Sample records for high availability reliability

  1. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 3: HARP Graphics Oriented (GO) input user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.

  2. RELIABILITY, AVAILABILITY, AND SERVICEABILITY FOR PETASCALE HIGH-END COMPUTING AND BEYOND

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chokchai "Box" Leangsuksun

    2011-05-31

    Our project is a multi-institutional research effort that adopts interplay of RELIABILITY, AVAILABILITY, and SERVICEABILITY (RAS) aspects for solving resilience issues in highend scientific computing in the next generation of supercomputers. results lie in the following tracks: Failure prediction in a large scale HPC; Investigate reliability issues and mitigation techniques including in GPGPU-based HPC system; HPC resilience runtime & tools.

  3. Nutrition Environment Measures Survey in stores (NEMS-S): development and evaluation.

    PubMed

    Glanz, Karen; Sallis, James F; Saelens, Brian E; Frank, Lawrence D

    2007-04-01

    Eating, or nutrition, environments are believed to contribute to obesity and chronic diseases. There is a need for valid, reliable measures of nutrition environments. This article reports on the development and evaluation of measures of nutrition environments in retail food stores. The Nutrition Environment Measures Study developed observational measures of the nutrition environment within retail food stores (NEMS-S) to assess availability of healthy options, price, and quality. After pretesting, measures were completed by independent raters to evaluate inter-rater reliability and across two occasions to assess test-retest reliability in grocery and convenience stores in four neighborhoods differing on income and community design in the Atlanta metropolitan area. Data were collected and analyzed in 2004 and 2005. Ten food categories (e.g., fruits) or indicator food items (e.g., ground beef) were evaluated in 85 stores. Inter-rater reliability and test-retest reliability of availability were high: inter-rater reliability kappas were 0.84 to 1.00, and test-retest reliabilities were .73 to 1.00. Inter-rater reliability for quality across fresh produce was moderate (kappas, 0.44 to 1.00). Healthier options were higher priced for hot dogs, lean ground beef, and baked chips. More healthful options were available in grocery than convenience stores and in stores in higher income neighborhoods. The NEMS-S tool was found to have a high degree of inter-rater and test-retest reliability, and to reveal significant differences across store types and neighborhoods of high and low socioeconomic status. These observational measures of nutrition environments can be applied in multilevel studies of community nutrition, and can inform new approaches to conducting and evaluating nutrition interventions.

  4. One-year test-retest reliability of intrinsic connectivity network fMRI in older adults

    PubMed Central

    Guo, Cong C.; Kurth, Florian; Zhou, Juan; Mayer, Emeran A.; Eickhoff, Simon B; Kramer, Joel H.; Seeley, William W.

    2014-01-01

    “Resting-state” or task-free fMRI can assess intrinsic connectivity network (ICN) integrity in health and disease, suggesting a potential for use of these methods as disease-monitoring biomarkers. Numerous analytical options are available, including model-driven ROI-based correlation analysis and model-free, independent component analysis (ICA). High test-retest reliability will be a necessary feature of a successful ICN biomarker, yet available reliability data remains limited. Here, we examined ICN fMRI test-retest reliability in 24 healthy older subjects scanned roughly one year apart. We focused on the salience network, a disease-relevant ICN not previously subjected to reliability analysis. Most ICN analytical methods proved reliable (intraclass coefficients > 0.4) and could be further improved by wavelet analysis. Seed-based ROI correlation analysis showed high map-wise reliability, whereas graph theoretical measures and temporal concatenation group ICA produced the most reliable individual unit-wise outcomes. Including global signal regression in ROI-based correlation analyses reduced reliability. Our study provides a direct comparison between the most commonly used ICN fMRI methods and potential guidelines for measuring intrinsic connectivity in aging control and patient populations over time. PMID:22446491

  5. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 4: HARP Output (HARPO) graphics display user's guide

    NASA Technical Reports Server (NTRS)

    Sproles, Darrell W.; Bavuso, Salvatore J.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.

  6. Constellation Ground Systems Launch Availability Analysis: Enhancing Highly Reliable Launch Systems Design

    NASA Technical Reports Server (NTRS)

    Gernand, Jeffrey L.; Gillespie, Amanda M.; Monaghan, Mark W.; Cummings, Nicholas H.

    2010-01-01

    Success of the Constellation Program's lunar architecture requires successfully launching two vehicles, Ares I/Orion and Ares V/Altair, in a very limited time period. The reliability and maintainability of flight vehicles and ground systems must deliver a high probability of successfully launching the second vehicle in order to avoid wasting the on-orbit asset launched by the first vehicle. The Ground Operations Project determined which ground subsystems had the potential to affect the probability of the second launch and allocated quantitative availability requirements to these subsystems. The Ground Operations Project also developed a methodology to estimate subsystem reliability, availability and maintainability to ensure that ground subsystems complied with allocated launch availability and maintainability requirements. The verification analysis developed quantitative estimates of subsystem availability based on design documentation; testing results, and other information. Where appropriate, actual performance history was used for legacy subsystems or comparative components that will support Constellation. The results of the verification analysis will be used to verify compliance with requirements and to highlight design or performance shortcomings for further decision-making. This case study will discuss the subsystem requirements allocation process, describe the ground systems methodology for completing quantitative reliability, availability and maintainability analysis, and present findings and observation based on analysis leading to the Ground Systems Preliminary Design Review milestone.

  7. Inter-rater reliability of a food store checklist to assess availability of healthier alternatives to the energy-dense snacks and beverages commonly consumed by children.

    PubMed

    Izumi, Betty T; Findholt, Nancy E; Pickus, Hayley A; Nguyen, Thuan; Cuneo, Monica K

    2014-06-01

    Food stores have gained attention as potential intervention targets for improving children's eating habits. There is a need for valid and reliable instruments to evaluate changes in food store snack and beverage availability secondary to intervention. The aim of this study was to develop a valid, reliable, and resource-efficient instrument to evaluate the healthfulness of food store environments faced by children. The SNACZ food store checklist was developed to assess availability of healthier alternatives to the energy-dense snacks and beverages commonly consumed by children. After pretesting, two trained observers independently assessed the availability of 48 snack and beverage items in 50 food stores located near elementary and middle schools in Portland, Oregon, over a 2-week period in summer 2012. Inter-rater reliability was calculated using the kappa statistic. Overall, the instrument had mostly high inter-rater reliability. Seventy-three percent of items assessed had almost perfect or substantial reliability. Two items had moderate reliability (0.41-0.60), and no items had a reliability score less than 0.41. Eleven items occurred too infrequently to generate a kappa score. The SNACZ food store checklist is a first-step toward developing a valid and reliable tool to evaluate the healthfulness of food store environments faced by children. The tool can be used to compare availability of healthier snack and beverage alternatives across communities and measure change secondary to intervention. As a wider variety of healthier snack and beverage alternatives become available in food stores, the checklist should be updated.

  8. Reliability, Maintainability, and Availability: Consideration During the Design Phase in Ground Systems to Ensure Successful Launch Support

    NASA Technical Reports Server (NTRS)

    Gillespie, Amanda M.

    2012-01-01

    The future of Space Exploration includes missions to the moon, asteroids, Mars, and beyond. To get there, the mission concept is to launch multiple launch vehicles months, even years apart. In order to achieve this, launch vehicles, payloads (satellites and crew capsules), and ground systems must be highly reliable and/or available, to include maintenance concepts and procedures in the event of a launch scrub. In order to achieve this high probability of mission success, Ground Systems Development and Operations (GSDO) has allocated Reliability, Maintainability, and Availability (RMA) requirements to all hardware and software required for both launch operations and, in the event of a launch scrub, required to support a repair of the ground systems, launch vehicle, or payload. This is done concurrently with the design process (30/60/90 reviews).

  9. Texas nutrition environment assessment of retail food stores (TxNEA-S): development and evaluation.

    PubMed

    Gloria, Christian T; Steinhardt, Mary A

    2010-11-01

    Current nutrition environment instruments are typically designed to measure a small number of healthy foods based on national trends. They lack the depth to accurately measure the unique dietary choices of subpopulations, such as Texas consumers whose food preferences are influenced by Hispanic/Latino culture. Thus the purposes of the present study were to: (i) develop a comprehensive observational tool to measure the availability of healthy foods from retail stores in Texas; and (ii) conduct a pilot test to examine the tool's reliability, as well as differences in the availability of healthy foods in stores between high- and low-income neighbourhoods. Grocery and convenience stores were assessed for availability of healthy foods. Reliability was calculated using percentage agreement, and differences in availability were examined using 2 (store type) × 2 (neighbourhood income) ANOVA. One high-income and one low-income neighbourhood in Austin, Texas. A sample of thirty-eight stores comprising twenty-five convenience stores and thirteen grocery stores. The low-income neighbourhood had 324 % more convenience stores and 56 % fewer grocery stores than the high-income neighbourhood. High inter-rater (mean = 0·95) and test-retest reliability (mean = 0·92) and a significant interaction (P = 0·028) between store type and neighbourhood income were found. The TxNEA-S tool includes 106 healthy food items, such as fruits, vegetables, dairy, proteins and grains. The tool is reliable and face validity is affirmed by the Texas Department of Health. Grocery stores have more healthy foods than convenience stores, and high-income grocery stores offer more healthy foods than low-income grocery stores.

  10. Constellation Ground Systems Launch Availability Analysis: Enhancing Highly Reliable Launch Systems Design

    NASA Technical Reports Server (NTRS)

    Gernand, Jeffrey L.; Gillespie, Amanda M.; Monaghan, Mark W.; Cummings, Nicholas H.

    2010-01-01

    Success of the Constellation Program's lunar architecture requires successfully launching two vehicles, Ares I/Orion and Ares V/Altair, within a very limited time period. The reliability and maintainability of flight vehicles and ground systems must deliver a high probability of successfully launching the second vehicle in order to avoid wasting the on-orbit asset launched by the first vehicle. The Ground Operations Project determined which ground subsystems had the potential to affect the probability of the second launch and allocated quantitative availability requirements to these subsystems. The Ground Operations Project also developed a methodology to estimate subsystem reliability, availability, and maintainability to ensure that ground subsystems complied with allocated launch availability and maintainability requirements. The verification analysis developed quantitative estimates of subsystem availability based on design documentation, testing results, and other information. Where appropriate, actual performance history was used to calculate failure rates for legacy subsystems or comparative components that will support Constellation. The results of the verification analysis will be used to assess compliance with requirements and to highlight design or performance shortcomings for further decision making. This case study will discuss the subsystem requirements allocation process, describe the ground systems methodology for completing quantitative reliability, availability, and maintainability analysis, and present findings and observation based on analysis leading to the Ground Operations Project Preliminary Design Review milestone.

  11. A Report on Simulation-Driven Reliability and Failure Analysis of Large-Scale Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wan, Lipeng; Wang, Feiyi; Oral, H. Sarp

    High-performance computing (HPC) storage systems provide data availability and reliability using various hardware and software fault tolerance techniques. Usually, reliability and availability are calculated at the subsystem or component level using limited metrics such as, mean time to failure (MTTF) or mean time to data loss (MTTDL). This often means settling on simple and disconnected failure models (such as exponential failure rate) to achieve tractable and close-formed solutions. However, such models have been shown to be insufficient in assessing end-to-end storage system reliability and availability. We propose a generic simulation framework aimed at analyzing the reliability and availability of storagemore » systems at scale, and investigating what-if scenarios. The framework is designed for an end-to-end storage system, accommodating the various components and subsystems, their interconnections, failure patterns and propagation, and performs dependency analysis to capture a wide-range of failure cases. We evaluate the framework against a large-scale storage system that is in production and analyze its failure projections toward and beyond the end of lifecycle. We also examine the potential operational impact by studying how different types of components affect the overall system reliability and availability, and present the preliminary results« less

  12. High-reliability gas-turbine combined-cycle development program: Phase II. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hecht, K.G.; Sanderson, R.A.; Smith, M.J.

    This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. This volume presents information of the reliability, availability, and maintainability (RAM) analysis of a representative plant and the preliminary design of the gas turbine, the gas turbine ancillaries, and the balance of plant including themore » steam turbine generator. To achieve the program goals, a gas turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000 hours. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and mandual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-hour EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricity compared to present market offerings.« less

  13. Interphase Thermomechanical Reliability and Optimization for High-Performance Ti Metal Laminates

    DTIC Science & Technology

    2011-12-19

    Thermomechanical Reliability and Optimization for High-Performance Ti FA9550-08-l-0015 Metal Laminates Sb. GRANT NUMBER Program Manager: Dr Joycelyn Harrison...OSR-VA-TR-2012-0202 12. DISTRIBUTION/AVAILABILITY STATEMENT A 13. SUPPLEMENTARY NOTES 14. ABSTRACT Hybrid laminated composites such as titanium...graphite (TiGr) laminates are an emerging class of structural materials with the potential to enable a new generation of efficient, high-performance

  14. Standard high-reliability integrated circuit logic packaging. [for deep space tracking stations

    NASA Technical Reports Server (NTRS)

    Slaughter, D. W.

    1977-01-01

    A family of standard, high-reliability hardware used for packaging digital integrated circuits is described. The design transition from early prototypes to production hardware is covered and future plans are discussed. Interconnections techniques are described as well as connectors and related hardware available at both the microcircuit packaging and main-frame level. General applications information is also provided.

  15. Highly Survivable Avionics Systems for Long-Term Deep Space Exploration

    NASA Technical Reports Server (NTRS)

    Alkalai, L.; Chau, S.; Tai, A. T.

    2001-01-01

    The design of highly survivable avionics systems for long-term (> 10 years) exploration of space is an essential technology for all current and future missions in the Outer Planets roadmap. Long-term exposure to extreme environmental conditions such as high radiation and low-temperatures make survivability in space a major challenge. Moreover, current and future missions are increasingly using commercial technology such as deep sub-micron (0.25 microns) fabrication processes with specialized circuit designs, commercial interfaces, processors, memory, and other commercial off the shelf components that were not designed for long-term survivability in space. Therefore, the design of highly reliable, and available systems for the exploration of Europa, Pluto and other destinations in deep-space require a comprehensive and fresh approach to this problem. This paper summarizes work in progress in three different areas: a framework for the design of highly reliable and highly available space avionics systems, distributed reliable computing architecture, and Guarded Software Upgrading (GSU) techniques for software upgrading during long-term missions. Additional information is contained in the original extended abstract.

  16. Home food and activity assessment. Development and validation of an instrument for diverse families of young children.

    PubMed

    Boles, Richard E; Burdell, Alexandra; Johnson, Susan L; Gavin, William J; Davies, Patricia L; Bellows, Laura L

    2014-09-01

    The purpose of this study was to refine and psychometrically test an instrument measuring the home food and activity environment of geographically and economically diverse families of preschool aged children. Caregivers of preschool aged children (n = 83) completed a modified self-report questionnaire. Reliably trained researchers conducted independent observations on 25 randomly selected homes. Agreement statistics were conducted at the item level (154 total items) to determine reliability. Frequency counts were calculated to identify item availability. Results showed Kappa statistics were high (.67-1.00) between independent researchers but varied between researchers and parents resulting in 85 items achieving criterion validity (Kappa >.60). Analyses of reliable items revealed the presence in the home of a high frequency of unhealthy snack foods, high fat milk and low frequency of availability of fruits/vegetables and low fat milk. Fifty-two percent of the homes were arranged with a television in the preschool child's bedroom. Physical Activity devices also were found to have high frequency availability. Families reporting lower education reported higher levels of sugar sweetened beverages and less low-fat dairy (p < .05) compared with higher education families. Low-income families (<$27K per year) reported significantly fewer Physical Activity devices (p < .001) compared with higher income families. Hispanic families reported significantly higher numbers of Sedentary Devices (p < .05) compared with non-Hispanic families. There were no significant differences between demographic comparisons on available fruits/vegetables, meats, whole grains, and regular fat dairy. A modified home food and activity instrument was found to reliably identify foods and activity devices with geographically and economically diverse families. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Technology developments toward 30-year-life of photovoltaic modules

    NASA Technical Reports Server (NTRS)

    Ross, R. G., Jr.

    1984-01-01

    As part of the United States National Photovoltaics Program, the Jet Propulsion Laboratory's Flat-Plate Solar Array Project (FSA) has maintained a comprehensive reliability and engineering sciences activity addressed toward understanding the reliability attributes of terrestrial flat-plate photovoltaic arrays and to deriving analysis and design tools necessary to achieve module designs with a 30-year useful life. The considerable progress to date stemming from the ongoing reliability research is discussed, and the major areas requiring continued research are highlighted. The result is an overview of the total array reliability problem and of available means of achieving high reliability at minimum cost.

  18. The Case for Modular Redundancy in Large-Scale High Performance Computing Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelmann, Christian; Ong, Hong Hoe; Scott, Stephen L

    2009-01-01

    Recent investigations into resilience of large-scale high-performance computing (HPC) systems showed a continuous trend of decreasing reliability and availability. Newly installed systems have a lower mean-time to failure (MTTF) and a higher mean-time to recover (MTTR) than their predecessors. Modular redundancy is being used in many mission critical systems today to provide for resilience, such as for aerospace and command \\& control systems. The primary argument against modular redundancy for resilience in HPC has always been that the capability of a HPC system, and respective return on investment, would be significantly reduced. We argue that modular redundancy can significantly increasemore » compute node availability as it removes the impact of scale from single compute node MTTR. We further argue that single compute nodes can be much less reliable, and therefore less expensive, and still be highly available, if their MTTR/MTTF ratio is maintained.« less

  19. Reliability issues of free-space communications systems and networks

    NASA Astrophysics Data System (ADS)

    Willebrand, Heinz A.

    2003-04-01

    Free space optics (FSO) is a high-speed point-to-point connectivity solution traditionally used in the enterprise campus networking market for building-to-building LAN connectivity. However, more recently some wire line and wireless carriers started to deploy FSO systems in their networks. The requirements on FSO system reliability, meaing both system availability and component reliability, are far more stringent in the carrier market when compared to the requirements in the enterprise market segment. This paper tries to outline some of the aspects that are important to ensure carrier class system reliability.

  20. Chicanoizing Drug Abuse Programs

    ERIC Educational Resources Information Center

    Aron, William S.; And Others

    1974-01-01

    Focus is on the community of La Colonia in Oxnard, California because it has (1) a high concentration of Mexican Americans, (2) a high incidence of drug addiction, and (3) reliable statistical data available. (NQ)

  1. Deterministic Ethernet for Space Applications

    NASA Astrophysics Data System (ADS)

    Fidi, C.; Wolff, B.

    2015-09-01

    Typical spacecraft systems are distributed to be able to achieve the required reliability and availability targets of the mission. However the requirements on these systems are different for launchers, satellites, human space flight and exploration missions. Launchers require typically high reliability with very short mission times whereas satellites or space exploration missions require very high availability at very long mission times. Comparing a distributed system of launchers with satellites it shows very fast reaction times in launchers versus much slower once in satellite applications. Human space flight missions are maybe most challenging concerning reliability and availability since human lives are involved and the mission times can be very long e.g. ISS. Also the reaction times of these vehicles can get challenging during mission scenarios like landing or re-entry leading to very fast control loops. In these different applications more and more autonomous functions are required to fulfil the needs of current and future missions. This autonomously leads to new requirements with respect to increase performance, determinism, reliability and availability. On the other hand side the pressure on reducing costs of electronic components in space applications is increasing, leading to the use of more and more COTS components especially for launchers and LEO satellites. This requires a technology which is able to provide a cost competitive solution for both the high reliable and available deep-space as well as the low cost “new space” markets. Future spacecraft communication standards therefore have to be much more flexible, scalable and modular to be able to deal with these upcoming challenges. The only way to fulfill these requirements is, if they are based on open standards which are used cross industry leading to a reduction of the lifecycle costs and an increase in performance. The use of a communication network that fulfills these requirements will be essential for such spacecraft’s to allow the use in launcher, satellite, human space flight and exploration missions. Using one technology and the related infrastructure for these different applications will lead to a significant reduction of complexity and would moreover lead to significant savings in size weight and power while increasing the performance of the overall system. The paper focuses on the use of the TTEthernet technology for launchers, satellites and human spaceflight and will demonstrate the scalability of the technology for the different applications. The data used is derived from the ESA TRP 7594 on “Reliable High-Speed Data Bus/Network for Safety-Oriented Missions”.

  2. Modeling Electricity Sector Vulnerabilities and Costs Associated with Water Temperatures Under Scenarios of Climate Change

    NASA Astrophysics Data System (ADS)

    Macknick, J.; Miara, A.; Brinkman, G.; Ibanez, E.; Newmark, R. L.

    2014-12-01

    The reliability of the power sector is highly vulnerable to variability in the availability and temperature of water resources, including those that might result from potential climatic changes or from competition from other users. In the past decade, power plants throughout the United States have had to shut down or curtail generation due to a lack of available water or from elevated water temperatures. These disruptions in power plant performance can have negative impacts on energy security and can be costly to address. Analysis of water-related vulnerabilities requires modeling capabilities with high spatial and temporal resolution. This research provides an innovative approach to energy-water modeling by evaluating the costs and reliability of a power sector region under policy and climate change scenarios that affect water resource availability and temperatures. This work utilizes results from a spatially distributed river water temperature model coupled with a thermoelectric power plant model to provide inputs into an electricity production cost model that operates on a high spatial and temporal resolution. The regional transmission organization ISO-New England, which includes six New England states and over 32 Gigawatts of power capacity, is utilized as a case study. Hydrological data and power plant operations are analyzed over an eleven year period from 2000-2010 under four scenarios that include climate impacts on water resources and air temperatures as well as strict interpretations of regulations that can affect power plant operations due to elevated water temperatures. Results of these model linkages show how the power sector's reliability and economic performance can be affected by changes in water temperatures and water availability. The effective reliability and capacity value of thermal electric generators are quantified and discussed in the context of current as well as potential future water resource characteristics.

  3. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    PubMed

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Long life, high speed, thrust-load ball bearings

    NASA Technical Reports Server (NTRS)

    Signer, H.; Bamberger, E. N.; Zaretsky, E. V.

    1975-01-01

    Long-term bearing operation at three million DN can be achieved with high degree of reliability using full combination of sophisticated but currently available state-of-the-art bearing materials and designs, lubricants, and lubricating techniques.

  5. Advanced Stirling Convertor Heater Head Durability and Reliability Quantification

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Shah, Ashwin R.; Korovaichuk, Igor; Kalluri, Sreeramesh

    2008-01-01

    The National Aeronautics and Space Administration (NASA) has identified the high efficiency Advanced Stirling Radioisotope Generator (ASRG) as a candidate power source for long duration Science missions, such as lunar applications, Mars rovers, and deep space missions, that require reliable design lifetimes of up to 17 years. Resistance to creep deformation of the MarM-247 heater head (HH), a structurally critical component of the ASRG Advanced Stirling Convertor (ASC), under high temperatures (up to 850 C) is a key design driver for durability. Inherent uncertainties in the creep behavior of the thin-walled HH and the variations in the wall thickness, control temperature, and working gas pressure need to be accounted for in the life and reliability prediction. Due to the availability of very limited test data, assuring life and reliability of the HH is a challenging task. The NASA Glenn Research Center (GRC) has adopted an integrated approach combining available uniaxial MarM-247 material behavior testing, HH benchmark testing and advanced analysis in order to demonstrate the integrity, life and reliability of the HH under expected mission conditions. The proposed paper describes analytical aspects of the deterministic and probabilistic approaches and results. The deterministic approach involves development of the creep constitutive model for the MarM-247 (akin to the Oak Ridge National Laboratory master curve model used previously for Inconel 718 (Special Metals Corporation)) and nonlinear finite element analysis to predict the mean life. The probabilistic approach includes evaluation of the effect of design variable uncertainties in material creep behavior, geometry and operating conditions on life and reliability for the expected life. The sensitivity of the uncertainties in the design variables on the HH reliability is also quantified, and guidelines to improve reliability are discussed.

  6. System reliability analysis through corona testing

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.

    1975-01-01

    In the Reliability and Quality Engineering Test Laboratory at the NASA Lewis Research Center a nondestructive, corona-vacuum test facility for testing power system components was developed using commercially available hardware. The test facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. This facility is being used to test various high voltage power system components.

  7. Fault diagnostic instrumentation design for environmental control and life support systems

    NASA Technical Reports Server (NTRS)

    Yang, P. Y.; You, K. C.; Wynveen, R. A.; Powell, J. D., Jr.

    1979-01-01

    As a development phase moves toward flight hardware, the system availability becomes an important design aspect which requires high reliability and maintainability. As part of continous development efforts, a program to evaluate, design, and demonstrate advanced instrumentation fault diagnostics was successfully completed. Fault tolerance designs for reliability and other instrumenation capabilities to increase maintainability were evaluated and studied.

  8. Assessing reliability of short and tick box forms of the ANU-ADRI: Convenient alternatives of a self-report Alzheimer's disease risk assessment.

    PubMed

    Kim, Sarang; Cherbuin, Nicolas; Anstey, Kaarin J

    2016-06-01

    To assess the reliability of short versions of the Australian National University Alzheimer's Disease Risk Index (ANU-ADRI). A short form of the ANU-ADRI (ANU-ADRI-SF) was developed by assessing risk and protective factors with single questions where possible and with short forms of sub-questionnaires where available. The tick box form of the ANU-ADRI (ANU-ADRI-TB) was developed with unique questions for each risk and protective factor for Alzheimer's disease. The short versions were evaluated in an independent community sample of 504 participants with a mean age of 45.01 (SD = 14.85, range = 18-81). The short versions demonstrated high reliabilities when compared with the ANU-ADRI. However, the proportion of misclassification was high for some risk factors and particularly for the ANU-ADRI-TB. The ANU-ADRI-SF may be considered if less reliable questions from the ANU-ADRI-SF can be replaced with more reliable questions from the ANU-ADRI for risk/protective factors with high misclassification.

  9. MASH Suite: a user-friendly and versatile software interface for high-resolution mass spectrometry data interpretation and visualization.

    PubMed

    Guner, Huseyin; Close, Patrick L; Cai, Wenxuan; Zhang, Han; Peng, Ying; Gregorich, Zachery R; Ge, Ying

    2014-03-01

    The rapid advancements in mass spectrometry (MS) instrumentation, particularly in Fourier transform (FT) MS, have made the acquisition of high-resolution and high-accuracy mass measurements routine. However, the software tools for the interpretation of high-resolution MS data are underdeveloped. Although several algorithms for the automatic processing of high-resolution MS data are available, there is still an urgent need for a user-friendly interface with functions that allow users to visualize and validate the computational output. Therefore, we have developed MASH Suite, a user-friendly and versatile software interface for processing high-resolution MS data. MASH Suite contains a wide range of features that allow users to easily navigate through data analysis, visualize complex high-resolution MS data, and manually validate automatically processed results. Furthermore, it provides easy, fast, and reliable interpretation of top-down, middle-down, and bottom-up MS data. MASH Suite is convenient, easily operated, and freely available. It can greatly facilitate the comprehensive interpretation and validation of high-resolution MS data with high accuracy and reliability.

  10. High Available COTS Based Computer for Space

    NASA Astrophysics Data System (ADS)

    Hartmann, J.; Magistrati, Giorgio

    2015-09-01

    The availability and reliability factors of a system are central requirements of a target application. From a simple fuel injection system used in cars up to a flight control system of an autonomous navigating spacecraft, each application defines its specific availability factor under the target application boundary conditions. Increasing quality requirements on data processing systems used in space flight applications calling for new architectures to fulfill the availability, reliability as well as the increase of the required data processing power. Contrary to the increased quality request simplification and use of COTS components to decrease costs while keeping the interface compatibility to currently used system standards are clear customer needs. Data processing system design is mostly dominated by strict fulfillment of the customer requirements and reuse of available computer systems were not always possible caused by obsolescence of EEE-Parts, insufficient IO capabilities or the fact that available data processing systems did not provide the required scalability and performance.

  11. Reliability culture at La Silla Paranal Observatory

    NASA Astrophysics Data System (ADS)

    Gonzalez, Sergio

    2010-07-01

    The Maintenance Department at the La Silla - Paranal Observatory has been an important base to keep the operations of the observatory at a good level of reliability and availability. Several strategies have been implemented and improved in order to cover these requirements and keep the system and equipment working properly when it is required. For that reason, one of the latest improvements has been the introduction of the concept of reliability, which implies that we don't simply speak about reliability concepts. It involves much more than that. It involves the use of technologies, data collecting, data analysis, decision making, committees concentrated in analysis of failure modes and how they can be eliminated, aligning the results with the requirements of our internal partners and establishing steps to achieve success. Some of these steps have already been implemented: data collection, use of technologies, analysis of data, development of priority tools, committees dedicated to analyze data and people dedicated to reliability analysis. This has permitted us to optimize our process, analyze where we can improve, avoid functional failures, reduce the failures range in several systems and subsystems; all this has had a positive impact in terms of results for our Observatory. All these tools are part of the reliability culture that allows our system to operate with a high level of reliability and availability.

  12. Critical issues in assuring long lifetime and fail-safe operation of optical communications network

    NASA Astrophysics Data System (ADS)

    Paul, Dilip K.

    1993-09-01

    Major factors in assuring long lifetime and fail-safe operation in optical communications networks are reviewed in this paper. Reliable functionality to design specifications, complexity of implementation, and cost are the most critical issues. As economics is the driving force to set the goals as well as priorities for the design, development, safe operation, and maintenance schedules of reliable networks, a balance is sought between the degree of reliability enhancement, cost, and acceptable outage of services. Protecting both the link and the network with high reliability components, hardware duplication, and diversity routing can ensure the best network availability. Case examples include both fiber optic and lasercom systems. Also, the state-of-the-art reliability of photonics in space environment is presented.

  13. High Availability in Optical Networks

    NASA Astrophysics Data System (ADS)

    Grover, Wayne D.; Wosinska, Lena; Fumagalli, Andrea

    2005-09-01

    Call for Papers: High Availability in Optical Networks Submission Deadline: 1 January 2006 The Journal of Optical Networking (JON) is soliciting papers for a feature Issue pertaining to all aspects of reliable components and systems for optical networks and concepts, techniques, and experience leading to high availability of services provided by optical networks. Most nations now recognize that telecommunications in all its forms -- including voice, Internet, video, and so on -- are "critical infrastructure" for the society, commerce, government, and education. Yet all these services and applications are almost completely dependent on optical networks for their realization. "Always on" or apparently unbreakable communications connectivity is the expectation from most users and for some services is the actual requirement as well. Achieving the desired level of availability of services, and doing so with some elegance and efficiency, is a meritorious goal for current researchers. This requires development and use of high-reliability components and subsystems, but also concepts for active reconfiguration and capacity planning leading to high availability of service through unseen fast-acting survivability mechanisms. The feature issue is also intended to reflect some of the most important current directions and objectives in optical networking research, which include the aspects of integrated design and operation of multilevel survivability and realization of multiple Quality-of-Protection service classes. Dynamic survivable service provisioning, or batch re-provisioning is an important current theme, as well as methods that achieve high availability at far less investment in spare capacity than required by brute force service path duplication or 100% redundant rings, which is still the surprisingly prevalent practice. Papers of several types are envisioned in the feature issue, including outlook and forecasting types of treatments, optimization and analysis, new concepts for survivability, or papers on availability analysis methods or results. Customer, vendor, and researcher viewpoints and priorities will all be given consideration. Especially valuable to the community would be papers that include or provide measured data on actual reliability and availability performance of optical networking components or systems. The scope of the papers includes, but is not limited to, the following topics: Reliability and availability measurement techniques specific to optical network devices or services. Data on SRLG statistics and frequency of different actual failure causes. Real-life accounts or data on failure and repair rates or projected values for use in availability analysis. Availability analysis methods, especially for survivable networks with reconfigurable or adaptive failure-specific responses. Availability analysis and comparisons of basic schemes for survivability. Differentiated availability schemes. Design for Multiple Quality of Protection. Different schemes for on-demand survivable service provisioning. Basic comparisons or proposals of new survivability mechanisms and architectures. Concepts yielding higher than 1+1 protection switching availability at less than 100% redundancy. Survivable service provisioning in domains of optical transparency: dealing with signal impairments. To submit to this special issue, follow the normal procedure for submission to JON, indicating "Feature Issue: Optical Network Availability" in the "Comments" field of the online submission form. For all other questions relating to this feature issue, please send an e-mail to jon@osa.org, subject line "Feature Issue: Optical Network Availability." Additional information can be found on the JON website: http://www.osa-jon.org/submission/

  14. Analysis of key thresholds leading to upstream dependencies in global transboundary water bodies

    NASA Astrophysics Data System (ADS)

    Munia, Hafsa Ahmed; Guillaume, Joseph; Kummu, Matti; Mirumachi, Naho; Wada, Yoshihide

    2017-04-01

    Transboundary water bodies supply 60% of global fresh water flow and are home to about 1/3 of the world's population; creating hydrological, social and economic interdependencies between countries. Trade-offs between water users are delimited by certain thresholds, that, when crossed, result in changes in system behavior, often related to undesirable impacts. A wide variety of thresholds are potentially related to water availability and scarcity. Scarcity can occur because of the country's own water use, and that is potentially intensified by upstream water use. In general, increased water scarcity escalates the reliance on shared water resources, which increases interdependencies between riparian states. In this paper the upstream dependencies of global transboundary river basins are examined at the scale of sub-basin areas. We aim to assess how upstream water withdrawals cause changes in the scarcity categories, such that crossing thresholds is interpreted in terms of downstream dependency on upstream water availability. The thresholds are defined for different types of water availability on which a sub-basin relies: - reliable local runoff (available even in a dry year), - less reliable local water (available in the wet year), - reliable dry year inflows from possible upstream area, and - less reliable wet year inflows from upstream. Possible upstream withdrawals reduce available water downstream, influencing the latter two water availabilities. Upstream dependencies have then been categorized by comparing a sub-basin's scarcity category across different water availability types. When population (or water consumption) grows, the sub-basin satisfies its needs using less reliable water. Thus, the factors affecting the type of water availability being used are different not only for each type of dependency category, but also possibly for every sub- basin. Our results show that, in the case of stress (impacts from high use of water), in 104 (12%) sub- basins out of 886 sub-basins are dependent on upstream water, while in the case of shortage (impacts from insufficient water availability per person), 79 (9%) sub-basins out of 886 sub-basins dependent on upstream water. Categorization of the upstream dependency of the sub-basins helps to differentiate between areas where i) there is currently no dependency on upstream water, ii) upstream water withdrawals are sufficiently high that they alter the scarcity and dependency status, and iii) which are always dependent on upstream water regardless of upstream water withdrawals. Our dependency assessment is expected to considerably support the studies and discussions of hydro-political power relations and management practices in transboundary basins.

  15. Traveling-wave tube reliability estimates, life tests, and space flight experience

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Speck, C. E.

    1977-01-01

    Infant mortality, useful life, and wearout phase of twt life are considered. The performance of existing developmental tubes, flight experience, and sequential hardware testing are evaluated. The reliability history of twt's in space applications is documented by considering: (1) the generic parts of the tube in light of the manner in which their design and operation affect the ultimate reliability of the device, (2) the flight experience of medium power tubes, and (3) the available life test data for existing space-qualified twt's in addition to those of high power devices.

  16. Fast gas spectroscopy using pulsed quantum cascade lasers

    NASA Astrophysics Data System (ADS)

    Beyer, T.; Braun, M.; Lambrecht, A.

    2003-03-01

    Laser spectroscopy has found many industrial applications, e.g., control of automotive exhaust and process monitoring. The midinfrared region is of special interest because it has stronger absorption lines compared to the near infrared (NIR). However, in the NIR high quality reliable laser sources, detectors, and passive optical components are available. A quantum cascade laser could change this situation if fundamental advantages can be exploited with compact and reliable systems. It will be shown that, using pulsed lasers and available fast detectors, lower residual sensitivity levels than in corresponding NIR systems can be achieved. The stability is sufficient for industrial applications.

  17. 18 CFR 40.3 - Availability of Reliability Standards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Availability of Reliability Standards. 40.3 Section 40.3 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... THE BULK-POWER SYSTEM § 40.3 Availability of Reliability Standards. The Electric Reliability...

  18. Active Reliability Engineering - Technical Concept and Program Plan. A Solid-State Systems Approach to Increased Reliability and Availability in Military Systems.

    DTIC Science & Technology

    1983-10-05

    battle damage. Others are local electrical power and cooling disruptions. Again, a highly critical function is lost if its computer site is destroyed. A...formalized design of the test bed to meet the requirements of the functional description and goals of the program. AMTEC --Z3IT TASKS: 610, 710, 810

  19. Overview of RICOR's reliability theoretical analysis, accelerated life demonstration test results and verification by field data

    NASA Astrophysics Data System (ADS)

    Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey

    2018-05-01

    The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.

  20. 76 FR 4920 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-27

    ... appear to be distinct from each other. Available for licensing is a Plk1 ELISA assay using peptide... binding property, an easy and reliable ELISA assay has been developed to quantify Plk1 expression levels... sequence. ELISA assay to quantify Plk1 expression and kinase activity. Advantages: Rapid, highly sensitive...

  1. Threat distractor and perceptual load modulate test-retest reliability of anterior cingulate cortex response.

    PubMed

    Bunford, Nora; Kinney, Kerry L; Michael, Jamie; Klumpp, Heide

    2017-07-03

    Accumulating data from fMRI studies implicate the rostral anterior cingulate cortex (rACC) in inhibition of attention to threat distractors that compete with task-relevant goals for processing resources. However, little data is available on the reliability of rACC activation. Our aim in the current study was to examine test-retest reliability of rACC activation over a 12-week period, in the context of a validated emotional interference paradigm that varied in perceptual load. During functional MRI, 23 healthy volunteers completed a task involving a target letter in a string of identical letters (low load) or in a string of mixed letters (high load) superimposed on angry, fearful, and neutral face distractors. Intraclass correlation coefficients (ICCs) indicated that under low, but not high perceptual load, rACC activation to fearful vs. neutral distractors was moderately reliable. Conversely, regardless of perceptual load, rACC activation to angry vs. neutral distractors was not reliable. Regarding behavioral performance, ICCs indicated that accuracy was not reliable regardless of distractor type or perceptual load. Although reaction time (RT) was similarly not reliable regardless of distractor type under low perceptual load, RT to angry vs. neutral distractors and to fearful vs. neutral distractors was reliable under high perceptual load. Together, results indicate the test-retest reliability of rACC activation and corresponding behavioral performance are context dependent; reliability of the former varies as a function of distractor type and level of cognitive demand, whereas reliability of the latter depends on behavioral index (accuracy vs. RT) and level of cognitive demand but not distractor type. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Flexible Transparent Conductive Films with High Performance and Reliability Using Hybrid Structures of Continuous Metal Nanofiber Networks for Flexible Optoelectronics.

    PubMed

    Park, Juyoung; Hyun, Byung Gwan; An, Byeong Wan; Im, Hyeon-Gyun; Park, Young-Geun; Jang, Junho; Park, Jang-Ung; Bae, Byeong-Soo

    2017-06-21

    We report an Ag nanofiber-embedded glass-fabric reinforced hybrimer (AgNF-GFRHybrimer) composite film as a reliable and high-performance flexible transparent conducting film. The continuous AgNF network provides superior optoelectronic properties of the composite film by minimizing transmission loss and junction resistance. In addition, the excellent thermal/chemical stability and mechanical durability of the GFRHybrimer matrix provides enhanced mechanical durability and reliability of the final AgNF-GFRHybrimer composite film. To demonstrate the availability of our AgNF-GFRHybrimer composite as a transparent conducting film, we fabricated a flexible organic light-emitting diode (OLED) device on the AgNF-GFRHybrimer film; the OLED showed stable operation during a flexing.

  3. Thermal Cycle Reliability and Failure Mechanisms of CCGA and PBGA Assemblies with and without Corner Staking

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2008-01-01

    Area array packages (AAPs) with 1.27 mm pitch have been the packages of choice for commercial applications; they are now starting to be implemented for use in military and aerospace applications. Thermal cycling characteristics of plastic ball grid array (PBGA) and chip scale package assemblies, because of their wide usage for commercial applications, have been extensively reported on in literature. Thermal cycling represents the on-off environmental condition for most electronic products and therefore is a key factor that defines reliability.However, very limited data is available for thermal cycling behavior of ceramic packages commonly used for the aerospace applications. For high reliability applications, numerous AAPs are available with an identical design pattern both in ceramic and plastic packages. This paper compares assembly reliability of ceramic and plastic packages with the identical inputs/outputs(I/Os) and pattern. The ceramic package was in the form of ceramic column grid array (CCGA) with 560 I/Os peripheral array with the identical pad design as its plastic counterpart.

  4. MOLAR: Modular Linux and Adaptive Runtime Support for HEC OS/R Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frank Mueller

    2009-02-05

    MOLAR is a multi-institution research effort that concentrates on adaptive, reliable,and efficient operating and runtime system solutions for ultra-scale high-end scientific computing on the next generation of supercomputers. This research addresses the challenges outlined by the FAST-OS - forum to address scalable technology for runtime and operating systems --- and HECRTF --- high-end computing revitalization task force --- activities by providing a modular Linux and adaptable runtime support for high-end computing operating and runtime systems. The MOLAR research has the following goals to address these issues. (1) Create a modular and configurable Linux system that allows customized changes based onmore » the requirements of the applications, runtime systems, and cluster management software. (2) Build runtime systems that leverage the OS modularity and configurability to improve efficiency, reliability, scalability, ease-of-use, and provide support to legacy and promising programming models. (3) Advance computer reliability, availability and serviceability (RAS) management systems to work cooperatively with the OS/R to identify and preemptively resolve system issues. (4) Explore the use of advanced monitoring and adaptation to improve application performance and predictability of system interruptions. The overall goal of the research conducted at NCSU is to develop scalable algorithms for high-availability without single points of failure and without single points of control.« less

  5. High-rate multi-GNSS: what does it mean to seismology?

    NASA Astrophysics Data System (ADS)

    Geng, J.

    2017-12-01

    GNSS precise point positioning (PPP) is capable of measuring centimeter-level positions epoch by epoch at a single station, and is thus treasured in tsunami/earthquake early warning where static displacements in the near field are critical to rapidly and reliably determining the magnitude of destructive events. However, most operational real-time PPP systems at present rely on only GPS data. The deficiency of such systems is that the high reliability and availability of precise displacements cannot be maintained continuously in real time, which is however a crucial requirement for disaster resistance and response. Multi-GNSS, including GLONASS, BeiDou, Galileo and QZSS other than only GPS, can be a solution to this problem because much more satellites per epoch (e.g. 30-40) will be available. In this case, positioning failure due to data loss or blunders can be minimized, and on the other hand, positioning initializations can be accelerated to a great extent since the satellite geometry for each epoch will be enhanced enormously. We established a prototype real-time multi-GNSS PPP service based on Asia-Pacific real-time network which can collect and stream high-rate data from all five navigation systems above. We estimated high-rate satellite clock corrections and enabled undifferenced ambiguity fixing for multi-GNSS, which therefore ensures high availability and reliability of precise displacement estimates in contrast to GPS-only systems. We will report how we can benefit from multi-GNSS for seismology, especially the noise characteristics of high-rate and sub-daily displacements. We will also use storm surge loading events to demonstrate the contribution of multi-GNSS to sub-daily transient signals.

  6. Reliability and economy -- Hydro electricity for Iran

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahromi-Shirazi, M.J.; Zarbakhsh, M.H.

    1998-12-31

    Reliability is the probability that a device or system will perform its function adequately, for the period of time intended, under the operating conditions intended. Reliability and economy are two important factors in operating any system, especially in power generation. Due to the high rate in population growth in Iran, the experts have estimated that the demand for electricity will be about 63,000 MW in the next 25 years, the installed power is now about 26,000 MW. Therefore, the energy policy decision made in Iran is to go to power generation by hydroelectric plants because of reliability, availability of watermore » resources and the economics of hydroelectric power.« less

  7. Verification Methodology of Fault-tolerant, Fail-safe Computers Applied to MAGLEV Control Computer Systems

    DOT National Transportation Integrated Search

    1993-05-01

    The Maglev control computer system should be designed to verifiably possess high reliability and safety as well as high availability to make Maglev a dependable and attractive transportation alternative to the public. A Maglev computer system has bee...

  8. Wide Bandgap Extrinsic Photoconductive Switches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, James S.

    2012-01-20

    Photoconductive semiconductor switches (PCSS) have been investigated since the late 1970s. Some devices have been developed that withstand tens of kilovolts and others that switch hundreds of amperes. However, no single device has been developed that can reliably withstand both high voltage and switch high current. Yet, photoconductive switches still hold the promise of reliable high voltage and high current operation with subnanosecond risetimes. Particularly since good quality, bulk, single crystal, wide bandgap semiconductor materials have recently become available. In this chapter we will review the basic operation of PCSS devices, status of PCSS devices and properties of the widemore » bandgap semiconductors 4H-SiC, 6H-SiC and 2H-GaN.« less

  9. Reliability and Applicability of Aerodynamic Measures in Dysphonia Assessment

    ERIC Educational Resources Information Center

    Yiu, Edwin M.-L.; Yuen, Yuet-Ming; Whitehill, Tara; Winkworth, Alison

    2004-01-01

    Aerodynamic measures are frequently used to analyse and document pathological voices. Some normative data are available for speakers from the English-speaking population. However, no data are available yet for Chinese speakers despite the fact that they are one of the largest populations in the world. The high variability of aerodynamic measures…

  10. High resolution time interval meter

    DOEpatents

    Martin, A.D.

    1986-05-09

    Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

  11. Remote Energy Monitoring System via Cellular Network

    NASA Astrophysics Data System (ADS)

    Yunoki, Shoji; Tamaki, Satoshi; Takada, May; Iwaki, Takashi

    Recently, improvement on power saving and cost efficiency by monitoring the operation status of various facilities over the network has gained attention. Wireless network, especially cellular network, has advantage in mobility, coverage, and scalability. On the other hand, it has disadvantage of low reliability, due to rapid changes in the available bandwidth. We propose a transmission control scheme based on data priority and instantaneous available bandwidth to realize a highly reliable remote monitoring system via cellular network. We have developed our proposed monitoring system and evaluated the effectiveness of our scheme, and proved it reduces the maximum transmission delay of sensor status to 1/10 compared to best effort transmission.

  12. The children's menu assessment: development, evaluation, and relevance of a tool for evaluating children's menus.

    PubMed

    Krukowski, Rebecca A; Eddings, Kenya; West, Delia Smith

    2011-06-01

    Restaurant foods represent a substantial portion of children's dietary intake, and consumption of foods away from home has been shown to contribute to excess adiposity. This descriptive study aimed to pilot-test and establish the reliability of a standardized and comprehensive assessment tool, the Children's Menu Assessment, for evaluating the restaurant food environment for children. The tool is an expansion of the Nutrition Environment Measures Survey-Restaurant. In 2009-2010, a randomly selected sample of 130 local and chain restaurants were chosen from within 20 miles of Little Rock, AR, to examine the availability of children's menus and to conduct initial calibration of the Children's Menu Assessment tool (final sample: n=46). Independent raters completed the Children's Menu Assessment in order to determine inter-rater reliability. Test-retest reliability was also examined. Inter-rater reliability was high: percent agreement was 97% and Spearman correlation was 0.90. Test-retest was also high: percent agreement was 91% and Spearman correlation was 0.96. Mean Children's Menu Assessment completion time was 14 minutes, 56 seconds ± 10 minutes, 21 seconds. Analysis of Children's Menu Assessment findings revealed that few healthier options were available on children's menus, and most menus did not provide parents with information for making healthy choices, including nutrition information or identification of healthier options. The Children's Menu Assessment tool allows for comprehensive, rapid measurement of the restaurant food environment for children with high inter-rater reliability. This tool has the potential to contribute to public health efforts to develop and evaluate targeted environmental interventions and/or policy changes regarding restaurant foods. Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  13. Quality of information available on the World Wide Web for patients undergoing thyroidectomy: review.

    PubMed

    Muthukumarasamy, S; Osmani, Z; Sharpe, A; England, R J A

    2012-02-01

    This study aimed to assess the quality of information available on the World Wide Web for patients undergoing thyroidectomy. The first 50 web-links generated by internet searches using the five most popular search engines and the key word 'thyroidectomy' were evaluated using the Lida website validation instrument (assessing accessibility, usability and reliability) and the Flesch Reading Ease Score. We evaluated 103 of a possible 250 websites. Mean scores (ranges) were: Lida accessibility, 48/63 (27-59); Lida usability, 36/54 (21-50); Lida reliability, 21/51 (4-38); and Flesch Reading Ease, 43.9 (2.6-77.6). The quality of internet health information regarding thyroidectomy is variable. High ranking and popularity are not good indicators of website quality. Overall, none of the websites assessed achieved high Lida scores. In order to prevent the dissemination of inaccurate or commercially motivated information, we recommend independent labelling of medical information available on the World Wide Web.

  14. Simulation of Swap-Out Reliability For The Advance Photon Source Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borland, M.

    2017-06-01

    The proposed upgrade of the Advanced Photon Source (APS) to a multibend-achromat lattice relies on the use of swap-out injection to accommodate the small dynamic acceptance, allow use of unusual insertion devices, and minimize collective effects at high single-bunch charge. This, combined with the short beam lifetime, will make injector reliability even more important than it is for top-up operation. We used historical data for the APS injector complex to obtain probability distributions for injector up-time and down-time durations. Using these distributions, we simulated several years of swap-out operation for the upgraded lattice for several operatingmodes. The results indicate thatmore » obtaining very high availability of beam in the storage ring will require improvements to injector reliability.« less

  15. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  16. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/Bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  17. Reliability analysis and initial requirements for FC systems and stacks

    NASA Astrophysics Data System (ADS)

    Åström, K.; Fontell, E.; Virtanen, S.

    In the year 2000 Wärtsilä Corporation started an R&D program to develop SOFC systems for CHP applications. The program aims to bring to the market highly efficient, clean and cost competitive fuel cell systems with rated power output in the range of 50-250 kW for distributed generation and marine applications. In the program Wärtsilä focuses on system integration and development. System reliability and availability are key issues determining the competitiveness of the SOFC technology. In Wärtsilä, methods have been implemented for analysing the system in respect to reliability and safety as well as for defining reliability requirements for system components. A fault tree representation is used as the basis for reliability prediction analysis. A dynamic simulation technique has been developed to allow for non-static properties in the fault tree logic modelling. Special emphasis has been placed on reliability analysis of the fuel cell stacks in the system. A method for assessing reliability and critical failure predictability requirements for fuel cell stacks in a system consisting of several stacks has been developed. The method is based on a qualitative model of the stack configuration where each stack can be in a functional, partially failed or critically failed state, each of the states having different failure rates and effects on the system behaviour. The main purpose of the method is to understand the effect of stack reliability, critical failure predictability and operating strategy on the system reliability and availability. An example configuration, consisting of 5 × 5 stacks (series of 5 sets of 5 parallel stacks) is analysed in respect to stack reliability requirements as a function of predictability of critical failures and Weibull shape factor of failure rate distributions.

  18. Development of high-speed rolling-element bearings. A historical and technical perspective

    NASA Technical Reports Server (NTRS)

    Zaretsky, E. V.

    1982-01-01

    Research on large-bore ball and roller bearings for aircraft engines is described. Tapered roller bearings and small-bore bearings are discussed. Temperature capabilities of rolling element bearings for aircraft engines have moved from 450 to 589 K (350 to 600 F) with increased reliability. High bearing speeds to 3 million DN can be achieved with a reliability exceeding that which was common in commercial aircraft. Capabilities of available bearing steels and lubricants were defined and established. Computer programs for the analysis and design of rolling element bearings were developed and experimentally verified. The reported work is a summary of NASA contributions to high performance engine and transmission bearing capabilities.

  19. Evaluation of the efficiency and fault density of software generated by code generators

    NASA Technical Reports Server (NTRS)

    Schreur, Barbara

    1993-01-01

    Flight computers and flight software are used for GN&C (guidance, navigation, and control), engine controllers, and avionics during missions. The software development requires the generation of a considerable amount of code. The engineers who generate the code make mistakes and the generation of a large body of code with high reliability requires considerable time. Computer-aided software engineering (CASE) tools are available which generates code automatically with inputs through graphical interfaces. These tools are referred to as code generators. In theory, code generators could write highly reliable code quickly and inexpensively. The various code generators offer different levels of reliability checking. Some check only the finished product while some allow checking of individual modules and combined sets of modules as well. Considering NASA's requirement for reliability, an in house manually generated code is needed. Furthermore, automatically generated code is reputed to be as efficient as the best manually generated code when executed. In house verification is warranted.

  20. Validation of A Global Hydrological Model

    NASA Astrophysics Data System (ADS)

    Doell, P.; Lehner, B.; Kaspar, F.; Vassolo, S.

    Freshwater availability has been recognized as a global issue, and its consistent quan- tification not only in individual river basins but also at the global scale is required to support the sustainable use of water. The Global Hydrology Model WGHM, which is a submodel of the global water use and availability model WaterGAP 2, computes sur- face runoff, groundwater recharge and river discharge at a spatial resolution of 0.5. WGHM is based on the best global data sets currently available, including a newly developed drainage direction map and a data set of wetlands, lakes and reservoirs. It calculates both natural and actual discharge by simulating the reduction of river discharge by human water consumption (as computed by the water use submodel of WaterGAP 2). WGHM is calibrated against observed discharge at 724 gauging sta- tions (representing about 50% of the global land area) by adjusting a parameter of the soil water balance. It not only computes the long-term average water resources but also water availability indicators that take into account the interannual and seasonal variability of runoff and discharge. The reliability of the model results is assessed by comparing observed and simulated discharges at the calibration stations and at se- lected other stations. We conclude that reliable results can be obtained for basins of more than 20,000 km2. In particular, the 90% reliable monthly discharge is simu- lated well. However, there is the tendency that semi-arid and arid basins are modeled less satisfactorily than humid ones, which is partially due to neglecting river channel losses and evaporation of runoff from small ephemeral ponds in the model. Also, the hydrology of highly developed basins with large artificial storages, basin transfers and irrigation schemes cannot be simulated well. The seasonality of discharge in snow- dominated basins is overestimated by WGHM, and if the snow-dominated basin is uncalibrated, discharge is likely to be underestimated due to the precipitation mea- surement errors. Even though the explicit modeling of wetlands and lakes leads to a much improved modeling of both the vertical water balance and the lateral transport of water, not enough information is included in WGHM to accurately capture the hy- drology of these water bodies. Certainly, the reliability of model results is highest at the locations at which WGHM was calibrated. The validation indicates that reliability for cells inside calibrated basins is satisfactory if the basin is relatively homogeneous. Analyses of the few available stations outside of calibrated basins indicate a reason- ably high model reliability, particularly in humid regions.

  1. The Importance of Human Reliability Analysis in Human Space Flight: Understanding the Risks

    NASA Technical Reports Server (NTRS)

    Hamlin, Teri L.

    2010-01-01

    HRA is a method used to describe, qualitatively and quantitatively, the occurrence of human failures in the operation of complex systems that affect availability and reliability. Modeling human actions with their corresponding failure in a PRA (Probabilistic Risk Assessment) provides a more complete picture of the risk and risk contributions. A high quality HRA can provide valuable information on potential areas for improvement, including training, procedural, equipment design and need for automation.

  2. Physical activity questionnaires for youth: a systematic review of measurement properties.

    PubMed

    Chinapaw, Mai J M; Mokkink, Lidwine B; van Poppel, Mireille N M; van Mechelen, Willem; Terwee, Caroline B

    2010-07-01

    Because of the diversity in available questionnaires, it is not easy for researchers to decide which instrument is most suitable for his or her specific demands. Therefore, we systematically summarized and appraised studies examining measurement properties of self-administered and proxy-reported physical activity (PA) questionnaires in youth. Literature was identified through searching electronic databases (PubMed, EMBASE using 'EMBASE only' and SportDiscus) until May 2009. Studies were included if they reported on the measurement properties of self-administered and proxy-reported PA questionnaires in youth (mean age <18 years) and were published in the English language. Methodological quality and results of included studies was appraised using a standardized checklist (qualitative attributes and measurement properties of PA questionnaires [QAPAQ]). We included 54 manuscripts examining 61 versions of questionnaires. None of the included questionnaires showed both acceptable reliability and validity. Only seven questionnaires received a positive rating for reliability. Reported validity varied, with correlations between PA questionnaires and accelerometers ranging from very low to high (previous day PA recall: correlation coefficient [r] = 0.77). In general, PA questionnaires for adolescents correlated better with accelerometer scores than did those for children. From this systematic review, we conclude that no questionnaires were available with both acceptable reliability and validity. Considerably more high-quality research is required to examine the validity and reliability of promising PA questionnaires for youth.

  3. High-reliability gas-turbine combined-cycle development program: Phase II, Volume 3. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hecht, K.G.; Sanderson, R.A.; Smith, M.J.

    This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. The power plant was addressed in three areas: (1) the gas turbine, (2) the gas turbine ancillaries, and (3) the balance of plant including the steam turbine generator. To achieve the program goals, a gasmore » turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and manual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-h EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricty compared to present market offerings.« less

  4. Reliability assessment and improvement for a fast corrector power supply in TPS

    NASA Astrophysics Data System (ADS)

    Liu, Kuo-Bin; Liu, Chen-Yao; Wang, Bao-Sheng; Wong, Yong Seng

    2018-07-01

    Fast Orbit Feedback System (FOFB) can be installed in a synchrotron light source to eliminate undesired disturbances and to improve the stability of beam orbit. The design and implementation of an accurate and reliable Fast Corrector Power Supply (FCPS) is essential to realize the effectiveness and availability of the FOFB. A reliability assessment for the FCPSs in the FOFB of Taiwan Photon Source (TPS) considering MOSFETs' temperatures is represented in this paper. The FCPS is composed of a full-bridge topology and a low-pass filter. A Hybrid Pulse Width Modulation (HPWM) requiring two MOSFETs in the full-bridge circuit to be operated at high frequency and the other two be operated at the output frequency is adopted to control the implemented FCPS. Due the characteristic of HPWM, the conduction loss and switching loss of each MOSFET in the FCPS is not same. Two of the MOSFETs in the full-bridge circuit will suffer higher temperatures and therefore the circuit reliability of FCPS is reduced. A Modified PWM Scheme (MPWMS) designed to average MOSFETs' temperatures and to improve circuit reliability is proposed in this paper. Experimental results measure the MOSFETs' temperatures of FCPS controlled by the HPWM and the proposed MPWMS. The reliability indices under different PWM controls are then assessed. From the experimental results, it can be observed that the reliability of FCPS using the proposed MPWMS can be improved because the MOSFETs' temperatures are closer. Since the reliability of FCPS can be enhanced, the availability of FOFB can also be improved.

  5. High Cholesterol and Complementary Health Practices: What the Science Says

    MedlinePlus

    ... in flaxseed and flaxseed oil) may benefit people with heart disease. But not enough reliable data are available to ... conventional oral medications or other dietary supplements. ... complementary health researchers, and disseminating authoritative information to ...

  6. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 1: HARP introduction and user's guide

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.

  7. Constraining uncertainties in water supply reliability in a tropical data scarce basin

    NASA Astrophysics Data System (ADS)

    Kaune, Alexander; Werner, Micha; Rodriguez, Erasmo; de Fraiture, Charlotte

    2015-04-01

    Assessing the water supply reliability in river basins is essential for adequate planning and development of irrigated agriculture and urban water systems. In many cases hydrological models are applied to determine the surface water availability in river basins. However, surface water availability and variability is often not appropriately quantified due to epistemic uncertainties, leading to water supply insecurity. The objective of this research is to determine the water supply reliability in order to support planning and development of irrigated agriculture in a tropical, data scarce environment. The approach proposed uses a simple hydrological model, but explicitly includes model parameter uncertainty. A transboundary river basin in the tropical region of Colombia and Venezuela with an approximately area of 2100 km² was selected as a case study. The Budyko hydrological framework was extended to consider climatological input variability and model parameter uncertainty, and through this the surface water reliability to satisfy the irrigation and urban demand was estimated. This provides a spatial estimate of the water supply reliability across the basin. For the middle basin the reliability was found to be less than 30% for most of the months when the water is extracted from an upstream source. Conversely, the monthly water supply reliability was high (r>98%) in the lower basin irrigation areas when water was withdrawn from a source located further downstream. Including model parameter uncertainty provides a complete estimate of the water supply reliability, but that estimate is influenced by the uncertainty in the model. Reducing the uncertainty in the model through improved data and perhaps improved model structure will improve the estimate of the water supply reliability allowing better planning of irrigated agriculture and dependable water allocation decisions.

  8. Reliability and Maintainability Analysis of a High Air Pressure Compressor Facility

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.; Ring, Robert W.; Cole, Stuart K.

    2013-01-01

    This paper discusses a Reliability, Availability, and Maintainability (RAM) independent assessment conducted to support the refurbishment of the Compressor Station at the NASA Langley Research Center (LaRC). The paper discusses the methodologies used by the assessment team to derive the repair by replacement (RR) strategies to improve the reliability and availability of the Compressor Station (Ref.1). This includes a RAPTOR simulation model that was used to generate the statistical data analysis needed to derive a 15-year investment plan to support the refurbishment of the facility. To summarize, study results clearly indicate that the air compressors are well past their design life. The major failures of Compressors indicate that significant latent failure causes are present. Given the occurrence of these high-cost failures following compressor overhauls, future major failures should be anticipated if compressors are not replaced. Given the results from the RR analysis, the study team recommended a compressor replacement strategy. Based on the data analysis, the RR strategy will lead to sustainable operations through significant improvements in reliability, availability, and the probability of meeting the air demand with acceptable investment cost that should translate, in the long run, into major cost savings. For example, the probability of meeting air demand improved from 79.7 percent for the Base Case to 97.3 percent. Expressed in terms of a reduction in the probability of failing to meet demand (1 in 5 days to 1 in 37 days), the improvement is about 700 percent. Similarly, compressor replacement improved the operational availability of the facility from 97.5 percent to 99.8 percent. Expressed in terms of a reduction in system unavailability (1 in 40 to 1 in 500), the improvement is better than 1000 percent (an order of magnitude improvement). It is worthy to note that the methodologies, tools, and techniques used in the LaRC study can be used to evaluate similar high value equipment components and facilities. Also, lessons learned in data collection and maintenance practices derived from the observations, findings, and recommendations of the study are extremely important in the evaluation and sustainment of new compressor facilities.

  9. Understanding climate-hydrologic-human interactions to guide groundwater model development for Southern High Plains

    USDA-ARS?s Scientific Manuscript database

    The Ogallala aquifer is the only reliable source of water in the southern High Plains (SHP) region of Texas, New Mexico and Oklahoma. Groundwater availability has fostered a strong agricultural economy that has a significant impact on global food security. Groundwater models that not only capture ...

  10. REDItools: high-throughput RNA editing detection made easy.

    PubMed

    Picardi, Ernesto; Pesole, Graziano

    2013-07-15

    The reliable detection of RNA editing sites from massive sequencing data remains challenging and, although several methodologies have been proposed, no computational tools have been released to date. Here, we introduce REDItools a suite of python scripts to perform high-throughput investigation of RNA editing using next-generation sequencing data. REDItools are in python programming language and freely available at http://code.google.com/p/reditools/. ernesto.picardi@uniba.it or graziano.pesole@uniba.it Supplementary data are available at Bioinformatics online.

  11. Implementing eco friendly highly reliable upload feature using multi 3G service

    NASA Astrophysics Data System (ADS)

    Tanutama, Lukas; Wijaya, Rico

    2017-12-01

    The current trend of eco friendly Internet access is preferred. In this research the understanding of eco friendly is minimum power consumption. The devices that are selected have operationally low power consumption and normally have no power consumption as they are hibernating during idle state. To have the reliability a router of a router that has internal load balancing feature will provide the improvement of previous research on multi 3G services for broadband lines. Previous studies emphasized on accessing and downloading information files from Public Cloud residing Web Servers. The demand is not only for speed but high reliability of access as well. High reliability will mean mitigating both direct and indirect high cost due to repeated attempts of uploading and downloading the large files. Nomadic and mobile computer users need viable solution. Following solution for downloading information has been proposed and tested. The solution is promising. The result is now extended to providing reliable access line by means of redundancy and automatic reconfiguration for uploading and downloading large information files to a Web Server in the Cloud. The technique is taking advantage of internal load balancing feature to provision a redundant line acting as a backup line. A router that has the ability to provide load balancing to several WAN lines is chosen. The WAN lines are constructed using multiple 3G lines. The router supports the accessing Internet with more than one 3G access line which increases the reliability and availability of the Internet access as the second line immediately takes over if the first line is disturbed.

  12. Effect of reflective p-type ohmic contact on thermal reliability of vertical InGaN/GaN LEDs

    NASA Astrophysics Data System (ADS)

    Son, Jun Ho; Song, Yang Hee; Kim, Buem Joon; Lee, Jong-Lam

    2014-11-01

    We report on the enhanced thermal reliability of vertical-LEDs (VLEDs) using novel reflective p-type ohmic contacts with good thermal stability. The reflective p-type ohmic contacts with Ni/Ag-Cu alloy multi-layer structure shows low contact resistivity, as low as 9.3 × 10-6 Ωcm2, and high reflectance of 86% after annealing at 450°C. The V-LEDs with Ni/Ag-Cu alloy multi-layer structure show good thermal reliability with stress time at 300°C in air ambient. The improved thermal stability of the reflective ohmic contacts to p-type GaN is believed to play a critical role in the thermal reliability of V-LEDs. [Figure not available: see fulltext.

