Yamasaki, Fumiyuki; Kurisu, Kaoru; Aoki, Tomokazu; Yamanaka, Masami; Kajiwara, Yoshinori; Watanabe, Yosuke; Takayasu, Takeshi; Akiyama, Yuji; Sugiyama, Kazuhiko
2012-10-01
The diagnosis of pseudo-responses after bevacizumab treatment is difficult. Because diffusion-weighted imaging (DWI) is associated with cell density, it may facilitate the differentiation between true- and pseudo-responses. Furthermore, as high b-value DWI is even more sensitive to diffusion, it has been reported to be diagnostically useful in various clinical settings. Between September 2008 and May 2011, 10 patients (5 males, 5 females; age range 6-65 years) with recurrent glioma were treated with bevacizumab. All underwent pre- and post-treatment MRI including T2- or FLAIR imaging, post-gadolinium contrast T1-weighted imaging, and DWI with b-1000 and b-4000. Response rates were evaluated by MacDonald- and by response assessment in neuro-oncology working group (RANO) criteria. We also assessed the response rate by calculating the size of high intensity areas using high b-value diffusion-weighted criteria. Prognostic factors were evaluated using Kaplan-Meier survival curves (log-rank test). It was easier to identify pseudo-responses with RANO- than MacDonald criteria, however the reduction of edema by bevacizumab rendered the early diagnosis of tumor progression difficult by RANO criteria. In some patients with recurrent glioma treated with bevacizumab, high b-value diffusion-weighted criteria did, while MacDonald- and RANO criteria did not identify pseudo-responses at an early point after the start of therapy. High b-value DWI reflects cell density more accurately than regular b-value DWI. Our findings suggest that in patients with recurrent glioma, high b-value diffusion-weighted criteria are useful for the differentiation between pseudo- and true responses to treatment with bevacizumab. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Jambor, Ivan; Merisaari, Harri; Aronen, Hannu J; Järvinen, Jukka; Saunavaara, Jani; Kauko, Tommi; Borra, Ronald; Pesola, Marko
2014-05-01
To determine the optimal b-value distribution for biexponential diffusion-weighted imaging (DWI) of normal prostate using both a computer modeling approach and in vivo measurements. Optimal b-value distributions for the fit of three parameters (fast diffusion Df, slow diffusion Ds, and fraction of fast diffusion f) were determined using Monte-Carlo simulations. The optimal b-value distribution was calculated using four individual optimization methods. Eight healthy volunteers underwent four repeated 3 Tesla prostate DWI scans using both 16 equally distributed b-values and an optimized b-value distribution obtained from the simulations. The b-value distributions were compared in terms of measurement reliability and repeatability using Shrout-Fleiss analysis. Using low noise levels, the optimal b-value distribution formed three separate clusters at low (0-400 s/mm2), mid-range (650-1200 s/mm2), and high b-values (1700-2000 s/mm2). Higher noise levels resulted into less pronounced clustering of b-values. The clustered optimized b-value distribution demonstrated better measurement reliability and repeatability in Shrout-Fleiss analysis compared with 16 equally distributed b-values. The optimal b-value distribution was found to be a clustered distribution with b-values concentrated in the low, mid, and high ranges and was shown to improve the estimation quality of biexponential DWI parameters of in vivo experiments. Copyright © 2013 Wiley Periodicals, Inc.
Mardor, Yael; Roth, Yiftach; Ocherashvilli, Aharon; Spiegelmann, Roberto; Tichler, Thomas; Daniels, Dianne; Maier, Stephan E; Nissim, Ouzi; Ram, Zvi; Baram, Jacob; Orenstein, Arie; Pfeffer, Raphael
2004-01-01
Abstract Diffusion-weighted magnetic resonance imaging (DWMRI) is sensitive to tissues' biophysical characteristics, including apparent diffusion coefficients (ADCs) and volume fractions of water in different populations. In this work, we evaluate the clinical efficacy of DWMRI and high diffusion-weighted magnetic resonance imaging (HDWMRI), acquired up to b = 4000 sec/mm2 to amplify sensitivity to water diffusion properties, in pretreatment prediction of brain tumors' response to radiotherapy. Twelve patients with 20 brain lesions were studied. Six ring-enhancing lesions were excluded due to their distinct diffusion characteristics. Conventional and DWMRI were acquired on a 0.5-T MRI. Response to therapy was determined from relative changes in tumor volumes calculated from contrast-enhanced T1-weighted MRI, acquired before and a mean of 46 days after beginning therapy. ADCs and a diffusion index, RD, reflecting tissue viability based on water diffusion were calculated from DWMRIs. Pretreatment values of ADC and RD were found to correlate significantly with later tumor response/nonresponse (r = 0.76, P < .002 and r = 0.77, P < .001). This correlation implies that tumors with low pretreatment diffusion values, indicating high viability, will respond better to radiotherapy than tumors with high diffusion values, indicating necrosis. These results demonstrate the feasibility of using DWMRI for pretreatment prediction of response to therapy in patients with brain tumors undergoing radiotherapy. PMID:15140402
Mardor, Yael; Roth, Yiftach; Ochershvilli, Aharon; Spiegelmann, Roberto; Tichler, Thomas; Daniels, Dianne; Maier, Stephan E; Nissim, Ouzi; Ram, Zvi; Baram, Jacob; Orenstein, Arie; Pfeffer, Raphael
2004-01-01
Diffusion-weighted magnetic resonance imaging (DWMRI) is sensitive to tissues' biophysical characteristics, including apparent diffusion coefficients (ADCs) and volume fractions of water in different populations. In this work, we evaluate the clinical efficacy of DWMRI and high diffusion-weighted magnetic resonance imaging (HDWMRI), acquired up to b = 4000 sec/mm(2) to amplify sensitivity to water diffusion properties, in pretreatment prediction of brain tumors' response to radiotherapy. Twelve patients with 20 brain lesions were studied. Six ring-enhancing lesions were excluded due to their distinct diffusion characteristics. Conventional and DWMRI were acquired on a 0.5-T MRI. Response to therapy was determined from relative changes in tumor volumes calculated from contrast-enhanced T1-weighted MRI, acquired before and a mean of 46 days after beginning therapy. ADCs and a diffusion index, R(D), reflecting tissue viability based on water diffusion were calculated from DWMRIs. Pretreatment values of ADC and R(D) were found to correlate significantly with later tumor response/nonresponse (r = 0.76, P <.002 and r = 0.77, P <.001). This correlation implies that tumors with low pretreatment diffusion values, indicating high viability, will respond better to radiotherapy than tumors with high diffusion values, indicating necrosis. These results demonstrate the feasibility of using DWMRI for pretreatment prediction of response to therapy in patients with brain tumors undergoing radiotherapy.
Diffusion-weighted imaging of the breast: principles and clinical applications.
Woodhams, Reiko; Ramadan, Saadallah; Stanwell, Peter; Sakamoto, Satoko; Hata, Hirofumi; Ozaki, Masanori; Kan, Shinichi; Inoue, Yusuke
2011-01-01
Diffusion-weighted imaging provides a novel contrast mechanism in magnetic resonance (MR) imaging and has a high sensitivity in the detection of changes in the local biologic environment. A significant advantage of diffusion-weighted MR imaging over conventional contrast material-enhanced MR imaging is its high sensitivity to change in the microscopic cellular environment without the need for intravenous contrast material injection. Approaches to the assessment of diffusion-weighted breast imaging findings include assessment of these data alone and interpretation of the data in conjunction with T2-weighted imaging findings. In addition, the analysis of apparent diffusion coefficient (ADC) value can be undertaken either in isolation or in combination with diffusion-weighted and T2-weighted imaging. Most previous studies have evaluated ADC value alone; however, overlap in the ADC values of malignant and benign disease has been observed. This overlap may be partly due to selection of b value, which can influence the concomitant effect of perfusion and emphasize the contribution of multicomponent model influences. The simultaneous assessment of diffusion-weighted and T2-weighted imaging data and ADC value has the potential to improve specificity. In addition, the use of diffusion-weighted imaging in a standard breast MR imaging protocol may heighten sensitivity and thereby improve diagnostic accuracy. Standardization of diffusion-weighted imaging parameters is needed to allow comparison of multicenter studies and assessment of the clinical utility of diffusion-weighted imaging and ADC values in breast evaluation.
O'Brien, Kieran; Daducci, Alessandro; Kickler, Nils; Lazeyras, Francois; Gruetter, Rolf; Feiweier, Thorsten; Krueger, Gunnar
2013-08-01
Clinical use of the Stejskal-Tanner diffusion weighted images is hampered by the geometric distortions that result from the large residual 3-D eddy current field induced. In this work, we aimed to predict, using linear response theory, the residual 3-D eddy current field required for geometric distortion correction based on phantom eddy current field measurements. The predicted 3-D eddy current field induced by the diffusion-weighting gradients was able to reduce the root mean square error of the residual eddy current field to ~1 Hz. The model's performance was tested on diffusion weighted images of four normal volunteers, following distortion correction, the quality of the Stejskal-Tanner diffusion-weighted images was found to have comparable quality to image registration based corrections (FSL) at low b-values. Unlike registration techniques the correction was not hindered by low SNR at high b-values, and results in improved image quality relative to FSL. Characterization of the 3-D eddy current field with linear response theory enables the prediction of the 3-D eddy current field required to correct eddy current induced geometric distortions for a wide range of clinical and high b-value protocols.
Han, Haiwei; Han, Chengkun; Wu, Xiurong; Zhong, Shan; Zhuang, Xiongjie; Tan, Guowei; Wu, Hua
2017-05-01
The purpose of this study was to determine the difference in discrimination between high- and low-grade supratentorial nonenhancing gliomas (HGGs and LGGs, respectively) when using apparent diffusion coefficient (ADC) values with high or standard b-value. Thirty-nine patients underwent conventional magnetic resonance imaging and diffusion-weighted imaging (DWI) with standard and high b-values (b = 1000 and 3000 s/mm 2 , respectively). Minimum, maximum, and mean ADC values (ADC MIN , ADC MAX , and ADC MEAN , respectively) were measured from ADC maps with both b-values. Receiver operating curve analysis was used to determine the cutoff ADC values for distinguishing between nonenhancing HGGs and LGGs. ADC MIN , ADC MAX , and ADC MEAN values for the nonenhancing HGGs were lower than those for LGGs. These differences were much larger when a high b-value was used (all P < 0.0001) than when a standard b-value was used (P = 0.0001, <0.0001, and <0.0001, respectively). Discriminant analysis indicated that the greatest likelihood for discriminating HGGs and LGGs when ADC MEAN was obtained with a high b-value, with cutoff value of 0.814 × 10 -3 mm 2 /s. ADC values obtained with a high b-value can be useful for grading and surgical management of nonenhancing HGGs and LGGs. The lowest degree of overlap was obtained when ADC MEAN was determined with a b-value of 3000 s/mm 2 .
Roth, Yiftach; Tichler, Thomas; Kostenich, Genady; Ruiz-Cabello, Jesus; Maier, Stephan E; Cohen, Jack S; Orenstein, Arie; Mardor, Yael
2004-09-01
To evaluate the use of diffusion-weighted magnetic resonance (MR) imaging with standard and high b values for pretreatment prediction and early detection of tumor response to various antineoplastic therapies in an animal model. Mice bearing C26 colon carcinoma tumors were treated with doxorubicin (n = 25) and with aminolevulinic acid-based photodynamic therapy (n = 23). Fourteen mice served as controls. Conventional T2-weighted fast spin-echo and diffusion-weighted MR images were acquired once before therapy and at 6, 24, and 48 hours after treatment. Pretreatment and early (1-2 days) posttreatment water diffusion parameters were calculated and compared with later changes in tumor volumes measured on conventional MR images by using the Pearson correlation test. In chemotherapy-treated tumors, a significant correlation (P <.002, r = 0.6) was observed between diffusion parameters that reflected tumor viability, measured prior to treatment, and changes in tumor volumes after therapy. This correlation implies that tumors with high pretreatment viability will respond better to chemotherapy than more necrotic tumors. In tumors treated with photodynamic therapy, no such correlation was found. Changes observed in water diffusion 1-2 days after treatment significantly correlated with later tumor growth rate for both therapies (P <.002, r = 0.54 for photodynamic therapy; P <.0003, r = 0.61 for chemotherapy). High-b-value diffusion-weighted MR imaging has potential use for the early detection of response to therapy and for predicting treatment outcome prior to initiation of chemotherapy. Copyright RSNA, 2004
NASA Astrophysics Data System (ADS)
Schilling, Kurt G.; Nath, Vishwesh; Blaber, Justin; Harrigan, Robert L.; Ding, Zhaohua; Anderson, Adam W.; Landman, Bennett A.
2017-02-01
High-angular-resolution diffusion-weighted imaging (HARDI) MRI acquisitions have become common for use with higher order models of diffusion. Despite successes in resolving complex fiber configurations and probing microstructural properties of brain tissue, there is no common consensus on the optimal b-value and number of diffusion directions to use for these HARDI methods. While this question has been addressed by analysis of the diffusion-weighted signal directly, it is unclear how this translates to the information and metrics derived from the HARDI models themselves. Using a high angular resolution data set acquired at a range of b-values, and repeated 11 times on a single subject, we study how the b-value and number of diffusion directions impacts the reproducibility and precision of metrics derived from Q-ball imaging, a popular HARDI technique. We find that Q-ball metrics associated with tissue microstructure and white matter fiber orientation are sensitive to both the number of diffusion directions and the spherical harmonic representation of the Q-ball, and often are biased when under sampled. These results can advise researchers on appropriate acquisition and processing schemes, particularly when it comes to optimizing the number of diffusion directions needed for metrics derived from Q-ball imaging.
Jiang, Jing; Liu, Wanhua; Ye, Yuanyuan; Wang, Rui; Li, Fengfang; Peng, Chengyu
2014-06-17
To investigate the diagnostic efficiency of decline rate of signal intensity and apparent diffusion coefficient with different b values for differentiating benign and malignant breast lesions on diffusion-weighted 3.0 T magnetic resonance imaging. A total of 152 patients with 162 confirmed histopathologically breast lesions (85 malignant and 77 benign) underwent 3.0 T diffusion-weighted magnetic resonance imaging. Four b values (0, 400, 800 and 1 000 s/mm²) were used. The signal intensity and ADC values of breast lesions were measured respectively. The signal intensity decline rate (SIDR) and apparent diffusion coefficient decline rate (ADCDR) were calculated respectively. SIDR = (signal intensity of lesions with low b value-signal intensity of lesions with high b value)/signal intensity of lesions with low b value, ADCDR = (ADC value of lesions with low b value-ADC value of lesions with high b value) /ADC value of lesions with low b value. The independent sample t-test was employed for statistical analyses and the receiver operating characteristic (ROC) curve for evaluating the diagnosis efficiency of SIDR and ADCDR values. Significant differences were observed in SIDR between benign and malignant breast lesions with b values of 0-400, 400-800 and 800-1 000 s/mm². The sensitivities of SIDR for differentiating benign and malignant breast lesions were 61.2%, 68.2% and 67.1%, the specificities 74.0%, 85.7% and 67.5%, the diagnosis accordance rates 67.3%, 76.5% and 67.3%, the positive predictive values 72.2%, 84.1% and 69.5% and the negative predictive values 63.3%, 71.0% and 65.0% respectively. Significant differences were observed in ADCDR between benign and malignant breast lesions with b values of 400-800 s/mm² and 800-1 000 s/mm². The sensitivities of SDR for differentiating benign and malignant breast lesions were 80.0% and 65.9%, the specificities 72.7% and 65.0%, the diagnostic accordance rates 76.5% and 65.4%, the positive predictive values 76.4% and 67.5% and the negative predictive values 76.7% and 63.3% respectively. The decline rate of signal intensity and apparent diffusion coefficient with different b values may be used for differentiating benign and malignant breast lesions. And the diagnostic efficiency with b values of 400-800 s/mm² is optimal.
Ikink, Marlijne E; Voogt, Marianne J; van den Bosch, Maurice A A J; Nijenhuis, Robbert J; Keserci, Bilgin; Kim, Young-sun; Vincken, Koen L; Bartels, Lambertus W
2014-09-01
To assess the value of diffusion-weighted magnetic resonance imaging (DWI) and apparent diffusion coefficient (ADC) mapping using different b-value combinations for treatment evaluation after magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) of uterine fibroids. Fifty-six patients with 67 uterine fibroids were treated with volumetric MR-HIFU. Pre-treatment and post-treatment images were obtained using contrast-enhanced T1-weighted MRI (CE-T1WI) and DWI using b = 0, 200, 400, 600, 800 s/mm(2). ADC maps were generated using subsets of b-values to investigate the effects of tissue ablation on water diffusion and perfusion in fibroids treated with MR-HIFU. Four combinations of b-values were used: (1) all b-values; (2) b = 0, 200 s/mm(2); (3) b = 400, 600, 800 s/mm(2); and (4) b = 0, 800 s/mm(2). Using the lowest b-values (0 and 200 s/mm(2)), the mean ADC value in the ablated tissue reduced significantly (p < 0.001) compared with baseline. Calculating the ADC value with the highest b-values (400, 600, 800 s/mm(2)), the ADC increased significantly (p < 0.001) post-treatment. ADC maps calculated with the lowest b-values resulted in the best visual agreement of non-perfused fibroid tissue detected on CE images. Other b-value combinations and normal myometrium showed no difference in ADC after MR-HIFU treatment. A decrease in contrast agent uptake within the ablated region on CE-T1WI was correlated to a significantly decreased ADC when b = 0 and 200 s/mm(2) were used. DWI could be useful for treatment evaluation after MR-HIFU of uterine fibroids. The ADC in fibroid tissue is influenced by the choice of b- values. Low b-values seem the best choice to emphasise perfusion effects after MR-HIFU.
Karadeli, Elif; Erbay, Gurcan; Parlakgumus, Alper; Koc, Zafer
2018-02-01
To determine the feasibility of diffusion-weighted imaging in evaluation of pancreatic lesions and in differentiation of benign from malignant lesions. Descriptive study. Baskent University Adana Teaching and Research Center, Adana, Turkey, between September 2013 and May 2015. Forty-three lesions [pancreas adenocarcinoma (n=25)], pancreatitis (n=10), benign lesion (n=8)] were utilized with diffusion-weighted magnetic resonance imaging with multiple b-values. Different ADC maps of diffusion weighted images by using b-values were acquired. The median ADC at all b values for malignant lesions was significantly different from that for benign lesions (p<0.001). When ADCs at all b values were compared between benign lesions/normal parenchyma and malignant lesions/normal parenchyma, there was a significant statistical difference in all b values between benign and malignant lesions except at b 50 and b 200 (p<0.05). The lesion/normal parenchyma ADC ratio for b 600 value (AUC=0.804) was more effective than the lesion ADC for b 600 value (AUC=0.766) in differentiation of benign and malignant lesions. The specificity and sensitivity of the lesion/normal parenchyma ADC ratio were higher than those of ADC values of lesions. When the ADC was compared between benign lesions and pancreatitis, a significant difference was found at all b values (p<0.001). There was not a statistically significant difference between the ADC for pancreatitis and that for malignant lesions at any b value combinations (p>0.05). Diffusion-weighted magnetic resonance images can be helpful in differentiation of pancreatic carcinoma and benign lesions. Lesion ADC / normal parenchyma ADC ratios are more important than lesion ADC values in assessment of pancreatic lesions.
Kitajima, Kazuhiro; Takahashi, Satoru; Ueno, Yoshiko; Yoshikawa, Takeshi; Ohno, Yoshiharu; Obara, Makoto; Miyake, Hideaki; Fujisawa, Masato; Sugimura, Kazuro
2012-07-01
To determine whether the apparent diffusion coefficient (ADC) obtained using b = 2000 s/mm(2) upon 3 Tesla (T) diffusion-weighted MRI is superior to b = 1000 s/mm(2) for discriminating malignant from normal prostate tissue and predicting the aggressiveness of prostate cancer, using histopathological findings of radical prostatectomy as a reference. Eighty prostate cancer patients underwent preoperative 3T MRI including diffusion weighted imaging with b-values of 0, 1000, and 2000 s/mm(2) . ADCs were measured for malignant lesions and normal sites on three sets of ADC maps calculated with monoexponential fitting between b = 0 and 1000, 0 and 2000, and 1000 and 2000, respectively. The relationship between the ADC and Gleason score was evaluated. The areas under the ROC curves for b = 0,1000, b = 0,2000, and b = 1000,2000 were 0.896, 0.937, and 0.857, respectively, in the peripheral zone (PZ) and 0.877, 0.889, and 0.731, respectively, in the transition zone (TZ). The difference between b = 0,1000 and b = 0,2000 was significant in PZ (P = 0.033), but not in TZ (P = 0.84). Weak but significant negative correlations were identified between ADCs and Gleason score in both PZ and TZ cancer at b = 0,1000 and b = 0,2000 (r = -0.323 to -0.341). For 3T MRI, ADCs using b = 0,2000 are more accurate than b = 0,1000 for diagnosing PZ cancer, and as accurate for TZ cancer. Copyright © 2012 Wiley Periodicals, Inc.
Zeng, Qiang; Shi, Feina; Zhang, Jianmin; Ling, Chenhan; Dong, Fei; Jiang, Biao
2018-01-01
Purpose: To present a new modified tri-exponential model for diffusion-weighted imaging (DWI) to detect the strictly diffusion-limited compartment, and to compare it with the conventional bi- and tri-exponential models. Methods: Multi-b-value diffusion-weighted imaging (DWI) with 17 b-values up to 8,000 s/mm2 were performed on six volunteers. The corrected Akaike information criterions (AICc) and squared predicted errors (SPE) were calculated to compare these three models. Results: The mean f0 values were ranging 11.9–18.7% in white matter ROIs and 1.2–2.7% in gray matter ROIs. In all white matter ROIs: the AICcs of the modified tri-exponential model were the lowest (p < 0.05 for five ROIs), indicating the new model has the best fit among these models; the SPEs of the bi-exponential model were the highest (p < 0.05), suggesting the bi-exponential model is unable to predict the signal intensity at ultra-high b-value. The mean ADCvery−slow values were extremely low in white matter (1–7 × 10−6 mm2/s), but not in gray matter (251–445 × 10−6 mm2/s), indicating that the conventional tri-exponential model fails to represent a special compartment. Conclusions: The strictly diffusion-limited compartment may be an important component in white matter. The new model fits better than the other two models, and may provide additional information. PMID:29535599
Verma, Sadhna; Sarkar, Saradwata; Young, Jason; Venkataraman, Rajesh; Yang, Xu; Bhavsar, Anil; Patil, Nilesh; Donovan, James; Gaitonde, Krishnanath
2016-05-01
The purpose of this study was to compare high b-value (b = 2000 s/mm(2)) acquired diffusion-weighted imaging (aDWI) with computed DWI (cDWI) obtained using four diffusion models-mono-exponential (ME), intra-voxel incoherent motion (IVIM), stretched exponential (SE), and diffusional kurtosis (DK)-with respect to lesion visibility, conspicuity, contrast, and ability to predict significant prostate cancer (PCa). Ninety four patients underwent 3 T MRI including acquisition of b = 2000 s/mm(2) aDWI and low b-value DWI. High b = 2000 s/mm(2) cDWI was obtained using ME, IVIM, SE, and DK models. All images were scored on quality independently by three radiologists. Lesions were identified on all images and graded for lesion conspicuity. For a subset of lesions for which pathological truth was established, lesion-to-background contrast ratios (LBCRs) were computed and binomial generalized linear mixed model analysis was conducted to compare clinically significant PCa predictive capabilities of all DWI. For all readers and all models, cDWI demonstrated higher ratings for image quality and lesion conspicuity than aDWI except DK (p < 0.001). The LBCRs of ME, IVIM, and SE were significantly higher than LBCR of aDWI (p < 0.001). Receiver Operating Characteristic curves obtained from binomial generalized linear mixed model analysis demonstrated higher Area Under the Curves for ME, SE, IVIM, and aDWI compared to DK or PSAD alone in predicting significant PCa. High b-value cDWI using ME, IVIM, and SE diffusion models provide better image quality, lesion conspicuity, and increased LBCR than high b-value aDWI. Using cDWI can potentially provide comparable sensitivity and specificity for detecting significant PCa as high b-value aDWI without increased scan times and image degradation artifacts.
Sapkota, Nabraj; Yoon, Sook; Thapa, Bijaya; Lee, YouJung; Bisson, Erica F; Bowman, Beth M; Miller, Scott C; Shah, Lubdha M; Rose, John W; Jeong, Eun-Kee
2016-11-01
Signal measured from white matter in diffusion-weighted imaging is difficult to interpret because of the heterogeneous structure of white matter. Characterization of the white matter will be straightforward if the signal contributed from the hindered space is suppressed and purely restricted signal is analyzed. In this study, a Monte Carlo simulation (MCS) of water diffusion in white matter was performed to understand the behavior of the diffusion-weighted signal in white matter. The signal originating from the hindered space of an excised pig cervical spinal cord white matter was suppressed using the ultrahigh-b radial diffusion-weighted imaging. A light microscopy image of a section of white matter was obtained from the excised pig cervical spinal cord for the MCS. The radial diffusion-weighted signals originating from each of the intra-axonal, extra-axonal, and total spaces were studied using the MCS. The MCS predicted that the radial diffusion-weighted signal remains almost constant in the intra-axonal space and decreases gradually to about 2% of its initial value in the extra-axonal space when the b-value is increased to 30,000s/mm 2 . The MCS also revealed that the diffusion-weighted signal for a b-value greater than 20,000s/mm 2 is mostly from the intra-axonal space. The decaying behavior of the signal-b curve obtained from ultrahigh-b diffusion-weighted imaging (b max ∼30,000s/mm 2 ) of the excised pig cord was very similar to the decaying behavior of the total signal-b curve synthesized in the MCS. A mono-exponential plus constant fitting of the signal-b curve obtained from a white matter pixel estimated the values of constant fraction and apparent diffusion coefficient of decaying fraction as 0.32±0.05 and (0.16±0.01)×10 -3 mm 2 /s, respectively, which agreed well with the results of the MCS. The signal measured in the ultrahigh-b region (b>20,000s/mm 2 ) is mostly from the restricted (intra-axonal) space. Integrity and intactness of the axons can be evaluated by assessing the remaining signal in the ultrahigh-b region. Published by Elsevier Inc.
Lukas, Vanessa A; Fishbein, Kenneth W; Reiter, David A; Lin, Ping-Chang; Schneider, Erika; Spencer, Richard G
2015-07-01
To evaluate the sensitivity and specificity of classification of pathomimetically degraded bovine nasal cartilage at 3 Tesla and 37°C using univariate MRI measurements of both pure parameter values and intensities of parameter-weighted images. Pre- and posttrypsin degradation values of T1 , T2 , T2 *, magnetization transfer ratio (MTR), and apparent diffusion coefficient (ADC), and corresponding weighted images, were analyzed. Classification based on the Euclidean distance was performed and the quality of classification was assessed through sensitivity, specificity and accuracy (ACC). The classifiers with the highest accuracy values were ADC (ACC = 0.82 ± 0.06), MTR (ACC = 0.78 ± 0.06), T1 (ACC = 0.99 ± 0.01), T2 derived from a three-dimensional (3D) spin-echo sequence (ACC = 0.74 ± 0.05), and T2 derived from a 2D spin-echo sequence (ACC = 0.77 ± 0.06), along with two of the diffusion-weighted signal intensities (b = 333 s/mm(2) : ACC = 0.80 ± 0.05; b = 666 s/mm(2) : ACC = 0.85 ± 0.04). In particular, T1 values differed substantially between the groups, resulting in atypically high classification accuracy. The second-best classifier, diffusion weighting with b = 666 s/mm(2) , as well as all other parameters evaluated, exhibited substantial overlap between pre- and postdegradation groups, resulting in decreased accuracies. Classification according to T1 values showed excellent test characteristics (ACC = 0.99), with several other parameters also showing reasonable performance (ACC > 0.70). Of these, diffusion weighting is particularly promising as a potentially practical clinical modality. As in previous work, we again find that highly statistically significant group mean differences do not necessarily translate into accurate clinical classification rules. © 2014 Wiley Periodicals, Inc.
Zhang, Qinwei; Coolen, Bram F; Versluis, Maarten J; Strijkers, Gustav J; Nederveen, Aart J
2017-07-01
In this study, we present a new three-dimensional (3D), diffusion-prepared turbo spin echo sequence based on a stimulated-echo read-out (DPsti-TSE) enabling high-resolution and undistorted diffusion-weighted imaging (DWI). A dephasing gradient in the diffusion preparation module and rephasing gradients in the turbo spin echo module create stimulated echoes, which prevent signal loss caused by eddy currents. Near to perfect agreement of apparent diffusion coefficient (ADC) values between DPsti-TSE and diffusion-weighted echo planar imaging (DW-EPI) was demonstrated in both phantom transient signal experiments and phantom imaging experiments. High-resolution and undistorted DPsti-TSE was demonstrated in vivo in prostate and carotid vessel wall. 3D whole-prostate DWI was achieved with four b values in only 6 min. Undistorted ADC maps of the prostate peripheral zone were obtained at low and high imaging resolutions with no change in mean ADC values [(1.60 ± 0.10) × 10 -3 versus (1.60 ± 0.02) × 10 -3 mm 2 /s]. High-resolution 3D DWI of the carotid vessel wall was achieved in 12 min, with consistent ADC values [(1.40 ± 0.23) × 10 -3 mm 2 /s] across different subjects, as well as slice locations through the imaging volume. This study shows that DPsti-TSE can serve as a robust 3D diffusion-weighted sequence and is an attractive alternative to the traditional two-dimensional DW-EPI approaches. Copyright © 2017 John Wiley & Sons, Ltd.
Evaluation of diffusion models in breast cancer.
Panek, Rafal; Borri, Marco; Orton, Matthew; O'Flynn, Elizabeth; Morgan, Veronica; Giles, Sharon L; deSouza, Nandita; Leach, Martin O; Schmidt, Maria A
2015-08-01
The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing gradient ranges were explored in phantom studies. The effect of eddy currents and accuracy of b-value determination using a multiple b-value diffusion-weighted MR imaging sequence were investigated in test objects. Diffusion model selection and noise were then investigated in volunteers (n = 5) and breast tumor patients (n = 21) using the Bayesian information criterion. 54.3% of lesion voxels were best fitted by a monoexponential, 26.2% by a stretched-exponential, and 19.5% by a biexponential intravoxel incoherent motion (IVIM) model. High correlation (0.92) was observed between diffusion coefficients calculated using mono- and stretched-exponential models and moderate (0.59) between monoexponential and IVIM (medians: 0.96/0.84/0.72 × 10(-3) mm(2)/s, respectively). Distortion due to eddy currents depended on the direction of the diffusion gradient and displacement varied between 1 and 6 mm for high b-value images. Shift in the apparent diffusion coefficient due to intrinsic field gradients was compensated for by averaging diffusion data obtained from opposite directions. Pseudodiffusion and intravoxel heterogeneity effects were not observed in approximately half of breast cancer and normal tissue voxels. This result indicates that stretched and IVIM models should be utilized in regional analysis rather than global tumor assessment. Cross terms between diffusion-sensitization gradients and other imaging or susceptibility-related gradients are relevant in clinical protocols, supporting the use of geometric averaging of diffusion-weighted images acquired with diffusion-sensitization gradients in opposite directions.
Sepehrband, Farshid; O'Brien, Kieran; Barth, Markus
2017-12-01
Several diffusion-weighted MRI techniques have been developed and validated during the past 2 decades. While offering various neuroanatomical inferences, these techniques differ in their proposed optimal acquisition design, preventing clinicians and researchers benefiting from all potential inference methods, particularly when limited time is available. This study reports an optimal design that enables for a time-efficient diffusion-weighted MRI acquisition scheme at 7 Tesla. The primary audience of this article is the typical end user, interested in diffusion-weighted microstructural imaging at 7 Tesla. We tested b-values in the range of 700 to 3000 s/mm 2 with different number of angular diffusion-encoding samples, against a data-driven "gold standard." The suggested design is a protocol with b-values of 1000 and 2500 s/mm 2 , with 25 and 50 samples, uniformly distributed over two shells. We also report a range of protocols in which the results of fitting microstructural models to the diffusion-weighted data had high correlation with the gold standard. We estimated minimum acquisition requirements that enable diffusion tensor imaging, higher angular resolution diffusion-weighted imaging, neurite orientation dispersion, and density imaging and white matter tract integrity across whole brain with isotropic resolution of 1.8 mm in less than 11 min. Magn Reson Med 78:2170-2184, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Nilsson, Markus; Szczepankiewicz, Filip; van Westen, Danielle; Hansson, Oskar
2015-01-01
Conventional motion and eddy-current correction, where each diffusion-weighted volume is registered to a non diffusion-weighted reference, suffers from poor accuracy for high b-value data. An alternative approach is to extrapolate reference volumes from low b-value data. We aim to compare the performance of conventional and extrapolation-based correction of diffusional kurtosis imaging (DKI) data, and to demonstrate the impact of the correction approach on group comparison studies. DKI was performed in patients with Parkinson's disease dementia (PDD), and healthy age-matched controls, using b-values of up to 2750 s/mm2. The accuracy of conventional and extrapolation-based correction methods was investigated. Parameters from DTI and DKI were compared between patients and controls in the cingulum and the anterior thalamic projection tract. Conventional correction resulted in systematic registration errors for high b-value data. The extrapolation-based methods did not exhibit such errors, yielding more accurate tractography and up to 50% lower standard deviation in DKI metrics. Statistically significant differences were found between patients and controls when using the extrapolation-based motion correction that were not detected when using the conventional method. We recommend that conventional motion and eddy-current correction should be abandoned for high b-value data in favour of more accurate methods using extrapolation-based references.
Karan, Belgin; Erbay, Gurcan; Koc, Zafer; Pourbagher, Aysin; Yildirim, Sedat; Agildere, Ahmet Muhtesem
2016-11-01
The study sought to evaluate the potential of diffusion-weighted magnetic resonance imaging to detect changes in liver diffusion in benign and malignant distal bile duct obstruction and to investigate the effect of the choice of b-values on apparent diffusion coefficient (ADC). Diffusion-weighted imaging was acquired with b-values of 200, 600, 800, and 1000 s/mm 2 . ADC values were obtained in 4 segments of the liver. The mean ADC values of 16 patients with malignant distal bile duct obstruction, 14 patients with benign distal bile duct obstruction, and a control group of 16 healthy patients were compared. Mean ADC values for 4 liver segments were lower in the malignant obstruction group than in the benign obstruction and control groups using b = 200 s/mm 2 (P < .05). Mean ADC values of the left lobe medial and lateral segments were lower in the malignant obstruction group than in the benign obstructive and control groups using b = 600 s/mm 2 (P < .05). Mean ADC values of the right lobe posterior segment were lower in the malignant and benign obstruction groups than in the control group using b = 1000 s/mm 2 (P < .05). Using b = 800 s/mm 2 , ADC values of all 4 liver segments in each group were not significantly different (P > .05). There were no correlations between the ADC values of liver segments and liver function tests. Measurement of ADC shows good potential for detecting changes in liver diffusion in patients with distal bile duct obstruction. Calculated ADC values were affected by the choice of b-values. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Kanmaz, Lutfi; Karavas, Erdal
2018-05-29
The purpose of this study was to evaluate the value of diffusion-weighted MRI (DW-MRI) in differentiating benign and malignant head and neck masses by comparing their apparent diffusion coefficient (ADC) values. The study included 32 patients with a neck mass >1 cm in diameter who were examined with echo planar DW-MRI. Two different diffusion gradients (b values of b = 0 and b = 1000 s/mm²) were applied. DWI and ADC maps of 32 neck masses in 32 patients were obtained. Mean ADC values of benign and malignant neck lesions were measured and compared statistically. A total of 15 (46.9%) malignant masses and 17 (53.1%) benign masses were determined. Of all the neck masses, the ADC value of cystic masses was the highest and that of lymphomas was the lowest. The mean ADC values of benign and malignant neck masses were 1.57 × 10 -3 mm²/s and 0.90 × 10 -3 mm²/s, respectively. The difference between mean ADC values of benign and malignant neck masses was significant ( p < 0.01). Diffusion-weighted MRI with ADC measurements can be useful in the differential diagnosis of neck masses.
Sui, Yi; Wang, He; Liu, Guanzhong; Damen, Frederick W.; Wanamaker, Christian; Li, Yuhua
2015-01-01
Purpose To demonstrate that a new set of parameters (D, β, and μ) from a fractional order calculus (FROC) diffusion model can be used to improve the accuracy of MR imaging for differentiating among low- and high-grade pediatric brain tumors. Materials and Methods The institutional review board of the performing hospital approved this study, and written informed consent was obtained from the legal guardians of pediatric patients. Multi-b-value diffusion-weighted magnetic resonance (MR) imaging was performed in 67 pediatric patients with brain tumors. Diffusion coefficient D, fractional order parameter β (which correlates with tissue heterogeneity), and a microstructural quantity μ were calculated by fitting the multi-b-value diffusion-weighted images to an FROC model. D, β, and μ values were measured in solid tumor regions, as well as in normal-appearing gray matter as a control. These values were compared between the low- and high-grade tumor groups by using the Mann-Whitney U test. The performance of FROC parameters for differentiating among patient groups was evaluated with receiver operating characteristic (ROC) analysis. Results None of the FROC parameters exhibited significant differences in normal-appearing gray matter (P ≥ .24), but all showed a significant difference (P < .002) between low- (D, 1.53 μm2/msec ± 0.47; β, 0.87 ± 0.06; μ, 8.67 μm ± 0.95) and high-grade (D, 0.86 μm2/msec ± 0.23; β, 0.73 ± 0.06; μ, 7.8 μm ± 0.70) brain tumor groups. The combination of D and β produced the largest area under the ROC curve (0.962) in the ROC analysis compared with individual parameters (β, 0.943; D,0.910; and μ, 0.763), indicating an improved performance for tumor differentiation. Conclusion The FROC parameters can be used to differentiate between low- and high-grade pediatric brain tumor groups. The combination of FROC parameters or individual parameters may serve as in vivo, noninvasive, and quantitative imaging markers for classifying pediatric brain tumors. © RSNA, 2015 PMID:26035586
Cihangiroglu, M M; Ozturk-Isik, E; Firat, Z; Kilickesmez, O; Ulug, A M; Ture, U
2017-03-01
The goal of this study was to compare diffusion-weighted magnetic resonance imaging (DW-MRI) using high b-value (b=3000s/mm 2 ) to DW-MRI using standard b-value (b=1000s/mm 2 ) in the preoperative grading of supratentorial gliomas. Fifty-three patients with glioma had brain DW-MRI at 3T using two different b-values (b=1000s/mm 2 and b=3000s/mm 2 ). There were 35 men and 18 women with a mean age of 40.5±17.1 years (range: 18-79 years). Mean, minimum, maximum, and range of apparent diffusion coefficient (ADC) values for solid tumor ROIs (ADC mean , ADC min , ADC max , and ADC diff ), and the normalized ADC (ADC ratio ) were calculated. A Kruskal-Wallis statistic with Bonferroni correction for multiple comparisons was applied to detect significant ADC parameter differences between tumor grades by including or excluding 19 patients with an oligodendroglioma. Receiver operating characteristic curve analysis was conducted to define appropriate cutoff values for grading gliomas. No differences in ADC derived parameters were found between grade II and grade III gliomas. Mean ADC values using standard b-value were 1.17±0.27×10 -3 mm 2 /s [range: 0.63-1.61], 1.05±0.22×10 -3 mm 2 /s [range: 0.73-1.33], and 0.86±0.23×10 -3 mm 2 /s [range: 0.52-1.46] for grades II, III and IV gliomas, respectively. Using high b-value, mean ADC values were 0.89±0.24×10 -3 mm 2 /s [range: 0.42-1.25], 0.82±0.20×10 -3 mm 2 /s [range: 0.56-1.10], and 0.59±0.17×10 -3 mm 2 /s [range: 0.40-1.01] for grades II, III and IV gliomas, respectively. ADC mean , ADC ratio , ADC max , and ADC min were different between grade II and grade IV gliomas at both standard and high b-values. Differences in ADC mean , ADC max , and ADC diff were found between grade III and grade IV only using high b-value. ADC parameters derived from DW-MRI using a high b-value allows a better differential diagnosis of gliomas, especially for differentiating grades III and IV, than those derived from DW-MRI using a standard b-value. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Saito, Kazuhiro; Yoshimura, Nobutaka; Shirota, Natsuhiko; Saguchi, Toru; Sugimoto, Katsutoshi; Tokuuye, Koichi
2016-10-01
The aim of this study to evaluate the effectiveness of enhanced diffusion-weighted imaging (DWI) for distinguishing liver haemangiomas from metastatic tumours (mets). This study included 23 patients with 27 haemangiomas and 26 patients with 46 mets. Breath-holding diffusion-weighted imaging (DWI) (b-values of 0, 50, 100, 150, 200, 400 and 800 s/mm 2 ) were obtained before and 20 min after injection of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA). Lesion contrast-to-noise ratios (CNRs) were calculated. The data were processed using the bi-exponential model of intravoxel incoherent motion (IVIM). Receiver operating characteristic analysis was performed to compare the diagnostic performance when distinguishing haemangioma from mets. The CNRs of haemangioma and mets at post-contrast enhancement increased. All IVIM parameters for liver haemangioma and mets showed no significant differences between pre- and post-contrast enhancement. The highest A z value of CNR and IVIM parameters occurred at a post-contrast b-value of 0 s/mm 2 and true diffusion (D). The highest qualitative evaluation occurred at a b-value of 800 s/mm 2 . The sensitivity and specificity, with a CNR of 100 or higher at a post-contrast b-value of 0 s/mm 2 and considered to be haemangioma, were 89% and 67% (<10 mm, 91%, 77%) respectively. The sensitivity and specificity, when D was higher than 1.4 × 10 -3 mm 2 /s, were 74% and 83% (<10 mm, 64%, 77%) respectively. The sensitivity and specificity of qualitative evaluation by enhanced DWI were 74% and 76% (<10 mm, 64%, 80%) respectively. The accuracy of the CNR was highest with b = 0; however, examination at high b-values had advantages in the qualitative evaluation of some small-size lesions. © 2016 The Royal Australian and New Zealand College of Radiologists.
[Effect of vibration caused by time-varying magnetic fields on diffusion-weighted MRI].
Ogura, Akio; Maeda, Fumie; Miyai, Akira; Hayashi, Kohji; Hongoh, Takaharu
2006-04-20
Diffusion-weighted images (DWIs) with high b-factor in the body are often used to detect and diagnose cancer at MRI. The echo planar imaging (EPI) sequence and high motion probing gradient pulse are used at diffusion weighted imaging, causing high table vibration. The purpose of this study was to assess whether the diffusion signal and apparent diffusion coefficient (ADC) values are influenced by this vibration because of time-varying magnetic fields. Two DWIs were compared. In one, phantoms were fixed on the MRI unit's table transmitting the vibration. In the other, phantoms were supported in air, in the absence of vibration. The phantoms called "solution phantoms" were made from agarose of a particular density. The phantoms called "jelly phantoms" were made from agarose that was heated. The diffusion signal and ADC value of each image were compared. The results showed that the signal of DWI units using the solution phantom was not affected by vibration. However, the signal of DWI and ADC were increased in the low-density jelly phantom as a result of vibration, causing the jelly phantom to vibrate. The DWIs of vibrating regions such as the breast maybe be subject to error. A countermeasure seems to be to support the region adequately.
Results for diffusion-weighted imaging with a fourth-channel gradient insert.
Feldman, Rebecca E; Scholl, Timothy J; Alford, Jamu K; Handler, William B; Harris, Chad T; Chronik, Blaine A
2011-12-01
Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis whole body gradients were used during image acquisition, but we designed and constructed an insert coil to perform diffusion encodings. We imaged three phantoms on a 3-T system with a range of diffusion coefficients. Using the insert gradient, we were able to encode b values of greater than 1300 s/mm(2) with an echo time of just 83 ms. Images obtained using the insert gradient had higher signal to noise ratios than those obtained using the whole body gradient: at 500 s/mm(2) there was a 18% improvement in signal to noise ratio, at 1000 s/mm(2) there was a 39% improvement in signal to noise ratio, and at 1350 s/mm(2) there was a 56% improvement in signal to noise ratio. Using the insert gradient, we were capable of doing diffusion encoding at high b values by using relatively short echo times. Copyright © 2011 Wiley Periodicals, Inc.
DIFFUSION-WEIGHTED IMAGING OF THE LIVER: TECHNIQUES AND APPLICATIONS
Lewis, Sara; Dyvorne, Hadrien; Cui, Yong; Taouli, Bachir
2014-01-01
SYNOPSIS Diffusion weighted MRI (DWI) is a technique that assesses the cellularity, tortuosity of the extracellular/extravascular space and cell membrane density based upon differences in water proton mobility in tissues. The strength of the diffusion weighting is reflected by the b-value. DWI using several b-values enables quantification of the apparent diffusion coefficient (ADC). DWI is increasingly employed in liver imaging for multiple reasons: it can add useful qualitative and quantitative information to conventional imaging sequences, it is acquired relatively quickly, it is easily incorporated into existing clinical protocols, and it is a non-contrast technique. DWI is useful for focal liver lesion detection and characterization, for the assessment of post-treatment tumor response and for evaluation of diffuse liver disease. ADC quantification can be used to characterize lesions as cystic/necrotic or solid and for predicting tumor response to therapy. Advanced diffusion methods such as IVIM (intravoxel incoherent motion) may have potential for detection, staging and evaluation of the progression of liver fibrosis and for liver lesion characterization. The lack of standardization of DWI technique including choice of b-values and sequence parameters has somewhat limited its widespread adoption. PMID:25086935
Afacan, Onur; Gholipour, Ali; Mulkern, Robert V; Barnewolt, Carol E; Estroff, Judy A; Connolly, Susan A; Parad, Richard B; Bairdain, Sigrid; Warfield, Simon K
2016-12-01
To evaluate the feasibility of using diffusion-weighted magnetic resonance imaging (DW-MRI) to assess the fetal lung apparent diffusion coefficient (ADC) at 3 Tesla (T). Seventy-one pregnant women (32 second trimester, 39 third trimester) were scanned with a twice-refocused Echo-planar diffusion-weighted imaging sequence with 6 different b-values in 3 orthogonal diffusion orientations at 3T. After each scan, a region-of-interest (ROI) mask was drawn to select a region in the fetal lung and an automated robust maximum likelihood estimation algorithm was used to compute the ADC parameter. The amount of motion in each scan was visually rated. When scans with unacceptable levels of motion were eliminated, the lung ADC values showed a strong association with gestational age (P < 0.01), increasing dramatically between 16 and 27 weeks and then achieving a plateau around 27 weeks. We show that to get reliable estimates of ADC values of fetal lungs, a multiple b-value acquisition, where motion is either corrected or considered, can be performed. J. Magn. Reson. Imaging 2016;44:1650-1655. © 2016 International Society for Magnetic Resonance in Medicine.
While, Peter T; Teruel, Jose R; Vidić, Igor; Bathen, Tone F; Goa, Pål Erik
2018-06-01
To explore the relationship between relative enhanced diffusivity (RED) and intravoxel incoherent motion (IVIM), as well as the impact of noise and the choice of intermediate diffusion weighting (b value) on the RED parameter. A mathematical derivation was performed to cast RED in terms of the IVIM parameters. Noise analysis and b value optimization was conducted by using Monte Carlo calculations to generate diffusion-weighted imaging data appropriate to breast and liver tissue at three different signal-to-noise ratios. RED was shown to be approximately linearly proportional to the IVIM parameter f, inversely proportional to D and to follow an inverse exponential decay with respect to D*. The choice of intermediate b value was shown to be important in minimizing the impact of noise on RED and in maximizing its discriminatory power. RED was shown to be essentially a reparameterization of the IVIM estimates for f and D obtained with three b values. RED imaging in the breast and liver should be performed with intermediate b values of 100 and 50 s/mm 2 , respectively. Future clinical studies involving RED should also estimate the IVIM parameters f and D using three b values for comparison.
Taimouri, Vahid; Afacan, Onur; Perez-Rossello, Jeannette M.; Callahan, Michael J.; Mulkern, Robert V.; Warfield, Simon K.; Freiman, Moti
2015-01-01
Purpose: To evaluate the effect of the spatially constrained incoherent motion (SCIM) method on improving the precision and robustness of fast and slow diffusion parameter estimates from diffusion-weighted MRI in liver and spleen in comparison to the independent voxel-wise intravoxel incoherent motion (IVIM) model. Methods: We collected diffusion-weighted MRI (DW-MRI) data of 29 subjects (5 healthy subjects and 24 patients with Crohn’s disease in the ileum). We evaluated parameters estimates’ robustness against different combinations of b-values (i.e., 4 b-values and 7 b-values) by comparing the variance of the estimates obtained with the SCIM and the independent voxel-wise IVIM model. We also evaluated the improvement in the precision of parameter estimates by comparing the coefficient of variation (CV) of the SCIM parameter estimates to that of the IVIM. Results: The SCIM method was more robust compared to IVIM (up to 70% in liver and spleen) for different combinations of b-values. Also, the CV values of the parameter estimations using the SCIM method were significantly lower compared to repeated acquisition and signal averaging estimated using IVIM, especially for the fast diffusion parameter in liver (CVIV IM = 46.61 ± 11.22, CVSCIM = 16.85 ± 2.160, p < 0.001) and spleen (CVIV IM = 95.15 ± 19.82, CVSCIM = 52.55 ± 1.91, p < 0.001). Conclusions: The SCIM method characterizes fast and slow diffusion more precisely compared to the independent voxel-wise IVIM model fitting in the liver and spleen. PMID:25832079
Wang, Yu; Zhang, Heng; Zhang, Ruzhi; Zhao, Zhoushe; Xu, Ziqian; Wang, Lei; Liu, Rongbo; Gao, Fabao
2017-01-01
To assess kidney damage in a rat model of type-2 diabetic nephropathy based on apparent diffusion coefficient (ADC) data obtained from ultra-high b-values and discuss its relationship to the expression of aquaporins (AQPs). This study was approved by the institutional Animal Care and Use Committee. Thirty male Sprague-Dawley rats were randomised into two groups: (1) untreated controls and (2) diabetes mellitus (DM). All rats underwent diffusion-weighted imaging (DWI) with 18 b-values (0-4500 s/mm 2 ). Maps of low ADC (ADC low ), standard ADC (ADC st ) and ultra-high ADC (ADC uh ) were calculated from low b-values (0-200 s/mm 2 ), standard b-values (300-1500 s/mm 2 ) and ultra-high b-values (1700-4500 s/mm 2 ), respectively. The expression of AQPs in the kidneys was studied using immunohistochemistry. Laboratory parameters of diabetic and kidney functions, ADC low , ADC st , ADC uh , and the optical density (OD) of AQP expression in the two groups were compared using an independent t test. Correlations between ADCs and the OD of AQP expression were evaluated by Pearson's correlation analysis. ADC uh were significantly higher in the cortex (CO), outer stripe of the outer medulla (OS) and inner stripe of the outer medulla (IS), and the OD values of AQ-2 were significantly higher in the OS, IS and inner medulla (IM) in DM animals compared with control animals. ADC uh and OD values of AQP-2 expression were positively correlated in the OS, IS and IM of the kidney. ADC uh may work as useful metrics for early detection of kidney damage in diabetic nephropathy and may be associated with AQP-2 expression.
Iima, Mami; Kataoka, Masako; Kanao, Shotaro; Kawai, Makiko; Onishi, Natsuko; Koyasu, Sho; Murata, Katsutoshi; Ohashi, Akane; Sakaguchi, Rena; Togashi, Kaori
2018-01-01
We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with breast lesions (seven malignant, eight benign; one patient had bilateral lesions) were recruited in this prospective study (approved by the Internal Review Board). Diffusion-weighted MRI was performed with 16 b-values (0-2500 s/mm2 with one number of excitations [NEX]) and five b-values (0-2500 s/mm2, 3 NEX), using a 3T breast MRI. Intravoxel incoherent motion (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm2 [ADC0] and kurtosis [K]) parameters were estimated from IVIM and Kurtosis models using 16 b-values, and synthetic apparent diffusion coefficient (sADC) values were obtained from two key b-values. The variabilities between and within subjects and between different diffusion acquisition methods were estimated. There were no statistical differences in ADC0, K, or sADC values between the different b-values or NEX. A good agreement of diffusion parameters was observed between 16 b-values (one NEX), five b-values (one NEX), and five b-values (three NEX) in normal breast tissue or breast lesions. Insufficient agreement was observed for IVIM parameters. There were no statistical differences in the non-Gaussian diffusion MRI estimated values obtained from a different number of b-values or excitations in normal breast tissue or breast lesions. These data suggest that a limited MRI protocol using a few b-values might be relevant in a clinical setting for the estimation of non-Gaussian diffusion MRI parameters in normal breast tissue and breast lesions.
Kataoka, Masako; Kanao, Shotaro; Kawai, Makiko; Onishi, Natsuko; Koyasu, Sho; Murata, Katsutoshi; Ohashi, Akane; Sakaguchi, Rena; Togashi, Kaori
2018-01-01
We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with breast lesions (seven malignant, eight benign; one patient had bilateral lesions) were recruited in this prospective study (approved by the Internal Review Board). Diffusion-weighted MRI was performed with 16 b-values (0–2500 s/mm2 with one number of excitations [NEX]) and five b-values (0–2500 s/mm2, 3 NEX), using a 3T breast MRI. Intravoxel incoherent motion (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm2 [ADC0] and kurtosis [K]) parameters were estimated from IVIM and Kurtosis models using 16 b-values, and synthetic apparent diffusion coefficient (sADC) values were obtained from two key b-values. The variabilities between and within subjects and between different diffusion acquisition methods were estimated. There were no statistical differences in ADC0, K, or sADC values between the different b-values or NEX. A good agreement of diffusion parameters was observed between 16 b-values (one NEX), five b-values (one NEX), and five b-values (three NEX) in normal breast tissue or breast lesions. Insufficient agreement was observed for IVIM parameters. There were no statistical differences in the non-Gaussian diffusion MRI estimated values obtained from a different number of b-values or excitations in normal breast tissue or breast lesions. These data suggest that a limited MRI protocol using a few b-values might be relevant in a clinical setting for the estimation of non-Gaussian diffusion MRI parameters in normal breast tissue and breast lesions. PMID:29494639
Fukukura, Yoshihiko; Shindo, Toshikazu; Hakamada, Hiroto; Takumi, Koji; Umanodan, Tomokazu; Nakajo, Masanori; Kamimura, Kiyoshisa; Umanodan, Aya; Ideue, Junnichi; Yoshiura, Takashi
2016-10-01
To determine the optimal b-value of 3.0-T diffusion-weighted imaging (DWI) for visualizing pancreatic adenocarcinomas Fifty-five patients with histologically confirmed pancreatic adenocarcinoma underwent DWI with different b-values (b = 500, 1000, 1500, and 2000 s/mm(2)) at 3.0 T. For each b-value, we retrospectively evaluated DWI findings of pancreatic adenocarcinomas (clear hyperintensity relative to the surrounding pancreas, hyperintensity with an unclear distal border, and isointensity) and image quality, and measured tumour-to-pancreas signal intensity (SI) ratios. DWI findings, image quality, and tumour-to-pancreas SI ratios were compared between the four b-values. There was a significantly higher incidence of tumours showing clear hyperintensity on DWI with b-value of 1500 s/mm(2) than on that with b-value of 1000 s/mm(2) (P < 0.001), and on DWI with b-value of 1000 s/mm(2) than on that with b-value of 500 s/mm(2) (P < 0.001). The tumour-to-distal pancreas SI ratio was higher with b-value of 1500 s/mm(2) than with b-value of 1000 s/mm(2) (P < 0.001), and with b-value of 1000 s/mm(2) than with b-value of 500 s/mm(2) (P < 0.001). A lower image quality was obtained at increasing b-values (P < 0.001); the lowest scores were observed with b-value of 2000 s/mm(2). The use of b = 1500 s/mm(2) for 3.0-T DWI can improve the delineation of pancreatic adenocarcinomas. • Diffusion-weighted imaging (DWI) has been used for diagnosing pancreatic adenocarcinoma • The techniques for DWI, including the choice of b-values, vary considerably • DWI often fails to delineate pancreatic adenocarcinomas because of hyperintense pancreas • DWI with a higher b-value can improve the tumour delineation • The lowest image quality was obtained on DWI with b-value = 2000 s/mm (2).
Zubkov, Mikhail; Stait-Gardner, Timothy; Price, William S
2014-06-01
Precise NMR diffusion measurements require detailed knowledge of the cumulative dephasing effect caused by the numerous gradient pulses present in most NMR pulse sequences. This effect, which ultimately manifests itself as the diffusion-related NMR signal attenuation, is usually described by the b-value or the b-matrix in the case of multidirectional diffusion weighting, the latter being common in diffusion-weighted NMR imaging. Neglecting some of the gradient pulses introduces an error in the calculated diffusion coefficient reaching in some cases 100% of the expected value. Therefore, ensuring the b-matrix calculation includes all the known gradient pulses leads to significant error reduction. Calculation of the b-matrix for simple gradient waveforms is rather straightforward, yet it grows cumbersome when complexly shaped and/or numerous gradient pulses are introduced. Making three broad assumptions about the gradient pulse arrangement in a sequence results in an efficient framework for calculation of b-matrices as well providing some insight into optimal gradient pulse placement. The framework allows accounting for the diffusion-sensitising effect of complexly shaped gradient waveforms with modest computational time and power. This is achieved by using the b-matrix elements of the simple unmodified pulse sequence and minimising the integration of the complexly shaped gradient waveform in the modified sequence. Such re-evaluation of the b-matrix elements retains all the analytical relevance of the straightforward approach, yet at least halves the amount of symbolic integration required. The application of the framework is demonstrated with the evaluation of the expression describing the diffusion-sensitizing effect, caused by different bipolar gradient pulse modules. Copyright © 2014 Elsevier Inc. All rights reserved.
Iwashita, Koya; Hirai, Toshinori; Kitajima, Mika; Shigematsu, Yoshinori; Uetani, Hiroyuki; Iryo, Yasuhiko; Azuma, Minako; Hayashida, Eri; Ando, Yukio; Murakami, Ryuji; Yamashita, Yasuyuki
2013-01-01
The purpose of this study was to determine how the gray-to-white matter contrast in healthy subjects changes on high-b-value diffusion-weighted imaging (DWI) acquired at 3 T and evaluate whether high-b-value DWI at 3 T is useful for the detection of cortical lesions in inflammatory brain diseases. Ten healthy volunteers underwent DWI at b = 1000, 2000, 3000, 4000, and 5000 s/mm(2) on a 3-T MRI unit. On DW images, 1 radiologist performed region-of-interest measurements of the signal intensity of 8 gray matter structures. The gray-to-white matter contrast ratio (GWCR) was calculated. Ten patients with inflammatory cortical lesions were also included. All patients underwent conventional MRI and DWI at b = 1000 and 3000 s/mm(2). Using a 4-point grading system, 2 radiologists independently assessed the presence of additional information on DW images compared with fluid-attenuated inversion recovery images. Interobserver agreement was assessed by κ statistics. In the healthy subjects, the b value increased as the GWCR decreased in all evaluated gray matter structures. On DW images acquired at b = 3000 s/mm(2), mean GWCR was less than 1.0 in 7 of 8 structures. For both reviewers, DWI at b = 3000 s/mm(2) yielded significantly more additional information than did DWI at b = 1000 s/mm(2) (P < 0.05). Interobserver agreement for DWI at b = 1000 s/mm(2) and b = 3000 s/mm(2) was fair (κ = 0.35) and excellent (κ = 1.0), respectively. At 3-T DWI, the gray-to-white matter contrast in most gray matter structures reverses at b = 3000 s/mm. In the evaluation of cortical lesions in patients with inflammatory brain diseases, 3-T DWI at b = 3000 s/mm was more useful than b = 1000 s/mm(2).
b matrix errors in echo planar diffusion tensor imaging
Boujraf, Saïd; Luypaert, Robert; Osteaux, Michel
2001-01-01
Diffusion‐weighted magnetic resonance imaging (DW‐MRI) is a recognized tool for early detection of infarction of the human brain. DW‐MRI uses the signal loss associated with the random thermal motion of water molecules in the presence of magnetic field gradients to derive parameters that reflect the translational mobility of the water molecules in tissues. If diffusion‐weighted images with different values of b matrix are acquired during one individual investigation, it is possible to calculate apparent diffusion coefficient maps that are the elements of the diffusion tensor. The diffusion tensor elements represent the apparent diffusion coefficient of protons of water molecules in each pixel in the corresponding sample. The relation between signal intensity in the diffusion‐weighted images, diffusion tensor, and b matrix is derived from the Bloch equations. Our goal is to establish the magnitude of the error made in the calculation of the elements of the diffusion tensor when the imaging gradients are ignored. PACS number(s): 87.57. –s, 87.61.–c PMID:11602015
Bai, Yan; Lin, Yusong; Tian, Jie; Shi, Dapeng; Cheng, Jingliang; Haacke, E. Mark; Hong, Xiaohua; Ma, Bo; Zhou, Jinyuan
2016-01-01
Purpose To quantitatively compare the potential of various diffusion parameters obtained from monoexponential, biexponential, and stretched exponential diffusion-weighted imaging models and diffusion kurtosis imaging in the grading of gliomas. Materials and Methods This study was approved by the local ethics committee, and written informed consent was obtained from all subjects. Both diffusion-weighted imaging and diffusion kurtosis imaging were performed in 69 patients with pathologically proven gliomas by using a 3-T magnetic resonance (MR) imaging unit. An isotropic apparent diffusion coefficient (ADC), true ADC, pseudo-ADC, and perfusion fraction were calculated from diffusion-weighted images by using a biexponential model. A water molecular diffusion heterogeneity index and distributed diffusion coefficient were calculated from diffusion-weighted images by using a stretched exponential model. Mean diffusivity, fractional anisotropy, and mean kurtosis were calculated from diffusion kurtosis images. All values were compared between high-grade and low-grade gliomas by using a Mann-Whitney U test. Receiver operating characteristic and Spearman rank correlation analysis were used for statistical evaluations. Results ADC, true ADC, perfusion fraction, water molecular diffusion heterogeneity index, distributed diffusion coefficient, and mean diffusivity values were significantly lower in high-grade gliomas than in low-grade gliomas (U = 109, 56, 129, 6, 206, and 229, respectively; P < .05). Pseudo-ADC and mean kurtosis values were significantly higher in high-grade gliomas than in low-grade gliomas (U = 98 and 8, respectively; P < .05). Both water molecular diffusion heterogeneity index (area under the receiver operating characteristic curve [AUC] = 0.993) and mean kurtosis (AUC = 0.991) had significantly greater AUC values than ADC (AUC = 0.866), mean diffusivity (AUC = 0.722), and fractional anisotropy (AUC = 0.500) in the differentiation of low-grade and high-grade gliomas (P < .05). Conclusion Water molecular diffusion heterogeneity index and mean kurtosis values may provide additional information and improve the grading of gliomas compared with conventional diffusion parameters. © RSNA, 2015 Online supplemental material is available for this article. PMID:26230975
Evaluation of non-Gaussian diffusion in cardiac MRI.
McClymont, Darryl; Teh, Irvin; Carruth, Eric; Omens, Jeffrey; McCulloch, Andrew; Whittington, Hannah J; Kohl, Peter; Grau, Vicente; Schneider, Jürgen E
2017-09-01
The diffusion tensor model assumes Gaussian diffusion and is widely applied in cardiac diffusion MRI. However, diffusion in biological tissue deviates from a Gaussian profile as a result of hindrance and restriction from cell and tissue microstructure, and may be quantified better by non-Gaussian modeling. The aim of this study was to investigate non-Gaussian diffusion in healthy and hypertrophic hearts. Thirteen rat hearts (five healthy, four sham, four hypertrophic) were imaged ex vivo. Diffusion-weighted images were acquired at b-values up to 10,000 s/mm 2 . Models of diffusion were fit to the data and ranked based on the Akaike information criterion. The diffusion tensor was ranked best at b-values up to 2000 s/mm 2 but reflected the signal poorly in the high b-value regime, in which the best model was a non-Gaussian "beta distribution" model. Although there was considerable overlap in apparent diffusivities between the healthy, sham, and hypertrophic hearts, diffusion kurtosis and skewness in the hypertrophic hearts were more than 20% higher in the sheetlet and sheetlet-normal directions. Non-Gaussian diffusion models have a higher sensitivity for the detection of hypertrophy compared with the Gaussian model. In particular, diffusion kurtosis may serve as a useful biomarker for characterization of disease and remodeling in the heart. Magn Reson Med 78:1174-1186, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Multi-Shell Hybrid Diffusion Imaging (HYDI) at 7 Tesla in TgF344-AD Transgenic Alzheimer Rats.
Daianu, Madelaine; Jacobs, Russell E; Weitz, Tara M; Town, Terrence C; Thompson, Paul M
2015-01-01
Diffusion weighted imaging (DWI) is widely used to study microstructural characteristics of the brain. Diffusion tensor imaging (DTI) and high-angular resolution imaging (HARDI) are frequently used in radiology and neuroscience research but can be limited in describing the signal behavior in composite nerve fiber structures. Here, we developed and assessed the benefit of a comprehensive diffusion encoding scheme, known as hybrid diffusion imaging (HYDI), composed of 300 DWI volumes acquired at 7-Tesla with diffusion weightings at b = 1000, 3000, 4000, 8000 and 12000 s/mm2 and applied it in transgenic Alzheimer rats (line TgF344-AD) that model the full clinico-pathological spectrum of the human disease. We studied and visualized the effects of the multiple concentric "shells" when computing three distinct anisotropy maps-fractional anisotropy (FA), generalized fractional anisotropy (GFA) and normalized quantitative anisotropy (NQA). We tested the added value of the multi-shell q-space sampling scheme, when reconstructing neural pathways using mathematical frameworks from DTI and q-ball imaging (QBI). We show a range of properties of HYDI, including lower apparent anisotropy when using high b-value shells in DTI-based reconstructions, and increases in apparent anisotropy in QBI-based reconstructions. Regardless of the reconstruction scheme, HYDI improves FA-, GFA- and NQA-aided tractography. HYDI may be valuable in human connectome projects and clinical research, as well as magnetic resonance research in experimental animals.
Multi-Shell Hybrid Diffusion Imaging (HYDI) at 7 Tesla in TgF344-AD Transgenic Alzheimer Rats
Daianu, Madelaine; Jacobs, Russell E.; Weitz, Tara M.; Town, Terrence C.; Thompson, Paul M.
2015-01-01
Diffusion weighted imaging (DWI) is widely used to study microstructural characteristics of the brain. Diffusion tensor imaging (DTI) and high-angular resolution imaging (HARDI) are frequently used in radiology and neuroscience research but can be limited in describing the signal behavior in composite nerve fiber structures. Here, we developed and assessed the benefit of a comprehensive diffusion encoding scheme, known as hybrid diffusion imaging (HYDI), composed of 300 DWI volumes acquired at 7-Tesla with diffusion weightings at b = 1000, 3000, 4000, 8000 and 12000 s/mm2 and applied it in transgenic Alzheimer rats (line TgF344-AD) that model the full clinico-pathological spectrum of the human disease. We studied and visualized the effects of the multiple concentric “shells” when computing three distinct anisotropy maps–fractional anisotropy (FA), generalized fractional anisotropy (GFA) and normalized quantitative anisotropy (NQA). We tested the added value of the multi-shell q-space sampling scheme, when reconstructing neural pathways using mathematical frameworks from DTI and q-ball imaging (QBI). We show a range of properties of HYDI, including lower apparent anisotropy when using high b-value shells in DTI-based reconstructions, and increases in apparent anisotropy in QBI-based reconstructions. Regardless of the reconstruction scheme, HYDI improves FA-, GFA- and NQA-aided tractography. HYDI may be valuable in human connectome projects and clinical research, as well as magnetic resonance research in experimental animals. PMID:26683657
Sokmen, Bedriye Koyuncu; Sokmen, Dogukan; Ucar, Nese; Ozkurt, Huseyin; Simsek, Abdulmuttalip
2017-12-31
Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR) images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC) values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1) (n = 20) (Stage T1c-T2a, PSA < 10 ng/ml, Gleason Score < 7), moderate-risk (Group 2) (n = 18) (Stage T1b-T2c, PSA = 10-20 ng/ml, Gleason Score = 7) and high-risk (Group 3) (n = 22) (Stage > T3a, PSA > 20 ng/ml, Gleason Score > 7). Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. ADC values of the cases in Group 3 were lower than those of the other groups (p < 0.001). ADC values of the areas without malignancy did not differ significantly between groups (p > 0.05). Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p < 0.001). In tumors with higher Gleason scores, lower ADC values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.
Budjan, Johannes; Sauter, Elke A; Zoellner, Frank G; Lemke, Andreas; Wambsganss, Jens; Schoenberg, Stefan O; Attenberger, Ulrike I
2018-01-01
Background Functional techniques like diffusion-weighted imaging (DWI) are gaining more and more importance in liver magnetic resonance imaging (MRI). Diffusion kurtosis imaging (DKI) is an advanced technique that might help to overcome current limitations of DWI. Purpose To evaluate DKI for the differentiation of hepatic lesions in comparison to conventional DWI at 3 Tesla. Material and Methods Fifty-six consecutive patients were examined using a routine abdominal MR protocol at 3 Tesla which included DWI with b-values of 50, 400, 800, and 1000 s/mm 2 . Apparent diffusion coefficient maps were calculated applying a standard mono-exponential fit, while a non-Gaussian kurtosis fit was used to obtain DKI maps. ADC as well as Kurtosis-corrected diffusion ( D) values were quantified by region of interest analysis and compared between lesions. Results Sixty-eight hepatic lesions (hepatocellular carcinoma [HCC] [n = 25]; hepatic adenoma [n = 4], cysts [n = 18]; hepatic hemangioma [HH] [n = 18]; and focal nodular hyperplasia [n = 3]) were identified. Differentiation of malignant and benign lesions was possible based on both DWI ADC as well as DKI D-values ( P values were in the range of 0.04 to < 0.0001). Conclusion In vivo abdominal DKI calculated using standard b-values is feasible and enables quantitative differentiation between malignant and benign liver lesions. Assessment of conventional ADC values leads to similar results when using b-values below 1000 s/mm 2 for DKI calculation.
Deep Learning Role in Early Diagnosis of Prostate Cancer
Reda, Islam; Khalil, Ashraf; Elmogy, Mohammed; Abou El-Fetouh, Ahmed; Shalaby, Ahmed; Abou El-Ghar, Mohamed; Elmaghraby, Adel; Ghazal, Mohammed; El-Baz, Ayman
2018-01-01
The objective of this work is to develop a computer-aided diagnostic system for early diagnosis of prostate cancer. The presented system integrates both clinical biomarkers (prostate-specific antigen) and extracted features from diffusion-weighted magnetic resonance imaging collected at multiple b values. The presented system performs 3 major processing steps. First, prostate delineation using a hybrid approach that combines a level-set model with nonnegative matrix factorization. Second, estimation and normalization of diffusion parameters, which are the apparent diffusion coefficients of the delineated prostate volumes at different b values followed by refinement of those apparent diffusion coefficients using a generalized Gaussian Markov random field model. Then, construction of the cumulative distribution functions of the processed apparent diffusion coefficients at multiple b values. In parallel, a K-nearest neighbor classifier is employed to transform the prostate-specific antigen results into diagnostic probabilities. Finally, those prostate-specific antigen–based probabilities are integrated with the initial diagnostic probabilities obtained using stacked nonnegativity constraint sparse autoencoders that employ apparent diffusion coefficient–cumulative distribution functions for better diagnostic accuracy. Experiments conducted on 18 diffusion-weighted magnetic resonance imaging data sets achieved 94.4% diagnosis accuracy (sensitivity = 88.9% and specificity = 100%), which indicate the promising results of the presented computer-aided diagnostic system. PMID:29804518
Lee, Minsu; Shin, Su-Jin; Oh, Young Taik; Jung, Dae Chul; Cho, Nam Hoon; Choi, Young Deuk; Park, Sung Yoon
2017-09-01
To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. • Accuracy of fusion MRI was 79.0% for T stage ≥2 in bladder cancer. • AUC of fusion MRI was 0.793 for T stage ≥2 in bladder cancer. • Diagnostic performance of fusion MRI was comparable with T2WI plus DWI. • As a non-contrast MRI technique, fusion MRI is useful for bladder cancer.
Joint groupwise registration and ADC estimation in the liver using a B-value weighted metric.
Sanz-Estébanez, Santiago; Rabanillo-Viloria, Iñaki; Royuela-Del-Val, Javier; Aja-Fernández, Santiago; Alberola-López, Carlos
2018-02-01
The purpose of this work is to develop a groupwise elastic multimodal registration algorithm for robust ADC estimation in the liver on multiple breath hold diffusion weighted images. We introduce a joint formulation to simultaneously solve both the registration and the estimation problems. In order to avoid non-reliable transformations and undesirable noise amplification, we have included appropriate smoothness constraints for both problems. Our metric incorporates the ADC estimation residuals, which are inversely weighted according to the signal content in each diffusion weighted image. Results show that the joint formulation provides a statistically significant improvement in the accuracy of the ADC estimates. Reproducibility has also been measured on real data in terms of the distribution of ADC differences obtained from different b-values subsets. The proposed algorithm is able to effectively deal with both the presence of motion and the geometric distortions, increasing accuracy and reproducibility in diffusion parameters estimation. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Nezzo, M; Di Trani, M G; Caporale, A; Miano, R; Mauriello, A; Bove, P; Capuani, S; Manenti, G
2016-10-01
To test the potential ability of mean diffusivity (MD) and fractional anisotropy (FA) in discriminating between PCa of grade group (GG) 1&2, and GGs≥3. Diffusion Tensor Imaging (DTI) experiments at 3T in a cohort of 38 patients with PCa (fifty lesions in total) were performed, by using different diffusion weights (b values) up to 2500s/mm(2). Gleason score (GS) and GG data were correlated with DTI parameters (MD and FA) estimated in PCa. The relation between DTI measures and GS was tested by the linear correlation analysis (Pearson's coefficient). One-way analysis of variance to check the statistical significance of the difference between GG 1&2 and GGs 3, 4, 5, ≥3 was used. Results were reported for each of the three b-values ranges: 0-800s/mm(2), 0-1500s/mm(2), 0-2500s/mm(2). A negative correlation was found between MD and GS. The highest linear correlation was observed when the fit was performed with data acquired in the b-values range 0-2500s/mm(2). MD values were significantly different between GG 1&2 and GG=3 and between GG 1&2 and GG ≥3. Moreover this difference is better defined when high b values (higher than b=800s/mm(2)) are used. The specificity, sensitivity and accuracy in the discrimination between GG 1&2 and GG=3 were: 90%, 66.7% and 82.4%, respectively when MD was estimated in the b-values range 0-2500s/mm(2) while these values were 85%, 58.3% and 78.4% when MD was estimated in the b-values range 0-800s/mm(2). Conversely FA did not discriminate between GG 1&2 and GG ≥3, at any investigated b-values range. This study suggests that MD estimation in PCa, obtained from DTI acquired at high b-values, can contribute to the diagnosis and grading of prostate cancer while FA is not a useful parameter for this purpose. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ribot, Emeline J; Trotier, Aurélien J; Castets, Charles R; Dallaudière, Benjamin; Thiaudière, Eric; Franconi, Jean-Michel; Miraux, Sylvain
2016-02-01
The goal of this study was to develop a 3D diffusion weighted sequence for free breathing liver imaging in small animals at high magnetic field. Hepatic metastases were detected and the apparent diffusion coefficients (ADC) were measured. A 3D SE-EPI sequence was developed by (i) inserting a water-selective excitation radiofrequency pulse to suppress adipose tissue signal and (ii) bipolar diffusion gradients to decrease the sensitivity to respiration motion. Mice with hepatic metastases were imaged at 7T by applying b values from 200 to 1100 s/mm(2). 3D images with high spatial resolution (182 × 156 × 125 µm) were obtained in only 8 min 32 s. The modified DW-SE-EPI sequence allowed to obtain 3D abdominal images of healthy mice with fat SNR 2.5 times lower than without any fat suppression method and sharpness 2.8 times higher than on respiration-triggered images. Due to the high spatial resolution, the core and the periphery of disseminated hepatic metastases were differentiated at high b-values only, demonstrating the presence of edema and proliferating cells (with ADC of 2.65 × 10(-3) and 1.55 × 10(-3) mm(2)/s, respectively). Furthermore, these metastases were accurately distinguished from proliferating ones within the same animal at high b-values (mean ADC of 0.38 × 10(-3) mm(2)/s). Metastases of less than 1.7 mm(3) diameter were detected. The new 3D SE-EPI sequence enabled to obtain diffusion information within liver metastases. In addition of intra-metastasis heterogeneity, differences in diffusion were measured between metastases within an animal. This sequence could be used to obtain diffusion information at high magnetic field.
de Jong, Antoinette; Kwee, Thomas C; de Klerk, John MH; Adam, Judit A; de Keizer, Bart; Fijnheer, Rob; Kersten, Marie José; Ludwig, Inge; Jauw, Yvonne WS; Zijlstra, Josée M; den Bos, Indra C Pieters - Van; Stoker, Jaap; Hoekstra, Otto S; Nievelstein, Rutger AJ
2014-01-01
The purpose of this study was to determine the correlation between the 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) standardized uptake value (SUV) and the diffusion-weighted magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). Pretreatment FDG-PET and diffusion-weighted MRI of 21 patients with histologically proven DLBCL were prospectively analyzed. In each patient, maximum, mean and peak standardized uptake value (SUV) was measured in the lesion with visually highest FDG uptake and in the largest lesion. Mean ADC (ADCmean, calculated with b-values of 0 and 1000 s/mm2) was measured in the same lesions. Correlations between FDG-PET metrics (SUVmax, SUVmean, SUVpeak) and ADCmean were assessed using Pearson’s correlation coefficients. In the lesions with visually highest FDG uptake, no significant correlations were found between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.498, P=0.609 and P=0.595, respectively). In the largest lesions, there were no significant correlations either between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.992, P=0.843 and P=0.894, respectively). The results of this study indicate that the glycolytic rate as measured by FDG-PET and changes in water compartmentalization and water diffusion as measured by the ADC are independent biological phenomena in newly diagnosed DLBCL. Further studies are warranted to assess the complementary roles of these different imaging biomarkers in the evaluation and follow-up of DLBCL. PMID:24795837
Zeng, Qiang; Ling, Chenhan; Shi, Feina; Dong, Fei; Jiang, Biao; Zhang, Jianmin
2018-03-01
Glioma cells may infiltrate beyond the tumor margins revealed on conventional structural images. To investigate whether the presence of a glioma infiltration sign on high b-value diffusion-weighted imaging (DWI) can predict the prognosis of gliomas. Retrospective cohort. Fifty-two patients with gliomas (14 WHO grade II; 13 WHO grade III; 25 WHO grade IV). 3.0T, including a T 1 -weighted contrast-enhanced (T 1 w-CE) sequence, contrast-enhanced T 2 -flair sequence, and a DWI sequence. T 1 w-CE images and contrast-enhanced T 2 -flair images were used for identifying the tumor region for enhancing and nonenhancing gliomas, respectively. The glioma infiltration sign was defined as the presence of a peritumoral abnormal high signal region on DWI map, which was adjacent to the tumor region and had higher signal than surrounding areas. This sign was assessed on a high b-value DWI map with b = 3000 s/mm 2 . For patients with glioma infiltration sign, DWI3000 max , DWI1000 max , ADC3000 min , and ADC1000 min were measured by drawing a region of interest over the peritumoral abnormal high signal region. Survival analysis was conducted by using Cox regression. Glioma infiltration sign was observed in 28 (53.8%) patients. The occurrence rate of this sign was 92.0% in grade IV gliomas, 30.8% in grade III gliomas, and 7.1% in grade II gliomas. The glioma infiltration sign could independently predict both the progression-free survival (hazard ratio [HR], 95% confidence interval [CI] = 8.58 [3.19-23.03], P < 0.001) and overall survival (HR, 95% CI = 11.90 [3.41-41.55], P < 0.001) after adjustment. For patients with glioma infiltration sign, DWI3000 max (P = 0.005) and ADC3000 min (P = 0.008) were both independent predictors of overall survival after adjustment, while DWI1000 max and ADC1000 min were not. The glioma infiltration sign on high b-value DWI is an independent predictor of poor prognosis in glioma patients. High b-value DWI might be a convenient method to detect glioma infiltration. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Duerr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea
2014-09-01
The purpose of our study was to determine the optimum combination of b values for calculating the apparent diffusion coefficient (ADC) using a diffusion-weighted (DW) single-shot turbo spin-echo (TSE) sequence in the differentiation between acute benign and malignant vertebral body fractures. Twenty-six patients with osteoporotic (mean age, 69 years; range, 31.5-86.2 years) and 20 patients with malignant vertebral fractures (mean age, 63.4 years; range, 24.7-86.4 years) were studied. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW single-shot TSE sequence at different b values (100, 250, 400, and 600 s/mm(2)) was applied. On the DW images for each evaluated fracture, an ROI was manually adapted to the area of hyperintense signal intensity on STIR-hypointense signal on T1-weighted images. For each ROI, nine different combinations of two, three, and four b values were used to calculate the ADC using a least-squares algorithm. The Student t test and Mann-Whitney U test were used to determine significant differences between benign and malignant fractures. An ROC analysis and the Youden index were used to determine cutoff values for assessment of the highest sensitivity and specificity for the different ADC values. The positive (PPV) and negative predictive values (NPV) were also determined. All calculated ADCs (except the combination of b = 400 s/mm(2) and b = 600 s/mm(2)) showed statistically significant differences between benign and malignant vertebral body fractures, with benign fractures having higher ADCs than malignant ones. The use of higher b values resulted in lower ADCs than those calculated with low b values. The highest AUC (0.85) showed the ADCs calculated with b = 100 and 400 s/mm(2), and the second highest AUC (0.829) showed the ADCs calculated with b = 100, 250, and 400 s/mm(2). The Youden index with equal weight given to sensitivity and specificity suggests use of an ADC calculated with b = 100, 250, and 400 s/mm(2) (cutoff ADC, < 1.7 × 10(-3) mm(2)/s) to best diagnose malignancy (sensitivity, 85%; specificity, 84.6%; PPV, 81.0%; NPV, 88.0%). ADCs calculated with a combination of low to intermediate b values (b = 100, 250, and 400 s/mm(2)) provide the best diagnostic performance of a DW single-shot TSE sequence to differentiate acute benign and malignant vertebral body fractures.
NASA Astrophysics Data System (ADS)
Cho, Jae-Hwan; Lee, Hae-Kag; Yang, Han-Joon; Lee, Gui-Won; Park, Yong-Soon; Chung, Woon-Kwan
2013-01-01
In this study, the authors investigated whether periodically-rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted imaging (DWI) can remove magnetic susceptibility artifacts and compared apparent diffusion coefficient (ADC) values for PROPELLER DWI and the common echo planar (EP) DWI. Twenty patients that underwent brain MRI with a metal dental implant were selected. A 3.0T MR scanner was then used to obtain EP DWI, PROPELLER DWI, and corresponding apparent diffusion coefficient (ADC) maps for a b-value of 0 and 1,000 s/mm2. The frequencies of magnetic susceptibility artifacts in four parts of the brain (bilateral temporal lobes, pons, and orbit) were selected. In the ADC maps, we measured the ADC values of both sides of the temporal lobe and the pons. According to the study results, the frequency of magnetic susceptibility artifacts in PROPELLER DW images was lower than it was in EP DW images. In ADC maps, the ADC values of the bilateral temporal lobes and the pons were all higher in PROPELLER ADC maps than in EP ADC maps. Our findings show that when a high-field MRI machine is used, magnetic susceptibility artifacts can distort anatomical structures and produce high-intensity signals. Furthermore, our findings suggest that in many cases, PROPELLER DWI would be helpful in terms of achieving a correct diagnosis.
Hypercellularity Components of Glioblastoma Identified by High b-Value Diffusion-Weighted Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pramanik, Priyanka P.; Parmar, Hemant A.; Mammoser, Aaron G.
2015-07-15
Purpose: Use of conventional magnetic resonance imaging (MRI) for target definition may expose glioblastomas (GB) to inadequate radiation dose coverage of the nonenhanced hypercellular subvolume. This study aimed to develop a technique to identify the hypercellular components of GB by using high b-value diffusion-weighted imaging (DWI) and to investigate its relationship with the prescribed 95% isodose volume (PDV) and progression-free survival (PFS). Methods and Materials: Twenty-one patients with GB underwent chemoradiation therapy post-resection and biopsy. Radiation therapy (RT) treatment planning was based upon conventional MRI. Pre-RT DWIs were acquired in 3 orthogonal directions with b-values of 0, 1000, and 3000more » s/mm{sup 2}. Hypercellularity volume (HCV) was defined on the high b-value (3000 s/mm{sup 2}) DWI by a threshold method. Nonenhanced signified regions not covered by the Gd-enhanced gross tumor volume (GTV-Gd) on T1-weighted images. The PDV was used to evaluate spatial coverage of the HCV by the dose plan. Association between HCV and PFS or other clinical covariates were assessed using univariate proportional hazards regression models. Results: HCVs and nonenhanced HCVs varied from 0.58 to 67 cm{sup 3} (median: 9.8 cm{sup 3}) and 0.15 to 60 cm{sup 3} (median: 2.5 cm{sup 3}), respectively. Fourteen patients had incomplete dose coverage of the HCV, 6 of whom had >1 cm{sup 3} HCV missed by the 95% PDV (range: 1.01-25.4 cm{sup 3}). Of the 15 patients who progressed, 5 progressed earlier, within 6 months post-RT, and 10 patients afterward. Pre-RT HCVs within recurrent GTVs-Gd were 78% (range: 65%-89%) for the 5 earliest progressions but lower, 53% (range: 0%-85%), for the later progressions. HCV and nonenhanced HCV were significant negative prognostic indicators for PFS (P<.002 and P<.01, respectively). The hypercellularity subvolume not covered by the 95% PDV was a significant negative predictor for PFS (P<.05). Conclusions: High b-value DWI identifies the hypercellular components of GB and could aid in RT target volume definition. Future studies will allow us to investigate the role of high b-value DWI in identifying radiation boost volumes and diagnosing progression.« less
Zhang, Guangwen; Wang, Shuangshuang; Wen, Didi; Zhang, Jing; Wei, Xiaocheng; Ma, Wanling; Zhao, Weiwei; Wang, Mian; Wu, Guosheng; Zhang, Jinsong
2016-12-09
Water molecular diffusion in vivo tissue is much more complicated. We aimed to compare non-Gaussian diffusion models of diffusion-weighted imaging (DWI) including intra-voxel incoherent motion (IVIM), stretched-exponential model (SEM) and Gaussian diffusion model at 3.0 T MRI in patients with rectal cancer, and to determine the optimal model for investigating the water diffusion properties and characterization of rectal carcinoma. Fifty-nine consecutive patients with pathologically confirmed rectal adenocarcinoma underwent DWI with 16 b-values at a 3.0 T MRI system. DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models (IVIM-mono, IVIM-bi and SEM) on primary tumor and adjacent normal rectal tissue. Parameters of standard apparent diffusion coefficient (ADC), slow- and fast-ADC, fraction of fast ADC (f), α value and distributed diffusion coefficient (DDC) were generated and compared between the tumor and normal tissues. The SEM exhibited the best fitting results of actual DWI signal in rectal cancer and the normal rectal wall (R 2 = 0.998, 0.999 respectively). The DDC achieved relatively high area under the curve (AUC = 0.980) in differentiating tumor from normal rectal wall. Non-Gaussian diffusion models could assess tissue properties more accurately than the ADC derived Gaussian diffusion model. SEM may be used as a potential optimal model for characterization of rectal cancer.
2011-01-01
Purpose To theoretically develop and experimentally validate a formulism based on a fractional order calculus (FC) diffusion model to characterize anomalous diffusion in brain tissues measured with a twice-refocused spin-echo (TRSE) pulse sequence. Materials and Methods The FC diffusion model is the fractional order generalization of the Bloch-Torrey equation. Using this model, an analytical expression was derived to describe the diffusion-induced signal attenuation in a TRSE pulse sequence. To experimentally validate this expression, a set of diffusion-weighted (DW) images was acquired at 3 Tesla from healthy human brains using a TRSE sequence with twelve b-values ranging from 0 to 2,600 s/mm2. For comparison, DW images were also acquired using a Stejskal-Tanner diffusion gradient in a single-shot spin-echo echo planar sequence. For both datasets, a Levenberg-Marquardt fitting algorithm was used to extract three parameters: diffusion coefficient D, fractional order derivative in space β, and a spatial parameter μ (in units of μm). Using adjusted R-squared values and standard deviations, D, β and μ values and the goodness-of-fit in three specific regions of interest (ROI) in white matter, gray matter, and cerebrospinal fluid were evaluated for each of the two datasets. In addition, spatially resolved parametric maps were assessed qualitatively. Results The analytical expression for the TRSE sequence, derived from the FC diffusion model, accurately characterized the diffusion-induced signal loss in brain tissues at high b-values. In the selected ROIs, the goodness-of-fit and standard deviations for the TRSE dataset were comparable with the results obtained from the Stejskal-Tanner dataset, demonstrating the robustness of the FC model across multiple data acquisition strategies. Qualitatively, the D, β, and μ maps from the TRSE dataset exhibited fewer artifacts, reflecting the improved immunity to eddy currents. Conclusion The diffusion-induced signal attenuation in a TRSE pulse sequence can be described by an FC diffusion model at high b-values. This model performs equally well for data acquired from the human brain tissues with a TRSE pulse sequence or a conventional Stejskal-Tanner sequence. PMID:21509877
Gao, Qing; Srinivasan, Girish; Magin, Richard L; Zhou, Xiaohong Joe
2011-05-01
To theoretically develop and experimentally validate a formulism based on a fractional order calculus (FC) diffusion model to characterize anomalous diffusion in brain tissues measured with a twice-refocused spin-echo (TRSE) pulse sequence. The FC diffusion model is the fractional order generalization of the Bloch-Torrey equation. Using this model, an analytical expression was derived to describe the diffusion-induced signal attenuation in a TRSE pulse sequence. To experimentally validate this expression, a set of diffusion-weighted (DW) images was acquired at 3 Tesla from healthy human brains using a TRSE sequence with twelve b-values ranging from 0 to 2600 s/mm(2). For comparison, DW images were also acquired using a Stejskal-Tanner diffusion gradient in a single-shot spin-echo echo planar sequence. For both datasets, a Levenberg-Marquardt fitting algorithm was used to extract three parameters: diffusion coefficient D, fractional order derivative in space β, and a spatial parameter μ (in units of μm). Using adjusted R-squared values and standard deviations, D, β, and μ values and the goodness-of-fit in three specific regions of interest (ROIs) in white matter, gray matter, and cerebrospinal fluid, respectively, were evaluated for each of the two datasets. In addition, spatially resolved parametric maps were assessed qualitatively. The analytical expression for the TRSE sequence, derived from the FC diffusion model, accurately characterized the diffusion-induced signal loss in brain tissues at high b-values. In the selected ROIs, the goodness-of-fit and standard deviations for the TRSE dataset were comparable with the results obtained from the Stejskal-Tanner dataset, demonstrating the robustness of the FC model across multiple data acquisition strategies. Qualitatively, the D, β, and μ maps from the TRSE dataset exhibited fewer artifacts, reflecting the improved immunity to eddy currents. The diffusion-induced signal attenuation in a TRSE pulse sequence can be described by an FC diffusion model at high b-values. This model performs equally well for data acquired from the human brain tissues with a TRSE pulse sequence or a conventional Stejskal-Tanner sequence. Copyright © 2011 Wiley-Liss, Inc.
Larsen, Nis Elbrønd; Haack, Søren; Larsen, Lars Peter Skovgaard; Pedersen, Erik Morre
2013-10-01
Diffusion weighted imaging (DWI) of the liver suffers from low signal to noise making 3 Tesla (3 T) an attractive option, but 3 T data is scarce. It was the aim to study the influence of different b values and respiratory compensation methods (RCM) on the apparent diffusion coefficient (ADC) level and on ADC reproducibility at 3 T. Ten healthy volunteers and 12 patients with malignant liver lesions underwent repeated (2-22 days) breathhold, free-breathing and respiratory triggered DWI at 3 T using b values between 0 and 1,000 s/mm(2). The ADCs changed up to 150% in healthy livers and up to 48% in malignant lesions depending on b value combinations. Best ADC reproducibility in healthy livers were obtained with respiratory triggering (95% limits of agreement: ±0.12) and free-breathing (±0.14). In malignant lesions equivalent reproducibility was obtained with less RCM dependence. The use of a lower maximum b value (b = 500) decreased reproducibility (±0.14 to ±0.32) in both normal liver and malignant lesions. Large differences in absolute ADC values and reproducibility caused by varying combinations of clinically realistic b values were demonstrated. Different RCMs caused smaller differences. Lowering maximum b value to 500 increased limits of agreement up to a factor of two. Serial ADC changes larger than approximately 15% can be detected confidently on an individual basis in both malignant lesions and normal liver parenchyma at 3 T using appropriate b values and respiratory compensation.
Diffusion tensor magnetic resonance imaging of the pancreas.
Nissan, Noam; Golan, Talia; Furman-Haran, Edna; Apter, Sara; Inbar, Yael; Ariche, Arie; Bar-Zakay, Barak; Goldes, Yuri; Schvimer, Michael; Grobgeld, Dov; Degani, Hadassa
2014-01-01
To develop a diffusion-tensor-imaging (DTI) protocol that is sensitive to the complex diffusion and perfusion properties of the healthy and malignant pancreas tissues. Twenty-eight healthy volunteers and nine patients with pancreatic-ductal-adenocacinoma (PDAC), were scanned at 3T with T2-weighted and DTI sequences. Healthy volunteers were also scanned with multi-b diffusion-weighted-imaging (DWI), whereas a standard clinical protocol complemented the PDAC patients' scans. Image processing at pixel resolution yielded parametric maps of three directional diffusion coefficients λ1, λ2, λ3, apparent diffusion coefficient (ADC), and fractional anisotropy (FA), as well as a λ1-vector map, and a main diffusion-direction map. DTI measurements of healthy pancreatic tissue at b-values 0,500 s/mm² yielded: λ1 = (2.65±0.35)×10⁻³, λ2 = (1.87±0.22)×10⁻³, λ3 = (1.20±0.18)×10⁻³, ADC = (1.91±0.22)×10⁻³ (all in mm²/s units) and FA = 0.38±0.06. Using b-values of 100,500 s/mm² led to a significant reduction in λ1, λ2, λ3 and ADC (p<.0001) and a significant increase (p<0.0001) in FA. The reduction in the diffusion coefficients suggested a contribution of a fast intra-voxel-incoherent-motion (IVIM) component at b≤100 s/mm², which was confirmed by the multi-b DWI results. In PDACs, λ1, λ2, λ3 and ADC in both 0,500 s/mm² and 100,500 s/mm² b-values sets, as well as the reduction in these diffusion coefficients between the two sets, were significantly lower in comparison to the distal normal pancreatic tissue, suggesting higher cellularity and diminution of the fast-IVIM component in the cancer tissue. DTI using two reference b-values 0 and 100 s/mm² enabled characterization of the water diffusion and anisotropy of the healthy pancreas, taking into account a contribution of IVIM. The reduction in the diffusion coefficients of PDAC, as compared to normal pancreatic tissue, and the smaller change in these coefficients in PDAC when the reference b-value was modified from 0 to 100 s/mm², helped identifying the presence of malignancy.
Teruel, Jose R; Goa, Pål E; Sjøbakk, Torill E; Østlie, Agnes; Fjøsne, Hans E; Bathen, Tone F
2016-05-01
To compare "standard" diffusion weighted imaging, and diffusion tensor imaging (DTI) of 2(nd) and 4(th) -order for the differentiation of malignant and benign breast lesions. Seventy-one patients were imaged at 3 Tesla with a 16-channel breast coil. A diffusion weighted MRI sequence including b = 0 and b = 700 in 30 directions was obtained for all patients. The image data were fitted to three different diffusion models: isotropic model - apparent diffusion coefficient (ADC), 2(nd) -order tensor model (the standard model used for DTI) and a 4(th) -order tensor model, with increased degrees of freedom to describe anisotropy. The ability of the fitted parameters in the different models to differentiate between malignant and benign tumors was analyzed. Seventy-two breast lesions were analyzed, out of which 38 corresponded to malignant and 34 to benign tumors. ADC (using any model) presented the highest discriminative ability of malignant from benign tumors with a receiver operating characteristic area under the curve (AUC) of 0.968, and sensitivity and specificity of 94.1% and 94.7% respectively for a 1.33 × 10(-3) mm(2) /s cutoff. Anisotropy measurements presented high statistical significance between malignant and benign tumors (P < 0.001), but with lower discriminative ability of malignant from benign tumors than ADC (AUC of 0.896 and 0.897 for fractional anisotropy and generalized anisotropy respectively). Statistical significant difference was found between generalized anisotropy and fractional anisotropy for cancers (P < 0.001) but not for benign lesions (P = 0.87). While anisotropy parameters have the potential to provide additional value for breast applications as demonstrated in this study, ADC exhibited the highest differentiation power between malignant and benign breast tumors. © 2015 Wiley Periodicals, Inc.
