupling plays the same role as the control field in EIT in three-level atoms. We describe this physical phenomenon, named a dipole-induced transparency (DIT), and investigate how it scales with the number of coupled TLSs. In particular, we have shown that the number of TLSs coupled to the main TLS is exactly equal to the number of transparency windows. The ideas presented here are very general and can be implemented in different physical systems, such as an array of superconducting qubits, or an array of quantum dots, spin chains, optical lattices, etc.

  4. Standardization of blood smears prepared in transparent acetate: an alternative method for the microscopic diagnosis of malaria.

    PubMed

    Mello, Marcia B C; Luz, Francisco C; Leal-Santos, Fabio A; Alves, Eduardo R; Gasquez, Thamires M; Fontes, Cor J F

    2014-06-17

    Due to students' initial inexperience, slides are frequently broken and blood smears are damaged in microscopy training, leading to the need for their constant replacement. To minimize this problem a method of preparing blood smears on transparent acetate sheets was developed with the goal of implementing appropriate and more readily available teaching resources for the microscopic diagnosis of malaria. Acetate sheets derived from polyester were used to standardize the preparation and staining of thin and thick blood smears on transparent acetate sheets. Thick and thin blood smears were also prepared using the conventional method on glass slides. The staining was conducted using Giemsa staining for the thick and thin smears. Microscopic examination (1,000x) of the thin and thick blood smears prepared on transparent acetate produced high-quality images for both the parasites and the blood cells. The smears showed up on a clear background and with minimal dye precipitation. It was possible to clearly identify the main morphological characteristics of Plasmodium, neutrophils and platelets. After 12 months of storage, there was no change in image quality or evidence of fungal colonization. Preparation of thin and thick blood smears in transparent acetate for the microscopic diagnosis of malaria does not compromise the morphological and staining characteristics of the parasites or blood cells. It is reasonable to predict the applicability of transparent acetate in relevant situations such as the training of qualified professionals for the microscopic diagnosis of malaria and the preparation of positive specimens for competency assessment (quality control) of professionals and services involved in the diagnosis of malaria.

  5. Demonstration of an advanced solar garden with a water ceiling. Six-month technical progress report, July 1-December 31, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maes, R.; Riseng, C.; Thomas, G.

    1980-02-01

    A history of the solar garden with the addition of the transparent water ceiling and a statement of the overall goals of the program are presented. It then details the objectives of the water ceiling grant. The rationale of the transparent water ceiling is developed and its implementation in the solar garden is described. The experimental procedures for evaluating the water ceiling as an integral part of an ongoing garden agricultural experiment are discussed. The results of the first six months of the program and the future activities of the next period are presented.

  6. Are Key Principles for improved health technology assessment supported and used by health technology assessment organizations?

    PubMed

    Neumann, Peter J; Drummond, Michael F; Jönsson, Bengt; Luce, Bryan R; Schwartz, J Sanford; Siebert, Uwe; Sullivan, Sean D

    2010-01-01

    Previously, our group-the International Working Group for HTA Advancement-proposed a set of fifteen Key Principles that could be applied to health technology assessment (HTA) programs in different jurisdictions and across a range of organizations and perspectives. In this commentary, we investigate the extent to which these principles are supported and used by fourteen selected HTA organizations worldwide. We find that some principles are broadly supported: examples include being explicit about HTA goals and scope; considering a wide range of evidence and outcomes; and being unbiased and transparent. Other principles receive less widespread support: examples are addressing issues of generalizability and transferability; being transparent on the link between HTA findings and decision-making processes; considering a full societal perspective; and monitoring the implementation of HTA findings. The analysis also suggests a lack of consensus in the field about some principles--for example, considering a societal perspective. Our study highlights differences in the uptake of key principles for HTA and indicates considerable room for improvement for HTA organizations to adopt principles identified to reflect good HTA practices. Most HTA organizations espouse certain general concepts of good practice--for example, assessments should be unbiased and transparent. However, principles that require more intensive follow-up--for example, monitoring the implementation of HTA findings--have received little support and execution.

  7. Transparent Large-Area MoS2 Phototransistors with Inkjet-Printed Components on Flexible Platforms.

    PubMed

    Kim, Tae-Young; Ha, Jewook; Cho, Kyungjune; Pak, Jinsu; Seo, Jiseok; Park, Jongjang; Kim, Jae-Keun; Chung, Seungjun; Hong, Yongtaek; Lee, Takhee

    2017-10-24

    Two-dimensional (2D) transition-metal dichalcogenides (TMDCs) have gained considerable attention as an emerging semiconductor due to their promising atomically thin film characteristics with good field-effect mobility and a tunable band gap energy. However, their electronic applications have been generally realized with conventional inorganic electrodes and dielectrics implemented using conventional photolithography or transferring processes that are not compatible with large-area and flexible device applications. To facilitate the advantages of 2D TMDCs in practical applications, strategies for realizing flexible and transparent 2D electronics using low-temperature, large-area, and low-cost processes should be developed. Motivated by this challenge, we report fully printed transparent chemical vapor deposition (CVD)-synthesized monolayer molybdenum disulfide (MoS 2 ) phototransistor arrays on flexible polymer substrates. All the electronic components, including dielectric and electrodes, were directly deposited with mechanically tolerable organic materials by inkjet-printing technology onto transferred monolayer MoS 2 , and their annealing temperature of <180 °C allows the direct fabrication on commercial flexible substrates without additional assisted-structures. By integrating the soft organic components with ultrathin MoS 2 , the fully printed MoS 2 phototransistors exhibit excellent transparency and mechanically stable operation.

  8. The Impact of Price Transparency for Surgical Services.

    PubMed

    Mehta, Ambar; Xu, Tim; Bai, Ge; Hawley, Kristy L; Makary, Martin A

    2018-04-01

    Increasing insurance deductibles have prompted some medical centers to initiate transparent pricing. However, the impact of price transparency (PT) on surgical volume, revenue, and patient satisfaction is unknown, along with the barriers to achieving PT. We identified ambulatory surgical centers in the Free Market Medical Association database that publicly list prices for surgical services online. Six of eight centers (75%) responded to our data collection inquiry. Among five centers that reported their patient volume and revenue after adopting PT, patient volume increased by a median of 50 per cent (range 10-200%) at one year. Four centers (80%) reported an increase in revenue by a median of 30 per cent (range 4-75%), whereas three centers (60%) experienced an increase in third-party administrator contracts with the average increase being seven new third-party administrator contracts (range = 2-12 contracts). Three centers (50%) reported a reduction in their administrative burden and five centers (83%) reported an increase in patient satisfaction and patient engagement after PT. The leading barrier reported to making prices transparent was discouragement from another practice, hospital, or insurance company. The findings of this preliminary study may help guide medical practices in designing and implementing PT strategies.

  9. Implementing Infrastructures for Managing Learning Objects

    ERIC Educational Resources Information Center

    Klemke, Roland; Ternier, Stefaan; Kalz, Marco; Specht, Marcus

    2010-01-01

    Making learning objects available is critical to reuse learning resources. Making content transparently available and providing added value to different stakeholders is among the goals of the European Commission's eContentplus programme. This paper analyses standards and protocols relevant for making learning objects accessible in distributed data…

  10. 75 FR 20298 - Privacy Act Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-19

    ... Part 200 RIN 0430-AA03 Privacy Act Regulations AGENCY: Recovery Accountability and Transparency Board... amend the Board's regulations implementing the Privacy Act of 1974 (Privacy Act), as amended. This proposed rule would exempt certain systems of records from certain sections of the Privacy Act. These...

  11. Overview of Nonelectronic Eye-Gaze Communication Techniques.

    ERIC Educational Resources Information Center

    Goossens, Carol A.; Crain, Sharon S.

    1987-01-01

    The article discusses currently used eye gaze communication techniques with the severely physically disabled (eye-gaze vest, laptray, transparent display, and mirror/prism communicator), presents information regarding the types of message displays used to depict encoded material, and discusses the advantages of implementing nonelectronic eye-gaze…

  12. 77 FR 37456 - Self-Regulatory Organizations; Chicago Mercantile Exchange, Inc.; Notice of Filing and Order...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... the policies underlying the Act, including, for example, promoting market transparency for derivatives... a derivatives clearing organization with the Commodity Futures Trading Commission (''CFTC'') and... derivatives clearing organization, is implementing the proposed changes in furtherance with applicable CFTC...

  13. The Faculty Costs to Educate a Biomedical Sciences Graduate Student

    ERIC Educational Resources Information Center

    Smolka, Adam J.; Halushka, Perry V.; Garrett-Mayer, Elizabeth

    2015-01-01

    Academic medical centers nationwide face numerous fiscal challenges resulting from implementation of restructured healthcare delivery models, contracting state support for higher education, and increased competition for federal and other sources of biomedical research funding. In pursuing greater accountability and transparency in its fiscal…

  14. TICK: Transparent Incremental Checkpointing at Kernel Level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrini, Fabrizio; Gioiosa, Roberto

    2004-10-25

    TICK is a software package implemented in Linux 2.6 that allows the save and restore of user processes, without any change to the user code or binary. With TICK a process can be suspended by the Linux kernel upon receiving an interrupt and saved in a file. This file can be later thawed in another computer running Linux (potentially the same computer). TICK is implemented as a Linux kernel module, in the Linux version 2.6.5

  15. Defense Health Care Reform: Additional Implementation Details Would Increase Transparency of DOD’s Plans and Enhance Accountability

    DTIC Science & Technology

    2013-11-01

    on timelines; and was not required to include information on shared services because the reporting time frame was not applicable. GAO also assessed...implementation costs and aggregated cost-savings estimates for the consolidation of four shared services . However, some key details of a sound business...case were missing, such as the basis for the savings. DOD’s business cases aggregated the separate business lines of its shared services , which

  16. Improving Transparency in the Reporting of Safeguards Implementation: FY11 Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toomey, Christopher; Odlaug, Christopher S.; Wyse, Evan T.

    2011-09-30

    In 2008, the Standing Advisory Group on Safeguards Implementation (SAGSI) indicated that the International Atomic Energy Agency's (IAEA) Safeguards Implementation Report (SIR) has not kept pace with the evolution of safeguards and provided the IAEA with a set of recommendations for improvement. The SIR is the primary mechanism for providing an overview of safeguards implementation in a given year and reporting on the annual safeguards findings and conclusions drawn by the Secretariat. As the IAEA transitions to State-level safeguards approaches, SIR reporting must adapt to reflect these evolutionary changes. This evolved report will better reflect the IAEA's transition to amore » more qualitative and information-driven approach, based upon State-as-a-whole considerations. This paper applies SAGSI's recommendations to the development of multiple models for an evolved SIR and finds that an SIR repurposed as a 'safeguards portal' could significantly enhance information delivery, clarity, and transparency. In addition, this paper finds that the 'portal concept' also appears to have value as a standardized information presentation and analysis platform for use by Country Officers, for continuity of knowledge purposes, and the IAEA Secretariat in the safeguards conclusion process. Accompanying this paper is a fully functional prototype of the 'portal' concept, built using commercial software and IAEA Annual Report data and available for viewing at http://safeguardsportal.pnnl.gov.« less

  17. Nuclear Safeguards and the International Atomic Energy Agency

    DTIC Science & Technology

    1995-01-01

    designed to use HEU, the tite safeguards agreement already in place for cen- RERTR (Reduced Enrichment for Research and trifuge facilities (which allows only...notice in- types. Many such reactors have been converted. spections, such as provided for under the Hexa- (See discussion below on the RERTR program...the Schumer amendment to the United States was developing suitable alternate 19Some believe that the suspension of the RERTR program may have been a

  18. Are We Doing Enough to Prevent a Nuclear Terrorist Attack?

    DTIC Science & Technology

    2013-03-01

    grams of Cesium-137 which they suspected was smuggled to Turkey from Russia through Georgia.18 Of more interest are the reported cases of smuggling...required to assemble a nuclear weapon.19 However, this does not necessarily tell the entire story . For instance, according to a Czech police 11...investigation of a 1994 seizure in Prague of 2.7 kilograms of Russian -origin highly enriched uranium (HEU),20 smugglers claimed they could deliver

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luther, Erik Paul; Leckie, Rafael M.; Dombrowski, David E.

    This supplemental report describes fuel fabrication efforts conducted for the Idaho National Laboratory Trade Study for the TREAT Conversion project that is exploring the replacement of the HEU (Highly Enriched Uranium) fuel core of the TREAT reactor with LEU (Low Enriched Uranium) fuel. Previous reports have documented fabrication of fuel by the “upgrade” process developed at Los Alamos National Laboratory. These experiments supplement an earlier report that describes efforts to increase the graphite content of extruded fuel and minimize cracking.

  20. Nuclear Terrorism: Calibrating Funding for Defensive Programs in Response to the Threat

    DTIC Science & Technology

    2009-12-01

    fertilizer , ceramic tile, and bananas, slow the cargo screening process and in some cases have even led officials to reduce the sensitivity settings...kilograms of HEU or 8 kilograms of plutonium (weights roughly equated to the size of a melon and a plum respectively).234 Terrorists would likely...ed. Schwartz, 214. 69 On February 26, 1993, terrorists detonated 1,400 pounds of fertilizer -based explosives in the underground parking garage of

  1. Pakistan’s Nuclear Weapons: Proliferation and Security Issues

    DTIC Science & Technology

    2009-12-09

    Nuclear Terrorism in Pakistan: Sabotage of a Spent Fuel Cask or a Commercial Irradiation Source in Transport ,” in Pakistan’s Nuclear Future, 2008...gave additional urgency to the program. Pakistan produced fissile material for its nuclear weapons using gas-centrifuge-based uranium enrichment...technology, which it mastered by the mid-1980s. Highly-enriched uranium (HEU) is one of two types of fissile material used in nuclear weapons; the other

  2. Thermal Analysis of a TREAT Fuel Assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papadias, Dionissios; Wright, Arthur E.

    2014-07-09

    The objective of this study was to explore options as to reduce peak cladding temperatures despite an increase in peak fuel temperatures. A 3D thermal-hydraulic model for a single TREAT fuel assembly was benchmarked to reproduce results obtained with previous thermal models developed for a TREAT HEU fuel assembly. In exercising this model, and variants thereof depending on the scope of analysis, various options were explored to reduce the peak cladding temperatures.

  3. Student Motivation for NAPLAN Tests

    ERIC Educational Resources Information Center

    Belcastro, Lauren; Boon, Helen

    2012-01-01

    The current "Education Revolution" in Australia has witnessed the shift to greater accountability in outcomes, transparency in practice, and comparable data at a national level. The National Assessment Program as endorsed by MYCEEDYA and implemented by ACARA, has come to encompass NAPLAN testing, which was quick to become a household…

  4. Making a Library Catalog Adaptive.

    ERIC Educational Resources Information Center

    Buckland, Michael K.; And Others

    1992-01-01

    Describes the design of a prototype adaptive online catalog that was implemented as a transparent workstation-based front end system to MELVYL, the online catalog for the University of California libraries. Problems with searching bibliographic retrieval systems are reviewed, including irrelevant retrievals and the inexperience of most users.…

  5. Learning Outcomes in Professional Contexts in Higher Education

    ERIC Educational Resources Information Center

    Prøitz, Tine S.; Havnes, Anton; Briggs, Mary; Scott, Ian

    2017-01-01

    With the policy of developing a transparent and competitive European higher education sector, learning outcomes (LOs) are attributed a foundation stone role in policy and curriculum development. A premise for their implementation is that they bear fundamental similarities across national, institutional or professional/disciplinary contexts. In…

  6. Addressing Phonological Questions with Ultrasound

    ERIC Educational Resources Information Center

    Davidson, Lisa

    2005-01-01

    Ultrasound can be used to address unresolved questions in phonological theory. To date, some studies have shown that results from ultrasound imaging can shed light on how differences in phonological elements are implemented. Phenomena that have been investigated include transitional schwa, vowel coalescence, and transparent vowels. A study of…

  7. 76 FR 16587 - Risk Management Requirements for Derivatives Clearing Organizations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-24

    ... COMMODITY FUTURES TRADING COMMISSION 17 CFR Part 39 RIN 3038-AC98 Risk Management Requirements for... other things, would implement DCO Core Principle D (Risk Management) and would establish a related... framework to reduce risk, increase transparency, and promote market integrity within the financial system...

  8. Temperature Profile in Fuel and Tie-Tubes for Nuclear Thermal Propulsion Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vishal Patel

    A finite element method to calculate temperature profiles in heterogeneous geometries of tie-tube moderated LEU nuclear thermal propulsion systems and HEU designs with tie-tubes is developed and implemented in MATLAB. This new method is compared to previous methods to demonstrate shortcomings in those methods. Typical methods to analyze peak fuel centerline temperature in hexagonal geometries rely on spatial homogenization to derive an analytical expression. These methods are not applicable to cores with tie-tube elements because conduction to tie-tubes cannot be accurately modeled with the homogenized models. The fuel centerline temperature directly impacts safety and performance so it must be predictedmore » carefully. The temperature profile in tie-tubes is also important when high temperatures are expected in the fuel because conduction to the tie-tubes may cause melting in tie-tubes, which may set maximum allowable performance. Estimations of maximum tie-tube temperature can be found from equivalent tube methods, however this method tends to be approximate and overly conservative. A finite element model of heat conduction on a unit cell can model spatial dependence and non-linear conductivity for fuel and tie-tube systems allowing for higher design fidelity of Nuclear Thermal Propulsion.« less

  9. Transparent Fingerprint Sensor System for Large Flat Panel Display.

    PubMed

    Seo, Wonkuk; Pi, Jae-Eun; Cho, Sung Haeung; Kang, Seung-Youl; Ahn, Seong-Deok; Hwang, Chi-Sun; Jeon, Ho-Sik; Kim, Jong-Uk; Lee, Myunghee

    2018-01-19

    In this paper, we introduce a transparent fingerprint sensing system using a thin film transistor (TFT) sensor panel, based on a self-capacitive sensing scheme. An armorphousindium gallium zinc oxide (a-IGZO) TFT sensor array and associated custom Read-Out IC (ROIC) are implemented for the system. The sensor panel has a 200 × 200 pixel array and each pixel size is as small as 50 μm × 50 μm. The ROIC uses only eight analog front-end (AFE) amplifier stages along with a successive approximation analog-to-digital converter (SAR ADC). To get the fingerprint image data from the sensor array, the ROIC senses a capacitance, which is formed by a cover glass material between a human finger and an electrode of each pixel of the sensor array. Three methods are reviewed for estimating the self-capacitance. The measurement result demonstrates that the transparent fingerprint sensor system has an ability to differentiate a human finger's ridges and valleys through the fingerprint sensor array.

  10. Transparent Fingerprint Sensor System for Large Flat Panel Display

    PubMed Central

    Seo, Wonkuk; Pi, Jae-Eun; Cho, Sung Haeung; Kang, Seung-Youl; Ahn, Seong-Deok; Hwang, Chi-Sun; Jeon, Ho-Sik; Kim, Jong-Uk

    2018-01-01

    In this paper, we introduce a transparent fingerprint sensing system using a thin film transistor (TFT) sensor panel, based on a self-capacitive sensing scheme. An armorphousindium gallium zinc oxide (a-IGZO) TFT sensor array and associated custom Read-Out IC (ROIC) are implemented for the system. The sensor panel has a 200 × 200 pixel array and each pixel size is as small as 50 μm × 50 μm. The ROIC uses only eight analog front-end (AFE) amplifier stages along with a successive approximation analog-to-digital converter (SAR ADC). To get the fingerprint image data from the sensor array, the ROIC senses a capacitance, which is formed by a cover glass material between a human finger and an electrode of each pixel of the sensor array. Three methods are reviewed for estimating the self-capacitance. The measurement result demonstrates that the transparent fingerprint sensor system has an ability to differentiate a human finger’s ridges and valleys through the fingerprint sensor array. PMID:29351218

  11. Private governance, public purpose? Assessing transparency and accountability in self-regulation of food advertising to children.

    PubMed

    Reeve, Belinda

    2013-06-01

    Reducing non-core food advertising to children is an important priority in strategies to address childhood obesity. Public health researchers argue for government intervention on the basis that food industry self-regulation is ineffective; however, the industry contends that the existing voluntary scheme adequately addresses community concerns. This paper examines the operation of two self-regulatory initiatives governing food advertising to children in Australia, in order to determine whether these regulatory processes foster transparent and accountable self-regulation. The paper concludes that while both codes appear to establish transparency and accountability mechanisms, they do not provide for meaningful stakeholder participation in the self-regulatory scheme. Accordingly, food industry self-regulation is unlikely to reflect public health concerns or to be perceived as a legitimate form of governance by external stakeholders. If industry regulation is to remain a feasible alternative to statutory regulation, there is a strong argument for strengthening government oversight and implementing a co-regulatory scheme.

  12. E-Government Attempts in Small Island Developing States: The Rate of Corruption with Virtualization.

    PubMed

    Sari, Arif

    2017-12-01

    In recent years, many Small Island Developing State (SIDS) governments have worked to increase openness and transparency of their transactions as a means to enhance efficiency and reduce corruption in their economies. In order to achieve a cost-effective and efficient strategy to implement a transparent government, Information Communication Technologies offer an opportunity of virtualization by deploying e-government services to promote transparency, accountability and consistency in the public sector and to minimize corruption. This paper explores the potential impact of government virtualization by SIDS and against corruption by comparing the corruption perception index (CPI) rates of 15 SIDS countries. The CPI relates to the degree by which corruption is perceived to exist among public officials and politicians by business people and country analysts. In order to reveal the long-term impact of virtual deployment and its consequences on corruption, an in-depth case analysis based on the CPI index rates was conducted on the deployment of the e-government system in Cyprus.

  13. A GPU accelerated PDF transparency engine

    NASA Astrophysics Data System (ADS)

    Recker, John; Lin, I.-Jong; Tastl, Ingeborg

    2011-01-01

    As commercial printing presses become faster, cheaper and more efficient, so too must the Raster Image Processors (RIP) that prepare data for them to print. Digital press RIPs, however, have been challenged to on the one hand meet the ever increasing print performance of the latest digital presses, and on the other hand process increasingly complex documents with transparent layers and embedded ICC profiles. This paper explores the challenges encountered when implementing a GPU accelerated driver for the open source Ghostscript Adobe PostScript and PDF language interpreter targeted at accelerating PDF transparency for high speed commercial presses. It further describes our solution, including an image memory manager for tiling input and output images and documents, a PDF compatible multiple image layer blending engine, and a GPU accelerated ICC v4 compatible color transformation engine. The result, we believe, is the foundation for a scalable, efficient, distributed RIP system that can meet current and future RIP requirements for a wide range of commercial digital presses.

  14. It's time to shine the light on direct-to-consumer advertising.

    PubMed

    Mackey, Tim K; Liang, Bryan A

    2015-01-01

    Pharmaceutical marketing is undergoing a transition as the business, delivery, and consumption of health care have increasingly become part of a growing digital landscape. Changes in pharmaceutical promotion also coincide with federal "sunshine" regulations newly implemented under the Affordable Care Act that require disclosure of certain marketing and industry payments to physicians. Collectively, these trends could lead to fundamental shifts in physician-directed and direct-to-consumer advertising (DTCA) that have yet to be adequately identified or explored. In response, we advocate for greater DTCA transparency, especially in the emerging digital forms of DTCA, to complement forthcoming sunshine transparency data. This will allow more robust study and understanding of changes in overall pharmaceutical marketing trends and their impact on health care consumption and behavior. This can also lead to more targeted state and federal policy interventions leveraging existing federal transparency regulations to ensure appropriate marketing, sales, and consumption of pharmaceutical products. © 2015 Annals of Family Medicine, Inc.

  15. Fiscal Year 2007 Performance and Accountability Report

    ERIC Educational Resources Information Center

    US Department of Education, 2007

    2007-01-01

    This document represents the annual report card of the U.S. Department of Education's efforts and outcomes during fiscal year 2007. This year's report builds on efforts to increase transparency, and more effectively communicate goals and objectives. The report emphasizes achievements and challenges associated with implementing the Department of…

  16. The Volpe Center GPS Adjacent Band Compatibility Program Plan : GPS Adjacent Band Compatibility Workshop, Volpe Center, Cambridge MA

    DOT National Transportation Integrated Search

    2014-09-18

    Approach to DOT GPS Adjacent Band Compatibility Assessment. Identify forums and provide public outreach to make sure the progress and work are as open and transparent as possible. Develop an implementation plan that incorporates aspects from the DOT ...

  17. Voice-Based Technology for Parent Involvement: Results and Effects.

    ERIC Educational Resources Information Center

    Bauch, Jerold P.

    A study was conducted to implement and evaluate the Transparent School Model for improving parent involvement in nine Indiana schools. The Model uses computer-based voice messaging to exchange information between teachers and parents. Teachers record a brief message for parents that describes what was taught, special learning events, homework…

  18. Schools Are for All Kids. Part II: School Site Implementation. Trainer's Packet.

    ERIC Educational Resources Information Center

    Roger, Blair; And Others

    This trainer's packet, designed to be used in conjunction with the participant's manual, was prepared for a 2-day workshop to restructure schools to embrace all children, including those with disabilities. The trainer's materials include: program objectives; masters for overhead transparencies; and descriptions of learning activities, including…

  19. Designing and Researching Technology-Enhanced Learning for the Zone of Proximal Implementation

    ERIC Educational Resources Information Center

    McKenney, Susan

    2013-01-01

    Internationally, society is increasingly demanding that the relevance and practical applicability of research be made transparent. Despite intentions to the contrary, insights on pedagogically appropriate uses of educational technology for representative teachers in everyday school settings are severely limited. In part, this is because (design)…

  20. 77 FR 27502 - Self-Regulatory Organizations; Chicago Mercantile Exchange Inc.; Notice of Filing and Order...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-10

    ... number of the policies underlying the Exchange Act, such as promoting market transparency for derivatives... Statutory Basis for, the Proposed Rule Change CME is registered as a derivatives clearing organization with... number of new regulations designed to implement the core principles for derivatives clearing...

  1. Five year neurodevelopment outcomes of perinatally HIV-infected children on early limited or deferred continuous antiretroviral therapy.

    PubMed

    Laughton, Barbara; Cornell, Morna; Kidd, Martin; Springer, Priscilla Estelle; Dobbels, Els Françoise Marie-Thérèse; Rensburg, Anita Janse Van; Otwombe, Kennedy; Babiker, Abdel; Gibb, Diana M; Violari, Avy; Kruger, Mariana; Cotton, Mark Fredric

    2018-05-01

    Early antiretroviral therapy (ART) has improved neurodevelopmental outcomes of HIV-infected (HIV-positive) children; however, little is known about the longer term outcomes in infants commencing early ART or whether temporary ART interruption might have long-term consequences. In the children with HIV early antiretroviral treatment (CHER) trial, HIV-infected infants ≤12 weeks of age with CD4 ≥25% were randomized to deferred ART (ART-Def); immediate time-limited ART for 40 weeks (ART-40W) or 96 weeks (ART-96W). ART was restarted in the time-limited arms for immunologic/clinical progression. Our objective was to compare the neurodevelopmental profiles in all three arms of Cape Town CHER participants. A prospective, longitudinal observational study was used. The Griffiths mental development scales (GMDS), which includes six subscales and a global score, were performed at 11, 20, 30, 42 and 60 months, and the Beery-Buktenica developmental tests for visual motor integration at 60 months. HIV-exposed uninfected (HEU) and HIV-unexposed (HU) children were enrolled for comparison. Mixed model repeated measures were used to compare groups over time, using quotients derived from standardized British norms. In this study, 28 ART-Def, 35 ART-40W, 33 ART-96W CHER children, and 34 HEU and 39 HU controls were enrolled. GMDS scores over five years were similar between the five groups in all subscales except locomotor and general Griffiths (interaction p < 0.001 and p = 0.02 respectively), driven by early lower scores in the ART-Def arm. At 60 months, scores for all groups were similar in each GMDS scale. However, Beery visual perception scores were significantly lower in HIV-infected children (mean standard scores: 75.8 ART-Def, 79.8 ART-40W, 75.9 ART-96W) versus 84.4 in HEU and 90.5 in HU (p < 0.01)). Early locomotor delay in the ART-Def arm resolved by five years. Neurodevelopmental outcomes at five years in HIV-infected children on early time-limited ART were similar to uninfected controls, apart from visual perception where HIV-infected children scored lower. Poorer visual perception performance warrants further investigation. © 2018 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  2. Validation and uncertainty quantification of detector response functions for a 1″×2″ NaI collimated detector intended for inverse radioisotope source mapping applications

    NASA Astrophysics Data System (ADS)

    Nelson, N.; Azmy, Y.; Gardner, R. P.; Mattingly, J.; Smith, R.; Worrall, L. G.; Dewji, S.