  13. Reliability Impacts in Life Support Architecture and Technology Selection

    NASA Technical Reports Server (NTRS)

    Lange, Kevin E.; Anderson, Molly S.

    2011-01-01

    Equivalent System Mass (ESM) and reliability estimates were performed for different life support architectures based primarily on International Space Station (ISS) technologies. The analysis was applied to a hypothetical 1-year deep-space mission. High-level fault trees were initially developed relating loss of life support functionality to the Loss of Crew (LOC) top event. System reliability was then expressed as the complement (nonoccurrence) this event and was increased through the addition of redundancy and spares, which added to the ESM. The reliability analysis assumed constant failure rates and used current projected values of the Mean Time Between Failures (MTBF) from an ISS database where available. Results were obtained showing the dependence of ESM on system reliability for each architecture. Although the analysis employed numerous simplifications and many of the input parameters are considered to have high uncertainty, the results strongly suggest that achieving necessary reliabilities for deep-space missions will add substantially to the life support system mass. As a point of reference, the reliability for a single-string architecture using the most regenerative combination of ISS technologies without unscheduled replacement spares was estimated to be less than 1%. The results also demonstrate how adding technologies in a serial manner to increase system closure forces the reliability of other life support technologies to increase in order to meet the system reliability requirement. This increase in reliability results in increased mass for multiple technologies through the need for additional spares. Alternative parallel architecture approaches and approaches with the potential to do more with less are discussed. The tall poles in life support ESM are also reexamined in light of estimated reliability impacts.

  14. Cockpit automation

    NASA Technical Reports Server (NTRS)

    Wiener, Earl L.

    1988-01-01

    The aims and methods of aircraft cockpit automation are reviewed from a human-factors perspective. Consideration is given to the mixed pilot reception of increased automation, government concern with the safety and reliability of highly automated aircraft, the formal definition of automation, and the ground-proximity warning system and accidents involving controlled flight into terrain. The factors motivating automation include technology availability; safety; economy, reliability, and maintenance; workload reduction and two-pilot certification; more accurate maneuvering and navigation; display flexibility; economy of cockpit space; and military requirements.

  15. Reliability-Productivity Curve, a Tool for Adaptation Measures Identification

    NASA Astrophysics Data System (ADS)

    Chávez-Jiménez, A.; Granados, A.; Garrote, L. M.

    2015-12-01

    Due to climate change effects, water scarcity problems would intensify in several regions. These problems are going to impact negatively in the water low-priority demands, since these will be reduced in favor of those with high-priority. An example would be the reduction of agriculture water resources in favor of the urban ones. Then, it is important the evaluation of adaptation measures for a better water resources management. An important tool to face this challenge is the economic valuation of the water demands' impact within a water resources system. In agriculture this valuation is usually performed through the water productivity evaluation. The water productivity evaluation requires detailed information regarding the different crops like the applied technology, the agricultural supplies management, the water availability, etc. This is a restriction for an evaluation at basin scale due to the difficulty of gathers this level of detailed information. Besides, only the water availability is taken into account, but not the period when the water is distributed (i.e. water resources reliability). Water resources reliability is one of the most important variables in water resources management. This research proposes a methodology to determine the agriculture water productivity, using as variables the crops information, the crops price, the water resources availability, and the water resources reliability, at a basin scale. This methodology would allow identifying general water resources adaptation measures, providing the basis for further detailed studies in critical regions.

  16. ETARA PC version 3.3 user's guide: Reliability, availability, maintainability simulation model

    NASA Technical Reports Server (NTRS)

    Hoffman, David J.; Viterna, Larry A.

    1991-01-01

    A user's manual describing an interactive, menu-driven, personal computer based Monte Carlo reliability, availability, and maintainability simulation program called event time availability reliability (ETARA) is discussed. Given a reliability block diagram representation of a system, ETARA simulates the behavior of the system over a specified period of time using Monte Carlo methods to generate block failure and repair intervals as a function of exponential and/or Weibull distributions. Availability parameters such as equivalent availability, state availability (percentage of time as a particular output state capability), continuous state duration and number of state occurrences can be calculated. Initial spares allotment and spares replenishment on a resupply cycle can be simulated. The number of block failures are tabulated both individually and by block type, as well as total downtime, repair time, and time waiting for spares. Also, maintenance man-hours per year and system reliability, with or without repair, at or above a particular output capability can be calculated over a cumulative period of time or at specific points in time.

  17. Estimating the Reliability of Electronic Parts in High Radiation Fields

    NASA Technical Reports Server (NTRS)

    Everline, Chester; Clark, Karla; Man, Guy; Rasmussen, Robert; Johnston, Allan; Kohlhase, Charles; Paulos, Todd

    2008-01-01

    Radiation effects on materials and electronic parts constrain the lifetime of flight systems visiting Europa. Understanding mission lifetime limits is critical to the design and planning of such a mission. Therefore, the operational aspects of radiation dose are a mission success issue. To predict and manage mission lifetime in a high radiation environment, system engineers need capable tools to trade radiation design choices against system design and reliability, and science achievements. Conventional tools and approaches provided past missions with conservative designs without the ability to predict their lifetime beyond the baseline mission.This paper describes a more systematic approach to understanding spacecraft design margin, allowing better prediction of spacecraft lifetime. This is possible because of newly available electronic parts radiation effects statistics and an enhanced spacecraft system reliability methodology. This new approach can be used in conjunction with traditional approaches for mission design. This paper describes the fundamentals of the new methodology.

  18. Improving the reliability of inverter-based welding machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schiedermayer, M.

    1997-02-01

    Although inverter-based welding power sources have been available since the late 1980s, many people hesitated to purchase them because of reliability issues. Unfortunately, their hesitancy had a basis, until now. Recent improvements give some inverters a reliability level that approaches that of traditional, transformer-based industrial welding machines, which have a failure rate of about 1%. Acceptance of inverter-based welding machines is important because, for many welding applications, they provide capabilities that solid-state, transformer-based machines cannot deliver. These advantages include enhanced pulsed gas metal arc welding (GMAW-P), lightweight portability, an ultrastable arc, and energy efficiency--all while producing highly aesthetic weld beadsmore » and delivering multiprocess capabilities.« less

  19. A Quantitative Socio-hydrological Characterization of Water Security in Large-Scale Irrigation Systems

    NASA Astrophysics Data System (ADS)

    Siddiqi, A.; Muhammad, A.; Wescoat, J. L., Jr.

    2017-12-01

    Large-scale, legacy canal systems, such as the irrigation infrastructure in the Indus Basin in Punjab, Pakistan, have been primarily conceived, constructed, and operated with a techno-centric approach. The emerging socio-hydrological approaches provide a new lens for studying such systems to potentially identify fresh insights for addressing contemporary challenges of water security. In this work, using the partial definition of water security as "the reliable availability of an acceptable quantity and quality of water", supply reliability is construed as a partial measure of water security in irrigation systems. A set of metrics are used to quantitatively study reliability of surface supply in the canal systems of Punjab, Pakistan using an extensive dataset of 10-daily surface water deliveries over a decade (2007-2016) and of high frequency (10-minute) flow measurements over one year. The reliability quantification is based on comparison of actual deliveries and entitlements, which are a combination of hydrological and social constructs. The socio-hydrological lens highlights critical issues of how flows are measured, monitored, perceived, and experienced from the perspective of operators (government officials) and users (famers). The analysis reveals varying levels of reliability (and by extension security) of supply when data is examined across multiple temporal and spatial scales. The results shed new light on evolution of water security (as partially measured by supply reliability) for surface irrigation in the Punjab province of Pakistan and demonstrate that "information security" (defined as reliable availability of sufficiently detailed data) is vital for enabling water security. It is found that forecasting and management (that are social processes) lead to differences between entitlements and actual deliveries, and there is significant potential to positively affect supply reliability through interventions in the social realm.

  20. Reliability and Availability Evaluation Program Manual.

    DTIC Science & Technology

    1982-11-01

    research and development. The manual’s purpose was to provide a practical method for making reliability measurements, measurements directly related to... Research , Development, Test and Evaluation. RMA Reliability, Maintainability and Availability. R&R Repair and Refurbishment, Repair and Replacement, etc...length. phenomena such as mechanical wear and A number of researchers in the reliability chemical deterioration. Maintenance should field 14-pages 402

  1. Design of fuel cell powered data centers for sufficient reliability and availability

    NASA Astrophysics Data System (ADS)

    Ritchie, Alexa J.; Brouwer, Jacob

    2018-04-01

    It is challenging to design a sufficiently reliable fuel cell electrical system for use in data centers, which require 99.9999% uptime. Such a system could lower emissions and increase data center efficiency, but the reliability and availability of such a system must be analyzed and understood. Currently, extensive backup equipment is used to ensure electricity availability. The proposed design alternative uses multiple fuel cell systems each supporting a small number of servers to eliminate backup power equipment provided the fuel cell design has sufficient reliability and availability. Potential system designs are explored for the entire data center and for individual fuel cells. Reliability block diagram analysis of the fuel cell systems was accomplished to understand the reliability of the systems without repair or redundant technologies. From this analysis, it was apparent that redundant components would be necessary. A program was written in MATLAB to show that the desired system reliability could be achieved by a combination of parallel components, regardless of the number of additional components needed. Having shown that the desired reliability was achievable through some combination of components, a dynamic programming analysis was undertaken to assess the ideal allocation of parallel components.

  2. Material Selection for Cable Gland to Improved Reliability of the High-hazard Industries

    NASA Astrophysics Data System (ADS)

    Vashchuk, S. P.; Slobodyan, S. M.; Deeva, V. S.; Vashchuk, D. S.

    2018-01-01

    The sealed cable glands (SCG) are available to ensure safest connection sheathed single wire for the hazard production facility (nuclear power plant and others) the same as pilot cable, control cables, radio-frequency cables et al. In this paper, we investigate the specifics of the material selection of SCG with the express aim of hazardous man-made facility. We discuss the safe working conditions for cable glands. The research indicates the sintering powdered metals cables provide the reliability growth due to their properties. A number of studies have demonstrated the verification of material selection. On the face of it, we make findings indicating that double glazed sealed units could enhance reliability. We had evaluated sample reliability under fire conditions, seismic load, and pressure containment failure. We used the samples mineral insulated thermocouple cable.

  3. Human Reliability and the Cost of Doing Business

    NASA Technical Reports Server (NTRS)

    DeMott, Diana

    2014-01-01

    Most businesses recognize that people will make mistakes and assume errors are just part of the cost of doing business, but does it need to be? Companies with high risk, or major consequences, should consider the effect of human error. In a variety of industries, Human Errors have caused costly failures and workplace injuries. These have included: airline mishaps, medical malpractice, administration of medication and major oil spills have all been blamed on human error. A technique to mitigate or even eliminate some of these costly human errors is the use of Human Reliability Analysis (HRA). Various methodologies are available to perform Human Reliability Assessments that range from identifying the most likely areas for concern to detailed assessments with human error failure probabilities calculated. Which methodology to use would be based on a variety of factors that would include: 1) how people react and act in different industries, and differing expectations based on industries standards, 2) factors that influence how the human errors could occur such as tasks, tools, environment, workplace, support, training and procedure, 3) type and availability of data and 4) how the industry views risk & reliability influences ( types of emergencies, contingencies and routine tasks versus cost based concerns). The Human Reliability Assessments should be the first step to reduce, mitigate or eliminate the costly mistakes or catastrophic failures. Using Human Reliability techniques to identify and classify human error risks allows a company more opportunities to mitigate or eliminate these risks and prevent costly failures.

  4. Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners.

    PubMed

    Borges, Nattai R; Driller, Matthew W

    2016-08-01

    Borges, NR and Driller, MW. Wearable lactate threshold predicting device is valid and reliable in runners. J Strength Cond Res 30(8): 2212-2218, 2016-A commercially available device claiming to be the world's first wearable lactate threshold predicting device (WLT), using near-infrared LED technology, has entered the market. The aim of this study was to determine the levels of agreement between the WLT-derived lactate threshold workload and traditional methods of lactate threshold (LT) calculation and the interdevice and intradevice reliability of the WLT. Fourteen (7 male, 7 female; mean ± SD; age: 18-45 years, height: 169 ± 9 cm, mass: 67 ± 13 kg, V[Combining Dot Above]O2max: 53 ± 9 ml·kg·min) subjects ranging from recreationally active to highly trained athletes completed an incremental exercise test to exhaustion on a treadmill. Blood lactate samples were taken at the end of each 3-minute stage during the test to determine lactate threshold using 5 traditional methods from blood lactate analysis which were then compared against the WLT predicted value. In a subset of the population (n = 12), repeat trials were performed to determine both inter-reliability and intrareliability of the WLT device. Intraclass correlation coefficient (ICC) found high to very high agreement between the WLT and traditional methods (ICC > 0.80), with TEMs and mean differences ranging between 3.9-10.2% and 1.3-9.4%. Both interdevice and intradevice reliability resulted in highly reproducible and comparable results (CV < 1.2%, TEM <0.2 km·h, ICC > 0.97). This study suggests that the WLT is a practical, reliable, and noninvasive tool for use in predicting LT in runners.

  5. Bidirectional dc-to-dc Power Converter

    NASA Technical Reports Server (NTRS)

    Griesbach, C. R.

    1986-01-01

    Solid-state, series-resonant converter uses high-voltage thyristors. Converter used either to convert high-voltage, low-current dc power to lowvoltage, high current power or reverse. Taking advantage of newly-available high-voltage thyristors to provide better reliability and efficiency than traditional converters that use vacuum tubes as power switches. New converter essentially maintenance free and provides greatly increased mean time between failures. Attractive in industrial applications whether or not bidirectional capability is required.

  6. Handling of Atomic Data

    NASA Astrophysics Data System (ADS)

    Rauch, T.; Deetjen, J. L.

    2003-01-01

    State-of-the-art NLTE model atmosphere codes have arrived at a high level of ``numerical'' sophistication and are an adequate tool to analyze the available high-quality spectra from the infrared to the X-ray wavelength range. The computational capacities allow the calculation which include all elements from hydrogen up to the iron group and the lack of reliable atomic data has become a crucial problem for further progress. We summarize briefly the available sources of atomic data and how these are implemented in the Tübingen Model Atmosphere Package (TMAP).

  7. The reliability of a modified Kalamazoo Consensus Statement Checklist for assessing the communication skills of multidisciplinary clinicians in the simulated environment.

    PubMed

    Peterson, Eleanor B; Calhoun, Aaron W; Rider, Elizabeth A

    2014-09-01

    With increased recognition of the importance of sound communication skills and communication skills education, reliable assessment tools are essential. This study reports on the psychometric properties of an assessment tool based on the Kalamazoo Consensus Statement Essential Elements Communication Checklist. The Gap-Kalamazoo Communication Skills Assessment Form (GKCSAF), a modified version of an existing communication skills assessment tool, the Kalamazoo Essential Elements Communication Checklist-Adapted, was used to assess learners in a multidisciplinary, simulation-based communication skills educational program using multiple raters. 118 simulated conversations were available for analysis. Internal consistency and inter-rater reliability were determined by calculating a Cronbach's alpha score and intra-class correlation coefficients (ICC), respectively. The GKCSAF demonstrated high internal consistency with a Cronbach's alpha score of 0.844 (faculty raters) and 0.880 (peer observer raters), and high inter-rater reliability with an ICC of 0.830 (faculty raters) and 0.89 (peer observer raters). The Gap-Kalamazoo Communication Skills Assessment Form is a reliable method of assessing the communication skills of multidisciplinary learners using multi-rater methods within the learning environment. The Gap-Kalamazoo Communication Skills Assessment Form can be used by educational programs that wish to implement a reliable assessment and feedback system for a variety of learners. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Western Grid Can Handle High Renewables in Challenging Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-11-01

    Fact sheet outlining the key findings of Phase 3 of the Western Wind and Solar Integration Study (WWSIS-3). NREL and GE find that with good system planning, sound engineering practices, and commercially available technologies, the Western grid can maintain reliability and stability during the crucial first minute after grid disturbances with high penetrations of wind and solar power.

  9. HiRel - Reliability/availability integrated workstation tool

    NASA Technical Reports Server (NTRS)

    Bavuso, Salvatore J.; Dugan, Joanne B.

    1992-01-01

    The HiRel software tool is described and demonstrated by application to the mission avionics subsystem of the Advanced System Integration Demonstrations (ASID) system that utilizes the PAVE PILLAR approach. HiRel marks another accomplishment toward the goal of producing a totally integrated computer-aided design (CAD) workstation design capability. Since a reliability engineer generally represents a reliability model graphically before it can be solved, the use of a graphical input description language increases productivity and decreases the incidence of error. The graphical postprocessor module HARPO makes it possible for reliability engineers to quickly analyze huge amounts of reliability/availability data to observe trends due to exploratory design changes. The addition of several powerful HARP modeling engines provides the user with a reliability/availability modeling capability for a wide range of system applications all integrated under a common interactive graphical input-output capability.

  10. Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.

    PubMed

    Luteberget, Live S; Holme, Benjamin R; Spencer, Matt

    2018-04-01

    To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.

  11. Reliability and Concurrent Validity of the Narrow Path Walking Test in Persons With Multiple Sclerosis.

    PubMed

    Rosenblum, Uri; Melzer, Itshak

    2017-01-01

    About 90% of people with multiple sclerosis (PwMS) have gait instability and 50% fall. Reliable and clinically feasible methods of gait instability assessment are needed. The study investigated the reliability and validity of the Narrow Path Walking Test (NPWT) under single-task (ST) and dual-task (DT) conditions for PwMS. Thirty PwMS performed the NPWT on 2 different occasions, a week apart. Number of Steps, Trial Time, Trial Velocity, Step Length, Number of Step Errors, Number of Cognitive Task Errors, and Number of Balance Losses were measured. Intraclass correlation coefficients (ICC2,1) were calculated from the average values of NPWT parameters. Absolute reliability was quantified from standard error of measurement (SEM) and smallest real difference (SRD). Concurrent validity of NPWT with Functional Reach Test, Four Square Step Test (FSST), 12-item Multiple Sclerosis Walking Scale (MSWS-12), and 2 Minute Walking Test (2MWT) was determined using partial correlations. Intraclass correlation coefficients (ICCs) for most NPWT parameters during ST and DT ranged from 0.46-0.94 and 0.55-0.95, respectively. The highest relative reliability was found for Number of Step Errors (ICC = 0.94 and 0.93, for ST and DT, respectively) and Trial Velocity (ICC = 0.83 and 0.86, for ST and DT, respectively). Absolute reliability was high for Number of Step Errors in ST (SEM % = 19.53%) and DT (SEM % = 18.14%) and low for Trial Velocity in ST (SEM % = 6.88%) and DT (SEM % = 7.29%). Significant correlations for Number of Step Errors and Trial Velocity were found with FSST, MSWS-12, and 2MWT. In persons with PwMS performing the NPWT, Number of Step Errors and Trial Velocity were highly reliable parameters. Based on correlations with other measures of gait instability, Number of Step Errors was the most valid parameter of dynamic balance under the conditions of our test.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, available at: http://links.lww.com/JNPT/A159).

  12. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    NASA Astrophysics Data System (ADS)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  13. Added Value of Reliability to a Microgrid: Simulations of Three California Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marnay, Chris; Lai, Judy; Stadler, Michael

    The Distributed Energy Resources Customer Adoption Model is used to estimate the value an Oakland nursing home, a Riverside high school, and a Sunnyvale data center would need to put on higher electricity service reliability for them to adopt a Consortium for Electric Reliability Technology Solutions Microgrid (CM) based on economics alone. A fraction of each building's load is deemed critical based on its mission, and the added cost of CM capability to meet it added to on-site generation options. The three sites are analyzed with various resources available as microgrid components. Results show that the value placed on highermore » reliability often does not have to be significant for CM to appear attractive, about 25 $/kWcdota and up, but the carbon footprint consequences are mixed because storage is often used to shift cheaper off-peak electricity to use during afternoon hours in competition with the solar sources.« less

  14. Adaptation and Validation of a Nutrition Environment Measures Survey for University Grab-and-Go Establishments.

    PubMed

    Lo, Brian K C; Minaker, Leia; Chan, Alicia N T; Hrgetic, Jessica; Mah, Catherine L

    2016-03-01

    To adapt and validate a survey instrument to assess the nutrition environment of grab-and-go establishments at a university campus. A version of the Nutrition Environment Measures Survey for grab-and-go establishments (NEMS-GG) was adapted from existing NEMS instruments and tested for reliability and validity through a cross-sectional assessment of the grab-and-go establishments at the University of Toronto. Product availability, price, and presence of nutrition information were evaluated. Cohen's kappa coefficient and intra-class correlation coefficients (ICC) were assessed for inter-rater reliability, and construct validity was assessed using the known-groups comparison method (via store scores). Fifteen grab-and-go establishments were assessed. Inter-rater reliability was high with an almost perfect agreement for availability (mean κ = 0.995) and store scores (ICC = 0.999). The tool demonstrated good face and construct validity. About half of the venues carried fruit and vegetables (46.7% and 53.3%, respectively). Regular and healthier entrée items were generally the same price. Healthier grains were cheaper than regular options. Six establishments displayed nutrition information. Establishments operated by the university's Food Services consistently scored the highest across all food premise types for nutrition signage, availability, and cost of healthier options. Health promotion strategies are needed to address availability and variety of healthier grab-and-go options in university settings.

  15. Age-Related Differences in Test-Retest Reliability in Resting-State Brain Functional Connectivity

    PubMed Central

    Song, Jie; Desphande, Alok S.; Meier, Timothy B.; Tudorascu, Dana L.; Vergun, Svyatoslav; Nair, Veena A.; Biswal, Bharat B.; Meyerand, Mary E.; Birn, Rasmus M.; Bellec, Pierre; Prabhakaran, Vivek

    2012-01-01

    Resting-state functional MRI (rs-fMRI) has emerged as a powerful tool for investigating brain functional connectivity (FC). Research in recent years has focused on assessing the reliability of FC across younger subjects within and between scan-sessions. Test-retest reliability in resting-state functional connectivity (RSFC) has not yet been examined in older adults. In this study, we investigated age-related differences in reliability and stability of RSFC across scans. In addition, we examined how global signal regression (GSR) affects RSFC reliability and stability. Three separate resting-state scans from 29 younger adults (18–35 yrs) and 26 older adults (55–85 yrs) were obtained from the International Consortium for Brain Mapping (ICBM) dataset made publically available as part of the 1000 Functional Connectomes project www.nitrc.org/projects/fcon_1000. 92 regions of interest (ROIs) with 5 cubic mm radius, derived from the default, cingulo-opercular, fronto-parietal and sensorimotor networks, were previously defined based on a recent study. Mean time series were extracted from each of the 92 ROIs from each scan and three matrices of z-transformed correlation coefficients were created for each subject, which were then used for evaluation of multi-scan reliability and stability. The young group showed higher reliability of RSFC than the old group with GSR (p-value = 0.028) and without GSR (p-value <0.001). Both groups showed a high degree of multi-scan stability of RSFC and no significant differences were found between groups. By comparing the test-retest reliability of RSFC with and without GSR across scans, we found significantly higher proportion of reliable connections in both groups without GSR, but decreased stability. Our results suggest that aging is associated with reduced reliability of RSFC which itself is highly stable within-subject across scans for both groups, and that GSR reduces the overall reliability but increases the stability in both age groups and could potentially alter group differences of RSFC. PMID:23227153

  16. A study on reliability of power customer in distribution network

    NASA Astrophysics Data System (ADS)

    Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin

    2017-05-01

    The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.

  17. UV-fibers: two decades of improvements for new applications

    NASA Astrophysics Data System (ADS)

    Klein, Karl-Friedrich; Khalilov, Valery K.

    2015-03-01

    Multimode UV-fibers with high-OH synthetic silica core and F-doped silica cladding have been available for over 40 years. At the beginning, the spectral UV-range above 250 nm wavelength was commonly used, because the generation of UV-absorbing defect centers prevented reliable light transfer below 250 nm; even light from a low-power broadband deuterium-lamp was sufficient to damage these UV-fibers of the 1st generation. However, even then, applications in the field of spectroscopy, laser light delivery, sensors and process control were discussed and improvements of fiber quality in this very interesting UVC range required by researchers and industrial end-users. Starting in 1993 with hydrogen-loaded fibers, further modification in preform and fiber manufacturing including additional fiber treatments lead to currently available hydrogen-free UV-fiber (4th generation) with significantly improved stability in the UVC, enabling routine use of optical fibers in this field. In addition to the UV-fiber improvements, some selected UV fiber-optic applications using broadband deuterium-lamps will be discussed. Finally, there is still room for further improvements, especially in combination with newly available pulsed UV light sources, which are low-cost, small sized and highly reliable.

  18. Implementation of Integrated System Fault Management Capability

    NASA Technical Reports Server (NTRS)

    Figueroa, Fernando; Schmalzel, John; Morris, Jon; Smith, Harvey; Turowski, Mark

    2008-01-01

    Fault Management to support rocket engine test mission with highly reliable and accurate measurements; while improving availability and lifecycle costs. CORE ELEMENTS: Architecture, taxonomy, and ontology (ATO) for DIaK management. Intelligent Sensor Processes; Intelligent Element Processes; Intelligent Controllers; Intelligent Subsystem Processes; Intelligent System Processes; Intelligent Component Processes.

  19. Independent predictors of reliability between full time employee-dependent acquisition of functional outcomes compared to non-full time employee-dependent methodologies: a prospective single institutional study.

    PubMed

    Adogwa, Owoicho; Elsamadicy, Aladine A; Cheng, Joseph; Bagley, Carlos

    2016-03-01

    The prospective acquisition of reliable patient-reported outcomes (PROs) measures demonstrating the effectiveness of spine surgery, or lack thereof, remains a challenge. The aims of this study are to compare the reliability of functional outcomes metrics obtained using full time employee (FTE) vs. non-FTE-dependent methodologies and to determine the independent predictors of response reliability using non FTE-dependent methodologies. One hundred and nineteen adult patients (male: 65, female: 54) undergoing one- and two-level lumbar fusions at Duke University Medical Center were enrolled in this prospective study. Enrollment criteria included available demographic, clinical and baseline functional outcomes data. All patients were administered two similar sets of baseline questionnaires-(I) phone interviews (FTE-dependent) and (II) hardcopy in clinic (patient self-survey, non-FTE-dependent). All patients had at least a two-week washout period between phone interviews and in-clinic self-surveys to minimize effect of recall. Questionnaires included Oswestry disability index (ODI) and Visual Analog Back and Leg Pain Scale (VAS-BP/LP). Reliability was assessed by the degree to which patient responses to baseline questionnaires differed between both time points. About 26.89% had a history an anxiety disorder and 28.57% reported a history of depression. At least 97.47% of patients had a High School Diploma or GED, with 49.57% attaining a 4-year college degree or post-graduate degree. 29.94% reported full-time employment and 14.28% were on disability. There was a very high correlation between baseline PRO's data captured between FTE-dependent compared to non-FTE-dependent methodologies (r=0.89). In a multivariate logistic regression model, the absence of anxiety and depression, higher levels of education (college or greater) and full-time employment, were independently associated with high response reliability using non-FTE-dependent methodologies. Our study suggests that capturing health-related quality of life data using non-FTE-dependent methodologies is highly reliable and maybe a more cost-effective alternative. Well-educated patients who are employed full-time appear to be the most reliable.

  20. Propagation Impact on Modern HF (High Frequency) Communications System Design

    DTIC Science & Technology

    1986-03-01

    received SNR is maximised and interference avoided. As a general principle, system availability and reliability should be improved by the use of...LECTURE SERIES No. 145 propagation Impact on Modern HF Communications System Design. NORTH ATLANTIC TREATY ORGANIZATION gS ^, DISTRIBUTION ...civil and military communities for high frequency communications. It will discuss concepts of real time channel evaluation , system design, as well as

  1. The Wartegg Zeichen Test: a literature overview and a meta-analysis of reliability and validity.

    PubMed

    Soilevuo Grønnerød, Jarna; Grønnerød, Cato

    2012-06-01

    All available studies on the Wartegg Zeichen Test (WZT; Wartegg, 1939) were collected and evaluated through a literature overview and a meta-analysis. The literature overview shows that the history of the WZT reflects the geographical and language-based processes of marginalization where relatively isolated traditions have lived and vanished in different parts of the world. The meta-analytic review indicates a high average interscorer reliability of rw = .74 and high validity effect size for studies with clear hypotheses of rw = .33. Although the results were strong, we conclude that the WZT research has not been able to establish cumulative knowledge of the method because of the isolation of research traditions. (c) 2012 APA, all rights reserved

  2. An Integrated Fault Tolerant Robotic Controller System for High Reliability and Safety

    NASA Technical Reports Server (NTRS)

    Marzwell, Neville I.; Tso, Kam S.; Hecht, Myron

    1994-01-01

    This paper describes the concepts and features of a fault-tolerant intelligent robotic control system being developed for applications that require high dependability (reliability, availability, and safety). The system consists of two major elements: a fault-tolerant controller and an operator workstation. The fault-tolerant controller uses a strategy which allows for detection and recovery of hardware, operating system, and application software failures.The fault-tolerant controller can be used by itself in a wide variety of applications in industry, process control, and communications. The controller in combination with the operator workstation can be applied to robotic applications such as spaceborne extravehicular activities, hazardous materials handling, inspection and maintenance of high value items (e.g., space vehicles, reactor internals, or aircraft), medicine, and other tasks where a robot system failure poses a significant risk to life or property.

  3. Abusive behavior is barrier to high-reliability health care systems, culture of patient safety.

    PubMed

    Cassirer, C; Anderson, D; Hanson, S; Fraser, H

    2000-11-01

    Addressing abusive behavior in the medical workplace presents an important opportunity to deliver on the national commitment to improve patient safety. Fundamentally, the issue of patient safety and the issue of abusive behavior in the workplace are both about harm. Undiagnosed and untreated, abusive behavior is a barrier to creating high reliability service delivery systems that ensure patient safety. Health care managers and clinicians need to improve their awareness, knowledge, and understanding of the issue of workplace abuse. The available research suggests there is a high prevalence of workplace abuse in medicine. Both administrators at the blunt end and clinicians at the sharp end should consider learning new approaches to defining and treating the problem of workplace abuse. Eliminating abusive behavior has positive implications for preventing and controlling medical injury and improving organizational performance.

  4. Low-grade geothermal energy conversion by organic Rankine cycle turbine generator

    NASA Astrophysics Data System (ADS)

    Zarling, J. P.; Aspnes, J. D.

    Results of a demonstration project which helped determine the feasibility of converting low-grade thermal energy in 49 C water into electrical energy via an organic Rankine cycle 2500 watt (electrical) turbine-generator are presented. The geothermal source which supplied the water is located in a rural Alaskan village. The reasons an organic Rankine cycle turbine-generator was investigated as a possible source of electric power in rural Alaska are: (1) high cost of operating diesel-electric units and their poor long-term reliability when high-quality maintenance is unavailable and (2) the extremely high level of long-term reliability reportedly attained by commercially available organic Rankine cycle turbines. Data is provided on the thermal and electrical operating characteristics of an experimental organic Rankine cycle turbine-generator operating at a uniquely low vaporizer temperature.

  5. Short Scales for the Assessment of Personality Traits: Development and Validation of the Portuguese Ten-Item Personality Inventory (TIPI)

    PubMed Central

    Nunes, Andreia; Limpo, Teresa; Lima, César F.; Castro, São Luís

    2018-01-01

    The importance of quickly assessing personality traits in many studies prompted the development of brief scales such as the Ten-Item Personality Inventory (TIPI), a measure of five personality traits (extraversion, agreeableness, conscientiousness, emotional stability, and openness). In the current study, we present the Portuguese version of TIPI and examine its psychometric properties, based on a sample of 333 Portuguese adults aged 18 to 65 years. The results revealed reliability coefficients similar to the original version (α = 0.39–0.72), very good 4-week test–retest reliability (n = 81, rs > 0.71), expected factorial structure, high convergent validity with the Big-Five Inventory (rs > 0.60), and correlations with self-esteem, affect, and aggressiveness similar to those found with standard measures of personality traits. Overall, our findings suggest that the Portuguese TIPI is a reliable and valid alternative to longer measures: it offers a promising tool for research contexts in which the available time for personality assessment is highly limited. PMID:29674989

  6. Short Scales for the Assessment of Personality Traits: Development and Validation of the Portuguese Ten-Item Personality Inventory (TIPI).

    PubMed

    Nunes, Andreia; Limpo, Teresa; Lima, César F; Castro, São Luís

    2018-01-01

    The importance of quickly assessing personality traits in many studies prompted the development of brief scales such as the Ten-Item Personality Inventory (TIPI), a measure of five personality traits (extraversion, agreeableness, conscientiousness, emotional stability, and openness). In the current study, we present the Portuguese version of TIPI and examine its psychometric properties, based on a sample of 333 Portuguese adults aged 18 to 65 years. The results revealed reliability coefficients similar to the original version (α = 0.39-0.72), very good 4-week test-retest reliability ( n = 81, r s > 0.71), expected factorial structure, high convergent validity with the Big-Five Inventory ( r s > 0.60), and correlations with self-esteem, affect, and aggressiveness similar to those found with standard measures of personality traits. Overall, our findings suggest that the Portuguese TIPI is a reliable and valid alternative to longer measures: it offers a promising tool for research contexts in which the available time for personality assessment is highly limited.

  7. Maximally reliable Markov chains under energy constraints.

    PubMed

    Escola, Sean; Eisele, Michael; Miller, Kenneth; Paninski, Liam

    2009-07-01

    Signal-to-noise ratios in physical systems can be significantly degraded if the outputs of the systems are highly variable. Biological processes for which highly stereotyped signal generations are necessary features appear to have reduced their signal variabilities by employing multiple processing steps. To better understand why this multistep cascade structure might be desirable, we prove that the reliability of a signal generated by a multistate system with no memory (i.e., a Markov chain) is maximal if and only if the system topology is such that the process steps irreversibly through each state, with transition rates chosen such that an equal fraction of the total signal is generated in each state. Furthermore, our result indicates that by increasing the number of states, it is possible to arbitrarily increase the reliability of the system. In a physical system, however, an energy cost is associated with maintaining irreversible transitions, and this cost increases with the number of such transitions (i.e., the number of states). Thus, an infinite-length chain, which would be perfectly reliable, is infeasible. To model the effects of energy demands on the maximally reliable solution, we numerically optimize the topology under two distinct energy functions that penalize either irreversible transitions or incommunicability between states, respectively. In both cases, the solutions are essentially irreversible linear chains, but with upper bounds on the number of states set by the amount of available energy. We therefore conclude that a physical system for which signal reliability is important should employ a linear architecture, with the number of states (and thus the reliability) determined by the intrinsic energy constraints of the system.

  8. Expert system for UNIX system reliability and availability enhancement

    NASA Astrophysics Data System (ADS)

    Xu, Catherine Q.

    1993-02-01

    Highly reliable and available systems are critical to the airline industry. However, most off-the-shelf computer operating systems and hardware do not have built-in fault tolerant mechanisms, the UNIX workstation is one example. In this research effort, we have developed a rule-based Expert System (ES) to monitor, command, and control a UNIX workstation system with hot-standby redundancy. The ES on each workstation acts as an on-line system administrator to diagnose, report, correct, and prevent certain types of hardware and software failures. If a primary station is approaching failure, the ES coordinates the switch-over to a hot-standby secondary workstation. The goal is to discover and solve certain fatal problems early enough to prevent complete system failure from occurring and therefore to enhance system reliability and availability. Test results show that the ES can diagnose all targeted faulty scenarios and take desired actions in a consistent manner regardless of the sequence of the faults. The ES can perform designated system administration tasks about ten times faster than an experienced human operator. Compared with a single workstation system, our hot-standby redundancy system downtime is predicted to be reduced by more than 50 percent by using the ES to command and control the system.

  9. Expert System for UNIX System Reliability and Availability Enhancement

    NASA Technical Reports Server (NTRS)

    Xu, Catherine Q.

    1993-01-01

    Highly reliable and available systems are critical to the airline industry. However, most off-the-shelf computer operating systems and hardware do not have built-in fault tolerant mechanisms, the UNIX workstation is one example. In this research effort, we have developed a rule-based Expert System (ES) to monitor, command, and control a UNIX workstation system with hot-standby redundancy. The ES on each workstation acts as an on-line system administrator to diagnose, report, correct, and prevent certain types of hardware and software failures. If a primary station is approaching failure, the ES coordinates the switch-over to a hot-standby secondary workstation. The goal is to discover and solve certain fatal problems early enough to prevent complete system failure from occurring and therefore to enhance system reliability and availability. Test results show that the ES can diagnose all targeted faulty scenarios and take desired actions in a consistent manner regardless of the sequence of the faults. The ES can perform designated system administration tasks about ten times faster than an experienced human operator. Compared with a single workstation system, our hot-standby redundancy system downtime is predicted to be reduced by more than 50 percent by using the ES to command and control the system.

  10. Potential Use of Hydrogen as a Defense Logistics Fuel - Revision 1

    DTIC Science & Technology

    2004-11-01

    Macau Swaziland Costa Rica Macedonia Sweden Cyprus Malawi Switzerland Djibouti Maldives Togo Dominica Mali Tonga Dominican Republic Malta Turks and...Is high-pressure steam available for a turbine to power a compressor? * Can hydrogen be reliably produced on site? Geology of the area * Can it be

  11. GEODE An electrical energy supply with high availability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mertz, J.L.; Gerard, M.J.; Girard, J.

    1983-10-01

    Project GEODE describes an electrical energy supply characterized by its very high availability. It is to be used in the PTT (French Telephone Company) telephone exchanges and is targeted for an unavailability of better than 10/sup -6/. In order to achieve this performance Merlin Gerin has adopted: a double bus bar architecture, remote controlled electrical equipment, a motor-generator set specifically designed for this project, and computer assisted surveillance. The authors present the overall reliability calculations for this project along with that for energy sources. The E.d.F (French Utility Company) network and the Motor-Generators.

  12. Low-Frequency Fluctuations of the Resting Brain: High Magnitude Does Not Equal High Reliability

    PubMed Central

    Jia, Wenbin; Liao, Wei; Li, Xun; Huang, Huiyuan; Yuan, Jianhua; Zang, Yu-Feng; Zhang, Han

    2015-01-01

    The amplitude of low-frequency fluctuation (ALFF) measures low-frequency oscillations of the blood-oxygen-level-dependent signal, characterizing local spontaneous activity during the resting state. ALFF is a commonly used measure for resting-state functional magnetic resonance imaging (rs-fMRI) in numerous basic and clinical neuroscience studies. Using a test-retest rs-fMRI dataset consisting of 21 healthy subjects and three repetitive scans, we found that several key brain regions with high ALFF intensities (or magnitude) had poor reliability. Such regions included the posterior cingulate cortex, the medial prefrontal cortex in the default mode network, parts of the right and left thalami, and the primary visual and motor cortices. The above finding was robust with regard to different sample sizes (number of subjects), different scanning parameters (repetition time) and variations of test-retest intervals (i.e., intra-scan, intra-session, and inter-session reliability), as well as with different scanners. Moreover, the qualitative, map-wise results were validated further with a region-of-interest-based quantitative analysis using “canonical” coordinates as reported previously. Therefore, we suggest that the reliability assessments be incorporated in future ALFF studies, especially for the brain regions with a large ALFF magnitude as listed in our paper. Splitting single data into several segments and assessing within-scan “test-retest” reliability is an acceptable alternative if no “real” test-retest datasets are available. Such evaluations might become more necessary if the data are collected with clinical scanners whose performance is not as good as those that are used for scientific research purposes and are better maintained because the lower signal-to-noise ratio may further dampen ALFF reliability. PMID:26053265

  13. Retest reliability of individual alpha ERD topography assessed by human electroencephalography.

    PubMed

    Vázquez-Marrufo, Manuel; Galvao-Carmona, Alejandro; Benítez Lugo, María Luisa; Ruíz-Peña, Juan Luis; Borges Guerra, Mónica; Izquierdo Ayuso, Guillermo

    2017-01-01

    Despite the immense literature related to diverse human electroencephalographic (EEG) parameters, very few studies have focused on the reliability of these measures. Some of the most studied components (i.e., P3 or MMN) have received more attention regarding the stability of their main parameters, such as latency, amplitude or topography. However, spectral modulations have not been as extensively evaluated considering that different analysis methods are available. The main aim of the present study is to assess the reliability of the latency, amplitude and topography of event-related desynchronization (ERD) for the alpha band (10-14 Hz) observed in a cognitive task (visual oddball). Topography reliability was analysed at different levels (for the group, within-subjects individually and between-subjects individually). The latency for alpha ERD showed stable behaviour between two sessions, and the amplitude exhibited an increment (more negative) in the second session. Alpha ERD topography exhibited a high correlation score between sessions at the group level (r = 0.903, p<0.001). The mean value for within-subject correlations was 0.750 (with a range from 0.391 to 0.954). Regarding between-subject topography comparisons, some subjects showed a highly specific topography, whereas other subjects showed topographies that were more similar to those of other subjects. ERD was mainly stable between the two sessions with the exception of amplitude, which exhibited an increment in the second session. Topography exhibits excellent reliability at the group level; however, it exhibits highly heterogeneous behaviour at the individual level. Considering that the P3 was previously evaluated for this group of subjects, a direct comparison of the correlation scores was possible, and it showed that the ERD component is less reliable in individual topography than in the ERP component (P3).

  14. Retest reliability of individual alpha ERD topography assessed by human electroencephalography

    PubMed Central

    Vázquez-Marrufo, Manuel; Benítez Lugo, María Luisa; Ruíz-Peña, Juan Luis; Borges Guerra, Mónica; Izquierdo Ayuso, Guillermo

    2017-01-01

    Background Despite the immense literature related to diverse human electroencephalographic (EEG) parameters, very few studies have focused on the reliability of these measures. Some of the most studied components (i.e., P3 or MMN) have received more attention regarding the stability of their main parameters, such as latency, amplitude or topography. However, spectral modulations have not been as extensively evaluated considering that different analysis methods are available. The main aim of the present study is to assess the reliability of the latency, amplitude and topography of event-related desynchronization (ERD) for the alpha band (10–14 Hz) observed in a cognitive task (visual oddball). Topography reliability was analysed at different levels (for the group, within-subjects individually and between-subjects individually). Results The latency for alpha ERD showed stable behaviour between two sessions, and the amplitude exhibited an increment (more negative) in the second session. Alpha ERD topography exhibited a high correlation score between sessions at the group level (r = 0.903, p<0.001). The mean value for within-subject correlations was 0.750 (with a range from 0.391 to 0.954). Regarding between-subject topography comparisons, some subjects showed a highly specific topography, whereas other subjects showed topographies that were more similar to those of other subjects. Conclusion ERD was mainly stable between the two sessions with the exception of amplitude, which exhibited an increment in the second session. Topography exhibits excellent reliability at the group level; however, it exhibits highly heterogeneous behaviour at the individual level. Considering that the P3 was previously evaluated for this group of subjects, a direct comparison of the correlation scores was possible, and it showed that the ERD component is less reliable in individual topography than in the ERP component (P3). PMID:29088307

  15. System reliability approaches for advanced propulsion system structures

    NASA Technical Reports Server (NTRS)

    Cruse, T. A.; Mahadevan, S.

    1991-01-01

    This paper identifies significant issues that pertain to the estimation and use of system reliability in the design of advanced propulsion system structures. Linkages between the reliabilities of individual components and their effect on system design issues such as performance, cost, availability, and certification are examined. The need for system reliability computation to address the continuum nature of propulsion system structures and synergistic progressive damage modes has been highlighted. Available system reliability models are observed to apply only to discrete systems. Therefore a sequential structural reanalysis procedure is formulated to rigorously compute the conditional dependencies between various failure modes. The method is developed in a manner that supports both top-down and bottom-up analyses in system reliability.

  16. Optimizing preventive maintenance policy: A data-driven application for a light rail braking system.

    PubMed

    Corman, Francesco; Kraijema, Sander; Godjevac, Milinko; Lodewijks, Gabriel

    2017-10-01

    This article presents a case study determining the optimal preventive maintenance policy for a light rail rolling stock system in terms of reliability, availability, and maintenance costs. The maintenance policy defines one of the three predefined preventive maintenance actions at fixed time-based intervals for each of the subsystems of the braking system. Based on work, maintenance, and failure data, we model the reliability degradation of the system and its subsystems under the current maintenance policy by a Weibull distribution. We then analytically determine the relation between reliability, availability, and maintenance costs. We validate the model against recorded reliability and availability and get further insights by a dedicated sensitivity analysis. The model is then used in a sequential optimization framework determining preventive maintenance intervals to improve on the key performance indicators. We show the potential of data-driven modelling to determine optimal maintenance policy: same system availability and reliability can be achieved with 30% maintenance cost reduction, by prolonging the intervals and re-grouping maintenance actions.

  17. Optimizing preventive maintenance policy: A data-driven application for a light rail braking system

    PubMed Central

    Corman, Francesco; Kraijema, Sander; Godjevac, Milinko; Lodewijks, Gabriel

    2017-01-01

    This article presents a case study determining the optimal preventive maintenance policy for a light rail rolling stock system in terms of reliability, availability, and maintenance costs. The maintenance policy defines one of the three predefined preventive maintenance actions at fixed time-based intervals for each of the subsystems of the braking system. Based on work, maintenance, and failure data, we model the reliability degradation of the system and its subsystems under the current maintenance policy by a Weibull distribution. We then analytically determine the relation between reliability, availability, and maintenance costs. We validate the model against recorded reliability and availability and get further insights by a dedicated sensitivity analysis. The model is then used in a sequential optimization framework determining preventive maintenance intervals to improve on the key performance indicators. We show the potential of data-driven modelling to determine optimal maintenance policy: same system availability and reliability can be achieved with 30% maintenance cost reduction, by prolonging the intervals and re-grouping maintenance actions. PMID:29278245

  18. Availability and quality of cause-of-death data for estimating the global burden of injuries

    PubMed Central

    Harrison, James E; Shahraz, Saeid; Fingerhut, Lois A

    2010-01-01

    Abstract Objective To assess the availability and quality of global death registration data used for estimating injury mortality. Methods The completeness and coverage of recent national death registration data from the World Health Organization mortality database were assessed. The quality of data on a specific cause of injury death was judged high if fewer than 20% of deaths were attributed to any of several partially specified causes of injury, such as “unspecified unintentional injury”. Findings Recent death registration data were available for 83 countries, comprising 28% of the global population. They included most high-income countries, most countries in Latin America and several in central Asia and the Caribbean. Categories commonly used for partially specified external causes of injury resulting in death included “undetermined intent,” “unspecified mechanism of unintentional injury,” “unspecified road injury” and “unspecified mechanism of homicide”. Only 20 countries had high-quality data. Nevertheless, because the partially specified categories do contain some information about injury mechanisms, reliable estimates of deaths due to specific external causes of injury, such as road injury, suicide and homicide, could be derived for many more countries. Conclusion Only 20 countries had high-quality death registration data that could be used for estimating injury mortality because injury deaths were frequently classified using imprecise partially specified categories. Analytical methods that can derive national estimates of injury mortality from alternative data sources are needed for countries without reliable death registration systems. PMID:21076564

  19. Frequency doubled high-power disk lasers in pulsed and continuous-wave operation

    NASA Astrophysics Data System (ADS)

    Weiler, Sascha; Hangst, Alexander; Stolzenburg, Christian; Zawischa, Ivo; Sutter, Dirk; Killi, Alexander; Kalfhues, Steffen; Kriegshaeuser, Uwe; Holzer, Marco; Havrilla, David

    2012-03-01

    The disk laser with multi-kW output power in infrared cw operation is widely used in today's manufacturing, primarily in the automotive industry. The disk technology combines high power (average and/or peak power), excellent beam quality, high efficiency and high reliability with low investment and operating costs. Additionally, the disk laser is ideally suited for frequency conversion due to its polarized output with negligible depolarization losses. Laser light in the green spectral range (~515 nm) can be created with a nonlinear crystal. Pulsed disk lasers with green output of well above 50 W (extracavity doubling) in the ps regime and several hundreds of Watts in the ns regime with intracavity doubling are already commercially available whereas intracavity doubled disk lasers in continuous wave operation with greater than 250 W output are in test phase. In both operating modes (pulsed and cw) the frequency doubled disk laser offers advantages in existing and new applications. Copper welding for example is said to show much higher process reliability with green laser light due to its higher absorption in comparison to the infrared. This improvement has the potential to be very beneficial for the automotive industry's move to electrical vehicles which requires reliable high-volume welding of copper as a major task for electro motors, batteries, etc.

  20. A Mixed-methods Study to Assess Interrater Reliability and Nurse Perception of the Braden Scale in a Tertiary Acute Care Setting.

    PubMed

    Ho, Chester H; Cheung, Amanda; Southern, Danielle; Ocampo, Wrechelle; Kaufman, Jaime; Hogan, David B; Baylis, Barry; Conly, John M; Stelfox, Henry T; Ghali, William A

    2016-12-01

    Research regarding the reliability of the Braden Scale and nurses' perspectives on the instrument for predicting pressure ulcer (PU) risk in acute care settings is limited. A mixed-methods study was conducted in a tertiary acute care facility to examine interrater reliability (IRR) of the Braden Scale and its subscales, and a qualitative survey using semi-structured interviews was conducted among nurses caring for patients in acute care units to gain nurse perspective regarding scale usability. Data were extracted from a previous retrospective, randomized, controlled trial involving adult patients with compromised mobility receiving care in a tertiary acute care hospital in Canada. One-way, intraclass correlation coefficients (ICCs) were calculated on item and total scores, and kappa statistics were used to determine reliability of categorizing patients on their risk. Interview results were categorized by common themes. Reliability was assessed on 64 patients, where nurses and research staff independently assessed enrolled participants at baseline and after 72 hours using the Braden Scale as it appeared on an electronic medical record. IRR for the total score was high (ICC = 0.807). The friction and shear item had the lowest reliability (ICC = 0.266). Reliability of categorizing patients' level of risk had moderate agreement (κ = 0.408). Three (3) major and 12 subthemes emerged from the 14 nurse interviews; nurses were aware of the scale's purpose but were uncertain of its effectiveness, some items were difficult to rate, and questions were raised as to whether using the scale enhanced patient care. Aspects identified by nurses to enhance usability included: 1) changes to the electronic version (incorporating the scale into daily assessment documents with readily available item descriptions), 2) additional training, and 3) easily available resource material to improve reliability and usability of scale. These findings need to be considered when using the Braden Scale in clinical practice. Further study of the value of the total Braden Scale and its subscales is warranted.

  1. Loss of Load Probability Calculation for West Java Power System with Nuclear Power Plant Scenario

    NASA Astrophysics Data System (ADS)

    Azizah, I. D.; Abdullah, A. G.; Purnama, W.; Nandiyanto, A. B. D.; Shafii, M. A.

    2017-03-01

    Loss of Load Probability (LOLP) index showing the quality and performance of an electrical system. LOLP value is affected by load growth, the load duration curve, forced outage rate of the plant, number and capacity of generating units. This reliability index calculation begins with load forecasting to 2018 using multiple regression method. Scenario 1 with compositions of conventional plants produce the largest LOLP in 2017 amounted to 71.609 days / year. While the best reliability index generated in scenario 2 with the NPP amounted to 6.941 days / year in 2015. Improved reliability of systems using nuclear power more efficiently when compared to conventional plants because it also has advantages such as emission-free, inexpensive fuel costs, as well as high level of plant availability.

  2. Systems Issues In Terrestrial Fiber Optic Link Reliability

    NASA Astrophysics Data System (ADS)

    Spencer, James L.; Lewin, Barry R.; Lee, T. Frank S.

    1990-01-01

    This paper reviews fiber optic system reliability issues from three different viewpoints - availability, operating environment, and evolving technologies. Present availability objectives for interoffice links and for the distribution loop must be re-examined for applications such as the Synchronous Optical Network (SONET), Fiber-to-the-Home (FTTH), and analog services. The hostile operating environments of emerging applications (such as FTTH) must be carefully considered in system design as well as reliability assessments. Finally, evolving technologies might require the development of new reliability testing strategies.

  3. Space Station Freedom power - A reliability, availability, and maintainability assessment of the proposed Space Station Freedom electric power system

    NASA Technical Reports Server (NTRS)

    Turnquist, S. R.; Twombly, M.; Hoffman, D.

    1989-01-01

    A preliminary reliability, availability, and maintainability (RAM) analysis of the proposed Space Station Freedom electric power system (EPS) was performed using the unit reliability, availability, and maintainability (UNIRAM) analysis methodology. Orbital replacement units (ORUs) having the most significant impact on EPS availability measures were identified. Also, the sensitivity of the EPS to variations in ORU RAM data was evaluated for each ORU. Estimates were made of average EPS power output levels and availability of power to the core area of the space station. The results of assessments of the availability of EPS power and power to load distribution points in the space stations are given. Some highlights of continuing studies being performed to understand EPS availability considerations are presented.

  4. Space flight risk data collection and analysis project: Risk and reliability database

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The focus of the NASA 'Space Flight Risk Data Collection and Analysis' project was to acquire and evaluate space flight data with the express purpose of establishing a database containing measurements of specific risk assessment - reliability - availability - maintainability - supportability (RRAMS) parameters. The developed comprehensive RRAMS database will support the performance of future NASA and aerospace industry risk and reliability studies. One of the primary goals has been to acquire unprocessed information relating to the reliability and availability of launch vehicles and the subsystems and components thereof from the 45th Space Wing (formerly Eastern Space and Missile Command -ESMC) at Patrick Air Force Base. After evaluating and analyzing this information, it was encoded in terms of parameters pertinent to ascertaining reliability and availability statistics, and then assembled into an appropriate database structure.

  5. Reliability analysis of component of affination centrifugal 1 machine by using reliability engineering

    NASA Astrophysics Data System (ADS)

    Sembiring, N.; Ginting, E.; Darnello, T.

    2017-12-01

    Problems that appear in a company that produces refined sugar, the production floor has not reached the level of critical machine availability because it often suffered damage (breakdown). This results in a sudden loss of production time and production opportunities. This problem can be solved by Reliability Engineering method where the statistical approach to historical damage data is performed to see the pattern of the distribution. The method can provide a value of reliability, rate of damage, and availability level, of an machine during the maintenance time interval schedule. The result of distribution test to time inter-damage data (MTTF) flexible hose component is lognormal distribution while component of teflon cone lifthing is weibull distribution. While from distribution test to mean time of improvement (MTTR) flexible hose component is exponential distribution while component of teflon cone lifthing is weibull distribution. The actual results of the flexible hose component on the replacement schedule per 720 hours obtained reliability of 0.2451 and availability 0.9960. While on the critical components of teflon cone lifthing actual on the replacement schedule per 1944 hours obtained reliability of 0.4083 and availability 0.9927.

  6. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips.

    PubMed

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-09-01

    Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  7. Validation of the Bulgarian version of Scales for Outcomes in Parkinson's Disease - Autonomic (SCOPA-AUT-BG).

    PubMed

    Mantarova, Stefka G; Velcheva, Irena V; Georgieva, Spaska O; Stambolieva, Katerina I

    2013-01-01

    The last twenty years have witnessed a surge of interest in the autonomic symptoms in Parkinson's disease (PD) and the possibilities to diagnose and treat them. The specialized questionnaire assessing the autonomic symptoms in Parkinson's disease (SCOPA-AUT) has been validated and available in English, Dutch and Spanish. In this study we aim at evaluating the validity, reliability and applicability of the Bulgarian version of SCOPA-AUT (SCOPA-AUT-BG). The study included 55 patients with idiopathic PD (mean age 64.4 +/- 8.9 yrs), and 40 healthy controls (mean age 58.5 +/- 9.4 yrs). Clinical severity and disease stage were assessed by United Parkinson's disease rating scale (UPRDS) and Hoen and Yahr (H&Y). Thirty-two of the PD patients completed SCOPA-AUT-BG again after a 7-day interval. Questionnaire reliability was analyzed by determining the internal consistency, homogeneity, discriminatory and construct validity and test-retest reliability. Analyses showed good internal consistency of the summary evaluation of SCOPA-AUT-BG (coefficient alpha of Cronbach = 0.79), which indicates the high reliability of the questionnaire. The lowest Cronbach's alpha coefficient (0.53) was found for the subscale "cardiovascular functions". A dominant role belongs to the subscales for gastrointestinal and urinary functions (Cronbach's Alpha > 0.7), where a significantly high correlation of PD with the UPDRS scale was observed. We found high test-retest reliability based on the responses associated with dysfunction of the gastrointestinal, urinary, thermoregulatory and pupillary autonomic systems. The correlation of the results of SCOPA-AUT-BG with UPDRS is higher than that with H&Y, and the construct validity is high except for the cardiovascular and pupillomotor functions subscales. The results of this study show that SCOPA-AUT-BG is a valid and reliable specialized questionnaire to evaluate autonomic function in patients with Parkinson's disease. Using it allows for more detailed clinical evaluation of these patients and justifies the need to refer them to specialized examination of autonomic functions.

  8. The alcohol use disorder and associated disabilities interview schedule-IV (AUDADIS-IV): reliability of new psychiatric diagnostic modules and risk factors in a general population sample.

    PubMed

    Ruan, W June; Goldstein, Risë B; Chou, S Patricia; Smith, Sharon M; Saha, Tulshi D; Pickering, Roger P; Dawson, Deborah A; Huang, Boji; Stinson, Frederick S; Grant, Bridget F

    2008-01-01

    This study presents test-retest reliability statistics and information on internal consistency for new diagnostic modules and risk factors for alcohol, drug, and psychiatric disorders from the Alcohol Use Disorder and Associated Disabilities Interview Schedule-IV (AUDADIS-IV). Test-retest statistics were derived from a random sample of 1899 adults selected from 34,653 respondents who participated in the 2004-2005 Wave 2 National Epidemiologic Survey on Alcohol and Related Conditions (NESARC). Internal consistency of continuous scales was assessed using the entire Wave 2 NESARC. Both test and retest interviews were conducted face-to-face. Test-retest and internal consistency results for diagnoses and symptom scales associated with posttraumatic stress disorder, attention-deficit/hyperactivity disorder, and borderline, narcissistic, and schizotypal personality disorders were predominantly good (kappa>0.63; ICC>0.69; alpha>0.75) and reliability for risk factor measures fell within the good to excellent range (intraclass correlations=0.50-0.94; alpha=0.64-0.90). The high degree of reliability found in this study suggests that new AUDADIS-IV diagnostic measures can be useful tools in research settings. The availability of highly reliable measures of risk factors for alcohol, drug, and psychiatric disorders will contribute to the validity of conclusions drawn from future research in the domains of substance use disorder and psychiatric epidemiology.

  9. Concordance and Reliability of Photogrammetric Protocols for Measuring the Cervical Lordosis Angle: A Systematic Review of the Literature.

    PubMed

    de Albuquerque, Priscila Maria Nascimento Martins; de Alencar, Geisa Guimarães; de Oliveira, Daniela Araújo; de Siqueira, Gisela Rocha

    2018-01-01

    The aim of this study was to examine and interpret the concordance, accuracy, and reliability of photogrammetric protocols available in the literature for evaluating cervical lordosis in an adult population aged 18 to 59 years. A systematic search of 6 electronic databases (MEDLINE via PubMed, LILACS, CINAHL, Scopus, ScienceDirect, and Web of Science) located studies that assessed the reliability and/or concordance and/or accuracy of photogrammetric protocols for evaluating cervical lordosis, compared with radiography. Articles published through April 2016 were selected. Two independent reviewers used a critical appraisal tool (QUADAS and QAREL) to assess the quality of the selected studies. Two studies were included in the review and had high levels of reliability (intraclass correlation coefficient: 0.974-0.98). Only 1 study assessed the concordance between the methods, which was calculated using Pearson's correlation coefficient. To date, the accuracy of photogrammetry has not been investigated thoroughly. We encountered no study in the literature that investigated the accuracy of photogrammetry in diagnosing hyperlordosis of cervical spine. However, both current studies report high levels of intra- and interrater reliability. To increase the level of evidence of photogrammetry in the evaluation of cervical lordosis, it is necessary to conduct further studies using a larger sample to increase the external validity of the findings. Copyright © 2018. Published by Elsevier Inc.

  10. Quantitative Determination of Bioactive Constituents in Noni Juice by High-performance Liquid Chromatography with Electrospray Ionization Triple Quadrupole Mass Spectrometry.

    PubMed

    Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping

    2018-01-01

    Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C 18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values ( R 2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was <0.91% and the repeatability between 1.36% and 3.31%. The accuracy varied from 96.40% to 103.02% and the relative standard deviations of stability were <3.91%. Samples from the same origin showed similar content while different origins showed significant different result. The developed methods would provide a reliable basis and be useful in the establishment of a rational quality control standard of Noni juice. Separation, identification, and simultaneous quantitative analysis method of seven bioactive constituents in Noni juice is originally developed by high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT: Retention time.

  11. Quantitative Determination of Bioactive Constituents in Noni Juice by High-performance Liquid Chromatography with Electrospray Ionization Triple Quadrupole Mass Spectrometry

    PubMed Central

    Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping

    2018-01-01

    Background: Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. Objective: To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. Materials and Methods: The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Results: Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values (R2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was <0.91% and the repeatability between 1.36% and 3.31%. The accuracy varied from 96.40% to 103.02% and the relative standard deviations of stability were <3.91%. Samples from the same origin showed similar content while different origins showed significant different result. Conclusions: The developed methods would provide a reliable basis and be useful in the establishment of a rational quality control standard of Noni juice. SUMMARY Separation, identification, and simultaneous quantitative analysis method of seven bioactive constituents in Noni juice is originally developed by high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT: Retention time. PMID:29576704

  12. Challenges for Wireless Mesh Networks to provide reliable carrier-grade services

    NASA Astrophysics Data System (ADS)

    von Hugo, D.; Bayer, N.

    2011-08-01

    Provision of mobile and wireless services today within a competitive environment and driven by a huge amount of steadily emerging new services and applications is both challenge and chance for radio network operators. Deployment and operation of an infrastructure for mobile and wireless broadband connectivity generally requires planning effort and large investments. A promising approach to reduce expenses for radio access networking is offered by Wireless Mesh Networks (WMNs). Here traditional dedicated backhaul connections to each access point are replaced by wireless multi-hop links between neighbouring access nodes and few gateways to the backbone employing standard radio technology. Such a solution provides at the same time high flexibility in both deployment and the amount of offered capacity and shall reduce overall expenses. On the other hand currently available mesh solutions do not provide carrier grade service quality and reliability and often fail to cope with high traffic load. EU project CARMEN (CARrier grade MEsh Networks) was initiated to incorporate different heterogeneous technologies and new protocols to allow for reliable transmission over "best effort" radio channels, to support a reliable mobility and network management, self-configuration and dynamic resource usage, and thus to offer a permanent or temporary broadband access at high cost efficiency. The contribution provides an overview on preliminary project results with focus on main technical challenges from a research and implementation point of view. Especially impact of mesh topology on the overall system performance in terms of throughput and connection reliability and aspects of a dedicated hybrid mobility management solution will be discussed.

  13. A sensitive and reliable test instrument to assess swimming in rats with spinal cord injury.

    PubMed

    Xu, Ning; Åkesson, Elisabet; Holmberg, Lena; Sundström, Erik

    2015-09-15

    For clinical translation of experimental spinal cord injury (SCI) research, evaluation of animal SCI models should include several sensorimotor functions. Validated and reliable assessment tools should be applicable to a wide range of injury severity. The BBB scale is the most widely used test instrument, but similar to most others it is used to assess open field ambulation. We have developed an assessment tool for swimming in rats with SCI, with high discriminative power and sensitivity to functional recovery after mild and severe injuries, without need for advanced test equipment. We studied various parameters of swimming in four groups of rats with thoracic SCI of different severity and a control group, for 8 weeks after surgery. Six parameters were combined in a multiple item scale, the Karolinska Institutet Swim Assessment Tool (KSAT). KSAT scores for all SCI groups showed consistent functional improvement after injury, and significant differences between the five experimental groups. The internal consistency, the inter-rater and the test-retest reliability were very high. The KSAT score was highly correlated to the cross-section area of white matter spared at the injury epicenter. Importantly, even after 8 weeks of recovery the KSAT score reliably discriminated normal animals from those inflicted by the mildest injury, and also displayed the recovery of the most severely injured rats. We conclude that this swim scale is an efficient and reliable tool to assess motor activity during swimming, and an important addition to the methods available for evaluating rat models of SCI. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. 2015 NREL Photovoltaic Reliability Workshops | Photovoltaic Research | NREL

    Science.gov Websites

    5 NREL Photovoltaic Reliability Workshops 2015 NREL Photovoltaic Reliability Workshops The 2015 NREL Photovoltaic Reliability Workshop was held February 24-27, 2015, in Golden, Colorado. This event be available for download as soon as possible. The Photovoltaic Module Reliability Workshop is

  15. Identification of Social Anxiety in Schools: The Utility of a Two-Step Screening Process

    ERIC Educational Resources Information Center

    Sweeney, Corinne; Masia Warner, Carrie; Brice, Chad; Stewart, Catherine; Ryan, Julie; Loeb, Katharine L.; McGrath, Robert E.