Min, Qinghua; Shao, Kangwei; Zhai, Lulan; Liu, Wei; Zhu, Caisong; Yuan, Lixin; Yang, Jun
2015-02-07
Diffusion-weighted magnetic resonance imaging (DW-MRI) is different from conventional diagnostic methods and has the potential to delineate the microscopic anatomy of a target tissue or organ. The purpose of our study was to evaluate the value of DW-MRI in the diagnosis of benign and malignant breast masses, which would help the clinical surgeon to decide the scope and pattern of operation. A total of 52 female patients with palpable solid breast masses received breast MRI scans using routine sequences, dynamic contrast-enhanced imaging, and diffusion-weighted echo-planar imaging at b values of 400, 600, and 800 s/mm(2), respectively. Two regions of interest (ROIs) were plotted, with a smaller ROI for the highest signal and a larger ROI for the overall lesion. Apparent diffusion coefficient (ADC) values were calculated at three different b values for all detectable lesions and from two different ROIs. The sensitivity, specificity, positive predictive value, and positive likelihood ratio of DW-MRI were determined for comparison with histological results. A total of 49 (49/52, 94.2%) lesions were detected using DW-MRI, including 20 benign lesions (two lesions detected in the same patient) and 29 malignant lesions. Benign lesion had a higher mean ADC value than their malignant counterparts, regardless of b value. According to the receiver operating characteristic (ROC) curve, the smaller-range ROI was more effective in differentiation between benign and malignant lesions. The area under the ROC curve was the largest at a b value of 800 s/mm(2). With a threshold ADC value at 1.23 × 10(-3) mm(2)/s, DW-MRI achieved a sensitivity of 82.8%, specificity of 90.0%, positive predictive value of 92.3%, and positive likelihood ratio of 8.3 for differentiating benign and malignant lesions. DW-MRI is an accurate diagnostic tool for differentiation between benign and malignant breast lesions, with an optimal b value of 800 s/mm(2). A smaller-range ROI focusing on the highest signal has a better differential value.
The effects of noise in cardiac diffusion tensor imaging and the benefits of averaging complex data.
Scott, Andrew D; Nielles-Vallespin, Sonia; Ferreira, Pedro F; McGill, Laura-Ann; Pennell, Dudley J; Firmin, David N
2016-05-01
There is growing interest in cardiac diffusion tensor imaging (cDTI), but, unlike other diffusion MRI applications, there has been little investigation of the effects of noise on the parameters typically derived. One method of mitigating noise floor effects when there are multiple image averages, as in cDTI, is to average the complex rather than the magnitude data, but the phase contains contributions from bulk motion, which must be removed first. The effects of noise on the mean diffusivity (MD), fractional anisotropy (FA), helical angle (HA) and absolute secondary eigenvector angle (E2A) were simulated with various diffusion weightings (b values). The effect of averaging complex versus magnitude images was investigated. In vivo cDTI was performed in 10 healthy subjects with b = 500, 1000, 1500 and 2000 s/mm(2). A technique for removing the motion-induced component of the image phase present in vivo was implemented by subtracting a low-resolution copy of the phase from the original images before averaging the complex images. MD, FA, E2A and the transmural gradient in HA were compared for un-averaged, magnitude- and complex-averaged reconstructions. Simulations demonstrated an over-estimation of FA and MD at low b values and an under-estimation at high b values. The transition is relatively signal-to-noise ratio (SNR) independent and occurs at a higher b value for FA (b = 1000-1250 s/mm(2)) than MD (b ≈ 250 s/mm(2)). E2A is under-estimated at low and high b values with a transition at b ≈ 1000 s/mm(2), whereas the bias in HA is comparatively small. The under-estimation of FA and MD at high b values is caused by noise floor effects, which can be mitigated by averaging the complex data. Understanding the parameters of interest and the effects of noise informs the selection of the optimal b values. When complex data are available, they should be used to maximise the benefit from the acquisition of multiple averages. The combination of complex data is also a valuable step towards segmented acquisitions. Copyright © 2016 John Wiley & Sons, Ltd.
Bittencourt, Leonardo K; Attenberger, Ulrike I; Lima, Daniel; Strecker, Ralph; de Oliveira, Andre; Schoenberg, Stefan O; Gasparetto, Emerson L; Hausmann, Daniel
2014-01-01
AIM: To evaluate the impact of computed b = 1400 s/mm2 (C-b1400) vs measured b = 1400 s/mm2 (M-b1400) diffusion-weighted images (DWI) on lesion detection rate, image quality and quality of lesion demarcation using a modern 3T-MR system based on a small-field-of-view sequence (sFOV). METHODS: Thirty patients (PSA: 9.5 ± 8.7 ng/mL; 68 ± 12 years) referred for magnetic resonance imaging (MRI) of the prostate were enrolled in this study. All measurements were performed on a 3T MR system. For DWI, a single-shot EPI diffusion sequence (b = 0, 100, 400, 800 s/mm²) was utilized. C-b1400 was calculated voxelwise from the ADC and diffusion images. Additionally, M-b1400 was acquired for evaluation and comparison. Lesion detection rate and maximum lesion diameters were obtained and compared. Image quality and quality of lesion demarcation were rated according to a 5-point Likert-type scale. Ratios of lesion-to-bladder as well as prostate-to-bladder signal intensity (SI) were calculated to estimate the signal-to-noise-ratio (SNR). RESULTS: Twenty-four lesions were detected on M-b1400 images and compared to C-b1400 images. C-b1400 detected three additional cancer suspicious lesions. Overall image quality was rated significantly better and SI ratios were significantly higher on C-b1400 (2.3 ± 0.8 vs 3.1 ± 1.0, P < 0.001; 5.6 ± 1.8 vs 2.8 ± 0.9, P < 0.001). Comparison of lesion size showed no significant differences between C- and M-b1400 (P = 0.22). CONCLUSION: Combination of a high b-value extrapolation and sFOV may contribute to increase diagnostic accuracy of DWI without an increase of acquisition time, which may be useful to guide targeted prostate biopsies and to improve quality of multiparametric MRI (mMRI) especially under economical aspects in a private practice setting. PMID:24976938
Real Diffusion-Weighted MRI Enabling True Signal Averaging and Increased Diffusion Contrast
Eichner, Cornelius; Cauley, Stephen F; Cohen-Adad, Julien; Möller, Harald E; Turner, Robert; Setsompop, Kawin; Wald, Lawrence L
2015-01-01
This project aims to characterize the impact of underlying noise distributions on diffusion-weighted imaging. The noise floor is a well-known problem for traditional magnitude-based diffusion-weighted MRI (dMRI) data, leading to biased diffusion model fits and inaccurate signal averaging. Here, we introduce a total-variation-based algorithm to eliminate shot-to-shot phase variations of complex-valued diffusion data with the intention to extract real-valued dMRI datasets. The obtained real-valued diffusion data are no longer superimposed by a noise floor but instead by a zero-mean Gaussian noise distribution, yielding dMRI data without signal bias. We acquired high-resolution dMRI data with strong diffusion weighting and, thus, low signal-to-noise ratio. Both the extracted real-valued and traditional magnitude data were compared regarding signal averaging, diffusion model fitting and accuracy in resolving crossing fibers. Our results clearly indicate that real-valued diffusion data enables idealized conditions for signal averaging. Furthermore, the proposed method enables unbiased use of widely employed linear least squares estimators for model fitting and demonstrates an increased sensitivity to detect secondary fiber directions with reduced angular error. The use of phase-corrected, real-valued data for dMRI will therefore help to clear the way for more detailed and accurate studies of white matter microstructure and structural connectivity on a fine scale. PMID:26241680
Separation of extra- and intracellular metabolites using hyperpolarized 13C diffusion weighted MR
NASA Astrophysics Data System (ADS)
Koelsch, Bertram L.; Sriram, Renuka; Keshari, Kayvan R.; Leon Swisher, Christine; Van Criekinge, Mark; Sukumar, Subramaniam; Vigneron, Daniel B.; Wang, Zhen J.; Larson, Peder E. Z.; Kurhanewicz, John
2016-09-01
This work demonstrates the separation of extra- and intracellular components of glycolytic metabolites with diffusion weighted hyperpolarized 13C magnetic resonance spectroscopy. Using b-values of up to 15,000 s mm-2, a multi-exponential signal response was measured for hyperpolarized [1-13C] pyruvate and lactate. By fitting the fast and slow asymptotes of these curves, their extra- and intracellular weighted diffusion coefficients were determined in cells perfused in a MR compatible bioreactor. In addition to measuring intracellular weighted diffusion, extra- and intracellular weighted hyperpolarized 13C metabolites pools are assessed in real-time, including their modulation with inhibition of monocarboxylate transporters. These studies demonstrate the ability to simultaneously assess membrane transport in addition to enzymatic activity with the use of diffusion weighted hyperpolarized 13C MR. This technique could be an indispensible tool to evaluate the impact of microenvironment on the presence, aggressiveness and metastatic potential of a variety of cancers.
Novel Diffusion-Weighted MRI for High-Grade Prostate Cancer Detection
2017-10-01
AWARD NUMBER: W81XWH-15-1-0346 TITLE: Novel Diffusion-Weighted MRI for High -Grade Prostate Cancer Detection PRINCIPAL INVESTIGATOR: Michael Abern...Unlimited The views, opinions and/or findings contained in this report are those of the author(s) and should not be construed as an official Department of...Diffusion-Weighted MRI for High -Grade Prostate Cancer Detection 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-15-1-0346 5c. PROGRAM ELEMENT NUMBER 6
Göya, Cemil; Hamidi, Cihad; Bozkurt, Yaşar; Yavuz, Alpaslan; Kuday, Suzan; Gümüş, Hatice; Türkçü, Gül; Hattapoğlu, Salih; Bilici, Aslan
2015-07-01
Diffusion-weighted magnetic resonance imaging (DWI) is a widely-accepted diagnostic modality whose efficacy has been investigated by numerous past studies in the differentiation of malignant lesions from benign entities. The aim of this study was to evaluate the efficiency of diffusion-weighted magnetic resonance imaging in the characterization of renal lesions. Diagnostic accuracy study. A total of 137 patients with renal lesions were included in this study. The median apparent diffusion coefficient (ADC) values as well as the b 800 and b 1600 signal intensities of normal kidneys, solid components of mixed renal masses, and total cystic lesions were evaluated. There were significant differences between the ADC values of lesions and normal renal parenchyma, and between the ADC values of benign and malignant renal lesions on DWIs at b values of 800 and 1600 s/mm(2) (p<0.001 and p<0.001, respectively). There were significant differences between the ADC values of Bosniak Category 1 and 2 cysts and the ADC values of Bosniak Category 1 and 3 cysts on DWIs at b values of 800 s/mm(2) (p<0.001) and 1600 s/mm(2) (p<0.001). A cutoff value of 1.902 × 10(-3) mm(2)/s for the ADC with a b value of 800 s/mm(2) provided 88% sensitivity and 96% specificity for differentiation between benign and malignant renal lesions. A cutoff value of 1.623 × 10(-3) mm(2)/s for the ADC with a b value of 1600 s/mm(2) provided 79% sensitivity and 96% specificity (p<0.001) for the differentiation between benign and malignant renal lesions. Accurate assessment of renal masses is important for determining the necessity for surgical intervention. DWI provides additional value by differentiating benign from malignant renal tumors and can be added to routine kidney MRI protocols.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyagi, N; Wengler, K; Mazaheri, Y
2014-06-15
Purpose: Pseudodiffusion arises from the microcirculation of blood in the randomly oriented capillary network and contributes to the signal decay acquired using a multi-b value diffusion weighted (DW)-MRI sequence. This effect is more significant at low b-values and should be properly accounted for in apparent diffusion coefficient (ADC) calculations. The purpose of this study was to separate perfusion and diffusion component based on a biexponential and a segmented monoexponential model using IVIM analysis Methods. The signal attenuation is modeled as S(b) = S0[(1−f)exp(−bD) + fexp(−bD*)]. Fitting the biexponetial decay leads to the quantification of D, the true diffusion coefficient, D*,more » the pseudodiffusion coefficient, and f, the perfusion fraction. A nonlinear least squares fit and two segmented monoexponential models were used to derive the values for D, D*,‘and f. In the segmented approach b = 200 s/mm{sup 2} was used as the cut-off value for calculation of D. DW-MRI's of a rectum cancer patient were acquired before chemotherapy, before radiation therapy (RT), and 4 weeks into RT and were investigated as an example case. Results: Mean ADC for the tumor drawn on the DWI cases was 0.93, 1.0 and 1.13 10{sup −3}×mm{sup 2}/s before chemotherapy, before RT and 4 weeks into RT. The mean (D.10{sup −3} × mm{sup 2}/s, D* 10{sup −3} × mm{sup 2}/s, and f %) based on biexponential fit was (0.67, 18.6, and 27.2%), (0.72, 17.7, and 28.9%) and (0.83,15.1, and 30.7%) at these time points. The mean (D, D* f) based on segmented fit was (0.72, 10.5, and 12.1%), (0.72, 8.2, and 17.4%) and (.82, 8.1, 16.5%) Conclusion: ADC values are typically higher than true diffusion coefficients. For tumors with significant perfusion effect, ADC should be analyzed at higher b-values or separated from the perfusion component. Biexponential fit overestimates the perfusion fraction because of increased sensitivity to noise at low b-values.« less
Tamada, Tsutomu; Kanomata, Naoki; Sone, Teruki; Jo, Yoshimasa; Miyaji, Yoshiyuki; Higashi, Hiroki; Yamamoto, Akira; Ito, Katsuyoshi
2014-01-01
Objective The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. Materials and Methods The institutional review board approved this study and waived the requirement for informed consent. A total of 50 patients with prostate cancer (69 cancer foci; 48 in the PZ, 20 in the TZ, and one in whole prostate) who underwent multiparametric prostate MRI including DW-MRI (b values: 0, 1000 s/mm2 and 0, 2000 s/mm2) on a 3-T system were included. Lesion conspicuity score (LCS) using visual assessment (1 = invisible for surrounding normal site; 2 = slightly high intensity; 3 = moderately high; and 4 = very high) and tumor-normal signal intensity ratio (TNR) were assessed, and apparent diffusion coefficient (ADC, ×10−3 mm2/s) of the tumor regions and normal regions were measured. Results Mean LCS and TNR at 0, 2000 s/mm2 was significantly higher than those at 0, 1000 s/mm2 (p<0.001 for both). In addition, ADC at both 0, 1000 and 0, 2000 s/mm2 was found to distinguish intermediate or high risk cancer with Gleason score ≥7 from low risk cancer with Gleason score ≤6 (p<0.001 for both). Furthermore, ADC of tumor regions correlated with Gleason score at both 0, 1000 s/mm2 (ρ = −0.602; p<0.001) and 0, 2000 s/mm2 (ρ = −0.645; p<0.001). Conclusions For tumor conspicuity and characterization of prostate cancer on DW-MRI of 3-T MRI, b = 0, 2000 s/mm2 is more useful than b = 0, 1000 s/mm2. PMID:24802652
Tamada, Tsutomu; Kanomata, Naoki; Sone, Teruki; Jo, Yoshimasa; Miyaji, Yoshiyuki; Higashi, Hiroki; Yamamoto, Akira; Ito, Katsuyoshi
2014-01-01
The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. The institutional review board approved this study and waived the requirement for informed consent. A total of 50 patients with prostate cancer (69 cancer foci; 48 in the PZ, 20 in the TZ, and one in whole prostate) who underwent multiparametric prostate MRI including DW-MRI (b values: 0, 1000 s/mm2 and 0, 2000 s/mm2) on a 3-T system were included. Lesion conspicuity score (LCS) using visual assessment (1 = invisible for surrounding normal site; 2 = slightly high intensity; 3 = moderately high; and 4 = very high) and tumor-normal signal intensity ratio (TNR) were assessed, and apparent diffusion coefficient (ADC, ×10-3 mm2/s) of the tumor regions and normal regions were measured. Mean LCS and TNR at 0, 2000 s/mm2 was significantly higher than those at 0, 1000 s/mm2 (p<0.001 for both). In addition, ADC at both 0, 1000 and 0, 2000 s/mm2 was found to distinguish intermediate or high risk cancer with Gleason score ≥7 from low risk cancer with Gleason score ≤6 (p<0.001 for both). Furthermore, ADC of tumor regions correlated with Gleason score at both 0, 1000 s/mm2 (ρ = -0.602; p<0.001) and 0, 2000 s/mm2 (ρ = -0.645; p<0.001). For tumor conspicuity and characterization of prostate cancer on DW-MRI of 3-T MRI, b = 0, 2000 s/mm2 is more useful than b = 0, 1000 s/mm2.
Asbach, Patrick; Hein, Patrick A; Stemmer, Alto; Wagner, Moritz; Huppertz, Alexander; Hamm, Bernd; Taupitz, Matthias; Klessen, Christian
2008-01-01
To evaluate soft tissue contrast and image quality of a respiratory-triggered echo-planar imaging based diffusion-weighted sequence (EPI-DWI) with different b values for magnetic resonance imaging (MRI) of the liver. Forty patients were examined. Quantitative and qualitative evaluation of contrast was performed. Severity of artifacts and overall image quality in comparison with a T2w turbo spin-echo (T2-TSE) sequence were scored. The liver-spleen contrast was significantly higher (P < 0.05) for the EPI-DWI compared with the T2-TSE sequence (0.47 +/- 0.11 (b50); 0.48 +/- 0.13 (b300); 0.47 +/- 0.13 (b600) vs 0.38 +/- 0.11). Liver-lesion contrast strongly depends on the b value of the DWI sequence and decreased with higher b values (b50, 0.47 +/- 0.19; b300, 0.40 +/- 0.20; b600, 0.28 +/- 0.23). Severity of artifacts and overall image quality were comparable to the T2-TSE sequence when using a low b value (P > 0.05), artifacts increased and image quality decreased with higher b values (P < 0.05). Respiratory-triggered EPI-DWI of the liver is feasible because good image quality and favorable soft tissue contrast can be achieved.
Ginzburg, Irina
2017-01-01
Impact of the unphysical tangential advective-diffusion constraint of the bounce-back (BB) reflection on the impermeable solid surface is examined for the first four moments of concentration. Despite the number of recent improvements for the Neumann condition in the lattice Boltzmann method-advection-diffusion equation, the BB rule remains the only known local mass-conserving no-flux condition suitable for staircase porous geometry. We examine the closure relation of the BB rule in straight channel and cylindrical capillary analytically, and show that it excites the Knudsen-type boundary layers in the nonequilibrium solution for full-weight equilibrium stencil. Although the d2Q5 and d3Q7 coordinate schemes are sufficient for the modeling of isotropic diffusion, the full-weight stencils are appealing for their advanced stability, isotropy, anisotropy and anti-numerical-diffusion ability. The boundary layers are not covered by the Chapman-Enskog expansion around the expected equilibrium, but they accommodate the Chapman-Enskog expansion in the bulk with the closure relation of the bounce-back rule. We show that the induced boundary layers introduce first-order errors in two primary transport properties, namely, mean velocity (first moment) and molecular diffusion coefficient (second moment). As a side effect, the Taylor-dispersion coefficient (second moment), skewness (third moment), and kurtosis (fourth moment) deviate from their physical values and predictions of the fourth-order Chapman-Enskog analysis, even though the kurtosis error in pure diffusion does not depend on grid resolution. In two- and three-dimensional grid-aligned channels and open-tubular conduits, the errors of velocity and diffusion are proportional to the diagonal weight values of the corresponding equilibrium terms. The d2Q5 and d3Q7 schemes do not suffer from this deficiency in grid-aligned geometries but they cannot avoid it if the boundaries are not parallel to the coordinate lines. In order to vanish or attenuate the disparity of the modeled transport coefficients with the equilibrium weights without any modification of the BB rule, we propose to use the two-relaxation-times collision operator with free-tunable product of two eigenfunctions Λ. Two different values Λ_{v} and Λ_{b} are assigned for bulk and boundary nodes, respectively. The rationale behind this is that Λ_{v} is adjustable for stability, accuracy, or other purposes, while the corresponding Λ_{b}(Λ_{v}) controls the primary accommodation effects. Two distinguished but similar functional relations Λ_{b}(Λ_{v}) are constructed analytically: they preserve advection velocity in parabolic profile, exactly in the two-dimensional channel and very accurately in a three-dimensional cylindrical capillary. For any velocity-weight stencil, the (local) double-Λ BB scheme produces quasi-identical solutions with the (nonlocal) specular-forward reflection for first four moments in a channel. In a capillary, this strategy allows for the accurate modeling of the Taylor-dispersion and non-Gaussian effects. As illustrative example, it is shown that in the flow around a circular obstacle, the double-Λ scheme may also vanish the dependency of mean velocity on the velocity weight; the required value for Λ_{b}(Λ_{v}) can be identified in a few bisection iterations in given geometry. A positive solution for Λ_{b}(Λ_{v}) may not exist in pure diffusion, but a sufficiently small value of Λ_{b} significantly reduces the disparity in diffusion coefficient with the mass weight in ducts and in the presence of rectangular obstacles. Although Λ_{b} also controls the effective position of straight or curved boundaries, the double-Λ scheme deals with the lower-order effects. Its idea and construction may help understanding and amelioration of the anomalous, zero- and first-order behavior of the macroscopic solution in the presence of the bulk and boundary or interface discontinuities, commonly found in multiphase flow and heterogeneous transport.
NASA Astrophysics Data System (ADS)
Ginzburg, Irina
2017-01-01
Impact of the unphysical tangential advective-diffusion constraint of the bounce-back (BB) reflection on the impermeable solid surface is examined for the first four moments of concentration. Despite the number of recent improvements for the Neumann condition in the lattice Boltzmann method-advection-diffusion equation, the BB rule remains the only known local mass-conserving no-flux condition suitable for staircase porous geometry. We examine the closure relation of the BB rule in straight channel and cylindrical capillary analytically, and show that it excites the Knudsen-type boundary layers in the nonequilibrium solution for full-weight equilibrium stencil. Although the d2Q5 and d3Q7 coordinate schemes are sufficient for the modeling of isotropic diffusion, the full-weight stencils are appealing for their advanced stability, isotropy, anisotropy and anti-numerical-diffusion ability. The boundary layers are not covered by the Chapman-Enskog expansion around the expected equilibrium, but they accommodate the Chapman-Enskog expansion in the bulk with the closure relation of the bounce-back rule. We show that the induced boundary layers introduce first-order errors in two primary transport properties, namely, mean velocity (first moment) and molecular diffusion coefficient (second moment). As a side effect, the Taylor-dispersion coefficient (second moment), skewness (third moment), and kurtosis (fourth moment) deviate from their physical values and predictions of the fourth-order Chapman-Enskog analysis, even though the kurtosis error in pure diffusion does not depend on grid resolution. In two- and three-dimensional grid-aligned channels and open-tubular conduits, the errors of velocity and diffusion are proportional to the diagonal weight values of the corresponding equilibrium terms. The d2Q5 and d3Q7 schemes do not suffer from this deficiency in grid-aligned geometries but they cannot avoid it if the boundaries are not parallel to the coordinate lines. In order to vanish or attenuate the disparity of the modeled transport coefficients with the equilibrium weights without any modification of the BB rule, we propose to use the two-relaxation-times collision operator with free-tunable product of two eigenfunctions Λ . Two different values Λv and Λb are assigned for bulk and boundary nodes, respectively. The rationale behind this is that Λv is adjustable for stability, accuracy, or other purposes, while the corresponding Λb(Λv) controls the primary accommodation effects. Two distinguished but similar functional relations Λb(Λv) are constructed analytically: they preserve advection velocity in parabolic profile, exactly in the two-dimensional channel and very accurately in a three-dimensional cylindrical capillary. For any velocity-weight stencil, the (local) double-Λ BB scheme produces quasi-identical solutions with the (nonlocal) specular-forward reflection for first four moments in a channel. In a capillary, this strategy allows for the accurate modeling of the Taylor-dispersion and non-Gaussian effects. As illustrative example, it is shown that in the flow around a circular obstacle, the double-Λ scheme may also vanish the dependency of mean velocity on the velocity weight; the required value for Λb(Λv) can be identified in a few bisection iterations in given geometry. A positive solution for Λb(Λv) may not exist in pure diffusion, but a sufficiently small value of Λb significantly reduces the disparity in diffusion coefficient with the mass weight in ducts and in the presence of rectangular obstacles. Although Λb also controls the effective position of straight or curved boundaries, the double-Λ scheme deals with the lower-order effects. Its idea and construction may help understanding and amelioration of the anomalous, zero- and first-order behavior of the macroscopic solution in the presence of the bulk and boundary or interface discontinuities, commonly found in multiphase flow and heterogeneous transport.
Yuan, Jing; Yeung, David Ka Wai; Mok, Greta S P; Bhatia, Kunwar S; Wang, Yi-Xiang J; Ahuja, Anil T; King, Ann D
2014-01-01
To technically investigate the non-Gaussian diffusion of head and neck diffusion weighted imaging (DWI) at 3 Tesla and compare advanced non-Gaussian diffusion models, including diffusion kurtosis imaging (DKI), stretched-exponential model (SEM), intravoxel incoherent motion (IVIM) and statistical model in the patients with nasopharyngeal carcinoma (NPC). After ethics approval was granted, 16 patients with NPC were examined using DWI performed at 3T employing an extended b-value range from 0 to 1500 s/mm(2). DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models on primary tumor, metastatic node, spinal cord and muscle. Non-Gaussian parameter maps were generated and compared to apparent diffusion coefficient (ADC) maps in NPC. Diffusion in NPC exhibited non-Gaussian behavior at the extended b-value range. Non-Gaussian models achieved significantly better fitting of DWI signal than the mono-exponential model. Non-Gaussian diffusion coefficients were substantially different from mono-exponential ADC both in magnitude and histogram distribution. Non-Gaussian diffusivity in head and neck tissues and NPC lesions could be assessed by using non-Gaussian diffusion models. Non-Gaussian DWI analysis may reveal additional tissue properties beyond ADC and holds potentials to be used as a complementary tool for NPC characterization.
Zhang, Yuxin; Holmes, James; Rabanillo, Iñaki; Guidon, Arnaud; Wells, Shane; Hernando, Diego
2018-09-01
To evaluate the reproducibility of quantitative diffusion measurements obtained with reduced Field of View (rFOV) and Multi-shot EPI (msEPI) acquisitions, using single-shot EPI (ssEPI) as a reference. Diffusion phantom experiments, and prostate diffusion-weighted imaging in healthy volunteers and patients with known or suspected prostate cancer were performed across the three different sequences. Quantitative diffusion measurements of apparent diffusion coefficient, and diffusion kurtosis parameters (healthy volunteers), were obtained and compared across diffusion sequences (rFOV, msEPI, and ssEPI). Other possible confounding factors like b-value combinations and acquisition parameters were also investigated. Both msEPI and rFOV have shown reproducible quantitative diffusion measurements relative to ssEPI; no significant difference in ADC was observed across pulse sequences in the standard diffusion phantom (p = 0.156), healthy volunteers (p ≥ 0.12) or patients (p ≥ 0.26). The ADC values within the non-cancerous central gland and peripheral zone of patients were 1.29 ± 0.17 × 10 -3 mm 2 /s and 1.74 ± 0.23 × 10 -3 mm 2 /s respectively. However, differences in quantitative diffusion parameters were observed across different number of averages for rFOV, and across b-value groups and diffusion models for all the three sequences. Both rFOV and msEPI have the potential to provide high image quality with reproducible quantitative diffusion measurements in prostate diffusion MRI. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Perera, Dimuthu
Diffusion weighted (DW) Imaging is a non-invasive MR technique that provides information about the tissue microstructure using the diffusion of water molecules. The diffusion is generally characterized by the apparent diffusion coefficient (ADC) parametric map. The purpose of this study is to investigate in silico how the calculation of ADC is affected by image SNR, b-values, and the true tissue ADC. Also, to provide optimal parameter combination depending on the percentage accuracy and precision for prostate peripheral region cancer application. Moreover, to suggest parameter choices for any type of tissue, while providing the expected accuracy and precision. In this research DW images were generated assuming a mono-exponential signal model at two different b-values and for known true ADC values. Rician noise of different levels was added to the DWI images to adjust the image SNR. Using the two DWI images, ADC was calculated using a mono-exponential model for each set of b-values, SNR, and true ADC. 40,000 ADC data were collected for each parameter setting to determine the mean and the standard-deviation of the calculated ADC, as well as the percentage accuracy and precision with respect to the true ADC. The accuracy was calculated using the difference between known and calculated ADC. The precision was calculated using the standard-deviation of calculated ADC. The optimal parameters for a specific study was determined when both the percentage accuracy and precision were minimized. In our study, we simulated two true ADCs (ADC 0.00102 for tumor and 0.00180 mm2/s for normal prostate peripheral region tissue). Image SNR was varied from 2 to 100 and b-values were varied from 0 to 2000s/mm2. The results show that the percentage accuracy and percentage precision were minimized with image SNR. To increase SNR, 10 signal-averagings (NEX) were used considering the limitation in total scan time. The optimal NEX combination for tumor and normal tissue for prostate peripheral region was 1: 9. Also, the minimum percentage accuracy and percentage precision were obtained when low b-value is 0 and high b-value is 800 mm2/s for normal tissue and 1400 mm2/s for tumor tissue. Results also showed that for tissues with 1 x 10-3 < ADC < 2.1 x 10-3 mm 2/s the parameter combination at SNR = 20, b-value pair 0, 800 mm 2/s with NEX = 1:9 can calculate ADC with a percentage accuracy of less than 2% and percentage precision of 6-8%. Also, for tissues with 0.6 x 10-3 < ADC < 1.25 x 10-3 mm2 /s the parameter combination at SNR = 20, b-value pair 0, 1400 mm 2/s with NEX =1:9 can calculate ADC with a percentage accuracy of less than 2% and percentage precision of 6-8%.
Scurr, E D; Collins, D J; Temple, L; Karanjia, N; Leach, M O; Koh, D-M
2012-03-01
To describe the appearances of colorectal liver metastases on diffusion-weighted MRI (DW-MRI) and to compare these appearances with histopathology. 43 patients with colorectal liver metastases were evaluated using breath-hold DW-MRI (b-values 0, 150 and 500 s mm(-2)). The b=500 s mm(-2) DW-MRI were reviewed consensually for lesion size and appearance by two readers. 18/43 patients underwent surgery allowing radiological-pathological comparison. Tissue sections were reviewed by a pathologist, who classified metastases histologically as cellular, fibrotic, necrotic or mixed. The frequency of DW-MRI findings and histological features were compared using the χ(2) test. 84 metastases were found in 43 patients. On b=500 s mm(-2) DW-MRI, metastases showed three high signal intensity patterns: rim (55/84), uniform (23/84) and variegate (6/84). Of the 55 metastases showing rim pattern, 54 were >1 cm in diameter (p<0.01, χ(2) test). 25/84 metastases were surgically resected. Of these, 11/22 metastases >1 cm in diameter showed rim pattern and demonstrated central necrosis at histopathology (p=0.04, χ(2) test). No definite relationship was found between uniform and variegate patterns with histology. Rim high signal intensity was the most common appearance of colorectal liver metastases >1 cm diameter on DW-MRI at b-values of 500 s mm(-2), a finding attributable to central necrosis.
Analysis of Multiple B-Value Diffusion-Weighted Imaging in Pediatric Acute Encephalopathy
Tachibana, Yasuhiko; Aida, Noriko; Niwa, Tetsu; Nozawa, Kumiko; Kusagiri, Kouki; Mori, Kana; Endo, Kazuo; Obata, Takayuki; Inoue, Tomio
2013-01-01
Acute encephalopathy is a disease group more commonly seen in children. It is often severe and has neurological sequelae. Imaging is important for early diagnosis and prompt treatment to ameliorate an unfavorable outcome, but insufficient sensitivity/specificity is a problem. To overcome this, a new value (fraction of high b-pair (FH)) that could be processed from clinically acceptable MR diffusion-weighted imaging (DWI) with three different b-values was designed on the basis of a two-compartment model of water diffusion signal attenuation. The purpose of this study is to compare FH with the apparent diffusion coefficient (ADC) regarding the detectability of pediatric acute encephalopathy. We retrospectively compared the clinical DWI of 15 children (1–10 years old, mean 2.34, 8 boys, 7 girls) of acute encephalopathy with another 16 children (1–11 years old, mean 4.89, 9 boys, 7 girls) as control. A comparison was first made visually by mapping FH on the brain images, and then a second comparison was made on the basis of 10 regions of interest (ROIs) set on cortical and subcortical areas of each child. FH map visually revealed diffusely elevated FH in cortical and subcortical areas of the patients with acute encephalopathy; the changes seemed more diffuse in FH compared to DWI. The comparison based on ROI revealed elevated mean FH in the cortical and subcortical areas of the acute encephalopathy patients compared to control with significant difference (P<0.05). Similar findings were observed even in regions where the findings of DWI were slight. The reduction of mean ADC was significant in regions with severe findings in DWI, but it was not constant in the areas with slighter DWI findings. The detectability of slight changes of cortical and subcortical lesions in acute encephalopathy may be superior in FH compared to ADC. PMID:23755112
Doblas, Sabrina; Wagner, Mathilde; Leitao, Helena S; Daire, Jean-Luc; Sinkus, Ralph; Vilgrain, Valérie; Van Beers, Bernard E
2013-10-01
The objective of this study was to compare the value of the apparent diffusion coefficient (ADC) determined with 3 b values and the intravoxel incoherent motion (IVIM)-derived parameters in the determination of malignancy and characterization of hepatic tumor type. Seventy-six patients with 86 solid hepatic lesions, including 8 hemangiomas, 20 lesions of focal nodular hyperplasia, 9 adenomas, 30 hepatocellular carcinomas, 13 metastases, and 6 cholangiocarcinomas, were assessed in this prospective study. Diffusion-weighted images were acquired with 11 b values to measure the ADCs (with b = 0, 150, and 500 s/mm) and the IVIM-derived parameters, namely, the pure diffusion coefficient and the perfusion-related diffusion fraction and coefficient. The diffusion parameters were compared between benign and malignant tumors and between tumor types, and their diagnostic value in identifying tumor malignancy was assessed. The apparent and pure diffusion coefficients were significantly higher in benign than in malignant tumors (benign: 2.32 [0.87] × 10 mm/s and 1.42 [0.37] × 10 mm/s vs malignant: 1.64 [0.51] × 10 mm/s and 1.14 [0.28] × 10 mm/s, respectively; P < 0.0001 and P = 0.0005), whereas the perfusion-related diffusion parameters did not differ significantly between the 2 groups. The apparent and pure diffusion coefficients provided similar accuracy in assessing tumor malignancy (areas under the receiver operating characteristic curve of 0.770 and 0.723, respectively). In the multigroup analysis, the ADC was found to be significantly higher in hemangiomas than in hepatocellular carcinomas, metastases, and cholangiocarcinomas. In the same manner, it was higher in lesions of focal nodular hyperplasia than in metastases and cholangiocarcinomas. However, the pure diffusion coefficient was significantly higher only in hemangiomas versus hepatocellular and cholangiocellular carcinomas. Compared with the ADC, the diffusion parameters derived from the IVIM model did not improve the determination of malignancy and characterization of hepatic tumor type.
Yin, Jianzhong; Sun, Haizhen; Wang, Zhiyun; Ni, Hongyan; Shen, Wen; Sun, Phillip Zhe
2018-05-01
Purpose To determine the relationship between diffusion-weighted imaging (DWI) and diffusion kurtosis imaging (DKI) in patients with acute stroke at admission and the tissue outcome 1 month after onset of stroke. Materials and Methods Patients with stroke underwent DWI (b values = 0, 1000 sec/mm 2 along three directions) and DKI (b values = 0, 1000, 2000 sec/mm 2 along 20 directions) within 24 hours after symptom onset and 1 month after symptom onset. For large lesions (diameter ≥ 1 cm), acute lesion volumes at DWI and DKI were compared with those at follow-up T2-weighted imaging by using Spearman correlation analysis. For small lesions (diameter < 1 cm), the number of acute lesions at DWI and DKI and follow-up T2-weighted imaging was counted and compared by using the McNemar test. Results Thirty-seven patients (mean age, 58 years; range, 35-82 years) were included. There were 32 large lesions and 138 small lesions. For large lesions, the volumes of acute lesions on kurtosis maps showed no difference from those on 1-month follow-up T2-weighted images (P = .532), with a higher correlation coefficient than those on the apparent diffusion coefficient and mean diffusivity maps (R 2 = 0.730 vs 0.479 and 0.429). For small lesions, the number of acute lesions on DKI, but not on DWI, images was consistent with that on the follow-up T2-weighted images (P = .125). Conclusion DKI complements DWI for improved prediction of outcome of acute ischemic stroke. © RSNA, 2018.
Diffusion Tensor Magnetic Resonance Imaging of the Pancreas
Nissan, Noam; Golan, Talia; Furman-Haran, Edna; Apter, Sara; Inbar, Yael; Ariche, Arie; Bar-Zakay, Barak; Goldes, Yuri; Schvimer, Michael; Grobgeld, Dov; Degani, Hadassa
2014-01-01
Purpose To develop a diffusion-tensor-imaging (DTI) protocol that is sensitive to the complex diffusion and perfusion properties of the healthy and malignant pancreas tissues. Materials and Methods Twenty-eight healthy volunteers and nine patients with pancreatic-ductal-adenocacinoma (PDAC), were scanned at 3T with T2-weighted and DTI sequences. Healthy volunteers were also scanned with multi-b diffusion-weighted-imaging (DWI), whereas a standard clinical protocol complemented the PDAC patients’ scans. Image processing at pixel resolution yielded parametric maps of three directional diffusion coefficients λ1, λ2, λ3, apparent diffusion coefficient (ADC), and fractional anisotropy (FA), as well as a λ1-vector map, and a main diffusion-direction map. Results DTI measurements of healthy pancreatic tissue at b-values 0,500 s/mm2yielded: λ1 = (2.65±0.35)×10−3, λ2 = (1.87±0.22)×10−3, λ3 = (1.20±0.18)×10−3, ADC = (1.91±0.22)×10−3 (all in mm2/s units) and FA = 0.38±0.06. Using b-values of 100,500 s/mm2 led to a significant reduction in λ1, λ2, λ3 and ADC (p<.0001) and a significant increase (p<0.0001) in FA. The reduction in the diffusion coefficients suggested a contribution of a fast intra-voxel-incoherent-motion (IVIM) component at b≤100 s/mm2, which was confirmed by the multi-b DWI results. In PDACs, λ1, λ2, λ3 and ADC in both 0,500 s/mm2 and 100,500 s/mm2 b-values sets, as well as the reduction in these diffusion coefficients between the two sets, were significantly lower in comparison to the distal normal pancreatic tissue, suggesting higher cellularity and diminution of the fast-IVIM component in the cancer tissue. Conclusion DTI using two reference b-values 0 and 100 s/mm2 enabled characterization of the water diffusion and anisotropy of the healthy pancreas, taking into account a contribution of IVIM. The reduction in the diffusion coefficients of PDAC, as compared to normal pancreatic tissue, and the smaller change in these coefficients in PDAC when the reference b-value was modified from 0 to 100 s/mm2, helped identifying the presence of malignancy. PMID:25549366
Feng, Zhaoyan; Min, Xiangde; Margolis, Daniel J. A.; Duan, Caohui; Chen, Yuping; Sah, Vivek Kumar; Chaudhary, Nabin; Li, Basen; Ke, Zan; Zhang, Peipei; Wang, Liang
2017-01-01
Objectives To evaluate the diagnostic performance of different mathematical models and different b-value ranges of diffusion-weighted imaging (DWI) in peripheral zone prostate cancer (PZ PCa) detection. Methods Fifty-six patients with histologically proven PZ PCa who underwent DWI-magnetic resonance imaging (MRI) using 21 b-values (0–4500 s/mm2) were included. The mean signal intensities of the regions of interest (ROIs) placed in benign PZs and cancerous tissues on DWI images were fitted using mono-exponential, bi-exponential, stretched-exponential, and kurtosis models. The b-values were divided into four ranges: 0–1000, 0–2000, 0–3200, and 0–4500 s/mm2, grouped as A, B, C, and D, respectively. ADC,
Diffusion measurements in the ischemic human brain with a steady-state sequence.
Brüning, R; Wu, R H; Deimling, M; Porn, U; Haberl, R L; Reiser, M
1996-11-01
The authors evaluate the clinical usefulness of a diffusion-weighted steady-state free-precession (SSFP) sequence to detect acute and subacute ischemic changes. Twenty-four patients were examined on a 1.5-tesla scanner, using a SSFP-sequence (repetition time [TR]/ echo time [TE] = 22/3-8 mseconds). The slice thickness was 5 mm, 10 averages, 57 seconds per slice. The diffusion gradient strength was 23 millitesla/m, with b-values from 165 to 598 seconds/mm2. Diffusion-weighted images (DWI) were compared with T2-weighted images. The diffusion-weighted SSFP sequence produced diagnostic quality images in 23 of 24 patients. Diffusion depicted (group 1: 0-12 hours) more acute lesions (3 of 6) than T2-weighted images (2 of 6); the mean lesion diameter depicted by diffusion was 10.9 mm (standard deviation [SD], 12.3) and in T2-weighted images was 4.7 mm (SD 6.8). A significant correlation (P < 0.017) in subacute lesions was found when diffusion was compared with turbo spin echo (mean size difference/T2 = 18.5/17.5 mm, SD 13.2/12.2). The diffusion-weighted SSFP-sequence is more sensitive in acute ischemia and delineates likewise in subacute ischemia, when compared with T2-weighted imaging.
Kharuzhyk, S A
2015-01-01
to carry out a quantitative analysis of diffusion-weighted magnetic resonance images (DWI) in cancer of the cervix uteri (CCU) and to estimate the possibility of using pretreatment measured diffusion coefficient (MDC) to predict chemoradiation therapy (CRT). The investigation prospectively enrolled 46 women with morphologically verified Stages IB-IVB CCU. All the women underwent diffusion-weighted magnetic resonance imaging of pelvic organs before and after treatment. A semiautomatic method was used to determine tumor signal intensity (SI) on DWI at b 1000 s/mm2 (SI b1000) and tumor MDC. The reproducibility of MDC measurements was assessed in 16 randomly selected women. The investigators compared the pretreatment quantitative DWI measures in complete and incomplete regression (CR and IR) groups and the presence and absence of tumor progression during a follow-up. An association of MDC with progression-free and overall survivals (PFS and OS) was determined in the patients. A semiautomatic tumor segmentation framework could determine the pretreatment quantitative DMI measures with minimal time spent and high reproducibility. The mean tumor MDC was 0.82 +/- 0.14 x 10(-3) mm2/s. CR and IR were established in 28 and 18 women, respectively. The MDC < or = 0.83 x 10(-3) mm2/s predicted CR with a sensitivity of 64.3% and a specificity of 77.8% (p=0.007). The median follow-up was 47 months (range, 3-82 months). With the MDC < or = 0.86 x 10(-3) mm2/s, 5-year PFS was 74.1% versus 42.1% with a higher MDC (p=0.023) and 5-year OS was 70.4 and 40.6%, respectively (p=0.021). The survival difference was insignificant in relation to the degree of tumor regression. The pretreatment IS at b1000 was of no prognostic value. The pretreatment tumor MDC may serve as a biomarker for predicting the efficiency of CRT for CCU.
Magnetic resonance features of cerebral malaria.
Yadav, P; Sharma, R; Kumar, S; Kumar, U
2008-06-01
Cerebral malaria is a major health hazard, with a high incidence of mortality. The disease is endemic in many developing countries, but with a greater increase in tourism, occasional cases may be detected in countries where the disease in not prevalent. Early diagnosis and evaluation of cerebral involvement in malaria utilizing modern imaging modalities have an impact on the treatment and clinical outcome. To evaluate the magnetic resonance (MR) features of patients with cerebral malaria presenting with altered sensorium. We present the findings in three patients with cerebral malaria presenting with altered sensorium. MR imaging using a 1.5-Tesla unit was carried out. The sequences performed were 5-mm-thick T1-weighted, T2-weighted, fluid-attenuated inversion-recovery (FLAIR), and T2-weighted gradient-echo axial sequences, and sagittal and coronal FLAIR. Diffusion-weighted imaging was performed with b values of 0 and 1000 s/mm(2), and apparent diffusion coefficient (ADC) maps were obtained. Focal hyperintensities in the bilateral periventricular white matter, corpus callosum, occipital subcortex, and bilateral thalami were noticed on T2-weighted and FLAIR sequences. The lesions were more marked in the splenium of the corpus callosum. No enhancement on postcontrast T1-weighted MR images was observed. There was no evidence of restricted diffusion on the diffusion-weighted sequence and ADC map. MR is a sensitive imaging modality, with a role in the assessment of cerebral lesions in malaria. Focal white matter and corpus callosal lesions without any restricted diffusion were the key findings in our patients.
Separation of extra- and intracellular metabolites using hyperpolarized 13C diffusion weighted MR✩
Koelsch, Bertram L.; Sriram, Renuka; Keshari, Kayvan R.; Swisher, Christine Leon; Van Criekinge, Mark; Sukumar, Subramaniam; Vigneron, Daniel B.; Wang, Zhen J.; Larson, Peder E.Z.; Kurhanewicz, John
2017-01-01
This work demonstrates the separation of extra- and intracellular components of glycolytic metabolites with diffusion weighted hyperpolarized 13C magnetic resonance spectroscopy. Using b-values of up to 15,000 s mm−2, a multi-exponential signal response was measured for hyperpolarized [1-13C] pyruvate and lactate. By fitting the fast and slow asymptotes of these curves, their extra- and intracellular weighted diffusion coefficients were determined in cells perfused in a MR compatible bioreactor. In addition to measuring intracellular weighted diffusion, extra- and intracellular weighted hyperpolarized 13C metabolites pools are assessed in real-time, including their modulation with inhibition of monocarboxylate transporters. These studies demonstrate the ability to simultaneously assess membrane transport in addition to enzymatic activity with the use of diffusion weighted hyperpolarized 13C MR. This technique could be an indispensible tool to evaluate the impact of microenvironment on the presence, aggressiveness and metastatic potential of a variety of cancers. PMID:27434780
Suárez, Inmaculada; Coto, Baudilio
2015-08-14
Average molecular weights and polydispersity indexes are some of the most important parameters considered in the polymer characterization. Usually, gel permeation chromatography (GPC) and multi angle light scattering (MALS) are used for this determination, but GPC values are overestimated due to the dispersion introduced by the column separation. Several procedures were proposed to correct such effect usually involving more complex calibration processes. In this work, a new method of calculation has been considered including diffusion effects. An equation for the concentration profile due to diffusion effects along the GPC column was considered to be a Fickian function and polystyrene narrow standards were used to determine effective diffusion coefficients. The molecular weight distribution function of mono and poly disperse polymers was interpreted as a sum of several Fickian functions representing a sample formed by only few kind of polymer chains with specific molecular weight and diffusion coefficient. Proposed model accurately fit the concentration profile along the whole elution time range as checked by the computed standard deviation. Molecular weights obtained by this new method are similar to those obtained by MALS or traditional GPC while polydispersity index values are intermediate between those obtained by the traditional GPC combined to Universal Calibration method and the MALS method. Values for Pearson and Lin coefficients shows improvement in the correlation of polydispersity index values determined by GPC and MALS methods when diffusion coefficients and new methods are used. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhou, Mei-Ling; Yan, Fu-Hua; Xu, Peng-Ju; Chen, Cai-Zhong; Shen, Ji-Zhang; Li, Ren-Chen; Ji, Yuan; Shi, Jian-Ying
2009-07-07
To evaluate the clinical practical value of apparent diffusion coefficient (ADC) measurements based on diffusion-weighted MR imaging (DWI) for quantification of liver fibrosis and inflammation for hepatitis viral infection. Diffusion-weighted MRI with parallel imaging was prospectively performed on 85 patients with chronic hepatitis and on 22 healthy volunteers within a single breath-hold using a single-shot spin-echo echo-planar sequence at b values of 100, 300, 500, 800 and 1000 s/mm2 respectively. ADC values of liver were measured with five different b values. The inflammation grades and fibrosis stages were evaluated histologically by biopsy. One-way analysis of variance and Spearman' s rank correlation test were used for statistical analysis. Receiver operating characteristics analysis was used to assess the performance of ADC in predicting the presence of stage > or = 2 and stage > or = 3 hepatic fibrosis, and grade > or = 1 hepatic inflammation. There was moderate negative correlation between hepatic ADC values and fibrosis stage. And the best correlation was obtained for a b value of 800 s/mm2 (r = -0.697, P = 0. 000). At all b values there was a significant decrease in hepatic ADC in patients with stage < or = 1 versus stage > or = 2 fibrosis and stage < or = 2 versus stage > or = 3 fibrosis (P < 0.05). Hepatic ADC was a significant predictor of stage > or = 2 and > or = 3 fibrosis. The areas under the curve were 0.909 vs 0.917, sensitivity 76.6% vs 80.0% and specificity 88.3% vs 91.5% (ADC with a b value of 800 s/mm2, 1.26 x 10(-3) mm2/s or less and 1.19 x 10(-3) mm2/s or less). There was weak to moderate negative correlation between ADCs and inflammation grade. Hepatic ADC was a significant predictor of grade > 1 inflammation with an area under the curve of 0.781, sensitivity of 60.0% and specificity of 86.4% (ADC with a b value of 500 s/mm2, 1.54 x 10(-3) mm2/s or less). The DWI measurement of hepatic ADC can be used to quantify liver fibrosis and inflammation. It will be a new approach for early diagnosis and therapeutic follow-up of hepatic fibrosis.
Lanzafame, S; Giannelli, M; Garaci, F; Floris, R; Duggento, A; Guerrisi, M; Toschi, N
2016-05-01
An increasing number of studies have aimed to compare diffusion tensor imaging (DTI)-related parameters [e.g., mean diffusivity (MD), fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD)] to complementary new indexes [e.g., mean kurtosis (MK)/radial kurtosis (RK)/axial kurtosis (AK)] derived through diffusion kurtosis imaging (DKI) in terms of their discriminative potential about tissue disease-related microstructural alterations. Given that the DTI and DKI models provide conceptually and quantitatively different estimates of the diffusion tensor, which can also depend on fitting routine, the aim of this study was to investigate model- and algorithm-dependent differences in MD/FA/RD/AD and anisotropy mode (MO) estimates in diffusion-weighted imaging of human brain white matter. The authors employed (a) data collected from 33 healthy subjects (20-59 yr, F: 15, M: 18) within the Human Connectome Project (HCP) on a customized 3 T scanner, and (b) data from 34 healthy subjects (26-61 yr, F: 5, M: 29) acquired on a clinical 3 T scanner. The DTI model was fitted to b-value =0 and b-value =1000 s/mm(2) data while the DKI model was fitted to data comprising b-value =0, 1000 and 3000/2500 s/mm(2) [for dataset (a)/(b), respectively] through nonlinear and weighted linear least squares algorithms. In addition to MK/RK/AK maps, MD/FA/MO/RD/AD maps were estimated from both models and both algorithms. Using tract-based spatial statistics, the authors tested the null hypothesis of zero difference between the two MD/FA/MO/RD/AD estimates in brain white matter for both datasets and both algorithms. DKI-derived MD/FA/RD/AD and MO estimates were significantly higher and lower, respectively, than corresponding DTI-derived estimates. All voxelwise differences extended over most of the white matter skeleton. Fractional differences between the two estimates [(DKI - DTI)/DTI] of most invariants were seen to vary with the invariant value itself as well as with MK/RK/AK values, indicating substantial anatomical variability of these discrepancies. In the HCP dataset, the median voxelwise percentage differences across the whole white matter skeleton were (nonlinear least squares algorithm) 14.5% (8.2%-23.1%) for MD, 4.3% (1.4%-17.3%) for FA, -5.2% (-48.7% to -0.8%) for MO, 12.5% (6.4%-21.2%) for RD, and 16.1% (9.9%-25.6%) for AD (all ranges computed as 0.01 and 0.99 quantiles). All differences/trends were consistent between the discovery (HCP) and replication (local) datasets and between estimation algorithms. However, the relationships between such trends, estimated diffusion tensor invariants, and kurtosis estimates were impacted by the choice of fitting routine. Model-dependent differences in the estimation of conventional indexes of MD/FA/MO/RD/AD can be well beyond commonly seen disease-related alterations. While estimating diffusion tensor-derived indexes using the DKI model may be advantageous in terms of mitigating b-value dependence of diffusivity estimates, such estimates should not be referred to as conventional DTI-derived indexes in order to avoid confusion in interpretation as well as multicenter comparisons. In order to assess the potential and advantages of DKI with respect to DTI as well as to standardize diffusion-weighted imaging methods between centers, both conventional DTI-derived indexes and diffusion tensor invariants derived by fitting the non-Gaussian DKI model should be separately estimated and analyzed using the same combination of fitting routines.
Fan, Qiuyun; Nummenmaa, Aapo; Witzel, Thomas; Zanzonico, Roberta; Keil, Boris; Cauley, Stephen; Polimeni, Jonathan R; Tisdall, Dylan; Van Dijk, Koene R A; Buckner, Randy L; Wedeen, Van J; Rosen, Bruce R; Wald, Lawrence L
2014-11-01
One of the major goals of the NIH Blueprint Human Connectome Project was to map and quantify the white matter connections in the brain using diffusion tractography. Given the prevalence of complex white matter structures, the capability of resolving local white matter geometries with multiple crossings in the diffusion magnetic resonance imaging (dMRI) data is critical. Increasing b-value has been suggested for delineation of the finer details of the orientation distribution function (ODF). Although increased gradient strength and duration increase sensitivity to highly restricted intra-axonal water, gradient strength limitations require longer echo times (TE) to accommodate the increased diffusion encoding times needed to achieve a higher b-value, exponentially lowering the signal-to-noise ratio of the acquisition. To mitigate this effect, the MGH-USC Connectom scanner was built with 300 mT/m gradients, which can significantly reduce the TE of high b-value diffusion imaging. Here we report comparisons performed across b-values based on q-ball ODF metrics to investigate whether high b-value diffusion imaging on the Connectom scanner can improve resolving complex white matter structures. The q-ball ODF features became sharper as the b-value increased, with increased power fraction in higher order spherical harmonic series of the ODF and increased peak heights relative to the overall size of the ODF. Crossing structures were detected in an increasingly larger fraction of white matter voxels and the spatial distribution of two-way and three-way crossing structures was largely consistent with known anatomy. Results indicate that dMRI with high diffusion encoding on the Connectom system is a promising tool to better characterize, and ultimately understand, the underlying structural organization and motifs in the human brain.
Soyer, Philippe; Lagadec, Matthieu; Sirol, Marc; Dray, Xavier; Duchat, Florent; Vignaud, Alexandre; Fargeaudou, Yann; Placé, Vinciane; Gault, Valérie; Hamzi, Lounis; Pocard, Marc; Boudiaf, Mourad
2010-02-11
Our objective was to determine the diagnostic accuracy of a free-breathing diffusion-weighted single-shot echo-planar magnetic resonance imaging (FBDW-SSEPI) technique with parallel imaging and high diffusion factor value (b = 1000 s/mm2) in the detection of primary rectal adenocarcinomas. Thirty-one patients (14M and 17F; mean age 67 years) with histopathologically proven primary rectal adenocarcinomas and 31 patients without rectal malignancies (14M and 17F; mean age 63.6 years) were examined with FBDW-SSEPI (repetition time (TR/echo time (TE) 3900/91 ms, gradient strength 45 mT/m, acquisition time 2 min) at 1.5 T using generalized autocalibrating partially parallel acquisitions (GRAPPA, acceleration factor 2) and a b value of 1000 s/mm2. Apparent diffusion coefficients (ADCs) of rectal adenocarcinomas and normal rectal wall were measured. FBDW-SSEPI images were evaluated for tumour detection by 2 readers. Sensitivity, specificity, accuracy and Youden score for rectal adenocarcinoma detection were calculated with their 95% confidence intervals (CI) for ADC value measurement and visual image analysis. Rectal adenocarcinomas had significantly lower ADCs (mean 1.036 x 10(-3)+/- 0.107 x 10(-3) mm2/s; median 1.015 x 10(-3) mm2/s; range (0.827-1.239) x 10(-3) mm2/s) compared with the rectal wall of control subjects (mean 1.387 x 10(-3)+/- 0.106 x 10(-3) mm2/s; median 1.385 x 10(-3) mm2/s; range (1.176-1.612) x 10(-3) mm2/s) (p < 0.0001). Using a threshold value < or = 1.240 x 10(-3) mm2/s, all rectal adenocarcinomas were correctly categorized and 100% sensitivity (31/31; 95% CI 95-100%), 94% specificity (31/33; 95% CI 88-100%), 97% accuracy (60/62; 95% CI 92-100%) and Youden index 0.94 were obtained for the diagnosis of rectal adenocarcinoma. FBDW-SSEPI image analysis allowed depiction of all rectal adenocarcinomas but resulted in 2 false-positive findings, yielding 100% sensitivity (31/31; 95% CI 95-100%), 94% specificity (31/33; 95% CI 88-100%), 97% accuracy (60/62; 95% CI 92-100%) and Youden index 0.94 for the diagnosis of primary rectal adenocarcinoma. We can conclude that FBDW-SSEPI using parallel imaging and high b value may be helpful in the detection of primary rectal adenocarcinomas.
NASA Astrophysics Data System (ADS)
Nath, Vishwesh; Schilling, Kurt G.; Blaber, Justin A.; Ding, Zhaohua; Anderson, Adam W.; Landman, Bennett A.
2017-02-01
Crossing fibers are prevalent in human brains and a subject of intense interest for neuroscience. Diffusion tensor imaging (DTI) can resolve tissue orientation but is blind to crossing fibers. Many advanced diffusion-weighted magnetic resolution imaging (MRI) approaches have been presented to extract crossing-fibers from high angular resolution diffusion imaging (HARDI), but the relative sensitivity and specificity of approaches remains unclear. Here, we examine two leading approaches (PAS and q-ball) in the context of a large-scale, single subject reproducibility study. A single healthy individual was scanned 11 times with 96 diffusion weighted directions and 10 reference volumes for each of five b-values (1000, 1500, 2000, 2500, 3000 s/mm2) for a total of 5830 volumes (over the course of three sessions). We examined the reproducibility of the number of fibers per voxel, volume fraction, and crossing-fiber angles. For each method, we determined the minimum resolvable angle for each acquisition. Reproducibility of fiber counts per voxel was generally high ( 80% consensus for PAS and 70% for q-ball), but there was substantial bias between individual repetitions and model estimated with all data ( 10% lower consensus for PAS and 15% lower for q-ball). Both PAS and q-ball predominantly discovered fibers crossing at near 90 degrees, but reproducibility was higher for PAS across most measures. Within voxels with low anisotropy, q-ball finds more intra-voxel structure; meanwhile, PAS resolves multiple fibers at greater than 75 degrees for more voxels. These results can inform researchers when deciding between HARDI approaches or interpreting findings across studies.
Yuan, Jing; Yeung, David Ka Wai; Mok, Greta S. P.; Bhatia, Kunwar S.; Wang, Yi-Xiang J.; Ahuja, Anil T.; King, Ann D.
2014-01-01
Purpose To technically investigate the non-Gaussian diffusion of head and neck diffusion weighted imaging (DWI) at 3 Tesla and compare advanced non-Gaussian diffusion models, including diffusion kurtosis imaging (DKI), stretched-exponential model (SEM), intravoxel incoherent motion (IVIM) and statistical model in the patients with nasopharyngeal carcinoma (NPC). Materials and Methods After ethics approval was granted, 16 patients with NPC were examined using DWI performed at 3T employing an extended b-value range from 0 to 1500 s/mm2. DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models on primary tumor, metastatic node, spinal cord and muscle. Non-Gaussian parameter maps were generated and compared to apparent diffusion coefficient (ADC) maps in NPC. Results Diffusion in NPC exhibited non-Gaussian behavior at the extended b-value range. Non-Gaussian models achieved significantly better fitting of DWI signal than the mono-exponential model. Non-Gaussian diffusion coefficients were substantially different from mono-exponential ADC both in magnitude and histogram distribution. Conclusion Non-Gaussian diffusivity in head and neck tissues and NPC lesions could be assessed by using non-Gaussian diffusion models. Non-Gaussian DWI analysis may reveal additional tissue properties beyond ADC and holds potentials to be used as a complementary tool for NPC characterization. PMID:24466318
Williams, Rebecca J; Reutens, David C; Hocking, Julia
2015-11-01
Decreased water displacement following increased neural activity has been observed using diffusion-weighted functional MRI (DfMRI) at high b-values. The physiological mechanisms underlying the diffusion signal change may be unique from the standard blood oxygenation level-dependent (BOLD) contrast and closer to the source of neural activity. Whether DfMRI reflects neural activity more directly than BOLD outside the primary cerebral regions remains unclear. Colored and achromatic Mondrian visual stimuli were statistically contrasted to functionally localize the human color center Area V4 in neurologically intact adults. Spatial and temporal properties of DfMRI and BOLD activation were examined across regions of the visual cortex. At the individual level, DfMRI activation patterns showed greater spatial specificity to V4 than BOLD. The BOLD activation patterns were more prominent in the primary visual cortex than DfMRI, where activation was localized to the ventral temporal lobe. Temporally, the diffusion signal change in V4 and V1 both preceded the corresponding hemodynamic response, however the early diffusion signal change was more evident in V1. DfMRI may be of use in imaging applications implementing cognitive subtraction paradigms, and where highly precise individual functional localization is required.
Diffusion-weighted MR imaging findings of kidneys in patients with early phase of obstruction.
Bozgeyik, Zulkif; Kocakoc, Ercan; Sonmezgoz, Fitnet
2009-04-01
Diffusion-weighted (DW) magnetic resonance (MR) imaging is an MR technique used to show molecular diffusion. The apparent diffusion coefficient (ADC), as a quantitative parameter calculated from the DW MR images. The purpose of this study is to evaluate the ability of DW MR imaging in early phase of obstruction due to urolithiasis. Twenty-six patients with acute dilatation of the pelvicalyceal system detected by intravenous urography were included in this study. MR imaging was performed using a 1.5 T whole-body superconducting MR scanner. DW imaging can be performed using single-shot spin-echo, echo-planar imaging (EPI) sequences with the following diffusion gradient b values: 100, 600, 1000 s/mm(2). Circular region of interest (ROI) was placed in the renal parenchyma for the measurement of ADC values in the normal and obstructed kidney. For statistical analyses, Paired t test were used. In spite of obstructed kidneys had the lower ADC values compared to normal kidneys, these alterations were statistically insignificant. We did not observe significantly different ADC values of early phase of obstructed kidneys compared to normal kidneys.
Sapkota, Nabraj; Shi, Xianfeng; Shah, Lubdha M; Bisson, Erica F; Rose, John W; Jeong, Eun-Kee
2017-06-01
High-resolution diffusion-weighted imaging (DWI) of the spinal cord (SC) is problematic because of the small cross-section of the SC and the large field inhomogeneity. Obtaining the ultrahigh-b DWI poses a further challenge. The purpose of the study was to design and validate two-dimensional (2D) single-shot diffusion-weighted stimulated echo planar imaging with reduced field of view (2D ss-DWSTEPI-rFOV) for ultrahigh-b radial DWI (UHB-rDWI) of the SC. A novel time-efficient 2D ss-DWSTEPI-rFOV sequence was developed based on the stimulated echo sequence. Reduced-phase field of view was obtained by using two slice-selective 90 ° radiofrequency pulses in the presence of the orthogonal slice selection gradients. The sequence was validated on a cylindrical phantom and demonstrated on SC imaging. Ultrahigh-b radial diffusion-weighted ( bmax = 7300 s/mm2) images of the SC with greatly reduced distortion were obtained. The exponential plus constant fitting of the diffusion-decay curve estimated the constant fraction (restricted water fraction) as 0.36 ± 0.05 in the SC white matter. A novel 2D ss-DWSTEPI-rFOV sequence has been designed and demonstrated for high-resolution UHB-rDWI of localized anatomic structures with significantly reduced distortion induced by nonlinear static field inhomogeneity. Magn Reson Med 77:2167-2173, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Bourne, Roger; Liang, Sisi; Panagiotaki, Eleftheria; Bongers, Andre; Sved, Paul; Watson, Geoffrey
2017-10-01
The purpose of this study was to measure and model the diffusion time dependence of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) derived from conventional prostate diffusion-weighted imaging methods as used in recommended multiparametric MRI protocols. Diffusion tensor imaging (DTI) was performed at 9.4 T with three radical prostatectomy specimens, with diffusion times in the range 10-120 ms and b-values 0-3000 s/mm 2 . ADC and FA were calculated from DTI measurements at b-values of 800 and 1600 s/mm 2 . Independently, a two-component model (restricted isotropic plus Gaussian anisotropic) was used to synthesize DTI data, from which ADC and FA were predicted and compared with the measured values. Measured ADC and FA exhibited a diffusion time dependence, which was closely predicted by the two-component model. ADC decreased by about 0.10-0.15 μm 2 /ms as diffusion time increased from 10 to 120 ms. FA increased with diffusion time at b-values of 800 and 1600 s/mm 2 but was predicted to be independent of diffusion time at b = 3000 s/mm 2 . Both ADC and FA exhibited diffusion time dependence that could be modeled as two unmixed water pools - one having isotropic restricted dynamics, and the other unrestricted anisotropic dynamics. These results highlight the importance of considering and reporting diffusion times in conventional ADC and FA calculations and protocol recommendations, and inform the development of improved diffusion methods for prostate cancer imaging. Copyright © 2017 John Wiley & Sons, Ltd.
Assessment of mediastinal tumors with diffusion-weighted single-shot echo-planar MRI.
Razek, Ahmed Abdel; Elmorsy, Ahmed; Elshafey, Mohsen; Elhadedy, Tamer; Hamza, Osama
2009-09-01
To assess the role of diffusion-weighted single-shot echo-planar magnetic resonance imaging (MRI) in patients with mediastinal tumors. Prospective study was conducted on 45 consecutive patients (29 male, 16 female, age 22-66 years, mean 41 years) with mediastinal tumor. They underwent diffusion-weighted single-shot echo-planar MRI of the mediastinum with a b-factor of 0, 300, and 600 sec/mm(2). The apparent diffusion coefficient (ADC) value of the mediastinal tumor was correlated with the histopathological findings. The mean ADC value of malignant mediastinal tumors was 1.09 +/- 0.25 x 10(-3) mm(2)/sec, and of benign tumors was 2.38 +/- 0.56 x 10(-3) mm(2)/sec. There was a significant difference in the mean ADC value between malignant and benign tumors (P = 0.001) and within different grades of malignancy (0.001). When an ADC value of 1.56 x 10(-3) mm(2)/sec was used as a threshold value for differentiating malignant from benign tumor, the best results were obtained with an accuracy of 95%, sensitivity of 96%, specificity of 94%, positive predictive value of 94%, negative predictive value of 96%, and area under the curve of 0.938. The ADC value is a noninvasive parameter that can be used for differentiation of malignant from benign mediastinal tumors and grading of mediastinal malignancy.
Ha, Hong Il; Kim, Ah Young; Yu, Chang Sik; Park, Seong Ho; Ha, Hyun Kwon
2013-12-01
To evaluate DW MR tumour volumetry and post-CRT ADC in rectal cancer as predicting factors of CR using high b values to eliminate perfusion effects. One hundred rectal cancer patients who underwent 1.5-T rectal MR and DW imaging using three b factors (0, 150, and 1,000 s/mm(2)) were enrolled. The tumour volumes of T2-weighted MR and DW images and pre- and post-CRT ADC150-1000 were measured. The diagnostic accuracy of post-CRT ADC, T2-weighted MR, and DW tumour volumetry was compared using ROC analysis. DW MR tumour volumetry was superior to T2-weighted MR volumetry comparing the CR and non-CR groups (P < 0.001). Post-CRT ADC showed a significant difference between the CR and non-CR groups (P = 0.001). The accuracy of DW tumour volumetry (Az = 0.910) was superior to that of T2-weighed MR tumour volumetry (Az = 0.792) and post-CRT ADC (Az = 0.705) in determining CR (P = 0.015). Using a cutoff value for the tumour volume reduction rate of more than 86.8 % on DW MR images, the sensitivity and specificity for predicting CR were 91.4 % and 80 %, respectively. DW MR tumour volumetry after CRT showed significant superiority in predicting CR compared with T2-weighted MR images and post-CRT ADC.
Scurr, E D; Collins, D J; Temple, L; Karanjia, N; Leach, M O; Koh, D-M
2012-01-01
Objective To describe the appearances of colorectal liver metastases on diffusion-weighted MRI (DW-MRI) and to compare these appearances with histopathology. Methods 43 patients with colorectal liver metastases were evaluated using breath-hold DW-MRI (b-values 0, 150 and 500 s mm–2). The b=500 s mm–2 DW-MRI were reviewed consensually for lesion size and appearance by two readers. 18/43 patients underwent surgery allowing radiological–pathological comparison. Tissue sections were reviewed by a pathologist, who classified metastases histologically as cellular, fibrotic, necrotic or mixed. The frequency of DW-MRI findings and histological features were compared using the χ2 test. Results 84 metastases were found in 43 patients. On b=500 s mm–2 DW-MRI, metastases showed three high signal intensity patterns: rim (55/84), uniform (23/84) and variegate (6/84). Of the 55 metastases showing rim pattern, 54 were >1 cm in diameter (p<0.01, χ2 test). 25/84 metastases were surgically resected. Of these, 11/22 metastases >1 cm in diameter showed rim pattern and demonstrated central necrosis at histopathology (p=0.04, χ2 test). No definite relationship was found between uniform and variegate patterns with histology. Conclusion Rim high signal intensity was the most common appearance of colorectal liver metastases >1 cm diameter on DW-MRI at b-values of 500 s mm–2, a finding attributable to central necrosis. PMID:21224302
Kleinnijenhuis, Michiel; Mollink, Jeroen; Lam, Wilfred W; Kinchesh, Paul; Khrapitchev, Alexandre A; Smart, Sean C; Jbabdi, Saad; Miller, Karla L
2018-02-01
To demonstrate how reference data affect the quantification of the apparent diffusion coefficient (ADC) in long diffusion time measurements with diffusion-weighted stimulated echo acquisition mode (DW-STEAM) measurements, and to present a modification to avoid contribution from crusher gradients in DW-STEAM. For DW-STEAM, reference measurements at long diffusion times have significant b 0 value, because b = 0 cannot be achieved in practice as a result of the need for signal spoiling. Two strategies for acquiring reference data over a range of diffusion times were considered: constant diffusion weighting (fixed-b 0 ) and constant gradient area (fixed-q 0 ). Fixed-b 0 and fixed-q 0 were compared using signal calculations for systems with one and two diffusion coefficients, and experimentally using data from postmortem human corpus callosum samples. Calculations of biexponential diffusion decay show that the ADC is underestimated for reference images with b > 0, which can induce an apparent time-dependence for fixed-q 0 . Restricted systems were also found to be affected. Experimentally, the exaggeration of the diffusion time-dependent effect under fixed-q 0 versus fixed-b 0 was in a range predicted theoretically, accounting for 62% (longitudinal) and 35% (radial) of the time dependence observed in white matter. Variation in the b-value of reference measurements in DW-STEAM can induce artificial diffusion time dependence in ADC, even in the absence of restriction. Magn Reson Med 79:952-959, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Rapacchi, Stanislas; Wen, Han; Viallon, Magalie; Grenier, Denis; Kellman, Peter; Croisille, Pierre; Pai, Vinay M
2011-12-01
Diffusion-weighted imaging (DWI) using low b-values permits imaging of intravoxel incoherent motion in tissues. However, low b-value DWI of the human heart has been considered too challenging because of additional signal loss due to physiological motion, which reduces both signal intensity and the signal-to-noise ratio (SNR). We address these signal loss concerns by analyzing cardiac motion during a heartbeat to determine the time-window during which cardiac bulk motion is minimal. Using this information to optimize the acquisition of DWI data and combining it with a dedicated image processing approach has enabled us to develop a novel low b-value diffusion-weighted cardiac magnetic resonance imaging approach, which significantly reduces intravoxel incoherent motion measurement bias introduced by motion. Simulations from displacement encoded motion data sets permitted the delineation of an optimal time-window with minimal cardiac motion. A number of single-shot repetitions of low b-value DWI cardiac magnetic resonance imaging data were acquired during this time-window under free-breathing conditions with bulk physiological motion corrected for by using nonrigid registration. Principal component analysis (PCA) was performed on the registered images to improve the SNR, and temporal maximum intensity projection (TMIP) was applied to recover signal intensity from time-fluctuant motion-induced signal loss. This PCATMIP method was validated with experimental data, and its benefits were evaluated in volunteers before being applied to patients. Optimal time-window cardiac DWI in combination with PCATMIP postprocessing yielded significant benefits for signal recovery, contrast-to-noise ratio, and SNR in the presence of bulk motion for both numerical simulations and human volunteer studies. Analysis of mean apparent diffusion coefficient (ADC) maps showed homogeneous values among volunteers and good reproducibility between free-breathing and breath-hold acquisitions. The PCATMIP DWI approach also indicated its potential utility by detecting ADC variations in acute myocardial infarction patients. Studying cardiac motion may provide an appropriate strategy for minimizing the impact of bulk motion on cardiac DWI. Applying PCATMIP image processing improves low b-value DWI and enables reliable analysis of ADC in the myocardium. The use of a limited number of repetitions in a free-breathing mode also enables easier application in clinical conditions.
Veraart, Jelle; Sijbers, Jan; Sunaert, Stefan; Leemans, Alexander; Jeurissen, Ben
2013-11-01
Linear least squares estimators are widely used in diffusion MRI for the estimation of diffusion parameters. Although adding proper weights is necessary to increase the precision of these linear estimators, there is no consensus on how to practically define them. In this study, the impact of the commonly used weighting strategies on the accuracy and precision of linear diffusion parameter estimators is evaluated and compared with the nonlinear least squares estimation approach. Simulation and real data experiments were done to study the performance of the weighted linear least squares estimators with weights defined by (a) the squares of the respective noisy diffusion-weighted signals; and (b) the squares of the predicted signals, which are reconstructed from a previous estimate of the diffusion model parameters. The negative effect of weighting strategy (a) on the accuracy of the estimator was surprisingly high. Multi-step weighting strategies yield better performance and, in some cases, even outperformed the nonlinear least squares estimator. If proper weighting strategies are applied, the weighted linear least squares approach shows high performance characteristics in terms of accuracy/precision and may even be preferred over nonlinear estimation methods. Copyright © 2013 Elsevier Inc. All rights reserved.
Diffusion-weighted imaging in the evaluation of odontogenic cysts and tumours.
Srinivasan, K; Seith Bhalla, A; Sharma, R; Kumar, A; Roychoudhury, A; Bhutia, O
2012-10-01
The differentiation between keratocystic odontogenic tumour (KCOT) and other cystic/predominantly cystic odontogenic tumours is difficult on conventional CT and MR sequences as there is overlap in the imaging characteristics of these lesions. The purpose of this study was to evaluate the role of diffusion-weighted imaging (DWI) and to assess the performance of apparent diffusion coefficients (ADCs) in the differential diagnosis of odontogenic cysts and tumours. 20 patients with odontogenic cysts and tumours of the maxillomandibular region were examined with DWI. Diffusion-weighted images were obtained with a single-shot echoplanar technique with b-values of 0, 500 and 1000 s mm(-2). An ADC map was obtained at each slice position. The cystic areas of ameloblastoma (n=10) showed free diffusion with a mean ADC value of 2.192±0.33×10(-3) mm(2) s(-1), whereas the solid areas showed restricted diffusion with a mean ADC value of 1.041±0.41×10(-3) mm(2) s(-1). KCOT (n=5) showed restricted diffusion with a mean ADC value of 1.019±0.07×10(-3) mm(2) s(-1). There was a significant difference between the ADC values of KCOT and cystic ameloblastoma (p<0.01, Mann-Whitney U-test). The cut-off with which KCOT and predominantly cystic ameloblastomas were optimally differentiated was 2.013×10(-3) mm(2) s(-1), which yielded 100% sensitivity and 100% specificity. DWI can be used to differentiate KCOT from cystic (or predominantly cystic) odontogenic tumours.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, Nan-Jie; Wong, Chun-Sing, E-mail: drcswong@gmail.com; Chu, Yiu-Ching
2013-10-01
Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using themore » proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.« less
Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis
Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos
2015-01-01
Background Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). Methods 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm2. ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. Results The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm2) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10-3 mm2/s. Conclusion 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD. PMID:25608776
Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis.
Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos
2015-01-01
Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm 2 . ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm 2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm 2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm 2 ) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10 -3 mm 2 /s. 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD.
Chung, Ho Yin; Xu, Xiaopei; Lau, Vince Wing Hang; Ho, Grace; Lee, Ka Lai; Li, Philip Hei; Tsang, Helen Hoi Lun; Kwok, Suet Kei; Lau, Chak Sing; Wong, Chun Sing
2017-01-01
To investigate the usefulness of diffusion weighted imaging (DWI) by comparing with clinical features, blood parameters and traditional short tau inversion recovery (STIR) sequence in detecting spinal and sacroiliac (SI) joint inflammation in axial spondyloarthritis (axSpA) patients. One hundred and ten axSpA patients were recruited. Clinical, radiological and blood parameters were recorded. DWI and STIR MRI were performed simultaneously and results were scored according to the Spondyloarthritis Research Consortium of Canada (SPARCC) for comparison. Apparent diffusion coef cient (ADC) values were also calculated. DWI did not correlate with clinical parameters or blood parameters. It also had lowered sensitivity. When compared with STIR sequence, it correlated well with STIR sequence at the SI joint level (CC 0.76, p<0.001), but weakly at the spinal level (CC 0.23, p=0.02). At the SI joint level, the presence of inflammation on both STIR sequence and DWI was associated with an increase in maximum (B=0.24, p=0.02 in STIR; B=0.37, p<0.001 in DWI) and mean ADC values (B=0.17, p=0.003 in STIR; B=0.15, p=0.01 in DWI). Maximum (B=0.19, p=0.04) and mean spinal ADC values (B=0.18, p=0.01) were also positively associated with DWI detected spinal inflammation. Presence of Modic lesions showed positive correlation with STIR sequence (B=7.12, p=0.01) but not spinal ADC values. Despite DWI correlates with STIR sequence, it has lower sensitivity. However, ADC values appear to be independent of Modic lesions and may supplement STIR sequence to differentiate degeneration.
Gas-diffusion-based passive sampler for ammonia monitoring in marine waters.
O'Connor Šraj, Lenka; Almeida, M Inês G S; Bassett, Chelsea; McKelvie, Ian D; Kolev, Spas D
2018-05-01
A novel passive sampler based on gas-diffusion across a hydrophobic membrane is described for the determination of the time-weighted average concentration of dissolved molecular ammonia in high ionic strength aquatic environments, such as sea, coastal and estuarine waters, for a period of 3 days. The passive sampler developed is cheap, easy-to-use, reusable, and has a dynamic concentration range of 2.0-12µM, which covers the water quality guideline trigger value of 11.4µM (160µgL -1 NH 3 -N) for high conservation value waters, making this a powerful new tool for water quality managers involved in long-term ammonia monitoring. The gas-diffusion-based passive sampler was calibrated under laboratory conditions and deployed in a tank of seawater in the laboratory and at an estuarine site for proof of concept, and a good agreement between passive and spot sampling was achieved in both cases. Copyright © 2017 Elsevier B.V. All rights reserved.
Abdel Razek, Ahmed Abdel Khalek; Khairy, Mohamed; Nada, Nadia
2014-10-01
To assess thymic epithelial tumors with diffusion-weighted magnetic resonance (MR) imaging. Informed consent from patients and institutional review board approval were obtained. Prospective study was conducted on 30 consecutive patients (21 men and nine women; age range, 35-71 years) with thymic epithelial tumors. They underwent true fast imaging with steady-state precession and single-shot echo-planar diffusion-weighted MR imaging of the mediastinum with b values of 0, 400, and 800 sec/mm(2). Apparent diffusion coefficient (ADC) of the thymic epithelial tumors was calculated by the same observer at two settings and was correlated with World Health Organization classification and clinical staging. There was significant difference in longest diameter (P = .001) and necrotic part of the tumor (P = .014) between low-risk thymoma, high-risk thymoma, and thymic carcinoma. Mean ADC value of both readings of thymic epithelial tumors (n = 30) was 1.24 × 10(-3) mm(2)/sec and 1.22 × 10(-3) mm(2)/sec, with good intraobserver agreement (κ = 0.732). There was significant difference in both readings (P = .01 and .20) of low-risk thymoma (1.30 × 10(-3) mm(2)/sec and 1.29 × 10(-3) mm(2)/sec), high-risk thymoma (1.16 × 10(-3) mm(2)/sec and 1.14 × 10(-3) mm(2)/sec), and thymic carcinoma (1.18 × 10(-3) mm(2)/sec and 1.06 × 10(-3) mm(2)/sec). Cutoff ADC values of both readings used to differentiate low-risk thymoma from high-risk thymoma and thymic carcinoma were 1.25 and 1.22 × 10(-3) mm(2)/sec with area under the curve of 0.804 and 0.851, respectively. There was significant difference in both readings of ADC value of early (stage I, II) and advanced stages (stage III, IV) of thymic epithelial tumors (P = .006 and .005, respectively). ADC value is a noninvasive, reliable, and reproducible imaging parameter that may help to assess and characterize thymic epithelial tumors. © RSNA, 2014.
Lee, Dong-Hoon; Lee, Do-Wan; Henry, David; Park, Hae-Jin; Han, Bong-Soo; Woo, Dong-Cheol
2018-04-12
To evaluate the effects of signal intensity differences between the b0 image and diffusion tensor imaging (DTI) in the image registration process. To correct signal intensity differences between the b0 image and DTI data, a simple image intensity compensation (SIMIC) method, which is a b0 image re-calculation process from DTI data, was applied before the image registration. The re-calculated b0 image (b0 ext ) from each diffusion direction was registered to the b0 image acquired through the MR scanning (b0 nd ) with two types of cost functions and their transformation matrices were acquired. These transformation matrices were then used to register the DTI data. For quantifications, the dice similarity coefficient (DSC) values, diffusion scalar matrix, and quantified fibre numbers and lengths were calculated. The combined SIMIC method with two cost functions showed the highest DSC value (0.802 ± 0.007). Regarding diffusion scalar values and numbers and lengths of fibres from the corpus callosum, superior longitudinal fasciculus, and cortico-spinal tract, only using normalised cross correlation (NCC) showed a specific tendency toward lower values in the brain regions. Image-based distortion correction with SIMIC for DTI data would help in image analysis by accounting for signal intensity differences as one additional option for DTI analysis. • We evaluated the effects of signal intensity differences at DTI registration. • The non-diffusion-weighted image re-calculation process from DTI data was applied. • SIMIC can minimise the signal intensity differences at DTI registration.
Ozturk, T; Bozgeyik, Z; Ozturk, F; Burakgazi, G; Akyol, M; Coskun, S; Ozkan, Y; Ogur, E
2015-08-01
The aim of this study was to evaluate the usefulness of diffusion-weighted magnetic resonance imaging (DWMRI) for differentation between Graves' disease and Hashimoto's thyroiditis. Fifty patients (27 Graves diseases and 23 Hashimoto thyroiditis) and twenty healthy volunteers were examined using T1, T2 and DWMRI. The patients were diagnosed on the basis of physical findings and the results of thyroid function tests and serological tests. Circular ROIs were positioned on the bilateral thyroid lobes and isthmus. All measurements were repeated three different b values including 100, 600 and 1000 s/mm2 in all cases. ADC (Apparent diffusion coefficient) maps were calculated automatically with the MR system. Mean ADC values were 2.93 × 10-3, 1.97 × 10-3 and 1.62 × 10-3 mm2/s in the healthy volunteers; 3.47 × 10-3, 2.25 × 10-3 and 1.64 × 10-3 mm2/s in Graves' disease; 2.53 × 10-3, 1.76 × 10-3, 1.28 × 10-3 mm2/s in Hashimoto thyroiditis for b100, b600 and b1000, respectively. The ADC values of the Graves diseases were higher than healty volunteers and Hashimoto thyroiditis. ADC values were statistically significant for differentation between Hashimoto thyroiditis and Graves' disease all b values (p < 0.05). DWMRI is fast sequence and does not require contrast agent. Quantitative assessment of the lesion is possible using ADC map. So, DWMRI may be useful differentiation of the Hashimoto thyroiditis and Graves' disease.
Nketiah, Gabriel; Selnaes, Kirsten M; Sandsmark, Elise; Teruel, Jose R; Krüger-Stokke, Brage; Bertilsson, Helena; Bathen, Tone F; Elschot, Mattijs
2018-05-01
To evaluate the effect of correction for B 0 inhomogeneity-induced geometric distortion in echo-planar diffusion-weighted imaging on quantitative apparent diffusion coefficient (ADC) analysis in multiparametric prostate MRI. Geometric distortion correction was performed in echo-planar diffusion-weighted images (b = 0, 50, 400, 800 s/mm 2 ) of 28 patients, using two b 0 scans with opposing phase-encoding polarities. Histology-matched tumor and healthy tissue volumes of interest delineated on T 2 -weighted images were mapped to the nondistortion-corrected and distortion-corrected data sets by resampling with and without spatial coregistration. The ADC values were calculated on the volume and voxel level. The effect of distortion correction on ADC quantification and tissue classification was evaluated using linear-mixed models and logistic regression, respectively. Without coregistration, the absolute differences in tumor ADC (range: 0.0002-0.189 mm 2 /s×10 -3 (volume level); 0.014-0.493 mm 2 /s×10 -3 (voxel level)) between the nondistortion-corrected and distortion-corrected were significantly associated (P < 0.05) with distortion distance (mean: 1.4 ± 1.3 mm; range: 0.3-5.3 mm). No significant associations were found upon coregistration; however, in patients with high rectal gas residue, distortion correction resulted in improved spatial representation and significantly better classification of healthy versus tumor voxels (P < 0.05). Geometric distortion correction in DWI could improve quantitative ADC analysis in multiparametric prostate MRI. Magn Reson Med 79:2524-2532, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Mardor, Yael; Pfeffer, Raphael; Spiegelmann, Roberto; Roth, Yiftach; Maier, Stephan E; Nissim, Ouzi; Berger, Raanan; Glicksman, Ami; Baram, Jacob; Orenstein, Arie; Cohen, Jack S; Tichler, Thomas
2003-03-15
To study the feasibility of using diffusion-weighted magnetic resonance imaging (DWMRI), which is sensitive to the diffusion of water molecules in tissues, for detection of early tumor response to radiation therapy; and to evaluate the additional information obtained from high DWMRI, which is more sensitive to low-mobility water molecules (such as intracellular or bound water), in increasing the sensitivity to response. Standard MRI and DWMRI were acquired before and at regular intervals after initiating radiation therapy for 10 malignant brain lesions in eight patients. One week posttherapy, three of six responding lesions showed an increase in the conventional DWMRI parameters. Another three responding lesions showed no change. Four nonresponding lesions showed a decrease or no change. The early change in the diffusion parameters was enhanced by using high DWMRI. When high DWMRI was used, all responding lesions showed increase in the diffusion parameter and all nonresponding lesions showed no change or decrease. Response was determined by standard MRI 7 weeks posttherapy. The changes in the diffusion parameters measured 1 week after initiating treatment were correlated with later tumor response or no response (P <.006). This correlation was increased to P <.0006 when high DWMRI was used. The significant correlation between changes in diffusion parameters 1 week after initiating treatment and later tumor response or no response suggests the feasibility of using DWMRI for early, noninvasive prediction of tumor response. The ability to predict response may enable early termination of treatment in nonresponding patients, prevent additional toxicity, and allow for early changes in treatment.
Seo, Nieun; Chung, Yong Eun; Park, Yung Nyun; Kim, Eunju; Hwang, Jinwoo; Kim, Myeong-Jin
2018-07-01
To compare the ability of diffusion-weighted imaging (DWI) parameters acquired from three different models for the diagnosis of hepatic fibrosis (HF). Ninety-five patients underwent DWI using nine b values at 3 T magnetic resonance. The hepatic apparent diffusion coefficient (ADC) from a mono-exponential model, the true diffusion coefficient (D t ), pseudo-diffusion coefficient (D p ) and perfusion fraction (f) from a biexponential model, and the distributed diffusion coefficient (DDC) and intravoxel heterogeneity index (α) from a stretched exponential model were compared with the pathological HF stage. For the stretched exponential model, parameters were also obtained using a dataset of six b values (DDC # , α # ). The diagnostic performances of the parameters for HF staging were evaluated with Obuchowski measures and receiver operating characteristics (ROC) analysis. The measurement variability of DWI parameters was evaluated using the coefficient of variation (CoV). Diagnostic accuracy for HF staging was highest for DDC # (Obuchowski measures, 0.770 ± 0.03), and it was significantly higher than that of ADC (0.597 ± 0.05, p < 0.001), D t (0.575 ± 0.05, p < 0.001) and f (0.669 ± 0.04, p = 0.035). The parameters from stretched exponential DWI and D p showed higher areas under the ROC curve (AUCs) for determining significant fibrosis (≥F2) and cirrhosis (F = 4) than other parameters. However, D p showed significantly higher measurement variability (CoV, 74.6%) than DDC # (16.1%, p < 0.001) and α # (15.1%, p < 0.001). Stretched exponential DWI is a promising method for HF staging with good diagnostic performance and fewer b-value acquisitions, allowing shorter acquisition time. • Stretched exponential DWI provides a precise and accurate model for HF staging. • Stretched exponential DWI parameters are more reliable than D p from bi-exponential DWI model • Acquisition of six b values is sufficient to obtain accurate DDC and α.
Phototransformation rate constants of PAHs associated with soot particles.
Kim, Daekyun; Young, Thomas M; Anastasio, Cort
2013-01-15
Photodegradation is a key process governing the residence time and fate of polycyclic aromatic hydrocarbons (PAHs) in particles, both in the atmosphere and after deposition. We have measured photodegradation rate constants of PAHs in bulk deposits of soot particles illuminated with simulated sunlight. The photodegradation rate constants at the surface (k(p)(0)), the effective diffusion coefficients (D(eff)), and the light penetration depths (z(0.5)) for PAHs on soot layers of variable thickness were determined by fitting experimental data with a model of coupled photolysis and diffusion. The overall disappearance rates of irradiated low molecular weight PAHs (with 2-3 rings) on soot particles were influenced by fast photodegradation and fast diffusion kinetics, while those of high molecular weight PAHs (with 4 or more rings) were apparently controlled by either the combination of slow photodegradation and slow diffusion kinetics or by very slow diffusion kinetics alone. The value of z(0.5) is more sensitive to the soot layer thickness than the k(p)(0) value. As the thickness of the soot layer increases, the z(0.5) values increase, but the k(p)(0) values are almost constant. The effective diffusion coefficients calculated from dark experiments are generally higher than those from the model fitting method for illumination experiments. Due to the correlation between k(p)(0) and z(0.5) in thinner layers, D(eff) should be estimated by an independent method for better accuracy. Despite some limitations of the model used in this study, the fitted parameters were useful for describing empirical results of photodegradation of soot-associated PAHs. Copyright © 2012 Elsevier B.V. All rights reserved.
Whole body MRI: Improved Lesion Detection and Characterization With Diffusion Weighted Techniques
Attariwala, Rajpaul; Picker, Wayne
2013-01-01
Diffusion-weighted imaging (DWI) is an established functional imaging technique that interrogates the delicate balance of water movement at the cellular level. Technological advances enable this technique to be applied to whole-body MRI. Theory, b-value selection, common artifacts and target to background for optimized viewing will be reviewed for applications in the neck, chest, abdomen, and pelvis. Whole-body imaging with DWI allows novel applications of MRI to aid in evaluation of conditions such as multiple myeloma, lymphoma, and skeletal metastases, while the quantitative nature of this technique permits evaluation of response to therapy. Persisting signal at high b-values from restricted hypercellular tissue and viscous fluid also permits applications of DWI beyond oncologic imaging. DWI, when used in conjunction with routine imaging, can assist in detecting hemorrhagic degradation products, infection/abscess, and inflammation in colitis, while aiding with discrimination of free fluid and empyema, while limiting the need for intravenous contrast. DWI in conjunction with routine anatomic images provides a platform to improve lesion detection and characterization with findings rivaling other combined anatomic and functional imaging techniques, with the added benefit of no ionizing radiation. PMID:23960006
NASA Astrophysics Data System (ADS)
Magin, Richard L.; Akpa, Belinda S.; Neuberger, Thomas; Webb, Andrew G.
2011-12-01
We report the appearance of anomalous water diffusion in hydrophilic Sephadex gels observed using pulse field gradient (PFG) nuclear magnetic resonance (NMR). The NMR diffusion data was collected using a Varian 14.1 Tesla imaging system with a home-built RF saddle coil. A fractional order analysis of the data was used to characterize heterogeneity in the gels for the dynamics of water diffusion in this restricted environment. Several recent studies of anomalous diffusion have used the stretched exponential function to model the decay of the NMR signal, i.e., exp[-( bD) α], where D is the apparent diffusion constant, b is determined the experimental conditions (gradient pulse separation, durations and strength), and α is a measure of structural complexity. In this work, we consider a different case where the spatial Laplacian in the Bloch-Torrey equation is generalized to a fractional order model of diffusivity via a complexity parameter, β, a space constant, μ, and a diffusion coefficient, D. This treatment reverts to the classical result for the integer order case. The fractional order decay model was fit to the diffusion-weighted signal attenuation for a range of b-values (0 < b < 4000 s mm -2). Throughout this range of b values, the parameters β, μ and D, were found to correlate with the porosity and tortuosity of the gel structure.
Cao, Mengqiu; Suo, Shiteng; Han, Xu; Jin, Ke; Sun, Yawen; Wang, Yao; Ding, Weina; Qu, Jianxun; Zhang, Xiaohua; Zhou, Yan
2017-01-01
Purpose : To evaluate the feasibility of a simplified method based on diffusion-weighted imaging (DWI) acquired with three b -values to measure tissue perfusion linked to microcirculation, to validate it against from perfusion-related parameters derived from intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging, and to investigate its utility to differentiate low- from high-grade gliomas. Materials and Methods : The prospective study was approved by the local institutional review board and written informed consent was obtained from all patients. From May 2016 and May 2017, 50 patients confirmed with glioma were assessed with multi- b -value DWI and DCE MR imaging at 3.0 T. Besides conventional apparent diffusion coefficient (ADC 0,1000 ) map, perfusion-related parametric maps for IVIM-derived perfusion fraction ( f ) and pseudodiffusion coefficient (D*), DCE MR imaging-derived pharmacokinetic metrics, including K trans , v e and v p , as well as a metric named simplified perfusion fraction (SPF), were generated. Correlation between perfusion-related parameters was analyzed by using the Spearman rank correlation. All imaging parameters were compared between the low-grade ( n = 19) and high-grade ( n = 31) groups by using the Mann-Whitney U test. The diagnostic performance for tumor grading was evaluated with receiver operating characteristic (ROC) analysis. Results : SPF showed strong correlation with IVIM-derived f and D* ( ρ = 0.732 and 0.716, respectively; both P < 0.001). Compared with f , SPF was more correlated with DCE MR imaging-derived K trans ( ρ = 0.607; P < 0.001) and v p ( ρ = 0.397; P = 0.004). Among all parameters, SPF achieved the highest accuracy for differentiating low- from high-grade gliomas, with an area under the ROC curve value of 0.942, which was significantly higher than that of ADC 0,1000 ( P = 0.004). By using SPF as a discriminative index, the diagnostic sensitivity and specificity were 87.1% and 94.7%, respectively, at the optimal cut-off value of 19.26%. Conclusion : The simplified method to measure tissue perfusion based on DWI by using three b -values may be helpful to differentiate low- from high-grade gliomas. SPF may serve as a valuable alternative to measure tumor perfusion in gliomas in a noninvasive, convenient and efficient way.
Automated pixel-wise brain tissue segmentation of diffusion-weighted images via machine learning.