    2017-11-01

    Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF's constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45-65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart's Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

  3. The Effect of U-234 Content on the Neutronic Behavior of Uranium Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busch, Robert D.; Bledsoe, Keith C

    2011-01-01

    When analyzing uranium systems, the usual rule of thumb is to ignore the U-234 by assuming that it behaves neutronically like U-238. Thus for uranium systems, the uranium is evaluated as U-235 with everything else being U-238. The absorption cross section of U-234 is indeed qualitatively very similar to that of U-238. However, thermal absorption cross section of U-234 is about 100 times that of U-238. At low U-235 enrichments, the amount of U-234 is quite small so the impact of assuming it is U-238 is minimal. However, at high enrichments, the relative ratio of U-234 to U-238 is quitemore » large (maybe as much as 1 to 5). Thus, one would expect that some effect of using the rule of thumb might be seen in higher enriched systems. Analyses were performed on three uranium systems from the set of Benchmarks [1]. Although the benchmarks are adequately characterized as to the U-234 content, often, materials used in processing are not as well characterized. This issue may become more important with the advent of laser enrichment processes, which have little or no effect on the U-234 content. Analytical results based on the relationship of U-234 activity to that of U-235 have shown good predictive capability but with large variability in the uncertainties [2]. Rucker and Johnson noted that the actual isotopics vary with enrichment, design of the enrichment cascade, composition of the feed material, and on blending of enrichments so there is considerable uncertainty in the use of models to determine isotopics. Thus, it is important for criticality personnel to understand the effects of variation of U-234 content in fissile systems and the impact of different modeling assumptions in handling the U-234. Analyses were done on LEU, IEU and HEU benchmarks from the International Handbook. These indicate that the effect of ignoring U-234 in HEU metal systems is non-conservative while it seems to be conservative for HEU solution systems. The magnitude of change in k-effective was as high as 0.4%, which has implications on selection of administrative margins and the determination of the upper subcriticality limit.« less

  4. Unsupervised learning of contextual constraints in neural networks for simultaneous visual processing of multiple objects

    NASA Astrophysics Data System (ADS)

    Marshall, Jonathan A.

    1992-12-01

    A simple self-organizing neural network model, called an EXIN network, that learns to process sensory information in a context-sensitive manner, is described. EXIN networks develop efficient representation structures for higher-level visual tasks such as segmentation, grouping, transparency, depth perception, and size perception. Exposure to a perceptual environment during a developmental period serves to configure the network to perform appropriate organization of sensory data. A new anti-Hebbian inhibitory learning rule permits superposition of multiple simultaneous neural activations (multiple winners), while maintaining contextual consistency constraints, instead of forcing winner-take-all pattern classifications. The activations can represent multiple patterns simultaneously and can represent uncertainty. The network performs parallel parsing, credit attribution, and simultaneous constraint satisfaction. EXIN networks can learn to represent multiple oriented edges even where they intersect and can learn to represent multiple transparently overlaid surfaces defined by stereo or motion cues. In the case of stereo transparency, the inhibitory learning implements both a uniqueness constraint and permits coactivation of cells representing multiple disparities at the same image location. Thus two or more disparities can be active simultaneously without interference. This behavior is analogous to that of Prazdny's stereo vision algorithm, with the bonus that each binocular point is assigned a unique disparity. In a large implementation, such a NN would also be able to represent effectively the disparities of a cloud of points at random depths, like human observers, and unlike Prazdny's method

  5. An Integrated Framework for Gender Equity in Academic Medicine.

    PubMed

    Westring, Alyssa; McDonald, Jennifer M; Carr, Phyllis; Grisso, Jeane Ann

    2016-08-01

    In 2008, the National Institutes of Health funded 14 R01 grants to study causal factors that promote and support women's biomedical careers. The Research Partnership on Women in Biomedical Careers, a multi-institutional collaboration of the investigators, is one product of this initiative.A comprehensive framework is needed to address change at many levels-department, institution, academic community, and beyond-and enable gender equity in the development of successful biomedical careers. The authors suggest four distinct but interrelated aspects of culture conducive to gender equity: equal access to resources and opportunities, minimizing unconscious gender bias, enhancing work-life balance, and leadership engagement. They review the collection of eight articles in this issue, which each address one or more of the four dimensions of culture. The articles suggest that improving mentor-mentee fit, coaching grant reviewers on unconscious bias, and providing equal compensation and adequate resources for career development will contribute positively to gender equity in academic medicine.Academic medicine must adopt an integrated perspective on culture for women and acknowledge the multiple facets essential to gender equity. To effect change, culture must be addressed both within and beyond academic health centers (AHCs). Leaders within AHCs must examine their institutions' processes, resources, and assessment for fairness and transparency; mobilize personnel and financial resources to implement evidence-based initiatives; and assign accountability for providing transparent progress assessments. Beyond AHCs, organizations must examine their operations and implement change to ensure parity of funding, research, and leadership opportunities as well as transparency of assessment and accreditation.

  6. Transparency in the reporting of in vivo pre-clinical pain research: The relevance and implications of the ARRIVE (Animal Research: Reporting In Vivo Experiments) guidelines.

    PubMed

    Rice, Andrew S C; Morland, Rosemary; Huang, Wenlong; Currie, Gillian L; Sena, Emily S; Macleod, Malcolm R

    2017-12-29

    Clear reporting of research is crucial to the scientific process. Poorly designed and reported studies are damaging not only to the efforts of individual researchers, but also to science as a whole. Standardised reporting methods, such as those already established for reporting randomised clinical trials, have led to improved study design and facilitated the processes of clinical systematic review and meta-analysis. Such standards were lacking in the pre-clinical field until the development of the ARRIVE (Animal Research: Reporting In Vivo Experiments) guidelines. These were prompted following a survey which highlighted a widespread lack of robust and consistent reporting of pre-clinical in vivo research, with reports frequently omitting basic information required for study replication and quality assessment. The resulting twenty item checklist in ARRIVE covers all aspects of experimental design with particular emphasis on bias reduction and methodological transparency. Influential publishers and research funders have already adopted ARRIVE. Further dissemination and acknowledgement of the importance of these guidelines is vital to their widespread implementation. Conclusions and implications Wide implementation of the ARRIVE guidelines for reporting of in vivo preclinical research, especially pain research, are essential for a much needed increased transparency and quality in publishing such research. ARRIVE will also positively influence improvements in experimental design and quality, assist the conduct of accurate replication studies of important new findings and facilitate meta-analyses of preclinical research.

  7. High-performance NiO/Ag/NiO transparent electrodes for flexible organic photovoltaic cells.

    PubMed

    Xue, Zhichao; Liu, Xingyuan; Zhang, Nan; Chen, Hong; Zheng, Xuanming; Wang, Haiyu; Guo, Xiaoyang

    2014-09-24

    Transparent electrodes with a dielectric-metal-dielectric (DMD) structure can be implemented in a simple manufacturing process and have good optical and electrical properties. In this study, nickel oxide (NiO) is introduced into the DMD structure as a more appropriate dielectric material that has a high conduction band for electron blocking and a low valence band for efficient hole transport. The indium-free NiO/Ag/NiO (NAN) transparent electrode exhibits an adjustable high transmittance of ∼82% combined with a low sheet resistance of ∼7.6 Ω·s·q(-1) and a work function of 5.3 eV after UVO treatment. The NAN electrode shows excellent surface morphology and good thermal, humidity, and environmental stabilities. Only a small change in sheet resistance can be found after NAN electrode is preserved in air for 1 year. The power conversion efficiencies of organic photovoltaic cells with NAN electrodes deposited on glass and polyethylene terephthalate (PET) substrates are 6.07 and 5.55%, respectively, which are competitive with those of indium tin oxide (ITO)-based devices. Good photoelectric properties, the low-cost material, and the room-temperature deposition process imply that NAN electrode is a striking candidate for low-cost and flexible transparent electrode for efficient flexible optoelectronic devices.

  8. Validation of COG10 and ENDFB6R7 on the Auk Workstation for General Application to Highly Enriched Uranium Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Percher, Catherine G.

    2011-08-08

    The COG 10 code package1 on the Auk workstation is now validated with the ENBFB6R7 neutron cross section library for general application to highly enriched uranium (HEU) systems by comparison of the calculated keffective to the expected keffective of several relevant experimental benchmarks. This validation is supplemental to the installation and verification of COG 10 on the Auk workstation2.

  9. Boeing Michigan Aeronautical Research Center (BOMARC) Missile Shelters and Bunkers Scoping Survey Workplan

    DTIC Science & Technology

    2007-08-01

    Characterization (OHM 1998). From the plot, it is clear that the HEU dominates DU in the overall isotopic characteristic. Among the three uranium ... isotopes , 234U comprised about 90 % of the total activity, including naturally-occurring background sources. However, in comparison to the WGP, uranium ...listed for a few sampling locations that had isotopic plutonium analysis of wipe samples. Figure A-19 contains a scatterplot of the paired Table 4-13

  10. Consolidated Canadian Results to the HEU Round Robin Exercise

    DTIC Science & Technology

    2004-11-01

    Niemeyer S, Dudder GB. "Model action plan for nuclear forensics and nuclear attribution." Lawrence Livermore National Laboratory Report UCRL -TR...section 8.) including special warning terms if applicable) Defence R&D Canada - Ottawa 3701 Carling Avenue UNCLASSIFIED Ottawa, ON K IA 0Z4 3. TITLE (the...development. Include the address.) DRDC Ottawa 3701 Carling Avenue K I AOZ4 9a. PROJECT OR GRANT NO. (if appropriate, the applicable research 9b. CONTRACT

  11. Nuclear Power’s Global Expansion: Weighing Its Costs and Risks

    DTIC Science & Technology

    2010-12-01

    collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE DEC 2010 2. REPORT TYPE 3. DATES COVERED 00-00...precisely the ones that industry says will come on line by 2025, the date the current nuclear insurance liability limits under Price-Anderson...United States, the handful of remaining HEU-fueled plants receive government funding. This should end by establishing a date certain for these few

  12. Neutronic study on conversion of SAFARI-1 to LEU silicide fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ball, G.; Pond, R.; Hanan, N.

    1995-02-01

    This paper marks the initial study into the technical and economic feasibility of converting the SAFARI-1 reactor in South Africa to LEU silicide fuel. Several MTR assembly geometries and LEU uranium densities have been studied and compared with MEU and HEU fuels. Two factors of primary importance for conversion of SAFARI-1 to LEU fuel are the economy of the fuel cycle and the performance of the incore and excore irradiation positions.

  13. Update On The Development, Testing, And Manufacture Of High Density LEU-Foil Targets For The Production Of Mo-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Creasy, John T

    2015-05-12

    This project has the objective to reduce and/or eliminate the use of HEU in commerce. Steps in the process include developing a target testing methodology that is bounding for all Mo-99 target irradiators, establishing a maximum target LEU-foil mass, developing a LEU-foil target qualification document, developing a bounding target failure analysis methodology (failure in reactor containment), optimizing safety vs. economics (goal is to manufacture a safe, but relatively inexpensive target to offset the inherent economic disadvantage of using LEU in place of HEU), and developing target material specifications and manufacturing QC test criteria. The slide presentation is organized under themore » following topics: Objective, Process Overview, Background, Team Structure, Key Achievements, Experiment and Activity Descriptions, and Conclusions. The High Density Target project has demonstrated: approx. 50 targets irradiated through domestic and international partners; proof of concept for two front end processing methods; fabrication of uranium foils for target manufacture; quality control procedures and steps for manufacture; multiple target assembly techniques; multiple target disassembly devices; welding of targets; thermal, hydraulic, and mechanical modeling; robust target assembly parametric studies; and target qualification analysis for insertion into very high flux environment. The High Density Target project has tested and proven several technologies that will benefit current and future Mo-99 producers.« less

  14. International Technical Working Group Round Robin Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dudder, Gordon B.; Hanlen, Richard C.; Herbillion, Georges M.

    The goal of nuclear forensics is to develop a preferred approach to support illicit trafficking investigations. This approach must be widely understood and accepted as credible. The principal objectives of the Round Robin Tests are to prioritize forensic techniques and methods, evaluate attribution capabilities, and examine the utility of database. The HEU (Highly Enriched Uranium) Round Robin, and previous Plutonium Round Robin, have made tremendous contributions to fulfilling these goals through a collaborative learning experience that resulted from the outstanding efforts of the nine participating internal laboratories. A prioritized list of techniques and methods has been developed based on thismore » exercise. Current work is focused on the extent to which the techniques and methods can be generalized. The HEU Round Robin demonstrated a rather high level of capability to determine the important characteristics of the materials and processes using analytical methods. When this capability is combined with the appropriate knowledge/database, it results in a significant capability to attribute the source of the materials to a specific process or facility. A number of shortfalls were also identified in the current capabilities including procedures for non-nuclear forensics and the lack of a comprehensive network of data/knowledge bases. The results of the Round Robin will be used to develop guidelines or a ''recommended protocol'' to be made available to the interested authorities and countries to use in real cases.« less

  15. SAFARI-1: Achieving conversion to LEU - A local challenge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piani, C.S.B.

    2008-07-15

    Two years have passed since the South African Department of Minerals and Energy authorised the conversion from High Enriched Uranium (HEU) to Low Enriched Uranium (LEU) of the South African Research Reactor (SAFARI-1) and the associated fuel manufacturing at Pelindaba. The scheduling, as originally proposed, allowed approximately three years for the full conversion of the reactor, anticipating simultaneous manufacturing ability from the fuel production plant. Due to technical difficulties experienced in the conversion of the local manufacturing plant from HEU (UAl alloy) to LEU (U Silicide) and the uncertainty as to costing and scheduling of such an achievement, the conversionmore » of SAFARI-1 based on local supply has been allocated a lower priority. The acquisition in mid-2006 of 2 LEU silicide elements of SA design, manufactured by AREVA- CERCA and irradiated as test elements in SAFARI-1 to burn-ups of {approx}65% each; was successfully accomplished within 9 cycles of irradiation each. Furthermore, four 'Hybrid' elements (AREVA-CERCA plates assembled locally at Pelindaba) are ready for irradiation and have received regulatory authorisation to load. This will enable the SAFARI-1 conversion program to continue systematically according to an agreed schedule. This paper will trace the developments of the above and reflect the current status and the rescheduled conversion phases of the reactor according to latest expectations. (author)« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Margaret A. Marshall

    In the early 1970’s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950’s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared withmore » the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files.” (Reference 1) While performing the ORSphere experiments care was taken to accurately document component dimensions (±0. 0001 in. for non-spherical parts), masses (±0.01 g), and material data The experiment was also set up to minimize the amount of structural material in the sphere proximity. A three part sphere was initially assembled with an average radius of 3.4665 in. and was then machined down to an average radius of 3.4420 in. (3.4425 in. nominal). These two spherical configurations were evaluated and judged to be acceptable benchmark experiments; however, the two experiments are highly correlated.« less

  17. Aligning clinical compensation with clinical productivity: design and implementation of the financial value unit (FVU) system in an academic department of internal medicine.

    PubMed

    Stites, Steven; Steffen, Patrick; Turner, Scott; Pingleton, Susan

    2013-07-01

    A new metric was developed and implemented at the University of Kansas School of Medicine Department of Internal Medicine, the financial value unit (FVU). This metric analyzes faculty clinical compensation compared with clinical work productivity as a transparent means to decrease the physician compensation variability and compensate faculty equitably for clinical work.The FVU is the ratio of individual faculty clinical compensation compared with their total work relative value units (wRVUs) generated divided by Medical Group Management Association (MGMA) salary to wRVUs of a similar MGMA physician.The closer the FVU ratio is to 1.0, the closer clinical compensation is to that of an MGMA physician with similar clinical productivity. Using FVU metrics to calculate a faculty salary gap compared with MGMA median salary and wRVU productivity, a divisional production payment was established annually.From FY 2006 to FY 2011, both total faculty numbers and overall clinical activity increased. With the implementation of the FVU, both clinical productivity and compensation increased while, at the same time, physician retention rates remained high. Variability in physician compensation decreased. Dramatic clinical growth was associated with the alignment of clinical work and clinical compensation in a transparent and equable process.

  18. Improving the Transparency of IAEA Safeguards Reporting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toomey, Christopher; Hayman, Aaron M.; Wyse, Evan T.

    2011-07-17

    In 2008, the Standing Advisory Group on Safeguards Implementation (SAGSI) indicated that the International Atomic Energy Agency's (IAEA) Safeguards Implementation Report (SIR) has not kept pace with the evolution of safeguards and provided the IAEA with a set of recommendations for improvement. The SIR is the primary mechanism for providing an overview of safeguards implementation in a given year and reporting on the annual safeguards findings and conclusions drawn by the Secretariat. As the IAEA transitions to State-level safeguards approaches, SIR reporting must adapt to reflect these evolutionary changes. This evolved report will better reflect the IAEA's transition to amore » more qualitative and information-driven approach, based upon State-as-a-whole considerations. This paper applies SAGSI's recommendations to the development of multiple models for an evolved SIR and finds that an SIR repurposed as a 'safeguards portal' could significantly enhance information delivery, clarity, and transparency. In addition, this paper finds that the 'portal concept' also appears to have value as a standardized information presentation and analysis platform for use by Country Officers, for continuity of knowledge purposes, and the IAEA Secretariat in the safeguards conclusion process. Accompanying this paper is a fully functional prototype of the 'portal' concept, built using commercial software and IAEA Annual Report data.« less

  19. Implementing guidelines on reporting research using animals (ARRIVE etc.): new requirements for publication in BJP

    PubMed Central

    McGrath, John C; Lilley, Elliot

    2015-01-01

    The ARRIVE guidelines have been implemented in BJP for 4 years with the aim of increasing transparency in reporting experiments involving animals. BJP has assessed our success in implementing them and concluded that we could do better. This editorial discusses the issues and explains how we are changing our requirements for authors to report their findings in experiments involving animals. This is one of a series of editorials discussing updates to the BJP Instructions to Authors Video To view the video on the ARRIVE guidelines, visit: https://www.youtube.com/watch?v=DYXoUAnhoPM PMID:25964986

  20. An universal read-out controller

    NASA Astrophysics Data System (ADS)

    Manz, S.; Abel, N.; Gebelein, J.; Kebschull, U.

    2010-11-01

    Since 2007 we design and develop a ROC (read-out controller) for FAIR's data-acquisition. While our first implementation solely focused on the nXYTER, today we are also designing and implementing readout logic for the GET4 which is supposed to be part of the ToF detector. Furthermore, we fully support both Ethernet and Optical transport as two transparent solutions. The usage of a strict modularization of the Read Out Controller enables us to provide an Universal ROC where front-end specific logic and transport logic can be combined in a very flexible way. Fault tolerance techniques are only required for some of those modules and hence are only implemented there.

  1. Competences as the Core Element of the European Qualifications Framework

    ERIC Educational Resources Information Center

    Bohlinger, Sandra

    2008-01-01

    The development and implementation of the EQF, as a meta-framework for the promotion of transparency, quality assurance, mobility and mutual recognition of qualifications, has given rise to some difficulties. These are due partly to different definitions of competences, skills and knowledge. Taking the German-speaking countries as an example, the…

  2. The Values Awareness Teaching Strategy; An Overview.

    ERIC Educational Resources Information Center

    Dalis, Gus T.; Strasser, Ben B.

    The transcript of a values awareness lesson in communicable diseases is presented to illustrate the two stages of a typical values class--introducing the lesson and implementing the lesson. In this case, an overhead slide-transparency is used (along with prefacing remarks) to lead the class into considering those whom a gonorrhea-infected youth…

  3. 75 FR 55663 - Requirements for Federal Funding Accountability and Transparency Act Implementation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ...: Provision of health services. A Federal program provides funding to State agencies to deliver a variety of....g., mental health services) that is authorized under the program and the State otherwise might...: Research. An agency makes an award to a university to investigate basic physics to understand why certain...

  4. Descriptors for Competence: Towards an International Standard Classification for Skills and Competences

    ERIC Educational Resources Information Center

    Markowitsch, Jorg; Plaimauer, Claudia

    2009-01-01

    Purpose: The purpose of this paper is to investigate the potential of already existing skills and competence ontologies to benefit European transparency tools and especially the implementation of the European Qualification Framework. Furthermore, it asks whether any of them could serve as a starting point to develop an International Standard…

  5. Impact of the Shodan Computer Search Engine on Internet-facing Industrial Control System Devices

    DTIC Science & Technology

    2014-03-27

    bridge implementation. The transparent bridge is designed using a Raspberry Pi configured with Linux IPtables and bridge-utils to bridge the on board...Ethernet card and a second USB Ethernet adapter. A Raspberry Pi is a credit-card-sized single-board computer running a version of Debian Linux. There

  6. Improving Finance for Qatari Education Reform. Research Brief

    ERIC Educational Resources Information Center

    Guarino, Cassandra M.; Galama, Titus; Constant, Louay; Gonzalez, Gabriella; Tanner, Jeffery C.; Goldman, Charles A.

    2009-01-01

    Qatar's education reform, which included implementation of a new finance system, appears to be providing schools with adequate funding but is still struggling with issues of transparency and swift policy shifts that have been difficult to accommodate. [For full report, "Developing a School Finance System for K-12 Reform in Qatar", see…

  7. 75 FR 64173 - Notice of Proposed Rulemaking Implementing Certain Orderly Liquidation Authority Provisions of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-19

    ... Title II reflects the Dodd-Frank Act's mandate of transparency in the liquidation of failing systemic... in all other cases. This procedure is similar to that which is applied to systemic risk... payments will be enforced. Parties who are familiar with the liquidation of insured depository institutions...

  8. Quality Assurance in Australian Higher Education: Historical and Future Development

    ERIC Educational Resources Information Center

    Shah, Mahsood; Nair, Sid; Wilson, Mark

    2011-01-01

    Higher education policies related to quality assurance are implemented in many countries. The purposes of such policies are to ensure the provision for high-quality education, university accountability and transparency in the use of public funding and meeting the needs of the diverse stakeholders. The current Australian Higher Education Quality…

  9. 77 FR 27530 - Self-Regulatory Organizations; Chicago Mercantile Exchange Inc.; Notice of Filing and Order...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-10

    ... number of the policies underlying the Exchange Act, such as promoting market transparency for derivatives... Statutory Basis for, the Proposed Rule Change CME is registered as a derivatives clearing organization with... adopted a number of new regulations designed to implement the core principles for derivatives clearing...

  10. Learner-Content-Interface as an Approach for Self-Reliant and Student-Centered Learning

    ERIC Educational Resources Information Center

    Nicolay, Robin; Schwennigcke, Bastian; Sahl, Sarah; Martens, Alke

    2015-01-01

    Conceptualization and implementation of computer supported teaching and training is currently not tailored to the paradigm of learner centration. Many technical solutions lack transparency and consistency regarding the supported learner activities. An insight into learners activities correlated to learning tasks is needed. In this paper we outline…

  11. Implementing LCFF: Communicating about District Plans. Policy and Practice Brief

    ERIC Educational Resources Information Center

    Knudson, Joel

    2016-01-01

    California educators continue in their struggle to communicate district plans to parents, teachers, and other members of the school community. Local Control Accountability Plans (LCAPs), have ballooned into jargon-laden stacks of tables, impenetrable to all but the most sophisticated reader. Envisioned as a tool to improve transparency, the LCAP…

  12. Informing Environmental Water Management Decisions: Using Conditional Probability Networks to Address the Information Needs of Planning and Implementation Cycles.

    PubMed

    Horne, Avril C; Szemis, Joanna M; Webb, J Angus; Kaur, Simranjit; Stewardson, Michael J; Bond, Nick; Nathan, Rory

    2018-03-01

    One important aspect of adaptive management is the clear and transparent documentation of hypotheses, together with the use of predictive models (complete with any assumptions) to test those hypotheses. Documentation of such models can improve the ability to learn from management decisions and supports dialog between stakeholders. A key challenge is how best to represent the existing scientific knowledge to support decision-making. Such challenges are currently emerging in the field of environmental water management in Australia, where managers are required to prioritize the delivery of environmental water on an annual basis, using a transparent and evidence-based decision framework. We argue that the development of models of ecological responses to environmental water use needs to support both the planning and implementation cycles of adaptive management. Here we demonstrate an approach based on the use of Conditional Probability Networks to translate existing ecological knowledge into quantitative models that include temporal dynamics to support adaptive environmental flow management. It equally extends to other applications where knowledge is incomplete, but decisions must still be made.

  13. Informing Environmental Water Management Decisions: Using Conditional Probability Networks to Address the Information Needs of Planning and Implementation Cycles

    NASA Astrophysics Data System (ADS)

    Horne, Avril C.; Szemis, Joanna M.; Webb, J. Angus; Kaur, Simranjit; Stewardson, Michael J.; Bond, Nick; Nathan, Rory

    2018-03-01

    One important aspect of adaptive management is the clear and transparent documentation of hypotheses, together with the use of predictive models (complete with any assumptions) to test those hypotheses. Documentation of such models can improve the ability to learn from management decisions and supports dialog between stakeholders. A key challenge is how best to represent the existing scientific knowledge to support decision-making. Such challenges are currently emerging in the field of environmental water management in Australia, where managers are required to prioritize the delivery of environmental water on an annual basis, using a transparent and evidence-based decision framework. We argue that the development of models of ecological responses to environmental water use needs to support both the planning and implementation cycles of adaptive management. Here we demonstrate an approach based on the use of Conditional Probability Networks to translate existing ecological knowledge into quantitative models that include temporal dynamics to support adaptive environmental flow management. It equally extends to other applications where knowledge is incomplete, but decisions must still be made.

  14. Ethics, morality, and conflicting interests: how questionable professional integrity in some scientists supports global corporate influence in public health.

    PubMed

    Baur, Xaver; Budnik, Lygia Therese; Ruff, Kathleen; Egilman, David S; Lemen, Richard A; Soskolne, Colin L

    2015-01-01

    Clinical and public health research, education, and medical practice are vulnerable to influence by corporate interests driven by the for-profit motive. Developments over the last 10 years have shown that transparency and self-reporting of corporate ties do not always mitigate bias. In this article, we provide examples of how sound scientific reasoning and evidence-gathering are undermined through compromised scientific enquiry resulting in misleading science, decision-making, and policy intervention. Various medical disciplines provide reference literature essential for informing public, environmental, and occupational health policy. Published literature impacts clinical and laboratory methods, the validity of respective clinical guidelines, and the development and implementation of public health regulations. Said literature is also used in expert testimony related to resolving tort actions on work-related illnesses and environmental risks. We call for increased sensitivity, full transparency, and the implementation of effective ethical and professional praxis rules at all relevant regulatory levels to rout out inappropriate corporate influence in science. This is needed because influencing the integrity of scientists who engage in such activities cannot be depended upon.

  15. Development of transparent microwell arrays for optical monitoring and dissection of microbial communities

    DOE PAGES

    Halsted, Michelle; Wilmoth, Jared L.; Briggs, Paige A.; ...