    2015-01-01

    Social anxiety disorder (SAD) is highly prevalent yet largely undetected and untreated in adolescents despite the availability of effective treatments. Implementing interventions in schools enhances recognition and access to treatment for SAD. However, without reliable means to accurately identify youth in need of services, school-based…

  16. Laser Crystal

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Lightning Optical Corporation, under an SBIR (Small Business Innovative Research) agreement with Langley Research Center, manufactures oxide and fluoride laser gain crystals, as well as various nonlinear materials. The ultimate result of this research program is the commercial availability in the marketplace of a reliable source of high-quality, damage resistant laser material, primarily for diode-pumping applications.

  17. Development and Validation of Mobile Learning Acceptance Measure

    ERIC Educational Resources Information Center

    Sharma, Sujeet Kumar; Sarrab, Mohamed; Al-Shihi, Hafedh

    2017-01-01

    The growth of Smartphone usage, increased acceptance of electronic learning (E-learning), the availability of high reliability mobile networks and need for flexibility in learning have resulted in the growth of mobile learning (M-learning). This has led to a tremendous interest in the acceptance behaviors related to M-learning users among the…

  18. High-Temperature Storage Testing of ACF Attached Sensor Structures

    PubMed Central

    Lahokallio, Sanna; Hoikkanen, Maija; Vuorinen, Jyrki; Frisk, Laura

    2015-01-01

    Several electronic applications must withstand elevated temperatures during their lifetime. Materials and packages for use in high temperatures have been designed, but they are often very expensive, have limited compatibility with materials, structures, and processing techniques, and are less readily available than traditional materials. Thus, there is an increasing interest in using low-cost polymer materials in high temperature applications. This paper studies the performance and reliability of sensor structures attached with anisotropically conductive adhesive film (ACF) on two different organic printed circuit board (PCB) materials: FR-4 and Rogers. The test samples were aged at 200 °C and 240 °C and monitored electrically during the test. Material characterization techniques were also used to analyze the behavior of the materials. Rogers PCB was observed to be more stable at high temperatures in spite of degradation observed, especially during the first 120 h of aging. The electrical reliability was very good with Rogers. At 200 °C, the failures occurred after 2000 h of testing, and even at 240 °C the interconnections were functional for 400 h. The study indicates that, even though these ACFs were not designed for use in high temperatures, with stable PCB material they are promising interconnection materials at elevated temperatures, especially at 200 °C. However, the fragility of the structure due to material degradation may cause reliability problems in long-term high temperature exposure. PMID:28793735

  19. HiRel: Hybrid Automated Reliability Predictor (HARP) integrated reliability tool system, (version 7.0). Volume 2: HARP tutorial

    NASA Technical Reports Server (NTRS)

    Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Bavuso, Salvatore J.

    1994-01-01

    The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. The Hybrid Automated Reliability Predictor (HARP) tutorial provides insight into HARP modeling techniques and the interactive textual prompting input language via a step-by-step explanation and demonstration of HARP's fault occurrence/repair model and the fault/error handling models. Example applications are worked in their entirety and the HARP tabular output data are presented for each. Simple models are presented at first with each succeeding example demonstrating greater modeling power and complexity. This document is not intended to present the theoretical and mathematical basis for HARP.

  20. Psychometric evaluation of commonly used game-specific skills tests in rugby: A systematic review

    PubMed Central

    Oorschot, Sander; Chiwaridzo, Matthew; CM Smits-Engelsman, Bouwien

    2017-01-01

    Objectives To (1) give an overview of commonly used game-specific skills tests in rugby and (2) evaluate available psychometric information of these tests. Methods The databases PubMed, MEDLINE CINAHL and Africa Wide information were systematically searched for articles published between January 1995 and March 2017. First, commonly used game-specific skills tests were identified. Second, the available psychometrics of these tests were evaluated and the methodological quality of the studies assessed using the Consensus-based Standards for the selection of health Measurement Instruments checklist. Studies included in the first step had to report detailed information on the construct and testing procedure of at least one game-specific skill, and studies included in the second step had additionally to report at least one psychometric property evaluating reliability, validity or responsiveness. Results 287 articles were identified in the first step, of which 30 articles met the inclusion criteria and 64 articles were identified in the second step of which 10 articles were included. Reactive agility, tackling and simulated rugby games were the most commonly used tests. All 10 studies reporting psychometrics reported reliability outcomes, revealing mainly strong evidence. However, all studies scored poor or fair on methodological quality. Four studies reported validity outcomes in which mainly moderate evidence was indicated, but all articles had fair methodological quality. Conclusion Game-specific skills tests indicated mainly high reliability and validity evidence, but the studies lacked methodological quality. Reactive agility seems to be a promising domain, but the specific tests need further development. Future high methodological quality studies are required in order to develop valid and reliable test batteries for rugby talent identification. Trial registration number PROSPERO CRD42015029747. PMID:29259812

  1. RICOR K527 highly reliable linear cooler: applications and model overview

    NASA Astrophysics Data System (ADS)

    Riabzev, Sergey; Nachman, Ilan; Levin, Eli; Perach, Adam; Vainshtein, Igor; Gover, Dan

    2017-05-01

    The K527 linear cooler was developed in order to meet the requirements of reliability, cooling power needs and versatility for a wide range of applications such as hand held, 24/7 and MWS. During the recent years the cooler was incorporated in variety of systems. Some of these systems can be sensitive to vibrations which are induced from the cooler. In order to reduce those vibrations significantly, a Tuned Dynamic Absorber (TDA) was added to the cooler. Other systems, such as the MWS type, are not sensitive to vibrations, but require a robust cooler in order to meet the high demand for environmental vibration and temperature. Therefore various mounting interfaces are designed to meet system requirements. The latest K527 version was designed to be integrated with the K508 cold finger, in order to give it versatility to standard detectors that are already designed and available for the K508 cooler type. The reliability of the cooler is of a high priority. In order to meet the 30,000 working hours target, special design features were implemented. Eight K527 coolers have passed the 19,360 working hours without degradations, and are still running according to our expectations.

  2. Reliability of CGA/LGA/HDI Package Board/Assembly (Revision A)

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2013-01-01

    This follow-up report presents reliability test results conducted by thermal cycling of five CGA assemblies evaluated under two extreme cycle profiles, representative of use for high-reliability applications. The thermal cycles ranged from a low temperature of 55 C to maximum temperatures of either 100 C or 125 C with slow ramp-up rate (3 C/min) and dwell times of about 15 minutes at the two extremes. Optical photomicrographs that illustrate key inspection findings of up to 200 thermal cycles are presented. Other information presented include an evaluation of the integrity of capacitors on CGA substrate after thermal cycling as well as process evaluation for direct assembly of an LGA onto PCB. The qualification guidelines, which are based on the test results for CGA/LGA/HDI packages and board assemblies, will facilitate NASA projects' use of very dense and newly available FPGA area array packages with known reliably and mitigation risks, allowing greater processing power in a smaller board footprint and lower system weight.

  3. Cross-organism learning method to discover new gene functionalities.

    PubMed

    Domeniconi, Giacomo; Masseroli, Marco; Moro, Gianluca; Pinoli, Pietro

    2016-04-01

    Knowledge of gene and protein functions is paramount for the understanding of physiological and pathological biological processes, as well as in the development of new drugs and therapies. Analyses for biomedical knowledge discovery greatly benefit from the availability of gene and protein functional feature descriptions expressed through controlled terminologies and ontologies, i.e., of gene and protein biomedical controlled annotations. In the last years, several databases of such annotations have become available; yet, these valuable annotations are incomplete, include errors and only some of them represent highly reliable human curated information. Computational techniques able to reliably predict new gene or protein annotations with an associated likelihood value are thus paramount. Here, we propose a novel cross-organisms learning approach to reliably predict new functionalities for the genes of an organism based on the known controlled annotations of the genes of another, evolutionarily related and better studied, organism. We leverage a new representation of the annotation discovery problem and a random perturbation of the available controlled annotations to allow the application of supervised algorithms to predict with good accuracy unknown gene annotations. Taking advantage of the numerous gene annotations available for a well-studied organism, our cross-organisms learning method creates and trains better prediction models, which can then be applied to predict new gene annotations of a target organism. We tested and compared our method with the equivalent single organism approach on different gene annotation datasets of five evolutionarily related organisms (Homo sapiens, Mus musculus, Bos taurus, Gallus gallus and Dictyostelium discoideum). Results show both the usefulness of the perturbation method of available annotations for better prediction model training and a great improvement of the cross-organism models with respect to the single-organism ones, without influence of the evolutionary distance between the considered organisms. The generated ranked lists of reliably predicted annotations, which describe novel gene functionalities and have an associated likelihood value, are very valuable both to complement available annotations, for better coverage in biomedical knowledge discovery analyses, and to quicken the annotation curation process, by focusing it on the prioritized novel annotations predicted. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Development of tungsten armor and bonding to copper for plasma-interactive components

    NASA Astrophysics Data System (ADS)

    Smid, I.; Akiba, M.; Vieider, G.; Plöchl, L.

    1998-10-01

    For the highest sputtering threshold of all possible candidates, tungsten will be the most likely armor material in highly loaded plasma-interactive components of commercially relevant fusion reactors. The development of new materials, as well as joining and coating techniques are needed to find the best balance in plasma compatibility, lifetime, reliability, neutron irradiation resistance, and safety. Further important issues for selection are availability, costs of machining and production, etc. Tungsten doped with lanthanum oxide is a commercially available W grade for electrodes, designed for low electron work function, higher recrystallization temperature, reduced secondary grain growth, and machinability at relatively low costs. W-Re and related tungsten base alloys are preferred for application at high temperatures, when high strength, high thermal shock and recrystallization resistance are required. Due to the high costs and limited global availability of Re, however, the amount of such alloys in a commercial reactor should be kept low. Newly measured material properties up to high temperatures are presented for lanthanated and W-Re alloys, and the impact on fusion application is discussed. Recently developed coatings of chemical vapor deposited tungsten (CVD-W) on copper substrates have proven to be resistant to repeated thermal and shock loading. Layers of more than 5 mm, as required for the International Thermonuclear Experimental Reactor (ITER), became available. Vacuum plasma sprayed tungsten (VPS-W) in particular is attractive for its lower costs, and the potential of in situ repair. However, the advantage of sacrificial plasma-interactive tungsten coatings in long-term fusion devices has yet to be demonstrated. A durable and reliable joining of bulk tungsten to copper is needed to achieve an acceptable component lifetime in a fusion environment. The material properties of the copper alloys proposed for ITER, and their impact on the quality of bonding to tungsten is discussed. Future materials R&D should concern issues such as plasma compatibility, and above all neutron irradiation damage of promising tungsten-copper joints.

  5. Evaluation of tools used to measure calcium and/or dairy consumption in adults.

    PubMed

    Magarey, Anthea; Baulderstone, Lauren; Yaxley, Alison; Markow, Kylie; Miller, Michelle

    2015-05-01

    To identify and critique tools for the assessment of Ca and/or dairy intake in adults, in order to ascertain the most accurate and reliable tools available. A systematic review of the literature was conducted using defined inclusion and exclusion criteria. Articles reporting on originally developed tools or testing the reliability or validity of existing tools that measure Ca and/or dairy intake in adults were included. Author-defined criteria for reporting reliability and validity properties were applied. Studies conducted in Western countries. Adults. Thirty papers, utilising thirty-six tools assessing intake of dairy, Ca or both, were identified. Reliability testing was conducted on only two dairy and five Ca tools, with results indicating that only one dairy and two Ca tools were reliable. Validity testing was conducted for all but four Ca-only tools. There was high reliance in validity testing on lower-order tests such as correlation and failure to differentiate between statistical and clinically meaningful differences. Results of the validity testing suggest one dairy and five Ca tools are valid. Thus one tool was considered both reliable and valid for the assessment of dairy intake and only two tools proved reliable and valid for the assessment of Ca intake. While several tools are reliable and valid, their application across adult populations is limited by the populations in which they were tested. These results indicate a need for tools that assess Ca and/or dairy intake in adults to be rigorously tested for reliability and validity.

  6. Reliability and availability analysis of a 10 kW@20 K helium refrigerator

    NASA Astrophysics Data System (ADS)

    Li, J.; Xiong, L. Y.; Liu, L. Q.; Wang, H. R.; Wang, B. M.

    2017-02-01

    A 10 kW@20 K helium refrigerator has been established in the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. To evaluate and improve this refrigerator’s reliability and availability, a reliability and availability analysis is performed. According to the mission profile of this refrigerator, a functional analysis is performed. The failure data of the refrigerator components are collected and failure rate distributions are fitted by software Weibull++ V10.0. A Failure Modes, Effects & Criticality Analysis (FMECA) is performed and the critical components with higher risks are pointed out. Software BlockSim V9.0 is used to calculate the reliability and the availability of this refrigerator. The result indicates that compressors, turbine and vacuum pump are the critical components and the key units of this refrigerator. The mitigation actions with respect to design, testing, maintenance and operation are proposed to decrease those major and medium risks.

  7. Probabilistic Assessment of High-Throughput Wireless Sensor Networks

    PubMed Central

    Kim, Robin E.; Mechitov, Kirill; Sim, Sung-Han; Spencer, Billie F.; Song, Junho

    2016-01-01

    Structural health monitoring (SHM) using wireless smart sensors (WSS) has the potential to provide rich information on the state of a structure. However, because of their distributed nature, maintaining highly robust and reliable networks can be challenging. Assessing WSS network communication quality before and after finalizing a deployment is critical to achieve a successful WSS network for SHM purposes. Early studies on WSS network reliability mostly used temporal signal indicators, composed of a smaller number of packets, to assess the network reliability. However, because the WSS networks for SHM purpose often require high data throughput, i.e., a larger number of packets are delivered within the communication, such an approach is not sufficient. Instead, in this study, a model that can assess, probabilistically, the long-term performance of the network is proposed. The proposed model is based on readily-available measured data sets that represent communication quality during high-throughput data transfer. Then, an empirical limit-state function is determined, which is further used to estimate the probability of network communication failure. Monte Carlo simulation is adopted in this paper and applied to a small and a full-bridge wireless networks. By performing the proposed analysis in complex sensor networks, an optimized sensor topology can be achieved. PMID:27258270

  8. Towards cost-effective reliability through visualization of the reliability option space

    NASA Technical Reports Server (NTRS)

    Feather, Martin S.

    2004-01-01

    In planning a complex system's development there can be many options to improve its reliability. Typically their sum total cost exceeds the budget available, so it is necessary to select judiciously from among them. Reliability models can be employed to calculate the cost and reliability implications of a candidate selection.

  9. Avionics Integrity Program (AVIP). Volume 1. Procurement Phase Issues - Design, Manufacturing, and Integration

    DTIC Science & Technology

    1984-03-01

    Engineering initiative to develop an orderly plan and procedure to assure that USAF acquire reliable, high quality, supportable avionics with a higher avail...susceptibility te~t~ (radiated and conducted), and emission of radio frequency energy tests."l6) Other electrical stresses can include over/under voltage...jo ints, poor welds, and dielectric defects. Also, instruments with components unable to endu very high temperatures can be safely tested. 1-19

  10. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips

    PubMed Central

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali

    2016-01-01

    Summary: Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable. PMID:27757342

  11. Enhancing recovery rates: lessons from year one of IAPT.

    PubMed

    Gyani, Alex; Shafran, Roz; Layard, Richard; Clark, David M

    2013-09-01

    The English Improving Access to Psychological Therapies (IAPT) initiative aims to make evidence-based psychological therapies for depression and anxiety disorder more widely available in the National Health Service (NHS). 32 IAPT services based on a stepped care model were established in the first year of the programme. We report on the reliable recovery rates achieved by patients treated in the services and identify predictors of recovery at patient level, service level, and as a function of compliance with National Institute of Health and Care Excellence (NICE) Treatment Guidelines. Data from 19,395 patients who were clinical cases at intake, attended at least two sessions, had at least two outcomes scores and had completed their treatment during the period were analysed. Outcome was assessed with the patient health questionnaire depression scale (PHQ-9) and the anxiety scale (GAD-7). Data completeness was high for a routine cohort study. Over 91% of treated patients had paired (pre-post) outcome scores. Overall, 40.3% of patients were reliably recovered at post-treatment, 63.7% showed reliable improvement and 6.6% showed reliable deterioration. Most patients received treatments that were recommended by NICE. When a treatment not recommended by NICE was provided, recovery rates were reduced. Service characteristics that predicted higher reliable recovery rates were: high average number of therapy sessions; higher step-up rates among individuals who started with low intensity treatment; larger services; and a larger proportion of experienced staff. Compliance with the IAPT clinical model is associated with enhanced rates of reliable recovery. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

    PubMed Central

    Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin

    2016-01-01

    Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196

  13. Report on Wind Turbine Subsystem Reliability - A Survey of Various Databases (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, S.

    2013-07-01

    Wind industry has been challenged by premature subsystem/component failures. Various reliability data collection efforts have demonstrated their values in supporting wind turbine reliability and availability research & development and industrial activities. However, most information on these data collection efforts are scattered and not in a centralized place. With the objective of getting updated reliability statistics of wind turbines and/or subsystems so as to benefit future wind reliability and availability activities, this report is put together based on a survey of various reliability databases that are accessible directly or indirectly by NREL. For each database, whenever feasible, a brief description summarizingmore » database population, life span, and data collected is given along with its features & status. Then selective results deemed beneficial to the industry and generated based on the database are highlighted. This report concludes with several observations obtained throughout the survey and several reliability data collection opportunities in the future.« less

  14. INFLUENCES OF RESPONSE RATE AND DISTRIBUTION ON THE CALCULATION OF INTEROBSERVER RELIABILITY SCORES

    PubMed Central

    Rolider, Natalie U.; Iwata, Brian A.; Bullock, Christopher E.

    2012-01-01

    We examined the effects of several variations in response rate on the calculation of total, interval, exact-agreement, and proportional reliability indices. Trained observers recorded computer-generated data that appeared on a computer screen. In Study 1, target responses occurred at low, moderate, and high rates during separate sessions so that reliability results based on the four calculations could be compared across a range of values. Total reliability was uniformly high, interval reliability was spuriously high for high-rate responding, proportional reliability was somewhat lower for high-rate responding, and exact-agreement reliability was the lowest of the measures, especially for high-rate responding. In Study 2, we examined the separate effects of response rate per se, bursting, and end-of-interval responding. Response rate and bursting had little effect on reliability scores; however, the distribution of some responses at the end of intervals decreased interval reliability somewhat, proportional reliability noticeably, and exact-agreement reliability markedly. PMID:23322930

  15. Highly Conductive and Reliable Copper-Filled Isotropically Conductive Adhesives Using Organic Acids for Oxidation Prevention

    NASA Astrophysics Data System (ADS)

    Chen, Wenjun; Deng, Dunying; Cheng, Yuanrong; Xiao, Fei

    2015-07-01

    The easy oxidation of copper is one critical obstacle to high-performance copper-filled isotropically conductive adhesives (ICAs). In this paper, a facile method to prepare highly reliable, highly conductive, and low-cost ICAs is reported. The copper fillers were treated by organic acids for oxidation prevention. Compared with ICA filled with untreated copper flakes, the ICA filled with copper flakes treated by different organic acids exhibited much lower bulk resistivity. The lowest bulk resistivity achieved was 4.5 × 10-5 Ω cm, which is comparable to that of commercially available Ag-filled ICA. After 500 h of 85°C/85% relative humidity (RH) aging, the treated ICAs showed quite stable bulk resistivity and relatively stable contact resistance. Through analyzing the results of x-ray diffraction, x-ray photoelectron spectroscopy, and thermogravimetric analysis, we found that, with the assistance of organic acids, the treated copper flakes exhibited resistance to oxidation, thus guaranteeing good performance.

  16. Energy recovery with turboexpander processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holm, J.

    1985-07-01

    Although the primary function of turboexpanders has been to provide efficient, low-temperature refrigeration, the energy thus extracted has also been an important additional feature. Today, turboexpanders are proven reliable and used widely in the following applications discussed in this article: industrial gases; natural gas (NG) processing; production of liquefied natural gas (LNG); flashing hydrocarbon liquids; NG pressure letdown energy recovery; oilfield cogeneration; and recovery of energy from waste heat. Turboexpander applications for energy conservation resulted because available turboexpanders have the required high-performance capabilities and reliability. At the same time, the development of these energy conservation practices and processes helped furthermore » improve turboexpanders.« less

  17. Maximally reliable spatial filtering of steady state visual evoked potentials.

    PubMed

    Dmochowski, Jacek P; Greaves, Alex S; Norcia, Anthony M

    2015-04-01

    Due to their high signal-to-noise ratio (SNR) and robustness to artifacts, steady state visual evoked potentials (SSVEPs) are a popular technique for studying neural processing in the human visual system. SSVEPs are conventionally analyzed at individual electrodes or linear combinations of electrodes which maximize some variant of the SNR. Here we exploit the fundamental assumption of evoked responses--reproducibility across trials--to develop a technique that extracts a small number of high SNR, maximally reliable SSVEP components. This novel spatial filtering method operates on an array of Fourier coefficients and projects the data into a low-dimensional space in which the trial-to-trial spectral covariance is maximized. When applied to two sample data sets, the resulting technique recovers physiologically plausible components (i.e., the recovered topographies match the lead fields of the underlying sources) while drastically reducing the dimensionality of the data (i.e., more than 90% of the trial-to-trial reliability is captured in the first four components). Moreover, the proposed technique achieves a higher SNR than that of the single-best electrode or the Principal Components. We provide a freely-available MATLAB implementation of the proposed technique, herein termed "Reliable Components Analysis". Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Smart photonic networks and computer security for image data

    NASA Astrophysics Data System (ADS)

    Campello, Jorge; Gill, John T.; Morf, Martin; Flynn, Michael J.

    1998-02-01

    Work reported here is part of a larger project on 'Smart Photonic Networks and Computer Security for Image Data', studying the interactions of coding and security, switching architecture simulations, and basic technologies. Coding and security: coding methods that are appropriate for data security in data fusion networks were investigated. These networks have several characteristics that distinguish them form other currently employed networks, such as Ethernet LANs or the Internet. The most significant characteristics are very high maximum data rates; predominance of image data; narrowcasting - transmission of data form one source to a designated set of receivers; data fusion - combining related data from several sources; simple sensor nodes with limited buffering. These characteristics affect both the lower level network design and the higher level coding methods.Data security encompasses privacy, integrity, reliability, and availability. Privacy, integrity, and reliability can be provided through encryption and coding for error detection and correction. Availability is primarily a network issue; network nodes must be protected against failure or routed around in the case of failure. One of the more promising techniques is the use of 'secret sharing'. We consider this method as a special case of our new space-time code diversity based algorithms for secure communication. These algorithms enable us to exploit parallelism and scalable multiplexing schemes to build photonic network architectures. A number of very high-speed switching and routing architectures and their relationships with very high performance processor architectures were studied. Indications are that routers for very high speed photonic networks can be designed using the very robust and distributed TCP/IP protocol, if suitable processor architecture support is available.

  19. Chapter 15: Reliability of Wind Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Shuangwen; O'Connor, Ryan

    The global wind industry has witnessed exciting developments in recent years. The future will be even brighter with further reductions in capital and operation and maintenance costs, which can be accomplished with improved turbine reliability, especially when turbines are installed offshore. One opportunity for the industry to improve wind turbine reliability is through the exploration of reliability engineering life data analysis based on readily available data or maintenance records collected at typical wind plants. If adopted and conducted appropriately, these analyses can quickly save operation and maintenance costs in a potentially impactful manner. This chapter discusses wind turbine reliability bymore » highlighting the methodology of reliability engineering life data analysis. It first briefly discusses fundamentals for wind turbine reliability and the current industry status. Then, the reliability engineering method for life analysis, including data collection, model development, and forecasting, is presented in detail and illustrated through two case studies. The chapter concludes with some remarks on potential opportunities to improve wind turbine reliability. An owner and operator's perspective is taken and mechanical components are used to exemplify the potential benefits of reliability engineering analysis to improve wind turbine reliability and availability.« less

  20. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 5. Technical Report #1204

    ERIC Educational Resources Information Center

    Park, Bitnara Jasmine; Irvin, P. Shawn; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fifth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  1. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 2. Technical Report #1201

    ERIC Educational Resources Information Center

    Lai, Cheng-Fei; Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the second-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  2. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 4. Technical Report #1203

    ERIC Educational Resources Information Center

    Park, Bitnara Jasmine; Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fourth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  3. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 6. Technical Report #1205

    ERIC Educational Resources Information Center

    Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the sixth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  4. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 7. Technical Report #1206

    ERIC Educational Resources Information Center

    Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the seventh-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  5. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 3. Technical Report #1202

    ERIC Educational Resources Information Center

    Lai, Cheng-Fei; Irvin, P. Shawn; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the third-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  6. Validation of the Fatigue Impact Scale in Hungarian patients with multiple sclerosis.

    PubMed

    Losonczi, Erika; Bencsik, Krisztina; Rajda, Cecília; Lencsés, Gyula; Török, Margit; Vécsei, László

    2011-03-01

    Fatigue is one of the most frequent complaints of patients with multiple sclerosis (MS). The Fatigue Impact Scale (FIS), one of the 30 available fatigue questionnaires, is commonly applied because it evaluates multidimensional aspects of fatigue. The main purposes of this study were to test the validity, test-retest reliability, and internal consistency of the Hungarian version of the FIS. One hundred and eleven MS patients and 85 healthy control (HC) subjects completed the FIS and the Beck Depression Inventory, a large majority of them on two occasions, 3 months apart. The total FIS score and subscale scores differed statistically between the MS patients and the HC subjects in both FIS sessions. In the test-retest reliability assessment, statistically, the intraclass correlation coefficients were high in both the MS and HC groups. Cronbach's alpha values were also notably high. The results of this study indicate that the FIS can be regarded as a valid and reliable scale with which to improve our understanding of the impact of fatigue on the health-related quality of life in MS patients without severe disability.

  7. Development and Reliability Testing of a Fast-Food Restaurant Observation Form.

    PubMed

    Rimkus, Leah; Ohri-Vachaspati, Punam; Powell, Lisa M; Zenk, Shannon N; Quinn, Christopher M; Barker, Dianne C; Pugach, Oksana; Resnick, Elissa A; Chaloupka, Frank J

    2015-01-01

    To develop a reliable observational data collection instrument to measure characteristics of the fast-food restaurant environment likely to influence consumer behaviors, including product availability, pricing, and promotion. The study used observational data collection. Restaurants were in the Chicago Metropolitan Statistical Area. A total of 131 chain fast-food restaurant outlets were included. Interrater reliability was measured for product availability, pricing, and promotion measures on a fast-food restaurant observational data collection instrument. Analysis was done with Cohen's κ coefficient and proportion of overall agreement for categorical variables and intraclass correlation coefficient (ICC) for continuous variables. Interrater reliability, as measured by average κ coefficient, was .79 for menu characteristics, .84 for kids' menu characteristics, .92 for food availability and sizes, .85 for beverage availability and sizes, .78 for measures on the availability of nutrition information,.75 for characteristics of exterior advertisements, and .62 and .90 for exterior and interior characteristics measures, respectively. For continuous measures, average ICC was .88 for food pricing measures, .83 for beverage prices, and .65 for counts of exterior advertisements. Over 85% of measures demonstrated substantial or almost perfect agreement. Although some measures required revision or protocol clarification, results from this study suggest that the instrument may be used to reliably measure the fast-food restaurant environment.

  8. Accuracy and reliability of Chile's National Air Quality Information System for measuring particulate matter: Beta attenuation monitoring issue.

    PubMed

    Toro A, Richard; Campos, Claudia; Molina, Carolina; Morales S, Raul G E; Leiva-Guzmán, Manuel A

    2015-09-01

    A critical analysis of Chile's National Air Quality Information System (NAQIS) is presented, focusing on particulate matter (PM) measurement. This paper examines the complexity, availability and reliability of monitoring station information, the implementation of control systems, the quality assurance protocols of the monitoring station data and the reliability of the measurement systems in areas highly polluted by particulate matter. From information available on the NAQIS website, it is possible to confirm that the PM2.5 (PM10) data available on the site correspond to 30.8% (69.2%) of the total information available from the monitoring stations. There is a lack of information regarding the measurement systems used to quantify air pollutants, most of the available data registers contain gaps, almost all of the information is categorized as "preliminary information" and neither standard operating procedures (operational and validation) nor assurance audits or quality control of the measurements are reported. In contrast, events that cause saturation of the monitoring detectors located in northern and southern Chile have been observed using beta attenuation monitoring. In these cases, it can only be concluded that the PM content is equal to or greater than the saturation concentration registered by the monitors and that the air quality indexes obtained from these measurements are underestimated. This occurrence has been observed in 12 (20) public and private stations where PM2.5 (PM10) is measured. The shortcomings of the NAQIS data have important repercussions for the conclusions obtained from the data and for how the data are used. However, these issues represent opportunities for improving the system to widen its use, incorporate comparison protocols between equipment, install new stations and standardize the control system and quality assurance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Preliminary Evidence for the Validity of the New Test of Everyday Reading Comprehension

    ERIC Educational Resources Information Center

    Wheldall, Kevin; McMurtry, Sarah

    2014-01-01

    The Test of Everyday Reading Comprehension (TERC) has recently been presented as an addition to the armoury of tests available for assessing the skills of low-progress readers. While comparison data for students of different ages are presented together with evidence for high test reliability, there is, as yet, no published evidence for its…

  10. A reliable methodology for quantitative extraction of fruit and vegetable physiological amino acids and their subsequent analysis with commonly available HPLC systems

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography of dabsyl derivatives of amino acids was employed for quantification of physiological amino acids in selected fruits and vegetables. This method was found to be particularly useful because the dabsyl derivatives of glutamine and citrulline were sufficiently se...

  11. Stress Responses and Decision Making in Child Protection Workers Faced with High Conflict Situations

    ERIC Educational Resources Information Center

    LeBlanc, Vicki R.; Regehr, Cheryl; Shlonsky, Aron; Bogo, Marion

    2012-01-01

    Introduction: The assessment of children at risk of abuse and neglect is a critical societal function performed by child protection workers in situations of acute stress and conflict. Despite efforts to improve the reliability of risk assessments through standardized measures, available tools continue to rely on subjective judgment. The goal of…

  12. Monitoring visitor use in backcountry and wilderness: a review of methods

    Treesearch

    Steven J. Hollenhorst; Steven A. Whisman; Alan W. Ewert

    1992-01-01

    Obtaining accurate and usable visitor counts in backcountry and wilderness settings continues to be problematic for resource managers because use of these areas is dispersed and costs can be prohibitively high. An overview of the available methods for obtaining reliable data on recreation use levels is provided. Monitoring methods were compared and selection criteria...

  13. Direct-current converter for gas-discharge lamps

    NASA Technical Reports Server (NTRS)

    Lutus, P.

    1980-01-01

    Metal/halide and similar gas-discharge lamps are powered from low-voltage dc source using small efficient converter. Converter is useful whenever 60-cycle ac power is not available or where space and weight allocations are limited. Possible applications are offshore platforms, mobile homes, and emergency lighting. Design innovations give supply high reliability and efficiency up to 75 percent.

  14. Reliability of physical examination for diagnosis of myofascial trigger points: a systematic review of the literature.

    PubMed

    Lucas, Nicholas; Macaskill, Petra; Irwig, Les; Moran, Robert; Bogduk, Nikolai

    2009-01-01

    Trigger points are promoted as an important cause of musculoskeletal pain. There is no accepted reference standard for the diagnosis of trigger points, and data on the reliability of physical examination for trigger points are conflicting. To systematically review the literature on the reliability of physical examination for the diagnosis of trigger points. MEDLINE, EMBASE, and other sources were searched for articles reporting the reliability of physical examination for trigger points. Included studies were evaluated for their quality and applicability, and reliability estimates were extracted and reported. Nine studies were eligible for inclusion. None satisfied all quality and applicability criteria. No study specifically reported reliability for the identification of the location of active trigger points in the muscles of symptomatic participants. Reliability estimates varied widely for each diagnostic sign, for each muscle, and across each study. Reliability estimates were generally higher for subjective signs such as tenderness (kappa range, 0.22-1.0) and pain reproduction (kappa range, 0.57-1.00), and lower for objective signs such as the taut band (kappa range, -0.08-0.75) and local twitch response (kappa range, -0.05-0.57). No study to date has reported the reliability of trigger point diagnosis according to the currently proposed criteria. On the basis of the limited number of studies available, and significant problems with their design, reporting, statistical integrity, and clinical applicability, physical examination cannot currently be recommended as a reliable test for the diagnosis of trigger points. The reliability of trigger point diagnosis needs to be further investigated with studies of high quality that use current diagnostic criteria in clinically relevant patients.

  15. Ultra-barcoding in cacao (Theobroma spp.; Malvaceae) using whole chloroplast genomes and nuclear ribosomal DNA.

    PubMed

    Kane, Nolan; Sveinsson, Saemundur; Dempewolf, Hannes; Yang, Ji Yong; Zhang, Dapeng; Engels, Johannes M M; Cronk, Quentin

    2012-02-01

    To reliably identify lineages below the species level such as subspecies or varieties, we propose an extension to DNA-barcoding using next-generation sequencing to produce whole organellar genomes and substantial nuclear ribosomal sequence. Because this method uses much longer versions of the traditional DNA-barcoding loci in the plastid and ribosomal DNA, we call our approach ultra-barcoding (UBC). We used high-throughput next-generation sequencing to scan the genome and generate reliable sequence of high copy number regions. Using this method, we examined whole plastid genomes as well as nearly 6000 bases of nuclear ribosomal DNA sequences for nine genotypes of Theobroma cacao and an individual of the related species T. grandiflorum, as well as an additional publicly available whole plastid genome of T. cacao. All individuals of T. cacao examined were uniquely distinguished, and evidence of reticulation and gene flow was observed. Sequence variation was observed in some of the canonical barcoding regions between species, but other regions of the chloroplast were more variable both within species and between species, as were ribosomal spacers. Furthermore, no single region provides the level of data available using the complete plastid genome and rDNA. Our data demonstrate that UBC is a viable, increasingly cost-effective approach for reliably distinguishing varieties and even individual genotypes of T. cacao. This approach shows great promise for applications where very closely related or interbreeding taxa must be distinguished.

  16. The development of a reliable amateur boxing performance analysis template.

    PubMed

    Thomson, Edward; Lamb, Kevin; Nicholas, Ceri

    2013-01-01

    The aim of this study was to devise a valid performance analysis system for the assessment of the movement characteristics associated with competitive amateur boxing and assess its reliability using analysts of varying experience of the sport and performance analysis. Key performance indicators to characterise the demands of an amateur contest (offensive, defensive and feinting) were developed and notated using a computerised notational analysis system. Data were subjected to intra- and inter-observer reliability assessment using median sign tests and calculating the proportion of agreement within predetermined limits of error. For all performance indicators, intra-observer reliability revealed non-significant differences between observations (P > 0.05) and high agreement was established (80-100%) regardless of whether exact or the reference value of ±1 was applied. Inter-observer reliability was less impressive for both analysts (amateur boxer and experienced analyst), with the proportion of agreement ranging from 33-100%. Nonetheless, there was no systematic bias between observations for any indicator (P > 0.05), and the proportion of agreement within the reference range (±1) was 100%. A reliable performance analysis template has been developed for the assessment of amateur boxing performance and is available for use by researchers, coaches and athletes to classify and quantify the movement characteristics of amateur boxing.

  17. Spanish version validation of the Marihuana Motives Measure in a drug-consuming adolescent sample.

    PubMed

    Matali Costa, Josep; Simons, J; Pardo, M; Lleras, M; Pérez, A; Andión, O

    2018-01-15

    Cannabis is the illicit drug mostly widely consumed by adolescents in Spain. The understanding of consumption motives is an important factor for intervention. In Spain, there are no available instruments for their evaluation, hence, the goal of this paper is to study the psychometric properties of the Marihuana Motives Measure (MMM) in a sample of adolescent consumers. Firstly, translation and back-translation was performed. A total of 228 adolescent consumers of cannabis were evaluated. Factorial analysis was conducted, and the reliability of the total scores and of each scale of the questionnaire was studied through Cronbach's alpha. Test-retest reliability was analyzed through interclass correlations. Validity evidence of the MMM was examined through correlations between current cannabis use, subjective consumption effects measured with the Addiction Research Center Inventory (ARCI), and personality measured with the Millon Adolescent Clinical Inventory (MACI). High reliability was observed in total score of the MMM (Cronbach α = .86), and high and moderate reliability for each of the five factors obtained in the factorial analysis of the MMM, Social = .82, Enhancement = .72, Coping = .83, Expansion = .74, and Conformity = .64. Significant correlations were also observed between cannabis consumption motives and subjective effects, and between consumption motives and personality. The Spanish version of the MMM shows a similar factorial structure as the one obtained by the original author, and its measures are reliable and valid for the study of cannabis consumption motives in adolescent consumer population.

  18. The Alcohol Use Disorder and Associated Disabilities Interview Schedule-IV (AUDADIS-IV): Reliability of New Psychiatric Diagnostic Modules and Risk Factors in a General Population Sample

    PubMed Central

    Ruan, W. June; Goldstein, Risë B.; Chou, S. Patricia; Smith, Sharon M.; Saha, Tulshi D.; Pickering, Roger P.; Dawson, Deborah A.; Huang, Boji; Stinson, Frederick S.; Grant, Bridget F.

    2008-01-01

    This study presents test-retest reliability statistics and information on internal consistency for new diagnostic modules and risk factor of alcohol, drug, and psychiatric disorders the Alcohol Use Disorder and Associated Disabilities Interview Schedule-IV (AUDADIS-IV). Test-retest statistics were derived from a random sample of 1,899 adults selected from 34,653 respondents who participated in the 2004–2005 Wave 2 National Epidemiologic Survey on Alcohol and Related Conditions (NESARC). Internal consistency of continuous scales was assessed using the entire Wave 2 NESARC. Both test and retest interviews were conducted face-to-face. Test-retest and internal consistency results for diagnoses and symptom scales associated with posttraumatic stress disorder, attention-deficit/hyperactivity disorder, and borderline, narcissistic, and schizotypal personality disorders were predominantly good (kappa > 0.63; ICC > 0.69; alpha > 0.75) and reliability for risk factor measures fell within the good to excellent range (intraclass correlations = 0.50–0.94; alpha = 0.64–0.90). The high degree of reliability found in this study suggests that new AUDADIS-IV diagnostic measures can be useful tools in research settings. The availability of highly reliable measures of risk factors of alcohol, drug, and psychiatric disorders will contribute to the validity of conclusions drawn from future research in the domains of substance use disorder and psychiatric epidemiology. PMID:17706375

  19. Investigation of the 68Zn(p, 2p) 67Cu nuclear reaction: New measurements up to 40 MeV and compilation up to 100 MeV

    NASA Astrophysics Data System (ADS)

    Szelecsényi, F.; Steyn, G. F.; Dolley, S. G.; Kovács, Z.; Vermeulen, C.; van der Walt, T. N.

    2009-06-01

    The excitation function was measured for the 68Zn(p, 2p) 67Cu nuclear reaction from its threshold energy up to 40 MeV. Nine pieces of highly enriched 68Zn (>98%) metal foils were irradiated to obtain reliable cross-sections using the usual stacked-foil technique. All foils were subjected to high efficiency radiochemical separation before the activity measurements. A critical compilation of the available experimental cross-section results was also performed. Thick target yields of 67Cu and the longer-lived copper radio-contaminants ( 61Cu and 64Cu) were calculated using the reliable literature results up to 100 MeV. Additionally, EOB (End Of Bombardment) contamination levels as a function of bombarding energy and irradiation time were deduced.

  20. An efficient, reliable and inexpensive device for the rapid homogenization of multiple tissue samples by centrifugation.

    PubMed

    Ilyin, S E; Plata-Salamán, C R

    2000-02-15

    Homogenization of tissue samples is a common first step in the majority of current protocols for RNA, DNA, and protein isolation. This report describes a simple device for centrifugation-mediated homogenization of tissue samples. The method presented is applicable to RNA, DNA, and protein isolation, and we show examples where high quality total cell RNA, DNA, and protein were obtained from brain and other tissue samples. The advantages of the approach presented include: (1) a significant reduction in time investment relative to hand-driven or individual motorized-driven pestle homogenization; (2) easy construction of the device from inexpensive parts available in any laboratory; (3) high replicability in the processing; and (4) the capacity for the parallel processing of multiple tissue samples, thus allowing higher efficiency, reliability, and standardization.

  1. Teaching DSM-III to clinicians. Some problems of the DSM-III system reducing reliability, using the diagnosis and classification of depressive disorders as an example.

    PubMed

    Malt, U F

    1986-01-01

    Experiences from teaching DSM-III to more than three hundred Norwegian psychiatrists and clinical psychologists suggest that reliable DSM-III diagnoses can be achieved within a few hours training with reference to the decision trees and the diagnostic criteria only. The diagnoses provided are more reliable than the corresponding ICD diagnoses which the participants were more familiar with. The three main sources of reduced reliability of the DSM-III diagnoses are related to: poor knowledge of the criteria which often is connected with failure of obtaining diagnostic key information during the clinical interview; unfamiliar concepts and vague or ambiguous criteria. The two first issues are related to the quality of the teaching of DSM-III. The third source of reduced reliability reflects unsolved validity issues. By using the classification of five affective case stories as examples, these sources of diagnostic pitfalls, reducing reliability and ways to overcome these problems when teaching the DSM-III system, are discussed. It is concluded that the DSM-III system of classification is easy to teach and that the system is superior to other classification systems available from a reliability point of view. The current version of the DSM-III system, however, partly owes a high degree of reliability to broad and heterogeneous diagnostic categories like the concept major depression, which may have questionable validity. Thus, the future revisions of the DSM-III system should, above all, address the issue of validity.

  2. Are cannabis prevalence estimates comparable across countries and regions? A cross-cultural validation using search engine query data.

    PubMed

    Steppan, Martin; Kraus, Ludwig; Piontek, Daniela; Siciliano, Valeria

    2013-01-01

    Prevalence estimation of cannabis use is usually based on self-report data. Although there is evidence on the reliability of this data source, its cross-cultural validity is still a major concern. External objective criteria are needed for this purpose. In this study, cannabis-related search engine query data are used as an external criterion. Data on cannabis use were taken from the 2007 European School Survey Project on Alcohol and Other Drugs (ESPAD). Provincial data came from three Italian nation-wide studies using the same methodology (2006-2008; ESPAD-Italia). Information on cannabis-related search engine query data was based on Google search volume indices (GSI). (1) Reliability analysis was conducted for GSI. (2) Latent measurement models of "true" cannabis prevalence were tested using perceived availability, web-based cannabis searches and self-reported prevalence as indicators. (3) Structure models were set up to test the influences of response tendencies and geographical position (latitude, longitude). In order to test the stability of the models, analyses were conducted on country level (Europe, US) and on provincial level in Italy. Cannabis-related GSI were found to be highly reliable and constant over time. The overall measurement model was highly significant in both data sets. On country level, no significant effects of response bias indicators and geographical position on perceived availability, web-based cannabis searches and self-reported prevalence were found. On provincial level, latitude had a significant positive effect on availability indicating that perceived availability of cannabis in northern Italy was higher than expected from the other indicators. Although GSI showed weaker associations with cannabis use than perceived availability, the findings underline the external validity and usefulness of search engine query data as external criteria. The findings suggest an acceptable relative comparability of national (provincial) prevalence estimates of cannabis use that are based on a common survey methodology. Search engine query data are a too weak indicator to base prevalence estimations on this source only, but in combination with other sources (waste water analysis, sales of cigarette paper) they may provide satisfactory estimates. Copyright © 2012. Published by Elsevier B.V.

  3. Reliability of Degree-Day Models to Predict the Development Time of Plutella xylostella (L.) under Field Conditions.

    PubMed

    Marchioro, C A; Krechemer, F S; de Moraes, C P; Foerster, L A

    2015-12-01

    The diamondback moth, Plutella xylostella (L.), is a cosmopolitan pest of brassicaceous crops occurring in regions with highly distinct climate conditions. Several studies have investigated the relationship between temperature and P. xylostella development rate, providing degree-day models for populations from different geographical regions. However, there are no data available to date to demonstrate the suitability of such models to make reliable projections on the development time for this species in field conditions. In the present study, 19 models available in the literature were tested regarding their ability to accurately predict the development time of two cohorts of P. xylostella under field conditions. Only 11 out of the 19 models tested accurately predicted the development time for the first cohort of P. xylostella, but only seven for the second cohort. Five models correctly predicted the development time for both cohorts evaluated. Our data demonstrate that the accuracy of the models available for P. xylostella varies widely and therefore should be used with caution for pest management purposes.

  4. Durability reliability analysis for corroding concrete structures under uncertainty

    NASA Astrophysics Data System (ADS)

    Zhang, Hao

    2018-02-01

    This paper presents a durability reliability analysis of reinforced concrete structures subject to the action of marine chloride. The focus is to provide insight into the role of epistemic uncertainties on durability reliability. The corrosion model involves a number of variables whose probabilistic characteristics cannot be fully determined due to the limited availability of supporting data. All sources of uncertainty, both aleatory and epistemic, should be included in the reliability analysis. Two methods are available to formulate the epistemic uncertainty: the imprecise probability-based method and the purely probabilistic method in which the epistemic uncertainties are modeled as random variables. The paper illustrates how the epistemic uncertainties are modeled and propagated in the two methods, and shows how epistemic uncertainties govern the durability reliability.

  5. A Designers’ Guide to Reliable Distributed Systems: Design and Analysis Methods. An Example Design. Volume 1

    DTIC Science & Technology

    1988-08-01

    exchanged between the cells, thus requiring existence of fast , high capacity, high availability communication channels. The same arguments indicate...mininet - loss of a cell - intermittent communications failure in the maxinet - partitioning of the maxinet or the mininet o Query decomposition. 3.3...take place. A new sequencer is selected by the timeout mechanism described above. This process Pj must set its priority to 0 in order to ensure fast

  6. Market assessment of photovoltaic power systems for agricultural applications in Nigeria

    NASA Technical Reports Server (NTRS)

    Staples, D.; Steingass, H.; Nolfi, J.

    1981-01-01

    The market potential for stand-alone photovoltaic systems in agriculture was studied. Information is presented on technical and economically feasible applications, and assessments of the business, government and financial climate for photovoltaic sales. It is concluded that the market for stand-alone systems will be large because of the availability of captial and the high premium placed on high reliability, low maintenance power systems. Various specific applications are described, mostly related to agriculture.

  7. Market assessment of photovoltaic power systems for agricultural applications in Nigeria

    NASA Astrophysics Data System (ADS)

    Staples, D.; Steingass, H.; Nolfi, J.

    1981-10-01

    The market potential for stand-alone photovoltaic systems in agriculture was studied. Information is presented on technical and economically feasible applications, and assessments of the business, government and financial climate for photovoltaic sales. It is concluded that the market for stand-alone systems will be large because of the availability of captial and the high premium placed on high reliability, low maintenance power systems. Various specific applications are described, mostly related to agriculture.

  8. 75 FR 5633 - Notice of Extension of Comment Period for NUREG-1921, EPRI/NRC-RES Fire Human Reliability...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-03

    ..., EPRI/NRC- RES Fire Human Reliability Analysis Guidelines, Draft Report for Comment AGENCY: Nuclear... Human Reliability Analysis Guidelines, Draft Report for Comment'' (December 11, 2009; 74 FR 65810). This... Human Reliability Analysis Guidelines'' is available electronically under ADAMS Accession Number...

  9. Familiarization, validity and smallest detectable difference of the isometric squat test in evaluating maximal strength.

    PubMed

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2018-02-06

    Isometric multi-joint tests are considered reliable and have strong relationships with 1RM performance. However, limited evidence is available for the isometric squat in terms of effects of familiarization and reliability. This study aimed to assess, the effect of familiarization, stability reliability, determine the smallest detectible difference, and the correlation of the isometric squat test with 1RM squat performance. Thirty-six strength-trained participants volunteered to take part in this study. Following three familiarization sessions, test-retest reliability was evaluated with a 48-hour window between each time point. Isometric squat peak, net and relative force were assessed. Results showed three familiarizations were required, isometric squat had a high level of stability reliability and smallest detectible difference of 11% for peak and relative force. Isometric strength at a knee angle of ninety degrees had a strong significant relationship with 1RM squat performance. In conclusion, the isometric squat is a valid test to assess multi-joint strength and can discriminate between strong and weak 1RM squat performance. Changes greater than 11% in peak and relative isometric squat performance should be considered as meaningful in participants who are familiar with the test.

  10. Design and implementation of a reliable and cost-effective cloud computing infrastructure: the INFN Napoli experience

    NASA Astrophysics Data System (ADS)

    Capone, V.; Esposito, R.; Pardi, S.; Taurino, F.; Tortone, G.

    2012-12-01

    Over the last few years we have seen an increasing number of services and applications needed to manage and maintain cloud computing facilities. This is particularly true for computing in high energy physics, which often requires complex configurations and distributed infrastructures. In this scenario a cost effective rationalization and consolidation strategy is the key to success in terms of scalability and reliability. In this work we describe an IaaS (Infrastructure as a Service) cloud computing system, with high availability and redundancy features, which is currently in production at INFN-Naples and ATLAS Tier-2 data centre. The main goal we intended to achieve was a simplified method to manage our computing resources and deliver reliable user services, reusing existing hardware without incurring heavy costs. A combined usage of virtualization and clustering technologies allowed us to consolidate our services on a small number of physical machines, reducing electric power costs. As a result of our efforts we developed a complete solution for data and computing centres that can be easily replicated using commodity hardware. Our architecture consists of 2 main subsystems: a clustered storage solution, built on top of disk servers running GlusterFS file system, and a virtual machines execution environment. GlusterFS is a network file system able to perform parallel writes on multiple disk servers, providing this way live replication of data. High availability is also achieved via a network configuration using redundant switches and multiple paths between hypervisor hosts and disk servers. We also developed a set of management scripts to easily perform basic system administration tasks such as automatic deployment of new virtual machines, adaptive scheduling of virtual machines on hypervisor hosts, live migration and automated restart in case of hypervisor failures.

  11. Evaluation of a simple test of reaction time for baseline concussion testing in a population of high school athletes.

    PubMed

    MacDonald, James; Wilson, Julie; Young, Julie; Duerson, Drew; Swisher, Gail; Collins, Christy L; Meehan, William P

    2015-01-01

    A common sequela of concussions is impaired reaction time. Computerized neurocognitive tests commonly measure reaction time. A simple clinical test for reaction time has been studied previously in college athletes; whether this test is valid and reliable when assessing younger athletes remains unknown. Our study examines the reliability and validity of this test in a population of high school athletes. Cross-sectional study. Two American High Schools. High school athletes (N = 448) participating in American football or soccer during the academic years 2011 to 2012 and 2012 to 2013. All study participants completed a computerized baseline neurocognitive assessment that included a measure of reaction time (RT comp), in addition to a clinical measure of reaction time that assessed how far a standard measuring device would fall prior to the athlete catching it (RT clin). Validity was assessed by determining the correlation between RT clin and RT comp. Reliability was assessed by measuring the intraclass correlation coefficients (ICCs) between the repeated measures of RT clin and RT comp taken 1 year apart. In the first year of study, RT clin and RT comp were positively but weakly correlated (rs = 0.229, P < 0.001). In the second year, there was no significant correlation between RT clin and RT comp (rs = 0.084, P = 0.084). Both RT clin [ICC = 0.608; 95% confidence interval (CI), 0.434-0.728] and RT comp (ICC = 0.691; 95% CI, 0.554-0.786) had marginal reliability. In a population of high school athletes, RT clin had poor validity when compared with RT comp as a standard. Both RT clin and RT comp had marginal test-retest reliability. Before considering the clinical use of RT clin in the assessment of sport-related concussions sustained by high school athletes, the factors affecting reliability and validity should be investigated further. Reaction time impairment commonly results from concussion and is among the most clinically important measures of the condition. The device evaluated in this study has previously been investigated as a reaction time measure in college athletes. This study investigates the clinical generalizability of the device in a younger population. A video abstract showing how the RT clin device is used in practice is available as Supplemental Digital Content 1, http://links.lww.com/JSM/A43.

  12. Development of novel technologies to enhance performance and reliability of III-Nitride avalanche photodiodes

    NASA Astrophysics Data System (ADS)

    Suvarna, Puneet Harischandra

    Solar-blind ultraviolet avalanche photodiodes are an enabling technology for applications in the fields of astronomy, communication, missile warning systems, biological agent detection and particle physics research. Avalanche photodiodes (APDs) are capable of detecting low-intensity light with high quantum efficiency and signal-to-noise ratio without the need for external amplification. The properties of III-N materials (GaN and AlGaN) are promising for UV photodetectors that are highly efficient, radiation-hard and capable of visible-blind or solar-blind operation without the need for external filters. However, the realization of reliable and high performance III-N APDs and imaging arrays has several technological challenges. The high price and lack of availability of bulk III-N substrates necessitates the growth of III-Ns on lattice mismatched substrates leading to a high density of dislocations in the material that can cause high leakage currents, noise and premature breakdown in APDs. The etched sidewalls of III-N APDs and high electric fields at contact edges are also detrimental to APD performance and reliability. In this work, novel technologies have been developed and implemented that address the issues of performance and reliability in III-Nitride based APDs. To address the issue of extended defects in the bulk of the material, a novel pulsed MOCVD process was developed for the growth of AlGaN. This process enables growth of high crystal quality AlxGa1-xN with excellent control over composition, doping and thickness. The process has also been adapted for the growth of high quality III-N materials on silicon substrate for devices such as high electron mobility transistors (HEMTs). A novel post-growth defect isolation technique is also discussed that can isolate the impact of conductive defects from devices. A new sidewall passivation technique using atomic layer deposition (ALD) of dielectric materials was developed for III-N APDs that is effective in reducing the dark-current and trap states at sidewalls by close to an order of magnitude, leading to improved APD performance. Development and implementation of an ion implantation based contact edge termination technique for III-N APDs that helps prevent premature breakdown from the contact edge of the devices, has further lead to improved reliability. Finally novel improved III-N APD device designs are proposed using preliminary experiments and numerical simulations for future implementations.

  13. A highly resilient mesoporous SiOx lithium storage material engineered by oil-water templating.

    PubMed

    Park, Eunjun; Park, Min-Sik; Lee, Jaewoo; Kim, Ki Jae; Jeong, Goojin; Kim, Jung Ho; Kim, Young-Jun; Kim, Hansu

    2015-02-01

    Mesoporous silicon-based materials gained considerable attention as high-capacity lithium-storage materials. However, the practical use is still limited by the complexity and limited number of available synthetic routes. Here, we report carbon-coated porous SiOx as high capacity lithium storage material prepared by using a sol-gel reaction of hydrogen silsesquioxane and oil-water templating. A hydrophobic oil is employed as a pore former inside the SiOx matrix and a precursor for carbon coating on the SiOx . The anode exhibits a high capacity of 730 mAh g(-1) and outstanding cycling performance over 100 cycles without significant dimensional changes. Carbon-coated porous SiOx also showed highly stable thermal reliability comparable to that of graphite. These promising properties come from the mesopores in the SiOx matrix, which ensures reliable operation of lithium storage in SiOx . The scalable sol-gel process presented here can open up a new avenue for the versatile preparation of porous SiOx lithium storage materials. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A High Resolution Scale-of-four

    DOE R&D Accomplishments Database

    Fitch, V.

    1949-08-25

    A high resolution scale-of-four has been developed to be used in conjunction with the nuclear particle detection devices in applications where the counting rate is unusually high. Specifically, it is intended to precede the commercially available medium resolution scaling circuits and so decrease the resolving time of the counting system. The circuit will function reliably on continuously recurring pulses separated by less than 0.1 microseconds. It will resolve two pulses (occurring at a moderate repetition rate) which are spaced at 0.04 microseconds. A five-volt input signal is sufficient to actuate the device.

  15. Uncertainties in obtaining high reliability from stress-strength models

    NASA Technical Reports Server (NTRS)

    Neal, Donald M.; Matthews, William T.; Vangel, Mark G.

    1992-01-01

    There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.

  16. Digital assessment of the fetal alcohol syndrome facial phenotype: reliability and agreement study.

    PubMed

    Tsang, Tracey W; Laing-Aiken, Zoe; Latimer, Jane; Fitzpatrick, James; Oscar, June; Carter, Maureen; Elliott, Elizabeth J

    2017-01-01

    To examine the three facial features of fetal alcohol syndrome (FAS) in a cohort of Australian Aboriginal children from two-dimensional digital facial photographs to: (1) assess intrarater and inter-rater reliability; (2) identify the racial norms with the best fit for this population; and (3) assess agreement with clinician direct measures. Photographs and clinical data for 106 Aboriginal children (aged 7.4-9.6 years) were sourced from the Lililwan Project . Fifty-eight per cent had a confirmed prenatal alcohol exposure and 13 (12%) met the Canadian 2005 criteria for FAS/partial FAS. Photographs were analysed using the FAS Facial Photographic Analysis Software to generate the mean PFL three-point ABC-Score, five-point lip and philtrum ranks and four-point face rank in accordance with the 4-Digit Diagnostic Code. Intrarater and inter-rater reliability of digital ratings was examined in two assessors. Caucasian or African American racial norms for PFL and lip thickness were assessed for best fit; and agreement between digital and direct measurement methods was assessed. Reliability of digital measures was substantial within (kappa: 0.70-1.00) and between assessors (kappa: 0.64-0.89). Clinician and digital ratings showed moderate agreement (kappa: 0.47-0.58). Caucasian PFL norms and the African American Lip-Philtrum Guide 2 provided the best fit for this cohort. In an Aboriginal cohort with a high rate of FAS, assessment of facial dysmorphology using digital methods showed substantial inter- and intrarater reliability. Digital measurement of features has high reliability and until data are available from a larger population of Aboriginal children, the African American Lip-Philtrum Guide 2 and Caucasian (Strömland) PFL norms provide the best fit for Australian Aboriginal children.

  17. Intrarater Reliability of Muscle Strength and Hamstring to Quadriceps Strength Imbalance Ratios During Concentric, Isometric, and Eccentric Maximal Voluntary Contractions Using the Isoforce Dynamometer.

    PubMed

    Mau-Moeller, Anett; Gube, Martin; Felser, Sabine; Feldhege, Frank; Weippert, Matthias; Husmann, Florian; Tischer, Thomas; Bader, Rainer; Bruhn, Sven; Behrens, Martin

    2017-08-17

    To determine intrasession and intersession reliability of strength measurements and hamstrings to quadriceps strength imbalance ratios (H/Q ratios) using the new isoforce dynamometer. Repeated measures. Exercise science laboratory. Thirty healthy subjects (15 females, 15 males, 27.8 years). Coefficient of variation (CV) and intraclass correlation coefficients (ICC) were calculated for (1) strength parameters, that is peak torque, mean work, and mean power for concentric and eccentric maximal voluntary contractions; isometric maximal voluntary torque (IMVT); rate of torque development (RTD), and (2) H/Q ratios, that is conventional concentric, eccentric, and isometric H/Q ratios (Hcon/Qcon at 60 deg/s, 120 deg/s, and 180 deg/s, Hecc/Qecc at -60 deg/s and Hiso/Qiso) and functional eccentric antagonist to concentric agonist H/Q ratios (Hecc/Qcon and Hcon/Qecc). High reliability: CV <10%, ICC >0.90; moderate reliability: CV between 10% and 20%, ICC between 0.80 and 0.90; low reliability: CV >20%, ICC <0.80. (1) Strength parameters: (a) high intrasession reliability for concentric, eccentric, and isometric measurements, (b) moderate-to-high intersession reliability for concentric and eccentric measurements and IMVT, and (c) moderate-to-high intrasession reliability but low intersession reliability for RTD. (2) H/Q ratios: (a) moderate-to-high intrasession reliability for conventional ratios, (b) high intrasession reliability for functional ratios, (c) higher intersession reliability for Hcon/Qcon and Hiso/Qiso (moderate to high) than Hecc/Qecc (low to moderate), and (d) higher intersession reliability for conventional H/Q ratios (low to high) than functional H/Q ratios (low to moderate). The results have confirmed the reliability of strength parameters and the most frequently used H/Q ratios.

  18. Comparison of disease activity measures for anti-neutrophil cytoplasmic autoantibody (ANCA)-associated vasculitis.

    PubMed

    Merkel, P A; Cuthbertson, D D; Hellmich, B; Hoffman, G S; Jayne, D R W; Kallenberg, C G M; Krischer, J P; Luqmani, R; Mahr, A D; Matteson, E L; Specks, U; Stone, J H

    2009-01-01

    Currently, several different instruments are used to measure disease activity and extent in clinical trials of anti-neutrophil cytoplasmic autoantibody (ANCA)-associated vasculitis, leading to division among investigative groups and difficulty comparing study results. An exercise comparing six different vasculitis instruments was performed. A total of 10 experienced vasculitis investigators from 5 countries scored 20 cases in the literature of Wegener granulomatosis or microscopic polyangiitis using 6 disease assessment tools: the Birmingham Vasculitis Activity Score (BVAS), The BVAS for Wegener granulomatosis (BVAS/WG), BVAS 2003, a Physician Global Assessment (PGA), the Disease Extent Index (DEI) and the Five Factor Score (FFS). Five cases were rescored by all raters. Reliability of the measures was extremely high (intraclass correlations for the six measures all = 0.98). Within each instrument, there were no significant differences or outliers among the scores from the 10 investigators. Test/retest reliability was high for each measure: range = 0.77 to 0.95. The scores of the five acute activity measures correlated extremely well with one another. Currently available tools for measuring disease extent and activity in ANCA-associated vasculitis are highly correlated and reliable. These results provide investigators with confidence to compare different clinical trial data and helps form common ground as international research groups develop new, improved and universally accepted vasculitis disease assessment instruments.

  19. Reliable, Low-Cost, Low-Weight, Non-Hermetic Coating for MCM Applications

    NASA Technical Reports Server (NTRS)

    Jones, Eric W.; Licari, James J.

    2000-01-01

    Through an Air Force Research Laboratory sponsored STM program, reliable, low-cost, low-weight, non-hermetic coatings for multi-chip-module(MCK applications were developed. Using the combination of Sandia Laboratory ATC-01 test chips, AvanTeco's moisture sensor chips(MSC's), and silicon slices, we have shown that organic and organic/inorganic overcoatings are reliable and practical non-hermetic moisture and oxidation barriers. The use of the MSC and unpassivated ATC-01 test chips provided rapid test results and comparison of moisture barrier quality of the overcoatings. The organic coatings studied were Parylene and Cyclotene. The inorganic coatings were Al2O3 and SiO2. The choice of coating(s) is dependent on the environment that the device(s) will be exposed to. We have defined four(4) classes of environments: Class I(moderate temperature/moderate humidity). Class H(high temperature/moderate humidity). Class III(moderate temperature/high humidity). Class IV(high temperature/high humidity). By subjecting the components to adhesion, FTIR, temperature-humidity(TH), pressure cooker(PCT), and electrical tests, we have determined that it is possible to reduce failures 50-70% for organic/inorganic coated components compared to organic coated components. All materials and equipment used are readily available commercially or are standard in most semiconductor fabrication lines. It is estimated that production cost for the developed technology would range from $1-10/module, compared to $20-200 for hermetically sealed packages.

  20. Questionnaire for measuring organisational attributes in dental-care practices: psychometric properties and test-retest reliability.

    PubMed

    Goetz, Katja; Hasse, Philipp; Szecsenyi, Joachim; Campbell, Stephen M

    2016-04-01

    The consideration of organisational aspects, such as shared goals and clear communication, within the health care team is important to ensure good quality care. In primary health care, the instrument Survey of Organizational Attributes for Primary Care (SOAPC) is available to measure organisational attributes of care. However, there is no instrument available for dental care. The aim of the present study was to investigate psychometric properties and test-retest reliability of the version of SOAPC adapted for dental care, namely the Survey of Organizational Attributes in Dental Care (SOADC). The SOADC consists of 21 items in the following four subscales: communication; decision making; stress/chaos; and history of change. Convergent construct validity was measured using the job satisfaction scale. A total of 287 dental-care practices were asked to participate in the validation study. Psychometric properties and test-retest reliability were observed. A total of 43 dental-care practices responded to the survey. At baseline, 178 dental-care staff completed the questionnaire, and 4 weeks later 138 did so. Internal consistency, measured by Cronbach's alpha, was 0.718 or higher in the subscales. The test-retest reliability for each subscale and the overall SOADC score demonstrated good correlations over the 4-week test-retest interval, except for 'history of change'. A strong correlation with the aggregated job-satisfaction scale showed high convergent construct validity of SOADC. The consideration of organisational aspects from the perspective of dental-care teams is important for providing good quality of care. The SOADC is a reliable instrument with good psychometric properties and is suitable for the evaluation of organisational attributes in dental-care practices. © 2015 FDI World Dental Federation.