Ciritsis, Alexander; Boss, Andreas; Rossi, Cristina
2018-04-26
The diffusion-weighted (DW) MR signal sampled over a wide range of b-values potentially allows for tissue differentiation in terms of cellularity, microstructure, perfusion, and T 2 relaxivity. This study aimed to implement a machine learning algorithm for automatic brain tissue segmentation from DW-MRI datasets, and to determine the optimal sub-set of features for accurate segmentation. DWI was performed at 3 T in eight healthy volunteers using 15 b-values and 20 diffusion-encoding directions. The pixel-wise signal attenuation, as well as the trace and fractional anisotropy (FA) of the diffusion tensor, were used as features to train a support vector machine classifier for gray matter, white matter, and cerebrospinal fluid classes. The datasets of two volunteers were used for validation. For each subject, tissue classification was also performed on 3D T 1 -weighted data sets with a probabilistic framework. Confusion matrices were generated for quantitative assessment of image classification accuracy in comparison with the reference method. DWI-based tissue segmentation resulted in an accuracy of 82.1% on the validation dataset and of 82.2% on the training dataset, excluding relevant model over-fitting. A mean Dice coefficient (DSC) of 0.79 ± 0.08 was found. About 50% of the classification performance was attributable to five features (i.e. signal measured at b-values of 5/10/500/1200 s/mm 2 and the FA). This reduced set of features led to almost identical performances for the validation (82.2%) and the training (81.4%) datasets (DSC = 0.79 ± 0.08). Machine learning techniques applied to DWI data allow for accurate brain tissue segmentation based on both morphological and functional information. Copyright © 2018 John Wiley & Sons, Ltd.
Van Steenkiste, Gwendolyn; Jeurissen, Ben; Veraart, Jelle; den Dekker, Arnold J; Parizel, Paul M; Poot, Dirk H J; Sijbers, Jan
2016-01-01
Diffusion MRI is hampered by long acquisition times, low spatial resolution, and a low signal-to-noise ratio. Recently, methods have been proposed to improve the trade-off between spatial resolution, signal-to-noise ratio, and acquisition time of diffusion-weighted images via super-resolution reconstruction (SRR) techniques. However, during the reconstruction, these SRR methods neglect the q-space relation between the different diffusion-weighted images. An SRR method that includes a diffusion model and directly reconstructs high resolution diffusion parameters from a set of low resolution diffusion-weighted images was proposed. Our method allows an arbitrary combination of diffusion gradient directions and slice orientations for the low resolution diffusion-weighted images, optimally samples the q- and k-space, and performs motion correction with b-matrix rotation. Experiments with synthetic data and in vivo human brain data show an increase of spatial resolution of the diffusion parameters, while preserving a high signal-to-noise ratio and low scan time. Moreover, the proposed SRR method outperforms the previous methods in terms of the root-mean-square error. The proposed SRR method substantially increases the spatial resolution of MRI that can be obtained in a clinically feasible scan time. © 2015 Wiley Periodicals, Inc.
Dynamic characteristics of MR diffusion-weighted imaging in a rabbit liver VX-2 tumor model.
Yuan, You-Hong; Xiao, En-Hua; He, Zhong; Jin, Ke; Ma, Cong; Xiang, Jun; Xiao, Jian-Hua; Chen, Wei-Jian
2013-02-01
To investigate prospectively dynamic characteristics of the apparent diffusion coefficient (ADC) on MR diffusion-weighted imaging (DWI) in a rabbit VX-2 tumor model. Forty New Zealand rabbits were included in the study, and 47 rabbit VX-2 tumor models were developed by direct and intrahepatic implantation after opening the abdominal cavities. DWI was carried out periodically and respectively on days 7, 14 and 21 after implantation. The VX-2 tumor samples were studied by pathology. The distinction of VX-2 tumors on DWI was assessed by their ADC values by analysis of variance (ANOVA) using SPSS12.0 software. The ADC values (mean ± SD) × 10(-3) mm(2)/s of 47 VX-2 tumors in the peripheral and central areas were 2.18 ± 0.29, 1.96 ± 0.33, 1.80 ± 0.35, 2.20 ± 0.29, 2.05 ± 0.30 and 1.96 ± 0.48, respectively, on days 7, 14 and 21 after implantation. ADC values of 47 VX-2 tumors in the area of the tumor periphery, center and normal parenchyma were higher when the b-value was 100 s/mm(2) than those when the b-value was 300 s/mm(2) (F = 17.964, p < 0.001; F = 13.986, p < 0.001; F = 128.681, p < 0.001). ADC values in the area of normal liver parenchyma were higher than those in the area of the VX-2 tumor periphery and center when the b-value was 100 or 300 s/mm(2). ADCs of viable tumor cells in VX-2 tumors were lower on DWI than those in the area of normal liver parenchyma around the tumor, and ADCs of dead tumor cells in VX-2 tumors were unequal, including high, equal and low values, but they were higher than in the area of normal liver parenchyma around tumors after dead tumor cells had been liquefied or had become cystic. ADC is correlated with the tumor histology and degree of malignancy, and DWI has potential value for dynamically monitoring tumors and evaluating the degree of malignancy and therapeutic effect.
Jones, D K; Alexander, D C; Bowtell, R; Cercignani, M; Dell'Acqua, F; McHugh, D J; Miller, K L; Palombo, M; Parker, G J M; Rudrapatna, U S; Tax, C M W
2018-05-22
The key component of a microstructural diffusion MRI 'super-scanner' is a dedicated high-strength gradient system that enables stronger diffusion weightings per unit time compared to conventional gradient designs. This can, in turn, drastically shorten the time needed for diffusion encoding, increase the signal-to-noise ratio, and facilitate measurements at shorter diffusion times. This review, written from the perspective of the UK National Facility for In Vivo MR Imaging of Human Tissue Microstructure, an initiative to establish a shared 300 mT/m-gradient facility amongst the microstructural imaging community, describes ten advantages of ultra-strong gradients for microstructural imaging. Specifically, we will discuss how the increase of the accessible measurement space compared to a lower-gradient systems (in terms of Δ, b-value, and TE) can accelerate developments in the areas of 1) axon diameter distribution mapping; 2) microstructural parameter estimation; 3) mapping micro-vs macroscopic anisotropy features with gradient waveforms beyond a single pair of pulsed-gradients; 4) multi-contrast experiments, e.g. diffusion-relaxometry; 5) tractography and high-resolution imaging in vivo and 6) post mortem; 7) diffusion-weighted spectroscopy of metabolites other than water; 8) tumour characterisation; 9) functional diffusion MRI; and 10) quality enhancement of images acquired on lower-gradient systems. We finally discuss practical barriers in the use of ultra-strong gradients, and provide an outlook on the next generation of 'super-scanners'. Copyright © 2018. Published by Elsevier Inc.
Harada, Taiyo L; Saito, Kazuhiro; Araki, Yoichi; Matsubayashi, Jun; Nagao, Toshitaka; Sugimoto, Katsutoshi; Tokuuye, Koichi
2018-05-01
Background Recently, diffusion-weighted imaging (DWI) and quantitative enhancement ratio measured at the hepatobiliary phase (HBP) of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) has been established as an effective method for evaluating liver fibrosis. Purpose To evaluate which is a more favorable surrogate marker in predicting high-stage liver fibrosis, apparently diffusion coefficient (ADC) value or quantitative enhancement ratio measured on HBP. Material and Methods Eighty-three patients with 99 surgically resected hepatic lesions were enrolled in this study. DWI was performed with b-values of 100 and 800 s/mm 2 . Regions of interest were set on ADC map, and the HBP of Gd-EOB-DTPA-enhanced MRI, to calculate ADC value, liver-to-muscle ratio (LMR), liver-to-spleen ratio (LSR), and contrast enhancement index (CEI) of liver. We compared these parameters between low-stage fibrosis (F0, F1, and F2) and high-stage fibrosis (F3 and F4). Receiver operating characteristic analysis was performed to compare the diagnostic performance when distinguishing low-stage fibrosis from high-stage fibrosis. Results LMR and CEI were significantly lower at high-stage fibrosis than at the low stage ( P < 0.01 and P = 0.04, respectively), whereas LSR did not show a significant difference ( P = 0.053). No significant difference was observed in diagnostic performance between LMR and CEI ( P = 0.185). The best sensitivity and specificity, when an LMR of 2.80 or higher was considered to be low-stage fibrosis, were 82.4% and 75.6%, respectively. ADC value showed no significant differences among fibrosis grades ( P = 0.320). Conclusion LMR and CEI were both adequate surrogate parameters to distinguish high-stage fibrosis from low-stage fibrosis.
Woodhams, Reiko; Kakita, Satoko; Hata, Hirofumi; Iwabuchi, Keiichi; Umeoka, Shigeaki; Mountford, Carolyn E; Hatabu, Hiroto
2009-07-01
The purposes of this study were to compare the apparent diffusion coefficient (ADC) of mucinous carcinoma of the breast with that of other breast tumors and to analyze correlations between signal intensity on diffusion-weighted images and the histologic features of mucinous carcinoma. Two hundred seventy-six patients with 277 lesions, including 15 mucinous carcinomas (13 pure type, two mixed type), 204 other malignant tumors, and 58 benign lesions, were examined with 1.5-T MRI at b values of 0 and 1,500 s/mm(2). The correlations between cellularity and ADC, homogeneity of signal intensity on diffusion-weighted images, and histopathologic findings were analyzed. The difference was statistically significant (p < 0.05). The mean ADC of mucinous carcinoma (1.8 +/- 0.4 x 10(-3) mm(2)/s) was statistically higher than that of benign lesions (1.3+/- 0.3 x 10(-3) mm(2)/s) and other malignant tumors (0.9 +/- 0.2 x 10(-3) mm(2)/s) (p < 0.001). The ADC of pure type mucinous carcinoma (1.8 +/- 0.3 x 10(-3) mm(2)/s) was higher than that of mixed type mucinous carcinoma (1.2 +/- 0.2 x 10(-3) mm(2)/s) (p < 0.001) and other histologic types (p > 0.05). The correlation between mean cellularity and the ADC of mucinous carcinoma was significant (rho(s) = -0.754; p = 0.001). The homogeneity of signal intensity on diffusion-weighted images correlated with the homogeneity of histologic structures of mucinous carcinoma (p < 0.001; kappa = 0.826). Mucinous carcinoma can be clearly differentiated from other breast tumors on the basis of ADC. The low signal intensity of mucinous carcinoma on diffusion-weighted images appears to reflect the presence of mucin and low cellularity. High signal intensity on diffusion-weighted images may reflect the presence of fibrovascular bundles, increased cell density, or a combination of these features.
Effect of diffusion time on liver DWI: an experimental study of normal and fibrotic livers.
Zhou, Iris Y; Gao, Darwin S; Chow, April M; Fan, Shujuan; Cheung, Matthew M; Ling, Changchun; Liu, Xiaobing; Cao, Peng; Guo, Hua; Man, Kwan; Wu, Ed X
2014-11-01
To investigate whether diffusion time (Δ) affects the diffusion measurements in liver and their sensitivity in detecting fibrosis. Liver fibrosis was induced in Sprague-Dawley rats (n = 12) by carbon tetrachloride (CCl(4)) injections. Diffusion-weighted MRI was performed longitudinally during 8-week CCl(4) administration at 7 Tesla (T) using single-shot stimulated-echo EPI with five b-values (0 to 1000 s/mm(2)) and three Δs. Apparent diffusion coefficient (ADC) and true diffusion coefficient (D(true)) were calculated by using all five b-values and large b-values, respectively. ADC and D(true) decreased with Δ for both normal and fibrotic liver at each time point. ADC and D(true) also generally decreased with the time after CCl(4) insult. The reductions in D(true) between 2-week and 4-week CCl(4) insult were larger than the ADC reductions at all Δs. At each time point, D(true) measured with long Δ (200 ms) detected the largest changes among the 3 Δs examined. Histology revealed gradual collagen deposition and presence of intracellular fat vacuoles after CCl(4) insult. Our results demonstrated the Δ dependent diffusion measurements, indicating restricted diffusion in both normal and fibrotic liver. D(true) measured with long Δ acted as a more sensitive index of the pathological alterations in liver microstructure during fibrogenesis. Copyright © 2013 Wiley Periodicals, Inc.
Shi, Changzheng; Zhang, Dong; Xiao, Zeyu; Wang, Li; Ma, Rong; Chen, Hanwei; Luo, Liangping
2017-09-01
To investigate the reproducibility of diffusion-weighted imaging (DWI) with ultrahigh b-values, and analyze the age-related differences in normal prostates. In all, 67 healthy participants were divided into three age groups (group A, 15-30 years; group B, 31-50 years; group C, ≥51 years), and underwent DWI scanning twice with 15 b-factors from 0 to 3000 at 3.0T. Triexponential fits were applied to calculate the molecular diffusion coefficient (D), the pseudo-diffusion coefficient (D*), the ultrahigh apparent diffusion coefficient (ADC uh ), and perfusion fraction (f). The interobserver and short-term interscan reproducibility were evaluated, and the change in these parameters with age were assessed. The D, ADC uh , and f values presented good to excellent reproducibility. With increasing age, a trend of increasing D values was observed, with significant difference in both peripheral zone (PZ, P = 0.01) and central gland (CG, P = 0.01) of normal prostate tissue. The f value increased in the CG beginning at 50 years of age while the ADC uh value decreased in the PZ after 50 years of age; all of them showed significant differences between groups A and C and groups B and C (P = 0.01/0.01). The D, ADC uh , and f values have good to excellent reproducibility in the normal prostate, and these values change with age. The ultrahigh b-values magnetic resonance imaging (MRI) can provide additional information (ADC uh ), which is different from the IVIM (intravoxel incoherent motion)-derived parameters. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:801-812. © 2017 International Society for Magnetic Resonance in Medicine.
TU-H-CAMPUS-IeP2-01: Quantitative Evaluation of PROPELLER DWI Using QIBA Diffusion Phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yung, J; Ai, H; Liu, H
Purpose: The purpose of this study is to determine the quantitative variability of apparent diffusion coefficient (ADC) values when varying imaging parameters in a diffusion-weighted (DW) fast spin echo (FSE) sequence with Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) k-space trajectory. Methods: Using a 3T MRI scanner, a NIST traceable, quantitative magnetic resonance imaging (MRI) diffusion phantom (High Precision Devices, Inc, Boulder, Colorado) consisting of 13 vials filled with various concentrations of polymer polyvinylpyrrolidone (PVP) in aqueous solution was imaged with a standard Quantitative Imaging Biomarkers Alliance (QIBA) DWI spin echo, echo planar imaging (SE EPI) acquisition. Themore » same phantom was then imaged with a DWI PROPELLER sequence at varying echo train lengths (ETL) of 8, 20, and 32, as well as b-values of 400, 900, and 2000. QIBA DWI phantom analysis software was used to generate ADC maps and create region of interests (ROIs) for quantitative measurements of each vial. Mean and standard deviations of the ROIs were compared. Results: The SE EPI sequence generated ADC values that showed very good agreement with the known ADC values of the phantom (r2 = 0.9995, slope = 1.0061). The ADC values measured from the PROPELLER sequences were inflated, but were highly correlated with an r2 range from 0.8754 to 0.9880. The PROPELLER sequence with an ETL=20 and b-value of 0 and 2000 showed the closest agreement (r2 = 0.9034, slope = 0.9880). Conclusion: The DW PROPELLER sequence is promising for quantitative evaluation of ADC values. A drawback of the PROPELLER sequence is the longer acquisition time. The 180° refocusing pulses may also cause the observed increase in ADC values compared to the standard SE EPI DW sequence. However, the FSE sequence offers an advantage with in-plane motion and geometric distortion which will be investigated in future studies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyagi, N; Wengler, K; Yorke, E
2014-06-15
Purpose: To investigate early changes in tumor Apparent Diffusion Coefficients derived from diffusion weighted (DW)-MRI of lung cancer patients undergoing SBRT, as a possible early predictor of treatment response. Methods: DW-MRI scans were performed in this prospective phase I IRB-approved study of inoperable lung tumors at various time-points during the course of SBRT treatments. Axial DW scan using multi b-values ranging from 0–1000 s/mm{sup 2} were acquired in treatment position on a 3T Philips MR scanner during simulation, one hour after the first fraction (8 Gy), after a total of 5 fractions (40 Gy) and 4 weeks after SBRT delivery.more » A monoexponential model based on a least square fit from all b values was performed on a pixel-by-pixel basis and ADC was calculated. GTVs drawn on 4DCT for planning were mapped on the T2w MRI (acquired at exhale) after deformable registration. These volumes were then mapped on DWI scan for ADC calculation after rigid registration between the anatomical scan and diffusion scan. T2w scan on followup time points were deformably registered to the pretreatment T2 scan. Results: The first two patients in this study were analyzed. Median ADC values were 1.48, 1.48, 1.62 and 1.83 (10{sup −3}×) mm{sup 2}/s at pretreatment, after 8 Gy, after 40 Gy and 4 weeks posttreatment for the first patient and 1.57, 1.53, 1.66 and 1.72 (10{sup −3}×) mm{sup 2}/s for the second patient. ADC increased more significantly after 4 weeks of treatment rather than immediately post treatment, implying that late ADC value may be a better predictor of tumor response for SBRT treatment. The fraction of tumor pixels at high ADC values increased at 4 weeks post treatment. Conclusion: The observed increase in ADC values before the end of radiotherapy may be a surrogate for tumor response, but further patient accrual will be necessary to determine its value.« less
Comparison of diffusion-weighted MRI acquisition techniques for normal pancreas at 3.0 Tesla.
Yao, Xiu-Zhong; Kuang, Tiantao; Wu, Li; Feng, Hao; Liu, Hao; Cheng, Wei-Zhong; Rao, Sheng-Xiang; Wang, He; Zeng, Meng-Su
2014-01-01
We aimed to optimize diffusion-weighted imaging (DWI) acquisitions for normal pancreas at 3.0 Tesla. Thirty healthy volunteers were examined using four DWI acquisition techniques with b values of 0 and 600 s/mm2 at 3.0 Tesla, including breath-hold DWI, respiratory-triggered DWI, respiratory-triggered DWI with inversion recovery (IR), and free-breathing DWI with IR. Artifacts, signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) of normal pancreas were statistically evaluated among different DWI acquisitions. Statistical differences were noticed in artifacts, SNR, and ADC values of normal pancreas among different DWI acquisitions by ANOVA (P <0.001). Normal pancreas imaging had the lowest artifact in respiratory-triggered DWI with IR, the highest SNR in respiratory-triggered DWI, and the highest ADC value in free-breathing DWI with IR. The head, body, and tail of normal pancreas had statistically different ADC values on each DWI acquisition by ANOVA (P < 0.05). The highest image quality for normal pancreas was obtained using respiratory-triggered DWI with IR. Normal pancreas displayed inhomogeneous ADC values along the head, body, and tail structures.
Shimada, Kotaro; Isoda, Hiroyoshi; Hirokawa, Yuusuke; Arizono, Shigeki; Shibata, Toshiya; Togashi, Kaori
2010-11-01
To compare the accuracy of gadolinium ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI with that of diffusion-weighted MRI (DWI) in the detection of small hepatic metastases (2 cm or smaller). Forty-five patients underwent abdominal MRI at 3 T, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), heavily T2WI (HASTE), DWI with a b-value of 500 s/mm(2) and contrast-enhanced MRI with Gd-EOB-DTPA. Two groups were assigned and compared: group A (T1WI, T2WI, HASTE and contrast-enhanced study with Gd-EOB-DTPA), and group B (T1WI, T2WI, HASTE and DWI). Two observers independently interpreted the images obtained in a random order. For all hepatic metastases, the diagnostic performance using each imaging set was evaluated by receiver-operating characteristic (ROC) curve analysis. A total of 51 hepatic metastases were confirmed. The area under the ROC curve (Az) of group A was larger than that of group B, and the difference in the mean Az values between the two image sets was statistically significant, whereas, there were three metastases that lay near thin vessels or among multiple cysts and were better visualised in group B than in group A. Gd-EOB-DTPA-enhanced MRI showed higher accuracy in the detection of small metastases than DWI.
Portnoy, S; Flint, J J; Blackband, S J; Stanisz, G J
2013-04-01
Oscillating gradient spin-echo (OGSE) pulse sequences have been proposed for acquiring diffusion data with very short diffusion times, which probe tissue structure at the subcellular scale. OGSE sequences are an alternative to pulsed gradient spin echo measurements, which typically probe longer diffusion times due to gradient limitations. In this investigation, a high-strength (6600 G/cm) gradient designed for small-sample microscopy was used to acquire OGSE and pulsed gradient spin echo data in a rat hippocampal specimen at microscopic resolution. Measurements covered a broad range of diffusion times (TDeff = 1.2-15.0 ms), frequencies (ω = 67-1000 Hz), and b-values (b = 0-3.2 ms/μm2). Variations in apparent diffusion coefficient with frequency and diffusion time provided microstructural information at a scale much smaller than the imaging resolution. For a more direct comparison of the techniques, OGSE and pulsed gradient spin echo data were acquired with similar effective diffusion times. Measurements with similar TDeff were consistent at low b-value (b < 1 ms/μm(2) ), but diverged at higher b-values. Experimental observations suggest that the effective diffusion time can be helpful in the interpretation of low b-value OGSE data. However, caution is required at higher b, where enhanced sensitivity to restriction and exchange render the effective diffusion time an unsuitable representation. Oscillating and pulsed gradient diffusion techniques offer unique, complementary information. In combination, the two methods provide a powerful tool for characterizing complex diffusion within biological tissues. Copyright © 2012 Wiley Periodicals, Inc.
Callot, Virginie; Duhamel, Guillaume; Cozzone, Patrick J; Kober, Frank
2008-10-01
Mouse spinal cord (SC) diffusion-weighted imaging (DWI) provides important information on tissue morphology and structural changes that may occur during pathologies such as multiple sclerosis or SC injury. The acquisition scheme of the commonly used DWI techniques is based on conventional spin-echo encoding, which is time-consuming. The purpose of this work was to investigate whether the use of echo planar imaging (EPI) would provide good-quality diffusion MR images of mouse SC, as well as accurate measurements of diffusion-derived metrics, and thus enable diffusion tensor imaging (DTI) and highly resolved DWI within reasonable scan times. A four-shot diffusion-weighted spin-echo EPI (SE-EPI) sequence was evaluated at 11.75 T on a group of healthy mice (n = 10). SE-EPI-derived apparent diffusion coefficients of gray and white matter were compared with those obtained using a conventional spin-echo sequence (c-SE) to validate the accuracy of the method. To take advantage of the reduction in acquisition time offered by the EPI sequence, multi-slice DTI acquisitions were performed covering the cervical segments (six slices, six diffusion-encoding directions, three b values) within 30 min (vs 2 h for c-SE). From these measurements, fractional anisotropy and mean diffusivities were calculated, and fiber tracking along the C1 to C6 cervical segments was performed. In addition, high-resolution images (74 x 94 microm(2)) were acquired within 5 min per direction. Clear delineation of gray and white matter and identical apparent diffusion coefficient values were obtained, with a threefold reduction in acquisition time compared with c-SE. While overcoming the difficulties associated with high spatially and temporally resolved DTI measurements, the present SE-EPI approach permitted identification of reliable quantitative parameters with a reproducibility compatible with the detection of pathologies. The SE-EPI method may be particularly valuable when multiple sets of images from the SC are needed, in cases of rapidly evolving conditions, to decrease the duration of anesthesia or to improve MR exploration by including additional MR measurements. Copyright (c) 2008 John Wiley & Sons, Ltd.
Nicolas, Renaud; Sibon, Igor; Hiba, Bassem
2015-01-01
The diffusion-weighted-dependent attenuation of the MRI signal E(b) is extremely sensitive to microstructural features. The aim of this study was to determine which mathematical model of the E(b) signal most accurately describes it in the brain. The models compared were the monoexponential model, the stretched exponential model, the truncated cumulant expansion (TCE) model, the biexponential model, and the triexponential model. Acquisition was performed with nine b-values up to 2500 s/mm(2) in 12 healthy volunteers. The goodness-of-fit was studied with F-tests and with the Akaike information criterion. Tissue contrasts were differentiated with a multiple comparison corrected nonparametric analysis of variance. F-test showed that the TCE model was better than the biexponential model in gray and white matter. Corrected Akaike information criterion showed that the TCE model has the best accuracy and produced the most reliable contrasts in white matter among all models studied. In conclusion, the TCE model was found to be the best model to infer the microstructural properties of brain tissue.
Higher-Order Motion-Compensation for In Vivo Cardiac Diffusion Tensor Imaging in Rats
Welsh, Christopher L.; DiBella, Edward V. R.; Hsu, Edward W.
2015-01-01
Motion of the heart has complicated in vivo applications of cardiac diffusion MRI and diffusion tensor imaging (DTI), especially in small animals such as rats where ultra-high-performance gradient sets are currently not available. Even with velocity compensation via, for example, bipolar encoding pulses, the variable shot-to-shot residual motion-induced spin phase can still give rise to pronounced artifacts. This study presents diffusion-encoding schemes that are designed to compensate for higher-order motion components, including acceleration and jerk, which also have the desirable practical features of minimal TEs and high achievable b-values. The effectiveness of these schemes was verified numerically on a realistic beating heart phantom, and demonstrated empirically with in vivo cardiac diffusion MRI in rats. Compensation for acceleration, and lower motion components, was found to be both necessary and sufficient for obtaining diffusion-weighted images of acceptable quality and SNR, which yielded the first in vivo cardiac DTI demonstrated in the rat. These findings suggest that compensation for higher order motion, particularly acceleration, can be an effective alternative solution to high-performance gradient hardware for improving in vivo cardiac DTI. PMID:25775486
Bernardin, L; Douglas, N H M; Collins, D J; Giles, S L; O'Flynn, E A M; Orton, M; deSouza, N M
2014-02-01
To establish repeatability of apparent diffusion coefficients (ADCs) acquired from free-breathing diffusion-weighted magnetic resonance imaging (DW-MRI) in malignant lung lesions and investigate effects of lesion size, location and respiratory motion. Thirty-six malignant lung lesions (eight patients) were examined twice (1- to 5-h interval) using T1-weighted, T2-weighted and axial single-shot echo-planar DW-MRI (b = 100, 500, 800 s/mm(2)) during free-breathing. Regions of interest around target lesions on computed b = 800 s/mm(2) images by two independent observers yielded ADC values from maps (pixel-by-pixel fitting using all b values and a mono-exponential decay model). Intra- and inter-observer repeatability was assessed per lesion, per patient and by lesion size (> or <2 cm) or location. ADCs were similar between observers (mean ± SD, 1.15 ± 0.28 × 10(-3) mm(2)/s, observer 1; 1.15 ± 0.29 × 10(-3) mm(2)/s, observer 2). Intra-observer coefficients of variation of the mean [median] ADC per lesion and per patient were 11% [11.4%], 5.7% [5.7%] for observer 1 and 9.2% [9.5%], 3.9% [4.7%] for observer 2 respectively; inter-observer values were 8.9% [9.3%] (per lesion) and 3.0% [3.7%] (per patient). Inter-observer coefficient of variation (CoV) was greater for lesions <2 cm (n = 20) compared with >2 cm (n = 16) (10.8% vs 6.5% ADCmean, 11.3% vs 6.7% ADCmedian) and for mid (n = 14) vs apical (n = 9) or lower zone (n = 13) lesions (13.9%, 2.7%, 3.8% respectively ADCmean; 14.2%, 2.8%, 4.7% respectively ADCmedian). Free-breathing DW-MRI of whole lung achieves good intra- and inter-observer repeatability of ADC measurements in malignant lung tumours. • Diffusion-weighted MRI of the lung can be satisfactorily acquired during free-breathing • DW-MRI demonstrates high contrast between primary and metastatic lesions and normal lung • Apparent diffusion coefficient (ADC) measurements in lung tumours are repeatable and reliable • ADC offers potential in assessing response in lung metastases in clinical trials.
Lv, Jun; Huang, Wenjian; Zhang, Jue; Wang, Xiaoying
2018-06-01
In free-breathing multi-b-value diffusion-weighted imaging (DWI), a series of images typically requires several minutes to collect. During respiration the kidney is routinely displaced and may also undergo deformation. These respiratory motion effects generate artifacts and these are the main sources of error in the quantification of intravoxel incoherent motion (IVIM) derived parameters. This work proposes a fully automated framework that combines a kidney segmentation to improve the registration accuracy. 10 healthy subjects were recruited to participate in this experiment. For the segmentation, U-net was adopted to acquire the kidney's contour. The segmented kidney then served as a region of interest (ROI) for the registration method, known as pyramidal Lucas-Kanade. Our proposed framework confines the kidney's solution range, thus increasing the pyramidal Lucas-Kanade's accuracy. To demonstrate the feasibility of our presented framework, eight regions of interest were selected in the cortex and medulla, and data stability was estimated by comparing the normalized root-mean-square error (NRMSE) values of the fitted data from the bi-exponential intravoxel incoherent motion model pre- and post- registration. The results show that the NRMSE was significantly lower after registration both in the cortex (p < 0.05) and medulla (p < 0.01) during free-breathing measurements. In addition, expert visual scoring of the derived apparent diffusion coefficient (ADC), f, D and D* maps indicated there were significant improvements in the alignment of the kidney in the post-registered image. The proposed framework can effectively reduce the motion artifacts of misaligned multi-b-value DWIs and the inaccuracies of the ADC, f, D and D* estimations. Advances in knowledge: This study demonstrates the feasibility of our proposed fully automated framework combining U-net based segmentation and pyramidal Lucas-Kanade registration method for improving the alignment of multi-b-value diffusion-weighted MRIs and reducing the inaccuracy of parameter estimation during free-breathing.
Abuhandan, M; Cece, H; Calik, M; Karakas, E; Dogan, F; Karakas, O
2013-03-01
This study aimed to evaluate the contribution of diffusion weighted magnetic resonance imaging to the diagnosis and staging of subacute sclerosing panencephalitis. The study comprised 26 patients diagnosed with subacute sclerosing panencephalitis at our clinic who were undergoing regular follow-up, and a control group of 18 subjects. Clinical staging was determined by Risk and Haddad classification; 12 at Stage II and 14 at Stage III. Diffusion weighted magnetic resonance images were taken of six areas (frontal, parieto-occipital, cerebellar, deep white matter, thalamus and basal ganglia) and by calculating the apparent diffusion coefficient (ADC) values, and a comparison was made between the stages and with the control group. The ADC values of all the areas of the subacute sclerosing panencephalitis patients were found to be significantly higher compared to the control group (p < 0.05). While the mean ADC values of the deep white matter, basal ganglia, frontal and parieto-occipital areas of the Stage II patients were found to be significant compared to the control group (p < 0.05), there was no significance in the other areas (p > 0.05). The ADC values of all the areas of the Stage III patients were found to be significantly high compared to the Stage II values (p < 0.05). Diffusion weighted magnetic resonance imaging can be used with other diagnostic criteria to confirm diagnosis of subacute sclerosing panencephalitis and to reveal differences between the stages.
Development and Initial Evaluation of 7 Tesla Q-Ball Imaging of the Human Brain
Mukherjee, Pratik; Hess, Christopher P.; Xu, Duan; Han, Eric T.; Kelley, Douglas A.; Vigneron, Daniel B.
2010-01-01
Diffusion tensor imaging (DTI) noninvasively depicts white matter connectivity in regions where the Gaussian model of diffusion is valid, but yields inaccurate results where diffusion has a more complex distribution, such as fiber crossings. Q-ball imaging (QBI) overcomes this limitation of DTI by more fully characterizing the angular dependence of intravoxel diffusion with larger numbers of diffusion-encoding directional measurements at higher diffusion-weighting factors (b values). However, the former results in longer acquisition times and the latter results in lower signal-to-noise ratio (SNR). In this project, we developed specialized 7 Tesla acquisition methods utilizing novel radiofrequency pulses, 8-channel parallel imaging EPI, and high-order shimming with a phase-sensitive multichannel B0 field map reconstruction. These methods were applied in initial healthy adult volunteer studies which demonstrated the feasibility of performing 7T QBI. Preliminary comparisons of 3T with 7T within supratentorial crossing white matter tracts document a 79.5% SNR increase for b=3000 s/mm2 (p=0.0001), and a 38.6% SNR increase for b=6000 s/mm2 (p=0.015). Using spherical harmonic reconstruction of the q-ball orientation distribution function at b=3000 s/mm2, 7T QBI allowed accurate visualization of crossing fiber tracts with fewer diffusion-encoding acquisitions than at 3T. The improvement of 7T QBI at b factors as high as 6000 s/mm2 resulted in better angular resolution than 3T for depicting fibers crossing at shallow angles. Although the increased susceptibility effects at 7T caused problematic distortions near brain-air interfaces at the skull base and posterior fossa, these initial 7T QBI studies demonstrated excellent quality in much of the supratentorial brain with significant improvements as compared to 3T acquisitions in the same individuals. PMID:17692489
Lober, Robert M; Cho, Yoon-Jae; Tang, Yujie; Barnes, Patrick D; Edwards, Michael S; Vogel, Hannes; Fisher, Paul G; Monje, Michelle; Yeom, Kristen W
2014-03-01
While pediatric diffuse intrinsic pontine gliomas (DIPG) remain fatal, recent data have shown subgroups with distinct molecular biology and clinical behavior. We hypothesized that diffusion-weighted MRI can be used as a prognostic marker to stratify DIPG subsets with distinct clinical behavior. Apparent diffusion coefficient (ADC) values derived from diffusion-weighted MRI were computed in 20 consecutive children with treatment-naïve DIPG tumors. The median ADC for the cohort was used to stratify the tumors into low and high ADC groups. Survival, gender, therapy, and potential steroid effects were compared between the ADC groups. Median age at diagnosis was 6.6 (range 2.3-13.2) years, with median follow-up seven (range 1-36) months. There were 14 boys and six girls. Seventeen patients received radiotherapy, five received chemotherapy, and six underwent cerebrospinal fluid diversion. The median ADC of 1,295 × 10(-6) mm(2)/s for the cohort partitioned tumors into low or high diffusion groups, which had distinct median survivals of 3 and 13 months, respectively (log-rank p < 0.001). Low ADC tumors were found only in boys, whereas high ADC tumors were found in both boys and girls. Available tissue specimens in three low ADC tumors demonstrated high-grade histology, whereas one high ADC tumor demonstrated low-grade histology with a histone H3.1 K27M mutation and high-grade metastatic lesion at autopsy. ADC derived from diffusion-weighted MRI may identify prognostically distinct subgroups of pediatric DIPG.
Bickelhaupt, Sebastian; Tesdorff, Jana; Laun, Frederik Bernd; Kuder, Tristan Anselm; Lederer, Wolfgang; Teiner, Susanne; Maier-Hein, Klaus; Daniel, Heidi; Stieber, Anne; Delorme, Stefan; Schlemmer, Heinz-Peter
2017-02-01
The aim of this study was to evaluate the accuracy and applicability of solitarily reading fused image series of T2-weighted and high-b-value diffusion-weighted sequences for lesion characterization as compared to sequential or combined image analysis of these unenhanced sequences and to contrast- enhanced breast MRI. This IRB-approved study included 50 female participants with suspicious breast lesions detected in screening X-ray mammograms, all of which provided written informed consent. Prior to biopsy, all women underwent MRI including diffusion-weighted imaging (DWIBS, b = 1500s/mm 2 ). Images were analyzed as follows: prospective image fusion of DWIBS and T2-weighted images (FU), side-by-side analysis of DWIBS and T2-weighted series (CO), combination of the first two methods (CO+FU), and full contrast-enhanced diagnostic protocol (FDP). Diagnostic indices, confidence, and image quality of the protocols were compared by two blinded readers. Reading the CO+FU (accuracy 0.92; NPV 96.1 %; PPV 87.6 %) and the CO series (0.90; 96.1 %; 83.7 %) provided a diagnostic performance similar to the FDP (0.95; 96.1 %; 91.3 %; p > 0.05). FU reading alone significantly reduced the diagnostic accuracy (0.82; 93.3 %; 73.4 %; p = 0.023). MR evaluation of suspicious BI-RADS 4 and 5 lesions detected on mammography by using a non-contrast-enhanced T2-weighted and DWIBS sequence protocol is most accurate if MR images were read using the CO+FU protocol. • Unenhanced breast MRI with additional DWIBS/T2w-image fusion allows reliable lesion characterization. • Abbreviated reading of fused DWIBS/T2w-images alone decreases diagnostic confidence and accuracy. • Reading fused DWIBS/T2w-images as the sole diagnostic method should be avoided.
Lai, Vincent; Lee, Victor Ho Fun; Lam, Ka On; Sze, Henry Chun Kin; Chan, Queenie; Khong, Pek Lan
2015-06-01
To determine the utility of stretched exponential diffusion model in characterisation of the water diffusion heterogeneity in different tumour stages of nasopharyngeal carcinoma (NPC). Fifty patients with newly diagnosed NPC were prospectively recruited. Diffusion-weighted MR imaging was performed using five b values (0-2,500 s/mm(2)). Respective stretched exponential parameters (DDC, distributed diffusion coefficient; and alpha (α), water heterogeneity) were calculated. Patients were stratified into low and high tumour stage groups based on the American Joint Committee on Cancer (AJCC) staging for determination of the predictive powers of DDC and α using t test and ROC curve analyses. The mean ± standard deviation values were DDC = 0.692 ± 0.199 (×10(-3) mm(2)/s) for low stage group vs 0.794 ± 0.253 (×10(-3) mm(2)/s) for high stage group; α = 0.792 ± 0.145 for low stage group vs 0.698 ± 0.155 for high stage group. α was significantly lower in the high stage group while DDC was negatively correlated. DDC and α were both reliable independent predictors (p < 0.001), with α being more powerful. Optimal cut-off values were (sensitivity, specificity, positive likelihood ratio, negative likelihood ratio) DDC = 0.692 × 10(-3) mm(2)/s (94.4 %, 64.3 %, 2.64, 0.09), α = 0.720 (72.2 %, 100 %, -, 0.28). The heterogeneity index α is robust and can potentially help in staging and grading prediction in NPC. • Stretched exponential diffusion models can help in tissue characterisation in nasopharyngeal carcinoma • α and distributed diffusion coefficient (DDC) are negatively correlated • α is a robust heterogeneity index marker • α can potentially help in staging and grading prediction.
Ding, Jian-Rong; Wang, Dong-Nv; Pan, Jing-Li
2016-01-01
The present meta-analysis investigated the clinical value of apparent diffusion coefficient (ADC) values in diffusion-weighted imaging (DWI) for differential diagnosis of ductal carcinoma in situ (DCIS) and infiltrating ductal carcinoma (IDC). Electronic databases searches were employed to identify relevant scientific literature, and the search results were screened to selected high-quality studies for this meta-analysis. Methodological quality of the enrolled studies was evaluated by quality evaluation of diagnostic accuracy studies (QUADAS). Summary odds ratios (ORs) and its corresponding 95% confidence interval (95% CI) were calculated for DCIS versus IDC category of ADC value using Z test. Our meta-analysis contained a combined total of 1,097 subjects (928 patients with IDC and 169 patients with DCIS) from 9 relevant high-quality cohort studies. Pooled ORs demonstrated that ADC value in IDC patients was significantly lower than DCIS patients. Subgroup analysis stratified by ethnicity indicated a higher ADC value in DCIS patients compared to IDC, in Asian population, but not in Caucasians. Magnetic resonance imaging (MRI) machine type-stratified analysis revealed that the ADC value of DWI obtained from both non- General Electric Company (GE) 1.5T and GE 1.5T machines were highly reliable in the differential diagnosis of DCIS and IDC. Our meta-analysis provides evidence that ADC values in DWI accurately conveys the differences in tumor architecture between IDC and DCIS, which has high clinical value in differentiatal diagnosis of IDC and DCIS. This may lead to improved BC prediction and treatment.
Barral, M; Soyer, P; Ben Hassen, W; Gayat, E; Aout, M; Chiaradia, M; Rahmouni, A; Luciani, A
2013-04-01
To evaluate reproducibility and variations in apparent diffusion coefficient (ADC) measurement in normal pancreatic parenchyma at 1.5- and 3.0-Tesla and determine if differences may exist between the four pancreatic segments. Diffusion-weighted MR imaging of the pancreas was performed at 1.5-Tesla in 20 patients and at 3.0-Tesla in other 20 patients strictly matched for gender and age using the same b values (0, 400 and 800s/mm(2)). Two independent observers placed regions of interest within the four pancreatic segments to measure ADC at both fields. Intra- and inter-observer agreement in ADC measurement was assessed using Bland-Altman analysis and comparison between ADC values obtained at both fields using non-parametrical tests. There were no significant differences in ADC between repeated measurements and between ADC obtained at 1.5-Tesla and those at 3.0-Tesla. The 95% limits of intra-observer agreement between ADC were 2.3%-22.7% at 1.5-Tesla and 1%-24.2% at 3.0-Tesla and those for inter-observer agreement between 1.9%-14% at 1.5-Tesla and 8%-25% at 3.0-Tesla. ADC values were similar in all pancreatic segments at 3.0-T whereas the tail had lower ADC at 1.5-Tesla. ADC measurement conveys high degrees of intra- and inter-observer reproducibility. ADC have homogeneous distribution among the four pancreatic segments at 3.0-Tesla. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Mwangi, Benson; Wu, Mon-Ju; Bauer, Isabelle E; Modi, Haina; Zeni, Cristian P; Zunta-Soares, Giovana B; Hasan, Khader M; Soares, Jair C
2015-11-30
Previous studies have reported abnormalities of white-matter diffusivity in pediatric bipolar disorder. However, it has not been established whether these abnormalities are able to distinguish individual subjects with pediatric bipolar disorder from healthy controls with a high specificity and sensitivity. Diffusion-weighted imaging scans were acquired from 16 youths diagnosed with DSM-IV bipolar disorder and 16 demographically matched healthy controls. Regional white matter tissue microstructural measurements such as fractional anisotropy, axial diffusivity and radial diffusivity were computed using an atlas-based approach. These measurements were used to 'train' a support vector machine (SVM) algorithm to predict new or 'unseen' subjects' diagnostic labels. The SVM algorithm predicted individual subjects with specificity=87.5%, sensitivity=68.75%, accuracy=78.12%, positive predictive value=84.62%, negative predictive value=73.68%, area under receiver operating characteristic curve (AUROC)=0.7812 and chi-square p-value=0.0012. A pattern of reduced regional white matter fractional anisotropy was observed in pediatric bipolar disorder patients. These results suggest that atlas-based diffusion weighted imaging measurements can distinguish individual pediatric bipolar disorder patients from healthy controls. Notably, from a clinical perspective these findings will contribute to the pathophysiological understanding of pediatric bipolar disorder. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
An Exploration into Diffusion Tensor Imaging in the Bovine Ocular Lens
Vaghefi, Ehsan; Donaldson, Paul J.
2013-01-01
We describe our development of the diffusion tensor imaging modality for the bovine ocular lens. Diffusion gradients were added to a spin-echo pulse sequence and the relevant parameters of the sequence were refined to achieve good diffusion weighting in the lens tissue, which demonstrated heterogeneous regions of diffusive signal attenuation. Decay curves for b-value (loosely summarizes the strength of diffusion weighting) and TE (determines the amount of magnetic resonance imaging-obtained signal) were used to estimate apparent diffusion coefficients (ADC) and T2 in different lens regions. The ADCs varied by over an order of magnitude and revealed diffusive anisotropy in the lens. Up to 30 diffusion gradient directions, and 8 signal acquisition averages, were applied to lenses in culture in order to improve maps of diffusion tensor eigenvalues, equivalent to ADC, across the lens. From these maps, fractional anisotropy maps were calculated and compared to known spatial distributions of anisotropic molecular fluxes in the lens. This comparison suggested new hypotheses and experiments to quantitatively assess models of circulation in the avascular lens. PMID:23459990
Marcuzzo, Stefania; Bonanno, Silvia; Padelli, Francesco; Moreno-Manzano, Victoria; García-Verdugo, José Manuel; Bernasconi, Pia; Mantegazza, Renato; Bruzzone, Maria Grazia; Zucca, Ileana
2016-01-01
Diffusion-weighted Magnetic Resonance Imaging (dMRI) has relevant applications in the microstructural characterization of the spinal cord, especially in neurodegenerative diseases. Animal models have a pivotal role in the study of such diseases; however, in vivo spinal dMRI of small animals entails additional challenges that require a systematical investigation of acquisition parameters. The purpose of this study is to compare three acquisition protocols and identify the scanning parameters allowing a robust estimation of the main diffusion quantities and a good sensitivity to neurodegeneration in the mouse spinal cord. For all the protocols, the signal-to-noise and contrast-to noise ratios and the mean value and variability of Diffusion Tensor metrics were evaluated in healthy controls. For the estimation of fractional anisotropy less variability was provided by protocols with more diffusion directions, for the estimation of mean, axial and radial diffusivity by protocols with fewer diffusion directions and higher diffusion weighting. Intermediate features (12 directions, b = 1200 s/mm2) provided the overall minimum inter- and intra-subject variability in most cases. In order to test the diagnostic sensitivity of the protocols, 7 G93A-SOD1 mice (model of amyotrophic lateral sclerosis) at 10 and 17 weeks of age were scanned and the derived diffusion parameters compared with those estimated in age-matched healthy animals. The protocols with an intermediate or high number of diffusion directions provided the best differentiation between the two groups at week 17, whereas only few local significant differences were highlighted at week 10. According to our results, a dMRI protocol with an intermediate number of diffusion gradient directions and a relatively high diffusion weighting is optimal for spinal cord imaging. Further work is needed to confirm these results and for a finer tuning of acquisition parameters. Nevertheless, our findings could be important for the optimization of acquisition protocols for preclinical and clinical dMRI studies on the spinal cord. PMID:27560686
Huang, Jinbai; Luo, Jing; Peng, Jie; Yang, Tao; Zheng, Huanghua; Mao, Chunping
2017-11-01
Background Diffusion-weighted imaging (DWI) was introduced into clinical use some years ago. However, its use in the diagnosis of cerebral schistosomiasis has not been reported. Purpose To investigate the ability of the apparent diffusion coefficient (ADC) value of DWI in the diagnosis of cerebral schistosomiasis, and to differentiate it from brain high-grade gliomas and metastasis. Material and Methods Conventional brain MRI with pre-contrast, post-contrast, and DWI was performed on 50 cases of cerebral schistosomiasis, high-grade glioma, and brain metastasis. The ADC values of the three lesions, the proximal and the distal perifocal edema were measured. In order to remove the individual difference effect of ADC values, relative ADC (rADC) values were calculated through dividing the ADC value of the lesion area by that of the contralateral normal white matter. rADC values were used to evaluate the differences among cerebral schistosomiasis, brain high-grade gliomas, and metastasis. Results rADC of cerebral schistosomiasis was significantly lower than rADC of brain metastasis ( P < 0.05), without any significant differences when compared with high-grade gliomas. rADC of proximal perifocal edema in cerebral schistosomiasis was significantly higher than in high-grade gliomas ( P < 0.010), but not different compared with brain metastasis. Conclusion DWI examination with ADC values of lesions and proximal perifocal edema might be helpful in the exact diagnosis of cerebral schistosomiasis.
Steudle, Franziska; Paech, Daniel; Mlynarska, Anna; Kuder, Tristan Anselm; Lederer, Wolfgang; Daniel, Heidi; Freitag, Martin; Delorme, Stefan; Schlemmer, Heinz-Peter; Laun, Frederik Bernd
2017-01-01
Objective To evaluate a fractional order calculus (FROC) model in diffusion weighted imaging to differentiate between malignant and benign breast lesions in breast cancer screening work-up using recently introduced parameters (βFROC, DFROC and μFROC). Materials and methods This retrospective analysis within a prospective IRB-approved study included 51 participants (mean 58.4 years) after written informed consent. All patients had suspicious screening mammograms and indication for biopsy. Prior to biopsy, full diagnostic contrast-enhanced MRI examination was acquired including diffusion-weighted-imaging (DWI, b = 0,100,750,1500 s/mm2). Conventional apparent diffusion coefficient Dapp and FROC parameters (βFROC, DFROC and μFROC) as suggested further indicators of diffusivity components were measured in benign and malignant lesions. Receiver operating characteristics (ROC) were calculated to evaluate the diagnostic performance of the parameters. Results 29/51 patients histopathologically revealed malignant lesions. The analysis revealed an AUC for Dapp of 0.89 (95% CI 0.80–0.98). For FROC derived parameters, AUC was 0.75 (0.60–0.89) for DFROC, 0.59 (0.43–0.75) for βFROC and 0.59 (0.42–0.77) for μFROC. Comparison of the AUC curves revealed a significantly higher AUC of Dapp compared to the FROC parameters DFROC (p = 0.009), βFROC (p = 0.003) and μFROC (p = 0.001). Conclusion In contrast to recent description in brain tumors, the apparent diffusion coefficient Dapp showed a significantly higher AUC than the recently proposed FROC parameters βFROC, DFROC and μFROC for differentiating between malignant and benign breast lesions. This might be related to the intrinsic high heterogeneity within breast tissue or to the lower maximal b-value used in our study. PMID:28453516
Ashoor, Mansour; Khorshidi, Abdollah
2016-03-01
The goal of the present study was to estimate the number of compartments and the mean apparent diffusion coefficient (ADC) value with the use of the DWI signal curve. A useful new mathematic model that includes internal correlation among subcompartments with a distinct number of compartments was proposed. The DWI signal was simulated to estimate the approximate association between the number of subcompartments and the molecular density, with density corresponding to the ratio of the ADC values of the compartments, as determined using the Monte Carlo method. Various factors, such as energy depletion, temperature, intracellular water accumulation, changes in the tortuosity of the extracellular diffusion paths, and changes in cell membrane permeability, have all been implicated as factors contributing to changes in the ADC of water (ADCw); therefore, one may consider them as pseudocompartments in the new model proposed in this study. The lower the coefficient is, the lower the contribution of the compartment to the net signal will be. The results of the simulation indicate that when the number of compartments increases, the signal will become significantly lower, because the gradient factor (i.e., the b value) will increase. In other words, the signal curve is approximately linear at all b values when the number of compartments in which the tissues have been severely damaged is low; however, when the number of compartments is high, the curve will become constant at high b values, and the perfusion parameters will prevail on the diffusion parameters at low b values. Therefore, normal tissues will be investigated when the number of compartments and the ADC values are high and the b values are low, whereas damaged tissues will be evaluated when the number of compartments and the ADC values are low and the b values are high. The present study investigates damaged tissues at high b values for which the effect of eddy currents will also be compensated. These b values will probably be used in functional MRI.
Froeling, Martijn; Tax, Chantal M W; Vos, Sjoerd B; Luijten, Peter R; Leemans, Alexander
2017-05-01
In this work, we present the MASSIVE (Multiple Acquisitions for Standardization of Structural Imaging Validation and Evaluation) brain dataset of a single healthy subject, which is intended to facilitate diffusion MRI (dMRI) modeling and methodology development. MRI data of one healthy subject (female, 25 years) were acquired on a clinical 3 Tesla system (Philips Achieva) with an eight-channel head coil. In total, the subject was scanned on 18 different occasions with a total acquisition time of 22.5 h. The dMRI data were acquired with an isotropic resolution of 2.5 mm 3 and distributed over five shells with b-values up to 4000 s/mm 2 and two Cartesian grids with b-values up to 9000 s/mm 2 . The final dataset consists of 8000 dMRI volumes, corresponding B 0 field maps and noise maps for subsets of the dMRI scans, and ten three-dimensional FLAIR, T 1 -, and T 2 -weighted scans. The average signal-to-noise-ratio of the non-diffusion-weighted images was roughly 35. This unique set of in vivo MRI data will provide a robust framework to evaluate novel diffusion processing techniques and to reliably compare different approaches for diffusion modeling. The MASSIVE dataset is made publically available (both unprocessed and processed) on www.massive-data.org. Magn Reson Med 77:1797-1809, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Kang, Koung Mi; Choi, Seung Hong; Kim, Dong Eun; Yun, Tae Jin; Kim, Ji-Hoon; Sohn, Chul-Ho; Park, Sun-Won
2017-07-10
To prospectively evaluate whether cardiac gating can improve the reproducibility of intravoxel incoherent motion (IVIM) parameters in the head and neck, we performed IVIM diffusion-weighted imaging (DWI) using 4 b values (4b), 4 b values with cardiac gating (4b gating) and 17 b values (17b). We performed IVIM DWI twice per person on nine healthy volunteers using 4b, 4b gating and 17b and five patients with head and neck masses using 4b gating and 17b. The ADC, perfusion fraction (f), diffusion coefficient (D) and perfusion-related diffusion coefficient (D*) were calculated in the brain, masticator muscle, parotid gland, submandibular gland, tonsil and masses. Intraclass coefficient (ICC), Bland-Altman analysis (BAA) and coefficient of variation (CV) were used to assess short-term test-retest reproducibility. Kruskal-Wallis test and Mann-Whitney test were used to investigate whether 4b, 4b gating or 17b had significant influences on the parameters. For normal tissues and masses, ICC was excellent for all maps except the D* map. All parameters showed the lowest CV in the 4b gating. BAA also revealed the narrowest 95% limits of agreement using 4b gating for all parameters. In the subgroup analysis, almost all parameters in brain, muscle, parotid gland and submandibular gland showed the best reproducibility using 4b gating. In the muscle, parotid gland and submandibular gland, the values of ADC, f and D were not significantly different between among the three methods. 4b gating was more reproducible with respect to measurements of IVIM parameters in comparison with 4b or 17b.
Optimization of intra-voxel incoherent motion imaging at 3.0 Tesla for fast liver examination.
Leporq, Benjamin; Saint-Jalmes, Hervé; Rabrait, Cecile; Pilleul, Frank; Guillaud, Olivier; Dumortier, Jérôme; Scoazec, Jean-Yves; Beuf, Olivier
2015-05-01
Optimization of multi b-values MR protocol for fast intra-voxel incoherent motion imaging of the liver at 3.0 Tesla. A comparison of four different acquisition protocols were carried out based on estimated IVIM (DSlow , DFast , and f) and ADC-parameters in 25 healthy volunteers. The effects of respiratory gating compared with free breathing acquisition then diffusion gradient scheme (simultaneous or sequential) and finally use of weighted averaging for different b-values were assessed. An optimization study based on Cramer-Rao lower bound theory was then performed to minimize the number of b-values required for a suitable quantification. The duration-optimized protocol was evaluated on 12 patients with chronic liver diseases No significant differences of IVIM parameters were observed between the assessed protocols. Only four b-values (0, 12, 82, and 1310 s.mm(-2) ) were found mandatory to perform a suitable quantification of IVIM parameters. DSlow and DFast significantly decreased between nonadvanced and advanced fibrosis (P < 0.05 and P < 0.01) whereas perfusion fraction and ADC variations were not found to be significant. Results showed that IVIM could be performed in free breathing, with a weighted-averaging procedure, a simultaneous diffusion gradient scheme and only four optimized b-values (0, 10, 80, and 800) reducing scan duration by a factor of nine compared with a nonoptimized protocol. Preliminary results have shown that parameters such as DSlow and DFast based on optimized IVIM protocol can be relevant biomarkers to distinguish between nonadvanced and advanced fibrosis. © 2014 Wiley Periodicals, Inc.
Toslak, Iclal Erdem; Cekic, Bulent; Turk, Aysen; Eraslan, Ali; Parlak, A Eda
2017-10-10
Our aims were to determine the feasibility of diffusion-weighted magnetic resonance imaging (DWI) in the detection of bone marrow edema (BME) and explore the apparent diffusion coefficient (ADC) alterations in patients with osteitis pubis (OP). 42 consecutive patients clinically suspected to have athletic pubalgia and 31 control subjects were enrolled in the study. All subjects underwent diagnostic focused magnetic resonance imaging (MRI) and DWI at b values of 0 and 600 s/mm 2 . Two radiologists reviewed the images for the presence of active OP. The presence of subchondral BME and contrast enhancement were considered to indicate active OP. ADC values were measured from public bodies of both groups. DWI results were correlated with routine MRI findings. Receiver-operating-characteristic curves were formed. Cut-off values for ADC, sensitivity and specificity values were measured. 36/42 (85%) of the cases had BME/enhancement on routine MRIs and identified as active OP. ADC measurements of the patients were greater than the controls (P < 0.05). For the optimal cut-off values DWI showed sensitivity and specificity values of 97.3%, and 90.3%, for the right, and 97.1%, and 96.7% for the left side, respectively (Area under the curve 0.965 and 0.973). Intra-and inter-rater reliability for readers were substantial-perfect for all sessions. DWI is fast, accurate, and highly reproducible technique for the detection of BME in patients with active OP. It allows distinct bone marrow contrast without the use of gadolinium contrast, increases visual perception of active lesions, gives objective information by quantifying the diffusion coefficients, thus increase diagnostic confidence. We suggest the use of DWI as a cost-effective adjunctive tool for the diagnosis of active OP particularly in early cases and inconclusive diagnostic MRI. Future studies are necessary to determine the utility of DWI to evaluate severity of the disease and treatment response before returning athletes to play.
Park, Eun Kyung; Cho, Kyu Ran; Seo, Bo Kyoung; Woo, Ok Hee; Cho, Sung Bum; Bae, Jeoung Won
2016-01-01
Breast cancer is a heterogeneous disease with diverse prognoses. The main prognostic determinants are lymph node status, tumor size, histological grade, and biological factors, such as hormone receptors, human epidermal growth factor receptor 2 (HER2), Ki-67 protein levels, and p53 expression. Diffusion-weighted imaging (DWI) can be used to measure the apparent diffusion coefficient (ADC) that provides information related to tumor cellularity and the integrity of the cell membranes. The goal of this study was to evaluate whether ADC measurements could provide information on the prognostic factors of breast cancer. A total of 71 women with invasive breast cancer, treated consecutively, who underwent preoperative breast MRIs with DWI at 3.0 Tesla and subsequent surgery, were prospectively included in this study. Each DWI was acquired with b values of 0 and 1000 s/mm(2). The mean ADC values of the lesions were measured, including the entire lesion on the three largest sections. We performed histopathological analyses for the tumor size, lymph node status, histological grade, hormone receptors, human epidermal growth factor receptor 2 (HER2), Ki-67, p53, and molecular subtypes. The associations with the ADC values and prognostic factors of breast cancer were evaluated using the independent-samples t test and the one-way analysis of variance (ANOVA). A low ADC value was associated with lymph node metastasis (P < 0.01) and with high Ki-67 protein levels (P = 0.03). There were no significant differences in the ADC values among the histological grade (P = 0.48), molecular subtype (P = 0.51), tumor size (P = 0.46), and p53 protein level (P = 0.62). The pre-operative use of the 3.0 Tesla DWI could provide information about the lymph node status and tumor proliferation for breast cancer patients, and could help determine the optimal treatment plan.
Xu, Xiao Quan; Choi, Young Jun; Sung, Yu Sub; Yoon, Ra Gyoung; Jang, Seung Won; Park, Ji Eun; Heo, Young Jin; Baek, Jung Hwan; Lee, Jeong Hyun
2016-01-01
To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D(*)), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D(*) and model-free parameters from the DCE-MRI (wash-in, Tmax, Emax, initial AUC60, whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. No correlation was found between f or D(*) and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D(*) (p > 0.05, respectively). Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck.
Four-dimensional diffusion-weighted MR imaging (4D-DWI): a feasibility study.
Liu, Yilin; Zhong, Xiaodong; Czito, Brian G; Palta, Manisha; Bashir, Mustafa R; Dale, Brian M; Yin, Fang-Fang; Cai, Jing
2017-02-01
Diffusion-weighted Magnetic Resonance Imaging (DWI) has been shown to be a powerful tool for cancer detection with high tumor-to-tissue contrast. This study aims to investigate the feasibility of developing a four-dimensional DWI technique (4D-DWI) for imaging respiratory motion for radiation therapy applications. Image acquisition was performed by repeatedly imaging a volume of interest (VOI) using an interleaved multislice single-shot echo-planar imaging (EPI) 2D-DWI sequence in the axial plane. Each 2D-DWI image was acquired with an intermediately low b-value (b = 500 s/mm 2 ) and with diffusion-encoding gradients in x, y, and z diffusion directions. Respiratory motion was simultaneously recorded using a respiratory bellow, and the synchronized respiratory signal was used to retrospectively sort the 2D images to generate 4D-DWI. Cine MRI using steady-state free precession was also acquired as a motion reference. As a preliminary feasibility study, this technique was implemented on a 4D digital human phantom (XCAT) with a simulated pancreas tumor. The respiratory motion of the phantom was controlled by regular sinusoidal motion profile. 4D-DWI tumor motion trajectories were extracted and compared with the input breathing curve. The mean absolute amplitude differences (D) were calculated in superior-inferior (SI) direction and anterior-posterior (AP) direction. The technique was then evaluated on two healthy volunteers. Finally, the effects of 4D-DWI on apparent diffusion coefficient (ADC) measurements were investigated for hypothetical heterogeneous tumors via simulations. Tumor trajectories extracted from XCAT 4D-DWI were consistent with the input signal: the average D value was 1.9 mm (SI) and 0.4 mm (AP). The average D value was 2.6 mm (SI) and 1.7 mm (AP) for the two healthy volunteers. A 4D-DWI technique has been developed and evaluated on digital phantom and human subjects. 4D-DWI can lead to more accurate respiratory motion measurement. This has a great potential to improve the visualization and delineation of cancer tumors for radiotherapy. © 2016 American Association of Physicists in Medicine.
High-throughput ab-initio dilute solute diffusion database.
Wu, Henry; Mayeshiba, Tam; Morgan, Dane
2016-07-19
We demonstrate automated generation of diffusion databases from high-throughput density functional theory (DFT) calculations. A total of more than 230 dilute solute diffusion systems in Mg, Al, Cu, Ni, Pd, and Pt host lattices have been determined using multi-frequency diffusion models. We apply a correction method for solute diffusion in alloys using experimental and simulated values of host self-diffusivity. We find good agreement with experimental solute diffusion data, obtaining a weighted activation barrier RMS error of 0.176 eV when excluding magnetic solutes in non-magnetic alloys. The compiled database is the largest collection of consistently calculated ab-initio solute diffusion data in the world.
In vivo High Angular Resolution Diffusion-Weighted Imaging of Mouse Brain at 16.4 Tesla
Alomair, Othman I.; Brereton, Ian M.; Smith, Maree T.; Galloway, Graham J.; Kurniawan, Nyoman D.
2015-01-01
Magnetic Resonance Imaging (MRI) of the rodent brain at ultra-high magnetic fields (> 9.4 Tesla) offers a higher signal-to-noise ratio that can be exploited to reduce image acquisition time or provide higher spatial resolution. However, significant challenges are presented due to a combination of longer T 1 and shorter T 2/T2* relaxation times and increased sensitivity to magnetic susceptibility resulting in severe local-field inhomogeneity artefacts from air pockets and bone/brain interfaces. The Stejskal-Tanner spin echo diffusion-weighted imaging (DWI) sequence is often used in high-field rodent brain MRI due to its immunity to these artefacts. To accurately determine diffusion-tensor or fibre-orientation distribution, high angular resolution diffusion imaging (HARDI) with strong diffusion weighting (b >3000 s/mm2) and at least 30 diffusion-encoding directions are required. However, this results in long image acquisition times unsuitable for live animal imaging. In this study, we describe the optimization of HARDI acquisition parameters at 16.4T using a Stejskal-Tanner sequence with echo-planar imaging (EPI) readout. EPI segmentation and partial Fourier encoding acceleration were applied to reduce the echo time (TE), thereby minimizing signal decay and distortion artefacts while maintaining a reasonably short acquisition time. The final HARDI acquisition protocol was achieved with the following parameters: 4 shot EPI, b = 3000 s/mm2, 64 diffusion-encoding directions, 125×150 μm2 in-plane resolution, 0.6 mm slice thickness, and 2h acquisition time. This protocol was used to image a cohort of adult C57BL/6 male mice, whereby the quality of the acquired data was assessed and diffusion tensor imaging (DTI) derived parameters were measured. High-quality images with high spatial and angular resolution, low distortion and low variability in DTI-derived parameters were obtained, indicating that EPI-DWI is feasible at 16.4T to study animal models of white matter (WM) diseases. PMID:26110770
Barbaro, Brunella; Vitale, Renata; Valentini, Vincenzo; Illuminati, Sonia; Vecchio, Fabio M; Rizzo, Gianluca; Gambacorta, Maria Antonietta; Coco, Claudio; Crucitti, Antonio; Persiani, Roberto; Sofo, Luigi; Bonomo, Lorenzo
2012-06-01
To prospectively monitor the response in patients with locally advanced nonmucinous rectal cancer after chemoradiotherapy (CRT) using diffusion-weighted magnetic resonance imaging. The histopathologic finding was the reference standard. The institutional review board approved the present study. A total of 62 patients (43 men and 19 women; mean age, 64 years; range, 28-83) provided informed consent. T(2)- and diffusion-weighted magnetic resonance imaging scans (b value, 0 and 1,000 mm(2)/s) were acquired before, during (mean 12 days), and 6-8 weeks after CRT. We compared the median apparent diffusion coefficients (ADCs) between responders and nonresponders and examined the associations with the Mandard tumor regression grade (TRG). The postoperative nodal status (ypN) was evaluated. The Mann-Whitney/Wilcoxon two-sample test was used to evaluate the relationships among the pretherapy ADCs, extramural vascular invasion, early percentage of increases in ADCs, and preoperative ADCs. Low pretreatment ADCs (<1.0 × 10(-3)mm(2)/s) were correlated with TRG 4 scores (p = .0011) and associated to extramural vascular invasion with ypN+ (85.7% positive predictive value for ypN+). During treatment, the mean percentage of increase in tumor ADC was significantly greater in the responders than in the nonresponders (p < .0001) and a >23% ADC increase had a 96.3% negative predictive value for TRG 4. In 9 of 16 complete responders, CRT-related tumor downsizing prevented ADC evaluations. The preoperative ADCs were significantly different (p = .0012) between the patients with and without downstaging (preoperative ADC ≥1.4 × 10(-3)mm(2)/s showed a positive and negative predictive value of 78.9% and 61.8%, respectively, for response assessment). The TRG 1 and TRG 2-4 groups were not significantly different. Diffusion-weighted magnetic resonance imaging seems to be a promising tool for monitoring the response to CRT. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barbaro, Brunella, E-mail: bbarbaro@rm.unicatt.it; Vitale, Renata; Valentini, Vincenzo
2012-06-01
Purpose: To prospectively monitor the response in patients with locally advanced nonmucinous rectal cancer after chemoradiotherapy (CRT) using diffusion-weighted magnetic resonance imaging. The histopathologic finding was the reference standard. Methods and Materials: The institutional review board approved the present study. A total of 62 patients (43 men and 19 women; mean age, 64 years; range, 28-83) provided informed consent. T{sub 2}- and diffusion-weighted magnetic resonance imaging scans (b value, 0 and 1,000 mm{sup 2}/s) were acquired before, during (mean 12 days), and 6-8 weeks after CRT. We compared the median apparent diffusion coefficients (ADCs) between responders and nonresponders and examinedmore » the associations with the Mandard tumor regression grade (TRG). The postoperative nodal status (ypN) was evaluated. The Mann-Whitney/Wilcoxon two-sample test was used to evaluate the relationships among the pretherapy ADCs, extramural vascular invasion, early percentage of increases in ADCs, and preoperative ADCs. Results: Low pretreatment ADCs (<1.0 Multiplication-Sign 10{sup -3}mm{sup 2}/s) were correlated with TRG 4 scores (p = .0011) and associated to extramural vascular invasion with ypN+ (85.7% positive predictive value for ypN+). During treatment, the mean percentage of increase in tumor ADC was significantly greater in the responders than in the nonresponders (p < .0001) and a >23% ADC increase had a 96.3% negative predictive value for TRG 4. In 9 of 16 complete responders, CRT-related tumor downsizing prevented ADC evaluations. The preoperative ADCs were significantly different (p = .0012) between the patients with and without downstaging (preoperative ADC {>=}1.4 Multiplication-Sign 10{sup -3}mm{sup 2}/s showed a positive and negative predictive value of 78.9% and 61.8%, respectively, for response assessment). The TRG 1 and TRG 2-4 groups were not significantly different. Conclusion: Diffusion-weighted magnetic resonance imaging seems to be a promising tool for monitoring the response to CRT.« less
Bastin, M E; Armitage, P A
2000-07-01
The accurate determination of absolute measures of diffusion anisotropy in vivo using single-shot, echo-planar imaging techniques requires the acquisition of a set of high signal-to-noise ratio, diffusion-weighted images that are free from eddy current induced image distortions. Such geometric distortions can be characterized and corrected in brain imaging data using magnification (M), translation (T), and shear (S) distortion parameters derived from separate water phantom calibration experiments. Here we examine the practicalities of using separate phantom calibration data to correct high b-value diffusion tensor imaging data by investigating the stability of these distortion parameters, and hence the eddy currents, with time. It is found that M, T, and S vary only slowly with time (i.e., on the order of weeks), so that calibration scans need not be performed after every patient examination. This not only minimises the scan time required to collect the calibration data, but also the computational time needed to characterize these eddy current induced distortions. Examples of how measurements of diffusion anisotropy are improved using this post-processing scheme are also presented.
van den Bos, Indra C; Hussain, Shahid M; Krestin, Gabriel P; Wielopolski, Piotr A
2008-07-01
Institutional Review Board approval and signed informed consent were obtained by all participants for an ongoing sequence optimization project at 3.0 T. The purpose of this study was to evaluate breath-hold diffusion-induced black-blood echo-planar imaging (BBEPI) as a potential alternative for specific absorption rate (SAR)-intensive spin-echo sequences, in particular, the fast spin-echo (FSE) sequences, at 3.0 T. Fourteen healthy volunteers (seven men, seven women; mean age +/- standard deviation, 32.7 years +/- 6.8) were imaged for this purpose. Liver coverage (20 cm, z-axis) was always performed in one 25-second breath hold. Imaging parameters were varied interactively with regard to echo time, diffusion b value, and voxel size. Images were evaluated and compared with fat-suppressed T2-weighted FSE images for image quality, liver delineation, geometric distortions, fat suppression, suppression of the blood signal, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). An optimized short- (25 msec) and long-echo (80 msec) BBEPI provided full anatomic, single breath-hold liver coverage (100 and 50 sections, respectively), with resulting voxel sizes of 3.3 x 2.7 x 2.0 mm and 3.3 x 2.7 x 4.0 mm, respectively. Repetition time was 6300 msec, matrix size was 160 x 192, and an acceleration factor of 2.00 was used. b Values of more than 20 sec/mm(2) showed better suppression of the blood signal but b values of 10 sec/mm(2) provided improved volume coverage and signal consistency. Compared with fat-suppressed T2-weighted FSE, the optimized BBEPI sequence provided (a) comparable image quality and liver delineation, (b) acceptable geometric distortions, (c) improved suppression of fat and blood signals, and (d) high CNR and SNR. BBEPI is feasible for fast, low-SAR, thin-section morphologic imaging of the entire liver in a single breath hold at 3.0 T. (c) RSNA, 2008.
Kwon, Oh-Hun; Park, Hyunjin; Seo, Sang-Won; Na, Duk L.; Lee, Jong-Min
2015-01-01
The mean diffusivity (MD) value has been used to describe microstructural properties in Diffusion Tensor Imaging (DTI) in cortical gray matter (GM). Recently, researchers have applied a cortical surface generated from the T1-weighted volume. When the DTI data are analyzed using the cortical surface, it is important to assign an accurate MD value from the volume space to the vertex of the cortical surface, considering the anatomical correspondence between the DTI and the T1-weighted image. Previous studies usually sampled the MD value using the nearest-neighbor (NN) method or Linear method, even though there are geometric distortions in diffusion-weighted volumes. Here we introduce a Surface Guided Diffusion Mapping (SGDM) method to compensate for such geometric distortions. We compared our SGDM method with results using NN and Linear methods by investigating differences in the sampled MD value. We also projected the tissue classification results of non-diffusion-weighted volumes to the cortical midsurface. The CSF probability values provided by the SGDM method were lower than those produced by the NN and Linear methods. The MD values provided by the NN and Linear methods were significantly greater than those of the SGDM method in regions suffering from geometric distortion. These results indicate that the NN and Linear methods assigned the MD value in the CSF region to the cortical midsurface (GM region). Our results suggest that the SGDM method is an effective way to correct such mapping errors. PMID:26236180
NASA Astrophysics Data System (ADS)
Mahmood, Faisal; Johannesen, Helle H.; Geertsen, Poul; Hansen, Rasmus H.
2017-04-01
An imaging biomarker for early prediction of treatment response potentially provides a non-invasive tool for better prognostics and individualized management of the disease. Radiotherapy (RT) response is generally related to changes in gross tumor volume manifesting months later. In this prospective study we investigated the apparent diffusion coefficient (ADC), perfusion fraction and pseudo diffusion coefficient derived from diffusion weighted MRI as potential early biomarkers for radiotherapy response of brain metastases. It was a particular aim to assess the optimal time point for acquiring the DW-MRI scan during the course of treatment, since to our knowledge this important question has not been addressed directly in previous studies. Twenty-nine metastases (N = 29) from twenty-one patients, treated with whole-brain fractionated external beam RT were analyzed. Patients were scanned with a 1 T MRI system to acquire DW-, T2*W-, T2W- and T1W scans, before start of RT, at each fraction and at follow up two to three months after RT. The DW-MRI parameters were derived using regions of interest based on high b-value images (b = 800 s mm-2). Both volumetric and RECIST criteria were applied for response evaluation. It was found that in non-responding metastases the mean ADC decreased and in responding metastases it increased. The volume based response proved to be far more consistently predictable by the ADC change found at fraction number 7 and later, compared to the linear response (RECIST). The perfusion fraction and pseudo diffusion coefficient did not show sufficient prognostic value with either response assessment criteria. In conclusion this study shows that the ADC derived using high b-values may be a reliable biomarker for early assessment of radiotherapy response for brain metastases patients. The earliest response stratification can be achieved using two DW-MRI scans, one pre-treatment and one at treatment day 7-9 (equivalent to 21 Gy).
Ligneul, Clémence; Palombo, Marco; Valette, Julien
2017-04-01
To assess the potential correlation between metabolites diffusion and relaxation in the mouse brain, which is of importance for interpreting and modeling metabolite diffusion based on pure geometry, irrespective of relaxation properties (multicompartmental relaxation or surface relaxivity). A new diffusion-weighted magnetic resonance spectroscopy sequence is introduced, dubbed "STE-LASER," which presents several nice properties, in particular the absence of cross-terms with selection gradients and a very clean localization. Metabolite diffusion is then measured in a large voxel in the mouse brain at 11.7 Tesla using a cryoprobe, resulting in excellent signal-to-noise ratio, up to very high b-values under different echo time, mixing time, and diffusion time combinations. Our results suggest that the correlation between relaxation and diffusion properties is extremely small or even nonexistent for metabolites in the mouse brain. The present work strongly supports the interpretation and modeling of metabolite diffusion primarily based on geometry, irrespective of relaxation properties, at least under current experimental conditions. Magn Reson Med 77:1390-1398, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Balch, J; Guéguen, C
2015-01-01
In situ measurements of labile metal species using diffusive gradients in thin films (DGT) passive samplers are based on the diffusion rates of individual species. Although most studies have dealt with chemically isolated humic substances, the diffusion of dissolved organic matter (DOM) across the hydrogel is not well understood. In this study, the diffusion coefficient (D) and molecular weight (MW) of 11 aquatic DOM and 4 humic substances (HS) were determined. Natural, unaltered aquatic DOM was capable of diffusing across the diffusive gel membrane with D values ranging from 2.48×10(-6) to 5.31×10(-6) cm(2) s(-1). Humic substances had diffusion coefficient values ranging from 3.48×10(-6) to 6.05×10(-6) cm(2) s(-1), congruent with previous studies. Molecular weight of aquatic DOM and HS samples (∼500-1750 Da) measured using asymmetrical flow field-flow fractionation (AF4) strongly influenced D, with larger molecular weight DOM having lower D values. No noticeable changes in DOM size properties were observed during the diffusion process, suggesting that DOM remains intact following diffusion across the diffusive gel. The influence of molecular weight on DOM mobility will assist in further understanding and development of the DGT technique and the uptake and mobility of contaminants associated with DOM in aquatic environments. Copyright © 2014 Elsevier Ltd. All rights reserved.
Assessment of Activity of Crohn Disease by Diffusion-Weighted Magnetic Resonance Imaging
Li, Xue-hua; Sun, Can-hui; Mao, Ren; Zhang, Zhong-wei; Jiang, Xiao-song; Pui, Margaret H.; Chen, Min-hu; Li, Zi-ping
2015-01-01
Abstract To assess the diagnostic efficacy of diffusion-weighted MR imaging (DWI) for evaluating inflammatory activity in patients with Crohn's disease (CD). A total of 47 CD patients underwent MR enterography (MRE) and DWI using 3 b values of 50, 400, and 800 s/mm.2 Apparent diffusion coefficients (ADCs) of inflamed and normal bowel wall were calculated. The conventional MRE findings and DWI signal intensities were qualitatively scored from 0 to 3. The correlation between Crohn disease activity index (CDAI) and both ADCs and magnetic resonance imaging scores was analyzed. Receiver-operating characteristic curve analysis was used to determine the diagnostic accuracy of CD activity. Of the 47 patients, 25 were active CD (CDAI≥150) and 22 were inactive (CDAI<150). Diffusion-weighted MR imaging and MRE + DWI scores of active CD were significantly higher than that of inactive CD (both P < 0.001). Apparent diffusion coefficients in inflamed segments of active CD were lower than that of inactive CD (P < 0.001). The DWI scores (r = 0.74, P < 0.001), ADCs (r = −0.71, P < 0.001), MRE scores (r = 0.54, P < 0.001), and MRE + DWI scores (r = 0.66, P < 0.001) were all correlated with CDAI. The areas under the receiver-operating characteristics curves for ADCs, DWI scores, MRE scores, and MRE + DWI scores ranged from 0.83 to 0.98. The threshold ADC value of 1.17 × 10−3 mm2/s allowed differentiation of active from inactive CD with 100% sensitivity and 88% specificity. Diffusion-weighted MR imaging and ADC correlated with CD activity, and had excellent diagnostic accuracy for differentiating active from inactive CD. PMID:26512584
Kothari, Shweta; Singh, Archana; Das, Utpalendu; Sarkar, Diptendra K; Datta, Chhanda; Hazra, Avijit
2017-01-01
Objective: To evaluate the role of exponential apparent diffusion coefficient (ADC) as a tool for differentiating benign and malignant breast lesions. Patients and Methods: This prospective observational study included 88 breast lesions in 77 patients (between 18 and 85 years of age) who underwent 3T breast magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) using b-values of 0 and 800 s/mm2 before biopsy. Mean exponential ADC and ADC of benign and malignant lesions obtained from DWI were compared. Receiver operating characteristics (ROC) curve analysis was undertaken to identify any cut-off for exponential ADC and ADC to predict malignancy. P value of <0.05 was considered statistically significant. Histopathology was taken as the gold standard. Results: According to histopathology, 65 lesions were malignant and 23 were benign. The mean ADC and exponential ADC values of malignant lesions were 0.9526 ± 0.203 × 10−3 mm2/s and 0.4774 ± 0.071, respectively, and for benign lesions were 1.48 ± 0.4903 × 10−3 mm2/s and 0.317 ± 0.1152, respectively. For both the parameters, differences were highly significant (P < 0.001). Cut-off value of ≤0.0011 mm2/s (P < 0.0001) for ADC provided 92.3% sensitivity and 73.9% specificity, whereas with an exponential ADC cut-off value of >0.4 (P < 0.0001) for malignant lesions, 93.9% sensitivity and 82.6% specificity was obtained. The performance of ADC and exponential ADC in distinguishing benign and malignant breast lesions based on respective cut-offs was comparable (P = 0.109). Conclusion: Exponential ADC can be used as a quantitative adjunct tool for characterizing breast lesions with comparable sensitivity and specificity as that of ADC. PMID:28744085
Xiong, Hui; Zeng, Yuan-Lin
2016-01-01
We sought to determine the comparative diagnostic performance of standard-b-value (500-1000s/mm) versus low-b-value (≤500 s/mm) diffusion-weighted imaging (DWI) in the discrimination of hepatic lesions. A total of 1775 hepatic malignant lesions and 1120 benign hepatic lesions from 21 studies were included. (1) The global sensitivity was 0.86 (95% confidence interval [CI], 0.847-0.879), the specificity was 0.82 (95% CI, 0.797-0.842), the positive likelihood ratio (PLR) was 6.234 (95% CI, 4.260-9.123), the negative likelihood ratio (NLR) was 0.175 (95% CI, 0.135-0.227), and diagnostic odds ratio (DOR) was 42.836 (95% CI, 24.134-76.031). The area under the curve (AUC) and Q* index were 0.93 and 0.87. Publication bias was not present (P > 0.05). (2)The sensitivity of a subgroup meta-analysis of standard-b-value DWI was 0.858 (95% CI, 0.835-0.880), the specificity was 0.836 (95% CI, 0.807-0.863), the PLR was 6.527 (95% CI, 3.857-11.046), the NLR was 0.168 (95% CI, 0.123-0.239), and the DOR was 49.716 (95% CI, 22.897-107.98). The AUC and Q* index were 0.941 and 0.88. (3)The sensitivity of a subgroup meta-analysis of low-b-value DWI was 0.87 (95% CI, 0.84-0.89), the specificity was 0.80 (95% CI, 0.76-0.83), the PLR was 6.22 (95% CI, 3.29-11.76), the NLR was 0.19 (95% CI, 0.12-0.29), and the DOR was 37.14 (95% CI, 14.80-93.18). The AUC and Q* index were 0.922 and 0.86. Hepatic DWI is useful in differentiating between malignant and benign hepatic lesions. Standard-b-value DWI displayed an overall superior diagnostic accuracy over low-b-value DWI. Further trials needed to determine whether increasing b values beyond 1000 s/mm affects the diagnostic accuracy of hepatic lesion discrimination.
Duarte-Carvajalino, Julio M.; Sapiro, Guillermo; Harel, Noam; Lenglet, Christophe
2013-01-01
Registration of diffusion-weighted magnetic resonance images (DW-MRIs) is a key step for population studies, or construction of brain atlases, among other important tasks. Given the high dimensionality of the data, registration is usually performed by relying on scalar representative images, such as the fractional anisotropy (FA) and non-diffusion-weighted (b0) images, thereby ignoring much of the directional information conveyed by DW-MR datasets itself. Alternatively, model-based registration algorithms have been proposed to exploit information on the preferred fiber orientation(s) at each voxel. Models such as the diffusion tensor or orientation distribution function (ODF) have been used for this purpose. Tensor-based registration methods rely on a model that does not completely capture the information contained in DW-MRIs, and largely depends on the accurate estimation of tensors. ODF-based approaches are more recent and computationally challenging, but also better describe complex fiber configurations thereby potentially improving the accuracy of DW-MRI registration. A new algorithm based on angular interpolation of the diffusion-weighted volumes was proposed for affine registration, and does not rely on any specific local diffusion model. In this work, we first extensively compare the performance of registration algorithms based on (i) angular interpolation, (ii) non-diffusion-weighted scalar volume (b0), and (iii) diffusion tensor image (DTI). Moreover, we generalize the concept of angular interpolation (AI) to non-linear image registration, and implement it in the FMRIB Software Library (FSL). We demonstrate that AI registration of DW-MRIs is a powerful alternative to volume and tensor-based approaches. In particular, we show that AI improves the registration accuracy in many cases over existing state-of-the-art algorithms, while providing registered raw DW-MRI data, which can be used for any subsequent analysis. PMID:23596381
Duarte-Carvajalino, Julio M; Sapiro, Guillermo; Harel, Noam; Lenglet, Christophe
2013-01-01
Registration of diffusion-weighted magnetic resonance images (DW-MRIs) is a key step for population studies, or construction of brain atlases, among other important tasks. Given the high dimensionality of the data, registration is usually performed by relying on scalar representative images, such as the fractional anisotropy (FA) and non-diffusion-weighted (b0) images, thereby ignoring much of the directional information conveyed by DW-MR datasets itself. Alternatively, model-based registration algorithms have been proposed to exploit information on the preferred fiber orientation(s) at each voxel. Models such as the diffusion tensor or orientation distribution function (ODF) have been used for this purpose. Tensor-based registration methods rely on a model that does not completely capture the information contained in DW-MRIs, and largely depends on the accurate estimation of tensors. ODF-based approaches are more recent and computationally challenging, but also better describe complex fiber configurations thereby potentially improving the accuracy of DW-MRI registration. A new algorithm based on angular interpolation of the diffusion-weighted volumes was proposed for affine registration, and does not rely on any specific local diffusion model. In this work, we first extensively compare the performance of registration algorithms based on (i) angular interpolation, (ii) non-diffusion-weighted scalar volume (b0), and (iii) diffusion tensor image (DTI). Moreover, we generalize the concept of angular interpolation (AI) to non-linear image registration, and implement it in the FMRIB Software Library (FSL). We demonstrate that AI registration of DW-MRIs is a powerful alternative to volume and tensor-based approaches. In particular, we show that AI improves the registration accuracy in many cases over existing state-of-the-art algorithms, while providing registered raw DW-MRI data, which can be used for any subsequent analysis.
Vallini, Valentina; Ortori, Simona; Boraschi, Piero; Manassero, Francesca; Gabelloni, Michela; Faggioni, Lorenzo; Selli, Cesare; Bartolozzi, Carlo
2016-01-01
To evaluate the usefulness of diffusion-weighted imaging (DWI) with a multiple b value SE-EPI sequence on a 3.0 T MR scanner for staging of pelvic lymph nodes in patients with prostate cancer candidate to radical prostatectomy and extended pelvic lymph node dissection (PLND). Institutional review board approval was obtained and written informed consent was taken from all enrolled subjects. A series of 26 patients with pathologically proven prostate cancer (high or intermediate risk according to D'Amico risk groups) scheduled for radical prostatectomy and PLND underwent 3 T MRI before surgery. DWI was performed using an axial respiratory-triggered spin-echo echo-planar sequence with multiple b values (500, 800, 1000, 1500 s/mm(2)) in all diffusion directions. ADC values were calculated by means of dedicated software fitting the curve obtained from the corresponding ADC for each b value. Fitted ADC measurements were performed at the level of proximal and distal external iliac, internal iliac, and obturator nodal stations bilaterally. Lymph node appearance was also assessed in terms of short axis, long-to-short axis ratio, node contour and intranodal heterogeneity of signal intensity. A total of 173 lymph nodes and 104 nodal stations were evaluated on DWI and pathologically analysed. Mean fitted ADC values were 0.79 ± 0.14 × 10(-3) mm(2)/s for metastatic lymph nodes and 1.13 ± 0.29 × 10(-3) mm(2)/s in non-metastatic ones (P < 0.0001). The cut-off for fitted ADC obtained by ROC curve analysis was 0.91 × 10(-3) mm(2)/s. A two-point-level score was assigned for each qualitative parameter, and the mean grading score was 6.09 ± 0.61 for metastastic lymph nodes and 5.42 ± 0.79 for non-metastatic ones, respectively (P = 0.001). Using a score threshold of 4 for morphological, structural, and dimensional MRI analysis and a cut--off value of 0.91 × 10(-3) mm(2)/s for fitted ADC measurements of pelvic lymph nodes, per--station sensitivity, specificity, PPV, NPV and diagnostic accuracy were 100%, 7.9%, 15.6%, 100% and 21.3%, and 84.6%, 89.5%, 57.9%, 97.1% and 88.8%, respectively. 3.0T DWI with a multiple b value SE-EPI sequence may help distinguish benign from malignant pelvic lymph nodes in patients with prostate cancer.
High-throughput ab-initio dilute solute diffusion database
Wu, Henry; Mayeshiba, Tam; Morgan, Dane
2016-01-01
We demonstrate automated generation of diffusion databases from high-throughput density functional theory (DFT) calculations. A total of more than 230 dilute solute diffusion systems in Mg, Al, Cu, Ni, Pd, and Pt host lattices have been determined using multi-frequency diffusion models. We apply a correction method for solute diffusion in alloys using experimental and simulated values of host self-diffusivity. We find good agreement with experimental solute diffusion data, obtaining a weighted activation barrier RMS error of 0.176 eV when excluding magnetic solutes in non-magnetic alloys. The compiled database is the largest collection of consistently calculated ab-initio solute diffusion data in the world. PMID:27434308
Yang, Yunjun; Gao, Lingyun; Fu, Jun; Zhang, Jun; Li, Yuxin; Yin, Bo; Chen, Weijian; Geng, Daoying
2013-01-01
Supratentorial cerebral infarction can cause functional inhibition of remote regions such as the cerebellum, which may be relevant to diaschisis. This phenomenon is often analyzed using positron emission tomography and single photon emission CT. However, these methods are expensive and radioactive. Thus, the present study quantified the changes of infarction core and remote regions after unilateral middle cerebral artery occlusion using apparent diffusion coefficient values. Diffusion-weighted imaging showed that the area of infarction core gradually increased to involve the cerebral cortex with increasing infarction time. Diffusion weighted imaging signals were initially increased and then stabilized by 24 hours. With increasing infarction time, the apparent diffusion coefficient value in the infarction core and remote bilateral cerebellum both gradually decreased, and then slightly increased 3–24 hours after infarction. Apparent diffusion coefficient values at remote regions (cerebellum) varied along with the change of supratentorial infarction core, suggesting that the phenomenon of diaschisis existed at the remote regions. Thus, apparent diffusion coefficient values and diffusion weighted imaging can be used to detect early diaschisis. PMID:25206615
Effects of motion and b-matrix correction for high resolution DTI with short-axis PROPELLER-EPI
Aksoy, Murat; Skare, Stefan; Holdsworth, Samantha; Bammer, Roland
2010-01-01
Short-axis PROPELLER-EPI (SAP-EPI) has been proven to be very effective in providing high-resolution diffusion-weighted and diffusion tensor data. The self-navigation capabilities of SAP-EPI allow one to correct for motion, phase errors, and geometric distortion. However, in the presence of patient motion, the change in the effective diffusion-encoding direction (i.e. the b-matrix) between successive PROPELLER ‘blades’ can decrease the accuracy of the estimated diffusion tensors, which might result in erroneous reconstruction of white matter tracts in the brain. In this study, we investigate the effects of alterations in the b-matrix as a result of patient motion on the example of SAP-EPI DTI and eliminate these effects by incorporating our novel single-step non-linear diffusion tensor estimation scheme into the SAP-EPI post-processing procedure. Our simulations and in-vivo studies showed that, in the presence of patient motion, correcting the b-matrix is necessary in order to get more accurate diffusion tensor and white matter pathway reconstructions. PMID:20222149
Bickel, Hubert; Pinker-Domenig, Katja; Bogner, Wolfgang; Spick, Claudio; Bagó-Horváth, Zsuzsanna; Weber, Michael; Helbich, Thomas; Baltzer, Pascal
2015-02-01
The objective of this study was to evaluate whether apparent diffusion coefficient (ADC) obtained through diffusion-weighted imaging magnetic resonance imaging at 3 T can be used as an imaging biomarker to differentiate invasive breast cancer from noninvasive ductal carcinoma in situ (DCIS). One hundred seventy-six histopathologically verified primary malignant breast tumors were retrospectively evaluated in 170 patients. All patients had undergone a standardized 3-T magnetic resonance imaging protocol, containing a diffusion-weighted sequence with 2 b values and a series of dynamic contrast-enhanced T1-weighted sequences. Apparent diffusion coefficient was measured manually by a reader blinded to the histopathological results. The ADC values were correlated with histopathological results. Mean ADC values were compared between invasive cancers and DCIS as well as between different tumor grades. Receiver operating characteristics curves were used to calculate diagnostic performance. There were 155 invasive cancers and 21 noninvasive DCIS. Mean (SD) values differed significantly between the invasive cancers (0.9 [0.15] ×10 mm/s) and the DCIS (1.24 [0.23] ×10 mm/s, P < 0.001). Area under the receiver operating characteristics curve was 0.895 (95% confidence interval [CI], 0.840-0.936). A threshold of 1.01 ×10 mm/s or less allowed an identification of invasive cancers with a sensitivity of 78.06% (95% CI, 70.7%-84.3%) and a specificity of 90.5% (95% CI, 69.6%-98.8%). No significant ADC differences were found among different tumor grades (P > 0.05). Apparent diffusion coefficient could be used as an imaging biomarker for the diagnosis of breast cancer. It seems to be a valuable noninvasive quantitative biomarker to assess breast cancer invasiveness. Thus, ADC measurements provide the potential to reduce overdiagnosis and subsequent overtreatment.
Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Dürr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea
2012-11-01
The objective of our study was to compare the diagnostic value of qualitative diffusion-weighted imaging (DWI), quantitative DWI, and chemical-shift imaging in a single prospective cohort of patients with acute osteoporotic and malignant vertebral fractures. The study group was composed of patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years; age range, 31 years 6 months to 86 years 2 months) and 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years; age range, 24 years 8 months to 86 years 4 months). T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW reverse fast imaging with steady-state free precession (PSIF) sequence at different delta values was evaluated qualitatively. A DW echo-planar imaging (EPI) sequence and a DW single-shot turbo spin-echo (TSE) sequence at different b values were evaluated qualitatively and quantitatively using the apparent diffusion coefficient. Opposed-phase sequences were used to assess signal intensity qualitatively. The signal loss between in- and opposed-phase images was determined quantitatively. Two-tailed Fisher exact test, Mann-Whitney test, and receiver operating characteristic analysis were performed. Sensitivities, specificities, and accuracies were determined. Qualitative DW-PSIF imaging (delta = 3 ms) showed the best performance for distinguishing between benign and malignant fractures (sensitivity, 100%; specificity, 88.5%; accuracy, 93.5%). Qualitative DW-EPI (b = 50 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.50]) and DW single-shot TSE imaging (b = 100 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.18]; b = 400 s/mm(2) [p = 0.18]; b = 600 s/mm(2) [p = 0.39]) did not indicate significant differences between benign and malignant fractures. DW-EPI using a b value of 500 s/mm(2) (p = 0.01) indicated significant differences between benign and malignant vertebral fractures. Quantitative DW-EPI (p = 0.09) and qualitative opposed-phase imaging (p = 0.06) did not exhibit significant differences, quantitative DW single-shot TSE imaging (p = 0.002) and quantitative chemical-shift imaging (p = 0.01) showed significant differences between benign and malignant fractures. The DW-PSIF sequence (delta = 3 ms) had the highest accuracy in differentiating benign from malignant vertebral fractures. Quantitative chemical-shift imaging and quantitative DW single-shot TSE imaging had a lower accuracy than DW-PSIF imaging because of a large overlap. Qualitative assessment of opposed-phase, DW-EPI, and DW single-shot TSE sequences and quantitative assessment of the DW-EPI sequence were not suitable for distinguishing between benign and malignant vertebral fractures.
Bennett, Kevin M; Schmainda, Kathleen M; Bennett, Raoqiong Tong; Rowe, Daniel B; Lu, Hanbing; Hyde, James S
2003-10-01
Experience with diffusion-weighted imaging (DWI) shows that signal attenuation is consistent with a multicompartmental theory of water diffusion in the brain. The source of this so-called nonexponential behavior is a topic of debate, because the cerebral cortex contains considerable microscopic heterogeneity and is therefore difficult to model. To account for this heterogeneity and understand its implications for current models of diffusion, a stretched-exponential function was developed to describe diffusion-related signal decay as a continuous distribution of sources decaying at different rates, with no assumptions made about the number of participating sources. DWI experiments were performed using a spin-echo diffusion-weighted pulse sequence with b-values of 500-6500 s/mm(2) in six rats. Signal attenuation curves were fit to a stretched-exponential function, and 20% of the voxels were better fit to the stretched-exponential model than to a biexponential model, even though the latter model had one more adjustable parameter. Based on the calculated intravoxel heterogeneity measure, the cerebral cortex contains considerable heterogeneity in diffusion. The use of a distributed diffusion coefficient (DDC) is suggested to measure mean intravoxel diffusion rates in the presence of such heterogeneity. Copyright 2003 Wiley-Liss, Inc.
Kanemasa, Yusuke; Shimoyama, Tatsu; Sasaki, Yuki; Tamura, Miho; Sawada, Takeshi; Omuro, Yasushi; Hishima, Tsunekazu; Maeda, Yoshiharu
2018-02-01
Studies that have evaluated the prognostic value of body mass index (BMI) in patients with diffuse large B-cell lymphoma have recently been reported. However, the impact of BMI on survival outcomes remains controversial. We retrospectively analyzed the data of 406 diffuse large B-cell lymphoma patients treated with R-CHOP or R-CHOP-like regimens. The number (%) of patients that were categorized into 1 of 4 groups according to BMI were underweight (<18.5 kg/m 2 ), 58 (14.3%); normal weight (≥18.5 to <25 kg/m 2 ), 262 (64.5%); overweight (≥25 to <30 kg/m 2 ), 75 (18.5%); and obese (≥30.0 kg/m 2 ), 11 (2.7%). While the prognosis of overweight patients was good, being similar to that of normal weight, underweight, and obese patients had a worse prognosis (5-y overall survival [OS] was 57.9%, 74.3%, 73.4%, and 40.9% for underweight, normal weight, overweight, and obese patients, respectively; P = .004). In multivariate analysis, underweight and obesity were independent prognostic factors for OS compared with normal weight (hazard ratios 2.90 and 5.17, respectively). In elderly female patients (≥70 y), patients with a low BMI (<25 kg/m 2 ) had significantly inferior OS than those with a high BMI (≥25 kg/m 2 ) (5-y OS, 61.5% vs 85.7%; P = .039). In contrast, in young female patients (<70 years), patients with a low BMI had significantly better OS than those with a high BMI (5-y OS, 88.6% vs 46.4%; P < .001). In male patients, there were no differences in the effect of BMI on OS between young and elderly patients. In this study, we demonstrated that being underweight and obese were independent prognostic factors compared with being normal weight. In female patients, BMI had a different impact on the prognosis of young and elderly patients, whereas in male patients, there was no difference in the effect of BMI on prognosis according to age. Copyright © 2017 John Wiley & Sons, Ltd.