    2016-09-29

    Microbial communities are incredibly complex systems that dramatically and ubiquitously influence our lives. They help to shape our climate and environment, impact agriculture, drive business, and have a tremendous bearing on healthcare and physical security. Spatial confinement, as well as local variations in physical and chemical properties, affects development and interactions within microbial communities that occupy critical niches in the environment. Recent work has demonstrated the use of silicon based microwell arrays, combined with parylene lift-off techniques, to perform both deterministic and stochastic assembly of microbial communities en masse, enabling the high-throughput screening of microbial communities for their response tomore » growth in confined environments under different conditions. The implementation of a transparent microwell array platform can expand and improve the imaging modalities that can be used to characterize these assembled communities. In this paper, the fabrication and characterization of a next generation transparent microwell array is described. The transparent arrays, comprised of SU-8 patterned on a glass coverslip, retain the ability to use parylene lift-off by integrating a low temperature atomic layer deposition of silicon dioxide into the fabrication process. This silicon dioxide layer prevents adhesion of the parylene material to the patterned SU-8, facilitating dry lift-off, and maintaining the ability to easily assemble microbial communities within the microwells. These transparent microwell arrays can screen numerous community compositions using continuous, high resolution, imaging. Finally, the utility of the design was successfully demonstrated through the stochastic seeding and imaging of green fluorescent protein expressing Escherichia coli using both fluorescence and brightfield microscopies.« less

  16. Price Transparency in the Online Age.

    PubMed

    Kaplan, Jonathan L; Mills, Parker H

    2016-05-01

    Plastic surgeons are sometimes hesitant to provide their pricing information online, due to several concerns. However, if implemented right, price transparency can be used as a lead generation tool that provides consumers with the pricing information they want and gives the physician the consumer's contact information for follow-up. This study took place during the author's first year in private practice in a new city. An interactive price transparency platform (ie, cost estimator) was integrated into his website, allowing consumers to submit a "wishlist" of procedures to check pricing on these procedures of interest. However, the consumer must submit their contact information to receive the desired breakdown of costs that are tailored based on the author's medical fees. During that first year, without any advertising expenditure, the author's website received 412 wishlists from 208 unique consumers. Consumers (17.8%) that submitted a wishlist came in for a consultation and 62% of those booked a procedure. The average value of a booked procedure was over US $4000 and cumulatively, all of the leads from this one lead source in that first year generated over US $92,000 in revenue. When compared with non-price-aware patients, price-aware patients were 41% more likely to book a procedure. Price transparency led to greater efficiency and reduced consultations that ended in "sticker shock." When prudently integrated into a medical practice, price transparency can be a great lead generation source for patients that are (1) paying out of pocket for medically necessary services due to a high-deductible health plan or (2) paying for services not typically covered by insurance, such as cosmetic services.

  17. Broadband tunable electromagnetically induced transparency analogue metamaterials based on graphene in terahertz band

    NASA Astrophysics Data System (ADS)

    Wang, Yue; Leng, Yanbing; Wang, Li; Dong, Lianhe; Liu, Shunrui; Wang, Jun; Sun, Yanjun

    2018-06-01

    Most of the actively controlled electromagnetically induced transparency analogue (EIT-like) metamaterials were implemented with narrowband modulations. In this paper, a broadband tunable EIT-like metamaterial based on graphene in the terahertz band is presented. It consists of a cut wire as the bright resonator and two couples of H-shaped resonators in mirror symmetry as the dark resonators. A broadband tunable property of transmission amplitude is realized by changing the Fermi level of graphene. Furthermore, the geometries of the metamaterial structure are optimized to achieve the ideal curve through the simulation. Such EIT-like metamaterials proposed here are promising candidates for designing active wide-band slow-light devices, wide-band terahertz active filters, and wide-band terahertz modulators.

  18. A flexible telecom satellite repeater based on microwave photonic technologies

    NASA Astrophysics Data System (ADS)

    Sotom, Michel; Benazet, Benoît; Maignan, Michel

    2017-11-01

    Future telecom satellite based on geo-stationary Earth orbit (GEO) will require advanced payloads in Kaband so as to receive, route and re-transmit hundreds of microwave channels over multiple antenna beams. We report on the proof-of-concept demonstration of a analogue repeater making use of microwave photonic technologies for supporting broadband, transparent, and flexible cross-connectivity. It has microwave input and output sections, and features a photonic core for LO distribution, frequency down-conversion, and cross-connection of RF channels. With benefits such as transparency to RF frequency, infinite RF isolation, mass and volume savings, such a microwave photonic cross-connect would compare favourably with microwave implementations, and based on optical MEMS switches could grow up to large port counts.

  19. Vacuum-induced quantum memory in an opto-electromechanical system

    NASA Astrophysics Data System (ADS)

    Qin, Li-Guo; Wang, Zhong-Yang; Wu, Shi-Chao; Gong, Shang-Qing; Ma, Hong-Yang; Jing, Jun

    2018-03-01

    We propose a scheme to implement electrically controlled quantum memory based on vacuum-induced transparency (VIT) in a high-Q tunable cavity, which is capacitively coupled to a mechanically variable capacitor by a charged mechanical cavity mirror as an interface. We analyze the changes of the cavity photons arising from vacuum-induced-Raman process and discuss VIT in an atomic ensemble trapped in the cavity. By slowly adjusting the voltage on the capacitor, the VIT can be adiabatically switched on or off, meanwhile, the transfer between the probe photon state and the atomic spin state can be electrically and adiabatically modulated. Therefore, we demonstrate a vacuum-induced quantum memory by electrically manipulating the mechanical mirror of the cavity based on electromagnetically induced transparency mechanism.

  20. Establishment of Hydrographic Shore Control by Doppler Satellite Techniques.

    DTIC Science & Technology

    1984-06-01

    entered in 8116,h 20. if different tromn Report) 10.SPAccuNTRaY NSdrs AHOacurcystndrd, raslcaio, IS. AEY WRDC (Continue en roer@e side it necessary And...the Defense Mapping Agency, Hydrographic-Topographlc Center (DMA-HTC); the ephemerides are computed and distributed by the DMA-HTC [Ref. 3J. The...all,_ C: En m zz E-4~E- 0 .4 0 = 0 z 4 .4 z 4 c -4 4 1 0j 0 heU 7 60 VIII. ACCURACY STANDARDS AND SPECIFICATIONS A. CURRENT ACCURACY

  1. Nuclear Nonproliferation: Concerns With U.S. Delays in Accepting Foreign Research Reactors’ Spent Fuel

    DTIC Science & Technology

    1994-03-01

    transport or storage plans. The return of some of the spent fuel will also depend on the readiness of dry storage . One expert told us that...enriched uranium fuel (HEU), a material that can be used to make nuclear bombs, in civilian nuclear programs worldwide. Research reactors are of...address the environmental impact of transporting the fuel and storing it in both existing and new storage units, possibly by June 1995. Under the

  2. A Note on the Disturbance Decoupling Problem for Retarded Systems.

    DTIC Science & Technology

    1984-10-01

    disturbance decoupling problem f or linear control system is to design a feedback control law in such a way that the disturbances do not * influence...and in 141 by Pandolfi who analyses the situation in some detail. HeU concludes that for retarded systems one needs an unbounded feedback control law...ult) 6 JP is the control input, d(t) 6 AR is same disturbance, and z(t) e 3k is the output to be regularted. We assume that L is a bounded linear

  3. MBASIC batch processor architectural overview

    NASA Technical Reports Server (NTRS)

    Reynolds, S. M.

    1978-01-01

    The MBASIC (TM) batch processor, a language translator designed to operate in the MBASIC (TM) environment is described. Features include: (1) a CONVERT TO BATCH command, usable from the ready mode; and (2) translation of the users program in stages through several levels of intermediate language and optimization. The processor is to be designed and implemented in both machine-independent and machine-dependent sections. The architecture is planned so that optimization processes are transparent to the rest of the system and need not be included in the first design implementation cycle.

  4. Modelling and simulation of a thermally induced optical transparency in a dual micro-ring resonator

    PubMed Central

    2017-01-01

    This paper introduces the simulation and modelling of a novel dual micro-ring resonator. The geometric configuration of the resonators, and the implementation of a simulated broadband excitation source, results in the realization of optical transparencies in the combined through port output spectrum. The 130 nm silicon on insulator rib fabrication process is adopted for the simulation of the dual-ring configuration. Two titanium nitride heaters are positioned over the coupling regions of the resonators, which can be operated independently, to control the spectral position of the optical transparency. A third heater, centrally located above the dual resonator rings, can be used to red shift the entire spectrum to a required reference resonant wavelength. The free spectral range with no heater currents applied is 4.29 nm. For a simulated heater current of 7 mA (55.7 mW heater power) applied to one of the through coupling heaters, the optical transparency exhibits a red shift of 1.79 nm from the reference resonant wavelength. The ring-to-ring separation of approximately 900 nm means that it can be assumed that there is a zero ring-to-ring coupling field in this model. This novel arrangement has potential applications as a gas mass airflow sensor or a gas species identification sensor. PMID:28791167

  5. Modelling and simulation of a thermally induced optical transparency in a dual micro-ring resonator.

    PubMed

    Lydiate, Joseph

    2017-07-01

    This paper introduces the simulation and modelling of a novel dual micro-ring resonator. The geometric configuration of the resonators, and the implementation of a simulated broadband excitation source, results in the realization of optical transparencies in the combined through port output spectrum. The 130 nm silicon on insulator rib fabrication process is adopted for the simulation of the dual-ring configuration. Two titanium nitride heaters are positioned over the coupling regions of the resonators, which can be operated independently, to control the spectral position of the optical transparency. A third heater, centrally located above the dual resonator rings, can be used to red shift the entire spectrum to a required reference resonant wavelength. The free spectral range with no heater currents applied is 4.29 nm. For a simulated heater current of 7 mA (55.7 mW heater power) applied to one of the through coupling heaters, the optical transparency exhibits a red shift of 1.79 nm from the reference resonant wavelength. The ring-to-ring separation of approximately 900 nm means that it can be assumed that there is a zero ring-to-ring coupling field in this model. This novel arrangement has potential applications as a gas mass airflow sensor or a gas species identification sensor.

  6. Checkpoint-Restart in User Space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CRUISE implements a user-space file system that stores data in main memory and transparently spills over to other storage, like local flash memory or the parallel file system, as needed. CRUISE also exposes file contents fo remote direct memory access, allowing external tools to copy files to the parallel file system in the background with reduced CPU interruption.

  7. Transparency and Accountability: "Implementing a Postsecondary Institution Rating System That Empowers Students While Avoiding Unintended Consequences"

    ERIC Educational Resources Information Center

    Harmon, Tim; Cielinski, Anna

    2014-01-01

    In an economy that increasingly demands postsecondary credentials to access high-paying jobs with the potential for career advancement, students need comprehensive and reliable information to make better college and career choices. This need has prompted a vigorous national dialogue about the best way to provide information on the performance of…

  8. From Equivalence to Transparency of Vocational Diplomas: The Case of France and Germany.

    ERIC Educational Resources Information Center

    Mobus, Martine

    2000-01-01

    The decision to establish equivalencies between vocational training diplomas in France and Germany is a legal act subject to publication in the official gazettes of both countries. The procedure for establishing the equivalence and forms of implementation is defined in arrangements adopted by the committee of Franco-German experts in application…

  9. Optimal Sample Size Determinations for the Heteroscedastic Two One-Sided Tests of Mean Equivalence: Design Schemes and Software Implementations

    ERIC Educational Resources Information Center

    Jan, Show-Li; Shieh, Gwowen

    2017-01-01

    Equivalence assessment is becoming an increasingly important topic in many application areas including behavioral and social sciences research. Although there exist more powerful tests, the two one-sided tests (TOST) procedure is a technically transparent and widely accepted method for establishing statistical equivalence. Alternatively, a direct…

  10. 75 FR 5491 - Privacy Act of 1974: Implementation of Exemptions; Department of Homeland Security/U.S. Customs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-03

    ... nature and the sharing of DHS/ CBP--007 Border Crossing Information system of records information in... system of records also provides notice and transparency to the public as to nature and extent of the... integrity.'' United States v. Flores-Montano, 541 U.S. 149, 153 (2004). Indeed, ``the Government's interest...

  11. How to Present It? On the Rhetoric of an Outstanding Lecturer

    ERIC Educational Resources Information Center

    Movshovitz-Hadar, Nitsa; Hazzan, Orit

    2004-01-01

    This paper analyses a lecture by an excellent teaching award winner professor of mathematics, given to high school mathematics teachers. The analysis is based upon two sources: (i) the lecture plan, as expressed in a series of 29 transparencies, prepared by the lecturer in advance; (ii) the actual implementation of the lecture, as transcribed from…

  12. Warhead Confirmation: A Follow-on to New START

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacArthur, Duncan W.

    This presentation's slides are comprised of the following: Warhead Confirmation: A Follow-on to New START; What May Change?; Generic Arms Reduction Treaty; Challenges; Dismantlement and Warhead Confirmation; Confirmation Approaches; Certification; Information Barriers (IBs); The Fissile Material Transparency Technology Demonstration (FMTTD); More Recent Implementations; The Monitor’s View; Authentication; Authentication Options; Authentication in Phases; and Future Treaties.

  13. 3 CFR 8469 - Proclamation 8469 of December 31, 2009. 40th Anniversary of the National Environmental Policy Act...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... transparency in their implementation of the National Environmental Policy Act. I also encourage every American... Anniversary of the National Environmental Policy Act, 2010 8469 Proclamation 8469 Presidential Documents... Policy Act, 2010By the President of the United States of America A Proclamation Forty years ago, the...

  14. Preliminary Assessment of the Impact on Reactor Vessel dpa Rates Due to Installation of a Proposed Low Enriched Uranium (LEU) Core in the High Flux Isotope Reactor (HFIR)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daily, Charles R.

    2015-10-01

    An assessment of the impact on the High Flux Isotope Reactor (HFIR) reactor vessel (RV) displacements-per-atom (dpa) rates due to operations with the proposed low enriched uranium (LEU) core described by Ilas and Primm has been performed and is presented herein. The analyses documented herein support the conclusion that conversion of HFIR to low-enriched uranium (LEU) core operations using the LEU core design of Ilas and Primm will have no negative impact on HFIR RV dpa rates. Since its inception, HFIR has been operated with highly enriched uranium (HEU) cores. As part of an effort sponsored by the National Nuclearmore » Security Administration (NNSA), conversion to LEU cores is being considered for future HFIR operations. The HFIR LEU configurations analyzed are consistent with the LEU core models used by Ilas and Primm and the HEU balance-of-plant models used by Risner and Blakeman in the latest analyses performed to support the HFIR materials surveillance program. The Risner and Blakeman analyses, as well as the studies documented herein, are the first to apply the hybrid transport methods available in the Automated Variance reduction Generator (ADVANTG) code to HFIR RV dpa rate calculations. These calculations have been performed on the Oak Ridge National Laboratory (ORNL) Institutional Cluster (OIC) with version 1.60 of the Monte Carlo N-Particle 5 (MCNP5) computer code.« less

  15. Reactivity impact of {sup 16}O thermal elastic-scattering nuclear data for some numerical and critical benchmark systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kozier, K. S.; Roubtsov, D.; Plompen, A. J. M.

    2012-07-01

    The thermal neutron-elastic-scattering cross-section data for {sup 16}O used in various modern evaluated-nuclear-data libraries were reviewed and found to be generally too high compared with the best available experimental measurements. Some of the proposed revisions to the ENDF/B-VII.0 {sup 16}O data library and recent results from the TENDL system increase this discrepancy further. The reactivity impact of revising the {sup 16}O data downward to be consistent with the best measurements was tested using the JENDL-3.3 {sup 16}O cross-section values and was found to be very small in MCNP5 simulations of the UO{sub 2} and reactor-recycle MOX-fuel cases of the ANSmore » Doppler-defect numerical benchmark. However, large reactivity differences of up to about 14 mk (1400 pcm) were observed using {sup 16}O data files from several evaluated-nuclear-data libraries in MCNP5 simulations of the Los Alamos National Laboratory HEU heavy-water solution thermal critical experiments, which were performed in the 1950's. The latter result suggests that new measurements using HEU in a heavy-water-moderated critical facility, such as the ZED-2 zero-power reactor at the Chalk River Laboratories, might help to resolve the discrepancy between the {sup 16}O thermal elastic-scattering cross-section values and thereby reduce or better define its uncertainty, although additional assessment work would be needed to confirm this. (authors)« less

  16. Effect of reactor radiation on the thermal conductivity of TREAT fuel

    NASA Astrophysics Data System (ADS)

    Mo, Kun; Miao, Yinbin; Kontogeorgakos, Dimitrios C.; Connaway, Heather M.; Wright, Arthur E.; Yacout, Abdellatif M.

    2017-04-01

    The Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory is resuming operations after more than 20 years in latency in order to produce high-neutron-flux transients for investigating transient-induced behavior of reactor fuels and their interactions with other materials and structures. A parallel program is ongoing to develop a replacement core in which the fuel, historically containing highly-enriched uranium (HEU), is replaced by low-enriched uranium (LEU). Both the HEU and prospective LEU fuels are in the form of UO2 particles dispersed in a graphite matrix, but the LEU fuel will contain a much higher volume of UO2 particles, which may create a larger area of interphase boundaries between the particles and the graphite. This may lead to a higher volume fraction of graphite exposed to the fission fragments escaping from the UO2 particles, and thus may induce a higher volume of fission-fragment damage on the fuel graphite. In this work, we analyzed the reactor-radiation induced thermal conductivity degradation of graphite-based dispersion fuel. A semi-empirical method to model the relative thermal conductivity with reactor radiation was proposed and validated based on the available experimental data. Prediction of thermal conductivity degradation of LEU TREAT fuel during a long-term operation was performed, with a focus on the effect of UO2 particle size on fission-fragment damage. The proposed method can be further adjusted to evaluate the degradation of other properties of graphite-based dispersion fuel.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hummel, Andrew John

    A multitude of critical experiments with highly enriched uranium metal were conducted in the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. These experiments served to evaluate the storage, casting, and handling limits for the Y-12 Plant while also providing data for verification of different calculation methods and associated cross-sections for nuclear criticality safety applications. These included both solid cylinders and annuli of various diameters, interacting cylinders of various diameters, parallelepipeds, and reflected cylinders and annuli. The experiments described here involve a series of delayed critical stacksmore » of bare oralloy HEU annuli and disks. Three of these experiments consist of stacking bare HEU annuli of varying diameters to obtain critical configurations. These annuli have nominal inner and outer diameters (ID/OD) including: 7 inches (") ID – 9" OD, 9" ID – 11" OD, 11" ID – 13" OD, and 13? ID – 15" OD. The nominal heights range from 0.125" to 1.5". The three experiments themselves range from 7" – 13", 7" – 15", and 9" – 15" in diameter, respectively. The fourth experiment ranges from 7" – 11", and along with different annuli, it also includes an 11" disk and several 7" diameter disks. All four delayed critical experiments were configured and evaluated by J. T. Mihalczo, J. J. Lynn, and D. E. McCarty from December of 1962 to February 1963 with additional information in their corresponding logbook.« less

  18. Dynamics of Implementation and Maintenance of Organizational Health Interventions.

    PubMed

    Jalali, Mohammad S; Rahmandad, Hazhir; Bullock, Sally Lawrence; Ammerman, Alice

    2017-08-15

    In this study, we present case studies to explore the dynamics of implementation and maintenance of health interventions. We analyze how specific interventions are built and eroded, how the building and erosion mechanisms are interconnected, and why we can see significantly different erosion rates across otherwise similar organizations. We use multiple comparative obesity prevention case studies to provide empirical information on the mechanisms of interest, and use qualitative systems modeling to integrate our evolving understanding into an internally consistent and transparent theory of the phenomenon. Our preliminary results identify reinforcing feedback mechanisms, including design of organizational processes, motivation of stakeholders, and communication among stakeholders, which influence implementation and maintenance of intervention components. Over time, these feedback mechanisms may drive a wedge between otherwise similar organizations, leading to distinct configurations of implementation and maintenance processes.

  19. [Certified medical centers--A measurable benefit to patients?!].

    PubMed

    Eberlein-Gonska, Maria; Schellong, Sebastian; Baumann, Michael

    2007-01-01

    The establishment of medical centers should meet the high requirements of the healthcare system. They should provide innovative solutions for a number of problems, e.g. the interdisciplinary collaboration of various health departments with due regard to their autonomy. This is reminiscent of the implementation and advancement of a quality management system required by law where a clear idea of how to manage the organizational and procedural structures as an integral part of the management concept implemented is missing. The genuine efforts to implement and advance interdisciplinary medical centers are up against "bogus models" created out of sheer marketing interests. The term "medical center" has so far not been protected under trademark law, leaving patients, relatives or even the referring physicians unsure about how to judge a medical center's actual performance. The same is true of certified centers. Their numbers are growing, but not so the transparency about the amount of measurable, traceable and understandable benefits that a certified center provides to the patient. Therefore clear demands need to be placed on certified centers, especially with regard to the implementation of a concept that provides interdisciplinarity and process-oriented transparent structures and defines quality ratios and quality objectives. This includes providing resources for the continuous collection and evaluation of hard and soft data as well as deriving improvement measures. The three centers of the University Hospital Dresden--the University Cancer Center, the University Vascular Center and the University Pain Center--fulfil this high demand. They have created fundamentals for measurable improvement of patient care and are able to present first results.

  20. Principles of shared decision-making within teams.

    PubMed

    Jacobs, Jeffrey P; Wernovsky, Gil; Cooper, David S; Karl, Tom R

    2015-12-01

    In the domain of paediatric and congenital cardiac care, the stakes are huge. Likewise, the care of these children assembles a group of "A+ personality" individuals from the domains of cardiac surgery, cardiology, anaesthesiology, critical care, and nursing. This results in an environment that has opportunity for both powerful collaboration and powerful conflict. Providers of healthcare should avoid conflict when it has no bearing on outcome, as it is clearly a squandering of individual and collective political capital. Outcomes after cardiac surgery are now being reported transparently and publicly. In the present era of transparency, one may wonder how to balance the following potentially competing demands: quality healthcare, transparency and accountability, and teamwork and shared decision-making. An understanding of transparency and public reporting in the domain of paediatric cardiac surgery facilitates the implementation of a strategy for teamwork and shared decision-making. In January, 2015, the Society of Thoracic Surgeons (STS) began to publicly report outcomes of paediatric and congenital cardiac surgery using the 2014 Society of Thoracic Surgeons Congenital Heart Surgery Database (STS-CHSD) Mortality Risk Model. The 2014 STS-CHSD Mortality Risk Model facilitates description of Operative Mortality adjusted for procedural and patient-level factors. The need for transparency in reporting of outcomes can create pressure on healthcare providers to implement strategies of teamwork and shared decision-making to assure outstanding results. A simple strategy of shared decision-making was described by Tom Karl and was implemented in multiple domains by Jeff Jacobs and David Cooper. In a critical-care environment, it is not unusual for healthcare providers to disagree about strategies of management of patients. When two healthcare providers disagree, each provider can classify the disagreement into three levels: • SDM Level 1 Decision: "We disagree but it really does not matter, so do whatever you desire!" • SDM Level 2 Decision: "We disagree and I believe it matters, but I am OK if you do whatever you desire!!" • SDM Level 3 Decision: "We disagree and I must insist (diplomatically and politely) that we follow the strategy that I am proposing!!!!!!" SDM Level 1 Decisions and SDM Level 2 Decisions typically do not create stress on the team, especially when there is mutual purpose and respect among the members of the team. SDM Level 3 Decisions are the real challenge. Periodically, the healthcare team is faced with such Level 3 Decisions, and teamwork and shared decision-making may be challenged. Teamwork is a learned behaviour, and mentorship is critical to achieve a properly balanced approach. If we agree to leave our egos at the door, then, in the final analysis, the team will benefit and we will set the stage for optimal patient care. In the environment of strong disagreement, true teamwork and shared decision-making are critical to preserve the unity and strength of the multi-disciplinary team and simultaneously provide excellent healthcare.

  1. Validation and uncertainty quantification of detector response functions for a 1″×2″ NaI collimated detector intended for inverse radioisotope source mapping applications

    DOE PAGES

    Nelson, N.; Azmy, Y.; Gardner, R. P.; ...

    2017-08-05

    Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Montemore » Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF rep-resentation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk mea-surements, computed DRF responses tended to significantly underestimate (more than 20%) the sec-ondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the sta-tistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncer-tainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.« less

  2. Validation and uncertainty quantification of detector response functions for a 1″×2″ NaI collimated detector intended for inverse radioisotope source mapping applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, N.; Azmy, Y.; Gardner, R. P.

    Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Montemore » Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF rep-resentation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk mea-surements, computed DRF responses tended to significantly underestimate (more than 20%) the sec-ondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the sta-tistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncer-tainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.« less

  3. Importance of strategic management in the implementation of private medicine retailer programmes: case studies from three districts in Kenya

    PubMed Central

    2010-01-01

    Abstract Background The home-management of malaria strategy seeks to improve prompt and effective anti-malarial drug use through the informal sector, with a potential channel being the Private Medicine Retailers (PMRs). Previous evaluations of PMR programmes focused on their impact on retailer knowledge and practices, with limited evidence about the influence of implementation processes on the impacts at scale. This paper examines how the implementation processes of three PMR programmes in Kenya, each scaled up within a district, contributed to the outcomes observed. These were a Ministry of Health programme in Kwale district; and two programmes supported by non-governmental organizations in collaboration with government in Kisii Central and Bungoma districts. Methods The research methods included 24 focus group discussions with clients and PMRs, 19 in-depth interviews with implementing actors, document review and a diary of events. The data were analysed using the combination of a broad policy analysis framework and more specific scaling up/diffusion of innovations frameworks. Results The Kisii programme, a case study of successful implementation, was underpinned by good relationships between district health managers and a “resource team”, supported by a memorandum of understanding which enabled successful implementation. It had flexible budgetary and decision making processes which were responsive to local contexts, and took account of local socio-economic activities. In contrast, the Kwale programme, which had implementation challenges, was characterised by a complex funding process, with lengthy timelines, that was tied to the government financial management system which constrained implementation Although there was a flexible funding system in Bungoma, a perceived lack of transparency in fund management, inadequate management of inter-organisational relationships, and inability to adapt and respond to changing circumstances led to implementation difficulties. Conclusions For effective scaling up of PMR programmes, the provision of technical support and adequate resources are vital, but not sufficient on their own. An active strategy to manage relationships between implementing actors through effective communication mechanisms is essential. Successful outcomes may be realised if a strong and transparent management system, including management of financial resources, is put in place. This study provides evidence of the value of assessing implementation processes as part of impact evaluation for public health programmes. PMID:20594373

  4. Importance of strategic management in the implementation of private medicine retailer programmes: case studies from three districts in Kenya.

    PubMed

    Abuya, Timothy; Amin, Abdinasir; Molyneux, Sassy; Akhwale, Willis; Marsh, Vicki; Gilson, Lucy

    2010-07-02

    The home-management of malaria strategy seeks to improve prompt and effective anti-malarial drug use through the informal sector, with a potential channel being the Private Medicine Retailers (PMRs). Previous evaluations of PMR programmes focused on their impact on retailer knowledge and practices, with limited evidence about the influence of implementation processes on the impacts at scale. This paper examines how the implementation processes of three PMR programmes in Kenya, each scaled up within a district, contributed to the outcomes observed. These were a Ministry of Health programme in Kwale district; and two programmes supported by non-governmental organizations in collaboration with government in Kisii Central and Bungoma districts. The research methods included 24 focus group discussions with clients and PMRs, 19 in-depth interviews with implementing actors, document review and a diary of events. The data were analysed using the combination of a broad policy analysis framework and more specific scaling up/diffusion of innovations frameworks. The Kisii programme, a case study of successful implementation, was underpinned by good relationships between district health managers and a "resource team", supported by a memorandum of understanding which enabled successful implementation. It had flexible budgetary and decision making processes which were responsive to local contexts, and took account of local socio-economic activities. In contrast, the Kwale programme, which had implementation challenges, was characterised by a complex funding process, with lengthy timelines, that was tied to the government financial management system which constrained implementation Although there was a flexible funding system in Bungoma, a perceived lack of transparency in fund management, inadequate management of inter-organisational relationships, and inability to adapt and respond to changing circumstances led to implementation difficulties. For effective scaling up of PMR programmes, the provision of technical support and adequate resources are vital, but not sufficient on their own. An active strategy to manage relationships between implementing actors through effective communication mechanisms is essential. Successful outcomes may be realised if a strong and transparent management system, including management of financial resources, is put in place. This study provides evidence of the value of assessing implementation processes as part of impact evaluation for public health programmes.

  5. Informing Education Policy in Afghanistan: Using Design of Experiments and Data Envelopment Analysis to Provide Transparency in Complex Simulation

    ERIC Educational Resources Information Center

    Marlin, Benjamin

    2013-01-01

    Education planning provides the policy maker and the decision maker a logical framework in which to develop and implement education policy. At the international level, education planning is often confounded by both internal and external complexities, making the development of education policy difficult. This research presents a discrete event…

  6. Quantitative Analysis in the General Chemistry Laboratory: Training Students to Analyze Individual Results in the Context of Collective Data

    ERIC Educational Resources Information Center

    Ling, Chris D.; Bridgeman, Adam J.