  1. Short communication: Genotyping of cows to speed up availability of genomic estimated breeding values for direct health traits in Austrian Fleckvieh (Simmental) cattle--genetic and economic aspects.

    PubMed

    Egger-Danner, C; Schwarzenbacher, H; Willam, A

    2014-07-01

    The aim of this study was to quantify the impact of genotyping cows with reliable phenotypes for direct health traits on annual monetary genetic gain (AMGG) and discounted profit. The calculations were based on a deterministic approach using ZPLAN software (University of Hohenheim, Stuttgart, Germany). It was assumed that increases in reliability of the total merit index (TMI) of 5, 15, and 25 percentage points were achieved through genotyping 5,000, 25,000, and 50,000 cows, respectively. Costs for phenotyping, genotyping, and genomic estimated breeding values vary between €150 and €20 per cow. The gain in genotyping cows for traits with medium to high heritability is more than for direct health traits with low heritability. The AMGG is increased by 1.5% if the reliability of TMI is 5 percentage points higher (i.e., 5,000 cows genotyped) and 6.53% higher AMGG can be expected when the reliability of TMI is increased by 25 percentage points (i.e., 50,000 cows genotyped). The discounted profit depends not only on the costs of genotyping but also on the population size. This study indicates that genotyping cows with reliable phenotypes is feasible to speed up the availability of genomic estimated breeding values for direct health traits. But, because of the huge amount of valid phenotypes and genotypes needed to establish an efficient genomic evaluation, it is likely that financial constraints will be the main limiting factor for implementation into breeding program such as Fleckvieh Austria. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Teletoxicology: Patient Assessment Using Wearable Audiovisual Streaming Technology.

    PubMed

    Skolnik, Aaron B; Chai, Peter R; Dameff, Christian; Gerkin, Richard; Monas, Jessica; Padilla-Jones, Angela; Curry, Steven

    2016-12-01

    Audiovisual streaming technologies allow detailed remote patient assessment and have been suggested to change management and enhance triage. The advent of wearable, head-mounted devices (HMDs) permits advanced teletoxicology at a relatively low cost. A previously published pilot study supports the feasibility of using the HMD Google Glass® (Google Inc.; Mountain View, CA) for teletoxicology consultation. This study examines the reliability, accuracy, and precision of the poisoned patient assessment when performed remotely via Google Glass®. A prospective observational cohort study was performed on 50 patients admitted to a tertiary care center inpatient toxicology service. Toxicology fellows wore Google Glass® and transmitted secure, real-time video and audio of the initial physical examination to a remote investigator not involved in the subject's care. High-resolution still photos of electrocardiograms (ECGs) were transmitted to the remote investigator. On-site and remote investigators recorded physical examination findings and ECG interpretation. Both investigators completed a brief survey about the acceptability and reliability of the streaming technology for each encounter. Kappa scores and simple agreement were calculated for each examination finding and electrocardiogram parameter. Reliability scores and reliability difference were calculated and compared for each encounter. Data were available for analysis of 17 categories of examination and ECG findings. Simple agreement between on-site and remote investigators ranged from 68 to 100 % (median = 94 %, IQR = 10.5). Kappa scores could be calculated for 11/17 parameters and demonstrated slight to fair agreement for two parameters and moderate to almost perfect agreement for nine parameters (median = 0.653; substantial agreement). The lowest Kappa scores were for pupil size and response to light. On a 100-mm visual analog scale (VAS), mean comfort level was 93 and mean reliability rating was 89 for on-site investigators. For remote users, the mean comfort and reliability ratings were 99 and 86, respectively. The average difference in reliability scores between on-site and remote investigators was 2.6, with the difference increasing as reliability scores decreased. Remote evaluation of poisoned patients via Google Glass® is possible with a high degree of agreement on examination findings and ECG interpretation. Evaluation of pupil size and response to light is limited, likely by the quality of streaming video. Users of Google Glass® for teletoxicology reported high levels of comfort with the technology and found it reliable, though as reported reliability decreased, remote users were most affected. Further study should compare patient-centered outcomes when using HMDs for consultation to those resulting from telephone consultation.

  3. Mathematical modeling and fuzzy availability analysis for serial processes in the crystallization system of a sugar plant

    NASA Astrophysics Data System (ADS)

    Aggarwal, Anil Kr.; Kumar, Sanjeev; Singh, Vikram

    2017-03-01

    The binary states, i.e., success or failed state assumptions used in conventional reliability are inappropriate for reliability analysis of complex industrial systems due to lack of sufficient probabilistic information. For large complex systems, the uncertainty of each individual parameter enhances the uncertainty of the system reliability. In this paper, the concept of fuzzy reliability has been used for reliability analysis of the system, and the effect of coverage factor, failure and repair rates of subsystems on fuzzy availability for fault-tolerant crystallization system of sugar plant is analyzed. Mathematical modeling of the system is carried out using the mnemonic rule to derive Chapman-Kolmogorov differential equations. These governing differential equations are solved with Runge-Kutta fourth-order method.

  4. HTGR plant availability and reliability evaluations. Volume I. Summary of evaluations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cadwallader, G.J.; Hannaman, G.W.; Jacobsen, F.K.

    1976-12-01

    The report (1) describes a reliability assessment methodology for systematically locating and correcting areas which may contribute to unavailability of new and uniquely designed components and systems, (2) illustrates the methodology by applying it to such components in a high-temperature gas-cooled reactor (Public Service Company of Colorado's Fort St. Vrain 330-MW(e) HTGR), and (3) compares the results of the assessment with actual experience. The methodology can be applied to any component or system; however, it is particularly valuable for assessments of components or systems which provide essential functions, or the failure or mishandling of which could result in relatively largemore » economic losses.« less

  5. Numerical aerodynamic simulation facility. Preliminary study extension

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The production of an optimized design of key elements of the candidate facility was the primary objective of this report. This was accomplished by effort in the following tasks: (1) to further develop, optimize and describe the function description of the custom hardware; (2) to delineate trade off areas between performance, reliability, availability, serviceability, and programmability; (3) to develop metrics and models for validation of the candidate systems performance; (4) to conduct a functional simulation of the system design; (5) to perform a reliability analysis of the system design; and (6) to develop the software specifications to include a user level high level programming language, a correspondence between the programming language and instruction set and outline the operation system requirements.

  6. Development of a Nondestructive Evaluation Technique for Degraded Thermal Barrier Coatings Using Microwave

    NASA Astrophysics Data System (ADS)

    Sayar, M.; Ogawa, K.; Shoji, T.

    2008-02-01

    Thermal barrier coatings have been widely used in gas turbine engines in order to protect substrate metal alloy against high temperature and to enhance turbine efficiency. Currently, there are no reliable nondestructive techniques available to monitor TBC integrity over lifetime of the coating. Hence, to detect top coating (TC) and TGO thicknesses, a microwave nondestructive technique that utilizes a rectangular waveguide was developed. The phase of the reflection coefficient at the interface of TC and waveguide varies for different TGO and TC thicknesses. Therefore, measuring the phase of the reflection coefficient enables us to accurately calculate these thicknesses. Finally, a theoretical analysis was used to evaluate the reliability of the experimental results.

  7. Screening for depression in clinical practice: reliability and validity of a five-item subset of the CES-Depression.

    PubMed

    Bohannon, Richard W; Maljanian, Rose; Goethe, John

    2003-12-01

    Individuals with chronic disease are not screened routinely for depression. Availability of an abbreviated test with demonstrated reliability and validity might encourage screening so we explored the reliability and validity of a 5-item subset of the 20-item Center for Epidemiological Studies Depression Scale among inner-city outpatients with chronic asthma or diabetes. Most patients were female (73.1%) and Hispanic (61.8%). Acceptable reliability was shown by Cronbach alpha (.76) for the subset of 5 items. Validity was supported by the high correlation of .91 between patients' scores on the 5-item subset and the full 20 items. The 5 items reflected a single factor (eigenvalue = 2.66). Receiver operating characteristic curve analysis identified cut-points for the 5 items that were sensitive (> .84) and specific (> or = .80) in identifying patients classified as depressed by full 20 items. The reduced patient and clinician burden of the subset of 5 items, as well as its desirable psychometric properties, support broader application of this subset as a screening tool for depression.

  8. High Reliability and the Evaluation of ATC System Configuration by Communizing Resources

    NASA Astrophysics Data System (ADS)

    Yamamoto, Masanori

    Automatic Train Control (ATC) in the railway signalling system is required high safety, high availability, reduction of unit, energy saving and cost reduction. This paper described the resources communization redundancy of the ATC system that shared the redundant units in preparation for common use units in order to accommodate with this issue by keeping safety and availability in the same level of conventional ATC. It was evaluated on N+2 redundant system which established 2 spares for the common use system N piece in transmission division. It was done the safety evaluation of the N+2 redundant system by way of hazard analysis of FTA method and safety issue was confirmed by FMEA. The new redundant system concludes that 19% of downsizing and 36% of the energy saving are surely possible.

  9. Reliability Considerations for the Operation of Large Accelerator User Facilities

    DOE PAGES

    Willeke, F. J.

    2016-01-29

    The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.

  10. 76 FR 34086 - Mandatory Guidelines for Federal Workplace Drug Testing Programs; Request for Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-10

    ... standards that require the use of the best available technology for ensuring the full reliability and... available technology for ensuring the full reliability and accuracy of urine drug tests, while reflecting..., cutoffs, specimen validity, collection, collection devices, and testing. II. Solicitation of Comments: As...

  11. Capacity and reliability analyses with applications to power quality

    NASA Astrophysics Data System (ADS)

    Azam, Mohammad; Tu, Fang; Shlapak, Yuri; Kirubarajan, Thiagalingam; Pattipati, Krishna R.; Karanam, Rajaiah

    2001-07-01

    The deregulation of energy markets, the ongoing advances in communication networks, the proliferation of intelligent metering and protective power devices, and the standardization of software/hardware interfaces are creating a dramatic shift in the way facilities acquire and utilize information about their power usage. The currently available power management systems gather a vast amount of information in the form of power usage, voltages, currents, and their time-dependent waveforms from a variety of devices (for example, circuit breakers, transformers, energy and power quality meters, protective relays, programmable logic controllers, motor control centers). What is lacking is an information processing and decision support infrastructure to harness this voluminous information into usable operational and management knowledge to handle the health of their equipment and power quality, minimize downtime and outages, and to optimize operations to improve productivity. This paper considers the problem of evaluating the capacity and reliability analyses of power systems with very high availability requirements (e.g., systems providing energy to data centers and communication networks with desired availability of up to 0.9999999). The real-time capacity and margin analysis helps operators to plan for additional loads and to schedule repair/replacement activities. The reliability analysis, based on computationally efficient sum of disjoint products, enables analysts to decide the optimum levels of redundancy, aids operators in prioritizing the maintenance options for a given budget and monitoring the system for capacity margin. The resulting analytical and software tool is demonstrated on a sample data center.

  12. Designing for Reliability and Robustness

    NASA Technical Reports Server (NTRS)

    Svetlik, Randall G.; Moore, Cherice; Williams, Antony

    2017-01-01

    Long duration spaceflight has a negative effect on the human body, and exercise countermeasures are used on-board the International Space Station (ISS) to minimize bone and muscle loss, combatting these effects. Given the importance of these hardware systems to the health of the crew, this equipment must continue to be readily available. Designing spaceflight exercise hardware to meet high reliability and availability standards has proven to be challenging throughout the time the crewmembers have been living on ISS beginning in 2000. Furthermore, restoring operational capability after a failure is clearly time-critical, but can be problematic given the challenges of troubleshooting the problem from 220 miles away. Several best-practices have been leveraged in seeking to maximize availability of these exercise systems, including designing for robustness, implementing diagnostic instrumentation, relying on user feedback, and providing ample maintenance and sparing. These factors have enhanced the reliability of hardware systems, and therefore have contributed to keeping the crewmembers healthy upon return to Earth. This paper will review the failure history for three spaceflight exercise countermeasure systems identifying lessons learned that can help improve future systems. Specifically, the Treadmill with Vibration Isolation and Stabilization System (TVIS), Cycle Ergometer with Vibration Isolation and Stabilization System (CEVIS), and the Advanced Resistive Exercise Device (ARED) will be reviewed, analyzed, and conclusions identified so as to provide guidance for improving future exercise hardware designs. These lessons learned, paired with thorough testing, offer a path towards reduced system down-time.

  13. Development of an intensive care unit resource assessment survey for the care of critically ill patients in resource-limited settings.

    PubMed

    Leligdowicz, Aleksandra; Bhagwanjee, Satish; Diaz, Janet V; Xiong, Wei; Marshall, John C; Fowler, Robert A; Adhikari, Neill Kj

    2017-04-01

    Capacity to provide critical care in resource-limited settings is poorly understood because of lack of data about resources available to manage critically ill patients. Our objective was to develop a survey to address this issue. We developed and piloted a cross-sectional self-administered survey in 9 resource-limited countries. The survey consisted of 8 domains; specific items within domains were modified from previously developed survey tools. We distributed the survey by e-mail to a convenience sample of health care providers responsible for providing care to critically ill patients. We assessed clinical sensibility and test-retest reliability. Nine of 15 health care providers responded to the survey on 2 separate occasions, separated by 2 to 4 weeks. Clinical sensibility was high (3.9-4.9/5 on assessment tool). Test-retest reliability for questions related to resource availability was acceptable (intraclass correlation coefficient, 0.94; 95% confidence interval, 0.75-0.99; mean (SD) of weighted κ values = 0.67 [0.19]). The mean (SD) time for survey completion survey was 21 (16) minutes. A reliable cross-sectional survey of available resources to manage critically ill patients can be feasibly administered to health care providers in resource-limited settings. The survey will inform future research focusing on access to critical care where it is poorly described but urgently needed. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Reliability of EEG Measures of Interaction: A Paradigm Shift Is Needed to Fight the Reproducibility Crisis

    PubMed Central

    Höller, Yvonne; Uhl, Andreas; Bathke, Arne; Thomschewski, Aljoscha; Butz, Kevin; Nardone, Raffaele; Fell, Jürgen; Trinka, Eugen

    2017-01-01

    Measures of interaction (connectivity) of the EEG are at the forefront of current neuroscientific research. Unfortunately, test-retest reliability can be very low, depending on the measure and its estimation, the EEG-frequency of interest, the length of the signal, and the population under investigation. In addition, artifacts can hamper the continuity of the EEG signal, and in some clinical situations it is impractical to exclude artifacts. We aimed to examine factors that moderate test-retest reliability of measures of interaction. The study involved 40 patients with a range of neurological diseases and memory impairments (age median: 60; range 21–76; 40% female; 22 mild cognitive impairment, 5 subjective cognitive complaints, 13 temporal lobe epilepsy), and 20 healthy controls (age median: 61.5; range 23–74; 70% female). We calculated 14 measures of interaction based on the multivariate autoregressive model from two EEG-recordings separated by 2 weeks. We characterized test-retest reliability by correlating the measures between the two EEG-recordings for variations of data length, data discontinuity, artifact exclusion, model order, and frequency over all combinations of channels and all frequencies, individually for each subject, yielding a correlation coefficient for each participant. Excluding artifacts had strong effects on reliability of some measures, such as classical, real valued coherence (~0.1 before, ~0.9 after artifact exclusion). Full frequency directed transfer function was highly reliable and robust against artifacts. Variation of data length decreased reliability in relation to poor adjustment of model order and signal length. Variation of discontinuity had no effect, but reliabilities were different between model orders, frequency ranges, and patient groups depending on the measure. Pathology did not interact with variation of signal length or discontinuity. Our results emphasize the importance of documenting reliability, which may vary considerably between measures of interaction. We recommend careful selection of measures of interaction in accordance with the properties of the data. When only short data segments are available and when the signal length varies strongly across subjects after exclusion of artifacts, reliability becomes an issue. Finally, measures which show high reliability irrespective of the presence of artifacts could be extremely useful in clinical situations when exclusion of artifacts is impractical. PMID:28912704

  15. Interventions for Age-Related Macular Degeneration: Are Practice Guidelines Based on Systematic Reviews?

    PubMed

    Lindsley, Kristina; Li, Tianjing; Ssemanda, Elizabeth; Virgili, Gianni; Dickersin, Kay

    2016-04-01

    Are existing systematic reviews of interventions for age-related macular degeneration incorporated into clinical practice guidelines? High-quality systematic reviews should be used to underpin evidence-based clinical practice guidelines and clinical care. We examined the reliability of systematic reviews of interventions for age-related macular degeneration (AMD) and described the main findings of reliable reviews in relation to clinical practice guidelines. Eligible publications were systematic reviews of the effectiveness of treatment interventions for AMD. We searched a database of systematic reviews in eyes and vision without language or date restrictions; the database was up to date as of May 6, 2014. Two authors independently screened records for eligibility and abstracted and assessed the characteristics and methods of each review. We classified reviews as reliable when they reported eligibility criteria, comprehensive searches, methodologic quality of included studies, appropriate statistical methods for meta-analysis, and conclusions based on results. We mapped treatment recommendations from the American Academy of Ophthalmology (AAO) Preferred Practice Patterns (PPPs) for AMD to systematic reviews and citations of reliable systematic reviews to support each treatment recommendation. Of 1570 systematic reviews in our database, 47 met inclusion criteria; most targeted neovascular AMD and investigated anti-vascular endothelial growth factor (VEGF) interventions, dietary supplements, or photodynamic therapy. We classified 33 (70%) reviews as reliable. The quality of reporting varied, with criteria for reliable reporting met more often by Cochrane reviews and reviews whose authors disclosed conflicts of interest. Anti-VEGF agents and photodynamic therapy were the only interventions identified as effective by reliable reviews. Of 35 treatment recommendations extracted from the PPPs, 15 could have been supported with reliable systematic reviews; however, only 1 recommendation cited a reliable intervention systematic review. No reliable systematic review was identified for 20 treatment recommendations, highlighting areas of evidence gaps. For AMD, reliable systematic reviews exist for many treatment recommendations in the AAO PPPs and should be cited to support these recommendations. We also identified areas where no high-level evidence exists. Mapping clinical practice guidelines to existing systematic reviews is one way to highlight areas where evidence generation or evidence synthesis is either available or needed. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. confFuse: High-Confidence Fusion Gene Detection across Tumor Entities.

    PubMed

    Huang, Zhiqin; Jones, David T W; Wu, Yonghe; Lichter, Peter; Zapatka, Marc

    2017-01-01

    Background: Fusion genes play an important role in the tumorigenesis of many cancers. Next-generation sequencing (NGS) technologies have been successfully applied in fusion gene detection for the last several years, and a number of NGS-based tools have been developed for identifying fusion genes during this period. Most fusion gene detection tools based on RNA-seq data report a large number of candidates (mostly false positives), making it hard to prioritize candidates for experimental validation and further analysis. Selection of reliable fusion genes for downstream analysis becomes very important in cancer research. We therefore developed confFuse, a scoring algorithm to reliably select high-confidence fusion genes which are likely to be biologically relevant. Results: confFuse takes multiple parameters into account in order to assign each fusion candidate a confidence score, of which score ≥8 indicates high-confidence fusion gene predictions. These parameters were manually curated based on our experience and on certain structural motifs of fusion genes. Compared with alternative tools, based on 96 published RNA-seq samples from different tumor entities, our method can significantly reduce the number of fusion candidates (301 high-confidence from 8,083 total predicted fusion genes) and keep high detection accuracy (recovery rate 85.7%). Validation of 18 novel, high-confidence fusions detected in three breast tumor samples resulted in a 100% validation rate. Conclusions: confFuse is a novel downstream filtering method that allows selection of highly reliable fusion gene candidates for further downstream analysis and experimental validations. confFuse is available at https://github.com/Zhiqin-HUANG/confFuse.

  17. High reliability and implications for nursing leaders.

    PubMed

    Riley, William

    2009-03-01

    To review high reliability theory and discuss its implications for the nursing leader. A high reliability organization (HRO) is considered that which has measurable near perfect performance for quality and safety. The author has reviewed the literature, discussed research findings that contribute to improving reliability in health care organizations, and makes five recommendations for how nursing leaders can create high reliability organizations. Health care is not a safe industry and unintended patient harm occurs at epidemic levels. Health care can learn from high reliability theory and practice developed in other high-risk industries. Viewed by HRO standards, unintended patient injury in health care is excessively high and quality is distressingly low. HRO theory and practice can be successfully applied in health care using advanced interdisciplinary teamwork training and deliberate process design techniques. Nursing has a primary leadership function for ensuring patient safety and achieving high quality in health care organizations. Learning HRO theory and methods for achieving high reliability is a foremost opportunity for nursing leaders.

  18. Psychometric properties of the SCOFF questionnaire (Chinese version) for screening eating disorders in Hong Kong secondary school students: a cross-sectional study.

    PubMed

    Leung, Sau Fong; Lee, Ka Li; Lee, Sze Man; Leung, Sik Chi; Hung, Wing Sze; Lee, Wai Leng; Leung, Yuen Yee; Li, Man Wai; Tse, Tak Kin; Wong, Hoi Kei; Wong, Yuen Ni

    2009-02-01

    Eating disorders are affecting an increasing number of high school students in Western and Asian countries. The availability of an effective screening tool is crucial for early detection and prompt intervention. The objective of this study was to examine the validity and reliability of the SCOFF questionnaire for screening eating disorders in Hong Kong high school students. This study adopted a cross-sectional design to examine the psychometric properties of the SCOFF questionnaire. A panel of 7 experts and 936 students of a high school participated in the study. The SCOFF questionnaire was translated into Chinese and back-translated into English to ensure the linguistic equivalence. A panel of 7 experts involved in the content validation of the SCOFF questionnaire. The Eating Disorder Examination-Questionnaire (EDE-Q) was used as the "reference standard" to assess its concurrent validity in 936 students of a high school. Its reliability was examined by internal consistency and the test-retest method at a 2-week interval and with 38 students. The SCOFF questionnaire achieved an agreement of 86-100% among the experts for the content relevance. Of 812 students (86.8%) who responded to this study, their SCOFF scores correlated significantly with their global scores on the EDE-Q (r=0.5, P<0.01). Students identified as potentially having eating disorders had significantly higher scores in the EDE-Q than those not identified as such by SCOFF. The SCOFF questionnaire demonstrated moderate test-retest reliability (ICC=0.66) and an acceptable internal consistency reliability (Cronbach's alpha=0.44-0.57) in comparing with previous studies. The SCOFF questionnaire has acceptable psychometric properties in the Chinese culture. It will be useful for detecting potential eating disorders and assisting health promotion activity.

  19. Evaluating the use of in-store measures in retail food stores and restaurants in Brazil.

    PubMed

    Duran, Ana Clara; Lock, Karen; Latorre, Maria do Rosario D O; Jaime, Patricia Constante

    2015-01-01

    To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context. This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool's abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants. Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods. The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts.

  20. Evaluating the use of in-store measures in retail food stores and restaurants in Brazil

    PubMed Central

    Duran, Ana Clara; Lock, Karen; Latorre, Maria do Rosario D O; Jaime, Patricia Constante

    2015-01-01

    ABSTRACT OBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context. METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants. RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods. CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these contexts. PMID:26538101

  1. Systematic review found AMSTAR, but not R(evised)-AMSTAR, to have good measurement properties.

    PubMed

    Pieper, Dawid; Buechter, Roland Brian; Li, Lun; Prediger, Barbara; Eikermann, Michaela

    2015-05-01

    To summarize all available evidence on measurement properties in terms of reliability, validity, and feasibility of the Assessment of Multiple Systematic Reviews (AMSTAR) tool, including R(evised)-AMSTAR. MEDLINE, EMBASE, Psycinfo, and CINAHL were searched for studies containing information on measurement properties of the tools in October 2013. We extracted data on study characteristics and measurement properties. These data were analyzed following measurement criteria. We included 13 studies, four of them were labeled as validation studies. Nine articles dealt with AMSTAR, two articles dealt with R-AMSTAR, and one article dealt with both instruments. In terms of interrater reliability, most items showed a substantial agreement (>0.6). The median intraclass correlation coefficient (ICC) for the overall score of AMSTAR was 0.83 (range 0.60-0.98), indicating a high agreement. In terms of validity, ICCs were very high with all but one ICC lower than 0.8 when the AMSTAR score was compared with scores from other tools. Scoring AMSTAR takes between 10 and 20 minutes. AMSTAR seems to be reliable and valid. Further investigations for systematic reviews of other study designs than randomized controlled trials are needed. R-AMSTAR should be further investigated as evidence for its use is limited and its measurement properties have not been studied sufficiently. In general, test-retest reliability should be investigated in future studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Measuring the contribution of art therapy in multidisciplinary treatment of personality disorders: The construction of the Self‐expression and Emotion Regulation in Art Therapy Scale (SERATS)

    PubMed Central

    van Hooren, Susan; van der Veld, William M.; Hutschemaekers, Giel

    2017-01-01

    Abstract Despite the use of art therapy in clinical practice, its appreciation and reported beneficial results, no instruments are available to measure specific effects of art therapy among patients with personality disorders cluster B/C in multidisciplinary treatment. In the present study, we described the development and psychometric evaluation of the Self‐expression and Emotion Regulation in Art Therapy Scale (SERATS). Structural validity (exploratory and confirmatory factor analysis), reliability, construct validity and sensitivity to change were examined using two independent databases (n = 335; n = 34) of patients diagnosed with personality disorders cluster B/C. This resulted in a nine‐item effect scale with a single factor with a high internal reliability and high test–retest reliability; it demonstrated discriminant validity and sensitivity to change. In conclusion, the SERATS is brief and content‐valid and offers objective and reliable information on self‐expression and emotion regulation in art therapy among patients with personality disorders cluster B/C. Although more research on construct validity is needed, the SERATS is a promising tool to be applied as an effect scale and as a monitoring tool during art therapy treatment. © 2017 The Authors Personality and Mental Health Published by John Wiley & Sons Ltd PMID:28730717

  3. High Reliability Prototype Quadrupole for the Next Linear Collider

    NASA Astrophysics Data System (ADS)

    Spencer, C. M.

    2001-01-01

    The Next Linear Collider (NLC) will require over 5600 magnets, each of which must be highly reliable and/or quickly repairable in order that the NLC reach its 85/ overall availability goal. A multidiscipline engineering team was assembled at SLAC to develop a more reliable electromagnet design than historically had been achieved at SLAC. This team carried out a Failure Mode and Effects Analysis (FMEA) on a standard SLAC quadrupole magnet system. They overcame a number of longstanding design prejudices, producing 10 major design changes. This paper describes how a prototype magnet was constructed and the extensive testing carried out on it to prove full functionality with an improvement in reliability. The magnet's fabrication cost will be compared to the cost of a magnet with the same requirements made in the historic SLAC way. The NLC will use over 1600 of these 12.7 mm bore quadrupoles with a range of integrated strengths from 0.6 to 132 Tesla, a maximum gradient of 135 Tesla per meter, an adjustment range of 0 to -20/ and core lengths from 324 mm to 972 mm. The magnetic center must remain stable to within 1 micron during the 20/ adjustment. A magnetic measurement set-up has been developed that can measure sub-micron shifts of a magnetic center. The prototype satisfied the center shift requirement over the full range of integrated strengths.

  4. 7 CFR 760.405 - Application process.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... death documentation is not available, the participant may provide reliable records, in conjunction with verifiable beginning and ending inventory records, as proof of death. Reliable records may include..., pictures, and other similar reliable documents as determined by FSA. (f) Certification of livestock deaths...

  5. A GIS-based assessment of the suitability of SCIAMACHY satellite sensor measurements for estimating reliable CO concentrations in a low-latitude climate.

    PubMed

    Fagbeja, Mofoluso A; Hill, Jennifer L; Chatterton, Tim J; Longhurst, James W S

    2015-02-01

    An assessment of the reliability of the Scanning Imaging Absorption Spectrometer for Atmospheric Cartography (SCIAMACHY) satellite sensor measurements to interpolate tropospheric concentrations of carbon monoxide considering the low-latitude climate of the Niger Delta region in Nigeria was conducted. Monthly SCIAMACHY carbon monoxide (CO) column measurements from January 2,003 to December 2005 were interpolated using ordinary kriging technique. The spatio-temporal variations observed in the reliability were based on proximity to the Atlantic Ocean, seasonal variations in the intensities of rainfall and relative humidity, the presence of dust particles from the Sahara desert, industrialization in Southwest Nigeria and biomass burning during the dry season in Northern Nigeria. Spatial reliabilities of 74 and 42 % are observed for the inland and coastal areas, respectively. Temporally, average reliability of 61 and 55 % occur during the dry and wet seasons, respectively. Reliability in the inland and coastal areas was 72 and 38 % during the wet season, and 75 and 46 % during the dry season, respectively. Based on the results, the WFM-DOAS SCIAMACHY CO data product used for this study is therefore relevant in the assessment of CO concentrations in developing countries within the low latitudes that could not afford monitoring infrastructure due to the required high costs. Although the SCIAMACHY sensor is no longer available, it provided cost-effective, reliable and accessible data that could support air quality assessment in developing countries.

  6. Evaluation of tools used to measure calcium and/or dairy consumption in children and adolescents.

    PubMed

    Magarey, Anthea; Yaxley, Alison; Markow, Kylie; Baulderstone, Lauren; Miller, Michelle

    2014-08-01

    To identify and critique tools that assess Ca and/or dairy intake in children to ascertain the most accurate and reliable tools available. A systematic review of the literature was conducted using defined inclusion and exclusion criteria. Articles were included on the basis that they reported on a tool measuring Ca and/or dairy intake in children in Western countries and reported on originally developed tools or tested the validity or reliability of existing tools. Defined criteria for reporting reliability and validity properties were applied. Studies in Western countries. Children. Eighteen papers reporting on two tools that assessed dairy intake, ten that assessed Ca intake and five that assessed both dairy and Ca were identified. An examination of tool testing revealed high reliance on lower-order tests such as correlation and failure to differentiate between statistical and clinically meaningful significance. Only half of the tools were tested for reliability and results indicated that only one Ca tool and one dairy tool were reliable. Validation studies showed acceptable levels of agreement (<100 mg difference) and/or sensitivity (62-83 %) and specificity (55-77 %) in three Ca tools. With reference to the testing methodology and results, no tools were considered both valid and reliable for the assessment of dairy intake and only one tool proved valid and reliable for the assessment of Ca intake. These results clearly indicate the need for development and rigorous testing of tools to assess Ca and/or dairy intake in children and adolescents.

  7. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    PubMed

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  8. Reliability of a store observation tool in measuring availability of alcohol and selected foods.

    PubMed

    Cohen, Deborah A; Schoeff, Diane; Farley, Thomas A; Bluthenthal, Ricky; Scribner, Richard; Overton, Adrian

    2007-11-01

    Alcohol and food items can compromise or contribute to health, depending on the quantity and frequency with which they are consumed. How much people consume may be influenced by product availability and promotion in local retail stores. We developed and tested an observational tool to objectively measure in-store availability and promotion of alcoholic beverages and selected food items that have an impact on health. Trained observers visited 51 alcohol outlets in Los Angeles and southeastern Louisiana. Using a standardized instrument, two independent observations were conducted documenting the type of outlet, the availability and shelf space for alcoholic beverages and selected food items, the purchase price of standard brands, the placement of beer and malt liquor, and the amount of in-store alcohol advertising. Reliability of the instrument was excellent for measures of item availability, shelf space, and placement of malt liquor. Reliability was lower for alcohol advertising, beer placement, and items that measured the "least price" of apples and oranges. The average kappa was 0.87 for categorical items and the average intraclass correlation coefficient was 0.83 for continuous items. Overall, systematic observation of the availability and promotion of alcoholic beverages and food items was feasible, acceptable, and reliable. Measurement tools such as the one we evaluated should be useful in studies of the impact of availability of food and beverages on consumption and on health outcomes.

  9. Intra- and inter-observer reliability of quantitative analysis of the infra-patellar fat pad and comparison between fat- and non-fat-suppressed imaging--Data from the osteoarthritis initiative.

    PubMed

    Steidle-Kloc, E; Wirth, W; Ruhdorfer, A; Dannhauer, T; Eckstein, F

    2016-03-01

    The infra-patellar fat pad (IPFP), as intra-articular adipose tissue represents a potential source of pro-inflammatory cytokines and its size has been suggested to be associated with osteoarthritis (OA) of the knee. This study examines inter- and intra-observer reliability of fat-suppressed (fs) and non-fat-suppressed (nfs) MR imaging for determination of IPFP morphological measurements as novel biomarkers. The IPFP of nine right knees of healthy Osteoarthritis Initiative participants was segmented by five readers, using fs and nfs baseline sagittal MRIs. The intra-observer reliability was determined from baseline and 1-year follow-up images. All segmentations were quality controlled (QC) by an expert reader. Reliability was expressed as root mean square coefficient of variation (RMS CV%). After QC, the inter-observer reliability for fs (nfs) imaging was 2.0% (1.1%) for IPFP volume, 2.1%/2.5% (1.6%/1.8%) for anterior/posterior surface areas, 1.8% (1.8%) for depth, and 2.1% (2.4%) for maximum sagittal area. The intra-observer reliability was 3.1% (5.0%) for volume, 2.3%/2.8% (2.5%/2.9%) for anterior/posterior surfaces, 1.9% (3.5%) for depth, and 3.3% (4.5%) for maximum sagittal area. IPFP volume from nfs images was systematically greater (+7.3%) than from fs images, but highly correlated (r=0.98). The results suggest that quantitative measurements of IPFP morphology can be performed with satisfactory reliability when expert QC is implemented. The IPFP is more clearly depicted in nfs images, and there is a small systematic off-set versus analysis from fs images. However, the high linear relationship between fs and nfs imaging suggests that fs images can be used to analyze IPFP morphology, when nfs images are not available. Copyright © 2015 Elsevier GmbH. All rights reserved.

  10. Assessment of the reliability of protein-protein interactions and protein function prediction.

    PubMed

    Deng, Minghua; Sun, Fengzhu; Chen, Ting

    2003-01-01

    As more and more high-throughput protein-protein interaction data are collected, the task of estimating the reliability of different data sets becomes increasingly important. In this paper, we present our study of two groups of protein-protein interaction data, the physical interaction data and the protein complex data, and estimate the reliability of these data sets using three different measurements: (1) the distribution of gene expression correlation coefficients, (2) the reliability based on gene expression correlation coefficients, and (3) the accuracy of protein function predictions. We develop a maximum likelihood method to estimate the reliability of protein interaction data sets according to the distribution of correlation coefficients of gene expression profiles of putative interacting protein pairs. The results of the three measurements are consistent with each other. The MIPS protein complex data have the highest mean gene expression correlation coefficients (0.256) and the highest accuracy in predicting protein functions (70% sensitivity and specificity), while Ito's Yeast two-hybrid data have the lowest mean (0.041) and the lowest accuracy (15% sensitivity and specificity). Uetz's data are more reliable than Ito's data in all three measurements, and the TAP protein complex data are more reliable than the HMS-PCI data in all three measurements as well. The complex data sets generally perform better in function predictions than do the physical interaction data sets. Proteins in complexes are shown to be more highly correlated in gene expression. The results confirm that the components of a protein complex can be assigned to functions that the complex carries out within a cell. There are three interaction data sets different from the above two groups: the genetic interaction data, the in-silico data and the syn-express data. Their capability of predicting protein functions generally falls between that of the Y2H data and that of the MIPS protein complex data. The supplementary information is available at the following Web site: http://www-hto.usc.edu/-msms/AssessInteraction/.

  11. Intra- and inter-observer reliability of quantitative analysis of the infra-patellar fat pad and comparison between fat- and non-fat-suppressed imaging—Data from the osteoarthritis initiative

    PubMed Central

    Steidle-Kloc, E.; Wirth, W.; Ruhdorfer, A.; Dannhauer, T.; Eckstein, F.

    2015-01-01

    The infra-patellar fat pad (IPFP), as intra-articular adipose tissue represents a potential source of pro-inflammatory cytokines and its size has been suggested to be associated with osteoarthritis (OA) of the knee. This study examines inter- and intra-observer reliability of fat-suppressed (fs) and non-fat-suppressed (nfs) MR imaging for determination of IPFP morphological measurements as novel biomarkers. The IPFP of nine right knees of healthy Osteoarthritis Initiative participants was segmented by five readers, using fs and nfs baseline sagittal MRIs. The intra-observer reliability was determined from baseline and 1-year follow-up images. All segmentations were quality controlled (QC) by an expert reader. Reliability was expressed as root mean square coefficient of variation (RMS CV%). After QC, the inter-observer reliability for fs (nfs) imaging was 2.0% (1.1%) for IPFP volume, 2.1%/2.5% (1.6%/1.8%) for anterior/posterior surface areas, 1.8% (1.8%) for depth, and 2.1% (2.4%) for maximum sagittal area. The intra-observer reliability was 3.1% (5.0%) for volume, 2.3%/2.8% (2.5%/2.9%) for anterior/posterior surfaces, 1.9% (3.5%) for depth, and 3.3% (4.5%) for maximum sagittal area. IPFP volume from nfs images was systematically greater (+7.3%) than from fs images, but highly correlated (r = 0.98). The results suggest that quantitative measurements of IPFP morphology can be performed with satisfactory reliability when expert QC is implemented. The IPFP is more clearly depicted in nfs images, and there is a small systematic off-set versus analysis from fs images. However, the high linear relationship between fs and nfs imaging suggests that fs images can be used to analyze IPFP morphology, when nfs images are not available. PMID:26569532

  12. Translation, cultural adaption, and test-retest reliability of Chinese versions of the Edinburgh Handedness Inventory and Waterloo Footedness Questionnaire.

    PubMed

    Yang, Nan; Waddington, Gordon; Adams, Roger; Han, Jia

    2018-05-01

    Quantitative assessments of handedness and footedness are often required in studies of human cognition and behaviour, yet no reliable Chinese versions of commonly used handedness and footedness questionnaires are available. Accordingly, the objective of the present study was to translate the Edinburgh Handedness Inventory (EHI) and the Waterloo Footedness Questionnaire-Revised (WFQ-R) into Mandarin Chinese and to evaluate the reliability and validity of these translated versions in healthy Chinese people. In the first stage of the study, Chinese versions of the EHI and WFQ-R were produced from a process of translation, back translation and examination, with necessary cultural adaptations. The second stage involved determining the reliability and validity of the translated EHI and WFQ-R for the Chinese population. One hundred and ten Chinese participants were tested online, and the results showed that the Cronbach's alpha coefficient of internal consistency was 0.877 for the translated EHI and 0.855 for the translated WFQ-R. Another 170 Chinese participants were tested and re-tested after a 30-day interval. The intra-class correlation coefficients showed high reliability, 0.898 for the translated EHI and 0.869 for the translated WFQ-R. This preliminary validation study found the translated versions to be reliable and valid tools for assessing handedness and footedness in this population.

  13. Reliability of an Automated High-Resolution Manometry Analysis Program across Expert Users, Novice Users, and Speech-Language Pathologists

    ERIC Educational Resources Information Center

    Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.

    2014-01-01

    Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…

  14. Understanding the importance of an energy crisis

    NASA Astrophysics Data System (ADS)

    Mechtenberg, Abigail Reid

    Human development and energy, in general, and electrical energy, specifically, co-exist seamlessly in high HDI countries where reliability and availability is greater than 99%. In numerous low HDI countries, there is 2-50% electric grid availability with reliability at or below 50% due to load shedding and faults. In Africa, solar, wind, biomass and hydroelectric energy production are cited to meet growing demand and increase reliability and availability; however, the capital costs are greater than the ability-to-pay for wide scale implementation. Since the 1970s, the United States has continued to argue over the new sustainable energy infrastructure solution(s); thus resulting in no new infrastructure being built for wide scale implementation. Together the world is facing the daunting task of averting an energy crisis in developed countries and facing energy crises in developing countries. This thesis explores the importance of energy crises: from the past, current, and future. The first part entails arguing that the United States is not on a pathway to prevent an energy crisis based on an analysis of 1986 and 2004 niche and status-quo manufacturing of light-duty vehicles. The second part answers the question of what an energy crisis looks like by exploring and investigating current electrical energy crises in Fort Portal, Uganda. This part used both anthropological and physics education empowerment research to co-design and build for various energy crisis situations in hospitals, schools, and businesses all from locally available materials and expertise. Finally, looking into the US light-duty vehicle's future, I design a new hybrid vehicle powertrain (called transition mode hybrid). This third part describes my new patent as a way to avert an energy crisis in the light-duty transportation sector.

  15. Developing and testing a street audit tool using Google Street View to measure environmental supportiveness for physical activity.

    PubMed

    Griew, Pippa; Hillsdon, Melvyn; Foster, Charlie; Coombes, Emma; Jones, Andy; Wilkinson, Paul

    2013-08-23

    Walking for physical activity is associated with substantial health benefits for adults. Increasingly research has focused on associations between walking behaviours and neighbourhood environments including street characteristics such as pavement availability and aesthetics. Nevertheless, objective assessment of street-level data is challenging. This research investigates the reliability of a new street characteristic audit tool designed for use with Google Street View, and assesses levels of agreement between computer-based and on-site auditing. The Forty Area STudy street VIEW (FASTVIEW) tool, a Google Street View based audit tool, was developed incorporating nine categories of street characteristics. Using the tool, desk-based audits were conducted by trained researchers across one large UK town during 2011. Both inter and intra-rater reliability were assessed. On-site street audits were also completed to test the criterion validity of the method. All reliability scores were assessed by percentage agreement and the kappa statistic. Within-rater agreement was high for each category of street characteristic (range: 66.7%-90.0%) and good to high between raters (range: 51.3%-89.1%). A high level of agreement was found between the Google Street View audits and those conducted in-person across the nine categories examined (range: 75.0%-96.7%). The audit tool was found to provide a reliable and valid measure of street characteristics. The use of Google Street View to capture street characteristic data is recommended as an efficient method that could substantially increase potential for large-scale objective data collection.

  16. 76 FR 16240 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ... Standards. The Reliability Standards were designed to prevent instability, uncontrolled separation, or... designed to prevent instability, uncontrolled separation, or cascading outages that adversely impact the... instability, uncontrolled separation, or cascading outages. See NERC Glossary, available at http://www.nerc...

  17. How reliable are clinical systems in the UK NHS? A study of seven NHS organisations

    PubMed Central

    Franklin, Bryony Dean; Moorthy, Krishna; Cooke, Matthew W; Vincent, Charles

    2012-01-01

    Background It is well known that many healthcare systems have poor reliability; however, the size and pervasiveness of this problem and its impact has not been systematically established in the UK. The authors studied four clinical systems: clinical information in surgical outpatient clinics, prescribing for hospital inpatients, equipment in theatres, and insertion of peripheral intravenous lines. The aim was to describe the nature, extent and variation in reliability of these four systems in a sample of UK hospitals, and to explore the reasons for poor reliability. Methods Seven UK hospital organisations were involved; each system was studied in three of these. The authors took delivery of the systems' intended outputs to be a proxy for the reliability of the system as a whole. For example, for clinical information, 100% reliability was defined as all patients having an agreed list of clinical information available when needed during their appointment. Systems factors were explored using semi-structured interviews with key informants. Common themes across the systems were identified. Results Overall reliability was found to be between 81% and 87% for the systems studied, with significant variation between organisations for some systems: clinical information in outpatient clinics ranged from 73% to 96%; prescribing for hospital inpatients 82–88%; equipment availability in theatres 63–88%; and availability of equipment for insertion of peripheral intravenous lines 80–88%. One in five reliability failures were associated with perceived threats to patient safety. Common factors causing poor reliability included lack of feedback, lack of standardisation, and issues such as access to information out of working hours. Conclusions Reported reliability was low for the four systems studied, with some common factors behind each. However, this hides significant variation between organisations for some processes, suggesting that some organisations have managed to create more reliable systems. Standardisation of processes would be expected to have significant benefit. PMID:22495099

  18. 75 FR 26057 - Mandatory Reliability Standards for the Calculation of Available Transfer Capability, Capacity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... Requirement R3.1 of MOD-001-1. C. Benchmarking 14. In the Final Rule, the Commission directed the ERO to develop benchmarking and updating requirements for the MOD Reliability Standards to measure modeled... requirements should specify the frequency for benchmarking and updating the available transfer and flowgate...

  19. Tutorial: Performance and reliability in redundant disk arrays

    NASA Technical Reports Server (NTRS)

    Gibson, Garth A.

    1993-01-01

    A disk array is a collection of physically small magnetic disks that is packaged as a single unit but operates in parallel. Disk arrays capitalize on the availability of small-diameter disks from a price-competitive market to provide the cost, volume, and capacity of current disk systems but many times their performance. Unfortunately, relative to current disk systems, the larger number of components in disk arrays leads to higher rates of failure. To tolerate failures, redundant disk arrays devote a fraction of their capacity to an encoding of their information. This redundant information enables the contents of a failed disk to be recovered from the contents of non-failed disks. The simplest and least expensive encoding for this redundancy, known as N+1 parity is highlighted. In addition to compensating for the higher failure rates of disk arrays, redundancy allows highly reliable secondary storage systems to be built much more cost-effectively than is now achieved in conventional duplicated disks. Disk arrays that combine redundancy with the parallelism of many small-diameter disks are often called Redundant Arrays of Inexpensive Disks (RAID). This combination promises improvements to both the performance and the reliability of secondary storage. For example, IBM's premier disk product, the IBM 3390, is compared to a redundant disk array constructed of 84 IBM 0661 3 1/2-inch disks. The redundant disk array has comparable or superior values for each of the metrics given and appears likely to cost less. In the first section of this tutorial, I explain how disk arrays exploit the emergence of high performance, small magnetic disks to provide cost-effective disk parallelism that combats the access and transfer gap problems. The flexibility of disk-array configurations benefits manufacturer and consumer alike. In contrast, I describe in this tutorial's second half how parallelism, achieved through increasing numbers of components, causes overall failure rates to rise. Redundant disk arrays overcome this threat to data reliability by ensuring that data remains available during and after component failures.

  20. Efficient Network Coding-Based Loss Recovery for Reliable Multicast in Wireless Networks

    NASA Astrophysics Data System (ADS)

    Chi, Kaikai; Jiang, Xiaohong; Ye, Baoliu; Horiguchi, Susumu

    Recently, network coding has been applied to the loss recovery of reliable multicast in wireless networks [19], where multiple lost packets are XOR-ed together as one packet and forwarded via single retransmission, resulting in a significant reduction of bandwidth consumption. In this paper, we first prove that maximizing the number of lost packets for XOR-ing, which is the key part of the available network coding-based reliable multicast schemes, is actually a complex NP-complete problem. To address this limitation, we then propose an efficient heuristic algorithm for finding an approximately optimal solution of this optimization problem. Furthermore, we show that the packet coding principle of maximizing the number of lost packets for XOR-ing sometimes cannot fully exploit the potential coding opportunities, and we then further propose new heuristic-based schemes with a new coding principle. Simulation results demonstrate that the heuristic-based schemes have very low computational complexity and can achieve almost the same transmission efficiency as the current coding-based high-complexity schemes. Furthermore, the heuristic-based schemes with the new coding principle not only have very low complexity, but also slightly outperform the current high-complexity ones.

  1. Expediting topology data gathering for the TOPDB database.

    PubMed

    Dobson, László; Langó, Tamás; Reményi, István; Tusnády, Gábor E

    2015-01-01

    The Topology Data Bank of Transmembrane Proteins (TOPDB, http://topdb.enzim.ttk.mta.hu) contains experimentally determined topology data of transmembrane proteins. Recently, we have updated TOPDB from several sources and utilized a newly developed topology prediction algorithm to determine the most reliable topology using the results of experiments as constraints. In addition to collecting the experimentally determined topology data published in the last couple of years, we gathered topographies defined by the TMDET algorithm using 3D structures from the PDBTM. Results of global topology analysis of various organisms as well as topology data generated by high throughput techniques, like the sequential positions of N- or O-glycosylations were incorporated into the TOPDB database. Moreover, a new algorithm was developed to integrate scattered topology data from various publicly available databases and a new method was introduced to measure the reliability of predicted topologies. We show that reliability values highly correlate with the per protein topology accuracy of the utilized prediction method. Altogether, more than 52,000 new topology data and more than 2600 new transmembrane proteins have been collected since the last public release of the TOPDB database. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  2. Ultrastrong Polyoxyzole Nanofiber Membranes for Dendrite-Proof and Heat-Resistant Battery Separators.

    PubMed

    Hao, Xiaoming; Zhu, Jian; Jiang, Xiong; Wu, Haitao; Qiao, Jinshuo; Sun, Wang; Wang, Zhenhua; Sun, Kening

    2016-05-11

    Polymeric nanomaterials emerge as key building blocks for engineering materials in a variety of applications. In particular, the high modulus polymeric nanofibers are suitable to prepare flexible yet strong membrane separators to prevent the growth and penetration of lithium dendrites for safe and reliable high energy lithium metal-based batteries. High ionic conductance, scalability, and low cost are other required attributes of the separator important for practical implementations. Available materials so far are difficult to comply with such stringent criteria. Here, we demonstrate a high-yield exfoliation of ultrastrong poly(p-phenylene benzobisoxazole) nanofibers from the Zylon microfibers. A highly scalable blade casting process is used to assemble these nanofibers into nanoporous membranes. These membranes possess ultimate strengths of 525 MPa, Young's moduli of 20 GPa, thermal stability up to 600 °C, and impressively low ionic resistance, enabling their use as dendrite-suppressing membrane separators in electrochemical cells. With such high-performance separators, reliable lithium-metal based batteries operated at 150 °C are also demonstrated. Those polyoxyzole nanofibers would enrich the existing library of strong nanomaterials and serve as a promising material for large-scale and cost-effective safe energy storage.

  3. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

    PubMed

    Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A

    2015-05-01

    Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  4. RELAV - RELIABILITY/AVAILABILITY ANALYSIS PROGRAM

    NASA Technical Reports Server (NTRS)

    Bowerman, P. N.

    1994-01-01

    RELAV (Reliability/Availability Analysis Program) is a comprehensive analytical tool to determine the reliability or availability of any general system which can be modeled as embedded k-out-of-n groups of items (components) and/or subgroups. Both ground and flight systems at NASA's Jet Propulsion Laboratory have utilized this program. RELAV can assess current system performance during the later testing phases of a system design, as well as model candidate designs/architectures or validate and form predictions during the early phases of a design. Systems are commonly modeled as System Block Diagrams (SBDs). RELAV calculates the success probability of each group of items and/or subgroups within the system assuming k-out-of-n operating rules apply for each group. The program operates on a folding basis; i.e. it works its way towards the system level from the most embedded level by folding related groups into single components. The entire folding process involves probabilities; therefore, availability problems are performed in terms of the probability of success, and reliability problems are performed for specific mission lengths. An enhanced cumulative binomial algorithm is used for groups where all probabilities are equal, while a fast algorithm based upon "Computing k-out-of-n System Reliability", Barlow & Heidtmann, IEEE TRANSACTIONS ON RELIABILITY, October 1984, is used for groups with unequal probabilities. Inputs to the program include a description of the system and any one of the following: 1) availabilities of the items, 2) mean time between failures and mean time to repairs for the items from which availabilities are calculated, 3) mean time between failures and mission length(s) from which reliabilities are calculated, or 4) failure rates and mission length(s) from which reliabilities are calculated. The results are probabilities of success of each group and the system in the given configuration. RELAV assumes exponential failure distributions for reliability calculations and infinite repair resources for availability calculations. No more than 967 items or groups can be modeled by RELAV. If larger problems can be broken into subsystems of 967 items or less, the subsystem results can be used as item inputs to a system problem. The calculated availabilities are steady-state values. Group results are presented in the order in which they were calculated (from the most embedded level out to the system level). This provides a good mechanism to perform trade studies. Starting from the system result and working backwards, the granularity gets finer; therefore, system elements that contribute most to system degradation are detected quickly. RELAV is a C-language program originally developed under the UNIX operating system on a MASSCOMP MC500 computer. It has been modified, as necessary, and ported to an IBM PC compatible with a math coprocessor. The current version of the program runs in the DOS environment and requires a Turbo C vers. 2.0 compiler. RELAV has a memory requirement of 103 KB and was developed in 1989. RELAV is a copyrighted work with all copyright vested in NASA.

  5. The impact of rare earth cobalt permanent magnets on electromechanical device design

    NASA Technical Reports Server (NTRS)

    Fisher, R. L.; Studer, P. A.

    1979-01-01

    Specific motor designs which employ rare earth cobalt magnets are discussed with special emphasis on their unique properties and magnetic field geometry. In addition to performance improvements and power savings, high reliability devices are attainable. Both the mechanism and systems engineering should be aware of the new performance levels which are currently becoming available as a result of the rare earth cobalt magnets.

  6. Highly Accurate Quartic Force Fields, Vibrational Frequencies, and Spectroscopic Constants for Cyclic and Linear C3H3(+)

    NASA Technical Reports Server (NTRS)

    Huang, Xinchuan; Taylor, Peter R.; Lee, Timothy J.

    2011-01-01

    High levels of theory have been used to compute quartic force fields (QFFs) for the cyclic and linear forms of the C H + molecular cation, referred to as c-C H + and I-C H +. Specifically the 33 3333 singles and doubles coupled-cluster method that includes a perturbational estimate of connected triple excitations, CCSD(T), has been used in conjunction with extrapolation to the one-particle basis set limit and corrections for scalar relativity and core correlation have been included. The QFFs have been used to compute highly accurate fundamental vibrational frequencies and other spectroscopic constants using both vibrational 2nd-order perturbation theory and variational methods to solve the nuclear Schroedinger equation. Agreement between our best computed fundamental vibrational frequencies and recent infrared photodissociation experiments is reasonable for most bands, but there are a few exceptions. Possible sources for the discrepancies are discussed. We determine the energy difference between the cyclic and linear forms of C H +, 33 obtaining 27.9 kcal/mol at 0 K, which should be the most reliable available. It is expected that the fundamental vibrational frequencies and spectroscopic constants presented here for c-C H + 33 and I-C H + are the most reliable available for the free gas-phase species and it is hoped that 33 these will be useful in the assignment of future high-resolution laboratory experiments or astronomical observations.

  7. PCA leverage: outlier detection for high-dimensional functional magnetic resonance imaging data.

    PubMed

    Mejia, Amanda F; Nebel, Mary Beth; Eloyan, Ani; Caffo, Brian; Lindquist, Martin A

    2017-07-01

    Outlier detection for high-dimensional (HD) data is a popular topic in modern statistical research. However, one source of HD data that has received relatively little attention is functional magnetic resonance images (fMRI), which consists of hundreds of thousands of measurements sampled at hundreds of time points. At a time when the availability of fMRI data is rapidly growing-primarily through large, publicly available grassroots datasets-automated quality control and outlier detection methods are greatly needed. We propose principal components analysis (PCA) leverage and demonstrate how it can be used to identify outlying time points in an fMRI run. Furthermore, PCA leverage is a measure of the influence of each observation on the estimation of principal components, which are often of interest in fMRI data. We also propose an alternative measure, PCA robust distance, which is less sensitive to outliers and has controllable statistical properties. The proposed methods are validated through simulation studies and are shown to be highly accurate. We also conduct a reliability study using resting-state fMRI data from the Autism Brain Imaging Data Exchange and find that removal of outliers using the proposed methods results in more reliable estimation of subject-level resting-state networks using independent components analysis. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. A rating instrument for fear of hospitalisation.

    PubMed

    Jankovic, Slobodan M; Antonijevic, Gordana V; Vasic, Ivana R; Zivkovic-Radojevic, Marija N; Mirkovic, Snjezana N; Nikolic, Bosko V; Opancina, Valentina D; Putnik, Srdjan S; Radoicic, Ljiljana R; Raspopovic, Katarina M; Stanojevic, Dragan R; Teofilov, Sladjana D; Tomasevic, Katarina V; Radonjic, Vesela

    2018-04-01

    To develop and validate a reliable instrument that can measure fear of hospitalisation experienced by outpatients. After having a diagnosis established, some patients experience sense of fear, unpleasantness and embarrassment due to the possibility to be admitted to a hospital. Currently, there is no available instrument for measuring fear of hospitalisation. Cross-sectional study for assessing reliability and validity of a questionnaire. The questionnaire with 17 items and answers according to the Likert scale was developed during two brainstorming sessions of the research team. Its reliability, validity and temporal stability were tested on the sample of 330 outpatients. The study was multicentric, involving patients from seven cities and three countries. Fear of hospitalisation scale showed satisfactory reliability, when rated both by the investigators (Cronbach's alpha .799) and by the patients themselves (Cronbach's alpha .760). It is temporally stable, and both divergent and convergent validity tests had good results. Factorial analysis revealed three domains: fear of being injured, trust to medical staff and fear of losing privacy or autonomy. This study developed new reliable and valid instrument for measuring fear of hospitalisation. Identification of patients with high level of fear of hospitalisation by this instrument should help clinicians to administer measures which may decrease fear and prevent avoidance of healthcare utilisation. © 2018 John Wiley & Sons Ltd.

  9. The poor quality and reliability of information on periacetabular osteotomy on the internet in Japan.

    PubMed

    Takegami, Yasuhiko; Seki, Taisuke; Amano, Takafumi; Higuchi, Yoshitoshi; Komatsu, Daigo; Nishida, Yoshihiro; Ishiguro, Naoki

    2017-08-01

    Although many patients use the internet to access health-related information, the quality and the reliability of the information is highly inconsistent. Periacetabular osteotomy (PAO) is one of the surgical procedures for hip dysplasia. However, medical information on PAO is limited on the internet. This study aims to evaluate the quality and reliability of information available on PAO on the internet in Japan. A web search was conducted on two search engines for the following terms: "hip osteotomy," "pelvic osteotomy," and "osteotomy for hip preservation" in Japanese. In total, we found 120 websites. To determine the quality and reliability of information on each website, we used the Health on the Net Foundation (HON) score, the Brief DISCERN score, and an osteotomy-specific content (OSC) score. After eliminating duplicate websites, we reviewed 49 unique websites. Only three websites (6.1%) had good reliability, as indicated by their HON scores. Twelve websites (24.4%) had good-quality information, as measured by their Brief DISCERN scores. As evaluated by their OSC scores, physician websites were found to be biased toward etiology and surgical indication and did not provide information on the complications of procedures. Non-physician websites were generally insufficient. The information about PAO on the internet is, therefore, unreliable and of poor-quality for Japanese patients.

  10. Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity

    PubMed Central

    Nicholas, Kevin; Sparkes, Valerie; Sheeran, Liba; Davies, Jennifer L

    2018-01-01

    The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater) reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements. PMID:29495600

  11. High-Performance I/O: HDF5 for Lattice QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurth, Thorsten; Pochinsky, Andrew; Sarje, Abhinav

    2015-01-01

    Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design andmore » implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.« less

  12. High-Performance I/O: HDF5 for Lattice QCD

    DOE PAGES

    Kurth, Thorsten; Pochinsky, Andrew; Sarje, Abhinav; ...

    2017-05-09

    Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design andmore » implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.« less

  13. Silicon Photo-Multiplier Readouts for Scintillators in High-Energy Astronomy

    NASA Technical Reports Server (NTRS)

    Bloser, Peter F.; Legere, Jason S.; Bancroft, Christopher M.; McConnell, Mark L.; Ryan, James M.

    2008-01-01

    New scintillator materials have recently been shown to hold great potential for low-cost, reliable gamma-ray detectors in high-energy astronomy. New devices for the detection of scintillation light promise to make scintillator-based instruments even more attractive by reducing mass and power requirements,in particular, silicon photo-multipliers (SiPMs) are starting to become commercially available that offer gains and quantum efficiencies similar to those of photo-multiplier tubes (PMTs), but with greatly reduced mass, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. We have conducted laboratory tests of a sample of commercially available SiPMs coupled to LaBr3;Ce, a scintillator of relevance to to future high-energy astrophysics missions. We present results for gamma-ray spectroscopy. compare the SiPM performance to that of a PMT, and discuss the extent to which SiPMs offer significant advantages for scintillator-based space missions.

  14. Characterization and reliability of aluminum gallium nitride/gallium nitride high electron mobility transistors

    NASA Astrophysics Data System (ADS)

    Douglas, Erica Ann

    Compound semiconductor devices, particularly those based on GaN, have found significant use in military and civilian systems for both microwave and optoelectronic applications. Future uses in ultra-high power radar systems will require the use of GaN transistors operated at very high voltages, currents and temperatures. GaN-based high electron mobility transistors (HEMTs) have proven power handling capability that overshadows all other wide band gap semiconductor devices for high frequency and high-power applications. Little conclusive research has been reported in order to determine the dominating degradation mechanisms of the devices that result in failure under standard operating conditions in the field. Therefore, it is imperative that further reliability testing be carried out to determine the failure mechanisms present in GaN HEMTs in order to improve device performance, and thus further the ability for future technologies to be developed. In order to obtain a better understanding of the true reliability of AlGaN/GaN HEMTs and determine the MTTF under standard operating conditions, it is crucial to investigate the interaction effects between thermal and electrical degradation. This research spans device characterization, device reliability, and device simulation in order to obtain an all-encompassing picture of the device physics. Initially, finite element thermal simulations were performed to investigate the effect of device design on self-heating under high power operation. This was then followed by a study of reliability of HEMTs and other tests structures during high power dc operation. Test structures without Schottky contacts showed high stability as compared to HEMTs, indicating that degradation of the gate is the reason for permanent device degradation. High reverse bias of the gate has been shown to induce the inverse piezoelectric effect, resulting in a sharp increase in gate leakage current due to crack formation. The introduction of elevated temperatures during high reverse gate bias indicated that device failure is due to the breakdown of an unintentional gate oxide. RF stress of AlGaN/GaN HEMTs showed comparable critical voltage breakdown regime as that of similar devices stressed under dc conditions. Though RF device characteristics showed stability up to a drain bias of 20 V, Schottky diode characteristics degraded substantially at all voltages investigated. Results from both dc and RF stress conditions, under several bias regimes, confirm that the primary root for stress induced degradation was due to the Schottky contact. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)

  15. Reliability of muscle strength assessment in chronic post-stroke hemiparesis: a systematic review and meta-analysis.

    PubMed

    Rabelo, Michelle; Nunes, Guilherme S; da Costa Amante, Natália Menezes; de Noronha, Marcos; Fachin-Martins, Emerson

    2016-02-01

    Muscle weakness is the main cause of motor impairment among stroke survivors and is associated with reduced peak muscle torque. To systematically investigate and organize the evidence of the reliability of muscle strength evaluation measures in post-stroke survivors with chronic hemiparesis. Two assessors independently searched four electronic databases in January 2014 (Medline, Scielo, CINAHL, Embase). Inclusion criteria comprised studies on reliability on muscle strength assessment in adult post-stroke patients with chronic hemiparesis. We extracted outcomes from included studies about reliability data, measured by intraclass correlation coefficient (ICC) and/or similar. The meta-analyses were conducted only with isokinetic data. Of 450 articles, eight articles were included for this review. After quality analysis, two studies were considered of high quality. Five different joints were analyzed within the included studies (knee, hip, ankle, shoulder, and elbow). Their reliability results varying from low to very high reliability (ICCs from 0.48 to 0.99). Results of meta-analysis for knee extension varying from high to very high reliability (pooled ICCs from 0.89 to 0.97), for knee flexion varying from high to very high reliability (pooled ICCs from 0.84 to 0.91) and for ankle plantar flexion showed high reliability (pooled ICC = 0.85). Objective muscle strength assessment can be reliably used in lower and upper extremities in post-stroke patients with chronic hemiparesis.

  16. High-efficiency high-reliability optical components for a large, high-average-power visible laser system

    NASA Astrophysics Data System (ADS)

    Taylor, John R.; Stolz, Christopher J.

    1993-08-01

    Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.

  17. High-efficiency high-reliability optical components for a large, high-average-power visible laser system

    NASA Astrophysics Data System (ADS)

    Taylor, J. R.; Stolz, C. J.

    1992-12-01

    Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.

  18. High single-spatial-mode pulsed power from 980 nm emitting diode lasers

    NASA Astrophysics Data System (ADS)

    Hempel, Martin; Tomm, Jens W.; Elsaesser, Thomas; Bettiati, Mauro

    2012-11-01

    Single-spatial-mode pulsed powers as high as 13 W and 20 W in 150 and 50 ns pulses, respectively, are reported for 980 nm emitting lasers. In terms of energy, single-spatial-mode values of up to 2 μJ within 150 ns pulses are shown. In this high-power pulsed operation, the devices shield themselves from facet degradation, being the main degradation source in continuous wave (cw) operation. Our results pave the way towards additional applications while employing available standard devices, which have originally been designed as very reliable cw fiber pumps.

  19. SSME component assembly and life management expert system

    NASA Technical Reports Server (NTRS)

    Ali, M.; Dietz, W. E.; Ferber, H. J.

    1989-01-01

    The space shuttle utilizes several rocket engine systems, all of which must function with a high degree of reliability for successful mission completion. The space shuttle main engine (SSME) is by far the most complex of the rocket engine systems and is designed to be reusable. The reusability of spacecraft systems introduces many problems related to testing, reliability, and logistics. Components must be assembled from parts inventories in a manner which will most effectively utilize the available parts. Assembly must be scheduled to efficiently utilize available assembly benches while still maintaining flight schedules. Assembled components must be assigned to as many contiguous flights as possible, to minimize component changes. Each component must undergo a rigorous testing program prior to flight. In addition, testing and assembly of flight engines and components must be done in conjunction with the assembly and testing of developmental engines and components. The development, testing, manufacture, and flight assignments of the engine fleet involves the satisfaction of many logistical and operational requirements, subject to many constraints. The purpose of the SSME Component Assembly and Life Management Expert System (CALMES) is to assist the engine assembly and scheduling process, and to insure that these activities utilize available resources as efficiently as possible.