Marias, Kostas; Lambregts, Doenja M. J.; Nikiforaki, Katerina; van Heeswijk, Miriam M.; Bakers, Frans C. H.; Beets-Tan, Regina G. H.
2017-01-01
Purpose The purpose of this study was to compare the performance of four diffusion models, including mono and bi-exponential both Gaussian and non-Gaussian models, in diffusion weighted imaging of rectal cancer. Material and methods Nineteen patients with rectal adenocarcinoma underwent MRI examination of the rectum before chemoradiation therapy including a 7 b-value diffusion sequence (0, 25, 50, 100, 500, 1000 and 2000 s/mm2) at a 1.5T scanner. Four different diffusion models including mono- and bi-exponential Gaussian (MG and BG) and non-Gaussian (MNG and BNG) were applied on whole tumor volumes of interest. Two different statistical criteria were recruited to assess their fitting performance, including the adjusted-R2 and Root Mean Square Error (RMSE). To decide which model better characterizes rectal cancer, model selection was relied on Akaike Information Criteria (AIC) and F-ratio. Results All candidate models achieved a good fitting performance with the two most complex models, the BG and the BNG, exhibiting the best fitting performance. However, both criteria for model selection indicated that the MG model performed better than any other model. In particular, using AIC Weights and F-ratio, the pixel-based analysis demonstrated that tumor areas better described by the simplest MG model in an average area of 53% and 33%, respectively. Non-Gaussian behavior was illustrated in an average area of 37% according to the F-ratio, and 7% using AIC Weights. However, the distributions of the pixels best fitted by each of the four models suggest that MG failed to perform better than any other model in all patients, and the overall tumor area. Conclusion No single diffusion model evaluated herein could accurately describe rectal tumours. These findings probably can be explained on the basis of increased tumour heterogeneity, where areas with high vascularity could be fitted better with bi-exponential models, and areas with necrosis would mostly follow mono-exponential behavior. PMID:28863161
Manikis, Georgios C; Marias, Kostas; Lambregts, Doenja M J; Nikiforaki, Katerina; van Heeswijk, Miriam M; Bakers, Frans C H; Beets-Tan, Regina G H; Papanikolaou, Nikolaos
2017-01-01
The purpose of this study was to compare the performance of four diffusion models, including mono and bi-exponential both Gaussian and non-Gaussian models, in diffusion weighted imaging of rectal cancer. Nineteen patients with rectal adenocarcinoma underwent MRI examination of the rectum before chemoradiation therapy including a 7 b-value diffusion sequence (0, 25, 50, 100, 500, 1000 and 2000 s/mm2) at a 1.5T scanner. Four different diffusion models including mono- and bi-exponential Gaussian (MG and BG) and non-Gaussian (MNG and BNG) were applied on whole tumor volumes of interest. Two different statistical criteria were recruited to assess their fitting performance, including the adjusted-R2 and Root Mean Square Error (RMSE). To decide which model better characterizes rectal cancer, model selection was relied on Akaike Information Criteria (AIC) and F-ratio. All candidate models achieved a good fitting performance with the two most complex models, the BG and the BNG, exhibiting the best fitting performance. However, both criteria for model selection indicated that the MG model performed better than any other model. In particular, using AIC Weights and F-ratio, the pixel-based analysis demonstrated that tumor areas better described by the simplest MG model in an average area of 53% and 33%, respectively. Non-Gaussian behavior was illustrated in an average area of 37% according to the F-ratio, and 7% using AIC Weights. However, the distributions of the pixels best fitted by each of the four models suggest that MG failed to perform better than any other model in all patients, and the overall tumor area. No single diffusion model evaluated herein could accurately describe rectal tumours. These findings probably can be explained on the basis of increased tumour heterogeneity, where areas with high vascularity could be fitted better with bi-exponential models, and areas with necrosis would mostly follow mono-exponential behavior.
Nicolas, R; Gros-Dagnac, H; Aubry, F; Celsis, P
2017-06-01
The blood oxygen level-dependent (BOLD) effect is extensively used for functional MRI (fMRI) but presents some limitations. Diffusion-weighted fMRI (DfMRI) has been proposed as a method more tightly linked to neuronal activity. This work proposes a protocol of DfMRI acquired for several b-values and diffusion directions that is compared to gradient-echo BOLD (GE-BOLD) and to repeated spin-echo BOLD (SE-BOLD, acquisitions performed with b=0s/mm 2 ), which was also used to ensure the reproducibility of the response. A block stimulation paradigm of the primary visual system (V1) was performed in 12 healthy subjects with checkerboard alternations (2Hz frequency). DfMRI was performed at 3T with 5 b-values (b=1500, 1000, 500, 250, 0s/mm 2 ) with TR/TE=1004/93ms, Δ/δ=45.4ms/30ms, and 6 spatial directions for diffusion measures. GE-BOLD was performed with a similar block stimulation design timing. Apparent Diffusion Coefficient (ADC)-fMRI was computed with all b-values used. An identical Z-score level was used for all fMRI modalities for the comparison of volumes of activation. ADC-fMRI and SE-BOLD fMRI activation locations were compared in a voxel-based analysis to a cytoarchitectural probability map of V1. SE-BOLD activation volumes represented only 55% of the GE-BOLD activation volumes (P<0.0001). DfMRI activation volumes averaged for all b-values acquired represented only 12% of GE-BOLD (P<0.0001) and only 22% of SE-BOLD activation volumes (P<0.005). Compared to SE-BOLD-fMRI, ADC-fMRI activations showed fewer pixels outside of V1 and a higher average probability of belonging to V1. DfMRI and ADC-fMRI acquisition at 3T could be easily post-processed with common neuro-imaging software. DfMRI and ADC-fMRI activation volumes were significantly smaller than those obtained with SE-BOLD. ADC-fMRI activations were more precisely localized in V1 than those of SE-BOLD-fMRI. This validated the increased capability of ADC-fMRI compared to BOLD to enhance the precision of localizing an fMRI activation in the cyto-architectural zone V1, thereby justifying the use of ADC-fMRI for neuro-scientific studies. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tanaka, Hiroaki; Takahashi, Sachiko; Yamanaka, Mari; Yoshizaki, Izumi; Sato, Masaru; Sano, Satoshi; Motohara, Moritoshi; Kobayashi, Tomoyuki; Yoshitomi, Susumu; Tanaka, Tetsuo; Fukuyama, Seijiro
2006-09-01
The diffusion coefficients of lysozyme and alpha-amylase were measured in the various polyethylene glycol (PEG) solutions. Obtained diffusion coefficients were studied with the viscosity coefficient of the solution. It was found that the diffusion process of the protein was suppressed with a factor of vγ, where ν is a relative viscosity coefficient of the PEG solution. The value of γ is -0.64 at PEG1500 for both proteins. The value increased to -0.48 at PEG8000 for lysozyme, while decreased to -0.72 for alpha-amylase. The equation of an approximate diffusion coefficient at certain PEG molecular weight and concentration was roughly obtained.
NASA Astrophysics Data System (ADS)
Ellegood, Jacob; McKay, Ryan T.; Hanstock, Chris C.; Beaulieu, Christian
2007-01-01
Although the diffusivity and anisotropy of water has been investigated thoroughly in ordered axonal systems (i.e., nervous tissue), there have been very few studies on the directional dependence of diffusion of metabolites. In this study, the mean apparent diffusion coefficient (Trace/3 ADC) and fractional anisotropy (FA) values of the intracellular metabolites N-acetyl aspartate (NAA), creatine and phosphocreatine (tCr), choline (Cho), taurine (Tau), and glutamate and glutamine (Glx) were measured parallel and perpendicular to the length of excised frog sciatic nerve using a water suppressed, diffusion-weighted, spin-echo pulse sequence at 18.8 T. The degree of anisotropy (FA) of NAA (0.41 ± 0.09) was determined to be less than tCr (0.59 ± 0.07) and Cho (0.61 ± 0.11), which is consistent with previously reported human studies of white matter. In contrast, Glx diffusion was found to be almost isotropic with an FA value of 0.20 ± 0.06. The differences of FA between the metabolites is most likely due to their differing micro-environments and could be beneficial as an indicator of compartment specific changes with disease, information not readily available with water diffusion.
Balliu, E; Vilanova, J C; Peláez, I; Puig, J; Remollo, S; Barceló, C; Barceló, J; Pedraza, S
2009-03-01
The aim of this study is to evaluate the value of the apparent diffusion coefficient (ADC) obtained in diffusion-weighted (DW) MR sequences for the differentiation between malignant and benign bone marrow lesions. Forty-five patients with altered signal intensity vertebral bodies on conventional MR sequences were included. The cause of altered signal intensity was benign osteoporotic collapse in 16, acute neoplastic infiltration in 15, and infectious processes in 14; based on plain-film, CT, bone scintigraphy, conventional MR studies, biopsy or follow-up. All patients underwent isotropic DW MR images (multi-shot EPI, b values of 0 and 500 s/mm(2)). Signal intensity at DW MR images was evaluated and ADC values were calculated and compared between malignancy, benign edema and infectious spondylitis. Acute malignant fractures were hyperintense compared to normal vertebral bodies on the diffusion-weighted sequence, except in one patient with sclerotic metastases. Mean ADC value from benign edema (1.9+/-0.39 x 10(-3) mm(2)/s) was significantly (p<0.0001) higher than untreated metastasic lesions (0.9+/-1.3 x 10(-3)mm (2)/s). Mean ADC value of infectious spondilytis (0.96+/-0.49 x 10(-3) mm(2)/s) was not statistically (p>0.05) different from untreated metastasic lesions. ADC value was low (0.75 x 10(-3) mm(2)/s) in one case of subacute benign fracture. ADC values are a useful complementary tool to characterize bone marrow lesions, in order to distinguish acute benign fractures from malignant or infectious bone lesions. However, ADC values are not valuable in order to differentiate malignancy from infection.
Bär, Sébastien; Weigel, Matthias; von Elverfeldt, Dominik; Hennig, Jürgen; Leupold, Jochen
2015-11-01
The purpose of this work was to analyze the intrinsic diffusion sensitivity of the balanced steady-state free precession (bSSFP) imaging sequence, meaning the observation of diffusion-induced attenuation of the bSSFP steady-state signal due to the imaging gradients. Although these diffusion effects are usually neglected for most clinical gradient systems, such strong gradient systems are employed for high resolution imaging of small animals or MR Microscopy. The impact on the bSSFP signal of the imaging gradients characterized by their b-values was analyzed with simulations and experiments at a 7T animal scanner using a gradient system with maximum gradient amplitude of approx. 700 mT/m. It was found that the readout gradients have a stronger impact on the attenuation than the phase encoding gradients. Also, as the PE gradients are varying with each repetition interval, the diffusion effects induce strong modulations of the bSSFP signal over the sequence repetition cycles depending on the phase encoding gradient table. It is shown that a signal gain can be obtained through a change of flip angle as a new optimal flip angle maximizing the signal can be defined. The dependency of the diffusion effects on relaxation times and b-values were explored with simulations. The attenuation increases with T2. In conclusion, diffusion attenuation of the bSSFP signal becomes significant for high resolution imaging voxel size (roughly < 100 μm) of long T2 substances. Copyright © 2015 John Wiley & Sons, Ltd.
Clarke, Sharon E; Mistry, Dipan; AlThubaiti, Talal; Khan, M Naeem; Morris, David; Bance, Manohar
2017-05-01
The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Ying, M L; Xiao, W W; Xu, S L; Shu, J E; Pan, J F; Fu, J F; Lu, J H; Pan, Y H; Jiang, Y
2016-11-20
Objective: To investigate the value of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in the differential diagnosis and blood perfusion evaluation of benign and malignant hepatic lesions. Methods: A retrospective analysis was performed for 86 patients (96 lesions) with pathologically or clinically confirmed hepatic lesions or hepatic lesions diagnosed based on follow-up results, among whom 48 had malignant lesions (53 lesions) and 38 had benign lesions (43 lesions). The patients underwent conventional magnetic resonance (MR) plain scan, contrast-enhanced scan, and diffusion-weighted imaging (DWI) with different b values (b = 0, 50, 100, 150, 200, 400, 600, 800, 1 000, and 1 200 s/mm 2 ) to determine the parameters of the double exponential model for intravoxel incoherent motion (IVIM): fast diffusion coefficient Dfast, slow diffusion coefficient Dslow, and percentage of fast-diffusion constituent F value. The patients were divided into groups according to the blood supply to lesions on conventional MR plain scan and contrast-enhanced scan, and there were 47 lesions in abundant blood supply group and 49 in poor blood supply group. The data for analysis were Dfast, Dslow, and F values of benign/malignant lesion groups and abundant/poor blood supply groups. The independent samples t-test was used for statistical analysis; the independent samples non-parametric test Mann-Whitney U test was used for the comparison of F value; the receiver operating characteristic (ROC) curve was used to evaluate the value of above parameters in the differentiation of benign and malignant lesions and blood supply evaluation. Results: Compared with the malignant lesion group, the benign lesion group had significantly higher Dslow, and F values ( P < 0.001 or P = 0.001) and a higher Dfast value ( P = 0.053). Compared with the poor blood supply group, the abundant blood supply group had significantly higher Dfast and F values ( P < 0.001 or P = 0.001) and a higher Dslow value ( P = 0.185). According to the ROC curve, the cut-off values of Dslow, Dfast, and F values in the diagnosis of benign/malignant hepatic lesions and evaluation of abundant/poor blood supply were 1.18×10 -3 mm 2 /s, 27.20×10 -3 mm 2 /s, 20.25%, 1.17×10 -3 mm 2 /s, 20.30×10 -3 mm 2 /s, and 17.80%, respectively, with sensitivities, specificities, accuracy, and areas under the ROC curve of 90.69%/92.45%/91.66%/0.938, 46.51%/73.58%/61.45%/0.589, 74.41%/50.94%/62.50%/0.653, 59.57%/57.14%/58.33%/0.559, 55.32%/63.26%/59.37%/0.618, and 93.61%/89.79%/90.62%/0.961, respectively. Conclusion: The parameter of the double exponential model for IVIM, Dslow value, has a certain value in the differential diagnosis of benign and malignant hepatic lesions, and F value can show blood perfusion in benign and malignant hepatic lesions without the need for contrast-enhanced scan, which provides a reference for the qualitative diagnosis of liver tumor.
Winfield, Jessica M; Poillucci, Gabriele; Blackledge, Matthew D; Collins, David J; Shah, Vallari; Tunariu, Nina; Kaiser, Martin F; Messiou, Christina
2018-04-01
The aim of this study was to identify apparent diffusion coefficient (ADC) values for typical haemangiomas in the spine and to compare them with active malignant focal deposits. This was a retrospective single-institution study. Whole-body magnetic resonance imaging (MRI) scans of 106 successive patients with active multiple myeloma, metastatic prostate or breast cancer were analysed. ADC values of typical vertebral haemangiomas and malignant focal deposits were recorded. The ADC of haemangiomas (72 ROIs, median ADC 1,085×10 -6 mm 2 s -1 , interquartile range 927-1,295×10 -6 mm 2 s -1 ) was significantly higher than the ADC of malignant focal deposits (97 ROIs, median ADC 682×10 -6 mm 2 s -1 , interquartile range 583-781×10 -6 mm 2 s -1 ) with a p-value < 10 -6 . Receiver operating characteristic (ROC) analysis produced an area under the curve of 0.93. An ADC threshold of 872×10 -6 mm 2 s -1 separated haemangiomas from malignant focal deposits with a sensitivity of 84.7 % and specificity of 91.8 %. ADC values of classical vertebral haemangiomas are significantly higher than malignant focal deposits. The high ADC of vertebral haemangiomas allows them to be distinguished visually and quantitatively from active sites of disease, which show restricted diffusion. • Whole-body diffusion-weighted MRI is becoming widely used in myeloma and bone metastases. • ADC values of vertebral haemangiomas are significantly higher than malignant focal deposits. • High ADCs of haemangiomas allows them to be distinguished from active disease.
The Effect of Al2O3 Addition on the Thermal Diffusivity of Heat Activated Acrylic Resin.
Atla, Jyothi; Manne, Prakash; Gopinadh, A; Sampath, Anche; Muvva, Suresh Babu; Kishore, Krishna; Sandeep, Chiramana; Chittamsetty, Harika
2013-08-01
This study aimed at investigating the effect of adding 5% to 20% by weight aluminium oxide powder (Al2O3) on thermal diffusivity of heat-polymerized acrylic resin. Twenty five cylindrical test specimens with an embedded thermocouple were used to determine thermal diffusivity over a physiologic temperature range (0 to 70°C). The specimens were divided into five groups (5 specimens/group) which were coded A to E. Group A was the control group (unmodified acrylic resin specimens). The specimens of the remaining four groups were reinforced with 5%, 10%, 15%, and 20% Al2O3 by weight. RESULTS were analysed by using one-way analysis of variance (ANOVA). Test specimens which belonged to Group E showed the highest mean thermal diffusivity value of 10.7mm(2)/sec, followed by D (9.09mm(2)/sec), C (8.49mm(2)/sec), B(8.28mm(2)/sec) and A(6.48mm(2)/sec) groups respectively. Thermal diffusivities of the reinforced acrylic resins were found to be significantly higher than that of the unmodified acrylic resin. Thermal diffusivity was found to increase in proportion to the weight percentage of alumina filler. Al2O3 fillers have potential to provide increased thermal diffusivity. Increasing the heat transfer characteristics of the acrylic resin base material could lead to more patient satisfaction.
Mapping the parameter space of a T2-dependent model of water diffusion MR in brain tissue.
Hansen, Brian; Vestergaard-Poulsen, Peter
2006-10-01
We present a new model for describing the diffusion-weighted (DW) proton nuclear magnetic resonance signal obtained from normal grey matter. Our model is analytical and, in some respects, is an extension of earlier model schemes. We model tissue as composed of three separate compartments with individual properties of diffusion and transverse relaxation. Our study assumes slow exchange between compartments. We attempt to take cell morphology into account, along with its effect on water diffusion in tissues. Using this model, we simulate diffusion-sensitive MR signals and compare model output to experimental data from human grey matter. In doing this comparison, we perform a global search for good fits in the parameter space of the model. The characteristic nonmonoexponential behavior of the signal as a function of experimental b value is reproduced quite well, along with established values for tissue-specific parameters such as volume fraction, tortuosity and apparent diffusion coefficient. We believe that the presented approach to modeling diffusion in grey matter adds new aspects to the treatment of a longstanding problem.
Diffusion-weighted magnetic resonance imaging of uterine cervical cancer.
Liu, Ying; Bai, Renju; Sun, Haoran; Liu, Haidong; Wang, Dehua
2009-01-01
To determine the feasibility of diffusion-weighted magnetic resonance (MR) imaging (DWI) of uterine cervical cancer and to investigate whether the apparent diffusion coefficient (ADC) values of cervical cancer differ from those of normal cervix and whether they could indicate the histologic type and the pathologic grade of tumor. Forty-two female patients with histopathologically proven uterine cervical cancer and 15 female patients with uterine leiomyomas underwent preoperative MR examinations using a 1.5-T clinical scanner (GE 1.5T Twin-Speed Infinity with Excite II scanner; GE Healthcare, Waukesha, Wis). Scanning sequences included T2-weighted fast spin-echo imaging, T2-weighted fast spin-echo with fat suppression imaging, T1-weighted spin-echo imaging, and DWI with diffusion factors of 0 and 1000 s/mm2. Parameters evaluated consisted of ADC values of uterine cervical cancer and normal cervix. Histologic specimens were stained with hematoxylin and eosin. The cellular densities of 32 uterine cervical cancers were calculated, which were regarded as the ratio of the total area of tumor cell nuclei divided by the area of sample image. Apparent diffusion coefficient value was statistically different (P = 0.000) between normal and cancerous tissue in the uterine cervix; the former one was (mean [SD], 1.50 [0.16]) x 10(-3) mm2/s, and the latter one was (0.88 [0.15]) x 10(-3) mm2/s. Apparent diffusion coefficient value of squamous carcinoma was statistically lower than that of adenocarcinoma (P = 0.040). The ADC value of uterine cervical cancer correlated negatively with cellular density (r = -0.711, P = 0.000) and the grading of tumor (r = -0.778, P = 0.000). Diffusion-weighted MR imaging has a potential ability to differentiate between normal and cancerous tissue in the uterine cervix, and it can indicate the histologic type of uterine cervical cancer as well. The ADC value of uterine cervical cancer represents tumor cellular density, thus providing a new method for evaluating the pathologic grading of tumor.
Stability of Gradient Field Corrections for Quantitative Diffusion MRI.
Rogers, Baxter P; Blaber, Justin; Welch, E Brian; Ding, Zhaohua; Anderson, Adam W; Landman, Bennett A
2017-02-11
In magnetic resonance diffusion imaging, gradient nonlinearity causes significant bias in the estimation of quantitative diffusion parameters such as diffusivity, anisotropy, and diffusion direction in areas away from the magnet isocenter. This bias can be substantially reduced if the scanner- and coil-specific gradient field nonlinearities are known. Using a set of field map calibration scans on a large (29 cm diameter) phantom combined with a solid harmonic approximation of the gradient fields, we predicted the obtained b-values and applied gradient directions throughout a typical field of view for brain imaging for a typical 32-direction diffusion imaging sequence. We measured the stability of these predictions over time. At 80 mm from scanner isocenter, predicted b-value was 1-6% different than intended due to gradient nonlinearity, and predicted gradient directions were in error by up to 1 degree. Over the course of one month the change in these quantities due to calibration-related factors such as scanner drift and variation in phantom placement was <0.5% for b-values, and <0.5 degrees for angular deviation. The proposed calibration procedure allows the estimation of gradient nonlinearity to correct b-values and gradient directions ahead of advanced diffusion image processing for high angular resolution data, and requires only a five-minute phantom scan that can be included in a weekly or monthly quality assurance protocol.
Aliotta, Eric; Moulin, Kévin; Zhang, Zhaohuan; Ennis, Daniel B.
2018-01-01
Purpose To evaluate a technique for simultaneous quantitative T2 and apparent diffusion coefficient (ADC) mapping in the heart (T2+ADC) using spin echo (SE) diffusion-weighted imaging (DWI). Theory and Methods T2 maps from T2+ADC were compared with single-echo SE in phantoms and with T2-prepared (T2-prep) balanced steady-state free precession (bSSFP) in healthy volunteers. ADC maps from T2+ADC were compared with conventional DWI in phantoms and in vivo. T2+ADC was also demonstrated in a patient with acute myocardial infarction (MI). Results Phantom T2 values from T2+ADC were closer to a single-echo SE reference than T2-prep bSSFP (−2.3 ± 6.0% vs 22.2 ± 16.3%; P < 0.01), and ADC values were in excellent agreement with DWI (0.28 ± 0.4%). In volunteers, myocardial T2 values from T2+ADC were significantly shorter than T2-prep bSSFP (35.8 ± 3.1 vs 46.8 ± 3.8 ms; P < 0.01); myocardial ADC was not significantly (N.S.) different between T2+ADC and conventional motion-compensated DWI (1.39 ± 0.18 vs 1.38 ± 0.18 mm2/ms; P = N.S.). In the patient, T2 and ADC were both significantly elevated in the infarct compared with remote myocardium (T2: 40.4 ± 7.6 vs 56.8 ± 22.0; P < 0.01; ADC: 1.47 ± 0.59 vs 1.65 ± 0.65 mm2/ms; P < 0.01). Conclusion T2+ADC generated coregistered, free-breathing T2 and ADC maps in healthy volunteers and a patient with acute MI with no cost in accuracy, precision, or scan time compared with DWI. PMID:28516485
Song, Ji Soo; Kwak, Hyo Sung; Byon, Jung Hee; Jin, Gong Yong
2017-05-01
To compare the apparent diffusion coefficient (ADC) of upper abdominal organs acquired at different time points, and to investigate the usefulness of normalization. We retrospectively evaluated 58 patients who underwent three rounds of magnetic resonance (MR) imaging including diffusion-weighted imaging of the upper abdomen. MR examinations were performed using three different 3.0 Tesla (T) and one 1.5T systems, with variable b value combinations and respiratory motion compensation techniques. The ADC values of the upper abdominal organs from three different time points were analyzed, using the ADC values of the paraspinal muscle (ADC psm ) and spleen (ADC spleen ) for normalization. Intraclass correlation coefficients (ICC) and comparison of dependent ICCs were used for statistical analysis. The ICCs of the original ADC and ADC psm showed fair to substantial agreement, while ADC spleen showed substantial to almost perfect agreement. The ICC of ADC spleen of all anatomical regions showed less variability compared with that of the original ADC (P < 0.005). Normalized ADC using the spleen as a reference organ significantly decreased variability in measurement of the upper abdominal organs in different MR systems at different time points and could be regarded as an imaging biomarker for future multicenter, longitudinal studies. 5 J. MAGN. RESON. IMAGING 2017;45:1494-1501. © 2016 International Society for Magnetic Resonance in Medicine.
Toslak, Iclal Erdem; Cekic, Bulent; Turk, Aysen; Eraslan, Ali; Parlak, A. Eda
2017-01-01
Purpose: Our aims were to determine the feasibility of diffusion-weighted magnetic resonance imaging (DWI) in the detection of bone marrow edema (BME) and explore the apparent diffusion coefficient (ADC) alterations in patients with osteitis pubis (OP). Materials and Methods: 42 consecutive patients clinically suspected to have athletic pubalgia and 31 control subjects were enrolled in the study. All subjects underwent diagnostic focused magnetic resonance imaging (MRI) and DWI at b values of 0 and 600 s/mm2. Two radiologists reviewed the images for the presence of active OP. The presence of subchondral BME and contrast enhancement were considered to indicate active OP. ADC values were measured from public bodies of both groups. DWI results were correlated with routine MRI findings. Receiver-operating-characteristic curves were formed. Cut-off values for ADC, sensitivity and specificity values were measured. Results: 36/42 (85%) of the cases had BME/enhancement on routine MRIs and identified as active OP. ADC measurements of the patients were greater than the controls (P < 0.05). For the optimal cut-off values DWI showed sensitivity and specificity values of 97.3%, and 90.3%, for the right, and 97.1%, and 96.7% for the left side, respectively (Area under the curve 0.965 and 0.973). Intra-and inter-rater reliability for readers were substantial-perfect for all sessions. Conclusion: DWI is fast, accurate, and highly reproducible technique for the detection of BME in patients with active OP. It allows distinct bone marrow contrast without the use of gadolinium contrast, increases visual perception of active lesions, gives objective information by quantifying the diffusion coefficients, thus increase diagnostic confidence. We suggest the use of DWI as a cost-effective adjunctive tool for the diagnosis of active OP particularly in early cases and inconclusive diagnostic MRI. Future studies are necessary to determine the utility of DWI to evaluate severity of the disease and treatment response before returning athletes to play. PMID:28190854
van Baalen, Sophie; Leemans, Alexander; Dik, Pieter; Lilien, Marc R; Ten Haken, Bennie; Froeling, Martijn
2017-07-01
To evaluate if a three-component model correctly describes the diffusion signal in the kidney and whether it can provide complementary anatomical or physiological information about the underlying tissue. Ten healthy volunteers were examined at 3T, with T 2 -weighted imaging, diffusion tensor imaging (DTI), and intravoxel incoherent motion (IVIM). Diffusion tensor parameters (mean diffusivity [MD] and fractional anisotropy [FA]) were obtained by iterative weighted linear least squares fitting of the DTI data and mono-, bi-, and triexponential fit parameters (D 1 , D 2 , D 3 , f fast2 , f fast3 , and f interm ) using a nonlinear fit of the IVIM data. Average parameters were calculated for three regions of interest (ROIs) (cortex, medulla, and rest) and from fiber tractography. Goodness of fit was assessed with adjusted R 2 ( Radj2) and the Shapiro-Wilk test was used to test residuals for normality. Maps of diffusion parameters were also visually compared. Fitting the diffusion signal was feasible for all models. The three-component model was best able to describe fast signal decay at low b values (b < 50), which was most apparent in Radj2 of the ROI containing high diffusion signals (ROI rest ), which was 0.42 ± 0.14, 0.61 ± 0.11, 0.77 ± 0.09, and 0.81 ± 0.08 for DTI, one-, two-, and three-component models, respectively, and in visual comparison of the fitted and measured S 0 . None of the models showed significant differences (P > 0.05) between the diffusion constant of the medulla and cortex, whereas the f fast component of the two and three-component models were significantly different (P < 0.001). Triexponential fitting is feasible for the diffusion signal in the kidney, and provides additional information. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:228-239. © 2016 The Authors Journal of Magnetic Resonance Imaging published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Choi, Ji Soo; Kim, Myeong-Jin; Chung, Yong Eun; Kim, Kyung Ah; Choi, Jin-Young; Lim, Joon Seok; Park, Mi-Suk; Kim, Ki Whang
2013-07-01
To compare the breathhold, navigator-triggered, and free-breathing techniques in diffusion-weighted magnetic resonance imaging (MRI) for the evaluation of focal liver lesions on a 3.0T system. Fifty-two patients (36 men, 16 women; mean age, 56.4 years) with focal liver lesions underwent breathhold, navigator-triggered, and free-breathing diffusion-weighted imaging (DWI) of the liver on a 3.0 Tesla (T) system. All sequences were performed with b values of 50 and 800 s/mm(2) and identical parameters except for signal averages (two for navigator-triggered, one for breathhold, and four for free-breathing) and repetition time (3389 ms for navigator-triggered, 1500 ms for breathhold, and 4400 ms for free-breathing). A total of 74 lesions (50 malignant, 24 benign) were evaluated. The signal-to-noise ratios (SNR) of the liver and lesions, contrast-to-noise ratios (CNR) of each lesion, and ADC values of the liver and lesions were compared for each DWI sequence. The detection sensitivity and characterization accuracy were also compared. The SNRs of the liver and lesions were significantly lower for breathhold DWI than for non-breathhold DWI (navigator-triggered and free-breathing DWI) for all b values. The CNRs of the lesions were also significantly lower for breathhold DWI than for non-breathhold DWI. The ADC values of the liver and focal lesions measured using the three DWI techniques were not significantly different and showed good correlation. For lesion detection and characterization, there were no significant differences between breathhold and non-breathhold DWI. Both breathhold and non-breathhold DWI are comparable for the detection or characterization of focal liver lesions at 3.0T; however, non-breathhold DWI provides higher SNR and CNR than breathhold DWI. In addition, although free-breathing and navigator-triggered DWI sequences show similar performance for 3.0T liver imaging, free-breathing DWI is more time efficient than navigator-triggered DWI. Copyright © 2013 Wiley Periodicals, Inc.
Ito, Katsuyoshi; Hayashida, Minoru; Kanki, Akihiko; Yamamoto, Akira; Tamada, Tsutomu; Yoshida, Koji; Tanabe, Masahiro
2018-05-17
To evaluate dynamic changes in apparent diffusion coefficient (ADC) values of the kidney at different time points during the cardiac cycle using electrocardiographic (ECG)-triggered diffusion-weighted MR imaging in normal subjects, and to elucidate the differences in ADC values between the right and left kidneys during a cardiac cycle. The study was approved by our institutional review board and informed consent was obtained from subjects. Twenty healthy volunteers who underwent ECG-triggered diffusion-weighted MR imaging of the kidney were included. The differences in ADC values of each kidney during different cardiac phases were compared. Additionally, the differences in maximum and minimum ADC values between the right and left kidney were also evaluated. ADC values in the right and left kidney changed significantly during the cardiac cycle (P < 0.00001). Maximum and minimum ADC values during the cardiac cycle of the left kidney were significantly higher (P = 0.026 and 0.017, respectively) than those of the right kidney. Maximum ADC value in the left kidney had a significantly strong positive correlation with the left renal vein ratio (r = 0.83, P < 0.00001). In the right kidney, maximum ADC showed a weakly positive correlation with the diameter of the right renal vein (r = 0.45, P = 0.048). ADC values of the kidney obtained using ECG-triggered diffusion-weighted MR imaging change significantly during the cardiac cycle. Maximum (systolic) ADC during the cardiac cycle of the left kidney was significantly higher than that of the right kidney, probably due to the anatomical difference in the renal vein. Copyright © 2018 Elsevier Inc. All rights reserved.
Iima, Mami; Kataoka, Masako; Kanao, Shotaro; Onishi, Natsuko; Kawai, Makiko; Ohashi, Akane; Sakaguchi, Rena; Toi, Masakazu; Togashi, Kaori
2018-05-01
Purpose To investigate the performance of integrated approaches that combined intravoxel incoherent motion (IVIM) and non-Gaussian diffusion parameters compared with the Breast Imaging and Reporting Data System (BI-RADS) to establish multiparameter thresholds scores or probabilities by using Bayesian analysis to distinguish malignant from benign breast lesions and their correlation with molecular prognostic factors. Materials and Methods Between May 2013 and March 2015, 411 patients were prospectively enrolled and 199 patients (allocated to training [n = 99] and validation [n = 100] sets) were included in this study. IVIM parameters (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion parameters (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm 2 [ADC 0 ] and kurtosis [K]) by using IVIM and kurtosis models were estimated from diffusion-weighted image series (16 b values up to 2500 sec/mm 2 ), as well as a synthetic ADC (sADC) calculated by using b values of 200 and 1500 (sADC 200-1500 ) and a standard ADC calculated by using b values of 0 and 800 sec/mm 2 (ADC 0-800 ). The performance of two diagnostic approaches (combined parameter thresholds and Bayesian analysis) combining IVIM and diffusion parameters was evaluated and compared with BI-RADS performance. The Mann-Whitney U test and a nonparametric multiple comparison test were used to compare their performance to determine benignity or malignancy and as molecular prognostic biomarkers and subtypes of breast cancer. Results Significant differences were found between malignant and benign breast lesions for IVIM and non-Gaussian diffusion parameters (ADC 0 , K, fIVIM, fIVIM · D*, sADC 200-1500, and ADC 0-800 ; P < .05). Sensitivity and specificity for the validation set by radiologists A and B were as follows: sensitivity, 94.7% and 89.5%, and specificity, 75.0% and 79.2% for sADC 200-1500 , respectively; sensitivity, 94.7% and 96.1%, and specificity, 75.0% and 66.7%, for the combined thresholds approach, respectively; sensitivity, 92.1% and 92.1%, and specificity, 83.3% and 66.7%, for Bayesian analysis, respectively; and sensitivity and specificity, 100% and 79.2%, for BI-RADS, respectively. The significant difference in values of sADC 200-1500 in progesterone receptor status (P = .002) was noted. sADC 200-1500 was significantly different between histologic subtypes (P = .006). Conclusion Approaches that combined various IVIM and non-Gaussian diffusion MR imaging parameters may provide BI-RADS-equivalent scores almost comparable to BI-RADS categories without the use of contrast agents. Non-Gaussian diffusion parameters also differed by biologic prognostic factors. © RSNA, 2017 Online supplemental material is available for this article.
Group-based strategy diffusion in multiplex networks with weighted values
NASA Astrophysics Data System (ADS)
Yu, Jianyong; Jiang, J. C.; Xiang, Leijun
2017-03-01
The information diffusion of multiplex social networks has received increasing interests in recent years. Actually, the multiplex networks are made of many communities, and it should be gotten more attention for the influences of community level diffusion, besides of individual level interactions. In view of this, this work explores strategy interactions and diffusion processes in multiplex networks with weighted values from a new perspective. Two different groups consisting of some agents with different influential strength are firstly built in each layer network, the authority and non-authority groups. The strategy interactions between different groups in intralayer and interlayer networks are performed to explore community level diffusion, by playing two classical strategy games, Prisoner's Dilemma and Snowdrift Game. The impact forces from the different groups and the reactive forces from individual agents are simultaneously taken into account in intralayer and interlayer interactions. This paper reveals and explains the evolutions of cooperation diffusion and the influences of interlayer interaction tight degrees in multiplex networks with weighted values. Some thresholds of critical parameters of interaction degrees and games parameters settings are also discussed in group-based strategy diffusion.
Sauer, Alexander; Li, Mengxia; Holl-Wieden, Annette; Pabst, Thomas; Neubauer, Henning
2017-10-12
Diffusion-weighted MRI has been proposed as a new technique for imaging synovitis without intravenous contrast application. We investigated diagnostic utility of multi-shot readout-segmented diffusion-weighted MRI (multi-shot DWI) for synovial imaging of the knee joint in patients with juvenile idiopathic arthritis (JIA). Thirty-two consecutive patients with confirmed or suspected JIA (21 girls, median age 13 years) underwent routine 1.5 T MRI with contrast-enhanced T1w imaging (contrast-enhanced MRI) and with multi-shot DWI (RESOLVE, b-values 0-50 and 800 s/mm 2 ). Contrast-enhanced MRI, representing the diagnostic standard, and diffusion-weighted images at b = 800 s/mm 2 were separately rated by three independent blinded readers at different levels of expertise for the presence and the degree of synovitis on a modified 5-item Likert scale along with the level of subjective diagnostic confidence. Fourteen (44%) patients had active synovitis and joint effusion, nine (28%) patients showed mild synovial enhancement not qualifying for arthritis and another nine (28%) patients had no synovial signal alterations on contrast-enhanced imaging. Ratings by the 1st reader on contrast-enhanced MRI and on DWI showed substantial agreement (κ = 0.74). Inter-observer-agreement was high for diagnosing, or ruling out, active arthritis of the knee joint on contrast-enhanced MRI and on DWI, showing full agreement between 1st and 2nd reader and disagreement in one case (3%) between 1st and 3rd reader. In contrast, ratings in cases of absent vs. little synovial inflammation were markedly inconsistent on DWI. Diagnostic confidence was lower on DWI, compared to contrast-enhanced imaging. Multi-shot DWI of the knee joint is feasible in routine imaging and reliably diagnoses, or rules out, active arthritis of the knee joint in paediatric patients without the need of gadolinium-based i.v. contrast injection. Possibly due to "T2w shine-through" artifacts, DWI does not reliably differentiate non-inflamed joints from knee joints with mild synovial irritation.
Terada, Masaki; Matsushita, Hiroki; Oosugi, Masanori; Inoue, Kazuyasu; Yaegashi, Taku; Anma, Takeshi
2009-03-20
The advantage of the higher signal-to-noise ratio (SNR) of 3-Tesla magnetic resonance imaging (3-Tesla) has the possibility of contributing to the improvement of high spatial resolution without causing image deterioration. In this study, we compared SNR and the apparent diffusion coefficient (ADC) value with 3-Tesla as the condition in the diffusion-weighted image (DWI) parameter of the 1.5-Tesla magnetic resonance imaging (1.5-Tesla) and we examined the high spatial resolution images in the imaging method [respiratory-triggering (RT) method and breath free (BF) method] and artifact (motion and zebra) in the upper abdominal region of DWI at 3-Tesla. We have optimized scan parameters based on phantom and in vivo study. As a result, 3-Tesla was able to obtain about 1.5 times SNR in comparison with the 1.5-Tesla, ADC value had few differences. Moreover, the RT method was effective in correcting the influence of respiratory movement in comparison with the BF method, and image improvement by the effective acquisition of SNR and reduction of the artifact were provided. Thus, DWI of upper abdominal region was a useful sequence for the high spatial resolution in 3-Tesla.
Grain boundary diffusion of Dy films prepared by magnetron sputtering for sintered Nd–Fe–B magnets
NASA Astrophysics Data System (ADS)
Chen, W.; Luo, J. M.; Guan, Y. W.; Huang, Y. L.; Chen, M.; Hou, Y. H.
2018-05-01
Dy films, deposited on the surface of sintered Nd–Fe–B magnets by magnetron sputtering, were employed for grain boundary diffusion source. High coercivity sintered Nd–Fe–B magnets were successfully prepared. Effects of sputtering power and grain boundary diffusion processes (GBDP) on the microstructure and magnetic properties were investigated in detail. The dense and uniform Dy films were beneficial to prepare high coercivity magnets by GBDP. The maximum coercivity value of 1189 kA m‑1 could be shown, which was an amplification of 22.3%, compared with that of as-prepared Nd–Fe–B magnet. Furthermore, the improved remanence and maximum energy product were also achieved through tuning grain boundary diffusion processes. Our results demonstrated that the formation of (Nd, Dy)2Fe14B shell surrounding Nd2Fe14B grains and fine, uniform and continuous intergranular RE-rich phases jointly contribute to the improved coercivity.
Terada, Yukinori; Toda, Hiroki; Okumura, Ryosuke; Ikeda, Naokado; Yuba, Yoshiaki; Katayama, Toshiro; Iwasaki, Koichi
2018-03-01
Microcystic meningioma, a rare meningioma subtype, can present diagnostic difficulty. We aimed to investigate the historadiological properties of microcystic meningioma using conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) analysis. We retrospectively analyzed conventional MRI and DWI results of six microcystic meningioma cases by examining their appearance and determining their apparent diffusion coefficient (ADC) values. The ADC values of the intratumoral components were normalized with ADC values of the cerebrospinal fluid in the lateral ventricle (ADC ratios). As cystic formations are frequently associated with microcystic meningiomas, their MRI characteristics were compared with the imaging data from 11 cystic meningiomas of non-microcystic subtypes. We found that cysts in microcystic meningioma tended to have a reticular appearance on DWI, as they did on gadolinium-enhanced T1-weighted imaging. Additionally, these reticular cysts had significantly lower ADC ratios than microcystic non-reticular and non-microcystic cysts. These DWI characteristics likely reflect the histological properties of microcystic meningioma. A reticular appearance on gadolinium-enhanced T1-weighted MRI and DWI, and cyst formation with relatively low ADC values can be diagnostic markers of microcystic meningiomas.
Chen, Xiao-Li; Chen, Tian-Wu; Zhang, Xiao-Ming; Li, Zhen-Lin; Li, Hang; Zeng, Nan-Lin; Tang, Hong-Jie; Pu, Yu; Chen, Nan; Yang, Qi; Li, Li; Xie, Xian-Yong; Hu, Jiani
2013-11-01
To determine whether spleen diffusion-weighted imaging (DWI) parameters might classify liver fibrosis stage. Sixteen miniature pigs were prospectively used to model liver fibrosis, and underwent spleen DWI by using b = 300, 500 and 800 s/mm(2) on 0, 5th, 9th, 16th and 21st weekend after the beginning of modeling. Signal intensity ratio of spleen to paraspinous muscles (S/M), spleen exponential apparent diffusion coefficient (eADC) and apparent diffusion coefficient (ADC) for each b-value were statistically analyzed. With increasing stages of fibrosis, S/M for all b-values showed a downward trend; and spleen eADC and ADC for b = 300 s/mm(2) showed downward and upward trends, respectively (all P < 0.05). The area under the receiver-operator curve (AUC) of spleen DWI parameters was 0.777 or more by S/M for classifying each fibrosis stage, and 0.65 or more by eADC and 0.648 or more by ADC for classifying stage ≥3 or cirrhosis. Among the spleen DWI parameters, S/M for b = 300 s/mm(2) was the best parameter in classifying stage 1 or more, 2 or more and 3 or more with AUC of 0.875, 0.851 and 0.843, respectively; and spleen eADC for b = 300 s/mm(2) was best in classifying stage 4 with an AUC of 0.988. Spleen DWI may be used to stage liver fibrosis. © 2013 The Japan Society of Hepatology.
Warthin tumor of the parotid gland: diagnostic value of MR imaging with histopathologic correlation.
Ikeda, Mitsuaki; Motoori, Ken; Hanazawa, Toyoyuki; Nagai, Yuichiro; Yamamoto, Seiji; Ueda, Takuya; Funatsu, Hiroyuki; Ito, Hisao
2004-08-01
The purpose of our study was to describe the MR imaging appearance of Warthin tumors multiple MR imaging techniques and to interpret the difference in appearance from that of malignant parotid tumors. T1-weighted, T2-weighted, short inversion time inversion recovery, diffusion-weighted, and contrast-enhanced dynamic MR images of 19 Warthin tumors and 17 malignant parotid tumors were reviewed. MR imaging results were compared with those of pathologic analysis. Epithelial stromata and lymphoid tissue with slitlike small cysts in Warthin tumors showed early enhancement and a high washout rate (> or =30%) on dynamic contrast-enhanced images, and accumulations of complicated cysts showed early enhancement and a low washout ratio (< 30%). The areas containing complicated cysts showed high signal intensity on T1-weighted images, whereas some foci in those areas showed low signal intensity on short tau inversion recovery images. The mean minimum signal intensity ratios (SIRmin) of Warthin tumor on short tau inversion recovery (0.29 +/- 0.22 SD) (P < .01) and T2-weighted images (0.28 +/- 0.09) (P < .05) were significantly lower than those of malignant parotid tumors (0.53 +/- 0.19, 0.48 +/- 0.19). The average washout ratio of Warthin tumors (44.0 +/- 20.4%) was higher than that of malignant parotid tumors (11.9 +/- 11.6%). The mean apparent diffusion coefficient of Warthin tumors (0.96 +/- 0.13 x 10(-3)mm2/s) was significantly lower (P < .01) than that of malignant tumors (1.19 +/- 0.19 x 10(-3)mm2/s). Detecting hypointense areas of short tau inversion recovery and T2-weighted images or low apparent diffusion coefficient values on diffusion-weighted images was useful for predicting whether salivary gland tumors were Warthin tumors. The findings of the dynamic contrast-enhanced study also were useful.
Diffusion-Weighted Imaging of Traumatic Optic Neuropathy: Diagnosis and Predicting the Prognosis
2014-01-01
AFRL-SA-WP-SR-2014-0004 Diffusion-Weighted Imaging of Traumatic Optic Neuropathy : Diagnosis and Predicting the Prognosis...Diffusion-Weighted Imaging of Traumatic Optic Neuropathy : Diagnosis and Predicting the Prognosis 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...Skills Institute C-STARS Baltimore 2510 Fifth St. Wright-Patterson AFB, OH 45433-7913 8 . PERFORMING ORGANIZATION REPORT NUMBER AFRL-SA
Kakite, Suguru; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Facciuto, Marcelo; Donnerhack, Claudia; Taouli, Bachir
2015-01-01
To evaluate short-term test-retest and interobserver reproducibility of IVIM (intravoxel incoherent motion) diffusion parameters and ADC (apparent diffusion coefficient) of hepatocellular carcinoma (HCC) and liver parenchyma at 3.0T. In this prospective Institutional Review Board (IRB)-approved study, 11 patients were scanned twice using a free-breathing single-shot echo-planar-imaging, diffusion-weighted imaging (DWI) sequence using 4 b values (b = 0, 50, 500, 1000 s/mm(2)) and IVIM DWI using 16 b values (0-800 s/mm(2)) at 3.0T. IVIM parameters (D: true diffusion coefficient, D*: pseudodiffusion coefficient, PF: perfusion fraction) and ADC (using 4 b and 16 b) were calculated. Short-term test-retest and interobserver reproducibility of IVIM parameters and ADC were assessed by measuring correlation coefficient, coefficient of variation (CV), and Bland-Altman limits of agreements (BA-LA). Fifteen HCCs were assessed in 10 patients. Reproducibility of IVIM metrics in HCC was poor for D* and PF (mean CV 60.6% and 37.3%, BA-LA: -161.6% to 135.3% and -66.2% to 101.0%, for D* and PF, respectively), good for D and ADC (CV 19.7% and <16%, BA-LA -57.4% to 36.3% and -38.2 to 34.1%, for D and ADC, respectively). Interobserver reproducibility was on the same order of test-retest reproducibility except for PF in HCC. Reproducibility of diffusion parameters was better in liver parenchyma compared to HCC. Poor reproducibility of D*/PF and good reproducibility for D/ADC were observed in HCC and liver parenchyma. These findings may have implications for trials using DWI in HCC. © 2014 Wiley Periodicals, Inc.
Diffusion-weighted magnetic resonance imaging in autoimmune pancreatitis.
Taniguchi, Takao; Kobayashi, Hisato; Nishikawa, Koji; Iida, Etsushi; Michigami, Yoshihiro; Morimoto, Emiko; Yamashita, Rikiya; Miyagi, Ken; Okamoto, Motozumi
2009-04-01
The aim of this study was to investigate the usefulness of diffusion-weighted magnetic resonance imaging (DWI MRI) for the diagnosis and evaluation of autoimmune pancreatitis (AIP). A total of 4 consecutive patients with AIP, 5 patients with chronic alcoholic pancreatitis (CP), and 13 patients without pancreatic disease (controls) were studied. DWI was performed in the axial plane with spin-echo echo-planar imaging single-shot sequence. Apparent diffusion coefficients (ADCs) were measured in circular regions of interest in the pancreas. In AIP patients, abdominal MRI was performed before, and 2-4 weeks after steroid treatment. Follow-up study was performed chronologically for up to 11 months in two patients. The correlation between ADCs of the pancreas and the immunoglobulin G4 (IgG4) index (serum IgG4 value/serum IgG4 value before steroid treatment) was evaluated. In the AIP patients, DWI of the pancreas showed high signal intensity, and the ADCs of the pancreas (mean +/- SD: 0.97 +/- 0.18 x 10(-3) mm(2)/s) were significantly lower than those in patients with CP (1.45 +/- 0.10 x 10(-3) mm(2)/s) or the controls (1.45 +/- 0.16 x 10(-3) mm(2)/s) (Mann-Whitney U-test, P < 0.05). In one AIP patient with focal swelling of the pancreas head that appeared to be a mass, DWI showed high signal intensity throughout the pancreas, indicating diffuse involvement. The ADCs of the pancreas and IgG4 index were significantly inversely correlated (Spearman's rank correlation coefficient, r (s) = -0.80, P < 0.05). Autoimmune pancreatitis showed high signal intensity on DWI, which improved after steroid treatment. ADCs reflected disease activity. Thus, diffusion-weighted MRI might be useful for diagnosing AIP, determining the affected area, and evaluating the effect of treatment.
The Effect of Al2O3 Addition on the Thermal Diffusivity of Heat Activated Acrylic Resin
Atla, Jyothi; Manne, Prakash; Gopinadh, A.; Sampath, Anche; Muvva, Suresh Babu; Kishore, Krishna; Sandeep, Chiramana; Chittamsetty, Harika
2013-01-01
Aim: This study aimed at investigating the effect of adding 5% to 20% by weight aluminium oxide powder (Al2O3) on thermal diffusivity of heat–polymerized acrylic resin. Material and Methods: Twenty five cylindrical test specimens with an embedded thermocouple were used to determine thermal diffusivity over a physiologic temperature range (0 to 70°C). The specimens were divided into five groups (5 specimens/group) which were coded A to E. Group A was the control group (unmodified acrylic resin specimens). The specimens of the remaining four groups were reinforced with 5%, 10%, 15%, and 20% Al2O3 by weight. Results were analysed by using one–way analysis of variance (ANOVA). Results: Test specimens which belonged to Group E showed the highest mean thermal diffusivity value of 10.7mm2/sec, followed by D (9.09mm2/sec), C (8.49mm2/sec), B(8.28mm2/sec) and A(6.48mm2/sec) groups respectively. Thermal diffusivities of the reinforced acrylic resins were found to be significantly higher than that of the unmodified acrylic resin. Thermal diffusivity was found to increase in proportion to the weight percentage of alumina filler. Conclusion: Al2O3 fillers have potential to provide increased thermal diffusivity. Increasing the heat transfer characteristics of the acrylic resin base material could lead to more patient satisfaction. PMID:24086917
Sun, Kun; Chen, Xiaosong; Chai, Weimin; Fei, Xiaochun; Fu, Caixia; Yan, Xu; Zhan, Ying; Chen, Kemin; Shen, Kunwei; Yan, Fuhua
2015-10-01
To assess diagnostic accuracy with diffusion kurtosis imaging (DKI) in patients with breast lesions and to evaluate the potential association between DKI-derived parameters and breast cancer clinical-pathologic factors. Institutional review board approval and written informed consent were obtained. Data from 97 patients (mean age ± standard deviation, 45.7 years ± 13.1; range, 19-70 years) with 98 lesions (57 malignant and 41 benign) who were treated between January 2014 and April 2014 were retrospectively analyzed. DKI (with b values of 0-2800 sec/mm(2)) and conventional diffusion-weighted imaging data were acquired. Kurtosis and diffusion coefficients from DKI and apparent diffusion coefficients from diffusion-weighted imaging were measured by two radiologists. Student t test, Wilcoxon signed-rank test, Jonckheere-Terpstra test, receiver operating characteristic curves, and Spearman correlation were used for statistical analysis. Kurtosis coefficients were significantly higher in the malignant lesions than in the benign lesions (1.05 ± 0.22 vs 0.65 ± 0.11, respectively; P < .0001). Diffusivity and apparent diffusion coefficients in the malignant lesions were significantly lower than those in the benign lesions (1.13 ± 0.27 vs 1.97 ± 0.33 and 1.02 ± 0.18 vs 1.48 ± 0.33, respectively; P < .0001). Significantly higher specificity for differentiation of malignant from benign lesions was shown with the use of kurtosis and diffusivity coefficients than with the use of apparent diffusion coefficients (83% [34 of 41] and 83% [34 of 41] vs 76% [31 of 41], respectively; P < .0001) with equal sensitivity (95% [54 of 57]). In patients with invasive breast cancer, kurtosis was positively correlated with tumor histologic grade (r = 0.75) and expression of the Ki-67 protein (r = 0.55). Diffusivity was negatively correlated with tumor histologic grades (r = -0.44) and Ki-67 expression (r = -0.46). DKI showed higher specificity than did conventional diffusion-weighted imaging for assessment of benign and malignant breast lesions. Patients with grade 3 breast cancer or tumors with high expression of Ki-67 were associated with higher kurtosis and lower diffusivity coefficients; however, this association must be confirmed in prospective studies. (©) RSNA, 2015 Online supplemental material is available for this article.
Sadinski, Meredith; Karczmar, Gregory; Peng, Yahui; Wang, Shiyang; Jiang, Yulei; Medved, Milica; Yousuf, Ambereen; Antic, Tatjana; Oto, Aytekin
2016-09-01
The objective of our study was to evaluate the role of a hybrid T2-weighted imaging-DWI sequence for prostate cancer diagnosis and differentiation of aggressive prostate cancer from nonaggressive prostate cancer. Twenty-one patients with prostate cancer who underwent preoperative 3-T MRI and prostatectomy were included in this study. Patients underwent a hybrid T2-weighted imaging-DWI examination consisting of DW images acquired with TEs of 47, 75, and 100 ms and b values of 0 and 750 s/mm(2). The apparent diffusion coefficient (ADC) and T2 were calculated for cancer and normal prostate ROIs at each TE and b value. Changes in ADC and T2 as a function of increasing the TE and b value, respectively, were analyzed. A new metric termed "PQ4" was defined as the percentage of voxels within an ROI that has increasing T2 with increasing b value and has decreasing ADC with increasing TE. ADC values were significantly higher in normal ROIs than in cancer ROIs at all TEs (p < 0.0001). With increasing TE, the mean ADC increased 3% in cancer ROIs and increased 12% in normal ROIs. T2 was significantly higher in normal ROIs than in cancer ROIs at both b values (p ≤ 0.0002). The mean T2 decreased with increasing b value in cancer ROIs (ΔT2 = -17 ms) and normal ROIs (ΔT2 = -52 ms). PQ4 clearly differentiated normal ROIs from prostate cancer ROIs (p = 0.0004) and showed significant correlation with Gleason score (ρ = 0.508, p < 0.0001). Hybrid MRI measures the response of ADC and T2 to changing TEs and b values, respectively. This approach shows promise for detecting prostate cancer and determining its aggressiveness noninvasively.
Guan, Yue; Shi, Hua; Chen, Ying; Liu, Song; Li, Weifeng; Jiang, Zhuoran; Wang, Huanhuan; He, Jian; Zhou, Zhengyang; Ge, Yun
2016-01-01
The aim of this study was to explore the application of whole-lesion histogram analysis of apparent diffusion coefficient (ADC) values of cervical cancer. A total of 54 women (mean age, 53 years) with cervical cancers underwent 3-T diffusion-weighted imaging with b values of 0 and 800 s/mm prospectively. Whole-lesion histogram analysis of ADC values was performed. Paired sample t test was used to compare differences in ADC histogram parameters between cervical cancers and normal cervical tissues. Receiver operating characteristic curves were constructed to identify the optimal threshold of each parameter. All histogram parameters in this study including ADCmean, ADCmin, ADC10%-ADC90%, mode, skewness, and kurtosis of cervical cancers were significantly lower than those of normal cervical tissues (all P < 0.0001). ADC90% had the largest area under receiver operating characteristic curve of 0.996. Whole-lesion histogram analysis of ADC maps is useful in the assessment of cervical cancer.
Comparison of cumulant expansion and q-space imaging estimates for diffusional kurtosis in brain.
Mohanty, Vaibhav; McKinnon, Emilie T; Helpern, Joseph A; Jensen, Jens H
2018-05-01
To compare estimates for the diffusional kurtosis in brain as obtained from a cumulant expansion (CE) of the diffusion MRI (dMRI) signal and from q-space (QS) imaging. For the CE estimates of the kurtosis, the CE was truncated to quadratic order in the b-value and fit to the dMRI signal for b-values from 0 up to 2000s/mm 2 . For the QS estimates, b-values ranging from 0 up to 10,000s/mm 2 were used to determine the diffusion displacement probability density function (dPDF) via Stejskal's formula. The kurtosis was then calculated directly from the second and fourth order moments of the dPDF. These two approximations were studied for in vivo human data obtained on a 3T MRI scanner using three orthogonal diffusion encoding directions. The whole brain mean values for the CE and QS kurtosis estimates differed by 16% or less in each of the considered diffusion encoding directions, and the Pearson correlation coefficients all exceeded 0.85. Nonetheless, there were large discrepancies in many voxels, particularly those with either very high or very low kurtoses relative to the mean values. Estimates of the diffusional kurtosis in brain obtained using CE and QS approximations are strongly correlated, suggesting that they encode similar information. However, for the choice of b-values employed here, there may be substantial differences, depending on the properties of the diffusion microenvironment in each voxel. Copyright © 2018 Elsevier Inc. All rights reserved.
Nakahira, Mitsuhiko; Saito, Naoko; Yamaguchi, Hiroshi; Kuba, Kiyomi; Sugasawa, Masashi
2014-05-01
Although identification of human papilloma virus (HPV) status in oropharyngeal squamous cell carcinoma (OPSCC) is essential in predicting treatment response, no imaging modality can currently determine whether a tumor is HPV-related. In this retrospective study, 26 patients with OPSCC confined to the lateral wall or the base of tongue underwent neck magnetic resonance imaging, using T1-, T2- and diffusion-weighted imaging (DWI). Apparent diffusion coefficients (ADCs) in a region of interest covering the largest available primary tumor area of OPSCC on a single slice of the ADC map were calculated using two b values (0 and 1,000 s/mm(2)). Mean and minimum ADCs were compared with HPV status, using p16 immunohistochemistry as a surrogate marker for HPV infection. Mean and minimum ADCs for HPV(+) OPSCC were significantly lower than those for HPV(-) OPSCC. A cut-off value of mean ADC for HPV(+) OPSCC of 1.027 × 10(-3) mm(2)/s yielded sensitivity and specificity of 83.33 and 78.57%, respectively. In conclusion, the present study indicates that ADC could be used to predict HPV status in patients with OPSCC.
Iqbal, Samina; Marchetti, Roberta; Aman, Afsheen; Silipo, Alba; Qader, Shah Ali Ul; Molinaro, Antonio
2017-10-01
Low molecular weight fractions were derived from native high molecular weight dextran produced by Leuconostoc mesenteroides KIBGE-IB26. Structural characterization of native and low molecular weight fractions obtained after acidic and enzymatic hydrolysis was done using FTIR and NMR spectroscopy. The molecular weight was estimated using Diffusion Ordered NMR spectroscopy. Native dextran (892kDa) is composed of α-(1→6) glycosidic linkage along with α-(1→3) branching. Major proportion of 528kDa dextran was obtained after prolong enzymatic hydrolysis however, an effective acidic treatment at pH-1.4 up to 02 and 04h of exposure resulted in the formation of 77kDa and 57kDa, respectively. The increment in pH from 1.4 to 1.8 lowered the hydrolysis efficiency and resulted in the formation of 270kDa dextran fraction. The results suggest that derived low molecular weight water soluble fractions can be utilized as a drug delivery carrier along with multiple application relating pharmaceutical industries. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Hai Ming; Liu, Jia; Qiang, Jin Wei; Gu, Wei Yong; Zhang, Guo Fu; Ma, Feng Hua
2017-11-01
This study aimed to investigate the conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) features of endometrial stromal sarcoma (ESS) including a preliminary investigation of the correlation between the apparent diffusion coefficient (ADC) value and Ki-67 expression. The clinical and MRI data of 15 patients with ESS confirmed by surgery and pathology were analyzed retrospectively. The conventional MR morphological features, signal intensity on DWI, ADC value (n = 14), and clinicopathological marker Ki-67 (n = 13) were evaluated. Of 15 patients with ESS, 13 tumors were low-grade ESS (LGESS), and the remaining 2 were high-grade ESS (HGESS); 9 tumors were located in the myometrium, 5 were located in the endometrium and/or cervical canal, and 1 was located in extrauterine. Thirteen (87%) of 15 tumors showed a homo- or heterogeneous isointensity on T1-weighted imaging and a heterogeneous hyperintensity on T2-weighted imaging. The hypointense bands were observed in 11 tumors (73%) on T2-weighted imaging. The degenerations (cystic/necrosis/hemorrhage) were observed in 7 LGESS tumors and 2 HGESS tumors. The DWI hyperintensity was observed in 13 tumors (93%) and isointensity in remaining 1. The mean ADC value of the solid components in 14 ESSs was (1.05 ± 0.20) × 10mm/s. The contrast-enhanced MRI showed an obvious enhancement in 14 tumors (93%) (heterogeneous in 7 LGESSs and 2 HGESSs; homogeneous in 5 LGESSs). The ADC value was inversely correlated with the Ki-67 expression (r = -0.613, P = 0.026). Patients with ESS showed some characteristics on conventional MRI and DWI, and there was an inverse correlation between the ADC value and Ki-67 expression.
Ligneul, Clémence; Palombo, Marco
2016-01-01
Purpose To assess the potential correlation between metabolites diffusion and relaxation in the mouse brain, which is of importance for interpreting and modeling metabolite diffusion based on pure geometry, irrespective of relaxation properties (multicompartmental relaxation or surface relaxivity). Methods A new diffusion‐weighted magnetic resonance spectroscopy sequence is introduced, dubbed “STE‐LASER,” which presents several nice properties, in particular the absence of cross‐terms with selection gradients and a very clean localization. Metabolite diffusion is then measured in a large voxel in the mouse brain at 11.7 Tesla using a cryoprobe, resulting in excellent signal‐to‐noise ratio, up to very high b‐values under different echo time, mixing time, and diffusion time combinations. Results Our results suggest that the correlation between relaxation and diffusion properties is extremely small or even nonexistent for metabolites in the mouse brain. Conclusion The present work strongly supports the interpretation and modeling of metabolite diffusion primarily based on geometry, irrespective of relaxation properties, at least under current experimental conditions. Magn Reson Med 77:1390–1398, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. PMID:27018415
Tensor Based Representation and Analysis of Diffusion-Weighted Magnetic Resonance Images
ERIC Educational Resources Information Center
Barmpoutis, Angelos
2009-01-01
Cartesian tensor bases have been widely used to model spherical functions. In medical imaging, tensors of various orders can approximate the diffusivity function at each voxel of a diffusion-weighted MRI data set. This approximation produces tensor-valued datasets that contain information about the underlying local structure of the scanned tissue.…
Lemaire, L; Howe, F A; Rodrigues, L M; Griffiths, J R
1999-03-01
Chemosensitivity of N-methyl-N-nitrosourea-induced rat mammary tumours treated with 5-fluorouracil at a dose of 100 mg kg(-1) i.p. was assessed by using diffusion-weighted 1H-MRS to measure the average diffusion coefficient (ADC) of water in the tumour tissue. ADC measurements prior to any therapy correlated positively with necrotic fraction. Tumours with low initial ADC (< 0.95 x 10(9) m2 s(-1)) showed an increase in ADC 7 days after treatment, whereas tumours with a high initial ADC (> 1.2 x 10(9) m2 s(-1)) showed a decrease. All tumours decreased significantly in volume (P < 0.05) 2, 5 and 7 days after treatment. At day 7 post-treatment, tumours with a high pre-treatment ADC started to regrow. The initial ADC value, as well as changes after treatment predict tumour chemosensitivity, which could be clinically relevant.
HARDI DATA DENOISING USING VECTORIAL TOTAL VARIATION AND LOGARITHMIC BARRIER
Kim, Yunho; Thompson, Paul M.; Vese, Luminita A.
2010-01-01
In this work, we wish to denoise HARDI (High Angular Resolution Diffusion Imaging) data arising in medical brain imaging. Diffusion imaging is a relatively new and powerful method to measure the three-dimensional profile of water diffusion at each point in the brain. These images can be used to reconstruct fiber directions and pathways in the living brain, providing detailed maps of fiber integrity and connectivity. HARDI data is a powerful new extension of diffusion imaging, which goes beyond the diffusion tensor imaging (DTI) model: mathematically, intensity data is given at every voxel and at any direction on the sphere. Unfortunately, HARDI data is usually highly contaminated with noise, depending on the b-value which is a tuning parameter pre-selected to collect the data. Larger b-values help to collect more accurate information in terms of measuring diffusivity, but more noise is generated by many factors as well. So large b-values are preferred, if we can satisfactorily reduce the noise without losing the data structure. Here we propose two variational methods to denoise HARDI data. The first one directly denoises the collected data S, while the second one denoises the so-called sADC (spherical Apparent Diffusion Coefficient), a field of radial functions derived from the data. These two quantities are related by an equation of the form S = SSexp (−b · sADC) (in the noise-free case). By applying these two different models, we will be able to determine which quantity will most accurately preserve data structure after denoising. The theoretical analysis of the proposed models is presented, together with experimental results and comparisons for denoising synthetic and real HARDI data. PMID:20802839
Yanagisawa, Osamu; Takahashi, Hideyuki; Fukubayashi, Toru
2010-09-01
In this study, we determined the effects of different cooling treatments on exercised muscles. Seven adults underwent four post-exercise treatments (20-min ice-bag application, 60-min gel-pack application at 10 degrees C and 17 degrees C, and non-cooling treatment) with at least 1 week between treatments. Magnetic resonance diffusion- and T2-weighted images were obtained to calculate the apparent diffusion coefficients (apparent diffusion coefficient 1, which reflects intramuscular water diffusion and microcirculation, and apparent diffusion coefficient 2, which is approximately equal to the true diffusion coefficient that excludes as much of the effect of intramuscular microcirculation as possible) and the T2 values (intramuscular water content level) of the ankle dorsiflexors, respectively, before and after ankle dorsiflexion exercise and after post-exercise treatment. The T2 values increased significantly after exercise and returned to pre-exercise values after each treatment; no significant differences were observed among the four post-exercise treatments. Both apparent diffusion coefficients also increased significantly after exercise and decreased significantly after the three cooling treatments; no significant difference was detected among the three cooling treatments. Local cooling suppresses both water diffusion and microcirculation within exercised muscles. Moreover, although the treatment time was longer, adequate cooling effects could be achieved using the gel-pack applications at relatively mild cooling temperatures.
Kyriazi, Stavroula; Blackledge, Matthew; Collins, David J; Desouza, Nandita M
2010-10-01
To compare geometric distortion, signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC), efficacy of fat suppression and presence of artefact between monopolar (Stejskal and Tanner) and bipolar (twice-refocused, eddy-current-compensating) diffusion-weighted imaging (DWI) sequences in the abdomen and pelvis. A semiquantitative distortion index (DI) was derived from the subtraction images with b = 0 and 1,000 s/mm(2) in a phantom and compared between the two sequences. Seven subjects were imaged with both sequences using four b values (0, 600, 900 and 1,050 s/mm(2)) and SNR, ADC for different organs and fat-to-muscle signal ratio (FMR) were compared. Image quality was evaluated by two radiologists on a 5-point scale. DI was improved in the bipolar sequence, indicating less geometric distortion. SNR was significantly lower for all tissues and b values in the bipolar images compared with the monopolar (p < 0.05), whereas FMR was not statistically different. ADC in liver, kidney and sacrum was higher in the bipolar scheme compared to the monopolar (p < 0.03), whereas in muscle it was lower (p = 0.018). Image quality scores were higher for the bipolar sequence (p ≤ 0.025). Artefact reduction makes the bipolar DWI sequence preferable in abdominopelvic applications, although the trade-off in SNR may compromise ADC measurements in muscle.
Ichikawa, Shintaro; Motosugi, Utaroh; Morisaka, Hiroyuki; Sano, Katsuhiro; Ichikawa, Tomoaki; Enomoto, Nobuyuki; Matsuda, Masanori; Fujii, Hideki; Onishi, Hiroshi
2015-07-01
To evaluate the use of intravoxel incoherent motion (IVIM) imaging for staging hepatic fibrosis, and compare its staging ability with that of magnetic resonance elastography (MRE). This study included 129 patients with pathologically staged liver fibrosis, and 53 patients with healthy livers. All patients underwent both MRE and IVIM imaging. Four diffusivity indices were calculated with 11 b-values; slow diffusion coefficient related to molecular diffusion (D), fast diffusion coefficient related to perfusion in micro-vessels (D*), perfusion-related diffusion fraction (f), and apparent diffusion coefficient (ADC). Receiver operating characteristic curve analysis was performed to determine the accuracy of IVIM imaging and MRE for staging hepatic fibrosis. D*, f, and ADC values decreased significantly with fibrosis stage (P < 0.0124), and liver stiffness increased (P < 0.0001). The Az value of MRE was significantly higher than that of D* for all fibrosis stages (D* vs. MRE for ≥ F1, 0.851 vs. 0.992 [P < 0.0001]; ≥ F2, 0.898 vs. 0.998 [P = 0.0003]; ≥ F3, 0.904 vs. 0.995 [P = 0.0004]; F4, 0.885 vs. 0.996 [P < 0.0001]). IVIM imaging is a useful technique for evaluating hepatic fibrosis, but MRE is better able to discriminate fibrosis stages than IVIM imaging. © 2014 Wiley Periodicals, Inc.
Phototransformation Rate Constants of PAHs Associated with Soot Particles
Kim, Daekyun; Young, Thomas M.; Anastasio, Cort
2013-01-01
Photodegradation is a key process governing the residence time and fate of polycyclic aromatic hydrocarbons (PAHs) in particles, both in the atmosphere and after deposition. We have measured photodegradation rate constants of PAHs in bulk deposits of soot particles illuminated with simulated sunlight. The photodegradation rate constants at the surface (k0p), the effective diffusion coefficients (Deff), and the light penetration depths (z0.5) for PAHs on soot layers of variable thickness were determined by fitting experimental data with a model of coupled photolysis and diffusion. The overall disappearance rates of irradiated low molecular weight PAHs (with 2-3 rings) on soot particles were influenced by fast photodegradation and fast diffusion kinetics, while those of high molecular weight PAHs (with 4 or more rings) were apparently controlled by either the combination of slow photodegradation and slow diffusion kinetics or by very slow diffusion kinetics alone. The value of z0.5 is more sensitive to the soot layer thickness than the k0p value. As the thickness of the soot layer increases, the z0.5 values increase, but the k0p values are almost constant. The effective diffusion coefficients calculated from dark experiments are generally higher than those from the model fitting method for illumination experiments. Due to the correlation between k0p and z0.5 in thinner layers, Deff should be estimated by an independent method for better accuracy. Despite some limitations of the model used in this study, the fitted parameters were useful for describing empirical results of photodegradation of soot-associated PAHs. PMID:23247292
Herring, Ronald J
2010-11-30
Unlike some global contentions - abolition of slavery, or universal franchise, for example - the rift over rDNA crops is not about ultimate values. Improvement of farmer welfare and enhanced sustainability of agriculture are universally valued goals. However, means to those ends are politically disputed; that dispute depends on alternative empirical stories about biotechnology, sometimes even alternative epistemologies. Opposition revolves around two fundamental dimensions: bio-safety and bio-property. There is convergence of these dimensions around exceptional risk and vulnerability to corporate control of farmers, but these are analytically separable questions of fact. This paper concentrates on bio-property. Epistemic brokers have successfully established knowledge claims that simultaneously undermine the case for rDNA technologies as potential contributors to development and motivate opposition. Epistemic brokers command authority from their positions at junctures of networks, enabling the screening, weighting, theorizing and diffusion of contentious empirical accounts. In contentions of low information, high information costs and diffuse anxiety, these claims provide cognitive support for opposition to 'GMOs'. Specifically, claims of patents, monopoly corporate control and terminator technology have diffused to and from India in global networks. Though effective in transnational advocacy networks, these claims have proved either false or inconsistent with dynamics on the ground. Copyright © 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Y; Yang, Y; Rangwala, N
Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometricmore » reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10{sup −3}mm{sup 2}/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with excellent geometric fidelity, accurate and highly reproducible ADC measurements was proposed for longitudinal tumor response assessment using an MRI-guided RT system. Yu Gao acknowledges research support from ViewRay.« less
Mundada, Pravin; Varoquaux, Arthur Damien; Lenoir, Vincent; de Vito, Claudio; Dulguerov, Nicolas; Ailianou, Angeliki; Caparrotti, Francesca; Becker, Minerva
2018-04-01
To determine the diagnostic performance of morphologic MRI with diffusion weighted imaging (DWIMRI) for the detection of post-treatment lymph node (LN) recurrence of head and neck squamous cell carcinoma (HNSCC). This retrospective study is based on 33 HNSCC patients who underwent DWIMRI with apparent diffusion coefficient (ADC) measurements for suspected post-treatment loco-regional failure. Two radiologists, blinded to clinical/histopathological data, analyzed MR images according to established morphologic criteria and measured ADC values by drawing regions of interest on each normal/abnormal looking lymph node (LN). Histopathological findings in 40 neck dissections, 133 LN-levels and 755 LNs served as gold standard. Malignant LNs had lower ADCmean values than benign LNs (1.15 ± 0.35 × 10 -3 mm 2 /s versus 1.28 ± 0.28 × 10 -3 mm 2 /s, p = .028). The optimal ADCmean threshold to differentiate malignant from benign LNs was 1.1695 × 10 -3 mm 2 /s. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values (95%CI in parentheses) of DWIMRI with morphologic criteria and ADCmean <1.1695 × 10 -3 mm 2 /s were: (a) 100%(86.2;100), 44.4%(15.3;77.3), 86.1%(69.7;94.7), and 100%(39.5;100) per neck dissection; (b) 83.6%(69.7;92.2), 91.6%(83.0;96.2), 85.4%(71.6;93.4), and 90.5%(81.7;95.5) per LN-level; (c) 53.1%(43.5;62.4), 95.5%(93.5;96.9), 67.4%(56.6;76.7), and 92.0%(89.6;93.9) per LN, respectively. The high NPV of DWIMRI irrespective of analysis type (per neck dissection/per neck level/per lymph node) make it a useful follow-up tool after treatment. Copyright © 2018 Elsevier B.V. All rights reserved.
Han, Xiaowei; Li, Junfeng; Wang, Xiaoyi
2017-04-01
Breast 3.0 T magnetic resonance diffusion-weighted imaging (MR-DWI) of benign and malignant lesions were obtained to measure and calculate the signal-to-noise ratio (SNR), signal intensity ratio (SIR), and contrast-to-noise ratio (CNR) of lesions at different b-values. The variation patterns of SNR and SIR were analyzed with different b-values and the images of DWI were compared at four different b-values with higher image quality. The effect of SIR on the differential diagnostic efficiency of benign and malignant lesions was compared using receiver operating characteristic curves to provide a reference for selecting the optimal b-value. A total of 96 qualified patients with 112 lesions and 14 patients with their contralateral 14 normal breasts were included in this study. The single-shot echo planar imaging sequence was used to perform the DWI and a total of 13 b-values were used: 0, 50, 100, 200, 400, 600, 800, 1000, 1200, 1500, 1800, 2000, and 2500 s/mm 2 . On DWI, the suitable regions of interest were selected. The SNRs of normal breasts (SNR normal ), SNR lesions , SIR, and CNR of benign and malignant lesions were measured on DWI with different b-values and calculated. The variation patterns of SNR, SIR, and CNR values on DWI for normal breasts, benign lesions, and malignant lesions with different b-values were analyzed by using Pearson correlation analysis. The SNR and SIR of benign and malignant lesions with the same b-values were compared using t-tests. The diagnostic efficiencies of SIR with different b-values for benign and malignant lesions were evaluated using receiver operating characteristic curves. Breast DWI had higher CNR for b-values ranging from 600 to 1200 s/mm 2 . It had the best CNR at b = 1000 s/mm 2 for the benign lesions and at b = 1200 s/mm 2 for the malignant lesions. The signal intensity and SNR values of normal breasts decreased with increasing b-values, with a negative correlation (r = -0.945, P < 0.01). The mean SNR values of benign and malignant lesions were negatively correlated (r = -0.982 and -0.947, respectively, and P < 0.01), gradually decreasing with increasing b-values. The mean SIR value of benign lesions gradually decreased with increasing b-values, a negative correlation (r = -0.991, P < 0.01). The mean SIR values of malignant lesions gradually increased with increasing b-values between 0 and 1200 s/mm 2 , and gradually decreased with increasing b-values ≥ 1500 s/mm 2 . For b-values of 600, 800, 1000, and 1200 s/mm 2 , the sensitivity and specificity of SIR in identifying benign and malignant lesions gradually increased with increasing b-values, peaking at 1200 s/mm 2 . Breast DWI had higher image quality for b-values ranging from 600 to 1200 s/mm 2 , and was best for b-values ranging from 1000 to 1200 s/mm 2 . The SIR had the highest diagnostic efficiency in differentiating benign and malignant lesions for a b-value of 1200 s/mm 2 . Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Single-shot turbo spin echo acquisition for in vivo cardiac diffusion MRI.
Edalati, Masoud; Lee, Gregory R; Hui Wang; Taylor, Michael D; Li, Yu Y
2016-08-01
Diffusion MRI offers the ability to noninvasively characterize the microstructure of myocardium tissue and detect disease related pathology in cardiovascular examination. This study investigates the feasibility of in vivo cardiac diffusion MRI under free-breathing condition. A high-speed imaging technique, correlation imaging, is used to enable single-shot turbo spin echo for free-breathing cardiac data acquisition. The obtained in vivo cardiac diffusion-weighted images illustrate robust image quality and minor geometry distortions. The resultant diffusion scalar maps show reliable quantitative values consistent with those previously published in the literature. It is demonstrated that this technique has the potential for in vivo free-breathing cardiac diffusion MRI.
Lee, James T; Liau, Joy; Murphy, Paul; Schroeder, Michael E; Sirlin, Claude B; Bydder, Mark
2012-05-01
The purpose of this study was to investigate the relationship between liver fat fraction (FF) and diffusion parameters derived from the intravoxel incoherent motion (IVIM) model. Thirty-six subjects with suspected nonalcoholic fatty liver disease underwent diffusion-weighted magnetic resonance imaging with 10 b-values and spoiled gradient recalled echo imaging with six echoes for fat quantification. Correlations were measured between FF, transverse relaxivity (R2), diffusivity (D) and perfusion fraction (f). The primary finding was that no significant correlation was obtained for D vs. FF or f vs. FF. Significant correlations were obtained for D vs. R2 (r=-0.490, P=.002) and f vs. D (r=-0.458, P=.005). The conclusion is that hepatic steatosis does not affect measurement of perfusion or diffusion and therefore is unlikely to confound the use of apparent diffusivity to evaluate hepatic fibrosis. Copyright © 2012 Elsevier Inc. All rights reserved.
Parsian, Sana; Giannakopoulos, Nadia V.; Rahbar, Habib; Rendi, Mara H.; Chai, Xiaoyu
2016-01-01
OBJECTIVE To determine the underlying histopathologic features influencing apparent diffusion coefficient (ADC) values of breast fibroadenomas. MATERIALS AND METHODS Biopsy proven fibroadenomas (n=26) initially identified as suspicious on breast MRI were retrospectively evaluated. Histopathological assessments of lesion cellularity and stromal type were compared with ADC measures on diffusion-weighted MRI. RESULTS Presence of epithelial hyperplasia (increased cellularity) and dense collagenous stroma were both significantly associated with lower lesion ADC values (p=0.02 and 0.004, respectively. CONCLUSION Variations in epithelial cellularity and stromal type influence breast lesion ADC values and may explain the wide range of ADC measures observed in benign fibroadenomas. PMID:27379441
NASA Astrophysics Data System (ADS)
Skare, Stefan; Hedehus, Maj; Moseley, Michael E.; Li, Tie-Qiang
2000-12-01
Diffusion tensor mapping with MRI can noninvasively track neural connectivity and has great potential for neural scientific research and clinical applications. For each diffusion tensor imaging (DTI) data acquisition scheme, the diffusion tensor is related to the measured apparent diffusion coefficients (ADC) by a transformation matrix. With theoretical analysis we demonstrate that the noise performance of a DTI scheme is dependent on the condition number of the transformation matrix. To test the theoretical framework, we compared the noise performances of different DTI schemes using Monte-Carlo computer simulations and experimental DTI measurements. Both the simulation and the experimental results confirmed that the noise performances of different DTI schemes are significantly correlated with the condition number of the associated transformation matrices. We therefore applied numerical algorithms to optimize a DTI scheme by minimizing the condition number, hence improving the robustness to experimental noise. In the determination of anisotropic diffusion tensors with different orientations, MRI data acquisitions using a single optimum b value based on the mean diffusivity can produce ADC maps with regional differences in noise level. This will give rise to rotational variances of eigenvalues and anisotropy when diffusion tensor mapping is performed using a DTI scheme with a limited number of diffusion-weighting gradient directions. To reduce this type of artifact, a DTI scheme with not only a small condition number but also a large number of evenly distributed diffusion-weighting gradients in 3D is preferable.
Rechichi, Gilda; Galimberti, Stefania; Signorelli, Mauro; Franzesi, Cammillo Talei; Perego, Patrizia; Valsecchi, Maria Grazia; Sironi, Sandro
2011-07-01
The objective of our study was to investigate whether apparent diffusion coefficient (ADC) values of endometrial cancer differ from those of normal endometrium and myometrium and whether they vary according to histologic tumor grade, the depth of myometrial invasion, or lymph node status. Seventy patients with histologically proved endometrial cancer and 36 control subjects with normal endometrium were enrolled in this prospective study. T2-weighted, dynamic T1-weighted, and diffusion-weighted images with b values of 0 and 1000 s/mm(2) were obtained of all patients. The ADC values of endometrial cancer, normal endometrium, and normal myometrium were recorded. Tumor grade, the depth of myometrial invasion, and lymph node status were assessed at postoperative histopathologic analysis. The mean (± SD) ADC value (10(-3) mm(2)/s) of endometrial cancer (0.77 ± 0.12) was significantly lower than that of normal endometrium (1.31 ± 0.11, p < 0.0001) and normal myometrium (1.52 ± 0.21, p < 0.0001), with no overlap between the two former distributions. There was no significant difference between ADC values of endometrial cancer tissue in patients with tumor grade 1 (0.79 ± 0.08, n = 14), grade 2 (0.76 ± 0.14, n = 40), or grade 3 (0.75 ± 0.12, n = 16) (p = 0.67); in patients with deep (0.77 ± 0.13, n = 18) and those with superficial (0.76 ± 0.12, n = 52) myometrial invasion (p = 0.87); and in patients with (0.78 ± 0.10, n = 6) and those without (0.75 ± 0.14, n = 39) lymph node metastases (p = 0.64). ADC values allow normal endometrium to be differentiated from endometrial carcinoma; however, they do not correlate with histologic tumor grade, the depth of myometrial invasion, or whether lymph node metastases are present.
Teruel, Jose R; Goa, Pål E; Sjøbakk, Torill E; Østlie, Agnes; Fjøsne, Hans E; Bathen, Tone F
2016-11-01
Purpose To evaluate the relative change of the apparent diffusion coefficient (ADC) at low- and medium-b-value regimens as a surrogate marker of microcirculation, to study its correlation with dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) imaging-derived parameters, and to assess its potential for differentiation between malignant and benign breast tumors. Materials and Methods Ethics approval and informed consent were obtained. From May 2013 to June 2015, 61 patients diagnosed with either malignant or benign breast tumors were prospectively recruited. All patients were scanned with a 3-T MR imager, including diffusion-weighted imaging (DWI) and DCE MR imaging. Parametric analysis of DWI and DCE MR imaging was performed, including a proposed marker, relative enhanced diffusivity (RED). Spearman correlation was calculated between DCE MR imaging and DWI parameters, and the potential of the different DWI-derived parameters for differentiation between malignant and benign breast tumors was analyzed by dividing the sample into equally sized training and test sets. Optimal cut-off values were determined with receiver operating characteristic curve analysis in the training set, which were then used to evaluate the independent test set. Results RED had a Spearman rank correlation of 0.61 with the initial area under the curve calculated from DCE MR imaging. Furthermore, RED differentiated cancers from benign tumors with an overall accuracy of 90% (27 of 30) on the test set with 88.2% (15 of 17) sensitivity and 92.3% (12 of 13) specificity. Conclusion This study presents promising results introducing a simplified approach to assess results from a DWI protocol sensitive to the intravoxel incoherent motion effect by using only three b values. This approach could potentially aid in the differentiation, characterization, and monitoring of breast pathologies. © RSNA, 2016 Online supplemental material is available for this article.
Acoustic-noise-optimized diffusion-weighted imaging.
Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M
2015-12-01
This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.
Chang, Hing-Chiu; Hui, Edward S; Chiu, Pui-Wai; Liu, Xiaoxi; Chen, Nan-Kuei
2018-05-01
Three-dimensional (3D) multiplexed sensitivity encoding and reconstruction (3D-MUSER) algorithm is proposed to reduce aliasing artifacts and signal corruption caused by inter-shot 3D phase variations in 3D diffusion-weighted echo planar imaging (DW-EPI). 3D-MUSER extends the original framework of multiplexed sensitivity encoding (MUSE) to a hybrid k-space-based reconstruction, thereby enabling the correction of inter-shot 3D phase variations. A 3D single-shot EPI navigator echo was used to measure inter-shot 3D phase variations. The performance of 3D-MUSER was evaluated by analyses of point-spread function (PSF), signal-to-noise ratio (SNR), and artifact levels. The efficacy of phase correction using 3D-MUSER for different slab thicknesses and b-values were investigated. Simulations showed that 3D-MUSER could eliminate artifacts because of through-slab phase variation and reduce noise amplification because of SENSE reconstruction. All aliasing artifacts and signal corruption in 3D interleaved DW-EPI acquired with different slab thicknesses and b-values were reduced by our new algorithm. A near-whole brain single-slab 3D DTI with 1.3-mm isotropic voxel acquired at 1.5T was successfully demonstrated. 3D phase correction for 3D interleaved DW-EPI data is made possible by 3D-MUSER, thereby improving feasible slab thickness and maximum feasible b-value. Magn Reson Med 79:2702-2712, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Ivancevic, Marko K; Kwee, Thomas C; Takahara, Taro; Ogino, Tetsuo; Hussain, Hero K; Liu, Peter S; Chenevert, Thomas L
2009-11-01
To assess the feasibility of TRacking Only Navigator echo (TRON) for diffusion-weighted magnetic resonance imaging (DWI) of the liver at 3.0T. Ten volunteers underwent TRON, respiratory triggered, and free breathing DWI of the liver at 3.0 Tesla (T). Scan times were measured. Image sharpness, degree of stair-step and stripe artifacts for the three methods were assessed by two observers. Mean scan times of TRON and respiratory triggered DWI relative to free breathing DWI were 34% and 145% longer respectively. In four of eight comparisons (two observers, two b-values, two slice orientations), TRON DWI image sharpness was significantly better than free breathing DWI, but inferior to respiratory triggered DWI. In two of four comparisons (two observers, two b-values), degree of stair-step artifacts in TRON DWI was significantly lower than in respiratory triggered DWI. Degree of stripe artifacts between the three methods was not significantly different. DWI of the liver at 3.0T using TRON is feasible. Image sharpness in TRON DWI is superior to that in free breathing DWI. Although image sharpness of respiratory triggered DWI is still better, TRON DWI requires less scan time and reduces stair-step artifacts.
Qi, Zi-hua; Li, Chuan-fu; Ma, Xiang-xing; Yang, Hui; Jiang, Bao-dong; Zhang, Kai; Yu, De-xin
2012-04-01
To evaluate the value of magnetic resonance dynamic contrast-enhanced (MR-DCE) and magnetic resonance diffusion-weighted imaging (MR-DWI) in the differentiation of benign and malignant musculoskeletal tumors. Sixty-three patients with pathologically confirmed musculoskeletal tumors were examined with MR-DCE and MR-DWI. Using single shot spin echo planar imaging sequence and different b values of 400, 600, 800 and 1000 s/mm(2), we obtained the apparent diffusion coefficient (ADC) of the lesions. ADC values were measured before and after MR-DCE, with a b value of 600 s/mm(2). The 3D fast acquired multiple phase enhanced fast spoiled gradient recalled echo sequence was obtained for multi-slice of the entire lesion. The time-signal intensity curve (TIC), dynamic contrast-enhanced parameters, maximum slope of increase (MSI), positive enhancement integral, signal enhancement ratio, and time to peak (T(peak)) were also recorded. ADC showed no significant difference between benign and malignant tumors when the b value was 400, 600, 800, or 1000 s/mm(2), and it was not significantly different between benign and malignant tumors in both pre-MR-DCE and post-MR-DCE with b value of 600 s/mm(2). TIC were classified into four types type1 showed rapid progression and gradual drainage; type2 showed rapid progression but had no or slight progression; type 3 showed gradual progression; and type 4 had no or slight progression. Most lesions of type1 or type2 were malignant, whereas most lesions of type 3 or type 4 were benign. When using type1 and type 2 as the standards of malignancy, the diagnostic sensitivity and specificity was 87.23% and 50.00%, respectively. The types of TIC showed significant difference between benign and malignant musculoskeletal tumors(χ(2)=17.009,P=0.001). When using MSI 366.62 ± 174.84 as the standard of malignancy, the diagnostic sensitivity and specificity was 86.78% and 78.67%, respectively. When using T(peak)≤70s as the standard of malignancy, the diagnostic sensitivity and specificity was 82.89%and 85.78%, respectively. Positive enhancement integral and signal enhancement ratio showed no significant difference between benign and malignant musculoskeletal tumors. TIC, MSI and T(peak) of MR-DCE are valuable in differentiating benign from malignant musculoskeletal tumors. T(peak) has the highest diagnostic specificity, and TIC has the highest diagnostic sensitivity. The mean ADC value are no significant difference between benign and malignant tumors.
Aksoy, S; Erdil, I; Hocaoglu, E; Inci, E; Adas, G T; Kemik, O; Turkay, R
2018-02-01
The present study indicates that simple and hydatid cysts in liver are a common health problem in Turkey. The aim of the study is to differentiate different types of hydatid cysts from simple cysts by using diffusion-weighted images. In total, 37 hydatid cysts and 36 simple cysts in the liver were diagnosed. We retrospectively reviewed the medical records of the patients who had both ultrasonography and magnetic resonance imaging. We measured apparent diffusion coefficient (ADC) values of all the cysts and then compared the findings. There was no statistically meaningful difference between the ADC values of simple cysts and type 1 hydatid cysts. However, for the other types of hydatid cysts, it is possible to differentiate hydatid cysts from simple cysts using the ADC values. Although in our study we cannot differentiate between type I hydatid cysts and simple cysts in the liver, diffusion-weighted images are very useful to differentiate different types of hydatid cysts from simple cysts using the ADC values.
Holzapfel, Konstantin; Gaa, Jochen; Schubert, Elaine C; Eiber, Matthias; Kleeff, Joerg; Rummeny, Ernst J; Loos, Martin
2016-10-01
To evaluate diffusion-weighted MR imaging (DWI) in the diagnosis of lymph node metastases in patients with cholangiocarcinoma. In 24 patients with cholangiocarcinoma, MR imaging of the upper abdomen was performed prior to surgery at 1.5 T using a respiratory-triggered single-shot echo-planar imaging (SSEPI) sequence (b values: 50, 300, and 600 s/mm(2)). ADC (apparent diffusion coefficient) values and diameters of regional lymph nodes (LN) were determined. Subsequently, in all patients, surgical exploration and/or resection of the primary tumor and regional LN dissection were performed. Imaging results were correlated with results of histopathologic analysis. ADC values and diameters of benign and malignant LN were compared using the Mann-Whitney U test. In addition, a ROC (receiver operating characteristic curve) analysis was performed. The mean ADC value (×10(-3) mm(2)/s) of metastatic LN (1.21 ± 0.15) was significantly lower than that of benign LN (1.62 ± 0.33, p < 0.001) while there was no significant difference in the mean diameter of malignant (16.8 ± 5.4 mm) and benign LN (14.1 ± 4.0 mm; p = 0.09). Using an ADC value of 1.25 × 10(-3) mm(2)/s as threshold, 91.4% of LN were correctly classified as benign or malignant with a sensitivity/specificity of 83.3%/92.8% and a positive/negative predictive value of 66.7%/96.7%. The area under the ROC curve was 0.93. DWI using a respiratory-triggered SSEPI sequence, according to our preliminary experience, is a promising imaging modality in the differentiation of benign and malignant LN in patients with cholangiocarcinoma.
Li, S; Cheng, J; Zhang, Y; Zhang, Z
2015-01-01
Diffusion-weighted MRI (DWI) has been introduced in head and neck lesions and adds important information to the findings obtained through conventional MRI. The purpose of this study was to assess the role of DWI in differentiating benign and malignant lesions of the tongue at 3.0-T field strength imaging. 78 patients with 78 lingual lesions underwent conventional MRI and DWI with b-values of 0 and 1000 s mm(-2) before therapy. The apparent diffusion coefficient (ADC) maps were reconstructed, and the ADC values of the lingual lesions were calculated and compared between benign and malignant lesions of the tongue. The mean ADC values of the malignant tumours, benign solid lesions and cystic lesions were (1.08±0.16)×10(-3), (1.68±0.33)×10(-3) and (2.21±0.35)×10(-3) mm2 s(-1), respectively. The mean ADC values of malignant tumours were significantly lower (p<0.001) than those of benign solid lesions, and the mean ADC values of benign solid lesions were significantly lower (p<0.001) than those of cystic lesions. Receiver operating characteristic analysis showed that when an ADC value<.31×10(-3) mm2 s(-1) was used for predicting malignancy, the highest accuracy of 95.3%, sensitivity of 92.6% and specificity of 97.3% were obtained. ADC values of benign and malignant lesions are significantly different at 3.0-T imaging. DWI can be applied as a complementary tool in the differentiation of benign and malignant lesions of the tongue.
Double-spin-echo diffusion weighting with a modified eddy current adjustment.
Finsterbusch, Jürgen
2010-04-01
Magnetic field inhomogeneities like eddy current-related gradient fields cause geometric distortions in echo-planar imaging (EPI). This in particular affects diffusion-weighted imaging where these distortions vary with the direction of the diffusion weighting and hamper the accurate determination of diffusion parameters. The double-spin-echo preparation often used aims to reduce the cumulative eddy current effect by adjusting the diffusion-weighting gradient pulse durations to the time constant of the dominant eddy current contribution. However, eddy currents with a variety of time constants may be present and cause residual distortions. Here, a modification is proposed where the two bipolar gradient pairs of the preparation are adjusted independently to different time constants. At the expense of a slightly prolonged echo time, residual geometric distortions and correspondingly increased values of the diffusion anisotropy can be reduced as is demonstrated in phantoms and the human brain. Thus, it may help to improve the reliability of diffusion-weighted EPI. Copyright 2010 Elsevier Inc. All rights reserved.
Viehweger, Adrian; Riffert, Till; Dhital, Bibek; Knösche, Thomas R; Anwander, Alfred; Stepan, Holger; Sorge, Ina; Hirsch, Wolfgang
2014-10-01
Diffusion-weighted imaging (DWI) is important in the assessment of fetal brain development. However, it is clinically challenging and time-consuming to prepare neuromorphological examinations to assess real brain age and to detect abnormalities. To demonstrate that the Gini coefficient can be a simple, intuitive parameter for modelling fetal brain development. Postmortem fetal specimens(n = 28) were evaluated by diffusion-weighted imaging (DWI) on a 3-T MRI scanner using 60 directions, 0.7-mm isotropic voxels and b-values of 0, 150, 1,600 s/mm(2). Constrained spherical deconvolution (CSD) was used as the local diffusion model. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) and complexity (CX) maps were generated. CX was defined as a novel diffusion metric. On the basis of those three parameters, the Gini coefficient was calculated. Study of fetal brain development in postmortem specimens was feasible using DWI. The Gini coefficient could be calculated for the combination of the three diffusion parameters. This multidimensional Gini coefficient correlated well with age (Adjusted R(2) = 0.59) between the ages of 17 and 26 gestational weeks. We propose a new method that uses an economics concept, the Gini coefficient, to describe the whole brain with one simple and intuitive measure, which can be used to assess the brain's developmental state.