    2011-01-01

    Titration experiments are ideal for generating large data sets for use in quantitative-analysis activities that are meaningful and transparent to general chemistry students. We report the successful implementation of a sophisticated quantitative exercise in which the students identify a series of unknown acids by determining their molar masses…

  7. Show Me What I'm Looking for: A Trustee's Guide to Reviewing the New IRS Form 990

    ERIC Educational Resources Information Center

    Hyatt, Thomas K.

    2009-01-01

    Much has been made of the Internal Revenue Service's introduction of the completely revised Form 990 last year. The Internal Revenue Service's primary goals in implementing the revised form are to increase transparency and promote accountability and compliance. Indeed, the information required in the new form will offer the clearest picture to…

  8. What Impact Will NCLB Waivers Have on the Consistency, Complexity and Transparency of State Accountability Systems?

    ERIC Educational Resources Information Center

    Riddle, Wayne

    2012-01-01

    In September 2011, the Obama Administration initiated a program to grant states waivers of several significant requirements of the Elementary and Secondary Education Act (ESEA), as amended by the No Child Left Behind Act (NCLB). This initiative grew out of a concern that "in its implementation, No Child Left Behind had some serious flaws that…

  9. Local network interconnection through a satellite point-to-multipoint link. Ph.D. Thesis - Ecole Nationale Superieure des Telecommunications, 6 Jul. 1985

    NASA Technical Reports Server (NTRS)

    Duarte, O. Muniz Bandeira

    1986-01-01

    Four architectures to implement a point to multipoint satellite link protocol for communication services offered by the Telecom 1 satellite network are presented. A safe communication service with error correction and flow control facilities is described. It is shown that a time transparent communication system combines simplicity and cost advantages.

  10. A Body of Work Standard-Setting Method with Construct Maps

    ERIC Educational Resources Information Center

    Wyse, Adam E.; Bunch, Michael B.; Deville, Craig; Viger, Steven G.

    2014-01-01

    This article describes a novel variation of the Body of Work method that uses construct maps to overcome problems of transparency, rater inconsistency, and scores gaps commonly occurring with the Body of Work method. The Body of Work method with construct maps was implemented to set cut-scores for two separate K-12 assessment programs in a large…

  11. Using Visible Speech to Train Perception and Production of Speech for Individuals with Hearing Loss.

    ERIC Educational Resources Information Center

    Massaro, Dominic W.; Light, Joanna

    2004-01-01

    The main goal of this study was to implement a computer-animated talking head, Baldi, as a language tutor for speech perception and production for individuals with hearing loss. Baldi can speak slowly; illustrate articulation by making the skin transparent to reveal the tongue, teeth, and palate; and show supplementary articulatory features, such…

  12. Recurrent network dynamics reconciles visual motion segmentation and integration.

    PubMed

    Medathati, N V Kartheek; Rankin, James; Meso, Andrew I; Kornprobst, Pierre; Masson, Guillaume S

    2017-09-12

    In sensory systems, a range of computational rules are presumed to be implemented by neuronal subpopulations with different tuning functions. For instance, in primate cortical area MT, different classes of direction-selective cells have been identified and related either to motion integration, segmentation or transparency. Still, how such different tuning properties are constructed is unclear. The dominant theoretical viewpoint based on a linear-nonlinear feed-forward cascade does not account for their complex temporal dynamics and their versatility when facing different input statistics. Here, we demonstrate that a recurrent network model of visual motion processing can reconcile these different properties. Using a ring network, we show how excitatory and inhibitory interactions can implement different computational rules such as vector averaging, winner-take-all or superposition. The model also captures ordered temporal transitions between these behaviors. In particular, depending on the inhibition regime the network can switch from motion integration to segmentation, thus being able to compute either a single pattern motion or to superpose multiple inputs as in motion transparency. We thus demonstrate that recurrent architectures can adaptively give rise to different cortical computational regimes depending upon the input statistics, from sensory flow integration to segmentation.

  13. Price transparency for MRIs increased use of less costly providers and triggered provider competition.

    PubMed

    Wu, Sze-jung; Sylwestrzak, Gosia; Shah, Christiane; DeVries, Andrea

    2014-08-01

    To encourage patients to select high-value providers, an insurer-initiated price transparency program that focused on elective advanced imaging procedures was implemented. Patients having at least one outpatient magnetic resonance imaging (MRI) scan in 2010 or 2012 were divided according to their membership in commercial health plans participating in the program (the intervention group) or in nonparticipating commercial health plans (the reference group) in similar US geographic regions. Patients in the intervention group were informed of price differences among available MRI facilities and given the option of selecting different providers. For those patients, the program resulted in a $220 cost reduction (18.7 percent) per test and a decrease in use of hospital-based facilities from 53 percent in 2010 to 45 percent in 2012. Price variation between hospital and nonhospital facilities for the intervention group was reduced by 30 percent after implementation. Nonparticipating members residing in intervention areas also observed price reductions, which indicates increased price competition among providers. The program significantly reduced imaging costs. This suggests that patients select lower-price facilities when informed about available alternatives. Project HOPE—The People-to-People Health Foundation, Inc.

  14. Compressed Video Segmentation

    DTIC Science & Technology

    1996-09-01

    Fk+gl1mGnCop![ qVa +HeU95.!:r%I>0&CFS+I,:Y45&C47%,:d&C$+&6%=( 1 (3`F-FS+/`+9597@s%8.1F:Q.18.1FS+I9V>AFG+He.: 45,(395`/=.R>t...Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per...penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1 . REPORT DATE SEP 1996

  15. A Biographical Approach to Chinese Political Analysis

    DTIC Science & Technology

    1975-10-01

    Liu Po-ch’eng Chang Kuo -t ’ao Ch’en I Su Yll Lin Piao Nieh Jung -chen Sources: William Whitson, "The Field Army in Chinese Communist Military...since 1954 Founders 1, 2, 3, 5, 6 Ho Lung 12, 13, 14, 15, HeU Haiang-ch’ien 16, 18, 60 (in Liu Po-ch ’eng Szechwan), 61, 62 Chang Kuo -t’ ao 20...66, 67. 68 Nieh Jung -chen Sources: William Whitson, "The Field Army in Chinese Communist Military Politics," The China Quarterly, No, 37, Januar y

  16. Uranium Enrichment Safeguards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demuth, Scott F.; Trahan, Alexis Chanel

    2017-06-26

    DIV of facility layout, material flows, and other information provided in the DIQ. Material accountancy through an annual PIV and a number of interim inventory verifications, including UF6 cylinder identification and counting, NDA of cylinders, and DA on a sample collection of UF6. Application of C/S technologies utilizing seals and tamper-indicating devices (TIDs) on cylinders, containers, storage rooms, and IAEA instrumentation to provide continuity of knowledge between inspection. Verification of the absence of undeclared material and operations, especially HEU production, through SNRIs, LFUA of cascade halls, and environmental swipe sampling

  17. Deterrence and Engagement: U.S. and North Korean Interactions over Nuclear Weapons since the End of the Cold War

    DTIC Science & Technology

    2008-12-01

    Self-help,” International Security 19, no. 3 (Winter 1994-1995). 86 Bruce Auster and Kevin Whitelaw, “Upping the ante for Kim Jong Il: Pentagon Plan...and Kevin O’Neil, Solving the North Korean Nuclear Puzzle (Washington, D.C.: Institute for Science and International Security Press, 2002), 57-82...Minister Kim Gye Kwan “angrily denied that the DPRK had an HEU program. He dismissed my statement, claiming it was a fabrication.”234 And then, in the

  18. FMDP reactor alternative summary report. Volume 1 - existing LWR alternative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greene, S.R.; Bevard, B.B.

    1996-10-07

    Significant quantities of weapons-usable fissile materials [primarily plutonium and highly enriched uranium (HEU)] are becoming surplus to national defense needs in both the United States and Russia. These stocks of fissile materials pose significant dangers to national and international security. The dangers exist not only in the potential proliferation of nuclear weapons but also in the potential for environmental, safety, and health (ES&H) consequences if surplus fissile materials are not properly managed. This document summarizes the results of analysis concerned with existing light water reactor plutonium disposition alternatives.

  19. Policy and Technical Issues Facing a Fissile Material (Cutoff) Treaty

    DOE PAGES

    von Hippel, Frank; Mian, Zia

    2015-05-18

    We report the largest obstacle to creating nuclear weapons, starting with the ones that destroyed Hiroshima and Nagasaki, has been to make sufficient quantities of fissile materials – highly enriched uranium (HEU) and plutonium – to sustain an explosive fission chain reaction.1 Recognition of this fact has, for more than fifty years, underpinned both the support for and the opposition to adoption of an international treaty banning at a minimum the production of more fissile materials for nuclear weapons, commonly referred to as a fissile material cutoff treaty (FMCT).

  20. Oxide semiconductors for organic opto-electronic devices

    NASA Astrophysics Data System (ADS)

    Sigdel, Ajaya K.

    In this dissertation, I have introduced various concepts on the modulations of various surface, interface and bulk opto-electronic properties of ZnO based semiconductor for charge transport, charge selectivity and optimal device performance. I have categorized transparent semiconductors into two sub groups depending upon their role in a device. Electrodes, usually 200 to 500 nm thick, optimized for good transparency and transporting the charges to the external circuit. Here, the electrical conductivity in parallel direction to thin film, i.e bulk conductivity is important. And contacts, usually 5 to 50 nm thick, are optimized in case of solar cells for providing charge selectivity and asymmetry to manipulate the built in field inside the device for charge separation and collection. Whereas in Organic LEDs (OLEDs), contacts provide optimum energy level alignment at organic oxide interface for improved charge injections. For an optimal solar cell performance, transparent electrodes are designed with maximum transparency in the region of interest to maximize the light to pass through to the absorber layer for photo-generation, plus they are designed for minimum sheet resistance for efficient charge collection and transport. As such there is need for material with high conductivity and transparency. Doping ZnO with some common elements such as B, Al, Ga, In, Ge, Si, and F result in n-type doping with increase in carriers resulting in high conductivity electrode, with better or comparable opto-electronic properties compared to current industry-standard indium tin oxide (ITO). Furthermore, improvement in mobility due to improvement on crystallographic structure also provide alternative path for high conductivity ZnO TCOs. Implementing these two aspects, various studies were done on gallium doped zinc oxide (GZO) transparent electrode, a very promising indium free electrode. The dynamics of the superimposed RF and DC power sputtering was utilized to improve the microstructure during the thin films growth, resulting in GZO electrode with conductivity greater than 4000 S/cm and transparency greater than ˜ 90%. Similarly, various studies on research and development of Indium Zinc Tin Oxide and Indium Zinc Oxide thin films which can be applied to flexible substrates for next generation solar cells application is presented. In these new TCO systems, understanding the role of crystallographic structure ranging from poly-crystalline to amorphous phase and the influence on the charge transport and optical transparency as well as important surface passivation and surface charge transport properties. Implementation of these electrode based on ZnO on opto-electronics devices such as OLED and OPV is complicated due to chemical interaction over time with the organic layer or with ambient. The problem of inefficient charge collection/injection due to poor understanding of interface and/or bulk property of oxide electrode exists at several oxide-organic interfaces. The surface conductivity, the work function, the formation of dipoles and the band-bending at the interfacial sites can positively or negatively impact the device performance. Detailed characterization of the surface composition both before and after various chemicals treatment of various oxide electrode can therefore provide insight into optimization of device performance. Some of the work related to controlling the interfacial chemistry associated with charge transport of transparent electrodes are discussed. Thus, the role of various pre-treatment on poly-crystalline GZO electrode and amorphous indium zinc oxide (IZO) electrode is compared and contrasted. From the study, we have found that removal of defects and self passivating defects caused by accumulation of hydroxides in the surface of both poly-crystalline GZO and amorphous IZO, are critical for improving the surface conductivity and charge transport. Further insight on how these insulating and self-passivating defects cause charge accumulation and recombination in an device is discussed. (Abstract shortened by UMI.)

  1. Procedures and methods of benefit assessments for medicines in Germany.

    PubMed

    Bekkering, Geertruida E; Kleijnen, Jos

    2008-11-01

    The Federal Joint Committee (FJC; Gemeinsamer Bundesausschuss, G-BA) defines the health-care elements that are to be reimbursed by sickness funds. To define a directive, the FJC can commission benefit assessments, which provide an overview of the scientific evidence regarding the efficacy and benefits of an intervention. This paper describes the operational implementation of the legal requirements with regard to the benefit assessments of medicines. Such benefit assessments are sometimes referred to as "isolated benefit assessments," to distinguish them from benefit assessments as part of a full economic evaluation.The FJC has the freedom to commission these assessments from any agency; however, to date the majority have commissioned the Institute for Quality and Efficiency in Health Care (IQWiG). Nevertheless, the content of this paper applies integrally to any institute commissioned for such assessments. In this report, 'the institute' is used when the text refers to any of these institutes.The legal framework for benefit assessments is laid out in the German Social Code Book version V ( http://www.sozialgesetzbuch.de ), Sects. 35b ( section 1), 139a ( section 4-6) and Sect. 139b ( section 3). It is specified that: The institute must guarantee high transparency. The institute must provide appropriate participation of relevant parties for the commission-related development of assessments, and opportunity for comment on all important segments of the assessment procedure. The institute has to report on the progress and results of the work at regular intervals. The institute is held to giving the commission to external experts. Based on the legal framework, the institute must guarantee a high procedural transparency. Transparency of the whole process should be achieved, which is evidenced by clear reporting of procedures and criteria in all phases undertaken in the benefit assessment. The most important means of enhancing transparency are: 1. To implement a scoping process to support the development of the research question. 2. To separate the work of the external experts performing the evidence assessment from that of the institute formulating recommendations. Therefore, the preliminary report as produced by external experts needs to be public, and published separately from any subsequent amendments or (draft-)reports made by the institute, which includes the institute's recommendations. 3. To implement open peer review by publishing both the comments of the reviewers and their names. Based on the legal framework, the institute must provide for adequate participation of relevant parties. These include organisations representing the interests of patients; experts of medical, pharmaceutical and health economic science and practice; the professional organisations of pharmacists and pharmaceutical companies; and experts on alternative therapies. Patients and health care professionals bring in new insights with respect to research priorities, treatment and outcomes.The relevant parties should be identified and contacted whenever the global scope of the assessment has been drafted. Subsequently, the relevant parties should be involved in defining the research question, developing the protocol and commenting on the preliminary report. To implement the involvement of relevant parties in defining the research question a scoping process is suggested. For the other phases, written comments followed by an oral discussion should be used. Finally, the relevant parties should have the right to appeal the final decision on judicial grounds. None of these steps mean that the institute would lose any part of its scientific independence.From the relevant sections of the legal framework with respect to the assessment methods, it can be concluded that: 1. The institute must ensure that the assessment is made in accordance with internationally recognised standards of evidence-based medicine (EBM). 2. The assessment is conducted in comparison with other medicines and treatment forms under consideration of the additional therapeutic benefit for the patients. 3. The minimum criteria for assessing patient benefit are improvements in the state of health, shortening the duration of illness, extension of the duration of life, reduction of side effects and improvements in quality of life. EBM refers to the application of the best available evidence to answer a research question, which can inform questions about the care of patients. The optimal design, even for effectiveness questions, is not always the randomised, controlled trial (RCT) but depends on the research question and the outcomes of interest. To increase transparency for each question, the levels of evidence examined should be made explicit. There is no empirical evidence to support the use of cutoff points with respect to the number of studies before making recommendations. To get the best available evidence for the research question(s), all relevant evidence should be considered for each question, and the best available evidence should be used to answer the question. Separate levels of evidence may have to be used for each outcome.There are many ways in which bias can be introduced in systematic reviews. Some types of bias can be prevented, other types can only be reported and, for some, the influence of the bias can be investigated. Reviews must show that potential sources of bias have been dealt with adequately.Methods used by other agencies that perform benefit assessments are useful to interpret the term 'international standards' to which the institute must comply. The National Institute for Health and Clinical Excellence (NICE) is a good example in this respect. NICE shows that it is possible to have transparent procedures for benefit assessments but that this requires detailed documentation. NICE has implemented an open procedure with respect to the comments of reviewers, which makes the procedure transparent. Although the Institute for Quality and Efficiency in Health Care (IQWiG) in Germany invites comments on their protocol and preliminary report by posting them on their website, and comments are made public, the individual comments are not evaluated openly, and therefore it remains uncertain whether or not they lead to changes in the reports. The participation of relevant parties in the assessment process as implemented by NICE guarantees a process that is transparent to all relevant parties.Transparency of the whole process is assured by clear reporting of procedures and criteria in all phases undertaken in the benefit assessment. In a scoping process, a draft scope is commented on first in writing and subsequently in the form of a scoping workshop. In this way, all relevant aspects can be heard and included in the final scope. The protocol is then developed, followed by evidence assessment. The methods used should be completely reported to show readers that the assessment has been performed with scientific rigour and that bias has been prevented where possible. All relevant parties should have the opportunity to comment on the draft protocol and the draft preliminary report. Each comment should be evaluated as to whether or not it will lead to changes, and both the comments and the evaluation should be made public to ensure transparency of this process. The same procedure should be used for the peer-review phase. Based on the final report of the evidence assessment, the institute forms recommendations and the FJC appraises the evidence.During the writing of the final report, a separation between the evidence assessment and the evidence-appraisal phase should be implemented. Ideally, this separation should be legally enforced to prevent any confusion about conflict of interests.Such a process guarantees a feasible combination of the legal requirements for transparency and involvement of relevant parties with international standards of EBM to ensure that the benefit assessments of medicines in Germany are performed according to the highest standards.

  2. [Procedures and methods of benefit assessments for medicines in Germany].

    PubMed

    Bekkering, G E; Kleijnen, J

    2008-12-01

    The Federal Joint Committee (FJC; Gemeinsamer Bundesausschuss, G-BA) defines the health-care elements that are to be reimbursed by sickness funds. To define a directive, the FJC can commission benefit assessments, which provide an overview of the scientific evidence regarding the efficacy and benefits of an intervention. This paper describes the operational implementation of the legal requirements with regard to the benefit assessments of medicines. Such benefit assessments are sometimes referred to as "isolated benefit assessments," to distinguish them from benefit assessments as part of a full economic evaluation. The FJC has the freedom to commission these assessments from any agency; however, to date the majority have commissioned the Institute for Quality and Efficiency in Health Care (IQWiG). Nevertheless, the content of this paper applies integrally to any institute commissioned for such assessments. In this report, "the institute"' is used when the text refers to any of these institutes. The legal framework for benefit assessments is laid out in the German Social Code Book version V (http://www. sozialgesetzbuch.de), Sects. 35b ( section sign 1), 139a ( section sign 4-6) and Sect. 139b ( section sign 3). It is specified that: The institute must guarantee high transparency. The institute must provide appropriate participation of relevant parties for the commission-related development of assessments, and opportunity for comment on all important segments of the assessment procedure. The institute has to report on the progress and results of the work at regular intervals. The institute is held to giving the commission to external experts. Based on the legal framework, the institute must guarantee a high procedural transparency. Transparency of the whole process should be achieved, which is evidenced by clear reporting of procedures and criteria in all phases undertaken in the benefit assessment. The most important means of enhancing transparency are: 1. To implement a scoping process to support the development of the research question. 2. To separate the work of the external experts performing the evidence assessment from that of the institute formulating recommendations. Therefore, the preliminary report as produced by external experts needs to be public, and published separately from any subsequent amendments or (draft-)reports made by the institute, which includes the institute's recommendations. 3. To implement open peer review by publishing both the comments of the reviewers and their names. Based on the legal framework, the institute must provide for adequate participation of relevant parties. These include organisations representing the interests of patients; experts of medical, pharmaceutical and health economic science and practice; the professional organisations of pharmacists and pharmaceutical companies; and experts on alternative therapies. Patients and health care professionals bring in new insights with respect to research priorities, treatment and outcomes. The relevant parties should be identified and contacted whenever the global scope of the assessment has been drafted. Subsequently, the relevant parties should be involved in defining the research question, developing the protocol and commenting on the preliminary report. To implement the involvement of relevant parties in defining the research question a scoping process is suggested. For the other phases, written comments followed by an oral discussion should be used. Finally, the relevant parties should have the right to appeal the final decision on judicial grounds. None of these steps mean that the institute would lose any part of its scientific independence. From the relevant sections of the legal framework with respect to the assessment methods, it can be concluded that: 1. The institute must ensure that the assessment is made in accordance with internationally recognised standards of evidence-based medicine (EBM). 2. The assessment is conducted in comparison with other medicines and treatment forms under consideration of the additional therapeutic benefit for the patients. 3. The minimum criteria for assessing patient benefit are improvements in the state of health, shortening the duration of illness, extension of the duration of life, reduction of side effects and improvements in quality of life. EBM refers to the application of the best available evidence to answer a research question, which can inform questions about the care of patients. The optimal design, even for effectiveness questions, is not always the randomised, controlled trial (RCT) but depends on the research question and the outcomes of interest. To increase transparency for each question, the levels of evidence examined should be made explicit. There is no empirical evidence to support the use of cutoff points with respect to the number of studies before making recommendations. To get the best available evidence for the research question(s), all relevant evidence should be considered for each question, and the best available evidence should be used to answer the question. Separate levels of evidence may have to be used for each outcome. There are many ways in which bias can be introduced in systematic reviews. Some types of bias can be prevented, other types can only be reported and, for some, the influence of the bias can be investigated. Reviews must show that potential sources of bias have been dealt with adequately. Methods used by other agencies that perform benefit assessments are useful to interpret the term 'international standards' to which the institute must comply. The National Institute for Health and Clinical Excellence (NICE) is a good example in this respect. NICE shows that it is possible to have transparent procedures for benefit assessments but that this requires detailed documentation. NICE has implemented an open procedure with respect to the comments of reviewers, which makes the procedure transparent. Although the Institute for Quality and Efficiency in Health Care (IQWiG) in Germany invites comments on their protocol and preliminary report by posting them on their website, and comments are made public, the individual comments are not evaluated openly, and therefore it remains uncertain whether or not they lead to changes in the reports. The participation of relevant parties in the assessment process as implemented by NICE guarantees a process that is transparent to all relevant parties. Transparency of the whole process is assured by clear reporting of procedures and criteria in all phases undertaken in the benefit assessment. In a scoping process, a draft scope is commented on first in writing and subsequently in the form of a scoping workshop. In this way, all relevant aspects can be heard and included in the final scope. The protocol is then developed, followed by evidence assessment. The methods used should be completely reported to show readers that the assessment has been performed with scientific rigour and that bias has been prevented where possible. All relevant parties should have the opportunity to comment on the draft protocol and the draft preliminary report. Each comment should be evaluated as to whether or not it will lead to changes, and both the comments and the evaluation should be made public to ensure transparency of this process. The same procedure should be used for the peer-review phase. Based on the final report of the evidence assessment, the institute forms recommendations and the FJC appraises the evidence. During the writing of the final report, a separation between the evidence assessment and the evidence appraisal phase should be implemented. Ideally, this separation should be legally enforced to prevent any confusion about conflict of interests. Such a process guarantees a feasible combination of the legal requirements for transparency and involvement of relevant parties with international standards of EBM to ensure that the benefit assessments of medicines in Germany are performed according to the highest standards.

  3. Bottom-up priority setting revised. A second evaluation of an institutional intervention in a Swedish health care organisation.

    PubMed

    Waldau, Susanne

    2015-09-01

    Transparent priority setting in health care based on specific ethical principles is requested by the Swedish Parliament since 1997. Implementation has been limited. In this case, transparent priority setting was performed for a second time round and engaged an entire health care organisation. Objectives were to refine a bottom-up priority setting process, reach a political decision on service limits to make reallocation towards higher prioritised services possible, and raise systems knowledge. An action research approach was chosen. The national model for priority setting was used with addition of dimensions costs, volumes, gender distribution and feasibility. The intervention included a three step process and specific procedures for each step which were created, revised and evaluated regarding factual and functional aspects. Evaluations methods included analyses of documents, recordings and surveys. Vertical and horizontal priority setting occurred and resources were reallocated. Participants' attitudes remained positive, however less so than in the first priority setting round. Identifying low-priority services was perceived difficult, causing resentment and strategic behaviour. The horizontal stage served to raise quality of the knowledge base, level out differences in ranking of services and raise systems knowledge. Existing health care management systems do not meet institutional requirements for transparent priority setting. Introducing transparent priority setting constitutes a complex institutional reform, which needs to be driven by management/administration. Strong managerial commitment is required. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halsted, Michelle; Wilmoth, Jared L.; Briggs, Paige A.

    Microbial communities are incredibly complex systems that dramatically and ubiquitously influence our lives. They help to shape our climate and environment, impact agriculture, drive business, and have a tremendous bearing on healthcare and physical security. Spatial confinement, as well as local variations in physical and chemical properties, affects development and interactions within microbial communities that occupy critical niches in the environment. Recent work has demonstrated the use of silicon based microwell arrays, combined with parylene lift-off techniques, to perform both deterministic and stochastic assembly of microbial communities en masse, enabling the high-throughput screening of microbial communities for their response tomore » growth in confined environments under different conditions. The implementation of a transparent microwell array platform can expand and improve the imaging modalities that can be used to characterize these assembled communities. In this paper, the fabrication and characterization of a next generation transparent microwell array is described. The transparent arrays, comprised of SU-8 patterned on a glass coverslip, retain the ability to use parylene lift-off by integrating a low temperature atomic layer deposition of silicon dioxide into the fabrication process. This silicon dioxide layer prevents adhesion of the parylene material to the patterned SU-8, facilitating dry lift-off, and maintaining the ability to easily assemble microbial communities within the microwells. These transparent microwell arrays can screen numerous community compositions using continuous, high resolution, imaging. Finally, the utility of the design was successfully demonstrated through the stochastic seeding and imaging of green fluorescent protein expressing Escherichia coli using both fluorescence and brightfield microscopies.« less

  5. Quality management, a directive approach to patient safety.

    PubMed

    Ayuso-Murillo, Diego; de Andrés-Gimeno, Begoña; Noriega-Matanza, Concha; López-Suárez, Rafael Jesús; Herrera-Peco, Ivan

    Nowadays the implementation of effective quality management systems and external evaluation in healthcare is a necessity to ensure not only transparency in activities related to health but also access to health and patient safety. The key to correctly implementing a quality management system is support from the managers of health facilities, since it is managers who design and communicate to health professionals the strategies of action involved in quality management systems. This article focuses on nursing managers' approach to quality management through the implementation of cycles of continuous improvement, participation of improvement groups, monitoring systems and external evaluation quality models (EFQM, ISO). The implementation of a quality management system will enable preventable adverse effects to be minimized or eliminated, and promote patient safety and safe practice by health professionals. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  6. Dynamics of Implementation and Maintenance of Organizational Health Interventions

    PubMed Central

    Rahmandad, Hazhir; Bullock, Sally Lawrence; Ammerman, Alice

    2017-01-01

    In this study, we present case studies to explore the dynamics of implementation and maintenance of health interventions. We analyze how specific interventions are built and eroded, how the building and erosion mechanisms are interconnected, and why we can see significantly different erosion rates across otherwise similar organizations. We use multiple comparative obesity prevention case studies to provide empirical information on the mechanisms of interest, and use qualitative systems modeling to integrate our evolving understanding into an internally consistent and transparent theory of the phenomenon. Our preliminary results identify reinforcing feedback mechanisms, including design of organizational processes, motivation of stakeholders, and communication among stakeholders, which influence implementation and maintenance of intervention components. Over time, these feedback mechanisms may drive a wedge between otherwise similar organizations, leading to distinct configurations of implementation and maintenance processes. PMID:28809807

  7. The Design of a Transparent Vertical Multizone Furnace: Application to Thermal Field Tuning and Crystal Growth

    NASA Technical Reports Server (NTRS)

    Duvual, Walter M. B.; Batur, Celal; Bennett, Robert J.

    1998-01-01

    We present an innovative design of a vertical transparent multizone furnace which can operate in the temperature range of 25 C to 750 C and deliver thermal gradients of 2 C/cm to 45 C/cm for the commercial applications to crystal growth. The operation of the eight zone furnace is based on a self-tuning temperature control system with a DC power supply for optimal thermal stability. We show that the desired thermal profile over the entire length of the furnace consists of a functional combination of the fundamental thermal profiles for each individual zone obtained by setting the set-point temperature for that zone. The self-tuning system accounts for the zone to zone thermal interactions. The control system operates such that the thermal profile is maintained under thermal load, thus boundary conditions on crystal growth ampoules can be predetermined prior to crystal growth. Temperature profiles for the growth of crystals via directional solidification, vapor transport techniques, and multiple gradient applications are shown to be easily implemented. The unique feature of its transparency and ease of programming thermal profiles make the furnace useful in scientific and commercial applications for determining the optimized process parameters for crystal growth.