  20. An imputed genotype resource for the laboratory mouse

    PubMed Central

    Szatkiewicz, Jin P.; Beane, Glen L.; Ding, Yueming; Hutchins, Lucie; de Villena, Fernando Pardo-Manuel; Churchill, Gary A.

    2009-01-01

    We have created a high-density SNP resource encompassing 7.87 million polymorphic loci across 49 inbred mouse strains of the laboratory mouse by combining data available from public databases and training a hidden Markov model to impute missing genotypes in the combined data. The strong linkage disequilibrium found in dense sets of SNP markers in the laboratory mouse provides the basis for accurate imputation. Using genotypes from eight independent SNP resources, we empirically validated the quality of the imputed genotypes and demonstrate that they are highly reliable for most inbred strains. The imputed SNP resource will be useful for studies of natural variation and complex traits. It will facilitate association study designs by providing high density SNP genotypes for large numbers of mouse strains. We anticipate that this resource will continue to evolve as new genotype data become available for laboratory mouse strains. The data are available for bulk download or query at http://cgd.jax.org/. PMID:18301946

  1. Species identification of adult African blowflies (Diptera: Calliphoridae) of forensic importance.

    PubMed

    Lutz, Lena; Williams, Kirstin A; Villet, Martin H; Ekanem, Mfon; Szpila, Krzysztof

    2018-05-01

    Necrophagous blowflies can provide an excellent source of evidence for forensic entomologists and are also relevant to problems in public health, medicine, and animal health. However, access to useful information about these blowflies is constrained by the need to correctly identify the flies, and the poor availability of reliable, accessible identification tools is a serious obstacle to the development of forensic entomology in the majority of African countries. In response to this need, a high-quality key to the adults of all species of forensically relevant blowflies of Africa has been prepared, drawing on high-quality entomological materials and modern focus-stacking photomicroscopy. This new key can be easily applied by investigators inexperienced in the taxonomy of blowflies and is made available through a highly accessible online platform. Problematic diagnostic characters used in previous keys are discussed.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurth, Thorsten; Pochinsky, Andrew; Sarje, Abhinav

    Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design andmore » implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.« less

  3. Genomic prediction using imputed whole-genome sequence data in Holstein Friesian cattle.

    PubMed

    van Binsbergen, Rianne; Calus, Mario P L; Bink, Marco C A M; van Eeuwijk, Fred A; Schrooten, Chris; Veerkamp, Roel F

    2015-09-17

    In contrast to currently used single nucleotide polymorphism (SNP) panels, the use of whole-genome sequence data is expected to enable the direct estimation of the effects of causal mutations on a given trait. This could lead to higher reliabilities of genomic predictions compared to those based on SNP genotypes. Also, at each generation of selection, recombination events between a SNP and a mutation can cause decay in reliability of genomic predictions based on markers rather than on the causal variants. Our objective was to investigate the use of imputed whole-genome sequence genotypes versus high-density SNP genotypes on (the persistency of) the reliability of genomic predictions using real cattle data. Highly accurate phenotypes based on daughter performance and Illumina BovineHD Beadchip genotypes were available for 5503 Holstein Friesian bulls. The BovineHD genotypes (631,428 SNPs) of each bull were used to impute whole-genome sequence genotypes (12,590,056 SNPs) using the Beagle software. Imputation was done using a multi-breed reference panel of 429 sequenced individuals. Genomic estimated breeding values for three traits were predicted using a Bayesian stochastic search variable selection (BSSVS) model and a genome-enabled best linear unbiased prediction model (GBLUP). Reliabilities of predictions were based on 2087 validation bulls, while the other 3416 bulls were used for training. Prediction reliabilities ranged from 0.37 to 0.52. BSSVS performed better than GBLUP in all cases. Reliabilities of genomic predictions were slightly lower with imputed sequence data than with BovineHD chip data. Also, the reliabilities tended to be lower for both sequence data and BovineHD chip data when relationships between training animals were low. No increase in persistency of prediction reliability using imputed sequence data was observed. Compared to BovineHD genotype data, using imputed sequence data for genomic prediction produced no advantage. To investigate the putative advantage of genomic prediction using (imputed) sequence data, a training set with a larger number of individuals that are distantly related to each other and genomic prediction models that incorporate biological information on the SNPs or that apply stricter SNP pre-selection should be considered.

  4. Texture and haptic cues in slant discrimination: reliability-based cue weighting without statistically optimal cue combination

    NASA Astrophysics Data System (ADS)

    Rosas, Pedro; Wagemans, Johan; Ernst, Marc O.; Wichmann, Felix A.

    2005-05-01

    A number of models of depth-cue combination suggest that the final depth percept results from a weighted average of independent depth estimates based on the different cues available. The weight of each cue in such an average is thought to depend on the reliability of each cue. In principle, such a depth estimation could be statistically optimal in the sense of producing the minimum-variance unbiased estimator that can be constructed from the available information. Here we test such models by using visual and haptic depth information. Different texture types produce differences in slant-discrimination performance, thus providing a means for testing a reliability-sensitive cue-combination model with texture as one of the cues to slant. Our results show that the weights for the cues were generally sensitive to their reliability but fell short of statistically optimal combination - we find reliability-based reweighting but not statistically optimal cue combination.

  5. Tightly-Coupled Integration of Multi-GNSS Single-Frequency RTK and MEMS-IMU for Enhanced Positioning Performance

    PubMed Central

    Li, Tuan; Zhang, Hongping; Niu, Xiaoji; Gao, Zhouzheng

    2017-01-01

    Dual-frequency Global Positioning System (GPS) Real-time Kinematics (RTK) has been proven in the past few years to be a reliable and efficient technique to obtain high accuracy positioning. However, there are still challenges for GPS single-frequency RTK, such as low reliability and ambiguity resolution (AR) success rate, especially in kinematic environments. Recently, multi-Global Navigation Satellite System (multi-GNSS) has been applied to enhance the RTK performance in terms of availability and reliability of AR. In order to further enhance the multi-GNSS single-frequency RTK performance in terms of reliability, continuity and accuracy, a low-cost micro-electro-mechanical system (MEMS) inertial measurement unit (IMU) is adopted in this contribution. We tightly integrate the single-frequency GPS/BeiDou/GLONASS and MEMS-IMU through the extended Kalman filter (EKF), which directly fuses the ambiguity-fixed double-differenced (DD) carrier phase observables and IMU data. A field vehicular test was carried out to evaluate the impacts of the multi-GNSS and IMU on the AR and positioning performance in different system configurations. Test results indicate that the empirical success rate of single-epoch AR for the tightly-coupled single-frequency multi-GNSS RTK/INS integration is over 99% even at an elevation cut-off angle of 40°, and the corresponding position time series is much more stable in comparison with the GPS solution. Besides, GNSS outage simulations show that continuous positioning with certain accuracy is possible due to the INS bridging capability when GNSS positioning is not available. PMID:29077070

  6. Tightly-Coupled Integration of Multi-GNSS Single-Frequency RTK and MEMS-IMU for Enhanced Positioning Performance.

    PubMed

    Li, Tuan; Zhang, Hongping; Niu, Xiaoji; Gao, Zhouzheng

    2017-10-27

    Dual-frequency Global Positioning System (GPS) Real-time Kinematics (RTK) has been proven in the past few years to be a reliable and efficient technique to obtain high accuracy positioning. However, there are still challenges for GPS single-frequency RTK, such as low reliability and ambiguity resolution (AR) success rate, especially in kinematic environments. Recently, multi-Global Navigation Satellite System (multi-GNSS) has been applied to enhance the RTK performance in terms of availability and reliability of AR. In order to further enhance the multi-GNSS single-frequency RTK performance in terms of reliability, continuity and accuracy, a low-cost micro-electro-mechanical system (MEMS) inertial measurement unit (IMU) is adopted in this contribution. We tightly integrate the single-frequency GPS/BeiDou/GLONASS and MEMS-IMU through the extended Kalman filter (EKF), which directly fuses the ambiguity-fixed double-differenced (DD) carrier phase observables and IMU data. A field vehicular test was carried out to evaluate the impacts of the multi-GNSS and IMU on the AR and positioning performance in different system configurations. Test results indicate that the empirical success rate of single-epoch AR for the tightly-coupled single-frequency multi-GNSS RTK/INS integration is over 99% even at an elevation cut-off angle of 40°, and the corresponding position time series is much more stable in comparison with the GPS solution. Besides, GNSS outage simulations show that continuous positioning with certain accuracy is possible due to the INS bridging capability when GNSS positioning is not available.

  7. ALCHEMY: a reliable method for automated SNP genotype calling for small batch sizes and highly homozygous populations

    PubMed Central

    Wright, Mark H.; Tung, Chih-Wei; Zhao, Keyan; Reynolds, Andy; McCouch, Susan R.; Bustamante, Carlos D.

    2010-01-01

    Motivation: The development of new high-throughput genotyping products requires a significant investment in testing and training samples to evaluate and optimize the product before it can be used reliably on new samples. One reason for this is current methods for automated calling of genotypes are based on clustering approaches which require a large number of samples to be analyzed simultaneously, or an extensive training dataset to seed clusters. In systems where inbred samples are of primary interest, current clustering approaches perform poorly due to the inability to clearly identify a heterozygote cluster. Results: As part of the development of two custom single nucleotide polymorphism genotyping products for Oryza sativa (domestic rice), we have developed a new genotype calling algorithm called ‘ALCHEMY’ based on statistical modeling of the raw intensity data rather than modelless clustering. A novel feature of the model is the ability to estimate and incorporate inbreeding information on a per sample basis allowing accurate genotyping of both inbred and heterozygous samples even when analyzed simultaneously. Since clustering is not used explicitly, ALCHEMY performs well on small sample sizes with accuracy exceeding 99% with as few as 18 samples. Availability: ALCHEMY is available for both commercial and academic use free of charge and distributed under the GNU General Public License at http://alchemy.sourceforge.net/ Contact: mhw6@cornell.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:20926420

  8. Fostered Thermomagnetic Stabilities and Boosted Mechanical Reliability Related to High Trapped Field in Composite Bulk YBa2Cu3O(7-δ) Cryomagnets.

    PubMed

    Kenfaui, Driss; Sibeud, Pierre-Frédéric; Gomina, Moussa; Louradour, Eric; Chaud, Xavier; Noudem, Jacques G

    2015-08-06

    In the quest of YBa2Cu3O(7-δ) (Y123) bulk superconductors providing strong magnetic fields without failure, it is of paramount importance to achieve high thermal stabilities to safeguard the magnetic energy inside them during the trapping-field process, and sufficient mechanical reliability to withstand the stresses derived from the Lorenz force. Herein, we experimentally demonstrate a temperature rise induced by dissipative flux motion inside an Y123 thin-wall superconductor, and a significant thermal exchange in a composite bulk Y123 cryomagnet realized by embedding this superconductor with high thermal-conductivity metal network. It resulted in stimulating the maximum trapped field Bm, which reached 6.46 T on 15.9 mm-diameter single disk superconductor after magnetization by field cooling to 17 K under 7 T, leading to an improvement of 18% compared to the thin-wall superconductor. The composite cryomagnet particularly revealed the potential to trap stronger fields if larger magnetic activation is available. By virtue of the pore-free and crack-free microstructure of this cryomagnet, its strength σR was estimated to be 363 MPa, the largest one obtained so far for Y123 bulk superconductors, thus suggesting a striking mechanical reliability that seems to be sufficient to sustain stresses derived from trapped fields stronger than any values hitherto reported.

  9. FEMA and RAM Analysis for the Multi Canister Overpack (MCO) Handling Machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SWENSON, C.E.

    2000-06-01

    The Failure Modes and Effects Analysis and the Reliability, Availability, and Maintainability Analysis performed for the Multi-Canister Overpack Handling Machine (MHM) has shown that the current design provides for a safe system, but the reliability of the system (primarily due to the complexity of the interlocks and permissive controls) is relatively low. No specific failure modes were identified where significant consequences to the public occurred, or where significant impact to nearby workers should be expected. The overall reliability calculation for the MHM shows a 98.1 percent probability of operating for eight hours without failure, and an availability of the MHMmore » of 90 percent. The majority of the reliability issues are found in the interlocks and controls. The availability of appropriate spare parts and maintenance personnel, coupled with well written operating procedures, will play a more important role in successful mission completion for the MHM than other less complicated systems.« less

  10. Using Facility Condition Assessments to Identify Actions Related to Infrastructure

    NASA Technical Reports Server (NTRS)

    Rubert, Kennedy F.

    2010-01-01

    To support cost effective, quality research it is essential that laboratory and testing facilities are maintained in a continuous and reliable state of availability at all times. NASA Langley Research Center (LaRC) and its maintenance contractor, Jacobs Technology, Inc. Research Operations, Maintenance, and Engineering (ROME) group, are in the process of implementing a combined Facility Condition Assessment (FCA) and Reliability Centered Maintenance (RCM) program to improve asset management and overall reliability of testing equipment in facilities such as wind tunnels. Specific areas are being identified for improvement, the deferred maintenance cost is being estimated, and priority is being assigned against facilities where conditions have been allowed to deteriorate. This assessment serves to assist in determining where to commit available funds on the Center. RCM methodologies are being reviewed and enhanced to assure that appropriate preventive, predictive, and facilities/equipment acceptance techniques are incorporated to prolong lifecycle availability and assure reliability at minimum cost. The results from the program have been favorable, better enabling LaRC to manage assets prudently.

  11. Availability and End-to-end Reliability in Low Duty Cycle Multihop Wireless Sensor Networks.

    PubMed

    Suhonen, Jukka; Hämäläinen, Timo D; Hännikäinen, Marko

    2009-01-01

    A wireless sensor network (WSN) is an ad-hoc technology that may even consist of thousands of nodes, which necessitates autonomic, self-organizing and multihop operations. A typical WSN node is battery powered, which makes the network lifetime the primary concern. The highest energy efficiency is achieved with low duty cycle operation, however, this alone is not enough. WSNs are deployed for different uses, each requiring acceptable Quality of Service (QoS). Due to the unique characteristics of WSNs, such as dynamic wireless multihop routing and resource constraints, the legacy QoS metrics are not feasible as such. We give a new definition to measure and implement QoS in low duty cycle WSNs, namely availability and reliability. Then, we analyze the effect of duty cycling for reaching the availability and reliability. The results are obtained by simulations with ZigBee and proprietary TUTWSN protocols. Based on the results, we also propose a data forwarding algorithm suitable for resource constrained WSNs that guarantees end-to-end reliability while adding a small overhead that is relative to the packet error rate (PER). The forwarding algorithm guarantees reliability up to 30% PER.

  12. A reliable in vitro fruiting system for armillaria mellea for evaluation of agrobacterium tumefaciens transformation vectors

    USDA-ARS?s Scientific Manuscript database

    Armillaria mellea is a serious pathogen of horticultural and agricultural systems in Europe and North America. The lack of a reliable in vitro fruiting system has hindered research, and necessitated dependence on intermittently available wild-collected basidiospores. Here we describe a reliable, rep...

  13. 75 FR 4375 - Transmission Loading Relief Reliability Standard and Curtailment Priorities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... Site: http://www.ferc.gov . Documents created electronically using word processing software should be... ensure operation within acceptable reliability criteria. NERC Glossary of Terms Used in Reliability Standards at 19, available at http://www.nerc.com/files/Glossary_12Feb08.pdf (NERC Glossary). An...

  14. Emission of pesticides into the air

    USGS Publications Warehouse

    Van Den, Berg; Kubiak, R.; Benjey, W.G.; Majewski, M.S.; Yates, S.R.; Reeves, G.L.; Smelt, J.H.; Van Der Linden, A. M. A.

    1999-01-01

    During and after the application of a pesticide in agriculture, a substantial fraction of the dosage may enter the atmosphere and be transported over varying distances downwind of the target. The rate and extent of the emission during application, predominantly as spray particle drift, depends primarily on the application method (equipment and technique), the formulation and environmental conditions, whereas the emission after application depends primarily on the properties of the pesticide, soils, crops and environmental conditions. The fraction of the dosage that misses the target area may be high in some cases and more experimental data on this loss term are needed for various application types and weather conditions. Such data are necessary to test spray drift models, and for further model development and verification as well. Following application, the emission of soil fumigants and soil incorporated pesticides into the air can be measured and computed with reasonable accuracy, but further model development is needed to improve the reliability of the model predictions. For soil surface applied pesticides reliable measurement methods are available, but there is not yet a reliable model. Further model development is required which must be verified by field experiments. Few data are available on pesticide volatilization from plants and more field experiments are also needed to study the fate processes on the plants. Once this information is available, a model needs to be developed to predict the volatilization of pesticides from plants, which, again, should be verified with field measurements. For regional emission estimates, a link between data on the temporal and spatial pesticide use and a geographical information system for crops and soils with their characteristics is needed.

  15. Reliability of Craniofacial Superimposition Using Three-Dimension Skull Model.

    PubMed

    Gaudio, Daniel; Olivieri, Lara; De Angelis, Danilo; Poppa, Pasquale; Galassi, Andrea; Cattaneo, Cristina

    2016-01-01

    Craniofacial superimposition is a technique potentially useful for the identification of unidentified human remains if a photo of the missing person is available. We have tested the reliability of the 2D-3D computer-aided nonautomatic superimposition techniques. Three-dimension laser scans of five skulls and ten photographs were overlaid with an imaging software. The resulting superimpositions were evaluated using three methods: craniofacial landmarks, morphological features, and a combination of the two. A 3D model of each skull without its mandible was tested for superimposition; we also evaluated whether separating skulls by sex would increase correct identifications. Results show that the landmark method employing the entire skull is the more reliable one (5/5 correct identifications, 40% false positives [FP]), regardless of sex. However, the persistence of a high percentage of FP in all the methods evaluated indicates that these methods are unreliable for positive identification although the landmark-only method could be useful for exclusion. © 2015 American Academy of Forensic Sciences.

  16. Reliability of self-reported smoking history and age at initial tobacco use.

    PubMed

    Huerta, Michael; Chodick, Gabriel; Balicer, Ran D; Davidovitch, Nadav; Grotto, Itamar

    2005-08-01

    Many studies use questionnaires to determine smoking status and age of smoking onset. This study aimed to determine the reliability of self-reported smoking history and age of smoking initiation. The proportion of inconsistent answers and correlation coefficients of reported age of initial smoking were measured by an answer-reanswer analysis of questionnaires in an ongoing, two-step, population-based survey of health behavior. Interviews were conducted on the day of recruitment to and the day of discharge from mandatory military service in Israel among a sample of 25,437 young men and women recruited between 1986 and 2000. Of 7276 participants reporting current or past smoking upon recruitment, 559 (7.7%) reported never having smoked upon discharge, thus demonstrating prima facie inconsistency. Variables significantly associated with reliable reporting in a multivariate logistic regression model were female gender (P = 0.04) and more than 4 years of military service (P < 0.01). 6010 subjects who reported a positive smoking history at both recruitment and discharge were available for analysis of reliability of reported age at smoking onset. Intraclass correlation coefficients for recruitment/discharge consistency in reported age at first cigarette were 0.73 (95% CI: 0.71-0.74) and 0.76 (95% CI: 0.74-0.78) for men and women, respectively. Eastern origin, lower subject education level, and lower paternal education level were also associated with lower reliability. Our results showed a relatively high level of answer-reanswer reliability, with some variance attributable to personal characteristics. These results suggest that self-reported age at onset of tobacco use is practical and reliable in normative, young adult populations. However, time elapsed between questionnaires and demographic and lifestyle characteristics may affect reliability rates, and thus should be carefully regarded in future studies.

  17. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    PubMed Central

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A

    2018-01-01

    Purpose The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. Conclusion The TIRE measures of MIP, SMIP and ID have excellent test–retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP. PMID:29805255

  18. The Development of High Transition Temperature Superconducting Ceramic Thick Films and Wire Composites

    DTIC Science & Technology

    1991-12-02

    number of protein or sugar agents were experimented with including Agar, pectin, carboxymethylcellulose, gelatin, alginic acid, xanthan gum , guar gum ...I) Introduction and Description of Scientific Goals 1 II) Material and Powder Synthesis 1 A) Freeze Dried Fabrication of Powders 1 B) Utilization of...composites. II). Material and Powder Synthesis The availability of a reliable technique for producing large quantities of phase pure, submicron powders

  19. Reliability of Next Generation Power Electronics Packaging Under Concurrent Vibration, Thermal and High Power Loads

    DTIC Science & Technology

    2008-02-01

    combined thermal g effect and initial current field. The model is implemented using Abaqus user element subroutine and verified against the experimental...Finite Element Formulation The proposed model is implemented with ABAQUS general purpose finite element program using thermal -displacement analysis...option. ABAQUS and other commercially available finite element codes do not have the capability to solve general electromigration problem directly. Thermal

  20. Spectroscopy of the amide-I modes of acetanilide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bigio, I.J.; Scott, A.C.; Johnston, C.T.

    1989-01-01

    Raman measurements were made on acetanilide (N-phenyl-acetamide). Data are presented of the integrated intensity of the 1650 cm/sup /minus/1/ band as a function of temperature. The experimental procedures and data reduction were highly rigorous and are believed to be to most reliable data available. A concise theory of polaron states is presented and used to interpret the data. 22 refs., 4 figs., 1 tab.

  1. A Bioinformatic Pipeline for Monitoring of the Mutational Stability of Viral Drug Targets with Deep-Sequencing Technology.

    PubMed

    Kravatsky, Yuri; Chechetkin, Vladimir; Fedoseeva, Daria; Gorbacheva, Maria; Kravatskaya, Galina; Kretova, Olga; Tchurikov, Nickolai

    2017-11-23

    The efficient development of antiviral drugs, including efficient antiviral small interfering RNAs (siRNAs), requires continuous monitoring of the strict correspondence between a drug and the related highly variable viral DNA/RNA target(s). Deep sequencing is able to provide an assessment of both the general target conservation and the frequency of particular mutations in the different target sites. The aim of this study was to develop a reliable bioinformatic pipeline for the analysis of millions of short, deep sequencing reads corresponding to selected highly variable viral sequences that are drug target(s). The suggested bioinformatic pipeline combines the available programs and the ad hoc scripts based on an original algorithm of the search for the conserved targets in the deep sequencing data. We also present the statistical criteria for the threshold of reliable mutation detection and for the assessment of variations between corresponding data sets. These criteria are robust against the possible sequencing errors in the reads. As an example, the bioinformatic pipeline is applied to the study of the conservation of RNA interference (RNAi) targets in human immunodeficiency virus 1 (HIV-1) subtype A. The developed pipeline is freely available to download at the website http://virmut.eimb.ru/. Brief comments and comparisons between VirMut and other pipelines are also presented.

  2. High-Reliability Health Care: Getting There from Here

    PubMed Central

    Chassin, Mark R; Loeb, Jerod M

    2013-01-01

    Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. PMID:24028696

  3. High-reliability health care: getting there from here.

    PubMed

    Chassin, Mark R; Loeb, Jerod M

    2013-09-01

    Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. © 2013 The Authors. The Milbank Quarterly published by Wiley Periodicals Inc. on behalf of Milbank Memorial Fund.

  4. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    NASA Astrophysics Data System (ADS)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  5. The German Version of the Herth Hope Index (HHI-D): Development and Psychometric Properties.

    PubMed

    Geiser, Franziska; Zajackowski, Katharina; Conrad, Rupert; Imbierowicz, Katrin; Wegener, Ingo; Herth, Kaye A; Urbach, Anne Sarah

    2015-01-01

    The importance of hope is evident in clinical oncological care. Hope is associated with psychological and also physical functioning. However, there is still a dearth of empirical research on hope as a multidimensional concept. The Herth Hope Index is a reliable and valid instrument for the measurement of hope and is available in many languages. Until now no authorized German translation has been published and validated. After translation, the questionnaire was completed by 192 patients with different tumor entities in radiation therapy. Reliability, concurrent validity, and factor structure of the questionnaire were determined. Correlations were high with depression and anxiety as well as optimism and pessimism. As expected, correlations with coping styles were moderate. Internal consistency and test-retest reliability were satisfactory. We could not replicate the original 3-factor model. Application of the scree plot criterion in an exploratory factor analysis resulted in a single-factor structure. The Herth Hope Index - German Version (HHI-D) is a short, reliable, and valid instrument for the assessment of hope in patient populations. We recommend using only the HHI-D total score until further research gives more insights into possible factorial solutions and subscales. © 2015 S. Karger GmbH, Freiburg.

  6. Mining protein interactomes to improve their reliability and support the advancement of network medicine.

    PubMed

    Alanis-Lobato, Gregorio

    2015-01-01

    High-throughput detection of protein interactions has had a major impact in our understanding of the intricate molecular machinery underlying the living cell, and has permitted the construction of very large protein interactomes. The protein networks that are currently available are incomplete and a significant percentage of their interactions are false positives. Fortunately, the structural properties observed in good quality social or technological networks are also present in biological systems. This has encouraged the development of tools, to improve the reliability of protein networks and predict new interactions based merely on the topological characteristics of their components. Since diseases are rarely caused by the malfunction of a single protein, having a more complete and reliable interactome is crucial in order to identify groups of inter-related proteins involved in disease etiology. These system components can then be targeted with minimal collateral damage. In this article, an important number of network mining tools is reviewed, together with resources from which reliable protein interactomes can be constructed. In addition to the review, a few representative examples of how molecular and clinical data can be integrated to deepen our understanding of pathogenesis are discussed.

  7. RICOR's new development of a highly reliable integral rotary cooler: engineering and reliability aspects

    NASA Astrophysics Data System (ADS)

    Filis, Avishai; Pundak, Nachman; Barak, Moshe; Porat, Ze'ev; Jaeger, Mordechai

    2011-06-01

    The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and decreased integrated system Life Cycle (ILS) cost. In order to meet this need RICOR has developed a new rotary Stirling cryocooler, model K508N, intended to double the K508's operating MTTF achieving 20,000 operating MTTF hours. The K508N employs RICOR's latest mechanical design technologies such as optimized bearings and greases, bearings preloading, advanced seals, laser welded cold finger and robust design structure with increased natural frequency compared to the K508 model. The cooler enhanced MTTF was demonstrated by a Validation and Verification (V&V) plan comprising analytical means and a comparative accelerated life test between the standard K508 and the K508N models. Particularly, point estimate and confidence interval for the MTTF improvement factor where calculated periodically during and after the test. The (V&V) effort revealed that the K508N meets its MTTF design goal. The paper will focus on the technical and engineering aspects of the new design. In addition it will discuss the market needs and expectations, investigate the reliability data of the present reference K508 model; and report the accelerate life test data and the statistical analysis methodology as well as its underlying assumptions and results.

  8. The importance of data quality for generating reliable distribution models for rare, elusive, and cryptic species

    Treesearch

    Keith B. Aubry; Catherine M. Raley; Kevin S. McKelvey

    2017-01-01

    The availability of spatially referenced environmental data and species occurrence records in online databases enable practitioners to easily generate species distribution models (SDMs) for a broad array of taxa. Such databases often include occurrence records of unknown reliability, yet little information is available on the influence of data quality on SDMs generated...

  9. Waste Feed Delivery System Phase 1 Preliminary Reliability and Availability and Maintainability Analysis [SEC 1 and 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CARLSON, A.B.

    The document presents updated results of the preliminary reliability, availability, maintainability analysis performed for delivery of waste feed from tanks 241-AZ-101 and 241-AN-105 to British Nuclear Fuels Limited, inc. under the Tank Waste Remediation System Privatization Contract. The operational schedule delay risk is estimated and contributing factors are discussed.

  10. Intra-and inter-observer reliability of nailfold videocapillaroscopy - A possible outcome measure for systemic sclerosis-related microangiopathy.

    PubMed

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Tresadern, Philip; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-07-01

    Our aim was to assess the reliability of nailfold capillary assessment in terms of image evaluability, image severity grade ('normal', 'early', 'active', 'late'), capillary density, capillary (apex) width, and presence of giant capillaries, and also to gain further insight into differences in these parameters between patients with systemic sclerosis (SSc), patients with primary Raynaud's phenomenon (PRP) and healthy control subjects. Videocapillaroscopy images (magnification 300×) were acquired from all 10 digits from 173 participants: 101 patients with SSc, 22 with PRP and 50 healthy controls. Ten capillaroscopy experts from 7 European centres evaluated the images. Custom image mark-up software allowed extraction of the following outcome measures: overall grade ('normal', 'early', 'active', 'late', 'non-specific', or 'ungradeable'), capillary density (vessels/mm), mean vessel apical width, and presence of giant capillaries. Observers analysed a median of 129 images each. Evaluability (i.e. the availability of measures) varied across outcome measures (e.g. 73.0% for density and 46.2% for overall grade in patients with SSc). Intra-observer reliability for evaluability was consistently higher than inter- (e.g. for density, intra-class correlation coefficient [ICC] was 0.71 within and 0.14 between observers). Conditional on evaluability, both intra- and inter-observer reliability were high for grade (ICC 0.93 and 0.78 respectively), density (0.91 and 0.64) and width (0.91 and 0.85). Evaluability is one of the major challenges in assessing nailfold capillaries. However, when images are evaluable, the high intra- and inter-reliabilities suggest that overall image grade, capillary density and apex width have potential as outcome measures in longitudinal studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Narrative review: should teaching of the respiratory physical examination be restricted only to signs with proven reliability and validity?

    PubMed

    Benbassat, Jochanan; Baumal, Reuben

    2010-08-01

    To review the reported reliability (reproducibility, inter-examiner agreement) and validity (sensitivity, specificity and likelihood ratios) of respiratory physical examination (PE) signs, and suggest an approach to teaching these signs to medical students. Review of the literature. We searched Paper Chase between 1966 and June 2009 to identify and evaluate published studies on the diagnostic accuracy of respiratory PE signs. Most studies have reported low to fair reliability and sensitivity values. However, some studies have found high specificites for selected PE signs. None of the studies that we reviewed adhered to all of the STARD criteria for reporting diagnostic accuracy. Possible flaws in study designs may have led to underestimates of the observed diagnostic accuracy of respiratory PE signs. The reported poor reliabilities may have been due to differences in the PE skills of the participating examiners, while the sensitivities may have been confounded by variations in the severity of the diseases of the participating patients. IMPLICATION FOR PRACTICE AND MEDICAL EDUCATION: Pending the results of properly controlled studies, the reported poor reliability and sensitivity of most respiratory PE signs do not necessarily detract from their clinical utility. Therefore, we believe that a meticulously performed respiratory PE, which aims to explore a diagnostic hypothesis, as opposed to a PE that aims to detect a disease in an asymptomatic person, remains a cornerstone of clinical practice. We propose teaching the respiratory PE signs according to their importance, beginning with signs of life-threatening conditions and those that have been reported to have a high specificity, and ending with signs that are "nice to know," but are no longer employed because of the availability of more easily performed tests.

  12. Narrative Review: Should Teaching of the Respiratory Physical Examination Be Restricted Only to Signs with Proven Reliability and Validity?

    PubMed Central

    Baumal, Reuben

    2010-01-01

    OBJECTIVE To review the reported reliability (reproducibility, inter-examiner agreement) and validity (sensitivity, specificity and likelihood ratios) of respiratory physical examination (PE) signs, and suggest an approach to teaching these signs to medical students. METHODS Review of the literature. We searched Paper Chase between 1966 and June 2009 to identify and evaluate published studies on the diagnostic accuracy of respiratory PE signs. RESULTS Most studies have reported low to fair reliability and sensitivity values. However, some studies have found high specificites for selected PE signs. None of the studies that we reviewed adhered to all of the STARD criteria for reporting diagnostic accuracy. CONCLUSIONS Possible flaws in study designs may have led to underestimates of the observed diagnostic accuracy of respiratory PE signs. The reported poor reliabilities may have been due to differences in the PE skills of the participating examiners, while the sensitivities may have been confounded by variations in the severity of the diseases of the participating patients. IMPLICATION FOR PRACTICE AND MEDICAL EDUCATION Pending the results of properly controlled studies, the reported poor reliability and sensitivity of most respiratory PE signs do not necessarily detract from their clinical utility. Therefore, we believe that a meticulously performed respiratory PE, which aims to explore a diagnostic hypothesis, as opposed to a PE that aims to detect a disease in an asymptomatic person, remains a cornerstone of clinical practice. We propose teaching the respiratory PE signs according to their importance, beginning with signs of life-threatening conditions and those that have been reported to have a high specificity, and ending with signs that are "nice to know," but are no longer employed because of the availability of more easily performed tests. PMID:20349154

  13. Measuring human remains in the field: Grid technique, total station, or MicroScribe?

    PubMed

    Sládek, Vladimír; Galeta, Patrik; Sosna, Daniel

    2012-09-10

    Although three-dimensional (3D) coordinates for human intra-skeletal landmarks are among the most important data that anthropologists have to record in the field, little is known about the reliability of various measuring techniques. We compared the reliability of three techniques used for 3D measurement of human remain in the field: grid technique (GT), total station (TS), and MicroScribe (MS). We measured 365 field osteometric points on 12 skeletal sequences excavated at the Late Medieval/Early Modern churchyard in Všeruby, Czech Republic. We compared intra-observer, inter-observer, and inter-technique variation using mean difference (MD), mean absolute difference (MAD), standard deviation of difference (SDD), and limits of agreement (LA). All three measuring techniques can be used when accepted error ranges can be measured in centimeters. When a range of accepted error measurable in millimeters is needed, MS offers the best solution. TS can achieve the same reliability as does MS, but only when the laser beam is accurately pointed into the center of the prism. When the prism is not accurately oriented, TS produces unreliable data. TS is more sensitive to initialization than is MS. GT measures human skeleton with acceptable reliability for general purposes but insufficiently when highly accurate skeletal data are needed. We observed high inter-technique variation, indicating that just one technique should be used when spatial data from one individual are recorded. Subadults are measured with slightly lower error than are adults. The effect of maximum excavated skeletal length has little practical significance in field recording. When MS is not available, we offer practical suggestions that can help to increase reliability when measuring human skeleton in the field. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. German validation of the Conners Adult ADHD Rating Scales (CAARS) II: reliability, validity, diagnostic sensitivity and specificity.

    PubMed

    Christiansen, H; Kis, B; Hirsch, O; Matthies, S; Hebebrand, J; Uekermann, J; Abdel-Hamid, M; Kraemer, M; Wiltfang, J; Graf, E; Colla, M; Sobanski, E; Alm, B; Rösler, M; Jacob, C; Jans, T; Huss, M; Schimmelmann, B G; Philipsen, A

    2012-07-01

    The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires. CAARS-S/O and questions on sociodemographic variables were filled out by 466 patients with ADHD, 847 healthy control subjects that already participated in two prior studies, and a total of 896 observer data sets were available. Cronbach's-alpha was calculated to obtain internal reliability coefficients. Pearson correlations were performed to assess test-retest reliability, and concurrent, criterion, and discriminant validity. Receiver Operating Characteristics (ROC-analyses) were used to establish sensitivity and specificity for all subscales. Coefficient alphas ranged from .74 to .95, and test-retest reliability from .85 to .92 for the CAARS-S, and from .65 to .85 for the CAARS-O. All CAARS subscales, except problems with self-concept correlated significantly with the Barrett Impulsiveness Scale (BIS), but not with the Wender Utah Rating Scale (WURS). Criterion validity was established with ADHD subtype and diagnosis based on DSM-IV criteria. Sensitivity and specificity were high for all four subscales. The reported results confirm our previous study and show that the German CAARS-S/O do indeed represent a reliable and cross-culturally valid measure of current ADHD symptoms in adults. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  15. Interventions for Age-Related Macular Degeneration: Are Practice Guidelines Based on Systematic Reviews?

    PubMed Central

    Lindsley, Kristina; Li, Tianjing; Ssemanda, Elizabeth; Virgili, Gianni; Dickersin, Kay

    2016-01-01

    Topic Are existing systematic reviews of interventions for age-related macular degeneration incorporated into clinical practice guidelines? Clinical relevance High-quality systematic reviews should be used to underpin evidence-based clinical practice guidelines and clinical care. We have examined the reliability of systematic reviews of interventions for age-related macular degeneration (AMD) and described the main findings of reliable reviews in relation to clinical practice guidelines. Methods Eligible publications are systematic reviews of the effectiveness of treatment interventions for AMD. We searched a database of systematic reviews in eyes and vision and employed no language or date restrictions; the database is up-to-date as of May 6, 2014. Two authors independently screened records for eligibility and abstracted and assessed the characteristics and methods of each review. We classified reviews as “reliable” when they reported eligibility criteria, comprehensive searches, appraisal of methodological quality of included studies, appropriate statistical methods for meta-analysis, and conclusions based on results. We mapped treatment recommendations from the American Academy of Ophthalmology Preferred Practice Patterns (AAO PPP) for AMD to the identified systematic reviews and assessed whether any reliable systematic review was cited or could have been cited to support each treatment recommendation. Results Of 1,570 systematic reviews in our database, 47 met our inclusion criteria. Most of the systematic reviews targeted neovascular AMD and investigated anti-vascular endothelial growth factor (anti-VEGF) interventions, dietary supplements or photodynamic therapy. We classified over two-thirds (33/47) of the reports as reliable. The quality of reporting varied, with criteria for reliable reporting met more often for Cochrane reviews and for reviews whose authors disclosed conflicts of interest. Although most systematic reviews were reliable, anti-VEGF agents and photodynamic therapy were the only interventions identified as effective by reliable reviews. Of 35 treatment recommendations extracted from the AAO PPP, 15 could have been supported with reliable systematic reviews; however, only one recommendation had an accompanying intervention systematic review citation, which we assessed as a reliable systematic review. No reliable systematic review was identified for 20 treatment recommendations, highlighting areas of evidence gaps. Conclusions For AMD, reliable systematic reviews exist for many treatment recommendations in the AAO PPP and should be used to support these recommendations. We also identified areas where no high-level evidence exists. Mapping clinical practice guidelines to existing systematic reviews is one way to highlight areas where evidence generation or evidence synthesis is either available or needed. PMID:26804762

  16. Reliability and availability evaluation of Wireless Sensor Networks for industrial applications.

    PubMed

    Silva, Ivanovitch; Guedes, Luiz Affonso; Portugal, Paulo; Vasques, Francisco

    2012-01-01

    Wireless Sensor Networks (WSN) currently represent the best candidate to be adopted as the communication solution for the last mile connection in process control and monitoring applications in industrial environments. Most of these applications have stringent dependability (reliability and availability) requirements, as a system failure may result in economic losses, put people in danger or lead to environmental damages. Among the different type of faults that can lead to a system failure, permanent faults on network devices have a major impact. They can hamper communications over long periods of time and consequently disturb, or even disable, control algorithms. The lack of a structured approach enabling the evaluation of permanent faults, prevents system designers to optimize decisions that minimize these occurrences. In this work we propose a methodology based on an automatic generation of a fault tree to evaluate the reliability and availability of Wireless Sensor Networks, when permanent faults occur on network devices. The proposal supports any topology, different levels of redundancy, network reconfigurations, criticality of devices and arbitrary failure conditions. The proposed methodology is particularly suitable for the design and validation of Wireless Sensor Networks when trying to optimize its reliability and availability requirements.

  17. Reliability and Availability Evaluation of Wireless Sensor Networks for Industrial Applications

    PubMed Central

    Silva, Ivanovitch; Guedes, Luiz Affonso; Portugal, Paulo; Vasques, Francisco

    2012-01-01

    Wireless Sensor Networks (WSN) currently represent the best candidate to be adopted as the communication solution for the last mile connection in process control and monitoring applications in industrial environments. Most of these applications have stringent dependability (reliability and availability) requirements, as a system failure may result in economic losses, put people in danger or lead to environmental damages. Among the different type of faults that can lead to a system failure, permanent faults on network devices have a major impact. They can hamper communications over long periods of time and consequently disturb, or even disable, control algorithms. The lack of a structured approach enabling the evaluation of permanent faults, prevents system designers to optimize decisions that minimize these occurrences. In this work we propose a methodology based on an automatic generation of a fault tree to evaluate the reliability and availability of Wireless Sensor Networks, when permanent faults occur on network devices. The proposal supports any topology, different levels of redundancy, network reconfigurations, criticality of devices and arbitrary failure conditions. The proposed methodology is particularly suitable for the design and validation of Wireless Sensor Networks when trying to optimize its reliability and availability requirements. PMID:22368497

  18. Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation

    PubMed Central

    2014-01-01

    Background A balance test provides important information such as the standard to judge an individual’s functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Methods Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). Results The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. Conclusion The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment. PMID:24912769

  19. Validity and reliability of balance assessment software using the Nintendo Wii balance board: usability and validation.

    PubMed

    Park, Dae-Sung; Lee, GyuChang

    2014-06-10

    A balance test provides important information such as the standard to judge an individual's functional recovery or make the prediction of falls. The development of a tool for a balance test that is inexpensive and widely available is needed, especially in clinical settings. The Wii Balance Board (WBB) is designed to test balance, but there is little software used in balance tests, and there are few studies on reliability and validity. Thus, we developed a balance assessment software using the Nintendo Wii Balance Board, investigated its reliability and validity, and compared it with a laboratory-grade force platform. Twenty healthy adults participated in our study. The participants participated in the test for inter-rater reliability, intra-rater reliability, and concurrent validity. The tests were performed with balance assessment software using the Nintendo Wii balance board and a laboratory-grade force platform. Data such as Center of Pressure (COP) path length and COP velocity were acquired from the assessment systems. The inter-rater reliability, the intra-rater reliability, and concurrent validity were analyzed by an intraclass correlation coefficient (ICC) value and a standard error of measurement (SEM). The inter-rater reliability (ICC: 0.89-0.79, SEM in path length: 7.14-1.90, SEM in velocity: 0.74-0.07), intra-rater reliability (ICC: 0.92-0.70, SEM in path length: 7.59-2.04, SEM in velocity: 0.80-0.07), and concurrent validity (ICC: 0.87-0.73, SEM in path length: 5.94-0.32, SEM in velocity: 0.62-0.08) were high in terms of COP path length and COP velocity. The balance assessment software incorporating the Nintendo Wii balance board was used in our study and was found to be a reliable assessment device. In clinical settings, the device can be remarkably inexpensive, portable, and convenient for the balance assessment.

  20. Are We Hoping For A Bounce A Study On Resilience And Human Relations In A High Reliability Organization

    DTIC Science & Technology

    2016-03-01

    A BOUNCE? A STUDY ON RESILIENCE AND HUMAN RELATIONS IN A HIGH RELIABILITY ORGANIZATION by Robert D. Johns March 2016 Thesis Advisor...RELATIONS IN A HIGH RELIABILITY ORGANIZATION 5. FUNDING NUMBERS 6. AUTHOR(S) Robert D. Johns 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES...200 words) This study analyzes the various resilience factors associated with a military high reliability organization (HRO). The data measuring

  1. A comparative trial of paper-and-pencil versus computer administration of the Quality of Life in Reflux and Dyspepsia (QOLRAD) questionnaire.

    PubMed

    Kleinman, L; Leidy, N K; Crawley, J; Bonomi, A; Schoenfeld, P

    2001-02-01

    Although most health-related quality of life questionnaires are self-administered by means of paper and pencil, new technologies for automated computer administration are becoming more readily available. Novel methods of instrument administration must be assessed for score equivalence in addition to consistency in reliability and validity. The present study compared the psychometric characteristics (score equivalence and structure, internal consistency, and reproducibility reliability and construct validity) of the Quality of Life in Reflux And Dyspepsia (QOLRAD) questionnaire when self-administered by means of paper and pencil versus touch-screen computer. The influence of age, education, and prior experience with computers on score equivalence was also examined. This crossover trial randomized 134 patients with gastroesophageal reflux disease to 1 of 2 groups: paper-and-pencil questionnaire administration followed by computer administration or computer administration followed by use of paper and pencil. To minimize learning effects and respondent fatigue, administrations were scheduled 3 days apart. A random sample of 32 patients participated in a 1-week reproducibility evaluation of the computer-administered QOLRAD. QOLRAD scores were equivalent across the 2 methods of administration regardless of subject age, education, and prior computer use. Internal consistency levels were very high (alpha = 0.93-0.99). Interscale correlations were strong and generally consistent across methods (r = 0.7-0.87). Correlations between the QOLRAD and Short Form 36 (SF-36) were high, with no significant differences by method. Test-retest reliability of the computer-administered QOLRAD was also very high (ICC = 0.93-0.96). Results of the present study suggest that the QOLRAD is reliable and valid when self-administered by means of computer touch-screen or paper and pencil.

  2. English translation and validation of the SarQoL®, a quality of life questionnaire specific for sarcopenia.

    PubMed

    Beaudart, Charlotte; Edwards, Mark; Moss, Charlotte; Reginster, Jean-Yves; Moon, Rebecca; Parsons, Camille; Demoulin, Christophe; Rizzoli, René; Biver, Emmanuel; Dennison, Elaine; Bruyere, Olivier; Cooper, Cyrus

    2017-03-01

    the first quality of life questionnaire specific to sarcopenia, the SarQoL®, has recently been developed and validated in French. To extend the availability and utilisation of this questionnaire, its translation and validation in other languages is necessary. the purpose of this study was therefore to translate the SarQoL® into English and validate the psychometric properties of this new version. cross-sectional. Hertfordshire, UK. in total, 404 participants of the Hertfordshire Cohort Study, UK. the translation part was articulated in five stages: (i) two initial translations from French to English; (ii) synthesis of the two translations; (iii) backward translations; (iv) expert committee to compare the backward translations with the original questionnaire and (v) pre-test. To validate the English SarQoL®, we assessed its validity (discriminative power, construct validity), reliability (internal consistency, test-retest reliability) and floor/ceiling effects. the SarQoL® questionnaire was translated without any major difficulties. Results indicated a good discriminative power (lower score of quality of life for sarcopenic subjects, P = 0.01), high internal consistency (Cronbach's alpha of 0.88), consistent construct validity (high correlations found with domains related to mobility, usual activities, vitality, physical function and low correlations with domains related to anxiety, self-care, mental health and social problems) and excellent test-retest reliability (intraclass coefficient correlation of 0.95, 95%CI 0.92-0.97). Moreover, no floor/ceiling has been found. a valid SarQoL® English questionnaire is now available and can be used with confidence to better assess the disease burden associated with sarcopenia. It could also be used as a treatment outcome indicator in research. © The Author 2016. Published by Oxford University Press on behalf of the British Geriatrics Society.

  3. Automated Axon Counting in Rodent Optic Nerve Sections with AxonJ.

    PubMed

    Zarei, Kasra; Scheetz, Todd E; Christopher, Mark; Miller, Kathy; Hedberg-Buenz, Adam; Tandon, Anamika; Anderson, Michael G; Fingert, John H; Abràmoff, Michael David

    2016-05-26

    We have developed a publicly available tool, AxonJ, which quantifies the axons in optic nerve sections of rodents stained with paraphenylenediamine (PPD). In this study, we compare AxonJ's performance to human experts on 100x and 40x images of optic nerve sections obtained from multiple strains of mice, including mice with defects relevant to glaucoma. AxonJ produced reliable axon counts with high sensitivity of 0.959 and high precision of 0.907, high repeatability of 0.95 when compared to a gold-standard of manual assessments and high correlation of 0.882 to the glaucoma damage staging of a previously published dataset. AxonJ allows analyses that are quantitative, consistent, fully-automated, parameter-free, and rapid on whole optic nerve sections at 40x. As a freely available ImageJ plugin that requires no highly specialized equipment to utilize, AxonJ represents a powerful new community resource augmenting studies of the optic nerve using mice.

  4. Automated Axon Counting in Rodent Optic Nerve Sections with AxonJ

    NASA Astrophysics Data System (ADS)

    Zarei, Kasra; Scheetz, Todd E.; Christopher, Mark; Miller, Kathy; Hedberg-Buenz, Adam; Tandon, Anamika; Anderson, Michael G.; Fingert, John H.; Abràmoff, Michael David

    2016-05-01

    We have developed a publicly available tool, AxonJ, which quantifies the axons in optic nerve sections of rodents stained with paraphenylenediamine (PPD). In this study, we compare AxonJ’s performance to human experts on 100x and 40x images of optic nerve sections obtained from multiple strains of mice, including mice with defects relevant to glaucoma. AxonJ produced reliable axon counts with high sensitivity of 0.959 and high precision of 0.907, high repeatability of 0.95 when compared to a gold-standard of manual assessments and high correlation of 0.882 to the glaucoma damage staging of a previously published dataset. AxonJ allows analyses that are quantitative, consistent, fully-automated, parameter-free, and rapid on whole optic nerve sections at 40x. As a freely available ImageJ plugin that requires no highly specialized equipment to utilize, AxonJ represents a powerful new community resource augmenting studies of the optic nerve using mice.

  5. Reliability of the Test of Integrated Language and Literacy Skills (TILLS)

    ERIC Educational Resources Information Center

    Mailend, Marja-Liisa; Plante, Elena; Anderson, Michele A.; Applegate, E. Brooks; Nelson, Nickola W.

    2016-01-01

    Background: As new standardized tests become commercially available, it is critical that clinicians have access to the information about a test's psychometric properties, including aspects of reliability. Aims: The purpose of the three studies reported in this article was to investigate the reliability of a new test, the Test of Integrated…

  6. Large Sample Confidence Intervals for Item Response Theory Reliability Coefficients

    ERIC Educational Resources Information Center

    Andersson, Björn; Xin, Tao

    2018-01-01

    In applications of item response theory (IRT), an estimate of the reliability of the ability estimates or sum scores is often reported. However, analytical expressions for the standard errors of the estimators of the reliability coefficients are not available in the literature and therefore the variability associated with the estimated reliability…

  7. Investigating Postgraduate College Admission Interviews: Generalizability Theory Reliability and Incremental Predictive Validity

    ERIC Educational Resources Information Center

    Arce-Ferrer, Alvaro J.; Castillo, Irene Borges

    2007-01-01

    The use of face-to-face interviews is controversial for college admissions decisions in light of the lack of availability of validity and reliability evidence for most college admission processes. This study investigated reliability and incremental predictive validity of a face-to-face postgraduate college admission interview with a sample of…

  8. An electronic nose for reliable measurement and correct classification of beverages.

    PubMed

    Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A

    2011-01-01

    This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results.

  9. Turbomachine Sealing and Secondary Flows - Part 3. Part 3; Review of Power-Stream Support, Unsteady Flow Systems, Seal and Disk Cavity Flows, Engine Externals, and Life and Reliability Issues

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Steinetz, B. M.; Zaretsky, E. V.; Athavale, M. M.; Przekwas, A. J.

    2004-01-01

    The issues and components supporting the engine power stream are reviewed. It is essential that companies pay close attention to engine sealing issues, particularly on the high-pressure spool or high-pressure pumps. Small changes in these systems are reflected throughout the entire engine. Although cavity, platform, and tip sealing are complex and have a significant effect on component and engine performance, computational tools (e.g., NASA-developed INDSEAL, SCISEAL, and ADPAC) are available to help guide the designer and the experimenter. Gas turbine engine and rocket engine externals must all function efficiently with a high degree of reliability in order for the engine to run but often receive little attention until they malfunction. Within the open literature statistically significant data for critical engine components are virtually nonexistent; the classic approach is deterministic. Studies show that variations with loading can have a significant effect on component performance and life. Without validation data they are just studies. These variations and deficits in statistical databases require immediate attention.

  10. An Electronic Nose for Reliable Measurement and Correct Classification of Beverages

    PubMed Central

    Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A.

    2011-01-01

    This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results. PMID:22163964

  11. Size–strain separation in diffraction line profile analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scardi, P.; Ermrich, M.; Fitch, A.

    Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size–strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensitymore » values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.« less

  12. Size–strain separation in diffraction line profile analysis

    DOE PAGES

    Scardi, P.; Ermrich, M.; Fitch, A.; ...

    2018-05-29

    Separation of size and strain effects on diffraction line profiles has been studied in a round robin involving laboratory instruments and synchrotron radiation beamlines operating with different radiation, optics, detectors and experimental configurations. The studied sample, an extensively ball milled iron alloy powder, provides an ideal test case, as domain size broadening and strain broadening are of comparable size. The high energy available at some synchrotron radiation beamlines provides the best conditions for an accurate analysis of the line profiles, as the size–strain separation clearly benefits from a large number of Bragg peaks in the pattern; high counts, reliable intensitymore » values in low-absorption conditions, smooth background and data collection at different temperatures also support the possibility to include diffuse scattering in the analysis, for the most reliable assessment of the line broadening effect. However, results of the round robin show that good quality information on domain size distribution and microstrain can also be obtained using standard laboratory equipment, even when patterns include relatively few Bragg peaks, provided that the data are of good quality in terms of high counts and low and smooth background.« less

  13. A systematic review of psychometric testing of instruments that measure intention to work with older people.

    PubMed

    Che, Chong Chin; Hairi, Noran Naqiah; Chong, Mei Chan

    2017-09-01

    To review systematically the psychometric properties of instruments used to measure intention to work with older people. Nursing students are part of the future healthcare workforce; thus, being aware of their intention to work with older people would give valuable insights to nursing education and practice. Despite a plethora of research on measuring intention to work with older people, a valid and reliable instrument has not been identified. A systematic literature review of evidence and psychometric properties. Eight database searches were conducted between 2006 - 2016. English articles were selected based on inclusion and exclusion criteria. The COSMIN checklist was used to assess instruments reporting a psychometric evaluation of validity and reliability. Of 41 studies identified for full text review, 36 met the inclusion criteria. Seven different types of instruments were identified for psychometric evaluation. Measures of reliability were reported in eight papers and validity in five papers. Evidence for each measurement property was limited, with each instrument demonstrating a lack of information on measurement properties. Based on the COSMIN checklist, the overall quality of the psychometric properties was rated as poor to good. No single instrument was found to be optimal for use. Studies of high methodological quality are needed to properly assess the measurement properties of the instruments that are currently available. Until such studies are available, we recommend using existing instruments with caution. © 2017 John Wiley & Sons Ltd.

  14. 7 CFR 760.812 - Production losses; participant responsibility.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... required, the best verifiable or reliable production records available for the crop; (2) Summarizing all.... (c) In determining production under this section, the participant must supply verifiable or reliable...

  15. Applicability and Limitations of Reliability Allocation Methods

    NASA Technical Reports Server (NTRS)

    Cruz, Jose A.

    2016-01-01

    Reliability allocation process may be described as the process of assigning reliability requirements to individual components within a system to attain the specified system reliability. For large systems, the allocation process is often performed at different stages of system design. The allocation process often begins at the conceptual stage. As the system design develops, more information about components and the operating environment becomes available, different allocation methods can be considered. Reliability allocation methods are usually divided into two categories: weighting factors and optimal reliability allocation. When properly applied, these methods can produce reasonable approximations. Reliability allocation techniques have limitations and implied assumptions that need to be understood by system engineers. Applying reliability allocation techniques without understanding their limitations and assumptions can produce unrealistic results. This report addresses weighting factors, optimal reliability allocation techniques, and identifies the applicability and limitations of each reliability allocation technique.

  16. State-of-the-Art for Small Satellite Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Parker, Khary I.

    2016-01-01

    The NASA/Goddard Space Flight Center (NASA/GSFC) is in the business of performing world-class, space-based, scientific research on various spacecraft platforms, which now include small satellites (SmallSats). In order to perform world class science on a SmallSat, NASA/GSFC requires that their components be highly reliable, high performing, have low power consumption, at the lowest cost possible. The Propulsion Branch (Code 597) at NASA/GSFC has conducted a SmallSat propulsion system survey to determine their availability and level of development. Based on publicly available information and unique features, this paper discusses some of the existing SmallSat propulsion systems.. The systems described in this paper do not indicate or imply any endorsement by NASA or NASA/GSFC over those not included.

  17. Creating Highly Reliable Accountable Care Organizations.

    PubMed

    Vogus, Timothy J; Singer, Sara J

    2016-12-01

    Accountable Care Organizations' (ACOs) pursuit of the triple aim of higher quality, lower cost, and improved population health has met with mixed results. To improve the design and implementation of ACOs we look to organizations that manage similarly complex, dynamic, and tightly coupled conditions while sustaining exceptional performance known as high-reliability organizations. We describe the key processes through which organizations achieve reliability, the leadership and organizational practices that enable it, and the role that professionals can play when charged with enacting it. Specifically, we present concrete practices and processes from health care organizations pursuing high-reliability and from early ACOs to illustrate how the triple aim may be met by cultivating mindful organizing, practicing reliability-enhancing leadership, and identifying and supporting reliability professionals. We conclude by proposing a set of research questions to advance the study of ACOs and high-reliability research. © The Author(s) 2016.

  18. Verification of Triple Modular Redundancy Insertion for Reliable and Trusted Systems

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Kenneth

    2016-01-01

    If a system is required to be protected using triple modular redundancy (TMR), improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process and the complexity of digital designs, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems.

  19. Evaluation of potential emission spectra for the reliable classification of fluorescently coded materials

    NASA Astrophysics Data System (ADS)

    Brunner, Siegfried; Kargel, Christian

    2011-06-01

    The conservation and efficient use of natural and especially strategic resources like oil and water have become global issues, which increasingly initiate environmental and political activities for comprehensive recycling programs. To effectively reutilize oil-based materials necessary in many industrial fields (e.g. chemical and pharmaceutical industry, automotive, packaging), appropriate methods for a fast and highly reliable automated material identification are required. One non-contacting, color- and shape-independent new technique that eliminates the shortcomings of existing methods is to label materials like plastics with certain combinations of fluorescent markers ("optical codes", "optical fingerprints") incorporated during manufacture. Since time-resolved measurements are complex (and expensive), fluorescent markers must be designed that possess unique spectral signatures. The number of identifiable materials increases with the number of fluorescent markers that can be reliably distinguished within the limited wavelength band available. In this article we shall investigate the reliable detection and classification of fluorescent markers with specific fluorescence emission spectra. These simulated spectra are modeled based on realistic fluorescence spectra acquired from material samples using a modern VNIR spectral imaging system. In order to maximize the number of materials that can be reliably identified, we evaluate the performance of 8 classification algorithms based on different spectral similarity measures. The results help guide the design of appropriate fluorescent markers, optical sensors and the overall measurement system.

  20. Establishing the validity and reliability of the Project Talent Personality Inventory

    PubMed Central

    Pozzebon, Julie; Damian, Rodica I.; Hill, Patrick L.; Lin, Yuchen; Lapham, Susan; Roberts, Brent W.

    2013-01-01

    Project Talent is a national longitudinal study that started in 1960. The original sample included over 440,000 students, which amounted to a 5% representative sample of high school students across the United States. Previous research has not yet established the validity and reliability of the personality measure used in this study, that is, the Project Talent Personality Inventory (PTPI). Given the potential interest and use of the PTPI in forthcoming research, the goals of the present paper were to establish (a) the construct and predictive validity and (b) the internal consistency and test-retest reliability of the PTPI. This information will be valuable to researchers who might be interested in using the PTPI to predict life course outcomes, such as mortality, occupational success, relationship success, and health. Study 1 found that the 10 sub-scales of the PTPI showed good internal consistency reliability, as well as good construct and predictive validity. With the use of several modern personality measures, we showed how the 10 PTPI scales can be mapped onto the Big Five personality traits, and we examined their relations with health, well-being, and life satisfaction outcomes. Study 2 found that the 10 PTPI scales showed good test-retest reliability. Together, these findings allow researchers to better understand and use the PTPI scales, as they are available in Project Talent. PMID:24399984

  1. A new communication protocol family for a distributed spacecraft control system

    NASA Technical Reports Server (NTRS)

    Baldi, Andrea; Pace, Marco

    1994-01-01

    In this paper we describe the concepts behind and architecture of a communication protocol family, which was designed to fulfill the communication requirements of ESOC's new distributed spacecraft control system SCOS 2. A distributed spacecraft control system needs a data delivery subsystem to be used for telemetry (TLM) distribution, telecommand (TLC) dispatch and inter-application communication, characterized by the following properties: reliability, so that any operational workstation is guaranteed to receive the data it needs to accomplish its role; efficiency, so that the telemetry distribution, even for missions with high telemetry rates, does not cause a degradation of the overall control system performance; scalability, so that the network is not the bottleneck both in terms of bandwidth and reconfiguration; flexibility, so that it can be efficiently used in many different situations. The new protocol family which satisfies the above requirements is built on top of widely used communication protocols (UDP and TCP), provides reliable point-to-point and broadcast communication (UDP+) and is implemented in C++. Reliability is achieved using a retransmission mechanism based on a sequence numbering scheme. Such a scheme allows to have cost-effective performances compared to the traditional protocols, because retransmission is only triggered by applications which explicitly need reliability. This flexibility enables applications with different profiles to take advantage of the available protocols, so that the best rate between sped and reliability can be achieved case by case.

  2. The poor quality and reliability of information on periacetabular osteotomy on the internet in Japan

    PubMed Central

    Takegami, Yasuhiko; Seki, Taisuke; Amano, Takafumi; Higuchi, Yoshitoshi; Komatsu, Daigo; Nishida, Yoshihiro; Ishiguro, Naoki

    2017-01-01

    ABSTRACT Although many patients use the internet to access health-related information, the quality and the reliability of the information is highly inconsistent. Periacetabular osteotomy (PAO) is one of the surgical procedures for hip dysplasia. However, medical information on PAO is limited on the internet. This study aims to evaluate the quality and reliability of information available on PAO on the internet in Japan. A web search was conducted on two search engines for the following terms: “hip osteotomy,” “pelvic osteotomy,” and “osteotomy for hip preservation” in Japanese. In total, we found 120 websites. To determine the quality and reliability of information on each website, we used the Health on the Net Foundation (HON) score, the Brief DISCERN score, and an osteotomy-specific content (OSC) score. After eliminating duplicate websites, we reviewed 49 unique websites. Only three websites (6.1%) had good reliability, as indicated by their HON scores. Twelve websites (24.4%) had good-quality information, as measured by their Brief DISCERN scores. As evaluated by their OSC scores, physician websites were found to be biased toward etiology and surgical indication and did not provide information on the complications of procedures. Non-physician websites were generally insufficient. The information about PAO on the internet is, therefore, unreliable and of poor-quality for Japanese patients. PMID:28878442

  3. Shear-wave sonoelastography for assessing masseter muscle hardness in comparison with strain sonoelastography: study with phantoms and healthy volunteers

    PubMed Central

    Nakayama, Miwa; Nishiyama, Wataru; Nozawa, Michihito

    2016-01-01

    Objectives Shear-wave sonoelastography is expected to facilitate low operator dependency, high reproducibility and quantitative evaluation, whereas there are few reports on available normative values of in vivo tissue in head and neck fields. The purpose of this study was to examine the reliabilities on measuring hardness using shear-wave sonoelastography and to clarify normal values of masseter muscle hardness in healthy volunteers. Methods Phantoms with known hardness ranging from 20 to 140 kPa were scanned with shear-wave sonoelastography, and inter- and intraoperator reliabilities were examined compared with strain sonoelastography. The relationships between the actual and measured hardness were analyzed. The masseter muscle hardness in 30 healthy volunteers was measured using shear-wave sonoelastography. Results: The inter- and intraoperator intraclass correlation coefficients were almost perfect. Strong correlations were seen between the actual and measured hardness. The mean hardness of the masseter muscles in healthy volunteers was 42.82 ± 5.56 kPa at rest and 53.36 ± 8.46 kPa during jaw clenching. Conclusions: The hardness measured with shear-wave sonoelastography showed high-level reliability. Shear-wave sonoelastography may be suitable for evaluation of the masseter muscles. PMID:26624000

  4. Shear-wave sonoelastography for assessing masseter muscle hardness in comparison with strain sonoelastography: study with phantoms and healthy volunteers.

    PubMed

    Ariji, Yoshiko; Nakayama, Miwa; Nishiyama, Wataru; Nozawa, Michihito; Ariji, Eiichiro

    2016-01-01

    Objectives Shear-wave sonoelastography is expected to facilitate low operator dependency, high reproducibility and quantitative evaluation, whereas there are few reports on available normative values of in vivo tissue in head and neck fields. The purpose of this study was to examine the reliabilities on measuring hardness using shear-wave sonoelastography and to clarify normal values of masseter muscle hardness in healthy volunteers. Methods Phantoms with known hardness ranging from 20 to 140 kPa were scanned with shear-wave sonoelastography, and inter- and intraoperator reliabilities were examined compared with strain sonoelastography. The relationships between the actual and measured hardness were analyzed. The masseter muscle hardness in 30 healthy volunteers was measured using shear-wave sonoelastography. The inter- and intraoperator intraclass correlation coefficients were almost perfect. Strong correlations were seen between the actual and measured hardness. The mean hardness of the masseter muscles in healthy volunteers was 42.82 ± 5.56 kPa at rest and 53.36 ± 8.46 kPa during jaw clenching. The hardness measured with shear-wave sonoelastography showed high-level reliability. Shear-wave sonoelastography may be suitable for evaluation of the masseter muscles.