Marchand, A J; Hitti, E; Monge, F; Saint-Jalmes, H; Guillin, R; Duvauferrier, R; Gambarota, G
2014-11-01
To assess the feasibility of measuring diffusion and perfusion fraction in vertebral bone marrow using the intravoxel incoherent motion (IVIM) approach and to compare two fitting methods, i.e., the non-negative least squares (NNLS) algorithm and the more commonly used Levenberg-Marquardt (LM) non-linear least squares algorithm, for the analysis of IVIM data. MRI experiments were performed on fifteen healthy volunteers, with a diffusion-weighted echo-planar imaging (EPI) sequence at five different b-values (0, 50, 100, 200, 600 s/mm2), in combination with an STIR module to suppress the lipid signal. Diffusion signal decays in the first lumbar vertebra (L1) were fitted to a bi-exponential function using the LM algorithm and further analyzed with the NNLS algorithm to calculate the values of the apparent diffusion coefficient (ADC), pseudo-diffusion coefficient (D*) and perfusion fraction. The NNLS analysis revealed two diffusion components only in seven out of fifteen volunteers, with ADC=0.60±0.09 (10(-3) mm(2)/s), D*=28±9 (10(-3) mm2/s) and perfusion fraction=14%±6%. The values obtained by the LM bi-exponential fit were: ADC=0.45±0.27 (10(-3) mm2/s), D*=63±145 (10(-3) mm2/s) and perfusion fraction=27%±17%. Furthermore, the LM algorithm yielded values of perfusion fraction in cases where the decay was not bi-exponential, as assessed by NNLS analysis. The IVIM approach allows for measuring diffusion and perfusion fraction in vertebral bone marrow; its reliability can be improved by using the NNLS, which identifies the diffusion decays that display a bi-exponential behavior. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Mcdonald, G.
1980-01-01
Black cobalt oxide coatings (high solar absorptance layer) were deposited on thin layers of silver or gold (low emittance layer) which had been previously deposited on oxidized (diffusion barrier layer) stainless steel substrates. The reflectance properties of these coatings were measured at various thicknesses of cobalt for integrated values of the solar and infrared spectrum. The values of absorptance and emittance were calculated from the measured reflectance values, before and after exposure in air at 650 C for approximately 1000 hours. Absorptance and emittance were interdependent functions of the weight of cobalt oxide. Also, these cobalt oxide/noble metal/oxide diffusion barrier coatings have absorptances greater than 0.90 and emittances of approximately 0.20 even after about 1000 hours at 650 C.
Tan, Yan; Zhang, Hui; Wang, Xiao-Chun; Qin, Jiang-Bo; Wang, Le
2018-06-01
To investigate the value of multi-ultrahigh-b-value diffusion-weighted imaging (UHBV-DWI) in differentiating high-grade astrocytomas (HGAs) from low-grade astrocytomas (LGAs), analyze its association with aquaporin (AQP) expression. 40 astrocytomas divided into LGAs (N = 15) and HGAs (N = 25) were studied. Apparent diffusion coefficient (ADC) and UHBV-ADC values in solid parts and peritumoral edema were compared between LGAs and HGAs groups by the t-test. Using receiver operating characteristic curves to identify the better parameter. Using real time polymerase chain reaction to assess AQP messenger ribonucleic acid (mRNA). Using spearman correlation analysis to assess the correlation of AQP mRNA with each parameter. ADC values in solid parts of HGAs were significantly lower than LGAs (p = 0.02), while UHBV-ADC values of HGAs were significantly higher than LGAs (p < 0.01). Area under the curve (AUC) of UHBV-ADC (0.810) was larger than ADC (0.713), and the area under the curve of UHBV-ADC was significantly higher than that of ADC (p = 0.041). AQP4 mRNA was significantly higher in HGAs than that in LGAs (p < 0.01); there was less AQP9 mRNA and no AQP1 mRNA in LGAs and HGAs groups (p > 0.05); ADC value showed a negative correlation with AQP4 mRNA (r = -0.357; p = 0.024). UHBV-ADC value positively correlated with the AQP4 mRNA (r = 0.646; p < 0.01). UHBV-DWI allowed for a more accurate grading of cerebral astrocytoma than DWI, and UHBV-ADC value may be related with the AQP4 mRNA levels. UHBV-DWI could be of value in the assessment of astrocytoma. Advances in knowledge: UHBV-DWI generated by multi UHBV could have particular value for astrocytoma grading, and the level of AQP4 mRNA might be potentially linked to the change of UHBV-DWI parameter, and we might find the exact reason for the difference of UHBV-ADC between the LGAs and HGAs.
A quantitative comparison of two methods to correct eddy current-induced distortions in DT-MRI.
Muñoz Maniega, Susana; Bastin, Mark E; Armitage, Paul A
2007-04-01
Eddy current-induced geometric distortions of single-shot, diffusion-weighted, echo-planar (DW-EP) images are a major confounding factor to the accurate determination of water diffusion parameters in diffusion tensor MRI (DT-MRI). Previously, it has been suggested that these geometric distortions can be removed from brain DW-EP images using affine transformations determined from phantom calibration experiments using iterative cross-correlation (ICC). Since this approach was first described, a number of image-based registration methods have become available that can also correct eddy current-induced distortions in DW-EP images. However, as yet no study has investigated whether separate eddy current calibration or image-based registration provides the most accurate way of removing these artefacts from DT-MRI data. Here we compare how ICC phantom calibration and affine FLIRT (http://www.fmrib.ox.ac.uk), a popular image-based multi-modal registration method that can correct both eddy current-induced distortions and bulk subject motion, perform when registering DW-EP images acquired with different slice thicknesses (2.8 and 5 mm) and b-values (1000 and 3000 s/mm(2)). With the use of consistency testing, it was found that ICC was a more robust algorithm for correcting eddy current-induced distortions than affine FLIRT, especially at high b-value and small slice thickness. In addition, principal component analysis demonstrated that the combination of ICC phantom calibration (to remove eddy current-induced distortions) with rigid body FLIRT (to remove bulk subject motion) provided a more accurate registration of DT-MRI data than that achieved by affine FLIRT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karki, K; Hugo, G; Ford, J
2014-06-15
Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADC IVIM) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm andmore » 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADC IVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADC IVIM, perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADC IVIM(p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADC IVIM, respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADC IVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets (250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2}) approached ADC IVIM, with relative noise comparable to that of ADC IVIM. These sets may be used to obtain perfusion-insensitive ADC values in lung tumors. E. Weiss: Funding through Varian Medical Systems and Philips Oncology Systems, UpToDate royalties. G. Hugo: NIH R01CA166119, P01 CA116602, NHMRC Project Grant.« less
Bae, Hyeyeol; Yoshida, Soichiro; Matsuoka, Yoh; Nakajima, Hiroshi; Ito, Eisaku; Tanaka, Hiroshi; Oya, Miyako; Nakayama, Takayuki; Takeshita, Hideki; Kijima, Toshiki; Ishioka, Junichiro; Numao, Noboru; Koga, Fumitaka; Saito, Kazutaka; Akashi, Takumi; Fujii, Yasuhisa; Kihara, Kazunori
2014-03-01
To assess whether there is an association between the apparent diffusion coefficient (ADC) value and the pathological characteristics of prostate cancer. The study cohort consisted of 29 consecutive patients with prostate cancer treated with radical prostatectomy. All patients underwent diffusion-weighted MRI before the prostate biopsy. In 42 tumor foci, the associations of the ADC values with the clinicopathological characteristics and Ki-67 labeling index (LI) were analyzed. High-grade cancers (Gleason score [GS] ≥ 4 + 3), larger cancers (maximum diameter (MD) ≥ 16 mm), and highly proliferating cancers (Ki-67 LI ≥ 4.43 %) had significantly lower ADC values, respectively (P < .001, P = .008, and P = .044, respectively). There was no significant difference in ADC value according to age, prostate-specific antigen, presence of extra-prostatic extension, and intra-tumoral stroma proportion. Multivariate analysis showed that GS, Ki-67 LI, and MD had independent and significant correlations with ADC value (P < .001, P = .006, and P = .002, respectively). Low ADC tumors (<0.52 × 10(-3) mm(2)/s) are likely to be high-grade cancer foci compared with high ADC tumors (relative risk: 65.2). The sensitivity and specificity of the ADC value to predict high-grade cancer foci are 81.8 and 93.5 %, respectively. A low ADC value reflects the morphological and biological features of prostate cancer. Analyzing the ADC value may make it possible to more precisely predict the cancer aggressiveness of each focus before treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeng, Q.-S.; Li, C.-F.; Liu Hong
2007-05-01
Purpose: The aim of this study was to explore the diagnostic effectiveness of magnetic resonance (MR) spectroscopy with diffusion-weighted imaging on the evaluation of the recurrent contrast-enhancing areas at the site of treated gliomas. Methods and Materials: In 55 patients who had new contrast-enhancing lesions in the vicinity of the previously resected and irradiated high-grade gliomas, two-dimensional MR spectroscopy and diffusion-weighted imaging were performed. Spectral data for N-acetylaspartate (NAA), choline (Cho), creatine (Cr), lipid (Lip), and lactate (Lac) were analyzed in conjunction with the apparent diffusion coefficient (ADC) in all patients. Diagnosis of these lesions was assigned by means ofmore » follow-up or histopathology. Results: The Cho/NAA and Cho/Cr ratios were significantly higher in recurrent tumor than in regions of radiation injury (p < 0.01). The ADC value and ADC ratios (ADC of contrast-enhancing lesion to matching structure in the contralateral hemisphere) were significantly higher in radiation injury regions than in recurrent tumor (p < 0.01). With MR spectroscopic data, two variables (Cho/NAA and Cho/Cr ratios) were shown to differentiate recurrent glioma from radiation injury, and 85.5% of total subjects were correctly classified into groups. However, with discriminant analysis of MR spectroscopy imaging plus diffusion-weighted imaging, three variables (Cho/NAA, Cho/Cr, and ADC ratio) were identified and 96.4% of total subjects were correctly classified. There was a significant difference between the diagnostic accuracy of the two discriminant analyses (Chi-square = 3.96, p = 0.046). Conclusion: Using discriminant analysis, this study found that MR spectroscopy in combination with ADC ratio, rather than ADC value, can improve the ability to differentiate recurrent glioma and radiation injury.« less
Liu, Xiaohang; Zhou, Liangping; Peng, Weijun; Wang, He; Zhang, Yong
2015-10-01
To compare stretched-exponential and monoexponential model diffusion-weighted imaging (DWI) in prostate cancer and normal tissues. Twenty-seven patients with prostate cancer underwent DWI exam using b-values of 0, 500, 1000, and 2000 s/mm(2) . The distributed diffusion coefficients (DDC) and α values of prostate cancer and normal tissues were obtained with stretched-exponential model and apparent diffusion coefficient (ADC) values using monoexponential model. The ADC, DDC (both in 10(-3) mm(2)/s), and α values (range, 0-1) were compared among different prostate tissues. The ADC and DDC were also compared and correlated in each tissue, and the standardized differences between DDC and ADC were compared among different tissues. Data were obtained for 31 cancers, 36 normal peripheral zone (PZ) and 26 normal central gland (CG) tissues. The ADC (0.71 ± 0.12), DDC (0.60 ± 0.18), and α value (0.64 ± 0.05) of tumor were all significantly lower than those of the normal PZ (1.41 ± 0.22, 1.47 ± 0.20, and 0.85 ± 0.09) and CG (1.25 ± 0.14, 1.32 ± 0.13, and 0.82 ± 0.06) (all P < 0.05). ADC was significantly higher than DDC in cancer, but lower than DDC in the PZ and CG (all P < 0.05). The ADC and DDC were strongly correlated (R(2) = 0.99, 0.98, 0.99, respectively, all P < 0.05) in all the tissue, and standardized difference between ADC and DDC of cancer was slight but significantly higher than that in normal tissue. The stretched-exponential model DWI provides more parameters for distinguishing prostate cancer and normal tissue and reveals slight differences between DDC and ADC values. © 2015 Wiley Periodicals, Inc.
Preliminary diffusion tensor imaging studies in limb-girdle muscular dystrophies
NASA Astrophysics Data System (ADS)
Hidalgo-Tobon, S.; Hernandez-Salazar, G.; Vargas-Cañas, S.; Marrufo-Melendez, O.; Solis-Najera, S.; Taboada-Barajas, J.; Rodriguez, A. O.; Delgado-Hernandez, R.
2012-10-01
Limb-girdle muscular dystrophies (LGMD) are a group of autosomal dominantly or recessively inherited muscular dystrophies that also present with primary proximal (limb-girdle) muscle weakness. This type of dystrophy involves the shoulder and pelvic girdles, distinct phenotypic or clinical characteristics are recognized. Imaging experiments were conducted on a 1.5T GE scanner (General Electric Medical Systems. Milwaukee. USA), using a combination of two eight-channel coil array. Diffusion Tensor Imaging (DTI) data were acquired using a SE-EPI sequence, diffusion weighted gradients were applied along 30 non-collinear directions with a b-value=550 s/mm2. The connective tissue content does not appear to have a significant effect on the directionality of the diffusion, as assessed by fractional anisotropy. The fibers of the Sartorius muscle and gracilis showed decreased number of tracts, secondary to fatty infiltration and replacement of connective tissue and muscle mass loss characteristic of the underlying pathology. Our results demonstrated the utility of non-invasive MRI techniques to characterize the muscle pathology, through quantitative and qualitative methods such as the FA values and tractrography.
Li, Xiang; Qu, Jin-Rong; Luo, Jun-Peng; Li, Jing; Zhang, Hong-Kai; Shao, Nan-Nan; Kwok, Keith; Zhang, Shou-Ning; Li, Yan-le; Liu, Cui-Cui; Zee, Chi-Shing; Li, Hai-Liang
2014-09-01
To determine the effect of intravenous administration of gadolinium (Gd) contrast medium (Gd-DTPA) on diffusion-weighted imaging (DWI) for the evaluation of normal brain parenchyma vs. brain tumor following a short temporal interval. Forty-four DWI studies using b values of 0 and 1000 s/mm(2) were performed before, immediately after, 1 min after, 3 min after, and 5 min after the administration of Gd-DTPA on 62 separate lesions including 15 meningioma, 17 glioma and 30 metastatic lesions. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) values of the brain tumor lesions and normal brain tissues were measured on pre- and postcontrast images. Statistical analysis using paired t-test between precontrast and postcontrast data were obtained on three brain tumors and normal brain tissue. The SNR and CNR of brain tumors and the SNR of normal brain tissue showed no statistical differences between pre- and postcontrast (P > 0.05). The ADC values on the three cases of brain tumors demonstrated significant initial increase on the immediate time point (P < 0.01) and decrease on following the 1 min time point (P < 0.01) after contrast. Significant decrease of ADC value was still found at 3min and 5min time point in the meningioma group (P < 0.01) with gradual normalization over time. The ADC values of normal brain tissues demonstrated significant initial elevation on the immediately postcontrast DWI sequence (P < 0.01). Contrast medium can cause a slight but statistically significant change on the ADC value within a short temporal interval after the contrast administration. The effect is both time and lesion-type dependent. © 2013 Wiley Periodicals, Inc.
Sepahdari, Ali R; Aakalu, Vinay K; Setabutr, Pete; Shiehmorteza, Masoud; Naheedy, John H; Mafee, Mahmood F
2010-08-01
To determine whether magnetic resonance (MR) imaging with diffusion-weighted (DW) imaging can help discriminate between radiologically indeterminate benign and malignant orbital masses and to identify optimal apparent diffusion coefficient (ADC) thresholds for such discrimination. Informed consent was waived for this HIPAA-compliant institutional review board-approved retrospective study. Forty-seven orbital masses imaged with echo-planar DW imaging were identified in 47 patients (25 female patients, 22 male patients; average age, 35 years). A fellowship-trained orbital surgeon determined reference-standard diagnoses on the basis of chart review, and a neuroradiology fellow and senior neuroradiologist who were blinded to the diagnoses selected a region of interest for each lesion by consensus. ADC was calculated from signal intensity on DW images obtained with b = 1000 and b = 0 sec/mm(2). Lesion ADC was also compared with that of normal-appearing white matter (ADC ratio). The Student t test was used to compare groups. Receiver operating characteristic analysis was performed. Intraobserver agreement was assessed with a repeat data collection. Malignant lesions had lower ADCs than benign lesions, irrespective of patient age (P < .02) and in adults specifically (P < .05). Lymphomas had lower ADCs than pseudotumors (P < .001). An ADC of less than 1.0 x 10(-3) mm(2)/sec and an ADC ratio of less than 1.2 were optimal for predicting malignancy (sensitivity, 63% for both; specificity, 84% and 90%, respectively; and accuracy, 77% and 81%, respectively). Lymphoma was differentiated from pseudotumor with 100% accuracy (in 16 of 16 cases) by using these values. Infiltrative lesions that were hypointense on T2-weighted images were better characterized with DW imaging than lesions that were hyperintense or well defined. Echo-planar DW MR imaging can help characterize indeterminate orbital masses.
Attenberger, Ulrike I; Runge, Val M; Stemmer, Alto; Williams, Kenneth D; Naul, L Gill; Michaely, Henrik J; Schoenberg, Stefan O; Reiser, Maximilian F; Wintersperger, Bernd J
2009-10-01
To evaluate the signal-to-noise ratio (SNR) and diagnostic quality of diffusion weighted imaging (DWI) using a fast spin echo (FSE) sequence with BLADE k-space trajectory at 3 T in combination with a 32-channel head coil. The scan was compared with a standard spin echo (SE) echo-planar imaging (EPI) DWI and a high resolution SE EPI DWI sequence. Fourteen patients with acute brain ischemia were included in this Institutional Review Board approved study. All patients were evaluated with 3 different image sequences, using a 3 T scanner and a 32-channel head coil: (a) a standard SE EPI DWI (matrix size 192 x 192), (b) a high resolution SE EPI DWI (matrix size of 256 x 256) and (c) a FSE DWI BLADE (matrix size 192 x 192). The SNR of the 3 scans was compared in 10 healthy volunteers by a paired student t test. Image quality was evaluated with 4 dedicated questions in a blinded read: (1) The scans were ranked in terms of bulk susceptibility artifact. (2) The scan preference for diagnosis of any diffusion abnormality that might occur and (3) the preference for visualization of the diffusion abnormality actually present was determined. (4) The influence of bulk susceptibility on image evaluation for the diffusion abnormality present was assessed. For visualization of the diffusion abnormality present, BLADE DWI was the scan sequence preferred most by both readers (reader 1: 41.7%, reader 2: 35.7%). For visualization of any diffusion abnormality present, BLADE DWI was the preferred scan in 13 of 14 cases for reader 1 (93%) and in 11 of 14 cases for reader 2 (78.6%). No high resolution SE EPI DWI scan was rated best by reader 1. Reader 2 rated the high resolution SE EPI DWI scan superior in only 1 of 56 judgments. The standard EPI DWI sequence (21.8 +/- 5.3) had in comparison to the high resolution EPI DWI (11.9 +/- 2.6) and the BLADE DWI scans (11.3 +/- 3.8) significantly higher SNR mean values. Our preliminary data demonstrates the feasibility of a FSE EPI DWI scan with radial-like k-space sampling, using a 32-channel coil at 3 T in acute brain ischemia. The BLADE DWI was the preferred scan for the detection of acute diffusion abnormalities because of the lack of bulk susceptibility artifacts.
IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T
Cui, Yong; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Taouli, Bachir
2015-01-01
Purpose To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p = 0.006–0.020), except for b0 (p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T (p = 0.005–0.044), except for ADC (p = 0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). Conclusion Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. PMID:26393236
NASA Astrophysics Data System (ADS)
Jerome, N. P.; d'Arcy, J. A.; Feiweier, T.; Koh, D.-M.; Leach, M. O.; Collins, D. J.; Orton, M. R.
2016-12-01
The bi-exponential intravoxel-incoherent-motion (IVIM) model for diffusion-weighted MRI (DWI) fails to account for differential T 2 s in the model compartments, resulting in overestimation of pseudodiffusion fraction f. An extended model, T2-IVIM, allows removal of the confounding echo-time (TE) dependence of f, and provides direct compartment T 2 estimates. Two consented healthy volunteer cohorts (n = 5, 6) underwent DWI comprising multiple TE/b-value combinations (Protocol 1: TE = 62-102 ms, b = 0-250 mm-2s, 30 combinations. Protocol 2: 8 b-values 0-800 mm-2s at TE = 62 ms, with 3 additional b-values 0-50 mm-2s at TE = 80, 100 ms scanned twice). Data from liver ROIs were fitted with IVIM at individual TEs, and with the T2-IVIM model using all data. Repeat-measures coefficients of variation were assessed for Protocol 2. Conventional IVIM modelling at individual TEs (Protocol 1) demonstrated apparent f increasing with longer TE: 22.4 ± 7% (TE = 62 ms) to 30.7 ± 11% (TE = 102 ms) T2-IVIM model fitting accounted for all data variation. Fitting of Protocol 2 data using T2-IVIM yielded reduced f estimates (IVIM: 27.9 ± 6%, T2-IVIM: 18.3 ± 7%), as well as T 2 = 42.1 ± 7 ms, 77.6 ± 30 ms for true and pseudodiffusion compartments, respectively. A reduced Protocol 2 dataset yielded comparable results in a clinical time frame (11 min). The confounding dependence of IVIM f on TE can be accounted for using additional b/TE images and the extended T2-IVIM model.
Helmer, K G; Chou, M-C; Preciado, R I; Gimi, B; Rollins, N K; Song, A; Turner, J; Mori, S
2016-02-27
It is now common for magnetic-resonance-imaging (MRI) based multi-site trials to include diffusion-weighted imaging (DWI) as part of the protocol. It is also common for these sites to possess MR scanners of different manufacturers, different software and hardware, and different software licenses. These differences mean that scanners may not be able to acquire data with the same number of gradient amplitude values and number of available gradient directions. Variability can also occur in achievable b-values and minimum echo times. The challenge of a multi-site study then, is to create a common protocol by understanding and then minimizing the effects of scanner variability and identifying reliable and accurate diffusion metrics. This study describes the effect of site, scanner vendor, field strength, and TE on two diffusion metrics: the first moment of the diffusion tensor field (mean diffusivity, MD), and the fractional anisotropy (FA) using two common analyses (region-of-interest and mean-bin value of whole brain histograms). The goal of the study was to identify sources of variability in diffusion-sensitized imaging and their influence on commonly reported metrics. The results demonstrate that the site, vendor, field strength, and echo time all contribute to variability in FA and MD, though to different extent. We conclude that characterization of the variability of DTI metrics due to site, vendor, field strength, and echo time is a worthwhile step in the construction of multi-center trials.
Deng, Yi; Yang, Biran; Peng, Yan; Liu, Zhiqiang; Luo, Jinwen; Du, Guoxin
2018-03-14
The purpose of the study was to examine differences in kidney intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) parameters in early-stage diabetic patients versus healthy controls. Nineteen type 2 diabetic patients (group A) with a urinary albumin-to-creatinine ratio (ACR) < 30 mg/g and an estimated glomerular filtration rate (eGFR) of 80-120 mL/(min 1.73 m 2 ) and twelve healthy volunteers (group B) were recruited. Kidneys were scanned with 1.5-Tesla IVIM-DWI. Nine b values (0, 50, 100, 150, 200, 300, 400, 600, and 800 s/mm 2 ) were used. The parameters derived from IVIM-DWI were calculated for each kidney by two radiologists and included the perfusion fraction (f), diffusion coefficient (D), and pseudo-diffusion coefficient (D*). The mean values of f, D, and D* were calculated by selecting multiple regions of interest in the kidney. The diagnostic performance of the f, D, and D* values for the diagnosis of early diabetic kidney changes was determined by receiver operating characteristic analysis. Three radiologists independently measured the parameters derived from IVIM-DWI in the two groups by free-hand placing regions of interest, and the interclass coefficients (ICCs) were analyzed by SPSS.16.0 software. The f values of the kidneys were significantly higher in diabetic patients than in healthy volunteers. The D value of the kidneys was significantly lower in diabetic patients than in healthy volunteers. No significant differences in the D* values of the kidneys were observed between diabetic patients and healthy volunteers. The D values of the right kidneys were significantly higher than those of the left kidneys in both groups. The results of the receiver operating characteristic analysis were as follows: left kidney-f value AUC = 0.650 (cutoff point ≥ 27.49%) and D value AUC = 0.752 (cutoff point ≤ 1.68 × 10 -3 mm 2 /s); and right kidney-f value AUC = 0.650 (cutoff point ≥ 28.24%) and D value AUC = 0.752 (cutoff point ≤ 1.81 × 10 -3 mm 2 /s). The diagnostic performance of the D* value was very low (AUC < 0.6). No significant differences were present between the areas under the curves of the f and D values (P > 0.05). The ICCs of the f value and D value were between 0.637 and 0.827. The ICC of the D* value was less than 0.3. The results of our study suggest that changes in kidneys detected by IVIM-DWI may serve as indicators of early diabetic kidney disease.
Kartalis, Nikolaos; Loizou, Louiza; Edsborg, Nick; Segersvärd, Ralf; Albiin, Nils
2012-10-01
To compare respiratory-triggered, free-breathing, and breath-hold DWI techniques regarding (1) image quality, and (2) signal intensity (SI) and ADC measurements in pancreatic ductal adenocarcinoma (PDAC). Fifteen patients with histopathologically proven PDAC underwent DWI prospectively at 1.5 T (b = 0, 50, 300, 600 and 1,000 s/mm(2)) with the three techniques. Two radiologists, independently and blindly, assigned total image quality scores [sum of rating diffusion images (lesion detection, anatomy, presence of artefacts) and ADC maps (lesion characterisation, overall image quality)] per technique and ranked them. The lesion SI, signal-to-noise ratio, mean ADC and coefficient of variation (CV) were compared. Total image quality scores for respiratory-triggered, free-breathing and breath-hold techniques were 17.9, 16.5 and 17.1 respectively (respiratory-triggered was significantly higher than free-breathing but not breath-hold). The respiratory-triggered technique had a significantly higher ranking. Lesion SI on all b-values and signal-to-noise ratio on b300 and b600 were significantly higher for the respiratory-triggered technique. For respiratory-triggered, free-breathing and breath-hold techniques the mean ADCs were 1.201, 1.132 and 1.253 × 10(-3) mm(2)/s, and mean CVs were 8.9, 10.8 and 14.1 % respectively (respiratory-triggered and free-breathing techniques had a significantly lower mean CV than the breath-hold technique). In both analyses, respiratory-triggered DWI showed superiority and seems the optimal DWI technique for demonstrating PDAC. • Diffusion-weighted magnetic resonance imaging is increasingly used to detect pancreatic cancer • Images are acquired using various breathing techniques and multiple b-values • Breathing techniques used: respiratory-triggering, free-breathing and breath-hold • Respiratory-triggering seems the optimal breathing technique for demonstrating pancreatic cancer.
Hara, Tomohiko; Nakanishi, Hiroyuki; Nakagawa, Tohru; Komiyama, Motokiyo; Kawahara, Takashi; Manabe, Tomoko; Miyake, Mototaka; Arai, Eri; Kanai, Yae; Fujimoto, Hiroyuki
2013-10-01
Recent studies have shown an improvement in prostate cancer diagnosis with the use of 3.0-Tesla magnetic resonance imaging. We retrospectively assessed the ability of this imaging technique to predict side-specific extracapsular extension of prostate cancer. From October 2007 to August 2011, prostatectomy was carried out in 396 patients after preoperative 3.0-Tesla magnetic resonance imaging. Among these, 132 (primary sample) and 134 patients (validation sample) underwent 12-core prostate biopsy at the National Cancer Center Hospital of Tokyo, Japan, and at other institutions, respectively. In the primary dataset, univariate and multivariate analyses were carried out to predict side-specific extracapsular extension using variables determined preoperatively, including 3.0-Tesla magnetic resonance imaging findings (T2-weighted and diffusion-weighted imaging). A prediction model was then constructed and applied to the validation study sample. Multivariate analysis identified four significant independent predictors (P < 0.05), including a biopsy Gleason score of ≥8, positive 3.0-Tesla diffusion-weighted magnetic resonance imaging findings, ≥2 positive biopsy cores on each side and a maximum percentage of positive cores ≥31% on each side. The negative predictive value was 93.9% in the combination model with these four predictors, meanwhile the positive predictive value was 33.8%. Good reproducibility of these four significant predictors and the combination model was observed in the validation study sample. The side-specific extracapsular extension prediction by the biopsy Gleason score and factors associated with tumor location, including a positive 3.0-Tesla diffusion-weighted magnetic resonance imaging finding, have a high negative predictive value, but a low positive predictive value. © 2013 The Japanese Urological Association.
2015-01-15
isoprene determined by 1H NMR of each copolymer. Hydration Macromolecules Article DOI: 10.1021/ma502362a Macromolecules XXXX, XXX, XXX−XXX B number (λ) is...C. This is attributed to the decomposition of the TMA groups. Slight weight loss at lower temperatures is presumably due to the loss of trapped water...that at sufficiently high hydration levels the diffusion coefficient of ions approach their dilute solution diffusivity limits.30 Since conductivity is
Enhanced diffusion weighting generated by selective adiabatic pulse trains
NASA Astrophysics Data System (ADS)
Sun, Ziqi; Bartha, Robert
2007-09-01
A theoretical description and experimental validation of the enhanced diffusion weighting generated by selective adiabatic full passage (AFP) pulse trains is provided. Six phantoms (Ph-1-Ph-6) were studied on a 4 T Varian/Siemens whole body MRI system. Phantoms consisted of 2.8 cm diameter plastic tubes containing a mixture of 10 μm ORGASOL polymer beads and 2 mM Gd-DTPA dissolved in 5% agar (Ph-1) or nickel(II) ammonium sulphate hexahydrate doped (56.3-0.8 mM) water solutions (Ph-2-Ph-6). A customized localization by adiabatic selective refocusing (LASER) sequence containing slice selective AFP pulse trains and pulsed diffusion gradients applied in the phase encoding direction was used to measure 1H 2O diffusion. The b-value associated with the LASER sequence was derived using the Bloch-Torrey equation. The apparent diffusion coefficients measured by LASER were comparable to those measured by a conventional pulsed gradient spin-echo (PGSE) sequence for all phantoms. Image signal intensity increased in Ph-1 and decreased in Ph-2-Ph-6 as AFP pulse train length increased while maintaining a constant echo-time. These experimental results suggest that such AFP pulse trains can enhance contrast between regions containing microscopic magnetic susceptibility variations and homogeneous regions in which dynamic dephasing relaxation mechanisms are dominant.
Detailed magnetic resonance imaging features of a case series of primary gliosarcoma.
Sampaio, Luísa; Linhares, Paulo; Fonseca, José
2017-12-01
Objective We aimed to characterise the magnetic resonance imaging (MRI) features of a case series of primary gliosarcoma, with the inclusion of diffusion-weighted imaging and perfusion imaging with dynamic susceptibility contrast MRI. Materials and methods We conducted a retrospective study of cases of primary gliosarcoma from the Pathology Department database from January 2006 to December 2014. Clinical and demographic data were obtained. Two neuroradiologists, blinded to diagnosis, assessed tumour location, signal intensity in T1 and T2-weighted images, pattern of enhancement, diffusion-weighted imaging and dynamic susceptibility contrast MRI studies on preoperative MRI. Results Seventeen patients with primary gliosarcomas had preoperative MRI study: seven men and 10 women, with a mean age of 59 years (range 27-74). All lesions were well demarcated, supratentorial and solitary (frontal n = 5, temporal n = 4, parietal n = 3); 13 tumours abutted the dural surface (8/13 with dural enhancement); T1 and T2-weighted imaging patterns were heterogeneous and the majority of lesions (12/17) showed a rim-like enhancement pattern with focal nodularities/irregular thickness. Restricted diffusion (mean apparent diffusion coefficient values 0.64 × 10 -3 mm 2 /s) in the more solid/thick components was present in eight out of 11 patients with diffusion-weighted imaging study. Dynamic susceptibility contrast MRI study ( n = 8) consistently showed hyperperfusion in non-necrotic/cystic components on relative cerebral volume maps. Conclusions The main distinguishing features of primary gliosarcoma are supratentorial and peripheral location, well-defined boundaries and a rim-like pattern of enhancement with an irregular thick wall. Diffusion-weighted imaging and relative cerebral volume map analysis paralleled primary gliosarcoma with high-grade gliomas, thus proving helpful in differential diagnosis.
Filli, Lukas; Wurnig, Moritz; Nanz, Daniel; Luechinger, Roger; Kenkel, David; Boss, Andreas
2014-12-01
Diffusion kurtosis imaging (DKI) is based on a non-Gaussian diffusion model that should inherently better account for restricted water diffusion within the complex microstructure of most tissues than the conventional diffusion-weighted imaging (DWI), which presumes Gaussian distributed water molecule displacement probability. The aim of this investigation was to test the technical feasibility of in vivo whole-body DKI, probe for organ-specific differences, and compare whole-body DKI and DWI results. Eight healthy subjects underwent whole-body DWI on a clinical 3.0 T magnetic resonance imaging system. Echo-planar images in the axial orientation were acquired at b-values of 0, 150, 300, 500, and 800 mm²/s. Parametrical whole-body maps of the diffusion coefficient (D), the kurtosis (K), and the traditional apparent diffusion coefficient (ADC) were generated. Goodness of fit was compared between DKI and DWI fits using the sums of squared residuals. Data groups were tested for significant differences of the mean by paired Student t tests. Good-quality parametrical whole-body maps of D, K, and ADC could be computed. Compared with ADC values, D values were significantly higher in the cerebral gray matter (by 30%) and white matter (27%), renal cortex (23%) and medulla (21%), spleen (101%), as well as erector spinae muscle (34%) (each P value <0.001). No significant differences between D and ADC were found in the cerebrospinal fluid (P = 0.08) and in the liver (P = 0.13). Curves of DKI fitted the measurement points significantly better than DWI curves did in most organs. Whole-body DKI is technically feasible and may reflect tissue microstructure more meaningfully than whole-body DWI.
Augmentation of oxygen transport by various hemoglobins as determined by pulsed field gradient NMR.
Budhiraja, Vikas; Hellums, J David; Post, Jan F M
2002-11-01
Diffusion of oxyhemoglobin has been shown to augment the oxygen transport inside the red blood cells. Measurement of hemoglobin diffusion coefficients by pulsed-field gradient (PFG) nuclear magnetic resonance (NMR) technique can be used for estimating this augmentation effect. Self-diffusion coefficients of polymerized and unpolymerized bovine hemoglobin (Hb) and several other proteins were measured using this technique. The Hb diffusion coefficient was used to determine the effective permeability of oxygen and augmentation of oxygen transport through samples of Hb solutions due to diffusion of oxyhemoglobin. The values compared well with our previous diffusion cell measurements of effective diffusivity and augmentation. Our NMR studies show that even at low concentrations the augmentation of oxygen transport due to diffusion can be significant. The PFG NMR technique can thus provide an accurate and easy method for measuring augmentation of oxygen transport, especially in dilute samples of Hb. The results on polyhemoglobin and high-molecular-weight hemoglobin are of both basic interest and practical value in assessing the promise and performance of hemoglobin-based blood substitutes.
Cavalleri, Francesca; Lugli, Licia; Pugliese, Marisa; D'Amico, Roberto; Todeschini, Alessandra; Della Casa, Elisa; Gallo, Claudio; Frassoldati, Rossella; Ferrari, Fabrizio
2014-09-01
The diagnostic and prognostic assessment of newborn infants with hypoxic-ischemic encephalopathy (HIE) comprises, among other tools, diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps. To compare the ability of DWI and ADC maps in newborns with HIE to predict the neurodevelopmental outcome at 2 years of age. Thirty-four term newborns with HIE admitted to the Neonatal Intensive Care Unit of Modena University Hospital from 2004 to 2008 were consecutively enrolled in the study. All newborns received EEG, conventional MRI and DWI within the first week of life. DWI was analyzed by means of summation (S) score and regional ADC measurements. Neurodevelopmental outcome was assessed with a standard 1-4 scale and the Griffiths Mental Developmental Scales - Revised (GMDS-R). When the outcome was evaluated with a standard 1-4 scale, the DWI S scores showed very high area under the curve (AUC) (0.89) whereas regional ADC measurements in specific subregions had relatively modest predictive value. The lentiform nucleus was the region with the highest AUC (0.78). When GMDS-R were considered, DWI S scores were good to excellent predictors for some GMDS-R subscales. The predictive value of ADC measurements was both region- and subscale-specific. In particular, ADC measurements in some regions (basal ganglia, white matter or rolandic cortex) were excellent predictors for specific GMDS-R with AUCs up to 0.93. DWI S scores showed the highest prognostic value for the neurological outcome at 2 years of age. Regional ADC measurements in specific subregions proved to be highly prognostic for specific neurodevelopmental outcomes.
Andersson, Jesper L.R.; Sotiropoulos, Stamatios N.
2015-01-01
Diffusion MRI offers great potential in studying the human brain microstructure and connectivity. However, diffusion images are marred by technical problems, such as image distortions and spurious signal loss. Correcting for these problems is non-trivial and relies on having a mechanism that predicts what to expect. In this paper we describe a novel way to represent and make predictions about diffusion MRI data. It is based on a Gaussian process on one or several spheres similar to the Geostatistical method of “Kriging”. We present a choice of covariance function that allows us to accurately predict the signal even from voxels with complex fibre patterns. For multi-shell data (multiple non-zero b-values) the covariance function extends across the shells which means that data from one shell is used when making predictions for another shell. PMID:26236030
Cottereau, Anne-Ségolène; Mulé, Sébastien; Lin, Chieh; Belhadj, Karim; Vignaud, Alexandre; Copie-Bergman, Christiane; Boyez, Alice; Zerbib, Pierre; Tacher, Vania; Scherman, Elodie; Haioun, Corinne; Luciani, Alain; Itti, Emmanuel; Rahmouni, Alain
2018-02-01
Purpose To analyze the frequency and distribution of low-signal-intensity regions (LSIRs) in lymphoma lesions and to compare these to fluorodeoxyglucose (FDG) uptake and biologic markers of inflammation. Materials and Methods The authors analyzed 61 untreated patients with a bulky lymphoma (at least one tumor mass ≥7 cm in diameter). When a LSIR within tumor lesions was detected on diffusion-weighted images obtained with a b value of 50 sec/mm 2 , a T2-weighted gradient-echo (GRE) sequence was performed and calcifications were searched for with computed tomography (CT). In two patients, Perls staining was performed on tissue samples from the LSIR. LSIRs were compared with biologic inflammatory parameters and baseline FDG positon emission tomography (PET)/CT parameters (maximum standardized uptake value [SUV max ], total metabolic tumor volume [TMTV]). Results LSIRs were detected in 22 patients and corresponded to signal void on GRE images; one LSIR was due to calcifications, and three LSIRS were due to a recent biopsy. In 18 patients, LSIRs appeared to be related to focal iron deposits; this was proven with Perls staining in two patients. The LSIRs presumed to be due to iron deposits were found mostly in patients with aggressive lymphoma (nine of 26 patients with Hodgkin lymphoma and eight of 20 patients with diffuse large B-cell lymphoma vs one of 15 patients with follicular lymphoma; P = .047) and with advanced stage disease (15 of 18 patients). LSIRS were observed in spleen (n = 14), liver (n = 3), and nodal (n = 8) lesions and corresponded to foci FDG uptake, with mean SUV max of 9.8, 6.7, and 16.2, respectively. These patients had significantly higher serum levels of C-reactive protein, α 1 -globulin, and α 2 -globulin and more frequently had microcytic anemia than those without such deposits (P = .0072, P = .003, P = .0068, and P < .0001, respectively). They also had a significantly higher TMTV (P = .0055) and higher levels of spleen involvement (P < .0001). Conclusion LSIRs due to focal iron deposits are detected in lymphoma lesions and are associated with a more pronounced biologic inflammatory syndrome. © RSNA, 2017 Online supplemental material is available for this article.
Belteki, Gusztav; Lin, Benjamin; Morley, Colin J
2017-10-01
Carbon-dioxide elimination during high-frequency oscillatory ventilation (HFOV) is thought to be proportional to the carbon dioxide diffusion coefficient (DCO 2 ) which is calculated as frequency x (tidal volume) 2 . DCO 2 can be used to as an indicator of CO 2 elimination but values obtained in different patients cannot be directly compared. To analyze the relationship between DCO 2 , the weight-corrected DCO 2 (DCO 2 corr) and blood gas PCO 2 values obtained from infants receiving HFOV. DCO 2 data were obtained from 14 infants at 1/s sampling rate and the mean DCO 2 was determined over 10 min periods preceding the time of the blood gas. DCO 2 corr was calculated by dividing the DCO 2 by the square of the body weight in kg. Weight-correction significantly reduced the inter-individual variability of DCO 2 . When data from all the babies were combined, standard DCO 2 showed no correlation with PCO 2 but DCO 2 corr showed a weak but statistically significant inverse correlation. The correlation was better when the endotracheal leak was <10%. There was significant inverse but weaker correlation between the HFOV tidal volume (VThf) and the PCO 2 . In any baby, DCO 2 corr >50 mL 2 /sec/kg 2 or VThf > 2.5 mL/kg was rarely needed to avoid hypercapnia. Weight-correction of DCO 2 values improved its comparability between patients. Weight-corrected DCO 2 correlated better with PCO 2 than uncorrected DCO 2 but the correlation was weak. © 2017 Wiley Periodicals, Inc.
Ultra high temperature ceramics for hypersonic vehicle applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tandon, Rajan; Dumm, Hans Peter; Corral, Erica L.
2006-01-01
HfB{sub 2} and ZrB{sub 2} are of interest for thermal protection materials because of favorable thermal stability, mechanical properties, and oxidation resistance. We have made dense diboride ceramics with 2 to 20 % SiC by hot pressing at 2000 C and 5000 psi. High-resolution transmission electron microscopy (TEM) shows very thin grain boundary phases that suggest liquid phase sintering. Fracture toughness measurements give RT values of 4 to 6 MPam{sup 1/2}. Four-pt flexure strengths measured in air up to 1450 C were as high as 450-500 MPa. Thermal diffusivities were measured to 2000 C for ZrB{sub 2} and HfB{sub 2}more » ceramics with SiC contents from 2 to 20%. Thermal conductivities were calculated from thermal diffusivities and measured heat capacities. Thermal diffusivities were modeled using different two-phase composite models. These materials exhibit excellent high temperature properties and are attractive for further development for thermal protection systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vandecaveye, Vincent, E-mail: Vincent.Vandecaveye@uzleuven.be; Dirix, Piet; De Keyzer, Frederik
2012-03-01
Purpose: To evaluate diffusion-weighted imaging (DWI) for assessment of treatment response in head and neck squamous cell carcinoma (HNSCC) three weeks after the end of chemoradiotherapy (CRT). Methods and Materials: Twenty-nine patients with HNSCC underwent magnetic resonance imaging (MRI) prior to and 3 weeks after CRT, including T{sub 2}-weighted and pre- and postcontrast T{sub 1}-weighted sequences and an echo-planar DWI sequence with six b values (0 to 1,000 s/mm{sup 2}), from which the apparent diffusion coefficient (ADC) was calculated. ADC changes 3 weeks posttreatment compared to baseline ( Increment ADC) between responding and nonresponding primary lesions and adenopathies were correlatedmore » with 2 years locoregional control and compared with a Mann-Whitney test. In a blinded manner, the Increment ADC was compared to conventional MRI 3 weeks post-CRT and the routinely implemented CT, on average 3 months post-CRT, which used size-related and morphological criteria. Positive and negative predictive values (PPV and NPV, respectively) were compared between the Increment ADC and anatomical imaging. Results: The Increment ADC of lesions with later tumor recurrence was significantly lower than lesions with complete remission for both primary lesions (-2.3% {+-} 0.3% vs. 80% {+-} 41%; p < 0.0001) and adenopathies (19.9% {+-} 32% vs. 63% {+-} 36%; p = 0.003). The Increment ADC showed a PPV of 89% and an NPV of 100% for primary lesions and a PPV of 70% and an NPV of 96% for adenopathies per neck side. DWI improved PPV and NPV compared to anatomical imaging. Conclusion: DWI with the Increment ADC 3 weeks after concluding CRT for HNSCC allows for early assessment of treatment response.« less
Zhan, Yuefu; Liang, Xianwen; Han, Xiangjun; Chen, Jianqiang; Zhang, Shufang; Tan, Shun; Li, Qun; Wang, Xiong; Liu, Fan
2017-02-28
To explore the correlation between the apparent diffusion coefficient (ADC) and mRNA expression of tissue inhibitor of metalloproteinase-1 (TIMP-1) in different stages of liver fibrosis in rats. Methods: A model of liver fibrosis in rats was established by intraperitoneal injection of high-fat diet combined with porcine serum. After drug administration for 4 weeks, 48 rats served as a model group and 12 rats served as a control group, then they underwent diffusion weighted imaging (DWI) scanning. The value of ADC was calculated at b value=800 s/mm2. The rats were sacrificed and carried out pathologic examination after DWI scanning immediately. The mRNA expression of TIMP-1 was detected by real time-polymerase chain reaction (RT-PCR). The rats of hepatic fibrosis were also divided into a S0 group (n=4), a S1 group (n=11), a S2 group (n=12), a S3 group (n=10), and a S4 group (n=9) according to their pathological stage. The value of ADC and the expression of TIMP-1 mRNA among the different stage groups of liver fibrosis were compared, and the correlation between ADC and the TIMP-1 mRNA were analyzed. Results: The ADC value and the TIMP-1 mRNA expression were significantly different between the control group and the liver fibrosis group (F=46.54 and 53.87, P<0.05). There were significant differences in the value of ADC between every two groups (all P<0.05), except the control group vs the S1 group, the S1 group vs the S2 group, and the S2 group vs the S3 group (all P>0.05). For the comparison of TIMP-1 mRNA, there was no significant difference between the S1 group and the S2 group, the S3 group and the S4 group (both P>0.05). There were significant differences among the rest of the groups (all P<0.05). Rank correlation analysis showed that there was a negative correlation between the ADC value and the TIMP-1 mRNA expression (r=-0.76, P<0.01). Conclusion: When the value of ADC decreases in the progress of rats' liver fibrosis, the mRNA expression of TIMP-1 increases gradually, and there is a negative correlation between them.
Lin, Yu-Chun; Lin, Gigin; Hong, Ji-Hong; Lin, Yi-Ping; Chen, Fang-Hsin; Ng, Shu-Hang; Wang, Chun-Chieh
2017-08-01
To investigate the biological meaning of apparent diffusion coefficient (ADC) values in tumors following radiotherapy. Five mice bearing TRAMP-C1 tumor were half-irradiated with a dose of 15 Gy. Diffusion-weighted images, using multiple b-values from 0 to 3000 s/mm 2 , were acquired at 7T on day 6. ADC values calculated by a two-point estimate and monoexponential fitting of signal decay were compared between the irradiated and nonirradiated regions of the tumor. Pixelwise ADC maps were correlated with histological metrics including nuclear counts, nuclear sizes, nuclear spaces, cytoplasmic spaces, and extracellular spaces. As compared with the nonirradiated region, the irradiated region exhibited significant increases in ADC, extracellular space, and nuclear size, and a significant decrease in nuclear counts (P < 0.001 for all). Optimal ADC to differentiate the irradiated from nonirradiated regions was achieved at a b-value of 800 s/mm 2 by the two-point method and monoexponential curve fitting. ADC positively correlated with extracellular spaces (r = 0.74) and nuclear sizes (r = 0.72), and negatively correlated with nuclear counts (r = -0.82, P < 0.001 for all). As a radiomic biomarker, ADC maps correlating with histological metrics pixelwise could be a means of evaluating tumor heterogeneity and responses to radiotherapy. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:483-489. © 2017 International Society for Magnetic Resonance in Medicine.
Mulkern, Robert V; Vajapeyam, Sridhar; Haker, Steven J; Maier, Stephan E
2005-05-01
Magnetization transfer (MT) properties of the fast and slow diffusion components recently observed in the human brain were assessed experimentally. One set of experiments, performed at 1.5 T in healthy volunteers, was designed to determine whether the amplitudes of fast and slow diffusion components, differentiated on the basis of biexponential fits to signal decays over a wide range of b-factors, demonstrated a different or similar magnetization transfer ratio (MTR). Another set of experiments, performed at 3 T in healthy volunteers, was designed to determine whether MTRs differed when measured from high signal-to-noise images acquired with b-factor weightings of 350 vs 3500 s/mm2. The 3 T studies included measurements of MTR as a function of off-resonance frequency for the MT pulse at both low and high b-factors. The primary conclusion drawn from all the studies is that there appears to be no significant difference between the magnetization transfer properties of the fast and slow tissue water diffusion components. The conclusions do not lend support to a direct interpretation of the 'components' of the biexponential diffusion decay in terms of the 'compartments' associated with intra- and extracellular water. Copyright 2004 John Wiley & Sons, Ltd.
Hausmann, Daniel; Liu, Jing; Budjan, Johannes; Reichert, Miriam; Ong, Melissa; Meyer, Mathias; Smakic, Arman; Grimm, Robert; Strecker, Ralph; Schoenberg, Stefan O; Wang, Xiaoying; Attenberger, Ulrike I
2018-02-01
The purpose of this IRB-approved, retrospective study was to compare image quality between 2D and high-resolution 3D, T2-weighted (T2WI) magnetic resonance imaging (MRI) sequences and to investigate the additional value of ultra-high b-value diffusion-weighted imaging (DWI; b=2,000 mm/s 2 ) for both rectal cancer staging and evaluating treatment response. From 12 February to 24 August 2016, 26 consecutive patients (22 males, four females; mean age: 61.9±14.0 years) with histologically-proven rectal cancer. In total 31 examinations [12 prior to and 19 after chemoradiation (CRT)] were included. The patients underwent pelvic MRI on a 3.0-T scanner (Magnetom Skyra, Erlangen, Germany). Three radiologists (3, 4, and 5 years of experience in MRI, respectively) independently assessed all images and rated the image quality of DWI (b=800 mm/s 2 ), apparent diffusion coefficient map, DWI (b=2,000 mm/s 2 ), 3D sagittal T2WI, 3D axial T2WI, 2D sagittal T2WI, and 2D axial T2WI of each patient, respectively. In addition, signal intensity ratios (SIR) were calculated between rectal cancer and obturator internus muscle (background) in all patients after CRT on DWI (b=2,000 mm/s 2 ) and correlated with histopathological regression grade (RG). Tumor delineation was significantly better by 2D T2WI than 3D T2WI both before and after CRT (before CRT: Z=-3.2, p=0.02; after CRT: Z=-4.408, p<0.001; all: Z=-5.192; p<0.001) and was the preferred method, although image quality ratings were not significantly different (3D sagittal: 4.00±0.48; 2D sagittal: 4.03±0.34, p=0.713; 3D axial: 3.85±0.61, 2D axial: 3.78±0.64, p=0.537). Independent t-test showed significantly higher SIR between those with RG 1 or 2 (moderate response: mean score=2.02) and those with RG 3+4 (good response: mean score=0.8) (t=3.044, p=0.011). In those with RG 4 (complete response), SIR of b2000 was 0.946 compared to a 1.41 average of the whole cohort. In two patients, tumor was invisible on b2000 following CRT (RG 3 and 4, respectively). Interobserver agreement was mostly good (κ≥0.6) regarding image quality assessment, except for poor agreement (κ=0.4) in DWI (b2000) between the two less-experienced readers. In conclusion, 3D T2WI might be useful for evaluating response to neoadjuvant therapy in a comprehensive, cost-effective protocol, where 2D imaging seems to be preferable. In addition, DWI (b2000) may be beneficial in assessing both the primary and the residual tumor after CRT in rectal cancer and SIR may be helpful in assessing response to CRT. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Razavilar, Negin; Choi, Phillip
2014-07-08
Isobaric-isothermal molecular dynamics simulation was used to study the diffusion of a hydrophobic drug Cucurbitacin B (CuB) in pseudomicelle environments consisting of poly(ethylene oxide-b-caprolactone) (PEO-b-PCL) swollen by various amounts of water. Two PEO-b-PCL configurations, linear and branched, with the same total molecular weight were used. For the branched configuration, the block copolymer contained one linear block of PEO with the same molecular weight as that of the PEO block used in the linear configuration but with one end connecting to three PCL blocks with the same chain length, hereafter denoted PEO-b-3PCL. Regardless of the configuration, the simulation results showed that the diffusivity of CuB was insensitive to the water concentration up to ∼8 wt % while that of water decreased with an increasing water concentration. The diffusivity of CuB (10(-8) cm(2)/s) was 3 orders of magnitude lower than that of water (10(-5) cm(2)/s). This is attributed to the fact that CuB relied on the wiggling motion of the block copolymers to diffuse while water molecules diffused via a hopping mechanism. The rates at which CuB and water diffused into PEO-b-PCL were twice those in PEO-b-3PCL because the chain mobility and the degree of swelling are higher and there are fewer intermolecular hydrogen bonds in the case of PEO-b-PCL. The velocity autocorrelation functions of CuB show that the free volume holes formed by PEO-b-3PCL are more rigid than those formed by PEO-b-PCL, making CuB exhibit higher-frequency collision motion in PEO-b-3PCL than in PEO-b-PCL, and the difference in frequency is insensitive to water concentration.
Khemani, S; Lingam, R K; Kalan, A; Singh, A
2011-08-01
To evaluate the diagnostic performance of half-Fourier-acquisition single-shot turbo-spin-echo (HASTE) diffusion-weighted magnetic resonance imaging in the detection, localisation and prediction of extent of cholesteatoma following canal wall up mastoid surgery. Prospective blinded observational study. University affiliated teaching hospital. Forty-eight patients undergoing second-look surgery after previous canal wall up mastoid surgery for primary acquired cholesteatoma. All patients underwent non-echo planar HASTE diffusion-weighted imaging prior to being offered 'second-look' surgery. Radiological findings were correlated with second-look intra-operative findings in 38 cases with regard to presence, location and maximum dimensions of cholesteatoma. Half-Fourier-acquisition single-shot turbo-spin-echo diffusion-weighted imaging accurately predicted the presence of cholesteatoma in 23 of 28 cases, and it correctly excluded in nine of 10 cases. Five false negatives were caused by keratin pearls of <2 mm and in one case 5 mm. Overall sensitivity and specificity for detection of cholesteatoma were 82% (95% confidence interval [CI] 62-94%) and 90% (CI 55-100%), respectively. Positive predictive value and negative predictive value were 96% (CI 79-100%) and 64% (CI 35-87%), respectively. Overall accuracy for detection of cholesteatoma was 84% (CI 69-94%). Half-Fourier-acquisition single-shot turbo-spin-echo diffusion-weighted imaging has good performance in localising cholesteatoma to a number of anatomical sub-sites within the middle ear and mastoid (sensitivity ranging from 75% to 88% and specificity ranging from 94% to 100%). There was no statistically significant difference in the size of cholesteatoma detected radiologically and that found during surgery (paired t-test, P = 0.16). However, analysis of size agreement suggests possible radiological underestimation of size when using HASTE diffusion-weighted imaging (mean difference -0.6 mm, CI -5.3 to 4.6 mm). Half-Fourier-acquisition single-shot turbo-spin-echo diffusion-weighted imaging performs reasonably well in predicting the presence and location of postoperative cholesteatoma but may miss small foci of disease and may underestimate the true size of cholesteatoma. © 2011 Blackwell Publishing Ltd.
Chang, Hing-Chiu; Bilgin, Ali; Bernstein, Adam; Trouard, Theodore P.
2018-01-01
Over the past several years, significant efforts have been made to improve the spatial resolution of diffusion-weighted imaging (DWI), aiming at better detecting subtle lesions and more reliably resolving white-matter fiber tracts. A major concern with high-resolution DWI is the limited signal-to-noise ratio (SNR), which may significantly offset the advantages of high spatial resolution. Although the SNR of DWI data can be improved by denoising in post-processing, existing denoising procedures may potentially reduce the anatomic resolvability of high-resolution imaging data. Additionally, non-Gaussian noise induced signal bias in low-SNR DWI data may not always be corrected with existing denoising approaches. Here we report an improved denoising procedure, termed diffusion-matched principal component analysis (DM-PCA), which comprises 1) identifying a group of (not necessarily neighboring) voxels that demonstrate very similar magnitude signal variation patterns along the diffusion dimension, 2) correcting low-frequency phase variations in complex-valued DWI data, 3) performing PCA along the diffusion dimension for real- and imaginary-components (in two separate channels) of phase-corrected DWI voxels with matched diffusion properties, 4) suppressing the noisy PCA components in real- and imaginary-components, separately, of phase-corrected DWI data, and 5) combining real- and imaginary-components of denoised DWI data. Our data show that the new two-channel (i.e., for real- and imaginary-components) DM-PCA denoising procedure performs reliably without noticeably compromising anatomic resolvability. Non-Gaussian noise induced signal bias could also be reduced with the new denoising method. The DM-PCA based denoising procedure should prove highly valuable for high-resolution DWI studies in research and clinical uses. PMID:29694400
[Optimization of diagnosis indicator selection and inspection plan by 3.0T MRI in breast cancer].
Jiang, Zhongbiao; Wang, Yunhua; He, Zhong; Zhang, Lejun; Zheng, Kai
2013-08-01
To optimize 3.0T MRI diagnosis indicator in breast cancer and to select the best MRI scan program. Totally 45 patients with breast cancers were collected, and another 35 patients with benign breast tumor served as the control group. All patients underwent 3.0T MRI, including T1- weighted imaging (T1WI), fat suppression of the T2-weighted imaging (T2WI), diffusion weighted imaging (DWI), 1H magnetic resonance spectroscopy (1H-MRS) and dynamic contrast enhanced (DCE) sequence. With operation pathology results as the gold standard in the diagnosis of breast diseases, the pathological results of benign and malignant served as dependent variables, and the diagnostic indicators of MRI were taken as independent variables. We put all the indicators of MRI examination under Logistic regression analysis, established the Logistic model, and optimized the diagnosis indicators of MRI examination to further improve MRI scan of breast cancer. By Logistic regression analysis, some indicators were selected in the equation, including the edge feature of the tumor, the time-signal intensity curve (TIC) type and the apparent diffusion coefficient (ADC) value when b=500 s/mm2. The regression equation was Logit (P)=-21.936+20.478X6+3.267X7+ 21.488X3. Valuable indicators in the diagnosis of breast cancer are the edge feature of the tumor, the TIC type and the ADC value when b=500 s/mm2. Combining conventional MRI scan, DWI and dynamic enhanced MRI is a better examination program, while MRS is the complementary program when diagnosis is difficult.
Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging
Raval, Shailesh B.; Britton, Cynthia A.; Zhao, Tiejun; Krishnamurthy, Narayanan; Santini, Tales; Gorantla, Vijay S.; Ibrahim, Tamer S.
2017-01-01
Objective The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity]. Materials and method A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization]. Results High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]—images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The proper digital palmar arteries and superficial palmar arch could also be clearly visualized using TOF nCE 7T MRI. Conclusion Ultra-high resolution neurovascular imaging in upper extremities is possible at 7T without use of renal toxic intravenous contrast. 7T MRI can provide superior peripheral nerve [based on fiber anisotropy and diffusion coefficient parameters derived from diffusion tensor/spectrum imaging] and vascular [nCE MRA and vessel segmentation] imaging. PMID:28662061
Yan, Ren; Haopeng, Pang; Xiaoyuan, Feng; Jinsong, Wu; Jiawen, Zhang; Chengjun, Yao; Tianming, Qiu; Ji, Xiong; Mao, Sheng; Yueyue, Ding; Yong, Zhang; Jianfeng, Luo; Zhenwei, Yao
2016-02-01
This study was conducted to compare the association of Gaussian and non-Gaussian magnetic resonance imaging (MRI)-derived parameters with histologic grade and MIB-1 (Ki-67 labeling) index (MI) in brain glioma. Sixty-five patients with pathologically confirmed glioma, who underwent diffusion-weighted MRI with 2 b values (0, 1000 s/mm(2)) and 22 b values (≤5000 s/mm(2)), respectively, were divided into three groups of grade II (n = 35), grade III (n = 8), and grade IV (n = 22). Comparisons by two groups were made for apparent diffusion coefficient (ADC), slow diffusion coefficient (Dslow), distributed diffusion coefficient (DDC), and heterogeneity index α. Analyses of receiver operating characteristic (ROC) curve were performed to maximize the area under the curve (AUC) for differentiating grade III + IV (high-grade glioma, HGG) from grade II (low-grade glioma, LGG) and grade IV (glioblastoma multiforme, GBM) from grade II + III (other grade glioma, OGG). Correlations with MI were analyzed for the MRI parameters. On tumor regions, the values of ADC, Dslow, DDC, and α were significantly higher in grade II [(1.37 ± 0.29, 0.70 ± 0.11, 1.39 ± 0.34) (×10(-3) mm(2)/s) and 0.88 ± 0.05, respectively] than in grade III [(0.99 ± 0.13, 0.55 ± 0.07, 1.04 ± 0.20) (×10(-3) mm(2)/s) and 0.80 ± 0.03, respectively] and grade IV [(1.03 ± 0.14, 0.50 ± 0.05, 1.02 ± 0.16) (×10(-3) mm(2)/s) and 0.76 ± 0.04, respectively] (all P < 0.001). The parameter α showed the highest AUCs of 0.950 and 0.922 in discriminating HGG from LGG and GBM from OGG, respectively. Significant correlations with histologic grade and MI were observed for the MRI parameters. The non-Gaussian MRI-derived parameters α and Dslow are superior to ADC in glioma grading, which are comparable with ADC as reliable biomarkers in noninvasively predicting the proliferation level of glioma malignancy.
Newitt, David C; Malyarenko, Dariya; Chenevert, Thomas L; Quarles, C Chad; Bell, Laura; Fedorov, Andriy; Fennessy, Fiona; Jacobs, Michael A; Solaiyappan, Meiyappan; Hectors, Stefanie; Taouli, Bachir; Muzi, Mark; Kinahan, Paul E; Schmainda, Kathleen M; Prah, Melissa A; Taber, Erin N; Kroenke, Christopher; Huang, Wei; Arlinghaus, Lori R; Yankeelov, Thomas E; Cao, Yue; Aryal, Madhava; Yen, Yi-Fen; Kalpathy-Cramer, Jayashree; Shukla-Dave, Amita; Fung, Maggie; Liang, Jiachao; Boss, Michael; Hylton, Nola
2018-01-01
Diffusion weighted MRI has become ubiquitous in many areas of medicine, including cancer diagnosis and treatment response monitoring. Reproducibility of diffusion metrics is essential for their acceptance as quantitative biomarkers in these areas. We examined the variability in the apparent diffusion coefficient (ADC) obtained from both postprocessing software implementations utilized by the NCI Quantitative Imaging Network and online scan time-generated ADC maps. Phantom and in vivo breast studies were evaluated for two ([Formula: see text]) and four ([Formula: see text]) [Formula: see text]-value diffusion metrics. Concordance of the majority of implementations was excellent for both phantom ADC measures and in vivo [Formula: see text], with relative biases [Formula: see text] ([Formula: see text]) and [Formula: see text] (phantom [Formula: see text]) but with higher deviations in ADC at the lowest phantom ADC values. In vivo [Formula: see text] concordance was good, with typical biases of [Formula: see text] to 3% but higher for online maps. Multiple b -value ADC implementations were separated into two groups determined by the fitting algorithm. Intergroup mean ADC differences ranged from negligible for phantom data to 2.8% for [Formula: see text] in vivo data. Some higher deviations were found for individual implementations and online parametric maps. Despite generally good concordance, implementation biases in ADC measures are sometimes significant and may be large enough to be of concern in multisite studies.
Wang, Tingting; Wu, Xiangru; Cui, Yanfen; Chu, Caiting; Ren, Gang; Li, Wenhua
2014-11-29
Benign and malignant bone tumors can present similar imaging features. This study aims to evaluate the significance of apparent diffusion coefficients (ADC) in differentiating between benign and malignant bone tumors. A total of 187 patients with 198 bone masses underwent diffusion-weighted (DW) magnetic resonance (MR) imaging. The ADC values in the solid components of the bone masses were assessed. Statistical differences between the mean ADC values in the different tumor types were determined by Student's t-test. Histological analysis showed that 84/198 (42.4%) of the bone masses were benign and 114/198 (57.6%) were malignant. There was a significant difference between the mean ADC values in the benign and malignant bone lesions (P<0.05). However, no significant difference was found in the mean ADC value between non-ossifying fibromas, osteofibrous dysplasia, and malignant bone tumors. When an ADC cutoff value≥1.10×10(-3) mm2/s was applied, malignant bone lesions were excluded with a sensitivity of 89.7%, a specificity of 84.5%, a positive predictive value of 82.6%, and a negative predictive value of 95.3%. The combination of DW imaging with ADC quantification and T2-weighted signal characteristics of the solid components in lesions can facilitate differentiation between benign and malignant bone tumors.
Wu, X; Reinikainen, P; Vanhanen, A; Kapanen, M; Vierikko, T; Ryymin, P; Hyödynmaa, S; Kellokumpu-Lehtinen, P-L
2017-01-01
To investigate whether diffusion-weighted imaging (DWI) apparent diffusion coefficient (ADC) correlates with prostate cancer aggressiveness and further to compare the diagnostic performance of ADC and normalized ADC (nADC: normalized to non-tumor tissue). Thirty pre-treatment patients (mean age, 69years; range: 59-78years) with prostate cancer underwent magnetic resonance imaging (MRI) examination, including DWI with three b values: 50, 400, and 800s/mm 2 . Both ADC and nADC were correlated with the Gleason score obtained through transrectal ultrasound-guided biopsy. The tumor minimum ADC (ADC min : the lowest ADC value within tumor) had an inverse correlation with the Gleason score (r=-0.43, P<0.05), and it was lower in patients with Gleason score 3+4 than in those with Gleason score 3+3 (0.54±0.11×10 3 mm 2 /s vs. 0.64±0.12×10 -3 mm 2 /s, P<0.05). Both the nADC min and nADC mean correlated with the Gleason score (r=-0.52 and r=-0.55, P<0.01; respectively), and they were lower in patients with Gleason score 3+4 than those with Gleason score 3+3 (P<0.01; respectively). Receiver operating characteristic (ROC) analysis showed that the area under the ROC curve was 0.765, 0.818, or 0.833 for the ADC min , nADC min , or nADC mean ; respectively, in differentiating between Gleason score 3+4 and 3+3 tumors. Tumor ADC min , nADC min , and nADC mean are useful markers to predict the aggressiveness of prostate cancer. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Suo, Shi-Teng; Chen, Xiao-Xi; Fan, Yu; Wu, Lian-Ming; Yao, Qiu-Ying; Cao, Meng-Qiu; Liu, Qiang; Xu, Jian-Rong
2014-08-01
To investigate the potential value of histogram analysis of apparent diffusion coefficient (ADC) obtained at standard (700 s/mm(2)) and high (1500 s/mm(2)) b values on a 3.0-T scanner in the differentiation of bladder cancer from benign lesions and in assessing bladder tumors of different pathologic T stages and to evaluate the diagnostic performance of ADC-based histogram parameters. In all, 52 patients with bladder lesions, including benign lesions (n = 7) and malignant tumors (n = 45; T1 stage or less, 23; T2 stage, 7; T3 stage, 8; and T4 stage, 7), were retrospectively evaluated. Magnetic resonance examination at 3.0 T and diffusion-weighted imaging were performed. ADC maps were obtained at two b values (b = 700 and 1500 s/mm(2); ie, ADC-700 and ADC-1500). Parameters of histogram analysis included mean, kurtosis, skewness, and entropy. The correlations between these parameters and pathologic results were revealed. Receiver operating characteristic (ROC) curves were generated to determine the diagnostic value of histogram parameters. Significant differences were found in mean ADC-700, mean ADC-1500, skewness ADC-1500, and kurtosis ADC-1500 between bladder cancer and benign lesions (P = .002-.032). There were also significant differences in mean ADC-700, mean ADC-1500, and kurtosis ADC-1500 among bladder tumors of different pathologic T stages (P = .000-.046). No significant differences were observed in other parameters. Mean ADC-1500 and kurtosis ADC-1500 were significantly correlated with T stage, respectively (ρ = -0.614, P < .001; ρ = 0.374, P = .011). ROC analysis showed that the combination of mean ADC-1500 and kurtosis ADC-1500 has the maximal area under the ROC curve (AUC, 0.894; P < .001) in the differentiation of benign lesions and malignant tumors, with a sensitivity of 77.78% and specificity of 100%. AUCs for differentiating low- and high-stage tumors were 0.840 for mean ADC-1500 (P < .001) and 0.696 for kurtosis ADC-1500 (P = .015). Histogram analysis of ADC-1500 at 3.0 T can be useful in evaluation of bladder lesions. A combination of mean ADC-1500 and kurtosis ADC-1500 may be more beneficial in the differentiation of benign and malignant lesions. Mean ADC-1500 was the most promising parameter for differentiating low- from high-stage bladder cancer. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Can diffusion-weighted imaging serve as a biomarker of fibrosis in pancreatic adenocarcinoma?
Hecht, Elizabeth M; Liu, Michael Z; Prince, Martin R; Jambawalikar, Sachin; Remotti, Helen E; Weisberg, Stuart W; Garmon, Donald; Lopez-Pintado, Sara; Woo, Yanghee; Kluger, Michael D; Chabot, John A
2017-08-01
To assess the relationship between diffusion-weighted imaging (DWI) and intravoxel incoherent motion (IVIM)-derived quantitative parameters (apparent diffusion coefficient [ADC], perfusion fraction [f], D slow , diffusion coefficient [D], and D fast , pseudodiffusion coefficient [D*]) and histopathology in pancreatic adenocarcinoma (PAC). Subjects with suspected surgically resectable PAC were prospectively enrolled in this Health Insurance Portability and Accountability Act (HIPAA)-compliant, Institutional Review Board-approved study. Imaging was performed at 1.5T with a respiratory-triggered echo planar DWI sequence using 10 b values. Two readers drew regions of interest (ROIs) over the tumor and adjacent nontumoral tissue. Monoexponential and biexponential fits were used to derive ADC 2b , ADC all , f, D, and D*, which were compared to quantitative histopathology of fibrosis, mean vascular density, and cellularity. Two biexponential IVIM models were investigated and compared: 1) nonlinear least-square fitting based on the Levenberg-Marquardt algorithm, and 2) linear fit using a fixed D* (20 mm 2 /s). Statistical analysis included Student's t-test, Pearson correlation (P < 0.05 was considered significant), intraclass correlation, and coefficients of variance. Twenty subjects with PAC were included in the final cohort. Negative correlation between D and fibrosis (Reader 2: r = -0.57 P = 0.01; pooled P = -0.46, P = 0.04) was observed with a trend toward positive correlation between f and fibrosis (r = 0.44, P = 0.05). ADC 2b was significantly lower in PAC with dense fibrosis than with loose fibrosis ADC 2b (P = 0.03). Inter- and intrareader agreement was excellent for ADC, D, and f. In PAC, D negatively correlates with fibrosis, with a trend toward positive correlation with f suggesting both perfusion and diffusion effects contribute to stromal desmoplasia. ADC 2b is significantly lower in tumors with dense fibrosis and may serve as a biomarker of fibrosis architecture. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:393-402. © 2017 International Society for Magnetic Resonance in Medicine.
Shang, Liu-Tong; Yang, Jia-Fei; Lu, Jing; Wang, Ting-Ting; Zhou, Ying; Xing, Xin-Bo; Wang, Xin-Kun; Yang, Shu-Hui; Hu, Ming-Yan
2017-10-20
To study the correlation of apparent diffusion coefficient (ADC) measured by diffusion-weighted magnetic resonance imaging (MRI) with the molecular subtypes and biological prognostic factors of invasive breast cancer masses. Breast MRI data (including dynamic enhanced and diffusion-weighted imaging) were collected from 64 patients with pathologically confirmed invasive breast cancer masses (a total of 69 lesions). The mean ADC values of the lesions were calculated and their correlations were analyzed with the 5 molecular subtypes of invasive breast cancer and the biological prognostic factors including estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor 2 (HER2), and Ki-67 index. The ADC values did not differ significantly among the 5 molecular subtypes of invasive breast cancer masses (P>0.05) or among lesions with different ER, PR, or HER2 status (P>0.05). The mean ADC values were significantly higher in Ki-67-positive lesions than in the negative lesions (P=0.023 and negatively correlated with the expressions of Ki-67 (r=-0.249). ADC value can not be used to identify the molecular subtypes of invasive breast cancer masses or to evaluate the biological prognosis of the lesions, but its correlation with Ki-67 expression may help in prognostic evaluation and guiding clinical therapy of the tumors.
Resorlu, Hatice; Resorlu, Mustafa; Gokmen, Ferhat; Akbal, Ayla; Adam, Gurhan; Komurcu, Erkam; Goksel, Ferdi; Guven, Mustafa; Aras, Adem Bozkurt; Sariyildirim, Abdullah; Cevizci, Sibel
2015-01-01
[Purpose] The aim this study was to assess the relation between bone mineral density (BMD) and mean platelet volume (MPV) in ankylosing spondylitis (AS) patients, and evaluate the diagnostic role of the diffusion-weighted magnetic resonance imaging (MRI). [Subjects and Methods] Fifty patients diagnosed with AS were divided into two groups on the basis of BMD, a normal group (n=30) and an osteopenic (n=20) group. [Results] Duration of disease in the group with a normal BMD was 10.3±7.0 years, while it was 16.7±12.2 years in the osteopenia group. MPV was high in the osteopenia group, while no significant differences were observed between the groups in terms of apparent diffusion coefficient (ADC) and platelet distribution width (PDW). There was a positive correlation between MPV and duration of disease. Correlations between ADC value and the lumbar T score, femoral neck T score, and duration of disease were insignificant. A negative correlation was observed between BMD and disease duration. [Conclusion] Diffusion-weighted imaging provides valuable results in osteoporosis but is not a suitable technique for evaluating BMD in patients with AS because of the local and systemic inflammatory effects in the musculoskeletal system. The common pathophysiology of atherosclerosis and osteoporosis plays an important role in the negative correlation observed between MPV and BMD in patients with AS. PMID:25995574
Modifications of pancreatic diffusion MRI by tissue characteristics: what are we weighting for?
Nissan, Noam
2017-08-01
Diffusion-weighted imaging holds the potential to improve the diagnosis and biological characterization of pancreatic disease, and in particular pancreatic cancer, which exhibits decreased values of the apparent diffusion coefficient (ADC). Yet, variable and overlapping ADC values have been reported for the healthy and the pathological pancreas, including for cancer and other benign conditions. This controversy reflects the complexity of probing the water-diffusion process in the pancreas, which is dependent upon multiple biological factors within this organ's unique physiological environment. In recent years, extensive studies have investigated the correlation between tissue properties including cellularity, vascularity, fibrosis, secretion and microstructure and pancreatic diffusivity. Understanding how the various physiological and pathological features and the underlying functional processes affect the diffusion measurement may serve to optimize the method for improved diagnostic gain. Therefore, the aim of the present review article is to elucidate the relationship between pancreatic tissue characteristics and diffusion MRI measurement. Copyright © 2017 John Wiley & Sons, Ltd.
MGH-USC Human Connectome Project Datasets with Ultra-High b-Value Diffusion MRI
Fan, Qiuyun; Witzel, Thomas; Nummenmaa, Aapo; Van Dijk, Koene R.A.; Van Horn, John D.; Drews, Michelle K.; Somerville, Leah H.; Sheridan, Margaret A.; Santillana, Rosario M.; Snyder, Jenna; Hedden, Trey; Shaw, Emily E.; Hollinshead, Marisa O.; Renvall, Ville; Zanzonico, Roberta; Keil, Boris; Cauley, Stephen; Polimeni, Jonathan R.; Tisdall, Dylan; Buckner, Randy L.; Wedeen, Van J.; Wald, Lawrence L.; Toga, Arthur W.; Rosen, Bruce R.
2015-01-01
The MGH-USC CONNECTOM MRI scanner housed at the Massachusetts General Hospital (MGH) is a major hardware innovation of the Human Connectome Project (HCP). The 3T CONNECTOM scanner is capable of producing magnetic field gradient of up to 300 mT/m strength for in vivo human brain imaging, which greatly shortens the time spent on diffusion encoding, and decreases the signal loss due to T2 decay. To demonstrate the capability of the novel gradient system, data of healthy adult participants were acquired for this MGH-USC Adult Diffusion Dataset (N=35), minimally preprocessed, and shared through the Laboratory of Neuro Imaging Image Data Archive (LONI IDA) and the WU-Minn Connectome Database (ConnecomeDB). Another purpose of sharing the data is to facilitate methodological studies of diffusion MRI (dMRI) analyses utilizing high diffusion contrast, which perhaps is not easily feasible with standard MR gradient system. In addition, acquisition of the MGH-Harvard-USC Lifespan Dataset is currently underway to include 120 healthy participants ranging from 8 to 90 years old, which will also be shared through LONI IDA and ConnectomeDB. Here we describe the efforts of the MGH-USC HCP consortium in acquiring and sharing the ultra-high b-value diffusion MRI data and provide a report on data preprocessing and access. We conclude with a demonstration of the example data, along with results of standard diffusion analyses, including q-ball Orientation Distribution Function (ODF) reconstruction and tractography. PMID:26364861
Intensity ratio to improve black hole assessment in multiple sclerosis.
Adusumilli, Gautam; Trinkaus, Kathryn; Sun, Peng; Lancia, Samantha; Viox, Jeffrey D; Wen, Jie; Naismith, Robert T; Cross, Anne H
2018-01-01
Improved imaging methods are critical to assess neurodegeneration and remyelination in multiple sclerosis. Chronic hypointensities observed on T1-weighted brain MRI, "persistent black holes," reflect severe focal tissue damage. Present measures consist of determining persistent black holes numbers and volumes, but do not quantitate severity of individual lesions. Develop a method to differentiate black and gray holes and estimate the severity of individual multiple sclerosis lesions using standard magnetic resonance imaging. 38 multiple sclerosis patients contributed images. Intensities of lesions on T1-weighted scans were assessed relative to cerebrospinal fluid intensity using commercial software. Magnetization transfer imaging, diffusion tensor imaging and clinical testing were performed to assess associations with T1w intensity-based measures. Intensity-based assessments of T1w hypointensities were reproducible and achieved > 90% concordance with expert rater determinations of "black" and "gray" holes. Intensity ratio values correlated with magnetization transfer ratios (R = 0.473) and diffusion tensor imaging metrics (R values ranging from 0.283 to -0.531) that have been associated with demyelination and axon loss. Intensity ratio values incorporated into T1w hypointensity volumes correlated with clinical measures of cognition. This method of determining the degree of hypointensity within multiple sclerosis lesions can add information to conventional imaging. Copyright © 2017 Elsevier B.V. All rights reserved.
Multi-Objective Memetic Search for Robust Motion and Distortion Correction in Diffusion MRI.
Hering, Jan; Wolf, Ivo; Maier-Hein, Klaus H
2016-10-01
Effective image-based artifact correction is an essential step in the analysis of diffusion MR images. Many current approaches are based on retrospective registration, which becomes challenging in the realm of high b -values and low signal-to-noise ratio, rendering the corresponding correction schemes more and more ineffective. We propose a novel registration scheme based on memetic search optimization that allows for simultaneous exploitation of different signal intensity relationships between the images, leading to more robust registration results. We demonstrate the increased robustness and efficacy of our method on simulated as well as in vivo datasets. In contrast to the state-of-art methods, the median target registration error (TRE) stayed below the voxel size even for high b -values (3000 s ·mm -2 and higher) and low SNR conditions. We also demonstrate the increased precision in diffusion-derived quantities by evaluating Neurite Orientation Dispersion and Density Imaging (NODDI) derived measures on a in vivo dataset with severe motion artifacts. These promising results will potentially inspire further studies on metaheuristic optimization in diffusion MRI artifact correction and image registration in general.
Tax, Chantal M.W.; Haije, Tom Dela; Fuster, Andrea; Westin, Carl-Fredrik; Viergever, Max A.; Florack, Luc; Leemans, Alexander
2017-01-01
The question whether our brain pathways adhere to a geometric grid structure has been a popular topic of debate in the diffusion imaging and neuroscience society. Wedeen et al. (2012a b) proposed that the brain’s white matter is organized like parallel sheets of interwoven pathways. Catani et al. (2012) concluded that this grid pattern is most likely an artifact, resulting from methodological biases that cause the tractography pathways to cross in orthogonal angles. To date, ambiguities in the mathematical conditions for a sheet structure to exist (e.g. its relation to orthogonal angles) combined with the lack of extensive quantitative evidence have prevented wide acceptance of the hypothesis. In this work, we formalize the relevant terminology and recapitulate the condition for a sheet structure to exist. Note that this condition is not related to the presence or absence of orthogonal crossing fibers, and that sheet structure is defined formally as a surface formed by two sets of interwoven pathways intersecting at arbitrary angles within the surface. To quantify the existence of sheet structure, we present a novel framework to compute the sheet probability index (SPI), which reflects the presence of sheet structure in discrete orientation data (e.g. fiber peaks derived from diffusion MRI). With simulation experiments we investigate the effect of spatial resolution, curvature of the fiber pathways, and measurement noise on the ability to detect sheet structure. In real diffusion MRI data experiments we can identify various regions where the data supports sheet structure (high SPI values), but also areas where the data does not support sheet structure (low SPI values) or where no reliable conclusion can be drawn. Several areas with high SPI values were found to be consistent across subjects, across multiple data sets obtained with different scanners, resolutions, and degrees of diffusion weighting, and across various modeling techniques. Under the strong assumption that the diffusion MRI peaks reflect true axons, our results would therefore indicate that pathways do not form sheet structures at every crossing fiber region but instead at well-defined locations in the brain. With this framework, sheet structure location, extent, and orientation could potentially serve as new structural features of brain tissue. The proposed method can be extended to quantify sheet structure in directional data obtained with techniques other than diffusion MRI, which is essential for further validation. PMID:27456538
Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI.
Wilm, Bertram J; Barmet, Christoph; Gross, Simon; Kasper, Lars; Vannesjo, S Johanna; Haeberlin, Max; Dietrich, Benjamin E; Brunner, David O; Schmid, Thomas; Pruessmann, Klaas P
2017-01-01
The purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. Image formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B 0 , and coil sensitivity encoding. The encoding model is determined by B 0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. Using the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. Use of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Xue, L J; Yang, A C; Chen, H; Huang, W X; Guo, J J; Liang, X Y; Chen, Z Q; Zheng, Q L
2017-11-20
Objective: Study of the results and the degree on occupational noise-induced deafness in-to the different high frequency hearing threshold weighted value, in order to provide theoretical basis for the re-vision of diagnostic criteria on occupational noise-induced deafness. Methods: A retrospective study was con-ducted to investigate the cases on the diagnosis of occupational noise-induced deafness in Guangdong province hospital for occupational disease prevention and treatment from January 2016 to January 2017. Based on the re-sults of the 3 hearing test for each test interval greater than 3 days in the hospital, the best threshold of each frequency was obtained, and based on the diagnostic criteria of occupational noise deafness in 2007 edition, Chi square test, t test and variance analysis were used to measure SPSS21.0 data, their differences are tested among the means of speech frequency and the high frequency weighted value into different age group, noise ex-posure group, and diagnostic classification between different dimensions. Results: 1. There were totally 168 cases in accordance with the study plan, male 154 cases, female 14 cases, the average age was 41.18 ±6.07 years old. 2. The diagnosis rate was increased into the weighted value of different high frequency than the mean value of pure speech frequency, the weighted 4 kHz frequency increased by 13.69% (χ(2)=9.880, P =0.002) , 6 kHz increased by 15.47% (χ(2)=9.985, P =0.002) and 4 kHz+6 kHz increased by15.47% (χ(2)=9.985, P =0.002) , the difference was statistically significant. The diagnostic rate of different high threshold had no obvious differ-ence between the genders. 3. The age groups were divided into less than or equal to 40years old group (A group) and 40-50 years old group (group B) , there were higher the diagnostic rate between high frequency weighted 4 kHz (A group χ(2)=3.380, P =0.050; B group χ(2)=4.054, P =0.032) , weighted 6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) , high frequency weighted 4 kHz+6 kHz (A group χ(2)=6.362, P =0.012; B group χ(2)=4.054, P =0.032) than those of speech frequency average value in the same group on oc-cupational noise-induced deafness diagnosis rate, the difference was statistically significant. There was no sig-nificant difference between age groups (χ(2)=2.265, P =0.944) . 4. The better ear's mean value of pure speech fre-quency and the weighted values into different high frequency of working years on each group were compared, working years more than 10 years group was significantly higher than that of average thresholds of each frequen-cy band in 3-5 group ( F =2.271, P =0.001) , 6-10 group ( F =1.563, P =0.046) , the difference was statistically significant. The different high frequency weighted values were higher than those of the mean value of pure speech frequency, and the high frequency weighted 4 kHz+6 kHz had the highest frequency difference, with an average increase of 2.83 dB. 5. The diagnostic rate into weighted different high frequency was higher in the mild, moderate and severe grades than in the pure speech frequency. In the comparison of diagnosis for mild occupational noise-induced deafness, in addition to the weighted 3 kHz high frequency (χ(2)=3.117, P =0.077) had no significant difference, the weighted 4 kHz (χ(2)=10.835, P =0.001) , 6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz (χ(2)=6.315, P =0.012) , 3 kHz+6 kHz (χ(2)=6.315, P =0.012) , 4 kHz+6 kHz (χ(2)=9.985, P =0.002) , 3 kHz+4 kHz+6 kHz (χ(2)=7.667, P =0.002) were significantly higher than the diagnosis rate of the mean value of pure speech frequency. There was no significant difference between the two groups in the moderate and se-vere grades ( P >0.05) . Conclusion: Bring into different high frequency hearing threshold weighted value in-creases the diagnostic rate of occupational noise-induced deafness, the weighted 4 kHz, 6 kHz and 4 kHz+ 6 kHz high frequency value affects the result greatly, and the weighted 4 kHz+6 kHz high frequency hearing threshold value is maximum the effect on occupational noise-induced deafness diagnosis.
Prediction of stream volatilization coefficients
Rathbun, Ronald E.
1990-01-01
Equations are developed for predicting the liquid-film and gas-film reference-substance parameters for quantifying volatilization of organic solutes from streams. Molecular weight and molecular-diffusion coefficients of the solute are used as correlating parameters. Equations for predicting molecular-diffusion coefficients of organic solutes in water and air are developed, with molecular weight and molal volume as parameters. Mean absolute errors of prediction for diffusion coefficients in water are 9.97% for the molecular-weight equation, 6.45% for the molal-volume equation. The mean absolute error for the diffusion coefficient in air is 5.79% for the molal-volume equation. Molecular weight is not a satisfactory correlating parameter for diffusion in air because two equations are necessary to describe the values in the data set. The best predictive equation for the liquid-film reference-substance parameter has a mean absolute error of 5.74%, with molal volume as the correlating parameter. The best equation for the gas-film parameter has a mean absolute error of 7.80%, with molecular weight as the correlating parameter.
Optimization of Scan Parameters to Reduce Acquisition Time for Diffusion Kurtosis Imaging at 1.5T.
Yokosawa, Suguru; Sasaki, Makoto; Bito, Yoshitaka; Ito, Kenji; Yamashita, Fumio; Goodwin, Jonathan; Higuchi, Satomi; Kudo, Kohsuke
2016-01-01
To shorten acquisition of diffusion kurtosis imaging (DKI) in 1.5-tesla magnetic resonance (MR) imaging, we investigated the effects of the number of b-values, diffusion direction, and number of signal averages (NSA) on the accuracy of DKI metrics. We obtained 2 image datasets with 30 gradient directions, 6 b-values up to 2500 s/mm(2), and 2 signal averages from 5 healthy volunteers and generated DKI metrics, i.e., mean, axial, and radial kurtosis (MK, K∥, and K⊥) maps, from various combinations of the datasets. These maps were estimated by using the intraclass correlation coefficient (ICC) with those from the full datasets. The MK and K⊥ maps generated from the datasets including only the b-value of 2500 s/mm(2) showed excellent agreement (ICC, 0.96 to 0.99). Under the same acquisition time and diffusion directions, agreement was better of MK, K∥, and K⊥ maps obtained with 3 b-values (0, 1000, and 2500 s/mm(2)) and 4 signal averages than maps obtained with any other combination of numbers of b-value and varied NSA. Good agreement (ICC > 0.6) required at least 20 diffusion directions in all the metrics. MK and K⊥ maps with ICC greater than 0.95 can be obtained at 1.5T within 10 min (b-value = 0, 1000, and 2500 s/mm(2); 20 diffusion directions; 4 signal averages; slice thickness, 6 mm with no interslice gap; number of slices, 12).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Y; Yin, F; Czito, B
2015-06-15
Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.Themore » technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15%,respectively.Mean M-ADC for ADC measured from 4D-DWI and M-ADC measured from FB-DWI were (2.29±0.04)*0.001*mm2/s and (3.80±0.01)*0.001*mm2/s,respectively.ADC value ground-truth is 2.24*0.001*mm2/s from the input of the simulation. Conclusion: A respiratory correlated 4D-DWI technique has been initially evaluated in phantoms and a human subject.Comparing to free breathing DWI,4D-DWI can lead to more accurate measurement of ADC.« less
Whole lung morphometry with 3D multiple b-value hyperpolarized gas MRI and compressed sensing.
Chan, Ho-Fung; Stewart, Neil J; Parra-Robles, Juan; Collier, Guilhem J; Wild, Jim M
2017-05-01
To demonstrate three-dimensional (3D) multiple b-value diffusion-weighted (DW) MRI of hyperpolarized 3 He gas for whole lung morphometry with compressed sensing (CS). A fully-sampled, two b-value, 3D hyperpolarized 3 He DW-MRI dataset was acquired from the lungs of a healthy volunteer and retrospectively undersampled in the k y and k z phase-encoding directions for CS simulations. Optimal k-space undersampling patterns were determined by minimizing the mean absolute error between reconstructed and fully-sampled 3 He apparent diffusion coefficient (ADC) maps. Prospective three-fold, undersampled, 3D multiple b-value 3 He DW-MRI datasets were acquired from five healthy volunteers and one chronic obstructive pulmonary disease (COPD) patient, and the mean values of maps of ADC and mean alveolar dimension (Lm D ) were validated against two-dimensional (2D) and 3D fully-sampled 3 He DW-MRI experiments. Reconstructed undersampled datasets showed no visual artifacts and good preservation of the main image features and quantitative information. A good agreement between fully-sampled and prospective undersampled datasets was found, with a mean difference of +3.4% and +5.1% observed in mean global ADC and Lm D values, respectively. These differences were within the standard deviation range and consistent with values reported from healthy and COPD lungs. Accelerated CS acquisition has facilitated 3D multiple b-value 3 He DW-MRI scans in a single breath-hold, enabling whole lung morphometry mapping. Magn Reson Med 77:1916-1925, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
3T diffusion-weighted MRI of the thyroid gland with reduced distortion: preliminary results
Nagala, S; Priest, A N; McLean, M A; Jani, P; Graves, M J
2013-01-01
Objective: Single-shot diffusion-weighted (DW) echo planar imaging (EPI), which is commonly used for imaging the thyroid, is characterised by severe blurring and distortion. The objectives of this work were: 1, to show that a reduced-field of view (r-FOV) DW EPI technique can improve image quality; and 2, to investigate the effect of different reconstruction strategies on the resulting apparent diffusion coefficients (ADCs). Methods: We implemented a single-shot, r-FOV DW EPI technique with a two-dimensional radiofrequency excitation pulse for DW imaging of the thyroid at 3T. Images were reconstructed using root sum of squares (SOS) and an optimal-B1 reconstruction (OBR). Phantom and in vivo experiments were performed to compare r-FOV and conventional full-FOV DW EPI with root SOS and OBR. Results: r-FOV with OBR substantially improved image quality at 3T. In phantoms, r-FOV gave more accurate ADCs than full-FOV. In vivo r-FOV always gave lower ADC values with respect to the full-FOV technique irrespective of the reconstruction used and whether only two or multiple b-values were used to compute the ADCs. Conclusion: r-FOV DW EPI can reduce image blurring and distortion at the expense of a low signal-to-noise ratio. OBR is a promising reconstruction technique for accurate ADC measurements in lower signal-to-noise ratio regimes, although further studies are needed to characterise its performance. Advances in knowledge: DW imaging of the thyroid at 3T could potentially benefit from r-FOV acquisition strategies, such as the r-FOV DW EPI technique proposed in this paper. PMID:23770539
Ahlawat, Shivani; Fayad, Laura M
2018-05-01
To determine the utility of "target sign" on diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC) mapping for peripheral nerve sheath tumor (PNST) characterization. This IRB-approved, HIPAA-compliant study retrospectively reviewed the MR imaging (comprised of T2- FS, DWI (b-values 50, 400, 800 s/mm 2 and ADC mapping), and static contrast-enhanced (CE) T1-W imaging) of 42 patients (mean age: 40 years (range 8-68 years), 48% (20/42) females) with 15 malignant PNSTs (MPNSTs) and 33 benign PNSTs (BPNSTs). MPNSTs were histologically confirmed while BPNSTs were histologically-proven or with stable clinical and imaging appearance for at least 12 months. Two radiologists assessed imaging characteristics (size, signal intensity, heterogeneity, perilesional edema or enhancement) and the presence or absence of "target sign," on each sequence. A "target sign" was defined as a biphasic pattern of peripheral hyperintensity and homogeneous central hypointensity. Descriptive statistics are reported. Cohen's κ statistic or interclass correlation coefficient (ICC) were used to evaluate interobserver agreement between two observers. Univariate and multiple logistic regression analysis were performed to identify MRI features with predictive values. MPNSTs were larger than BPNSTs (6.3 ± 2.5 cm vs 3.5 ± -2.1 cm, p = 0.0002), had perilesional edema (87%(13/15) vs 18%(6/33), p < 0.0001), heterogeneous enhancement (71%(10/14) vs 13%(4/31), p = 0.0001) and perilesional enhancement (79%(11/14) vs 18%(6/31), p = 0.0001), respectively. The "target sign" was present in: 24%(8/33) BPNSTs vs 0/15 MPNST on T2-FS (p = 0.26); 39%(13/33) BPNSTs vs 20%(3/15) MPNST on DWI using b-value = 50 s/mm 2 (p = 0.5); 55%(18/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 400 s/mm 2 (p = 0.002); 48%(16/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 800 s/mm 2 (p = 0.005) and 64%(21/33) benign vs 0/15 MPNST on ADC mapping(p < 0.0001). By CE-T1 imaging, 32%(10/31) BPNSTs and 7%(1/14) MPNST had a target sign(p = 0.07). The odds of an MPNST in cases with minimum ADC ≤ 1.0 × 10(-3) mm(2)/s are 150 times higher than in cases with ADC > 1.0 × 10(-3). In this explorative study, a "target sign" suggests a benign PNST and is more often visible on DWI using high b-values and ADC maps compared with anatomic sequences. Copyright © 2018 Elsevier B.V. All rights reserved.