  8. Self-visualization of transparent microscopic objects in optical glasses under the conditions of the thermal self-action of an illuminating laser beam

    NASA Astrophysics Data System (ADS)

    Bubis, E. L.; Palashov, O. V.; Kuz'min, I. V.; Snetkov, I. L.; Gusev, S. A.

    2017-03-01

    We demonstrate the process of adaptive self-visualization of small-scale transparent objects and structures in weakly absorbing optical glasses (a glass plate made of K8 and an NS-1 neutral density filter) placed in the Fourier plane of the optical system under the conditions of thermal self-action of the illuminating laser beam. The process is based on the ideology of the classical Zernike phase contrast method. The process is implemented at the level of power of radiation of the illuminated object varying from several milliwatts to tens of watts in the visible and IR spectral ranges. The conducted experiments indicate that the visualization takes place in all glasses and optical elements fabricated from them at an appropriate level of the radiation power.

  9. Multiplexed image storage by electromagnetically induced transparency in a solid

    NASA Astrophysics Data System (ADS)

    Heinze, G.; Rentzsch, N.; Halfmann, T.

    2012-11-01

    We report on frequency- and angle-multiplexed image storage by electromagnetically induced transparency (EIT) in a Pr3+:Y2SiO5 crystal. Frequency multiplexing by EIT relies on simultaneous storage of light pulses in atomic coherences, driven in different frequency ensembles of the inhomogeneously broadened solid medium. Angular multiplexing by EIT relies on phase matching of the driving laser beams, which permits simultaneous storage of light pulses propagating under different angles into the crystal. We apply the multiplexing techniques to increase the storage capacity of the EIT-driven optical memory, in particular to implement multiplexed storage of larger two-dimensional amounts of data (images). We demonstrate selective storage and readout of images by frequency-multiplexed EIT and angular-multiplexed EIT, as well as the potential to combine both multiplexing approaches towards further enhanced storage capacities.

  10. Mind the gap: implementation challenges break the link between HIV/AIDS research and practice.

    PubMed

    MacCarthy, Sarah; Reisner, Sari; Hoffmann, Michael; Perez-Brumer, Amaya; Silva-Santisteban, Alfonso; Nunn, Amy; Bastos, Leonardo; Vasconcellos, Mauricio Teixeira Leite de; Kerr, Ligia; Bastos, Francisco Inácio; Dourado, Inês

    2016-11-03

    Sampling strategies such as respondent-driven sampling (RDS) and time-location sampling (TLS) offer unique opportunities to access key populations such as men who have sex with men (MSM) and transgender women. Limited work has assessed implementation challenges of these methods. Overcoming implementation challenges can improve research quality and increase uptake of HIV services among key populations. Drawing from studies using RDS in Brazil and TLS in Peru, we summarize challenges encountered in the field and potential strategies to address them. In Brazil, study site selection, cash incentives, and seed selection challenged RDS implementation with MSM. In Peru, expansive geography, safety concerns, and time required for study participation complicated TLS implementation with MSM and transgender women. Formative research, meaningful participation of key populations across stages of research, and transparency in study design are needed to link HIV/AIDS research and practice. Addressing implementation challenges can close gaps in accessing services among those most burdened by the epidemic.

  11. Mind the gap: implementation challenges break the link between HIV/AIDS research and practice

    PubMed Central

    MacCarthy, Sarah; Reisner, Sari; Hoffmann, Michael; Perez-Brumer, Amaya; Silva-Santisteban, Alfonso; Nunn, Amy; Bastos, Leonardo; de Vasconcellos, Mauricio Teixeira Leite; Kerr, Ligia; Bastos, Francisco Inácio; Dourado, Inês

    2018-01-01

    Sampling strategies such as respondent-driven sampling (RDS) and time-location sampling (TLS) offer unique opportunities to access key populations such as men who have sex with men (MSM) and transgender women. Limited work has assessed implementation challenges of these methods. Overcoming implementation challenges can improve research quality and increase uptake of HIV services among key populations. Drawing from studies using RDS in Brazil and TLS in Peru, we summarize challenges encountered in the field and potential strategies to address them. In Brazil, study site selection, cash incentives, and seed selection challenged RDS implementation with MSM. In Peru, expansive geography, safety concerns, and time required for study participation complicated TLS implementation with MSM and transgender women. Formative research, meaningful participation of key populations across stages of research, and transparency in study design are needed to link HIV/AIDS research and practice. Addressing implementation challenges can close gaps in accessing services among those most burdened by the epidemic. PMID:27828609

  12. Quantum phase gate based on electromagnetically induced transparency in optical cavities

    NASA Astrophysics Data System (ADS)

    Borges, Halyne S.; Villas-Bôas, Celso J.

    2016-11-01

    We theoretically investigate the implementation of a quantum controlled-phase gate in a system constituted by a single atom inside an optical cavity, based on the electromagnetically induced transparency effect. First we show that a probe pulse can experience a π phase shift due to the presence or absence of a classical control field. Considering the interplay of the cavity-EIT effect and the quantum memory process, we demonstrated a controlled-phase gate between two single photons. To this end, first one needs to store a (control) photon in the ground atomic states. In the following, a second (target) photon must impinge on the atom-cavity system. Depending on the atomic state, this second photon will be either transmitted or reflected, acquiring different phase shifts. This protocol can then be easily extended to multiphoton systems, i.e., keeping the control photon stored, it may induce phase shifts in several single photons, thus enabling the generation of multipartite entangled states. We explore the relevant parameter space in the atom-cavity system that allows the implementation of quantum controlled-phase gates using the recent technologies. In particular, we have found a lower bound for the cooperativity of the atom-cavity system which enables the implementation of phase shift on single photons. The induced shift on the phase of a photonic qubit and the controlled-phase gate between single photons, combined with optical devices, enable one to perform universal quantum computation.

  13. Ethical issues with colorectal cancer screening-a systematic review.

    PubMed

    Hofmann, Bjørn

    2017-06-01

    Colorectal cancer (CRC) screening is widely recommended and implemented. However, sometimes CRC screening is not implemented despite good evidence, and some types of CRC screening are implemented despite lack of evidence. The objective of this article is to expose and elucidate relevant ethical issues in the literature on CRC screening that are important for open and transparent deliberation on CRC screening. An axiological question-based method is used for exposing and elucidating ethical issues relevant in HTA. A literature search in MEDLINE, Embase, PsycINFO, PubMed Bioethics subset, ISI Web of Knowledge, Bioethics Literature Database (BELIT), Ethics in Medicine (ETHMED), SIBIL Base dati di bioetica, LEWI Bibliographic Database on Ethics in the Sciences and Humanities, and EUROETHICS identified 870 references of which 114 were found relevant according to title and abstract. The content of the included papers were subject to ethical analysis to highlight the ethical issues, concerns, and arguments. A wide range of important ethical issues were identified. The main benefits are reduced relative CRC mortality rate, and potentially incidence rate, but there is no evidence of reduced absolute mortality rate. Potential harms are bleeding, perforation, false test results, overdetection, overdiagnosis, overtreatment (including unnecessary removal of polyps), and (rarely) death. Other important issues are related to autonomy and informed choice equity, justice, medicalization, and expanding disease. A series of important ethical issues have been identified and need to be addressed in open and transparent deliberation on CRC screening. © 2016 John Wiley & Sons, Ltd.

  14. Four challenges in selecting and implementing methods to monitor and evaluate participatory processes: Example from the Rwenzori region, Uganda.

    PubMed

    Hassenforder, Emeline; Ducrot, Raphaëlle; Ferrand, Nils; Barreteau, Olivier; Anne Daniell, Katherine; Pittock, Jamie

    2016-09-15

    Participatory approaches are now increasingly recognized and used as an essential element of policies and programs, especially in regards to natural resource management (NRM). Most practitioners, decision-makers and researchers having adopted participatory approaches also acknowledge the need to monitor and evaluate such approaches in order to audit their effectiveness, support decision-making or improve learning. Many manuals and frameworks exist on how to carry out monitoring and evaluation (M&E) for participatory processes. However, few provide guidelines on the selection and implementation of M&E methods, an aspect which is also often obscure in published studies, at the expense of the transparency, reliability and validity of the study. In this paper, we argue that the selection and implementation of M&E methods are particularly strategic when monitoring and evaluating a participatory process. We demonstrate that evaluators of participatory processes have to tackle a quadruple challenge when selecting and implementing methods: using mixed-methods, both qualitative and quantitative; assessing the participatory process, its outcomes, and its context; taking into account both the theory and participants' views; and being both rigorous and adaptive. The M&E of a participatory planning process in the Rwenzori Region, Uganda, is used as an example to show how these challenges unfold on the ground and how they can be tackled. Based on this example, we conclude by providing tools and strategies that can be used by evaluators to ensure that they make utile, feasible, coherent, transparent and adaptive methodological choices when monitoring and evaluating participatory processes for NRM. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Designing Transparent Teacher Evaluation: The Role of Oversight Panels for Professional Accountability

    ERIC Educational Resources Information Center

    Goldstein, Jennifer

    2009-01-01

    Background/Context: Peer Assistance and Review (PAR), or peer review as it has historically been called, has existed in a handful of school districts since the early 1980s. In 1999, California became the first state to pass PAR legislation; at that time, a major district had not implemented the policy in over a decade. Setting: This is an in-depth…

  16. Improving the Implementation of an United States Accrediting Agency's Retention Standard through Best Practices: An Action Research Study

    ERIC Educational Resources Information Center

    King, Terron A.

    2016-01-01

    Over the last decade, higher education has come under intense scrutiny from the government; accrediting agencies in particular have come under fire for a lack of accountability and transparency. Reports from the Commission on the Future of Higher Education and the Health, Education, Labor and Pensions (HELP) Committee served as a driving force for…

  17. From Onions to Shallots: Rewarding Tor Relays with TEARS

    DTIC Science & Technology

    2014-07-18

    distributed banking using protocols from distributed digital cryp- tocurrency systems like Bitcoin . Shallots are publicly-verifiable, minimiz- ing reliance on...model; none of these have yet been implemented. In this paper, we draw upon the distributed Bitcoin architecture to design a transparent, efficient, and... Bitcoin . Shallots are publicly-veri able, minimiz- ing reliance on and trust in banking authorities, making them auditable while naturally distributing

  18. A Systematic and Transparent Approach for Assessing the Methodological Quality of Intervention Effectiveness Research: The Study Design and Implementation Assessment Device (Study DIAD)

    ERIC Educational Resources Information Center

    Valentine, Jeffrey C.; Cooper, Harris

    2008-01-01

    Assessments of studies meant to evaluate the effectiveness of interventions, programs, and policies can serve an important role in the interpretation of research results. However, evidence suggests that available quality assessment tools have poor measurement characteristics and can lead to opposing conclusions when applied to the same body of…

  19. Digital technology for health sector governance in low and middle income countries: a scoping review.

    PubMed

    Holeman, Isaac; Cookson, Tara Patricia; Pagliari, Claudia

    2016-12-01

    Poor governance impedes the provision of equitable and cost-effective health care in many low- and middle-income countries (LMICs). Although systemic problems such as corruption and inefficiency have been characterized as intractable, "good governance" interventions that promote transparency, accountability and public participation have yielded encouraging results. Mobile phones and other Information and Communication Technologies (ICTs) are beginning to play a role in these interventions, but little is known about their use and effects in the context of LMIC health care. Multi-stage scoping review: Research questions and scope were refined through a landscape scan of relevant implementation activities and by analyzing related concepts in the literature. Relevant studies were identified through iterative Internet searches (Google, Google Scholar), a systematic search of academic databases (PubMed, Web of Science), social media crowdsourcing (targeted LinkedIn and Twitter appeals) and reading reference lists and websites of relevant organizations. Parallel expert interviews helped to verify concepts and emerging findings and identified additional studies for inclusion. Results were charted, analyzed thematically and summarized. We identified 34 articles from a wide range of disciplines and sectors, including 17 published research articles and 17 grey literature reports. Analysis of these articles revealed 15 distinct ways of using ICTs for good governance activities in LMIC health care. These use cases clustered into four conceptual categories: 1) gathering and verifying information on services to improve transparency and auditability 2) aggregating and visualizing data to aid communication and decision making 3) mobilizing citizens in reporting poor practices to improve accountability and quality and 4) automating and auditing processes to prevent fraud. Despite a considerable amount of implementation activity, we identified little formal evaluative research. Innovative digital approaches are increasingly being used to facilitate good governance in the health sectors of LMICs but evidence of their effectiveness is still limited. More empirical studies are needed to measure concrete impacts, document mechanisms of action, and elucidate the political and sociotechnical dynamics that make designing and implementing ICTs for good governance so complex. Many digital good governance interventions are driven by an assumption that transparency alone will effect change; however responsive feedback mechanisms are also likely to be necessary.

  20. Development, implementation and evaluation of an evidence-based program for introduction of new health technologies and clinical practices in a local healthcare setting.

    PubMed

    Harris, Claire; Garrubba, Marie; Allen, Kelly; King, Richard; Kelly, Cate; Thiagarajan, Malar; Castleman, Beverley; Ramsey, Wayne; Farjou, Dina

    2015-12-28

    This paper reports the process of establishing a transparent, accountable, evidence-based program for introduction of new technologies and clinical practices (TCPs) in a large Australian healthcare network. Many countries have robust evidence-based processes for assessment of new TCPs at national level. However many decisions are made by local health services where the resources and expertise to undertake health technology assessment (HTA) are limited and a lack of structure, process and transparency has been reported. An evidence-based model for process change was used to establish the program. Evidence from research and local data, experience of health service staff and consumer perspectives were incorporated at each of four steps: identifying the need for change, developing a proposal, implementation and evaluation. Checklists assessing characteristics of success, factors for sustainability and barriers and enablers were applied and implementation strategies were based on these findings. Quantitative and qualitative methods were used for process and outcome evaluation. An action research approach underpinned ongoing refinement to systems, processes and resources. A Best Practice Guide developed from the literature and stakeholder consultation identified seven program components: Governance, Decision-Making, Application Process, Monitoring and Reporting, Resources, Administration, and Evaluation and Quality Improvement. The aims of transparency and accountability were achieved. The processes are explicit, decisions published, outcomes recorded and activities reported. The aim of ascertaining rigorous evidence-based information for decision-making was not achieved in all cases. Applicants proposing new TCPs provided the evidence from research literature and local data however the information was often incorrect or inadequate, overestimating benefits and underestimating costs. Due to these limitations the initial application process was replaced by an Expression of Interest from applicants followed by a rigorous HTA by independent in-house experts. The program is generalisable to most health care organisations. With one exception, the components would be achievable with minimal additional resources; the lack of skills and resources required for HTA will limit effective application in many settings. A toolkit containing details of the processes and sample materials is provided to facilitate replication or local adaptation by those wishing to establish a similar program.

  1. How Are New Vaccines Prioritized in Low-Income Countries? A Case Study of Human Papilloma Virus Vaccine and Pneumococcal Conjugate Vaccine in Uganda

    PubMed Central

    Wallace, Lauren; Kapirir, Lydia

    2017-01-01

    Background: To date, research on priority-setting for new vaccines has not adequately explored the influence of the global, national and sub-national levels of decision-making or contextual issues such as political pressure and stakeholder influence and power. Using Kapiriri and Martin’s conceptual framework, this paper evaluates priority setting for new vaccines in Uganda at national and sub-national levels, and considers how global priorities can influence country priorities. This study focuses on 2 specific vaccines, the human papilloma virus (HPV) vaccine and the pneumococcal conjugate vaccine (PCV). Methods: This was a qualitative study that involved reviewing relevant Ugandan policy documents and media reports, as well as 54 key informant interviews at the global level and national and sub-national levels in Uganda. Kapiriri and Martin’s conceptual framework was used to evaluate the prioritization process. Results: Priority setting for PCV and HPV was conducted by the Ministry of Health (MoH), which is considered to be a legitimate institution. While respondents described the priority setting process for PCV process as transparent, participatory, and guided by explicit relevant criteria and evidence, the prioritization of HPV was thought to have been less transparent and less participatory. Respondents reported that neither process was based on an explicit priority setting framework nor did it involve adequate representation from the districts (program implementers) or publicity. The priority setting process for both PCV and HPV was negatively affected by the larger political and economic context, which contributed to weak institutional capacity as well as power imbalances between development assistance partners and the MoH. Conclusion: Priority setting in Uganda would be improved by strengthening institutional capacity and leadership and ensuring a transparent and participatory processes in which key stakeholders such as program implementers (the districts) and beneficiaries (the public) are involved. Kapiriri and Martin’s framework has the potential to guide priority setting evaluation efforts, however, evaluation should be built into the priority setting process a priori such that information on priority setting is gathered throughout the implementation cycle. PMID:29172378

  2. Mobile Pit verification system design based on passive special nuclear material verification in weapons storage facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul, J. N.; Chin, M. R.; Sjoden, G. E.

    2013-07-01

    A mobile 'drive by' passive radiation detection system to be applied in special nuclear materials (SNM) storage facilities for validation and compliance purposes has been designed through the use of computational modeling and new radiation detection methods. This project was the result of work over a 1 year period to create optimal design specifications to include creation of 3D models using both Monte Carlo and deterministic codes to characterize the gamma and neutron leakage out each surface of SNM-bearing canisters. Results were compared and agreement was demonstrated between both models. Container leakages were then used to determine the expected reactionmore » rates using transport theory in the detectors when placed at varying distances from the can. A 'typical' background signature was incorporated to determine the minimum signatures versus the probability of detection to evaluate moving source protocols with collimation. This established the criteria for verification of source presence and time gating at a given vehicle speed. New methods for the passive detection of SNM were employed and shown to give reliable identification of age and material for highly enriched uranium (HEU) and weapons grade plutonium (WGPu). The finalized 'Mobile Pit Verification System' (MPVS) design demonstrated that a 'drive-by' detection system, collimated and operating at nominally 2 mph, is capable of rapidly verifying each and every weapon pit stored in regularly spaced, shelved storage containers, using completely passive gamma and neutron signatures for HEU and WGPu. This system is ready for real evaluation to demonstrate passive total material accountability in storage facilities. (authors)« less

  3. Effect of reactor radiation on the thermal conductivity of TREAT fuel

    DOE PAGES

    Mo, Kun; Miao, Yinbin; Kontogeorgakos, Dimitrios C.; ...

    2017-02-04

    The Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory is resuming operations after more than 20 years in latency in order to produce high-neutron-flux transients for investigating transient-induced behavior of reactor fuels and their interactions with other materials and structures. A parallel program is ongoing to develop a replacement core in which the fuel, historically containing highly-enriched uranium (HEU), is replaced by low-enriched uranium (LEU). Both the HEU and prospective LEU fuels are in the form of UO 2 particles dispersed in a graphite matrix, but the LEU fuel will contain a much higher volume of UO 2more » particles, which may create a larger area of interphase boundaries between the particles and the graphite. This may lead to a higher volume fraction of graphite exposed to the fission fragments escaping from the UO 2 particles, and thus may induce a higher volume of fission-fragment damage on the fuel graphite. In this work, we analyzed the reactor-radiation induced thermal conductivity degradation of graphite-based dispersion fuel. A semi-empirical method to model the relative thermal conductivity with reactor radiation was proposed and validated based on the available experimental data. Prediction of thermal conductivity degradation of LEU TREAT fuel during a long-term operation was performed, with a focus on the effect of UO 2 particle size on fission-fragment damage. Lastly, the proposed method can be further adjusted to evaluate the degradation of other properties of graphite-based dispersion fuel.« less

  4. Conversion Preliminary Safety Analysis Report for the NIST Research Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diamond, D. J.; Baek, J. S.; Hanson, A. L.

    The NIST Center for Neutron Research (NCNR) is a reactor-laboratory complex providing the National Institute of Standards and Technology (NIST) and the nation with a world-class facility for the performance of neutron-based research. The heart of this facility is the NIST research reactor (aka NBSR); a heavy water moderated and cooled reactor operating at 20 MW. It is fueled with high-enriched uranium (HEU) fuel elements. A Global Threat Reduction Initiative (GTRI) program is underway to convert the reactor to low-enriched uranium (LEU) fuel. This program includes the qualification of the proposed fuel, uranium and molybdenum alloy foil clad in anmore » aluminum alloy, and the development of the fabrication techniques. This report is a preliminary version of the Safety Analysis Report (SAR) that would be submitted to the U.S. Nuclear Regulatory Commission (NRC) for approval prior to conversion. The report follows the recommended format and content from the NRC codified in NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-power Reactors,” Chapter 18, “Highly Enriched to Low-Enriched Uranium Conversions.” The emphasis in any conversion SAR is to explain the differences between the LEU and HEU cores and to show the acceptability of the new design; there is no need to repeat information regarding the current reactor that will not change upon conversion. Hence, as seen in the report, the bulk of the SAR is devoted to Chapter 4, Reactor Description, and Chapter 13, Safety Analysis.« less

  5. Analysis of LOCA Scenarios in the NIST Research Reactor Before and After Fuel Conversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baek, J. S.; Cheng, L. Y.; Diamond, D.

    An analysis has been done of hypothetical loss-of-coolant-accidents (LOCAs) in the research reactor (NBSR) at the National Institute of Standards and Technology (NIST). The purpose of the analysis is to determine if the peak clad temperature remains below the Safety Limit, which is the blister temperature for the fuel. The configuration of the NBSR considered in the analysis is that projected for the future when changes will be made so that shutdown pumps do not operate when a LOCA signal is detected. The analysis was done for the present core with high-enriched uranium (HEU) fuel and with the proposed low-enrichedmore » uranium (LEU) fuel that would be used when the NBSR is converted from one to the other. The analysis consists of two parts. The first examines how the water would drain from the primary system following a break and the possibility for the loss of coolant from within the fuel element flow channels. This work is performed using the TRACE system thermal-hydraulic code. The second looks at the fuel clad temperature as a function of time given that the water may have drained from many of the flow channels and the water in the vessel is in a quasi-equilibrium state. The temperature behavior is investigated using the three-dimensional heat conduction code HEATING7.3. The results in all scenarios considered for both HEU and LEU fuel show that the peak clad temperature remains below the blister temperature.« less

  6. Effect of reactor radiation on the thermal conductivity of TREAT fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mo, Kun; Miao, Yinbin; Kontogeorgakos, Dimitrios C.

    The Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory is resuming operations after more than 20 years in latency in order to produce high-neutron-flux transients for investigating transient-induced behavior of reactor fuels and their interactions with other materials and structures. A parallel program is ongoing to develop a replacement core in which the fuel, historically containing highly-enriched uranium (HEU), is replaced by low-enriched uranium (LEU). Both the HEU and prospective LEU fuels are in the form of UO 2 particles dispersed in a graphite matrix, but the LEU fuel will contain a much higher volume of UO 2more » particles, which may create a larger area of interphase boundaries between the particles and the graphite. This may lead to a higher volume fraction of graphite exposed to the fission fragments escaping from the UO 2 particles, and thus may induce a higher volume of fission-fragment damage on the fuel graphite. In this work, we analyzed the reactor-radiation induced thermal conductivity degradation of graphite-based dispersion fuel. A semi-empirical method to model the relative thermal conductivity with reactor radiation was proposed and validated based on the available experimental data. Prediction of thermal conductivity degradation of LEU TREAT fuel during a long-term operation was performed, with a focus on the effect of UO 2 particle size on fission-fragment damage. Lastly, the proposed method can be further adjusted to evaluate the degradation of other properties of graphite-based dispersion fuel.« less

  7. Supplemental Thermal-Hydraulic Transient Analyses of BR2 in Support of Conversion to LEU Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Licht, J.; Dionne, B.; Sikik, E.

    2016-01-01

    Belgian Reactor 2 (BR2) is a research and test reactor located in Mol, Belgium and is primarily used for radioisotope production and materials testing. The Materials Management and Minimization (M3) Reactor Conversion Program of the National Nuclear Security Administration (NNSA) is supporting the conversion of the BR2 reactor from Highly Enriched Uranium (HEU) fuel to Low Enriched Uranium (LEU) fuel. The RELAP5/Mod 3.3 code has been used to perform transient thermal-hydraulic safety analyses of the BR2 reactor to support reactor conversion. A RELAP5 model of BR2 has been validated against select transient BR2 reactor experiments performed in 1963 by showingmore » agreement with measured cladding temperatures. Following the validation, the RELAP5 model was then updated to represent the current use of the reactor; taking into account core configuration, neutronic parameters, trip settings, component changes, etc. Simulations of the 1963 experiments were repeated with this updated model to re-evaluate the boiling risks associated with the currently allowed maximum heat flux limit of 470 W/cm 2 and temporary heat flux limit of 600 W/cm 2. This document provides analysis of additional transient simulations that are required as part of a modern BR2 safety analysis report (SAR). The additional simulations included in this report are effect of pool temperature, reduced steady-state flow rate, in-pool loss of coolant accidents, and loss of external cooling. The simulations described in this document have been performed for both an HEU- and LEU-fueled core.« less

  8. Laser-driven deflection arrangements and methods involving charged particle beams

    DOEpatents

    Plettner, Tomas [San Ramon, CA; Byer, Robert L [Stanford, CA

    2011-08-09

    Systems, methods, devices and apparatus are implemented for producing controllable charged particle beams. In one implementation, an apparatus provides a deflection force to a charged particle beam. A source produces an electromagnetic wave. A structure, that is substantially transparent to the electromagnetic wave, includes a physical structure having a repeating pattern with a period L and a tilted angle .alpha., relative to a direction of travel of the charged particle beam, the pattern affects the force of the electromagnetic wave upon the charged particle beam. A direction device introduces the electromagnetic wave to the structure to provide a phase-synchronous deflection force to the charged particle beam.

  9. A framework for learning about improvement: embedded implementation and evaluation design to optimize learning

    PubMed Central

    Barry, Danika; Kimble, Leighann E; Nambiar, Bejoy; Parry, Gareth; Jha, Ashish; Chattu, Vijay Kumar; Massoud, M Rashad; Goldmann, Don

    2018-01-01

    Abstract Improving health care involves many actors, often working in complex adaptive systems. Interventions tend to be multi-factorial, implementation activities diverse, and contexts dynamic and complicated. This makes improvement initiatives challenging to describe and evaluate as matching evaluation and program designs can be difficult, requiring collaboration, trust and transparency. Collaboration is required to address important epidemiological principles of bias and confounding. If this does not take place, results may lack credibility because the association between interventions implemented and outcomes achieved is obscure and attribution uncertain. Moreover, lack of clarity about what was implemented, how it was implemented, and the context in which it was implemented often lead to disappointment or outright failure of spread and scale-up efforts. The input of skilled evaluators into the design and conduct of improvement initiatives can be helpful in mitigating these potential problems. While evaluation must be rigorous, if it is too rigid necessary adaptation and learning may be compromised. This article provides a framework and guidance on how improvers and evaluators can work together to design, implement and learn about improvement interventions more effectively. PMID:29873794

  10. Beam position monitor gate functionality implementation and applications

    DOE PAGES

    Cheng, Weixing; Ha, Kiman; Li, Yongjun; ...

    2018-06-14

    We introduce a novel technique to implement gate functionality for the beam position monitors (BPM) at the National Synchrotron Light Source II (NSLS-II). The functionality, now implemented in FPGA, allows us to acquire two separated bunch-trains’ synchronized turn-by-turn (TBT) data simultaneously with the NSLS-II in-house developed BPM system. The gated position resolution is improved about 3 times by narrowing the sampling width. Experimentally we demonstrated that the machine lattice could be transparently characterized with the gated TBT data of a short diagnostic bunch-train Cheng et al., 2017; Li et al., 2017. Other applications, for example, precisely characterizing storage ring impedance/wake-fieldmore » through recording the beam positions of two separated bunch trains has been experimentally demonstrated.« less

  11. A Framework for Enhancing the Value of Research for Dissemination and Implementation

    PubMed Central

    Glasgow, Russell E.; Carpenter, Christopher R.; Grimshaw, Jeremy M.; Rabin, Borsika A.; Fernandez, Maria E.; Brownson, Ross C.