  5. Impact of Co-Site Interference on L/C-Band Spectrum for UAS Control and Non-Payload Communications

    NASA Technical Reports Server (NTRS)

    Kerczewski, Robert J.; Bishop, William D.; Hoder, Douglas J.; Shalkhauser, Kurt A.; Wilson, Jeffrey D.

    2015-01-01

    In order to provide for the safe integration of unmanned aircraft systems into the National Airspace System, the control and non-payload communications (CNPC) link connecting the ground-based pilot with the unmanned aircraft must be highly reliable. A specific requirement is that it must operate using aviation safety radiofrequency spectrum. The 2012 World Radiocommunication Conference (WRC-12) provided a potentially suitable allocation for LOS CNPC spectrum in C-Band at 5030-5091 MHz band which, when combined with a previous allocation in L-Band (960-1164 MHz) may satisfy the LOS spectrum requirement and provide for high reliability through dual-band redundancy. However, the LBand spectrum hosts a number of aeronautical navigation systems which require high-power transmitters on-board the aircraft. These high-power transmitters co-located with sensitive CNPC receivers operating in the same frequency band have the potential to create co-site interference, reducing the performance of the CNPC receivers and ultimately reducing the usability of the L-Band for CNPC. This paper examines the potential for co-site interference, as highlighted in recent flight tests, and discusses the impact on the UAS CNPC spectrum availability and requirements for further testing and analysis.

  6. Reliability of the Melbourne assessment of unilateral upper limb function.

    PubMed

    Randall, M; Carlin, J B; Chondros, P; Reddihough, D

    2001-11-01

    This study examines the reliability of the Melbourne Assessment of Unilateral Upper Limb Function: a quantitative test of quality of movement in children with neurological impairment. The assessment was administered to 20 children aged from 5 to 16 years (mean age 9 years 10 months, SD 2 years 10 months) who had various types and degrees of cerebral palsy (CP). The performances of the 20 children during assessment were videotaped for subsequent scoring by 15 occupational therapists. Scores were analyzed for internal consistency of test items, inter- and intrarater reliability of scorings of the same videotapes, and test-retest reliability using repeat videotaping. Results revealed very high internal consistency of test items (alpha=0.96), moderate to high agreement both within and between raters for all test items (intraclass correlations of at least 0.7) apart from item 16 (hand to mouth and down), and high interrater reliability (0.95) and intrarater reliability (0.97) for total test scores. Test-retest results revealed moderate to high intrarater reliability for item totals (mean of 0.83 and 0.79) for each rater and high reliability for test totals (0.98 and 0.97). These findings indicate that the Melbourne Assessment of Unilateral Upper Limb Function is a reliable tool for measuring the quality of unilateral upper-limb movement in children with CP.

  7. Analysis of fatigue reliability for high temperature and high pressure multi-stage decompression control valve

    NASA Astrophysics Data System (ADS)

    Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang

    2018-03-01

    Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.

  8. A Database for Comparative Electrochemical Performance of Commercial 18650-Format Lithium-Ion Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barkholtz, Heather M.; Fresquez, Armando; Chalamala, Babu R.

    Lithium-ion batteries are a central technology to our daily lives with widespread use in mobile devices and electric vehicles. These batteries are also beginning to be widely used in electric grid infrastructure support applications which have stringent safety and reliability requirements. Typically, electrochemical performance data is not available for modelers to validate their simulations, mechanisms, and algorithms for lithium-ion battery performance and lifetime. In this paper, we report on the electrochemical performance of commercial 18650 cells at a variety of temperatures and discharge currents. We found that LiFePO 4 is temperature tolerant for discharge currents at or below 10 Amore » whereas LiCoO 2, LiNi xCo yAl 1-x-yO 2, and LiNi 0.80Mn 0.15Co 0.05O 2 exhibited optimal electrochemical performance when the temperature is maintained at 15°C. LiNi xCo yAl 1-x-yO 2 showed signs of lithium plating at lower temperatures, evidenced by irreversible capacity loss and emergence of a high-voltage differential capacity peak. Furthermore, all cells need to be monitored for self-heating, as environment temperature and high discharge currents may elicit an unintended abuse condition. Overall, this study shows that lithium-ion batteries are highly application-specific and electrochemical behavior must be well understood for safe and reliable operation. Additionally, data collected in this study is available for anyone to download for further analysis and model validation.« less

  9. A Database for Comparative Electrochemical Performance of Commercial 18650-Format Lithium-Ion Cells

    DOE PAGES

    Barkholtz, Heather M.; Fresquez, Armando; Chalamala, Babu R.; ...

    2017-09-08

    Lithium-ion batteries are a central technology to our daily lives with widespread use in mobile devices and electric vehicles. These batteries are also beginning to be widely used in electric grid infrastructure support applications which have stringent safety and reliability requirements. Typically, electrochemical performance data is not available for modelers to validate their simulations, mechanisms, and algorithms for lithium-ion battery performance and lifetime. In this paper, we report on the electrochemical performance of commercial 18650 cells at a variety of temperatures and discharge currents. We found that LiFePO 4 is temperature tolerant for discharge currents at or below 10 Amore » whereas LiCoO 2, LiNi xCo yAl 1-x-yO 2, and LiNi 0.80Mn 0.15Co 0.05O 2 exhibited optimal electrochemical performance when the temperature is maintained at 15°C. LiNi xCo yAl 1-x-yO 2 showed signs of lithium plating at lower temperatures, evidenced by irreversible capacity loss and emergence of a high-voltage differential capacity peak. Furthermore, all cells need to be monitored for self-heating, as environment temperature and high discharge currents may elicit an unintended abuse condition. Overall, this study shows that lithium-ion batteries are highly application-specific and electrochemical behavior must be well understood for safe and reliable operation. Additionally, data collected in this study is available for anyone to download for further analysis and model validation.« less

  10. Organize to manage reliability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricketts, R.

    An analysis of maintenance costs in hydrocarbon processing industry (HPI) plants has revealed that attitudes and practices of personnel are the major single bottom line factor. In reaching this conclusion, Solomon Associates examined comparative analysis of plant records over the past decade. The authors learned that there was a wide range of performance independent of refinery age, capacity, processing complexity, and location. Facilities of all extremes in these attributes are included in both high-cost and low-cost categories. Those in the lowest quartile of performance posted twice the resource consumption as the best quartile. Furthermore, there was almost no similarity betweenmore » refineries within a single company. The paper discusses cost versus availability, maintenance spending, two organizational approaches used (repair focused and reliability focused), and organizational style and structure.« less

  11. pp interaction at very high energies in cosmic ray experiments

    NASA Astrophysics Data System (ADS)

    Kendi Kohara, A.; Ferreira, Erasmo; Kodama, Takeshi

    2014-11-01

    An analysis of p-air cross section data from extensive air shower measurements is presented, based on an analytical representation of the pp scattering amplitudes that describes with high precision all available accelerator data at ISR, SPS and LHC energies. The theoretical basis of the representation, together with the very smooth energy dependence of parameters controlled by unitarity and dispersion relations, permits reliable extrapolation to high energy cosmic ray (CR) and asymptotic energy ranges. Calculations of σ p-airprod based on Glauber formalism are made using the input values of the quantities σ , ρ , BI and BR at high energies, with attention given to the independence of the slope parameters, with {{B}R}\

  12. Network survivability performance (computer diskette)

    NASA Astrophysics Data System (ADS)

    1993-11-01

    File characteristics: Data file; 1 file. Physical description: 1 computer diskette; 3 1/2 in.; high density; 2.0MB. System requirements: Mac; Word. This technical report has been developed to address the survivability of telecommunications networks including services. It responds to the need for a common understanding of, and assessment techniques for network survivability, availability, integrity, and reliability. It provides a basis for designing and operating telecommunication networks to user expectations for network survivability.

  13. Development and reliability testing of a food store observation form.

    PubMed

    Rimkus, Leah; Powell, Lisa M; Zenk, Shannon N; Han, Euna; Ohri-Vachaspati, Punam; Pugach, Oksana; Barker, Dianne C; Resnick, Elissa A; Quinn, Christopher M; Myllyluoma, Jaana; Chaloupka, Frank J

    2013-01-01

    To develop a reliable food store observational data collection instrument to be used for measuring product availability, pricing, and promotion. Observational data collection. A total of 120 food stores (26 supermarkets, 34 grocery stores, 54 gas/convenience stores, and 6 mass merchandise stores) in the Chicago metropolitan statistical area. Inter-rater reliability for product availability, pricing, and promotion measures on a food store observational data collection instrument. Cohen's kappa coefficient and proportion of overall agreement for dichotomous variables and intra-class correlation coefficient for continuous variables. Inter-rater reliability, as measured by average kappa coefficient, was 0.84 for food and beverage product availability measures, 0.80 for interior store characteristics, and 0.70 for exterior store characteristics. For continuous measures, average intra-class correlation coefficient was 0.82 for product pricing measures; 0.90 for counts of fresh, frozen, and canned fruit and vegetable options; and 0.85 for counts of advertisements on the store exterior and property. The vast majority of measures demonstrated substantial or almost perfect agreement. Although some items may require revision, results suggest that the instrument may be used to reliably measure the food store environment. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  14. Big data analytics for the Future Circular Collider reliability and availability studies

    NASA Astrophysics Data System (ADS)

    Begy, Volodimir; Apollonio, Andrea; Gutleber, Johannes; Martin-Marquez, Manuel; Niemi, Arto; Penttinen, Jussi-Pekka; Rogova, Elena; Romero-Marin, Antonio; Sollander, Peter

    2017-10-01

    Responding to the European Strategy for Particle Physics update 2013, the Future Circular Collider study explores scenarios of circular frontier colliders for the post-LHC era. One branch of the study assesses industrial approaches to model and simulate the reliability and availability of the entire particle collider complex based on the continuous monitoring of CERN’s accelerator complex operation. The modelling is based on an in-depth study of the CERN injector chain and LHC, and is carried out as a cooperative effort with the HL-LHC project. The work so far has revealed that a major challenge is obtaining accelerator monitoring and operational data with sufficient quality, to automate the data quality annotation and calculation of reliability distribution functions for systems, subsystems and components where needed. A flexible data management and analytics environment that permits integrating the heterogeneous data sources, the domain-specific data quality management algorithms and the reliability modelling and simulation suite is a key enabler to complete this accelerator operation study. This paper describes the Big Data infrastructure and analytics ecosystem that has been put in operation at CERN, serving as the foundation on which reliability and availability analysis and simulations can be built. This contribution focuses on data infrastructure and data management aspects and presents case studies chosen for its validation.

  15. Online patient information on Vagus Nerve Stimulation: How reliable is it for facilitating shared decision making?

    PubMed

    Ved, Ronak; Cobbold, Naomi; Igbagiri, Kueni; Willis, Mark; Leach, Paul; Zaben, Malik

    2017-08-01

    This study evaluates the quality of information available on the internet for carers of children with epilepsy considering treatment with Vagus Nerve Stimulation (VNS). Selected key phrases were entered into two popular search engines (Google™, Yahoo™). These phrases were: "Vagus nerve stimulator", alone and in combination with "childhood epilepsy", "paediatric epilepsy" and "epilepsy in childhood"; "VNS", and "VNS epilepsy". The first 50 hits per search were then screened. Of 600 identified sites, duplicated (262), irrelevant (230) and inaccessible (15) results were excluded. 93 websites were identified for evaluation using the DISCERN instrument, an online validation tool for patient information websites. The mean DISCERN score of all analysed websites was 39/80 (49%; SD 13.5). This equates to Fair to borderline Poor global quality, (Excellent=80-63; Good=62-51; Fair=50-39; Poor=38-27; Very poor=26-15). None of the analysed sites obtained an Excellent quality rating. 13% (12) obtained a Good score, 40% (37) obtained an Average score, 35% (33) obtained a Poor score, and 12% (11) obtained a Very poor score. The cohort of websites scored particularly poorly on assessment of whether reliable, holistic information was presented, for instance provision of reliable sources, (28%, SD 18) and discussion of alternative treatments, (30%, SD 14). To facilitate patient-centred shared decision-making, high quality information needs to be available for patients and families considering VNS. This study identifies that such information is difficult to locate on the internet. There is a need to develop focussed and reliable online patient resources for VNS. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  16. Electronic synoptic operative reporting: assessing the reliability and completeness of synoptic reports for pancreatic resection.

    PubMed

    Park, Jason; Pillarisetty, Venu G; Brennan, Murray F; Jarnagin, William R; D'Angelica, Michael I; Dematteo, Ronald P; G Coit, Daniel; Janakos, Maria; Allen, Peter J

    2010-09-01

    Electronic synoptic operative reports (E-SORs) have replaced dictated reports at many institutions, but whether E-SORs adequately document the components and findings of an operation has received limited study. This study assessed the reliability and completeness of E-SORs for pancreatic surgery developed at our institution. An attending surgeon and surgical fellow prospectively and independently completed an E-SOR after each of 112 major pancreatic resections (78 proximal, 29 distal, and 5 central) over a 10-month period (September 2008 to June 2009). Reliability was assessed by calculating the interobserver agreement between attending physician and fellow reports. Completeness was assessed by comparing E-SORs to a case-matched (surgeon and procedure) historical control of dictated reports, using a 39-item checklist developed through an internal and external query of 13 high-volume pancreatic surgeons. Interobserver agreement between attending and fellow was moderate to very good for individual categorical E-SOR items (kappa = 0.65 to 1.00, p < 0.001 for all items). Compared with dictated reports, E-SORs had significantly higher completeness checklist scores (mean 88.8 +/- 5.4 vs 59.6 +/- 9.2 [maximum possible score, 100], p < 0.01) and were available in patients' electronic records in a significantly shorter interval of time (median 0.5 vs 5.8 days from case end, p < 0.01). The mean time taken to complete E-SORs was 4.0 +/- 1.6 minutes per case. E-SORs for pancreatic surgery are reliable, complete in data collected, and rapidly available, all of which support their clinical implementation. The inherent strengths of E-SORs offer real promise of a new standard for operative reporting and health communication. Copyright 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Reliability and accuracy of four dental shade-matching devices.

    PubMed

    Kim-Pusateri, Seungyee; Brewer, Jane D; Davis, Elaine L; Wee, Alvin G

    2009-03-01

    There are several electronic shade-matching instruments available for clinical use, but the reliability and accuracy of these instruments have not been thoroughly investigated. The purpose of this in vitro study was to evaluate the reliability and accuracy of 4 dental shade-matching instruments in a standardized environment. Four shade-matching devices were tested: SpectroShade, ShadeVision, VITA Easyshade, and ShadeScan. Color measurements were made of 3 commercial shade guides (Vitapan Classical, Vitapan 3D-Master, and Chromascop). Shade tabs were placed in the middle of a gingival matrix (Shofu GUMY) with shade tabs of the same nominal shade from additional shade guides placed on both sides. Measurements were made of the central region of the shade tab positioned inside a black box. For the reliability assessment, each shade tab from each of the 3 shade guide types was measured 10 times. For the accuracy assessment, each shade tab from 10 guides of each of the 3 types evaluated was measured once. Differences in reliability and accuracy were evaluated using the Standard Normal z test (2 sided) (alpha=.05) with Bonferroni correction. Reliability of devices was as follows: ShadeVision, 99.0%; SpectroShade, 96.9%; VITA Easyshade, 96.4%; and ShadeScan, 87.4%. A significant difference in reliability was found between ShadeVision and ShadeScan (P=.008). All other comparisons showed similar reliability. Accuracy of devices was as follows: VITA Easyshade, 92.6%; ShadeVision, 84.8%; SpectroShade, 80.2%; and ShadeScan, 66.8%. Significant differences in accuracy were found between all device pairs (P<.001) for all comparisons except for SpectroShade versus ShadeVision (P=.033). Most devices had similar high reliability (over 96%), indicating predictable shade values from repeated measurements. However, there was more variability in accuracy among devices (67-93%), and differences in accuracy were seen with most device comparisons.

  18. Reliability and Maintainability Engineering - A Major Driver for Safety and Affordability

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.

    2011-01-01

    The United States National Aeronautics and Space Administration (NASA) is in the midst of an effort to design and build a safe and affordable heavy lift vehicle to go to the moon and beyond. To achieve that, NASA is seeking more innovative and efficient approaches to reduce cost while maintaining an acceptable level of safety and mission success. One area that has the potential to contribute significantly to achieving NASA safety and affordability goals is Reliability and Maintainability (R&M) engineering. Inadequate reliability or failure of critical safety items may directly jeopardize the safety of the user(s) and result in a loss of life. Inadequate reliability of equipment may directly jeopardize mission success. Systems designed to be more reliable (fewer failures) and maintainable (fewer resources needed) can lower the total life cycle cost. The Department of Defense (DOD) and industry experience has shown that optimized and adequate levels of R&M are critical for achieving a high level of safety and mission success, and low sustainment cost. Also, lessons learned from the Space Shuttle program clearly demonstrated the importance of R&M engineering in designing and operating safe and affordable launch systems. The Challenger and Columbia accidents are examples of the severe impact of design unreliability and process induced failures on system safety and mission success. These accidents demonstrated the criticality of reliability engineering in understanding component failure mechanisms and integrated system failures across the system elements interfaces. Experience from the shuttle program also shows that insufficient Reliability, Maintainability, and Supportability (RMS) engineering analyses upfront in the design phase can significantly increase the sustainment cost and, thereby, the total life cycle cost. Emphasis on RMS during the design phase is critical for identifying the design features and characteristics needed for time efficient processing, improved operational availability, and optimized maintenance and logistic support infrastructure. This paper discusses the role of R&M in a program acquisition phase and the potential impact of R&M on safety, mission success, operational availability, and affordability. This includes discussion of the R&M elements that need to be addressed and the R&M analyses that need to be performed in order to support a safe and affordable system design. The paper also provides some lessons learned from the Space Shuttle program on the impact of R&M on safety and affordability.

  19. Wind energy Computerized Maintenance Management System (CMMS) : data collection recommendations for reliability analysis.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, Valerie A.; Ogilvie, Alistair B.

    2012-01-01

    This report addresses the general data requirements for reliability analysis of fielded wind turbines and other wind plant equipment. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific data recommendations for a Computerized Maintenance Management System (CMMS) to support automated analysis. This data collection recommendations report was written by Sandia National Laboratories to address the general data requirements for reliability analysis of operating wind turbines. This report is intended to help develop a basic understanding of the data needed for reliability analysis frommore » a Computerized Maintenance Management System (CMMS) and other data systems. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific recommendations for a CMMS to support automated analysis. Though written for reliability analysis of wind turbines, much of the information is applicable to a wider variety of equipment and analysis and reporting needs. The 'Motivation' section of this report provides a rationale for collecting and analyzing field data for reliability analysis. The benefits of this type of effort can include increased energy delivered, decreased operating costs, enhanced preventive maintenance schedules, solutions to issues with the largest payback, and identification of early failure indicators.« less

  20. Design of testbed and emulation tools

    NASA Technical Reports Server (NTRS)

    Lundstrom, S. F.; Flynn, M. J.

    1986-01-01

    The research summarized was concerned with the design of testbed and emulation tools suitable to assist in projecting, with reasonable accuracy, the expected performance of highly concurrent computing systems on large, complete applications. Such testbed and emulation tools are intended for the eventual use of those exploring new concurrent system architectures and organizations, either as users or as designers of such systems. While a range of alternatives was considered, a software based set of hierarchical tools was chosen to provide maximum flexibility, to ease in moving to new computers as technology improves and to take advantage of the inherent reliability and availability of commercially available computing systems.

  1. Percutaneous transhepatic cholangiography in the investigation of the persistent postoperative bile leak.

    PubMed

    Kissin, C M; Grundy, A

    1987-01-01

    Percutaneous transhepatic cholangiography (PTHC) is now a widely available, inexpensive investigation with a low incidence of complications, especially in the nonobstructed system, and a high success rate. Its role in the management of obstructive jaundice is well established but it is only infrequently performed in the investigation of persistent bile leakage following biliary tract surgery. Four cases are reported in which the superior demonstration of biliary anatomy provided by PTHC allowed successful identification of the site of postoperative biliary leakage. We compared PTHC with other diagnostic imaging techniques available and conclude that it is a safe, accurate, and reliable technique.

  2. Women fishing in Oceania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, M.D.

    1987-09-01

    Women's fishing in Oceania has been overlooked in most subsistence studies in the region and, as a consequence, there are few quantitative data available upon which to base an assessment of its importance. However, in the present study, the few data available on women's fishing in Oceania are examined, and these show that women contribute significantly to marine food yields in the region. Also, it is suggested that the highly regular nature of women's fishing makes women more reliable, and therefore more effective than men as suppliers of protein for subsistence. The implications of these findings for future development policiesmore » in the region are then discussed.« less

  3. Managing and monitoring tuberculosis using web-based tools in combination with traditional approaches

    PubMed Central

    Chapman, Ann LN; Darton, Thomas C; Foster, Rachel A

    2013-01-01

    Tuberculosis (TB) remains a global health emergency. Ongoing challenges include the coordination of national and international control programs, high levels of drug resistance in many parts of the world, and availability of accurate and rapid diagnostic tests. The increasing availability and reliability of Internet access throughout both affluent and resource-limited countries brings new opportunities to improve TB management and control through the integration of web-based technologies with traditional approaches. In this review, we explore current and potential future use of web-based tools in the areas of TB diagnosis, treatment, epidemiology, service monitoring, and teaching and training. PMID:24294008

  4. Reliability and Normative Data for the Dynamic Visual Acuity Test for Vestibular Screening.

    PubMed

    Riska, Kristal M; Hall, Courtney D

    2016-06-01

    The purpose of this study was to determine reliability of computerized dynamic visual acuity (DVA) testing and to determine reference values for younger and older adults. A primary function of the vestibular system is to maintain gaze stability during head motion. The DVA test quantifies gaze stabilization with the head moving versus stationary. Commercially available computerized systems allow clinicians to incorporate DVA into their assessment; however, information regarding reliability and normative values of these systems is sparse. Forty-six healthy adults, grouped by age, with normal vestibular function were recruited. Each participant completed computerized DVA testing including static visual acuity, minimum perception time, and DVA using the NeuroCom inVision System. Testing was performed by two examiners in the same session and then repeated at a follow-up session 3 to 14 days later. Intraclass correlation coefficients (ICCs) were used to determine inter-rater and test-retest reliability. ICCs for inter-rater reliability ranged from 0.323 to 0.937 and from 0.434 to 0.909 for horizontal and vertical head movements, respectively. ICCs for test-retest reliability ranged from 0.154 to 0.856 and from 0.377 to 0.9062 for horizontal and vertical head movements, respectively. Overall, raw scores (left/right DVA and up/down DVA) were more reliable than DVA loss scores. Reliability of a commercially available DVA system has poor-to-fair reliability for DVA loss scores. The use of a convergence paradigm and not incorporating the forced choice paradigm may contribute to poor reliability.

  5. COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies

    NASA Technical Reports Server (NTRS)

    Brusse, Jay A.; Sampson, Michael J.

    2004-01-01

    Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.

  6. Limitations of Reliability for Long-Endurance Human Spaceflight

    NASA Technical Reports Server (NTRS)

    Owens, Andrew C.; de Weck, Olivier L.

    2016-01-01

    Long-endurance human spaceflight - such as missions to Mars or its moons - will present a never-before-seen maintenance logistics challenge. Crews will be in space for longer and be farther way from Earth than ever before. Resupply and abort options will be heavily constrained, and will have timescales much longer than current and past experience. Spare parts and/or redundant systems will have to be included to reduce risk. However, the high cost of transportation means that this risk reduction must be achieved while also minimizing mass. The concept of increasing system and component reliability is commonly discussed as a means to reduce risk and mass by reducing the probability that components will fail during a mission. While increased reliability can reduce maintenance logistics mass requirements, the rate of mass reduction decreases over time. In addition, reliability growth requires increased test time and cost. This paper assesses trends in test time requirements, cost, and maintenance logistics mass savings as a function of increase in Mean Time Between Failures (MTBF) for some or all of the components in a system. In general, reliability growth results in superlinear growth in test time requirements, exponential growth in cost, and sublinear benefits (in terms of logistics mass saved). These trends indicate that it is unlikely that reliability growth alone will be a cost-effective approach to maintenance logistics mass reduction and risk mitigation for long-endurance missions. This paper discusses these trends as well as other options to reduce logistics mass such as direct reduction of part mass, commonality, or In-Space Manufacturing (ISM). Overall, it is likely that some combination of all available options - including reliability growth - will be required to reduce mass and mitigate risk for future deep space missions.

  7. A Persian-version of the stuttering severity instrument-version four (SSI-4): How the new additions to SSI-4 complement its stuttering severity score?

    PubMed

    Tahmasebi, Neda; Shafie, Bijan; Karimi, Hamid; Mazaheri, Masood

    The fourth version of the Stuttering Severity Instrument (SSI-4) has been available since 2009. It has some modifications and new features which make it more appropriate at least for clinical practice, although further documentation is needed. The objective of the current research was to translate SSI-4 into Persian language and to discuss its relative and absolute reliability as well as its criterion validity for Persian adults who stutter (PWS). We also aimed to study how the new subjective self-reports of the SSI-4 complement the stuttering severity score obtained from the SSI-3 or the SSI-4. The cross-cultural guideline recommended by the International Quality of Life Assessment project was used to translate the SSI-4 into Persian language. Thirty five PWS from ages 17 to 42 were recruited and 10 speech and language pathologists assessed their stuttering severity using either the SSI-4 or stuttering severity ratings (SR) to test validity and reliability of the Persian translated version. A very high inter-judge relative reliability along with a poor absolute inter-judge reliability was found for the SSI-4 scores. The results were more promising for the intra-judge absolute reliability. Test-retest reliability of the complementary questions to the SSI-4 was also found acceptable. However, no strong relationship was found between the SSI-4 scores and its complementary questions. The Persian version of the SSI-4 can be used reliably by trained SLPs for research and clinical purposes, but not to document small changes in stuttering severity. We argue that the response of participants to the complementary self-report questions should also be considered in calculating their stuttering severity score. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. The Stability and Validity of Automated Vocal Analysis in Preverbal Preschoolers With Autism Spectrum Disorder

    PubMed Central

    Woynaroski, Tiffany; Oller, D. Kimbrough; Keceli-Kaysili, Bahar; Xu, Dongxin; Richards, Jeffrey A.; Gilkerson, Jill; Gray, Sharmistha; Yoder, Paul

    2017-01-01

    Theory and research suggest that vocal development predicts “useful speech” in preschoolers with autism spectrum disorder (ASD), but conventional methods for measurement of vocal development are costly and time consuming. This longitudinal correlational study examines the reliability and validity of several automated indices of vocalization development relative to an index derived from human coded, conventional communication samples in a sample of preverbal preschoolers with ASD. Automated indices of vocal development were derived using software that is presently “in development” and/or only available for research purposes and using commercially available Language ENvironment Analysis (LENA) software. Indices of vocal development that could be derived using the software available for research purposes: (a) were highly stable with a single day-long audio recording, (b) predicted future spoken vocabulary to a degree that was nonsignificantly different from the index derived from conventional communication samples, and (c) continued to predict future spoken vocabulary even after controlling for concurrent vocabulary in our sample. The score derived from standard LENA software was similarly stable, but was not significantly correlated with future spoken vocabulary. Findings suggest that automated vocal analysis is a valid and reliable alternative to time intensive and expensive conventional communication samples for measurement of vocal development of preverbal preschoolers with ASD in research and clinical practice. PMID:27459107

  9. Materials Research Capabilities

    NASA Technical Reports Server (NTRS)

    Stofan, Andrew J.

    1986-01-01

    Lewis Research Center, in partnership with U.S. industry and academia, has long been a major force in developing advanced aerospace propulsion and power systems. One key aspect that made many of these systems possible has been the availability of high-performance, reliable, and long-life materials. To assure a continuing flow of new materials and processing concepts, basic understanding to guide such innovation, and technological support for development of major NASA systems, Lewis has supported a strong in-house materials research activity. Our researchers have discovered new alloys, polymers, metallic composites, ceramics, coatings, processing techniques, etc., which are now also in use by U.S. industry. This brochure highlights selected past accomplishments of our materials research and technology staff. It also provides many examples of the facilities available with which we can conduct materials research. The nation is now beginning to consider integrating technology for high-performance supersonic/hypersonic aircraft, nuclear space power systems, a space station, and new research areas such as materials processing in space. As we proceed, I am confident that our materials research staff will continue to provide important contributions which will help our nation maintain a strong technology position in these areas of growing world competition. Lewis Research Center, in partnership with U.S. industry and academia, has long been a major force in developing advanced aerospace propulsion and power systems. One key aspect that made many of these systems possible has been the availability of high-performance, reliable, and long-life materials. To assure a continuing flow of new materials and processing concepts, basic understanding to guide such innovation, and technological support for development of major NASA systems, Lewis has supported a strong in-house materials research activity. Our researchers have discovered new alloys, polymers, metallic composites, ceramics, coatings, processing techniques, etc., which are now also in use by U.S. industry. This brochure highlights selected past accomplishments of our materials research and technology staff. It also provides many examples of the facilities available with which we can conduct materials research. The nation is now beginning to consider integrating technology for high-performance supersonic/hypersonic aircraft, nuclear space power systems, a space station, and new research areas such as materials processing in space.

  10. Spaceflight tracking and data network operational reliability computer output for MTBF and availability. Appendix V to CSC-1-395

    NASA Technical Reports Server (NTRS)

    Seneca, V. I.; Mlynarczyk, R. H.

    1974-01-01

    Tables of data are provided to show the availability of Skylab data to selected ground stations during the phases of Skylab preflight, Skylab unmanned condition, and Skylab manned condition. The mean time between failure (MTBF) of the same Skylab functions is tabulated for the selected ground stations. All reliability data are based on a 90 percent confidence interval.

  11. How to: identify non-tuberculous Mycobacterium species using MALDI-TOF mass spectrometry.

    PubMed

    Alcaide, F; Amlerová, J; Bou, G; Ceyssens, P J; Coll, P; Corcoran, D; Fangous, M-S; González-Álvarez, I; Gorton, R; Greub, G; Hery-Arnaud, G; Hrábak, J; Ingebretsen, A; Lucey, B; Marekoviċ, I; Mediavilla-Gradolph, C; Monté, M R; O'Connor, J; O'Mahony, J; Opota, O; O'Reilly, B; Orth-Höller, D; Oviaño, M; Palacios, J J; Palop, B; Pranada, A B; Quiroga, L; Rodríguez-Temporal, D; Ruiz-Serrano, M J; Tudó, G; Van den Bossche, A; van Ingen, J; Rodriguez-Sanchez, B

    2018-06-01

    The implementation of MALDI-TOF MS for microorganism identification has changed the routine of the microbiology laboratories as we knew it. Most microorganisms can now be reliably identified within minutes using this inexpensive, user-friendly methodology. However, its application in the identification of mycobacteria isolates has been hampered by the structure of their cell wall. Improvements in the sample processing method and in the available database have proved key factors for the rapid and reliable identification of non-tuberculous mycobacteria isolates using MALDI-TOF MS. The main objective is to provide information about the proceedings for the identification of non-tuberculous isolates using MALDI-TOF MS and to review different sample processing methods, available databases, and the interpretation of the results. Results from relevant studies on the use of the available MALDI-TOF MS instruments, the implementation of innovative sample processing methods, or the implementation of improved databases are discussed. Insight about the methodology required for reliable identification of non-tuberculous mycobacteria and its implementation in the microbiology laboratory routine is provided. Microbiology laboratories where MALDI-TOF MS is available can benefit from its capacity to identify most clinically interesting non-tuberculous mycobacteria in a rapid, reliable, and inexpensive manner. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  12. Are the available apathy measures reliable and valid? A review of the psychometric evidence

    PubMed Central

    Clarke, Diana E.; Ko, Jean Y.; Kuhl, Emily A.; van Reekum, Robert; Salvador, Rocio; Marin, Robert S.

    2014-01-01

    Objective Apathy is highly prevalent among neuropsychiatric populations and is associated with greater morbidity and worse functional outcomes. Despite this, it remains understudied and poorly understood, primarily due to lack of consensus definition and clear diagnostic criteria for apathy. Without a gold standard for defining and measuring apathy, the availability of empirically sound measures is imperative. This paper provides a psychometric review of the most commonly used apathy measures and provides recommendations for use and further research. Methods Pertinent literature databases were searched to identify all available assessment tools for apathy in adults aged 18 and older. Evidence of the reliability and validity of the scales were examined. Alternate variations of scales (e.g., non-English versions) were also evaluated if the validating articles were written in English. Results Fifteen apathy scales or subscales were examined. The most psychometrically robust measures for assessing apathy across any disease population appear to be the Apathy Evaluation Scale and the apathy subscale of the Neuropsychiatric Inventory based on the criteria set in this review. For assessment in specific populations, the Dementia Apathy Interview and Rating for patients with Alzheimer’s dementia, the Positive and Negative Symptom Scale for schizophrenia populations, and the Frontal System Behavior Scale for patients with fronto-temporal deficits are reliable and valid measures. Conclusion Clinicians and researchers have numerous apathy scales for use in broad and disease-specific neuropsychiatric populations. Our understanding of apathy would be advanced by research that helps build a consensus as to the definition and diagnosis of apathy, and further refine the psychometric properties of all apathy assessment tools. PMID:21193104

  13. Validation of wet mount microscopy against Trichomonas culture among women of reproductive age group in Western province, Sri Lanka.

    PubMed

    Banneheke, H; Fernandopulle, R; Gunasekara, U; Barua, A; Fernando, N; Wickremasinghe, R

    2015-06-01

    Wet mount microscopy is the most commonly used diagnostic method for trichomoniasis in clinical diagnostic services all over the world including Sri Lanka due to its availability, simplicity and is relatively inexpensive. However, Trichomonas culture and PCR are the gold standard tests. Unfortunately, neither the culture nor PCR is available for the diagnosis of trichomoniasis in Sri Lanka. Thus, it is important to validate the wet mount microscopy as it is the only available diagnostic test and has not been validated to date in Sri Lanka. The objective was to evaluate the validity and reliability of wet mount microscopy against gold standard Trichomonas culture among clinic based population of reproductive age group women in Western province, Sri Lanka. Women attending hospital and institutional based clinics were enrolled. They were interviewed and high vaginal swabs were taken for laboratory diagnosis by culture and wet mount microscopy. There were 601 participants in the age group of 15-45 years. Wet mount microscopy showed 68% sensitivity, 100% specificity, 100% positive (PPV) and 98% negative predictive values (NPV) (P=0.001, kappa=0.803) respectively against the gold standard culture. The area under the ROC curve was 0.840. Sensitivity of wet mount microscopy is low. However it has high validity and reliability as a specific diagnostic test for trichomoniasis. If it is to be used among women of reproductive age group in Western province, Sri Lanka, a culture method could be adopted as a second test to confirm the negative wet mount for symptomatic patients.

  14. Aging analysis of high performance FinFET flip-flop under Dynamic NBTI simulation configuration

    NASA Astrophysics Data System (ADS)

    Zainudin, M. F.; Hussin, H.; Halim, A. K.; Karim, J.

    2018-03-01

    A mechanism known as Negative-bias Temperature Instability (NBTI) degrades a main electrical parameters of a circuit especially in terms of performance. So far, the circuit design available at present are only focussed on high performance circuit without considering the circuit reliability and robustness. In this paper, the main circuit performances of high performance FinFET flip-flop such as delay time, and power were studied with the presence of the NBTI degradation. The aging analysis was verified using a 16nm High Performance Predictive Technology Model (PTM) based on different commands available at Synopsys HSPICE. The results shown that the circuit under the longer dynamic NBTI simulation produces the highest impact in the increasing of gate delay and decrease in the average power reduction from a fresh simulation until the aged stress time under a nominal condition. In addition, the circuit performance under a varied stress condition such as temperature and negative stress gate bias were also studied.

  15. Space Station Freedom electric power system availability study

    NASA Technical Reports Server (NTRS)

    Turnquist, Scott R.

    1990-01-01

    The results are detailed of follow-on availability analyses performed on the Space Station Freedom electric power system (EPS). The scope includes analyses of several EPS design variations, these are: the 4-photovoltaic (PV) module baseline EPS design, a 6-PV module EPS design, and a 3-solar dynamic module EPS design which included a 10 kW PV module. The analyses performed included: determining the discrete power levels that the EPS will operate at upon various component failures and the availability of each of these operating states; ranking EPS components by the relative contribution each component type gives to the power availability of the EPS; determining the availability impacts of including structural and long-life EPS components in the availability models used in the analyses; determining optimum sparing strategies, for storing space EPS components on-orbit, to maintain high average-power-capability with low lift-mass requirements; and analyses to determine the sensitivity of EPS-availability to uncertainties in the component reliability and maintainability data used.

  16. High Throughput Screening for Anti–Trypanosoma cruzi Drug Discovery

    PubMed Central

    Alonso-Padilla, Julio; Rodríguez, Ana

    2014-01-01

    The discovery of new therapeutic options against Trypanosoma cruzi, the causative agent of Chagas disease, stands as a fundamental need. Currently, there are only two drugs available to treat this neglected disease, which represents a major public health problem in Latin America. Both available therapies, benznidazole and nifurtimox, have significant toxic side effects and their efficacy against the life-threatening symptomatic chronic stage of the disease is variable. Thus, there is an urgent need for new, improved anti–T. cruzi drugs. With the objective to reliably accelerate the drug discovery process against Chagas disease, several advances have been made in the last few years. Availability of engineered reporter gene expressing parasites triggered the development of phenotypic in vitro assays suitable for high throughput screening (HTS) as well as the establishment of new in vivo protocols that allow faster experimental outcomes. Recently, automated high content microscopy approaches have also been used to identify new parasitic inhibitors. These in vitro and in vivo early drug discovery approaches, which hopefully will contribute to bring better anti–T. cruzi drug entities in the near future, are reviewed here. PMID:25474364

  17. High throughput screening for anti-Trypanosoma cruzi drug discovery.

    PubMed

    Alonso-Padilla, Julio; Rodríguez, Ana

    2014-12-01

    The discovery of new therapeutic options against Trypanosoma cruzi, the causative agent of Chagas disease, stands as a fundamental need. Currently, there are only two drugs available to treat this neglected disease, which represents a major public health problem in Latin America. Both available therapies, benznidazole and nifurtimox, have significant toxic side effects and their efficacy against the life-threatening symptomatic chronic stage of the disease is variable. Thus, there is an urgent need for new, improved anti-T. cruzi drugs. With the objective to reliably accelerate the drug discovery process against Chagas disease, several advances have been made in the last few years. Availability of engineered reporter gene expressing parasites triggered the development of phenotypic in vitro assays suitable for high throughput screening (HTS) as well as the establishment of new in vivo protocols that allow faster experimental outcomes. Recently, automated high content microscopy approaches have also been used to identify new parasitic inhibitors. These in vitro and in vivo early drug discovery approaches, which hopefully will contribute to bring better anti-T. cruzi drug entities in the near future, are reviewed here.

  18. Technical Challenges and Potential Solutions for Cross-Country Multi-Terminal Superconducting DC Power Cables

    NASA Astrophysics Data System (ADS)

    Al-Taie, A.; Graber, L.; Pamidi, S. V.

    2017-12-01

    Opportunities for applications of high temperature superconducting (HTS) DC power cables for long distance power transmission in increasing the reliability of the electric power grid and to enable easier integration of distributed renewable sources into the grid are discussed. The gaps in the technology developments both in the superconducting cable designs and cryogenic systems as well as power electronic devices are identified. Various technology components in multi-terminal high voltage DC power transmission networks and the available options are discussed. The potential of ongoing efforts in the development of superconducting DC transmission systems is discussed.

  19. Long-Term Reliability of a Hard-Switched Boost Power Processing Unit Utilizing SiC Power MOSFETs

    NASA Technical Reports Server (NTRS)

    Ikpe, Stanley A.; Lauenstein, Jean-Marie; Carr, Gregory A.; Hunter, Don; Ludwig, Lawrence L.; Wood, William; Iannello, Christopher J.; Del Castillo, Linda Y.; Fitzpatrick, Fred D.; Mojarradi, Mohammad M.; hide

    2016-01-01

    Silicon carbide (SiC) power devices have demonstrated many performance advantages over their silicon (Si) counterparts. As the inherent material limitations of Si devices are being swiftly realized, wide-band-gap (WBG) materials such as SiC have become increasingly attractive for high power applications. In particular, SiC power metal oxide semiconductor field effect transistors' (MOSFETs) high breakdown field tolerance, superior thermal conductivity and low-resistivity drift regions make these devices an excellent candidate for power dense, low loss, high frequency switching applications in extreme environment conditions. In this paper, a novel power processing unit (PPU) architecture is proposed utilizing commercially available 4H-SiC power MOSFETs from CREE Inc. A multiphase straight boost converter topology is implemented to supply up to 10 kilowatts full-scale. High Temperature Gate Bias (HTGB) and High Temperature Reverse Bias (HTRB) characterization is performed to evaluate the long-term reliability of both the gate oxide and the body diode of the SiC components. Finally, susceptibility of the CREE SiC MOSFETs to damaging effects from heavy-ion radiation representative of the on-orbit galactic cosmic ray environment are explored. The results provide the baseline performance metrics of operation as well as demonstrate the feasibility of a hard-switched PPU in harsh environments.

  20. Innovative on board payload optical architecture for high throughput satellites

    NASA Astrophysics Data System (ADS)

    Baudet, D.; Braux, B.; Prieur, O.; Hughes, R.; Wilkinson, M.; Latunde-Dada, K.; Jahns, J.; Lohmann, U.; Fey, D.; Karafolas, N.

    2017-11-01

    For the next generation of HighThroughPut (HTP) Telecommunications Satellites, space end users' needs will result in higher link speeds and an increase in the number of channels; up to 512 channels running at 10Gbits/s. By keeping electrical interconnections based on copper, the constraints in term of power dissipation, number of electrical wires and signal integrity will become too demanding. The replacement of the electrical links by optical links is the most adapted solution as it provides high speed links with low power consumption and no EMC/EMI. But replacing all electrical links by optical links of an On Board Payload (OBP) is challenging. It is not simply a matter of replacing electrical components with optical but rather the whole concept and architecture have to be rethought to achieve a high reliability and high performance optical solution. In this context, this paper will present the concept of an Innovative OBP Optical Architecture. The optical architecture was defined to meet the critical requirements of the application: signal speed, number of channels, space reliability, power dissipation, optical signals crossing and components availability. The resulting architecture is challenging and the need for new developments is highlighted. But this innovative optically interconnected architecture will substantially outperform standard electrical ones.

  1. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    PubMed

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  2. Attention-deficit/hyperactivity disorder dimensionality: the reliable 'g' and the elusive 's' dimensions.

    PubMed

    Wagner, Flávia; Martel, Michelle M; Cogo-Moreira, Hugo; Maia, Carlos Renato Moreira; Pan, Pedro Mario; Rohde, Luis Augusto; Salum, Giovanni Abrahão

    2016-01-01

    The best structural model for attention-deficit/hyperactivity disorder (ADHD) symptoms remains a matter of debate. The objective of this study is to test the fit and factor reliability of competing models of the dimensional structure of ADHD symptoms in a sample of randomly selected and high-risk children and pre-adolescents from Brazil. Our sample comprised 2512 children aged 6-12 years from 57 schools in Brazil. The ADHD symptoms were assessed using parent report on the development and well-being assessment (DAWBA). Fit indexes from confirmatory factor analysis were used to test unidimensional, correlated, and bifactor models of ADHD, the latter including "g" ADHD and "s" symptom domain factors. Reliability of all models was measured with omega coefficients. A bifactor model with one general factor and three specific factors (inattention, hyperactivity, impulsivity) exhibited the best fit to the data, according to fit indices, as well as the most consistent factor loadings. However, based on omega reliability statistics, the specific inattention, hyperactivity, and impulsivity dimensions provided very little reliable information after accounting for the reliable general ADHD factor. Our study presents some psychometric evidence that ADHD specific ("s") factors might be unreliable after taking common ("g" factor) variance into account. These results are in accordance with the lack of longitudinal stability among subtypes, the absence of dimension-specific molecular genetic findings and non-specific effects of treatment strategies. Therefore, researchers and clinicians might most effectively rely on the "g" ADHD to characterize ADHD dimensional phenotype, based on currently available symptom items.

  3. QoSLight: a new quality of service FSO software

    NASA Astrophysics Data System (ADS)

    Chabane, Mourad; Alnaboulsi, Maher; Sizun, Herve; Bouchet, Olivier

    2003-08-01

    The atmospheric optical links (FSO) in visible and infrared wavelengths constitute an interesting alternative to creation of new transmission channels for the cordless phone, data-processing networks and high definition television. One finds a choice of varied manufacturers and they propose products whose performances are characterized by a raised rate of transmission, from 2 Mbps to 10 Gbps. But the announced ranges are very important, from 100 to 10,000 meters, in spite of the fact that many manufacturers try to indicate the possible ranges according to time, these indications completely miss standardization and are hardly exploitable because, generally, it is very difficult to know the percentage of time during which a value is reached or exceeded. Availability and reliability of a FSO link depend on used systems but also on climatic and atmospheric parameters such as rain, snow or fog. Library search underlined the lack of reliable data to be able to lay down, in a precise way, the statistical availability of such links, like one usually does for the radio transmission. Before to implement an effective FSO links, we need to know their availability and their reliability. It is the purpose of our study. Its finality is a software which integrate (1) Results of a library search (geometrical attenuation, aerosols, scintillation, environment light, etc), (2) English and French integrated surface weather data, hour per hour, over several years (1995-1999). The result is the presentation of this software, "QoSLight" (Quality of Service Light), making it possible to predict; starting from the data of equipment (power, wavelength, receiver sensibility), geographical situation of a site in France or England (geographical coordinates, altitude, height/ground) and climatic and atmospheric parameter (relative humidity, ground rugosity, albedo, solar radiation, etc) the availability of a FSO link for the following period (year, the most unfavourable month, 8am to 8pm period and 8 am period. The interruption probabilities for each type of attenuation are also mentioned (aerosols, scintillation, ambient solar light, rain, snow, etc).

  4. Validation of a score tool for measurement of histological severity in juvenile dermatomyositis and association with clinical severity of disease

    PubMed Central

    Varsani, Hemlata; Charman, Susan C; Li, Charles K; Marie, Suely K N; Amato, Anthony A; Banwell, Brenda; Bove, Kevin E; Corse, Andrea M; Emslie-Smith, Alison M; Jacques, Thomas S; Lundberg, Ingrid E; Minetti, Carlo; Nennesmo, Inger; Rushing, Elisabeth J; Sallum, Adriana M E; Sewry, Caroline; Pilkington, Clarissa A; Holton, Janice L; Wedderburn, Lucy R

    2015-01-01

    Objectives To study muscle biopsy tissue from patients with juvenile dermatomyositis (JDM) in order to test the reliability of a score tool designed to quantify the severity of histological abnormalities when applied to biceps humeri in addition to quadriceps femoris. Additionally, to evaluate whether elements of the tool correlate with clinical measures of disease severity. Methods 55 patients with JDM with muscle biopsy tissue and clinical data available were included. Biopsy samples (33 quadriceps, 22 biceps) were prepared and stained using standardised protocols. A Latin square design was used by the International Juvenile Dermatomyositis Biopsy Consensus Group to score cases using our previously published score tool. Reliability was assessed by intraclass correlation coefficient (ICC) and scorer agreement (α) by assessing variation in scorers’ ratings. Scores from the most reliable tool items correlated with clinical measures of disease activity at the time of biopsy. Results Inter- and intraobserver agreement was good or high for many tool items, including overall assessment of severity using a Visual Analogue Scale. The tool functioned equally well on biceps and quadriceps samples. A modified tool using the most reliable score items showed good correlation with measures of disease activity. Conclusions The JDM biopsy score tool has high inter- and intraobserver agreement and can be used on both biceps and quadriceps muscle tissue. Importantly, the modified tool correlates well with clinical measures of disease activity. We propose that standardised assessment of muscle biopsy tissue should be considered in diagnostic investigation and clinical trials in JDM. PMID:24064003

  5. A reliability analysis of the revised competitiveness index.

    PubMed

    Harris, Paul B; Houston, John M

    2010-06-01

    This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.

  6. Software For Computing Reliability Of Other Software

    NASA Technical Reports Server (NTRS)

    Nikora, Allen; Antczak, Thomas M.; Lyu, Michael

    1995-01-01

    Computer Aided Software Reliability Estimation (CASRE) computer program developed for use in measuring reliability of other software. Easier for non-specialists in reliability to use than many other currently available programs developed for same purpose. CASRE incorporates mathematical modeling capabilities of public-domain Statistical Modeling and Estimation of Reliability Functions for Software (SMERFS) computer program and runs in Windows software environment. Provides menu-driven command interface; enabling and disabling of menu options guides user through (1) selection of set of failure data, (2) execution of mathematical model, and (3) analysis of results from model. Written in C language.

  7. Test-retest reliability and responsiveness of gaze stability and dynamic visual acuity in high school and college football players.

    PubMed

    Kaufman, Denise R; Puckett, Mallory J; Smith, Mitchell J; Wilson, Kyle S; Cheema, Rebecca; Landers, Merrill R

    2014-08-01

    The purpose of this study was to establish reliability and responsiveness of the dynamic visual acuity test (DVAT) at head speeds of 150-200 degrees per second (deg/s) and the gaze stabilization test (GST) in high school and college football players. Reliability design. Fifty high school and college football athletes completed the DVAT and GST in both the yaw (horizontal) and pitch (vertical) planes twice within two weeks. Test-retest reliability for the DVAT was good in yaw, Intraclass Correlation Coefficient (ICC) = 0.770, and moderate/good in pitch, ICC = 0.725. Minimal detectable change (MDC) was 0.16 logMAR for yaw and 0.21 logMAR for pitch. GST reliability was moderate in yaw, ICC = 0.634, and poor in pitch, ICC = 0.411. MDCs were 73.4 deg/s (yaw) and 81.2 deg/s (pitch). The DVAT is reliable at high head speeds in high school and college football athletes in both yaw and pitch. GST head speeds were higher than previously reported in the literature, but reliability of this tool for this population was poor to moderate. From a clinical perspective, DVAT may be reliably used in the assessment of high school and college football athletes; however, GST requires further evaluation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. On the design of high-rise buildings with a specified level of reliability

    NASA Astrophysics Data System (ADS)

    Dolganov, Andrey; Kagan, Pavel

    2018-03-01

    High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.

  9. Validity and reliability of the semi-quantitative self-report Home Food Availability Inventory Checklist (HFAI-C) in White and South Asian populations.

    PubMed

    Bryant, Maria; LeCroy, Madison; Sahota, Pinki; Cai, Jianwen; Stevens, June

    2016-05-04

    Despite interest in the importance of the home food environment and its potential influence on children's diets and social norms, there remain few self-report checklist methods that have been validated against the gold standard of researcher-conducted inventories. This study aimed to assess the criterion validity and reliability of the 'Home Food Availability Inventory Checklist' (HFAI-C), a 39-item checklist including categories of fruit, vegetables, snacks and drinks. The HFAI-C was completed by 97 participants of White and Pakistani origin in the UK. Validity was determined by comparing participant-reported HFAI-C responses to data from researcher observations of home food availability using PABAK and weighted kappa statistics. The validity of measuring the amount of items (in addition to presence/absence) available was also determined. Test-retest reliability compared repeated administrations of the HFAI-C using intra-class correlation coefficients. Validity and reliability was fair to moderate overall. For validity, the average category-level PABAK ranged from 0.31 (95% CI: 0.25, 0.37) for vegetables to 0.44 (95% CI: 0.40, 0.49) for fruits. Assessment of the presence/absence of items demonstrated higher validity compared to quantity measurements. Reliability was increased when the HFAI-C was repeated close to the time of the first administration. For example, ICCs for reliability of the measurement of fruits were 0.52 (95%CI: 0.47, 0.56) if re-administered within 5 months, 0.58 (95% CI: 0.51, 0.64) within 30 days and 0.97 (95%CI: 0.94, 1.00) if re-administered on the same day. Overall, the HFAI-C demonstrated fair to moderate validity and reliability in a population of White and South Asian participants. This evaluation is consistent with previous work on other checklists in less diverse, more affluent populations. Our research supports the use of the HFAI-C as a useful, albeit imperfect, representation of researcher-conducted inventories. The feasibility of collecting information using the HFAI-C in large, multi-ethnic samples can facilitate examination of home food availability in relation to exposures such as ethnicity and outcomes including behavioural, social and health outcomes. Future work using the HFAI-C could provide important insights into a modifiable influence with potential to impact health.

  10. Effectiveness of glucose monitoring systems modified for the visually impaired.

    PubMed

    Bernbaum, M; Albert, S G; Brusca, S; McGinnis, J; Miller, D; Hoffmann, J W; Mooradian, A D

    1993-10-01

    To compare three glucose meters modified for use by individuals with diabetes and visual impairment regarding accuracy, precision, and clinical reliability. Ten subjects with diabetes and visual impairment performed self-monitoring of blood glucose using each of the three commercially available blood glucose meters modified for visually impaired users (the AccuChek Freedom [Boehringer Mannheim, Indianapolis, IN], the Diascan SVM [Home Diagnostics, Eatontown, NJ], and the One Touch [Lifescan, Milpitas, CA]). The meters were independently evaluated by a laboratory technologist for precision and accuracy determinations. Only two meters were acceptable with regard to laboratory precision (coefficient of variation < 10%)--the Accuchek and the One Touch. The Accuchek and the One Touch did not differ significantly with regard to laboratory estimates of accuracy. A great discrepancy of the clinical reliability results was observed between these two meters. The Accuchek maintained a high degree of reliability (y = 0.99X + 0.44, r = 0.97, P = 0.001). The visually impaired subjects were unable to perform reliable testing using the One Touch system because of a lack of appropriate tactile landmarks and auditory signals. In addition to laboratory assessments of glucose meters, monitoring systems designed for the visually impaired must include adequate tactile and audible feedback features to allow for the acquisition and placement of appropriate blood samples.

  11. Reliability, Durability and Packaging of Fibre Bragg Gratings for Large-Scale Structural Health Monitoring of Defence Platforms

    DTIC Science & Technology

    2013-08-01

    thermoset system designed to achieve good wetting , high-strength and low-creep adhesion. Many commercially-available adhesives were sourced and...Bragg grating: 1. Removal of the fibre coating. 2. Photosensitization of the fibre. 3. Exposure of the grating to UV laser light. 4. Annealing and...molecular hydrogen loading (H2 loading) in a heated pressure vessel . Photosensitisation results in a stronger refractive index contrast for a given

  12. Solid-state Terahertz Sources for Space Applications

    NASA Technical Reports Server (NTRS)

    Maiwald, Frank; Pearson, John C.; Ward, John S.; Schlecht, Erich; Chattopadhyay, Goutam; Gill, John J.; Ferber, R.; Tsang, Raymond; Lin, Robert H.; Peralta, Alejandro; hide

    2004-01-01

    This paper discusses the construction of solid-state frequency multiplier chains utilized far teraherz receiver applications such as the Herschel Space Observatory . Emphasis will he placed on the specific requirements to be met and challenges that were encountered. The availability of high power amplifiers at 100 GHz makes it possible to cascade frequency doublers and triplers with sufficient RF power to pump heterodyne receivers at THz frequencies. The environmental and mechanical constraints will be addressed as well as reliability issues.

  13. Contraceptive knowledge, attitudes, and practice in Russia during the 1980s.

    PubMed

    Popov, A A; Visser, A P; Ketting, E

    1993-01-01

    In the former Soviet Union, there was a lack of valid and reliable social research on knowledge, attitudes, and practice of contraception. The few available studies have not been published outside the Soviet Union. This article reviews five surveys that were conducted in Moscow and two other cities (Saratov and Tartu) during the period 1976-84. In addition, some data from a large-scale survey conducted in 1990 and covering the entire former Soviet Union are presented. The surveys indicate that the rhythm method, condoms, vaginal douches, and withdrawal were the main contraceptive methods used; only 1 to 3 percent of the women interviewed were using oral contraceptives, and about 10 percent used intrauterine devices. The low prevalence of use of reliable modern methods may explain the high incidence of induced abortion in Russia. The chronic unavailability of reliable contraceptives is one of the main factors of poor family planning. Lack of knowledge and negative opinions about modern contraception also play an important role. Some possibilities for improving the family planning situation in Russia are discussed.

  14. Developing of an automation for therapy dosimetry systems by using labview software

    NASA Astrophysics Data System (ADS)

    Aydin, Selim; Kam, Erol

    2018-06-01

    Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. Therefore it is very important to provide reliable, accurate and fast calibration services for therapy dosimeters since the radiation dose delivered to a radiotherapy patient is directly related to accuracy and reliability of these devices. In this study, we report the performance of in-house developed computer controlled data acquisition and monitoring software for the commercially available radiation therapy electrometers. LabVIEW® software suite is used to provide reliable, fast and accurate calibration services. The software also collects environmental data such as temperature, pressure and humidity in order to use to use these them in correction factor calculations. By using this software tool, a better control over the calibration process is achieved and the need for human intervention is reduced. This is the first software that can control frequently used dosimeter systems, in radiation thereapy field at hospitals, such as Unidos Webline, Unidos E, Dose-1 and PC Electrometers.

  15. Promoting Robust Design of Diode Lasers for Space: A National Initiative

    NASA Technical Reports Server (NTRS)

    Tratt, David M.; Amzajerdian, Farzin; Kashem, Nasir B.; Shapiro, Andrew A.; Mense, Allan T.

    2007-01-01

    The Diode-laser Array Working Group (DAWG) is a national-level consumer/provider forum for discussion of engineering and manufacturing issues which influence the reliability and survivability of high-power broad-area laser diode devices in space, with an emphasis on laser diode arrays (LDAs) for optical pumping of solid-state laser media. The goals of the group are to formulate and validate standardized test and qualification protocols, operational control recommendations, and consensus manufacturing and certification standards. The group is using reliability and lifetime data collected by laser diode manufacturers and the user community to develop a set of standardized guidelines for specifying and qualifying laser diodes for long-duration operation in space, the ultimate goal being to promote an informed U.S. Government investment and procurement strategy for assuring the availability and durability of space-qualified LDAs. The group is also working to establish effective implementation of statistical design techniques at the supplier design, development, and manufacturing levels to help reduce product performance variability and improve product reliability for diodes employed in space applications

  16. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring

    PubMed Central

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-01-01

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized. PMID:29414849

  17. Reliability of Beam Loss Monitors System for the Large Hadron Collider

    NASA Astrophysics Data System (ADS)

    Guaglio, G.; Dehning, B.; Santoni, C.

    2004-11-01

    The employment of superconducting magnets in high energy colliders opens challenging failure scenarios and brings new criticalities for the whole system protection. For the LHC beam loss protection system, the failure rate and the availability requirements have been evaluated using the Safety Integrity Level (SIL) approach. A downtime cost evaluation is used as input for the SIL approach. The most critical systems, which contribute to the final SIL value, are the dump system, the interlock system, the beam loss monitors system and the energy monitor system. The Beam Loss Monitors System (BLMS) is critical for short and intense particle losses, while at medium and higher loss time it is assisted by other systems, such as the quench protection system and the cryogenic system. For BLMS, hardware and software have been evaluated in detail. The reliability input figures have been collected using historical data from the SPS, using temperature and radiation damage experimental data as well as using standard databases. All the data have been processed by reliability software (Isograph). The analysis ranges from the components data to the system configuration.

  18. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    PubMed

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  19. Comparison of the efficacy of MODIS and MERIS data for detecting cyanobacterial blooms in the southern Caspian Sea.

    PubMed

    Moradi, Masoud

    2014-10-15

    Medium Resolution Imaging Spectrometer (MERIS) data, Moderate Resolution Imaging Spectroradiometer (MODIS) data, and hydro-biological measurements were used to detect two very severe blooms in the southern Caspian Sea in 2005 and 2010. The MERIS Cyanobacteria Index (CIMERIS) was more reliable for detecting cyanobacterial blooms. The CIMERIS and MODIS cyanobacteria indices (CIMODIS) were compared in an effort to find a reliable method for detecting future blooms, as MERIS data were not available after April 2012. The CIMODIS had a linear relationship with and similar spatial patterns to the CIMERIS. On the CIMODIS images, extremely high biomass cyanobacteria patches were masked. A comparison of classified in situ data with the CIMODIS and Floating Algal Index (FAI) from four images of a severe bloom event in 2005 showed that the FAI is a reliable index for bloom detection over extremely dense patches. The corrected CIMODIS, the MODIS FAI and in situ data are adequate tools for cyanobacterial bloom monitoring in the southern Caspian Sea. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Construction and validation of educational materials for the prevention of metabolic syndrome in adolescents 1

    PubMed Central

    de Moura, Ionara Holanda; da Silva, Antônia Fabiana Rodrigues; Rocha, Aparecida do Espírito Santo de Holanda; Lima, Luisa Helena de Oliveira; Moreira, Thereza Maria Magalhães; da Silva, Ana Roberta Vilarouca

    2017-01-01

    ABSTRACT Objective: To develop and validate an educational technology focused on prevention of metabolic syndrome among adolescents. Methods: This was methodological research. Using an integrative review, the available publications on the subject were analyzed. Then, this knowledge was used to describe the theoretical content and, with the help of a graphic designer, the art and layout of the pages were developed. In the third phase, the booklet was evaluated and validated by 21 specialists and 39 adolescents. Data collection included three different questionnaires, according to the focus of evaluation of each group of participants, analyzed for reliability (Cronbach’s Alpha) and agreement by Infraclass Correlation Coefficient. Results: The mean score attributed by technical content experts was 91.7%, and the content validity index, measured by experts responses, was 0.98, showing high reliability and agreement. In addition, the level of agreement of the positive responses given by adolescents was 88.4%. Conclusion: the educational booklet has proved to be a valid and reliable tool to be used for promoting adolescent health. PMID:29020125

  1. Reliability of an e-PRO Tool of EORTC QLQ-C30 for Measurement of Health-Related Quality of Life in Patients With Breast Cancer: Prospective Randomized Trial.

    PubMed

    Wallwiener, Markus; Matthies, Lina; Simoes, Elisabeth; Keilmann, Lucia; Hartkopf, Andreas D; Sokolov, Alexander N; Walter, Christina B; Sickenberger, Nina; Wallwiener, Stephanie; Feisst, Manuel; Gass, Paul; Fasching, Peter A; Lux, Michael P; Wallwiener, Diethelm; Taran, Florin-Andrei; Rom, Joachim; Schneeweiss, Andreas; Graf, Joachim; Brucker, Sara Y

    2017-09-14

    Breast cancer represents the most common malignant disease in women worldwide. As currently systematic palliative treatment only has a limited effect on survival rates, the concept of health-related quality of life (HRQoL) is gaining more and more importance in the therapy setting of metastatic breast cancer. One of the major patient-reported outcomes (PROs) for measuring HRQoL in patients with breast cancer is provided by the European Organization for Research and Treatment of Cancer (EORTC). Currently, paper-based surveys still predominate, as only a few reliable and validated electronic-based questionnaires are available. Facing the possibilities associated with evolving digitalization in medicine, validation of electronic versions of well-established PRO is essential in order to contribute to comprehensive and holistic oncological care and to ensure high quality in cancer research. The aim of this study was to analyze the reliability of a tablet-based measuring application for EORTC QLQ-C30 in German language in patients with adjuvant and (curative) metastatic breast cancer. Paper- and tablet-based questionnaires were completed by a total of 106 female patients with adjuvant and metastatic breast cancer recruited as part of the e-PROCOM study. All patients were required to complete the electronic- (e-PRO) and paper-based versions of the HRQoL EORTC QLQ-C30 questionnaire. A frequency analysis was performed to determine descriptive sociodemographic characteristics. Both dimensions of reliability (parallel forms reliability [Wilcoxon test] and test of internal consistency [Spearman rho and agreement rates for single items, Pearson correlation and Kendall tau for each scale]) were analyzed. High correlations were shown for both dimensions of reliability (parallel forms reliability and internal consistency) in the patient's response behavior between paper- and electronic-based questionnaires. Regarding the test of parallel forms reliability, no significant differences were found in 27 of 30 single items and in 14 of 15 scales, whereas a statistically significant correlation in the test of consistency was found in all 30 single items and all 15 scales. The evaluated e-PRO version of the EORTC QLQ-C30 is reliable for patients with both adjuvant and metastatic breast cancer, showing a high correlation in almost all questions (and in many scales). Thus, we conclude that the validated paper-based PRO assessment and the e-PRO tool are equally valid. However, the reliability should also be analyzed in other prospective trials to ensure that usability is reliable in all patient groups. ClinicalTrials.gov NCT03132506; https://clinicaltrials.gov/ct2/show/NCT03132506 (Archived by WebCite at http://www.webcitation.org/6tRcgQuou). ©Markus Wallwiener, Lina Matthies, Elisabeth Simoes, Lucia Keilmann, Andreas D Hartkopf, Alexander N Sokolov, Christina B Walter, Nina Sickenberger, Stephanie Wallwiener, Manuel Feisst, Paul Gass, Peter A Fasching, Michael P Lux, Diethelm Wallwiener, Florin-Andrei Taran, Joachim Rom, Andreas Schneeweiss, Joachim Graf, Sara Y Brucker. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 14.09.2017.