Yan, Xu; Zhou, Minxiong; Ying, Lingfang; Yin, Dazhi; Fan, Mingxia; Yang, Guang; Zhou, Yongdi; Song, Fan; Xu, Dongrong
2013-01-01
Diffusion kurtosis imaging (DKI) is a new method of magnetic resonance imaging (MRI) that provides non-Gaussian information that is not available in conventional diffusion tensor imaging (DTI). DKI requires data acquisition at multiple b-values for parameter estimation; this process is usually time-consuming. Therefore, fewer b-values are preferable to expedite acquisition. In this study, we carefully evaluated various acquisition schemas using different numbers and combinations of b-values. Acquisition schemas that sampled b-values that were distributed to two ends were optimized. Compared to conventional schemas using equally spaced b-values (ESB), optimized schemas require fewer b-values to minimize fitting errors in parameter estimation and may thus significantly reduce scanning time. Following a ranked list of optimized schemas resulted from the evaluation, we recommend the 3b schema based on its estimation accuracy and time efficiency, which needs data from only 3 b-values at 0, around 800 and around 2600 s/mm2, respectively. Analyses using voxel-based analysis (VBA) and region-of-interest (ROI) analysis with human DKI datasets support the use of the optimized 3b (0, 1000, 2500 s/mm2) DKI schema in practical clinical applications. PMID:23735303
Shan, Yan; Zeng, Meng-su; Liu, Kai; Miao, Xi-Yin; Lin, Jiang; Fu, Cai xia; Xu, Peng-ju
2015-01-01
To evaluate the effect on image quality and intravoxel incoherent motion (IVIM) parameters of small hepatocellular carcinoma (HCC) from choice of either free-breathing (FB) or navigator-triggered (NT) diffusion-weighted (DW) imaging. Thirty patients with 37 small HCCs underwent IVIM DW imaging using 12 b values (0-800 s/mm) with 2 sequences: NT, FB. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) in small HCCs and liver parenchyma. Apparent diffusion coefficient (ADC) was also calculated. The acquisition time and image quality scores were assessed for 2 sequences. Independent sample t test was used to compare image quality, signal intensity ratio, IVIM parameters, and ADC values between the 2 sequences; reproducibility of IVIM parameters, and ADC values between 2 sequences was assessed with the Bland-Altman method (BA-LA). Image quality with NT sequence was superior to that with FB acquisition (P = 0.02). The mean acquisition time for FB scheme was shorter than that of NT sequence (6 minutes 14 seconds vs 10 minutes 21 seconds ± 10 seconds P < 0.01). The signal intensity ratio of small HCCs did not vary significantly between the 2 sequences. The ADC and IVIM parameters from the 2 sequences show no significant difference. Reproducibility of D*and f parameters in small HCC was poor (BA-LA: 95% confidence interval, -180.8% to 189.2% for D* and -133.8% to 174.9% for f). A moderate reproducibility of D and ADC parameters was observed (BA-LA: 95% confidence interval, -83.5% to 76.8% for D and -74.4% to 88.2% for ADC) between the 2 sequences. The NT DW imaging technique offers no advantage in IVIM parameters measurements of small HCC except better image quality, whereas FB technique offers greater confidence in fitted diffusion parameters for matched acquisition periods.
Miyazaki, Keiko; Jerome, Neil P; Collins, David J; Orton, Matthew R; d'Arcy, James A; Wallace, Toni; Moreno, Lucas; Pearson, Andrew D J; Marshall, Lynley V; Carceller, Fernando; Leach, Martin O; Zacharoulis, Stergios; Koh, Dow-Mu
2015-09-01
The objectives are to examine the reproducibility of functional MR imaging in children with solid tumours using quantitative parameters derived from diffusion-weighted (DW-) and dynamic contrast enhanced (DCE-) MRI. Patients under 16-years-of age with confirmed diagnosis of solid tumours (n = 17) underwent free-breathing DW-MRI and DCE-MRI on a 1.5 T system, repeated 24 hours later. DW-MRI (6 b-values, 0-1000 sec/mm(2)) enabled monoexponential apparent diffusion coefficient estimation using all (ADC0-1000) and only ≥100 sec/mm(2) (ADC100-1000) b-values. DCE-MRI was used to derive the transfer constant (K(trans)), the efflux constant (kep), the extracellular extravascular volume (ve), and the plasma fraction (vp), using a study cohort arterial input function (AIF) and the extended Tofts model. Initial area under the gadolinium enhancement curve and pre-contrast T1 were also calculated. Percentage coefficients of variation (CV) of all parameters were calculated. The most reproducible cohort parameters were ADC100-1000 (CV = 3.26%), pre-contrast T1 (CV = 6.21%), and K(trans) (CV = 15.23%). The ADC100-1000 was more reproducible than ADC0-1000, especially extracranially (CV = 2.40% vs. 2.78%). The AIF (n = 9) derived from this paediatric population exhibited sharper and earlier first-pass and recirculation peaks compared with the literature's adult population average. Free-breathing functional imaging protocols including DW-MRI and DCE-MRI are well-tolerated in children aged 6 - 15 with good to moderate measurement reproducibility. • Diffusion MRI protocol is feasible and well-tolerated in a paediatric oncology population. • DCE-MRI for pharmacokinetic evaluation is feasible and well tolerated in a paediatric oncology population. • Paediatric arterial input function (AIF) shows systematic differences from the adult population-average AIF. • Variation of quantitative parameters from paired functional MRI measurements were within 20%.
Diffusion-weighted imaging and diffusion tensor imaging of asymptomatic lumbar disc herniation.
Sakai, Toshinori; Miyagi, Ryo; Yamabe, Eiko; Fujinaga, Yasunari; N Bhatia, Nitin; Yoshioka, Hiroshi
2014-01-01
Diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) were performed on a healthy 31-year-old man with asymptomatic lumbar disc herniation. Although the left S1 nerve root was obviously entrapped by a herniated mass, neither DWI nor DTI showed any significant findings for the nerve root. Decreased apparent diffusion coefficient (ADC) values and increased fractional anisotropy (FA) values were found. These results are contrary to those in previously published studies of symptomatic patients, in which a combination of increased ADC and decreased FA seem to have a relationship with nerve injury and subsequent symptoms, such as leg pain or palsy. Our results seen in an asymptomatic subject suggest that the compressed nerve with no injury, such as edema, demyelination, or persistent axonal injury, may be indicated by a combination of decreased ADC and increased FA. ADC and FA could therefore be potential tools to elucidate the pathomechanism of radiculopathy.
Jabeen, S A; Cherukuri, Pavankumar; Mridula, Rukmini; Harshavardhana, K R; Gaddamanugu, Padmaja; Sarva, Sailaja; Meena, A K; Borgohain, Rupam; Jyotsna Rani, Y
2017-04-01
To study the frequency, imaging characteristics, and clinical predictors for development of periictal diffusion weighted MRI abnormalities. We prospectively analyzed electro clinical and imaging characteristic of adult patients with cluster of seizures or status epilepticus between November 2013 and November 2015, in whom the diffusion weighted imaging was done within 24h after the end of last seizure (clinical or electrographic). There were thirty patients who fulfilled the inclusion and exclusion criteria. Twenty patients (66%) had periictal MRI abnormalities. Nine patients (34%) did not have any MRI abnormality. All the patients with PMA had abnormalities on diffusion weighted imaging (DWI). Hippocampal abnormalities were seen in nine (53%), perisylvian in two (11.7%), thalamic in five (30%), splenium involvement in two (11.7%) and cortical involvement (temporo-occipital, parieto-occipital, temporo-parietal, fronto-parietal and fronto-temporal) in sixteen (94.1%) patients. Complete reversal of DWI changes was noted in sixteen (80%) patients and four (20%) patients showed partial resolution of MRI abnormalities. Mean duration of seizures was significantly higher among patients with PMA (59.11+20.97h) compared to those without MRI changes (27.33+9.33h) (p<0.001). Diffusion abnormalities on MRI are common in patients with cluster of seizures and status epilepticus and were highly concordant with clinical semiology and EEG activity. Patients with longer duration of seizures/status were more likely to have PMA. Copyright © 2017 Elsevier B.V. All rights reserved.
Malkyarenko, Dariya I; Chenevert, Thomas L
2014-12-01
To describe an efficient procedure to empirically characterize gradient nonlinearity and correct for the corresponding apparent diffusion coefficient (ADC) bias on a clinical magnetic resonance imaging (MRI) scanner. Spatial nonlinearity scalars for individual gradient coils along superior and right directions were estimated via diffusion measurements of an isotropicic e-water phantom. Digital nonlinearity model from an independent scanner, described in the literature, was rescaled by system-specific scalars to approximate 3D bias correction maps. Correction efficacy was assessed by comparison to unbiased ADC values measured at isocenter. Empirically estimated nonlinearity scalars were confirmed by geometric distortion measurements of a regular grid phantom. The applied nonlinearity correction for arbitrarily oriented diffusion gradients reduced ADC bias from 20% down to 2% at clinically relevant offsets both for isotropic and anisotropic media. Identical performance was achieved using either corrected diffusion-weighted imaging (DWI) intensities or corrected b-values for each direction in brain and ice-water. Direction-average trace image correction was adequate only for isotropic medium. Empiric scalar adjustment of an independent gradient nonlinearity model adequately described DWI bias for a clinical scanner. Observed efficiency of implemented ADC bias correction quantitatively agreed with previous theoretical predictions and numerical simulations. The described procedure provides an independent benchmark for nonlinearity bias correction of clinical MRI scanners.
Maiwald, Bettina; Lobsien, Donald; Kahn, Thomas; Stumpp, Patrick
2014-01-01
Objectives To compare 64-slice contrast-enhanced computed tomography (CT) with 3-Tesla magnetic resonance imaging (MRI) using Gd-EOB-DTPA for the diagnosis of hepatocellular carcinoma (HCC) and evaluate the utility of diffusion-weighted imaging (DWI) in this setting. Methods 3-phase-liver-CT was performed in fifty patients (42 male, 8 female) with suspected or proven HCC. The patients were subjected to a 3-Tesla-MRI-examination with Gd-EOB-DTPA and diffusion weighted imaging (DWI) at b-values of 0, 50 and 400 s/mm2. The apparent diffusion coefficient (ADC)-value was determined for each lesion detected in DWI. The histopathological report after resection or biopsy of a lesion served as the gold standard, and a surrogate of follow-up or complementary imaging techniques in combination with clinical and paraclinical parameters was used in unresected lesions. Diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values were evaluated for each technique. Results MRI detected slightly more lesions that were considered suspicious for HCC per patient compared to CT (2.7 versus 2.3, respectively). ADC-measurements in HCC showed notably heterogeneous values with a median of 1.2±0.5×10−3 mm2/s (range from 0.07±0.1 to 3.0±0.1×10−3 mm2/s). MRI showed similar diagnostic accuracy, sensitivity, and positive and negative predictive values compared to CT (AUC 0.837, sensitivity 92%, PPV 80% and NPV 90% for MRI vs. AUC 0.798, sensitivity 85%, PPV 79% and NPV 82% for CT; not significant). Specificity was 75% for both techniques. Conclusions Our study did not show a statistically significant difference in detection in detection of HCC between MRI and CT. Gd-EOB-DTPA-enhanced MRI tended to detect more lesions per patient compared to contrast-enhanced CT; therefore, we would recommend this modality as the first-choice imaging method for the detection of HCC and therapeutic decisions. However, contrast-enhanced CT was not inferior in our study, so that it can be a useful image modality for follow-up examinations. PMID:25375778
Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P
2016-04-01
Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.
Kartalis, Nikolaos; Manikis, Georgios C; Loizou, Louiza; Albiin, Nils; Zöllner, Frank G; Del Chiaro, Marco; Marias, Kostas; Papanikolaou, Nikolaos
2016-01-01
To compare two Gaussian diffusion-weighted MRI (DWI) models including mono-exponential and bi-exponential, with the non-Gaussian kurtosis model in patients with pancreatic ductal adenocarcinoma. After written informed consent, 15 consecutive patients with pancreatic ductal adenocarcinoma underwent free-breathing DWI (1.5T, b-values: 0, 50, 150, 200, 300, 600 and 1000 s/mm 2 ). Mean values of DWI-derived metrics ADC, D, D*, f, K and D K were calculated from multiple regions of interest in all tumours and non-tumorous parenchyma and compared. Area under the curve was determined for all metrics. Mean ADC and D K showed significant differences between tumours and non-tumorous parenchyma (both P < 0.001). Area under the curve for ADC, D, D*, f, K, and D K were 0.77, 0.52, 0.53, 0.62, 0.42, and 0.84, respectively. ADC and D K could differentiate tumours from non-tumorous parenchyma with the latter showing a higher diagnostic accuracy. Correction for kurtosis effects has the potential to increase the diagnostic accuracy of DWI in patients with pancreatic ductal adenocarcinoma.
Lee, J S; Kim, Y K; Jeong, W K; Choi, D; Lee, W J
2015-04-01
To assess the value of section-selection gradient reversal (SSGR) in liver diffusion-weighted imaging (DWI) by comparing it to conventional DWI with an emphasis on chemical shift artefacts and lesion conspicuity. Forty-eight patients (29 men and 19 women; age range 33-80 years) with 48 liver lesions underwent two DWI examinations using spectral presaturation with inversion recovery fat suppression with and without SSGR at 3 T. Two reviewers evaluated each DWI (b = 100 and b = 800 image) with respect to chemical shift artefacts and liver lesion conspicuity using five-point scales and performed pairwise comparisons between the two DWIs. The signal-to-noise ratio (SNR) of the liver and the lesion and the lesion-liver contrast-to-noise ratio (CNR) were also calculated. SSGR-DWI was significantly better than conventional DWI with respect to chemical shift artefacts and lesion conspicuity in both separate reviews and pairwise comparisons (p < 0.05). There were significant differences in the SNR of the liver (b = 100 and b = 800 images) and lesion (b = 800) between SSGR-DWI and conventional DWI (p < 0.05). Applying the SSGR method to DWI using SPIR fat suppression at 3 T could significantly reduce chemical shift artefacts without incurring additional acquisition time or SNR penalties, which leads to increased conspicuity of focal liver lesions. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Jiang, T; Xu, J H; Zou, Y; Chen, R; Peng, L R; Zhou, Z D; Yang, M
2017-06-01
To evaluate the application of qualitative and quantitative diffusion-weighted imaging (DWI) in predicting the histological grade of hepatocellular carcinoma (HCC). Two hundred and fifty-four patients with pathologically confirmed HCC who underwent hepatic DWI on a 1.5-T platform (b = 0, 600 s/mm 2 ) were evaluated retrospectively. HCCs were divided into well-, moderately, and poorly differentiated groups. The relationships between naked-eye signal intensity (SI), SI values, apparent diffusion coefficient (ADC) values on DWI, and the histopathological differentiation of HCC were analysed. Receiver operating characteristic (ROC) curves were drawn to determine the optimal operating points (OOPs) of the SI and ADC values to predict the tumour grade. A weak negative correlation (r=-0.350, p<0.05) was obtained between naked-eye SI and histological grade. There was a significant difference in mean SI values between well- (68.32±31.71) and moderately (102.39±45.55)/poorly (114.55±32.15) differentiated HCC but not between moderately and poorly differentiated HCC. The OOP of the SI value by ROC curve analysis was 66.5 to predict well-differentiated HCC. The mean ADC values of well-, moderately, and poorly differentiated HCC were 1.67±0.13×10 -3 , 1.31±0.16×10 -3 , and 1.08±0.11×10 -3 mm 2 /s, respectively, with significant differences between any two combinations of groups. The OOPs of ADC to diagnose well- and poorly differentiated HCC were 1.5×10 -3 and 1.24×10 -3 mm 2 /s, respectively. Qualitative and quantitative SI and ADC values at DWI may be useful to estimate the histological grade of HCC preoperatively and non-invasively. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Kwon, Mi-Ri; Kim, Chan Kyo; Kim, Jae-Hun
2017-11-01
To investigate the variability of diffusion-weighted imaging (DWI) interpretation of Prostate Imaging Reporting and Data System (PI-RADS) version 2 (v2) in evaluating prostate cancer (PCa). 154 patients with PCa underwent multiparametric 3T MRI, followed by radical prostatectomy. DWI with different b values (b = 0, 100, 1000 and 1500 s mm - 2 ) was obtained. Using the PI-RADS v2, two radiologists independently scored suspicious lesions in each patient and compared DWI of b = 1000 (DWI 1000 ) with 1500 (DWI 1500 ) s mm - 2 . On DWI 1000 and DWI 1500 , the intermethod and interobserver agreements of DWI scores were excellent in all patients (κ ≥ 0.873). In each peripheral zone and transition zone DWI scores, both observers showed excellent intermethod agreement between DWI 1000 and DWI 1500 (κ ≥ 0.897), and interobserver agreement for DWI 1000 and DWI 1500 was good to excellent (κ ≥ 0.796). For estimating clinically significant cancer, the area under receiver operating characteristics curves of DWI 1000 and DWI 1500 were 0.710 and 0.724 for observer 1 (p = 0.11), and 0.649 and 0.656 for observer 2 (p = 0.12), respectively. The PI-RADS v2 scoring at 3T shows excellent agreement between DWI 1000 and DWI 1500 in evaluating PCa, with excellent inter-observer agreement. Advance in knowledge: DWI using b = 1000 s mm -2 instead of b = 1500 s mm -2 reduces examination time or image distortion, with improved the signal-to-noise ratio.
Karampinos, Dimitrios C.; Banerjee, Suchandrima; King, Kevin F.; Link, Thomas M.; Majumdar, Sharmila
2011-01-01
Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can non-invasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion weighted (DW)-EPI can be hindered by the inherently low SNR of muscle DW-EPI due to the short muscle T2 and the high sensitivity of single-shot EPI to off-resonance effects and T2* blurring. In the present work, eddy-current compensated diffusion-weighted stimulated echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and reduce the sensitivity to distortions and T2* blurring in high resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed for optimizing the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B0-induced distortions, T2* blurring effects and tissue incoherent motion effects. Based on the selected parameters in a high resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In vivo results show that high resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T2* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from reducing partial volume effects on resolving multi-pennate muscles and muscles with small cross sections in calf muscle DTI. PMID:22081519
Fusion of MRIs and CT scans for surgical treatment of cholesteatoma of the middle ear in children.
Plouin-Gaudon, Isabelle; Bossard, Denis; Ayari-Khalfallah, Sonia; Froehlich, Patrick
2010-09-01
To evaluate the efficiency of diffusion-weighted magnetic resonance imaging (MRI) and high-resolution computed tomographic (CT) scan coregistration in predicting and adequately locating primary or recurrent cholesteatoma in children. Prospective study. Tertiary care university hospital. Ten patients aged 2 to 17 years (mean age, 8.5 years) with cholesteatoma of the middle ear, some of which were previously treated, were included for follow-up with systematic CT scanning and MRI between 2007 and 2008. Computed tomographic scanning was performed on a Siemens Somaton 128 (0.5/0.2-mm slices reformatted in 0.5/0.3-mm images). Fine cuts were obtained parallel and perpendicular to the lateral semicircular canal in each ear (100 × 100-mm field of view). Magnetic resonance imaging was undertaken on a Siemens Avanto 1.5T unit, with a protocol adapted for young children. Diffusion-weighted imaging was acquired using a single-shot turbo spin-echo mode. To allow for diagnosis and localization of the cholesteatoma, CT and diffusion-weighted MRIs were fused for each case. In 10 children, fusion technique allowed for correct diagnosis and precise localization (hypotympanum, epitympanum, mastoid recess, and attical space) as confirmed by subsequent standard surgery (positive predictive value, 100%). In 3 cases, the surgical approach was adequately determined from the fusion results. Lesion sizes on the CT-MRI fusion corresponded with perioperative findings. Recent developments in imaging techniques have made diffusion-weighted MRI more effective for detecting recurrent cholesteatoma. The major drawback of this technique, however, has been its poor anatomical and spatial discrimination. Fusion imaging using high-resolution CT and diffusion-weighted MRI appears to be a promising technique for both the diagnosis and precise localization of cholesteatomas. It provides useful information for surgical planning and, furthermore, is easy to use in pediatric cases.
Guo, Yuan; Kong, Qing-Cong; Zhu, Ye-Qing; Liu, Zhen-Zhen; Peng, Ling-Rong; Tang, Wen-Jie; Yang, Rui-Meng; Xie, Jia-Jun; Liu, Chun-Ling
2018-02-01
To evaluate the utility of the whole-lesion histogram apparent diffusion coefficient (ADC) for characterizing the heterogeneity of mucinous breast carcinoma (MBC) and to determine which ADC metrics may help to best differentiate subtypes of MBC. This retrospective study involved 52 MBC patients, including 37 pure MBC (PMBC) and 15 mixed MBC (MMBC). The PMBC patients were subtyped into PMBC-A (20 cases) and PMBC-B (17 cases) groups. All patients underwent preoperative diffusion-weighted imaging (DWI) at 1.5T and the whole-lesion ADC assessments were generated. Histogram-derived ADC parameters were compared between PMBC vs. MMBC and PMBC-A vs. PMBC-B, and receiver operating characteristic (ROC) curve analysis was used to determine optimal histogram parameters for differentiating these groups. The PMBC group exhibited significantly higher ADC values for the mean (P = 0.004), 25 th (P = 0.004), 50 th (P = 0.004), 75 th (P = 0.006), and 90 th percentiles (P = 0.013) and skewness (P = 0.021) than did the MMBC group. The 25 th percentile of ADC values achieved the highest area under the curve (AUC) (0.792), with a cutoff value of 1.345 × 10 -3 mm 2 /s, in distinguishing PMBC and MMBC. The PMBC-A group showed significantly higher ADC values for the mean (P = 0.049), 25 th (P = 0.015), and 50 th (P = 0.026) percentiles and skewness (P = 0.004) than did the PMBC-B group. The 25 th percentile of the ADC cutoff value (1.476 × 10 -3 mm 2 /s) demonstrated the best AUC (0.837) among the ADC values for distinguishing PMBC-A and PMBC-B. Whole-lesion ADC histogram analysis enables comprehensive evaluation of an MBC in its entirety and differentiating subtypes of MBC. Thus, it may be a helpful and supportive tool for conventional MRI. 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:391-400. © 2017 International Society for Magnetic Resonance in Medicine.
Bickel, Hubert; Pinker, Katja; Polanec, Stephan; Magometschnigg, Heinrich; Wengert, Georg; Spick, Claudio; Bogner, Wolfgang; Bago-Horvath, Zsuzsanna; Helbich, Thomas H; Baltzer, Pascal
2017-05-01
To investigate the influence of region-of-interest (ROI) placement and different apparent diffusion coefficient (ADC) parameters on ADC values, diagnostic performance, reproducibility and measurement time in breast tumours. In this IRB-approved, retrospective study, 149 histopathologically proven breast tumours (109 malignant, 40 benign) in 147 women (mean age 53.2) were investigated. Three radiologists independently measured minimum, mean and maximum ADC, each using three ROI placement approaches:1 - small 2D-ROI, 2 - large 2D-ROI and 3 - 3D-ROI covering the whole lesion. One reader performed all measurements twice. Median ADC values, diagnostic performance, reproducibility, and measurement time were calculated and compared between all combinations of ROI placement approaches and ADC parameters. Median ADC values differed significantly between the ROI placement approaches (p < .001). Minimum ADC showed the best diagnostic performance (AUC .928-.956), followed by mean ADC obtained from 2D ROIs (.926-.94). Minimum and mean ADC showed high intra- (ICC .85-.94) and inter-reader reproducibility (ICC .74-.94). Median measurement time was significantly shorter for the 2D ROIs (p < .001). ROI placement significantly influences ADC values measured in breast tumours. Minimum and mean ADC acquired from 2D-ROIs are useful for the differentiation of benign and malignant breast lesions, and are highly reproducible, with rapid measurement. • Region of interest placement significantly influences apparent diffusion coefficient of breast tumours. • Minimum and mean apparent diffusion coefficient perform best and are reproducible. • 2D regions of interest perform best and provide rapid measurement times.
Tudela, Raúl; Muñoz-Moreno, Emma; López-Gil, Xavier; Soria, Guadalupe
2017-01-01
Diffusion-weighted imaging (DWI) quantifies water molecule diffusion within tissues and is becoming an increasingly used technique. However, it is very challenging as correct quantification depends on many different factors, ranging from acquisition parameters to a long pipeline of image processing. In this work, we investigated the influence of voxel geometry on diffusion analysis, comparing different acquisition orientations as well as isometric and anisometric voxels. Diffusion-weighted images of one rat brain were acquired with four different voxel geometries (one isometric and three anisometric in different directions) and three different encoding orientations (coronal, axial and sagittal). Diffusion tensor scalar measurements, tractography and the brain structural connectome were analyzed for each of the 12 acquisitions. The acquisition direction with respect to the main magnetic field orientation affected the diffusion results. When the acquisition slice-encoding direction was not aligned with the main magnetic field, there were more artifacts and a lower signal-to-noise ratio that led to less anisotropic tensors (lower fractional anisotropic values), producing poorer quality results. The use of anisometric voxels generated statistically significant differences in the values of diffusion metrics in specific regions. It also elicited differences in tract reconstruction and in different graph metric values describing the brain networks. Our results highlight the importance of taking into account the geometric aspects of acquisitions, especially when comparing diffusion data acquired using different geometries.
Stephen, Renu M.; Jha, Abhinav K.; Roe, Denise J.; Trouard, Theodore P.; Galons, Jean-Philippe; Kupinski, Matthew A.; Frey, Georgette; Cui, Haiyan; Squire, Scott; Pagel, Mark D.; Rodriguez, Jeffrey J.; Gillies, Robert J.; Stopeck, Alison T.
2015-01-01
Purpose To assess the value of semi-automated segmentation applied to diffusion MRI for predicting the therapeutic response of liver metastasis. Methods Conventional diffusion weighted magnetic resonance imaging (MRI) was performed using b-values of 0, 150, 300 and 450 s/mm2 at baseline and days 4, 11 and 39 following initiation of a new chemotherapy regimen in a pilot study with 18 women with 37 liver metastases from primary breast cancer. A semi-automated segmentation approach was used to identify liver metastases. Linear regression analysis was used to assess the relationship between baseline values of the apparent diffusion coefficient (ADC) and change in tumor size by day 39. Results A semi-automated segmentation scheme was critical for obtaining the most reliable ADC measurements. A statistically significant relationship between baseline ADC values and change in tumor size at day 39 was observed for minimally treated patients with metastatic liver lesions measuring 2–5 cm in size (p = 0.002), but not for heavily treated patients with the same tumor size range (p = 0.29), or for tumors of smaller or larger sizes. ROC analysis identified a baseline threshold ADC value of 1.33 μm2/ms as 75% sensitive and 83% specific for identifying non-responding metastases in minimally treated patients with 2–5 cm liver lesions. Conclusion Quantitative imaging can substantially benefit from a semi-automated segmentation scheme. Quantitative diffusion MRI results can be predictive of therapeutic outcome in selected patients with liver metastases, but not for all liver metastases, and therefore should be considered to be a restricted biomarker. PMID:26284600
Stephen, Renu M; Jha, Abhinav K; Roe, Denise J; Trouard, Theodore P; Galons, Jean-Philippe; Kupinski, Matthew A; Frey, Georgette; Cui, Haiyan; Squire, Scott; Pagel, Mark D; Rodriguez, Jeffrey J; Gillies, Robert J; Stopeck, Alison T
2015-12-01
To assess the value of semi-automated segmentation applied to diffusion MRI for predicting the therapeutic response of liver metastasis. Conventional diffusion weighted magnetic resonance imaging (MRI) was performed using b-values of 0, 150, 300 and 450s/mm(2) at baseline and days 4, 11 and 39 following initiation of a new chemotherapy regimen in a pilot study with 18 women with 37 liver metastases from primary breast cancer. A semi-automated segmentation approach was used to identify liver metastases. Linear regression analysis was used to assess the relationship between baseline values of the apparent diffusion coefficient (ADC) and change in tumor size by day 39. A semi-automated segmentation scheme was critical for obtaining the most reliable ADC measurements. A statistically significant relationship between baseline ADC values and change in tumor size at day 39 was observed for minimally treated patients with metastatic liver lesions measuring 2-5cm in size (p=0.002), but not for heavily treated patients with the same tumor size range (p=0.29), or for tumors of smaller or larger sizes. ROC analysis identified a baseline threshold ADC value of 1.33μm(2)/ms as 75% sensitive and 83% specific for identifying non-responding metastases in minimally treated patients with 2-5cm liver lesions. Quantitative imaging can substantially benefit from a semi-automated segmentation scheme. Quantitative diffusion MRI results can be predictive of therapeutic outcome in selected patients with liver metastases, but not for all liver metastases, and therefore should be considered to be a restricted biomarker. Copyright © 2015 Elsevier Inc. All rights reserved.
Chen, T; Li, Y; Lu, S-S; Zhang, Y-D; Wang, X-N; Luo, C-Y; Shi, H-B
2017-11-01
To evaluate the diagnostic performance of histogram analysis of diffusion kurtosis magnetic resonance imaging (DKI) and standard diffusion-weighted imaging (DWI) in discriminating tumour grades of endometrial carcinoma (EC). Seventy-three patients with EC were included in this study. The apparent diffusion coefficient (ADC) value from standard DWI, apparent diffusion for Gaussian distribution (D app ), and apparent kurtosis coefficient (K app ) from DKI were acquired using a 3 T magnetic resonance imaging (MRI) system. The measurement was based on an entire-tumour analysis. Histogram parameters (D app , K app , and ADC) were compared between high-grade (grade 3) and low-grade (grade 1 and 2) tumours. The diagnostic performance of imaging parameters for discriminating high- from low-grade tumours was analysed using a receiver operating characteristic curve (ROC). The area under the ROC curve (AUC) of the 10th percentile of D app , 90th percentile of K app and 10th percentile of ADC were higher than other parameters in distinguishing high-grade tumours from low-grade tumours (AUC=0.821, 0.891 and 0.801, respectively). The combination of 10th percentile of D app and 90th percentile of K app improved the AUC to 0.901, which was significantly higher than that of the 10th percentile of ADC (0.810, p=0.0314) in differentiating high- from low-grade EC. Entire-tumour volume histogram analysis of DKI and standard DWI were feasible for discriminating histological tumour grades of EC. DKI was relatively better than DWI in distinguishing high-grade from low-grade tumour in EC. Copyright © 2017. Published by Elsevier Ltd.
MGH-USC Human Connectome Project datasets with ultra-high b-value diffusion MRI.
Fan, Qiuyun; Witzel, Thomas; Nummenmaa, Aapo; Van Dijk, Koene R A; Van Horn, John D; Drews, Michelle K; Somerville, Leah H; Sheridan, Margaret A; Santillana, Rosario M; Snyder, Jenna; Hedden, Trey; Shaw, Emily E; Hollinshead, Marisa O; Renvall, Ville; Zanzonico, Roberta; Keil, Boris; Cauley, Stephen; Polimeni, Jonathan R; Tisdall, Dylan; Buckner, Randy L; Wedeen, Van J; Wald, Lawrence L; Toga, Arthur W; Rosen, Bruce R
2016-01-01
The MGH-USC CONNECTOM MRI scanner housed at the Massachusetts General Hospital (MGH) is a major hardware innovation of the Human Connectome Project (HCP). The 3T CONNECTOM scanner is capable of producing a magnetic field gradient of up to 300 mT/m strength for in vivo human brain imaging, which greatly shortens the time spent on diffusion encoding, and decreases the signal loss due to T2 decay. To demonstrate the capability of the novel gradient system, data of healthy adult participants were acquired for this MGH-USC Adult Diffusion Dataset (N=35), minimally preprocessed, and shared through the Laboratory of Neuro Imaging Image Data Archive (LONI IDA) and the WU-Minn Connectome Database (ConnectomeDB). Another purpose of sharing the data is to facilitate methodological studies of diffusion MRI (dMRI) analyses utilizing high diffusion contrast, which perhaps is not easily feasible with standard MR gradient system. In addition, acquisition of the MGH-Harvard-USC Lifespan Dataset is currently underway to include 120 healthy participants ranging from 8 to 90 years old, which will also be shared through LONI IDA and ConnectomeDB. Here we describe the efforts of the MGH-USC HCP consortium in acquiring and sharing the ultra-high b-value diffusion MRI data and provide a report on data preprocessing and access. We conclude with a demonstration of the example data, along with results of standard diffusion analyses, including q-ball Orientation Distribution Function (ODF) reconstruction and tractography. Copyright © 2015 Elsevier Inc. All rights reserved.
Karampinos, Dimitrios C; Banerjee, Suchandrima; King, Kevin F; Link, Thomas M; Majumdar, Sharmila
2012-05-01
Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can noninvasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion-weighted echo planar imaging (DW-EPI) can be hindered by the inherently low signal-to-noise ratio (SNR) of muscle DW-EPI because of the short muscle T(2) and the high sensitivity of single-shot EPI to off-resonance effects and T(2)* blurring. In this article, eddy current-compensated diffusion-weighted stimulated-echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and to reduce the sensitivity to distortions and T(2)* blurring in high-resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed to optimize the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B(0)-induced distortions, T(2)* blurring effects and tissue incoherent motion effects. On the basis of the selected parameters in a high-resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In vivo results show that high-resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T(2)* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from a reduction in partial volume effects for resolving multi-pennate muscles and muscles with small cross-sections in calf muscle DTI. Copyright © 2011 John Wiley & Sons, Ltd.
Martel Villagrán, J; Bueno Horcajadas, Á; Pérez Fernández, E; Martín Martín, S
2015-01-01
To determine the ability of MRI to distinguish between benign and malignant vertebral lesions. We included 85 patients and studied a total of 213 vertebrae (both pathologic and normal). For each vertebra, we determined whether the lesion was hypointense in T1-weighted sequences and whether it was hyperintense in STIR and in diffusion-weighted sequences. We calculated the in-phase/out-of-phase quotient and the apparent diffusion coefficient for each vertebra. We combined parameters from T1-weighted, diffusion-weighted, and STIR sequences to devise a formula to distinguish benign from malignant lesions. The group comprised 60 (70.6%) women and 25 (29.4%) men with a mean age of 67±13.5 years (range, 33-90 y). Of the 85 patients, 26 (30.6%) had a known primary tumor. When the lesion was hypointense on T1-weighted sequences, hyperintense on STIR and diffusion-weighted sequences, and had a signal intensity quotient greater than 0.8, the sensitivity was 97.2%, the specificity was 90%, and the diagnostic accuracy was 91.2%. If the patient had a known primary tumor, these values increased to 97.2%, 99.4%, and 99%, respectively. Benign lesions can be distinguished from malignant lesions if we combine the information from T1-weighted, STIR, and diffusion-weighted sequences together with the in-phase/out-of-phase quotient of the lesion detected in the vertebral body on MRI. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Jeon, Ji Young; Lee, Min Hee; Lee, Sang Hoon; Shin, Myung Jin
2016-01-01
Objective: To evaluate the usefulness of adding diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping to conventional 3.0-T MRI to differentiate between benign and malignant superficial soft-tissue masses (SSTMs). Methods: The institutional review board approved this study and informed consent was waived. The authors retrospectively analyzed conventional MR images including diffusion-weighted images (b-values: 0, 400, 800 s mm−2) in 60 histologically proven SSTMs (35 benign and 25 malignant) excluding lipomas. Two radiologists independently evaluated the conventional MRI alone and again with the additional DWI for the evaluation of malignant masses. The mean ADC values measured within an entire mass and the contrast-enhancing solid portion were used for quantitative analysis. Diagnostic performances were compared using receiver-operating characteristic analysis. Results: For an inexperienced reader, using only conventional MRI, the sensitivity, specificity and accuracy were 84%, 80% and 81.6%, respectively. When combining conventional MRI and DWI, the sensitivity, specificity and accuracy were 96%, 85.7% and 90%, respectively. Additional DWI influenced the improvement of the rate of correct diagnosis by 8.3% (5/60). For an experienced reader, additional DWI revealed the same accuracy of 86.7% without added value on the correct diagnosis. The group mean ADCs of malignant SSTMs were significantly lower than that of benign SSTMs (p < 0.001). The best diagnostic performance with respect to differentiation of SSTMs could be obtained when conventional MRI was assessed in combination with DWI. Conclusion: Adding qualitative and quantitative DWI to conventional MRI can improve the diagnostic performance for the differentiation between benign and malignant SSTMs. Advances in knowledge: Because the imaging characteristics of many malignant superficial soft-tissue lesions overlap with those of benign ones, inadequate surgical resection due to misinterpretation of MRI often occurs. Adding DWI to conventional MRI yields greater diagnostic performances [area under the receiver-operating characteristic curve (AUC), 0.83–0.99] than does the use of conventional MRI alone (AUC, 0.71–0.93) in the evaluation of malignant superficial masses by inexperienced readers. PMID:26892266
Kim, Bum Joon; Kim, Yong-Hwan; Kim, Yeon-Jung; Ahn, Sung Ho; Lee, Deok Hee; Kwon, Sun U; Kim, Sang Joon; Kim, Jong S; Kang, Dong-Wha
2014-09-01
Diffusion-weighted image fluid-attenuated inversion recovery (FLAIR) mismatch has been considered to represent ischemic lesion age. However, the inter-rater agreement of diffusion-weighted image FLAIR mismatch is low. We hypothesized that color-coded images would increase its inter-rater agreement. Patients with ischemic stroke <24 hours of a clear onset were retrospectively studied. FLAIR signal change was rated as negative, subtle, or obvious on conventional and color-coded FLAIR images based on visual inspection. Inter-rater agreement was evaluated using κ and percent agreement. The predictive value of diffusion-weighted image FLAIR mismatch for identification of patients <4.5 hours of symptom onset was evaluated. One hundred and thirteen patients were enrolled. The inter-rater agreement of FLAIR signal change improved from 69.9% (k=0.538) with conventional images to 85.8% (k=0.754) with color-coded images (P=0.004). Discrepantly rated patients on conventional, but not on color-coded images, had a higher prevalence of cardioembolic stroke (P=0.02) and cortical infarction (P=0.04). The positive predictive value for patients <4.5 hours of onset was 85.3% and 71.9% with conventional and 95.7% and 82.1% with color-coded images, by each rater. Color-coded FLAIR images increased the inter-rater agreement of diffusion-weighted image FLAIR recovery mismatch and may ultimately help identify unknown-onset stroke patients appropriate for thrombolysis. © 2014 American Heart Association, Inc.
van Heeswijk, Miriam M; Lambregts, Doenja M J; Maas, Monique; Lahaye, Max J; Ayas, Z; Slenter, Jos M G M; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H
2017-06-01
The apparent diffusion coefficient (ADC) is a potential prognostic imaging marker in rectal cancer. Typically, mean ADC values are used, derived from precise manual whole-volume tumor delineations by experts. The aim was first to explore whether non-precise circular delineation combined with histogram analysis can be a less cumbersome alternative to acquire similar ADC measurements and second to explore whether histogram analyses provide additional prognostic information. Thirty-seven patients who underwent a primary staging MRI including diffusion-weighted imaging (DWI; b0, 25, 50, 100, 500, 1000; 1.5 T) were included. Volumes-of-interest (VOIs) were drawn on b1000-DWI: (a) precise delineation, manually tracing tumor boundaries (2 expert readers), and (b) non-precise delineation, drawing circular VOIs with a wide margin around the tumor (2 non-experts). Mean ADC and histogram metrics (mean, min, max, median, SD, skewness, kurtosis, 5th-95th percentiles) were derived from the VOIs and delineation time was recorded. Measurements were compared between the two methods and correlated with prognostic outcome parameters. Median delineation time reduced from 47-165 s (precise) to 21-43 s (non-precise). The 45th percentile of the non-precise delineation showed the best correlation with the mean ADC from the precise delineation as the reference standard (ICC 0.71-0.75). None of the mean ADC or histogram parameters showed significant prognostic value; only the total tumor volume (VOI) was significantly larger in patients with positive clinical N stage and mesorectal fascia involvement. When performing non-precise tumor delineation, histogram analysis (in specific 45th ADC percentile) may be used as an alternative to obtain similar ADC values as with precise whole tumor delineation. Histogram analyses are not beneficial to obtain additional prognostic information.
Yanagisawa, O; Fukubayashi, T
2010-11-01
To evaluate the effect of local cooling on the diffusion of water molecules and perfusion within muscle at different cooling temperatures. Magnetic resonance diffusion-weighted (DW) images of the leg (seven males) were obtained before and after 30 min cooling (0, 10, and 20°C), and after a 30 min recovery period. Two types of apparent diffusion coefficient (ADC; ADC1, reflecting both water diffusion and perfusion within muscle, and ADC2, approximating the true water diffusion coefficient) of the ankle dorsiflexors were calculated from DW images. T2-weighted images were also obtained to calculate T2 values of the ankle dorsiflexors. The skin temperature was measured before, during, and after cooling. Both ADC values significantly decreased after cooling under all cooling conditions; the rate of decrease depended on the cooling temperature used (ADC1: -36% at 0°C, -27.8% at 10°C, and -22.6% at 20°C; ADC2: -26% at 0°C, -21.1% at 10°C, and -14.6% at 20°C). These significant decreases were maintained during the recovery period. Conversely, the T2 value showed no significant changes. Under all cooling conditions, skin temperature significantly decreased during cooling; the rate of decrease depended on the cooling temperature used (-74.8% at 0°C, -51.1% at 10°C, and -26.8% at 20°C). Decreased skin temperatures were not restored to pre-cooling values during the recovery period under any cooling conditions. Local cooling decreased the water diffusion and perfusion within muscle with decreased skin temperature; the rates of decrease depended on the cooling temperature used. These decreases were maintained for 30 min after cooling. Copyright © 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Guo, Tan; Chen, Juan; Wu, Bing; Zheng, Dandan; Jiao, Sheng; Song, Yan; Chen, Min
2017-04-01
To investigate the hypothesis that the intravoxel incoherent motion (IVIM) diffusion-weighted imaging may depict microcirculation of meniscus and the perfusion changes in meniscal disorder. Fifty patients received diffusion-weighted MRI with multiple b-values ranging from 0 to 400 s/mm 2 . The four horns of the menisci were divided into normal, degenerated, and torn groups. IVIM parameters including perfusion fraction (f), pseudo-diffusion coefficient (D*), true diffusion coefficient (D), and the product of f and D* (f D*) of normal meniscal red zone and white zone were derived and compared for microcirculation changes of normal, degenerated, and torn posterior horn of the medial meniscus (PMM). The parameters between red and white zones among the groups were compared. Significant differences were considered when P < 0.05. Mean f and fD* were significantly higher in the red zone than those in the white zone for the normal four meniscal horns (P < 0.05), whereas D* (P = 0.882, 0.011, 0.593, and 0.33) and D (P = 0.186, 0.099, 0.767, and 0.041) did not significantly differ between the two zones. Among the normal, degenerated, and torn PMM, f was observed to be lower in the red zone of torn horns as compared to the normal horns (P = 0.013). D*, fD*, and D did not exhibit statistically significant difference among different groups (P = 0.353, 0.661, and 0.327, respectively). This hypothesis driven work shows that IVIM imaging is able to depict microcirculation of meniscus and the perfusion changes in meniscal disorder. 3 J. Magn. Reson. Imaging 2017;45:1090-1096. © 2016 International Society for Magnetic Resonance in Medicine.
Grabner, Günther; Kiesel, Barbara; Wöhrer, Adelheid; Millesi, Matthias; Wurzer, Aygül; Göd, Sabine; Mallouhi, Ammar; Knosp, Engelbert; Marosi, Christine; Trattnig, Siegfried; Wolfsberger, Stefan; Preusser, Matthias; Widhalm, Georg
2017-04-01
To investigate the value of local image variance (LIV) as a new technique for quantification of hypointense microvascular susceptibility-weighted imaging (SWI) structures at 7 Tesla for preoperative glioma characterization. Adult patients with neuroradiologically suspected diffusely infiltrating gliomas were prospectively recruited and 7 Tesla SWI was performed in addition to standard imaging. After tumour segmentation, quantification of intratumoural SWI hypointensities was conducted by the SWI-LIV technique. Following surgery, the histopathological tumour grade and isocitrate dehydrogenase 1 (IDH1)-R132H mutational status was determined and SWI-LIV values were compared between low-grade gliomas (LGG) and high-grade gliomas (HGG), IDH1-R132H negative and positive tumours, as well as gliomas with significant and non-significant contrast-enhancement (CE) on MRI. In 30 patients, 9 LGG and 21 HGG were diagnosed. The calculation of SWI-LIV values was feasible in all tumours. Significantly higher mean SWI-LIV values were found in HGG compared to LGG (92.7 versus 30.8; p < 0.0001), IDH1-R132H negative compared to IDH1-R132H positive gliomas (109.9 versus 38.3; p < 0.0001) and tumours with significant CE compared to non-significant CE (120.1 versus 39.0; p < 0.0001). Our data indicate that 7 Tesla SWI-LIV might improve preoperative characterization of diffusely infiltrating gliomas and thus optimize patient management by quantification of hypointense microvascular structures. • 7 Tesla local image variance helps to quantify hypointense susceptibility-weighted imaging structures. • SWI-LIV is significantly increased in high-grade and IDH1-R132H negative gliomas. • SWI-LIV is a promising technique for improved preoperative glioma characterization. • Preoperative management of diffusely infiltrating gliomas will be optimized.
Fu, Zhan-Zhao; Peng, Yong; Cao, Li-Yan; Chen, Yan-Sheng; Li, Kun; Fu, Bao-Hong
2015-06-01
We investigated the clinical significance of apparent diffusion coefficient (ADC) values in diffusion-weighted magnetic resonance imaging (DWI) in monitoring the efficacy of radiotherapy (RT) and chemotherapy (CT) treatments in cervical cancer. In order to identify relevant high quality clinical cohort studies reporting the use of DWI in cervical cancers, the following electronic databases in English and Chinese languages were comprehensively searched: MEDLINE, Science Citation Index database, Cochrane Library Database, PubMed, Embase, CINAHL, and Current Contents Index; Chinese Biomedical Database, Chinese Journal Full-Text Database. All selected studies were published prior to March 2014, and data extracted from these studies were analyzed using STATA 12.0 statistical software. We initially retrieved 196 articles (79 Chinese articles and 117 English articles) through database searches and finally selected sixteen cohort studies for this meta-analysis. The 16 studies contained a combined total of 517 subjects, and all selected studies reported the mean ADC value (10(-3) mm(2)/s) in DWI in cervical cancer patients treated with RT and CT. Combined standardized mean difference (SMD) suggested that the mean post-RT and mean post-CT ADC values were significantly higher than the mean pre-RT and mean pre-CT ADC values, respectively, in cervical cancer patients (SMD=2.95, 95% CI=2.19-3.72, P<0.001). Ethnicity-stratified analysis revealed that increased ADC values were observed post-RT and post-CT in both Caucasian (SMD=1.44, 95% CI=0.93-1.95, P<0.001) and Asian populations (SMD=3.32, 95% CI=2.42-4.22, P<0.001), compared with the mean ADC values before RT and CT, respectively, in the two subgroups. Further, subgroup analysis based on b-value revealed that higher ADC values were found in cervical cancer patients after RT and CT, compared to before RT and CT treatment, with both b value≤900 (SMD=3.71, 95% CI=2.35-5.07, P<0.001) and >900 (SMD=2.55, 95% CI=1.78-3.32, P<0.001). The mean ADC value in patients without residual tumor post-RT and post-CT treatment was significantly higher than seen in patients with residual tumors (SMD=0.80, 95% CI=0.49-1.12, P<0.001). Our meta-analysis revealed a significant correlation between mean ADC values and the clinical response to RT and CT treatment. Thus, ADC values in DWI may be effective in evaluating the clinical outcome of treatments in cervical cancer patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Gottlieb, Josh; Princenthal, Robert; Cohen, Martin I
2017-07-01
To evaluate the multi-parametric MRI (mpMRI) findings in patients with biopsy-proven granulomatous prostatitis and prior Bacillus Calmette-Guérin (BCG) exposure. MRI was performed in six patients with pathologically proven granulomatous prostatitis and a prior history of bladder cancer treated with intravesical BCG therapy. Multi-parametric prostate MRI images were recorded on a GE 750W or Philips Achieva 3.0 Tesla MRI scanner with high-resolution, small-field-of-view imaging consisting of axial T2, axial T1, coronal T2, sagittal T2, axial multiple b-value diffusion (multiple values up to 1200 or 1400), and dynamic contrast-enhanced 3D axial T1 with fat suppression sequence. Two different patterns of MR findings were observed. Five of the six patients had a low mean ADC value <1000 (decreased signal on ADC map images) and isointense signal on high-b-value imaging (b = 1200 or 1400), consistent with nonspecific granulomatous prostatitis. The other pattern seen in one of the six patients was decreased signal on the ADC map images with increased signal on the high-b-value sequence, revealing true restricted diffusion indistinguishable from aggressive prostate cancer. This patient had biopsy-confirmed acute BCG prostatitis. Our study suggests that patients with known BCG exposure and PI-RADS v2 scores ≤3, showing similar mpMRI findings as demonstrated, may not require prostate biopsy.
Vidić, Igor; Egnell, Liv; Jerome, Neil P; Teruel, Jose R; Sjøbakk, Torill E; Østlie, Agnes; Fjøsne, Hans E; Bathen, Tone F; Goa, Pål Erik
2018-05-01
Diffusion-weighted MRI (DWI) is currently one of the fastest developing MRI-based techniques in oncology. Histogram properties from model fitting of DWI are useful features for differentiation of lesions, and classification can potentially be improved by machine learning. To evaluate classification of malignant and benign tumors and breast cancer subtypes using support vector machine (SVM). Prospective. Fifty-one patients with benign (n = 23) and malignant (n = 28) breast tumors (26 ER+, whereof six were HER2+). Patients were imaged with DW-MRI (3T) using twice refocused spin-echo echo-planar imaging with echo time / repetition time (TR/TE) = 9000/86 msec, 90 × 90 matrix size, 2 × 2 mm in-plane resolution, 2.5 mm slice thickness, and 13 b-values. Apparent diffusion coefficient (ADC), relative enhanced diffusivity (RED), and the intravoxel incoherent motion (IVIM) parameters diffusivity (D), pseudo-diffusivity (D*), and perfusion fraction (f) were calculated. The histogram properties (median, mean, standard deviation, skewness, kurtosis) were used as features in SVM (10-fold cross-validation) for differentiation of lesions and subtyping. Accuracies of the SVM classifications were calculated to find the combination of features with highest prediction accuracy. Mann-Whitney tests were performed for univariate comparisons. For benign versus malignant tumors, univariate analysis found 11 histogram properties to be significant differentiators. Using SVM, the highest accuracy (0.96) was achieved from a single feature (mean of RED), or from three feature combinations of IVIM or ADC. Combining features from all models gave perfect classification. No single feature predicted HER2 status of ER + tumors (univariate or SVM), although high accuracy (0.90) was achieved with SVM combining several features. Importantly, these features had to include higher-order statistics (kurtosis and skewness), indicating the importance to account for heterogeneity. Our findings suggest that SVM, using features from a combination of diffusion models, improves prediction accuracy for differentiation of benign versus malignant breast tumors, and may further assist in subtyping of breast cancer. 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1205-1216. © 2017 International Society for Magnetic Resonance in Medicine.
Deng, Yu; Li, Xinchun; Lei, Yongxia; Liang, Changhong; Liu, Zaiyi
2016-11-01
Background Using imaging techniques to diagnose malignant and inflammatory lesions in the lung can be challenging. Purpose To compare intravoxel incoherent motion (IVIM) and apparent diffusion coefficient (ADC) magnetic resonance imaging (MRI) analysis in their ability to discriminate lung cancer from focal inflammatory lung lesions. Material and Methods Thirty-eight patients with lung masses were included: 30 lung cancers and eight inflammatory lesions. Patients were imaged with 3.0T MRI diffusion weighted imaging (DWI) using 10 b values (range, 0-1000 s/mm 2 ). Tissue diffusivity ( D), pseudo-diffusion coefficient ( D*), and perfusion fraction ( f) were calculated using segmented biexponential analysis. ADC (total) was calculated with monoexponential fitting of the DWI data. D, D*, f, and ADC were compared between lung cancer and inflammatory lung lesions. Receiver operating characteristic analysis was performed for all DWI parameters. Results The ADC was significantly higher for inflammatory lesions than for lung cancer ([1.21 ± 0.20] × 10 -3 mm 2 /s vs. [0.97 ± 0.15] × 10 -3 mm 2 /s; P = 0.004). By IVIM, f was found to be significantly higher in inflammatory lesions than lung cancer ([46.10 ± 12.92] % vs. [29.29 ± 10.89] %; P = 0.005). There was no difference in D and D* between lung cancer and inflammatory lesions ( P = 0.747 and 0.124, respectively). f showed comparable diagnostic performance with ADC in differentiating lung cancer from inflammatory lung lesions, with areas under the curve of 0.833 and 0.826, sensitivity 80.0% and 73.3%, and specificity 75.0% and 87.5%, respectively. Conclusion The IVIM parameter f value provides comparable diagnostic performance with ADC and could be used as a surrogate marker for differentiating lung cancer from inflammatory lesions.
Abdel Razek, Ahmed Abdel Khalek; El-Said, Amr Abd El-hamid
2017-01-01
Summary Background To assess the role of diffusion-weighted MR imaging in differentiation between Graves’ disease and painless thyroiditis. Material/Methods A prospective study was conducted among 37 consecutive patients with untreated thyrotoxicosis (25 female and 12 male; mean age of 44 years) and 15 ageand sex-matched controls. Diffusion-weighted MR imaging of the thyroid gland was performed in patients and controls. The apparent diffusion coefficient (ADC) value of the thyroid gland was calculated and correlated with Tc-99m uptake and thyroid function tests of the patients. Results There was a significant difference in the ADC value of the thyroid gland between patients and the control group (P=0.001). The mean ADC value of the thyroid gland in Graves’ disease was 2.03±0.28×10–3 mm2/sec, and in patients with painless thyroiditis 1.46±0.22×10–3 mm2/sec, respectively. There was a significant difference in the ADC values between Graves’ disease and painless thyroiditis (P=0.001). When the ADC value of 1.45×10–3 mm2/sec was used as a threshold value for differentiating Graves’ disease from painless thyroiditis, the best result was obtained with area under the curve of 0.934, accuracy of 83.8%, sensitivity of 95.8%, and specificity of 61.5%. The mean ADC value of the thyroid gland in patients positively correlated with serum TRAb and Tc-99m uptake (r=0.57, P=0.001 and r=0.74, P=0.001, respectively). Conclusions We concluded that ADC values of the thyroid gland can be used to differentiate Graves’ disease from painless thyroiditis in patients with untreated thyrotoxicosis. PMID:29662585
Abdel Razek, Ahmed Abdel Khalek; Abd Allah, Sieza Samir; El-Said, Amr Abd El-Hamid
2017-01-01
To assess the role of diffusion-weighted MR imaging in differentiation between Graves' disease and painless thyroiditis. A prospective study was conducted among 37 consecutive patients with untreated thyrotoxicosis (25 female and 12 male; mean age of 44 years) and 15 ageand sex-matched controls. Diffusion-weighted MR imaging of the thyroid gland was performed in patients and controls. The apparent diffusion coefficient (ADC) value of the thyroid gland was calculated and correlated with Tc-99m uptake and thyroid function tests of the patients. There was a significant difference in the ADC value of the thyroid gland between patients and the control group ( P =0.001). The mean ADC value of the thyroid gland in Graves' disease was 2.03±0.28×10 -3 mm 2 /sec, and in patients with painless thyroiditis 1.46±0.22×10 -3 mm 2 /sec, respectively. There was a significant difference in the ADC values between Graves' disease and painless thyroiditis ( P =0.001). When the ADC value of 1.45×10 -3 mm 2 /sec was used as a threshold value for differentiating Graves' disease from painless thyroiditis, the best result was obtained with area under the curve of 0.934, accuracy of 83.8%, sensitivity of 95.8%, and specificity of 61.5%. The mean ADC value of the thyroid gland in patients positively correlated with serum TRAb and Tc-99m uptake ( r =0.57, P =0.001 and r =0.74, P =0.001, respectively). We concluded that ADC values of the thyroid gland can be used to differentiate Graves' disease from painless thyroiditis in patients with untreated thyrotoxicosis.
Liu, Wei; Liu, Xiao H; Tang, Wei; Gao, Hong B; Zhou, Bing N; Zhou, Liang P
2018-02-07
Noninvasive measures to evaluate the aggressiveness of prostate carcinoma (PCa) may benefit patients. To assess the value of stretched-exponential and monoexponential diffusion-weighted imaging (DWI) for predicting the aggressiveness of PCa. Retrospective study. Seventy-five patients with PCa. 3T DWI examinations were performed using b-values of 0, 500, 1000, and 2000 s/mm 2 . The research were based on entire-tumor histogram analysis and the reference standard was radical prostectomy. The correlation analysis was programmed with Spearman's rank-order analysis between the histogram variables and Gleason grade group (GG). Receiver operating characteristic (ROC) regression was used to analyze the ability of these histogram variables to differentiate low-grade (LG) from intermediate/high-grade (HG) PCa. The percentiles and mean of apparent diffusion coefficient (ADC) and distributed diffusion coefficient (DDC) were correlated with GG (ρ: 0.414-0.593), while there was no significant relation among α value, skewnesses, and kurtosises with GG (ρ:0.034-0.323). HG tumors (ADC:484 ± 136, 592 ± 139, 670 ± 144, 788 ± 146, 895 ± 141 mm 2 /s; DDC: 410 ± 142, 532 ± 172, 666 ± 193, 786 ± 196, 914 ± 181 mm 2 /s) had lower values in the 10 th , 25 th , 50 th , 75 th percentiles and means than LG tumors (ADC: 644 ± 779, 737 ± 84, 836 ± 83, 919 ± 82, 997 ± 107 mm 2 /s; DDC: 552 ± 82, 680 ± 94, 829 ± 112, 931 ± 106, 1045 ± 100 mm 2 /s). However, there was no difference between LG and HG tumors in α value (0.671 ± 0.041 vs. 0.633 ± 0.114), kurtosises (ADC 0.09 vs. 0.086; DDC -0.033 vs. -0.317), or skewnesses (ADC -0.036 vs. 0.073; DDC -0.063 vs. 0.136). The above statistics were P < 0.01. ADC10 with AUC = 0.840 and DDC10 with AUC = 0.799 were similar in discriminating between LG and HG PCa at P < 0.05. Histogram variables of DDC and ADC may predict the aggressiveness of PCa, while α value does not. The abilities of ADC10 and DDC10 to discriminate LG from HG tumors were similar, and both better than their respective means. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Metallic diffusion measured by a modified Knudsen technique
NASA Technical Reports Server (NTRS)
Fray, D. J.
1969-01-01
Diffusion coefficient of a metal in high temperature system is determined. From the measurement of the weight loss from a Knudsen cell, the vapor pressure of the escaping species can be calculated. If the only way this species can enter the Knudsen cell is by diffusion through a foil, the weight loss is diffusion flux.
NASA Astrophysics Data System (ADS)
Wang, Y.; Ahn, J.; Kim, D.; Ren, W. J.; Liu, W.; Zhang, Z. D.; Choi, C. J.
2017-10-01
Nd-Fe-B nanoparticles with a particle size below 50 nm and excellent magnetic properties were obtained via a novel route which makes use of both spray drying and reduction-diffusion processes. Uniform Nd-Fe-B particles were formed by the optimization of Ca amount as a reducing agent and additional washing by milling in ethanol media. Especially, we implemented a two-step washing process which contributed to the excellent magnetic properties with high remanence and coercivity. After the removal of CaO by novel washing process, the maximum energy product (BH)max of the particles showed 22.1 MGOe. This value is superior to those reported in reduction-diffusion process. We used Henkel plot to assume the mechanism of magnetic interactions of the Nd-Fe-B nanoparticles.
Ichikawa, Shintaro; Motosugi, Utaroh; Hernando, Diego; Morisaka, Hiroyuki; Enomoto, Nobuyuki; Matsuda, Masanori; Onishi, Hiroshi
2018-04-10
To compare the abilities of three intravoxel incoherent motion (IVIM) imaging approximation methods to discriminate the histological grade of hepatocellular carcinomas (HCCs). Fifty-eight patients (60 HCCs) underwent IVIM imaging with 11 b-values (0-1000 s/mm 2 ). Slow (D) and fast diffusion coefficients (D * ) and the perfusion fraction (f) were calculated for the HCCs using the mean signal intensities in regions of interest drawn by two radiologists. Three approximation methods were used. First, all three parameters were obtained simultaneously using non-linear fitting (method A). Second, D was obtained using linear fitting (b = 500 and 1000), followed by non-linear fitting for D * and f (method B). Third, D was obtained by linear fitting, f was obtained using the regression line intersection and signals at b = 0, and non-linear fitting was used for D * (method C). A receiver operating characteristic analysis was performed to reveal the abilities of these methods to distinguish poorly-differentiated from well-to-moderately-differentiated HCCs. Inter-reader agreements were assessed using intraclass correlation coefficients (ICCs). The measurements of D, D * , and f in methods B and C (Az-value, 0.658-0.881) had better discrimination abilities than did those in method A (Az-value, 0.527-0.607). The ICCs of D and f were good to excellent (0.639-0.835) with all methods. The ICCs of D * were moderate with methods B (0.580) and C (0.463) and good with method A (0.705). The IVIM parameters may vary depending on the fitting methods, and therefore, further technical refinement may be needed.
Dynamic and Inherent B0 Correction for DTI Using Stimulated Echo Spiral Imaging
Avram, Alexandru V.; Guidon, Arnaud; Truong, Trong-Kha; Liu, Chunlei; Song, Allen W.
2013-01-01
Purpose To present a novel technique for high-resolution stimulated echo (STE) diffusion tensor imaging (DTI) with self-navigated interleaved spirals (SNAILS) readout trajectories that can inherently and dynamically correct for image artifacts due to spatial and temporal variations in the static magnetic field (B0) resulting from eddy currents, tissue susceptibilities, subject/physiological motion, and hardware instabilities. Methods The Hahn spin echo formed by the first two 90° radio-frequency pulses is balanced to consecutively acquire two additional images with different echo times (TE) and generate an inherent field map, while the diffusion-prepared STE signal remains unaffected. For every diffusion-encoding direction, an intrinsically registered field map is estimated dynamically and used to effectively and inherently correct for off-resonance artifacts in the reconstruction of the corresponding diffusion-weighted image (DWI). Results After correction with the dynamically acquired field maps, local blurring artifacts are specifically removed from individual STE DWIs and the estimated diffusion tensors have significantly improved spatial accuracy and larger fractional anisotropy. Conclusion Combined with the SNAILS acquisition scheme, our new method provides an integrated high-resolution short-TE DTI solution with inherent and dynamic correction for both motion-induced phase errors and off-resonance effects. PMID:23630029
Ream, Justin M; Dillman, Jonathan R; Adler, Jeremy; Khalatbari, Shokoufeh; McHugh, Jonathan B; Strouse, Peter J; Dhanani, Muhammad; Shpeen, Benjamin; Al-Hawary, Mahmoud M
2013-09-01
Restricted diffusion on diffusion-weighted imaging (DWI) sequences during magnetic resonance enterography (MRE) has been shown in segments of bowel affected by Crohn disease. However, the exact meaning of this finding, particularly within the pediatric Crohn disease population, is poorly understood. The purpose of this study was to determine the significance of bowel wall restricted diffusion in children with small bowel Crohn disease by correlating apparent diffusion coefficient (ADC) values with other MRI markers of disease activity. A retrospective review of pediatric patients (≤ 18 years of age) with Crohn disease terminal ileitis who underwent MRE with DWI at our institution between May 1, 2009 and May 31, 2011 was undertaken. All of the children had either biopsy-proven Crohn disease terminal ileitis or clinically diagnosed Crohn disease, including terminal ileal involvement by imaging. The mean minimum ADC value within the wall of the terminal ileum was determined for each examination. ADC values were tested for correlation/association with other MRI findings to determine whether a relationship exists between bowel wall restricted diffusion and disease activity. Forty-six MRE examinations with DWI in children with terminal ileitis were identified (23 girls and 23 boys; mean age, 14.3 years). There was significant negative correlation or association between bowel wall minimum ADC value and established MRI markers of disease activity, including degree of bowel wall thickening (R = (-)0.43; P = 0.003), striated pattern of arterial enhancement (P = 0.01), degree of arterial enhancement (P = 0.01), degree of delayed enhancement (P = 0.045), amount of mesenteric inflammatory changes (P < 0.0001) and presence of a stricture (P = 0.02). ADC values were not significantly associated with bowel wall T2-weighted signal intensity, length of disease involvement or mesenteric fibrofatty proliferation. Increasing bowel wall restricted diffusion (lower ADC values) is associated with multiple MRI findings that are traditionally associated with active inflammation in pediatric small bowel Crohn disease.
Xu, Dan; Maier, Joseph K; King, Kevin F; Collick, Bruce D; Wu, Gaohong; Peters, Robert D; Hinks, R Scott
2013-11-01
The proposed method is aimed at reducing eddy current (EC) induced distortion in diffusion weighted echo planar imaging, without the need to perform further image coregistration between diffusion weighted and T2 images. These ECs typically have significant high order spatial components that cannot be compensated by preemphasis. High order ECs are first calibrated at the system level in a protocol independent fashion. The resulting amplitudes and time constants of high order ECs can then be used to calculate imaging protocol specific corrections. A combined prospective and retrospective approach is proposed to apply correction during data acquisition and image reconstruction. Various phantom, brain, body, and whole body diffusion weighted images with and without the proposed method are acquired. Significantly reduced image distortion and misregistration are consistently seen in images with the proposed method compared with images without. The proposed method is a powerful (e.g., effective at 48 cm field of view and 30 cm slice coverage) and flexible (e.g., compatible with other image enhancements and arbitrary scan plane) technique to correct high order ECs induced distortion and misregistration for various diffusion weighted echo planar imaging applications, without the need for further image post processing, protocol dependent prescan, or sacrifice in signal-to-noise ratio. Copyright © 2013 Wiley Periodicals, Inc.
Skorpil, M; Brynolfsson, P; Engström, M
2017-06-01
Multiparametric magnetic resonance imaging (MRI) and PI-RADS (Prostate Imaging - Reporting and Data System) has become the standard to determine a probability score for a lesion being a clinically significant prostate cancer. T2-weighted and diffusion-weighted imaging (DWI) are essential in PI-RADS, depending partly on visual assessment of signal intensity, while dynamic-contrast enhanced imaging is less important. To decrease inter-rater variability and further standardize image evaluation, complementary objective measures are in need. We here demonstrate a sequence enabling simultaneous quantification of apparent diffusion coefficient (ADC) and T2-relaxation, as well as calculation of the perfusion fraction f from low b-value intravoxel incoherent motion data. Expandable wait pulses were added to a FOCUS DW SE-EPI sequence, allowing the effective echo time to change at run time. To calculate both ADC and f, b-values 200s/mm 2 and 600s/mm 2 were chosen, and for T2-estimation 6 echo times between 64.9ms and 114.9ms were used. Three patients with prostate cancer were examined and all had significantly decreased ADC and T2-values, while f was significantly increased in 2 of 3 tumors. T2 maps obtained in phantom measurements and in a healthy volunteer were compared to T2 maps from a SE sequence with consecutive scans, showing good agreement. In addition, a motion correction procedure was implemented to reduce the effects of prostate motion, which improved T2-estimation. This sequence could potentially enable more objective tumor grading, and decrease the inter-rater variability in the PI-RADS classification. Copyright © 2017 Elsevier Inc. All rights reserved.
Ozel, Betul Duran; Ozel, Deniz; Ozkan, Fuat; Halefoglu, Ahmet M
2016-03-01
The aim of this prospective study was to evaluate the value of diffusion-weighted magnetic resonance imaging (DW-MRI) in patients with osteonecrosis. Patients were divided into two subgroups as avascular necrosis (AVN) of femoral head for adult group and Legg-Calvé-Perthes (LCP) patients for children. Seventeen patients with femoral head AVN (mean age 42.3 years) and 17 patients with LCP (mean age 8.2 years) were included in this study. Diagnosis confirmed with clinical and other imaging procedures among the patients complaining hip pain. DW images were obtained using the single-shot echo planar sequence and had b values of 0, 500, 1000 s/mm(2). The apparent diffusion coefficient (ADC) values were measured from ADC maps in epiphysis of patients with AVN, both from metaphysis and epiphysis in patients with LCP, respectively. Mann-Whitney U test was used to compare ADC values. The mean ADC value of femoral heads (1.285 ± 0.204 × 10(-3) mm(2)/s) was increased in patients with AVN when compared to normal bone tissue (0.209 ± 0.214 × 10(-3) mm(2)/s) (p < 0.01). The mean ADC values (×10(-3) mm(2)/s) of both metaphysis (0.852 ± 0.293) and epiphysis (0.843 ± 0.332) were also increased in patients with LCP and differences were statistically significant (p < 0.01). As a result, osteonecrosis shows increased ADC values. But it is a controversial concept that DWI offers a valuable data to conventional MRI or not. However, as there are report states, there is a correlation between the stage of the disease with ADC values in the LCP disease. DWI is a fast, without-contrast administration technique and provides quantitative values additional to conventional MR techniques; we believe DWI may play an additional assistance to the diagnosis and treatment for LCP patients. Multicentric larger group studies may provide additional data to this issue.
Ward, Phil; Counsell, Serena; Allsop, Joanna; Cowan, Frances; Shen, Yuji; Edwards, David; Rutherford, Mary
2006-04-01
Apparent diffusion coefficients (ADC) that are measured by diffusion-weighted imaging are reduced in severe white matter (WM) and in some severe basal ganglia and thalamic (BGT) injury in infants who present with hypoxic-ischemic encephalopathy (HIE). However, ADC values may pseudonormalize or even be high during this time in some less severe but clinically significant injuries. We hypothesized that fractional anisotropy (FA), a measure of the directional diffusivity of water made using diffusion tensor imaging, may be abnormal in these less severe injuries; therefore, the objective of this study was to use diffusion tensor imaging to measure ADC and FA in infants with moderate and severe hypoxic-ischemic brain injury. Twenty infants with HIE and 7 normal control infants were studied. All infants were born at >36 weeks' gestational age, and MRI scans were obtained within 3 weeks of delivery. Data were examined for normality, and comparisons were made using analysis of variance or Kruskal-Wallis as appropriate. During the first week, FA values were decreased with both severe and moderate WM and BGT injury as assessed by conventional imaging, whereas ADC values were reduced only in severe WM injury and some severe BGT injury. Abnormal ADC values pseudonormalized during the second week, whereas FA values continued to decrease. FA is reduced in moderate brain injury after HIE. A low FA may reflect a breakdown in WM organization. Moderate BGT injury may result in atrophy but not overt infarction; it is possible that delayed apoptosis is more marked than immediate necrosis, and this may account for normal early ADC values. The accompanying low FA within some severe and all moderate gray matter lesions, which is associated with significant later impairment, may help to confirm clinically significant abnormality in infants with normal ADC values.
Tsili, Athina C; Ntorkou, Alexandra; Astrakas, Loukas; Xydis, Vasilis; Tsampalas, Stavros; Sofikitis, Nikolaos; Argyropoulou, Maria I
2017-04-01
To evaluate the difference in apparent diffusion coefficient (ADC) measurements at diffusion-weighted (DW) magnetic resonance imaging of differently shaped regions-of-interest (ROIs) in testicular germ cell neoplasms (TGCNS), the diagnostic ability of differently shaped ROIs in differentiating seminomas from nonseminomatous germ cell neoplasms (NSGCNs) and the interobserver variability. Thirty-three TGCNs were retrospectively evaluated. Patients underwent MR examinations, including DWI on a 1.5-T MR system. Two observers measured mean tumor ADCs using four distinct ROI methods: round, square, freehand and multiple small, round ROIs. The interclass correlation coefficient was analyzed to assess interobserver variability. Statistical analysis was used to compare mean ADC measurements among observers, methods and histologic types. All ROI methods showed excellent interobserver agreement, with excellent correlation (P<0.001). Multiple, small ROIs provided the lower mean ADC in TGCNs. Seminomas had lower mean ADC compared to NSGCNs for each ROI method (P<0.001). Round ROI proved the most accurate method in characterizing TGCNS. Interobserver variability in ADC measurement is excellent, irrespective of the ROI shape. Multiple, small round ROIs and round ROI proved the more accurate methods for ADC measurement in the characterization of TGCNs and in the differentiation between seminomas and NSGCNs, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Chavhan, Govind B; Alsabban, Zehour; Babyn, Paul S
2014-01-01
Diffusion-weighted (DW) imaging is an emerging technique in body imaging that provides indirect information about the microenvironment of tissues and lesions and helps detect, characterize, and follow up abnormalities. Two main challenges in the application of DW imaging to body imaging are the decreased signal-to-noise ratio of body tissues compared with neuronal tissues due to their shorter T2 relaxation time, and image degradation related to physiologic motion (eg, respiratory motion). Use of smaller b values and newer motion compensation techniques allow the evaluation of anatomic structures with DW imaging. DW imaging can be performed as a breath-hold sequence or a free-breathing sequence with or without respiratory triggering. Depending on the mobility of water molecules in their microenvironment, different normal tissues have different signals at DW imaging. Some normal tissues (eg, lymph nodes, spleen, ovarian and testicular parenchyma) are diffusion restricted, whereas others (eg, gallbladder, corpora cavernosa, endometrium, cartilage) show T2 shine-through. Epiphyses that contain fatty marrow and bone cortex appear dark on both DW images and apparent diffusion coefficient maps. Current and emerging applications of DW imaging in pediatric body imaging include tumor detection and characterization, assessment of therapy response and monitoring of tumors, noninvasive detection and grading of liver fibrosis and cirrhosis, detection of abscesses, and evaluation of inflammatory bowel disease. RSNA, 2014
Application of diffusion kurtosis imaging to odontogenic lesions: Analysis of the cystic component.
Sakamoto, Junichiro; Kuribayashi, Ami; Kotaki, Shinya; Fujikura, Mamiko; Nakamura, Shin; Kurabayashi, Tohru
2016-12-01
To assess the feasibility of applying diffusion kurtosis imaging (DKI) to common odontogenic lesions and to compare its diagnostic ability versus that of the apparent diffusion coefficient (ADC) for differentiating keratocystic odontogenic tumors (KCOTs) from odontogenic cysts. Altogether, 35 odontogenic lesions were studied: 24 odontogenic cysts, six KCOTs, and five ameloblastomas. The diffusion coefficient (D) and excessive kurtosis (K) were obtained from diffusion-weighted images at b-values of 0, 500, 1000, and 1500 s/mm 2 on 3T magnetic resonance imaging (MRI). The combination of D and K values showing the maximum density of the probable density function was estimated. The ADC was obtained (0 and 1000 s/mm 2 ). Values for odontogenic cysts, KCOTs, and ameloblastomas were compared. Multivariate logistic regression modeling was performed to assess the combination of D and K model versus ADC for differentiating KCOTs from odontogenic cysts. The mean D and ADC were significantly higher for ameloblastomas than for odontogenic cysts or KCOTs (P < 0.05). The mean K was significantly lower for ameloblastomas than for odontogenic cysts or KCOTs (P < 0.05). The mean values of all parameters for odontogenic cysts and KCOTs showed no significant differences (P = 0.369 for ADC, 0.133 for D, and 0.874 for K). The accuracy of the combination of D and K model (76.7%) was superior to that of ADC (66.7%). Use of DKI may be feasible for common odontogenic lesions. A combination of DKI parameters can be expected to increase the accuracy of its diagnostic ability compared with ADC. J. Magn. Reson. Imaging 2016;44:1565-1571. © 2016 International Society for Magnetic Resonance in Medicine.
Serrano, E; Ocantos, J; Kohan, A; Kisilevsky, N; Napoli, N; García-Mónaco, R
2016-01-01
To analyze the usefulness of diffusion magnetic resonance (MR) sequences before and after prostatic artery embolization (PAE) in patients with benign prostatic hyperplasia (BPH). We analyzed MR studies done before (7-10 days) and after (30 days) PAE in 19 patients with BPH treated with PAE between June 2012 and December 2013. We used 1.5 Tesla scanners with body surface coils. In pre-PAE MR studies, we recorded mean b40 values and minimum (min) and maximum (max) apparent diffusion coefficient (ADC) values. In post-PAE MR studies, we recorded b40, b400, and b1000 values and min, mean, and max ADC values. We compared diffusion behavior/ADC before and after PAE and areas without ischemia. We correlated these with decreased prostatic volume (PV). We identified ischemia with contrast in 8 (42.1%) patients. No significant difference was found in mean b40 (p= 0.1650) or in the b40 ratio (p= 0.8868) between patients with ischemia and those without before PAE. Min b40, b40 ratio, and min ADC values differed significantly between ischemic areas and nonischemic areas within patients [p= 0.048 (b40min and ratio) and p= 0.002 (min ADC)]. No significant correlation was found between the percentage decrease in PV and mean b40 (p= 0.8490) or b40 ratio (p=0.8573). Post-PAE ischemia generates objective changes in diffusion and ADC values that enable ischemic sectors to be differentiated from nonischemic sectors. Future studies should analyze whether it is possible to subjectively differentiate between these areas through the visualization of nonischemic sectors and the feasibility of replacing them with contrast to detect ischemia. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
MO-F-CAMPUS-I-05: Quantitative ADC Measurement of Esophageal Cancer Before and After Chemoradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, L; UT MD Anderson Cancer Center, Houston, TX; Son, JB
2015-06-15
Purpose: We investigated whether quantitative diffusion imaging can be used as an imaging biomarker for early prediction of treatment response of esophageal cancer. Methods: Eight patients with esophageal cancer underwent a baseline and an interim MRI studies during chemoradiation on a 3T whole body MRI scanner with an 8-channel torso phased array coil. Each MRI study contained two axial diffusion-weighted imaging (DWI) series with a conventional DWI sequence and a reduced field-of-view DWI sequence (FOCUS) of varying b-values. ADC maps with two b-values were computed from conventional DWI images using a mono-exponential model. For each of DWI sequences, separate ADCallmore » was computed by fitting the signal intensity of images with all the b-values to a single exponential model. For the FOCUS sequence, a bi-exponential model was used to extract perfusion and diffusion coefficients (ADCperf and ADCdiff) and their contributions to the signal decay. A board-certified radiologist contoured the tumor region and mean ADC values and standard deviations of tumor and muscle ROIs were recorded from different ADC maps. Results: Our results showed that (1) the magnitude of ADCs from the same ROIs by the different analysis methods can be substantially different. (2) For a given method, the change between the baseline and interim muscle ADCs was relatively small (≤10%). In contrast, the change between the baseline and interim tumor ADCs was substantially larger, with the change in ADCdiff by FOCUS DWI showing the largest percentage change of 73.2%. (3) The range of the relative change of a specific parameter for different patients was also different. Conclusion: Presently, we do not have the final pathological confirmation of the treatment response for all the patients. However, for a few patients whose surgical specimen is available, the quantitative ADC changes have been found to be useful as a potential predictor for treatment response.« less
Zheng, De-Xian; Meng, Shu-Chun; Liu, Qing-Jun; Li, Chuan-Ting; Shang, Xi-Dan; Zhu, Yu-Seng; Bai, Tian-Jun; Xu, Shi-Ming
2016-01-01
AIM: To determine if efficacy of chemotherapy on liver metastasis of gastrointestinal tract cancer can be predicted by apparent diffusion coefficient (ADC) values of diffusion-weighted imaging (DWI). METHODS: In total, 86 patients with liver metastasis of gastrointestinal tract cancer (156 metastatic lesions) diagnosed in our hospital were included in this study. The maximum diameters of these tumors were compared with each other before treatment, 2 wk after treatment, and 12 wk after treatment. Selected patients were classified as the effective group and the ineffective group, depending on the maximum diameter of the tumor after 12 wk of treatment; and the ADC values at different treatment times between the two groups were compared. Spearman rank correlation was used to analyze the relationship between ADC value and tumor diameter. Receiver operating characteristic curve (ROC curve) was used to analyze the ADC values before treatment to predict the patient’s sensitivity and specificity degree of efficacy to the chemotherapy. RESULTS: There was no difference in age between the two groups and in maximum tumor diameter before treatment and 2 wk after treatment. However, after 12 wk of treatment, maximum tumor diameter in the effective group was significantly lower than that in the ineffective group (P < 0.05). Before treatment, ADC values in the ineffective group were significantly higher than those in the effective group (P < 0.05). There was no difference in ADC values between the effective and ineffective groups after 2 and 12 wk of treatment. However, ADC values were significantly higher after 2 and 12 wk of treatment compared to before treatment in the effective group (P < 0.05). Spearman rank correlation analysis showed that ADC value before treatment and the reduced percentage of the maximum tumor diameter after 12 wk of treatment were negatively correlated, while the increase in the percentage of the ADC value 12 wk after treatment and the decrease in the percentage of the maximum tumor diameter were significantly positively correlated. The results of the ROC curve showed that ADC value with a chemotherapy ineffective threshold value of 1.14 × 10-3 mm2/s before treatment had a sensitivity and specificity of 94.3% and 76.7%, respectively. CONCLUSION: DWI ADC values can be used to predict the response of patients with liver metastasis of gastrointestinal tract cancer to chemotherapy with high sensitivity and relatively high specificity. PMID:26973399
Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects.
Cutajar, Marica; Clayden, Jonathan D; Clark, Christopher A; Gordon, Isky
2011-12-01
This study assessed test-retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Seven healthy volunteers (age range, 19-31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR=730 ms, TE=73 ms and 2 b-values (0 and 400 s mm(-2)). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Shkilnyy, Andriy; Proulx, Pierre; Sharp, Jamie; Lepage, Martin; Vermette, Patrick
2012-05-01
Scaffolds with adequate mass transport properties are needed in many tissue engineering applications. Fibrin is considered a good biological material to fabricate such scaffolds. However, very little is known about mass transport in fibrin. Therefore, a method based on the analysis of fluorescence intensity for measuring the apparent diffusion coefficient of rhodamine B and fluorescein-labelled bovine serum albumin (FITC-BSA) is described. The experiments are performed in fibrin gels with and without human umbilical vein endothelial cells (HUVEC). The apparent diffusion coefficients of rhodamine B and FITC-BSA in fibrin (fibrinogen concentration of 4 mg/mL) with different cell densities are reported. A LIVE/DEAD(®) assay is performed to confirm the viability of HUVEC seeded at high densities. Diffusion coefficients for rhodamine B remain more or less constant up to 5×10(5) cells/mL and correlate well with literature values measured by other methods in water systems. This indicates that the presence of HUVEC in the fibrin gels (up to 5×10(5) cells/mL) has almost no effect on the diffusion coefficients. Higher cell densities (>5×10(5) cells/mL) result in a decrease of the diffusion coefficients. Diffusion coefficients of rhodamine B and FITC-BSA obtained by this method agree with diffusion coefficients in water predicted by the Stokes-Einstein equation. The experimental design used in this study can be applied to measure diffusion coefficients in different types of gels seeded or not with living cells. Copyright © 2012 Elsevier B.V. All rights reserved.
Li, Cun-Yu; Wu, Xin; Gu, Jia-Mei; Li, Hong-Yang; Peng, Guo-Ping
2018-04-01
Based on the molecular sieving and solution-diffusion effect in nanofiltration separation, the correlation between initial concentration and mass transfer coefficient of three typical phenolic acids from Salvia miltiorrhiza was fitted to analyze the relationship among mass transfer coefficient, molecular weight and concentration. The experiment showed a linear relationship between operation pressure and membrane flux. Meanwhile, the membrane flux was gradually decayed with the increase of solute concentration. On the basis of the molecular sieving and solution-diffusion effect, the mass transfer coefficient and initial concentration of three phenolic acids showed a power function relationship, and the regression coefficients were all greater than 0.9. The mass transfer coefficient and molecular weight of three phenolic acids were negatively correlated with each other, and the order from high to low is protocatechualdehyde >rosmarinic acid> salvianolic acid B. The separation mechanism of nanofiltration for phenolic acids was further clarified through the analysis of the correlation of molecular weight and nanofiltration mass transfer coefficient. The findings provide references for nanofiltration separation, especially for traditional Chinese medicine with phenolic acids. Copyright© by the Chinese Pharmaceutical Association.
Sarkozy, Clémentine; Camus, Vincent; Tilly, Hervé; Salles, Gilles; Jardin, Fabrice
2015-07-01
Diffuse large B-cell lymphoma (DLBCL) is the most common form of aggressive non-Hodgkin lymphoma, accounting for 30-40% of newly diagnosed cases. Obesity is a well-defined risk factor for DLBCL. However, the impact of body mass index (BMI) on DLBCL prognosis is controversial. Recent studies suggest that skeletal muscle wasting (sarcopenia) or loss of fat mass can be detected by computed tomography (CT) images and is useful for predicting the clinical outcome in several types of cancer including DLBCL. Several hypotheses have been proposed to explain the differences in DLBCL outcome according to BMI or weight that include tolerance to treatment, inflammatory background and chemotherapy or rituximab metabolism. In this review, we summarize the available literature, addressing the impact and physiopathological relevance of simple anthropometric tools including BMI and tissue distribution measurements. We also discuss their relationship with other nutritional parameters and their potential role in the management of patients with DLBCL.
Diffusion Weighted MRI and MRS to Differentiate Radiation Necrosis and Recurrent Disease in Gliomas
NASA Astrophysics Data System (ADS)
Ewell, Lars
2006-03-01
A difficulty encountered in the diagnosis of patients with gliomas is the differentiation between recurrent disease and Radiation Induced Necrosis (RIN). Both can appear as ‘enhancing lesions’ on a typical T2 weighted MRI scan. Magnetic Resonance Spectroscopy (MRS) and Diffusion Weighted MRI (DWMRI) have the potential to be helpful regarding this differentiation. MRS has the ability to measure the concentration of brain metabolites, such as Choline, Creatin and N- Acetyl Aspartate, the ratios of which have been shown to discriminate between RIN and recurrent disease. DWMRI has been linked via a rise in the Apparent Diffusion Coefficient (ADC) to successful treatment of disease. Using both of these complimentary non-invasive imaging modalities, we intend to initiate an imaging protocol whereby we will study how best to combine metabolite ratios and ADC values to obtain the most useful information in the least amount of scan time. We will look for correlations over time between ADC values, and MRS, among different sized voxels.
Assessment of Masses of the External Ear With Diffusion-Weighted MR Imaging.
Razek, Ahmed Abdel Khalek Abdel
2018-02-01
To assess masses of the external ear with diffusion-weighted MR imaging. Retrospective analysis of 43 consecutive patients with soft tissue mass of the external ear. They underwent single shot diffusion-weighted MR imaging of the ear. The apparent diffusion coefficient (ADC) value of the mass of the external ear was calculated. The final diagnosis was performed by biopsy. The ADC value correlated with the biopsy results. The mean ADC value of malignancy (=27) of external ear (0.95 ± 0.19 × 10 mm/s) was significantly lower (p = 0.001) than that of benign (n = 16) lesions (1.49 ± 0.08 × 10 mm/s). The cutoff ADC used for differentiation of malignancy from benign lesions was 1.18 × 10 mm/s with an area under the curve of 0.959, an accuracy of 93%, a sensitivity of 92%, and specificity of 93%. There was a significant difference in the ADC of well and moderately differentiated malignancy versus poorly and undifferentiated squamous cell carcinoma (p = 0.001), and stages I and II versus stages III and IV (p = 0.04) of squamous cell carcinoma. ADC value is a non-invasive promising imaging parameter that can be used for differentiation of malignancy of the external ear from benign lesions, and grading and staging of squamous cell carcinoma of the external ear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dirix, Piet; Keyzer, Frederik de; Vandecaveye, Vincent
2008-08-01
Purpose: To evaluate diffusion-weighted (DW)-MRI as a noninvasive tool to investigate major salivary gland function before and after radiotherapy (RT) for head and neck cancer (HNC). Methods and Materials: DW-MRI was performed in 8 HNC patients before and after parotid-sparing RT (mean dose to the contralateral parotid gland <26 Gy). A DW sequence was performed once at rest and then repeated continuously during salivary stimulation. Apparent diffusion coefficient (ADC) maps for both parotid and submandibular glands were calculated. Findings were compared with salivary gland scintigraphy. Results: Before RT, the mean ADC value at rest was significantly lower in the parotidmore » than in the submandibular glands. During the first 5 min of stimulation, the ADC value of the salivary glands showed a decrease, followed by a steady increase until a peak ADC, significantly higher than the baseline value, was reached after a median of 17 min. The baseline ADC value at rest was significantly higher after RT than before RT in the nonspared salivary glands but not in the spared parotid glands. In the contralateral parotid glands, the same response was seen as before RT. This pattern was completely lost in the nonspared glands. These results corresponded with remaining or loss of salivary function, respectively, as confirmed by salivary gland scintigraphy. Conclusions: Diffusion-weighted-MRI allows noninvasive evaluation of functional changes in the major salivary glands after RT and is a promising tool for investigating radiation-induced xerostomia.« less
Tokgoz, Ozlem; Unlu, Ebru; Unal, Ilker; Serifoglu, Ismail; Oz, Ilker; Aktas, Elif; Caglar, Emrah
2016-03-01
To investigate the use of diffusion weighted magnetic resonance imaging (DWI) and the apparent diffusion coefficient (ADC) values in the diagnosis of hemangioma. The study population consisted of 72 patients with liver masses larger than 1 cm (72 focal lesions). DWI examination with a b value of 600 s/mm2 was carried out for all patients. After DWI examination, an ADC map was created and ADC values were measured for 72 liver masses and normal liver tissue (control group). The average ADC values of normal liver tissue and focal liver lesions, the "cut-off" ADC values, and the diagnostic sensitivity and specificity of the ADC map in diagnosing hemangioma, benign and malignant lesions were researched. Of the 72 liver masses, 51 were benign and 21 were malignant. Benign lesions comprised 38 hemangiomas and 13 simple cysts. Malignant lesions comprised 9 hepatocellular carcinomas, and 12 metastases. The highest ADC values were measured for cysts (3.782±0.53×10(-3) mm(2)/s) and hemangiomas (2.705±0.63×10(-3) mm(2)/s). The average ADC value of hemangiomas was significantly higher than malignant lesions and the normal control group (p<0.001). The average ADC value of cysts were significantly higher when compared to hemangiomas and normal control group (p<0.001). To distinguish hemangiomas from malignant liver lesions, the "cut-off" ADC value of 1.800×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 90.9%. To distinguish hemangioma from normal liver parenchyma the "cut-off" value of 1.858×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 95.7%. To distinguish benign liver lesions from malignant liver lesions the "cut-off" value of 1.800×10(-3) mm(2)/s had a sensitivity of 96.1% and a specificity of 90.0%. DWI and quantitative measurement of ADC values can be used in differential diagnosis of benign and malignant liver lesions and also in the diagnosis and differentiation of hemangiomas. When dynamic examination cannot distinguish cases with vascular metastasis and lesions from hemangioma, DWI and ADC values can be useful in the primary diagnosis and differential diagnosis. The technique does not require contrast material, so it can safely be used in patients with renal failure.
Bi, Qiu; Xiao, Zhibo; Lv, Fajin; Liu, Yao; Zou, Chunxia; Shen, Yiqing
2018-02-05
The objective of this study was to find clinical parameters and qualitative and quantitative magnetic resonance imaging (MRI) features for differentiating uterine sarcoma from atypical leiomyoma (ALM) preoperatively and to calculate predictive values for uterine sarcoma. Data from 60 patients with uterine sarcoma and 88 patients with ALM confirmed by surgery and pathology were collected. Clinical parameters, qualitative MRI features, diffusion-weighted imaging with apparent diffusion coefficient values, and quantitative parameters of dynamic contrast-enhanced MRI of these two tumor types were compared. Predictive values for uterine sarcoma were calculated using multivariable logistic regression. Patient clinical manifestations, tumor locations, margins, T2-weighted imaging signals, mean apparent diffusion coefficient values, minimum apparent diffusion coefficient values, and time-signal intensity curves of solid tumor components were obvious significant parameters for distinguishing between uterine sarcoma and ALM (all P <.001). Abnormal vaginal bleeding, tumors located mainly in the uterine cavity, ill-defined tumor margins, and mean apparent diffusion coefficient values of <1.272 × 10 -3 mm 2 /s were significant preoperative predictors of uterine sarcoma. When the overall scores of these four predictors were greater than or equal to 7 points, the sensitivity, the specificity, the accuracy, and the positive and negative predictive values were 88.9%, 99.9%, 95.7%, 97.0%, and 95.1%, respectively. The use of clinical parameters and multiparametric MRI as predictive factors was beneficial for diagnosing uterine sarcoma preoperatively. These findings could be helpful for guiding treatment decisions. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Min, Xiangde; Feng, Zhaoyan; Wang, Liang; Cai, Jie; Yan, Xu; Li, Basen; Ke, Zan; Zhang, Peipei; You, Huijuan
2018-01-01
To assess the values of parameters derived from whole-lesion histograms of the apparent diffusion coefficient (ADC) at 3T for the characterization of testicular germ cell tumors (TGCTs). A total of 24 men with TGCTs underwent 3T diffusion-weighted imaging. Fourteen tumors were pathologically confirmed as seminomas, and ten tumors were pathologically confirmed as nonseminomas. Whole-lesion histogram analysis of the ADC values was performed. A Mann-Whitney U test was employed to compare the differences in ADC histogram parameters between seminomas and nonseminomas. Receiver operating characteristic analysis was used to identify the cutoff values for each parameter for differentiating seminomas from nonseminomas; furthermore, the area under the curve (AUC) was calculated to evaluate the diagnostic accuracy. The median of 10th, 25th, 50th, 75th, and 90th percentiles and mean, minimum and maximum ADC values were all significantly reduced for seminomas compared with nonseminomas (p<0.05 for all). In contrast, the median of kurtosis and skewness of ADC values of seminomas were both significantly increased compared with those of nonseminomas (p=0.003 and 0.001, respectively). For differentiating nonseminomas from seminomas, the 10th percentile ADC yielded the highest AUC with a sensitivity and specificity of 100% and 92.86%, respectively. Whole-lesion histogram analysis of ADCs might be used for preoperative characterization of TGCTs. Copyright © 2017 Elsevier B.V. All rights reserved.
Suzuki, Yuriko; Hori, Masaaki; Kamiya, Kouhei; Fukunaga, Issei; Aoki, Shigeki; VAN Cauteren, Marc
2016-01-01
Q-space imaging (QSI) is a diffusion-weighted imaging (DWI) technique that enables investigation of tissue microstructure. However, for sufficient displacement resolution to measure the microstructure, QSI requires high q-values that are usually difficult to achieve with a clinical scanner. The recently introduced "low q-value method" fits the echo attenuation to only low q-values to extract the root mean square displacement. We investigated the clinical feasibility of the low q-value method for estimating the microstructure of the human corpus callosum using a 3.0-tesla clinical scanner within a clinically feasible scan time. We performed a simulation to explore the acceptable range of maximum q-values for the low q-value method. We simulated echo attenuations caused by restricted diffusion in the intra-axonal space (IAS) and hindered diffusion in the extra-axonal space (EAS) assuming 100,000 cylinders with various diameters, and we estimated mean axon diameter, IAS volume fraction, and EAS diffusivity by fitting echo attenuations with different maximum q-values. Furthermore, we scanned the corpus callosum of 7 healthy volunteers and estimated the mean axon diameter and IAS volume fraction. Good agreement between estimated and defined values in the simulation study with maximum q-values of 700 and 800 cm(-1) suggested that the maximum q-value used in the in vivo experiment, 737 cm(-1), was reasonable. In the in vivo experiment, the mean axon diameter was larger in the body of the corpus callosum and smaller in the genu and splenium, and this anterior-to-posterior trend is consistent with previously reported histology, although our mean axon diameter seems larger in size. On the other hand, we found an opposite anterior-to-posterior trend, with high IAS volume fraction in the genu and splenium and a lower fraction in the body, which is similar to the fiber density reported in the histology study. The low q-value method may provide insights into tissue microstructure using a 3T clinical scanner within clinically feasible scan time.
NASA Astrophysics Data System (ADS)
Rätzke, K.; Hüppe, P. W.; Faupel, F.
1992-04-01
The isotope effect E=(Dα/Dβ-1)/[(mβ/mα)1/2-1] of cobalt diffusion has been measured in melt-spun amorphous Co76.7Fe2Nb14.3B7 ribbon at different stages of structural relaxation. A drastic drop of the isotope effect from E>0.5 in the as-quenched glass to E=0.1 in the relaxed state wass observed. While the latter value relflects highly cooperative diffusion, the large isotope effect in the as-quenched ribbon points to the prevalence of single-atom jumps and vacancylike holes of excess volume.
Correction of eddy current distortions in high angular resolution diffusion imaging.
Zhuang, Jiancheng; Lu, Zhong-Lin; Vidal, Christine Bouteiller; Damasio, Hanna
2013-06-01
To correct distortions caused by eddy currents induced by large diffusion gradients during high angular resolution diffusion imaging without any auxiliary reference scans. Image distortion parameters were obtained by image coregistration, performed only between diffusion-weighted images with close diffusion gradient orientations. A linear model that describes distortion parameters (translation, scale, and shear) as a function of diffusion gradient directions was numerically computed to allow individualized distortion correction for every diffusion-weighted image. The assumptions of the algorithm were successfully verified in a series of experiments on phantom and human scans. Application of the proposed algorithm in high angular resolution diffusion images markedly reduced eddy current distortions when compared to results obtained with previously published methods. The method can correct eddy current artifacts in the high angular resolution diffusion images, and it avoids the problematic procedure of cross-correlating images with significantly different contrasts resulting from very different gradient orientations or strengths. Copyright © 2012 Wiley Periodicals, Inc.