    2015-01-01

    A comprehensive guide that identifies critical evaluation and reporting elements necessary to move research into practice is needed. We propose a framework that highlights the domains required to enhance the value of dissemination and implementation research for end users. We emphasize the importance of transparent reporting on the planning phase of research in addition to delivery, evaluation, and long-term outcomes. We highlight key topics for which well-established reporting and assessment tools are underused (e.g., cost of intervention, implementation strategy, adoption) and where such tools are inadequate or lacking (e.g., context, sustainability, evolution) within the context of existing reporting guidelines. Consistent evaluation of and reporting on these issues with standardized approaches would enhance the value of research for practitioners and decision-makers. PMID:25393182

  12. Beam position monitor gate functionality implementation and applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Weixing; Ha, Kiman; Li, Yongjun

    We introduce a novel technique to implement gate functionality for the beam position monitors (BPM) at the National Synchrotron Light Source II (NSLS-II). The functionality, now implemented in FPGA, allows us to acquire two separated bunch-trains’ synchronized turn-by-turn (TBT) data simultaneously with the NSLS-II in-house developed BPM system. The gated position resolution is improved about 3 times by narrowing the sampling width. Experimentally we demonstrated that the machine lattice could be transparently characterized with the gated TBT data of a short diagnostic bunch-train Cheng et al., 2017; Li et al., 2017. Other applications, for example, precisely characterizing storage ring impedance/wake-fieldmore » through recording the beam positions of two separated bunch trains has been experimentally demonstrated.« less

  13. Simplified microprocessor design for VLSI control applications

    NASA Technical Reports Server (NTRS)

    Cameron, K.

    1991-01-01

    A design technique for microprocessors combining the simplicity of reduced instruction set computers (RISC's) with the richer instruction sets of complex instruction set computers (CISC's) is presented. They utilize the pipelined instruction decode and datapaths common to RISC's. Instruction invariant data processing sequences which transparently support complex addressing modes permit the formulation of simple control circuitry. Compact implementations are possible since neither complicated controllers nor large register sets are required.

  14. Review of digital holography reconstruction methods

    NASA Astrophysics Data System (ADS)

    Dovhaliuk, Rostyslav Yu.

    2018-01-01

    Development of digital holography opened new ways of both transparent and opaque objects non-destructive study. In this paper, a digital hologram reconstruction process is investigated. The advantages and limitations of common wave propagation methods are discussed. The details of a software implementation of a digital hologram reconstruction methods are presented. Finally, the performance of each wave propagation method is evaluated, and recommendations about possible use cases for each of them are given.

  15. Risk and Outbreak Communication: Lessons from Taiwan's Experiences in the Post-SARS Era.

    PubMed

    Hsu, Yu-Chen; Chen, Yu-Ling; Wei, Han-Ning; Yang, Yu-Wen; Chen, Ying-Hwei

    In addition to the impact of a disease itself, public reaction could be considered another outbreak to be controlled during an epidemic. Taiwan's experience with SARS in 2003 highlighted the critical role played by the media during crisis communication. After the SARS outbreak, Taiwan's Centers for Disease Control (Taiwan CDC) followed the WHO outbreak communication guidelines on trust, early announcements, transparency, informing the public, and planning, in order to reform its risk communication systems. This article describes the risk communication framework in Taiwan, which has been used to respond to the 2009-2016 influenza epidemics, Ebola in West Africa (2014-16), and MERS-CoV in South Korea (2015) during the post-SARS era. Many communication strategies, ranging from traditional media to social and new media, have been implemented to improve transparency in public communication and promote civic engagement. Taiwan CDC will continue to maintain the strengths of its risk communication systems and resolve challenges as they emerge through active evaluation and monitoring of public opinion to advance Taiwan's capacity in outbreak communication and control. Moreover, Taiwan CDC will continue to implement the IHR (2005) and to promote a global community working together to fight shared risks and to reach the goal of "One World, One Health."

  16. Life cycle of medical product rules issued by the US Food and Drug Administration.

    PubMed

    Hwang, Thomas J; Avorn, Jerry; Kesselheim, Aaron S

    2014-08-01

    The US Food and Drug Administration (FDA) uses rulemaking as one of its primary tools to protect the public health and implement laws enacted by Congress and the president. Because of the many effects that these rules have on social welfare and the economy, the FDA and other executive agencies receive input from the executive branch, the public, and in some cases, the courts, during the process of rulemaking. In this article, we examine the life cycle of FDA regulations concerning medical products and review notable features of the rulemaking process. The current system grants substantial opportunities for diverse stakeholders to participate in and influence how rules are written and implemented. However, the duration, complexity, and adversarial qualities of the rulemaking process can hinder the FDA's ability to achieve its policy and public health goals. There is considerable variation in the level of transparency at different stages in the process, ranging from freely accessible public comments to undisclosed internal agency deliberations. In addition, significant medical product rules are associated with lengthy times to finalization, in some cases for unclear reasons. We conclude by identifying potential areas for reform on the basis of transparency and efficiency. Copyright © 2014 by Duke University Press.

  17. A Comparison of Four Software Programs for Implementing Decision Analytic Cost-Effectiveness Models.

    PubMed

    Hollman, Chase; Paulden, Mike; Pechlivanoglou, Petros; McCabe, Christopher

    2017-08-01

    The volume and technical complexity of both academic and commercial research using decision analytic modelling has increased rapidly over the last two decades. The range of software programs used for their implementation has also increased, but it remains true that a small number of programs account for the vast majority of cost-effectiveness modelling work. We report a comparison of four software programs: TreeAge Pro, Microsoft Excel, R and MATLAB. Our focus is on software commonly used for building Markov models and decision trees to conduct cohort simulations, given their predominance in the published literature around cost-effectiveness modelling. Our comparison uses three qualitative criteria as proposed by Eddy et al.: "transparency and validation", "learning curve" and "capability". In addition, we introduce the quantitative criterion of processing speed. We also consider the cost of each program to academic users and commercial users. We rank the programs based on each of these criteria. We find that, whilst Microsoft Excel and TreeAge Pro are good programs for educational purposes and for producing the types of analyses typically required by health technology assessment agencies, the efficiency and transparency advantages of programming languages such as MATLAB and R become increasingly valuable when more complex analyses are required.

  18. SDS: A Framework for Scientific Data Services

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Bin; Byna, Surendra; Wu, Kesheng

    2013-10-31

    Large-scale scientific applications typically write their data to parallel file systems with organizations designed to achieve fast write speeds. Analysis tasks frequently read the data in a pattern that is different from the write pattern, and therefore experience poor I/O performance. In this paper, we introduce a prototype framework for bridging the performance gap between write and read stages of data access from parallel file systems. We call this framework Scientific Data Services, or SDS for short. This initial implementation of SDS focuses on reorganizing previously written files into data layouts that benefit read patterns, and transparently directs read callsmore » to the reorganized data. SDS follows a client-server architecture. The SDS Server manages partial or full replicas of reorganized datasets and serves SDS Clients' requests for data. The current version of the SDS client library supports HDF5 programming interface for reading data. The client library intercepts HDF5 calls and transparently redirects them to the reorganized data. The SDS client library also provides a querying interface for reading part of the data based on user-specified selective criteria. We describe the design and implementation of the SDS client-server architecture, and evaluate the response time of the SDS Server and the performance benefits of SDS.« less

  19. Risk and Outbreak Communication: Lessons from Taiwan's Experiences in the Post-SARS Era

    PubMed Central

    Chen, Yu-Ling; Wei, Han-Ning; Yang, Yu-Wen; Chen, Ying-Hwei

    2017-01-01

    In addition to the impact of a disease itself, public reaction could be considered another outbreak to be controlled during an epidemic. Taiwan's experience with SARS in 2003 highlighted the critical role played by the media during crisis communication. After the SARS outbreak, Taiwan's Centers for Disease Control (Taiwan CDC) followed the WHO outbreak communication guidelines on trust, early announcements, transparency, informing the public, and planning, in order to reform its risk communication systems. This article describes the risk communication framework in Taiwan, which has been used to respond to the 2009-2016 influenza epidemics, Ebola in West Africa (2014-16), and MERS-CoV in South Korea (2015) during the post-SARS era. Many communication strategies, ranging from traditional media to social and new media, have been implemented to improve transparency in public communication and promote civic engagement. Taiwan CDC will continue to maintain the strengths of its risk communication systems and resolve challenges as they emerge through active evaluation and monitoring of public opinion to advance Taiwan's capacity in outbreak communication and control. Moreover, Taiwan CDC will continue to implement the IHR (2005) and to promote a global community working together to fight shared risks and to reach the goal of “One World, One Health.” PMID:28418746

  20. Leo Szilard Lectureship Award: Science Matters - Technical Dimensions of Arms Control and Non-Proliferation Agreements

    NASA Astrophysics Data System (ADS)

    Timbie, James

    2017-01-01

    Agreements to reduce nuclear arms and prevent proliferation of nuclear weapons are technical as well as political documents. They must be both technically sound and politically acceptable. This presentation illustrates technical aspects of arms control and non-proliferation agreements, with examples from SALT I, INF, the HEU Agreement, START, and the Iran nuclear negotiations, drawing on 44 years of personal experience in the negotiation of these agreements. The lecture is designed to convey an appreciation of the role that individuals with technical training can play in diplomatic efforts to reduce nuclear forces and prevent nuclear proliferation.

  1. The evolution to transparent optical networking

    NASA Astrophysics Data System (ADS)

    Wrage, Marc; Kirstaedter, Andreas; Rohde, Harald

    2005-02-01

    Optical data transmission has undergone a tremendous evolution. Starting with unrepeated point-to-point transmission in the 80s the inventions of wavelength division multiplexing (WDM) and erbium doped fiber amplifiers (EDFAs) have let to an explosion of system capacity as well as of system reach. After the steep downturn of recent years network operators have now regained the strength to upgrade their networks and to implement new services. This paper will review current and upcoming technologies in the long haul (LH) and ultra long haul (ULH) data transmission. It will further discuss the future evolution of transparent optical networks towards dynamically routed meshed optical networks with respect to operator"s technical operational and economical requirements. Upgradeability turns out as a key issue as it on the one hand side facilitates low front investments for network providers and on the other hand side enables organic and flexible network growth.

  2. Secure and Trustable Electronic Medical Records Sharing using Blockchain.

    PubMed

    Dubovitskaya, Alevtina; Xu, Zhigang; Ryu, Samuel; Schumacher, Michael; Wang, Fusheng

    2017-01-01

    Electronic medical records (EMRs) are critical, highly sensitive private information in healthcare, and need to be frequently shared among peers. Blockchain provides a shared, immutable and transparent history of all the transactions to build applications with trust, accountability and transparency. This provides a unique opportunity to develop a secure and trustable EMR data management and sharing system using blockchain. In this paper, we present our perspectives on blockchain based healthcare data management, in particular, for EMR data sharing between healthcare providers and for research studies. We propose a framework on managing and sharing EMR data for cancer patient care. In collaboration with Stony Brook University Hospital, we implemented our framework in a prototype that ensures privacy, security, availability, and fine-grained access control over EMR data. The proposed work can significantly reduce the turnaround time for EMR sharing, improve decision making for medical care, and reduce the overall cost.

  3. Secure and Trustable Electronic Medical Records Sharing using Blockchain

    PubMed Central

    Dubovitskaya, Alevtina; Xu, Zhigang; Ryu, Samuel; Schumacher, Michael; Wang, Fusheng

    2017-01-01

    Electronic medical records (EMRs) are critical, highly sensitive private information in healthcare, and need to be frequently shared among peers. Blockchain provides a shared, immutable and transparent history of all the transactions to build applications with trust, accountability and transparency. This provides a unique opportunity to develop a secure and trustable EMR data management and sharing system using blockchain. In this paper, we present our perspectives on blockchain based healthcare data management, in particular, for EMR data sharing between healthcare providers and for research studies. We propose a framework on managing and sharing EMR data for cancer patient care. In collaboration with Stony Brook University Hospital, we implemented our framework in a prototype that ensures privacy, security, availability, and fine-grained access control over EMR data. The proposed work can significantly reduce the turnaround time for EMR sharing, improve decision making for medical care, and reduce the overall cost. PMID:29854130

  4. Investigation using data from ERTS-1 to develop and implement utilization of living marine resources. [availability and distribution of menhaden fish in Mississippi Sound and Gulf waters

    NASA Technical Reports Server (NTRS)

    Stevenson, W. H. (Principal Investigator); Pastula, E. J., Jr.

    1973-01-01

    The author has identified the following significant results. This 15-month ERTS-1 investigation produced correlations between satellite, aircraft, menhaden fisheries, and environmental sea truth data from the Mississippi Sound. Selected oceanographic, meteorological, and biological parameters were used as indirect indicators of the menhaden resource. Synoptic and near real time sea truth, fishery, satellite imagery, aircraft acquired multispectral, photo and thermal IR information were acquired as data inputs. Computer programs were developed to manipulate these data according to user requirements. Preliminary results indicate a correlation between backscattered light with chlorophyll concentration and water transparency in turbid waters. Eight empirical menhaden distribution models were constructed from combinations of four fisheries-significant oceanographic parameters: water depth, transparency, color, and surface salinity. The models demonstrated their potential for management utilization in areas of resource assessment, prediction, and monitoring.

  5. Rationalisation and Validation of an Acrylamide-Free Procedure in Three-Dimensional Histological Imaging

    PubMed Central

    Lai, Hei Ming; Liu, Alan King Lun; Ng, Wai-Lung; DeFelice, John; Lee, Wing Sang; Li, Heng; Li, Wen; Ng, Ho Man; Chang, Raymond Chuen-Chung; Lin, Bin; Wu, Wutian; Gentleman, Steve M.

    2016-01-01

    Three-dimensional visualization of intact tissues is now being achieved by turning tissues transparent. CLARITY is a unique tissue clearing technique, which features the use of detergents to remove lipids from fixed tissues to achieve optical transparency. To preserve tissue integrity, an acrylamide-based hydrogel has been proposed to embed the tissue. In this study, we examined the rationale behind the use of acrylamide in CLARITY, and presented evidence to suggest that the omission of acrylamide-hydrogel embedding in CLARITY does not alter the preservation of tissue morphology and molecular information in fixed tissues. We therefore propose a novel and simplified workflow for formaldehyde-fixed tissue clearing, which will facilitate the laboratory implementation of this technique. Furthermore, we have investigated the basic tissue clearing process in detail and have highlighted some areas for targeted improvement of technologies essential for the emerging subject of three-dimensional histology. PMID:27359336

  6. The effect of electromagnetically induced transparency in a potassium nanocell

    NASA Astrophysics Data System (ADS)

    Sargsyan, A.; Amiryan, A.; Leroy, C.; Vartanyan, T. A.; Sarkisyan, D.

    2017-07-01

    The effect of electromagnetically induced transparency (EIT) has been experimentally implemented for the first time for the (4 S 1/2-4 P 1/2-4 S 1/2) Λ-system of potassium atom levels in a nanocell with a 770-nm-thick column of atomic vapor. It is shown that, at such a small thickness of the vapor column, the EIT resonance can be observed only when the coupling-laser frequency is in exact resonance with the frequency of the corresponding atomic transition. The EIT resonance disappears even if the coupling-laser frequency differs slightly (by 50 MHz) from that of the corresponding atomic transition, which is due to the high thermal velocity of K atoms. The EIT resonance and related velocity selective optical pumping resonances caused by optical pumping (formed by the coupling) can be simultaneously recorded because of the small ( 462 MHz) hyperfine splitting of the lower 4 S 1/2 level.

  7. Electromagnetically induced transparency control in terahertz metasurfaces based on bright-bright mode coupling

    NASA Astrophysics Data System (ADS)

    Yahiaoui, R.; Burrow, J. A.; Mekonen, S. M.; Sarangan, A.; Mathews, J.; Agha, I.; Searles, T. A.

    2018-04-01

    We demonstrate a classical analog of electromagnetically induced transparency (EIT) in a highly flexible planar terahertz metamaterial (MM) comprised of three-gap split-ring resonators. The keys to achieve EIT in this system are the frequency detuning and hybridization processes between two bright modes coexisting in the same unit cell as opposed to bright-dark modes. We present experimental verification of two bright modes coupling for a terahertz EIT-MM in the context of numerical results and theoretical analysis based on a coupled Lorentz oscillator model. In addition, a hybrid variation of the EIT-MM is proposed and implemented numerically to dynamically tune the EIT window by incorporating photosensitive silicon pads in the split gap region of the resonators. As a result, this hybrid MM enables the active optical control of a transition from the on state (EIT mode) to the off state (dipole mode).

  8. Blockchain protocols in clinical trials: Transparency and traceability of consent.

    PubMed

    Benchoufi, Mehdi; Porcher, Raphael; Ravaud, Philippe

    2017-01-01

    Clinical trial consent for protocols and their revisions should be transparent for patients and traceable for stakeholders. Our goal is to implement a process allowing for collection of patients' informed consent, which is bound to protocol revisions, storing and tracking the consent in a secure, unfalsifiable and publicly verifiable way, and enabling the sharing of this information in real time. For that, we build a consent workflow using a trending technology called Blockchain. This is a distributed technology that brings a built-in layer of transparency and traceability. From a more general and prospective point of view, we believe Blockchain technology brings a paradigmatical shift to the entire clinical research field. We designed a Proof-of-Concept protocol consisting of time-stamping each step of the patient's consent collection using Blockchain, thus archiving and historicising the consent through cryptographic validation in a securely unfalsifiable and transparent way. For each protocol revision, consent was sought again.  We obtained a single document, in an open format, that accounted for the whole consent collection process: a time-stamped consent status regarding each version of the protocol. This document cannot be corrupted and can be checked on any dedicated public website. It should be considered a robust proof of data. However, in a live clinical trial, the authentication system should be strengthened to remove the need for third parties, here trial stakeholders, and give participative control to the peer users. In the future, the complex data flow of a clinical trial could be tracked by using Blockchain, which core functionality, named Smart Contract, could help prevent clinical trial events not occurring in the correct chronological order, for example including patients before they consented or analysing case report form data before freezing the database. Globally, Blockchain could help with reliability, security, transparency and could be a consistent step toward reproducibility.

  9. Blockchain protocols in clinical trials: Transparency and traceability of consent

    PubMed Central

    Benchoufi, Mehdi; Porcher, Raphael; Ravaud, Philippe

    2018-01-01

    Clinical trial consent for protocols and their revisions should be transparent for patients and traceable for stakeholders. Our goal is to implement a process allowing for collection of patients’ informed consent, which is bound to protocol revisions, storing and tracking the consent in a secure, unfalsifiable and publicly verifiable way, and enabling the sharing of this information in real time. For that, we build a consent workflow using a trending technology called Blockchain. This is a distributed technology that brings a built-in layer of transparency and traceability. From a more general and prospective point of view, we believe Blockchain technology brings a paradigmatical shift to the entire clinical research field. We designed a Proof-of-Concept protocol consisting of time-stamping each step of the patient’s consent collection using Blockchain, thus archiving and historicising the consent through cryptographic validation in a securely unfalsifiable and transparent way. For each protocol revision, consent was sought again.  We obtained a single document, in an open format, that accounted for the whole consent collection process: a time-stamped consent status regarding each version of the protocol. This document cannot be corrupted and can be checked on any dedicated public website. It should be considered a robust proof of data. However, in a live clinical trial, the authentication system should be strengthened to remove the need for third parties, here trial stakeholders, and give participative control to the peer users. In the future, the complex data flow of a clinical trial could be tracked by using Blockchain, which core functionality, named Smart Contract, could help prevent clinical trial events not occurring in the correct chronological order, for example including patients before they consented or analysing case report form data before freezing the database. Globally, Blockchain could help with reliability, security, transparency and could be a consistent step toward reproducibility. PMID:29167732

  10. Extinction, seeing and sky transparency monitoring at the Observatorio Astrofísico de Javalambre for J-PAS and J-PLUS calibration and scheduling

    NASA Astrophysics Data System (ADS)

    Vázquez Ramió, H.; Díaz-Martín, M. C.; Varela, J.; Ederoclite, A.; Maícas, N. Lamadrid, J. L.; Abril, J.; Iglesias-Marzoa, R.; Rodríguez, S.; Tilve, V.; Cenarro, A. J.; Antón Bravo, J. L.; Bello Ferrer, R.; Cristóbal-Hornillos, D.; Guillén Civera, L.; Hernández-Fuertes, J.; Jiménez Mejías, D.; Lasso-Cabrera, N. M.; López Alegre, G.; López Sainz, A.; Luis-Simoes, R. M.; Marín-Franch, A.; Moles, M.; Rueda-Teruel, F.; Rueda-Teruel, S.; Suárez López, O.; Yanes-Díaz, A.

    2015-05-01

    The Javalambre-Physics of the Accelerating Universe Astrophysical Survey (J-PAS; see Benítez et al. 2014) and the Javalambre-Photometric Local Universe Survey (J-PLUS) will be conducted at the brand-new Observatorio Astrofísico de Javalambre (OAJ) in Teruel, Spain. J-PLUS is planned to start by the first half of 2015 while J-PAS first light is expected to happen along 2015. Besides the two main telescopes (with 2.5 m and 80 cm apertures), several smaller-sized facilities are present at the OAJ devoted to site characterization and supporting measurements to be used to calibrate the J-PAS and J-PLUS photometry and to feed up the OAJ's Sequencer with the integrated seeing and the sky transparency. These instruments are: i) an extinction monitor, an 11 " telescope estimating the atmospheric extinction to finally obtain the OAJ extinction curve, which is the initial step to J-PAS overall photometric calibration procedure; ii) an 8 " telescope implementing the Differential Image Motion Monitor (DIMM) technique to obtain the integrated seeing; and iii) an All-Sky Transmission MONitor (ASTMON), a roughly all-sky instrument providing the sky transparency as well as sky brightness and the atmospheric extinction too.

  11. Muscle categorization using PDF estimation and Naive Bayes classification.

    PubMed

    Adel, Tameem M; Smith, Benn E; Stashuk, Daniel W

    2012-01-01

    The structure of motor unit potentials (MUPs) and their times of occurrence provide information about the motor units (MUs) that created them. As such, electromyographic (EMG) data can be used to categorize muscles as normal or suffering from a neuromuscular disease. Using pattern discovery (PD) allows clinicians to understand the rationale underlying a certain muscle characterization; i.e. it is transparent. Discretization is required in PD, which leads to some loss in accuracy. In this work, characterization techniques that are based on estimating probability density functions (PDFs) for each muscle category are implemented. Characterization probabilities of each motor unit potential train (MUPT) are obtained from these PDFs and then Bayes rule is used to aggregate the MUPT characterization probabilities to calculate muscle level probabilities. Even though this technique is not as transparent as PD, its accuracy is higher than the discrete PD. Ultimately, the goal is to use a technique that is based on both PDFs and PD and make it as transparent and as efficient as possible, but first it was necessary to thoroughly assess how accurate a fully continuous approach can be. Using gaussian PDF estimation achieved improvements in muscle categorization accuracy over PD and further improvements resulted from using feature value histograms to choose more representative PDFs; for instance, using log-normal distribution to represent skewed histograms.

  12. Self-aligned photolithography for the fabrication of fully transparent high-voltage devices

    NASA Astrophysics Data System (ADS)

    Zhang, Yonghui; Mei, Zengxia; Huo, Wenxing; Wang, Tao; Liang, Huili; Du, Xiaolong

    2018-05-01

    High-voltage devices, working in the range of hundreds of volts, are indispensable elements in the driving or readout circuits for various kinds of displays, integrated microelectromechanical systems and x-ray imaging sensors. However, the device performances are found hardly uniform or repeatable due to the misalignment issue, which are extremely common for offset drain high-voltage devices. To resolve this issue, this article reports a set of self-aligned photolithography technology for the fabrication of high-voltage devices. High-performance fully-transparent high-voltage thin film transistors, diodes and logic inverters are successfully fabricated with this technology. Unlike other self-aligned routes, opaque masks are introduced on the backside of the transparent substrate to facilitate proximity exposure method. The photolithography process is simulated and analyzed with technology computer aided design simulation to explain the working principle of the proximity exposure method. The substrate thickness is found to be vital for the implementation of this technology based on both simulation and experimental results. The electrical performance of high-voltage devices is dependent on the offset length, which can be delicately modulated by changing the exposure dose. The presented self-aligned photolithography technology is proved to be feasible in high-voltage circuits, demonstrating its huge potential in practical industrial applications.

  13. Improving accountability in vaccine decision-making.

    PubMed

    Timmis, James Kenneth; Black, Steven; Rappuoli, Rino

    2017-11-01

    Healthcare decisions, in particular those affecting entire populations, should be evidence-based and taken by decision-makers sharing broad alignment with affected stakeholders. However, criteria, priorities and procedures for decision-making are sometimes non-transparent, frequently vary considerably across equivalent decision-bodies, do not always consider the broader benefits of new health-measures, and therefore do not necessarily adequately represent the relevant stakeholder-spectrum. Areas covered: To address these issues in the context of the evaluation of new vaccines, we have proposed a first baseline set of core evaluation criteria, primarily selected by members of the vaccine research community, and suggested their implementation in vaccine evaluation procedures. In this communication, we review the consequences and utility of stakeholder-centered core considerations to increase transparency in and accountability of decision-making procedures, in general, and of the benefits gained by their inclusion in Multi-Criteria-Decision-Analysis tools, exemplified by SMART Vaccines, specifically. Expert commentary: To increase effectiveness and comparability of health decision outcomes, decision procedures should be properly standardized across equivalent (national) decision bodies. To this end, including stakeholder-centered criteria in decision procedures would significantly increase their transparency and accountability, support international capacity building to improve health, and reduce societal costs and inequity resulting from suboptimal health decision-making.

  14. Standards for Reporting Implementation Studies (StaRI): explanation and elaboration document

    PubMed Central

    Pinnock, Hilary; Barwick, Melanie; Carpenter, Christopher R; Eldridge, Sandra; Grandes, Gonzalo; Griffiths, Chris J; Rycroft-Malone, Jo; Meissner, Paul; Murray, Elizabeth; Patel, Anita; Sheikh, Aziz; Taylor, Stephanie J C

    2017-01-01

    Objectives Implementation studies are often poorly reported and indexed, reducing their potential to inform the provision of healthcare services. The Standards for Reporting Implementation Studies (StaRI) initiative aims to develop guidelines for transparent and accurate reporting of implementation studies. Methods An international working group developed the StaRI guideline informed by a systematic literature review and e-Delphi prioritisation exercise. Following a face-to-face meeting, the checklist was developed iteratively by email discussion and critical review by international experts. Results The 27 items of the checklist are applicable to the broad range of study designs employed in implementation science. A key concept is the dual strands, represented as 2 columns in the checklist, describing, on the one hand, the implementation strategy and, on the other, the clinical, healthcare or public health intervention being implemented. This explanation and elaboration document details each of the items, explains the rationale and provides examples of good reporting practice. Conclusions Previously published reporting statements have been instrumental in improving reporting standards; adoption by journals and authors may achieve a similar improvement in the reporting of implementation strategies that will facilitate translation of effective interventions into routine practice. PMID:28373250

  15. Safety of Tenofovir Use During Pregnancy: Early Growth Outcomes in HIV-Exposed Uninfected Infants

    PubMed Central

    SIBERRY, George K.; WILLIAMS, Paige L.; MENDEZ, Hermann; SEAGE, George R.; JACOBSON, Denise L.; HAZRA, Rohan; RICH, Kenneth C.; GRINER, Raymond; TASSIOPOULOS, Katherine; KACANEK, Deborah; MOFENSON, Lynne M.; MILLER, Tracie; DiMEGLIO, Linda A.; WATTS, D. Heather

    2012-01-01

    Objective To evaluate the association of tenofovir disoproxil fumarate (TDF) use during pregnancy with early growth parameters in HIV-exposed, uninfected (HEU) infants. Design US-based prospective cohort study of HEU children to examine potential adverse effects of prenatal TDF exposure. Methods We evaluated the association of maternal TDF use during pregnancy with small for gestational age (SGA); low birth weight (LBW, <2.5kg); weight-for-age z-scores (WAZ), length-forage z-scores (LAZ) and head circumference-for-age (HCAZ) z-scores at newborn visit; and LAZ, HCAZ, and WAZ at age one year. Logistic regression models for LBW and SGA were fit, adjusting for maternal and sociodemographic factors. Adjusted linear regression models were used to evaluate LAZ, WAZ and HCAZ by TDF exposure. Results Of 2029 enrolled children with maternal antiretroviral information, TDF was used by 449 (21%) HIV-infected mothers, increasing from 14% in 2003 to 43% in 2010. There was no difference between those exposed to combination regimens with versus without TDF for SGA, LBW, and newborn LAZ and HCAZ. However, at age one year, infants exposed to combination regimens with TDF had significantly lower adjusted mean LAZ and HCAZ than those without TDF (LAZ: −0.17 vs. −0.03, p=0.04; HCAZ: 0.17 vs. 0.42, p=0.02). Conclusions TDF use during pregnancy was not associated with increased risk for LBW or SGA. The slightly lower mean LAZ and HCAZ observed at age one year in TDF-exposed infants are of uncertain significance but underscore the need for additional studies of growth outcomes after TDF use during pregnancy. PMID:22382151

  16. Validation of the WIMSD4M cross-section generation code with benchmark results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deen, J.R.; Woodruff, W.L.; Leal, L.E.