  2. Test-retest reliability of the Capute scales for neurodevelopmental screening of a high risk sample: Impact of test-retest interval and degree of neonatal risk.

    PubMed

    McCurdy, M; Bellows, A; Deng, D; Leppert, M; Mahone, E; Pritchard, A

    2015-01-01

    Reliable and valid screening and assessment tools are necessary to identify children at risk for neurodevelopmental disabilities who may require additional services. This study evaluated the test-retest reliability of the Capute Scales in a high-risk sample, hypothesizing adequate reliability across 6- and 12-month intervals. Capute Scales scores (N = 66) were collected via retrospective chart review from a NICU follow-up clinic within a large urban medical center spanning three age-ranges: 12-18, 19-24, and 25-36 months. On average, participants were classified as very low birth weight and premature. Reliability of the Capute Scales was evaluated with intraclass correlation coefficients across length of test-retest interval, age at testing, and degree of neonatal complications. The Capute Scales demonstrated high reliability, regardless of length of test-retest interval (ranging from 6 to 14 months) or age of participant, for all index scores, including overall Developmental Quotient (DQ), language-based skill index (CLAMS) and nonverbal reasoning index (CAT). Linear regressions revealed that greater neonatal risk was related to poorer test-retest reliability; however, reliability coefficients remained strong. The Capute Scales afford clinicians a reliable and valid means of screening and assessing for neurodevelopmental delay within high-risk infant populations.

  3. Reliability of Leg and Vertical Stiffness During High Speed Treadmill Running.

    PubMed

    Pappas, Panagiotis; Dallas, Giorgos; Paradisis, Giorgos

    2017-04-01

    In research, the accurate and reliable measurement of leg and vertical stiffness could contribute to valid interpretations. The current study aimed at determining the intraparticipant variability (ie, intraday and interday reliabilities) of leg and vertical stiffness, as well as related parameters, during high speed treadmill running, using the "sine-wave" method. Thirty-one males ran on a treadmill at 6.67 m∙s -1 , and the contact and flight times were measured. To determine the intraday reliability, three 10-s running bouts with 10-min recovery were performed. In addition, to examine the interday reliability, three 10-s running bouts on 3 separate days with 48-h interbout intervals were performed. The reliability statistics included repeated-measure analysis of variance, average intertrial correlations, intraclass correlation coefficients (ICCs), Cronbach's α reliability coefficient, and the coefficient of variation (CV%). Both intraday and interday reliabilities were high for leg and vertical stiffness (ICC > 0.939 and CV < 4.3%), as well as related variables (ICC > 0.934 and CV < 3.9%). It was thus inferred that the measurements of leg and vertical stiffness, as well as the related parameters obtained using the "sine-wave" method during treadmill running at 6.67 m∙s -1 , were highly reliable, both within and across days.

  4. Measurement of availability and accessibility of food among youth: a systematic review of methodological studies.

    PubMed

    Gebremariam, Mekdes K; Vaqué-Crusellas, Cristina; Andersen, Lene F; Stok, F Marijn; Stelmach-Mardas, Marta; Brug, Johannes; Lien, Nanna

    2017-02-14

    Comprehensive and psychometrically tested measures of availability and accessibility of food are needed in order to explore availability and accessibility as determinants and predictors of dietary behaviors. The main aim of this systematic review was to update the evidence regarding the psychometric properties of measures of food availability and accessibility among youth. A secondary objective was to assess how availability and accessibility were conceptualized in the included studies. A systematic literature search was conducted using Medline, Embase, PsycINFO and Web of Science. Methodological studies published between January 2010 and March 2016 and reporting on at least one psychometric property of a measure of availability and/or accessibility of food among youth were included. Two reviewers independently extracted data and assessed study quality. Existing criteria were used to interpret reliability and validity parameters. A total of 20 studies were included. While 16 studies included measures of food availability, three included measures of both availability and accessibility; one study included a measure of accessibility only. Different conceptualizations of availability and accessibility were used across the studies. The measures aimed at assessing availability and/or accessibility in the home environment (n = 11), the school (n = 4), stores (n = 3), childcare/early care and education services (n = 2) and restaurants (n = 1). Most studies followed systematic steps in the development of the measures. The most common psychometrics tested for these measures were test-retest reliability and criterion validity. The majority of the measures had satisfactory evidence of reliability and/or validity. None of the included studies assessed the responsiveness of the measures. The review identified several measures of food availability or accessibility among youth with satisfactory evidence of reliability and/or validity. Findings indicate a need for more studies including measures of accessibility and addressing its conceptualization. More testing of some of the identified measures in different population groups is also warranted, as is the development of more measures of food availability and accessibility in the broader environment such as the neighborhood food environment.

  5. Stellar laboratories: new Ge V and Ge VI oscillator strengths and their validation in the hot white dwarf RE 0503-289

    NASA Astrophysics Data System (ADS)

    Rauch, T.; Werner, K.; Biémont, É.; Quinet, P.; Kruk, J. W.

    2012-10-01

    Context. State-of-the-art spectral analysis of hot stars by means of non-LTE model-atmosphere techniques has arrived at a high level of sophistication. The analysis of high-resolution and high-S/N spectra, however, is strongly restricted by the lack of reliable atomic data for highly ionized species from intermediate-mass metals to trans-iron elements. Especially data for the latter has only been sparsely calculated. Many of their lines are identified in spectra of extremely hot, hydrogen-deficient post-AGB stars. A reliable determination of their abundances establishes crucial constraints for AGB nucleosynthesis simulations and, thus, for stellar evolutionary theory. Aims: In a previous analysis of the UV spectrum of RE 0503-289, spectral lines of highly ionized Ga, Ge, As, Se, Kr, Mo, Sn, Te, I, and Xe were identified. Individual abundance determinations are hampered by the lack of reliable oscillator strengths. Most of these identified lines stem from Ge V. In addition, we identified Ge VI lines for the first time. We calculated Ge V and Ge VI oscillator strengths in order to reproduce the observed spectrum. Methods: We newly calculated Ge V and Ge VI oscillator strengths to consider their radiative and collisional bound-bound transitions in detail in our non-LTE stellar-atmosphere models for the analysis of the Ge iv-vi spectrum exhibited in high-resolution and high-S/N FUV (FUSE) and UV (ORFEUS/BEFS, IUE) observations of RE 0503-289. Results: In the UV spectrum of RE 0503-289, we identify four Ge IV, 37 Ge V, and seven Ge VI lines. Most of these lines are identified for the first time in any star. We can reproduce almost all Ge IV, Ge V, and Ge VI lines in the observed spectrum of RE 0503-289 (Teff = 70 kK, log g = 7.5) at log Ge = -3.8 ± 0.3 (mass fraction, about 650 times solar). The Ge iv/v/vi ionization equilibrium, that is a very sensitive Teff indicator, is reproduced well. Conclusions: Reliable measurements and calculations of atomic data are a prerequisite for stellar-atmosphere modeling. Our oscillator-strength calculations have allowed, for the first time, Ge V and Ge VI lines to be successfully reproduced in a white dwarf's (RE 0503-289) spectrum and to determine its photospheric Ge abundance. Based on observations made with the NASA-CNES-CSA Far Ultraviolet Spectroscopic Explorer.Figures 4-6 and Tables 1, 3 are available in electronic form at http://www.aanda.orgTables 2 and 4 are only available at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/546/A55

  6. MEMS reliability: coming of age

    NASA Astrophysics Data System (ADS)

    Douglass, Michael R.

    2008-02-01

    In today's high-volume semiconductor world, one could easily take reliability for granted. As the MOEMS/MEMS industry continues to establish itself as a viable alternative to conventional manufacturing in the macro world, reliability can be of high concern. Currently, there are several emerging market opportunities in which MOEMS/MEMS is gaining a foothold. Markets such as mobile media, consumer electronics, biomedical devices, and homeland security are all showing great interest in microfabricated products. At the same time, these markets are among the most demanding when it comes to reliability assurance. To be successful, each company developing a MOEMS/MEMS device must consider reliability on an equal footing with cost, performance and manufacturability. What can this maturing industry learn from the successful development of DLP technology, air bag accelerometers and inkjet printheads? This paper discusses some basic reliability principles which any MOEMS/MEMS device development must use. Examples from the commercially successful and highly reliable Digital Micromirror Device complement the discussion.

  7. PV System 'Availability' as a Reliability Metric -- Improving Standards, Contract Language and Performance Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klise, Geoffrey T.; Hill, Roger; Walker, Andy

    The use of the term 'availability' to describe a photovoltaic (PV) system and power plant has been fraught with confusion for many years. A term that is meant to describe equipment operational status is often omitted, misapplied or inaccurately combined with PV performance metrics due to attempts to measure performance and reliability through the lens of traditional power plant language. This paper discusses three areas where current research in standards, contract language and performance modeling is improving the way availability is used with regards to photovoltaic systems and power plants.

  8. Rendezvous strategy impacts on CTV avionics design, system reliability requirements, and available collision avoidance maneuvers

    NASA Technical Reports Server (NTRS)

    Donovan, William J.; Davis, John E.

    1991-01-01

    Rockwell International is conducting an ongoing program to develop avionics architectures that provide high intrinsic value while meeting all mission objectives. Studies are being conducted to determine alternative configurations that have low life-cycle cost and minimum development risk, and that minimize launch delays while providing the reliability level to assure a successful mission. This effort is based on four decades of providing ballistic missile avionics to the United States Air Force and has focused on the requirements of the NASA Cargo Transfer Vehicle (CTV) program in 1991. During the development of architectural concepts it became apparent that rendezvous strategy issues have an impact on the architecture of the avionics system. This is in addition to the expected impact on propulsion and electrical power duration, flight profiles, and trajectory during approach.

  9. Assessing guilt toward the former spouse.

    PubMed

    Wietzker, Anne; Buysse, Ann

    2012-09-01

    Divorce is often accompanied by feelings of guilt toward the former spouse. So far, no scale has been available to measure such feelings. For this purpose, the authors developed the Guilt in Separation Scale (GiSS). Content validity was assured by using experts and lay experts to generate and select items. Exploratory analyses were run on samples of 214 divorced individuals and confirmatory analyses on 458 individuals who were in the process of divorcing. Evidence was provided for the reliability and construct validity of the GiSS. The internal consistency was high (α = .91), as were the 6-month and 12-month test-retest reliabilities (r = .72 and r = .76, respectively). The GiSS was related to shame, regret, compassion, locus of cause of the separation, unfaithfulness, and psychological functioning. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  10. Nurses' Information Seeking Behavior for Clinical Practice: A Case Study in a Developing Country.

    PubMed

    Sarbaz, Masoumeh; Kimiafar, Khalil; Sheikhtaheri, Abbas; Taherzadeh, Zhila; Eslami, Saeid

    2016-01-01

    We used a valid questionnaire to survey Iranian nurses' seeking information behavior and their confidence on different information sources. The frequently used sources were Internet" and "personal experiences" (54.8% and 48.2% respectively). "English medical journals" (61.9%) and "English textbooks" (41.3%) were the least frequently used sources. Nurses felt high confidence in sources such as "International instructions/guidelines" (58.6%) and "English medical textbooks" (50.4%). The main reasons for selecting sources were easy accessibility, being up to date and reliability. Google, Pubmed and Up to Date were the most used electronic sources. In addition, there were differences in terms of using some of these resources and nurse' age and gender. In developing information sources for nurses, factors such as reliability level, availability, and updatedness of resources should be more emphasized.

  11. The Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM): An assessment of validity, reliability, and responsiveness.

    PubMed

    Bryant, Elizabeth; Murtagh, Shemane; Finucane, Laura; McCrum, Carol; Mercer, Christopher; Smith, Toby; Canby, Guy; Rowe, David A; Moore, Ann P

    2018-05-11

    In response for the need of a freely available, stand-alone, validated outcome measure for use within musculoskeletal (MSK) physiotherapy practice, sensitive enough to measure clinical effectiveness, we developed an MSK patient reported outcome measure. This study examined the validity and reliability of the newly developed Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM) within physiotherapy outpatient settings. Two hundred twenty-four patients attending physiotherapy outpatient departments in South East England with an MSK condition participated in this study. The BmPROM was assessed for user friendliness (rated feedback, N = 224), reliability (internal consistency and test-retest reliability, n = 42), validity (internal and external construct validity, N = 224), and responsiveness (internal, n = 25). Exploratory factor analysis indicated that a two-factor model provides a good fit to the data. Factors were representative of "Functionality" and "Wellbeing". Correlations observed between the BmPROM and SF-36 domains provided evidence of convergent validity. Reliability results indicated that both subscales were internally consistent with alphas above the acceptable limits for both "Functionality" (α = .85, 95% CI [.81, .88]) and 'Wellbeing' (α = .80, 95% CI [.75, .84]). Test-retest analyses (n = 42) demonstrated a high degree of reliability between "Functionality" (ICC = .84; 95% CI [.72, .91]) and "Wellbeing" scores (ICC = .84; 95% CI [.72, .91]). Further examination of test-retest reliability through the Bland-Altman analysis demonstrated that the difference between "Functionality" and "Wellbeing" test scores did not vary as a function of absolute test score. Large treatment effect sizes were found for both subscales (Functionality d = 1.10; Wellbeing 1.03). The BmPROM is a reliable and valid outcome measure for use in evaluating physiotherapy treatment of MSK conditions. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Constructing the 'Best' Reliability Data for the Job - Developing Generic Reliability Data from Alternative Sources Early in a Product's Development Phase

    NASA Technical Reports Server (NTRS)

    Kleinhammer, Roger K.; Graber, Robert R.; DeMott, D. L.

    2016-01-01

    Reliability practitioners advocate getting reliability involved early in a product development process. However, when assigned to estimate or assess the (potential) reliability of a product or system early in the design and development phase, they are faced with lack of reasonable models or methods for useful reliability estimation. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, analysts attempt to develop the "best" or composite analog data to support the assessments. Industries, consortia and vendors across many areas have spent decades collecting, analyzing and tabulating fielded item and component reliability performance in terms of observed failures and operational use. This data resource provides a huge compendium of information for potential use, but can also be compartmented by industry, difficult to find out about, access, or manipulate. One method used incorporates processes for reviewing these existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component. It can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. It also establishes a baseline prior that may updated based on test data or observed operational constraints and failures, i.e., using Bayesian techniques. This tutorial presents a descriptive compilation of historical data sources across numerous industries and disciplines, along with examples of contents and data characteristics. It then presents methods for combining failure information from different sources and mathematical use of this data in early reliability estimation and analyses.

  13. A new approach to power quality and electricity reliability monitoring-case study illustrations of the capabilities of the I-GridTM system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Divan, Deepak; Brumsickle, William; Eto, Joseph

    2003-04-01

    This report describes a new approach for collecting information on power quality and reliability and making it available in the public domain. Making this information readily available in a form that is meaningful to electricity consumers is necessary for enabling more informed private and public decisions regarding electricity reliability. The system dramatically reduces the cost (and expertise) needed for customers to obtain information on the most significant power quality events, called voltage sags and interruptions. The system also offers widespread access to information on power quality collected from multiple sites and the potential for capturing information on the impacts ofmore » power quality problems, together enabling a wide variety of analysis and benchmarking to improve system reliability. Six case studies demonstrate selected functionality and capabilities of the system, including: Linking measured power quality events to process interruption and downtime; Demonstrating the ability to correlate events recorded by multiple monitors to narrow and confirm the causes of power quality events; and Benchmarking power quality and reliability on a firm and regional basis.« less

  14. Methodology and estimation of the welfare impact of energy reforms on households in Azerbaijan

    NASA Astrophysics Data System (ADS)

    Klytchnikova, Irina

    This dissertation develops a new approach that enables policy-makers to analyze welfare gains from improvements in the quality of infrastructure services in developing countries where data are limited and supply is subject to interruptions. An application of the proposed model in the former Soviet Republic of Azerbaijan demonstrates how this approach can be used in welfare assessment of energy sector reforms. The planned reforms in Azerbaijan include a set of measures that will result in a significant improvement in supply reliability, accompanied by a significant increase in the prices of energy services so that they reach the cost recovery level. Currently, households in rural areas receive electricity and gas for only a few hours a day because of a severe deterioration of the energy infrastructure following the collapse of the Soviet Union. The reforms that have recently been initiated will have far-reaching poverty and distributional consequences for the country as they result in an improvement in supply reliability and an increase in energy prices. The new model of intermittent supply developed in this dissertation is based on the household production function approach and draws on previous research in the energy reliability literature. Since modern energy sources (network gas and electricity) in Azerbaijan are cleaner and cheaper than the traditional fuels (fuel wood, etc.), households choose modern fuels whenever they are available. During outages, they rely on traditional fuels. Theoretical welfare measures are derived from a system of fuel demands that takes into account the intermittent availability of energy sources. The model is estimated with the data from the Azerbaijan Household Energy Survey, implemented by the World Bank in December 2003/January 2004. This survey includes an innovative contingent behavior module in which the respondents were asked about their energy consumption patterns in specified reform scenarios. Estimation results strongly indicate that households in the areas with poor supply quality have a high willingness to pay for reliability improvements. However, a relatively small group of households may incur substantial welfare losses from an electricity price increase even when it is combined with a partial reliability improvement. Unlike an earlier assessment of the same reforms in Azerbaijan, analysis in this dissertation clearly shows that targeted investments in improving service reliability may be the best way to mitigate adverse welfare consequences of electricity price increases. Hence, policymakers should focus their attention on ensuring that quality improvements are a central component of power sector reforms. Survey evidence also shows that, although households may incur sizable welfare losses from indoor air pollution when they rely on traditional fuels, they do not recognize indoor air pollution as a factor contributing to the high incidence of respiratory illness among fuel wood users. Therefore, benefits may be greater if policy interventions that improve the reliability of modern energy sources are combined with an information campaign about the adverse health effects of fuel wood use. (Abstract shortened by UMI.)

  15. A review of sex estimation techniques during examination of skeletal remains in forensic anthropology casework.

    PubMed

    Krishan, Kewal; Chatterjee, Preetika M; Kanchan, Tanuj; Kaur, Sandeep; Baryah, Neha; Singh, R K

    2016-04-01

    Sex estimation is considered as one of the essential parameters in forensic anthropology casework, and requires foremost consideration in the examination of skeletal remains. Forensic anthropologists frequently employ morphologic and metric methods for sex estimation of human remains. These methods are still very imperative in identification process in spite of the advent and accomplishment of molecular techniques. A constant boost in the use of imaging techniques in forensic anthropology research has facilitated to derive as well as revise the available population data. These methods however, are less reliable owing to high variance and indistinct landmark details. The present review discusses the reliability and reproducibility of various analytical approaches; morphological, metric, molecular and radiographic methods in sex estimation of skeletal remains. Numerous studies have shown a higher reliability and reproducibility of measurements taken directly on the bones and hence, such direct methods of sex estimation are considered to be more reliable than the other methods. Geometric morphometric (GM) method and Diagnose Sexuelle Probabiliste (DSP) method are emerging as valid methods and widely used techniques in forensic anthropology in terms of accuracy and reliability. Besides, the newer 3D methods are shown to exhibit specific sexual dimorphism patterns not readily revealed by traditional methods. Development of newer and better methodologies for sex estimation as well as re-evaluation of the existing ones will continue in the endeavour of forensic researchers for more accurate results. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Simulated patient training: Using inter-rater reliability to evaluate simulated patient consistency in nursing education.

    PubMed

    MacLean, Sharon; Geddes, Fiona; Kelly, Michelle; Della, Phillip

    2018-03-01

    Simulated patients (SPs) are frequently used for training nursing students in communication skills. An acknowledged benefit of using SPs is the opportunity to provide a standardized approach by which participants can demonstrate and develop communication skills. However, relatively little evidence is available on how to best facilitate and evaluate the reliability and accuracy of SPs' performances. The aim of this study is to investigate the effectiveness of an evidenced based SP training framework to ensure standardization of SPs. The training framework was employed to improve inter-rater reliability of SPs. A quasi-experimental study was employed to assess SP post-training understanding of simulation scenario parameters using inter-rater reliability agreement indices. Two phases of data collection took place. Initially a trial phase including audio-visual (AV) recordings of two undergraduate nursing students completing a simulation scenario is rated by eight SPs using the Interpersonal Communication Assessments Scale (ICAS) and Quality of Discharge Teaching Scale (QDTS). In phase 2, eight SP raters and four nursing faculty raters independently evaluated students' (N=42) communication practices using the QDTS. Intraclass correlation coefficients (ICC) were >0.80 for both stages of the study in clinical communication skills. The results support the premise that if trained appropriately, SPs have a high degree of reliability and validity to both facilitate and evaluate student performance in nurse education. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  17. Reliability and Validity of Athletes Disability Index Questionnaire.

    PubMed

    Noormohammadpour, Pardis; Hosseini Khezri, Alireza; Farahbakhsh, Farzin; Mansournia, Mohammad Ali; Smuck, Matthew; Kordi, Ramin

    2018-03-01

    The purpose of this study was to evaluate validity and reliability of a new proposed questionnaire for assessment of functional disability in athletes with low back pain (LBP). Validity and reliability study. Elite athletes participating in different fields of sports. Participants were 165 male and female athletes (between 12 and 50 years old) with LBP. Athlete Disability Index (ADI) Questionnaire which is developed by the authors for assessing LBP-related disability in athletes, Oswestry Disability Index (ODI), and the Roland-Morris Disability Questionnaire (RDQ). Self-reported responses were collected regarding LBP-related disability through ADI, ODI, and RDQ. The test-retest reliability was strong, and intraclass correlation value ranged between 0.74 and 0.94. The Cronbach alpha coefficient value of 0.91 (P < 0.001) demonstrated excellent internal consistency of the questionnaire. The correlation coefficient between ADI and ODI was r = 0.918 (P < 0.0001), between ADI and RDQ was r = 0.669 (P < 0.0001), and between ADI and visual analog scale was r = 0.626 (P < 0.001). According to ODI and RDQ, disability levels were mild in the large majority of subjects (91.5% and 86.0%, respectively). Alternatively, disability assessments by the ADI did not cluster at the mild level and ranged more broadly from mild to very high. The ADI is a reliable and valid instrument for assessing disability in athletes with LBP. Compared with the available LBP disability questionnaires used in the general population, ADI can more precisely stratify the disability levels of athletes due to LBP.

  18. German version of the Community Balance and Mobility Scale : Translation and evaluation of measurement properties.

    PubMed

    Gordt, Katharina; Mikolaizak, A Stefanie; Nerz, Corinna; Barz, Carolin; Gerhardy, Thomas; Weber, Michaela; Becker, Clemens; Schwenk, Michael

    2018-02-12

    Tools to detect subtle balance deficits in high-functioning community-dwelling older adults are lacking. The Community Balance and Mobility Scale (CBM) is a valuable tool to measure balance deficits in this group; however, it is not yet available in the German language. The aim was 1) to translate and cross-culturally adapt the CBM into the German language and 2) to investigate the measurement properties of the German CBM (G-CBM). The original CBM was translated into the German language according to established guidelines. A total of 51 older adults (mean age 69.9 ± 7.1 years) were recruited to measure construct validity by comparing the G‑CBM against standardized balance and/or mobility assessments including the Fullerton Advanced Balance Scale (FAB), Berg Balance Scale (BBS), 3 m Tandem Walk (3MTW), 8 Level Balance Scale (8LBS), 30 s Chair Stand Test (30CST), Timed Up and Go (TUG) test, gait speed, and the Falls Efficacy Scale International (FES-I). Intrarater and interrater reliability and internal consistency reliability were estimated using intraclass correlations (ICC) and Cronbach's alpha, respectively. Ceiling effects were calculated as the percentage of the sample scoring the maximum score. The G‑CBM correlated excellently with FAB and BBS (ρ = 0.78-0.85; P < 0.001), good with 3MTW, TUG, and FES-I (ρ = -0.55 to -0.61; P < 0.001), and moderately with 8LBS, 30CST, and habitual gait speed (ρ = 0.32-0.46; P < 0.001). Intrarater (ICC 3,k  = 0.998; P < 0.001) and interrater (ICC 2,k  = 0.996; P < 0.001) reliability, and internal consistency reliability (α = 0.998) were also high. The G‑CBM did not show ceiling effects. The G‑CBM is a valid and reliable tool for measuring subtle balance deficits in older high-functioning adults. The absence of ceiling effects emphasizes the use of this scale in this cohort. The G‑CBM can now be utilized in clinical practice.

  19. Understanding Schools as High-Reliability Organizations: An Exploratory Examination of Teachers' and School Leaders' Perceptions of Success

    ERIC Educational Resources Information Center

    Lorton, Juli A.; Bellamy, G. Thomas; Reece, Anne; Carlson, Jill

    2013-01-01

    Drawing on research on high-reliability organizations, this interviewbased qualitative case study employs four characteristics of such organizations as a lens for analyzing the operations of one very successful K-5 public school. Results suggest that the school had processes similar to those characteristic of high-reliability organizations: a…

  20. COMBINE*: An integrated opto-mechanical tool for laser performance modeling

    NASA Astrophysics Data System (ADS)

    Rehak, M.; Di Nicola, J. M.

    2015-02-01

    Accurate modeling of thermal, mechanical and optical processes is important for achieving reliable, high-performance high energy lasers such as those at the National Ignition Facility [1] (NIF). The need for this capability is even more critical for high average power, high repetition rate applications. Modeling the effects of stresses and temperature fields on optical properties allows for optimal design of optical components and more generally of the architecture of the laser system itself. Stresses change the indices of refractions and induce inhomogeneities and anisotropy. We present a modern, integrated analysis tool that efficiently produces reliable results that are used in our laser propagation tools such as VBL [5]. COMBINE is built on and supplants the existing legacy tools developed for the previous generations of lasers at LLNL but also uses commercially available mechanical finite element codes ANSYS or COMSOL (including computational fluid dynamics). The COMBINE code computes birefringence and wave front distortions due to mechanical stresses on lenses and slabs of arbitrary geometry. The stresses calculated typically originate from mounting support, vacuum load, gravity, heat absorption and/or attending cooling. Of particular importance are the depolarization and detuning effects of nonlinear crystals due to thermal loading. Results are given in the form of Jones matrices, depolarization maps and wave front distributions. An incremental evaluation of Jones matrices and ray propagation in a 3D mesh with a stress and temperature field is performed. Wavefront and depolarization maps are available at the optical aperture and at slices within the optical element. The suite is validated, user friendly, supported, documented and amenable to collaborative development. * COMBINE stands for Code for Opto-Mechanical Birefringence Integrated Numerical Evaluations.

  1. RNABindRPlus: a predictor that combines machine learning and sequence homology-based methods to improve the reliability of predicted RNA-binding residues in proteins.

    PubMed

    Walia, Rasna R; Xue, Li C; Wilkins, Katherine; El-Manzalawy, Yasser; Dobbs, Drena; Honavar, Vasant

    2014-01-01

    Protein-RNA interactions are central to essential cellular processes such as protein synthesis and regulation of gene expression and play roles in human infectious and genetic diseases. Reliable identification of protein-RNA interfaces is critical for understanding the structural bases and functional implications of such interactions and for developing effective approaches to rational drug design. Sequence-based computational methods offer a viable, cost-effective way to identify putative RNA-binding residues in RNA-binding proteins. Here we report two novel approaches: (i) HomPRIP, a sequence homology-based method for predicting RNA-binding sites in proteins; (ii) RNABindRPlus, a new method that combines predictions from HomPRIP with those from an optimized Support Vector Machine (SVM) classifier trained on a benchmark dataset of 198 RNA-binding proteins. Although highly reliable, HomPRIP cannot make predictions for the unaligned parts of query proteins and its coverage is limited by the availability of close sequence homologs of the query protein with experimentally determined RNA-binding sites. RNABindRPlus overcomes these limitations. We compared the performance of HomPRIP and RNABindRPlus with that of several state-of-the-art predictors on two test sets, RB44 and RB111. On a subset of proteins for which homologs with experimentally determined interfaces could be reliably identified, HomPRIP outperformed all other methods achieving an MCC of 0.63 on RB44 and 0.83 on RB111. RNABindRPlus was able to predict RNA-binding residues of all proteins in both test sets, achieving an MCC of 0.55 and 0.37, respectively, and outperforming all other methods, including those that make use of structure-derived features of proteins. More importantly, RNABindRPlus outperforms all other methods for any choice of tradeoff between precision and recall. An important advantage of both HomPRIP and RNABindRPlus is that they rely on readily available sequence and sequence-derived features of RNA-binding proteins. A webserver implementation of both methods is freely available at http://einstein.cs.iastate.edu/RNABindRPlus/.

  2. Impact of Device Scaling on Deep Sub-micron Transistor Reliability: A Study of Reliability Trends using SRAM

    NASA Technical Reports Server (NTRS)

    White, Mark; Huang, Bing; Qin, Jin; Gur, Zvi; Talmor, Michael; Chen, Yuan; Heidecker, Jason; Nguyen, Duc; Bernstein, Joseph

    2005-01-01

    As microelectronics are scaled in to the deep sub-micron regime, users of advanced technology CMOS, particularly in high-reliability applications, should reassess how scaling effects impact long-term reliability. An experimental based reliability study of industrial grade SRAMs, consisting of three different technology nodes, is proposed to substantiate current acceleration models for temperature and voltage life-stress relationships. This reliability study utilizes step-stress techniques to evaluate memory technologies (0.25mum, 0.15mum, and 0.13mum) embedded in many of today's high-reliability space/aerospace applications. Two acceleration modeling approaches are presented to relate experimental FIT calculations to Mfr's qualification data.

  3. Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.

    PubMed

    Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart

    2017-10-01

    Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to determine intra- and interobserver reliability, as well as accuracy, efficiency, and precision. Statistical analysis using the intra- and interclass correlation coefficient was calculated using R (version 3.3.2, 2016) to determine the degree of intra- and interobserver reliability. High rates of intra- and interobserver reliability were observed between the junior resident, senior resident, and attending surgeon when using the smartphone protractor application as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.874 respectively. High rates of inter- and intraobserver reliability were also seen between the junior resident, senior resident, and attending surgeon when a marker and protractor were used as demonstrated by high inter- and intra-class correlation coefficients greater than 0.909 and 0.807 respectively. The lumbar lordosis, pelvic incidence, and pelvic tilt values were accurately measured by all three raters, with excellent inter- and intra-class correlation coefficient values. When the first 10 radiographs were re-measured at different time points, a high degree of precision was noted. Measurements performed using the smartphone application were consistently faster than using a marker and protractor-this difference reached statistical significance of p<.05. Adult spinal deformity radiographic parameters can be measured accurately, precisely, reliably, and more efficiently using a smartphone protractor application than with a standard protractor and wax pencil. A high degree of intra- and interobserver reliability was seen between the residents and attending surgeon, indicating measurements made with a smartphone protractor are unaffected by an observer's level of experience. As a result, smartphone protractors may be used when planning ASD surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

    NASA Technical Reports Server (NTRS)

    Sampson, Mike; Brusse, Jay

    2018-01-01

    Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

  5. [NUTRITIONAL STATUS AND BIOCHEMICAL MARKERS OF DEFICIENCY OR EXCESS OF MICRONUTRIENTS IN 4 TO 14 YEAR-OLD CHILEAN CHILDREN: A CRITICAL REVIEW].

    PubMed

    Rozowski Narkunska, Jaime; Castillo Valenzuela, Oscar; Figari Jullian, Nicole; García-Díaz, Diego F; Cruchet Muñoz, Sylvia; Weisstaub Nuta, Gerardo; Pérez-Bravo, Francisco; Gotteland Russel, Martín

    2015-12-01

    The prevalence of obesity in Chilean children has been increasing steadily for the last two decades. The first study to determine nutritional status and food intake in a representative sample of this population was carried out in 1960. Recently the National Food Consumption Survey (ENCA) carried out in 2012 was released by the Ministry of Health. However, this study did not include biochemical determinations of micronutrients which would allow a better diagnosis of nutritional status in children. to review the literature available from 2004 to 2014 in food intake and nutritional status in Chilean children aged 4 to 14 years. a total of 362 references published between 2004 and 2014 were obtained through searches in the databases PubMed, Lilacs, Embase and Scielo. From these, 40 articles were selected for a thorough review. food intake by children is characterized by a high-energy intake, a low consumption of fruits and vegetables and a high consumption of bread. The ENCA showed that 95% of the Chilean population has a deficient diet. A high prevalence of obesity is observed from very early in life. There is a dearth of data available on plasma indicators of vitamin and mineral status since 1960, which would provide more reliable information on nutritional assessment. It is imperative to implement a representative nutrition survey of children in Chile that includes biochemical indicators to get reliable information in order to develop strategies aimed to correct micronutrient malnutrition from excess or deficiency. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  6. Reliability design and verification for launch-vehicle propulsion systems - Report of an AIAA Workshop, Washington, DC, May 16, 17, 1989

    NASA Astrophysics Data System (ADS)

    Launch vehicle propulsion system reliability considerations during the design and verification processes are discussed. The tools available for predicting and minimizing anomalies or failure modes are described and objectives for validating advanced launch system propulsion reliability are listed. Methods for ensuring vehicle/propulsion system interface reliability are examined and improvements in the propulsion system development process are suggested to improve reliability in launch operations. Also, possible approaches to streamline the specification and procurement process are given. It is suggested that government and industry should define reliability program requirements and manage production and operations activities in a manner that provides control over reliability drivers. Also, it is recommended that sufficient funds should be invested in design, development, test, and evaluation processes to ensure that reliability is not inappropriately subordinated to other management considerations.

  7. Incorporating travel-time reliability into the congestion management process : a primer.

    DOT National Transportation Integrated Search

    2015-02-01

    This primer explains the value of incorporating travel-time reliability into the Congestion Management Process (CMP) : and identifies the most current tools available to assist with this effort. It draws from applied research and best practices : fro...

  8. VizieR Online Data Catalog: Herschel nearby isolated low-mass clouds maps (Sadavoy+, 2018)

    NASA Astrophysics Data System (ADS)

    Sadavoy, S. I.; Keto, E.; Bourke, T. L.; Dunham, M. M.; Myers, P. C.; Stephens, I. W.; di, Francesco J.; Webb, K.; Stutz, A. M.; Launhardt, R.; Tobin, J. J.

    2018-05-01

    For all the sources listed in table1, maps of dust temperature and optical depth at 353GHz for all globules as fits files. For all the sources listed in table1, maps of dust temperature, optical depth at 353GHz, and corrected Herschel intensities are available as fits files. The intensity maps contain labels to indicate the reliability of their intensity corrections with Group A as the most reliable, Group B as somewhat reliable, and Group C as least reliable. See paper for details. (3 data files).

  9. Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2015-01-01

    NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.

  10. Potential impact of ZT = 4 thermoelectric materials on solar thermal energy conversion technologies.

    PubMed

    Xie, Ming; Gruen, Dieter M

    2010-11-18

    State-of-the-art methodologies for the conversion of solar thermal power to electricity are based on conventional electromagnetic induction techniques. If appropriate ZT = 4 thermoelectric materials were available, it is likely that conversion efficiencies of 30-40% could be achieved. The availability of all solid state electricity generation would be a long awaited development in part because of the elimination of moving parts. This paper presents a preliminary examination of the potential performance of ZT = 4 power generators in comparison with Stirling engines taking into account specific mass, volume and cost as well as system reliability. High-performance thermoelectrics appear to have distinct advantages over magnetic induction technologies.

  11. Medical image digital archive: a comparison of storage technologies

    NASA Astrophysics Data System (ADS)

    Chunn, Timothy; Hutchings, Matt

    1998-07-01

    A cost effective, high capacity digital archive system is one of the remaining key factors that will enable a radiology department to eliminate film as an archive medium. The ever increasing amount of digital image data is creating the need for huge archive systems that can reliably store and retrieve millions of images and hold from a few terabytes of data to possibly hundreds of terabytes. Selecting the right archive solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, conformance to open standards, archive availability and reliability, security, cost, achievable benefits and cost savings, investment protection, and more. This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. New technologies will be discussed, such as DVD and high performance tape. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on random and pre-fetch retrieval time will be analyzed. The concept of automated migration of images from high performance, RAID disk storage devices to high capacity, NearlineR storage devices will be introduced as a viable way to minimize overall storage costs for an archive.

  12. Climate and Water Vulnerability of the US Electricity Grid Under High Penetrations of Renewable Energy

    NASA Astrophysics Data System (ADS)

    Macknick, J.; Miara, A.; O'Connell, M.; Vorosmarty, C. J.; Newmark, R. L.

    2017-12-01

    The US power sector is highly dependent upon water resources for reliable operations, primarily for thermoelectric cooling and hydropower technologies. Changes in the availability and temperature of water resources can limit electricity generation and cause outages at power plants, which substantially affect grid-level operational decisions. While the effects of water variability and climate changes on individual power plants are well documented, prior studies have not identified the significance of these impacts at the regional systems-level at which the grid operates, including whether there are risks for large-scale blackouts, brownouts, or increases in production costs. Adequately assessing electric grid system-level impacts requires detailed power sector modeling tools that can incorporate electric transmission infrastructure, capacity reserves, and other grid characteristics. Here, we present for the first time, a study of how climate and water variability affect operations of the power sector, considering different electricity sector configurations (low vs. high renewable) and environmental regulations. We use a case study of the US Eastern Interconnection, building off the Eastern Renewable Generation Integration Study (ERGIS) that explored operational challenges of high penetrations of renewable energy on the grid. We evaluate climate-water constraints on individual power plants, using the Thermoelectric Power and Thermal Pollution (TP2M) model coupled with the PLEXOS electricity production cost model, in the context of broader electricity grid operations. Using a five minute time step for future years, we analyze scenarios of 10% to 30% renewable energy penetration along with considerations of river temperature regulations to compare the cost, performance, and reliability tradeoffs of water-dependent thermoelectric generation and variable renewable energy technologies under climate stresses. This work provides novel insights into the resilience and reliability of different configurations of the US electric grid subject to changing climate conditions.

  13. Creating and Sustaining Secondary Schools' Success: Sandfields, Cwmtawe, and the Neath-Port Talbot Local Authority's High Reliability Schools Reform

    ERIC Educational Resources Information Center

    Stringfield, Sam; Reynolds, David; Schaffer, Eugene

    2016-01-01

    This chapter presents data from a 15-year, mixed-methods school improvement effort. The High Reliability Schools (HRS) reform made use of previous research on school effects and on High Reliability Organizations (HROs). HROs are organizations in various parts of our cultures that are required to operate successfully "the first time, every…

  14. Validity and Reliability of the Academic Resilience Scale in Turkish High School

    ERIC Educational Resources Information Center

    Kapikiran, Sahin

    2012-01-01

    The present study aims to determine the validity and reliability of the academic resilience scale in Turkish high school. The participances of the study includes 378 high school students in total (192 female and 186 male). A set of analyses were conducted in order to determine the validity and reliability of the study. Firstly, both exploratory…

  15. Technology Readiness Assessment of Department of Energy Waste Processing Facilities

    DTIC Science & Technology

    2007-09-11

    Must Be Reliable, Robust, Flexible, and Durable 6 EM Is Piloting the TRA/AD2 Process Hanford Waste Treatment Plant ( WTP ) – The Initial Pilot Project...Evaluation WTP can only treat ~ ½ of the LAW in the time it will take to treat all the HLW. • There is a need for tank space that will get more urgent with...Facility before the WTP Pretreatment and High-Level Waste (HLW) Vitrification Facilities are available (Requires tank farm pretreatment capability) TRAs

  16. A High Volume Stack Sampler

    NASA Technical Reports Server (NTRS)

    Boubel, Richard W.

    1971-01-01

    The stack sampler described in this paper has been developed to overcome the difficulties of particulate sampling with presently available equipment. Its use on emissions from hog fuel fired boilers, back-fired incinerators, wigwam burners, asphalt plants, and seed cleaning cyclones is reported. The results indicate that the sampler is rapid and reliable in its use. It is relatively simple and inexpensive to operate. For most sources it should be considered over the more complicated and expensive sampling trains being used and specified.

  17. Automatic non-destructive system for quality assurance of welded elements in the aircraft industry

    NASA Astrophysics Data System (ADS)

    Chady, Tomasz; Waszczuk, Paweł; Szydłowski, Michał; Szwagiel, Mariusz

    2018-04-01

    Flaws that might be a result of the welding process have to be detected, in order to assure high quality thus reliability of elements exploited in aircraft industry. Currently the inspection stage is conducted manually by a qualified workforce. There are no commercially available systems that could support or replace humans in the flaw detection process. In this paper authors present a novel non-destructive system developed for quality assurance purposes of welded elements utilized in the aircraft industry.

  18. Near-Millimeter Wave Technology Base Study: Volume I. Propagation and Target/Background Characteristics

    DTIC Science & Technology

    1979-11-01

    diameter test cell used for laser propagation measurements is Path length-84 m to 2.0 km available and has been designed for circulating aerosols or...36- and 110-GHz and found an attenuation ratio of comparison measurements along a 4-km path with rain rate measured near the receiver end. a *02 They...time. Tipping-bucket systems . gauges are reliable, but become increasingly in- accurate at high rates . Flow gauges which The direct field measurement

  19. Status of the R&D activity on diamond particle detectors

    NASA Astrophysics Data System (ADS)

    Adam, W.; Bellini, B.; Berdermann, E.; Bergonzo, P.; de Boer, W.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Doroshenko, J.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fischer, P.; Fizzotti, F.; Furetta, C.; Gan, K. K.; Ghodbane, N.; Grigoriev, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kaplon, J.; Karl, C.; Kass, R.; Keil, M.; Knöpfle, K. T.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Menichelli, D.; Meuser, S.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Perera, L.; Pernicka, M.; Polesello, P.; Potenza, R.; Riester, J. L.; Roe, S.; Rudge, A.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Sutera, C.; Trischuk, W.; Tromson, D.; Tuve, C.; Weilhammer, P.; Wermes, N.; Wetstein, M.; Zeuner, W.; Zoeller, M.; RD42 Collaboration

    2003-09-01

    Chemical Vapor Deposited (CVD) polycrystalline diamond has been proposed as a radiation-hard alternative to silicon in the extreme radiation levels occurring close to the interaction region of the Large Hadron Collider. Due to an intense research effort, reliable high-quality polycrystalline CVD diamond detectors, with up to 270 μm charge collection distance and good spatial uniformity, are now available. The most recent progress on the diamond quality, on the development of diamond trackers and on radiation hardness studies are presented and discussed.

  20. [Do Multiplex PCR techniques displace classical cultures in microbiology?].

    PubMed

    Auckenthaler, Raymond; Risch, Martin

    2015-02-01

    Multiplex PCR technologies progressively find their way in clinical microbiology. This technique allows the simultaneous amplification of multiple DNA targets in a single test run for the identification of pathogens up to the species level. Various pathogens of infectious diseases can be detected by a symptom-oriented approach clearly and quickly with high reliability. Essentially multiplex PCR panels are available for clarification of gastrointestinal, respiratory, sexually transmitted infections and meningitis. Today's offer from industry, university hospitals and large private laboratories of Switzerland is tabulated and commented.

  1. Paraspinal skin temperature patterns: an interexaminer and intraexaminer reliability study.

    PubMed

    Owens, Edward F; Hart, John F; Donofrio, Joseph J; Haralambous, Jason; Mierzejewski, Eric

    2004-01-01

    Paraspinal thermography is used by chiropractors as an aid in assessing the presence of vertebral subluxation. Few reliability studies have been carried out, with mixed results. Digital infrared scanning equipment is now available with location tracking that may enhance reproducibility. Digitized scans enable a computer-aided interpretation of thermographic patterns. To assess the ability of examiners to reproduce thermal patterns. Repeated measures with 2 examiners assessing the same patient on 2 occasions. Thirty asymptomatic students served as subjects. A TyTron C-3000 handheld thermographic scanner interfaced to a Microsoft Windows compatible personal computer was used for all recordings. Each examiner recorded 2 scans on each patient. It took an average of 3 minutes to complete all 4 scans. Data were exported to a spreadsheet for initial analysis, then SPSS was used for calculation of intraclass correlation coefficients (ICC). Since the starting and stopping points of scans were not always the same, care was taken to align scans visually, using well-distinguished peaks on the charts as guides. Scans were cropped to remove artifacts that might have occurred at the beginning and end of the scans. Intraexaminer and interexaminer ICCs were calculated. Skin temperatures ranged from 35.4 degrees C to 30.0 degrees C over all scans. The average temperatures changed little from the first to the last scans, indicating that subjects' overall skin temperatures were stable during the scanning procedure. Intraexaminer ICCs ranged from 0.953 to 0.984. The left and right channel data show slightly higher congruence than the Delta channel. The interexaminer reliability coefficients ranged from 0.918 to 0.975. Again, the Delta channel shows slightly less reliability, although the ICCs were quite high for all channels. Intraexaminer and interexaminer reliability of paraspinal thermal scans using the TyTron C-3000 were found to be very high, with ICC values between 0.91 and 0.98. Changes seen in thermal scans when properly done are most likely due to actual physiological changes rather than equipment error.

  2. Reliability and validity of generalizable skills instruments for students who are deaf, blind, or visually impaired.

    PubMed

    Loeding, B L; Greenan, J P

    1998-12-01

    The study examined the validity and reliability of four assessments, with three instruments per domain. Domains included generalizable mathematics, communication, interpersonal relations, and reasoning skills. Participants were deaf, legally blind, or visually impaired students enrolled in vocational classes at residential secondary schools. The researchers estimated the internal consistency reliability, test-retest reliability, and construct validity correlations of three subinstruments: student self-ratings, teacher ratings, and performance assessments. The data suggest that these instruments are highly internally consistent measures of generalizable vocational skills. Four performance assessments have high-to-moderate test-retest reliability estimates, and were generally considered to possess acceptable validity and reliability.

  3. The multidriver: A reliable multicast service using the Xpress Transfer Protocol

    NASA Technical Reports Server (NTRS)

    Dempsey, Bert J.; Fenton, John C.; Weaver, Alfred C.

    1990-01-01

    A reliable multicast facility extends traditional point-to-point virtual circuit reliability to one-to-many communication. Such services can provide more efficient use of network resources, a powerful distributed name binding capability, and reduced latency in multidestination message delivery. These benefits will be especially valuable in real-time environments where reliable multicast can enable new applications and increase the availability and the reliability of data and services. We present a unique multicast service that exploits features in the next-generation, real-time transfer layer protocol, the Xpress Transfer Protocol (XTP). In its reliable mode, the service offers error, flow, and rate-controlled multidestination delivery of arbitrary-sized messages, with provision for the coordination of reliable reverse channels. Performance measurements on a single-segment Proteon ProNET-4 4 Mbps 802.5 token ring with heterogeneous nodes are discussed.

  4. Rehabilitative ultrasound imaging of the supraspinatus muscle: Intra- and interrater reliability of thickness and cross-sectional area.

    PubMed

    Schneebeli, Alessandro; Egloff, Michele; Giampietro, Amelia; Clijsen, Ron; Barbero, Marco

    2014-04-01

    To examine intra- and interrater reliability of thickness and cross-sectional area (CSA) measurements of the supraspinatus muscle using rehabilitative ultrasound imaging (RUSI). Two physical therapists acquired b-mode images of the supraspinatus muscles in twenty-five healthy subjects. Thickness and CSA were measured. Intra- and interrater reliability were examined. Intrarater reliability for thickness was high, (ICC1.1 0.91) for rater 1 and (ICC1.1 0.92) for rater 2. Intrarater reliability for CSA was also high, (ICC1.1 0.90) for rater 1 and (ICC1.1 0.85) for rater 2. Interrater reliability for the thickness was high, (ICC3.1 0.86). For CSA, interrater reliability was moderate, (ICC3.1 0.70). Supraspinatus muscle thickness and CSA can be reliably measured by physical therapists in healthy subjects. These findings confirm that RUSI has an interesting potential for physiotherapy clinical practice, especially to assess morphometric changes in skeletal muscles. Further research is needed in subjects with shoulder disorders. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. HitPredict version 4: comprehensive reliability scoring of physical protein-protein interactions from more than 100 species.

    PubMed

    López, Yosvany; Nakai, Kenta; Patil, Ashwini

    2015-01-01

    HitPredict is a consolidated resource of experimentally identified, physical protein-protein interactions with confidence scores to indicate their reliability. The study of genes and their inter-relationships using methods such as network and pathway analysis requires high quality protein-protein interaction information. Extracting reliable interactions from most of the existing databases is challenging because they either contain only a subset of the available interactions, or a mixture of physical, genetic and predicted interactions. Automated integration of interactions is further complicated by varying levels of accuracy of database content and lack of adherence to standard formats. To address these issues, the latest version of HitPredict provides a manually curated dataset of 398 696 physical associations between 70 808 proteins from 105 species. Manual confirmation was used to resolve all issues encountered during data integration. For improved reliability assessment, this version combines a new score derived from the experimental information of the interactions with the original score based on the features of the interacting proteins. The combined interaction score performs better than either of the individual scores in HitPredict as well as the reliability score of another similar database. HitPredict provides a web interface to search proteins and visualize their interactions, and the data can be downloaded for offline analysis. Data usability has been enhanced by mapping protein identifiers across multiple reference databases. Thus, the latest version of HitPredict provides a significantly larger, more reliable and usable dataset of protein-protein interactions from several species for the study of gene groups. Database URL: http://hintdb.hgc.jp/htp. © The Author(s) 2015. Published by Oxford University Press.

  6. English-language videos on YouTube as a source of information on self-administer subcutaneous anti-tumour necrosis factor agent injections.

    PubMed

    Tolu, Sena; Yurdakul, Ozan Volkan; Basaran, Betul; Rezvani, Aylin

    2018-05-14

    The aim of this study was to evaluate the reliability, content, and quality of videos for patients available on YouTube for learning how to self-administer subcutaneous anti-tumour necrosis factor (TNF) injections. We searched for the terms Humira injection, Enbrel injection, Simponi injection, and Cimzia injection. Videos were categorised as useful information, misleading information, useful patient opinion, and misleading patient opinion by two physicians. Videos were rated for quality on a 5-point global quality scale (GQS; 1 = poor quality, 5 = excellent quality) and reliability and content using the 5-point DISCERN scale (higher scores represent greater reliability and more comprehensive videos). Of the 142 English videos, 24 (16.9%) videos were classified as useful information, 6 (4.2%) as misleading information, 47 (33.1%) as useful patient opinion, and 65 (45.8%) as misleading patient opinion. Useful videos were the most comprehensive and had the highest reliability and quality scores. The useful information and useful patient opinion videos had the highest numbers of views per day (median 8.32, IQR: 3.40-14.28 and 5.46, IQR: 3.06-14.44), as compared with 2.32, IQR: 1.63-6.26 for misleading information videos and 2.15, IQR: 1.17-7.43 for misleading patient opinion videos (p = 0.001). Almost all (91.5%) misleading videos were uploaded by individual users. There are a substantial number of English-language YouTube videos, with high quality, and rich content and reliability that can be sources of information on proper technique of anti-TNF self-injections. Physicians should direct patients to the reliable resources of information and educate them in online resource assessment, thereby improving treatment outcomes.

  7. A quick aphasia battery for efficient, reliable, and multidimensional assessment of language function.

    PubMed

    Wilson, Stephen M; Eriksson, Dana K; Schneck, Sarah M; Lucanie, Jillian M

    2018-01-01

    This paper describes a quick aphasia battery (QAB) that aims to provide a reliable and multidimensional assessment of language function in about a quarter of an hour, bridging the gap between comprehensive batteries that are time-consuming to administer, and rapid screening instruments that provide limited detail regarding individual profiles of deficits. The QAB is made up of eight subtests, each comprising sets of items that probe different language domains, vary in difficulty, and are scored with a graded system to maximize the informativeness of each item. From the eight subtests, eight summary measures are derived, which constitute a multidimensional profile of language function, quantifying strengths and weaknesses across core language domains. The QAB was administered to 28 individuals with acute stroke and aphasia, 25 individuals with acute stroke but no aphasia, 16 individuals with chronic post-stroke aphasia, and 14 healthy controls. The patients with chronic post-stroke aphasia were tested 3 times each and scored independently by 2 raters to establish test-retest and inter-rater reliability. The Western Aphasia Battery (WAB) was also administered to these patients to assess concurrent validity. We found that all QAB summary measures were sensitive to aphasic deficits in the two groups with aphasia. All measures showed good or excellent test-retest reliability (overall summary measure: intraclass correlation coefficient (ICC) = 0.98), and excellent inter-rater reliability (overall summary measure: ICC = 0.99). Sensitivity and specificity for diagnosis of aphasia (relative to clinical impression) were 0.91 and 0.95 respectively. All QAB measures were highly correlated with corresponding WAB measures where available. Individual patients showed distinct profiles of spared and impaired function across different language domains. In sum, the QAB efficiently and reliably characterized individual profiles of language deficits.

  8. A quick aphasia battery for efficient, reliable, and multidimensional assessment of language function

    PubMed Central

    Eriksson, Dana K.; Schneck, Sarah M.; Lucanie, Jillian M.

    2018-01-01

    This paper describes a quick aphasia battery (QAB) that aims to provide a reliable and multidimensional assessment of language function in about a quarter of an hour, bridging the gap between comprehensive batteries that are time-consuming to administer, and rapid screening instruments that provide limited detail regarding individual profiles of deficits. The QAB is made up of eight subtests, each comprising sets of items that probe different language domains, vary in difficulty, and are scored with a graded system to maximize the informativeness of each item. From the eight subtests, eight summary measures are derived, which constitute a multidimensional profile of language function, quantifying strengths and weaknesses across core language domains. The QAB was administered to 28 individuals with acute stroke and aphasia, 25 individuals with acute stroke but no aphasia, 16 individuals with chronic post-stroke aphasia, and 14 healthy controls. The patients with chronic post-stroke aphasia were tested 3 times each and scored independently by 2 raters to establish test-retest and inter-rater reliability. The Western Aphasia Battery (WAB) was also administered to these patients to assess concurrent validity. We found that all QAB summary measures were sensitive to aphasic deficits in the two groups with aphasia. All measures showed good or excellent test-retest reliability (overall summary measure: intraclass correlation coefficient (ICC) = 0.98), and excellent inter-rater reliability (overall summary measure: ICC = 0.99). Sensitivity and specificity for diagnosis of aphasia (relative to clinical impression) were 0.91 and 0.95 respectively. All QAB measures were highly correlated with corresponding WAB measures where available. Individual patients showed distinct profiles of spared and impaired function across different language domains. In sum, the QAB efficiently and reliably characterized individual profiles of language deficits. PMID:29425241

  9. Integrating Formal Methods and Testing 2002

    NASA Technical Reports Server (NTRS)

    Cukic, Bojan

    2002-01-01

    Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.

  10. Systems Engineering Provides Successful High Temperature Steam Electrolysis Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charles V. Park; Emmanuel Ohene Opare, Jr.

    2011-06-01

    This paper describes two Systems Engineering Studies completed at the Idaho National Laboratory (INL) to support development of the High Temperature Stream Electrolysis (HTSE) process. HTSE produces hydrogen from water using nuclear power and was selected by the Department of Energy (DOE) for integration with the Next Generation Nuclear Plant (NGNP). The first study was a reliability, availability and maintainability (RAM) analysis to identify critical areas for technology development based on available information regarding expected component performance. An HTSE process baseline flowsheet at commercial scale was used as a basis. The NGNP project also established a process and capability tomore » perform future RAM analyses. The analysis identified which components had the greatest impact on HTSE process availability and indicated that the HTSE process could achieve over 90% availability. The second study developed a series of life-cycle cost estimates for the various scale-ups required to demonstrate the HTSE process. Both studies were useful in identifying near- and long-term efforts necessary for successful HTSE process deployment. The size of demonstrations to support scale-up was refined, which is essential to estimate near- and long-term cost and schedule. The life-cycle funding profile, with high-level allocations, was identified as the program transitions from experiment scale R&D to engineering scale demonstration.« less

  11. Examining the value of travel time reliability for freight transportation to support freight planning and decision-Making [summary].

    DOT National Transportation Integrated Search

    2016-12-01

    As consumers demand greater choice and availability of products, suppliers have responded with more just-in-time delivery and less centralized inventories. Keeping this supply chain working efficiently requires reliable freight transportation. Delays...

  12. Columbus safety and reliability

    NASA Astrophysics Data System (ADS)

    Longhurst, F.; Wessels, H.

    1988-10-01

    Analyses carried out to ensure Columbus reliability, availability, and maintainability, and operational and design safety are summarized. Failure modes/effects/criticality is the main qualitative tool used. The main aspects studied are fault tolerance, hazard consequence control, risk minimization, human error effects, restorability, and safe-life design.

  13. Automated MRI Cerebellar Size Measurements Using Active Appearance Modeling

    PubMed Central

    Price, Mathew; Cardenas, Valerie A.; Fein, George

    2014-01-01

    Although the human cerebellum has been increasingly identified as an important hub that shows potential for helping in the diagnosis of a large spectrum of disorders, such as alcoholism, autism, and fetal alcohol spectrum disorder, the high costs associated with manual segmentation, and low availability of reliable automated cerebellar segmentation tools, has resulted in a limited focus on cerebellar measurement in human neuroimaging studies. We present here the CATK (Cerebellar Analysis Toolkit), which is based on the Bayesian framework implemented in FMRIB’s FIRST. This approach involves training Active Appearance Models (AAM) using hand-delineated examples. CATK can currently delineate the cerebellar hemispheres and three vermal groups (lobules I–V, VI–VII, and VIII–X). Linear registration with the low-resolution MNI152 template is used to provide initial alignment, and Point Distribution Models (PDM) are parameterized using stellar sampling. The Bayesian approach models the relationship between shape and texture through computation of conditionals in the training set. Our method varies from the FIRST framework in that initial fitting is driven by 1D intensity profile matching, and the conditional likelihood function is subsequently used to refine fitting. The method was developed using T1-weighted images from 63 subjects that were imaged and manually labeled: 43 subjects were scanned once and were used for training models, and 20 subjects were imaged twice (with manual labeling applied to both runs) and used to assess reliability and validity. Intraclass correlation analysis shows that CATK is highly reliable (average test-retest ICCs of 0.96), and offers excellent agreement with the gold standard (average validity ICC of 0.87 against manual labels). Comparisons against an alternative atlas-based approach, SUIT (Spatially Unbiased Infratentorial Template), that registers images with a high-resolution template of the cerebellum, show that our AAM approach offers superior reliability and validity. Extensions of CATK to cerebellar hemisphere parcels is envisioned. PMID:25192657

  14. Scale for positive aspects of caregiving experience: development, reliability, and factor structure.

    PubMed

    Kate, N; Grover, S; Kulhara, P; Nehra, R

    2012-06-01

    OBJECTIVE. To develop an instrument (Scale for Positive Aspects of Caregiving Experience [SPACE]) that evaluates positive caregiving experience and assess its psychometric properties. METHODS. Available scales which assess some aspects of positive caregiving experience were reviewed and a 50-item questionnaire with a 5-point rating was constructed. In all, 203 primary caregivers of patients with severe mental disorders were asked to complete the questionnaire. Internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity were evaluated. Principal component factor analysis was run to assess the factorial validity of the scale. RESULTS. The scale developed as part of the study was found to have good internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity. Principal component factor analysis yielded a 4-factor structure, which also had good test-retest reliability and cross-language reliability. There was a strong correlation between the 4 factors obtained. CONCLUSION. The SPACE developed as part of this study has good psychometric properties.

  15. Limiting excessive postoperative blood transfusion after cardiac procedures. A review.

    PubMed Central

    Ferraris, V A; Ferraris, S P

    1995-01-01

    Analysis of blood product use after cardiac operations reveals that a few patients (< or = 20%) consume the majority of blood products (> 80%). The risk factors that predispose a minority of patients to excessive blood use include patient-related factors, transfusion practices, drug-related causes, and procedure-related factors. Multivariate studies suggest that patient age and red blood cell volume are independent patient-related variables that predict excessive blood product transfusion after cardiac procedures. Other factors include preoperative aspirin ingestion, type of operation, over- or underutilization of heparin during cardiopulmonary bypass, failure to correct hypothermia after cardiopulmonary bypass, and physician overtransfusion. A survey of the currently available blood conservation techniques reveals 5 that stand out as reliable methods: 1) high-dose aprotinin therapy, 2) preoperative erythropoietin therapy when time permits adequate dosage before operation, 3) hemodilution by harvest of whole blood immediately before cardiopulmonary bypass, 4) autologous predonation of blood, and 5) salvage of oxygenator blood after cardiopulmonary bypass. Other methods, such as the use of epsilon-aminocaproic acid or desmopressin, cell saving devices, reinfusion of shed mediastinal blood, and hemofiltration have been reported to be less reliable and may even be harmful in some high-risk patients. Consideration of the available data allows formulation of a 4-pronged plan for limiting excessive blood transfusion after surgery: 1) recognize the causes of excessive transfusion, including the importance of red blood cell volume, type of procedure being performed, preoperative aspirin ingestion, etc.; 2) establish a quality management program, including a survey of transfusion practices that emphasizes physician education and availability of real-time laboratory testing to guide transfusion therapy; 3) adopt a multimodal approach using institution-proven techniques; and 4) continually reassess blood product use and analyze the cost-benefits of blood conservation interventions. PMID:7580359

  16. High-precision real-time 3D shape measurement based on a quad-camera system

    NASA Astrophysics Data System (ADS)

    Tao, Tianyang; Chen, Qian; Feng, Shijie; Hu, Yan; Zhang, Minliang; Zuo, Chao

    2018-01-01

    Phase-shifting profilometry (PSP) based 3D shape measurement is well established in various applications due to its high accuracy, simple implementation, and robustness to environmental illumination and surface texture. In PSP, higher depth resolution generally requires higher fringe density of projected patterns which, in turn, lead to severe phase ambiguities that must be solved with additional information from phase coding and/or geometric constraints. However, in order to guarantee the reliability of phase unwrapping, available techniques are usually accompanied by increased number of patterns, reduced amplitude of fringe, and complicated post-processing algorithms. In this work, we demonstrate that by using a quad-camera multi-view fringe projection system and carefully arranging the relative spatial positions between the cameras and the projector, it becomes possible to completely eliminate the phase ambiguities in conventional three-step PSP patterns with high-fringe-density without projecting any additional patterns or embedding any auxiliary signals. Benefiting from the position-optimized quad-camera system, stereo phase unwrapping can be efficiently and reliably performed by flexible phase consistency checks. Besides, redundant information of multiple phase consistency checks is fully used through a weighted phase difference scheme to further enhance the reliability of phase unwrapping. This paper explains the 3D measurement principle and the basic design of quad-camera system, and finally demonstrates that in a large measurement volume of 200 mm × 200 mm × 400 mm, the resultant dynamic 3D sensing system can realize real-time 3D reconstruction at 60 frames per second with a depth precision of 50 μm.

  17. Artificial pancreas (AP) clinical trial participants' acceptance of future AP technology.

    PubMed

    Bevier, Wendy C; Fuller, Serena M; Fuller, Ryan P; Rubin, Richard R; Dassau, Eyal; Doyle, Francis J; Jovanovič, Lois; Zisser, Howard C

    2014-09-01

    Artificial pancreas (AP) systems are currently an active field of diabetes research. This pilot study examined the attitudes of AP clinical trial participants toward future acceptance of the technology, having gained firsthand experience. After possible influencers of AP technology adoption were considered, a 34-question questionnaire was developed. The survey assessed current treatment satisfaction, dimensions of clinical trial participant motivation, and variables of the technology acceptance model (TAM). Forty-seven subjects were contacted to complete the survey. The reliability of the survey scales was tested using Cronbach's α. The relationship of the factors to the likelihood of AP technology adoption was explored using regression analysis. Thirty-six subjects (76.6%) completed the survey. Of the respondents, 86.1% were either highly likely or likely to adopt the technology once available. Reliability analysis of the survey dimensions revealed good internal consistency, with scores of >0.7 for current treatment satisfaction, convenience (motivation), personal health benefit (motivation), perceived ease of use (TAM), and perceived usefulness (TAM). Linear modeling showed that future acceptance of the AP was significantly associated with TAM and the motivation variables of convenience plus the individual item benefit to others (R(2)=0.26, P=0.05). When insulin pump and continuous glucose monitor use were added, the model significance improved (R(2)=0.37, P=0.02). This pilot study demonstrated that individuals with direct AP technology experience expressed high likelihood of future acceptance. Results support the factors of personal benefit, convenience, perceived usefulness, and perceived ease of use as reliable scales that suggest system adoption in this highly motivated patient population.

  18. Present status and future prospects of heavy ion beams as drivers for ICF

    NASA Astrophysics Data System (ADS)

    Godlove, Terry F.

    1986-01-01

    A candidate driver for a practical inertial fusion reactor system must, among other characteristics, be cost effective and reliable for the parameters required by the fusion target and the remainder of the system. Although the history of large particle accelerators provides abundant evidence of their reliability at high repetition rates, their capital cost for the fusion application has been open to question. Attempts to design cost effective systems began with accelerators based on currently available technology such as RF linacs and storage rings. The West German HIBALL and the Japanese HIBLIC are examples of this initial effort. These designs are sufficiently credible that a strong argument can be made for the heavy ion method in general, but to reduce the cost per unit power it was found necessary to design for large scale, hence high capital cost. Emphasis in the U.S. shifted to newer technologies which offer hope of significant improvement in cost. In this paper the status of various heavy ion driver designs are compared with currently perceived requirements in order to illustrate their potential and assess their development needs.