Mulkern, Robert V; Barnes, Agnieszka Szot; Haker, Steven J; Hung, Yin P; Rybicki, Frank J; Maier, Stephan E; Tempany, Clare M C
2006-06-01
Detailed measurements of water diffusion within the prostate over an extended b-factor range were performed to assess whether the standard assumption of monoexponential signal decay is appropriate in this organ. From nine men undergoing prostate MR staging examinations at 1.5 T, a single 10-mm-thick axial slice was scanned with a line scan diffusion imaging sequence in which 14 equally spaced b factors from 5 to 3,500 s/mm(2) were sampled along three orthogonal diffusion sensitization directions in 6 min. Due to the combination of long scan time and limited volume coverage associated with the multi-b-factor, multidirectional sampling, the slice was chosen online from the available T2-weighted axial images with the specific goal of enabling the sampling of presumed noncancerous regions of interest (ROIs) within the central gland (CG) and peripheral zone (PZ). Histology from prescan biopsy (n=9) and postsurgical resection (n=4) was subsequently employed to help confirm that the ROIs sampled were noncancerous. The CG ROIs were characterized from the T2-weighted images as primarily mixtures of glandular and stromal benign prostatic hyperplasia, which is prevalent in this population. The water signal decays with b factor from all ROIs were clearly non-monoexponential and better served with bi- vs. monoexponential fits, as tested using chi(2)-based F test analyses. Fits to biexponential decay functions yielded intersubject fast diffusion component fractions in the order of 0.73+/-0.08 for both CG and PZ ROIs, fast diffusion coefficients of 2.68+/-0.39 and 2.52+/-0.38 microm(2)/ms and slow diffusion coefficients of 0.44+/-0.16 and 0.23+/-0.16 um(2)/ms for CG and PZ ROIs, respectively. The difference between the slow diffusion coefficients within CG and PZ was statistically significant as assessed with a Mann-Whitney nonparametric test (P<.05). We conclude that a monoexponential model for water diffusion decay in prostate tissue is inadequate when a large range of b factors is sampled and that biexponential analyses are better suited for characterizing prostate diffusion decay curves.
Novel Imaging Contrast Methods for Hyperpolarized 13 C Magnetic Resonance Imaging
NASA Astrophysics Data System (ADS)
Reed, Galen Durant
Magnetic resonance imaging using hyperpolarized 13C-labeled small molecules has emerged as an extremely powerful tool for the in vivo monitoring of perfusion and metabolism. This work presents methods for improved imaging, parameter mapping, and image contrast generation for in vivo hyperpolarized 13C MRI. Angiography using hyperpolarized urea was greatly improved with a highly T2-weighted acquisition in combination with 15N labeling of the urea amide groups. This is due to the fact that the T2 of [13C]urea is strongly limited by the scalar coupling to the neighboring quadrupolar 14N. The long in vivo T2 values of [13C, 15N2]urea were utilized for sub-millimeter projection angiography using a contrast agent that could be safely injected in concentrations of 10-100 mM while still tolerated in patients with renal insufficiency. This study also presented the first method for in vivo T2 mapping of hyperpolarized 13C compounds. The in vivo T2 of urea was short in the blood and long within the kidneys. This persistent signal component was isolated to the renal filtrate, thus enabling for the first time direct detection of an imaging contrast agent undergoing glomerular filtration. While highly T2-weighted acquisitions select for molecules with short rotational correlation times, high diffusion weighting selects for those with the long translational correlation times. A specialized spin-echo EPI sequence was developed in order to generate highly diffusion-weighted hyperpolarized 13C images on a clinical MRI system operating within clinical peak- RF and gradient amplitude constraints. Low power adiabatic spin echo pulses were developed in order to generate a sufficiently large refocused bandwidth while maintaining low nominal power. This diffusion weighted acquisition gave enhanced tumor contrast-to-noise ratio when imaging [1-13C]lactate after infusion of [1-13C]pyruvate. Finally, the first in-man hyperpolarized 13C MRI clinical trial is discussed.
Impact of post-processing methods on apparent diffusion coefficient values.
Zeilinger, Martin Georg; Lell, Michael; Baltzer, Pascal Andreas Thomas; Dörfler, Arnd; Uder, Michael; Dietzel, Matthias
2017-03-01
The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on final ADC values. Sixty-five lesions scanned with a standardized whole-body DWI-protocol at 3 T served as input data (EPI-DWI, b-values: 50, 400 and 800 s/mm 2 ). Using exactly the same ROI coordinates, four different PPM (ADC_1-ADC_4) were executed to calculate corresponding ADC values, given as [10 -3 mm 2 /s] of each lesion. Statistical analysis was performed to intra-individually compare ADC values stratified by PPM (Wilcoxon signed-rank tests: α = 1 %; descriptive statistics; relative difference/∆; coefficient of variation/CV). Stratified by PPM, mean ADCs ranged from 1.136-1.206 *10 -3 mm 2 /s (∆ = 7.0 %). Variances between PPM were pronounced in the upper range of ADC values (maximum: 2.540-2.763 10 -3 mm 2 /s, ∆ = 8 %). Pairwise comparisons identified significant differences between all PPM (P ≤ 0.003; mean CV = 7.2 %) and reached 0.137 *10 -3 mm 2 /s within the 25th-75th percentile. Altering the PPM had a significant impact on the ADC value. This should be considered if ADC values from different post-processing methods are compared in patient studies. • Post-processing methods significantly influenced ADC values. • The mean coefficient of ADC variation due to PPM was 7.2 %. • To achieve reproducible ADC values, standardization of post-processing is recommended.
Multi-model Analysis of Diffusion-weighted Imaging of Normal Testes at 3.0 T: Preliminary Findings.
Min, Xiangde; Feng, Zhaoyan; Wang, Liang; Cai, Jie; Li, Basen; Ke, Zan; Zhang, Peipei; You, Huijuan; Yan, Xu
2018-04-01
This study aimed to establish diffusion quantitative parameters (apparent diffusion coefficient [ADC], DDC, α, D app , and K app ) in normal testes at 3.0 T. Sixty-four healthy volunteers in two age groups (A: 10-39 years; B: ≥ 40 years) underwent diffusion-weighted imaging scanning at 3.0 T. ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app were calculated using the mono-exponential, stretched-exponential, and kurtosis models. The correlations between parameters and the age were analyzed. The parameters were compared between the age groups and between the right and the left testes. The average ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app values did not significantly differ between the right and the left testes (P > .05 for all). The following significant correlations were found: positive correlations between age and testicular ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app (r = 0.516, 0.518, 0.518, 0.521, and 0.516, respectively; P < .01 for all) and negative correlations between age and testicular α and K app (r = -0.363, -0.427, respectively; P < .01 for both). Compared to group B, in group A, ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app were significantly lower (P < .05 for all), but α and K app were significantly higher (P < .05 for both). Our study demonstrated the applicability of the testicular mono-exponential, stretched-exponential, and kurtosis models. Our results can help establish a baseline for the normal testicular parameters in these diffusion models. The contralateral normal testis can serve as a suitable reference for evaluating the abnormalities of the other side. The effect of age on these parameters requires further attention. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Dyvorne, Hadrien A; Galea, Nicola; Nevers, Thomas; Fiel, M Isabel; Carpenter, David; Wong, Edmund; Orton, Matthew; de Oliveira, Andre; Feiweier, Thorsten; Vachon, Marie-Louise; Babb, James S; Taouli, Bachir
2013-03-01
To optimize intravoxel incoherent motion (IVIM) diffusion-weighted (DW) imaging by estimating the effects of diffusion gradient polarity and breathing acquisition scheme on image quality, signal-to-noise ratio (SNR), IVIM parameters, and parameter reproducibility, as well as to investigate the potential of IVIM in the detection of hepatic fibrosis. In this institutional review board-approved prospective study, 20 subjects (seven healthy volunteers, 13 patients with hepatitis C virus infection; 14 men, six women; mean age, 46 years) underwent IVIM DW imaging with four sequences: (a) respiratory-triggered (RT) bipolar (BP) sequence, (b) RT monopolar (MP) sequence, (c) free-breathing (FB) BP sequence, and (d) FB MP sequence. Image quality scores were assessed for all sequences. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF) in liver parenchyma. Mixed-model analysis of variance was used to compare image quality, SNR, IVIM parameters, and interexamination variability between the four sequences, as well as the ability to differentiate areas of liver fibrosis from normal liver tissue. Image quality with RT sequences was superior to that with FB acquisitions (P = .02) and was not affected by gradient polarity. SNR did not vary significantly between sequences. IVIM parameter reproducibility was moderate to excellent for PF and D, while it was less reproducible for D*. PF and D were both significantly lower in patients with hepatitis C virus than in healthy volunteers with the RT BP sequence (PF = 13.5% ± 5.3 [standard deviation] vs 9.2% ± 2.5, P = .038; D = [1.16 ± 0.07] × 10(-3) mm(2)/sec vs [1.03 ± 0.1] × 10(-3) mm(2)/sec, P = .006). The RT BP DW imaging sequence had the best results in terms of image quality, reproducibility, and ability to discriminate between healthy and fibrotic liver with biexponential fitting.
O'Flynn, Elizabeth A M; Blackledge, Matthew; Collins, David; Downey, Katherine; Doran, Simon; Patel, Hardik; Dumonteil, Sam; Mok, Wing; Leach, Martin O; Koh, Dow-Mu
2016-07-01
To evaluate the diagnostic sensitivity of computed diffusion-weighted (DW)-MR imaging for the detection of breast cancer. Local research ethics approval was obtained. A total of 61 women (median 48 years) underwent dynamic contrast enhanced (DCE)- and DW-MR between January 2011 and March 2012, including 27 with breast cancer on core biopsy and 34 normal cases. Standard ADC maps using all four b values (0, 350, 700, 1150) were used to generate computed DW-MR images at b = 1500 s/mm(2) and b = 2000 s/mm(2) . Four image sets were read sequentially by two readers: acquired b = 1150 s/mm(2) , computed b = 1500 s/mm(2) and b = 2000 s/mm(2) , and DCE-MR at an early time point. Cancer detection was rated using a five-point scale; image quality and background suppression were rated using a four-point scale. The diagnostic sensitivity for breast cancer detection was compared using the McNemar test and inter-reader agreement with a Kappa value. Computed DW-MR resulted in higher overall diagnostic sensitivity with b = 2000 s/mm(2) having a mean diagnostic sensitivity of 76% (range 49.8-93.7%) and b = 1500 s/mm(2) having a mean diagnostic sensitivity of 70.3% (range 32-97.7%) compared with 44.4% (range 25.5-64.7%) for acquired b = 1150 s/mm(2) (both p = 0.0001). Computed DW-MR images produced better image quality and background suppression (mean scores for both readers: 2.55 and 2.9 for b 1500 s/mm(2) ; 2.55 and 3.15 for b 2000 s/mm(2) , respectively) than the acquired b value 1150 s/mm(2) images (mean scores for both readers: 2.4 and 2.45, respectively). Computed DW-MR imaging has the potential to improve the diagnostic sensitivity of breast cancer detection compared to acquired DW-MR. J. Magn. Reson. Imaging 2016;44:130-137. © 2016 Wiley Periodicals, Inc.
Resolving power for the diffusion orientation distribution function.
Jensen, Jens H; Helpern, Joseph A
2016-08-01
The diffusion orientation distribution function (dODF) is primarily used for white matter fiber tractography. Here the resolving power of the dODF is investigated for a simple diffusion model of two intersecting axonal fiber bundles. The resolving power for the dODF is evaluated using the Sparrow criterion. This is determined for the exact dODF and also for q-space imaging (QSI), q-ball, and kurtosis approximations. Based on theoretical and numerical calculations, the resolving power is found to depend on the eigenvalues of the diffusion model and on the degree of radial weighting for the dODF. The resolving powers of the QSI and q-ball dODFs improve with increased b-value. The kurtosis dODF has a resolving power similar to that of the exact dODF. The dODFs, whether exact or approximate, have finite resolving powers that limit their sensitivity to fiber crossings. The resolving powers for the different dODFs considered here provide convenient benchmarks for assessing and comparing their performance. Magn Reson Med 76:679-688, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Rapid in vivo apparent diffusion coefficient mapping of hyperpolarized (13) C metabolites.
Koelsch, Bertram L; Reed, Galen D; Keshari, Kayvan R; Chaumeil, Myriam M; Bok, Robert; Ronen, Sabrina M; Vigneron, Daniel B; Kurhanewicz, John; Larson, Peder E Z
2015-09-01
Hyperpolarized (13) C magnetic resonance allows for the study of real-time metabolism in vivo, including significant hyperpolarized (13) C lactate production in many tumors. Other studies have shown that aggressive and highly metastatic tumors rapidly transport lactate out of cells. Thus, the ability to not only measure the production of hyperpolarized (13) C lactate but also understand its compartmentalization using diffusion-weighted MR will provide unique information for improved tumor characterization. We used a bipolar, pulsed-gradient, double spin echo imaging sequence to rapidly generate diffusion-weighted images of hyperpolarized (13) C metabolites. Our methodology included a simultaneously acquired B1 map to improve apparent diffusion coefficient (ADC) accuracy and a diffusion-compensated variable flip angle scheme to improve ADC precision. We validated this sequence and methodology in hyperpolarized (13) C phantoms. Next, we generated ADC maps of several hyperpolarized (13) C metabolites in a normal rat, rat brain tumor, and prostate cancer mouse model using both preclinical and clinical trial-ready hardware. ADC maps of hyperpolarized (13) C metabolites provide information about the localization of these molecules in the tissue microenvironment. The methodology presented here allows for further studies to investigate ADC changes due to disease state that may provide unique information about cancer aggressiveness and metastatic potential. © 2014 Wiley Periodicals, Inc.
Reduction of diffusional defocusing in hydrodynamically focused flows
Affleck, Rhett L.; Demas, James N.; Goodwin, Peter M.; Keller, Richard; Wu, Ming
1998-01-01
An analyte fluid stream with first molecules having relatively low molecular weight and a corresponding high coefficient of diffusion has reduced diffusional defocusing out of an analyte fluid stream. The analyte fluid stream of first molecules is associated with second molecules of relatively high molecular weight having a relatively low coefficient of diffusion and a binding constant effective to associate with the first molecules. A focused analyte fluid stream is maintained since the combined molecular weight of the associated first and second molecules is effective to minimize diffusion of the first molecules out of the analyte fluid stream.
Reduction of diffusional defocusing in hydrodynamically focused flows
Affleck, R.L.; Demas, J.N.; Goodwin, P.M.; Keller, R.; Wu, M.
1998-09-01
An analyte fluid stream with first molecules having relatively low molecular weight and a corresponding high coefficient of diffusion has reduced diffusional defocusing out of an analyte fluid stream. The analyte fluid stream of first molecules is associated with second molecules of relatively high molecular weight having a relatively low coefficient of diffusion and a binding constant effective to associate with the first molecules. A focused analyte fluid stream is maintained since the combined molecular weight of the associated first and second molecules is effective to minimize diffusion of the first molecules out of the analyte fluid stream. 6 figs.
Molecular imaging of malignant tumor metabolism: whole-body image fusion of DWI/CT vs. PET/CT.
Reiner, Caecilia S; Fischer, Michael A; Hany, Thomas; Stolzmann, Paul; Nanz, Daniel; Donati, Olivio F; Weishaupt, Dominik; von Schulthess, Gustav K; Scheffel, Hans
2011-08-01
To prospectively investigate the technical feasibility and performance of image fusion for whole-body diffusion-weighted imaging (wbDWI) and computed tomography (CT) to detect metastases using hybrid positron emission tomography/computed tomography (PET/CT) as reference standard. Fifty-two patients (60 ± 14 years; 18 women) with different malignant tumor disease examined by PET/CT for clinical reasons consented to undergo additional wbDWI at 1.5 Tesla. WbDWI was performed using a diffusion-weighted single-shot echo-planar imaging during free breathing. Images at b = 0 s/mm(2) and b = 700 s/mm(2) were acquired and apparent diffusion coefficient (ADC) maps were generated. Image fusion of wbDWI and CT (from PET/CT scan) was performed yielding for wbDWI/CT fused image data. One radiologist rated the success of image fusion and diagnostic image quality. The presence or absence of metastases on wbDWI/CT fused images was evaluated together with the separate wbDWI and CT images by two different, independent radiologists blinded to results from PET/CT. Detection rate and positive predictive values for diagnosing metastases was calculated. PET/CT examinations were used as reference standard. PET/CT identified 305 malignant lesions in 39 of 52 (75%) patients. WbDWI/CT image fusion was technically successful and yielded diagnostic image quality in 73% and 92% of patients, respectively. Interobserver agreement for the evaluation of wbDWI/CT images was κ = 0.78. WbDWI/CT identified 270 metastases in 43 of 52 (83%) patients. Overall detection rate and positive predictive value of wbDWI/CT was 89% (95% CI, 0.85-0.92) and 94% (95% CI, 0.92-0.97), respectively. WbDWI/CT image fusion is technically feasible in a clinical setting and allows the diagnostic assessment of metastatic tumor disease detecting nine of 10 lesions as compared with PET/CT. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Shenoy-Bhangle, Anuradha S; Nimkin, Katherine; Aranson, Thomas; Gee, Michael S
2016-01-01
MR enterography is increasingly utilized for noninvasive evaluation of disease activity in young patients with Crohn disease and has great impact on clinical management. Diffusion-weighted imaging (DWI) is a rapid MR imaging technique that measures molecular diffusion of water and is sensitive to the inflammatory process; however, its value to MR enterography has not been rigorously evaluated. To determine whether the addition of DWI to MR enterography is helpful in evaluating Crohn disease activity in young patients when compared to a histological reference. In this single-institution retrospective study, we searched an imaging database for the period January 2010 to December 2012 to identify patients age 19 years and younger who had MR enterography with diffusion-weighted imaging (DWI). We used an electronic medical record search to identify those who had MR enterography and colonoscopy performed within 28 days of each other. All MR enterography scans were performed on a 1.5-T or 3-T clinical MR scanner with phased-array torso coil configuration using standard pulse sequences as well as axial DWI with b values of 50, 400 and 800. Bowel segments were evaluated for disease activity based on standard MR enterography sequences; in addition, segmental apparent diffusion coefficient (ADC) values were calculated based on DWI. Histological reference for disease activity was based on assessment for mucosal inflammatory changes on endoscopic biopsy. MR enterography and DWI evaluation were performed in a blinded fashion with respect to histological results. We included imaging of 78 bowel segments from 27 patients (mean age 14.5 ± 3.02 years) with known Crohn disease in the study. The mean ADC for bowel segments with active disease was 1.56 ± 0.7 × 10(3) mm(2)/s compared with 2.58 ± 1.4 × 10(3) mm(2)/s for segments without active disease, a difference that was statistically significant (P < 0.01, Student's t-test). Using a threshold value of 2.0 × 10(3) mm(2)/s, DWI demonstrated lower accuracy (64.1%) but higher sensitivity (78.8%) for detecting active disease compared with standard MR enterography (69.2% and 54.6%, respectively). Combining DWI with MR enterography, using DWI as the initial screen and MR enterography afterward to reduce false negativity, led to a significant increase in accuracy (76.9%; P = 0.03, McNemar's test) compared with either imaging technique alone. Although DWI does not perform as well as standard MR enterography for detection of active Crohn disease, the combination of DWI and MR enterography increases imaging accuracy for determining disease activity compared with either technique alone. These results indicate that DWI adds value to MR enterography and supports the incorporation of DWI into MR enterography protocols for evaluation of Crohn disease in young patients.
Anomalous thermal diffusivity in underdoped YBa2Cu3O6+x
Levenson-Falk, Eli M.; Ramshaw, B. J.; Bonn, D. A.; Liang, Ruixing; Hardy, W. N.; Hartnoll, Sean A.; Kapitulnik, Aharon
2017-01-01
The thermal diffusivity in the ab plane of underdoped YBCO crystals is measured by means of a local optical technique in the temperature range of 25–300 K. The phase delay between a point heat source and a set of detection points around it allows for high-resolution measurement of the thermal diffusivity and its in-plane anisotropy. Although the magnitude of the diffusivity may suggest that it originates from phonons, its anisotropy is comparable with reported values of the electrical resistivity anisotropy. Furthermore, the anisotropy drops sharply below the charge order transition, again similar to the electrical resistivity anisotropy. Both of these observations suggest that the thermal diffusivity has pronounced electronic as well as phononic character. At the same time, the small electrical and thermal conductivities at high temperatures imply that neither well-defined electron nor phonon quasiparticles are present in this material. We interpret our results through a strongly interacting incoherent electron–phonon “soup” picture characterized by a diffusion constant D∼vB2τ, where vB is the soup velocity, and scattering of both electrons and phonons saturates a quantum thermal relaxation time τ∼ℏ/kBT. PMID:28484003
Schmid-Tannwald, C; Schmid-Tannwald, C M; Morelli, J N; Neumann, R; Reiser, M F; Nikolaou, K; Rist, C
2014-07-01
To evaluate the role of diffusion-weighted magnetic resonance imaging (DW-MRI) in the differentiation of hepatic abscesses from non-infected fluid collections. In this retrospective study, 22 hepatic abscesses and 27 non-infected hepatic fluid collections were examined in 27 patients who underwent abdominal MRI including DW-MRI. Two independent observers reviewed T2-weighted + DW-MRI and T2-weighted + contrast-enhanced T1-weighted (CET1W) images in two sessions. Detection rates and confidence levels were calculated and compared using McNemar's and Wilcoxon's signed rank tests, respectively. Apparent diffusion coefficient (ADC) values of abscesses and non-infected fluid collections were compared using the t-test. Receiver operating characteristic (ROC) curves were constructed. There was no statistically significant difference in the accuracy of detecting abscesses using T2-weighted + DW-MRI (both observers: 21/22, 95.5%) versus T2-weighted + CET1W images (observer 1: 21/22, 95.5%; observer 2: 22/22, 100%; p < 0.01). Mean ADC values were significantly lower with abscesses versus non-infected fluid collections (0.83 ± 0.24 versus 2.25 ± 0.61 × 10(-3) mm(2)/s; p < 0.001). With ROC analysis there was good discrimination of abscess from non-infected fluid collections at a threshold ADC value of 1.36 × 10(-3) mm(2)/s. DW-MRI allows qualitative and quantitative differentiation of abscesses from non-infected fluid collections in the liver. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Murayama, Kazuhiro; Katada, Kazuhiro; Hayakawa, Motoharu; Toyama, Hiroshi
We aimed to clarify the cause of shortened mean transit time (MTT) in acute ischemic cerebrovascular disease and examined its relationship with reperfusion. Twenty-three patients with acute ischemic cerebrovascular disease underwent whole-brain computed tomography perfusion (CTP). The maximum MTT (MTTmax), minimum MTT (MTTmin), ratio of maximum and minimum MTT (MTTmin/max), and minimum cerebral blood volume (CBV) (CBVmin) were measured by automatic region of interest analysis. Diffusion weighted image was performed to calculate infarction volume. We compared these CTP parameters between reperfusion and nonreperfusion groups and calculated correlation coefficients between the infarction core volume and CTP parameters. Significant differences were observed between reperfusion and nonreperfusion groups (MTTmin/max: P = 0.014; CBVmin ratio: P = 0.038). Regression analysis of CTP and high-intensity volume on diffusion weighted image showed negative correlation (CBVmin ratio: r = -0.41; MTTmin/max: r = -0.30; MTTmin ratio: r = -0.27). A region of shortened MTT indicated obstructed blood flow, which was attributed to the singular value decomposition method error.
Lin, Wei-Ching; Chen, Jeon-Hor
2015-01-01
Adequately selecting a therapeutic approach for bladder cancer depends on accurate grading and staging. Substantial inaccuracy of clinical staging with bimanual examination, cystoscopy, and transurethral resection of bladder tumor has facilitated the increasing utility of magnetic resonance imaging to evaluate bladder cancer. Diffusion-weighted imaging (DWI) is a noninvasive functional magnetic resonance imaging technique. The high tissue contrast between cancers and surrounding tissues on DWI is derived from the difference of water molecules motion. DWI is potentially a useful tool for the detection, characterization, and staging of bladder cancers; it can also monitor posttreatment response and provide information on predicting tumor biophysical behaviors. Despite advancements in DWI techniques and the use of quantitative analysis to evaluate the apparent diffusion coefficient values, there are some inherent limitations in DWI interpretation related to relatively poor spatial resolution, lack of cancer specificity, and lack of standardized image acquisition protocols and data analysis procedures that restrict the application of DWI and reproducibility of apparent diffusion coefficient values. In addition, inadequate bladder distension, artifacts, thinness of bladder wall, cancerous mimickers of normal bladder wall and benign lesions, and variations in the manifestation of bladder cancer may interfere with diagnosis and monitoring of treatment. Recognition of these pitfalls and limitations can minimize their impact on image interpretation, and carefully applying the analyzed results and combining with pathologic grading and staging to clinical practice can contribute to the selection of an adequate treatment method to improve patient care. PMID:26055180
NASA Astrophysics Data System (ADS)
He, Ting; Fan, Ming; Zhang, Peng; Li, Hui; Zhang, Juan; Shao, Guoliang; Li, Lihua
2018-03-01
Breast cancer can be classified into four molecular subtypes of Luminal A, Luminal B, HER2 and Basal-like, which have significant differences in treatment and survival outcomes. We in this study aim to predict immunohistochemistry (IHC) determined molecular subtypes of breast cancer using image features derived from tumor and peritumoral stroma region based on diffusion weighted imaging (DWI). A dataset of 126 breast cancer patients were collected who underwent preoperative breast MRI with a 3T scanner. The apparent diffusion coefficients (ADCs) were recorded from DWI, and breast image was segmented into regions comprising the tumor and the surrounding stromal. Statistical characteristics in various breast tumor and peritumoral regions were computed, including mean, minimum, maximum, variance, interquartile range, range, skewness, and kurtosis of ADC values. Additionally, the difference of features between each two regions were also calculated. The univariate logistic based classifier was performed for evaluating the performance of the individual features for discriminating subtypes. For multi-class classification, multivariate logistic regression model was trained and validated. The results showed that the tumor boundary and proximal peritumoral stroma region derived features have a higher performance in classification compared to that of the other regions. Furthermore, the prediction model using statistical features, difference features and all the features combined from these regions generated AUC values of 0.774, 0.796 and 0.811, respectively. The results in this study indicate that ADC feature in tumor and peritumoral stromal region would be valuable for estimating the molecular subtype in breast cancer.
Yang, Rui-Meng; Li, Long; Wei, Xin-Hua; Guo, Yong-Mei; Huang, Yun-Hai; Lai, Li-Sha; Chen, A-Mei; Liu, Guo-Shun; Xiong, Wei-Feng; Luo, Liang-Ping; Jiang, Xin-Qing
2013-01-01
Objective Prospectively assess the performance of diffusion-weighted magnetic resonance imaging (DW-MRI) for differentiation of central lung cancer from atelectasis. Materials and Methods 38 consecutive lung cancer patients (26 males, 12 females; age range: 28–71 years; mean age: 49 years) who were referred for thoracic MR imaging examinations were enrolled. MR examinations were performed using a 1.5-T clinical scanner and scanning sequences of T1WI, T2WI, and DWI. Cancers and atelectasis were measured by mapping of the apparent diffusion coefficients (ADCs) obtained with a b-value of 500 s/mm2. Results PET/CT and DW-MR allowed differentiation of tumor and atelectasis in all 38 cases, but T2WI did not allow differentiation in 9 cases. Comparison of conventional T2WI and DW-MRI indicated a higher contrast noise ratio of the central lung carcinoma than the atelectasis by DW-MRI. ADC maps indicated significantly lower mean ADC in the central lung carcinoma than in the atelectasis (1.83±0.58 vs. 2.90±0.26 mm2/s, p<0.0001). ADC values of small cell lung carcinoma were significantly greater than those from squamous cell carcinoma and adenocarcinoma (p<0.0001 for both). Conclusions DW-MR imaging provides valuable information not obtained by conventional MR and may be useful for differentiation of central lung carcinoma from atelectasis. Future developments may allow DW-MR imaging to be used as an alternative to PET-CT in imaging of patients with lung cancer. PMID:23593186
Radial q-space sampling for DSI.
Baete, Steven H; Yutzy, Stephen; Boada, Fernando E
2016-09-01
Diffusion spectrum imaging (DSI) has been shown to be an effective tool for noninvasively depicting the anatomical details of brain microstructure. Existing implementations of DSI sample the diffusion encoding space using a rectangular grid. Here we present a different implementation of DSI whereby a radially symmetric q-space sampling scheme for DSI is used to improve the angular resolution and accuracy of the reconstructed orientation distribution functions. Q-space is sampled by acquiring several q-space samples along a number of radial lines. Each of these radial lines in q-space is analytically connected to a value of the orientation distribution functions at the same angular location by the Fourier slice theorem. Computer simulations and in vivo brain results demonstrate that radial diffusion spectrum imaging correctly estimates the orientation distribution functions when moderately high b-values (4000 s/mm2) and number of q-space samples (236) are used. The nominal angular resolution of radial diffusion spectrum imaging depends on the number of radial lines used in the sampling scheme, and only weakly on the maximum b-value. In addition, the radial analytical reconstruction reduces truncation artifacts which affect Cartesian reconstructions. Hence, a radial acquisition of q-space can be favorable for DSI. Magn Reson Med 76:769-780, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Wurnig, Moritz C; Germann, Manon; Boss, Andreas
2018-01-01
The most commonly applied model for the description of diffusion-weighted imaging (DWI) data in perfused organs is bicompartmental intravoxel incoherent motion (IVIM) analysis. In this study, we assessed the ground truth of underlying diffusion components in healthy abdominal organs using an extensive DWI protocol and subsequent computation of apparent diffusion coefficient 'spectra', similar to the computation of previously described T 2 relaxation spectra. Diffusion datasets of eight healthy subjects were acquired in a 3-T magnetic resonance scanner using 68 different b values during free breathing (equidistantly placed in the range 0-1005 s/mm 2 ). Signal intensity curves as a function of the b value were analyzed in liver, spleen and kidneys using non-negative least-squares fitting to a distribution of decaying exponential functions with minimum amplitude energy regularization. In all assessed organs, the typical slow- and fast-diffusing components of the IVIM model were detected [liver: true diffusion D = (1.26 ± 0.01) × 10 -3 mm 2 /s, pseudodiffusion D* = (270 ± 44) × 10 -3 mm 2 /s; kidney cortex: D = (2.26 ± 0.07) × 10 -3 mm 2 /s, D* = (264 ± 78) × 10 -3 mm 2 /s; kidney medulla: D = (1.57 ± 0.28) × 10 -3 mm 2 /s, D* = (168 ± 18) × 10 -3 mm 2 /s; spleen: D = (0.91 ± 0.01) × 10 -3 mm 2 /s, D* = (69.8 ± 0.50) × 10 -3 mm 2 /s]. However, in the liver and kidney, a third component between D and D* was found [liver: D' = (43.8 ± 5.9) × 10 -3 mm 2 /s; kidney cortex: D' = (23.8 ± 11.5) × 10 -3 mm 2 /s; kidney medulla: D' = (5.23 ± 0.93) × 10 -3 mm 2 /s], whereas no third component was detected in the spleen. Fitting with a diffusion kurtosis model did not lead to a better fit of the resulting curves to the acquired data compared with apparent diffusion coefficient spectrum analysis. For a most accurate description of diffusion properties in the liver and the kidneys, a more sophisticated model seems to be required including three diffusion components. Copyright © 2017 John Wiley & Sons, Ltd.
Wada, Masae; Hasegawa, Daisuke; Hamamoto, Yuji; Yu, Yoshihiko; Fujiwara-Igarashi, Aki; Fujita, Michio
2017-07-01
Although MRI has become widely used in small animal practice, little is known about the validity of advanced MRI techniques such as diffusion-weighted imaging and diffusion tensor imaging. The aim of this retrospective analytical observational study was to investigate the characteristics of diffusion parameters, that is the apparent diffusion coefficient and fractional anisotropy, in dogs with a solitary intracranial meningioma or histiocytic sarcoma. Dogs were included based on the performance of diffusion MRI and histological confirmation. Statistical analyses were performed to compare apparent diffusion coefficient and fractional anisotropy for the two types of tumor in the intra- and peritumoral regions. Eleven cases with meningioma and six with histiocytic sarcoma satisfied the inclusion criteria. Significant differences in apparent diffusion coefficient value (× 10 -3 mm 2 /s) between meningioma vs. histiocytic sarcoma were recognized in intratumoral small (1.07 vs. 0.76) and large (1.04 vs. 0.77) regions of interest, in the peritumoral margin (0.93 vs. 1.08), and in the T2 high region (1.21 vs. 1.41). Significant differences in fractional anisotropy values were found in the peritumoral margin (0.29 vs. 0.24) and the T2 high region (0.24 vs. 0.17). The current study identified differences in measurements of apparent diffusion coefficient and fractional anisotropy for meningioma and histiocytic sarcoma in a small sample of dogs. In addition, we observed that all cases of intracranial histiocytic sarcoma showed leptomeningeal enhancement and/or mass formation invading into the sulci in the contrast study. Future studies are needed to determine the sensitivity of these imaging characteristics for differentiating between these tumor types. © 2017 American College of Veterinary Radiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, Sibani; Biswas, Sampa; Chakrabarti, Chandana
2005-06-01
Ervatamin A is a papain-family cysteine protease with high activity and stability. It has been isolated and purified from the latex of the medicinal flowering plant E. coronaria and crystallized by the vapour-diffusion technique. Crystals diffracted to 2.1 Å and the structure was solved by molecular replacement. The ervatamins are highly stable cysteine proteases that are present in the latex of the medicinal plant Ervatamia coronaria and belong to the papain family, members of which share similar amino-acid sequences and also a similar fold comprising two domains. Ervatamin A from this family, a highly active protease compared with others frommore » the same source, has been purified to homogeneity by ion-exchange chromatography and crystallized by the vapour-diffusion method. Needle-shaped crystals of ervatamin A diffract to 2.1 Å resolution and belong to space group C222{sub 1}, with unit-cell parameters a = 31.10, b = 144.17, c = 108.61 Å. The solvent content using an ervatamin A molecular weight of 27.6 kDa is 43.9%, with a V{sub M} value of 2.19 Å{sup 3} Da{sup −1} assuming one protein molecule in the asymmetric unit. A molecular-replacement solution has been found using the structure of ervatamin C as a search model.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mickiewicz, Rafal A.; Ntoukas, Eleftherios; Avgeropoulos, Apostolos
2009-08-26
Binary blends of four different high molecular weight poly(styrene-b-isoprene) (SI) diblock copolymers with a lower molecular weight poly(styrene-b-isoprene-b-styrene) (SIS) triblock copolymer were prepared, and their morphology was characterized by transmission electron microscopy and ultra-small-angle X-ray scattering. All the neat block copolymers have nearly symmetric composition and exhibit the lamellar morphology. The SI diblock copolymers had number-average molecular weights, Mn, in the range 4.4 x 10{sup 5}--1.3 x 10{sup 6} g/mol and volume fractions of poly(styrene), {Phi}{sub PS}, in the range 0.43--0.49, and the SIS triblock had a molecular weight of Mn 6.2 x 10{sup 4} g/mol with {Phi}{sub PS} =more » 0.41. The high molecular weight diblock copolymers are very strongly segregating, with interaction parameter values, {chi}N, in the range 470--1410. A morphological phase diagram in the parameter space of molecular weight ratio (R = M{sub n}{sup diblock}/1/2M{sub n}{sup triblock}) and blend composition was constructed, with R values in the range between 14 and 43, which are higher than previously reported. The phase diagram revealed a large miscibility gap for the blends, with macrophase separation into two distinct types of microphase-separated domains for weight fractions of SI, w{sub SI} < 0.9, implying virtually no solubility of the much higher molecular weight diblocks in the lower molecular weight triblock. For certain blend compositions, above R 30, morphological transitions from the lamellar to cylindrical and bicontinuous structures were also observed.« less
Added Value of Assessing Adnexal Masses with Advanced MRI Techniques
Thomassin-Naggara, I.; Balvay, D.; Rockall, A.; Carette, M. F.; Ballester, M.; Darai, E.; Bazot, M.
2015-01-01
This review will present the added value of perfusion and diffusion MR sequences to characterize adnexal masses. These two functional MR techniques are readily available in routine clinical practice. We will describe the acquisition parameters and a method of analysis to optimize their added value compared with conventional images. We will then propose a model of interpretation that combines the anatomical and morphological information from conventional MRI sequences with the functional information provided by perfusion and diffusion weighted sequences. PMID:26413542
Ni, Jing; Wang, Yong-Qing; Zhang, Ying-Ping; Wu, Wei; Zeng, Qing-Shu; Yang, Ming-Zhen; Xia, Rui-Xiang
2016-04-01
To investigate the predictive value of neutrophil/lymphocyte ratio (NLR) and platelet/lymphocyte ratio (PLR) for the patients with diffuse large B-cell lymphoma (DLBCL). The clinical data of 57 DLBCL patients admitted in the First Affiliated hospital of Anhui Medical University were analyzed retrospectively. According to ROC curve, the cut-off value for NLR and PLR was deterimined, and the patients were divided into high and low NLR/PLR groups before first chamotherapy. Then the relation of NLR and PLR with overall survival (OS) and progression-free survival (PFS) was analyzed by univariate and multivariate COX regression. The optimal cut-off value for NLR and PLR was 2.915 and 270.27, respectively. NLR at the diagnosis was found to be an independent predictor for OS and PFS by univariate and multivariate analysis, while the PLR was an independent predictor for PFS, but did not affect the OS. NLR and PLR may provide additional prognostic information for DLBCL patients.
Loh, K B; Ramli, N; Tan, L K; Roziah, M; Rahmat, K; Ariffin, H
2012-07-01
The degree and status of white matter myelination can be sensitively monitored using diffusion tensor imaging (DTI). This study looks at the measurement of fractional anistropy (FA) and mean diffusivity (MD) using an automated ROI with an existing DTI atlas. Anatomical MRI and structural DTI were performed cross-sectionally on 26 normal children (newborn to 48 months old), using 1.5-T MRI. The automated processing pipeline was implemented to convert diffusion-weighted images into the NIfTI format. DTI-TK software was used to register the processed images to the ICBM DTI-81 atlas, while AFNI software was used for automated atlas-based volumes of interest (VOIs) and statistical value extraction. DTI exhibited consistent grey-white matter contrast. Triphasic temporal variation of the FA and MD values was noted, with FA increasing and MD decreasing rapidly early in the first 12 months. The second phase lasted 12-24 months during which the rate of FA and MD changes was reduced. After 24 months, the FA and MD values plateaued. DTI is a superior technique to conventional MR imaging in depicting WM maturation. The use of the automated processing pipeline provides a reliable environment for quantitative analysis of high-throughput DTI data. Diffusion tensor imaging outperforms conventional MRI in depicting white matter maturation. • DTI will become an important clinical tool for diagnosing paediatric neurological diseases. • DTI appears especially helpful for developmental abnormalities, tumours and white matter disease. • An automated processing pipeline assists quantitative analysis of high throughput DTI data.
2018-06-25
Diffuse Large B-Cell Lymphoma Activated B-Cell Type; Diffuse Large B-Cell Lymphoma, Not Otherwise Specified; High Grade B-Cell Lymphoma, Not Otherwise Specified; Recurrent Burkitt Lymphoma; Recurrent Diffuse Large B-Cell Lymphoma; Refractory Burkitt Lymphoma; Refractory Diffuse Large B-Cell Lymphoma
Rabasco, Paola; Caivano, Rocchina; Simeon, Vittorio; Dinardo, Giuseppina; Lotumolo, Antonella; Gioioso, Matilde; Villonio, Antonio; Iannelli, Giancarlo; D'Antuono, Felice; Zandolino, Alexis; Macarini, Luca; Guglielmi, Giuseppe; Cammarota, Aldo
2017-02-07
To analyze diffusion-weighted imaging (DWI) and the related apparent diffusion coefficient (ADC) in women with breast cancer, correlating these values with the presence at 3 years of distant metastases, and to demonstrate that DWI-Magnetic Resonance Imaging (MRI) and related ADC values may represent a prognostic value in the study of women with breast cancer. Sixty women (aged 45-73 years) affected with breast cancer with a follow-up in 3 years were enrolled. On DWI, we obtained the ADC values, and these were correlated with the clinical condition of patients at 3 years. Moreover, tumour size, lymph node status, and molecular markers, including estrogens receptor, progesterone receptor, Ki-67 index, and human growth factor receptor 2 protein, were correlated with ADC values. This study was approved by the Scientific Committee of our institution. We considered patients with metastasis at 3 years (12 patients - 20%) and without metastasis (48 patients - 80%). The mean ADC value in patients with no metastases at 3 years was 1.06 ± 0.38, while for patients with metastases it was 0.74 ± 0.34 (p = .011). The receiver-operator curve analysis identified a value of 0.75 (<0.75 with risk to develop metastasis) as the best predictive cutoff for ADC values, with the highest sensitivity (81.25%) and higher specificity (66.67%). After regression analysis, ADC value, positivity to estrogen-progestin receptors, and presence of lymph nodes were the only prognostic factors found to be statistically significant. DWI-MRI and related ADC values may represent a prognostic value in women with breast cancer.
Kida, Ikuhiro; Ueguchi, Takashi; Matsuoka, Yuichiro; Zhou, Kun; Stemmer, Alto; Porter, David
2016-07-01
The purpose of the present study was to compare periodically rotated overlapping parallel lines with enhanced reconstruction-type turbo spin echo diffusion-weighted imaging (pTSE-DWI) and readout-segmented echo planar imaging (rsEPI-DWI) with single-shot echo planar imaging (ssEPI-DWI) in a 7 T human MR system. We evaluated the signal-to-noise ratio (SNR), image distortion, and apparent diffusion coefficient values in the human brain. Six healthy volunteers were included in this study. The study protocol was approved by our institutional review board. All measurements were performed at 7 T using pTSE-DWI, rsEPI-DWI, and ssEPI-DWI sequences. The spatial resolution was 1.2 × 1.2 mm in-plane with a 3-mm slice thickness. Signal-to-noise ratio was measured using 2 scans. The ssEPI-DWI sequence showed significant image blurring, whereas pTSE-DWI and rsEPI-DWI sequences demonstrated high image quality with low geometrical distortion compared with reference T2-weighted, turbo spin echo images. Signal loss in ventral regions near the air-filled paranasal sinus/nasal cavity was found in ssEPI-DWI and rsEPI-DWI but not pTSE-DWI. The apparent diffusion coefficient values for ssEPI-DWI were 824 ± 17 × 10 and 749 ± 25 × 10 mm/s in the gray matter and white matter, respectively; the values obtained for pTSE-DWI were 798 ± 21 × 10 and 865 ± 40 × 10 mm/s; and the values obtained for rsEPI-DWI were 730 ± 12 × 10 and 722 ± 25 × 10 mm/s. The pTSE-DWI images showed no additional distortion comparison to the T2-weighted images, but had a lower SNR than ssEPI-DWI and rsEPI-DWI. The rsEPI-DWI sequence provided high-quality images with minor distortion and a similar SNR to ssEPI-DWI. Our results suggest that the benefits of the rsEPI-DWI and pTSE-DWI sequences, in terms of SNR, image quality, and image distortion, appear to outweigh those of ssEPI-DWI. Thus, pTSE-DWI and rsEPI-DWI at 7 T have great potential use for clinical diagnoses. However, it is noteworthy that both sequences are limited by the scan time required. In addition, pTSE-DWI has limitations on the number of slices due to specific absorption rate. Overall, rsEPI-DWI is a favorable imaging sequence, taking into account the SNR and image quality at 7 T.
Single-shot ADC imaging for fMRI.
Song, Allen W; Guo, Hua; Truong, Trong-Kha
2007-02-01
It has been suggested that apparent diffusion coefficient (ADC) contrast can be sensitive to cerebral blood flow (CBF) changes during brain activation. However, current ADC imaging techniques have an inherently low temporal resolution due to the requirement of multiple acquisitions with different b-factors, as well as potential confounds from cross talk between the deoxyhemoglobin-induced background gradients and the externally applied diffusion-weighting gradients. In this report a new method is proposed and implemented that addresses these two limitations. Specifically, a single-shot pulse sequence that sequentially acquires one gradient-echo (GRE) and two diffusion-weighted spin-echo (SE) images was developed. In addition, the diffusion-weighting gradient waveform was numerically optimized to null the cross terms with the deoxyhemoglobin-induced background gradients to fully isolate the effect of diffusion weighting from that of oxygenation-level changes. The experimental results show that this new single-shot method can acquire ADC maps with sufficient signal-to-noise ratio (SNR), and establish its practical utility in functional MRI (fMRI) to complement the blood oxygenation level-dependent (BOLD) technique and provide differential sensitivity for different vasculatures to better localize neural activity originating from the small vessels. Copyright (c) 2007 Wiley-Liss, Inc.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Capolongo, Arcangela; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2014-07-01
Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions. 90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3)mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated. In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of >1.44 and 37 (70%) with ADC≤1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively. DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement. Copyright © 2014 Elsevier Inc. All rights reserved.
Kimura, Hidehito; Taniguchi, Masaaki; Mori, Tatsuya; Hosoda, Kohkichi; Kohmura, Eiji
2017-01-01
Postoperative hyperperfusion syndrome after extracranial-to-intracranial bypass causing temporary neurologic deterioration has been reported rarely as isosignal intensity on diffusion-weighted imaging (DWI) with hyperintense lesion on T2-weighted image and fluid-attenuated inversion recovery (FLAIR) imaging as an expression of vasogenic edema. We present a rare case of a patient suffering from temporary aphasia after an extracranial-to-intracranial bypass surgery, which was shown as a transient hypointense lesion on DWI with increased apparent diffusion coefficient value, evidence of postoperative hyperperfusion. By the preoperative single-photon emission computed tomography study analyzed retrospectively, preoperative cerebral blood flow (CBF) was compared between the lesions in which the hypointensity emerged and the lesions in which its signal remained unchanged in the hyperperfusion area. We found CBF after an acetazolamide challenge was much smaller and the percentage increase of CBF after an acetazolamide challenge was much less than zero in the temporal hypointense lesion on DWI. An abrupt increase of CBF after bypass installation to the brain with no vascular response and complete disruption of the blood-brain barrier would cause a remarkable increase of extracellular fluid and excessive water molecule diffusion, resulting in excessive vasogenic edema. This was a plausible mechanism for the transient hypointense lesion on DWI with increased apparent diffusion coefficient value. Copyright © 2016 Elsevier Inc. All rights reserved.
2018-06-11
ALK-Positive Large B-Cell Lymphoma; Atypical Burkitt/Burkitt-Like Lymphoma; Burkitt-Like Lymphoma With 11q Aberration; Diffuse Large B-Cell Lymphoma Activated B-Cell Type; Diffuse Large B-Cell Lymphoma Associated With Chronic Inflammation; Diffuse Large B-Cell Lymphoma Germinal Center B-Cell Type; Diffuse Large B-Cell Lymphoma, Not Otherwise Specified; EBV-Positive Diffuse Large B-Cell Lymphoma, Not Otherwise Specified; EBV-Positive Mucocutaneous Ulcer; High-Grade B-Cell Lymphoma With MYC, BCL2, and BCL6 Rearrangements; Human Herpesvirus 8-Positive Neoplastic Cells Present; Intravascular Large B-Cell Lymphoma; Large B-Cell Lymphoma With IRF4 Rearrangement; Plasmablastic Lymphoma; Primary Cutaneous Diffuse Large B-Cell Lymphoma; Primary Cutaneous Diffuse Large B-Cell Lymphoma, Leg Type; Primary Diffuse Large B-Cell Lymphoma of the Central Nervous System; Primary Effusion Lymphoma; Recurrent B-Cell Lymphoma, Unclassifiable, With Features Intermediate Between Diffuse Large B-Cell Lymphoma and Classic Hodgkin Lymphoma; Recurrent Burkitt Lymphoma; Recurrent Diffuse Large B-Cell Lymphoma; Recurrent Lymphomatoid Granulomatosis; Recurrent Primary Mediastinal (Thymic) Large B-Cell Cell Lymphoma; Refractory B-Cell Lymphoma, Unclassifiable, With Features Intermediate Between Diffuse Large B-Cell Lymphoma and Classic Hodgkin Lymphoma; Refractory Burkitt Lymphoma; Refractory Diffuse Large B-Cell Lymphoma; Refractory Primary Mediastinal (Thymic) Large B-Cell Cell Lymphoma; Small Intestinal High Grade B-Cell Lymphoma, Not Otherwise Specified; T-Cell/Histiocyte-Rich Large B-Cell Lymphoma
Deridder, Sander; Vanmessen, Alison; Nakanishi, Kazuki; Desmet, Gert; Cabooter, Deirdre
2014-07-18
Effective medium theory (EMT) expressions for the B-term band broadening in monolithic silica columns are presented at the whole-column as well as at the mesoporous skeleton level. Given the bi-continuous nature of the monolithic medium, regular as well as inverse formulations of the EMT-expressions have been established. The established expressions were validated by applying them to a set of experimental effective diffusion (Deff)-data obtained via peak parking on a number of 1st and 2nd generation monolithic silica columns, as well as to a set of numerical diffusion simulations in a simplified monolithic column representation (tetrahedral skeleton model) with different external porosities and internal diffusion coefficients. The numerically simulated diffusion data can be very closely represented over a very broad range of zone retention factors (up to k″=80) using the established EMT-expressions, especially when using the inverse variant. The expressions also allow representing the experimentally measured effective diffusion data very closely. The measured Deff/Dmol-values were found to decrease significantly with increasing retention factor, in general going from about Deff/Dmol=0.55 to 0.65 at low k″ (k″≅1.5-3.8) to Deff/Dmol=0.25 at very high k″ (k″≅40-80). These values are significantly larger than observed in fully-porous and core-shell particles. The intra-skeleton diffusion coefficient (Dpz) was typically found to be of the order of Dpz/Dmol=0.4, compared to Dpz/Dmol=0.2-0.35 observed in most particle-based columns. These higher Dpz/Dmol values are the cause of the higher Deff/Dmol values observed. In addition, it also appears that the higher internal diffusion is linked to the higher porosity of the mesoporous skeleton that has a relatively open structure with relatively wide pores. The observed (weak) relation between Dpz/Dmol and the zone retention factor appears to be in good agreement with that predicted when applying the regular variant of the EMT-expression directly to the mesoporous skeleton level. Copyright © 2014 Elsevier B.V. All rights reserved.
Çabuk, Gonca; Nass Duce, Meltem; Özgür, Anıl; Apaydın, Feramuz Demir; Polat, Ayşe; Orekici, Gülhan
2015-04-01
The goal of our study was to evaluate the diagnostic efficacy of diffusion-weighted imaging (DWI) in the differentiation of benign and malignant breast lesions. Between June 2012 and March 2013, 60 patients with 63 lesions (age range 29-70 years, mean age 48.6 years) were included in our study. All lesions, except complicated cysts and intra-mammary lymph nodes, were confirmed histopathologically. The patients were evaluated with a 1.5 Tesla MR scanner using dedicated bilateral breast coil. DWI images were obtained by echo planar imaging sequence and 'b' values were selected as 200, 600 and 1000 s/mm(2). Apparent diffusion coefficient (ADC) values of both breast lesions and the normal fibroglandular tissue of the contralateral breast were calculated and statistically compared using Shapiro-Wilk test, Student's t-test, Mann-Whitney U test, chi-square test and the receiver operating curve. Of 63 lesions, 22 were malignant and 41 were benign. In malignant lesions, the mean ADC values were 1.40 ± 0.41 × 10(-3) mm(2)/s for b = 200, 1.05 ± 0.28 × 10(-3) mm(2)/s for b = 600 and 0.91 ± 0.20 × 10(-3) mm(2)/s for b = 1000 and in benign lesions, the mean ADC values were 2.13 ± 0.85 × 10(-3) mm(2)/s for b = 200, 1.64 ± 0.47 × 10(-3) mm(2)/s for b = 600 and 1.40 ± 0.43 × 10(-3) mm(2)/s for b = 1000. The success of ADC values in differentiation of benign and malignant lesions was statistically significant (P = 0.0001). The threshold values were determined to be 1.50 × 10(-3) mm(2)/s for b = 200, 1.22 × 10(-3) mm(2)/s for b = 600 and 0.98 × 10(-3) mm(2)/s for b = 1000 (P < 0.05). DWI can be an effective radiological method in the differentiation of benign and malignant breast lesions. © 2015 The Royal Australian and New Zealand College of Radiologists.
Detecting prostate cancer and prostatic calcifications using advanced magnetic resonance imaging
Dou, Shewei; Bai, Yan; Shandil, Ankit; Ding, Degang; Shi, Dapeng; Haacke, E Mark; Wang, Meiyun
2017-01-01
Prostate cancer and prostatic calcifications have a high incidence in elderly men. We aimed to investigate the diagnostic capabilities of susceptibility-weighted imaging in detecting prostate cancer and prostatic calcifications. A total number of 156 men, including 34 with prostate cancer and 122 with benign prostate were enrolled in this study. Computed tomography, conventional magnetic resonance imaging, diffusion-weighted imaging, and susceptibility-weighted imaging were performed on all the patients. One hundred and twelve prostatic calcifications were detected in 87 patients. The sensitivities and specificities of the conventional magnetic resonance imaging, apparent diffusion coefficient, and susceptibility-filtered phase images in detecting prostate cancer and prostatic calcifications were calculated. McNemar's Chi-square test was used to compare the differences in sensitivities and specificities between the techniques. The results showed that the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic cancer were greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). In addition, the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic calcifications were comparable to that of computed tomography and greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). Given the high incidence of susceptibility-weighted imaging (SWI) abnormality in prostate cancer, we conclude that susceptibility-weighted imaging is more sensitive and specific than conventional magnetic resonance imaging, diffusion-weighted imaging, and computed tomography in detecting prostate cancer. Furthermore, susceptibility-weighted imaging can identify prostatic calcifications similar to computed tomography, and it is much better than conventional magnetic resonance imaging and diffusion-weighted imaging. PMID:27004542
Detecting prostate cancer and prostatic calcifications using advanced magnetic resonance imaging.
Dou, Shewei; Bai, Yan; Shandil, Ankit; Ding, Degang; Shi, Dapeng; Haacke, E Mark; Wang, Meiyun
2017-01-01
Prostate cancer and prostatic calcifications have a high incidence in elderly men. We aimed to investigate the diagnostic capabilities of susceptibility-weighted imaging in detecting prostate cancer and prostatic calcifications. A total number of 156 men, including 34 with prostate cancer and 122 with benign prostate were enrolled in this study. Computed tomography, conventional magnetic resonance imaging, diffusion-weighted imaging, and susceptibility-weighted imaging were performed on all the patients. One hundred and twelve prostatic calcifications were detected in 87 patients. The sensitivities and specificities of the conventional magnetic resonance imaging, apparent diffusion coefficient, and susceptibility-filtered phase images in detecting prostate cancer and prostatic calcifications were calculated. McNemar's Chi-square test was used to compare the differences in sensitivities and specificities between the techniques. The results showed that the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic cancer were greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). In addition, the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic calcifications were comparable to that of computed tomography and greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). Given the high incidence of susceptibility-weighted imaging (SWI) abnormality in prostate cancer, we conclude that susceptibility-weighted imaging is more sensitive and specific than conventional magnetic resonance imaging, diffusion-weighted imaging, and computed tomography in detecting prostate cancer. Furthermore, susceptibility-weighted imaging can identify prostatic calcifications similar to computed tomography, and it is much better than conventional magnetic resonance imaging and diffusion-weighted imaging.
Wang, Xin-Yan; Yan, Fei; Hao, Hui; Wu, Jian-Xing; Chen, Qing-Hua; Xian, Jun-Fang
2015-01-01
Background: Differentiating benign from malignant sinonsal lesions is essential for treatment planning as well as determining the patient's prognosis, but the differentiation is often difficult in clinical practice. The study aimed to determine whether the combination of diffusion-weighted (DW) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can improve the performance in differentiating benign from malignant sinonasal tumors. Methods: This retrospective study included 197 consecutive patients with sinonasal tumors (116 malignant tumors and 81 benign tumors). All patients underwent both DW and DCE-MRI in a 3-T magnetic resonance scanner. Two different settings of b values (0,700 and 0,1000 s/mm2) and two different strategies of region of interest (ROI) including whole slice (WS) and partial slice (PS) were used to calculate apparent diffusion coefficients (ADCs). A DW parameter with WS ADCsb0,1000 and two DCE-MRI parameters (time intensity curve [TIC] and time to peak enhancement [Tpeak]) were finally combined to use in differentiating the benign from the malignant tumors in this study. Results: The mean ADCs of malignant sinonasal tumors (WS ADCsb0,1000 = 1.084 × 10−3 mm2/s) were significantly lower than those of benign tumors (WS ADCsb0,1000 = 1.617 × 10−3 mm2/s, P < 0.001). The accuracy using WS ADCsb0,1000 alone was 83.7% in differentiating the benign from the malignant tumors (85.3% sensitivity, 81.2% specificity, 86.4% positive predictive value [PPV], and 79.5% negative predictive value [NPV]). The accuracy using DCE with Tpeak and TIC alone was 72.1% (69.1% sensitivity, 74.1% specificity, 77.5% PPV, and 65.1% NPV). Using DW-MRI parameter was superior than using DCE parameters in differentiation between benign and malignant sinonasal tumors (P < 0.001). The accuracy was 87.3% (90.5% sensitivity, 82.7% specificity, 88.2% PPV, and 85.9% NPV) using DW-MRI combined with DCE-MRI, which was superior than that using DCE-MRI alone or using DW-MRI alone (both P < 0.001) in differentiating the benign from the malignant tumors. Conclusions: Diffusion-weighted combined with DCE-MRI can improve imaging performance in differentiating benign from malignant sinonasal tumors, which has the potential to improve diagnostic accuracy and to provide added value in the management for these tumors. PMID:25698188
Li, Xiulei; Wang, Ling; Li, Yong; Song, Peiji
2017-10-01
This study aimed to investigate the value of diffusion-weighted imaging (DWI) in combination with conventional magnetic resonance imaging (MRI) for improving tumor detection in young patients treated with fertility-sparing surgery because of early cervical carcinoma. Fifty-four patients with stage Ia or Ib1 cervical carcinoma were enrolled into this study. Magnetic resonance examinations were performed for these patients using conventional MRI (including T1-weighted imaging, T2-weighted imaging, and dynamic contrast-enhanced MRI) and DWI. The apparent diffusion coefficient (ADC) values of cervical carcinoma were analyzed quantitatively and compared with that of adjacent epithelium. Sensitivity, positive predictive value, and accuracy of 2 sets of MRI sequences were calculated on the basis of histologic results, and the diagnostic ability of conventional MRI/DWI combinations was compared with that of conventional MRI. The mean ADC value from cervical carcinoma (mean, 786 × 10 mm/s ± 100) was significantly lower than that from adjacent epithelium (mean, 1352 × 10 mm/s ± 147) (P = 0.01). When the threshold ADC value set as 1010 × 10 mm/s, the sensitivity and specificity for differentiating cervical carcinoma from nontumor epithelium were 78.2% and 67.2%, respectively. The sensitivity and accuracy of conventional MRI for tumor detection were 76.0% and 70.4%, whereas the sensitivity and accuracy of conventional MRI/DWI combinations were 91.7% and 90.7%, respectively. Conventional MRI/DWI combinations revealed a positive predictive value of 97.8% and only 4 false-negative findings. The addition of DWI to conventional MRI considerably improves the sensitivity and accuracy of tumor detection in young patients treated with fertility-sparing surgery, which supports the inclusion quantitative analysis of ADC value in routine MRI protocol before fertility-sparing surgery.
Bonekamp, David; Bonekamp, Susanne; Ou, Hsin-You; Torbenson, Michael S; Corona-Villalobos, Celia Pamela; Mezey, Esteban; Kamel, Ihab R
2014-11-01
Noninvasive markers have been developed to reduce the need for liver biopsy. The aim of this study was to compare the strength of association of the arterial enhancement fraction (AEF), apparent diffusion coefficient (ADC), and serum biomarkers for staging hepatic fibrosis. Eighty-five patients with chronic liver disease underwent triple-phase contrast-enhanced MRI, used to calculate AEF, and diffusion-weighted MRI (b = 0,750 s/mm(2) ), used to calculate ADC. Hepatic fibrosis was staged according METAVIR criteria. The overall association of the four biomarkers (AEF, ADC, aspartate aminotransferase (AST)/alanine aminotransferase (ALT) ratio, and aspartate aminotransferase to platelet ratio index [APRI]) was compared using nonparametric tests and receiver operating characteristic (ROC) curve, using histopathologic analysis as the reference standard. AEF and ADC values differed significantly between histopathologic fibrosis stages. AEF values correlated with fibrosis stage, ADC values correlated negatively with fibrosis stage. Compared with ADC, AEF showed a trend toward an improved capability of discriminating fibrosis stages. A weighted composite score of AEF and ADC had significantly better diagnostic accuracy than ADC alone (P ≤ 0.023). Imaging parameters had a significantly better diagnostic accuracy than AST/ALT ratio or APRI. AEF may be able to detect the presence of mild, moderate, and advanced liver fibrosis, and its value is increased with concomitant use of ADC. © 2013 Wiley Periodicals, Inc.
Vargas, Hebert Alberto; Lakhman, Yulia; Sudre, Romain; Do, Richard K. G.; Bibeau, Frederic; Azria, David; Assenat, Eric; Molinari, Nicolas; Pierredon, Marie-Ange; Rouanet, Philippe; Guiu, Boris
2016-01-01
Purpose To determine the diagnostic performance of intravoxel incoherent motion (IVIM) parameters and apparent diffusion coefficient (ADC) to assess response to combined chemotherapy and radiation therapy (CRT) in patients with rectal cancer by using histogram analysis derived from whole-tumor volumes and single-section regions of interest (ROIs). Materials and Methods The institutional review board approved this retrospective study of 31 patients with rectal cancer who underwent magnetic resonance (MR) imaging before and after CRT, including diffusion-weighted imaging with 34 b values prior to surgery. Patient consent was not required. ADC, perfusion-related diffusion fraction (f), slow diffusion coefficient (D), and fast diffusion coefficient (D*) were calculated on MR images acquired before and after CRT by using biexponential fitting. ADC and IVIM histogram metrics and median values were obtained by using whole-tumor volume and single-section ROI analyses. All ADC and IVIM parameters obtained before and after CRT were compared with histopathologic findings by using t tests with Holm-Sidak correction. Receiver operating characteristic curves were generated to evaluate the diagnostic performance of IVIM parameters derived from whole-tumor volume and single-section ROIs for prediction of histopathologic response. Results Extreme values aside, results of histogram analysis of ADC and IVIM were equivalent to median values for tumor response assessment (P > .06). Prior to CRT, none of the median ADC and IVIM diffusion metrics correlated with subsequent tumor response (P > .36). Median D and ADC values derived from either whole-volume or single-section analysis increased significantly after CRT (P ≤ .01) and were significantly higher in good versus poor responders (P ≤ .02). Median IVIM f and D* values did not significantly change after CRT and were not associated with tumor response to CRT (P > .36). Interobserver agreement was excellent for whole-tumor volume analysis (range, 0.91–0.95) but was only moderate for single-section ROI analysis (range, 0.50–0.63). Conclusion Median D and ADC values obtained after CRT were useful for discrimination between good and poor responders. Histogram metrics did not add to the median values for assessment of tumor response. Volumetric analysis demonstrated better interobserver reproducibility when compared with single-section ROI analysis. © RSNA, 2016 Online supplemental material is available for this article. PMID:26919562
Adubeiro, Nuno; Nogueira, Maria Luísa; Nunes, Rita G; Ferreira, Hugo Alexandre; Ribeiro, Eduardo; La Fuente, José Maria Ferreira
Determining optimal b-value pair for differentiation between normal and prostate cancer (PCa) tissues. Forty-three patients with diagnosis or PCa symptoms were included. Apparent diffusion coefficient (ADC) was estimated using minimum and maximum b-values of 0, 50, 100, 150, 200, 500s/mm2 and 500, 800, 1100, 1400, 1700 and 2000s/mm2, respectively. Diagnostic performances were evaluated when Area-under-the-curve (AUC)>95%. 15 of the 35 b-values pair surpassed this AUC threshold. The pair (50, 2000s/mm2) provided the highest AUC (96%) with ADC cutoff 0.89×10- 3 mm 2 /s, sensitivity 95.5%, specificity 93.2% and accuracy 94.4%. The best b-value pair was b=50, 2000s/mm2. Copyright © 2017 Elsevier Inc. All rights reserved.
Diamond, Kevin R; Farrell, Thomas J; Patterson, Michael S
2003-12-21
Steady-state diffusion theory models of fluorescence in tissue have been investigated for recovering fluorophore concentrations and fluorescence quantum yield. Spatially resolved fluorescence, excitation and emission reflectance Carlo simulations, and measured using a multi-fibre probe on tissue-simulating phantoms containing either aluminium phthalocyanine tetrasulfonate (AlPcS4), Photofrin meso-tetra-(4-sulfonatophenyl)-porphine dihydrochloride The accuracy of the fluorophore concentration and fluorescence quantum yield recovered by three different models of spatially resolved fluorescence were compared. The models were based on: (a) weighted difference of the excitation and emission reflectance, (b) fluorescence due to a point excitation source or (c) fluorescence due to a pencil beam excitation source. When literature values for the fluorescence quantum yield were used for each of the fluorophores, the fluorophore absorption coefficient (and hence concentration) at the excitation wavelength (mu(a,x,f)) was recovered with a root-mean-square accuracy of 11.4% using the point source model of fluorescence and 8.0% using the more complicated pencil beam excitation model. The accuracy was calculated over a broad range of optical properties and fluorophore concentrations. The weighted difference of reflectance model performed poorly, with a root-mean-square error in concentration of about 50%. Monte Carlo simulations suggest that there are some situations where the weighted difference of reflectance is as accurate as the other two models, although this was not confirmed experimentally. Estimates of the fluorescence quantum yield in multiple scattering media were also made by determining mu(a,x,f) independently from the fitted absorption spectrum and applying the various diffusion theory models. The fluorescence quantum yields for AlPcS4 and TPPS4 were calculated to be 0.59 +/- 0.03 and 0.121 +/- 0.001 respectively using the point source model, and 0.63 +/- 0.03 and 0.129 +/- 0.002 using the pencil beam excitation model. These results are consistent with published values.
Takayama, Yukihisa; Nishie, Akihiro; Asayama, Yoshiki; Ishigami, Kousei; Kakihara, Daisuke; Ushijima, Yasuhiro; Fujita, Nobuhiro; Yoshiura, Takashi; Takemura, Atsushi; Obara, Makoto; Takahara, Taro; Honda, Hiroshi
2015-01-01
We compared the image quality of free-breathing diffusion-weighted imaging (FB-DWI) to that of respiratory-triggered DWI (RT-DWI) after proper optimization. Three healthy subjects were scanned to optimize magnetic resonance (MR) parameters of FB-DWI to improve image quality, including spatial resolution, image noise, and chemical shift artifacts. After this optimization, we scanned 32 patients with liver disease to assess the clinical feasibility of the optimized FB-DWI. Of the 32 patients, 14 had a total of 28 hepatocellular carcinomas (HCCs), four had a total of 15 metastatic liver tumors, and the other 14 had no tumor. Qualitatively, we compared the image quality scores of FB-DWI with those of RT-DWI with the Wilcoxon signed-rank test. Quantitatively, we compared the signal-to-noise ratios (SNRs) of the liver parenchyma, lesion-to-nonlesion contrast-to-noise ratios (CNRs) and apparent diffusion coefficient (ADC) values of the liver parenchyma and liver tumor by the paired t-test. The average scores of image quality for sharpness of liver contour, image noise, and chemical shift artifacts were significantly higher for FB-DWI than RT-DWI (P < 0.05). SNRs, CNRs, and ADC values of the liver parenchyma and tumors did not differ significantly between the 2 DWI methods. Compared with RT-DWI, the optimized FB-DWI provided better spatial resolution, fewer artifacts, and comparable SNRs, lesion-to-nonlesion CNRs, and ADC values.
Risk factors for hyperbilirubinemia in breastfed term neonates.
Chen, Ying-Juang; Chen, Wei-Chuan; Chen, Chung-Ming
2012-01-01
Increased breastfeeding was suggested as a contributing factor to significant hyperbilirubinemia. The aim of this study was to identify the risk factors associated with jaundice in exclusively breastfed term neonates. We retrospectively reviewed all consecutively live-born neonates from August 2009 to July 2010 who had complete outpatient department (OPD) follow-up at ≤14 days old. Hyperbilirubinemia was defined as a transcutaneous bilirubin (TcB) value of ≥15 mg/dl. During the study period, there were 718 deliveries, of which 152 neonates were transferred to the special care nursery or neonatal intensive care unit; 566 neonates were discharged from the nursery, and 243 neonates were excluded: 83 did not return to the OPD, 46 were older than 14 days at OPD follow-up, 44 were <37 weeks of gestational age, and 70 had been fed formula. In total, 323 neonates were enrolled and classified into the hyperbilirubinemic (114 neonates) and non-hyperbilirubinemic groups (209 neonates). The gender, gestational age, Apgar score, age at nursery discharge, birth weight, and body weight at nursery discharge and at OPD were comparable between the two groups. TcB values at nursery discharge were positively correlated with TcB values in the OPD. Infants with hyperbilirubinemia exhibited significantly greater body weight loss from birth to the OPD follow-up and significantly less body weight gain from nursery discharge to OPD follow-up. High TcB values at nursery discharge and a smaller body weight gain are associated with hyperbilirubinemia in term neonates who are exclusively breastfed.
Li, Ying; Mei, Lihong; Qiang, Jinwei; Ju, Shuai; Zhao, Shuhui
2016-12-01
Portal-systemic encephalopathy (PSE) is classified as type B hepatic encephalopathy. Portal-systemic shunting rather than liver dysfunction is the main cause of PSE in chronic hepatic schistosomiasis japonicum (HSJ) patients. Owing to lack of detectable evidence of intrinsic liver disease, chronic HSJ patients with PSE are frequently clinically undetected or misdiagnosed, especially chronic HSJ patients with covert PSE (subclinical encephalopathy). In this study, we investigated whether magnetic resonance spectroscopy (MRS) could be a useful tool for diagnosing PSE in chronic HSJ patients. Magnetic resonance (MR) T1-weighted imaging, diffusion-weighted imaging, and MRS were performed in 41 chronic HSJ patients with suspected PSE and in 21 age-matched controls. The T1 signal intensity index (T1SI) and apparent diffusion coefficient (ADC) value were obtained in the Globus pallidus. Liver function was also investigated via serum ammonia and liver function tests. Higher T1SI and ADC values, increased lactate and glutamine levels, and decreased myo-inositol were found in the bilateral Globus pallidus in chronic HSJ patients with PSE. No significantly abnormal serum ammonia or liver function tests were observed in chronic HSJ patients with PSE. On the basis of these findings, we propose a diagnostic procedure for PSE in chronic HSJ patients. This study reveals that MRS can be useful for diagnosing PSE in chronic HSJ patients.
NASA Astrophysics Data System (ADS)
Jerome, N. P.; Orton, M. R.; d'Arcy, J. A.; Feiweier, T.; Tunariu, N.; Koh, D.-M.; Leach, M. O.; Collins, D. J.
2015-01-01
Respiratory motion commonly confounds abdominal diffusion-weighted magnetic resonance imaging, where averaging of successive samples at different parts of the respiratory cycle, performed in the scanner, manifests the motion as blurring of tissue boundaries and structural features and can introduce bias into calculated diffusion metrics. Storing multiple averages separately allows processing using metrics other than the mean; in this prospective volunteer study, median and trimmed mean values of signal intensity for each voxel over repeated averages and diffusion-weighting directions are shown to give images with sharper tissue boundaries and structural features for moving tissues, while not compromising non-moving structures. Expert visual scoring of derived diffusion maps is significantly higher for the median than for the mean, with modest improvement from the trimmed mean. Diffusion metrics derived from mono- and bi-exponential diffusion models are comparable for non-moving structures, demonstrating a lack of introduced bias from using the median. The use of the median is a simple and computationally inexpensive alternative to complex and expensive registration algorithms, requiring only additional data storage (and no additional scanning time) while returning visually superior images that will facilitate the appropriate placement of regions-of-interest when analysing abdominal diffusion-weighted magnetic resonance images, for assessment of disease characteristics and treatment response.
Jerome, N P; Orton, M R; d'Arcy, J A; Feiweier, T; Tunariu, N; Koh, D-M; Leach, M O; Collins, D J
2015-01-21
Respiratory motion commonly confounds abdominal diffusion-weighted magnetic resonance imaging, where averaging of successive samples at different parts of the respiratory cycle, performed in the scanner, manifests the motion as blurring of tissue boundaries and structural features and can introduce bias into calculated diffusion metrics. Storing multiple averages separately allows processing using metrics other than the mean; in this prospective volunteer study, median and trimmed mean values of signal intensity for each voxel over repeated averages and diffusion-weighting directions are shown to give images with sharper tissue boundaries and structural features for moving tissues, while not compromising non-moving structures. Expert visual scoring of derived diffusion maps is significantly higher for the median than for the mean, with modest improvement from the trimmed mean. Diffusion metrics derived from mono- and bi-exponential diffusion models are comparable for non-moving structures, demonstrating a lack of introduced bias from using the median. The use of the median is a simple and computationally inexpensive alternative to complex and expensive registration algorithms, requiring only additional data storage (and no additional scanning time) while returning visually superior images that will facilitate the appropriate placement of regions-of-interest when analysing abdominal diffusion-weighted magnetic resonance images, for assessment of disease characteristics and treatment response.
Spin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart
von Deuster, Constantin; Stoeck, Christian T.; Genet, Martin; Atkinson, David
2015-01-01
Purpose To compare signal‐to‐noise ratio (SNR) efficiency and diffusion tensor metrics of cardiac diffusion tensor mapping using acceleration‐compensated spin‐echo (SE) and stimulated echo acquisition mode (STEAM) imaging. Methods Diffusion weighted SE and STEAM sequences were implemented on a clinical 1.5 Tesla MR system. The SNR efficiency of SE and STEAM was measured (b = 50–450 s/mm2) in isotropic agar, anisotropic diffusion phantoms and the in vivo human heart. Diffusion tensor analysis was performed on mean diffusivity, fractional anisotropy, helix and transverse angles. Results In the isotropic phantom, the ratio of SNR efficiency for SE versus STEAM, SNRt(SE/STEAM), was 2.84 ± 0.08 for all tested b‐values. In the anisotropic diffusion phantom the ratio decreased from 2.75 ± 0.05 to 2.20 ± 0.13 with increasing b‐value, similar to the in vivo decrease from 2.91 ± 0.43 to 2.30 ± 0.30. Diffusion tensor analysis revealed reduced deviation of helix angles from a linear transmural model and reduced transverse angle standard deviation for SE compared with STEAM. Mean diffusivity and fractional anisotropy were measured to be statistically different (P < 0.001) between SE and STEAM. Conclusion Cardiac DTI using motion‐compensated SE yields a 2.3–2.9× increase in SNR efficiency relative to STEAM and improved accuracy of tensor metrics. The SE method hence presents an attractive alternative to STEAM based approaches. Magn Reson Med 76:862–872, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:26445426
Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup
2018-01-01
The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.
Yamada, Haruyasu; Abe, Osamu; Shizukuishi, Takashi; Kikuta, Junko; Shinozaki, Takahiro; Dezawa, Ko; Nagano, Akira; Matsuda, Masayuki; Haradome, Hiroki; Imamura, Yoshiki
2014-01-01
Diffusion imaging is a unique noninvasive tool to detect brain white matter trajectory and integrity in vivo. However, this technique suffers from spatial distortion and signal pileup or dropout originating from local susceptibility gradients and eddy currents. Although there are several methods to mitigate these problems, most techniques can be applicable either to susceptibility or eddy-current induced distortion alone with a few exceptions. The present study compared the correction efficiency of FSL tools, “eddy_correct” and the combination of “eddy” and “topup” in terms of diffusion-derived fractional anisotropy (FA). The brain diffusion images were acquired from 10 healthy subjects using 30 and 60 directions encoding schemes based on the electrostatic repulsive forces. For the 30 directions encoding, 2 sets of diffusion images were acquired with the same parameters, except for the phase-encode blips which had opposing polarities along the anteroposterior direction. For the 60 directions encoding, non–diffusion-weighted and diffusion-weighted images were obtained with forward phase-encoding blips and non–diffusion-weighted images with the same parameter, except for the phase-encode blips, which had opposing polarities. FA images without and with distortion correction were compared in a voxel-wise manner with tract-based spatial statistics. We showed that images corrected with eddy and topup possessed higher FA values than images uncorrected and corrected with eddy_correct with trilinear (FSL default setting) or spline interpolation in most white matter skeletons, using both encoding schemes. Furthermore, the 60 directions encoding scheme was superior as measured by increased FA values to the 30 directions encoding scheme, despite comparable acquisition time. This study supports the combination of eddy and topup as a superior correction tool in diffusion imaging rather than the eddy_correct tool, especially with trilinear interpolation, using 60 directions encoding scheme. PMID:25405472
Yamada, Haruyasu; Abe, Osamu; Shizukuishi, Takashi; Kikuta, Junko; Shinozaki, Takahiro; Dezawa, Ko; Nagano, Akira; Matsuda, Masayuki; Haradome, Hiroki; Imamura, Yoshiki
2014-01-01
Diffusion imaging is a unique noninvasive tool to detect brain white matter trajectory and integrity in vivo. However, this technique suffers from spatial distortion and signal pileup or dropout originating from local susceptibility gradients and eddy currents. Although there are several methods to mitigate these problems, most techniques can be applicable either to susceptibility or eddy-current induced distortion alone with a few exceptions. The present study compared the correction efficiency of FSL tools, "eddy_correct" and the combination of "eddy" and "topup" in terms of diffusion-derived fractional anisotropy (FA). The brain diffusion images were acquired from 10 healthy subjects using 30 and 60 directions encoding schemes based on the electrostatic repulsive forces. For the 30 directions encoding, 2 sets of diffusion images were acquired with the same parameters, except for the phase-encode blips which had opposing polarities along the anteroposterior direction. For the 60 directions encoding, non-diffusion-weighted and diffusion-weighted images were obtained with forward phase-encoding blips and non-diffusion-weighted images with the same parameter, except for the phase-encode blips, which had opposing polarities. FA images without and with distortion correction were compared in a voxel-wise manner with tract-based spatial statistics. We showed that images corrected with eddy and topup possessed higher FA values than images uncorrected and corrected with eddy_correct with trilinear (FSL default setting) or spline interpolation in most white matter skeletons, using both encoding schemes. Furthermore, the 60 directions encoding scheme was superior as measured by increased FA values to the 30 directions encoding scheme, despite comparable acquisition time. This study supports the combination of eddy and topup as a superior correction tool in diffusion imaging rather than the eddy_correct tool, especially with trilinear interpolation, using 60 directions encoding scheme.
Mulkern, Robert V.; Barnes, Agnieszka Szot; Haker, Steven J.; Hung, Yin P.; Rybicki, Frank J.; Maier, Stephan E.; Tempany, Clare M.C.
2006-01-01
Detailed measurements of water diffusion within the prostate over an extended b-factor range were performed to assess whether the standard assumption of monoexponential signal decay is appropriate in this organ. From nine men undergoing prostate MR staging exams at 1.5 T, a single 10 mm thick axial slice was scanned with a line scan diffusion imaging (LSDI) sequence in which 14 equally spaced b- factors from 5 to 3500 s/mm2 were sampled along three orthogonal diffusion sensitization directions in 6 minutes. Due to the combination of long scan time and limited volume coverage associated with the multi-b- factor, multi-directional sampling, the slice was chosen online from the available T2-weighted axial images with the specific goal of enabling the sampling of presumed non-cancerous regions of interest (ROI’s) within the central gland (CG) and peripheral zone (PZ). Histology from pre-scan biopsy (N = 9) and post-surgical resection (N = 4) was subsequently employed to help confirm that the ROIs sampled were non-cancerous. The CG ROIs were characterized from the T2-weighted images as primarily mixtures of glandular and stromal benign prostatic hyperplasia (BPH) which is prevalent in this population. The water signal decays with b- factor from all ROI’s were clearly non-monoexponential and better served with bi- vs monoexponential fits, as tested using λ2 based F-test analyses. Fits to biexponential decay functions yielded inter-subject fast diffusion component fractions on the order of 0.73 ± 0.08 for both CG and PZ ROIs, fast diffusion coefficients of 2.68 ± 0.39 and 2.52 ± 0.38 μm2/ms and slow diffusion coefficients of 0.44 ± 0.16 and 0.23 ± 0.16 um2/ms for CG and PZ ROI’s, respectively. The difference between the slow diffusion coefficients within CG and PZ was statistically significant as assessed with a Mann-Whitney non-parametric test (P < 0.05). We conclude that a monoexponential model for water diffusion decay in prostate tissue is inadequate when a large range of b- factors is sampled and that biexponential analyses are better suited for characterizing prostate diffusion decay curves. PMID:16735177
NASA Astrophysics Data System (ADS)
Marin, Andrew; Munoz-Rojas, David; Iza, Diana; Gershon, Talia; MacManus-Driscoll, Judith
2011-03-01
In-plane (parallel to the substrate) polymer diffusion at and near interfaces has significant implications for polymeric surfactants used in tertiary oil recovery, exfoliation of clay sheets in polymer nano-composites, and several other high technology applications. Here, we report a study on the in-plane diffusion of whole polymer chains confined between interfaces using fluorescence recovery after photobleaching. Adapted from quantitative biology, FRAP provides a platform to independently study the effect of temperature, molecular weight, and film thickness on in-plane diffusion of polymers confined between interfaces. Fluorescently labeled polymers were synthesized, spin coated onto quartz substrates and the self-diffusion coefficient was measured by irreversibly photobleaching fluorophores in a pre-defined pattern and monitoring recovery of fluorescence over time. Preliminary results indicate that for thick films the diffusion coefficient is consistent with bulk values. The authors would like to thank the Gates-Cambridge Trust and the International Copper Association.
Regulation of NF-κB oscillation by spatial parameters in true intracellular space (TiCS)
NASA Astrophysics Data System (ADS)
Ohshima, Daisuke; Sagara, Hiroshi; Ichikawa, Kazuhisa
2013-10-01
Transcription factor NF-κB is activated by cytokine stimulation, viral infection, or hypoxic environment leading to its translocation to the nucleus. The nuclear NF-κB is exported from the nucleus to the cytoplasm again, and by repetitive import and export, NF-κB shows damped oscillation with the period of 1.5-2.0 h. Oscillation pattern of NF-κB is thought to determine the gene expression profile. We published a report on a computational simulation for the oscillation of nuclear NF-κB in a 3D spherical cell, and showed the importance of spatial parameters such as diffusion coefficient and locus of translation for determining the oscillation pattern. Although the value of diffusion coefficient is inherent to protein species, its effective value can be modified by organelle crowding in intracellular space. Here we tested this possibility by computer simulation. The results indicate that the effective value of diffusion coefficient is significantly changed by the organelle crowding, and this alters the oscillation pattern of nuclear NF-κB.
Marino, Patricia; Roché, Henri; Moatti, Jean-Paul
2008-04-01
The benefit of high-dose chemotherapy (HDC) has not been clearly demonstrated. It may offer disease-free survival improvement at the expense of major toxicity and increasing cost. We evaluated the trade-offs between toxicity, relapse, and costs using a quality-adjusted time without symptoms or toxicity (Q-TWiST) analysis. The analysis was conducted in the context of a randomized trial (PEGASE 01) evaluating the benefit of HDC for 314 patients with high-risk breast cancer. A Q-TWiST analysis was first performed to compare HDC with standard chemotherapy. We then used the results of this Q-TWiST analysis to inform a cost per quality-adjusted life-year (QALY) comparison between treatments. Q-TWiST durations were in favor of HDC, whatever the weighting coefficients used for the analysis. This benefit was significant when the weighting coefficient related to the time spent after relapse was low (<0.38). For quite high values of this coefficient (>0.78), HDC offered no benefit. For intermediate values, the results depended on the weighting coefficient attributed to the toxicity period. The incremental cost per QALY ranged from 12,691euro/QALY to 26,439euro/QALY, according to the coefficients used to weight toxicity and relapse. The benefits of HDC outweigh the burdens of treatment for a wide range of utility coefficients. Economic impact is not a barrier to HDC diffusion in this situation. Nevertheless, no significant benefit was demonstrated for a certain range of utility values.
Can diffusion-weighted imaging distinguish between benign and malignant pediatric liver tumors?
Caro-Domínguez, Pablo; Gupta, Abha A; Chavhan, Govind B
2018-01-01
There are limited data on utility of diffusion-weighted imaging (DWI) in the evaluation of pediatric liver lesions. To determine whether qualitative and quantitative DWI can be used to differentiate benign and malignant pediatric liver lesions. We retrospectively reviewed MRIs in children with focal liver lesions to qualitatively evaluate lesions noting diffusion restriction, T2 shine-through, increased diffusion, hypointensity on DWI and apparent diffusion coefficient (ADC) maps, and intermediate signal on both, and to measure ADC values. Pathology confirmation or a combination of clinical, laboratory and imaging features, and follow-up was used to determine final diagnosis. We included 112 focal hepatic lesions in 89 children (median age 11.5 years, 51 female), of which 92 lesions were benign and 20 malignant. Interobserver agreement was almost perfect for both qualitative (kappa 0.8735) and quantitative (intraclass correlation coefficient [ICC] 0.96) diffusion assessment. All malignant lesions showed diffusion restriction. Most benign lesions other than abscesses were not restricted. There was significant association of qualitative restriction with malignancy and non-restriction with benignancy (Fisher exact test P<0.0001). Mean normalized ADC values of malignant lesions (1.23x10 -3 mm 2 /s) were lower than benign lesions (1.62x10 -3 mm 2 /s; Student's t-test, P<0.015). However, there was significant overlap of ADC between benign and malignant lesions, with wide range for each diagnosis. Receiver operating characteristic (ROC) analysis revealed an area under the curve (AUC) of 0.63 for predicting malignancy using an ADC cut-off value of ≤1.20x10 -3 mm 2 /s, yielding a sensitivity of 78% and a specificity of 54% for differentiating malignant from benign lesions. Qualitative diffusion restriction in pediatric liver lesions is a good predictor of malignancy and can help to differentiate between benign and malignant lesions, in conjunction with conventional MR sequences. Even though malignant lesions demonstrated significantly lower ADC values than benign lesions, the use of quantitative diffusion remains limited in its utility for distinguishing them because of the significant overlap and wide ranges of ADC values.
Photopolymer holographic recording material
NASA Astrophysics Data System (ADS)
Lawrence, J. R.; O'Neill, F. T.; Sheridan, J. T.
Photopolymers are promising materials for use in holography. They have many advantages, such as ease of preparation, and are capable of efficiencies of up to 100%. A disadvantage of these materials is their inability to record high spatial frequency gratings when compared to other materials such as dichromated gelatin and silver halide photographic emulsion. Until recently, the drop off at high spatial frequencies of the material response was not predicted by any of the diffusion based models available. It has recently been proposed that this effect is due to polymer chains growing away from their initiation point and causing a smeared profile to be recorded. This is termed a non-local material response. Simple analytic expressions have been derived using this model and fits to experimental data have allowed values to be estimated for material parameters such as the diffusion coefficient of monomer, the ratio of polymerisation rate to diffusion rate and the distance that the polymer chains spread during holographic recording. The model predicts that the spatial frequency response might be improved by decreasing the mean polymer chain lengths and/or by increasing the mobility of the molecules used in the material. The experimental work carried out to investigate these predictions is reported here. This work involved (a) the changing of the molecular weights of chemical components within the material (dyes and binders) and (b) the addition of a chemical retarder in order to shorten the polymer chains, thereby decreasing the extent of the non-local effect. Although no significant improvement in spatial frequency response was observed the model appears to offer an improved understanding of the operation of the material.
Apparent diffusion coefficient of the normal human brain for various experimental conditions
NASA Astrophysics Data System (ADS)
Moraru, Luminita; Dimitrievici, Lucian
2017-01-01
Diffusion-Weighted Magnetic Resonance Imaging (DW-MRI) is being increasingly used to assess both brain tissues and cerebrospinal fluid integrity. In this paper we study inter-site reproducibility of the apparent diffusion coefficient values for the main cerebral tissues such as gray matter, white matter and into cerebrospinal fluid and for three different stacks of slices that were spaced at L = 79.8, 84.9 and 90 mm. We assessed the impact of the attenuation factor and diffusion gradient on the results reproducibility.
NASA Astrophysics Data System (ADS)
Cao, Jianbo; An, Hengqing; Huang, Xinglu; Fu, Guifeng; Zhuang, Rongqiang; Zhu, Lei; Xie, Jin; Zhang, Fan
2016-05-01
Photothermal therapy (PTT) and photodynamic therapy (PDT) are promising cancer treatment modalities. Because each modality has its own set of advantages and limitations, there has been interest in developing methods that can co-deliver the two regimens for enhanced tumor treatment. Among the efforts, nano-graphene oxide-mediated phototherapies have recently attracted much attention. Nano-graphene oxide has a broad absorbance spectrum and can be loaded with photosensitizers, such as chlorin e6, with high efficiency. Chlorin e6-loaded and PEGylated nano-graphene (GO-PEG-Ce6) can be excited at 660 nm, 808 nm, or both, to induce PDT, PTT, or PDT/PTT combination. Despite the potential of the treatments, there is a lack of a diagnostic tool which can monitor their therapeutic response in a non-invasive and prognostic manner; such an ability is urgently needed for the transformation and translation of the technologies. In this study, we performed diffusion-weighted and blood oxygenation level dependent (BOLD) magnetic resonance imaging (MRI) after GO-PEG-Ce6-mediated PTT, PDT, or PTT/PDT. We found that after efficient PTT, there is a significant increase of the tumor apparent diffusion coefficient (ADC) value in diffusion-weighted imaging (DWI) maps; meanwhile, an efficient PDT led to an increase of in BOLD images. In both the cases, the amplitude of the increase was correlated with the treatment outcomes. More interestingly, a synergistic treatment efficacy was observed when the PTT/PDT combination was applied, and the combination was associated with a greater ADC and increase than when either modality was used alone. In particular, the PTT/PDT condition that induced the most dramatic short-term increase of the ADC value (>70%) caused the most effective tumor control in the long-run, with 60% of the treated animals being tumor-free after 60 days. These results suggest the great promise of the combination of DWI and BOLD MRI as a tool for accurate monitoring and prognosis of phototherapies, which is of great value to the future developments of the methodologies.
2013-01-01
Background An in-vitro setup was established in order to determine a) the diffusion activities of eight otic preparations (Aurizon®, Eas Otic®, Epi Otic®, Otifree®, Otomax®, Panolog®, Posatex®, Surolan®) through synthetic cerumen, and b) the ceruminolytic capacity and impregnation effects of these products. The main lipid classes of canine cerumen produced with moderate, non-purulent otitis externa were determined by thin layer chromatography and were subsequently used to produce a standardised synthetic cerumen (SCC). SCC was filled into capillary tubes, all of which were loaded with six commercially available multipurpose otic medications and two ear cleaners, each mixed with two markers in two experimental setups. These two marker compounds (Oil red O and marbofloxacin) were chosen, since they exhibit different physicochemical drug characteristics by which it is possible to determine and verify the diffusion activity of different types of liquids (i.e. the otic preparations). A synthetic cerumen described in the literature (JSL) was also used for comparison as its lipid composition was different to SCC. The diffusion activities of the otic preparations through both types of synthetic cerumen were studied over 24 hours. A second in-vitro experiment determined both the ceruminolytic activity and impregnation effect of the otic preparations by comparing the weight loss or weight gain after repeated incubation of JSL. Results Canine cerumen is mainly composed of triglycerides, sterol esters, fatty acid esters and squalene. The diffusion experiments showed a high diffusion efficacy along with a high impregnation effect for one test product. All the other products exhibited a lower diffusion activity with a mild to moderate impregnation effect. A mild ceruminolytic activity was observed for the two ear cleaners but not for any of the otic medications. Conclusions The present study demonstrates that there are significant differences in the diffusion characteristics and ceruminolytic properties of the eight tested otic preparations. PMID:23574753
Son, Seung-Myoung; Ha, Sang-Yun; Yoo, Hae-Yong; Oh, Dongryul; Kim, Seok-Jin; Kim, Won-Seog; Ko, Young-Hyeh
2017-01-01
The prognostic role of MYC has been well documented in non-central nervous system diffuse large B-cell lymphoma; however, it remains controversial in central nervous system diffuse large B-cell lymphoma. To investigate the prognostic value of MYC, we analyzed the MYC protein expression by immunohistochemistry, mRNA expression by RNA in situ hybridization, and gene status by fluorescence in situ hybridization in 74 cases of central nervous system diffuse large B-cell lymphoma. Moreover, we examined the correlation between MYC translocation, mRNA expression, and protein expression. The mean percentage of MYC immunopositive cells was 49%. Using a 44% cutoff value, 49 (66%) cases showed MYC protein overexpression. The result of mRNA in situ hybridization using the RNA scope technology was obtained using the H-scoring system; the median value was 34.2. Using the cutoff value of 63.5, 16 (22%) cases showed MYC mRNA overexpression. MYC gene rearrangement was detected in five out of 68 (7%) cases. MYC translocation showed no statistically significant correlation with mRNA expression; however, all MYC translocation-positive cases showed MYC protein overexpression, with a higher mean percentage of MYC protein expression than that of translocation-negative cases (78 vs 48%, P=0.001). The level of MYC mRNA expression was moderately correlated with the level of MYC protein expression (P<0.001). The mean percentage of MYC protein expression in the high MYC mRNA group was higher than that in the low MYC mRNA group (70 vs 47%, P<0.001). A univariate analysis showed that age over 60 years, Eastern Cooperative Oncology Group (ECOG) performance status ≥2 and MYC protein overexpression were significantly associated with an increased risk of death. MYC translocation and MYC mRNA expression had no prognostic significance. On multivariate analysis, MYC protein overexpression and ECOG score retained prognostic significance.
Diffusion kurtosis imaging for differentiating between the benign and malignant sinonasal lesions.
Jiang, Jing Xuan; Tang, Zuo Hua; Zhong, Yu Feng; Qiang, Jin Wei
2017-05-01
The study aimed to evaluate diffusion kurtosis imaging (DKI) in the differentiation between benign and malignant sinonasal lesions, and to compare the diagnostic performance of DKI with diffusion weighted imaging (DWI). Eight-one patients with solid sinonasal lesions confirmed by surgery and pathology (46 malignant and 35 benign) underwent conventional MRI, DWI, and DKI. DKI was performed employing a 13 extended b-value ranging from 0 to 2500 s/mm 2 . Apparent diffusion coefficient (ADC) from DWI, kurtosis (K), and diffusion coefficient (D) from DKI were measured and compared between two groups. ADC and D values were significantly lower in the malignant sinonasal lesions than in the benign sinonasal lesions (1.11 ± 0.41 versus 1.58 ± 0.50 × 10 -3 mm 2 /s and 1.45 ± 0.36 versus 2.03 ± 0.49 × 10 -3 mm 2 /s, respectively, both P < 0001). K value was significantly higher in the malignant lesions than in the benign lesions (0.91 ± 0.23 versus 0.57 ± 0.24, P < 0001). The receiver operating characteristic curve analyses yielded a cutoff ADC value of 1.27 × 10 -3 mm 2 /s for differentiating between benign and malignant lesions, with a sensitivity of 69.6%, a specificity of 77.1% and an accuracy of 74.0%; a cutoff D value of 1.75 × 10 -3 mm 2 /s, with a sensitivity of 82.6%, a specificity of 77.1% and an accuracy of 80.2%; a cutoff K value of 0.63 with a sensitivity of 95.7%, a specificity of 77.1% and an accuracy of 87.7%. The area under the curve of K value was significantly larger than that of ADC value (0.875 versus 0.762; P < 0.05). K value of DKI demonstrates significantly higher accuracy compared with ADC value for the differentiation between benign and malignant sinonasal lesions. DKI may be a noninvasive method to evaluate the sinonasal lesions. 1 J. MAGN. RESON. IMAGING 2017;45:1446-1454. © 2016 International Society for Magnetic Resonance in Medicine.
Choi, Moon Hyung; Oh, Soon Nam; Rha, Sung Eun; Choi, Joon-Il; Lee, Sung Hak; Jang, Hong Seok; Kim, Jun-Gi; Grimm, Robert; Son, Yohan
2016-07-01
To investigate the usefulness of apparent diffusion coefficient (ADC) values derived from histogram analysis of the whole rectal cancer as a quantitative parameter to evaluate pathologic complete response (pCR) on preoperative magnetic resonance imaging (MRI). We enrolled a total of 86 consecutive patients who had undergone surgery for rectal cancer after neoadjuvant chemoradiotherapy (CRT) at our institution between July 2012 and November 2014. Two radiologists who were blinded to the final pathological results reviewed post-CRT MRI to evaluate tumor stage. Quantitative image analysis was performed using T2 -weighted and diffusion-weighted images independently by two radiologists using dedicated software that performed histogram analysis to assess the distribution of ADC in the whole tumor. After surgery, 16 patients were confirmed to have achieved pCR (18.6%). All parameters from pre- and post-CRT ADC histogram showed good or excellent agreement between two readers. The minimum, 10th, 25th, 50th, and 75th percentile and mean ADC from post-CRT ADC histogram were significantly higher in the pCR group than in the non-pCR group for both readers. The 25th percentile value from ADC histogram in post-CRT MRI had the best diagnostic performance for detecting pCR, with an area under the receiver operating characteristic curve of 0.796. Low percentile values derived from the ADC histogram analysis of rectal cancer on MRI after CRT showed a significant difference between pCR and non-pCR groups, demonstrating the utility of the ADC value as a quantitative and objective marker to evaluate complete pathologic response to preoperative CRT in rectal cancer. J. Magn. Reson. Imaging 2016;44:212-220. © 2015 Wiley Periodicals, Inc.