    1995-01-01

    The WIMSD4 code has been adopted for cross-section generation in support of the Reduced Enrichment Research and Test Reactor (RERTR) program at Argonne National Laboratory (ANL). Subsequently, the code has undergone several updates, and significant improvements have been achieved. The capability of generating group-collapsed micro- or macroscopic cross sections from the ENDF/B-V library and the more recent evaluation, ENDF/B-VI, in the ISOTXS format makes the modified version of the WIMSD4 code, WIMSD4M, very attractive, not only for the RERTR program, but also for the reactor physics community. The intent of the present paper is to validate the WIMSD4M cross-section librariesmore » for reactor modeling of fresh water moderated cores. The results of calculations performed with multigroup cross-section data generated with the WIMSD4M code will be compared against experimental results. These results correspond to calculations carried out with thermal reactor benchmarks of the Oak Ridge National Laboratory (ORNL) unreflected HEU critical spheres, the TRX LEU critical experiments, and calculations of a modified Los Alamos HEU D{sub 2}O moderated benchmark critical system. The benchmark calculations were performed with the discrete-ordinates transport code, TWODANT, using WIMSD4M cross-section data. Transport calculations using the XSDRNPM module of the SCALE code system are also included. In addition to transport calculations, diffusion calculations with the DIF3D code were also carried out, since the DIF3D code is used in the RERTR program for reactor analysis and design. For completeness, Monte Carlo results of calculations performed with the VIM and MCNP codes are also presented.« less

  17. Air Shipment of Spent Nuclear Fuel from Romania to Russia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Igor Bolshinsky; Ken Allen; Lucian Biro

    Romania successfully completed the world’s first air shipment of spent nuclear fuel transported in Type B(U) casks under existing international laws and without shipment license special exceptions when the last Romanian highly enriched uranium (HEU) spent nuclear fuel was transported to the Russian Federation in June 2009. This air shipment required the design, fabrication, and licensing of special 20 foot freight containers and cask tiedown supports to transport the eighteen TUK 19 shipping casks on a Russian commercial cargo aircraft. The new equipment was certified for transport by road, rail, water, and air to provide multi modal transport capabilities formore » shipping research reactor spent fuel. The equipment design, safety analyses, and fabrication were performed in the Russian Federation and transport licenses were issued by both the Russian and Romanian regulatory authorities. The spent fuel was transported by truck from the VVR S research reactor to the Bucharest airport, flown by commercial cargo aircraft to the airport at Yekaterinburg, Russia, and then transported by truck to the final destination in a secure nuclear facility at Chelyabinsk, Russia. This shipment of 23.7 kg of HEU was coordinated by the Russian Research Reactor Fuel Return Program (RRRFR), as part of the U.S. Department of Energy Global Threat Reduction Initiative (GTRI), in close cooperation with the Rosatom State Atomic Energy Corporation and the International Atomic Energy Agency, and was managed in Romania by the National Commission for Nuclear Activities Control (CNCAN). This paper describes the planning, shipment preparations, equipment design, and license approvals that resulted in the safe and secure air shipment of this spent nuclear fuel.« less

  18. Analysis of the TREAT LEU Conceptual Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connaway, H. M.; Kontogeorgakos, D. C.; Papadias, D. D.

    2016-03-01

    Analyses were performed to evaluate the performance of the low enriched uranium (LEU) conceptual design fuel for the conversion of the Transient Reactor Test Facility (TREAT) from its current highly enriched uranium (HEU) fuel. TREAT is an experimental nuclear reactor designed to produce high neutron flux transients for the testing of reactor fuels and other materials. TREAT is currently in non-operational standby, but is being restarted under the U.S. Department of Energy’s Resumption of Transient Testing Program. The conversion of TREAT is being pursued in keeping with the mission of the Department of Energy National Nuclear Security Administration’s Material Managementmore » and Minimization (M3) Reactor Conversion Program. The focus of this study was to demonstrate that the converted LEU core is capable of maintaining the performance of the existing HEU core, while continuing to operate safely. Neutronic and thermal hydraulic simulations have been performed to evaluate the performance of the LEU conceptual-design core under both steady-state and transient conditions, for both normal operation and reactivity insertion accident scenarios. In addition, ancillary safety analyses which were performed for previous LEU design concepts have been reviewed and updated as-needed, in order to evaluate if the converted LEU core will function safely with all existing facility systems. Simulations were also performed to evaluate the detailed behavior of the UO 2-graphite fuel, to support future fuel manufacturing decisions regarding particle size specifications. The results of these analyses will be used in conjunction with work being performed at Idaho National Laboratory and Los Alamos National Laboratory, in order to develop the Conceptual Design Report project deliverable.« less

  19. An investigation of reactivity effect due to inadvertent filling of the irradiation channels with water in NIRR-1 Nigeria Research Reactor-1.

    PubMed

    Iliyasu, U; Ibrahim, Y V; Umar, Sadiq; Agbo, S A; Jibrin, Y

    2017-05-01

    Investigation of reactivity variation due to flooding of the irradiation channels of Nigeria Research Reactor (NIRR-1) a low power miniature neutron source reactor (MNSR) located at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria Nigeria using the MCNP code for High Enrich Uranium (HEU) and Low Enrich Uranium (LEU) core has been simulated in this present study. In this work, the excess reactivity worth of flooding HEU core for 1 inner, 2 inner, 3 inner, 4 inner and all inner are 0.318mk, 0.577mk, 0.318mk, 1.204mk and 1.503mk respectively, and outer irradiation channels are 0.119mk, 0.169mk, 0.348mk, 0.438mk and 0.418mk respectively, the highest excess reactivity result from flooding both inner and outer irradiation channels is 2.04mk (±1.72×10 -7 ), the excess reactivity for LEU core was 0.299mk, 0.568mk, 0.896mk, 1.195mk and 1.524mk in the inner irradiation channels, and the outer irradiation channels are 0.129mk, 0.189mk, 0.219mk, 0.269mk and 0.548mk where the highest excess reactivity was 1.942mk (±1.64×10 -7 ) resulting from flooding inner and outer irradiation channels. The reactivity induced by flooding of the irradiation channels of NIRR-1 with water is within design safety limit enshrined in Safety Analysis Report of NIRR-1. The results also compare well with literature. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. 235U Holdup Measurements in Three 321-M Exhaust HEPA Banks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewberry, R

    2005-02-24

    The Analytical Development Section of Savannah River National Laboratory (SRNL) was requested by the Facilities Disposition Division to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. The 321-M facility was used to fabricate enriched uranium fuel assemblies, lithium-aluminum target tubes, neptunium assemblies, and miscellaneous components for the production reactors. The results of the holdup assays are essential for determining compliance with the Waste Acceptance Criteria, Material Control & Accountability, and to meet criticality safety controls. This report covers holdup measurements of uranium residue in three HEPA filter exhaustmore » banks of the 321-M facility. Each of the exhaust banks has dimensions near 7' x 14' x 4' and represents a complex holdup problem. A portable HPGe detector and EG&G Dart system that contains the high voltage power supply and signal processing electronics were used to determine highly enriched uranium (HEU) holdup. A personal computer with Gamma-Vision software was used to control the Dart MCA and to provide space to store and manipulate multiple 4096-channel {gamma}-ray spectra. Some acquisitions were performed with the portable detector configured to a Canberra Inspector using NDA2000 acquisition and analysis software. Our results for each component uses a mixture of redundant point source and area source acquisitions that yielded HEU contents in the range of 2-10 grams. This report discusses the methodology, non-destructive assay (NDA) measurements, assumptions, and results of the uranium holdup in these items. This report includes use of transmission-corrected assay as well as correction for contributions from secondary area sources.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dionne, B.; Tzanos, C. P.

    To support the safety analyses required for the conversion of the Belgian Reactor 2 (BR2) from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, the simulation of a number of loss-of-flow tests, with or without loss of pressure, has been undertaken. These tests were performed at BR2 in 1963 and used instrumented fuel assemblies (FAs) with thermocouples (TC) imbedded in the cladding as well as probes to measure the FAs power on the basis of their coolant temperature rise. The availability of experimental data for these tests offers an opportunity to better establish the credibility of the RELAP5-3D model andmore » methodology used in the conversion analysis. In order to support the HEU to LEU conversion safety analyses of the BR2 reactor, RELAP simulations of a number of loss-of-flow/loss-of-pressure tests have been undertaken. Preliminary analyses showed that the conservative power distributions used historically in the BR2 RELAP model resulted in a significant overestimation of the peak cladding temperature during the transient. Therefore, it was concluded that better estimates of the steady-state and decay power distributions were needed to accurately predict the cladding temperatures measured during the tests and establish the credibility of the RELAP model and methodology. The new approach ('best estimate' methodology) uses the MCNP5, ORIGEN-2 and BERYL codes to obtain steady-state and decay power distributions for the BR2 core during the tests A/400/1, C/600/3 and F/400/1. This methodology can be easily extended to simulate any BR2 core configuration. Comparisons with measured peak cladding temperatures showed a much better agreement when power distributions obtained with the new methodology are used.« less

  2. Dismantlement of the TSF-SNAP Reactor Assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peretz, Fred J

    2009-01-01

    This paper describes the dismantlement of the Tower Shielding Facility (TSF)?Systems for Nuclear Auxiliary Power (SNAP) reactor, a SNAP-10A reactor used to validate radiation source terms and shield performance models at Oak Ridge National Laboratory (ORNL) from 1967 through 1973. After shutdown, it was placed in storage at the Y-12 National Security Complex (Y-12), eventually falling under the auspices of the Highly Enriched Uranium (HEU) Disposition Program. To facilitate downblending of the HEU present in the fuel elements, the TSF-SNAP was moved to ORNL on June 24, 2006. The reactor assembly was removed from its packaging, inspected, and the sodium-potassiummore » (NaK) coolant was drained. A superheated steam process was used to chemically react the residual NaK inside the reactor assembly. The heat exchanger assembly was removed from the top of the reactor vessel, and the criticality safety sleeve was exchanged for a new safety sleeve that allowed for the removal of the vessel lid. A chain-mounted tubing cutter was used to separate the lid from the vessel, and the 36 fuel elements were removed and packaged in four U.S. Department of Transportation 2R/6M containers. The fuel elements were returned to Y-12 on July 13, 2006. The return of the fuel elements and disposal of all other reactor materials accomplished the formal objectives of the dismantlement project. In addition, a project model was established for the handling of a fully fueled liquid-metal?cooled reactor assembly. Current criticality safety codes have been benchmarked against experiments performed by Atomics International in the 1950s and 1960s. Execution of this project provides valuable experience applicable to future projects addressing space and liquid-metal-cooled reactors.« less

  3. Attributes from NMIS Time Coincidence, Fast-Neutron Imaging, Fission Mapping, And Gamma-Ray Spectrometry Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swift, Alicia L; Grogan, Brandon R; Mullens, James Allen

    This work tests a systematic procedure for analyzing data acquired by the Nuclear Materials Identification System (NMIS) at Oak Ridge National Laboratory with fast-neutron imaging and high-purity germanium (HPGe) gamma spectrometry capabilities. NMIS has been under development by the US Department of Energy Office of Nuclear Verification since the mid-1990s, and prior to that by the National Nuclear Security Administration Y-12 National Security Complex, with NMIS having been used at Y-12 for template matching to confirm inventory and receipts. In this present work, a complete set of NMIS time coincidence, fast-neutron imaging, fission mapping, and HPGe gamma-ray spectrometry data wasmore » obtained from Monte Carlo simulations for a configuration of fissile and nonfissile materials. The data were then presented for analysis to someone who had no prior knowledge of the unknown object to accurately determine the description of the object by applying the previously-mentioned procedure to the simulated data. The best approximation indicated that the unknown object was composed of concentric cylinders: a void inside highly enriched uranium (HEU) (84.7 {+-} 1.9 wt % {sup 235}U), surrounded by depleted uranium, surrounded by polyethylene. The final estimation of the unknown object had the correct materials and geometry, with error in the radius estimates of material regions varying from 1.58% at best and 4.25% at worst; error in the height estimates varied from 2% to 12%. The error in the HEU enrichment estimate was 5.9 wt % (within 2.5{sigma} of the true value). The accuracies of the determinations could be adequate for arms control applications. Future work will apply this iterative reconstructive procedure to other unknown objects to further test and refine it.« less

  4. Longitudinal development of cognitive, visuomotor and adaptive behavior skills in HIV uninfected children, aged 3-5 years of age, exposed pre- and perinatally to anti-retroviral medications.

    PubMed

    Smith, Mary Lou; Puka, Klajdi; Sehra, Ramandeep; Read, Stanley E; Bitnun, Ari

    2017-10-01

    Little is known about the neurodevelopmental outcomes of children older than 3 years of age born to HIV infected mother but who are HIV-uninfected (HEU), and who have been exposed in utero and early in life to HIV and to antiretroviral medications (ARVs). We conducted a longitudinal study of cognitive, visuomotor and adaptive function of HEU children, who were assessed at two ages, 3.5 and 5.5 years. Sixty-four children (33 female) were assessed. In comparison with population norms for their age, at 3.5 years of age they had scores significantly below age expectations on aspects of adaptive behavior, but at age 5.5 years, their scores did not significantly diverge from the population norms on any of the measures. Verbal intelligence was lower at age 5.5 than at age 3.5 years, although there were also improvements in some features of adaptive behavior. Exposure to PI-based ARVs (compared to NNRTIs) was associated with higher Performance IQ, visuomotor and communication scores at age 5.5 years. Birth, early growth, and sociodemographic variables were predictive of outcomes. This study is important in tracking the trajectory of neurocognitive development across the pre-school and early school age years. The findings suggest that the full impact of early ARV exposure may not be evident until a considerable period of development has occurred. The results raise the possibility of negative effects of early ARV exposure on neurodevelopment that emerge over time, and reiterate the importance of sociodemographic and early health variables for optimal development.

  5. Military Personnel: DOD Needs to Take Further Actions to Prevent Sexual Assault During Initial Military Training

    DTIC Science & Technology

    2014-09-01

    health care providers affected whether servicemembers who are victims of sexual assault can or do access mental health services. We made nine...victims’ access to mental health care ; and evaluate appropriate staffing levels of certain sexual assault response-related positions. DOD concurred with...Defense Health Care Reform: Additional Implementation Details Would Increase Transparency of DOD’s Plans and Enhance Accountability, GAO-14-49 (Washington

  6. Targeted Killing as an Element of U.S. Foreign Policy in the War On Terror

    DTIC Science & Technology

    2006-05-25

    terrorists. Given the level of secrecy and lack of transparency involved in this policy and its implementation, how can we judge the moral and legal ...killing’ morally justifiable and legal under both US domestic and international law? Can the United States maintain international legitimacy while...Rights Law and International Humanitarian Law to determine the legality of a policy of targeted killing. iii TABLE OF CONTENTS INTRODUCTION

  7. Web-Accessible Scientific Workflow System for Performance Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roelof Versteeg; Roelof Versteeg; Trevor Rowe

    2006-03-01

    We describe the design and implementation of a web accessible scientific workflow system for environmental monitoring. This workflow environment integrates distributed, automated data acquisition with server side data management and information visualization through flexible browser based data access tools. Component technologies include a rich browser-based client (using dynamic Javascript and HTML/CSS) for data selection, a back-end server which uses PHP for data processing, user management, and result delivery, and third party applications which are invoked by the back-end using webservices. This environment allows for reproducible, transparent result generation by a diverse user base. It has been implemented for several monitoringmore » systems with different degrees of complexity.« less

  8. All-fiber variable optical delay line for applications in optical coherence tomography: feasibility study for a novel delay line.

    PubMed

    Choi, Eunseo; Na, Jihoon; Ryu, Seon; Mudhana, Gopinath; Lee, Byeong

    2005-02-21

    We have implemented an all-fiber optical delay line using two linearly chirped fiber Bragg gratings cascaded in reverse order and all-fiber optics components. The features of the proposed all-fiber based technique for variable delay line are discussed theoretically and demonstrated experimentally. The non-invasive cross-sectional images of biomedical samples as well as a transparent glass plate obtained with implemented all-fiber delay line having the axial resolution of 100 mum and the dynamic range of 50dB are presented to validates the imaging performance and demonstrate the feasibility of the delay line for optical coherence tomography.

  9. 76 FR 1180 - FDA Transparency Initiative: Improving Transparency to Regulated Industry

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-07

    ...] FDA Transparency Initiative: Improving Transparency to Regulated Industry AGENCY: Food and Drug... the Transparency Initiative, the Food and Drug Administration (FDA) is announcing the availability of a report entitled ``FDA Transparency Initiative: Improving Transparency to Regulated Industry.'' The...

  10. A study of organizational versus individual needs related to recruitment, deployment and promotion of doctors working in the government health system in Odisha state, India.

    PubMed

    Kadam, Shridhar; Nallala, Srinivas; Zodpey, Sanjay; Pati, Sanghamitra; Hussain, Mohammad Akhtar; Chauhan, Abhimanyu Singh; Das, Sovesh; Martineau, Tim

    2016-02-24

    An effective health workforce is essential for achieving health-related new Sustainable Development Goals. Odisha, one of the states in India with low health indicators, faces challenges in recruiting and retaining health staff in the public sector, especially doctors. Recruitment, deployment and career progression play an important role in attracting and retaining doctors. We examined the policies on recruitment, deployment and promotion for doctors in the state and how these policies were perceived to be implemented. We undertook document review and four key informant interviews with senior state-level officials to delineate the policies for recruitment, deployment and promotion. We conducted 90 in-depth interviews, 86 with doctors from six districts and four at the state level to explore the perceptions of doctors about these policies. Despite the efforts by the Government of Odisha through regular recruitments, a quarter of the posts of doctors was vacant across all institutional levels in the state. The majority of doctors interviewed were unaware of existing government rules for placement, transfer and promotion. In addition, there were no explicit rules followed in placement and transfer. More than half (57%) of the doctors interviewed from well-accessible areas had never worked in the identified hard-to-reach areas in spite of having regulatory and incentive mechanisms. The average length of service before the first promotion was 26 (±3.5) years. The doctors expressed satisfaction with the recruitment process. They stated concerns over delayed first promotion, non-transparent deployment policies and ineffective incentive system. Almost all doctors suggested having time-bound and transparent policies. Adequate and appropriate deployment of doctors is a challenge for the government as it has to align the individual aspirations of employees with organizational needs. Explicit rules for human resource management coupled with transparency in implementation can improve governance and build trust among doctors which would encourage them to work in the public sector.

  11. Quasiparticle energies, excitonic effects, and dielectric screening in transparent conducting oxides

    NASA Astrophysics Data System (ADS)

    Schleife, André

    Using the power of high-performance super computers, computational materials scientists nowadays employ highly accurate quantum-mechanical approaches to reliably predict materials properties. In particular, many-body perturbation theory is an excellent framework for performing theoretical spectroscopy on novel materials including transparent conducting oxides, since this framework accurately describes quasiparticle and excitonic effects.We recently used hybrid exchange-correlation functionals and an efficient implementation of the Bethe-Salpeter approach to investigate several important transparent conducting oxides. Despite their exceptional potential for applications in photovoltaics and optoelectronics their optical properties oftentimes remain poorly understood: Our calculations explain the optical spectrum of bixbyite indium oxide over a very large photon energy range, which allows us to discuss the importance of quasiparticle and excitonic effects at low photon energies around the absorption onset, but also for excitations up to 40 eV. We show that in this regime the energy dependence of the electronic self energy cannot be neglected. Furthermore, we investigated the influence of excitonic effects on optical absorption for lanthanum-aluminum oxide and hafnium oxide. Their complicated conduction band structures require an accurate description of quasiparticle energies and we find that for these strongly polar materials, a contribution of the lattice polarizability to dielectric screening needs to be taken into account. We discuss how this affects the electron-hole interaction and find a strong influence on excitonic effects.The deep understanding of electronic excitations that can be obtained using these modern first-principles techniques, eventually will allow for computational materials design, e.g. of band gaps, densities of states, and optical properties of transparent conducting oxides and other materials with societally important applications.

  12. Critical issues related to registration of space objects and transparency of space activities

    NASA Astrophysics Data System (ADS)

    Jakhu, Ram S.; Jasani, Bhupendra; McDowell, Jonathan C.

    2018-02-01

    The main purpose of the 1975 Registration Convention is to achieve transparency in space activities and this objective is motivated by the belief that a mandatory registration system would assist in the identification of space objects launched into outer space. This would also consequently contribute to the application and development of international law governing the exploration and use of outer space. States Parties to the Convention furnish the required information to the United Nations' Register of Space Objects. However, the furnished information is often so general that it may not be as helpful in creating transparency as had been hoped by the drafters of the Convention. While registration of civil satellites has been furnished with some general details, till today, none of the Parties have described the objects as having military functions despite the fact that a large number of such objects do perform military functions as well. In some cases, the best they have done is to indicate that the space objects are for their defense establishments. Moreover, the number of registrations of space objects is declining. This paper addresses the challenges posed by the non-registration of space objects. Particularly, the paper provides some data about the registration and non-registration of satellites and the States that have and have not complied with their legal obligations. It also analyses the specific requirements of the Convention, the reasons for non-registration, new challenges posed by the registration of small satellites and the on-orbit transfer of satellites. Finally, the paper provides some recommendations on how to enhance the registration of space objects, on the monitoring of the implementation of the Registration Convention and consequently how to achieve maximum transparency in space activities.

  13. The role of opacity and transparency in achieving strategic stability in South Asia.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rajain, Arpit; Ashraf, Tariq Mahmud

    According to international relations theory, deterrence can be used as a tool to achieve stability between potentially hostile nations. India and Pakistan's long history of periodic crises raises the question of how they can achieve deterrence stability. 'Transparency' describes the flow of information between parties and plays a key role in establishing a deterrence relationship. This paper studies the balance needed between opacity and transparency in nuclear topics for the maintenance of deterrence stability between India and Pakistan. States with nuclear weapons are postulated to implement transparency in four categories: potential, capability, intent, and resolve. The study applies these categoriesmore » to the nuclear components of the ongoing India-Pakistan Composite Dialogue Working Group for Peace and Security including CBMs. To focus our efforts, we defined four scenarios to characterize representative strategic/military/political conditions. The scenarios are combinations of these two sets of opposite poles: competition - cooperation; extremism - moderation (to be understood primarily in a religious/nationalistic sense). We describe each scenario in terms of select focal areas (nuclear doctrine, nuclear command and control, nuclear stockpile, nuclear delivery/defensive systems, and conventional force posture). The scenarios help frame the realm of possibilities, and have been described in terms of expected conditions for the focal areas. We then use the conditions in each scenario to prescribe a range of information-sharing actions that the two countries could take to increase stability. We also highlight the information that should not be shared. These actions can be political (e.g., declarations), procedural (e.g., advance notice of certain military activities), or technologically based (e.g., seismic monitoring of the nuclear test moratorium).« less

  14. Proliferation of gynaecological scientific societies and their financial transparency: an Italian survey

    PubMed Central

    Vercellini, Paolo; Viganò, Paola; Frattaruolo, Maria Pina; Somigliana, Edgardo

    2016-01-01

    Objectives To determine the number of Italian obstetrical and gynaecological societies, and to ascertain their financial transparency. Design Internet-based national survey and website content analysis. Participants Currently active, not privately owned, non-religious, apolitical, obstetrical and gynaecological associations. Methods From October 2014 to June 2015, scientific societies were identified using combinations of search terms, and examining the website of the two main Italian obstetrical and gynaecological organisations. Individual societies’ websites were scrutinised by two independent investigators. Primary and secondary outcome measures Number of Italian obstetrical and gynaecological associations and its variation over time; 12 information categories defining the general characteristics of the societies and their websites, and the financial transparency of the associations. Results The initial web search yielded 56 professional obstetrical and gynaecological associations but nine were excluded for various reasons. Of the remaining 47 professional associations, 17 covered both obstetrics and gynaecology, four were specialised in obstetrics, 26 in gynaecology and 46 provided continuing medical education (CME) activities. The number of societies has quadrupled in the last 35 years, increasing at a mean rate of one additional society per year. The headquarters of the associations were located in the offices of a professional congress organiser in 15 instances, and advertisements or links to industry products were present in 12 societies’ websites. Bylaws were accessible in 32 websites. No information was publicly available regarding competing interests, financial statements and quantitative external funding. Conclusions The number of obstetrical and gynaecological societies is remarkably high in Italy, particularly in the gynaecological area. Despite CME activity provision, transparency of societies regarding financial issues and competing interests was almost non-existent. Policies addressing the interactions between medical associations and industry are available and should be implemented. PMID:26769777

  15. Detection and Purging of Specular Reflective and Transparent Object Influences in 3d Range Measurements

    NASA Astrophysics Data System (ADS)

    Koch, R.; May, S.; Nüchter, A.

    2017-02-01

    3D laser scanners are favoured sensors for mapping in mobile service robotics at indoor and outdoor applications, since they deliver precise measurements at a wide scanning range. The resulting maps are detailed since they have a high resolution. Based on these maps robots navigate through rough terrain, fulfil advanced manipulation, and inspection tasks. In case of specular reflective and transparent objects, e.g., mirrors, windows, shiny metals, the laser measurements get corrupted. Based on the type of object and the incident angle of the incoming laser beam there are three results possible: a measurement point on the object plane, a measurement behind the object plane, and a measurement of a reflected object. It is important to detect such situations to be able to handle these corrupted points. This paper describes why it is difficult to distinguish between specular reflective and transparent surfaces. It presents a 3DReflection- Pre-Filter Approach to identify specular reflective and transparent objects in point clouds of a multi-echo laser scanner. Furthermore, it filters point clouds from influences of such objects and extract the object properties for further investigations. Based on an Iterative-Closest-Point-algorithm reflective objects are identified. Object surfaces and points behind surfaces are masked according to their location. Finally, the processed point cloud is forwarded to a mapping module. Furthermore, the object surface corners and the type of the surface is broadcasted. Four experiments demonstrate the usability of the 3D-Reflection-Pre-Filter. The first experiment was made in a empty room containing a mirror, the second experiment was made in a stairway containing a glass door, the third experiment was made in a empty room containing two mirrors, the fourth experiment was made in an office room containing a mirror. This paper demonstrate that for single scans the detection of specular reflective and transparent objects in 3D is possible. It is more reliable in 3D as in 2D. Nevertheless, collect the data of multiple scans and post-filter them as soon as the object was bypassed should pursued. This is why future work concentrates on implementing a post-filter module. Besides, it is the aim to improve the discrimination between specular reflective and transparent objects.