  19. Simultaneous determination of eight major bioactive compounds in Dachengqi Tang (DT) by high-performance liquid chromatography.

    PubMed

    Tang, Wenfu; Wan, Meihua; Zhu, Zhengyan; Chen, Guanyuan; Huang, Xi

    2008-04-29

    Dachengqi Tang (DT) is a common traditional Chinese medicine formula for expelling neire ('internal heat') in the stomach and intestines. There was no reliable analytical method available for the quality control of DT. A high-performance liquid chromatography (HPLC) method with a reverse phase C18 column (150 x 4.6 mm) was developed. The mobile phase was methanol with 0.2% acetic acid. Eight markers including naringin, hesperidin, aloe emodin, rhein, honokiol, magnolol, emodin and chrysophanol were determined. Regression analysis revealed a linear relationship between the concentrations of the markers and the peak area ratio of the standards and internal standard. The limit of detection (S/N = 3) and the limit of qualification (RSD < 20%) ranged from 0.21 to 0.43 ng/microl and 0.76 to 1.74 ng/microl respectively. The recovery was between 95.6% and 103.4%. The tests on the samples from three batches of DT showed that the profiles of the markers did not vary significantly among batches. A reliable HPLC method for simultaneous determination of the eight markers in DT was developed.

  20. Back-bombardment compensation in microwave thermionic electron guns

    NASA Astrophysics Data System (ADS)

    Kowalczyk, Jeremy M. D.; Madey, John M. J.

    2014-12-01

    The development of capable, reliable, and cost-effective compact electron beam sources remains a long-standing objective of the efforts to develop the accelerator systems needed for on-site research and industrial applications ranging from electron beam welding to high performance x-ray and gamma ray light sources for element-resolved microanalysis and national security. The need in these applications for simplicity, reliability, and low cost has emphasized solutions compatible with the use of the long established and commercially available pulsed microwave rf sources and L-, S- or X-band linear accelerators. Thermionic microwave electron guns have proven to be one successful approach to the development of the electron sources for these systems providing high macropulse average current beams with picosecond pulse lengths and good emittance out to macropulse lengths of 4-5 microseconds. But longer macropulse lengths are now needed for use in inverse-Compton x-ray sources and other emerging applications. We describe in this paper our approach to extending the usable macropulse current and pulse length of these guns through the use of thermal diffusion to compensate for the increase in cathode surface temperature due to back-bombardment.

  1. The Bangor Voice Matching Test: A standardized test for the assessment of voice perception ability.

    PubMed

    Mühl, Constanze; Sheil, Orla; Jarutytė, Lina; Bestelmeyer, Patricia E G

    2017-11-09

    Recognising the identity of conspecifics is an important yet highly variable skill. Approximately 2 % of the population suffers from a socially debilitating deficit in face recognition. More recently the existence of a similar deficit in voice perception has emerged (phonagnosia). Face perception tests have been readily available for years, advancing our understanding of underlying mechanisms in face perception. In contrast, voice perception has received less attention, and the construction of standardized voice perception tests has been neglected. Here we report the construction of the first standardized test for voice perception ability. Participants make a same/different identity decision after hearing two voice samples. Item Response Theory guided item selection to ensure the test discriminates between a range of abilities. The test provides a starting point for the systematic exploration of the cognitive and neural mechanisms underlying voice perception. With a high test-retest reliability (r=.86) and short assessment duration (~10 min) this test examines individual abilities reliably and quickly and therefore also has potential for use in developmental and neuropsychological populations.

  2. Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.

    PubMed

    Schwindt, W; Kugel, H; Bachmann, R; Kloska, S; Allkemper, T; Maintz, D; Pfleiderer, B; Tombach, B; Heindel, W

    2003-09-01

    The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting.

  3. Evaluation Applied to Reliability Analysis of Reconfigurable, Highly Reliable, Fault-Tolerant, Computing Systems for Avionics

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques are proposed as a solution to a difficulty arising in the analysis of the reliability of highly reliable computer systems for future commercial aircraft. The difficulty, viz., the lack of credible precision in reliability estimates obtained by analytical modeling techniques are established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible, (2) a complex system design technique, fault tolerance, (3) system reliability dominated by errors due to flaws in the system definition, and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. The technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. The use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques.

  4. Sideband Algorithm for Automatic Wind Turbine Gearbox Fault Detection and Diagnosis: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zappala, D.; Tavner, P.; Crabtree, C.

    2013-01-01

    Improving the availability of wind turbines (WT) is critical to minimize the cost of wind energy, especially for offshore installations. As gearbox downtime has a significant impact on WT availabilities, the development of reliable and cost-effective gearbox condition monitoring systems (CMS) is of great concern to the wind industry. Timely detection and diagnosis of developing gear defects within a gearbox is an essential part of minimizing unplanned downtime of wind turbines. Monitoring signals from WT gearboxes are highly non-stationary as turbine load and speed vary continuously with time. Time-consuming and costly manual handling of large amounts of monitoring data representmore » one of the main limitations of most current CMSs, so automated algorithms are required. This paper presents a fault detection algorithm for incorporation into a commercial CMS for automatic gear fault detection and diagnosis. The algorithm allowed the assessment of gear fault severity by tracking progressive tooth gear damage during variable speed and load operating conditions of the test rig. Results show that the proposed technique proves efficient and reliable for detecting gear damage. Once implemented into WT CMSs, this algorithm can automate data interpretation reducing the quantity of information that WT operators must handle.« less

  5. Technical and Economical Demands on 25K - 77K Refrigerators for Future HTS — Series Products in Power Engineering

    NASA Astrophysics Data System (ADS)

    Gromoll, B.

    2004-06-01

    For the future high temperature superconductivity, HTS, series products new refrigerators are essential. Demands are made on these which are only partly fulfilled by refrigerators available in the market today. This refers to cooling power, initial cost and in particular reliability. Without proper refrigeration techniques it will be almost impossible to bring HTS products to the market. Based on the experiences made by the construction and operation of HTS prototypes within our company, like the 400 kW motor, 1.2 MVA current limiter and 1 MVA traction-transformer provided with refrigerators which are available in the market today, criteria have been established to identify the future technical and economical requirements. These criteria apply to efficiency, maintainability, operation flexibility, feasibility of integration and performance/cost ratio. For the temperature range of 20 K to 77 K cooling with Gifford-McMahon, Pulse Tube, Stirling and Mixture-Cascade refrigerators are applicable. The development potential of these processes are compared for the different applications in future series products. Presented are the necessary steps towards reliable and economic refrigerators from the viewpoint of an equipment manufacturer. These are essential for a market entry in the year 2008.

  6. Brazilian Portuguese version of the Revised Fibromyalgia Impact Questionnaire (FIQR-Br): cross-cultural validation, reliability, and construct and structural validation.

    PubMed

    Lupi, Jaqueline Basilio; Carvalho de Abreu, Daniela Cristina; Ferreira, Mariana Candido; Oliveira, Renê Donizeti Ribeiro de; Chaves, Thais Cristina

    2017-08-01

    This study aimed to culturally adapt and validate the Revised Fibromyalgia Impact Questionnaire (FIQR) to Brazilian Portuguese, by the use of analysis of internal consistency, reliability, and construct and structural validity. A total of 100 female patients with fibromyalgia participated in the validation process of the Brazilian Portuguese version of the FIQR (FIQR-Br).The intraclass correlation coefficient (ICC) was used for statistical analysis of reliability (test-retest), Cronbach's alpha for internal consistency, Pearson's rank correlation for construct validity, and confirmatory factor analysis (CFA) for structural validity. It was verified excellent levels of reliability, with ICC greater than 0.75 for all questions and domains of the FIQR-Br. For internal consistency, alpha values greater than 0.70 for the items and domains of the questionnaire were observed. Moderate (0.40 < r < 0.70) and strong (r > 0.70) correlations were observed for the scores of domains and total score between the FIQR-Br and FIQ-Br. The structure of the three domains of the FIQR-Br was confirmed by CFA. The results of this study suggest that that the FIQR-Br is a reliable and valid instrument for assessing fibromyalgia-related impact, and supports its use in clinical settings and research. The structure of the three domains of the FIQR-Br was also confirmed. Implications for Rehabilitation Fibromyalgia is a chronic musculoskeletal disorder characterized by widespread and diffuse pain, fatigue, sleep disturbances, and depression. The disease significantly impairs patients' quality of life and can be highly disabling. To be used in multicenter research efforts, the Revised Fibromyalgia Impact Questionnaire (FIQR) must be cross-culturally validated and psychometrically tested. This paper will make available a new version of the FIQR-Br since another version already exists, but there are concerns about its measurement properties. The availability of an instrument adapted to and validated for Brazilian Portuguese may make it possible to reliably verify the effects of rehabilitation programs on disability from fibromyalgia. The FIQR-Br showed results comparable with other versions of the FIQR in other languages, thereby enabling comparison of effects of rehabilitation interventions on disability from fibromyalgia conducted in Brazil with results of studies carried out in other parts of the world.

  7. Microgravity

    NASA Image and Video Library

    1992-06-25

    Zeolites are crystalline aluminosilicates that have complex framework structures. However, there are several features of zeolite crystals that make unequivocal structure determinations difficult. The acquisition of reliable structural information on zeolites is greatly facilitated by the availability of high-quality specimens. For structure determinations by conventional diffraction techniques, large single-crystal specimens are essential. Alternatively, structural determinations by powder profile refinement methods relax the constraints on crystal size, but still require materials with a high degree of crystalline perfection. Studies conducted at CAMMP (Center for Advanced Microgravity Materials Processing) have demonstrated that microgravity processing can produce larger crystal sizes and fewer structural defects relative to terrestrial crystal growth. Principal Investigator: Dr. Albert Sacco

  8. Development of small bore, high speed tapered roller bearing

    NASA Technical Reports Server (NTRS)

    Morrison, F. R.; Gassel, S. S.; Bovenkerk, R. L.

    1981-01-01

    The performance of four rolling bearing configurations for use on the input pinion shaft of a proposed commercial helicopter transmission was evaluated. The performance characteristics of a high speed tapered roller bearing operating under conditions comparable to those existing at this input pinion shaft were defined. The tapered roller bearing shaft support configuration was developed for the gearbox using commercially available bearing designings. The configuration was optimized and interactive thermomechanically system analyzed. Automotive pinion quality tapered roller bearings were found to be reliable under load and speed conditions in excess of those anticipated in the helicopter transmission. However, it is indicated that the elastohydrodynamic lubricant films are inadequate.

  9. Zeolites

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Zeolites are crystalline aluminosilicates that have complex framework structures. However, there are several features of zeolite crystals that make unequivocal structure determinations difficult. The acquisition of reliable structural information on zeolites is greatly facilitated by the availability of high-quality specimens. For structure determinations by conventional diffraction techniques, large single-crystal specimens are essential. Alternatively, structural determinations by powder profile refinement methods relax the constraints on crystal size, but still require materials with a high degree of crystalline perfection. Studies conducted at CAMMP (Center for Advanced Microgravity Materials Processing) have demonstrated that microgravity processing can produce larger crystal sizes and fewer structural defects relative to terrestrial crystal growth. Principal Investigator: Dr. Albert Sacco

  10. The discovery and development of HIV therapy: the new challenges.

    PubMed

    Perno, Carlo Federico

    2011-01-01

    The therapy of HIV infection has been dramatically improved over the years, and allowed the achievement of unexpected results. The availability of many drugs, and the knowledge of HIV related pathogenesis, helped in selecting highly effective antiviral therapies, yet today a major challenge stands, that is the selection of the best regimen(s) in clinical practice. In this frame, evidence-based medicine remains a cornerstone of modern medicine, but its structure needs to be adapted to the new challenges, made by an excess of information (not always fully reliable), by highly sophisticated statistical systems that may overlook the clinical practice despite their ability to define the statistical significance, and the limited number of independent controlled studies. The revision of the criteria of evidence-based medicine, and their adaptation to the new tools available, may allow a better contribution to the definition of the best therapy for each single patient.

  11. Reliability and validity of the Safe Routes to school parent and student surveys

    PubMed Central

    2011-01-01

    Background The purpose of this study is to assess the reliability and validity of the U.S. National Center for Safe Routes to School's in-class student travel tallies and written parent surveys. Over 65,000 tallies and 374,000 parent surveys have been completed, but no published studies have examined their measurement properties. Methods Students and parents from two Charlotte, NC (USA) elementary schools participated. Tallies were conducted on two consecutive days using a hand-raising protocol; on day two students were also asked to recall the previous days' travel. The recall from day two was compared with day one to assess 24-hour test-retest reliability. Convergent validity was assessed by comparing parent-reports of students' travel mode with student-reports of travel mode. Two-week test-retest reliability of the parent survey was assessed by comparing within-parent responses. Reliability and validity were assessed using kappa statistics. Results A total of 542 students participated in the in-class student travel tally reliability assessment and 262 parent-student dyads participated in the validity assessment. Reliability was high for travel to and from school (kappa > 0.8); convergent validity was lower but still high (kappa > 0.75). There were no differences by student grade level. Two-week test-retest reliability of the parent survey (n = 112) ranged from moderate to very high for objective questions on travel mode and travel times (kappa range: 0.62 - 0.97) but was substantially lower for subjective assessments of barriers to walking to school (kappa range: 0.31 - 0.76). Conclusions The student in-class student travel tally exhibited high reliability and validity at all elementary grades. The parent survey had high reliability on questions related to student travel mode, but lower reliability for attitudinal questions identifying barriers to walking to school. Parent survey design should be improved so that responses clearly indicate issues that influence parental decision making in regards to their children's mode of travel to school. PMID:21651794

  12. Improving our knowledge of the rapid geomagnetic field intensity variation observed in Europe around 800 AD

    NASA Astrophysics Data System (ADS)

    Gómez-Paccard, M.; Chauvin, A.; Lanos, P.; Dufresne, P.; Kovacheva, M.; Hill, M. J.; Beamud, E.; Gutiérrez-Lloret, S.; Cañavate, V.; Blain, S.; Bouvier, A.; Oberlin, C.; Guibert, P.; Sapin, C.; Pringent, D.

    2011-12-01

    Available European data indicate that during the past 2500 years there have been periods of rapid intensity geomagnetic fluctuations interspersed with periods of little change. The challenge now is to precisely describe these rapid changes. The aim of this study is to obtain an improved description of the sharp geomagnetic intensity change that took place in Western Europe around 800 yrs AD as well as to investigate if this peak is observed at a continental scale. For this purpose 13 precisely dated early medieval Spanish pottery fragments, 4 archeological French kilns and a 3 collections of bricks used for the construction of different historical buildings from France and with ages ranging between 330 to 1290 AD have been studied. The material collected has been dated by archeological/historical constraints together with radiocarbon,thermoluminiscence (TL) and archeomagentic analysis. From classical Thellier experiments including TRM anisotropy and cooling rate corrections upon archeointensity estimates and conducted on 164 specimens (119 of them giving reliable results) ten new high-quality mean intensities have been obtained. The new intensity data together with a selection of the most reliable data from Western Europe have been relocated to the latitude of Paris and confirm the existence of an intensity maxima of ~85 μT centred at ~850 AD and related to intensity changes up to 20 μT per century. The results also indicate that a previous abrupt intensity change (reaching a maximum value of ~ 90 μT) took place in Western Europe around 650 AD. A selection of high-quality intensity data from Bulgaria, Italy and Greece indicate a very similar intensity trend for Eastern Europe. Although available data indicate that the duration of such periods of high intensities may be of less than one century more data are needed to infer the exact duration of these maximums. A comparison between the selected data and regional and global geomagnetic field models indicates that such models fail to reproduce the detailed evolution of geomagnetic intensity changes. These results highlight the need of new reliable and precisely dated archeointensity data if a refined description of geomagnetic field changes wants to be obtained.

  13. High-density carrier-accumulated and electrically stable oxide thin-film transistors from ion-gel gate dielectric

    PubMed Central

    Fujii, Mami N.; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei

    2015-01-01

    The use of indium–gallium–zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic–inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic–inorganic hybrid devices. PMID:26677773

  14. High-density carrier-accumulated and electrically stable oxide thin-film transistors from ion-gel gate dielectric.

    PubMed

    Fujii, Mami N; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei

    2015-12-18

    The use of indium-gallium-zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic-inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic-inorganic hybrid devices.

  15. Reliability of center of pressure measures within and between sessions in individuals post-stroke and healthy controls.

    PubMed

    Gray, Vicki L; Ivanova, Tanya D; Garland, S Jayne

    2014-01-01

    Knowing the reliability of the center of pressure (COP) is important for interpreting balance deficits post-stroke, especially when the balance deficits can necessitate the use of short duration trials. The novel aspect of this reliability study was to examine the center of pressure measures using two adjacent force platforms between and within sessions in stroke and controls. After stroke, it is important to understand the contribution of the paretic and non-paretic leg to the motor control of standing balance. Because there is a considerable body of knowledge on COP reliability on a single platform, we chose to examine reliability using two adjacent platforms which has not been examined previously in stroke. Twenty participants post-stroke and 22 controls performed an arm raise, load drop and quiet stance balance task while standing on two adjacent force platforms, on two separate days. Intraclass correlations coefficient (ICC2,1) and percentage standard error of measurement (SEM%) were calculated for COP velocity, ellipse area, anterior-posterior (AP) displacement, and medial-lateral (ML) displacement. Between sessions, COP velocity was the most reliable with high ICCs and low SEM% across groups and tasks and ellipse area was less reliable with low ICCs across groups and tasks. COP measures were less reliable during the arm raise than load drop post-stroke. Within session reliability was high for COP velocity and ML displacement requiring no more than six trials across tasks. The COP velocity was the most reliable measure with high ICCs between sessions and the high reliability was achieved with fewer trials in both groups in a single session. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. High reliability level on single-mode 980nm-1060 nm diode lasers for telecommunication and industrial applications

    NASA Astrophysics Data System (ADS)

    Van de Casteele, J.; Bettiati, M.; Laruelle, F.; Cargemel, V.; Pagnod-Rossiaux, P.; Garabedian, P.; Raymond, L.; Laffitte, D.; Fromy, S.; Chambonnet, D.; Hirtz, J. P.

    2008-02-01

    We demonstrate very high reliability level on 980-1060nm high-power single-mode lasers through multi-cell tests. First, we show how our chip design and technology enables high reliability levels. Then, we aged 758 devices during 9500 hours among 6 cells with high current (0.8A-1.2A) and high submount temperature (65°C-105°C) for the reliability demonstration. Sudden catastrophic failure is the main degradation mechanism observed. A statistical failure rate model gives an Arrhenius thermal activation energy of 0.51eV and a power law forward current acceleration factor of 5.9. For high-power submarine applications (360mW pump module output optical power), this model exhibits a failure rate as low as 9 FIT at 13°C, while ultra-high power terrestrial modules (600mW) lie below 220 FIT at 25°C. Wear-out phenomena is observed only for very high current level without any reliability impact under 1.1A. For the 1060nm chip, step-stress tests were performed and a set of devices were aged during more than 2000 hours in different stress conditions. First results are in accordance with 980nm product with more than 100khours estimated MTTF. These reliability and performance features of 980-1060nm laser diodes will make high-power single-mode emitters the best choice for a number of telecommunication and industrial applications in the next few years.

  17. Identification of reliable gridded reference data for statistical downscaling methods in Alberta

    NASA Astrophysics Data System (ADS)

    Eum, H. I.; Gupta, A.

    2017-12-01

    Climate models provide essential information to assess impacts of climate change at regional and global scales. However, statistical downscaling methods have been applied to prepare climate model data for various applications such as hydrologic and ecologic modelling at a watershed scale. As the reliability and (spatial and temporal) resolution of statistically downscaled climate data mainly depend on a reference data, identifying the most reliable reference data is crucial for statistical downscaling. A growing number of gridded climate products are available for key climate variables which are main input data to regional modelling systems. However, inconsistencies in these climate products, for example, different combinations of climate variables, varying data domains and data lengths and data accuracy varying with physiographic characteristics of the landscape, have caused significant challenges in selecting the most suitable reference climate data for various environmental studies and modelling. Employing various observation-based daily gridded climate products available in public domain, i.e. thin plate spline regression products (ANUSPLIN and TPS), inverse distance method (Alberta Townships), and numerical climate model (North American Regional Reanalysis) and an optimum interpolation technique (Canadian Precipitation Analysis), this study evaluates the accuracy of the climate products at each grid point by comparing with the Adjusted and Homogenized Canadian Climate Data (AHCCD) observations for precipitation, minimum and maximum temperature over the province of Alberta. Based on the performance of climate products at AHCCD stations, we ranked the reliability of these publically available climate products corresponding to the elevations of stations discretized into several classes. According to the rank of climate products for each elevation class, we identified the most reliable climate products based on the elevation of target points. A web-based system was developed to allow users to easily select the most reliable reference climate data at each target point based on the elevation of grid cell. By constructing the best combination of reference data for the study domain, the accurate and reliable statistically downscaled climate projections could be significantly improved.

  18. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, Eric S.; Campbell, David V.

    1997-01-01

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer.

  19. Evaluation of adding item-response theory analysis for evaluation of the European Board of Ophthalmology Diploma examination.

    PubMed

    Mathysen, Danny G P; Aclimandos, Wagih; Roelant, Ella; Wouters, Kristien; Creuzot-Garcher, Catherine; Ringens, Peter J; Hawlina, Marko; Tassignon, Marie-José

    2013-11-01

    To investigate whether introduction of item-response theory (IRT) analysis, in parallel to the 'traditional' statistical analysis methods available for performance evaluation of multiple T/F items as used in the European Board of Ophthalmology Diploma (EBOD) examination, has proved beneficial, and secondly, to study whether the overall assessment performance of the current written part of EBOD is sufficiently high (KR-20≥ 0.90) to be kept as examination format in future EBOD editions. 'Traditional' analysis methods for individual MCQ item performance comprise P-statistics, Rit-statistics and item discrimination, while overall reliability is evaluated through KR-20 for multiple T/F items. The additional set of statistical analysis methods for the evaluation of EBOD comprises mainly IRT analysis. These analysis techniques are used to monitor whether the introduction of negative marking for incorrect answers (since EBOD 2010) has a positive influence on the statistical performance of EBOD as a whole and its individual test items in particular. Item-response theory analysis demonstrated that item performance parameters should not be evaluated individually, but should be related to one another. Before the introduction of negative marking, the overall EBOD reliability (KR-20) was good though with room for improvement (EBOD 2008: 0.81; EBOD 2009: 0.78). After the introduction of negative marking, the overall reliability of EBOD improved significantly (EBOD 2010: 0.92; EBOD 2011:0.91; EBOD 2012: 0.91). Although many statistical performance parameters are available to evaluate individual items, our study demonstrates that the overall reliability assessment remains the only crucial parameter to be evaluated allowing comparison. While individual item performance analysis is worthwhile to undertake as secondary analysis, drawing final conclusions seems to be more difficult. Performance parameters need to be related, as shown by IRT analysis. Therefore, IRT analysis has proved beneficial for the statistical analysis of EBOD. Introduction of negative marking has led to a significant increase in the reliability (KR-20 > 0.90), indicating that the current examination format can be kept for future EBOD examinations. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. High day-to-day reliability in lower leg volume measured by water displacement.

    PubMed

    Pasley, Jeffrey D; O'Connor, Patrick J

    2008-07-01

    The day-to-day reliability of lower leg volume is poorly documented. This investigation determined the day-to-day reliability of lower leg volume (soleus and gastrocnemius) measured using water displacement. Thirty young adults (15 men and 15 women) had their right lower leg volume measured by water displacement on five separate occasions. The participants performed normal activities of daily living and were measured at the same time of day after being seated for 30 min. The results revealed a high day-to-day reliability for lower leg volume. The mean percentage change in lower leg volume across days compared to day 1 ranged between 0 and 0.37%. The mean within subjects coefficient of variation in lower leg volume was 0.72% and the coefficient of variation for the entire sample across days ranged from 5.66 to 6.32%. A two way mixed model intraclass correlation (30 subjects x 5 days) showed that the lower leg volume measurement was highly reliable (ICC = 0.972). Foot and total lower leg volumes showed similarly high reliability. Water displacement offers a cost effective and reliable solution for the measurement of lower leg edema across days.

  1. Reliability and Validity of a Scale for Rating Memory Impairment in Hospitalized Amnesiacs.

    ERIC Educational Resources Information Center

    Knight, Robert G.; Godfrey, Hamish P. D.

    1984-01-01

    Investigated the reliability and concurrent validity of the Inpatient Memory Impairment Scale (IMIS), using a group of memory-impaired chronic alcoholic and Korsakoff patients (N=20). Analysis revealed that the IMIS had a high degree of internal consistency and that interrater reliability is also high. (LLL)

  2. Performance and Reliability of Bonded Interfaces for High-Temperature Packaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVoto, Douglas

    2016-06-08

    This is a technical review of the DOE VTO EDT project EDT063, Performance and Reliability of Bonded Interfaces for High-Temperature Packaging. A procedure for analyzing the reliability of sintered-silver through experimental thermal cycling and crack propagation modeling has been outlined and results have been presented.

  3. Sexual behaviors among club drug users: prevalence and reliability

    PubMed Central

    Shacham, Enbal; Cottler, Linda B.

    2013-01-01

    HIV prevention efforts require a focus on reducing high risk sexual behavior. Because these are self-reported, assessments that reduce memory bias and improve elicitation of data are needed. As part of a multi-site psychometric study of club drug use, abuse, and dependence, data were collected with a test-retest design that measured the reliability of the Washington University Risk Behavior Assessment for Club Drugs (WU-RBA-CD). Reliability was assessed separately by sex via kappa coefficients and intraclass correlation coefficients (ICC); z tests compared coefficients by sex. A total of 603 participants were interviewed by independent assessors with 5 days in between interviews. Reliability for all 51 items of the sexual activity section of the WU-RBA-CD ranged from .23 to 1.00; 71% (n = 36) of items resulted in moderate to high reliability (.55–1.00). Number of lifetime sex partners was consistently reported for same-sex partners for both men and women and opposite-sex partners. Items with high reliability included reporting ever being under the influence of ecstasy (.87) or GHB (.87) while having sex. Items with lower reliability included those that queried the determinants of condom use (.45–.82) and about behaviors and attitudes experienced while using drugs (.23–.87). Very few sex differences were revealed in the reliability of reported sexual activities. Overall, the WU-RBA-CD performed with fairly high reliability rates. Assessing situations of when, how, and why individuals use condoms may offer the clearest evaluation of determinants of sexual behaviors, yet those items are not as reliable. PMID:19757011

  4. Space propulsion

    NASA Astrophysics Data System (ADS)

    Kazaroff, John M.

    1993-02-01

    Lewis Research Center is developing broad-based new technologies for space chemical engines to satisfy long-term needs of ETO launch vehicles and other vehicles operating in and beyond Earth orbit. Specific objectives are focused on high performance LO2/LH2 engines providing moderate thrusts of 7,5-200 klb. This effort encompasses research related to design analysis and manufacturing processes needed to apply advanced materials to subcomponents, components, and subsystems of space-based systems and related ground-support equipment. High-performance space-based chemical engines face a number of technical challenges. Liquid hydrogen turbopump impellers are often so large that they cannot be machined from a single piece, yet high stress at the vane/shroud interface makes bonding extremely difficult. Tolerances on fillets are critical on large impellers. Advanced materials and fabricating techniques are needed to address these and other issues of interest. Turbopump bearings are needed which can provide reliable, long life operation at high speed and high load with low friction losses. Hydrostatic bearings provide good performance, but transients during pump starts and stops may be an issue because no pressurized fluid is available unless a separate bearing pressurization system is included. Durable materials and/or coatings are needed that can demonstrate low wear in the harsh LO2/LH2 environment. Advanced materials are also needed to improve the lifetime, reliability and performance of other propulsion system elements such as seals and chambers.

  5. Space Transportation System Availability Relationships to Life Cycle Cost

    NASA Technical Reports Server (NTRS)

    Rhodes, Russel E.; Donahue, Benjamin B.; Chen, Timothy T.

    2009-01-01

    Future space transportation architectures and designs must be affordable. Consequently, their Life Cycle Cost (LCC) must be controlled. For the LCC to be controlled, it is necessary to identify all the requirements and elements of the architecture at the beginning of the concept phase. Controlling LCC requires the establishment of the major operational cost drivers. Two of these major cost drivers are reliability and maintainability, in other words, the system's availability (responsiveness). Potential reasons that may drive the inherent availability requirement are the need to control the number of unique parts and the spare parts required to support the transportation system's operation. For more typical space transportation systems used to place satellites in space, the productivity of the system will drive the launch cost. This system productivity is the resultant output of the system availability. Availability is equal to the mean uptime divided by the sum of the mean uptime plus the mean downtime. Since many operational factors cannot be projected early in the definition phase, the focus will be on inherent availability which is equal to the mean time between a failure (MTBF) divided by the MTBF plus the mean time to repair (MTTR) the system. The MTBF is a function of reliability or the expected frequency of failures. When the system experiences failures the result is added operational flow time, parts consumption, and increased labor with an impact to responsiveness resulting in increased LCC. The other function of availability is the MTTR, or maintainability. In other words, how accessible is the failed hardware that requires replacement and what operational functions are required before and after change-out to make the system operable. This paper will describe how the MTTR can be equated to additional labor, additional operational flow time, and additional structural access capability, all of which drive up the LCC. A methodology will be presented that provides the decision makers with the understanding necessary to place constraints on the design definition. This methodology for the major drivers will determine the inherent availability, safety, reliability, maintainability, and the life cycle cost of the fielded system. This methodology will focus on the achievement of an affordable, responsive space transportation system. It is the intent of this paper to not only provide the visibility of the relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability, but also to provide the capability to bound the variables, thus providing the insight required to control the system's engineering solution. An example of this visibility is the need to provide integration of similar discipline functions to allow control of the total parts count of the space transportation system. Also, selecting a reliability requirement will place a constraint on parts count to achieve a given inherent availability requirement, or require accepting a larger parts count with the resulting higher individual part reliability requirements. This paper will provide an understanding of the relationship of mean repair time (mean downtime) to maintainability (accessibility for repair), and both mean time between failure (reliability of hardware) and the system inherent availability.

  6. The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review.

    PubMed

    Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline

    2013-06-01

    What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.

  7. The XMM-SERVS survey: new XMM-Newton point-source catalog for the XMM-LSS field

    NASA Astrophysics Data System (ADS)

    Chen, C.-T. J.; Brandt, W. N.; Luo, B.; Ranalli, P.; Yang, G.; Alexander, D. M.; Bauer, F. E.; Kelson, D. D.; Lacy, M.; Nyland, K.; Tozzi, P.; Vito, F.; Cirasuolo, M.; Gilli, R.; Jarvis, M. J.; Lehmer, B. D.; Paolillo, M.; Schneider, D. P.; Shemmer, O.; Smail, I.; Sun, M.; Tanaka, M.; Vaccari, M.; Vignali, C.; Xue, Y. Q.; Banerji, M.; Chow, K. E.; Häußler, B.; Norris, R. P.; Silverman, J. D.; Trump, J. R.

    2018-04-01

    We present an X-ray point-source catalog from the XMM-Large Scale Structure survey region (XMM-LSS), one of the XMM-Spitzer Extragalactic Representative Volume Survey (XMM-SERVS) fields. We target the XMM-LSS region with 1.3 Ms of new XMM-Newton AO-15 observations, transforming the archival X-ray coverage in this region into a 5.3 deg2 contiguous field with uniform X-ray coverage totaling 2.7 Ms of flare-filtered exposure, with a 46 ks median PN exposure time. We provide an X-ray catalog of 5242 sources detected in the soft (0.5-2 keV), hard (2-10 keV), and/or full (0.5-10 keV) bands with a 1% expected spurious fraction determined from simulations. A total of 2381 new X-ray sources are detected compared to previous source catalogs in the same area. Our survey has flux limits of 1.7 × 10-15, 1.3 × 10-14, and 6.5 × 10-15 erg cm-2 s-1 over 90% of its area in the soft, hard, and full bands, respectively, which is comparable to those of the XMM-COSMOS survey. We identify multiwavelength counterpart candidates for 99.9% of the X-ray sources, of which 93% are considered as reliable based on their matching likelihood ratios. The reliabilities of these high-likelihood-ratio counterparts are further confirmed to be ≈97% reliable based on deep Chandra coverage over ≈5% of the XMM-LSS region. Results of multiwavelength identifications are also included in the source catalog, along with basic optical-to-infrared photometry and spectroscopic redshifts from publicly available surveys. We compute photometric redshifts for X-ray sources in 4.5 deg2 of our field where forced-aperture multi-band photometry is available; >70% of the X-ray sources in this subfield have either spectroscopic or high-quality photometric redshifts.

  8. US Department of Energy`s high-temperature and high-pressure particulate cleanup for advanced coal-based power systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, R.A.

    1997-05-01

    The availability of reliable, low-cost electricity is a cornerstone for the United States` ability to compete in the world market. The Department of Energy (DOE) projects the total consumption of electricity in the US to rise from 2.7 trillion kilowatt-hours in 1990 to 3.5 trillion in 2010. Although energy sources are diversifying, fossil fuel still produces 90 percent of the nation`s energy. Coal is our most abundant fossil fuel resource and the source of 56 percent of our electricity. It has been the fuel of choice because of its availability and low cost. A new generation of high-efficiency power systemsmore » has made it possible to continue the use of coal while still protecting the environment. Such power systems greatly reduce the pollutants associated with cola-fired plants built before the 1970s. To realize this high efficiency and superior environmental performance, advanced coal-based power systems will require gas stream cleanup under high-temperature and high-pressure (HTHP) process conditions. Presented in this paper are the HTHP particulate capture requirements for the Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized-Bed Combustion (PFBC) power systems, the HTHP particulate cleanup systems being implemented in the PFBC and IGCC Clean Coal Technology (CCT) Projects, and the currently available particulate capture performance results.« less

  9. Evaluation methodologies for an advanced information processing system

    NASA Technical Reports Server (NTRS)

    Schabowsky, R. S., Jr.; Gai, E.; Walker, B. K.; Lala, J. H.; Motyka, P.

    1984-01-01

    The system concept and requirements for an Advanced Information Processing System (AIPS) are briefly described, but the emphasis of this paper is on the evaluation methodologies being developed and utilized in the AIPS program. The evaluation tasks include hardware reliability, maintainability and availability, software reliability, performance, and performability. Hardware RMA and software reliability are addressed with Markov modeling techniques. The performance analysis for AIPS is based on queueing theory. Performability is a measure of merit which combines system reliability and performance measures. The probability laws of the performance measures are obtained from the Markov reliability models. Scalar functions of this law such as the mean and variance provide measures of merit in the AIPS performability evaluations.

  10. Flight control electronics reliability/maintenance study

    NASA Technical Reports Server (NTRS)

    Dade, W. W.; Edwards, R. H.; Katt, G. T.; Mcclellan, K. L.; Shomber, H. A.

    1977-01-01

    Collection and analysis of data are reported that concern the reliability and maintenance experience of flight control system electronics currently in use on passenger carrying jet aircraft. Two airlines B-747 airplane fleets were analyzed to assess the component reliability, system functional reliability, and achieved availability of the CAT II configuration flight control system. Also assessed were the costs generated by this system in the categories of spare equipment, schedule irregularity, and line and shop maintenance. The results indicate that although there is a marked difference in the geographic location and route pattern between the airlines studied, there is a close similarity in the reliability and the maintenance costs associated with the flight control electronics.

  11. Parts and Components Reliability Assessment: A Cost Effective Approach

    NASA Technical Reports Server (NTRS)

    Lee, Lydia

    2009-01-01

    System reliability assessment is a methodology which incorporates reliability analyses performed at parts and components level such as Reliability Prediction, Failure Modes and Effects Analysis (FMEA) and Fault Tree Analysis (FTA) to assess risks, perform design tradeoffs, and therefore, to ensure effective productivity and/or mission success. The system reliability is used to optimize the product design to accommodate today?s mandated budget, manpower, and schedule constraints. Stand ard based reliability assessment is an effective approach consisting of reliability predictions together with other reliability analyses for electronic, electrical, and electro-mechanical (EEE) complex parts and components of large systems based on failure rate estimates published by the United States (U.S.) military or commercial standards and handbooks. Many of these standards are globally accepted and recognized. The reliability assessment is especially useful during the initial stages when the system design is still in the development and hard failure data is not yet available or manufacturers are not contractually obliged by their customers to publish the reliability estimates/predictions for their parts and components. This paper presents a methodology to assess system reliability using parts and components reliability estimates to ensure effective productivity and/or mission success in an efficient manner, low cost, and tight schedule.

  12. The demise of plastic encapsulated microcircuit myths

    NASA Astrophysics Data System (ADS)

    Hakim, E. B.; Agarwal, R. K.; Pecht, M.

    1994-10-01

    Production of microelectronic devices encapsulated in solid, molded plastic packages has rapidly increased since the early 1980's. Today, millions of plastic-encapsulated devices are produced daily. On the other hand, only a few million hermetic (cavity) packages are produced per year. Reasons for the increased use of plastic-encapsulated packages include cost, availability, size, weight, quality, and reliability. Markets taking advantage of this technology range from computers and telecommunications to automotive uses. Yet, several industries, the military in particular, will not accept such devices. One reason for this reluctance to use the best available commercial parts is a perceived risk of poor reliability, derived from antiquated military specifications, standards, and handbooks; other common justifications cite differing environments; inadequate screens; inadequate test data, and required government audits of suppliers' processes. This paper describes failure mechanisms associated with plastic encapsulation and their elimination. It provides data indicating the relative reliability of cavity and solid-encapsulated packaging, and presents possible approaches to assuring quality and reliability in the procuring and applying this successful commercial technology.

  13. Evolving Reliability and Maintainability Allocations for NASA Ground Systems

    NASA Technical Reports Server (NTRS)

    Munoz, Gisela; Toon, T.; Toon, J.; Conner, A.; Adams, T.; Miranda, D.

    2016-01-01

    This paper describes the methodology and value of modifying allocations to reliability and maintainability requirements for the NASA Ground Systems Development and Operations (GSDO) programs subsystems. As systems progressed through their design life cycle and hardware data became available, it became necessary to reexamine the previously derived allocations. This iterative process provided an opportunity for the reliability engineering team to reevaluate allocations as systems moved beyond their conceptual and preliminary design phases. These new allocations are based on updated designs and maintainability characteristics of the components. It was found that trade-offs in reliability and maintainability were essential to ensuring the integrity of the reliability and maintainability analysis. This paper discusses the results of reliability and maintainability reallocations made for the GSDO subsystems as the program nears the end of its design phase.

  14. Evolving Reliability and Maintainability Allocations for NASA Ground Systems

    NASA Technical Reports Server (NTRS)

    Munoz, Gisela; Toon, Troy; Toon, Jamie; Conner, Angelo C.; Adams, Timothy C.; Miranda, David J.

    2016-01-01

    This paper describes the methodology and value of modifying allocations to reliability and maintainability requirements for the NASA Ground Systems Development and Operations (GSDO) program’s subsystems. As systems progressed through their design life cycle and hardware data became available, it became necessary to reexamine the previously derived allocations. This iterative process provided an opportunity for the reliability engineering team to reevaluate allocations as systems moved beyond their conceptual and preliminary design phases. These new allocations are based on updated designs and maintainability characteristics of the components. It was found that trade-offs in reliability and maintainability were essential to ensuring the integrity of the reliability and maintainability analysis. This paper discusses the results of reliability and maintainability reallocations made for the GSDO subsystems as the program nears the end of its design phase.

  15. Evolving Reliability and Maintainability Allocations for NASA Ground Systems

    NASA Technical Reports Server (NTRS)

    Munoz, Gisela; Toon, Jamie; Toon, Troy; Adams, Timothy C.; Miranda, David J.

    2016-01-01

    This paper describes the methodology that was developed to allocate reliability and maintainability requirements for the NASA Ground Systems Development and Operations (GSDO) program's subsystems. As systems progressed through their design life cycle and hardware data became available, it became necessary to reexamine the previously derived allocations. Allocating is an iterative process; as systems moved beyond their conceptual and preliminary design phases this provided an opportunity for the reliability engineering team to reevaluate allocations based on updated designs and maintainability characteristics of the components. Trade-offs in reliability and maintainability were essential to ensuring the integrity of the reliability and maintainability analysis. This paper will discuss the value of modifying reliability and maintainability allocations made for the GSDO subsystems as the program nears the end of its design phase.

  16. Flower power: tree flowering phenology as a settlement cue for migrating birds.

    PubMed

    McGrath, Laura J; van Riper, Charles; Fontaine, Joseph J

    2009-01-01

    1. Neotropical migrant birds show a clear preference for stopover habitats with ample food supplies; yet, the proximate cues underlying these decisions remain unclear. 2. For insectivorous migrants, cues associated with vegetative phenology (e.g. flowering, leaf flush, and leaf loss) may reliably predict the availability of herbivorous arthropods. Here we examined whether migrants use the phenology of five tree species to choose stopover locations, and whether phenology accurately predicts food availability. 3. Using a combination of experimental and observational evidence, we show migrant populations closely track tree phenology, particularly the flowering phenology of honey mesquite (Prosopis glandulosa), and preferentially forage in trees with more flowers. Furthermore, the flowering phenology of honey mesquite reliably predicts overall arthropod abundance as well as the arthropods preferred by migrants for food. 4. Together, these results suggest that honey mesquite flowering phenology is an important cue used by migrants to assess food availability quickly and reliably, while in transit during spring migration.

  17. Flower power: Tree flowering phenology as a settlement cue for migrating birds

    USGS Publications Warehouse

    McGrath, L.J.; van Riper, Charles; Fontaine, J.J.

    2009-01-01

    1. Neotropical migrant birds show a clear preference for stopover habitats with ample food supplies; yet, the proximate cues underlying these decisions remain unclear. 2. For insectivorous migrants, cues associated with vegetative phenology (e.g. flowering, leaf flush, and leaf loss) may reliably predict the availability of herbivorous arthropods. Here we examined whether migrants use the phenology of five tree species to choose stopover locations, and whether phenology accurately predicts food availability. 3. Using a combination of experimental and observational evidence, we show migrant populations closely track tree phenology, particularly the flowering phenology of honey mesquite (Prosopis glandulosa), and preferentially forage in trees with more flowers. Furthermore, the flowering phenology of honey mesquite reliably predicts overall arthropod abundance as well as the arthropods preferred by migrants for food. 4. Together, these results suggest that honey mesquite flowering phenology is an important cue used by migrants to assess food availability quickly and reliably, while in transit during spring migration. ?? 2008 The Authors.

  18. Teamwork as an Essential Component of High-Reliability Organizations

    PubMed Central

    Baker, David P; Day, Rachel; Salas, Eduardo

    2006-01-01

    Organizations are increasingly becoming dynamic and unstable. This evolution has given rise to greater reliance on teams and increased complexity in terms of team composition, skills required, and degree of risk involved. High-reliability organizations (HROs) are those that exist in such hazardous environments where the consequences of errors are high, but the occurrence of error is extremely low. In this article, we argue that teamwork is an essential component of achieving high reliability particularly in health care organizations. We describe the fundamental characteristics of teams, review strategies in team training, demonstrate the criticality of teamwork in HROs and finally, identify specific challenges the health care community must address to improve teamwork and enhance reliability. PMID:16898980

  19. Design of high reliability organizations in health care.

    PubMed

    Carroll, J S; Rudolph, J W

    2006-12-01

    To improve safety performance, many healthcare organizations have sought to emulate high reliability organizations from industries such as nuclear power, chemical processing, and military operations. We outline high reliability design principles for healthcare organizations including both the formal structures and the informal practices that complement those structures. A stage model of organizational structures and practices, moving from local autonomy to formal controls to open inquiry to deep self-understanding, is used to illustrate typical challenges and design possibilities at each stage. We suggest how organizations can use the concepts and examples presented to increase their capacity to self-design for safety and reliability.

  20. Multiprocessor switch with selective pairing

    DOEpatents

    Gara, Alan; Gschwind, Michael K; Salapura, Valentina

    2014-03-11

    System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switch or a bus

  1. Scheduler for multiprocessor system switch with selective pairing

    DOEpatents

    Gara, Alan; Gschwind, Michael Karl; Salapura, Valentina

    2015-01-06

    System, method and computer program product for scheduling threads in a multiprocessing system with selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). The method configures the selective pairing facility to use checking provide one highly reliable thread for high-reliability and allocate threads to corresponding processor cores indicating need for hardware checking. The method configures the selective pairing facility to provide multiple independent cores and allocate threads to corresponding processor cores indicating inherent resilience.

  2. Software reliability through fault-avoidance and fault-tolerance

    NASA Technical Reports Server (NTRS)

    Vouk, Mladen A.; Mcallister, David F.

    1993-01-01

    Strategies and tools for the testing, risk assessment and risk control of dependable software-based systems were developed. Part of this project consists of studies to enable the transfer of technology to industry, for example the risk management techniques for safety-concious systems. Theoretical investigations of Boolean and Relational Operator (BRO) testing strategy were conducted for condition-based testing. The Basic Graph Generation and Analysis tool (BGG) was extended to fully incorporate several variants of the BRO metric. Single- and multi-phase risk, coverage and time-based models are being developed to provide additional theoretical and empirical basis for estimation of the reliability and availability of large, highly dependable software. A model for software process and risk management was developed. The use of cause-effect graphing for software specification and validation was investigated. Lastly, advanced software fault-tolerance models were studied to provide alternatives and improvements in situations where simple software fault-tolerance strategies break down.

  3. Burst Mode ASIC-Based Modem

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The NASA Lewis Research Center is sponsoring the Advanced Communication Technology Insertion (ACTION) for Commercial Space Applications program. The goal of the program is to expedite the development of new technology with a clear path towards productization and enhancing the competitiveness of U.S. manufacturers. The industry has made significant investment in developing ASIC-based modem technology for continuous-mode applications and has made investigations into East, reliable acquisition of burst-mode digital communication signals. With rapid advances in analog and digital communications ICs, it is expected that more functions will be integrated onto these parts in the near future. In addition custom ASIC's can also be developed to address the areas not covered by the other IC's. Using the commercial chips and custom ASIC's, lower-cost, compact, reliable, and high-performance modems can be built for demanding satellite communication application. This report outlines a frequency-hop burst modem design based on commercially available chips.

  4. Application of exercise ECG stress test in the current high cost modern-era healthcare system.

    PubMed

    Vaidya, Gaurang Nandkishor

    Exercise electrocardiogram (ECG) tests boasts of being more widely available, less resource intensive, lower cost and absence of radiation. In the presence of a normal baseline ECG, an exercise ECG test is able to generate a reliable and reproducible result almost comparable to Technitium-99m sestamibi perfusion imaging. Exercise ECG changes when combined with other clinical parameters obtained during the test has the potential to allow effective redistribution of scarce resources by excluding low risk patients with significant accuracy. As we look towards a future of rising healthcare costs, increased prevalence of cardiovascular disease and the need for proper allocation of limited resources; exercise ECG test offers low cost, vital and reliable disease interpretation. This article highlights the physiology of the exercise ECG test, patient selection, effective interpretation, describe previously reported scores and their clinical application in today's clinical practice. Copyright © 2017. Published by Elsevier B.V.

  5. Reliable Adaptive Video Streaming Driven by Perceptual Semantics for Situational Awareness

    PubMed Central

    Pimentel-Niño, M. A.; Saxena, Paresh; Vazquez-Castro, M. A.

    2015-01-01

    A novel cross-layer optimized video adaptation driven by perceptual semantics is presented. The design target is streamed live video to enhance situational awareness in challenging communications conditions. Conventional solutions for recreational applications are inadequate and novel quality of experience (QoE) framework is proposed which allows fully controlled adaptation and enables perceptual semantic feedback. The framework relies on temporal/spatial abstraction for video applications serving beyond recreational purposes. An underlying cross-layer optimization technique takes into account feedback on network congestion (time) and erasures (space) to best distribute available (scarce) bandwidth. Systematic random linear network coding (SRNC) adds reliability while preserving perceptual semantics. Objective metrics of the perceptual features in QoE show homogeneous high performance when using the proposed scheme. Finally, the proposed scheme is in line with content-aware trends, by complying with information-centric-networking philosophy and architecture. PMID:26247057

  6. Development and Validity Testing of the Worksite Health Index: An Assessment Tool to Help and Improve Korean Employees' Health-Related Outcome.

    PubMed

    Yun, Young Ho; Sim, Jin Ah; Lim, Ye Jin; Lim, Cheol Il; Kang, Sung-Choon; Kang, Joon-Ho; Park, Jun Dong; Noh, Dong Young

    2016-06-01

    The objective of this study was to develop the Worksite Health Index (WHI) and validate its psychometric properties. The development of the WHI questionnaire included item generation, item construction, and field testing. To assess the instrument's reliability and validity, we recruited 30 different Korean worksites. We developed the WHI questionnaire of 136 items categorized into five domains, namely Governance and Infrastructure, Need Assessment and Planning, Health Prevention and Promotion Program, Occupational Safety, and Monitoring and Feedback. All WHI domains demonstrated a high reliability with good internal consistency. The total WHI scores differentiated worksite groups effectively according to firm size. Each domain was associated significantly with employees' health status, absence, and financial outcome. The WHI can assess comprehensive worksite health programs. This tool is publicly available for addressing the growing need for worksite health programs.

  7. Reliability Quantification of Advanced Stirling Convertor (ASC) Components

    NASA Technical Reports Server (NTRS)

    Shah, Ashwin R.; Korovaichuk, Igor; Zampino, Edward

    2010-01-01

    The Advanced Stirling Convertor, is intended to provide power for an unmanned planetary spacecraft and has an operational life requirement of 17 years. Over this 17 year mission, the ASC must provide power with desired performance and efficiency and require no corrective maintenance. Reliability demonstration testing for the ASC was found to be very limited due to schedule and resource constraints. Reliability demonstration must involve the application of analysis, system and component level testing, and simulation models, taken collectively. Therefore, computer simulation with limited test data verification is a viable approach to assess the reliability of ASC components. This approach is based on physics-of-failure mechanisms and involves the relationship among the design variables based on physics, mechanics, material behavior models, interaction of different components and their respective disciplines such as structures, materials, fluid, thermal, mechanical, electrical, etc. In addition, these models are based on the available test data, which can be updated, and analysis refined as more data and information becomes available. The failure mechanisms and causes of failure are included in the analysis, especially in light of the new information, in order to develop guidelines to improve design reliability and better operating controls to reduce the probability of failure. Quantified reliability assessment based on fundamental physical behavior of components and their relationship with other components has demonstrated itself to be a superior technique to conventional reliability approaches based on utilizing failure rates derived from similar equipment or simply expert judgment.

  8. Evaluating Written Patient Information for Eczema in German: Comparing the Reliability of Two Instruments, DISCERN and EQIP

    PubMed Central

    McCool, Megan E.; Wahl, Josepha; Schlecht, Inga; Apfelbacher, Christian

    2015-01-01

    Patients actively seek information about how to cope with their health problems, but the quality of the information available varies. A number of instruments have been developed to assess the quality of patient information, primarily though in English. Little is known about the reliability of these instruments when applied to patient information in German. The objective of our study was to investigate and compare the reliability of two validated instruments, DISCERN and EQIP, in order to determine which of these instruments is better suited for a further study pertaining to the quality of information available to German patients with eczema. Two independent raters evaluated a random sample of 20 informational brochures in German. All the brochures addressed eczema as a disorder and/or therapy options and care. Intra-rater and inter-rater reliability were assessed by calculating intra-class correlation coefficients, agreement was tested with weighted kappas, and the correlation of the raters’ scores for each instrument was measured with Pearson’s correlation coefficient. DISCERN demonstrated substantial intra- and inter-rater reliability. It also showed slightly better agreement than EQIP. There was a strong correlation of the raters’ scores for both instruments. The findings of this study support the reliability of both DISCERN and EQIP. However, based on the results of the inter-rater reliability, agreement and correlation analyses, we consider DISCERN to be the more precise tool for our project on patient information concerning the treatment and care of eczema. PMID:26440612

  9. Evaluating Written Patient Information for Eczema in German: Comparing the Reliability of Two Instruments, DISCERN and EQIP.

    PubMed

    McCool, Megan E; Wahl, Josepha; Schlecht, Inga; Apfelbacher, Christian

    2015-01-01

    Patients actively seek information about how to cope with their health problems, but the quality of the information available varies. A number of instruments have been developed to assess the quality of patient information, primarily though in English. Little is known about the reliability of these instruments when applied to patient information in German. The objective of our study was to investigate and compare the reliability of two validated instruments, DISCERN and EQIP, in order to determine which of these instruments is better suited for a further study pertaining to the quality of information available to German patients with eczema. Two independent raters evaluated a random sample of 20 informational brochures in German. All the brochures addressed eczema as a disorder and/or therapy options and care. Intra-rater and inter-rater reliability were assessed by calculating intra-class correlation coefficients, agreement was tested with weighted kappas, and the correlation of the raters' scores for each instrument was measured with Pearson's correlation coefficient. DISCERN demonstrated substantial intra- and inter-rater reliability. It also showed slightly better agreement than EQIP. There was a strong correlation of the raters' scores for both instruments. The findings of this study support the reliability of both DISCERN and EQIP. However, based on the results of the inter-rater reliability, agreement and correlation analyses, we consider DISCERN to be the more precise tool for our project on patient information concerning the treatment and care of eczema.

  10. To what extent do they sway Australian water management decision making?

    NASA Astrophysics Data System (ADS)

    Papas, Maureen

    2016-10-01

    At a time when the reliability of freshwater resources has become highly unpredictable, as a result of climate change and increased droughts frequency, the role of scientific evidence in forecasting the availability of seasonal water has become more critical. Australia is one of the driest inhabited continents. Its freshwater availability is highly variable, which poses unique problems for the management of the nation's water resources. Under Australia's federal system, water management challenges have been progressively dealt with through political institutions that rely on best available science to inform policy development. However, it could be argued that evidenced-based policy making is an impossible aim in a highly complex and uncertain political environment: that such a rational approach would be defeated by competing values and vested interests across stakeholders. This article demonstrates that, while science has a fundamental role to play in effective water resource management, the reality on the ground often diverges from the intended aim and does not always reflect efforts at reform. This article briefly reviews the Water Act 2007 (Cth) and comments on why policy makers need to manage rather than try to eliminate uncertainty to promote change.

  11. Establishing Inter- and Intrarater Reliability for High-Stakes Testing Using Simulation.

    PubMed

    Kardong-Edgren, Suzan; Oermann, Marilyn H; Rizzolo, Mary Anne; Odom-Maryon, Tamara

    This article reports one method to develop a standardized training method to establish the inter- and intrarater reliability of a group of raters for high-stakes testing. Simulation is used increasingly for high-stakes testing, but without research into the development of inter- and intrarater reliability for raters. Eleven raters were trained using a standardized methodology. Raters scored 28 student videos over a six-week period. Raters then rescored all videos over a two-day period to establish both intra- and interrater reliability. One rater demonstrated poor intrarater reliability; a second rater failed all students. Kappa statistics improved from the moderate to substantial agreement range with the exclusion of the two outlier raters' scores. There may be faculty who, for different reasons, should not be included in high-stakes testing evaluations. All faculty are content experts, but not all are expert evaluators.

  12. Achieving High Reliability with People, Processes, and Technology.

    PubMed

    Saunders, Candice L; Brennan, John A

    2017-01-01

    High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.

  13. Assessing Variations in Areal Organization for the Intrinsic Brain: From Fingerprints to Reliability

    PubMed Central

    Xu, Ting; Opitz, Alexander; Craddock, R. Cameron; Wright, Margaret J.; Zuo, Xi-Nian; Milham, Michael P.

    2016-01-01

    Resting state fMRI (R-fMRI) is a powerful in-vivo tool for examining the functional architecture of the human brain. Recent studies have demonstrated the ability to characterize transitions between functionally distinct cortical areas through the mapping of gradients in intrinsic functional connectivity (iFC) profiles. To date, this novel approach has primarily been applied to iFC profiles averaged across groups of individuals, or in one case, a single individual scanned multiple times. Here, we used a publically available R-fMRI dataset, in which 30 healthy participants were scanned 10 times (10 min per session), to investigate differences in full-brain transition profiles (i.e., gradient maps, edge maps) across individuals, and their reliability. 10-min R-fMRI scans were sufficient to achieve high accuracies in efforts to “fingerprint” individuals based upon full-brain transition profiles. Regarding test–retest reliability, the image-wise intraclass correlation coefficient (ICC) was moderate, and vertex-level ICC varied depending on region; larger durations of data yielded higher reliability scores universally. Initial application of gradient-based methodologies to a recently published dataset obtained from twins suggested inter-individual variation in areal profiles might have genetic and familial origins. Overall, these results illustrate the utility of gradient-based iFC approaches for studying inter-individual variation in brain function. PMID:27600846

  14. Methods and Costs to Achieve Ultra Reliable Life Support

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2012-01-01

    A published Mars mission is used to explore the methods and costs to achieve ultra reliable life support. The Mars mission and its recycling life support design are described. The life support systems were made triply redundant, implying that each individual system will have fairly good reliability. Ultra reliable life support is needed for Mars and other long, distant missions. Current systems apparently have insufficient reliability. The life cycle cost of the Mars life support system is estimated. Reliability can be increased by improving the intrinsic system reliability, adding spare parts, or by providing technically diverse redundant systems. The costs of these approaches are estimated. Adding spares is least costly but may be defeated by common cause failures. Using two technically diverse systems is effective but doubles the life cycle cost. Achieving ultra reliability is worth its high cost because the penalty for failure is very high.

  15. The Queensland high risk foot form (QHRFF) – is it a reliable and valid clinical research tool for foot disease?

    PubMed Central

    2014-01-01

    Background Foot disease complications, such as foot ulcers and infection, contribute to considerable morbidity and mortality. These complications are typically precipitated by “high-risk factors”, such as peripheral neuropathy and peripheral arterial disease. High-risk factors are more prevalent in specific “at risk” populations such as diabetes, kidney disease and cardiovascular disease. To the best of the authors’ knowledge a tool capturing multiple high-risk factors and foot disease complications in multiple at risk populations has yet to be tested. This study aimed to develop and test the validity and reliability of a Queensland High Risk Foot Form (QHRFF) tool. Methods The study was conducted in two phases. Phase one developed a QHRFF using an existing diabetes foot disease tool, literature searches, stakeholder groups and expert panel. Phase two tested the QHRFF for validity and reliability. Four clinicians, representing different levels of expertise, were recruited to test validity and reliability. Three cohorts of patients were recruited; one tested criterion measure reliability (n = 32), another tested criterion validity and inter-rater reliability (n = 43), and another tested intra-rater reliability (n = 19). Validity was determined using sensitivity, specificity and positive predictive values (PPV). Reliability was determined using Kappa, weighted Kappa and intra-class correlation (ICC) statistics. Results A QHRFF tool containing 46 items across seven domains was developed. Criterion measure reliability of at least moderate categories of agreement (Kappa > 0.4; ICC > 0.75) was seen in 91% (29 of 32) tested items. Criterion validity of at least moderate categories (PPV > 0.7) was seen in 83% (60 of 72) tested items. Inter- and intra-rater reliability of at least moderate categories (Kappa > 0.4; ICC > 0.75) was seen in 88% (84 of 96) and 87% (20 of 23) tested items respectively. Conclusions The QHRFF had acceptable validity and reliability across the majority of items; particularly items identifying relevant co-morbidities, high-risk factors and foot disease complications. Recommendations have been made to improve or remove identified weaker items for future QHRFF versions. Overall, the QHRFF possesses suitable practicality, validity and reliability to assess and capture relevant foot disease items across multiple at risk populations. PMID:24468080

  16. Least reliable bits coding (LRBC) for high data rate satellite communications

    NASA Technical Reports Server (NTRS)

    Vanderaar, Mark; Budinger, James; Wagner, Paul

    1992-01-01

    LRBC, a bandwidth efficient multilevel/multistage block-coded modulation technique, is analyzed. LRBC uses simple multilevel component codes that provide increased error protection on increasingly unreliable modulated bits in order to maintain an overall high code rate that increases spectral efficiency. Soft-decision multistage decoding is used to make decisions on unprotected bits through corrections made on more protected bits. Analytical expressions and tight performance bounds are used to show that LRBC can achieve increased spectral efficiency and maintain equivalent or better power efficiency compared to that of BPSK. The relative simplicity of Galois field algebra vs the Viterbi algorithm and the availability of high-speed commercial VLSI for block codes indicates that LRBC using block codes is a desirable method for high data rate implementations.

  17. Can Touch Screen Tablets be Used to Assess Cognitive and Motor Skills in Early Years Primary School Children? A Cross-Cultural Study.

    PubMed

    Pitchford, Nicola J; Outhwaite, Laura A

    2016-01-01

    Assessment of cognitive and motor functions is fundamental for developmental and neuropsychological profiling. Assessments are usually conducted on an individual basis, with a trained examiner, using standardized paper and pencil tests, and can take up to an hour or more to complete, depending on the nature of the test. This makes traditional standardized assessments of child development largely unsuitable for use in low-income countries. Touch screen tablets afford the opportunity to assess cognitive functions in groups of participants, with untrained administrators, with precision recording of responses, thus automating the assessment process. In turn, this enables cognitive profiling to be conducted in contexts where access to qualified examiners and standardized assessments are rarely available. As such, touch screen assessments could provide a means of assessing child development in both low- and high-income countries, which would afford cross-cultural comparisons to be made with the same assessment tool. However, before touch screen tablet assessments can be used for cognitive profiling in low-to-high-income countries they need to be shown to provide reliable and valid measures of performance. We report the development of a new touch screen tablet assessment of basic cognitive and motor functions for use with early years primary school children in low- and high-income countries. Measures of spatial intelligence, visual attention, short-term memory, working memory, manual processing speed, and manual coordination are included as well as mathematical knowledge. To investigate if this new touch screen assessment tool can be used for cross-cultural comparisons we administered it to a sample of children ( N = 283) spanning standards 1-3 in a low-income country, Malawi, and a smaller sample of children ( N = 70) from first year of formal schooling from a high-income country, the UK. Split-half reliability, test-retest reliability, face validity, convergent construct validity, predictive criterion validity, and concurrent criterion validity were investigated. Results demonstrate "proof of concept" that touch screen tablet technology can provide reliable and valid psychometric measures of performance in the early years, highlighting its potential to be used in cross-cultural comparisons and research.

  18. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, E.S.; Campbell, D.V.

    1997-04-29

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer. 22 figs.

  19. Reliability analysis of a utility-scale solar power plant

    NASA Astrophysics Data System (ADS)

    Kolb, G. J.

    1992-10-01

    This paper presents the results of a reliability analysis for a solar central receiver power plant that employs a salt-in-tube receiver. Because reliability data for a number of critical plant components have only recently been collected, this is the first time a credible analysis can be performed. This type of power plant will be built by a consortium of western US utilities led by the Southern California Edison Company. The 10 MW plant is known as Solar Two and is scheduled to be on-line in 1994. It is a prototype which should lead to the construction of 100 MW commercial-scale plants by the year 2000. The availability calculation was performed with the UNIRAM computer code. The analysis predicted a forced outage rate of 5.4 percent and an overall plant availability, including scheduled outages, of 91 percent. The code also identified the most important contributors to plant unavailability. Control system failures were identified as the most important cause of forced outages. Receiver problems were rated second with turbine outages third. The overall plant availability of 91 percent exceeds the goal identified by the US utility study. This paper discuses the availability calculation and presents evidence why the 91 percent availability is a credible estimate.

  20. Rapid and reliable protein structure determination via chemical shift threading.

    PubMed

    Hafsa, Noor E; Berjanskii, Mark V; Arndt, David; Wishart, David S

    2018-01-01

    Protein structure determination using nuclear magnetic resonance (NMR) spectroscopy can be both time-consuming and labor intensive. Here we demonstrate how chemical shift threading can permit rapid, robust, and accurate protein structure determination using only chemical shift data. Threading is a relatively old bioinformatics technique that uses a combination of sequence information and predicted (or experimentally acquired) low-resolution structural data to generate high-resolution 3D protein structures. The key motivations behind using NMR chemical shifts for protein threading lie in the fact that they are easy to measure, they are available prior to 3D structure determination, and they contain vital structural information. The method we have developed uses not only sequence and chemical shift similarity but also chemical shift-derived secondary structure, shift-derived super-secondary structure, and shift-derived accessible surface area to generate a high quality protein structure regardless of the sequence similarity (or lack thereof) to a known structure already in the PDB. The method (called E-Thrifty) was found to be very fast (often < 10 min/structure) and to significantly outperform other shift-based or threading-based structure determination methods (in terms of top template model accuracy)-with an average TM-score performance of 0.68 (vs. 0.50-0.62 for other methods). Coupled with recent developments in chemical shift refinement, these results suggest that protein structure determination, using only NMR chemical shifts, is becoming increasingly practical and reliable. E-Thrifty is available as a web server at http://ethrifty.ca .

Top