Compromised Integrity of Central Visual Pathways in Patients With Macular Degeneration.
Malania, Maka; Konrad, Julia; Jägle, Herbert; Werner, John S; Greenlee, Mark W
2017-06-01
Macular degeneration (MD) affects the central retina and leads to gradual loss of foveal vision. Although, photoreceptors are primarily affected in MD, the retinal nerve fiber layer (RNFL) and central visual pathways may also be altered subsequent to photoreceptor degeneration. Here we investigate whether retinal damage caused by MD alters microstructural properties of visual pathways using diffusion-weighted magnetic resonance imaging. Six MD patients and six healthy control subjects participated in the study. Retinal images were obtained by spectral-domain optical coherence tomography (SD-OCT). Diffusion tensor images (DTI) and high-resolution T1-weighted structural images were collected for each subject. We used diffusion-based tensor modeling and probabilistic fiber tractography to identify the optic tract (OT) and optic radiations (OR), as well as nonvisual pathways (corticospinal tract and anterior fibers of corpus callosum). Fractional anisotropy (FA) and axial and radial diffusivity values (AD, RD) were calculated along the nonvisual and visual pathways. Measurement of RNFL thickness reveals that the temporal circumpapillary retinal nerve fiber layer was significantly thinner in eyes with macular degeneration than normal. While we did not find significant differences in diffusion properties in nonvisual pathways, patients showed significant changes in diffusion scalars (FA, RD, and AD) both in OT and OR. The results indicate that the RNFL and the white matter of the visual pathways are significantly altered in MD patients. Damage to the photoreceptors in MD leads to atrophy of the ganglion cell axons and to corresponding changes in microstructural properties of central visual pathways.
Regier, M; Derlin, T; Schwarz, D; Laqmani, A; Henes, F O; Groth, M; Buhk, J-H; Kooijman, H; Adam, G
2012-10-01
To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm(2)) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV(mean)) and maximum (SUV(max)) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC(mean)) and minimum ADC (ADC(min)) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland-Altman and regression analysis were assessed. Data analysis revealed a significant inverse correlation of the ADC(min) and SUV(max) (r=-0.46; p=0.032). Testing the correlation of the ADC(min) and SUV(max) for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r=-0.47; p=0.03) and squamouscell carcinomas (r=-0.71; p=0.002), respectively. No significant correlation was found for the comparison of ADC(min) and SUV(mean) (r=-0.29; p=0.27), ADC(mean) vs. SUV(mean) (r=-0.28; p=0.31) or ADC(mean) vs. SUV(max) (r=-0.33; p=0.23). The κ-value of 0.88 indicated a good agreement between both observers. This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Hardie, Andrew D; Egbert, Robert E; Rissing, Michael S
2015-01-01
Diffusion-weighted magnetic resonance imaging (DW-MR) can be useful in the differentiation of hemangiomata from liver metastasis, but improved methods other than by mean apparent diffusion coefficient (mADC) are needed. A retrospective review identified 109 metastatic liver lesions and 86 hemangiomata in 128 patients who had undergone DW-MR. For each lesion, mADC and the standard deviation of the mean ADC (sdADC) were recorded and compared by receiver operating characteristic analysis. Mean mADC was higher in benign hemangiomata (1.52±0.12 mm(2)/s) than in liver metastases (1.33±0.18 mm(2)/s), but there was significant overlap in values. The mean sdADC was lower in hemangiomata (101±17 mm(2)/s) than metastases (245±25 mm(2)/s) and demonstrated no overlap in values, which was significantly different (P<.0001). Hemangiomata may be better able to be differentiated from liver metastases on the basis of sdADC than by mADC, although further studies are needed. Copyright © 2015 Elsevier Inc. All rights reserved.
Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael; Boudiaf, Mourad; Hoeffel, Christine; Soyer, Philippe
2015-08-01
To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n=17; intrahepatic, n=11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800s/mm(2)). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P<0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042×10(-3)mm(2)/s±0.221×10(-3)mm(2)/s; range: 0.616×10(-3)mm(2)/s to 2.050×10(-3)mm(2)/s) was significantly lower than that of apparently normal hepatic parenchyma (1.362×10(-3)mm(2)/s±0.187×10(-3)mm(2)/s) (P<0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation coefficient=16.6%). There is a trend towards a common appearance of intrahepatic and hilar mass-forming cholangiocarcinomas on DW-MRI but variations may be observed. Familiarity with these variations may improve the diagnosis of mass-forming cholangiocarcinoma. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Herek, Duygu; Karabulut, Nevzat; Kocyıgıt, Ali; Yagcı, Ahmet Baki
2016-01-01
Our aim was to compare the apparent diffusion coefficient (ADC) values of normal abdominal parenchymal organs and signal-to-noise ratio (SNR) measurements in the same patients with breath hold (BH) and free breathing (FB) diffusion weighted imaging (DWI). Forty-eight patients underwent both BH and FB DWI. Spherical region of interest (ROI) was placed on the right hepatic lobe, spleen, pancreas, and renal cortices. ADC values were calculated for each organ on each sequence using an automated software. Image noise, defined as the standard deviation (SD) of the signal intensities in the most artifact-free area of the image background was measured by placing the largest possible ROI on either the left or the right side of the body outside the object in the recorded field of view. SNR was calculated using the formula: SNR=signal intensity (SI) (organ) /standard deviation (SD) (noise) . There were no statistically significant differences in ADC values of the abdominal organs between BH and FB DWI sequences ( p >0.05). There were statistically significant differences between SNR values of organs on BH and FB DWIs. SNRs were found to be better on FB DWI than BH DWI ( p <0.001). Free breathing DWI technique reduces image noise and increases SNR for abdominal examinations. Free breathing technique is therefore preferable to BH DWI in the evaluation of abdominal organs by DWI.
Idiopathic granulomatous mastitis: magnetic resonance imaging findings with diffusion MRI.
Aslan, Hulya; Pourbagher, Aysin; Colakoglu, Tamer
2016-07-01
Idiopathic granulomatous mastitis (IGM) is a rare benign breast disease with unknown etiology which can mimic breast carcinoma, both clinically and radiologically. Magnetic resonance imaging (MRI) findings of IGM have been previously described; however there is no study evaluating diffusion-weighted MRI findings of IGM. To analyze conventional, dynamic contrast-enhanced, and diffusion-weighted MRI signal characteristics of IGM by comparing it with the contralateral normal breast parenchyma. A total of 39 patients were included in the study. On dynamic contrast-enhanced MRI, the distribution and enhancement patterns of the lesions were evaluated. We also detected the frequencies of involving quadrants, retroareolar involvement, accompanying abscess, and skin edema. T2-weighted (T2W) and STIR signal intensities and both mean and minimum apparent diffusion coefficient (ADC) values were compared with the contralateral normal parenchyma. IGM showed significantly lower mean and minimum ADC values when compared with the normal parenchyma. Signal intensities on T2W and STIR sequences of the lesion were significantly higher than the normal parenchyma. On dynamic contrast-enhanced MRI, 7.7% of the patients had mass-like contrast enhancement, 92.3% of the patients had non-mass-like contrast enhancement. Abscess was positive in 33.3% of the patients. As a result, IGM showed commonly non-mass-like lesions with restricted diffusion. Although it is a benign pathology, it may show clustered ring-like enhancement like malignant lesions. © The Foundation Acta Radiologica 2015.
Assessment of the Focal Hepatic Lesions Using Diffusion Tensor Magnetic Resonance Imaging
Oussous, Siham Ait; Boujraf, Saïd; Kamaoui, Imane
2016-01-01
The goal is assessing the diffusion magnetic resonance imaging (dMRI) method efficiency in characterizing focal hepatic lesions (FHLs). About 28-FHL patients were studied in Radiology and Clinical Imaging Department of our University Hospital using 1.5 Tesla MRI system between January 2010 and June 2011. Patients underwent hepatic MRI consisting of dynamic T1- and T2-weighted imaging. The dMRI was performed with b-values of 200 s/mm2 and 600 s/mm2. About 42 lesions measuring more than 1 cm were studied including the variation of the signal according to the b-value and the apparent diffusion coefficient (ADC). The diagnostic imaging reference was based on standard MRI techniques data for typical lesions and on histology after surgical biopsy for atypical lesions. About 38 lesions were assessed including 13 benign lesions consisting of 1 focal nodular hyperplasia, 8 angiomas, and 4 cysts. About 25 malignant lesions included 11 hepatocellular carcinoma, 9 hepatic metastases, 1 cholangiocarcinoma, and 4 lymphomas. dMRI of soft lesions demonstrated higher ADC of 2.26 ± 0.75 mm2/s, whereas solid lesions showed lower ADC 1.19 ± 0.33 mm2/s with significant difference (P = 0.05). Discrete values collections were noticed. These results were correlated to standard MRI and histological findings. Sensitivity of 93% and specificity of 84% were found in diagnoses of malignant tumors with an ADC threshold of 1.6 × 10−3 mm2/s. dMRI is important characterization method of FHL. However, it should not be used as single criteria of hepatic lesions malignity. MRI, clinical, and biological data must be correlated. Significant difference was found between benign and solid malignant lesions without threshold ADC values. Hence, it is difficult to confirm ADC threshold differentiating the lesion classification. PMID:27186537
Nakajo, Masanori; Fukukura, Yoshihiko; Hakamada, Hiroto; Yoneyama, Tomohide; Kamimura, Kiyohisa; Nagano, Satoshi; Nakajo, Masayuki; Yoshiura, Takashi
2018-02-22
Apparent diffusion coefficient (ADC) histogram analyses have been used to differentiate tumor grades and predict therapeutic responses in various anatomic sites with moderate success. To determine the ability of diffusion-weighted imaging (DWI) with a whole-tumor ADC histogram analysis to differentiate benign peripheral neurogenic tumors (BPNTs) from soft tissue sarcomas (STSs). Retrospective study, single institution. In all, 25 BPNTs and 31 STSs. Two-b value DWI (b-values = 0, 1000s/mm 2 ) was at 3.0T. The histogram parameters of whole-tumor for ADC were calculated by two radiologists and compared between BPNTs and STSs. Nonparametric tests were performed for comparisons between BPNTs and STSs. P < 0.05 was considered statistically significant. The ability of each parameter to differentiate STSs from BPNTs was evaluated using area under the curve (AUC) values derived from a receiver operating characteristic curve analysis. The mean ADC and all percentile parameters were significantly lower in STSs than in BPNTs (P < 0.001-0.009), with AUCs of 0.703-0.773. However, the coefficient of variation (P = 0.020 and AUC = 0.682) and skewness (P = 0.012 and AUC = 0.697) were significantly higher in STSs than in BPNTs. Kurtosis (P = 0.295) and entropy (P = 0.604) did not differ significantly between BPNTs and STSs. Whole-tumor ADC histogram parameters except kurtosis and entropy differed significantly between BPNTs and STSs. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Lundell, Henrik; Alexander, Daniel C; Dyrby, Tim B
2014-08-01
Stimulated echo acquisition mode (STEAM) diffusion MRI can be advantageous over pulsed-gradient spin-echo (PGSE) for diffusion times that are long compared with T2 . It therefore has potential for biomedical diffusion imaging applications at 7T and above where T2 is short. However, gradient pulses other than the diffusion gradients in the STEAM sequence contribute much greater diffusion weighting than in PGSE and lead to a disrupted experimental design. Here, we introduce a simple compensation to the STEAM acquisition that avoids the orientational bias and disrupted experiment design that these gradient pulses can otherwise produce. The compensation is simple to implement by adjusting the gradient vectors in the diffusion pulses of the STEAM sequence, so that the net effective gradient vector including contributions from diffusion and other gradient pulses is as the experiment intends. High angular resolution diffusion imaging (HARDI) data were acquired with and without the proposed compensation. The data were processed to derive standard diffusion tensor imaging (DTI) maps, which highlight the need for the compensation. Ignoring the other gradient pulses, a bias in DTI parameters from STEAM acquisition is found, due both to confounds in the analysis and the experiment design. Retrospectively correcting the analysis with a calculation of the full B matrix can partly correct for these confounds, but an acquisition that is compensated as proposed is needed to remove the effect entirely. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.
Sagiyama, Koji; Watanabe, Yuji; Kamei, Ryotaro; Hong, Sungtak; Kawanami, Satoshi; Matsumoto, Yoshihiro; Honda, Hiroshi
2017-12-01
To investigate the usefulness of voxel-based analysis of standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs) for evaluating soft-tissue tumour malignancy with a PET/MR system. Thirty-five subjects with either ten low/intermediate-grade tumours or 25 high-grade tumours were prospectively enrolled. Zoomed diffusion-weighted and fluorodeoxyglucose ( 18 FDG)-PET images were acquired along with fat-suppressed T2-weighted images (FST2WIs). Regions of interest (ROIs) were drawn on FST2WIs including the tumour in all slices. ROIs were pasted onto PET and ADC-maps to measure SUVs and ADCs within tumour ROIs. Tumour volume, SUVmax, ADCminimum, the heterogeneity and the correlation coefficients of SUV and ADC were recorded. The parameters of high- and low/intermediate-grade groups were compared, and receiver operating characteristic (ROC) analysis was also performed. The mean correlation coefficient for SUV and ADC in high-grade sarcomas was lower than that of low/intermediate-grade tumours (-0.41 ± 0.25 vs. -0.08 ± 0.34, P < 0.01). Other parameters did not differ significantly. ROC analysis demonstrated that correlation coefficient showed the best diagnostic performance for differentiating the two groups (AUC 0.79, sensitivity 96.0%, specificity 60%, accuracy 85.7%). SUV and ADC determined via PET/MR may be useful for differentiating between high-grade and low/intermediate-grade soft tissue tumours. • PET/MR allows voxel-based comparison of SUVs and ADCs in soft-tissue tumours. • A comprehensive assessment of internal heterogeneity was performed with scatter plots. • SUVmax or ADCminimum could not differentiate high-grade sarcoma from low/intermediate-grade tumours. • Only the correlation coefficient between SUV and ADC differentiated the two groups. • The correlation coefficient showed the best diagnostic performance by ROC analysis.
Wang, Feng; Wang, Yuxiang; Zhou, Yan; Liu, Congrong; Xie, Lizhi; Zhou, Zhenyu; Liang, Dong; Shen, Yang; Yao, Zhihang; Liu, Jianyu
2017-12-01
To evaluate the utility of histogram analysis of monoexponential, biexponential, and stretched-exponential models to a dualistic model of epithelial ovarian cancer (EOC). Fifty-two patients with histopathologically proven EOC underwent preoperative magnetic resonance imaging (MRI) (including diffusion-weighted imaging [DWI] with 11 b-values) using a 3.0T system and were divided into two groups: types I and II. Apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), distributed diffusion coefficient (DDC), and intravoxel water diffusion heterogeneity (α) histograms were obtained based on solid components of the entire tumor. The following metrics of each histogram were compared between two types: 1) mean; 2) median; 3) 10th percentile and 90th percentile. Conventional MRI morphological features were also recorded. Significant morphological features for predicting EOC type were maximum diameter (P = 0.007), texture of lesion (P = 0.001), and peritoneal implants (P = 0.001). For ADC, D, f, DDC, and α, all metrics were significantly lower in type II than type I (P < 0.05). Mean, median, 10th, and 90th percentile of D* were not significantly different (P = 0.336, 0.154, 0.779, and 0.203, respectively). Most histogram metrics of ADC, D, and DDC had significantly higher area under the receiver operating characteristic curve values than those of f and α (P < 0.05) CONCLUSION: It is feasible to grade EOC by morphological features and three models with histogram analysis. ADC, D, and DDC have better performance than f and α; f and α may provide additional information. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1797-1809. © 2017 International Society for Magnetic Resonance in Medicine.
Diffusion of chains in a periodic potential
NASA Astrophysics Data System (ADS)
Terranova, G. R.; Mártin, H. O.; Aldao, C. M.
2017-09-01
We studied the diffusion of 1D rigid chains in a square wave potential of period T. We considered chains of type A (composed of N particles A) and chains of type A-B (composed of N/2 particles A and N/2 particles B). The square wave potential represents domains, a lamellar structure observed for block copolymers, in which the repulsive δ energy between each A particle (B particle) of the chain and B particles (A particles) of the medium where the chains diffuse. From Monte Carlo simulations and analytical results it is found that the normalized diffusivity D, for N\\ll T , presents a universal behavior as a function of X = Nδ for chains of type A and X = (Nδ - lnT 2) for chains of type A-B, with and exponential decay for large values of X. For fixed values of δ and T, D is a periodic function of N with period T and 2T for chains of type A and type A-B, respectively.
Aye, Tandy; Barnea-Goraly, Naama; Ambler, Christian; Hoang, Sherry; Schleifer, Kristin; Park, Yaena; Drobny, Jessica; Wilson, Darrell M.; Reiss, Allan L.; Buckingham, Bruce A.
2012-01-01
OBJECTIVE To detect clinical correlates of cognitive abilities and white matter (WM) microstructural changes using diffusion tensor imaging (DTI) in young children with type 1 diabetes. RESEARCH DESIGN AND METHODS Children, ages 3 to <10 years, with type 1 diabetes (n = 22) and age- and sex-matched healthy control subjects (n = 14) completed neurocognitive testing and DTI scans. RESULTS Compared with healthy controls, children with type 1 diabetes had lower axial diffusivity (AD) values (P = 0.046) in the temporal and parietal lobe regions. There were no significant differences between groups in fractional anisotropy and radial diffusivity (RD). Within the diabetes group, there was a significant, positive correlation between time-weighted HbA1c and RD (P = 0.028). A higher, time-weighted HbA1c value was significantly correlated with lower overall intellectual functioning measured by the full-scale intelligence quotient (P = 0.03). CONCLUSIONS Children with type 1 diabetes had significantly different WM structure (as measured by AD) when compared with controls. In addition, WM structural differences (as measured by RD) were significantly correlated with their HbA1c values. Additional studies are needed to determine if WM microstructural differences in young children with type 1 diabetes predict future neurocognitive outcome. PMID:22966090
Interfacial diffusion aided deformation during nanoindentation
Samanta, Amit; E., Weinan
2015-07-06
Nanoindentation is commonly used to quantify the mechanical response of material surfaces. Despite its widespread use, a detailed understanding of the deformation mechanisms responsible for plasticity during these experiments has remained elusive. Nanoindentation measurements often show stress values close to a material’s ideal strength which suggests that dislocation nucleation and subsequent dislocation activity dominates the deformation. However, low strain-rate exponents and small activation volumes have also been reported which indicates high temperature sensitivity of the deformation processes. Using an order parameter aided temperature accelerated sampling technique called adiabatic free energy dynamics [J. B. Abrams and M. E. Tuckerman, J. Phys.more » Chem. B, 112, 15742 (2008)], and molecular dynamics we have probed the diffusive mode of deformation during nanoindentation. Localized processes such as surface vacancy and ad-atom pair formation, vacancy diffusion are found to play an important role during indentation. Furthermore, our analysis suggests a change in the dominant deformation mode from dislocation mediated plasticity to diffusional flow at high temperatures, slow indentation rates and small indenter tip radii.« less
Yoshimura, Hajime; Matsumoto, Riki; Ueda, Hiroyuki; Ariyoshi, Koichi; Kawamoto, Michi; Ishii, Junko; Ikeda, Akio; Takahashi, Ryosuke; Kohara, Nobuo
2016-11-15
To delineate the clinical characteristics and functional outcome of status epilepticus (SE) in elderly people, and elucidate prognostic implications of SE-associated rhythmic and periodic patterns (RPPs) in electroencephalography and hyperintensities on diffusion-weighted imaging. We retrospectively investigated 107 consecutive patients with SE aged≥65years in a comprehensive community hospital. RPPs were classified using the 2012 American Clinical Neurophysiology Society's Standardized Critical Care EEG Terminology. Poor outcome was defined as an increase in modified Rankin Scale (mRS) score at discharge compared with that at baseline, including death. Median age of patients was 80.0years. Median mRS score at baseline was 3. Thirty-four patients (31.8%) had a previous diagnosis of epilepsy. Cerebrovascular disease and dementia were major etiologies. Poor outcome occurred in 41 (38.3%). In electroencephalography, periodic discharges (PDs) were present in 21.0% (22/105), rhythmic delta activity (RDA) in 10.5% (11/105), and conventional seizure patterns in 9.5% (10/105). Diffusion-weighted hyperintensities associated with SE were observed in 28.0% (26/93). With univariate analysis, poor outcome was significantly associated with no previous diagnosis of epilepsy, etiology, refractory SE, specific electroencephalographic patterns (PDs and conventional seizure patterns, but not RDA), and diffusion-weighted hyperintensities. With multivariate logistic regression analysis, diffusion-weighted hyperintensities (OR 6.13 [95% CI 1.72-21.9]) and refractory SE (OR 5.36 [95% CI 1.28-22.4]) were independently associated with poor outcome. SE often occurred as the first seizure in already disabled elderly people, further worsening their functional disabilities. Diffusion-weighted hyperintensities and refractory SE, but not RPPs in electroencephalography, were independent functional prognostic factors. Copyright © 2016 Elsevier B.V. All rights reserved.
Melchardt, Thomas; Troppan, Katharina; Weiss, Lukas; Hufnagl, Clemens; Neureiter, Daniel; Tränkenschuh, Wolfgang; Schlick, Konstantin; Huemer, Florian; Deutsch, Alexander; Neumeister, Peter; Greil, Richard; Pichler, Martin; Egle, Alexander
2015-12-01
Several serum parameters have been evaluated for adding prognostic value to clinical scoring systems in diffuse large B-cell lymphoma (DLBCL), but none of the reports used multivariate testing of more than one parameter at a time. The goal of this study was to validate widely available serum parameters for their independent prognostic impact in the era of the National Comprehensive Cancer Network-International Prognostic Index (NCCN-IPI) score to determine which were the most useful. This retrospective bicenter analysis includes 515 unselected patients with DLBCL who were treated with rituximab and anthracycline-based chemoimmunotherapy between 2004 and January 2014. Anemia, high C-reactive protein, and high bilirubin levels had an independent prognostic value for survival in multivariate analyses in addition to the NCCN-IPI, whereas neutrophil-to-lymphocyte ratio, high gamma-glutamyl transferase levels, and platelets-to-lymphocyte ratio did not. In our cohort, we describe the most promising markers to improve the NCCN-IPI. Anemia and high C-reactive protein levels retain their power in multivariate testing even in the era of the NCCN-IPI. The negative role of high bilirubin levels may be associated as a marker of liver function. Further studies are warranted to incorporate these markers into prognostic models and define their role opposite novel molecular markers. Copyright © 2015 by the National Comprehensive Cancer Network.
Maltez de Almeida, João Ricardo; Gomes, André Boechat; Barros, Thomas Pitangueira; Fahel, Paulo Eduardo; de Seixas Rocha, Mário
2015-07-01
The purposes of this study were to investigate whether dynamic contrast-enhanced MRI is adequate for subcategorization of suspicious lesions (BI-RADS category 4) and to evaluate whether use of DWI improves diagnostic performance. The study group was composed of 103 suspicious lesions found in 83 subjects. Patient ages and lesion sizes were compiled, and two radiologists reanalyzed the images; subcategorized the findings as BI-RADS 4A, 4B, or 4C; and calculated apparent diffusion coefficient (ADC) values. The stratified variables were tested by univariate analysis and inserted in two multivariate predictive models, which were used to generate ROC curves and compare AUCs. Positive predictive values (PPVs) for each subcategory and ADC level were calculated, and interobserver agreement was tested. Forty-four (42.7%) suspicious findings proved malignant. Except for age (p = 0.08), all stratified predictor variables were significant in univariate analyses (p < 0.01). Logistic regression models did not differ substantially after comparison of the ROC curves (p = 0.09), but the one including ADC values was slightly better: AUC of 0.89 (95% CI, 0.82-0.95) against AUC of 0.85 (95% CI, 0.78-0.93). PPV increased progressively in each BI-RADS 4 subcategory (4A, 0.15; 4B, 0.37; 4C, 0.84). ADC values of 1.10 × 10(-3) mm(2)/s or less had the second highest PPV (0.77). Interobserver agreement was substantial at a kappa value of 0.80 (95% CI, 0.70-0.90; p < 0.01). Risk stratification of suspicious lesions (BI-RADS category 4) can be satisfactorily performed with DCE-MRI and slightly improved when DWI is introduced.
Counsell, Serena J; Shen, Yuji; Boardman, James P; Larkman, David J; Kapellou, Olga; Ward, Philip; Allsop, Joanna M; Cowan, Frances M; Hajnal, Joseph V; Edwards, A David; Rutherford, Mary A
2006-02-01
Diffuse excessive high signal intensity (DEHSI) is observed in the majority of preterm infants at term-equivalent age on conventional MRI, and diffusion-weighted imaging has shown that apparent diffusion coefficient values are elevated in the white matter (WM) in DEHSI. Our aim was to obtain diffusion tensor imaging on preterm infants at term-equivalent age and term control infants to test the hypothesis that radial diffusivity was significantly different in the WM in preterm infants with DEHSI compared with both preterm infants with normal-appearing WM on conventional MRI and term control infants. Diffusion tensor imaging was obtained on 38 preterm infants at term-equivalent age and 8 term control infants. Values for axial (lambda1) and radial [(lambda2 + lambda3)/2] diffusivity were calculated in regions of interest positioned in the central WM at the level of the centrum semiovale, frontal WM, posterior periventricular WM, occipital WM, anterior and posterior portions of the posterior limb of the internal capsule, and the genu and splenium of the corpus callosum. Radial diffusivity was elevated significantly in the posterior portion of the posterior limb of the internal capsule and the splenium of the corpus callosum, and both axial and radial diffusivity were elevated significantly in the WM at the level of the centrum semiovale, the frontal WM, the periventricular WM, and the occipital WM in preterm infants with DEHSI compared with preterm infants with normal-appearing WM and term control infants. There was no significant difference between term control infants and preterm infants with normal-appearing WM in any region studied. These findings suggest that DEHSI represents an oligodendrocyte and/or axonal abnormality that is widespread throughout the cerebral WM.
Hussain, Zainab; Hilal, Kiran; Ahmad, Muhammad; Sajjad, Zafar; Sayani, Raza
2018-03-02
Diffusion-weighted magnetic resonance imaging (DW-MRI) represents a major advance in the early diagnosis of acute ischemic stroke. It can detect edema due to ischemia in the brain tissue. It not only establishes the presence and location of ischemic brain injury but also a relatively new concept is the determination of infarct patterns seen on diffusion imaging and its clinical correlation. Objective To determine the frequency of various infarct patterns and their relationship with functional outcome of the patient. Materials and methods A total of 108 patients with acute stroke were enrolled by purposive sampling. Magnetic resonance imaging (MRI) was obtained with departmental protocol and diffusion-weighted sequences. The clinical data was collected from medical records and functional outcome was assessed at the time of admission using Barthel Index (BI) which was dichotomized into poor and favorable outcomes. The radiological data was collected and three infarct patterns (cortical, subcortical, and territorial infarcts) were recorded from diffusion-weighted images. Association of other risk factors such as age, gender, diabetes, hypertension (HTN), hyperlipidemia, and smoking were also evaluated. Results Amongst the three infarct patterns, subcortical infarcts were noted with the highest proportion of 62% (67/108). The highest proportion of territorial infarcts (78.6%) was significantly associated with a poor outcome in comparison to cortical and subcortical infarcts. Cortical infarcts (61.5%) were significantly associated with good outcomes followed by subcortical and then territorial infarcts (p-value < 0.002). Amongst the risk factors, HTN was found to be highly prevalent followed by diabetes mellitus (DM). Conclusion Subcortical infarct pattern was the most common, followed by territorial and cortical infarct. The highest proportion of infarct pattern with good outcomes was seen with cortical infarcts followed by subcortical and then territorial infarct pattern. HTN and coronary artery disease (CAD) were the effect modifiers showing significant association with poor outcomes.
Diffusion lengths in irradiated N/P InP-on-Si solar cells
NASA Technical Reports Server (NTRS)
Wojtczuk, Steven; Colerico, Claudia; Summers, Geoffrey P.; Walters, Robert J.; Burke, Edward A.
1995-01-01
Indium phosphide (InP) solar cells are being made on silicon (Si) wafers (InP/Si) to take advantage of both the radiation-hardness properties of the InP solar cell and the light weight and low cost of Si wafers compared to InP or germanium (Ge) wafers. The InP/Si cell application is for long duration and/or high radiation orbit space missions. InP/Si cells have higher absolute efficiency after a high radiation dose than gallium arsenide (GaAs) or silicon (Si) solar cells. In this work, base electron diffusion lengths in the N/P cell are extracted from measured AM0 short-circuit photocurrent at various irradiation levels out to an equivalent 1 MeV fluence of 1017 1 MeV electrons/sq cm for a 1 sq cm 12% BOL InP/Si cell. These values are then checked for consistency by comparing measured Voc data with a theoretical Voc model that includes a dark current term that depends on the extracted diffusion lengths.
Dyvorne, Hadrien A.; Galea, Nicola; Nevers, Thomas; Fiel, M. Isabel; Carpenter, David; Wong, Edmund; Orton, Matthew; de Oliveira, Andre; Feiweier, Thorsten; Vachon, Marie-Louise; Babb, James S.
2013-01-01
Purpose: To optimize intravoxel incoherent motion (IVIM) diffusion-weighted (DW) imaging by estimating the effects of diffusion gradient polarity and breathing acquisition scheme on image quality, signal-to-noise ratio (SNR), IVIM parameters, and parameter reproducibility, as well as to investigate the potential of IVIM in the detection of hepatic fibrosis. Materials and Methods: In this institutional review board–approved prospective study, 20 subjects (seven healthy volunteers, 13 patients with hepatitis C virus infection; 14 men, six women; mean age, 46 years) underwent IVIM DW imaging with four sequences: (a) respiratory-triggered (RT) bipolar (BP) sequence, (b) RT monopolar (MP) sequence, (c) free-breathing (FB) BP sequence, and (d) FB MP sequence. Image quality scores were assessed for all sequences. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF) in liver parenchyma. Mixed-model analysis of variance was used to compare image quality, SNR, IVIM parameters, and interexamination variability between the four sequences, as well as the ability to differentiate areas of liver fibrosis from normal liver tissue. Results: Image quality with RT sequences was superior to that with FB acquisitions (P = .02) and was not affected by gradient polarity. SNR did not vary significantly between sequences. IVIM parameter reproducibility was moderate to excellent for PF and D, while it was less reproducible for D*. PF and D were both significantly lower in patients with hepatitis C virus than in healthy volunteers with the RT BP sequence (PF = 13.5% ± 5.3 [standard deviation] vs 9.2% ± 2.5, P = .038; D = [1.16 ± 0.07] × 10−3 mm2/sec vs [1.03 ± 0.1] × 10−3 mm2/sec, P = .006). Conclusion: The RT BP DW imaging sequence had the best results in terms of image quality, reproducibility, and ability to discriminate between healthy and fibrotic liver with biexponential fitting. © RSNA, 2012 PMID:23220895
Bai, Yan; Lin, Yusong; Zhang, Wei; Kong, Lingfei; Wang, Lifu; Zuo, Panli; Vallines, Ignacio; Schmitt, Benjamin; Tian, Jie; Song, Xiaolei; Zhou, Jinyuan; Wang, Meiyun
2017-01-24
Using noninvasive magnetic resonance imaging techniques to accurately evaluate the grading and cellularity of gliomas is beneficial for improving the patient outcomes. Amide proton transfer imaging is a noninvasive molecular magnetic resonance imaging technique based on chemical exchange saturation transfer mechanism that detects endogenous mobile proteins and peptides in biological tissues. Between August 2012 and November 2015, a total number of 44 patients with pathologically proven gliomas were included in this study. We compared the capability of amide proton transfer magnetic resonance imaging with that of noninvasive diffusion-weighted imaging and noninvasive 3-dimensional pseudo-continuous arterial spin imaging in evaluating the grading and cellularity of gliomas. Our results reveal that amide proton transfer magnetic resonance imaging is a superior imaging technique to diffusion-weighted imaging and 3-dimensional pseudo-continuous arterial spin imaging in the grading of gliomas. In addition, our results showed that the Ki-67 index correlated better with the amide proton transfer-weighted signal intensity than with the apparent diffusion coefficient value or the cerebral blood flow value in the gliomas. Amide proton transfer magnetic resonance imaging is a promising method for predicting the grading and cellularity of gliomas.
Takahashi, Masahiro; Kozawa, Eito; Tanisaka, Megumi; Hasegawa, Kousei; Yasuda, Masanori; Sakai, Fumikazu
2016-06-01
We explored the role of histogram analysis of apparent diffusion coefficient (ADC) maps for discriminating uterine carcinosarcoma and endometrial carcinoma. We retrospectively evaluated findings in 13 patients with uterine carcinosarcoma and 50 patients with endometrial carcinoma who underwent diffusion-weighted imaging (b = 0, 500, 1000 s/mm(2) ) at 3T with acquisition of corresponding ADC maps. We derived histogram data from regions of interest drawn on all slices of the ADC maps in which tumor was visualized, excluding areas of necrosis and hemorrhage in the tumor. We used the Mann-Whitney test to evaluate the capacity of histogram parameters (mean ADC value, 5th to 95th percentiles, skewness, kurtosis) to discriminate uterine carcinosarcoma and endometrial carcinoma and analyzed the receiver operating characteristic (ROC) curve to determine the optimum threshold value for each parameter and its corresponding sensitivity and specificity. Carcinosarcomas demonstrated significantly higher mean vales of ADC, 95th, 90th, 75th, 50th, 25th percentiles and kurtosis than endometrial carcinomas (P < 0.05). ROC curve analysis of the 75th percentile yielded the best area under the ROC curve (AUC; 0.904), sensitivity of 100%, and specificity of 78.0%, with a cutoff value of 1.034 × 10(-3) mm(2) /s. Histogram analysis of ADC maps might be helpful for discriminating uterine carcinosarcomas and endometrial carcinomas. J. Magn. Reson. Imaging 2016;43:1301-1307. © 2015 Wiley Periodicals, Inc.
Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie
2014-07-01
To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.
Nørrelykke, Simon F; Flyvbjerg, Henrik
2010-07-01
Optical tweezers and atomic force microscope (AFM) cantilevers are often calibrated by fitting their experimental power spectra of Brownian motion. We demonstrate here that if this is done with typical weighted least-squares methods, the result is a bias of relative size between -2/n and +1/n on the value of the fitted diffusion coefficient. Here, n is the number of power spectra averaged over, so typical calibrations contain 10%-20% bias. Both the sign and the size of the bias depend on the weighting scheme applied. Hence, so do length-scale calibrations based on the diffusion coefficient. The fitted value for the characteristic frequency is not affected by this bias. For the AFM then, force measurements are not affected provided an independent length-scale calibration is available. For optical tweezers there is no such luck, since the spring constant is found as the ratio of the characteristic frequency and the diffusion coefficient. We give analytical results for the weight-dependent bias for the wide class of systems whose dynamics is described by a linear (integro)differential equation with additive noise, white or colored. Examples are optical tweezers with hydrodynamic self-interaction and aliasing, calibration of Ornstein-Uhlenbeck models in finance, models for cell migration in biology, etc. Because the bias takes the form of a simple multiplicative factor on the fitted amplitude (e.g. the diffusion coefficient), it is straightforward to remove and the user will need minimal modifications to his or her favorite least-squares fitting programs. Results are demonstrated and illustrated using synthetic data, so we can compare fits with known true values. We also fit some commonly occurring power spectra once-and-for-all in the sense that we give their parameter values and associated error bars as explicit functions of experimental power-spectral values.
Zhang, Lina; Hu, Jiani; Guys, Nicholas; Meng, Jinli; Chu, Jianguo; Zhang, Weisheng; Liu, Ailian; Wang, Shaowu; Song, Qingwei
2018-03-01
To demonstrate the value of diffusion-weighted imaging (DWI) in the characterisation of mastitis lesions. Sixty-one non-puerperal patients with pathologically confirmed single benign mastitis lesions underwent preoperative examinations with conventional MRI and axial DWI. Patients were categorised into three groups: (1) periductal mastitis (PDM), (2) granulomatous lobular mastitis (GLM), and (3) infectious abscess (IAB). Apparent diffusion coefficient (ADC) values of each lesion were recorded. A one-way ANOVA with logistic analysis was performed to compare ADC values and other parameters. Discriminative abilities of DWI modalities were compared using the area under the receiver operating characteristic curve (AUC). P < 0.05 was considered statistically significant. ADC values differed significantly among the three groups (P = 0.003) as well as between PDM and IAB and between PDM and GLM. The distribution of non-mass enhancement on dynamic contrast-enhanced (DCE) MRI differed significantly among the three groups (P = 0.03) but not between any two groups specifically. There were no differences in lesion location, patient age, T 2 WI or DWI signal intensity, enhancement type, non-mass internal enhancement, or mass enhancement characteristics among the three groups. ADC values and the distribution of non-mass enhancement are valuable in classifying mastitis subtypes. • Mastitis subtypes exhibit different characteristics on DWI and DCE MRI. • ADC values are helpful in isolating PDM from other mastitis lesions. • Distribution of non-mass enhancement also has value in comparing mastitis subtypes.
Xu, Xiao-Quan; Li, Yan; Hong, Xun-Ning; Wu, Fei-Yun; Shi, Hai-Bin
2017-02-01
To assess the role of whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in differentiating radiological indeterminate vestibular schwannoma (VS) from meningioma in cerebellopontine angle (CPA). Diffusion-weighted (DW) images (b = 0 and 1000 s/mm 2 ) of pathologically confirmed and radiological indeterminate CPA meningioma (CPAM) (n = 27) and VS (n = 12) were retrospectively collected and processed with mono-exponential model. Whole-tumor regions of interest were drawn on all slices of the ADC maps to obtain histogram parameters, including the mean ADC (ADC mean ), median ADC (ADC median ), 10th/25th/75th/90th percentile ADC (ADC 10 , ADC 25 , ADC 75 and ADC 90 ), skewness and kurtosis. The differences of ADC histogram parameters between CPAM and VS were compared using unpaired t-test. Multiple receiver operating characteristic (ROC) curves analysis was used to determine and compare the diagnostic value of each significant parameter. Significant differences were found on the ADC mean , ADC median , ADC 10 , ADC 25 , ADC 75 and ADC 90 between CPAM and VS (all p values < 0.001), while no significant difference was found on kurtosis (p = 0.562) and skewness (p = 0.047). ROC curves analysis revealed, a cut-off value of 1.126 × 10 -3 mm 2 /s for the ADC 90 value generated highest area under curves (AUC) for differentiating CPAM from VS (AUC, 0.975; sensitivity, 100%; specificity, 88.9%). Histogram analysis of ADC maps based on whole tumor can be a useful tool for differentiating radiological indeterminate CPAM from VS. The ADC 90 value was the most promising parameter for differentiating these two entities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zieba, P.; Gust, W.
1999-07-09
The morphology and kinetics of the discontinuous precipitation (DP) and discontinuous dissolution (DD) reactions have been studied in a Ni-4 at.% Sn alloy. High spatial resolution energy-dispersive X-ray microanalysis has been used to determine the Sn concentration profiles left behind the moving reaction front for the individual cells of the Sn-depleted [alpha] lamellae and Ni[sub 3]Sn compound. These data, combined with the local values of the reaction front velocity and the thickness of the [alpha]lamellae, have been used to evaluate the local s[delta]D[sub b] values (D[sub b] is the grain-boundary chemical diffusion coefficient, [delta] is the grain-boundary thickness and smore » is the segregation factor). The obtained results have been compared with those calculated by the global approach to the DP and DD reactions, which is relevant for the whole population of the cells. It has been shown that the application of the local characterization of the DP and DD reactions removes essentially the differences between the s[delta]D[sub b] values calculated by the Petermann-Hornbogen equation and the equations of Cahn and Zieba-Pawlowski. Moreover, both sets of data do not show any substantial differences from the s[delta]D[sub b] values obtained from measurements of the tracer diffusion of tin along stationary grain boundaries in nickel.« less
21 CFR 172.260 - Oxidized polyethylene.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ADDITIVES PERMITTED FOR DIRECT ADDITION TO FOOD FOR HUMAN CONSUMPTION Coatings, Films and Related Substances... average molecular weight of 1,200, as determined by high temperature vapor pressure osmometry; contains a maximum of 5 percent by weight of total oxygen; and has an acid value of 9 to 19. (b) The additive is used...
Meng, Jie; Zhu, Lijing; Zhu, Li; Wang, Huanhuan; Liu, Song; Yan, Jing; Liu, Baorui; Guan, Yue; Ge, Yun; He, Jian; Zhou, Zhengyang; Yang, Xiaofeng
2016-10-22
To explore the role of apparent diffusion coefficient (ADC) histogram shape related parameters in early assessment of treatment response during the concurrent chemo-radiotherapy (CCRT) course of advanced cervical cancers. This prospective study was approved by the local ethics committee and informed consent was obtained from all patients. Thirty-two patients with advanced cervical squamous cell carcinomas underwent diffusion weighted magnetic resonance imaging (b values, 0 and 800 s/mm 2 ) before CCRT, at the end of 2nd and 4th week during CCRT and immediately after CCRT completion. Whole lesion ADC histogram analysis generated several histogram shape related parameters including skewness, kurtosis, s-sD av , width, standard deviation, as well as first-order entropy and second-order entropies. The averaged ADC histograms of 32 patients were generated to visually observe dynamic changes of the histogram shape following CCRT. All parameters except width and standard deviation showed significant changes during CCRT (all P < 0.05), and their variation trends fell into four different patterns. Skewness and kurtosis both showed high early decline rate (43.10 %, 48.29 %) at the end of 2nd week of CCRT. All entropies kept decreasing significantly since 2 weeks after CCRT initiated. The shape of averaged ADC histogram also changed obviously following CCRT. ADC histogram shape analysis held the potential in monitoring early tumor response in patients with advanced cervical cancers undergoing CCRT.
Diffusion-weighted MR of the brain: methodology and clinical application.
Mascalchi, Mario; Filippi, Massimo; Floris, Roberto; Fonda, Claudio; Gasparotti, Roberto; Villari, Natale
2005-03-01
Clinical diffusion magnetic resonance (MR) imaging in humans started in the last decade with the demonstration of the capabilities of this technique of depicting the anatomy of the white matter fibre tracts in the brain. Two main approaches in terms of reconstruction and evaluation of the images obtained with application of diffusion sensitising gradients to an echo planar imaging sequence are possible. The first approach consists of reconstruction of images in which the effect of white matter anisotropy is averaged -- known as the isotropic or diffusion weighted images, which are usually evaluated subjectively for possible areas of increased or decreased signal, reflecting restricted and facilitated diffusion, respectively. The second approach implies reconstruction of image maps of the apparent diffusion coefficient (ADC), in which the T2 weighting of the echo planar diffusion sequence is cancelled out, and their objective, i.e. numerical, evaluation with regions of interest or histogram analysis. This second approach enables a quantitative and reproducible assessment of the diffusion changes not only in areas exhibiting signal abnormality in conventional MR images but also in areas of normal signal. A further level of image post-processing requires the acquisition of images after application of sensitising gradients along at least 6 different spatial orientations and consists of computation of the diffusion tensor and reconstruction of maps of the mean diffusivity (D) and of the white matter anisotropic properties, usually in terms of fractional anisotropy (FA). Diffusion-weighted imaging is complementary to conventional MR imaging in the evaluation of the acute ischaemic stroke. The combination of diffusion and perfusion MR imaging has the potential of providing all the information necessary for the diagnosis and management of the individual patient with acute ischaemic stroke. Diffusion-weighted MR, in particular quantitative evaluation based on the diffusion tensor, has a fundamental role in the assessment of brain maturation and of white matter diseases in the fetus, in the neonate and in the child. Diffusion MR imaging enables a better characterisation of the lesions demonstrated by conventional MR imaging, for instance in the hypoxic-ischaemic encephalopathy, in infections and in the inherited metabolic diseases, and is particularly important for the longitudinal evaluation of these conditions. Diffusion-weighted MR imaging has an established role in the differential diagnosis between brain abscess and cystic tumour and between epidermoid tumour and arachnoid cyst. On the other hand, the results obtained with diffusion MR in the characterisation of type and extension of glioma do not yet allow decision making in the individual patient. Diffusion is one of the most relevant MR techniques to have contributed to a better understanding of the pathophysiological mechanisms of multiple sclerosis (MS). In fact, it improves the specificity of MR in characterising the different pathological substrata underlying the rather uniform lesion appearance on the conventional images and enables detection of damage in the normal-appearing white and grey matter. In MS patients the ADC or D values in the normal-appearing white matter are increased as compared to control values, albeit to a lesser degree than in the lesions demonstrated by T2-weighted images. In addition, the D of the normal appearing grey matter is increased in MS patients and this change correlates with the cognitive deficit of these patients. Histogram analysis in MS patients shows that the peak of the brain D is decreased and right-shifted, reflecting an increase of its value, and the two features correlate with the patient's clinical disability. Ageing is associated to a mild but significant increase of the brain ADC or D which is predominantly due to changes in the white matter. Region of interest and histogram studies have demonstrated that D or ADC are increased in either the areas of leukoaraiosis or the normal-appearing white matter in patients with inherited cerebral autosomal dominant arteriopathy with subcortical infarcts and stroke or sporadic ischaemic leukoencephalopathy. Diffusion changes might be a more sensitive marker for progression of the disease than conventional imaging findings. In neurodegenerative diseases of the central nervous system such as Alzheimer's disease, Huntington's disease, hereditary ataxias and motor neuron disease, quantitative diffusion MR demonstrates the cortical and subcortical grey matter damage, which is reflected in a regional increase of D or ADC, but also reveals the concomitant white matter changes that are associated with an increase in D or ADC and decrease in FA. In all these diseases the diffusion changes are correlated to the clinical deficit and are potentially useful for early diagnosis and longitudinal evaluation, especially in the context of pharmacological trials.
Anomalous cross-B field transport and spokes in HiPIMS plasma
NASA Astrophysics Data System (ADS)
Hecimovic, Ante; Maszl, Christian; Schulz-von der Gathen, Volker; von Keudell, Achim
2016-09-01
The rotation of localised ionisation zones, i.e. spokes, in magnetron discharge is investigated as a function of discharge current, ranging from 10 mA (current density 0.5 mA cm-2) to 140 A (7 A cm-2) . The presence of spokes throughout the complete discharge current range indicates that the spokes are an intrinsic property of a magnetron sputtering plasma discharge. Up to discharge currents of several amperes, the spokes rotate in a retrograde ExB direction and beyond the spokes rotate in a ExB direction. In this contribution we present experimental evidence that anomalous diffusion is triggered by the appearance of spokes rotating in the ExB direction. The Hall parameter ωceτc , product of the electron cyclotron frequency and the classical collision time, reduces from Bohm diffusion values (16 and higher) down to the value of 3 as spokes appear, indicating anomalous cross-B field transport. The ion diffusion coefficients calculated from a sideways image of the spoke is six times higher than Bohm diffusion coefficients, which is consistent with the reduction of the Hall parameter.
Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K
2014-01-01
Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.
Ohno, Naoki; Kan, Hirohito; Miyati, Tosiaki; Aoki, Toshitaka; Ishida, Shota; Gabata, Toshifumi
2017-06-01
To obtain water and lipid diffusion-weighted images (DWIs) simultaneously, we devised a novel method utilizing chemical shift displacement-based separation of lipid tissue (SPLIT) imaging. Single-shot diffusion echo-planar imaging without fat suppression was used and the imaging parameters were optimized to separate water and lipid DWIs by chemical shift displacement of the lipid signals along the phase-encoding direction. Using the optimized conditions, transverse DWIs at the maximum diameter of the right calf were scanned with multiple b-values in five healthy subjects. Then, apparent diffusion coefficients (ADCs) were calculated in the tibialis anterior muscle (TA), tibialis bone marrow (TB), and subcutaneous fat (SF), as well as restricted and perfusion-related diffusion coefficients (D and D*, respectively) and the fraction of the perfusion-related diffusion component (F) for TA. Water and lipid DWIs were separated adequately. The mean ADCs of the TA, TB, and SF were 1.56±0.03mm 2 /s, 0.01±0.01mm 2 /s, and 0.06±0.02mm 2 /s, respectively. The mean D*, D, and F of the TA were 13.7±4.3mm 2 /s, 1.48±0.05mm 2 /s, and 4.3±1.6%, respectively. SPLIT imaging makes it possible to simply and simultaneously obtain water and lipid DWIs without special pulse sequence and increases the amount of diffusion information of water and lipid tissue. Copyright © 2017. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Y; Cao, M; Kamrava, M
Purpose: Diffusion weighted MRI (DWI) is a promising imaging technique for early prediction of tumor response to radiation therapy. A recently proposed longitudinal DWI strategy using a Co-60 MRI guided RT system (MRIgRT) may bring functional MRI guided adaptive radiation therapy closer to clinical utility. We report our preliminary results of using this longitudinal DWI approach performed on the MRIgRT system for predicting the response of sarcoma patient to preop RT. Methods: Three sarcoma patients who underwent fractionated IMRT were recruited in this study. For all three patients DWI images were acquired immediately following his/her treatment. For each imaging session,more » ten slices were acquired interleaved with the b values covering the gross tumor volume (GTV). The diffusion images were processed to obtain the ADC maps using standard exponential fitting for each voxel. Regions of interest were drawn in the tumor on the diffusion images based on each patient’s clinical GTV contours. Each patient subsequently underwent surgery and the tumor necrosis score was available from standard pathology. The ADC values for each patient were compared to the necrosis scores to assess the predictive value of our longitudinal DWI for tumor response. Results: Each patient underwent 3 to 5 diffusion MRI scans depending on their treatment length. Patient 1 had a relatively unchanged ADC during the course of RT and a necrosis score of 30% at surgery. For patient 2, the mean ADC values decreased from 1.56 × 10-3 to 1.12 × 10-3 mm2/s and the patient’s necrosis score was less than 10%. Patient 3 had a slight increase in the ADC values from 0.59 × 10-3 to 0.71 × 10-3 mm2/s and patient’s necrosis score was 50%. Conclusion: Based on limited data from 3 patients, our longitudinal changes in tumor ADC assessed using the MRIgRT system correlated well with pathology results.« less
Wang, Cuiyan; Eghtedari, Mohammad; Yang, Wei Tse; Dogan, Basak Erguvan
2018-03-22
Clinical differentiation of atypical breast abscesses from necrotic tumour in premenopausal women is challenging and may delay appropriate therapy. In this case report, we present a 36-year-old woman with signs, symptoms and conventional imaging features of malignancy who underwent breast MRI. On diffusion-weighted imaging (DWI), profoundly low apparent diffusion coefficient values were a distinguishing sign of breast abscess from necrotic breast cancer, and helped manage the patient conservatively. We present a companion case of necrotic breast tumour highlighting significant differences in DWI. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Chang, Hing-Chiu; Guhaniyogi, Shayan; Chen, Nan-kuei
2014-01-01
Purpose We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion weighted imaging (DWI). Methods First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction algorithm, so that images reconstructed from interleaved partial-Fourier DWI data are free from artifacts even in the presence of either a) motion-induced k-space energy peak displacement, or b) susceptibility field gradient induced fast phase changes. Second, we generalize the previously reported single-band MUSE framework to multi-band MUSE, so that both through-plane and in-plane aliasing artifacts in multi-band multi-shot interleaved DWI data can be effectively eliminated. Results The new adaptive Homodyne-MUSE reconstruction algorithm reliably produces high-quality and high-resolution DWI, eliminating residual artifacts in images reconstructed with previously reported methods. Furthermore, the generalized MUSE algorithm is compatible with multi-band and high-throughput DWI. Conclusion The integration of the multi-band and adaptive Homodyne-MUSE algorithms significantly improves the spatial-resolution, image quality, and scan throughput of interleaved DWI. We expect that the reported reconstruction framework will play an important role in enabling high-resolution DWI for both neuroscience research and clinical uses. PMID:24925000
Influence of oxygen therapy on glucose-lactate metabolism after diffuse brain injury.
Reinert, Michael; Schaller, Benoit; Widmer, Hans Rudolf; Seiler, Rolf; Bullock, Ross
2004-08-01
Severe traumatic brain injury (TBI) imposes a huge metabolic load on brain tissue, which can be summarized initially as a state of hypermetabolism and hyperglycolysis. In experiments O2 consumption has been shown to increase early after trauma, especially in the presence of high lactate levels and forced O2 availability. In recent clinical studies the effect of increasing O2 availability on brain metabolism has been analyzed. By their nature, however, clinical trauma models suffer from a heterogeneous injury distribution. The aim of this study was to analyze, in a standardized diffuse brain injury model, the effect of increasing the fraction of inspired O2 on brain glucose and lactate levels, and to compare this effect with the metabolism of the noninjured sham-operated brain. A diffuse severe TBI model developed by Foda and Maramarou, et al., in which a 420-g weight is dropped from a height of 2 m was used in this study. Forty-one male Wistar rats each weighing approximately 300 g were included. Anesthesized rats were monitored by placing a femoral arterial line for blood pressure and blood was drawn for a blood gas analysis. Two time periods were defined: Period A was defined as preinjury and Period B as postinjury. During Period B two levels of fraction of inspired oxygen (FiO2) were studied: air (FiO2 0.21) and oxygen (FiO2 1). Four groups were studied including sham-operated animals: air-air-sham (AAS); air-O2-sham (AOS); air-air-trauma (AAT); and air-O2-trauma (AOT). In six rats the effect of increasing the FiO2 on serum glucose and lactate was analyzed. During Period B lactate values in the brain determined using microdialysis were significantly lower (p < 0.05) in the AOT group than in the AAT group and glucose values in the brain determined using microdialysis were significantly higher (p < 0.04). No differences were demonstrated in the other groups. Increasing the FiO2 had no significant effect on the serum levels of glucose and lactate. Increasing the FiO2 influences dialysate glucose and lactate levels in injured brain tissue. Using an FiO2 of 1 influences brain metabolism in such a way that lactate is significantly reduced and glucose significantly increased. No changes in dialysate glucose and lactate values were found in the noninjured brain.
High resolution human diffusion tensor imaging using 2-D navigated multi-shot SENSE EPI at 7 Tesla
Jeong, Ha-Kyu; Gore, John C.; Anderson, Adam W.
2012-01-01
The combination of parallel imaging with partial Fourier acquisition has greatly improved the performance of diffusion-weighted single-shot EPI and is the preferred method for acquisitions at low to medium magnetic field strength such as 1.5 or 3 Tesla. Increased off-resonance effects and reduced transverse relaxation times at 7 Tesla, however, generate more significant artifacts than at lower magnetic field strength and limit data acquisition. Additional acceleration of k-space traversal using a multi-shot approach, which acquires a subset of k-space data after each excitation, reduces these artifacts relative to conventional single-shot acquisitions. However, corrections for motion-induced phase errors are not straightforward in accelerated, diffusion-weighted multi-shot EPI because of phase aliasing. In this study, we introduce a simple acquisition and corresponding reconstruction method for diffusion-weighted multi-shot EPI with parallel imaging suitable for use at high field. The reconstruction uses a simple modification of the standard SENSE algorithm to account for shot-to-shot phase errors; the method is called Image Reconstruction using Image-space Sampling functions (IRIS). Using this approach, reconstruction from highly aliased in vivo image data using 2-D navigator phase information is demonstrated for human diffusion-weighted imaging studies at 7 Tesla. The final reconstructed images show submillimeter in-plane resolution with no ghosts and much reduced blurring and off-resonance artifacts. PMID:22592941
Wargo, Christopher J.; Gore, John C.
2013-01-01
Localized high-resolution diffusion tensor images (DTI) from the midbrain were obtained using reduced field-of-view (rFOV) methods combined with SENSE parallel imaging and single-shot echo planar (EPI) acquisitions at 7 T. This combination aimed to diminish sensitivities of DTI to motion, susceptibility variations, and EPI artifacts at ultra-high field. Outer-volume suppression (OVS) was applied in DTI acquisitions at 2- and 1-mm2 resolutions, b=1000 s/mm2, and six diffusion directions, resulting in scans of 7- and 14-min durations. Mean apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured in various fiber tract locations at the two resolutions and compared. Geometric distortion and signal-to-noise ratio (SNR) were additionally measured and compared for reduced-FOV and full-FOV DTI scans. Up to an eight-fold data reduction was achieved using DTI-OVS with SENSE at 1 mm2, and geometric distortion was halved. The localization of fiber tracts was improved, enabling targeted FA and ADC measurements. Significant differences in diffusion properties were observed between resolutions for a number of regions suggesting that FA values are impacted by partial volume effects even at a 2-mm2 resolution. The combined SENSE DTI-OVS approach allows large reductions in DTI data acquisition and provides improved quality for high-resolution diffusion studies of the human brain. PMID:23541390
Mosavi, Firas; Laurell, Anna; Ahlström, Håkan
2015-11-01
Whole body (WB) magnetic resonance imaging (MRI), including diffusion-weighted imaging (DWI) has become increasingly utilized in cancer imaging, yet the clinical utility of these techniques in follow-up of testicular cancer patients has not been evaluated. The purpose of this study was to evaluate the feasibility of WB MRI with continuous table movement (CTM) technique, including multistep DWI in follow-up of patients with testicular cancer. WB MRI including DWI was performed in follow-up of 71 consecutive patients (median age, 37 years; range 19-84) with histologically confirmed testicular cancer. WB MRI protocol included axial T1-Dixon and T2-BLADE sequences using CTM technique. Furthermore, multi-step DWI was performed using b-value 50 and 1000 s/mm(2). One criterion for feasibility was patient tolerance and satisfactory image quality. Another criterion was the accuracy in detection of any pathological mass, compared to standard of reference. Signal intensity in DWI was used for evaluation of residual mass activity. Clinical, laboratory and imaging follow-up were applied as standard of reference for the evaluation of WB MRI. WB MRI was tolerated in nearly all patients (69/71 patients, 97%) and the image quality was satisfactory. Metal artifacts deteriorated the image quality in six patients, but it did not influence the overall results. No case of clinical relapse was observed during the follow-up time. There was a good agreement between conventional WB MRI and standard of reference in all patients. Three patients showed residual masses and DWI signal was not restricted in these patients. Furthermore, DWI showed abnormally high signal intensity in a normal-sized retroperitoneal lymph node indicating metastasis. The subsequent (18)F-FDG PET/CT could verify the finding. WB MRI with CTM technique including multi-step DWI is feasible in follow-up of patients with testicular cancer. DWI may contribute to important added-value data to conventional MRI sequences regarding the activity of residual masses.
Hiwatashi, A; Togao, O; Yamashita, K; Kikuchi, K; Momosaka, D; Honda, H
2018-03-20
The purpose of this study was to correlate diffusivity of extraocular muscles, measured by three-dimensional turbo field echo (3DTFE) magnetic resonance (MR) imaging using diffusion-sensitized driven-equilibrium preparation, with their size and activity in patients with Grave's ophthalmopathy. Twenty-three patients with Grave's ophthalmopathy were included. There were 17 women and 6 men with a mean age of 55.8±12.6 (SD) years (range: 26-83 years). 3DTFE with diffusion-sensitized driven-equilibrium MR images were obtained with b-values of 0 and 500s/mm 2 . The apparent diffusion coefficient (ADC) of extraocular muscles was measured on coronal reformatted MR images. Signal intensities of extraocular muscles on conventional MR images were compared to those of normal-appearing white matter, and cross-sectional areas of the muscles were also measured. The clinical activity score was also evaluated. Statistical analyses were performed with Pearson correlation and Mann-Whitney U tests. On 3DTFE with diffusion-sensitized driven-equilibrium preparation, the mean ADC of the extraocular muscles was 2.23±0.37 (SD)×10 -3 mm2/s (range: 1.70×10 -3 -3.11×10 -3 mm 2 /s). There was a statistically significant moderate correlation between ADC and the size of the muscles (r=0.61). There were no statistically significant correlations between ADC and signal intensity on conventional MR and the clinical activity score. 3DTFE with diffusion-sensitized driven-equilibrium preparation technique allows quantifying diffusivity of extraocular muscles in patients with Grave's ophthalmopathy. The diffusivity of the extraocular muscles on 3DTFE with diffusion-sensitized driven-equilibrium preparation MR images moderately correlates with their size. Copyright © 2018. Published by Elsevier Masson SAS.
Jeurissen, Ben; Leemans, Alexander; Sijbers, Jan
2014-10-01
Ensuring one is using the correct gradient orientations in a diffusion MRI study can be a challenging task. As different scanners, file formats and processing tools use different coordinate frame conventions, in practice, users can end up with improperly oriented gradient orientations. Using such wrongly oriented gradient orientations for subsequent diffusion parameter estimation will invalidate all rotationally variant parameters and fiber tractography results. While large misalignments can be detected by visual inspection, small rotations of the gradient table (e.g. due to angulation of the acquisition plane), are much more difficult to detect. In this work, we propose an automated method to align the coordinate frame of the gradient orientations with that of the corresponding diffusion weighted images, using a metric based on whole brain fiber tractography. By transforming the gradient table and measuring the average fiber trajectory length, we search for the transformation that results in the best global 'connectivity'. To ensure a fast calculation of the metric we included a range of algorithmic optimizations in our tractography routine. To make the optimization routine robust to spurious local maxima, we use a stochastic optimization routine that selects a random set of seed points on each evaluation. Using simulations, we show that our method can recover the correct gradient orientations with high accuracy and precision. In addition, we demonstrate that our technique can successfully recover rotated gradient tables on a wide range of clinically realistic data sets. As such, our method provides a practical and robust solution to an often overlooked pitfall in the processing of diffusion MRI. Copyright © 2014 Elsevier B.V. All rights reserved.
New Insights into the Fractional Order Diffusion Equation Using Entropy and Kurtosis.
Ingo, Carson; Magin, Richard L; Parrish, Todd B
2014-11-01
Fractional order derivative operators offer a concise description to model multi-scale, heterogeneous and non-local systems. Specifically, in magnetic resonance imaging, there has been recent work to apply fractional order derivatives to model the non-Gaussian diffusion signal, which is ubiquitous in the movement of water protons within biological tissue. To provide a new perspective for establishing the utility of fractional order models, we apply entropy for the case of anomalous diffusion governed by a fractional order diffusion equation generalized in space and in time. This fractional order representation, in the form of the Mittag-Leffler function, gives an entropy minimum for the integer case of Gaussian diffusion and greater values of spectral entropy for non-integer values of the space and time derivatives. Furthermore, we consider kurtosis, defined as the normalized fourth moment, as another probabilistic description of the fractional time derivative. Finally, we demonstrate the implementation of anomalous diffusion, entropy and kurtosis measurements in diffusion weighted magnetic resonance imaging in the brain of a chronic ischemic stroke patient.
Motion-induced phase error estimation and correction in 3D diffusion tensor imaging.
Van, Anh T; Hernando, Diego; Sutton, Bradley P
2011-11-01
A multishot data acquisition strategy is one way to mitigate B0 distortion and T2∗ blurring for high-resolution diffusion-weighted magnetic resonance imaging experiments. However, different object motions that take place during different shots cause phase inconsistencies in the data, leading to significant image artifacts. This work proposes a maximum likelihood estimation and k-space correction of motion-induced phase errors in 3D multishot diffusion tensor imaging. The proposed error estimation is robust, unbiased, and approaches the Cramer-Rao lower bound. For rigid body motion, the proposed correction effectively removes motion-induced phase errors regardless of the k-space trajectory used and gives comparable performance to the more computationally expensive 3D iterative nonlinear phase error correction method. The method has been extended to handle multichannel data collected using phased-array coils. Simulation and in vivo data are shown to demonstrate the performance of the method.
Benndorf, Matthias; Hahn, Felix; Krönig, Malte; Jilg, Cordula Annette; Krauss, Tobias; Langer, Mathias; Dovi-Akué, Philippe
2017-08-01
To examine the diagnostic performance of PI-RADSv2 T2w and diffusion weighted imaging (DWI) based lexicon descriptors, inter-observer agreement for descriptor assignment and diagnostic accuracy of the PI-RADSv2 assessment categories for multiparametric prostate MRI. 176 lesions in 79 consecutive patients are analyzed, lesions are histopathologically verified by MRI-ultrasound fusion biopsy. All lesions are rated according to the PI-RADSv2 lexicon, descriptors for T2w and DWI sequences and resulting assessment categories are assigned by two independent blinded radiologists. We perform receiver-operating-characteristic analysis using the assessment categories. To analyze inter-observer agreement, we calculate weighted kappa values for assessment category assignment and unweighted kappa values for descriptor assignment. PI-RADSv2 assessment categories yield an area under the curve of 0.76/0.74 (radiologist 1/radiologist 2), P >0.05. Weighted kappa for agreement is 0.601 in the peripheral zone and 0.580 in the transition zone. We detect a difference in the cancer rate for PI-RADSv2 category 3 between peripheral zone (32%) and transition zone (12%), P <0.05. We obtain moderate agreement at most for descriptor assignment with kappa values ranging from 0.082 (T2w shape in the transition zone) to 0.407 (T2w signal intensity in the peripheral zone) and 0.493 (ADC pattern in the peripheral zone). Our analysis corroborates typical descriptors for benign/malignant lesions, but also reveals insights into potential pitfalls - T2w wedge shaped lesions in the peripheral zone have a considerable cancer rate, despite being labelled category 2 in the lexicon. Agreement for descriptor assignment in the PI-RADSv2 lexicon is at most moderate in our study. Typical descriptors for benign and malignant lesions are validated, whereas the discriminatory power of some descriptors is challenged. The difference in the cancer rate for PI-RADSv2 category 3 between peripheral zone and transition zone should be considered when management recommendations are linked to assessment categories in the future. Copyright © 2017 Elsevier B.V. All rights reserved.
Nicholson, C; Tao, L
1993-12-01
This paper describes the theory of an integrative optical imaging system and its application to the analysis of the diffusion of 3-, 10-, 40-, and 70-kDa fluorescent dextran molecules in agarose gel and brain extracellular microenvironment. The method uses a precisely defined source of fluorescent molecules pressure ejected from a micropipette, and a detailed theory of the intensity contributions from out-of-focus molecules in a three-dimensional medium to a two-dimensional image. Dextrans tagged with either tetramethylrhodamine or Texas Red were ejected into 0.3% agarose gel or rat cortical slices maintained in a perfused chamber at 34 degrees C and imaged using a compound epifluorescent microscope with a 10 x water-immersion objective. About 20 images were taken at 2-10-s intervals, recorded with a cooled CCD camera, then transferred to a 486 PC for quantitative analysis. The diffusion coefficient in agarose gel, D, and the apparent diffusion coefficient, D*, in brain tissue were determined by fitting an integral expression relating the measured two-dimensional image intensity to the theoretical three-dimensional dextran concentration. The measurements in dilute agarose gel provided a reference value of D and validated the method. Values of the tortuosity, lambda = (D/D*)1/2, for the 3- and 10-kDa dextrans were 1.70 and 1.63, respectively, which were consistent with previous values derived from tetramethylammonium measurements in cortex. Tortuosities for the 40- and 70-kDa dextrans had significantly larger values of 2.16 and 2.25, respectively. This suggests that the extracellular space may have local constrictions that hinder the diffusion of molecules above a critical size that lies in the range of many neurotrophic compounds.
The large lungs of elite swimmers: an increased alveolar number?
Armour, J; Donnelly, P M; Bye, P T
1993-02-01
In order to obtain further insight into the mechanisms relating to the large lung volumes of swimmers, tests of mechanical lung function, including lung distensibility (K) and elastic recoil, pulmonary diffusion capacity, and respiratory mouth pressures, together with anthropometric data (height, weight, body surface area, chest width, depth and surface area), were compared in eight elite male swimmers, eight elite male long distance athletes and eight control subjects. The differences in training profiles of each group were also examined. There was no significant difference in height between the subjects, but the swimmers were younger than both the runners and controls, and both the swimmers and controls were heavier than the runners. Of all the training variables, only the mean total distance in kilometers covered per week was significantly greater in the runners. Whether based on: (a) adolescent predicted values; or (b) adult male predicted values, swimmers had significantly increased total lung capacity ((a) 145 +/- 22%, (mean +/- SD) (b) 128 +/- 15%); vital capacity ((a) 146 +/- 24%, (b) 124 +/- 15%); and inspiratory capacity ((a) 155 +/- 33%, (b) 138 +/- 29%), but this was not found in the other two groups. Swimmers also had the largest chest surface area and chest width. Forced expiratory volume in one second (FEV1) was largest in the swimmers ((b) 122 +/- 17%) and FEV1 as a percentage of forced vital capacity (FEV1/FVC)% was similar for the three groups. Pulmonary diffusing capacity (DLCO) was also highest in the swimmers (117 +/- 18%). All of the other indices of lung function, including pulmonary distensibility (K), elastic recoil and diffusion coefficient (KCO), were similar. These findings suggest that swimmers may have achieved greater lung volumes than either runners or control subjects, not because of greater inspiratory muscle strength, or differences in height, fat free mass, alveolar distensibility, age at start of training or sternal length or chest depth, but by developing physically wider chests, containing an increased number of alveoli, rather than alveoli of increased size. However, in this cross-sectional study, hereditary factors cannot be ruled out, although we believe them to be less likely.
Sepehrband, Farshid; Clark, Kristi A.; Ullmann, Jeremy F.P.; Kurniawan, Nyoman D.; Leanage, Gayeshika; Reutens, David C.; Yang, Zhengyi
2015-01-01
We examined whether quantitative density measures of cerebral tissue consistent with histology can be obtained from diffusion magnetic resonance imaging (MRI). By incorporating prior knowledge of myelin and cell membrane densities, absolute tissue density values were estimated from relative intra-cellular and intra-neurite density values obtained from diffusion MRI. The NODDI (neurite orientation distribution and density imaging) technique, which can be applied clinically, was used. Myelin density estimates were compared with the results of electron and light microscopy in ex vivo mouse brain and with published density estimates in a healthy human brain. In ex vivo mouse brain, estimated myelin densities in different sub-regions of the mouse corpus callosum were almost identical to values obtained from electron microscopy (Diffusion MRI: 42±6%, 36±4% and 43±5%; electron microscopy: 41±10%, 36±8% and 44±12% in genu, body and splenium, respectively). In the human brain, good agreement was observed between estimated fiber density measurements and previously reported values based on electron microscopy. Estimated density values were unaffected by crossing fibers. PMID:26096639
Cross Helicity and Turbulent Magnetic Diffusivity in the Solar Convection Zone
NASA Astrophysics Data System (ADS)
Rüdiger, G.; Kitchatinov, L. L.; Brandenburg, A.
2011-03-01
In a density-stratified turbulent medium, the cross helicity < u'ṡ B'> is considered as a result of the interaction of the velocity fluctuations and a large-scale magnetic field. By means of a quasilinear theory and by numerical simulations, we find the cross helicity and the mean vertical magnetic field to be anti-correlated. In the high-conductivity limit the ratio of the helicity and the mean magnetic field equals the ratio of the magnetic eddy diffusivity and the (known) density scale height. The result can be used to predict that the cross helicity at the solar surface will exceed the value of 1 gauss km s-1. Its sign is anti-correlated to that of the radial mean magnetic field. Alternatively, we can use our result to determine the value of the turbulent magnetic diffusivity from observations of the cross helicity.
Balci, N Cem; Momtahen, Amir Javad; Akduman, E Isin; Alkaade, Samer; Bilgin, Mehmet; Burton, Frank R
2008-10-01
To evaluate the correlation between apparent diffusion coefficient (ADC) values of the pancreas on diffusion-weighted imaging (DWI) and pancreatic exocrine function determined by HCO(3) concentration in the secretin endoscopic pancreatic function test (ePFT). Mean ADC values derived from 10 different points of the pancreatic gland on DWI were reviewed in 14 patients with normal (peak HCO(3) > or = 80 mEq/L) and 14 patients with abnormal (peak HCO(3) < 80 mEq/L) ePFT results. Magnetic resonance cholangiopancreatography (MRCP) images of the same patients were evaluated for the diagnosis of chronic pancreatitis. Correlation between ADC values and HCO(3) concentration as well as Cambridge scores in MRCP was performed using Spearman's correlation test. Mean ADC value of the pancreas was 1.52 +/- 0.13 x 10(-3) mm(2)/s in patients with abnormal ePFT results and 1.78 +/- 0.07 x 10(-3) mm(2)/s in the normal group. There was a significant statistical difference between the ADC values of the pancreas in the two groups (P < .0001). There was also a statistically significant correlation between HCO(3) level and ADC value of the pancreas in the study patients (r = 0.771, P < .0001). Morphologic changes of the pancreas according to the Cambridge classification were also well correlated with the mean ADC values (r = -0.763, P < .0001). Strong correlation between ADC value and pancreatic exocrine function as well as Cambridge score for chronic pancreatitis exists. Further studies are needed to determine the cut off ADC value for chronic pancreatitis.
Jovicich, Jorge; Marizzoni, Moira; Bosch, Beatriz; Bartrés-Faz, David; Arnold, Jennifer; Benninghoff, Jens; Wiltfang, Jens; Roccatagliata, Luca; Picco, Agnese; Nobili, Flavio; Blin, Oliver; Bombois, Stephanie; Lopes, Renaud; Bordet, Régis; Chanoine, Valérie; Ranjeva, Jean-Philippe; Didic, Mira; Gros-Dagnac, Hélène; Payoux, Pierre; Zoccatelli, Giada; Alessandrini, Franco; Beltramello, Alberto; Bargalló, Núria; Ferretti, Antonio; Caulo, Massimo; Aiello, Marco; Ragucci, Monica; Soricelli, Andrea; Salvadori, Nicola; Tarducci, Roberto; Floridi, Piero; Tsolaki, Magda; Constantinidis, Manos; Drevelegas, Antonios; Rossini, Paolo Maria; Marra, Camillo; Otto, Josephin; Reiss-Zimmermann, Martin; Hoffmann, Karl-Titus; Galluzzi, Samantha; Frisoni, Giovanni B
2014-11-01
Large-scale longitudinal neuroimaging studies with diffusion imaging techniques are necessary to test and validate models of white matter neurophysiological processes that change in time, both in healthy and diseased brains. The predictive power of such longitudinal models will always be limited by the reproducibility of repeated measures acquired during different sessions. At present, there is limited quantitative knowledge about the across-session reproducibility of standard diffusion metrics in 3T multi-centric studies on subjects in stable conditions, in particular when using tract based spatial statistics and with elderly people. In this study we implemented a multi-site brain diffusion protocol in 10 clinical 3T MRI sites distributed across 4 countries in Europe (Italy, Germany, France and Greece) using vendor provided sequences from Siemens (Allegra, Trio Tim, Verio, Skyra, Biograph mMR), Philips (Achieva) and GE (HDxt) scanners. We acquired DTI data (2 × 2 × 2 mm(3), b = 700 s/mm(2), 5 b0 and 30 diffusion weighted volumes) of a group of healthy stable elderly subjects (5 subjects per site) in two separate sessions at least a week apart. For each subject and session four scalar diffusion metrics were considered: fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD) and axial (AD) diffusivity. The diffusion metrics from multiple subjects and sessions at each site were aligned to their common white matter skeleton using tract-based spatial statistics. The reproducibility at each MRI site was examined by looking at group averages of absolute changes relative to the mean (%) on various parameters: i) reproducibility of the signal-to-noise ratio (SNR) of the b0 images in centrum semiovale, ii) full brain test-retest differences of the diffusion metric maps on the white matter skeleton, iii) reproducibility of the diffusion metrics on atlas-based white matter ROIs on the white matter skeleton. Despite the differences of MRI scanner configurations across sites (vendors, models, RF coils and acquisition sequences) we found good and consistent test-retest reproducibility. White matter b0 SNR reproducibility was on average 7 ± 1% with no significant MRI site effects. Whole brain analysis resulted in no significant test-retest differences at any of the sites with any of the DTI metrics. The atlas-based ROI analysis showed that the mean reproducibility errors largely remained in the 2-4% range for FA and AD and 2-6% for MD and RD, averaged across ROIs. Our results show reproducibility values comparable to those reported in studies using a smaller number of MRI scanners, slightly different DTI protocols and mostly younger populations. We therefore show that the acquisition and analysis protocols used are appropriate for multi-site experimental scenarios. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Shu; Jiang, B. W.; Zhao, He; Chen, Xiaodian; de Grijs, Richard
2017-10-01
Understanding the effects of dust extinction is important to properly interpret observations. The optical total-to-selective extinction ratio, {R}V={A}V/E(B-V), is widely used to describe extinction variations in ultraviolet and optical bands. Since the {R}V=3.1 extinction curve adequately represents the average extinction law of diffuse regions in the Milky Way, it is commonly used to correct observational measurements along sightlines toward diffuse regions in the interstellar medium. However, the {R}V value may vary even along different diffuse interstellar medium sightlines. In this paper, we investigate the optical-mid-infrared (mid-IR) extinction law toward a very diffuse region at l=165^\\circ in the Galactic plane, which was selected based on a CO emission map. Adopting red clump stars as extinction tracers, we determine the optical-mid-IR extinction law for our diffuse region in two APASS bands (B,V), three XSTPS-GAC bands (g,r,I), three 2MASS bands (J,H,{K}s), and two WISE bands (W1,W2). Specifically, 18 red clump stars were selected from the APOGEE-RC catalog based on spectroscopic data in order to explore the diversity of the extinction law. We find that the optical extinction curves exhibit appreciable diversity. The corresponding {R}V ranges from 1.7 to 3.8, while the mean {R}V value of 2.8 is consistent with the widely adopted average value of 3.1 for Galactic diffuse clouds. There is no apparent correlation between {R}V value and color excess E(B-V) in the range of interest, from 0.2 to 0.6 mag, or with specific visual extinction per kiloparsec, {A}V/d.
Molecular weights and subunit structure of LamB proteins.
Nakae, T; Ishii, J N
1982-01-01
Phage lambda-receptor proteins of Escherichia coli, LamB proteins, form oligomeric aggregates to build transmembrane diffusion pores selective for maltose and maltodextrins. The molecular weights (MW) of functional oligomers as well as dissociated monomers were determined by sedimentation equilibrium analysis in homogeneous non-ionic surfactant and deuterium oxide and in 6 M guanidine-HCl, respectively. The MW of oligomers and monomers appeared as 135 600 and 45 900, respectively. Thus, functional Lamb proteins consisted of three identical subunits.
Schob, Stefan; Meyer, Hans Jonas; Dieckow, Julia; Pervinder, Bhogal; Pazaitis, Nikolaos; Höhn, Anne Kathrin; Garnov, Nikita; Horvath-Rizea, Diana; Hoffmann, Karl-Titus; Surov, Alexey
2017-04-12
Pre-surgical diffusion weighted imaging (DWI) is increasingly important in the context of thyroid cancer for identification of the optimal treatment strategy. It has exemplarily been shown that DWI at 3T can distinguish undifferentiated from well-differentiated thyroid carcinoma, which has decisive implications for the magnitude of surgery. This study used DWI histogram analysis of whole tumor apparent diffusion coefficient (ADC) maps. The primary aim was to discriminate thyroid carcinomas which had already gained the capacity to metastasize lymphatically from those not yet being able to spread via the lymphatic system. The secondary aim was to reflect prognostically important tumor-biological features like cellularity and proliferative activity with ADC histogram analysis. Fifteen patients with follicular-cell derived thyroid cancer were enrolled. Lymph node status, extent of infiltration of surrounding tissue, and Ki-67 and p53 expression were assessed in these patients. DWI was obtained in a 3T system using b values of 0, 400, and 800 s/mm². Whole tumor ADC volumes were analyzed using a histogram-based approach. Several ADC parameters showed significant correlations with immunohistopathological parameters. Most importantly, ADC histogram skewness and ADC histogram kurtosis were able to differentiate between nodal negative and nodal positive thyroid carcinoma. histogram analysis of whole ADC tumor volumes has the potential to provide valuable information on tumor biology in thyroid carcinoma. However, further studies are warranted.
Schob, Stefan; Meyer, Hans Jonas; Dieckow, Julia; Pervinder, Bhogal; Pazaitis, Nikolaos; Höhn, Anne Kathrin; Garnov, Nikita; Horvath-Rizea, Diana; Hoffmann, Karl-Titus; Surov, Alexey
2017-01-01
Pre-surgical diffusion weighted imaging (DWI) is increasingly important in the context of thyroid cancer for identification of the optimal treatment strategy. It has exemplarily been shown that DWI at 3T can distinguish undifferentiated from well-differentiated thyroid carcinoma, which has decisive implications for the magnitude of surgery. This study used DWI histogram analysis of whole tumor apparent diffusion coefficient (ADC) maps. The primary aim was to discriminate thyroid carcinomas which had already gained the capacity to metastasize lymphatically from those not yet being able to spread via the lymphatic system. The secondary aim was to reflect prognostically important tumor-biological features like cellularity and proliferative activity with ADC histogram analysis. Fifteen patients with follicular-cell derived thyroid cancer were enrolled. Lymph node status, extent of infiltration of surrounding tissue, and Ki-67 and p53 expression were assessed in these patients. DWI was obtained in a 3T system using b values of 0, 400, and 800 s/mm2. Whole tumor ADC volumes were analyzed using a histogram-based approach. Several ADC parameters showed significant correlations with immunohistopathological parameters. Most importantly, ADC histogram skewness and ADC histogram kurtosis were able to differentiate between nodal negative and nodal positive thyroid carcinoma. Conclusions: histogram analysis of whole ADC tumor volumes has the potential to provide valuable information on tumor biology in thyroid carcinoma. However, further studies are warranted. PMID:28417929
Kwee, Thomas C; Takahara, Taro; Koh, Dow-Mu; Nievelstein, Rutger A J; Luijten, Peter R
2008-11-01
To compare and determine the reproducibility of apparent diffusion coefficient (ADC) measurements of the normal liver parenchyma in breathhold, respiratory triggered, and free-breathing diffusion-weighted magnetic resonance imaging (DWI). Eleven healthy volunteers underwent three series of DWI. Each DWI series consisted of one breathhold, one respiratory triggered, and two free-breathing (thick and thin slice acquisition) scans of the liver, at b-values of 0 and 500 s/mm2. ADCs of the liver parenchyma were compared by using nonparametric tests. Reproducibility was assessed by the Bland-Altman method. Mean ADCs (in 10(-3) mm2/sec) in respiratory triggered DWI (2.07-2.27) were significantly higher than mean ADCs in breathhold DWI (1.57-1.62), thick slice free-breathing DWI (1.62-1.65), and thin slice free-breathing DWI (1.57-1.66) (P<0.005). Ranges of mean difference in ADC measurement+/-limits of agreement between two scans were -0.02-0.05+/-0.16-0.24 in breathhold DWI, -0.14-0.20+/-0.59-0.60 in respiratory triggered DWI, -0.03-0.03+/-0.20-0.29 in thick slice free-breathing DWI, and -0.01-0.09+/-0.21-0.29 in thin slice free-breathing DWI. ADC measurements of the normal liver parenchyma in respiratory triggered DWI are significantly higher and less reproducible than in breathhold and free-breathing DWI. Copyright (c) 2008 Wiley-Liss, Inc.
The Power of Ground User in Recommender Systems
Zhou, Yanbo; Lü, Linyuan; Liu, Weiping; Zhang, Jianlin
2013-01-01
Accuracy and diversity are two important aspects to evaluate the performance of recommender systems. Two diffusion-based methods were proposed respectively inspired by the mass diffusion (MD) and heat conduction (HC) processes on networks. It has been pointed out that MD has high recommendation accuracy yet low diversity, while HC succeeds in seeking out novel or niche items but with relatively low accuracy. The accuracy-diversity dilemma is a long-term challenge in recommender systems. To solve this problem, we introduced a background temperature by adding a ground user who connects to all the items in the user-item bipartite network. Performing the HC algorithm on the network with ground user (GHC), it showed that the accuracy can be largely improved while keeping the diversity. Furthermore, we proposed a weighted form of the ground user (WGHC) by assigning some weights to the newly added links between the ground user and the items. By turning the weight as a free parameter, an optimal value subject to the highest accuracy is obtained. Experimental results on three benchmark data sets showed that the WGHC outperforms the state-of-the-art method MD for both accuracy and diversity. PMID:23936380
Mürtz, Petra; Kaschner, Marius; Träber, Frank; Kukuk, Guido M; Büdenbender, Sarah M; Skowasch, Dirk; Gieseke, Jürgen; Schild, Hans H; Willinek, Winfried A
2012-11-01
To evaluate the use of dual-source parallel RF excitation (TX) for diffusion-weighted whole-body MRI with background body signal suppression (DWIBS) at 3.0 T. Forty consecutive patients were examined on a clinical 3.0-T MRI system using a diffusion-weighted (DW) spin-echo echo-planar imaging sequence with a combination of short TI inversion recovery and slice-selective gradient reversal fat suppression. DWIBS of the neck (n=5), thorax (n=8), abdomen (n=6) and pelvis (n=21) was performed both with TX (2:56 min) and with standard single-source RF excitation (4:37 min). The quality of DW images and reconstructed inverted maximum intensity projections was visually judged by two readers (blinded to acquisition technique). Signal homogeneity and fat suppression were scored as "improved", "equal", "worse" or "ambiguous". Moreover, the apparent diffusion coefficient (ADC) values were measured in muscles, urinary bladder, lymph nodes and lesions. By the use of TX, signal homogeneity was "improved" in 25/40 and "equal" in 15/40 cases. Fat suppression was "improved" in 17/40 and "equal" in 23/40 cases. These improvements were statistically significant (p<0.001, Wilcoxon signed-rank test). In five patients, fluid-related dielectric shading was present, which improved remarkably. The ADC values did not significantly differ for the two RF excitation methods (p=0.630 over all data, pairwise Student's t-test). Dual-source parallel RF excitation improved image quality of DWIBS at 3.0 T with respect to signal homogeneity and fat suppression, reduced scan time by approximately one-third, and did not influence the measured ADC values. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Malyarenko, Dariya I; Ross, Brian D; Chenevert, Thomas L
2014-03-01
Gradient nonlinearity of MRI systems leads to spatially dependent b-values and consequently high non-uniformity errors (10-20%) in apparent diffusion coefficient (ADC) measurements over clinically relevant field-of-views. This work seeks practical correction procedure that effectively reduces observed ADC bias for media of arbitrary anisotropy in the fewest measurements. All-inclusive bias analysis considers spatial and time-domain cross-terms for diffusion and imaging gradients. The proposed correction is based on rotation of the gradient nonlinearity tensor into the diffusion gradient frame where spatial bias of b-matrix can be approximated by its Euclidean norm. Correction efficiency of the proposed procedure is numerically evaluated for a range of model diffusion tensor anisotropies and orientations. Spatial dependence of nonlinearity correction terms accounts for the bulk (75-95%) of ADC bias for FA = 0.3-0.9. Residual ADC non-uniformity errors are amplified for anisotropic diffusion. This approximation obviates need for full diffusion tensor measurement and diagonalization to derive a corrected ADC. Practical scenarios are outlined for implementation of the correction on clinical MRI systems. The proposed simplified correction algorithm appears sufficient to control ADC non-uniformity errors in clinical studies using three orthogonal diffusion measurements. The most efficient reduction of ADC bias for anisotropic medium is achieved with non-lab-based diffusion gradients. Copyright © 2013 Wiley Periodicals, Inc.
Dimensionless, Scale Invariant, Edge Weight Metric for the Study of Complex Structural Networks
Colon-Perez, Luis M.; Spindler, Caitlin; Goicochea, Shelby; Triplett, William; Parekh, Mansi; Montie, Eric; Carney, Paul R.; Price, Catherine; Mareci, Thomas H.
2015-01-01
High spatial and angular resolution diffusion weighted imaging (DWI) with network analysis provides a unique framework for the study of brain structure in vivo. DWI-derived brain connectivity patterns are best characterized with graph theory using an edge weight to quantify the strength of white matter connections between gray matter nodes. Here a dimensionless, scale-invariant edge weight is introduced to measure node connectivity. This edge weight metric provides reasonable and consistent values over any size scale (e.g. rodents to humans) used to quantify the strength of connection. Firstly, simulations were used to assess the effects of tractography seed point density and random errors in the estimated fiber orientations; with sufficient signal-to-noise ratio (SNR), edge weight estimates improve as the seed density increases. Secondly to evaluate the application of the edge weight in the human brain, ten repeated measures of DWI in the same healthy human subject were analyzed. Mean edge weight values within the cingulum and corpus callosum were consistent and showed low variability. Thirdly, using excised rat brains to study the effects of spatial resolution, the weight of edges connecting major structures in the temporal lobe were used to characterize connectivity in this local network. The results indicate that with adequate resolution and SNR, connections between network nodes are characterized well by this edge weight metric. Therefore this new dimensionless, scale-invariant edge weight metric provides a robust measure of network connectivity that can be applied in any size regime. PMID:26173147
Dimensionless, Scale Invariant, Edge Weight Metric for the Study of Complex Structural Networks.
Colon-Perez, Luis M; Spindler, Caitlin; Goicochea, Shelby; Triplett, William; Parekh, Mansi; Montie, Eric; Carney, Paul R; Price, Catherine; Mareci, Thomas H
2015-01-01
High spatial and angular resolution diffusion weighted imaging (DWI) with network analysis provides a unique framework for the study of brain structure in vivo. DWI-derived brain connectivity patterns are best characterized with graph theory using an edge weight to quantify the strength of white matter connections between gray matter nodes. Here a dimensionless, scale-invariant edge weight is introduced to measure node connectivity. This edge weight metric provides reasonable and consistent values over any size scale (e.g. rodents to humans) used to quantify the strength of connection. Firstly, simulations were used to assess the effects of tractography seed point density and random errors in the estimated fiber orientations; with sufficient signal-to-noise ratio (SNR), edge weight estimates improve as the seed density increases. Secondly to evaluate the application of the edge weight in the human brain, ten repeated measures of DWI in the same healthy human subject were analyzed. Mean edge weight values within the cingulum and corpus callosum were consistent and showed low variability. Thirdly, using excised rat brains to study the effects of spatial resolution, the weight of edges connecting major structures in the temporal lobe were used to characterize connectivity in this local network. The results indicate that with adequate resolution and SNR, connections between network nodes are characterized well by this edge weight metric. Therefore this new dimensionless, scale-invariant edge weight metric provides a robust measure of network connectivity that can be applied in any size regime.
López-Larrubia, Pilar; Cauli, Omar
2011-03-15
Diffusion-weighted imaging (DWI) allows the assessment of the water apparent diffusion coefficient (ADC), a measure of tissue water diffusivity which is altered during different pathological conditions such as cerebral oedema. By means of DWI, we repeatedly measured in the same rats apparent diffusion coefficient ADC in different brain areas (motor cortex (MCx), somato-sensory cortex (SCx), caudate-putamen (CPu), hippocampus (Hip), mesencephalic reticular formation (RF), corpus callosum (CC) and cerebellum (Cb)) after 1 week, 4 and 12 weeks of lead acetate exposure via drinking water (50 or 500 ppm). After 12 weeks of lead exposure rats received albumin-Evans blue complex administration and were sacrificed 1h later. Blood-brain barrier permeability and water tissue content were determined in order to evaluate their relationship with ADC changes. Chronic exposure to lead acetate (500 ppm) for 4 weeks increased ADC values in Hip, RF and Cb but no in other brain areas. After 12 weeks of lead acetate exposure at 500 ppm ADC is significantly increased also in CPu and CC. Brain areas displaying high ADC values after lead exposure showed also an increased water content and increased BBB permeability to Evans blue-albumin complex. Exposure to 50 ppm for 12 weeks increased ADC values and BBB permeability in the RF and Cb. In summary, chronic lead exposure induces cerebral oedema in the adult brain depending on the brain area and the dose of exposure. RF and Cb appeared the most sensitive brain areas whereas cerebral cortex appears resistant to lead-induced cerebral oedema. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values.
Thörmer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe; Horn, Lars-Christian; Kahn, Thomas; Busse, Harald
2012-08-01
To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm(2)) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS= 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. • Absolute ADC values are highly dependent on the choice of b values. • Absolute ADC thresholds should be used carefully to predict tumour aggressiveness. • Subjective ratings of ADC maps involving b = 0 s/mm ( 2 ) are poor to fair. • Minimum b value greater than 0 s/mm ( 2 ) is recommended for ADC calculation.
Heusch, Philipp; Köhler, Jens; Wittsack, Hans-Joerg; Heusner, Till A; Buchbender, Christian; Poeppel, Thorsten D; Nensa, Felix; Wetter, Axel; Gauler, Thomas; Hartung, Verena; Lanzman, Rotem S
2013-11-01
To assess the feasibility of non-Gaussian DWI as part of a FDG-PET/MRI protocol in patients with histologically proven non-small cell lung cancer. 15 consecutive patients with histologically proven NSCLC (mean age 61 ± 11 years) were included in this study and underwent whole-body FDG-PET/MRI following whole-body FDG-PET/CT. As part of the whole-body FDG-PET/MRI protocol, an EPI-sequence with 5 b-values (0, 100, 500, 1000 and 2000 s/mm(2)) was acquired for DWI of the thorax during free-breathing. Volume of interest (VOI) measurements were performed to determine the maximum and mean standardized uptake value (SUV(max); SUV(mean)). A region of interest (ROI) was manually drawn around the tumor on b=0 images and then transferred to the corresponding parameter maps to assess ADC(mono), D(app) and K(app). To assess the goodness of the mathematical fit R(2) was calculated for monoexponential and non-Gaussian analysis. Spearman's correlation coefficients were calculated to compare SUV values and diffusion coefficients. A Student's t-test was performed to compare the monoexponential and non-Gaussian diffusion fitting (R(2)). T staging was equal between FDG-PET/CT and FDG-PET/MRI in 12 of 15 patients. For NSCLC, mean ADC(mono) was 2.11 ± 1.24 × 10(-3) mm(2)/s, Dapp was 2.46 ± 1.29 × 10(-3) mm(2)/s and mean Kapp was 0.70 ± 0.21. The non-Gaussian diffusion analysis (R(2)=0.98) provided a significantly better mathematical fitting to the DWI signal decay than the monoexponetial analysis (R(2)=0.96) (p<0.001). SUV(max) and SUV(mean) of NSCLC was 13.5 ± 7.6 and 7.9 ± 4.3 for FDG-PET/MRI. ADC(mono) as well as Dapp exhibited a significant inverse correlation with the SUV(max) (ADC(mono): R=-0.67; p<0.01; Dapp: R=-0.69; p<0.01) as well as with SUV(mean) assessed by FDG-PET/MRI (ADC(mono): R=-0.66; p<0.01; Dapp: R=-0.69; p<0.01). Furthermore, Kapp exhibited a significant correlation with SUV(max) (R=0.72; p<0.05) and SUV(mean) as assessed by FDG-PET/MRI (R=0.71; p<0.005). Simultaneous PET and non-Gaussian diffusion acquisitions are feasible. Non-Gaussian diffusion parameters show a good correlation with SUV and might provide additional information beyond monoexponential ADC, especially as non-Gaussian diffusion exhibits better mathematical fitting to the decay of the diffusion signal than monoexponential DWI. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Transition from compact to porous films in deposition with temperature-activated diffusion.
di Caprio, Dung; Aarão Reis, F D A
2015-07-01
We study a thin-film growth model with temperature activated diffusion of adsorbed particles, allowing for the formation of overhangs and pores, but without detachment of adatoms or clusters from the deposit. Simulations in one-dimensional substrates are performed for several values of the diffusion-to-deposition ratio R of adatoms with a single bond and of the detachment probability ε per additional nearest neighbor, respectively, with activation energies are E(s) and E(b). If R and ε independently vary, regimes of low and high porosity are separated at 0.075≤ε(c)≤0.09, with vanishingly small porosity below that point and finite porosity for larger ε. Alternatively, for fixed values of E(s) and E(b) and varying temperature, the porosity has a minimum at T(c), and a nontrivial regime in which it increases with temperature is observed above that point. This is related to the large mobility of adatoms, resembling features of equilibrium surface roughening. In this high-temperature region, the deposit has the structure of a critical percolation cluster due to the nondesorption. The pores are regions enclosed by blobs of the corresponding percolating backbone, thus the distribution of pore size s is expected to scale as s(-τ̃) with τ̃≈1.45, in reasonable agreement with numerical estimates. Roughening of the outer interface of the deposits suggests Villain-Lai-Das Sarma scaling below the transition. Above the transition, the roughness exponent α≈0.35 is consistent with the percolation backbone structure via the relation α=2-d(B), where d(B) is the backbone fractal dimension.