  16. Digital technology for health sector governance in low and middle income countries: a scoping review

    PubMed Central

    Holeman, Isaac; Cookson, Tara Patricia; Pagliari, Claudia

    2016-01-01

    Background Poor governance impedes the provision of equitable and cost–effective health care in many low– and middle–income countries (LMICs). Although systemic problems such as corruption and inefficiency have been characterized as intractable, “good governance” interventions that promote transparency, accountability and public participation have yielded encouraging results. Mobile phones and other Information and Communication Technologies (ICTs) are beginning to play a role in these interventions, but little is known about their use and effects in the context of LMIC health care. Methods Multi–stage scoping review: Research questions and scope were refined through a landscape scan of relevant implementation activities and by analyzing related concepts in the literature. Relevant studies were identified through iterative Internet searches (Google, Google Scholar), a systematic search of academic databases (PubMed, Web of Science), social media crowdsourcing (targeted LinkedIn and Twitter appeals) and reading reference lists and websites of relevant organizations. Parallel expert interviews helped to verify concepts and emerging findings and identified additional studies for inclusion. Results were charted, analyzed thematically and summarized. Results We identified 34 articles from a wide range of disciplines and sectors, including 17 published research articles and 17 grey literature reports. Analysis of these articles revealed 15 distinct ways of using ICTs for good governance activities in LMIC health care. These use cases clustered into four conceptual categories: 1) gathering and verifying information on services to improve transparency and auditability 2) aggregating and visualizing data to aid communication and decision making 3) mobilizing citizens in reporting poor practices to improve accountability and quality and 4) automating and auditing processes to prevent fraud. Despite a considerable amount of implementation activity, we identified little formal evaluative research. Conclusion Innovative digital approaches are increasingly being used to facilitate good governance in the health sectors of LMICs but evidence of their effectiveness is still limited. More empirical studies are needed to measure concrete impacts, document mechanisms of action, and elucidate the political and sociotechnical dynamics that make designing and implementing ICTs for good governance so complex. Many digital good governance interventions are driven by an assumption that transparency alone will effect change; however responsive feedback mechanisms are also likely to be necessary. PMID:27648255

  17. How Are New Vaccines Prioritized in Low-Income Countries? A Case Study of Human Papilloma Virus Vaccine and Pneumococcal Conjugate Vaccine in Uganda.

    PubMed

    Wallace, Lauren; Kapirir, Lydia

    2017-04-08

    To date, research on priority-setting for new vaccines has not adequately explored the influence of the global, national and sub-national levels of decision-making or contextual issues such as political pressure and stakeholder influence and power. Using Kapiriri and Martin's conceptual framework, this paper evaluates priority setting for new vaccines in Uganda at national and sub-national levels, and considers how global priorities can influence country priorities. This study focuses on 2 specific vaccines, the human papilloma virus (HPV) vaccine and the pneumococcal conjugate vaccine (PCV). This was a qualitative study that involved reviewing relevant Ugandan policy documents and media reports, as well as 54 key informant interviews at the global level and national and sub-national levels in Uganda. Kapiriri and Martin's conceptual framework was used to evaluate the prioritization process. Priority setting for PCV and HPV was conducted by the Ministry of Health (MoH), which is considered to be a legitimate institution. While respondents described the priority setting process for PCV process as transparent, participatory, and guided by explicit relevant criteria and evidence, the prioritization of HPV was thought to have been less transparent and less participatory. Respondents reported that neither process was based on an explicit priority setting framework nor did it involve adequate representation from the districts (program implementers) or publicity. The priority setting process for both PCV and HPV was negatively affected by the larger political and economic context, which contributed to weak institutional capacity as well as power imbalances between development assistance partners and the MoH. Priority setting in Uganda would be improved by strengthening institutional capacity and leadership and ensuring a transparent and participatory processes in which key stakeholders such as program implementers (the districts) and beneficiaries (the public) are involved. Kapiriri and Martin's framework has the potential to guide priority setting evaluation efforts, however, evaluation should be built into the priority setting process a priori such that information on priority setting is gathered throughout the implementation cycle. © 2017 The Author(s); Published by Kerman University of Medical Sciences. This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  18. Cochrane Qualitative and Implementation Methods Group guidance series-paper 6: reporting guidelines for qualitative, implementation, and process evaluation evidence syntheses.

    PubMed

    Flemming, Kate; Booth, Andrew; Hannes, Karin; Cargo, Margaret; Noyes, Jane

    2018-05-01

    To outline contemporary and novel developments for the presentation and reporting of syntheses of qualitative, implementation, and process evaluation evidence and provide recommendations for the use of reporting guidelines. An overview of reporting guidelines for qualitative, implementation, and process evaluation evidence syntheses drawing on current international literature and the collective expert knowledge of the Cochrane Qualitative and Implementation Methods Group. Several reporting guidelines exist that can be used or adapted to report syntheses of qualitative, implementation, and process evaluation evidence. Methods to develop individual guidance varied. The use of a relevant reporting guideline can enhance the transparency, consistency, and quality of reporting. Guidelines that exist are generic, method specific, and for particular aspects of the reviewing process, searching. Caution is expressed over the potential for reporting guidelines to produce a mechanistic approach moving the focus away from the content and toward the procedural aspects of the review. The use of a reporting guideline is recommended and a five-step decision flowchart to guide the choice of reporting guideline is provided. Gaps remain in method-specific reporting guidelines such as mixed-study, implementation, and process evaluation evidence syntheses. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Method of forming macro-structured high surface area transparent conductive oxide electrodes

    DOEpatents

    Forman, Arnold J.; Chen, Zhebo; Jaramillo, Thomas F.

    2016-01-05

    A method of forming a high surface area transparent conducting electrode is provided that includes depositing a transparent conducting thin film on a conductive substrate, where the transparent conducting thin film includes transparent conductive particles and a solution-based transparent conducting adhesive layer which serves to coat and bind together the transparent conducting particles, and heat treating the transparent conducting adhesion layer on the conductive substrate, where an increased surface area transparent conducting electrode is formed.

  20. Comparison Of A Neutron Kinetics Parameter For A Polyethylene Moderated Highly Enriched Uranium System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenzie, IV, George Espy; Goda, Joetta Marie; Grove, Travis Justin

    This paper examines the comparison of MCNP® code’s capability to calculate kinetics parameters effectively for a thermal system containing highly enriched uranium (HEU). The Rossi-α parameter was chosen for this examination because it is relatively easy to measure as well as easy to calculate using MCNP®’s kopts card. The Rossi-α also incorporates many other parameters of interest in nuclear kinetics most of which are more difficult to precisely measure. The comparison looks at two different nuclear data libraries for comparison to the experimental data. These libraries are ENDF/BVI (.66c) and ENDF/BVII (.80c).

  1. Interim Report on Mixing During the Casting of LEU-10Mo Plates in the Triple Plate Molds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aikin, Jr., Robert M.

    LEU-10%Mo castings are commonly produced by down blending unalloyed HEU with a DU-12.7%Mo master-alloy. This work uses process modeling to provide insight into the mixing of the unalloyed uranium and U-Mo master alloy during melting and mold filling of a triple plate casting. Two different sets of situations are considered: (1) mixing during mold filling from a compositionally stratified crucible and (2) convective mixing of a compositionally stratified crucible during mold heating. The mold filling simulations are performed on the original Y-12 triple plate mold and the horizontal triple plate mold.

  2. NSLS-II BPM System Protection from Rogue Mode Coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blednykh, A.; Bach, B.; Borrelli, A.

    2011-03-28

    Rogue mode RF shielding has been successfully designed and implemented into the production multipole vacuum chambers. In order to avoid systematic errors in the NSLS-II BPM system we introduced frequency shift of HOM's by using RF metal shielding located in the antechamber slot of each multipole vacuum chamber. To satisfy the pumping requirement the face of the shielding has been perforated with roughly 50 percent transparency. It stays clear of synchrotron radiation in each chamber.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haynes, R.A.

    The Network File System (NFS) is used in UNIX-based networks to provide transparent file sharing between heterogeneous systems. Although NFS is well-known for being weak in security, it is widely used and has become a de facto standard. This paper examines the user authentication shortcomings of NFS and the approach Sandia National Laboratories has taken to strengthen it with Kerberos. The implementation on a Cray Y-MP8/864 running UNICOS is described and resource/performance issues are discussed. 4 refs., 4 figs.

  4. Recovery Act: Increasing the Public's Understanding of What Funds Are Being Spent on and What Outcomes Are Expected. Report to the Republican Leader, U.S. Senate. GAO-10-581

    ERIC Educational Resources Information Center

    US Government Accountability Office, 2010

    2010-01-01

    A hallmark of efforts to implement the $862 billion American Recovery and Reinvestment Act of 2009 (Recovery Act) is to be transparent and accountable about what the money is being spent on and what is being achieved. To help achieve these goals, recipients are to report every 3 months on their award activities and expected outcomes, among other…

  5. AliEn—ALICE environment on the GRID

    NASA Astrophysics Data System (ADS)

    Saiz, P.; Aphecetche, L.; Bunčić, P.; Piskač, R.; Revsbech, J.-E.; Šego, V.; Alice Collaboration

    2003-04-01

    AliEn ( http://alien.cern.ch) (ALICE Environment) is a Grid framework built on top of the latest Internet standards for information exchange and authentication (SOAP, PKI) and common Open Source components. AliEn provides a virtual file catalogue that allows transparent access to distributed datasets and a number of collaborating Web services which implement the authentication, job execution, file transport, performance monitor and event logging. In the paper we will present the architecture and components of the system.

  6. e-Government for Development Information Exchange (DIE): Zambia

    NASA Astrophysics Data System (ADS)

    Joseph, Bwalya Kelvin

    In most parts of the world, political systems which utilize authoritative rule and mostly employ top-down decision-making processes are slowly transcending towards democratic norms. Information Technology Systems have been identified and adopted as one of the most efficient vehicles for appropriate, transparent and inclusive / participatory decision making. Zambia has shown a higher propensity to indigenous knowledge systems which are full of inefficiencies, a lot of red tape in public service delivery, and prone to corrupt practices. Despite that being the case, it is slowly trying to implement e-government. The adoption of e-government promises a sharp paradigm shift where public institutions will be more responsive and transparent, promote efficient PPP (Public Private Partnerships), and empower citizens by making knowledge and other resources more directly accessible. This paper examines three cases from Zambia where ICT in support of e-government has been implemented for Development Information Exchange (DIE) - knowledge-based decision making. The paper also assesses the challenges, opportunities, and issues together with e-government adoption criteria regarding successful encapsulation of e-government into the Zambian contextual environment. I propose a conceptual model which offers balanced e-government adoption criteria involving a combination of electronic and participatory services. This conceptual e-government adoption model can later be replicated to be used at the Southern African Development Community (SADC) level given the similarity in the contextual environment.

  7. Translating research findings to clinical nursing practice.

    PubMed

    Curtis, Kate; Fry, Margaret; Shaban, Ramon Z; Considine, Julie

    2017-03-01

    To describe the importance of, and methods for, successfully conducting and translating research into clinical practice. There is universal acknowledgement that the clinical care provided to individuals should be informed on the best available evidence. Knowledge and evidence derived from robust scholarly methods should drive our clinical practice, decisions and change to improve the way we deliver care. Translating research evidence to clinical practice is essential to safe, transparent, effective and efficient healthcare provision and meeting the expectations of patients, families and society. Despite its importance, translating research into clinical practice is challenging. There are more nurses in the frontline of health care than any other healthcare profession. As such, nurse-led research is increasingly recognised as a critical pathway to practical and effective ways of improving patient outcomes. However, there are well-established barriers to the conduct and translation of research evidence into practice. This clinical practice discussion paper interprets the knowledge translation literature for clinicians interested in translating research into practice. This paper is informed by the scientific literature around knowledge translation, implementation science and clinician behaviour change, and presented from the nurse clinician perspective. We provide practical, evidence-informed suggestions to overcome the barriers and facilitate enablers of knowledge translation. Examples of nurse-led research incorporating the principles of knowledge translation in their study design that have resulted in improvements in patient outcomes are presented in conjunction with supporting evidence. Translation should be considered in research design, including the end users and an evaluation of the research implementation. The success of research implementation in health care is dependent on clinician/consumer behaviour change and it is critical that implementation strategy includes this. Translating best research evidence can make for a more transparent and sustainable healthcare service, to which nurses are central. © 2016 The Authors. Journal of Clinical Nursing Published by John Wiley & Sons Ltd.

  8. A web-based information system for a regional public mental healthcare service network in Brazil.

    PubMed

    Yoshiura, Vinicius Tohoru; de Azevedo-Marques, João Mazzoncini; Rzewuska, Magdalena; Vinci, André Luiz Teixeira; Sasso, Ariane Morassi; Miyoshi, Newton Shydeo Brandão; Furegato, Antonia Regina Ferreira; Rijo, Rui Pedro Charters Lopes; Del-Ben, Cristina Marta; Alves, Domingos

    2017-01-01

    Regional networking between services that provide mental health care in Brazil's decentralized public health system is challenging, partly due to the simultaneous existence of services managed by municipal and state authorities and a lack of efficient and transparent mechanisms for continuous and updated communication between them. Since 2011, the Ribeirao Preto Medical School and the XIII Regional Health Department of the Sao Paulo state, Brazil, have been developing and implementing a web-based information system to facilitate an integrated care throughout a public regional mental health care network. After a profound on-site analysis, the structure of the network was identified and a web-based information system for psychiatric admissions and discharges was developed and implemented using a socio-technical approach. An information technology team liaised with mental health professionals, health-service managers, municipal and state health secretariats and judicial authorities. Primary care, specialized community services, general emergency and psychiatric wards services, that comprise the regional mental healthcare network, were identified and the system flow was delineated. The web-based system overcame the fragmentation of the healthcare system and addressed service specific needs, enabling: detailed patient information sharing; active coordination of the processes of psychiatric admissions and discharges; real-time monitoring; the patients' status reports; the evaluation of the performance of each service and the whole network. During a 2-year period of operation, it registered 137 services, 480 health care professionals and 4271 patients, with a mean number of 2835 accesses per month. To date the system is successfully operating and further expanding. We have successfully developed and implemented an acceptable, useful and transparent web-based information system for a regional mental healthcare service network in a medium-income country with a decentralized public health system. Systematic collaboration between an information technology team and a wide range of stakeholders is essential for the system development and implementation.

  9. Real-time implementation of second generation of audio multilevel information coding

    NASA Astrophysics Data System (ADS)

    Ali, Murtaza; Tewfik, Ahmed H.; Viswanathan, V.

    1994-03-01

    This paper describes real-time implementation of a novel wavelet- based audio compression method. This method is based on the discrete wavelet (DWT) representation of signals. A bit allocation procedure is used to allocate bits to the transform coefficients in an adaptive fashion. The bit allocation procedure has been designed to take advantage of the masking effect in human hearing. The procedure minimizes the number of bits required to represent each frame of audio signals at a fixed distortion level. The real-time implementation provides almost transparent compression of monophonic CD quality audio signals (samples at 44.1 KHz and quantized using 16 bits/sample) at bit rates of 64-78 Kbits/sec. Our implementation uses two ASPI Elf boards, each of which is built around a TI TMS230C31 DSP chip. The time required for encoding of a mono CD signal is about 92 percent of real time and that for decoding about 61 percent.

  10. A Fully Transparent Flexible Sensor for Cryogenic Temperatures Based on High Strength Metallurgical Graphene

    PubMed Central

    Pawlak, Ryszard; Lebioda, Marcin; Rymaszewski, Jacek; Szymanski, Witold; Kolodziejczyk, Lukasz; Kula, Piotr

    2016-01-01

    Low-temperature electronics operating in below zero temperatures or even below the lower limit of the common −65 to 125 °C temperature range are essential in medical diagnostics, in space exploration and aviation, in processing and storage of food and mainly in scientific research, like superconducting materials engineering and their applications—superconducting magnets, superconducting energy storage, and magnetic levitation systems. Such electronic devices demand special approach to the materials used in passive elements and sensors. The main goal of this work was the implementation of a fully transparent, flexible cryogenic temperature sensor with graphene structures as sensing element. Electrodes were made of transparent ITO (Indium Tin Oxide) or ITO/Ag/ITO conductive layers by laser ablation and finally encapsulated in a polymer coating. A helium closed-cycle cryostat has been used in measurements of the electrical properties of these graphene-based temperature sensors under cryogenic conditions. The sensors were repeatedly cooled from room temperature to cryogenic temperature. Graphene structures were characterized using Raman spectroscopy. The observation of the resistance changes as a function of temperature indicates the potential use of graphene layers in the construction of temperature sensors. The temperature characteristics of the analyzed graphene sensors exhibit no clear anomalies or strong non-linearity in the entire studied temperature range (as compared to the typical carbon sensor). PMID:28036036

  11. Flexible electronics-compatible non-enzymatic glucose sensing via transparent CuO nanowire networks on PET films

    NASA Astrophysics Data System (ADS)

    Bell, Caroline; Nammari, Abdullah; Uttamchandani, Pranay; Rai, Amit; Shah, Pujan; Moore, Arden L.

    2017-06-01

    Diabetic individuals need simple, accurate, and cost effective means by which to independently assess their glucose levels in a non-invasive way. In this work, a sensor based on randomly oriented CuO nanowire networks supported by a polyethylene terephthalate thin film is evaluated as a flexible, transparent, non-enzymatic glucose sensing system analogous to those envisioned for future wearable diagnostic devices. The amperometric sensing characteristics of this type of device architecture are evaluated both before and after bending, with the system’s glucose response, sensitivity, lower limit of detection, and effect of applied bias being experimentally determined. The obtained data shows that the sensor is capable of measuring changes in glucose levels within a physiologically relevant range (0-12 mM glucose) and at lower limits of detection (0.05 mM glucose at +0.6 V bias) consistent with patient tears and saliva. Unlike existing studies utilizing a conductive backing layer or macroscopic electrode setup, this sensor demonstrates a percolation network-like trend of current versus glucose concentration. In this implementation, controlling the architectural details of the CuO nanowire network could conceivably allow the sensor’s sensitivity and optimal sensing range to be tuned. Overall, this work shows that integrating CuO nanowires into a sensor architecture compatible with transparent, flexible electronics is a promising avenue to realizing next generation wearable non-enzymatic glucose diagnostic devices.

  12. A Fully Transparent Flexible Sensor for Cryogenic Temperatures Based on High Strength Metallurgical Graphene.

    PubMed

    Pawlak, Ryszard; Lebioda, Marcin; Rymaszewski, Jacek; Szymanski, Witold; Kolodziejczyk, Lukasz; Kula, Piotr

    2016-12-28

    Low-temperature electronics operating in below zero temperatures or even below the lower limit of the common -65 to 125 °C temperature range are essential in medical diagnostics, in space exploration and aviation, in processing and storage of food and mainly in scientific research, like superconducting materials engineering and their applications-superconducting magnets, superconducting energy storage, and magnetic levitation systems. Such electronic devices demand special approach to the materials used in passive elements and sensors. The main goal of this work was the implementation of a fully transparent, flexible cryogenic temperature sensor with graphene structures as sensing element. Electrodes were made of transparent ITO (Indium Tin Oxide) or ITO/Ag/ITO conductive layers by laser ablation and finally encapsulated in a polymer coating. A helium closed-cycle cryostat has been used in measurements of the electrical properties of these graphene-based temperature sensors under cryogenic conditions. The sensors were repeatedly cooled from room temperature to cryogenic temperature. Graphene structures were characterized using Raman spectroscopy. The observation of the resistance changes as a function of temperature indicates the potential use of graphene layers in the construction of temperature sensors. The temperature characteristics of the analyzed graphene sensors exhibit no clear anomalies or strong non-linearity in the entire studied temperature range (as compared to the typical carbon sensor).

  13. Human resource governance: what does governance mean for the health workforce in low- and middle-income countries?

    PubMed

    Kaplan, Avril D; Dominis, Sarah; Palen, John Gh; Quain, Estelle E

    2013-02-15

    Research on practical and effective governance of the health workforce is limited. This paper examines health system strengthening as it occurs in the intersection between the health workforce and governance by presenting a framework to examine health workforce issues related to eight governance principles: strategic vision, accountability, transparency, information, efficiency, equity/fairness, responsiveness and citizen voice and participation. This study builds off of a literature review that informed the development of a framework that describes linkages and assigns indicators between governance and the health workforce. A qualitative analysis of Health System Assessment (HSA) data, a rapid indicator-based methodology that determines the key strengths and weaknesses of a health system using a set of internationally recognized indicators, was completed to determine how 20 low- and middle-income countries are operationalizing health governance to improve health workforce performance. The 20 countries assessed showed mixed progress in implementing the eight governance principles. Strengths highlighted include increasing the transparency of financial flows from sources to providers by implementing and institutionalizing the National Health Accounts methodology; increasing responsiveness to population health needs by training new cadres of health workers to address shortages and deliver care to remote and rural populations; having structures in place to register and provide licensure to medical professionals upon entry into the public sector; and implementing pilot programs that apply financial and non-financial incentives as a means to increase efficiency. Common weaknesses emerging in the HSAs include difficulties with developing, implementing and evaluating health workforce policies that outline a strategic vision for the health workforce; implementing continuous licensure and regulation systems to hold health workers accountable after they enter the workforce; and making use of health information systems to acquire data from providers and deliver it to policymakers. The breadth of challenges facing the health workforce requires strengthening health governance as well as human resource systems in order to effect change in the health system. Further research into the effectiveness of specific interventions that enhance the link between the health workforce and governance are warranted to determine approaches to strengthening the health system.

  14. Human resource governance: what does governance mean for the health workforce in low- and middle-income countries?

    PubMed Central

    2013-01-01

    Background Research on practical and effective governance of the health workforce is limited. This paper examines health system strengthening as it occurs in the intersection between the health workforce and governance by presenting a framework to examine health workforce issues related to eight governance principles: strategic vision, accountability, transparency, information, efficiency, equity/fairness, responsiveness and citizen voice and participation. Methods This study builds off of a literature review that informed the development of a framework that describes linkages and assigns indicators between governance and the health workforce. A qualitative analysis of Health System Assessment (HSA) data, a rapid indicator-based methodology that determines the key strengths and weaknesses of a health system using a set of internationally recognized indicators, was completed to determine how 20 low- and middle-income countries are operationalizing health governance to improve health workforce performance. Results/discussion The 20 countries assessed showed mixed progress in implementing the eight governance principles. Strengths highlighted include increasing the transparency of financial flows from sources to providers by implementing and institutionalizing the National Health Accounts methodology; increasing responsiveness to population health needs by training new cadres of health workers to address shortages and deliver care to remote and rural populations; having structures in place to register and provide licensure to medical professionals upon entry into the public sector; and implementing pilot programs that apply financial and non-financial incentives as a means to increase efficiency. Common weaknesses emerging in the HSAs include difficulties with developing, implementing and evaluating health workforce policies that outline a strategic vision for the health workforce; implementing continuous licensure and regulation systems to hold health workers accountable after they enter the workforce; and making use of health information systems to acquire data from providers and deliver it to policymakers. Conclusions The breadth of challenges facing the health workforce requires strengthening health governance as well as human resource systems in order to effect change in the health system. Further research into the effectiveness of specific interventions that enhance the link between the health workforce and governance are warranted to determine approaches to strengthening the health system. PMID:23414237

  15. Implementation of the Single European Code in a Multi-Tissue Bank.

    PubMed

    Schroeter, Jan; Schulz, Tino; Schroeter, Bernard; Fleischhauer, Katrin; Pruß, Axel

    2017-11-01

    The traceability of tissue and cells transplants is important to ensure a high level of safety for the recipients. With the final introduction of the Single European Code (SEC) in April 2017 in the EU a consistent system among all member states became mandatory. The regulations for the SEC on EU and national level were evaluated. An overview on the different parts of the SEC with detailed explanations is given. Our own experiences with the implementation of the SEC in our multi-tissue bank are reported in addition. The implementation of the SEC in our multi-tissue bank could be successfully realized. However, it revealed a number of difficulties, especially the sterile labeling of certain tissue transplants and the complex update of the existing database. The introduction of the SEC has made a contribution to the safety of recipients of tissue and cells transplants through a system of comprehensive and transparent traceability.

  16. Implementing real-time robotic systems using CHIMERA II

    NASA Technical Reports Server (NTRS)

    Stewart, David B.; Schmitz, Donald E.; Khosla, Pradeep K.

    1990-01-01

    A description is given of the CHIMERA II programming environment and operating system, which was developed for implementing real-time robotic systems. Sensor-based robotic systems contain both general- and special-purpose hardware, and thus the development of applications tends to be a time-consuming task. The CHIMERA II environment is designed to reduce the development time by providing a convenient software interface between the hardware and the user. CHIMERA II supports flexible hardware configurations which are based on one or more VME-backplanes. All communication across multiple processors is transparent to the user through an extensive set of interprocessor communication primitives. CHIMERA II also provides a high-performance real-time kernel which supports both deadline and highest-priority-first scheduling. The flexibility of CHIMERA II allows hierarchical models for robot control, such as NASREM, to be implemented with minimal programming time and effort.

  17. Performance Analysis of Ivshmem for High-Performance Computing in Virtual Machines

    NASA Astrophysics Data System (ADS)

    Ivanovic, Pavle; Richter, Harald

    2018-01-01

    High-Performance computing (HPC) is rarely accomplished via virtual machines (VMs). In this paper, we present a remake of ivshmem which can change this. Ivshmem was a shared memory (SHM) between virtual machines on the same server, with SHM-access synchronization included, until about 5 years ago when newer versions of Linux and its virtualization library libvirt evolved. We restored that SHM-access synchronization feature because it is indispensable for HPC and made ivshmem runnable with contemporary versions of Linux, libvirt, KVM, QEMU and especially MPICH, which is an implementation of MPI - the standard HPC communication library. Additionally, MPICH was transparently modified by us to get ivshmem included, resulting in a three to ten times performance improvement compared to TCP/IP. Furthermore, we have transparently replaced MPI_PUT, a single-side MPICH communication mechanism, by an own MPI_PUT wrapper. As a result, our ivshmem even surpasses non-virtualized SHM data transfers for block lengths greater than 512 KBytes, showing the benefits of virtualization. All improvements were possible without using SR-IOV.

  18. Chromatic confocal microscopy for multi-depth imaging of epithelial tissue

    PubMed Central

    Olsovsky, Cory; Shelton, Ryan; Carrasco-Zevallos, Oscar; Applegate, Brian E.; Maitland, Kristen C.

    2013-01-01

    We present a novel chromatic confocal microscope capable of volumetric reflectance imaging of microstructure in non-transparent tissue. Our design takes advantage of the chromatic aberration of aspheric lenses that are otherwise well corrected. Strong chromatic aberration, generated by multiple aspheres, longitudinally disperses supercontinuum light onto the sample. The backscattered light detected with a spectrometer is therefore wavelength encoded and each spectrum corresponds to a line image. This approach obviates the need for traditional axial mechanical scanning techniques that are difficult to implement for endoscopy and susceptible to motion artifact. A wavelength range of 590-775 nm yielded a >150 µm imaging depth with ~3 µm axial resolution. The system was further demonstrated by capturing volumetric images of buccal mucosa. We believe these represent the first microstructural images in non-transparent biological tissue using chromatic confocal microscopy that exhibit long imaging depth while maintaining acceptable resolution for resolving cell morphology. Miniaturization of this optical system could bring enhanced speed and accuracy to endomicroscopic in vivo volumetric imaging of epithelial tissue. PMID:23667789

  19. Algorithm-Based Fault Tolerance for Numerical Subroutines

    NASA Technical Reports Server (NTRS)

    Tumon, Michael; Granat, Robert; Lou, John

    2007-01-01

    A software library implements a new methodology of detecting faults in numerical subroutines, thus enabling application programs that contain the subroutines to recover transparently from single-event upsets. The software library in question is fault-detecting middleware that is wrapped around the numericalsubroutines. Conventional serial versions (based on LAPACK and FFTW) and a parallel version (based on ScaLAPACK) exist. The source code of the application program that contains the numerical subroutines is not modified, and the middleware is transparent to the user. The methodology used is a type of algorithm- based fault tolerance (ABFT). In ABFT, a checksum is computed before a computation and compared with the checksum of the computational result; an error is declared if the difference between the checksums exceeds some threshold. Novel normalization methods are used in the checksum comparison to ensure correct fault detections independent of algorithm inputs. In tests of this software reported in the peer-reviewed literature, this library was shown to enable detection of 99.9 percent of significant faults while generating no false alarms.

  20. Transparent process migration: Design alternatives and the Sprite implementation

    NASA Technical Reports Server (NTRS)

    Douglis, Fred; Ousterhout, John

    1991-01-01

    The Sprite operating system allows executing processes to be moved between hosts at any time. We use this process migration mechanism to offload work onto idle machines, and also to evict migrated processes when idle workstations are reclaimed by their owners. Sprite's migration mechanism provides a high degree of transparency both for migrated processes and for users. Idle machines are identified, and eviction is invoked, automatically by daemon processes. On Sprite it takes up to a few hundred milliseconds on SPARCstation 1 workstations to perform a remote exec, while evictions typically occur in a few seconds. The pmake program uses remote invocation to invoke tasks concurrently. Compilations commonly obtain speedup factors in the range of three to six; they are limited primarily by contention for centralized resources such as file servers. CPU-bound tasks such as simulations can make more effective use of idle hosts, obtaining as much as eight-fold speedup over a period of hours. Process migration has been in regular service for over two years.

Top